Loading...
HomeMy WebLinkAbout17910 59TH DR NE_BLD20080083_2026 CITY OF ARLIN-GTON 238 N.OLYMPIC AVE.-ARLINGTON,WA.98223 / PHONE:(360)403-3421 Permit #: BLD20080083 BUILDING PERMIT Project Address: 17910 59TH AVE NE, ARLINGTON Parcel No: PROPERTY O. ARLINGTON MUNICIPAL AIRPORT ARLINGTON MUNICIPAL AIRPORT ARLINGTON MUNICIPAL AIRPORT 18204 59TH DRIVE NE 18204 59TH DRIVE NE 18204 59TH DRIVE NE ARLINGTON,WA 98223 ARLINGTON,WA 98223 ARLINGTON,WA 98223 Phone:360,403 3471 Phone:360.403.3471 LICENSE#: EXP: Email: Email: PLt)MBING CONTRACTOR MECHANICAL CONTRACTOR Lie#: Ex : Lie#: Ex : DESCRIPTIONJOB DEMOLITION OF BUILDING AND CONCRETE FOUNDATION-Bldg. 17910 VALUATION: $0 PERMIT TYPE:Commercial PERMIT GROUP:Demolition NUMBER OF STORIES: 1 ITYPE OF CONSTRUCTION:Vb NUMBER OF DWELLING UNITS:0 JOCCUPANT GROUP:S CODE:2006 JOCCUPANT LOAD: EXISTING AREA PROPOSED AREA BASEMENT:0 1ST FLOOR:O 2ND FLOOR:0 BASEMENT:0 1 ST FLOOR:0 2ND FLOOR:0 3RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0 3RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0 FRONTiACK SIDE SETBACK ' SETBACK RE UIRED: PROPOSED: [REQUIRED: PROPOSED RE UIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O RE UIRED: PROPOSED SETBACK NOTES: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. Signal re Print Name Date 'leased By D to ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.UBC109/IBCI10/IRC110. ARCHIVE APPLICANT ASSESSOR OTHER I .: BLD20080083 CONDITIONS • The existing supply line is still live and will need to be protected until it can be disconnected and capped by the contractor at the main line. PERMIT FEES Descrippop Fee Amount Paid. BalanceDue_ C-Plumbing Permit Fee $0.00 $0.00 $0.00 C-Mechanical Permit Fee $0.00 $0.00 $0.00 Total Due: $0.00 $0.00 $0.00 INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. CALL FOR INSPECTIONS BUILDING/ENGINEERING/PARKS/UTILITIES/FINAL(360)435-0674 FIRE(360)403-3607 When calling for an inspection please leave the following information: Permit Number,Job Site Address,Type of Inspection beine requested,Contact Name and Phone Number,Date Prefereed,and whether you prefer mornine or afternoon. • None BLD20080083 - arusko Page 1 of 1 BLD - Building Permit Ver: 2008 Priority: FNWrm-77-1 #BLD20080083 owner: JARLINGTON MUNICIPAL AIRPORT- status: JAPPLIED address: 117910 59TH AVE NE, ARLINGTON post date: 4/2/2008 data screens: Select Screen... J functions: Select Permit Function... Derilolitiorr REVIEWS Add Review Remove Review Print Close Review I Description Assigned To Due Date ( ) Req? �_ ID ne? i ASSIGN 1026 P-Utilities Fees RSHEPARD 4/16/2008 0 Y N ASSIGN 1032 P-Utilities I LTAYLOR 4/16/2008 0 Y N ASSIGN 2000 C-Building I CYOUNG 4/16/2008 0 N ASSIGN 2008 C-Community Development I ARUSKO 4/16/2008 0 Y N ASSIGN MIL D http://coaweb2.arlington.local/permittrax/PermitTraxMain/wfPermitConsoleReviews.aspx?... 4/2/200 8 At, •r 1 4o0-vY °A. DEMOLITION 7 o PERMIT APPLICATION <�nr c,� Department of Community Development City of Arlington• 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3551 •FAX(360)403 3447 THIS APPLICATION MUST BE ACCOMPANIED TWO(2)SETS OF FULLY DIMENISIONED PLOT PLANS AND SITE CLEAN-UP PLAN, TWO(2) COPIES OF AN ASBESTOS ABATEMENT REPORT COMPLETED BY AN APPROVED AGENCY. Type of Permit: (check one) ( ) Residential (x)Commercial Project Address: 17910 & 17920 59TH AVE AND 18615 58TH AVE Parcel ID#: 00448200000100 Lot#: Subdivision: Valuation: $0 Building Area (SgFt)3168; 3233; 3920 No. of floors: 1.25; 1; 1 Number of Buildings: 3 Owner: ARLINGTON MUNICIPAL AIRPORT Phone Number: (360) 403-3470 Address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 Contact Person: JOSEPH ALEXANDER Phone Number: (3600 403-3471 CeIIPhone: (425) 754-1732 Fax: (360) 435-1012 E-mail: jalexander@ci.arlington.wa.us Address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 Scope of Work: DEMOLISH THREE OLD BUILDINGS AND CONCRETE FOUNDATIONS. THE PROJECT WILL BEGIN BY SALVAGING SOME LUMBER FOR RE-USE, THEN A CONTRACTOR OR THE DEPT. OF CORRECTIONS WILL BE HIRED TO FINISH THE DEMOLITION WORK. ALL ASBESTOS MATERIAL HAS BEEN REMOVED (SEE ATTACHED) . BUILDING 17910 59TH WILL BE DISCONNECTED FROM THE SEPTIC SEWER SYSTEM. THE SEPTIC SYSTEM WILL REMAIN ACTIVE BECAUSE ANOTHER BUILDING, 17928, IS STILL USING THE SYSTEM. BUIDLING 18615 58TH SEPTIC SYSTEM WAS DECOMMISSIONED IN 2006. BUILDING 17920 59TH DOES NOT HAVE SEWER. ALL OTHER UTILITIES WIIL BE DISCONNECTED-AND, IF NECESSARY, DECOMMISSIONED (WATER, GAS AND ELECTRICITY) PRIOR TO THE DEMOLITION. Contractor: CITY OF ARLINGTON, ARLINGTON MUNICIPAL AIRPORT Phone Number: (360) 403-3470 Address: 18204 59TH DRIVE NE City. ARLINGTON State: WA Zip Code: 98223 Contractor's License Number: NSA Expiration: N/A I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulations of the Stat of Washington. 'Ll OAO L fir; r,2.06 Applicants Signature —�Date ,lywIn A{ Jg( Print Applicants Name II CF I '�; APR 012008 FOR STAFF USE ONLY CCA PERMIT CENTER Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—14 Page 1 of 1 3/07 dwa :. ,:; � } 1 1� OFFICE COPY CITY OF ARLINGTON r-- BUILDING DEPARTMENT 7928 DATE - BY NO CH NGES, AUTHORIZED I � II UNLESS APPROVED BY 711 I X i BUILDING INSPECTOR X�X � uI ; > 17 20 Qo I �11`� I 2co ci I 1� �I In I 2 0 AC 1'I c5 6 I I �_ W v c OI 2 Qo 7 � � P 17 I � Ho-- --- I o' 1 44' n �If II X i � , I I I I I ' I I � i �, _ � �. �� i �' � ��: T CB I � ' o I ' kr► , ' > ', °° I� H I � i I ` i 118C 1 , I , I J87 1 :50 1 ABATEMENT DOCUMENTS BUILDINGS 17910& 17920 59TH AVENUE NE (AIR TRANSPORT BUILDINGS) MEMO-GARY BROCK, CORRECTIONAL INDUSTRIES/ENVIRONMENTAL SERVICES 10/29/2007 ASBESTOS WASTE SHIPMENT REPORT 11/04/2007 POLARIZED LIGHT MICROSCOPY TEST REPORT 08/30/2007 POLARIZED LIGHT MICROSCOPY TEST REPORT 12/26/2006 BUILDING 18615 59TH AVENUE NE (OLD FIREHALL BUILDING) MEMO-GARY BROCK, CORRECTIONAL INDUSTRIES/ENVIRONMENTAL SERVICES 01/15/2002 ASBESTOS AIR MONITORING ANALYSIS REPORT 08/08/2000 ASBESTOS AIR MONITORING ANALYSIS REPORT 08/09/2000 ASBESTOS WASTE SHIPMENT RECON 08/24/2000 BUILDING ASSESSMENT REPORT 11/30/1999 ANALYSIS REPORT- LEAD IN PAINT 10/26/1999 I ,. ,. I - 1029/2007 09:48 FAX 360 586 0036 FFC & E/S Q 002/004 Correctional Industries Memo Tol Dale Carman f From Gary Brock Dater 10/29/07 RC Abatement Project On 8/27107 Correctional Industries/Environmental Services removed approx. 1,500 sf of asbestos containing exterior siding board from the Alr Transport/Old firehouse building located at Arlington Airport.This removal was performed using certified asbestos workers under the direct supervision of a certified asbestos supwvlsor.All materials were property containerized and delivered to an authorized transporter for disposal at Northam Wasoo Co.landfill In Oregon.(See attached disposal manliest) During the removal a secondary layer of material was observed under the CAB. Two bulk samples of this materiel was collected and forwarded to an accredited laboratory for analysis. Results were negative for asbestos content. (See attached test report) The cement asbestos board was the only material removed. Baeed upon the good faith survey dated 1212SMS no other asbestos containing materials were,Identlffed In this building.However, care must be taken to insure that during any demolition, renovation or other activities, should any materials not addressed In the survey report be encountered, said materials not be disturbed until assessed by a certified AHERA budding Inspector, e Page i I - 10128/2007 08:49 FAX 360 586 0036 FFC 8 E/S 10004/004 ASN 4 ASBL vTOS WASTE SHIPMENT kir PORT FORM '''� PLEASE PRDIT OR TYPEI If you bave questlam,camed im local DEQ Reponsl OtRa in Portland at(503)229- 5364,Bohm at(103)3784240 ext.272,Medford at(541)776.6010 on 233.or Band at(541)399-6144 on 226,OR a • call(900)452.4011 for the lacation of your local regional DEQ office. WASTE GENERATOR.(CArttmct0r.Facllity,or Operator) 1. Asbestos removal site name and sddress: tab►Of AtlinAton airport 6111188th place ne Arlinow Wa Snohomish 99223 Street Clty/8tate c4mq zip Contact Poison: Dale Carmen Phone-, 425-754-7723 2. Operator's name and address; Correctional industries Environmental Scrviium Phone:(253)589-7370 P.O.Box 991059 3tillacoorn/Wa Plarce 98499 Strove OW/Stata cmwty zip 3. Waste disposal site: Northern Wasco Co,Landfill Phone: (541)943-00/9 2550 Steel Rd. The Dallas/Or. Waaoo 97058 Sorer chy1ftm couaW zip 4. Describe asbestos materisla; S. Contatinera: Number: 5barrishA barn Type: bane 6. Total quantity(cubic yards): 5 7.OPMUTOA'S CMUTMCATIONr I haft declare that the omrmis of dw aomipmem ere A*and eoaaelaty deeuibad above by p Ww ahippmg n end ere dus&W,pw1u4W.merkad sod laheled,and one is ell nespeeo m proper condition for etraeport uwr&%m all 6ovcn an reSladoot. All movemml of dda wbeetoe tao>sinin= mstaial is mwded go this wsrte Shipment Rid Pam. Name: Company:Correctional Indu,tries/Env.Sa. Si Date: 8/29/2007 TRANSPORT'ER(S): 8. Transpoft,01:( led 0 of materials) Agent: Company! Ll Address: /� Phone: J „� Signature: DaseU U� 9. Transporter 92:( wledgment of receipt of materials) Agent: Compatry: Address; Phone; Signature: : DISPOSAL:(Cartificafm of reoei;n of asbesbos maerials covered by this manifest,except as rAW in item I 1 below.) 10.Waste Disposal Site: WASCO C 12330 Steel RD.The Dallas Or.97056 Name and Title: 4Nv;gNtM119SftAAV&6SEP 200 Signature; AMIIIAtAL • _.. 11.DISCREPANCY SPACE:(Add attachments as deeded) 10/29,/2007 09:48 FAX 360 586 0036 FFC & E/S 1a003/004 'Aui, 30. 2UU1 1 . 35rM N"- tnvironmental Services No, 5232 P. 2/2 ORIONEnvironmental Services An X13v9ronrns9tnl Corn lianct COWUhing Firm Polarized Light Microscopy Test Report EPA Method 600/R-98/116 Client Correctional industries Environmental Services Date August 30.2007 PO Hex 41115 Page Page 1 of 1 7hunwger,WA 98504 Invoice 073897 Ann Gary Brock Date Received August 30,2607 project Number N/A Project Name Arlington Airport Old Firchouse Client Orion Sample Alfbestsos Other lumkI Number Stereo Scone_EYsm Tims1mgInt el ezlt Fibers AT007-001 70830.18 Exterlor Wallboard Crush ND - Cellulose 1Hlomogetteoue AT007-002 70830-19 Exterior Wallboard Crush ND - Cellulose Homogeneous Dup:Laboratory QA/QC Duplicate;M;Mastic((a),(b),(c),em.).Semple layer&numbered ftorn front to back. Comments: For layered samples,each component Ms boom 4m gynd&apar&tely. ND means non-detect for asbestos fibers by EPA Method 600/R-96/116.Diaclaimers: PLM has been known to miss asbestos in a small percentage of samples that contain asbestos. Thus,these laboratory rosulu represent due dlligenco,however negative or t1 %PLM results can not be guaranteed,Per EPA guidelines samples will be archived for 30 days then will be disposed of.This report may only be reproduced in full with written approval of ORION savuUnmental smvices. Analyzed By jd A AQP Reviewed By Nelson U.Mliee UF AI cn Clark Sr. Industrial Hygienist Liaborotory Analyst r 4AV TnVkMMental Comp&"Cbanrl ng Irasa t&210,Csnaay 34004-91"Avenue South • Suite 5 ♦ Federal 'Way, Washington 98003.6740 • Tacoma(253)952-6717 ♦ Seattle(253) 974-9119 ♦ Facsimile(253)927.4714 • Email Infb 0ri0nES,net WBE W2F9219763 r ORIONEnvironmental Services An Environmental Compliance Consulting Firm Polarized Light Microscopy Test Report EPA Method 600/R-98/116 Client Correctional Industries Environmental Services Date December 26, 2006 PO Box 41115 . Page Pagel of 2 Tumwater, WA 98504 Invoice 065532 ,Attn: Gary Brock Date Received December 19,2006 Project Number PO#ES000422 Project Name Arlington Airport Air Transportation,Office Client Orion Sample Asbestos Other Number Number Stereo Scope Exam Treatment Percent Tvne Fibers ATO-01-01a 61219-58a Wall Texture ND _ Assoc. w/ATO-01-01c 7, ATO-01-01b 61219-58b Joint Compound - <1 Chrysotile Cellulose Assoc. w/ATO-01-01c ATO-01-01c 61219-58c Wallboard - ND Homogeneous = ATO-01-02a 61219-59a Wall Texture - ND Assoc.w/ATO-01-02c ATO-01-02b 61219-59b Joint Compound - ND - Cellulose Assoc.w/ATO-01-02c ATO-01-02c 61219-59c Wallboard - ND - Homogeneous ATO-02-01a 61219-60a Ceiling Texture - ND - - Assoc.w/ATO-02-01c {' ATO-02-01b 61219-60b Joiiat Compound - ND - - Assoc.w/ATO-02-01c G ATO-02-01 c 61219-60c Wallboard - ND - Cellulose Homogeneous J,o ATO-03-01a 61219-61a Roofing Ash ND - Homogeneous ( ATO-03-01b 61219-61b Roofing Ash ND - - Assoc.w/ATO-03-01a I L ATO-03-01 c 61219-61 c Roofing Ash ND Cellulose Assoc.w/ATO-03-01a 34004-91h Avenue South ♦ Suite 5 ♦ Federal Way, Washington 98003-6740 ♦ Tacoma(253)952-6717 • Seattle(253)874-8118 • Facsimile(253)9274714 • Email Info@0rionES.net l d tiZS[ 'ON S;:1 ;s IVJU; UOJ 1 Au3 ! P 1*ON NVD:6 LOOT gyp( I r• . ORION Environmental Services An Environmental Compliance Consulting Firm Polarized Light Microscopy Test Report EP.A. Method 600/R-98/116 Client Correctional Industries Environmental Services Date December 26,2006 PO Box 41115 Page Page 2 of 2 Tumwater, WA 98504 Invoice 065532 Attn: Gary Brock Date Received December 19,2006 Project Number PO#ES000422 Project Name Arlington Airport Air Transportation Office Client Orion Sample Asbestos Other Number Number Stereo Scope Exam Treatment Percent Type Fibers 3 ATO-03-01d 61219-61d Rooting _ Ash ND - - Assoc. w/ATO-03-01 a `f ATO-04-01 a 61219-62a Ceiling Texture - ND - - Assoc_w/ATO-04-01c / ATO-04-01 b 61219-62b Joint Compound - ND, - Cellulose Assoc. w/ATO-04-01c ATO-04-01 c 61219-62c Wallboard ND - - Homogeneous ATO-05-01 61219-63 Window Putty - ND - - Homogeneous ' ATO-06-01 61219-64 Black/Light Gray polled Ash ND - Cellulose Roofing Fiberglass Homogeneous Dup:Laboratory QA/QC Duplicate;M;Mastic[(a),(b),(c),etc.]:Sample layers numbered from front to back. Comments: For layered samples,each component has been analyzed separately.ND means non-detect for asbestos fibers by EPA Method 600/R-98/116.Disclaimers: PLM has been(mown to miss asbestos in a small percentage of samples that contain asbestos. Thus negative PLM results cannot be guaranteed.Per EPA guidelines samples will be archived for 30 days then disposed of.This report may only be reproduced in full with written approval of ORION Environmental Services. �i Analyzed By OA 3' azkReviewed By dP.(�o__ Nelson B.Miles III ,Allen Clank Sr.Industrial Hygienist Laboratory Analyst Leai s%W EnvironmentidCompGat+ce ConsuCtiing Into the 214t Century 34004 -0 Avenue South • Suite 5 ♦ Federal Way, Washington 99003-6740 ♦ Tacoma(253)952-6717 ♦ Seattle(253) 874-8118 ♦ Facsimile(253)927-4714 ♦ Email Info@OrionES.net WRIP W71WO�.1976Z Z d tZSI 'ON sa31naag JVJUawuoa1nu3 131MON WyD:6 LOOZ gyp( i Memorandum To: Dale Carman R From: Gary Brock Date: 01/15/02 Re: Old Firehall Abatement On 8/7;00 and 8/8/00 Correctional Industries Environmental Services removed asbestos containing ceiling texturing, flooring tiles, cementinous wall board and pipe insulation from the"Old Fireball", located at Arlington Airport as identified on the Building Assessment Report dated 1 1/30'99. Based on the initial survey, abatement records and post abatement inspection, I am of the opinion that all identified asbestos containing materials have been removed from this building. Should any suspect materials not previously identified be encountered, they must not be disturbed until analyzed for asbestos content and if asbestos contamme be properly removed. 1 I ,. .� 3� I I 1 nuwit. KIAHDASSOCIATES 2539240323 P. 01 NOWICKI & ASSOCIATES, INC. ASBESTOS AIR MONITORING ANALYSIS REPORT Lab Number:00812 Project: Arlington Flrehouse PO #763 Z82 Page: 1 of 1 Client; Correctional Industries Date Sampled: 8-7-00 Date Analyzed: 8-8-00 Submitted By; Sid Corter Date: 8-8-00 Received By: REN Sample Description Type Time Start Flow Of Time End Rate Fiber # Sample A, PA Per Fiber/CC ^ P P0, P, C Total Time Total Fields 0011 CLEARANCE C E: 4:00 R: 15.0 Um I - On type C 211100 1 0.009 T: 80 min V: 1200 L S. R.- E. -- -- --- T. V. S: R- E: ----- T. V: S: R: E: -- i -- -- - T: V: I —S. R.. - E: — —- --- T V: S: R. - E: T- V: (A) Area Sample (PA) Pre Abatement (PO) Post Abatement (P) Personal (C) Clearance Comments: — - — Analyst: F ast Microscopy (PCM): NIOSH Analytical Method 7400, A Rules jection Limit: 2 FJBERS/100 FIELDS tltaion Limit (LOL): 10 FIBERS/100 FIELDSn Anelytical Testing (PAT) PROGRAM ID NUMBER: 98003001 33516 9"'Avenue South, Bldg #6 • Federal Way, WA 98003 (253) 927-5233 (253) 924-0323 FAX � � � ' _ i I�._.�v v AUG-09-00 03 :34 PM NOWICKIANDASSOCIATES 'P39240323 P. 01 NOWICKI & ASSOCIATES, INC. ASBESTOS AIR MONITORING ANALYSIS REPORT Lab Number. 00814 Pape: 1 of 3 ProlOCt: Arlington Fire House AW.200 DaE e Sampled: 8-718.00 Client: Correctional Industries Date Analyzed: 8.9.00 Submitted 8y: Sidney Carter Date: 8-0-00 Received By: PAC; Sample Description Type Time Start Flow A. PA Time End Rate Fiber Sample PO, P, C Total Time Total Per Fiber/CC Fields 001 Fun Containment-Cslling Scrape S; 9:00 Pro Abatement PA R: 15.0 Um -� (1)A,I,p E: 10.29 34/100 T: 89 min V: 1335 L 0.012 002 Regulated Arse-Floor rileTSI/CAB S: 9:09 Pro Abatement P R: 15.0 Um q (1)A,I,p E: 10.33 38/100 0.014 Regulated Area-Floor T1le TSI/CAB T. 84 min V: 1200 L Q03 Randy Ferguson 532.78.0837 S: 12:00 R: 2.0 Urn 02037M P E: 3;00 Overload 1) 8-1-TWA(2)C.H,M T: 180 min V: 360 L w/dirt N/A I Regulated Area-Fbor Tile TSUCAB 004 Justin Ahlbom 537-68-2641 S: 12:00 R: 2.0 Um 020373-00 P E: 3:36 Overload (1)B,I,TWA(2)C,H,M T: 210 min V: 432 L I w/dirt N/A R0901ted Area--Floor Tile TSI/CAB Q05 Raymond Jackson 574-58.9107 P S: 12:06 R: 2,0 Urn 021005-00 STEL E: 12:39 (1) 9,I,STEL(2) C,H.M T: 33 min 37/20 1.373 Reg ulated Area-Floor Tile TSI/CAS V: 66 L 006 J0680 war 535-78•9447 P S: 12:06 R: 2.0 L/m 020381-00 STEL E; 12:40 (1)B,I,STEL 2)C,H,M T: 34 min V., B8 L �100 0.158 (A)Area Sample (PA) Pre Abatement (PO) Post Abatement P Person al net (C) Clearance Comments: Analyst: Phare Contras! Microscopy(PCM): NIOSH Analytical Method 7400,A Rules Min►rnum Delloction Limit: 2 FIBERS/100 FIELDS Lower Ouanititelon Llmlt (LOL): 10 FIBERS/100 FIELDS Pronclency In Anelyt;cal Testing (PAT)PROGRAM ID NUMBER: 08003001 33516 g"'Avenue South. BJdg;gt6 a •- ---•-•-•-•-•_._...-----•-•-•-... ....._ ...._._.-,-•-•_. ._._ ...._._ .,.._._..._._ _ Federal Way, WA 96003 • (253)927.5233 • (253)924.0323 FA X ii► cs f2,+,v I • RUG-09-08 03 :35 PM NOWICKIANDRsSOCIATES • -539240323 P. 02 NOWICKI & ASSOCIATES, INC, ASBESTOS AIR MONITORING ANALYSIS REPORT Lab Number: 00814 Pape; 2 of 3 Pro)ect: Arlington Fire House AW2o0 Oat le Sampled: 8.7/8.00 Client: Correctional Industries Submitted By: Sidney Carter Date Analyzed; 8.9-00 Date: 8.0.00 Received By: PAG Sample Deis cOripUon Type Tang Start Flow _ Sample A. PA Time End Rate Fiber PO, P. C Total Time Total Per Fiber/CC Full Containment-Ceiling Scrape Fields 007 Charles U 02o3eo0380 532-72-6537 P S: 1:20 R: 2.0 Um .� I(1) D,H,I,3TEL (2)C,H,M STEL E: 1:58 T: 38 min 21,1100 0.142 Full Containment-CallingV: 72 L I 00.8 Kenneth Driscoll 531-8 -4820 S; 1:22 R. 2.0 Um 020377-00 P E. 3:12 (1J B,t•i,t,TWA(2)C.H,M T: 110 min V: 13/100 0,028 Full Containment—Ceiling$crepe 220 L 009 Entrance to Decors S: 1:17 R: 15.0 Urn (1)A,0 A E: 2:38 29/100 0,011 T: 81 min V: 1215 L 010 I Full Cor tain.ment—Ceuing scrape I Negative Air Mechfne Exhaust S: 1:00 R: 15.0 Um A (1)A,0 E: 2:20 2/100 CUM T: 80 min V: 1200 L 012 Field Blank S: R: E: 1/100 T: V; N/A 013 Control Blank S: R: E• 0/100 N/A T: V.- (A)Area Sample (PA) Pre Abatement (PO) Post Abatement p) p Comments: ( Personal (C)Clearance Analyst: I [Prorkc4ency arm Contrast Microscopy(PCM): NOSH Anal nimum Detection Limlt: 2 FIBERS/100 FIELDS el Methed 7400,A Rules wer Quenrtitaion Limit(LOL): 10 FIBERa/100 FIELDS In Analytical Testing (PAT)PROGRAM ID NUMBER: 96003001 33516 9"r Avenue g -•---•---•-•-•-----•--_._._._._ .._._.-•--- -•-•- -•-•--- ---•--- -•--- -•-•---._ - -•- outh, 9ldg #6 Federal Way, WA 98003 • (253)027-5233 • (253)924-0323 FAX a` �_ r • "v%j O9-00 03 :35 PM "00'cKrANDASSOCIATMS '539240323 P- 03 NOWICKI & ASSOCIATES, INC. ASBESTOS AIR MONITORING ANALYSIS REPORT Lab Number:00814 ProJect: Arlington Fire House AW-200 Pages: 3 of 3 Client: Correctional Industries Dete'Sampled: 8.7/8.00 Date Analyzed: 8.9.00 Subi pitted 8y: Sidney Carter Date; $4.00 Received By: PAG Sample Description Type Time Start Flow Fiber Sample A. PA Time End Rate Per Finer/CC P0, P, C Total Time Total Fields RepulalsrJ er a-Floor Tile TSuCAB 014 Randy Fe0gugom 2037e-p0 -78-9837 P S: 8:30 R: 2.5 L/m E: 10;15 Overload (1)8,1,TWA(2) c.N,M T: 105 min V: 262.5 L w/dirt N/A Regulated Aren-Floor Tile TSI/CAB 01.5 Joeaph Wolf 535-78.9447 p S: 8:35 R: 2,0 Um 020381-00 I STEL E. Ue Overload N/A (1) B,I,STEL (2)C,H,M T: 31 min V: 82 L w/dlrt Old Regulated Arae-Floor Tile T31/CA3 S: 10:20 R: 15.0 Um CLEARANCE Sample C (1)A,l,C E- R: 43/100 0.017 I T: 80 min V: 1200 L Full Containment-Coiling Scrape 017 CLEARANCE Sampie R. 15.0 Um (1)A,. C C E: 12:00 No analysis necessary —_ T: 80 min V: 1200 L Ole Control Blank S: R: E: 0/100 NIA T: V: S: R: E: T: V. (A)Area Sample (PA) Pre Abatement (PO) Post Abatement (P) Personal O C Clearance Comments: Analyst: FPhaaeest Microscopy(PCM): NIQSH Anelytkal Method 7400, A Rules ection Limit:2 FIBERS/100 FIELDS italon Limit(LQL): 10 FIBERS/100 FIELDS Analytical Teatlnp (PAT)PROGRAM ID NUMBER; 98003001 33516 S"'Avenue South,h t3i . . . . . ._.....-•---•_.. ........_.- -------•- ,...-•---•-•- - -•- -•- . _._._._ dp � • Federal Way, WA 08003 ••(253) 027-5233 •• (253) 924-0 323 FAX i � • � . �� � � I :: Asbestos Waste Shipment Recon. 1.Work Site Name and Mailing Address: Owner's Name: Owners Telephone: Arlington Airport Fire House Arlington Municipal Airport 18204- 59th Drive NE (360)435-8554 G Arlington, WA 98223 E 2.Operator's Name and Address: Operators N Correctional Industries, Services Section/Asbestos Program Telephone: E Lakewood Industrial Park (253) 589-7370 R 9704-47th.Avenue S.W., Tacoma , Wa. 98499 A 3.Waste Disposal Site (WDS) Name, Mailing Address, and Physical WDS T Site Location: Oregon Waste Systems, Inc. Telephone: O Columbia Ridge Landfill & Recycling Center (541) 454-3318 R 18177 Cedar Springs Lane. Arlington,Oregon 97812 4. Name and Address of Responsible Agency: Puget Sound Air Pollution Control Authority 110 Union Street, Suite 500 Seattle, WA 98101-2038 5. Description of Materials: 6.Containers: 7. Volume (cu. yds.) VAT,TSI,CAB,Acoustic Ceiling No.: Type: 2.8 40 Bags - - - 8.Special Handling Instructions and Additional Information: Thorouqhly Wetted and Double Bagged. 9.Operator's Certification:I hereby declare that the contents of this consignment are fully and accurately described above by proper shipping name and are classified,packed, marked,and labeled,and are in all respects in proper condition for transport by highway according to applicable international and government regulations. Printed/Typed Name and Title: gnatu e: Date: Roy Syrovy; CIS-A 1= A 8/8/00 T 10.Transporter 1 (Acknowledgement of receipt tam erials R Printed/Typed Na a and Title: Pnnt rTypgd Name of Driver: Date: N Q,� � 6igd1%Ct Signature: S Address and Telephone Number: �� r�� �7r� P 3 x-.38$D O 117ransporter 2 (Acknowledgement of receipt of materials): R Printedfryped Name and Title: Printed/Typed Name of Driver: Date: T E Signature: R Address and Telephone Number: D 12.Discrepancy Indication Space: I S 13.Waste Disposal Site Owner and Operator: Certification of receipt of asbestos materials covered P by this manifest except as noted in Item 12. O Printedfryped Name and Title: Signature: Date: L msofficeWxcer%forms%wstman.xis Form WSR-20MI Correctional Indnstrin/Environmental Services Le4rw.d*WkMNd J%rlt ON4 410 Avow SMPO lox type. TOMM WA M4" Aiaffic f1s�Jdl�7.il6fax:pJ�a Sd�-7Jtt Building Assessment Report 1140/1999 Dale Carmsm Plant MVU4W Arlington Municipal Airport Audwr ty 18204 590 Drive N.E., Arlingtcm,WA 98223 Re:Old Fire StOce located on Ariingwn Airport Lot 35. CI 13rlvlronme2tal Services Job NBW 075 Dear Mr.Carman: Per your request to proceed of M20/99,we bave conducted a "good huth" limited asbtctos and leaf building survey usaurnsnt to deb rmine the prosence,condition and quanddes of asbestos and/or load eonuining mstcrlals found in the old fire station at the Arlinpoa Airport, Onr report is submitted on.[time tit materWs'not-to-Vxeed brain. Your oismnixation w dl be invoiced for laboratory tors time and labor costs and supplies. 17 Bulk samples of potential asbwtm containing mstxisis were taken for testinf in addition to 2 pr.int sae Iles to be tinted for lead content. sampled included! sheatrock,p4wtoz, bugdmg paper, window butt„te+crurtQ ceiling surfacin& exterior siding liner, floor tile, roofing materials vW paint, Mat+eriala found fo in aludo asbestos *w : I. Texture Ceiling(lasted in a small office on North side of auii4itmg; I Floor Tilt(located in a tool room lstore area on Somb side of buildiW 3. Plater(cementiRivus material located boncath ahaetrock on interior%411 of the old showedbrmroom, SE aomw of bwildhW d. TSI(pipe insulation)was prerent in small quatities(located in the oW ahVWa/b8 rocm area)and is presemM to cocain ACM Materials fotmd$o inches lead wero; 1, Exterior Paint(samnd locations over the eattsrior of buildW 2. ExtNIM'(7im Paint(10cRIORS sU01t as windows$door frames on"nor of bull&&, We have visually idattified suspected asbestos and W containing building materials, collwed buih samples of sur"acd materials,and oontr eW a qualified laboratory to analyze samples. The laboratory analysis rerort includes temple collection detsd s and laboratory arudysis of suspect materials. All samplings were condu.xd under the direct supervision of Mr.Gary Brock,an EPA accredited A BRA Inspector,eertLficatior,number L/NQ- NA1-9", S In ly, i Guy Brock AHLRA Building Impeceor I/MP-NAI.99.09 Coi roWmal Induaries/finvinotvtteatal Smicas 9704 47dk Avenue IW PO Box 9996S,Tuonu WA 92499 Phone:(233)SM7370 Fax:(20)S89.7383 MACS Lab, Int.. Ar>Ialysis Report 2070A Walsh Avenue Santa Clara, CA 95050.2542 (408) 727.9727 Lead In faint USEPA 7000/7420 Nowicki & Associates, Inc. Person to contact: Gary Brock 33516 9th Avenue S. - Bldg. 6 Contact phone: (253)927-5233 FAX phone: (253)924-0323 Federal Way WA 98003 Samples received on: October 25. 1999 Report prepared on: October 26. 1999 at:09:25 Ucrresponding invoice number: 82203 ,lob Number BW075 Charles Bond Analyst: Laboratory rnaiidgu:.--- _ (signature) (signal e) Job Description: DodC/Arlington Airport-Old Fire Station Lab sample Client Sample Numper Calti Rcvd AC LW Lead Number and Description # I OK Ieptdl ppm ! % ppm mWcm2 P82203.1 AFL-01-01 4904 ® ® 4,050 7.61 76,100 NIA Exterior paint P82203-2 AFL-02-01 4904 3,850 7.86 78,600 NIA Exterior paintArlm r End of report. Re:�EivD Nov 0 2 199g Cl TUNSPORTATION APO tC",F ACCI•;r PG# T is report may not be reproduced except in full and wiLli Il,d Nwrliilsslon of MAO$Lab, Inc.This report relates only to the hem(s)tested.For Quality Control data refer to Calibration Number GA Report MACS Lab is accredited by `•S the American Industrial I lyglene Association(All-IA)for the analysis of lead in paint and coil(laboratory ID 011172). Some paint samples submitted contain substrate material that can't be rerroved from the paint layer.This may onuoo orronoour,result:..Proper ficid cam piing tochniquoe must be usod. Samples are hot plate d'gested in Nitric AIHK Acid and Hydrogen Peroxide. Analysis is performed on a flame Atomic Absorption Spectrometer. LOD=Limit Of ACCRaDItTED DetscHmn. ppm_puts per million rt, 10,000 ppm=1% Nntw: 1 nV/Kg a 1 pprn NOTICE, FOR XAF Confirmation: LA50RATORY When the actual sampled area is provided to the laboratory. the resufts can be calculated in rrycm2 exactly like an XRF instrument resutt. Otherwise NO XRF comparison can ever be made because the lab analyzes only a tPage 1 portion of a normal sample and the area of a scrape can't be known after the fad. Without the area NIA Is reported. f1 - � , j I l 1 Permit Review Details Permit: BLD20080083 PERMIT 1020- P-Sewer Complete? Y 04104/2008 frapelyea 5 No Comments. Y Total Time: 5 1026 - P-Utilities Fees Complete? N Total Time: 0 1028 - P-Water Complete? Y 04/07/2008 eanderson 20 #1 The water meter has been pulled at this location Y #2 The existing supply line Is still live and will need to be protected until it can be disconected and capped by contractor at the main line. Total Time: 20 1032 - P-Utilities I Complete? Y 04/08/2008 Itaylor 5 No comments Y Total Time: 5 1034 - P-Utilities II Complete? Y 04/03/2008 jewing 0 No Comment Y Total Time: 0 1036 - P-Utilities III Complete? Y 04/04/2008 gschlagel 5 No Comment Y Total Time: 5 2000 - C-Building I Complete? Y 04/03/2008 cyoung 30 Contained asbestos abatement report. CK to issue Y Total Time: 30 2008 -C-Community Development I Complete? N Total Time: 0 Total Reviews: a Total Time: 65 4/8/2008 9:23:57 AM Page 1 of 1 I f . 1 ` r� t 4, 0 DEMOLITION PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3551 • FAX(360)403 3447 THIS APPLICATION MUST BE ACCOMPANIED TWO(2)SETS OF FULLY DIMENISIONED PLOT PLANS AND SITE CLEAN-UP PLAN, TWO(2) COPIES OF AN ASBESTOS ABATEMENT REPORT COMPLETED BYAN APPROVED AGENCY. Type of Permit: (check one) ( ) Residential (x) Commercial Project Address: Parcel ID#: � 17910 & 17920 59TH AVE AND 18615 58TH AVE 00448200000100 Lot#: Subdivision: Valuation: $0 Building Area(Sq Ft)3168; 3233; 3920 No. of floors: 1.25; 1; 1 Number of Buildings: 3 Owner: ARLINGTON MUNICIPAL AIRPORT Phone Number: (360) 403-3470 Address: 18204 59TH DRIVE NE City. ARLINGTON State: WA Zip Code: 98223 Contact Person: JOSEPH ALEXANDER Phone Number: (3600 403-3471 Cell Phone: (425) 754-1732 Fax: (360) 435-1012 E-mail: jalexander@ci.arlington.wa.us Address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 Scope of Work: DEMOLISH THREE OLD BUILDINGS AND CONCRETE FOUNDATIONS. THE PROJECT WILL BEGIN BY SALVAGING SOME LUMBER FOR RE-USE, THEN A CONTRACTOR OR THE DEPT. OF CORRECTIONS WILL BE HIRED TO FINISH THE DEMOLITION WORK. ALL ASBESTOS MATERIAL HAS BEEN REMOVED (SEE ATTACHED) . BUILDING 17910 59TH WILL BE DISCONNECTED FROM THE SEPTIC SEWER SYSTEM. THE SEPTIC SYSTEM WILL REMAIN ACTIVE BECAUSE ANOTHER BUILDING, 17928, IS STILL USING THE SYSTEM. BUIDLING 18615 58TH SEPTIC SYSTEM WAS DECOMMISSIONED IN 2006. BUILDING 17920 59TH DOES NOT HAVE SEWER. ALL OTHER UTILITIES WIIL BE DISCONNECTED AND, IF NECESSARY, DECOMMISSIONED (WATER, GAS AND ELECTRICITY) PRIOR TO THE DEMOLITION. contractor: CITY OF ARLINGTON, ARLINGTON MUNICIPAL AIRPORT Phone Number: (360) 403-3470 address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 ontractor's License Number: NSA Expiration: N/A ereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- �cribed property will be in accordance with the laws, rules and regulations of the Stat of Washington. Applicants Signature —r Date Print Applicants Name RECEIVED APR 012008 FOR STAFF USE ONLY COA PERMIT CENTER # Accepted By Amount Received Receipt# Date Received firms—14 Page 1 of 1 3/07 dwa r :. ,d -` �J j � � 1 ��� r�� .. � �:�u 1 _ 1 4.INC DEMOLITION PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3551 • FAX (360)403 3447 THIS APPLICATION MUST BE ACCOMPANIED TWO(2)SETS OF FULLY DIMENISIONED PLOT PLANS AND SITE CLEAN-UP PLAN, TWO(2) COPIES OF AN ASBESTOS ABATEMENT REPORT COMPLETED BY AN APPROVED AGENCY. Type of Permit: (check one) ( ) Residential (x)Commercial Project Address:L 1791E & 17920 59TH AVE AND 18615 58TH AVE Parcel ID#: 00448200000100 Lot#: Subdivision: Valuation: $0 Building Area (SgFt)3168; 3233; 3920 No. offloors: 1.25; 1; 1 Number of Buildings: 3 Owner: ARLINGTON MUNICIPAL AIRPORT Phone Number: (360) 403-3470 Address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 Contact Person: JOSEPH ALEXANDER Phone Number: (3600 403-3471 Cell Phone: (425) 754-1732 Fax: (360) 435-1012 E-mail: jalexander@ci.arlington.wa.us Address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 Scope of Work: DEMOLISH THREE OLD BUILDINGS AND CONCRETE FOUNDATIONS. THE PROJECT WILL BEGIN BY SALVAGING SOME LUMBER FOR RE-USE, THEN A CONTRACTOR OR THE DEPT. OF CORRECTIONS WILL BE HIRED TO FINISH THE DEMOLITION WORK. ALL ASBESTOS MATERIAL HAS BEEN REMOVED (SEE ATTACHED) . BUILDING 17910 59TH WILL BE DISCONNECTED FROM THE SEPTIC SEWER SYSTEM. THE SEPTIC SYSTEM WILL REMAIN ACTIVE BECAUSE ANOTHER BUILDING, 17928, IS STILL USING THE SYSTEM. BUIDLING 18615 58TH SEPTIC SYSTEM WAS DECOMMISSIONED IN 2006. BUILDING 17920 59TH DOES NOT HAVE SEWER. ALL OTHER UTILITIES WIIL BE DISCONNECTED AND, IF NECESSARY, DECOMMISSIONED (WATER, GAS AND ELECTRICITY) PRIOR TO THE DEMOLITION. Contractor: CITY OF ARLINGTON, ARLINGTON MUNICIPAL AIRPORT Phone Number: (360) 403-3470 Address: 18204 59TH DRIVE NE City: ARLINGTON State: WA Zip Code: 98223 Contractor's License Number: NSA Expiration: N/A I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulations of the Stat of Washington. 'Ll �G� 11 (, 2y"$ Applicants Signature �-Date Print Applicants Name RECEIVED APR 012008 FOR STAFF USE ONLY COA PERMIT CENTER ab. 0090633 -fhb- _e�5_ Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—14 Page 1 of 1 3/07 dwa