HomeMy WebLinkAbout17725 48TH DR NE_BLD20080112_2026 INSPECTION REPORT
• Permit No.: Zcx)'�' 7- Lot #:
Address: 1 7•)15 q 8 P:t rive
Contractor: 6)MIneLeted
• ♦ Owner: bn4i.r na ac
Date: 17-16- Og
❑ APPROVAL ❑ PARTIAL APPROVAL
❑ VIOLATION ❑ CORRECTION REQUESTED
❑ Corrections listed below MUST BE MADE before work can be approved.
❑ Please contact inspector.
❑ Was not able to perform inspection.
❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required.
e / i
/ E54 Is
Inspector: 7 Date: g A-08
TYPE OF INSPECTION REQUESTED
❑ Under-floor ❑ Framing ❑ Gas Piping
❑ Footing ❑ Drywall, Nailing ❑ Consultation
❑ Foundation ❑ Shear Nailing ❑ Groundwork
❑ Mechanical ❑ Grid ❑ Struct. Slab
❑ Wood Stove ❑ Rough-in ❑ Final
❑ Masonry ❑ Drainage ❑ Insulation
❑ Other:
� `-"
_��
� � � � � � :�
' � _ � :.
,�
II ��
- `� - _ � �
� - � � -
- - � �� - -
� � _
CITY OF ARLINGTON
238 N,OLYMPIC AVE.-ARLINGTON,WA.98223
PHONE:(360)403-3421
Permit#: BLD20080112
BUILDING .
Project Address: 17725 48TH DR, ARLINGTON
Parcel No:
PROPERTY OWNER APPLICANT CONTRACTOR
ARLINGTON AIRPORT PARTNERS LLP COMMERCIAL FIRE PROTECTION COMMERCIAL FIRE PROTECTION
17617 49T I PLACE NE PO BOX 128 PO BOX 128
ARLINGTON,WA 98223 MT.VERNON,WA 98273 MT.VERNON,WA 98273
Phone: Phone:360.848.9093 LICENSE#:COMMERFP132MM EXP:12/31/2008
Email: Email:dells cfire ro.coin
PLUM BING CONTRACTOR • '
Lie#. ExQ Lic#: Ex :
• C DESCRIPTION
INSTALLATION OF FIRE SPRINKLER SYSTEM IN ABBATARE HANGER#7
VALUATION: $35,000
PERMIT TYPE:Commercial PERMIT GROUP:Fire Sprinkler
NUMBER OF STORIES:0 TYPE OF CONSTRUCTION:
NUMBER OF DWELLING UNITS:0 OCCUPANT GROUP:
CODE:2006 OCCUPANT LOAD:
EXISTING AREA PRO POSE D,,k R EA
BASEMENT:0 1ST FLOOR:O 2ND FLOOR:0 I BASEMENT:0 1ST FLOOR:0 2ND FLOOR:0
3RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0 13RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0
FRONT SETBACK1SETBACK
REQUIRED: PROPOSED: RE UIRED: PROPOSED: RE UIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O RE UIRED: PROPOSED:
SETBACK NOTES:
PERMITAPPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27.
PPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
-Ad-V;� 5-+3-08 � S P OF
Si tur Print Name Date a ased By D e
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED.UBC 109/IBC 110/IRC 110.
ARCHIVE APPLICANT = ASSESSOR OTHER
BLD20080112
CONDITIONS
• None
PERMIT FEE,S
Description Fee Amount Paid Balance Due
C-Plumbing Permit Fee $0.00 $0.00 $0.00
C-Mechanical Permit Fee $0.00 $0.00 $0.00
C-Consultant(Fire/Sprinkler) $640.40 $0.00 $640.40
C-Building Plan Review Fee $382.36 $0.00 $382.36
Total Due: $1,022.76 $0.00 $1,022.76
INSPECTIONS
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE
PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
CALL FOR INSPEcTiONS
BUILDING/ENGINEERING/PARKS/UTILITIES/FINAL(360)435-0674
FIRE(360)403-3607
When calling for an inspection please leave the following information: Permit Number,Job Site Address,Type of Inspection
being requested,Contact Name and Phone Number.Date Prefereed,and whether you prefer morning or afternoon.
• None
BLD20080112 - arusko Page 1 of 1
BLD - Building Permit Ver: 2008A Priority: Jra-7 - #BLD20080112
owner: JARLINGTON AIRPORT PARTNERS LLP-A status: JAPPLIED
address: 117725 48TH DR, ARLINGTON post date: 4/30/2008
PERMITS data screens: Select Screen._ functions: Select Permit Function...
Fire Sprinkler
REVIEWS
Add Review Remove Review Print Close
Review Description Assigned To Due Date W) Req? Done? ASSIGN
1026 P-Utilities Fees RSHEPARD 5/13/2008 0 Y N I ASSIGN
1032 P-Utilities I LTAYLOR 5/13/2008 0 Y N 1 ASSIGN
2000 C-Building I CYCLING 5/13/2008 0 j Y N , ASSIGN
2008 C-Community Development I ARUSKO 5/13/20081 0 Y I N ASSIGN
3004 X-Fire TCOOPER 5/13/2008I 0 Y N ASSIGN
4000 0-Fire Consultant JTRACY 5/13/2008 0 Y 1 N ASSIGN
G
http://coaweb2.arlington.local/permittrax/PermitTraxMain/wfPermitConsoleReviews.aspx... 4/3 0/2008
C:
"" FIRE SPRINKLER
?� io PERMIT APPLICATION
•IN c Department of Community Development
City of Arlington•238 N Olympic Ave. •Arlington,WA 98223 • Phone (360)403 3431 • FAX(360)403 3447
THIS APPLICATION MUST BE ACCOMPANIED BY EIGHT(8) SETS OF COMPLETE AND SCALED PLANS, EIGHT
(8) SETS OF HYDRALIC CALCULATIONS, EIGHT(8) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE
SPRINKLER PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO INCLUDE
SPECIFICATION SHEETS, WIRING DIAGRAMS(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON
ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION.
Type of Permit: New Fire Sprinkler ( ) Fire Sprinkler Add/Alt ( ) Underground Fire 1,ine
Project Address: Parcel ID#
Project Va ation: Number of Heads: Building Area (Sq Ft):
A
Owner: ALti Phone Numbeer: (�QAddress: CilV�%
State: �L' Zip Code: "I[l 2�
Contact Person: / S AY \ Phone Number:l , kO V 40 10�c9�,��
Cell Phone: Fax:3UO U�10� QTQ E-mail: 0 C . Wf� '
Address _ 1 f1 ) City: State: Zip Code: 27 3
contractor:
Phone Number:
Address: `"'` ' City. State: Zip Code: q R 2?3
Contractor's License Number:`��I t� I J[ ," 1► ' 1 Expiration:
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
d d property will be i accordance with the laws,rules and regulation of the State ofWashington.
I l Mature ateY 1
Print Applicants Name
RECEIVE[
FOR STAFF USE ONLY APR 2 9 2008
dun 3D0 Af f COA PERMIT CENTER
"Permit# A, epted By Amount Received Receipt# Date Received
WEB Forms—24 Page 1 of 1 5/05 dwa
`'�Y. FIRE SPRINKLER
< PERMIT APPLICATION
7,r��N(,1�� Department of Community Development
City of Arlington • 238 N Olympic Ave. •Arlington,WA 98223 • Phone (360)403 3431 • FAX (360)403 3447
THIS APPLICATION MUST BE ACCOMPANIED BY EIGHT(8) SETS OF COMPLETE AND SCALED PLANS, EIGHT
(8) SETS OF HYDRALIC CALCULATIONS, EIGHT(8)SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE
SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO INCLUDE
SPECIFICATION SHEETS, WIRING DIAGRAMS(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON
ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION.
Type of Permit: New Fire Sprinkler ( ) Fire Sprinkler Add/Alt ( ) Underground Fire 4ine
Project Address. Parcel ID#
Project Va ation: 35 Number of Heads: Building Area(Sci Ft):
Owner: i2fiPhone Number:
t-
Address: � � n c� /�Cit State: Zip Code: J I
Contact Person: - 1`a )c \ `' Phone Number:-lQ0 800 9O9
Cell Phone: Fax:3W p �l/�O' of n� E-mail: 0 � �• ��
Address: n��5,,,1x I City:"i \I( r:Od State: Zip Code: 3
Contracto�r:j Irl �,o�y�r,�/ Phone Number: o � `f� �1 L%3
Address: �� �Z 1 Citty � t- l e IUt -) State: Zip Code: q " L 7 3
Contractor's License Number:�- mF' I -r�-��� Expiration:� � l_1
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
d d property will be i accordance with the laws, rules and regulation of the State of Washington
2� f
Ap licants Signature bate
Print Applicants Name
RECEIVED
FOR STAFF USE ONLY APR 2 9 2008
�c�$bIt___4- COA PERMIT CENTER
"Permit# Accepted By Amount Received Receipt# Date Received
WEB Forms—24 Page 1 of 1 5/05 dwa
Commercial Fire Protection Inc Transmittal
P. O. Box 128
17199 Bennett Road Date: 04-28-2008
Mt.Vernon WA 98273-9789
360 8•48-9093
License: COMMEFP 132 %1M
To: City of Arlington Project: 2008065
238 N Olympic Ave Abbatare Hangar 7
Arlington WA 98223 17725 48th Dr.
Arlington WA 98223
Prepared By: DELLA ANTSEN
Item Quantity Description
1 8 Plans& Calcs for Approval
2 8 Head& Backflow Submittal
3 1 Permit Application
Notes
Please sign and date this form as proof that you are in receipt of the above listed items.
Return form to Commercial Fire Protection Inc
Signed: _ Date:
May 5, 2008
TO: Scott Black
Department of Community Development
City of Arlington
Arlington, WA
FR: Jim Tracy
Code Consultant
Tracy III Enterprizes
Woodinville, WA
RE: ABBATARE Hanger#7
17725 48th Drive
Arlington, WA
Permit No. 20081002
PLAN REVIEW
AUTOMATIC SPRINKLER SYSTEM
We have reviewed the plans and calculations submitted by Commercial Fire Protection
Inc. of Mt. Vernon, WA.
The plan is approved subject to hydrostatic test, field inspection and the following:
1. Provide an exterior strobe in addition to the bell shown on the plan.
2. Proved a relief valve to the gridded automatic sprinkler system.
3. The system shall be monitored by a UL listed Central Station.
For inspections and tests, contact Jim Tracy at 206-940-9622.
l CUFF;'CE C ppy
.:
.;
. r
Abbatbxxe Hangar Bldg E Drawing Date: 4121108 10:53
HYDRAULIC DESIGN INFORMATION SHEET
Job Name: Abbatare Hangar Bldg E
Location: 17725 48th Dr.
Arlington, WA
Drawing Date: Remote Area Number: 2
Contractor: Commercial Fire Protection Inc. Telephone: 360-848-9093
PO Box 128
Mt Vernon, WA
Designer: kk
Calculated By:SprinkCAD
www.sprinkcad.com
451 N. Cannon Ave.
Lansdale, PA 19446
Construction: IIB Occupancy:S-1
Reviewing Authorities:City of Arlington
SYSTEM DESIGN
Code: 02 NFPA 13 Hazard:LH System Type:WET
Area of Sprinkler Oper. 1500 sq ft Sprinkler or Nozzle
Density (gpm/sq ft) 0 . 100 Make: TYCO
Area per Sprinkler 144. 0 sq ft Model : TY-FRB
Hose Allowance Inside 0 gpm K-Factor: 5 .60
Hose Allowance Outside 100 gpm Temperature Rating: 155
CALCULATION SUMMARY 6 Flowing Outlets
gpm Required: 230.3 psi Required: 72.4 @ CITY CONN
WATER SUPPLY
Water Flow Test Pump Data
Date of Test 2008 Rated Capacity 0 gpm
Static Pressure 94. 0 psi Rated Pressure 0 . 0 psi Ii
Residual Pries 20 . 0 psi ( Elevation 0
At a Flow of 4000 gpm I Make: li
Elevation 0" l+ Model :
Location: Airport Blvd
Source of Information: City of Arlington
SYSTEM VOLUME 394 Gallons
Notes:
lmd
RECEIVED
APR 2 9 2008
COA PERMIT CENTER1°"
� �,
I
I
I
I
Abbatarb Hangar Bldg E Drawing Date: 4121108 10:53
HYDRAULIC CALCULATION DETAILS
HYDRAULIC FLOW LOSS
QTY DESCRIPTION LENGTH C ID gpm psi TOTALS
Hydr Ref W Required at Hyd Area 2 130 66.9 psi
1 611 Grvd 90 Ell 14 ' 120 6 . 065 130 0.0
1 Pipe 6" 10x21 20 ' 120 6 .357 130 0.0
2 6" Grvd 90 Ell 28 ' 120 6. 065 130 0.0
Total Loss for TO SYSTEM 0.0 psi
1 6" Grvd Back Flow Valve Wilkins 1145 CHART LOSS 130 5.4
1 61, Fingd Gate Valve 11721U" PIV 3 ' 120 6 . 065 130 0. 0
Total Loss for THRU RISER 5.4 psi
Hydr Ref R1 Required at AT BASE OF RISER 130 72.3 psi
1 Pipe 12" DIx18 Cl 350 68 ' 140 12 .578 130 0.0
1 12" MJ Tee 60 ' 120 11. 938 130 0.0
1 12 Fingd Gate Valve 0 ' 0 11. 938 130 0.0
1 Pipe 8" DIx18 Cl 350 309 ' 140 12 .578 130 0.0
3 8" MJ Tee 105 ' 120 8 . 071 130 0.0
1 Pipe 6" DIx18 Cl 350 203 ' 140 12 .578 130 0.0
2 6" MJ Tee 60 ' 120 6 . 065 130 0. 1
1 6" Fingd Gate Valve 11721U" PIV 3 ' 120 6. 065 130 0.0
3 6" MJ 90 Ell 42 ' 120 6. 065 130 0.0
Fixed Flow Outside Hose Allow. 100 gpm
Total Loss for THRU UNDG 0.1 psi
Hydr Ref R2 Required at CITY CONN 230 72.4 psi
Water Source 94. 0 psi static, 20 . 0 psi residual @ 4000 gpm 230 gpm 93.6 psi
SAFETY PRESSURE 21.2 psi
Available Pressure of 93.6 psi Exceeds Required Pressure of 72.4 psi
This is a safety margin of 21.2 psi or 23 % of Supply
Maximum Water Velocity is 26 .7 fps
I
I
Abbatare Hangar Bldg E Drawing Date: 4121108 10:53
Page 3
FITTING NAME TABLE
ABBREV. NAME
C Coupling
E 90 ' Standard Elbow
F 45' Elbow
S Straight Flow Thru Tee
T 90 ' Flow Thru Tee
V Valve
LEGEND
HYD REF Hydraulic reference. Refer to accompanying flow diagram. _
K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P
Qa Flow added or subtracted
Qt Total flow
DIA Actual internal diameter of pipe
C Hazen Williams pipe roughness factor
Pf/ft Friction loss per foot of pipe
PIPE Length of pipe
FTNGIS Number of fittings. See table above.
TOTAL Total length (PIPE + FTNG'S)
Pt Total pressure (psi) at fitting
Pe Pressure due to change in elevation
where Pe = 0 .433 x change in elevation
Pf Friction loss (psi) to fitting
where Pf = 1 x 4 .52 x (Q/C) A1. 85 / IDA4 . 87
Pv Velocity pressure (psi)
where Pv = 0 . 001123 x QA2/IDA4
Pn Normal pressure (psi) , where Pn = Pt - Pv
NOTES:
- Pressures are balanced to 0 . 01 psi. Pressures are listed to
0 . 1 psi. Addition may vary by 0. 1 psi due to accumulation of
round off.
- Calculations conform to NFPA 13 .
- Velocity Pressures are not considered in these Calculations
i
Abbatare hangar Bldg E Drawing Date: 4121108 10:53
Page 4
NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL
NUMBER K-FACTOR FLOW FLOW DENSITY
(FT) (GPM/ (PSIAIA) ) (PSI) (GPM) (GPM) (GPM/SQ.FT)
1 20.77 58 . 9
2 21.40 58 . 7
3 22 . 02 58 .4
4 22. 65 58 . 1
5 23 .27 57. 9
6 23 . 90 57 . 6
7 24.52 57 .4
8 24.52 57 .4
17 20. 77 58 . 9
18 21.40 58 . 6
19 22 . 02 58 .4
30 7. 58 5 .60 17 . 5 23 .4 14. 8 0 . 16
31 7. 58 5. 60 27. 9 29. 6 14 . 8 0 .62
32 7.58 5 . 60 27 . 9 29.6 14 . 8 0.62
33 8 . 50 10 .3
33S 8. 33 5 . 60 9. 8 17.5 14 . 8 0.12
34 8. 50 7 . 9
34S 8 . 33 5 . 60 7. 6 15.4 14 . 8 0.17
35 8. 50 7 . 1
35S 8 .33 5. 60 7 . 0 14.8 14. 8 0 . 16
40 24. 52 57.4
41 24 . 52 57 .3
42 23 . 90 57 . 6
43 23 . 27 57. 9
44 22 . 65 58 . 1
45 22 . 02 58 .4
46 21 .40 58 . 7
47 20 . 77 58 . 9
48 21. 06 57 . 7
49 20 .25 58 . 1
50 8 . 50 17. 7
51 7 . 58 17. 6
52 7 . 58 29.3
Al 19 . 86 59.5
A2 19 . 86 59. 5
A3 19. 86 59. 5
A4 19 . 86 59 . 5
A5 19 . 86 59. 5
A6 19 . 86 59.5
A7 19 . 86 59. 5
A8 19. 86 59. 5
B1 19 . 90 59. 3
B2 19 . 90 59.2
B3 19 . 90 59 . 1
B4 19 . 90 58 . 6
B5 19 . 90 59. 0
B6 19 . 90 59. 1
W 3 . 00 66. 9
Max velocity of 26 . 70 occurs in the pipe from 50 TO 49
Nodes with "S" indicate a node at the top of a sprig or bottom
of drop pendent . The node without an "S" is on the branch.
i
Abbatare Hangar Bldg E Drawing Date: 4121108 10:53
Tyco Fire Products Page 5
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 1 FROM HYDRAULIC REFERENCE 35 TO W (PRIMARY PATH)
14 . 82 1. 049 lE 0 .17 7. 0 7. 0 K = 5 .60
35S C=120 2 . 00 -0 . 1 0 . 0
14 . 82 0 . 075 2 . 17 0 .2 7 . 0 Vel = 5 .55
1. 049 11.42 7. 1 7. 1 EqK = 5 .56
35 C=120 0 . 00 0 . 0 0 . 0
14 . 82 0 . 075 11.42 0 . 9 7. 1 Vel = 5 .55
15 .44 1. 049 8 .33 7. 9 7 .9 EqK = 5 .48
34 C=120 0. 00 0 . 0 0 . 0
30 .25 0 .280 8 .33 2 .3 7. 9 Vel = 11.34
17 . 55 1. 049 1T 6.33 10. 3 10 .3 EqK = 5 .47
33 C=120 5 . 00 0. 0 0 . 0
47 .80 0.652 11.33 7.4 10 .3 Vel = 17.92
23 .43 1. 049 4E 20 .40 17. 7 17. 7
50 C=120 1T 13 . 00 -5. 1 0 . 0 See PATH 2
71.23 1.364 33 .40 45. 6 17 . 7 Vel = 26.70
24 . 93 2 .157 4 . 16 58 . 1 58 . 1
49 C=120 0. 00 0 . 1 0 . 0 See PATH 5
96 . 15 0 . 071 4 . 16 0.3 58 . 1 Vel = 8 .52
-46 . 62 2 . 157 1T 12 .50 58 . 6 58 .6
B4 C=120 12 .31 0. 0 0 . 0 See PATH 6
49.54 0. 021 24 .81 0 .5 58 .6 Vel = 4.39
-15. 84 2 . 157 12 . 50 59. 1 59. 1
B3 C=120 0. 00 0. 0 0 . 0 See PATH 8
33 .69 0 . 010 12 . 50 0. 1 59. 1 Vel = 2 . 99
-12 .53 2 . 157 12 . 96 59.2 59.2
B2 C=120 0 . 00 0 . 0 0 . 0 See PATH 10
21 . 16 0 . 004 12 . 96 0 . 1 59.2 Vel = 1.88
-10.35 2 . 157 1T 10 .48 59 .3 59.3
B1 C=120 12 .31 -0 .4 0 . 0 See PATH 11
10.81 0 . 001 22 . 78 0 . 0 59 .3 Vel = 0.96
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
t
I
Abbatare Hangar Bldg E Drawing Date: 4121108 10:53
Tyco Fire Products Page 6
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 1 FROM HYDRAULIC REFERENCE 35 TO W (PRIMARY PATH)
2 . 157 7 .54 58 . 9 58 . 9
47 C=120 0 . 00 -0 .3 0 . 0
10 . 81 0 . 001 7 . 54 0 . 0 58 . 9 Vel = 0.96
2 . 157 7 .54 58 .7 58 . 7
46 C=120 0 . 00 -0 .3 0 . 0
10 .81 0 . 001 7 .54 0. 0 58. 7 Vel = 0.96
2 . 157 7.54 58 .4 58 .4
45 C=120 0 . 00 -0.3 0 . 0
10 . 81 0 . 001 7 . 54 0. 0 58 .4 Vel = 0. 96
2 . 157 7 .54 58. 1 58 . 1
44 C=120 0 . 00 -0 .3 0 . 0
10 . 81 0 . 001 7 . 54 0 .0 58 . 1 Vel 0. 96
2 . 157 7 .54 57.9 57. 9
43 C=120 0 . 00 -0 .3 0 .0
10 . 81 0 . 001 7 .54 0. 0 57. 9 Vel = 0.96
2 . 157 7 .54 57. 6 57 . 6
42 C=120 0 . 00 -0 .3 0 . 0
10 . 81 0 . 001 7 .54 0. 0 57. 6 Vel = 0. 96
2 . 157 7 .54 57.3 57.3
41 C=120 0 . 00 0 . 0 0 . 0
10 . 81 0 . 001 7 . 54 0. 0 57.3 Vel = 0. 96
2 . 157 1T 56 .23 57.4 57 .4
40 C=120 12 .31 2. 0 0 . 0
10 . 81 0 . 001 68 .53 0. 1 57.4 Vel = 0. 96
10 .35 6 .357 12 . 96 59. 5 59.5
A2 C=120 0 . 00 0. 0 0 . 0 See PATH 11
21. 16 0 . 000 12 . 96 0. 0 59.5 Vel = 0. 22
12 .53 6 . 357 12 .50 59.5 59.5
A3 C=120 0 . 00 0 . 0 0. 0 See PATH 10
33 . 69 0 . 000 12 . 50 0 . 0 59.5 Vel = 0. 34
15 . 84 6 . 357 12 . 50 59.5 59.5
A4 C=120 0 . 00 0. 0 0 . 0 See PATH 8
49. 54 0 . 000 12 . 50 0. 0 59.5 Vel = 0. 51
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
I
I
Abbatare Hangar Bldg E Drawing Date: 4121108 10:53
Tyco Fire Products Page 7
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 1 FROM HYDRAULIC REFERENCE 35 TO W (PRIMARY PATH)
34 . 19 6.357 12 .50 59. 5 59.5
A5 C=120 0 . 00 0. 0 0 . 0 See PATH 3
83 . 73 0 . 000 12 .50 0. 0 59.5 Vel = 0 . 85
17 .20 6.357 12 . 83 59. 5 59. 5
A6 C=120 0 . 00 0 . 0 0 . 0 See PATH 7
100 . 93 0. 000 12 .83 0. 0 59.5 Vel = 1. 03
14 . 95 6.357 12 . 17 59. 5 59.5
A7 C=120 0. 00 0. 0 0 . 0 See PATH 6
115 . 88 0. 001 12 . 17 0 . 0 59.5 Vel = 1. 18
14 . 46 6.357 3E 27.94 59. 5 59. 5
A8 C=120 52 . 81 7. 3 0. 0 See PATH 9
130 . 34 0. 001 80 .75 0 . 1 59.5 Vel = 1.33
W 130 .34 66 . 9 K = 15. 94
15 .44 1. 049 1T 0 . 17 7 . 6 7. 6 K = 5. 60
34S C=120 5. 00 -0. 1 0. 0
15 .44 0. 081 5. 17 0 .4 7.6 Vel = 5. 79
34 15 .44 7. 9 K = 5.48
17 . 55 1. 049 1T 0. 17 9. 8 9. 8 K = 5. 60
33S C=120 5. 00 . 0 . 1 0 . 0
17. 55 0 . 102 5. 17 0 . 5 9. 8 Vel = 6. 58
33 17 . 55 10 . 3 K = 5. 47
PATH 2 FROM HYDRAULIC REFERENCE 30 TO 50
23 .43 1. 049 0.33 17. 5 17.5 K W 5. 60
30 C=120 0 . 00 0. 0 0 . 0
23 .43 0 . 174 0 .33 0 . 1 17.5 Vel = 8. 78
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
�i
�s_
I
Abbatare Hangar Bldg E Drawing Date: 4121108 10:53
Tyco Fire Products Page 8
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 2 FROM HYDRAULIC REFERENCE 30 TO 50 CONTINUED
1. 049 lE 0 . 92 17. 6 17 .6
51 C=120 2 . 00 -0 .4 0.0
23 .43 0 . 174 2 . 92 0 . 5 17. 6 Vel = 8. 78
50 23 .43 17 . 7 K _ 5. 57
PATH 3 FROM HYDRAULIC REFERENCE 32 TO A5
29. 56 1. 049 1T 0 .33 27. 9 27 . 9 K = 5. 60
32 C=120 5 . 00 0. 0 0. 0
29 . 56 0 .268 5 .33 1 . 4 27. 9 Vel = 11. 08
29. 56 1. 049 4E 22 .46 29.3 29.3
52 C=120 1T 13 . 00 -5 . 8 0. 0 See PATH 4
59. 12 0 . 966 35 .46 34 . 3 29.3 Vel = 22. 16
-24 . 93 2 .157 1T 105.47 57 . 7 57 .7
48 C=120 12 .31 0 . 5 0.0 See PATH 5
34 . 19 0 . 010 117. 77 1.2 57. 7 Vel = 3 . 03
A5 34 . 19 59. 5 K = 4. 43
PATH 4 FROM HYDRAULIC REFERENCE 31 TO 52
29 . 56 1. 049 1T 0 .33 27. 9 27. 9 K = 5. 60
31 C=120 5 . 00 0. 0 0 . 0
29. 56 0 .268 5 .33 1.4 27.9 Vel = 11. 08
52 29. 56 29 .3 K = 5. 46
PATH 5 FROM HYDRAULIC REFERENCE 48 TO 49
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
Abbatar�? Hangar Bldg E Drawing Date: 412110E 10:53
Tyco Fire Products Page 9
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 5 FROM HYDRAULIC REFERENCE 48 TO 49 CONTINUED
24 . 93 2 . 157 9. 87 57.7 57. 7
48 C=120 0 . 00 0.4 0 . 0 See PATH 3
24 . 93 0 . 006 9. 87 0. 1 57 . 7 Vel = 2. 21
49 24 . 93 58 .1 K = 3 . 27
PATH 6 FROM HYDRAULIC REFERENCE B4 TO A7
46. 62 2 . 157 1T 12 .50 58 . 6 58 . 6
E4 C=120 12 .31 0. 0 0 . 0 See PATH 1
46. 62 0 . 019 24 . 81 0.5 58 . 6 Vel = 4. 13
-17 .20 2 . 157 12 . 83 59. 0 59. 0
B5 C=120 0 . 00 0. 0 0 . 0 See PATH 7
29.42 0 . 008 12 . 83 0. 1 59 . 0 Vel = 2. 61
-14 .46 2 . 157 2T 119.49 59.1 59 . 1
B6 C=120 24 .61 0 . 0 0 . 0 See PATH 9
14 . 95 0 . 002 144 . 10 0 .3 59. 1 Vel = 1. 33
A7 14 . 95 59.5 K = 1. 94
PATH 7 FROM HYDRAULIC REFERENCE B5 TO A6
17 .20 2 . 157 2T 119.49 59. 0 59 . 0
B5 C=120 24 . 61 0 . 0 0 . 0 See PATH 6
17 .20 0 . 003 144. 10 0.4 59 . 0 Vel = 1. 53
A6 17 .20 59.5 K = 2. 23
PATH 8 FROM HYDRAULIC REFERENCE B3 TO A4
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
u
J
Abbatare Hangar Bldg E Drawing Date: 4121108 10:53
Tyco Fire Products Page 10
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 8 FROM HYDRAULIC REFERENCE B3 TO A4 CONTINUED
15 .84 2 . 157 2T 119.49 59. 1 59. 1
B3 C=120 24 . 61 0 . 0 0. 0 See PATH 1
15 .84 0 . 003 144 . 10 0 .4 59. 1 Vel = 1.40
A4 15 . 84 59 .5 K = 2 . 05
PATH 9 FROM HYDRAULIC REFERENCE B6 TO A8
14 .46 2 . 157 2T 131.66 59.1 59. 1
B6 C=120 24 . 61 0.0 0. 0 See PATH 6
14 .46 0 . 002 156.27 0.3 59 . 1 Vel = 1.28
A8 14 .46 59.5 K = 1.88
PATH 10 FROM HYDRAULIC REFERENCE B2 TO A3
12 . 53 2 . 157 1T 10 .48 59 .2 59.2
B2 C=120 12 .31 -0 .4 0 . 0 See PATH 1
12 .53 0. 002 22 . 78 0 . 0 59.2 Vel = 1. 11
2 . 157 7. 54 58 . 9 58 . 9
17 C=120 0 . 00 -0 .3 0 . 0
12 . 53 0 . 002 7 . 54 0 . 0 58 . 9 Vel = 1.11
2 . 157 7. 54 58 .6 58 . 6
18 C=120 0 . 00 -0 .3 0 . 0
12 .53 0 . 002 7 . 54 0 .0 58 . 6 Vel = 1. 11
2 . 157 1T 93 . 93 58 .4 58 .4
19 C=120 12 .31 0 . 9 0 . 0
12 . 53 0 . 002 106 . 24 0 .2 58 .4 Vel = 1. 11
A3 12 . 53 59.5 K = 1. 62
PATH 11 FROM HYDRAULIC REFERENCE B1 TO A2
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
r
I
I
I
AbbatarL, Hangar Bldg E Drawing Date: 4121108 10:53
Tyco Fire Products Page 11
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 11 FROM HYDRAULIC REFERENCE B1 TO A2 CONTINUED
10 .35 2 . 157 1T 22 . 64 59.3 59.3
Bl C=120 12 .31 -0 .4 0 . 0 See PATH 1
10 .35 0. 001 34. 95 0 . 0 59.3 Vel = 0 .92
2 . 157 7.54 58.9 58 . 9
1 C=120 0 . 00 -0.3 0 . 0
10 .35 0. 001 7.54 0. 0 58. 9 Vel = 0 .92
2 . 157 7 . 54 58 . 7 58. 7
2 C=120 0. 00 -0 .3 0 . 0
10 .35 0 . 001 7.54 0 . 0 58. 7 Vel = 0 .92
2 . 157 7.54 58.4 58.4
3 C=120 0 . 00 -0 .3 0. 0
10 .35 0 .001 7 . 54 0 . 0 58 .4 Vel = 0 .92
2 . 157 7.54 58 . 1 58 . 1
4 C=120 0 . 00 -0 . 3 0 . 0
10 . 35 0 . 001 7 .54 0 . 0 58. 1 Vel = 0 .92
2 . 157 7 . 54 57. 9 57. 9
5 C=120 0 . 00 -0 .3 0 . 0
10 .35 0 . 001 7.54 0 . 0 57. 9 Vel = 0 .92
2 . 157 7 .54 57.6 57 . 6
6 C=120 0 . 00 -0 .3 0 . 0
10 . 35 0. 001 7 . 54 0 . 0 57 . 6 Vel = 0 .92
2 . 157 7 .54 57 .4 57.4
7 C=120 0 . 00 0 . 0 0. 0
10 .35 0. 001 7 . 54 0 . 0 57.4 Vel = 0 .92
2 . 157 1T 56.23 57.4 57.4
8 C=120 12 .31 2.0 0. 0
10 . 35 0 . 001 68 . 53 0.1 57.4 Vel = 0 .92
6 .357 12 . 17 59.5 59.5
Al C=120 0 . 00 0. 0 0. 0
10 .35 0 . 000 12 . 17 0. 0 59.5 Vel = 0 .11
A2 10 . 35 59.5 K = 1 .34
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
I
b
\
/ / C)
00
2
/ f
E E .
co kkkaa 2
,It oogn n
/ R Ci
CN
m
k k
/ E +
� —
U
E \ \m §
CLmnml /
_ E
�
.Ek
RRo
7 % 7
) \
/ 3 /
3 § /
) a \ p
C § \ :
2 = . <
I F a k Q o
/ƒ ƒ 3 � / \
E
± � k
51 10
% C-4
/2 « e —
I =
a)co k \
cu
Cl?/ - sE
= ¥ — m
< � k ±
? k / 2 2 9 0
I
I
1
Ahdata?e Hangar Bldg E Drawing Date: 4125108 8:13
HYDRAULIC DESIGN INFORMATION SHEET
Job Name: Abbatare Hangar Bldg E
Location: 17725 48th Dr.
Arlington, WA
Drawing Date: Remote Area Number: 1
Contractor: Commercial Fire Protection Inc. Telephone:360-848-9093
PO Box 128
Mt Vernon, WA
Designer: kk
Calculated By:SprinkCAD
www.sprinkcad.com
451 N. Cannon Ave.
Lansdale, PA 19446
Construction: IIB Occupancy:S-1 ,
Reviewing Authorities:City of Arlington
SYSTEM DESIGN
Code: 02 NFPA13 Ha-zard:EH GRP 2 System Type:WET
Area of Sprinkler Oper. 2000 sq ft � Sprinkler or Nozzle
Density (gpm/sq ft) 0`.400 1 Make: TYCO
Area per Sprinkler 94 . 0 sq ftj Model : EL0231B
Hose Allowance Inside 0 gpm K-Factor: 11.20
Hose Allowance Outside 500 gpm I Temperature Rating: 286
CALCULATION SUMMARY 22 Flowing Outlets
gpm Required: 1423 .0 psi Required: 61.8 @ CITY CONN
WATER SUPPLY
Water Flow Test Pump Data
Date of Test 2008 Rated Capacity 0 gpm
Static Pressure 94 . 0 psi Rated Pressure 0 . 0 psi
Residual Pres 20 . 0 psi Elevation 0
At a Flow of 4000 gpm I Make:
Elevation 0" Model:
Location: Airport Blvd
Source of Information: City of Arlington
SYSTEM VOLUME 394 Gallons
Notes: /
i
,i
V
� 3i91tuw--07-1 65
RECEIVED
APR 2 9 2008
4_Z - o COA PERMIT CENTER
SLR 2bvg 611 a-
•
A ,
1
,' V
I
1 I
I
Abbatar2 Hangar Bldg E Drawing Date: 4125108 8:13
HYDRAULIC CALCULATION DETAILS
HYDRAULIC FLOW LOSS
QTY DESCRIPTION LENGTH C ID gpm psi TOTALS
Hydr Ref W Required at Hyd Area 1 923 50.4 psi
1 6" Grvd 90 Ell 14 ' 120 6. 065 923 0.4
1 Pipe 6" 10x21 20 ' 120 6.357 923 0.5
2 6" Grvd 90 Ell 28 ' 120 6. 065 923 0. 9
Total Loss for TO SYSTEM 1.8 psi
1 6" Grvd Back Flow Valve Wilkins 1145 CHART LOSS 923 4. 8
1 6" Fingd Gate Valve 11721U" PIV 3 ' 120 6. 065 923 0 . 1
Total Loss for THRU RISER 4.9 psi
Hydr Ref R1 Required at AT BASE OF RISER 923 57.2 psi
1 Pipe 12" DIx18 Cl 350 68 ' 140 12 .578 923 0. 0
1 12" MJ Tee 60 ' 120 11. 938 923 0. 1
1 12 Fingd Gate Valve 0 ' 0 11. 938 923 0. 0
1 Pipe 8" DIx18 Cl 350 309 ' 140 12 .578 923 0.2
3 8" MJ Tee 105 ' 120 8 . 071 923 0. 8
1 Pipe 6" DIx18 Cl 350 203 ' 140 12 .578 923 0. 1
2 6" MJ Tee 60 ' 120 6. 065 923 1. 9
1 6" Fingd Gate Valve 11721U" PIV 3 ' 120 6.065 923 0. 1
3 6" MJ 90 Ell 42 ' 120 6 . 065 923 1.3
Fixed Flow Outside Hose Allow. , 500 gpm
Total Loss for THRU UNDG 4.6 psi
Hydr Ref R2 Required at CITY CONN 1423 61.8 psi
Water Source 94 . 0 psi static, 20 . 0 psi residual @ 4000 gpm 1423 gpm 83 .1 psi
SAFETY PRESSURE 21.3 psi
Available Pressure of 83.1 psi Exceeds Required Pressure of 61.8 psi
This is a safety margin of 21.3 psi or 26 % of Supply
Maximum Water Velocity is 27 .3 fps
"+: .,
I
I
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Page 3
FITTING NAME TABLE
ABBREV. NAME
C Coupling
E 90 ' Standard Elbow
F 45 ' Elbow
S Straight Flow Thru Tee
T 90 ' Flow Thru Tee
V Valve
LEGEND
HYD REF Hydraulic reference. Refer to accompanying flow diagram. _
K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P
Qa Flow added or subtracted
Qt Total flow
DIA Actual internal diameter of pipe
C Hazen Williams pipe roughness factor
Pf/ft Friction loss per foot of pipe
PIPE Length of pipe .
FTNG'S Number of fittings. See table above.
TOTAL Total length (PIPE + FTNG' S)
Pt Total pressure (psi) at fitting
Pe Pressure due to change in elevation
where Pe = 0 .433 x change in elevation
Pf Friction loss (psi) to fitting
where Pf = 1 x 4 . 52 x (Q/C) A1. 85 / IDA4 . 87
Pv Velocity pressure (psi)
where Pv = 0 . 001123 x QA2/IDA4
Pn Normal pressure (psi) , where Pn = Pt - Pv
NOTES:
- Pressures are balanced to 0 . 01 psi . Pressures are listed to
0 . 1 psi . Addition may vary by 0 . 1 psi due to accumulation of
round off.
- Calculations conform to NFPA 13 .
- Velocity Pressures are not considered in these Calculations
I
i
i
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Page 4
NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL
NUMBER K-FACTOR FLOW FLOW DENSITY
(FT) (GPM/ (PSIA%) ) (PSI) (GPM) (GPM) (GPM/SQ.FT)
1 20 . 77 11.20 13 .5 41. 1 37 . 5 0 .44
2 21.40 11. 20 12 . 8 40. 0 37. 5 0 .43
3 22 . 02 11.20 12 .4 39.4 37 .5 0 .42
4 22 . 65 11.20 12 . 1 38 . 9 37 .5 0 .42
5 23 .27 11.20 11. 9 38 . 6 37 . 5 0 .41
6 23 . 90 11.20 11. 9 38 . 7 37.5 0 .41
7 24 .52 11.20 12 .3 39.3 37 . 5 0 .42
8 24 .52 11.20 13 .5 41.2 37 . 5 0 .44
9 23 . 90 11.20 15. 7 44 .4 37. 6 0.47
10 20 .77 11.20 12 . 6 39. 7 37 . 6 0 .42
11 21.40 11.20 12 .0 38 .8 37. 6 0 .41
12 22 . 02 11.20 11. 7 38 .3 37. 6 0.41
13 22 .65 11.20 11 .4 37. 9 37 . 6 0 .40
14 23 .27 11.20 11.3 37. 6 37. 6 0 .40
15 23 . 90 11.20 11 .3 37.6 37 . 6 0 .40
16 24 .52 11.20 11. 6 38 .2 37 . 6 0 .41
17 24 .52 11.20 12 .6 39.7 37 . 6 0 .42
18 23 . 90 11.20 14 .3 42 .4 37. 6 0 .45
19 20 . 77 11.20 22 .4 53 . 0 37 .6 0 .56
20 21.40 11.20 22 . 1 52 . 7 37 . 6 0 . 56
21 22 . 02 11.20 22 . 0 52 .5 37 . 6 0 . 56
22 22 . 65 11.20 22 .3 52 . 9 37 . 6 0 .56
40 23 . 90 17 . 1
41 24 . 52 15. 0
42 24 .52 13 . 9
43 23 . 90 13 .5
44 23 .27 13 .5
45 22 . 65 13 . 7
46 22 . 02 14. 0
47 21.40 14 .4
48 20 . 77 15. 1
49 21 . 06 35. 6
50 20 .25 35 . 6
Al 19 . 86 40. 0
A2 19. 86 40 . 0
A3 19 . 86 40. 1
A4 19. 86 40 .3
A5 19. 86 40 .4
A6 19 . 86 40 . 7
A7 19 . 86 40 . 9
A8 19 . 86 41.2
B1 19. 90 18 . 0
B2 19. 90 23 .4
B3 19 . 90 31. 1
B4 19. 90 35 . 1
B5 19. 90 37 . 1
36 19. 90 38 . 1
W 3 . 00 50 .4
Max velocity of 27 .34 occurs in the pipe from B2 TO B3
,�
I
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 5
HYD. Qa DIA. FITTING PIPE Pt Pt
REF ITC" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 1 FROM HYDRAULIC REFERENCE 12 TO W (PRIMARY PATH)
38 . 27 1. 049 1T 0 .33 11. 7 11. 7 K = 11.20
12 C=120 5 . 00 0. 0 0 . 0
38 . 27 0 .432 5 .33 2 .3 11 . 7 Vel = 14.35
6 . 54 2 . 157 7 .54 14 . 0 14 . 0
46 C=120 0 . 00 0. 3 0 . 0 See PATH 14
44 . 81 0 . 017 7. 54 0 . 1 14 . 0 Vel = 3 . 97
38 . 82 2 . 157 7.54 14 . 4 14 .4
47 C=120 0 . 00 0 . 3 0 . 0 See PATH 3
83 . 63 0 . 055 7 .54 0 . 4 14.4 Vel = 7.41
39 . 75 2 . 157 1T 10 .48 15. 1 15 . 1
48 C=120 12 .31 0 .4 0 . 0 See PATH 5
123 . 38 0 . 113 22 . 78 2 . 6 15 . 1 Vel = 10 . 94
127 . 06 2 . 157 12 . 96 18 . 0 18 . 0
B1 C=120 0 . 00 0 . 0 0 . 0 See PATH 8
250 .44 0 .417 12 . 96 5 . 4 18 . 0 Vel = 22 .20
57 . 94 2 .157 12 . 50 23 . 4 23 .4
B2 C=120 0. 00 0 . 0 0. 0 See PATH 13
308 .37 0 .613 12 . 50 7 . 7 23 .4 Vel = 27 .34
-90 .57 2 . 157 12 . 50 31. 1 31. 1
B3 C=120 0 . 00 0 . 0 0 . 0 See PATH 15
217 .80 0 .322 12 . 50 4 . 0 31. 1 Vel = 19.31
-67 .49 2 . 157 12 . 50 35 . 1 35 . 1
B4 C=120 0 . 00 0 . 0 0 . 0 See PATH 16
150 .31 0 .162 12 .50 2 . 0 35. 1 Vel = 13 .33
-53 . 88 2 . 157 12 . 83 37. 1 37 . 1
135 C=120 0 . 00 0 . 0 0 . 0 See PATH 17
96 .42 0 . 071 12 . 83 0. 9 37 . 1 Vel = 8 .55
-48 . 10 2 . 157 2T 131. 66 38 . 1 38 . 1
B6 C=120 24. 61 0. 0 0 . 0 See PATH 18
48 .32 0 .020 156.27 3 . 1 38 . 1 Vel = 4.28
874 . 69 6 .357 3E 27. 94 41. 2 41.2
A8 C=120 52. 81 7.3 0. 0 See PATH 2
923 .01 0 . 024 80. 75 1. 9 41.2 Vel = 9.42
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
I
i
u J
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 6
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
W 923 . 01 50 .4 K = 129. 96
PATH 2 FROM HYDRAULIC REFERENCE 13 TO A8
37 . 89 1 . 049 1T 0 .33 11.4 11.4 K = 11. 20
13 C=120 5 . 00 0 . 0 0. 0
37 . 89 0 .424 5 .33 2 .3 11.4 Vel = 14. 20
-6 . 54 2 . 157 7 . 54 13 . 7 13 . 7
45 C=120 0 . 00 -0 .3 0. 0 See PATH 14
31 .35 0 . 009 7 . 54 0 . 1 13 .7 Vel = 2. 78
37 . 60 2 . 157 7.54 13 .5 13 . 5
44 C=120 0 . 00 -0 .3 0 . 0 See PATH 4
68 . 95 0 . 038 7.54 0 .3 13 .5 Vel = 6. 11
37 . 63 2 . 157 7.54 13 . 5 13 . 5
43 C=120 0 . 00 -0 .3 0 . 0 See PATH 6
106 .57 0 . 086 7 .54 0 . 6 13 .5 Vel = 9.45
38 . 15 2 . 157 7.54 13 . 9 13 . 9
42 C=120 0 . 00 0. 0 0 . 0 See PATH 9
144 .73 0 . 151 7 . 54 1. 1 13 . 9 Vel = 12 . 83
39 .71 2 . 157 7 . 54 15. 0 15. 0
41 C=120 0 . 00 0.3 0 . 0 See PATH 10
184 .43 0 .237 7.54 1. 8 15 . 0 Vel = 16. 35
42 .37 2 . 157 1T 48 . 69 17 . 1 17. 1
40 C=120 12 .31 1. 7 0 . 0 See PATH 11
226 . 80 0 .347 60 . 99 21. 2 17 . 1 Vel = 20. 11
234 . 62 6 .357 12 . 96 40. 0 40. 0
A2 C=120 0 . 00 0. 0 0. 0 See PATH 7
461 .42 0 . 007 12 . 96 0. 1 40 . 0 Vel = 4 . 71
153 .22 6 .357 12 . 50 40. 1 40. 1
A3 C=120 0 . 00 0. 0 0 . 0 See PATH 12
614 . 64 0 . 011 12 . 50 0. 1 40 . 1 Vel = 6.27
90 . 57 6 . 357 12 .50 40.3 40 .3
A4 C=120 0 . 00 0. 0 0 . 0 See PATH 15
705 .22 0 . 015 12 . 50 0 .2 40 .3 Vel = 7. 20
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
i
I
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 7
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 2 FROM HYDRAULIC REFERENCE 13 TO A8 CONTINUED
67 .49 6 .357 12 .50 40 . 4 40 .4
A5 C=120 0 . 00 0 . 0 0 . 0 See PATH 16
772 . 71 0 . 017 12 .50 0. 2 40 .4 Vel = 7. 89
53 . 88 6 .357 12 . 83 40 . 7 40 .7
A6 C=120 0 . 00 0 . 0 0 . 0 See PATH 17
826 . 59 0 . 020 12 . 83 0 . 3 40 .7 Vel = 8 .44
48 . 10 6 .357 12 . 17 40 . 9 40 . 9
A7 C=120 0 . 00 0. 0 0 . 0 See PATH 18
874 . 69 0 . 022 12 . 17 0 .3 40 . 9 Vel = 8 . 93
A8 874 . 69 41.2 K = 136 . 31
PATH 3 FROM HYDRAULIC REFERENCE 11 TO 47
38 . 82 1 . 049 1T 0 .33 12 . 0 12 . 0 K = 11.20
11 C=120 5 . 00 0. 0 0. 0
38 . 82 0 .444 5.33 2.4 12 . 0 Vel = 14 . 55
47 38 . 82 14.4 K = 10 .24
PATH 4 FROM HYDRAULIC REFERENCE 14 TO 44
37 .60 1 . 049 1T 0..33 11.3 11.3 K = 11.20
14 C=120 5. 00 0 . 0 0 . 0
37 . 60 0 .418 5.33 2 .2 11.3 Vel = 14 . 09
44 37 .60 13 .5 K = 10 .23
PATH 5 FROM HYDRAULIC REFERENCE 10 TO 48
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
;f�
I
I
I
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 8
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 5 FROM HYDRAULIC REFERENCE 10 TO 48 CONTINUED
39. 75 1. 049 1T 0.33 12 . 6 12 .6 K = 11.20
10 C=120 5. 00 0 . 0 0 . 0
39 . 75 0 .464 5 .33 2 .5 12 . 6 Vel = 14 . 90
48 39. 75 15. 1 K = 10 . 24
PATH 6 FROM HYDRAULIC REFERENCE 15 TO 43
37 . 63 1. 049 1T 0 .33 11.3 11.3 K = 11. 20
15 C=120 5 . 00 0 . 0 0 . 0
37 . 63 0 .419 5.33 2 . 2 11.3 Vel = 14 . 10
43 37 . 63 13 . 5 K = 10 .23
PATH 7 FROM HYDRAULIC REFERENCE 4 TO A2
32 .40 2 . 157 7.54 12 . 1 12 . 1 K = 9. 32
4 C=120 0 . 00 -0 .3 0 .0
32 .40 0 . 009 7. 54 0 . 1 12 .1 Vel = 2 . 87
38 . 62 2 . 157 7 .54 11. 9 11. 9 K = 11.20
5 C=120 0 . 00 -0 .3 0. 0
71. 02 0 . 041 7. 54 0 .3 11. 9 Vel = 6 .30
38 . 67 2 . 157 7 .54 11. 9 11 . 9 K = 11. 20
6 C=120 0 . 00 -0 .3 0.0
109. 69 0 . 091 7. 54 0 . 7 11. 9 Vel = 9. 73
39.34 2 . 157 7 .54 12 . 3 12 .3 K = 11. 20
7 C=120 0 . 00 0 . 0 0 .0
149. 03 0 . 160 7.54 1.2 12 .3 Vel = 13 . 21
41 .21 2 . 157 7 . 54 13 .5 13 .5 K = 11. 20
8 C=120 0 . 00 0.3 0 . 0
190 . 24 0 .251 7.54 1. 9 13 .5 Vel = 16. 87
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
�,�
,.
I
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 9
HYD. Qa DIA. FITTING PIPE Pt Pt
REF ITC" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft •TOTAL Pf Pn
PATH 7 FROM HYDRAULIC REFERENCE 4 TO A2 CONTINUED
44 . 38 2 . 157 1T 48 . 69 15 .7 15 .7 K = 11.20
9 C=120 12 . 31 1. 7 0 . 0
234 . 62 0 .370 60 . 99 22 . 6 15 . 7 Vel = 20. 80
6 .357 12 . 17 40.0 40 . 0
Al C=120 0 . 00 0. 0 0 . 0
234 . 62 0 . 002 12 . 17 0. 0 40 . 0 Vel = 2. 39
A2 234 . 62 40 . 0 K = 37. 08
PATH 8 FROM HYDRAULIC REFERENCE 4 TO B1
6 . 54 2 . 157 7 . 54 12 . 1 12 .1 K = 1. 88
4 C=120 0 . 00 0 .3 0 . 0
6 .54 0 . 000 7. 54 0. 0 12 . 1 Vel = 0 . 58
39.38 2 . 157 7 .54 12.4 12 .4 K = 11.20
3 C=120 0 . 00 0.3 0 . 0
45 . 92 0 . 018 7 .54 0. 1 12 .4 Vel - 4 . 07
40 . 02 2 . 157 7. 54 12. 8 12 . 8 K = 11.20
2 C=120 0 . 00 0 .3 0 . 0
85 . 94 0 . 058 7 .54 0 .4 12 . 8 Vel = 7. 62
41. 12 2 . 157 1T 22 . 64 13 . 5 13 .5 K = 11. 20
1 C=120 12 .31 0.4 0. 0
127 . 06 0 . 119 34 . 95 4.2 13 .5 Vel = 11. 27
B1 127 . 06 18 . 0 K - 29. 94
PATH 9 FROM HYDRAULIC REFERENCE 16 TO 42
38 . 15 1 . 049 1T 0 .33 11. 6 11 . 6 K = 11. 20
16 C=120 5 . 00 0 . 0 0 . 0
38 . 15 0 .430 5 . 33 2 .3 11. 6 Vel = 14 . 30
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 10
HYD. Qa DIA. FITTING PIPE Pt Pt
REF licit TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
42 38 . 15 13 . 9 K = 10 . 23
PATH 10 FROM HYDRAULIC REFERENCE 17 TO 41
39. 71 1. 049 1T 0 .33 12 . 6 12 .6 K = 11. 20
17 C=120 5. 00 0 . 0 0 . 0
39. 71 0 .463 5.33 2 .5 12 . 6 Vel = 14 . 88
41 39 . 71 15 .0 K = 10. 24
PATH 11 FROM HYDRAULIC REFERENCE 18 TO 40
42 .37 1. 049 1T 0 .33 14.3 14 .3 K = 11. 20
18 C=120 5 . 00 0 . 0 0 .0
42 .37 0 . 522 5 .33 2 . 8 14 .3 Vel = 15. 88
40 42 . 37 17 . 1 K = 10. 25
PATH 12 FROM HYDRAULIC REFERENCE 20 TO A3
47 . 77 2 . 157 7.54 22 . 1 22 . 1 K = 10 . 15
20 C=120 0 . 00 -0 .3 0. 0
47 . 77 0 . 019 7 .54 0 . 1 22 . 1 Vel = 4 . 24
52 .54 2 . 157 7.54 22 . 0 22 . 0 K = 11. 20
21 C=120 0. 00 -0.3 0 .0
100 .31 0 . 077 7.54 0 . 6 22 .0 Vel = 8. 89
52 . 91 2 . 157 1T 86.39 22 . 3 22 .3 K = 11. 20
22 C=120 12.31 1 . 2 0 . 0
153 .22 0 . 168 98.70 16 . 6 22 .3 Vel = 13 . 58
A3 153 .22 40 . 1 K = 24 . 19
PATH 13 FROM HYDRAULIC REFERENCE 20 TO B2
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
I
Abbatare Hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 11
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 13 FROM HYDRAULIC REFERENCE 20 TO B2 CONTINUED
4 . 92 2 . 157 7 .54 22 . 1 22 . 1 K = 1. 05
20 C=120 0 . 00 0 . 3 0 . 0
4 . 92 0 . 000 7 . 54 0 . 0 22 . 1 Vel = 0.44
53 . 02 2 . 157 1T 10 .48 22 .4 22.4 K = 11.20
19 C=120 12 .31 0.4 0. 0
57. 94 0 . 028 22 . 78 0 . 6 22 .4 Vel = 5. 14
B2 57 . 94 23 .4 K = 11. 97
PATH 14 FROM HYDRAULIC REFERENCE 45 TO 46
6. 54 2 . 157 7. 54 13 . 7 13 . 7
45 C=120 0 . 00 0 .3 0 . 0 See PATH 2
6. 54 0 . 000 7 . 54 0 . 0 13 . 7 Vel = 0.58
46 6 . 54 14 . 0 K = 1. 75
PATH 15 FROM HYDRAULIC REFERENCE B3 TO A4
90 . 57 2 . 157 2T 119.49 31. 1 31. 1
B3 C=120 24. 61 0 . 0 0 . 0 See PATH 1
90 . 57 0 . 064 144 . 10 9.2 31. 1 Vel = 8..03
A4 90 .57 40 . 3 K 14.27
PATH 16 FROM HYDRAULIC REFERENCE B4 TO A5
67 .49 2 . 157 1T 4 . 16 35. 1 35. 1
B4 C=120 12 . 31 -0. 1 0 . 0 See PATH 1
67 .49 0 . 037 16 .46 0 . 6 35 . 1 Vel = 5. 98
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
,:
i
Abbatare hangar Bldg E Drawing Date: 4125108 8:13
Tyco Fire Products Page 12
HYD. Qa DIA. FITTING PIPE Pt Pt
REF "C" TYPES FTNG'S Pe Pv ******* NOTES *******
POINT Qt Pf/ft TOTAL Pf Pn
PATH 16 FROM HYDRAULIC REFERENCE B4 TO A5 CONTINUED
2 . 157 9 .87 35.6 35 . 6
50 C=120 0 . 00 -0.4 0 . 0
67.49 0 . 037 9 .87 0.4 35. 6 Vel = 5. 98
2 . 157 1T 105 .47 35 . 6 35.6
49 C=120 12 .31 0.5 0. 0
67.49 0 . 037 117 . 77 4 .3 35. 6 Vel = 5. 98
A5 67 .49 40 .4 K = 10. 61
PATH 17 FROM HYDRAULIC REFERENCE B5 TO A6
53 . 88 2 . 157 2T 119.49 37. 1 37. 1
B5 C=120 24 .61 0 . 0 0. 0 See PATH 1
53 .88 0 . 024 144 .10 3 .5 37. 1 Vel = 4. 78
A6 53 . 88 40 .7 K = 8.45
PATH 18 FROM HYDRAULIC REFERENCE B6 TO A7
48 . 10 2 . 157 2T 119.49 38 . 1 38 . 1
B6 C=120 24 .61 0 . 0 0 . 0 See PATH 1
48 . 10 0 . 020 144 . 10 2 .8 38 . 1 Vel = 4 .26
A7 48 . 10 40 . 9 K = 7. 52
UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI)
i
T
0
T
o- Q- U) o
0) 0) O N
O O L T
O
a
rn
ai 0
w =3 --
SO
_ E E ._ ._
U) aacncn o
C. m m n. a _ o
00mc) mco
T
� m -t �
T /A
0 04
on
W - —
N
E Eaw
(n
N cn cn w- cu O
>, >, m (D
d () cn cn 2
_ E
cn U) a
000
Cl
0) N ,Oa.
O
N �
j
O cn _>
cn m
a)
a� _ COO O
a � NQ
U �
O O
U) W LL0J
W -
O)
O
m LO
(0 T
O)
C:
ca
(D0 — a c0.)
m LO � O
p) O co
Mr E
i /a) — —
Q T Q N
CVO O 000 COO 't N
I
1
f
tqC0 dire & BuildingI�Products
Technical Services:Tel: (800)381-9312/Fax: (800)791-5500
Series ELO-231 B — 11.2 K-factor
Upright and Pendent Sprinklers
Standard Response, Standard Coverage
sentative of all possible corrosive at-
General mospheres.Consequently,it is recom-
mended that the end user be consulted
Description with respect to the suitability of these
corrosion resistant coatings for any
The 11.2 K-factor, Series ELO-231 B, given corrosive environment. The ef-
Standard Response, Standard Cover- fects of ambient temperature,concen-
age, Upright and Pendent Sprinklers tration of chemicals,and gas/chemical t
(Ref. Figure 1) are automatic sprin- velocity, should be considered, as a S
klers of the frangible bulb type. They minimum, along with the corrosive na-
are "standard response - spray sprin- ture of the chemical to which the sprin-
klers" that produce a hemispherical klers will be exposed.
water distribution pattern below the
deflector. An upright intermediate level version of the Series ELO-231 B Sprinklers for -
The 11.2 K-factor, ELO-231 B Sprin- in-rack applications can be obtained
klers were subjected to full scale,high- by utilizing the Series ELO-231 B Up-
piled storage, fire tests to qualify their right Sprinkler with the WSG-2 Guard
use in lieu of 5.6 or 8.0 K-factor stand- & Shield, and a pendent intermediate
and spray sprinklers for the protection level version of the Series ELO-231 B _of high-piled storage. Sprinklers can be obtained by utiliz-
Higher flow rates can be achieved at ing the Series ELO-231 B Pendent
much lower pressures with the 11.2 Sprinkler with the WS-2 Shield. If there
K-factor, ELO-231 B Sprinklers — is a possibility of the pendent interme-
making their use highly advantageous diate level version being exposed to
in high density applications, such as mechanical damage,a G-2 Guard can
the protection of high-piled storage. be added.
Wax or lead coatings can be used to WARNINGS
extend the life of the copper alloy com- The 11.2 K-factor, Series ELO-231B
ponents used in Series ELO-231B Upright and Pendent Sprinklers de-
sprinklers beyond that which would scribed herein must be installed and
otherwise be obtained when exposed maintained in compliance with this
to corrosive atmospheres. Although document, as well as with the applica-
wax, lead, and polyester coated sprin- ble standards of the National Fire Pro-
klers have passed the standard corro- tection Association, in addition to the
sion tests of the applicable approval standards of any other authorities ha v-
agencies, the testing is not repre- ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
maintain-
IMPORTANT The owner is responsible for maintain-
refer to Technical Data ing their fire protection system and de-
Always RECEIVED
vices in proper operating condition.
Sheet TFP700 for the `INSTALLER The installing contractor or manufac-
WARNING" that provides cautions turer should be contacted with any APR 2 9 2008
with respect to handling and instal- questions.
lation of sprinkler systems and com-
ponents. Improper handling and in- Installation of Series ELO-231B Pen- COA PERMIT CENTER
stallation can permanently damage dent Sprinklers in recessed escutch-
a sprinkler system or its compo- eons will void all sprinkler warranties,
nents and cause the sprinkler to fail as well as possibly void the sprinkler's13-
to operate in a fire situation or cause Approvals and/or Listings.
it to operate prematurely.
Pagel of 6 MARCH, 2007 TFP342
- u
Page 2 of 6 TFP342
SPRINKLER FINISH
TYPE TEMPERATURE BULB NATURAL CHROME LEAD WAX WAX
LIQUID BRASS PLATED COATED COATED OVER LEAD
UPRIGHT 155°F/68-C Red 3
(TY&151 200°F/93°C Green 1,2,3,4
TY5851) 286°F/141-C Blue 3 3(a)
155°F/68°C Red 3
PENDENT 200°F/93°C Green
(TY5251 1,2,3,4
286°F/141°C t Blue 3 3(a)
NOTES:
1. Listed by Underwriters Laboratories, Inc.(UL Listed).
2. Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL Listed).
3. Approved by Factory Mutual Research Corporation(FM Approved).
4. Approved by the City of New York under MEA 291-04-E.
(a). FM Approved for a maximum ceiling temperature of 150°F/66°C.
TABLE A
LABORATORY LISTINGS AND APPROVALS
FOR 11.2 K-FACTOR SERIES ELO-231B UPRIGHT AND PENDENT SPRINKLERS
(Refer to the Design Criteria Section)
Model/Sprinkler Technical Design Criteria
Identification Data UL and C-UL Listing
Requirements
Numbers Approvals The 11.2 K-factor, Model ELO-231 B
UL and C-UL Listed. FM and NYC Ap- (TY5151, TY5251 & TY5851) Sprin-
TY5151 -Upright 11.2K, 3/4"NPT proved. (Refer to Table A for complete (TY5151,
are to be installed in accordance
TY5251 -Pendent 11.2K, 3/4"NPT approval information including corro- klerswith N re t 13 standard sprinkler accordance
TY5851 -Upright 11.2K, 1/2"NPT sion resistant status. The approvals tion and area/density flow calculation
TY5151 is a redesignation for C5151. posi-
apply to the service conditions in. requirements for light, ordinary, or ex-
cated in the Design Criteria section.) tra hazard occupancies, as well as
G1871, and S2531.is a redesignation for C5251, Maximum Working Pressure high piled storage occupancies (solid
1871 175 psi (12,1 bar) piled,palletized, rack storage,bin box,
TY5851 is a redesignation for C5851. Discharge Coefficient and shelf storage including but not lim-
K= 11.2 GPM/psis/2 ited to Class I-IV and Group A plastics)
(161,4 LPM/bars/2) with a minimum residual (flowing)
pressure of 7 psi (0,5 bar) for wet or
Temperature Ratings dry pipe systems.
Refer to Table A
Finishes FM Approval
Refer to Table A Requirements
Physical Characteristics The 11.2 K-factor, Model ELO-231 B
Frame . . . . . . . . . . . . . Bronze (TY5151, TY5251 & TY5851) Sprin-
Cap . . . . . . . . . . . . . . Bronze klers are to be installed in accordance
Sealing Assembly . with the applicable"control mode den-
. Beryllium Nickel w/Teflont sity/area" guidelines provided by Fac-
Bulb(5 mm dia.) . . . . . . . Glass tory Mutual. (FM guidelines may differ
Compression Screw . . . . . Bronze from UL and C-UL Listing criteria.)
Deflector. . . . . . . . . . . . Bronze
t Registered trademark of DuPont.
.
, w
'
�
--- - - -- ----
/
~ |
|
|
/
|
/
TFP342 Page 3 of 6
*Temperature rating is indicated on deflector.
**Pipe thread connections per ISO 7/1 can be provided on 1/2"(12,7 mm)
special request. NOMINAL MAKE-IN
3/4"** 1
NPT
II Components:
2 1 - Frame
2-13/16" 2 - Seal
3 Assembly
(71,4 mm) WRENCH THREAD 3 - Cap
P. FLATS RELIEF 4 4 - Bulb
5 - Compression
5 Screw
1/2"** —— 3/4"** :�J L 6 - Deflector
NPT NPT 6
_ 7/16"(11,1 mm) 1 2"(12,7 mm)
NOMINAL MAKE-IN NOMINAL MAKE-IN
UPRIGHT UPRIGHT PENDENT CROSS
TY5851 TY5151 TY5251 SECTION
FIGURE 1
11.2 K-FACTOR SERIES ELO-231B
UPRIGHT-314"NPT(TY5151), UPRIGHT- 112"NPT(TY5851),AND PENDENT-314"NPT(TY5251)SPRINKLERS
Operation Installation "FITTING SIDE"
TOWARDS SPRINKLER
The glass bulb contains a fluid that The Series ELO-231 B Sprinklers must FITTING
expands when exposed to heat.When be installed in accordance with the fol-
the rated temperature is reached, the lowing instructions: 4
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to NOTES
activate and water to flow. Do not install any bulb type sprinkler if
the bulb is cracked or there is a loss of WRENCH
liquid from the bulb. With the sprinkler RECESS
held horizontally, a small air bubble
should be present. The diameter of the - (END 'A")
air bubble is approximately 1116 inch
(1,6 mm) for the 155°F168°C to 3132 FIGURE
inch (2,4 mm) for the 286°F1141°C W-TYPE 3 SPRINKLER
temperature ratings. WRENCH
A leak tight 314 inch NPT sprinkler joint
should be obtained with a torque of 10 installed in the pendent position, and
to 20 ft.lbs. (13,4 to 26,8 Nm).A maxi-
mum of 30 ft.lbs. (40,7 Nm) of torque upright sprinklers are to be installed in
is to be used to install sprinklers with the upright position.
314 NPT connections. A leak tight 112 Step 2. With pipe thread sealant ap-
inch NPT sprinkler joint should be ob- plied to the pipe threads, hand tighten
tained with a torque of 7 to 14 ft.lbs. the sprinkler into the sprinkler fitting.
(9,5 to 19,0 Nm).A maximum of21 ft.lbs. (28,5 Nm) of torque may be used Step 3. Tighten the sprinkler into the
to install sprinklers with 112 NPT con- sprinkler fitting using only the W-Type
nections. Higher levels of torque may 3 Sprinkler Wrench (Ref. Figure 2),
distort the sprinkler inlet and cause except that an 8 or 10 inch adjustable
leakage or impairment of the sprinkler. Crescent wrench is to be used for wax
coated sprinklers. With reference to
Do not attempt to make-up for insuffi- Figure 1, the W-Type 3 Sprinkler
cient adjustment in the escutcheon Wrench or the adjustable Crescent
plate by under- or over-tightening the wrench, as applicable is to be applied
sprinkler. Readjust the position of the to the wrench flats.
sprinkler fitting to suit.
When installing wax coated sprinklers
The Series ELO-231B Upright and with the adjustable Crescent wrench,
Pendent Sprinklers must be installed additional care needs to be exercised
in accordance with the following in- to prevent damage to the wax coating
structions. on the sprinkler wrench flats or frame
Step 1. Pendent sprinklers are to be arms and, consequently, exposure of
Page 4 of 6 TFP342
bare metal to the corrosive environ- It is recommended that automatic
ment. The jaws of the wrench should Care and sprinkler systems be inspected,
be opened sufficiently wide to pass - tested, and maintained by a qualified
over the wrench flats without damag- Maintenance Inspection Service in accordance with
ing the wax coating. Before wrench local requirements and/or national
tightening the sprinkler,the jaws of the Series ELO-231 B Sprinklers must be code.
wrench are to be adjusted to just con- maintained and serviced in accord-
tact the sprinkler wrench flats. After ance with the following instructions: Limited
wrench tightening the sprinkler,loosen
the wrench jaws before removing the NOTES
wrench. Before closing a fire protection system Warranty
After installation, the sprinkler wrench control valve for maintenance work on
and frame arms must be in- the fire protection system that it con- Products manufactured by Tyco Fire&
flats
flats and
and the wax coating in- trols, permission to shut down the af- Building Products (TFBP) are war-
touched (repaired)whenever the coat- fected fire protection system must be ranted solely to the original Buyer for
ing has been damaged and bare metal obtained from the proper authorities ten(10)years against defects in mate-
is exposed. The wax coating on the and all personnel who may be affected rial and workmanship when paid for
wrench flats can be retouched b by this action must be notified. and properly installed and maintained
Y 9en- under normal use and service. This
tly applying a heated 1/8 inch diameter Sprinklers that are found to be leaking warranty will expire ten (10) years
steel rod to the areas of wax that have or exhibiting visible signs of corrosion from date of shipment by TFBP. No
been damaged,to smooth it back over must be replaced. warranty is given for products or com-
areas where bare metal is exposed. Automatic sprinklers must never be ponents manufactured by companies
NOTES painted, plated, coated or otherwise not affiliated by ownership with TFBP
Only retouching of the wax coating a altered after leaving the factory. Modi- or for products and components which
y g g p- fied sprinklers must be replaced. have been subject to misuse,improper
plied to the wrench flats and frame Sprinklers that have been exposed to installation, corrosion, or which have
arms is permitted, and the retouching corrosive products of combustion, but not been installed, maintained, modi-
is to be performed only at the time of have not operated,should be replaced fied or repaired in accordance with ap-
the initial sprinkler installation. if they cannot be completely cleaned plicable Standards of the National Fire
The steel rod should be heated only to by wiping the sprinkler with a cloth or Protection Association, and/or the
the point at which it can begin to melt by brushing it with a soft bristle brush. standards of any other Authorities
the wax, and appropriate precautions Care must be exercised to avoid dam- Having Jurisdiction. Materials found
need to be taken, when handling the re TFBP o be defective shall P'either
heated rod, in order to prevent the age a the sprinklers. before,during, repaired or replaced, at TFBP's sole
and after installation. Sprinklers dam- option. TFBP neither assumes, nor
installer from being burned. P
aged by dropping, striking, wrench authorizes any person to assume for it,
If attempts to retouch the wax coating twist/slippage, or the like, must be re- any other obligation in connection with
with complete coverage are unsuc- placed.Also,replace any sprinklerthat the sale of products or parts of prod-
cessful, additional wax can be ordered has a cracked bulb or that has lost ucts.TFBP shall not be responsible for
in the form of a wax stick (the end of liquid from its bulb (ref. Installation sprinkler system design errors or inac-
which is color coded). Only the correct Section Note). curate or incomplete information sup-
co/or coded wax is to be used, and Frequent visual inspections are rec- plied by Buyer or Buyer's repre-
retouching of wrench flats and frame ommended to be initially performed for sentatives.
arms is only permitted at the time of corrosion resistant sprinklers,after the In no event shall TFBP be liable, in
initial sprinkler installation. With the installation has been completed, to contract, tort, strict liability liable,
under
steel rod heated as previously de- Y
scribed, touch the rod to the area re- verify the long term potential integrity any other legal theory, for incidental,
quiring additional wax with the rod an- of the sprinkler coatings. Thereafter, indirect,special or consequential dam-
annual inspections per NFPA 25 ages. including but not limited to labor
wax stick tortheand rodthen ap approximately atch ely should suffice; however, instead of in- charges, regardless of whether TFBP
pp y specting from the floor level,a random was informed about the possibility of
one-half inch away from the area re- sampling lin of close-up visual ins ec- p y
quiring retouching. The wax will melt tions should be made so as to better such damages, and in no event shall
and run down onto the sprinkler. TFBP's liability exceed an amount
determine the exact sprinkler condi-
tion and the long term integrity of the equal to the sales price.
corrosion resistant coating, as it may The foregoing warranty is made in lieu
be affected by the corrosive conditions of any and all other warranties. ex-
present. press or implied, including warranties
The owner is responsible for the in- of merchantability and fitness for a par-
spection, testing, and maintenance of ocular Rurpose,
their fire protection system and de- This limited warranty sets forth the ex-
vices in compliance with this docu- clusive remedy for claims based on
ment, as well as with the applicable failure of or defect in products, materi-
standards of the National Fire Protec- als or components, whether the claim
tion Association (e.g., NFPA 25), in is made in contract, tort, strict liability
addition to the standards of any other or any other legal theory.
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative
to any questions.
�i�
TFP342 Page 5 of 6
Ordering PIN 50 - XXX - X - XXX
Procedure
A Part Number (P/N) is not specified
when ordering sprinklers with thread
connections per ISO 7/1.
Contact your local distributor for avail- SPRINKLER
ability. TEMPERATURE
Sprinkler Assemblies TYPE 1 NATURAL BRASS RATING
with NPT Thread Connection: 510 UPRIGHT 9 CHROME PLATED 155 155°F/68°C
Specify: (specify SIN), 11.2 K-factor, 3/4"NPT
(specify temperature rating), Series (TY5151) 6 WAX COATED 200 200°F/93°C
ELO-231 B Standard Response(spec-
ify Pendent or Upright) Sprinkler with 512 PENDENT 7 LEAD COATED 286 286°F/141°C
(specify finish), P/N (specify from Ta- 3/4"NPT
ble B). (TY5251) 8 WAX OVER LEAD
Sprinkler Wrench: 501 UPRIGHT
Specify: W-Type 3 Sprinkler Wrench, 1/2"NPT
P/N 56-895-1-001. (TY5851)
Wax Sticks: TABLE B
(for retouching wrench damaged PRODUCT SYMBOL NUMBER SELECTION
wax coating) 11.2 K-FACTOR SERIES ELO-231B
Specify: (Specify color) color coded STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS
Wax Stick for retouching (specify tem-
perature rating)temperature rated Se-
ries ELO-231 B Sprinklers, P/N (spec-
ify).
Red for 155°F.......... P/N 56-065-1-155
Blue for 200°F and
286V........ ____ P/N 56-065-1-286
NOTES
Each wax stick is suitable for retouch-
ing up to twenty-five sprinklers.
The wax used for 286°F sprinklers is
the same as for 200°F sprinklers, and,
therefore, the 286°Fsprinkler is limited
to the same maximum ceiling tempera-
ture as the 200oF sprinkler (i.e.,
150°F).
I
I
I
Page 6 of 6 TFP342
TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446
I>fF ire & Building RECEIVED
roducts APR 2 9 2008
COA PERMIT CENTER
Technical Services: Tel: (800)381-9312/Fax: (800) 791-5500
'�l,sJ �vbSDi la'
Series TY-FRB — 5.6 K-factor
Horizontal and Vertical Sidewall Sprinklers
Quick Response, Standard Coverage
ment provided by the Recessed Es-
General _
cutcheon reduces the accuracy to
which the fixed pipe nipples to the
Description sprinklers must be cut.
The Series TY-FRB, 5.6 K-Factor, Corrosion resistant coatings, where
Horizontal and Vertical Sidewall Sprin- applicable, are utilized to extend the i►'' '�
klers described in this data sheet are life of copper alloy sprinklers beyond ;
quick response - standard coverage, that which would otherwise be ob-
decorative 3 mm glass bulb type spray tained when exposed to corrosive at-
sprinklers designed for use in light and mospheres. Although corrosion resis-
ordinary hazard,commercial occupan- tant coated sprinklers have passed the
cies such as banks, hotels, shopping standard corrosion tests of the appli-
malls, etc. They are designed for in- cable approval agencies,the testing is
stallation along a wall or the side of a not representative of all possible cor-
beam and just beneath a smooth ceil- rosive atmospheres. Consequently, it
ing. Sidewall sprinklers are commonly is recommended that the end user be
used instead of pendent or upright consulted with respect to the suitability
sprinklers due to aesthetics or building of these coatings for any given corro-
construction considerations, where sive environment.The effects of ambi-
piping across the ceiling is not desir- ent temperature, concentration of `
able. chemicals, and gas/chemical velocity,
should be considered, as a minimum,
The recessed version of the Series along with the corrosive nature of the t
TY-FRB Horizontal Sidewall Sprinkler chemical to which the sprinklers will be
is intended for use in areas with a exposed.
finished wall. It uses a two-piece Style _4
10 Recessed Escutcheon with 1/2 inch WARNINGS
(12,7 mm) of recessed adjustment or The Series TY-FRB Sprinklers de-
up to 3/4 inch(19,1 mm)of total adjust- scribed herein must be installed and
ment from the flush sidewall position, maintained in compliance with this
or a two-piece Style 20 Recessed Es- document, as well as with the applica- Technical
cutcheon with 1/4 inch (6,4 mm) of ble standards of the National Fire Pro-
recessed adjustment or up to 1/2 inch tection Association, in addition to the Data
(12,7 mm)of total adjustment from the standards ofany other authorities hav-
flush sidewall position. The adjust- ing jurisdiction. Failure to do so may Approvals
impair the performance of these de- UL and C-UL Listed.
vices. FM, LPCB, and NYC Approved.
The owner is responsible for maintain- (Refer to Table A for complete ap-
ing their fire protection system and de- proval information including corrosion
IMPORTANT vices in proper operating condition. resistant status.)
Always refer to Technical Data The installing contractor or sprinkler Maximum Working Pressure
Y manufacturer should be contacted Refer to Table B.
Sheet TFP700 for the "INSTALLER with any questions.
WARNING" that provides cautions Discharge Coefficient
with respect to hand ling and instal- MOdel�Sprinkler K=5.6 GPM/psis/2 (80,6 LPM/bars/2)
lation of sprinkler s stems and com- s
Temperature Ratingem
ponents. Improper handling and in- T
stallation can permanently damage Identification Refer to Table A.
a sprinkler system or its compo- Finishes
nents and cause the sprinkler to fail Numbers Sprinkler: Refer to Table A.
to operate in a fire situation or cause Recessed Escutcheon:White Coated,
it to operate prematurely. TY3331 - Horizontal Chrome Plated, or Brass Plated.
TY3431 - Vertical
Page 1 of 6 APRIL, 2006 TFP176
F•
I
I
i2age 2 of 6 TFP176
SPRINKLER FINISH(See Note 11)
K TYPE TEMP. BULB NATURAL CHROME WHITE**" LEAD
LIQUID BRASS PLATED POLYESTER COATED
135°F/57°C Orange
HORIZ. 155°F/68°C Red
SIDEWALL 1,2,3,4,9,10 1,2,3,9 1,2,3,9
(TY3331) 175°F/79°C Yellow
200°F/93°C Green
5.6 286°F/141°C Blue
1/2"
NPT RECESSED 135°F/57°C Orange
HORIZ. 155°F/68°C Red
SIDEWALL 1,2,4,9, 10 1,2,9 N/A
(TY3331)* 175°F/79°C Yellow
Figure 3 200°F/93°C Green
RECESSED 135°F/57°C Orange
HORIZ. 155°F/68°C Red
SIDEWALL 1,2,3,4,9 N/A
(TY3331)** 175°F/79°C Yellow
Figure 4 200°F/93°C Green
VERTICAL 135°F/57°C Orange
SIDEWALL 155°F/68°C Red
5.6 (TY3431) 5,6,7,8,9 5,6,7,9
1/2" Installed 175°F/79°C Yellow
NPT Pendent 200°F/93°C Green
or
Upright 286°F/141°C Blue
NOTES:
1.Listed by Underwriters Laboratories, Inc. (UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a
4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance.
2.Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary
Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance.
3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a
4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance.
4.Approved by the Loss Prevention Certification Board(LPCB Ref. No.007a/04)at a 4 to 6 inch(100 to 150 mm)top of
deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers.
5.Listed by Underwriters Laboratories, Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies.
6.Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard
Occupancies.
7.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies.
8.Approved by the Loss Prevention Certification Board(LPCB Ref. No.094a/06&007a/04)as Quick Response Sprinklers.
9.Approved by the City of New York under MEA 354-01-E.
10.Approved by the Loss Prevention Certification Board(LPCB Ref. No.094a/06)at a 4 to 6 inch(100 to 150 mm)top of
deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers.
11.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed
as Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as
Corrosion Resistant Sprinklers.
* Installed with Style 10(1/2"NPT)3/4"Total Adjustment Recessed Escutcheon.
**Installed with Style 20(1/2"NPT) 1/2"Total Adjustment Recessed Escutcheon.
***Frame and deflector only. Listings and approvals apply to color(Special Order).
TABLE A
LABORATORY LISTINGS AND APPROVALS
Y
Physical Characteristics
Frame . . . . . . . . . . . . . Bronze operation
Button . . . . . . . . . Brass/Copper
Sealing Assembly . . . . . The glass Bulb contains a fluid which
. . . Beryllium Nickel w/Teflont expands when exposed to heat.When a
Bulb . . . . . . . . . . . . . . . Glass the rated temperature is reached, the N
Compression Screw . . . . . Bronze fluid expands sufficiently to shatter the
HSW Deflector . . . . . . . . Bronze glass Bulb, allowing the sprinkler to
VSW Deflector . . . . . . . . Copper activate and water to flow. o
Patents a
U.S.A. 5,810,263 0
.a
� � � � � � � � T� �� �
•
TFP176 Page 3 of 6
SPRINKLER FINISH
K TYPE NATURAL CHROME WHITE LEAD
BRASS PLATED POLYESTER COATED
HORIZONTAL SIDEWALL 250 PSI(1T2 BAR)
(TY3331) OR 175 PSI(12,1 BAR)
175 PSI(12,1 BAR)
5.6 RECESSED HORIZ.
1/2" SIDEWALL(TY3331) (SEE NOTE 1) N/A
NPT
VERTICAL SIDEWALL
(TY3431) 175 PSI(12,1 BAR)
NOTES:
1.The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories, Inc.(UL);the Listing by
Underwriters Laboratories, Inc.for use in Canada(C-UL);and,the Approval by the City of New York.
TABLE B, MAXIMUM WORKING PRESSURE
Design * Temperature rating is DEFLECTOR
indicated on deflector or HAT 5
Criteria adjacent to orifice seat
on frame.
The Series TY-FRB Horizontal and **Pipe thread
Vertical Sidewall Sprinklers are in- connections per ISO 7/1
tended for fire protection systems de- can be provided on
signed in accordance with the stand- special request.
and installation rules recognized by the 6* 4 2 3 1
applicable Listing or Approval agency
(e.g., UL Listing is based on the re- 9/16" WRENCH 1/2'**
quirements of NFPA 13, and FM Ap- (14,3 mm) FLATS NPT
proval is based on the requirements of
FM's Loss Prevention Data Sheets).
Only the Style 10 or 20 Recessed Es-
cutcheon, as applicable, is to be used 0 -
for recessed horizontal installations.
1-13/16" 7/16"
(46,0 mm) (11,1 mm)
CENTERLINE NOMINAL
OF SPRINKLER MAKE-IN
WATERWAY 1-112"
~J(38,1 mm)
_ 2-3/16"
(55,6 mm)
1 -Frame STYLE ESCUTCHEON
2-Button PLATE SEATING 10 or 20 —
3-Sealing Assembly RECESSED SURFACE
4-Bulb ESCUTCHEON _
5-Compression
Screw
6-Deflector
2-7/8"DIA.
(73,0 mm)
FIGURE 1
5.6 K-FACTOR QUICK RESPONSE
SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331)SPRINKLERS
R
� �
I
I
Page 4 of 6 TFP176
Installation ARROW MUST
POINT AWAY
The Series TY-FRB Sprinklers must 7/16" FROM AND BE O
be installed in accordance with the fol- ESCUTCHEON (11,1 mm) PERPENDICULAR
lowing instructions: PLATE SEATING „** NOMINAL TO THE BACK
SURFACE NPT MAKE-IN WALL SURFACE
NOTES
Do not install any bulb type sprinkler if *6
the bulb is cracked or there is a loss of 1;0,w
liquid from the bulb. With the sprinkler 5
held horizontally, a small air bubble 2-3/16" 2-3/16"
should be present. The diameter of the (55,6 mm) (55,6 mm) 4
air bubble is approximately 1116 inch
(1,6 mm) for the 135°F/57°C to 3132 1 1/2,. it
2
inch (2,4 mm) for the 286°F1141'C (38,1 mm) FLATS
temperature ratings. 7 3
A leak tight 112 inch NPT sprinkler joint
should be obtained with a torque of 7 1
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- SHOWN SHOWN CROSS
mum of21 ft. lbs. (28,5 Nm)of torque PENDENT UPRIGHT SECTION
may be used to install sprinklers with
112 NPT connections. Higher levels of
torque may distort the sprinkler and 1-Frame 3-Sealing 4-Bulb 6-Deflector
cause leakage or impairment of the 2-Button Assembly 5-Compression 7-Ejection Spring
sprinkler. Screw
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon " Temperature rating is indicated on deflector or adjacent to orifice seat on frame.
plate by under- or over-tightening the **Pipe thread connections per ISO 7/1 can be provided on special request.
sprinkler. Readjust the position of the
sprinkler fitting to suit. FIGURE 2
The Series TY-FRB Horizontal and 5.6 K-FACTOR QUICK RESPONSE
Vertical Sidewall Sprinklers must be SERIES TY-FRB VERTICAL SIDEWALL(TY3431)SPRINKLERS
installed in accordance with the follow-
ing instructions.
Step 1. Horizontal sidewall sprinklers
are to be installed in the horizontal
position with their centerline of water- Step B.After installing the Style 10 or Care and
way perpendicular to the back wall and 20 Mounting Plate over the sprinkler
parallel to the ceiling.The word"TOP" threads,hand tighten the sprinkler into
on the Deflector is to face towards the the sprinkler fitting. Maintenance
ceiling. Step C. Tighten the sprinkler into the
The Series TY-BFR Sprinklers must
Vertical sidewall sprinklers are to be sprinkler fitting using only the W-Type be maintained and serviced in accord-
installed in the pendent or upright po- 7 Recessed Sprinkler Wrench (Ref. ance with the following instructions:
sition with the arrow on the Deflector Figure 6). With reference to Figure 1,
pointing away from the wall. the W-Type 7 Recessed Sprinkler NOTES
Step 2. With pipe thread sealant ap- Wrench is to be applied to the sprinkler Before closing a fire protection system
plied to the pipe threads, hand tighten wrench flats. main control valve for maintenance
the sprinkler into the sprinkler fitting. Step D. After the ceiling has been in- work on the fire protection system that
Step 3. Tighten the sprinkler into the stalled or the finish coat has been ap- it controls, permission to shut down
sprinkler fitting using only the W-Type plied, slide on the Style 10 or 20 Clo- the affected fire protection system
6 Sprinkler Wrench (Ref. Figure 5), sure over the Series TY-FRB Sprinkler must be obtained from the proper
With reference to Figure 1 or , and push the Closure over the Mount- authorities and all personnel who may
r 2 the
WType 6 Sprinkler Wrench to be ing Plate until its flange comes in con- be affected by this action must be no-
applied to the wrench flats. tact with the ceiling tified.
The Series TY-FRB Recessed Hori- The owner must assure that the sprin-
zontal Sidewall Sprinklers must be klers are not used for hanging of any
installed in accordance with the follow- objects; otherwise, non-operation in
ing instructions. the eventofa fire or inadvertent opera-
tion may result.
Step A. Recessed horizontal sidewall Absence of an escutcheon, which is
sprinklers are to be installed in the used to cover a clearance hole, may
horizontal position with their centerline delay the time to sprinkler operation in
of waterway perpendicular to the back
wall and parallel to the ceiling. The afire situation.
word "TOP"on the Deflector is to face Sprinklers that are found to be leaking
towards the ceiling. or exhibiting visible signs of corrosion
ti
Y
TFP176 Page 5 of 6
5/8t 1/4"
(15,9t6,4 mm)
FACE OF Z, (END
ENCH RECESS
MOUNTING _ SPRINKLER "A"USED FOR
SURFACE "NPT MODELS)
FITTING
FIGURE 5
CLOSURE W-TYPE 6 SPRINKLER WRENCH
2-7/8"DIA.
SERIES (73,0 mm) WRENCH
RECESS
TY FRB I 2-1/4"DIA.
(57,2 mm)
MOUNTING -
PLATE
1/8" PUSH WRENCH
(3,2 mm) IN TO ENSURE
ENGAGEMENT
1-1/4"(31,8 mm) 3/4"(19,1 mm) WITH SPRINKLER
3/4"(19,1 mm) 1/4"(6,4 mm) WRENCHING AREA
FIGURE 3 FIGURE 6
SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER W-TYPE 7 RECESSED
WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT SPRINKLER WRENCH
STYLE 10 RECESSED ESCUTCHEON
1/2t1/8" must be replaced.
(12,7t3,2 mm) Automatic sprinklers must never be
FACE OF painted, plated, coated or otherwise
MOUNTING SPRINKLER altered after leaving the factory. Modi-
SURFACE fied sprinklers must be replaced.
FITTING Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated,should be replaced
CLOSURE if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
2-7/8"DIA. by brushing it with a soft bristle brush.
(73,0 mm) Care must be exercised to avoid dam-
SERIES age to the sprinklers - before, during,
TY FRB — 2-1/4"DIA. and after installation. Sprinklers dam-
(57,2 mm) aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler
MOUNTING that has a cracked bulb or that has lost
PLATE liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
1/8" ommended to be initially performed for
(3,2 mm) corrosion resistant coated sprinklers,
after the installation has been com-
1-1/4"(31,8 mm) 1/2"(12,7 mm) pleted,to verify the integrity of the cor-
rosion resistant coating. Thereafter,
1"(25,4 mm) 1/4"(6,4 mm) annual inspections per NFPA 25
should suffice; however, instead of in-
FIGURE 4 specting from the floor level,a random
SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER sampling of close-up visual inspec-
WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT tions should be made, so as to better
STYLE 20 RECESSED ESCUTCHEON determine the exact sprinkler condi-
tion and the long term integrity of the
•u.
5 ��
� �.� � � � � T � � � � �
v
Page 6 of 6 TFP176
P/N 57 — XXX — X — XXX
SPRINKLER TEMPERATURE
MODEUSIN RATING
378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F/57°C
375 VERTICAL SIDEWALL TY3431 4 WHITE POLYESTER 155 155°F/68°C
3 WHITE RAL9010)* 175 175°F/79°C
9 CHROME PLATED 200 200°F/93°C
7 LEAD COATED 286 286°F/141°C
TABLE C *Eastern Hemisphere sales only.
PART NUMBER SELECTION
SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS
corrosion resistant coating, as it may standards of any other Authorities
be affected by the corrosive conditions Having Jurisdiction. Materials found Ordering
present. by TFBP to be defective shall be either
repaired or replaced, at TFBP's sole Procedure
The owner is responsible for the in- option. TFBP neither assumes, nor
spection, testing, and maintenance of authorizes any person to assume for it, When placing an order, indicate the
their fire protection system and de- any other obligation in connection with full product name. Refer to the Price
vices in compliance with this docu- the sale of products or parts of prod- List for complete listing of Part Num-
ment, as well as with the applicable ucts.TFBP shall not be responsible for bers.
standards of the National Fire Protec- sprinkler system design errors or inac- Contact your local distributor for avail-
tion Association (e.g., NFPA 25), in curate or incomplete information sup- ability.
addition to the standards of any other plied by Buyer or Buyer's repre-
authorities having jurisdiction. The in- sentatives. Sprinkler Assemblies with NPT
stalling contractor or sprinkler manu- In no event shall TFBP be liable, in Thread Connections:
facturer should be contacted relative contract, tort, strict liability or under Specify: (Specify Model/SIN), Quick
to any questions. any other legal theory, for incidental, Response, (specify K-factor), (specify
It is recommended that automatic indirect,special or consequential dam- temperature rating), Series TY-FRB
sprinkler systems be inspected, ages, including but not limited to labor (specify Horizontal Sidewall or Vertical
tested, and maintained by a qualified charges, regardless of whether TFBP Sidewall) Sprinkler with (specify type
Inspection Service in accordance with was informed about the possibility of of finish or coating), P/N (specify from
local requirements and/or national such damages, and in no event shall Table C).
codes. TFBP's liability exceed an amount
equal to the sales price. Recessed Escutcheon:
Specify: Style (10 or 20) Recessed
Limited The foregoing warranty is made in lieu Escutcheon with (specify*)finish, P/N
of any and all other warranties. ex- (specify*).
Warranty press or implied, includipg warranties
of merchantability and fitness foraDar- *Refer to Technical Data Sheet TFP770.
Products manufactured by Tyco Fire& ticular ILRse•
Building Products (TFBP) are war- This limited warranty sets forth the ex- Sprinkler Wrench:
ranted solely to the original Buyer for clusive remedy for claims based on Specify: W-Type 6 Sprinkler Wrench,
ten(10)years against defects in mate- failure of or defect in products, materi- P/N 56-000-6-387.
rial and workmanship when paid for als or components, whether the claim Specify: W-Type 7 Sprinkler Wrench,
and properly installed and maintained is made in contract, tort, strict liability P/N 56-850-4-001.
under normal use and service. This or any other legal theory.
warranty will expire ten (10) years
from date of shipment by TFBP. No This warranty will apply to the full ex-
warranty is given for products or com- tent permitted by law.The invalidity, in
ponents manufactured by companies whole or part, of any portion of this
not affiliated by ownership with TFBP warranty will not affect the remainder.
or for products and components which
have been subjectto misuse,improper
installation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446
.-WILKINS Model P1
Backflow Preventers
wtih PostIndicatorGate Valve
SPECIE CATnN SUBMITTAL SHEET
APPLICATION
Designed for installation on potable water lines to protect
against both backsiphonage and back pressure. The level
' of backflow protection is dependent upon the assembly
specified.The Post Indicator Gate Valves are supplied with
a universal indicator post flange and operating nut, which
are easily adaptable to vertical indicator posts and wall type
MODELS indicator posts. Indicator Posts are used in fire protection
systems or other installations where it is necessary to tell
❑350 ',O�350DA ❑450 ❑450DA ❑ 375 at a glance if the valve is in the open or closed position and
❑375DA ❑475 ❑475DA ❑475V ❑475DAV a sealed housing is required.
SIZES STANDARDS COMPLIANCE
See specfic Model specification sheets for approval status.
❑ 4" '-E" ❑ 8" _ x y�
FEATURES
Maximum working water pressure 175 PSI
Maximum working water temperature 140°F
Hydrostatic test pressure 350 PSI ' 4
End connections
(Grooved for steel pipe) AWWA C606
(Flanged) ANSI B16.1 F
Class 125
0
OPTIONS
(Suffixes can be combined)
❑ OSYPI - with OS&Yflanged inlet gate connection and ° G
Post Indicator flanged outlet gate connection MODEL475VOSYPIFG SHOWN
❑ OSYPIG - with OS&Y grooved inlet gate connection and
Post Indicator grooved outlet gate connection
❑OSYPIFG - with OS&Y flanged inlet gate connection and
Post Indicator grooved outlet gate connection
❑ LM - less water meter
❑ - with gpm meter(standard) Igo
❑ - with cu ft/min meter x
❑ FS - with cast iron wye strainer(flanged only) '
❑ FSC - with epoxy coated wye strainer(flanged only) o •- bo
O O
ACCESSORIES
❑ Repair Kit
-C-� E
❑ Thermal expansion tank(Model WXTP) r+����®
❑ OS&Y Gate Valve tamper switch(OSY-40) B — RECEIVED
A
MODEL 350DAOSYPIFG SHOWhPR 2 9 2008
DIMENSIONS(do not include packaging)
DIMENSIONS (approximate) I ` ;;_ TER
SIZE A B C D(NRS D(OS&Y D(OS&Y E F G X
gates) open) closed)
in. mm in. mm in. I mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
4 100 37 5/8 956 19 1/2 495 9 229 14 3/4 375 22 3/4 578 18 1/4 464 6 152 21 533 18 481 10 1/8 257
6 150 44 3/4 1137 23 1/2 597 10 1/2 267 19 483 30 1/8 765 23 3/4 603 7 178 22 559 21 533 13 1/2 343
8 200 60 3/4 1543 37 3/4 959 12 305 22 1/2 572 37 3/4 959 29 1/4 743 8 1/2 216 37 7/8 962 30 770 17 3/8 441
D• REVISION:
i
Page 1 of 2 BF-PI 81
J-
TYPICAL INSTALLATION
t` --.
Local codes shall govern installation requirements. Unless
otherwise specified, the assembly shall be mounted at a
minimum of 12"(305mm)and a maximum of 30"(762mm) SUPPLIED BY OTHERS
above grade or adequate drains with sufficient side clearance
for testing and maintenance.
Capacity thru Schedule 40 Pipe (GPM)
Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec
2 1/2" 75 112 149 224
3" 115 173 230 346
4" 198 298 397 595
6" 450 675 900 1351
8" 780 1169 1559 2339
10" 1229 1843 2458 3687 -
DIRECTION OF FLOW 2D::'J
TYPICAL INSTALLATION 350DAOSYPIFG
- SUPPLIED BY OTHERS
SUPPLIED BY OTHERS
P
�
dsw.oxt
II
II
11
II
P
II
11
II
DRNN
-' DIRECTION OF FLOWS DIRECTION OF FLOW
TYPICAL INSTALLATION 475VOSYPIFG TYPICAL INSTALLATION 3500SYPI
SPECIFICATIONS
The Backflow Preventer with Post Indicator shall be of a Double Check, Double Check Detector, Reduced Pressure
Principle, or Reduced Pressure Detector type. The Backflow Assembly shall be ASSE ® Listed. The main body and
access cover shall be epoxy coated ductile iron(ASTM A536 Grade 4),the seat ring and check valve shall be NORYLT"'
and the seat disc elastomers shall be EPDM.TheAssembly shall include an OS&Y as well as a Post Indicator gate valve.
The Assembly shall be a WILKINS Model 300 or 400 Series Backflow Prevention Assembly.
Page 2 of 2
WILKINS OPERATION OF ZURN INDUSTRIES,1747 Commerce Way,Paso Robles,CA 93446 Phone:805/238-7100 Fax:805/238-5766
IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga,Ontario L4V 11-2 Phone:905/405-8272 Fax:905/405-1292
Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com
...�: .
r�
I
i
I
tyCO Fire & ,wilding
Products
Technical Services: Tel: (800)381-9312/Fax: (800) 791-5500
Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-factor
Upright, Pendent, and Recessed Pendent; Sprinklers
Quick Response, Standard Coverage
tained when exposed to corrosive at-
General mospheres. Although corrosion resis-
tant coated sprinklers have passed the
Description standard corrosion tests of the appli-
cable approval agencies,the testing is
The Tyco® Series TY-FRB, 2.8, 4.2, not representative of all possible cor-
5.6,and 8.0 K-factor, Upright and Pen- rosive atmospheres. Consequently, it
dent Sprinklers described in this data is recommended that the end user be At
sheet are quick response - standard consulted with respect to the suitability
coverage, decorative 3 mm glass bulb of these coatings for any given corro-
type spray sprinklers designed for use sive environment.The effects of ambi-
in light or ordinary hazard,commercial ent temperature, concentration of � !
occupancies such as banks, hotels, chemicals, and gas/chemical velocity,
shopping malls, etc. should be considered, as a minimum,
The recessed version of the Series along with the corrosive nature of the
TY-FRB Pendent Sprinkler,where ap- chemical to which the sprinklers will be
plicable, is intended for use in areas exposed.
with a finished ceiling. It uses either a An intermediate level versions of the 41
two-piece Style 10 (1/2 inch NPT) or Series TY-FRB Pendent Sprinklers
Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet l
cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de-
recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780
(19,1 mm)of total adjustment from the
flush pendent position, or a two-piece WARNINGS -�
Style 20(1/2 inch NPT)or Style 30(3/4 The Series TY-FRB Sprinklers de-
inch NPT) Recessed Escutcheon with scribed herein must be installed and
1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this
ment or up to-1/2 inch (12,7 mm) of document, as well as with the applica-
total adjustment from the flush pen- ble standards of the National Fire Pro-
dent position. The adjustment pro- tection Association, in addition to the
vided by the Recessed Escutcheon re- standards of any other authorities hav- ModellSprinkler
duces the accuracy to which the fixed ing jurisdiction. Failure to do so may
pipe drops to the sprinklers must be impair the performance of these de-
Identification
cut. vices.
Corrosion resistant coatings, where The owner is responsible for maintain- Numbers
applicable, are utilized to extend the ing their fire protection system and de-
life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2"NPT
that which would otherwise be ob- The installing contractor or sprinkler TY1231 - Pendent 2.81K, 1/2"NPT
manufacturer should be contacted TY2131 - Upright 4.21K, 1/2"NPT
with any questions. TY2231 - Pendent 4.21K, 1/2"NPT
IMPORTANT TY3131 - Upright 5.61K, 1/2"NPT
Always refer to Technical Data TY3231 - Pendent 5.61K, 1/2"NPT
Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.01K, 3/4"NPT
WARNING" that provides cautions TY4231 - Pendent 8.01K, 3/4"NPT
with respect to handling and instal- TY4831- Upright 8.OK, 1/2"NPT
lation of sprinkler systems and com- TY4931- Pendent 8.OK, 1/2"NPT
ponents. Improper handling and in-
stallation can permanently damage y
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely. APR 2 9 2008
COA PERMIT CENTER
Page 1 of 10 AUGUST, 2007 TFP171
I�("D�o 08 O 10�-
O
I
II
■ �
I
Page 2 of 10 TFP171
ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20
PLATE SEATING NOMINAL RECESSED SSU*
SURFACE NPT MAKE-IN ESCUTCHEON DEFECTOR
i 6
5
2-1/4" } 7/16"
(57,2 mm) NO NALmm) 4
NOMINAL
MAKE-IN 2
1-9/16" 2-3/16"
3
(39,7 mm) WRENCH (55,6 mm)
f FLATS I 1
7
SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. —�I 1/2"NPT +
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression 7-Bushing orifice seat on frame.
Screw
FIGURE 1
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS
2.8 K-FACTOR, 112 INCH NPT
ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20
PLATE SEATING NOMINAL RECESSED
SURFACE 1/2 MAKE-IN ESCUTCHEON SSU
NPT I DEFLECTOR
6*
T 7/16" ---� 5
2-3/16" I (11,1 mm)
(55,6 mm) NOMINAL — 4
MAKE-IN
11(38,11 m 2
WRENCH (55,6 mm)
FLATS 3,
1
SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. _ 1/2"NPT
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression orifice seat on frame.
Screw
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS
4.2 K-FACTOR, 112 INCH NPT
.f
I
I
I
TFP171 Page 3 of 10
ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20
PLATE SEATING NOMINAL RECESSED
SURFACE NPT -IN ESCUTCHEON DEFLECTOR
6*
7/16" 5
2-3/16" (11,1 mm)
(55,6 mm) NOMINAL 4
MAKE-IN
1-1/2" 2-3/16" 2
(38,1 mm) WRENCH I (55,6 mm) � 3
FLATS
I
1
SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA �I 1/2"NPT
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression orifice seat on frame.
Screw
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS
5.6 K-FACTOR, 112 INCH NPT
ESCUTCHEON 1/2"(12,7 mm) STYLE 30 or 40
PLATE SEATING NOMINAL RECESSED
SURFACE 3/4 MAKE-IN ESCUTCHEON SSU
NPT DEFLECTOR
6*
1/2" 5
(58,7 mm) NOMINAL 4
MAKE-IN
1-9/16" 2-1/4" 2
(39,7 mm) WRENCH (57,2 mm) 3
FLATS '
' 1
SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. — 3/4"NPT
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression orifice seat on frame.
Screw
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS
8.0 K-FACTOR, 314 INCH NPT
- - r-- �-..r -.. �- --- - - - - ��- � - - - - - -
I
I
I
Page 4 of 10 TFP171
7/16"(11,1 mm)
1/2" NOMINAL SSu*
NPT MAKE-IN DEFLECTOR
* 6
1 - � 5
2-1/4" 2-3/16"
(57,2 mm) (55,6 mm) 4
1-9/16" WRENCH 2
(39,7 mm) FLATS
3
SSP* 1
DEFLECTOR CROSS
PENDENT UPRIGHT SECTION
1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression orifice seat on frame.
Screw
FIGURE 5
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS
8.0 K-FACTOR, 112 INCH NPT
Technical Operation
Data The glass Bulb contains a fluid which
expands when exposed to heat.When
Approvals the rated temperature is reached, the
UL and C-UL Listed. fluid expands sufficiently to shatter the
FM, LPCB, and NYC Approved. glass Bulb, allowing the sprinkler to
(Refer to Table A and B for complete activate and water to flow.
approval information including corro-
sion resistant status.) Design
Maximum Working Pressure
Refer to Table C. criteria
Discharge Coefficient
K=2.8 GPM/psit/2 (40,3 LPM/bars/2) The Series TY-FRB Pendent and Up-
K=4.2 GPM/psis/2 (60,5 LPM/bars/2) right Sprinklers are intended for fire
K=5.6 GPM/psis/2 (80,6 LPM/bars/2) protection systems designed in ac-
K=8.0 GPM/psi1/2(115,2 LPM/bars/ ) cordance with the standard installation
rules recognized by the applicable
Temperature Ratings Listing or Approval agency (e.g., UL
Refer to Table A and B Listing is based on the requirements of
Finishes NFPA 13, and FM Approval is based
Sprinkler: Refer to Table A and B. on the requirements of FM's Loss Pre-
Recessed Escutcheon:White Coated, vention Data Sheets ). Only the Style
Chrome Plated, or Brass Plated. 10, 20, 30, or 40 Recessed Escutch-
eon, as applicable, is to be used for
Physical Characteristics recessed pendent installations.
cu
Frame . . . . . . . . . . . . . Bronze E
Button . . . . . . . . . Brass/Copper
Sealing Assembly
Beryllium Nickel w/Teflont
Bulb . . . . . . . . . . . . . . . Glass
Compression Screw . . . . . Bronze Mn
Deflector . . . . . . . Copper/Bronze
Bushing (K=2.8) . . . . . . . Bronze
0
a
0
�i
I
TFP171 Page 5 of 10
SPRINKLER FINISH(See Note 7)
K TYPE TEMP. BULB NATURAL CHROME j WHITE***
LIQUID BRASS PLATED POLYESTER
135°F/57°C Orange
PENDENT 155°F/68°C Red
TY1231
and ) 175°F/79°C Yellow 1,2,3,5
UPRIGHT 200°F/93°C Green
2.8 (TY1131)
286°F/141°C Blue
1/2"
NPT 135°F/57°C Orange
RECESSED
PENDENT 155°F/68°C Red
(TY1231)* 175°F/79°C Yellow
Figure 6 200°F/93°C Green 1,2,5
135°F/57°C Orange
RECESSED
PENDENT 155°F/68°C Red
(TY1231)** 175°F/79°C Yellow
Figure 7 200°F/93°C Green
135°F/57°C Orange
PENDENT 155°F/68°C Red
(TY2231)
and 175°F/79°C Yellow
UPRIGHT 200°F/93°C Green
4.2 (TY2131)
286°F/141°C Blue 1 2
1/2"
NPT 135°F/57°C Orange
RECESSED
PENDENT 155°F/68°C Red
(TY2231)* 175°F/79°C Yellow
Figure 8 200°F/93°C Green
135°F/57°C Orange
RECESSED 155°F/68°C Red
PENDENT
(TY2231)** 175°F/79°C Yellow
Figure 9 200°F/93°C Green
NOTES:
1.Listed by Underwriters Laboratories, Inc. (UL)as Quick Response Sprinklers.
2.Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL)as Quick Re-
sponse Sprinklers.
3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprin-
klers.
5.Approved by the City of New York under MEA 354-01-E.
7.Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprin-
klers are UL and C-UL Listed as Corrosion Resistant Sprinklers.
* Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment
Recessed Escutcheon,as applicable.
**Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT) 1/2"Total Adjustment
Recessed Escutcheon,as applicable.
***Frame and Deflector only. Listings and approvals apply to color(Special Order).
N/A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
2.8 AND 4.2 K-FACTOR SPRINKLERS
i
Page 6 of 10 TFP171
SPRINKLER FINISH(See Note 8)
K TYPE TEMP. BULB NATURAL I CHROME i WHITE*- LEAD
LIQUID BRASS I PLATED POLYESTER COATED
135°F/57°C Orange
PENDENT 155°F/68°C Red
(TY3231) 1,2,3,4,5,6,7 1,2,3,5
and 175°F/79°C Yellow
UPRIGHT 200°F/93°C Green
5.6 (TY3131)
286°F/141°C Blue
112"
NPT 135°F/57°C Orange
RECESSED 155°F/68°C Red
PENDENT 1,2,4,5 N/A
(TY3231)* 175°F/79°C Yellow
Figure 10 200°F/93°C Green
135°F/57°C Orange
RECESSED 155°F/68°C Red
PENDENT 1,2,3,4,5 N/A
(TY3231)** 175°F/79°C Yellow
Figure 11 200°F/93°C Green
135°F/57°C Orange
PENDENT 155°F/68°C Red
(TY4231) 1,2,5
and 175°F/79°C Yellow 1,2,3,4,5,6,7
UPRIGHT 200°F/93°C Green
8.0 (TY4131)
286°F/141°C Blue
3/4"
NPT 135°F/57°C Green
RECESSED 155°F/68°C Orange
PENDENT 1,2,4,5 N/A
(TY4231)* 175°F/79°C Red
Figure 12 200°F/93°C Yellow
135°F/57°C Orange
RECESSED 155°F/68°C Red
PENDENT 1,2,3,4,5 N/A
(TY4231)** 175°F/79°C Yellow
Figure 13 200°F/93°C Green
135°F/57°C Orange
PENDENT 155°F/68°C Red
8.0 (TY4931)
1/2" and 175°F/79°C Yellow 1,2,5
1,2,4,5,E
NPT UPRIGHT 200°F/93°C Green
(TY4831)
286°F/141°C Blue
NOTES:
1.Listed by Underwriters Laboratories, Inc.(UL)as Quick Response Sprinklers.
2.Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL)as Quick Response Sprinklers.
3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers.
4.Approved by the Loss Prevention Certification Board(LPCB Ref. No.007k/04)as Quick Response Sprinklers;however,the
LPCB does not rate the thermal sensitivity of recessed sprinklers.
5.Approved by the City of New York under MEA 354-01-E.
6.VdS Approved (For details contact Tyco Fire&Building Products, Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377).
7.Approved by the Loss Prevention Certification Board(LPCB Ref. No.094a/06)as Quick Response Sprinklers.
8.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as
Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a
Corrosion Resistant Sprinklers.
* Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable.
**Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable.
***Frame and Deflector only. Listings and approvals apply to color(Special Order).
N/A:Not Available
TABLE B
LABORATORY LISTINGS AND APPROVALS
5.6 AND 8.0 K-FACTOR SPRINKLERS
i
TFP171 Page 7 of 10
SPRINKLER FINISH
K TYPE NATURAL I CHROME I WHITE LEAD
BRASS I PLATED POLYESTER COATED
PENDENT(TY3231)
and
2.8 UPRIGHT(TY3131) 175 PSI(12,1 BAR) N/A
1/2 RECESSED PENDENT
NPT (TY323)
PENDENT(TY4231)
and
4.2 UPRIGHT(TY4131) 175 PSI(12,1 BAR) N/A
3/4" RECESSED PENDENT
NPT (TY4231)
PENDENT(TY3231)
and 250 PSI(17,2 BAR) 175 PSI(12,1 BAR)
5.6 UPRIGHT(TY3131) OR
1/2 RECESSED PENDENT 175 PSI(12,1 BAR)
NPT (TY3231)
(SEE NOTE 1) N/A
PENDENT(TY4231)
and 175 PSI(12,1 BAR) 175 PSI(12,1 BAR)
8.0 UPRIGHT(TY4131)
3/4" RECESSED PENDENT
NPT (TY4231) N/A
8.0 PENDENT(TY4931)
1/2" and 175 PSI(12,1 BAR) 175 PSI(12,1 BAR)
NPT UPRIGHT(TY4831)
NOTES:
1.The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc. (UL);the Listing by
Underwriters Laboratories, Inc.for use in Canada(C-UL);and,the Approval by the City of New York.
TABLE C, MAXIMUM WORKING PRESSURE
tained with a torque of 10 to 20 ft.lbs. the sprinkler into the sprinkler fitting.
Installation (13,4 to 26,8 Nm). A maximum of 30
ft.lbs. (40,7 Nm)of torque is to be used Step 3. Tighten the sprinkler into the
The Series TY-FRB Sprinklers must to install sprinklers with is NPT con- sprinkler fitting using only the W-Type
be installed in accordance with the fol- to install
Higher levels of torque may 6 Sprinkler Wrench (Ref. Figure 14).
lowing instructions: distort the sprinkler inlet and cause With reference to Figures 1, 2, 3, 4,
leakage orimpairmentofthe sprinkler. and 5,the W-Type 6 Sprinkler Wrench
NOTES is to be applied to the sprinkler wrench
Do not install any bulb type sprinkler if Do not attempt to make-up for insuffi- flats.
the bulb is cracked or there is a loss of cient adjustment in the escutcheon The Series TY-FRB Recessed Pen-
liquid from the bulb. With the sprinkler plate by under- or over-tightening the dent Sprinklers must be installed in
held horizontally, a small air bubble sprinkler. Readjust the position of the accordance with the following instruc-
should be present. The diameter of the sprinkler fitting to suit. tions.
air bubble is approximately 1116 inch The Series TY-FRB Pendent and Up- Step A. After installing the Style 10.
(1,6 mm) for the 135°F/57°C to 3132 right Sprinklers must be installed in 20, 30,or40 Mounting Plate,as appli-
inch (2,4 mm) for the 286°F/141°C accordance with the following instruc- cable, over the sprinkler threads and
temperature ratings. tions. with pipe thread sealant applied to the
A leak tight 112 inch NPT sprinklerjoint Step 1. Pendent sprinklers are to be pipe threads, hand tighten the sprin-
should be obtained with a torque of 7 installed in the pendent position, and kler into the sprinkler fitting.
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- upright sprinklers are to be installed in Step B. Tighten the sprinkler into the
mum of21 ft. lbs. (28,5 Nm)of torque the upright position. sprinkler fitting using only the W-Type
may be used to install sprinklers with 7 Recessed Sprinkler Wrench (Ref.
112 NPT connections. A leak tight 314 Step 2. With pipe thread sealant ap- Figure 15).With reference to Figure 1,
inch NPT sprinkler joint should be ob- plied to the pipe threads, hand tighten 2, 3, and 4, the W-Type 7 Recessed
I
I
Page 8 of 10 TFP171
2-7/8"DIA. 2-7/8"DIA.
5/8t1/4" (73,0 mm) 3/4"(19,1 mm) 1/2t1/8" (73,0 mm) 1/2"(12.7 mm)
(15,9t6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7t3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm)
FACE OF (57,2 MOUNTING FACE OF (57,2 mm) ~I
MOUNTING
SPRINKLER
PLATE SPRINKLER PLATE
FITTING FITTING
I 2m
81,
(3,2 M mm) ( m)
MOUNTING
MOUNTING SURFACE
SURFACE
i
CLOSURE SERIES 1-5/16"(33.3 mm) CLOSURE SERIES 1-5/16"(33,3 mm)
TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm)
FIGURE 6 FIGURE 7
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 112 INCH NPT 2.8 K-FACTOR, 112 INCH NPT
2-7/8"DIA. 2-7/8"DIA.
5/8t1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm)
1/2t1/8" 1/2"(12.7 mm)
(15,9t6,4 mm) 2-1/4"DIA. y 1/4"(6,4 mm) (12,7t3,2 mm) 2-1/4"DIA. y 1/4"(6,4 mm)
FACE OF (57,2 mm) I MOUNTING FACE OF r (57,2 mm)
SPRINKLER MOUNTING
PLATE SPRINKLER - PLATE
FITTING FITTING
1/8" i I 1/8"
(3,2 mm) (3,2 1 mm)
AMA I /
MOUNTING f
MOUNTING SURFACE
SURFACE
CLOSURE
SERIES 1-1/4" 31.8 mm) CLOSURE SERIES 1-1/4"(31,8 mm)
-
TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm)
FIGURE 8 FIGURE 9
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 112 INCH NPT 4.2 K-FACTOR, 112 INCH NPT
Sprinkler Wrench is to be applied to work on the fire protection system that altered after leaving the factory. Modi-
the sprinkler wrench flats. it controls,permission to shutdown the fied sprinklers must be replaced.
Step C. After the ceiling has been in- affected fire protection system must be Sprinklers that have been exposed to
stalled or the finish coat has been ap- obtained from the proper authorities corrosive products of combustion, but
plied, slide on the Style 10, 20, 30, or and all personnel who may be affected have not operated,should be replaced
40 Closure over the Series TY-FRB by this action must be notified. if they cannot be completely cleaned
Sprinkler and push the Closure over The owner must assure that the sprin- by wiping the sprinkler with a cloth or
the Mounting Plate until its flange k/ers are not used for hanging of any by brushing it with a soft bristle brush.
comes in contact with the ceiling. objects; otherwise, non-operation in Care must be exercised to avoid dam-
the event of a fire or inadvertent opera- age to the sprinklers - before, during,
tion may result. and after installation. Sprinklers dam-
Care and
Absence of an escutcheon, which is aged by dropping, striking, wrench
Maintenance used to cover a clearance hole, may twist/slippage, or the like, must be re-
delay the time to sprinkler operation in placed. Also, replace any sprinkler
The Series TY-FRB Sprinklers must a fire situation. that has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
be maintained and serviced in accord-
Sprinklers that are found to be leaking Section).
ance with the following instructions: or exhibiting visible signs of corrosion
must be replaced. Frequent visual inspections are rec-
NOTES ommended to be initially performed for
Before closing a fire protection system Automatic sprinklers must never be corrosion resistant coated sprinklers,
main control valve for maintenance painted, plated, coated or otherwise after the installation has been com-
�.
I
1
TFP171 Page 9 of 10
2-7/8"DIA 2-7/8"DIA.
5/8t1/4" (73,0 mm) 3/4"( 9.1 nunj (73.0 mm)
1/2t1/8" 1/2" 12,7 mm)
(15,9t6,4 mm) 2-1/4"DIA. y 1/4"(6,4 mm) (12,7t3,2 mm) 2-1/4"DIA. y 1/4"(6,4 mm)
FACE OF (57,2 mm) I MOUNTING FACE OF (57,2 mm)
MOUNTING
SPRINKLER
PLATE SPRINKLER — PLATE
FITTING FITTING
1/8" 1/8-
(3,2 mm) ( (3.2 m)
ILR
MOUNTING
MOUNTING SURFACE
SURFACE 4�!
CLOSURE SERIES 1-1/4"(31,F3 mm) CLOSURE SERIES 1-1/4"(31,8 mm)
TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm)
FIGURE 10 FIGURE 11
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 112 INCH NPT 5.6 K-FACTOR, 112 INCH NPT
2-7/8"DIA. _ 2-7/8"DIA.
5/8t1/4" (73,0 mm) 3/4"(19,1 mm) 1/2t1/8" (73,0 mm) 1/2"(12,7 mm)
(15,9t6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7t3,2 mm) 2-1/4"DIA. y 1/4"(6,4 mm)
FACE OF (57,2 mm) �I MOUNTING FACE OF (57,2 mm) I MOUNTING
SPRINKLER PLATE SPRINKLER — PLATE
FITTING FITTING
1/8" I 1/8"
(3,2 mm) (3,2 mm)
MOUNTING
MOUNTING SURFACE
SURFACE
CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm)
TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm)
FIGURE 12 FIGURE 13
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 314 INCH NPT 8.0 K-FACTOR, 314 INCH NPT
pleted,to verify the integrity of the cor- WRENCH
rosion resistant coating. Thereafter, RECESS
annual inspections per NFPA 25
should suffice; however, instead of in- WRENCH RECESS
specting from the floor level,a random (END"A"USED FOR
sampling of close-up visual inspec- 1/2"NPT MODELS)
tions should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the 6
corrosion resistant coating, as it may WRENCH RECESS PUSH WRENCH
be affected by the corrosive conditions (END"B"USED FOR IN TO ENSURE
present. 3/4"NPT MODELS) ENGAGEMENT
The owner is responsible for the in- FIGURE 14 WRENCHING IIH SPRINKLER
AREA
spection, testing, and maintenance of W-TYPE 6 SPRINKLER
their fire protection system and de- WRENCH FIGURE 15
vices in compliance with this docu- - W-TYPE 7 RECESSED
ment, as well as with the applicable SPRINKLER WRENCH
to an
standards of the National Fire Protec- er should be contacted relative
tion Association (e.g., NFPA 25), in to any questions.
addition to the standards of any other It is recommended that automatic Inspection Service in accordance with
local requirements and/or national
authorities having jurisdiction. The in- sprinkler systems be inspected,
codes.
stalling contractor or sprinkler manu- tested, and maintained by a qualified
i
Page 10 of 10 TFP171
P/N 57 - XXX - X - XXX
TEMPERATURE
MODEL/SIN RATING
SPRINKLER
330 2.8K UPRIGHT(1/2"NPT) TY1131 135 135°F/57°C
331 2.8K PENDENT(1/2"NPT) TY1231 1 NATURAL BRASS 155 155°F/68°C
340 4.2K UPRIGHT(1/2"NPT) TY2131 4 WHITE POLYESTER 175 175°F/79°C
341 4.2K PENDENT(1/2"NPT) TY2231 3 WHITE(RAL9010)* 200 200°F/93°C
370 5.6K UPRIGHT(1/2"NPT) TY3131 9 CHROME PLATED 286 286°F/141°C
371 5.6K PENDENT(1/2"NPT) TY3231 7 LEAD COATED
390 8.OK UPRIGHT(3/4"NPT) TY4131
391 8.OK PENDENT(3/4"NPT) TY4231 *Eastern Hemisphere sales only.
360 8.OK UPRIGHT(1/2"NPT) TY4831*
361 8.OK PENDENT(1/2"NPT) TY4931*
TABLE D
PART NUMBER SELECTION
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
In no event shall TFBP be liable, in
Limited contract, tort, strict liability or under Ordering
any other legal theory, for incidental,
Warranty indirect,special or consequential dam- Procedure
ages, including but not limited to labor
Products manufactured by Tyco Fire& charges, regardless of whether TFBP When placing an order, indicate the
Building Products (TFBP) are war- was informed about the possibility of full product name. Refer to the Price
ranted solely to the original Buyer for such damages, and in no event shall List for complete listing of Part Num-
ten(10)years against defects in mate- TFBP's liability exceed an amount bers.
rial and workmanship when paid for equal to the sales price. Contact your local distributor for avail-
and properly installed and maintained
under normal use and service. This The foreaoina warranty is made in lieu ability.
warranty will expire ten (10) years of any and all other warranties. ex
from date of shipment by TFBP. No Dress or implied, including warranties Sprinkler Assemblies with NPT
warranty is given for products or com- of merchantability and fitness for a Par_ Thread Connections:
ponents manufactured by companies ficular purpose,. Specify: (Specify Model/SIN), Quick
Response, (specify K-factor), (specify
not affiliated by ownership with TFBP This limited warranty sets forth the ex- temperature rating), Series TY-FRB
or for products and components which clusive remedy for claims based on (specify Pendent or Upright)Sprinkler
have been subject to misuse,improper failure of or defect in products, materi- with (specify type of finish or coating),
installation, corrosion, or which have als or components, whether the claim P/N (specify from Table D).
not been installed, maintained, modi- is made in contract, tort, strict liability
fied or repaired in accordance with ap- or any other legal theory. Recessed Escutcheon:
plicable Standards of the National Fire
Protection Association, and/or the This warranty will apply to the full ex- Specify: Style (10, 20, 30, or 40) Re-
standards of any other Authorities tent permitted by law.The invalidity, in cessed Escutcheon with(specify*)fin-
Having Jurisdiction. Materials found whole or part, of any portion of this ish, P/N (specify*).
by TFBP to be defective shall be either warranty will not affect the remainder.
*Refer to Technical Data Sheet TFP770.
repaired or replaced, at TFBP's sole
option. TFBP neither assumes, nor Sprinkler Wrench:
authorizes any person to assume for it, Specify: W-Type 6 Sprinkler Wrench,
any other obligation in connection with P/N 56-000-6-387.
the sale of products or parts of prod-
ucts.TFBP shall not be responsible for Specify: W-Type 7 Sprinkler Wrench,
sprinkler system design errors or inac- P/N 56-850-4-001.
curate or incomplete information sup-
plied by Buyer or Buyer's repre-
sentatives.
TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446