Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
103 E 3rd St_BLD5741_2026
_a COMMERCIAL PLUMBING APPLICATION e . Community&Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This includes commercial, tenant improvements, multi-family buildings, roof drains, and overflows, medical gas systems, commercial kitchens, grease traps and interceptors, sumps and cross connection backflow devices. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. SUBMIT THE FOLLOWING ELECTRONICALLY: El Plumbing plans or drawings. (Minimum plan size is 18"X 24"scale,Y4"scale for details.) El Fixture specifications and equipment(cut sheets)with locations. E1 Location and type of all backflow assemblies for each fixture. IN ADDITION TO ABOVE,SUBMIT THE FOLLOWING,IF APPLICABLE TO YOUR PROJECT: E1 Calculations for Grease Interceptor. El Pipe size and location of sanitary and potable water systems. El Riser diagram of waste,vent,and rain water systems,including sizes. ❑ Medical gas piping riser diagram,type of gas,storage room and size of piping. Type of Permit: ❑ New Installation ❑✓ Addition/Alteration/Repair ❑ Industrial Property Address: 103 E 3rd St Project Valuation: 7500.00 Lot#: Parcel ID No.: 00529900101200 Preferred Contact: O Owner X Contractor Installation of 3- comp sink, hand sink, floor sink, backflow preventer, and Project Description: gFeese ntereeptOF eeeefeling to plans. Dr. Gurpreet S. Khurana Owner Name: _ Office No.: Email Address: 365gsk@gmail.com Cell No.: 425-358-8888 Mailing Address: 14205 SE 36th St#365 City: Bellevue State: WA Zip: 98006 Contractor Name: Go Jo Plumbing Office No.: 206-491-2270 itis o o ahoo.com 206-276-9758 Email Address: 9 ) @Y Cell No.: 10426 State Route 530 NE Arlington WA 98223 Mailing Address: City: g State: Zip: L&I Contractor License Number: 6048855375 Expiration Date: March 21, 2024 _] REV1.2020 Page 1 of 3 PLUMBING PERMIT FEES(per fixture) Commercial plumbing permits are required to submit line drawings.A plan review fee of 65%per Table 4-6 for plumbing permits will be assessed at time of submittal.Includes two(2)inspections with permit. -Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly 1 x $25.00 = 25.00 Base Plumbin Fee $25.00 $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste x $25.00 = Clothes Washer x $15.00 = Dishwasher x $ 15.00 = Drinking Fountain x $ 15.00 = Floor Drains 1 x $15.00 115.00 Grease Interceptor 1 x $75.00 = 75.00 Grease Trap x $25.00 = Hose Bibb x $15.00 = Icemaker Refri erator 1 x $ 15.00 = 15.00 Irrigation-per meter x $25.00 = Kitchen Sink&Disposal x $ 15.00 = -Laundry Tray x $ 15.00 = -Lavatory x $ 15.00 = Med Gas Pi in <-5 inlets outlets x $60.00 = Med Gas Piping>5 inlets/outlets (plus<5 x $5.00 = inlets outlets Miscellaneous-regulated by plumbing x $15.00 = code,not otherwise specified Pretreatment Interceptor x $ 15.00 = -Re-inspection Fee all x $75.00 = Roof Drains x $ 15.00 = Shower(only) x $ 15.00 = Sink bar,service,etc. 4 x $ 15.00 = 60.00 Toilets x $15.00 = Urinal x $ 15.00 = Vacuum Breakers x $25.00 = Water Heater x $25.00 = Water Heater-Tankless x $25.00 = Permit Fee Table 4-6;Plan Review Fee Processing/Technology Fee $25.00 Total $240.00 REV1.2020 Page 2 of 3 PROPOSED BUILDING USE ❑ New ❑ Restaurant ❑ Automotive Based ❑ Addition/Alteration ❑ Office ❑ Machine Shop ❑ Industrial ❑ Medical ❑✓ Other: Coffee shop CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. ❑✓ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑✓ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ Swimming Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the plumbing system currently have a grease ❑ Yes ❑✓ No ❑ Don't Know interceptor? Does the plumbing system currently have an oil/water ❑ Yes ❑✓ No ❑ Don't Know separator? Is water used in the business process (washing,rinsing, a Yes ❑ No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑✓ Yes ❑ No ❑ Don't Know 1 hereby certify that I am the ❑Owner, []Applicant, []Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained when complete. Maurice Toenyan 12/8/2023 Signature Print Name Date SAVE PRINT REV1.2020 Page 3 of 3 ES-009 Engineering Specification Job Name Vintage Orchid Coffee Contractor Go Jo Plumbing Job Location 103 E 3rd St. Approval Engineer Contractor's P.O. No. Approval Representative Series 009 Reduced Pressure Zone Assemblies 1/4n _2rr f i e " It is illegal to use this product in any plumbing system providing - water for human consumption,such as drinking or dishwashing, in the United States.Before installing standard material product, consult your local water authority,building and plumbing codes. Series 009 Reduced Pressure Zone assemblies are designed to protect potable water supplies in accordance with national o09M2-OT-FS plumbing codes and water authority requirements.Specifically, the series protects drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements for non-potable service applications such as irrigation,fireline,or industrial processing. Test Cock No.3 Tes;Cock No.4 The series features two in-line, independent check valves, Ball Ty pe captured springs,and replaceable check seats with an Test Cocks intermediate relief valve. Its compact modular design facilitates Test Cock maintenance and assembly access.Sizes 1/4"to 1"shutoffs No.2 O have tee handles. �` v Series 009 assemblies of sizes 1h"to 2"include a flood sensor Second First Check Check to detect excessive water discharges from the relief valve.The Module % Module sensor is installed on the assembly exterior and does not alter Assembly Assembly assembly functions or certifications.The sensor relays a signal that i triggers notification to facility who can take corrective action,thus a avoiding the possibility of ruinous flooding and costly damage. 1 R.P.ZoneEVITOTHRIN ¢t Water Outlet An add-on connection kit is required to activate the flood Relief Valve Assembly sensor.Without the connection kit,the sensor is a passive component that has no communication with any other device. I® (For more information,download RP/IS-009.) Use of the flood sensor does not replace the need to comply Features with all required instructions, codes, and regulations related to installation;operation,and maintenance of this product, • Single access cover and modular check construction including the need to provide proper drainage in the event of for ease of maintenance a discharge. • Top entry to all internals for immediate accessibility Watts®is not responsible for the failure of alerts due to • Captured springs for safe maintenance connectivity or power issues. • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability(V4"-2") The information contained herein is not intended to replace the • Ball valve test cocks — screwdriver slotted(1/4"-2") full product installation and safety information available or the experience of a trained product installer.You are required to • Large body passages provides low pressure drop thoroughly read all installation instructions and product safety • Compact,space saving design information before beginning the installation of this product. • No special tools required for servicing Inquire with governing authorities for local installation • Sensor on the relief valve for flood detection(12"-2") requirements. Watts product specifications el U.S. leers and metric are banpdmete and are provided for reference only.Far precise or ma emends, X%IWATM pl�se contact Wald Technkal Service.Watts reserves the right to change or modify product design,construction,specifications,or materials vrith - outprier notice and wrtlwut Incurring any obligation to make such changes and mixiftadons on Watm products previously or su�querdy sold. Specification Pressure/Temperature A Reduced Pressure Zone assembly shall be installed at each Suitable for supply pressure up to 175 psi(12.1 bar) potential health hazard location to prevent backflow due to Water temperature:33°F—180°F(0.5°C—75°C) backsiphonage and/or backpnessure.The assembly shall consist of an internal pressure differential relief valve located in a zone Standards between two positive seating check modules with captured USC springs and silicone seat discs.Seats and seat discs shall be replaceable in both check modules and the relief valve.There ASSE No. 1013 shall be no threads or screws in the waterway exposed to line AWWA C511-92 fluids.Service of all internal components shall be through a CSA B64.4 single access bronze cover secured Jlh stainless steel bolts. The assembly shall also include two resilient seated isolation IAPMO File No. 1563 valves,four resilient seated test cocks,and an air gap drain fitting.The assembly shall meet the requirements of USC;ASSE Approvals Std. 1013;AWVUA Std.C511-92;CSA B64.4. Shall be a%Vat,sO Assrf� Series 009,and shall include a sensor on the relief valve for flood G o �� No detection. U USC-FCCCHR Model/Option 1013 c us Prefix: ASSE,AWWA,CSA, IAPMO U —Union connections(For more information Approved by the Foundation for Cross-Connection Control and download ES-0009 at watts.com.) Hydraulic Research at the University of Southern California Suffix: UL Classified 3/4"—2" AQT — Elbow fittings for 360'rotation(34"—2") (LF models only except 009M3LF) FS — Flood detection sensor(1/2"—2'j Insulated Enclosure HC — 212" Inlet/outlet fire hydrant fitting(2") The WattsBox insulated enclosure is available for Series 009. LF — Without shutoff valves For more information download ES-WB at watts.com. PC — Internal polymer coating QT — Quarter-turn ball valves S — Bronze strainer SH — Stainless steel ball valve handles Materials Bronze body construction,silicone rubber disc material in the first and second check plus the relief valve.Replaceable polymer check seats for first and second checks.Removable relief valve seats.Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional bronze union inlet and outlet connections,specify prefix U ('/2"—2").Series 009QT furnished with quarter turn,full port, resilient seated,bronze ball valve shutoffs. Dimensions — Weight Call customer service K you need assistance with technical details. 1/4 3A 1/211 _211 C C -T- N B —�— B N D - L - M — A -- M —----------------- A MODEL DIME14SIONS(APPROX.) STRAINER DIMENSIONS A B C u L M N in. in. mm in mm in. mm m. mm in. mm in. mm m. mm T kg 1/4 10 250 4% 117 3% 86 1% 32 5h 140 23A 60 2Ys 64 2 Sib 10 250 4% 117 3% 86 1'/ 32 5'h 140 23A 60 2'h 64 2 1/2 10 250 57A 149 33A 86 21h 64 5Yz 140 23A 70 2A 57 2 3/4 103/4 273 6A 159 Th 89 23A 70 6% 171 33AB 81 23/4 70 3 1 14'h 368 6% 159 3 76 1 3Y4 83 9h 241 33/4 95 3 76 12 5 1'/ MA 441 63iA 169 336 89 3'/4 83 113h 289 47/,e 113 3Yz 89 15 6 % 171A 454 6% 169 Th 89 3Y4 83 111'/ 283 47k 124 4 102 16 7 2 21* 543 83A I 222 4'h 114 41.1. 108 113Yz 343 515/Ie 151 5 127 30 13 Suffix HC—Fire Hydrant Fittings dimension'A'=25" Air Gaps and Elbows MODELA ORAIN OUTLET DIMENSIONS For 909,009,and 993 A B in mm in. mm in. mm Jb kg 909AGA '/V-1/2"009, 'h 13 21A 60 3'/ 79 0.625 0.28 %"009M2/M3 909AGC %11-1"009/909, 1 25 3'/4 83 47/ 124 1.5 0.68 B 1"-1'h"009M2 909AGF 1Y4"-2"009M1, 2 51 4% 111 6% 171 3.25 1.47 1'/4"-3"009/909, 2"009M2.4"-6"993 909AGK V-6"909, 3 76 6% 162 9% 244 6.25 2.83 811-101,909M1 A 909AGM 8"-10,1 909 4 102 7% 187 11'/ 286 15.5 7.03 909ELA ''/"-'h"009.3/"009M2/M3 - - - - - - - - 909ELC 3/"-1"009/909 - - 23/a 60 23/ 60 0.38 0.17 909ELF* lY4"-2"009M1, - - 3% 92 3% 92 2 0.91 B 1'/"-2"009/909, 2"009M2,4"-6"993 909EL.H* 2%"-3"009/909 - - - - - - - Vertical Epoxy coated Facility Name: Vintage Orchid Coffee Facility Address: 103 E 3rd St Arlington, WA 98223 Contract Info: Ben Brandfas Contact Phone: 520-301-7119 Equpment List: # Item Name QTY Make Model 1. POS 1 Square Register (1/4"=1') ��� 2. Coffee Espresso Machine t Nuova Simonelli Aurelia 2 grp 3 Undercounter Refrigerator t Avantco AU-27R-HC 27" e 4. Ice Maker t EUHOMY IM-02 7 5. 3 Compartment sink Regency 600B31014213 O e © 13 6. Hand Washing sink 1 Regency 600HS12SP 11 With drainboards on each side C-, s 7. Refridgerator 1 Avantco A-19R-HC 29 9 8. Employee Storage 1 Prepac WES-3264 9. Refrigerator sandwich prep 1 Avantco APT-48M-HC 4 10. Handwashing sink 1 Bathroom sink 12 3 11. Employee Bathroom 1 Bathroom Sink 61P 14 12. Customer Bathroom 1 7 13. Dry Good storage 1 Prepac WES-3264 f 14. Pitcher washing station 1 Espresso Parts BOOBMTWYUM 1(0 =door- /0 k 1 i M=qR Received cam 77 DEC 112023 'A/ l �— iGrease Interceptor Sizing Worksheet Facility Name: V i f%+A a C e c14►� Address: 103 E_ Suite No.: A Grease Interceptor(HGI)plumbing permit is required($165.00 fee). Contact the Pretreatment Technician(425-771-0237 ext. 1357) if you have any questions regarding this form. Dishwashers are not allowed to be connected to a HGI. • Food disposers are not allowed in a facility served by a HGI and must be disabled or removed. Solids must be screened out and placed in the solid waste container. Fixture Capacity in Cubic Fixture Capacity Drainage Load Flow Rate for Inches in Gallons (75% of Total a 2-Minute x W x D x no. of sinks Cu.In._231) Capacity) Drain Period #1 fU x x !bx = cA. =231= . al. x .75= 13,t, al. T2= m #2 x x x = CA. =231 = gal. x .75= gal. =2= 9PM #3 x x x = c.i. =231 = gal. x.75= gal. T 2= 9PM #4 x x x = c.i. -231 = gal. I x.75= gal. =2= 9PM • jry rc•.� ; d CD 'C' '« l t • 5 i ow Polo • r � � / .firloll •n ; � �' �. 'y �� .� 1 -�i" � � . ` `' � ` tip, � ,�j AP sh r' I ETA43 •" • �.in dff 1-10 dr '{ . ', IK •1 { Ci r TP4% .�1Dot S� ' N • .0 A If 1-% Ir Received r •- �� - Project: Date: Approval: Qty: Item#: 60OB31014213 f ; REGENCY Regency 3 Bowl Underbar Sink with Two Drainboards-60"x 18 3/4" Tables and Sinks •60OB31014213 1 i (( (I Technical Data Length 60Inches width 18 3/4Inches Held 33Inches Drainboard length 13Inches BovA Depth 10Inches Backsplash Height 3Inches Badaplash With Backsplash Bowl Frontto Back 141nches Bowl Left to Right 10Inches Compliances Commonwealth of Massachusetts Features Durable stainless steel construction Three 2"drains(11/2"IPS)with drain baskets included Galvanized legs with bullet feet • Deep bowls accommodate tall glasses and pitchers • Two drainboards aid in fast drying Certifications ®NSF Listed ®2023 Regency Tables&Sinks Technical Data Fasoma NSF LISWI a 1B Gauge Lq Construction GaNwdmd Sbeel Material Stalnles Steel Numberof Bowh 3 Bawls e Number of Compartments 3Compartments Number of Dralnbeards 2 Drainboards Stainless Steel Type Type 304 . Type BwSlnks 0 2023 Regency Tables&Sinks Plan View TOP FRONT SIDE • r � T r z• 3' o o T-�• _ 18%. / �` �_ y�771XY 0- 10" 12%" 30- 1 33' F-13"—f H 2" V r •, STYu F-16%a"—� TOP FRONT SIDE F 28-— —"+4"- —28" 2" !— — 60- —F _ ...........—...----- Y -•r 13"—1 i KY 2 'lG 571E" Notes&Details This 3-bowl bar sink comes standard with two 13"drainboards for efficient washing and drying of your barwa re.The deep,10" sink bowls accommodate all types of glasses,including pitchers!As an added convenience,itfeatures a 3"high backsplash to keep your bar better protected from accidental spills.This 3-bowl underbar sink has two holes punched on 4"centers. This sink offers a durable 18 gauge type 304 stainless steel construction along its top,bowls,and back.For maximum stability, it has 16-gauge galvanized steel legs with plastic bullet feet. 0 2023 Regency Tables&Sinks Project: Date: Approval: Qty Item#: 600FW412 REGENCY Regency Wall Mount Faucet with 4"Centers and 12"Swing Spout Plumbing and Hardware f600FW412 Mir 1 t • Technical Data Spout taeth 121nches Faucet Heist 5 7/B Inches CutridlIelype Ceramic �y Faucet Centers 41nches Carrfomla AB100 Compllant Feahres NSF Usted _- Finish Chrome _ - Fl w Rate 2 GPM Hwdlelype Lever MaOertal Brass Features 12"swing spout,2 GPM aerator 4"centers,1/2"NPS inlets Wall mounted base,attractive chrome-plated brass construction 140 degree maximum water temperature • Lever handle design Certifications �r ® NSF/AN5161&372 O 1/2"WaterConneedon a7�' CSA-C_US —_, c a ®NSF Usted ®2023 Regency Plumbing&Hardware Technical Data ' Mounting Style Wall Mounted YlmntIng Type Workboard spout C1ewwce 3 9/16 Inches Spout Type swing Ternperattse Rath♦ 140 Degrees Fahrenheit • Type Faucets water inlet sin 1/2 mrfies • Plan View • T e 5r%" { 3%." 3 %"NPSM i— .— 12' — 4- — Notes&Details This Regency wall mount faucet with 12"swing spout is an excellent choice when you need a reliable,affordable water fixture for your facility!Designed to be easy to install and easy to maintain,it's easy to see why Regency faucets area great solution for any business.Thanks to a 12"swing spout,this faucet delivers water exactly where you need it,and the moveable design lets you adjust it to fill multi-compartment sinks or maneuver around larger cooking vessels. Water exits the faucet through a 2 GPM aerator,which creates a soft flow pattern with minimal splashing.The faucet installs on your wall or sink backsplash on a pair of 4"centers and connects to the facility water lines with a set of 1/2"NPT inlets.The faucet body is made from chrome-plated brass that complements nearly any design aesthetic,and the water flow is controlled by a pair of simple lever handles.An installation kit is required for setup(sold separately). ®WARNING:This product can arpose you to chemicals lncludmg lead which are known to the State of California to muse mnoQ,birth defects.or other reprodudve harts For more Wonnation,go to ry.udSr.Zrn,rrx+.axr.. 0 2023 Regency Plumbing&Hardware Project: Date: Approval: Qty: Item#: 60OH512SP Regency 12"x 16"Wall Mounted Hand Sink with Gooseneck REGENCY Faucet and Side Splash Tables and Sinks i600HS12SP �1 Technical Data try, 12Inches Width 161nches Height 121nches Bowl Depth 4Inches Faucat Haft B Inches Bowl Front to Back 9lnches CorA Left mpliance Rat Cinches Compliances Commonwealth of Massachusetts Faucet Cerners 41nches Flow Rate 2GPM Features 8"gooseneck faucet included 18-gauge type 304stainless steel side splashes and awall mounted clip 20-gauge type 304 stainless steel Holes punched on 4"centers;8"backsplash Single 9"x 9"x 4"bowl includes 11/2"IPS drain baskets Certifications I NSF Listed ®2023 Regency Tables&Sinks Technical Data 1 Faucetlnduded g n kehx= NSF Listed Side Splashes 1 Gauge 20 Gauge Installation WW Wall Mounted Material Stainless Steel a Number of Co nInwbnents I Comparanent • Numberof Faucets 1 1 spoutlype Gooseneck Stainless5teeMpe TYce304 1 Type Hand Sinks Plan View TOP FRONT SH 12" ~4"+4"+4"� T � � T 2n --- t 8" I i 1" O ; O O 10" 3%R 14" I ( 2' T 9" 40 1 -4-9" H i---16" _ 1�n Notes&Details Keep your restaurant up to code without sacrificing space with this Regency HS-12-51P space saver hand sink with side splash. Each sink comes standard with a single 9"x 9"x 4"bowl and 8"high back and side splashes.Additionally,this hand sink has two holes punched on 4"centers to accept its included Regency 8"gooseneck faucet This sink offers an economical,20-gauge type 304 stainless steel construction along its top,bowl,and backspash,in addition to 18-gauge type 304stainless steel side splashes and a wall mounted clip.It comes standard with a 1 V2"IPS drain basket ®WARNING:This product ran awose You to chemkaals Including lead and Nickel.which are known to the State of Califomla to cause cancer.birth defects,or other reproducthAe harm For more Informatlom go to ®2023 Regency Tables&Sinks Project: Date: Approval: Qty: Item#: 60OGT25 r' REGENCY Regency 50 lb.25 GPM Grease Trap with 3"Non Threaded Connections Plumbing and Hardware t600GT25 a i r' Technical Data Len1th 271/B Inches width SB 5/8 Inches Hav,t 171/41nches Capacity 50It. Flow pay 25 GPM Inlet and Outlet Size 31nches �1 Material Sted Grease Traps Features • 50lb.capacity;25 GPM Includes external flow control fitting 3"non-threaded connections Steel construction with removable baffle • Dual handles help to pull the lid off Certifications Ay' PDI Certified 0 2023 Regency Plumbing&Hardware Plan View • TOPVIEW F 27%' T- 18%, ® Qjer FRONTSIDE - LEFTSIDE RIGHTSIDE W T • O 1>x� 1 2%' T _. i t--t Z7_ � 17' —1 �—25%- • BOTTOM VIEW Notes&Details Use this Regency 501b.25 GPM grease trap to keep your restaurant code-compliant and make it easy to remove harmful, greasy substances from drainage lines!The greasy byproducts that go down the drain of prep sinks,pot sinks,and commercial dishwashers are difficult to process and can cause environmental issues ifthey enter the sewer,septic field,or a nearby wastewater treatment facility.Local plumbing codes may require a grease trap on these and other appliances to prevent this from happening. This trap has a grease capacity of 50lb.and a flow rate of 25 GPM,with external flow control fitting and 3"non-threaded inlet/ outlet connections to install it on your drain lines.Its steel construction and removable baffle make cleanout easy.Additionally, the lid features two convenient pull handles to make accessingthe trap interior easier,too. ®WARNING This product can amuse You to dremlois Including lead,which are known to the State of California to cause carer,birth defects.or other reproducthe harm For more Information go to www.p65wamines,ca.g�. 1 1 J 0 2023 Regency Plumbing&Hardware I d3 E 3�� }• oe TA 1 ji Cot- - G�o 1 ne I I f Ntrt� : �'Zo�l1� "1�-�Q�r� fir►�1 GvV ?V,.4 '-'PEA- FOP, I � '�•I✓�rl�ib �c�via��� f� CITY OF ARLIh,GTON '� �+ ��► 3 �,f BUILDING DEPARTMENT APPROVED DATE BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR Received DEC 112023 to G-A �V Permit#: 5741 Permit Date: 12/14/23 Permit Type: COMMERCIAL PLUMBING Project Name: Vintage Orchid Coffee Applicant Name: Go Jo Plumbing Applicant Address: 10426 State Route 530 Applicant, City, State, Arlington,WA 98223 Zip: Contact: Maurice Toenyan Phone: 206-491-2270 Email: itisgojo@yahoo.com Scope of Work: Installation of 3 compartment sink, hand sink, floor sink,backflow, and grease interceptor for coffee shop Valuation: 7500.00 Square Feet: 0 Number of Stories: 1 Construction Type: VB Occupancy Group: A-2;Assembly ID Code: Permit Issued: Permit Expires: Form Permit Type: COMMERCIAL PLUMBING Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning THIRD STREET 230 COMMERCIAL 00529900101200 103 E 3RD ST ARLINGTON /SERVICES PROPERTIES LLC Plan Reviews Date Review Type Description Assigned To Review Status 12/14/2023 COMMERCIAL PLUMBING BUILDING In Review 12/14/2023 COMMERCIAL PW-ADMIN-GIS In Review PLUMBING 12/14/2023 COMMERCIAL PLUMBING PW-SEW-REV In Review COMMERCIAL PLUMBING APPLICATION Community&Economic Development City of Arlington-18204 59th Ave NE-Arlington,WA 98223-Phone(360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This includes commercial, tenant improvements, multi-family buildings, roof drains, and overflows, medical gas systems, commercial kitchens, grease traps and interceptors, sumps and cross connection backflow devices. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. SUBMIT THE FOLLOWING ELECTRONICALLY: El Plumbing plans or drawings.(Minimum plan size is 18"X 24"scale,1/4"scale for details.) El Fixture specifications and equipment(cut sheets)with locations. 0 Location and type of all backflow assemblies for each fixture. IN ADDITION TO ABOVE,SUBMIT THE FOLLOWING,IF APPLICABLE TO YOUR PROJECT: S Calculations for Grease Interceptor. ID Pipe size and location of sanitary and potable water systems. ID Riser diagram of waste,vent,and rain water systems,including sizes. ❑ Medical gas piping riser diagram,type of gas,storage room and size of piping. Type of Permit: ❑ New Installation ❑✓ Addition/Alteration/Repair ❑ Industrial Property Address: 103 E 3rd St Project Valuation: 7500.00 Lot#: Parcel ID No.: 00529900101200 Preferred Contact: O Owner 9 Contractor Installation of 3- comp sink, hand sink, floor sink, backflow preventer, and Project Description: Dr. Gurpreet S. Khurana Owner Name: Office No.: Email Address: 365gsk@gmail.com Cell No.: 425-358-8888 Mailing Address: 14205 SE 36th St#365 City: Bellevue State: WA Zip: 98006 Contractor Name: Go Jo Plumbing Office No.: 206-491-2270 Email Address: itisgOJo@yahoo.com Cell No.: 206-276-9758 Mailing Address: 10426 State Route 530 NE City: g State: Zip: Arlin ton WA 98223 L&I Contractor License Number: 6048855375 Expiration Date: March 21, 2024 REV1.2020 '�Jp Grim Page 1 of 3 PLUMBING PERMIT FEES(per fixture) Commercial plumbing permits are required to submit line drawings.A plan review fee of 65%per Table 4-6 for plumbing permits will be assessed at time of submittal.Includes two(2)inspections with permit. -Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration re air piping x $ 15.00 = Backflow Assembly 1 x $25.00 = 25.00 Base Plumbing Fee $25.00 $25.00 Bath Shower Combo x $ 15.00 = -Building Main Waste x $25.00 = Clothes Washer x 1 $15.00 = Dishwasher x $ 15.00 = Drinking Fountain x $ 15.00 = Floor Drains 1 x $15.00 = 15.00 Grease Interce for 1 x $75.00 = 75.00 Grease Trap x $25.00 = Hose Bibb x $ 15.00 = Icemaker Refri erator 1 x $ 15.00 = 15.00 Irrigation-per meter x $25.00 = Kitchen Sink&Disposal x $ 15.00 = Laundry Tray x $ 15.00 = Lavatory x $ 15.00 = Med Gas Pi in <-5 inlets outlets x 1 $ 60.00 = Med Gas Piping> 5 inlets/outlets(plus:5 5 x $5.00 = inlets outlets Miscellaneous-regulated by plumbing x $15.00 = code,not otherwise sped fiecl Pretreatment Interceptor x $ 15.00 = Re-inspection Fee all x $75.00 = Roof Drains x $ 15.00 = Shower(only) x $15.00 = Sink(bar,service,etc. 4 x $ 15.00 160.00 Toilets x $15.00 = Urinal x $15.00 = Vacuum Breakers x $25.00 = Water Heater x $25.00 = Water Heater-Tankless x $25.00 = Permit Fee Table 4-6;Plan Review Fee Processing/Technology Fee $25.00 Total $240.00 REV1.2020 Page 2 of 3 PROPOSED BUILDING USE ❑ New ❑ Restaurant ❑ Automotive Based ❑ Addition/Alteration ❑ Office ❑ Machine Shop ❑ Industrial ❑ Medical ❑✓ Other: Coffee Shop CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. ❑✓ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑✓ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ Swimming Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the plumbing system currently have a grease ❑ Yes No ❑ Don't Know interceptor? Does the plumbing system currently have an oil/water ❑ Yes ❑✓ No ❑ Don't Know separator? Is water used in the business process (washing,rinsing, Yes ❑ No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑✓ Yes ❑ No ❑ Don't Know 1 hereby certify that 1 am the ❑Owner, []Applicant" ❑Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained when complete. 1_11;;;���r- ;:;—�� Maurice Toenyan 12/8/2023 Signature Print Name Date SAVE PRINT REV1.2020 Page 3 of Facility Name: Vintage Orchid Coffee Facility Address: 103 E 3rd St Arlington, WA 98223 Contract Info: Ben Brandfas Contact Phone: 520-301-7119 Equpment List: P / # Item Name QTY Make Model 1. POS 1 Square Register (1/4"=1') ;:��r j 2. Coffee Espresso Machine 1 Nuova Simonelli Aurelia 2 grp 3 Undercounter Refrigerator 1 Avantco AU-27R-HC 27" I s 4. Ice Maker 1 EUHOMY IM-02 7 S. 3 Compartment sink 1 Regency 600B31014213 O 13 6. Hand Washing sink 1 Regency 600HS12SP � 6 With drainboards on each side 11 5 7. Refridgerator 1 Avantco A-19R-HC 29 i 9 8. Employee Storage 1 Prepac WES-3264 9. Refrigerator sandwich prep 1 Avantco APT-48M-HC 4 10. Handwashing sink 1 Bathroom sink 12 11. Employee Bathroom 1 Bathroom Sink 6-1) 4 12. Customer Bathroom 1 n 13. Dry Good storage 1 Prepac WES-3264 F 14. Pitcher washing station 1 Espresso Parts BOOBMTWYUM i S (v'e r.5e z l(o- Flo 5 f"o k 1 aas sq n LP - 1 Received L -! DEC 1-1, 2023 Grease Interceptor Sizing Worksheet Facility Name: V l n+a s e- Cyr c k i oL o P4 Address: 3A S+. Aw f ^r- v Suite No.: A Grease Interceptor(HGI)plumbing permit is required($165.00 fee). Contact the Pretreatment Technician(425-771-0237 ext. 1357) if you have any questions regarding this form. • Dishwashers are not allowed to be connected to a HGI. • Food disposers are not allowed in a facility served by a HGI and must be disabled or removed. Solids must be screened out and placed in the solid waste container. Fixture Capacity in Cubic Fixture Capacity Drainage Load Flow Rate for Inches in Gallons (75% of Total a 2-Minute (L x W x D x no. of sinks) (Cu.In._231) Capacity) Drain Period #1 !'i> x x ti x = c.i. =231 = . al. x.75= 13,6 =2= m #2 x x x = c.i. —231 = gal. x.75= gal. —2= 9Pm #3 x x x = c.i. —231 = gal. x.75= gal. —2= 9PM #4 x x x = cd. I =231 = gal. I x.75= gal. =2 9Pm Project: Date: Approval: Qty: _ Item#: 60OB31014213 i t REGENCY Regency 3 Bowl Underbar Sink with Two Drainboards-60"x 18 3/4" Tobles and Slni ►600B31014213 i - —G. . LLi t Technical Data Lwwh 60Inches Width Is 314Inches Height 331nches Drainboard Length 13 Inches Bo•A Depth Winches Baclaplash Height 31nches Badoplash with Backsplash Bowl Frontto Back 141nches Bowl Left to Right 10Inches Compliances Commonwealth of Massachusetts Features Durable stainless steel construction Three 2"drains(11/2"IPS)with drain baskets included Galvanized legs with bulietfeet • Deep bowls accommodate tall glasses and pitchers • Two drainboards aid in fast drying Certifications ®NSF Listed Received ®FC 112023 ®2023 Regency Tables&Sinks tV Technical Data Feabres NSF Listed • Gauge 18 Gauge g Leg Comhuction Galvanized Sled Material Stainless Steel Numbaof Bowls 3 Bowls Number of Compartments 3 Compartments Number of Dralnboart; 2 Drahboards g Stainless Steel Type Type 304 NXI Bar Sinks 0 2023 Regency Tables&Sims Plan View TOP FRONT SIDE 60- i za. —,4,: 28- r J2" 3- 0 0 ---- ---- ��" 18Y.." / ; �� lyy 1p- 33' h-13" Hi F1 30- 21 TOP FRONT SIDE 2" 1 - - 60" t-- 28' 4''- —28" H T -- - I% 3 0 0 - ---•- %. '0 —— *S -1835" /'/ ` - T 1Ys• 10. W-1 1 T s 1" 33" W. —13"—I 2N" iG■ t Notes&Details This 3-bowl bar sink comes standard with two 13"drainboards for efficient washing and drying of your barware.The deep,10" sink bowls accommodate all types of glasses,including pitchers!As an added convenience,itfeatures a 3"high backsplash to keep your bar better protected from accidental spills.This 3-bowl underbarsink has two holes punched on 4"centers. This sink offers a durable 18 gauge type 304 stainless steel construction along its top,bowls,and back.For maximum stability, it has 16-gauge galvanized steel legs with plastic bullet feet. 0 2023 Regency Tables&sinks Project: Date: Approval: Qty Item#: 600FW412 1 1 ; REGENCY Regency Wall Mount Faucet with 4"Centers and 12"Swing Spout ind Hordwaro • f600FW412 71r -=Z OW e r Technical Data - Spout ia49tl, 12 inches ti- .�(S Faucet Height 57/B Inches Car4ldgelype Ceramic Faucet Centers 4Inches Features _ r,.,a'a B100 Compliant - Finish Chrome Flo"Ralle 2 GPM Handlelype Lever maw" Brass Features 12"swing spout,2 GPM aerator 4"centers,1/2"NPS inlets • Wall mounted base,attractive chrome-plated brass construction • 140 degree maximum water temperature • Lever handle design Certifications ® NSF/ANSI61&372 O V2"Water Connection s1' CS/LC_US ®NSFLlsted 0 2023 Regency Plumbing&Hardware Technical Data k Mounyngstyle Wall Mounted Mounynslype Workboard Sport CWwa¢e 3 9/16Inches SpoutType Swing Twperattve Rathy 140 Degrees Fah.m It • Type Faucets WaWinlet Slm 1/2Inches • Plan View sr^ - j i I E 3%." vie^ 1 %"NPSM 4• Notes&Details This Regencywall mount faucet with 12"swing spout is an excellent choice when you need a reliable,affordable water fixture for your facility!Designed to be easy to install and easy to maintain,it's easy to see why Regency faucets area great solution for any business.Thanks to a 12"swing spout,this faucet delivers water exactly where you need it,and the moveable design lets you adjust it to fill multi-compartment sinks or maneuver around larger cooking vessels. Water exits the faucet through a 2 GPM aerator,which creates a soft flow pattern with minimal splashing.The faucet installs on your wall or sink backsplash on a pair of 4"centers and connects to the facility water lines with a set of 1/2"NPT inlets.The faucet body is made from chrome-plated brass that complements nearly any design aesthetic,and the water flow is controlled by a pair of simple lever handles.An installation kit is required for setup(sold separately). &MUM:This product can expose you to ci a nlcals Including leffi wfikh are known to the state of California to muse c ,,birth defects,or other reproductive hum For more Intormatlon go to www.o65waminmcagov. ®2023 Regency Plumbing&Hardware Project: Date: Approval: Qty: _ Item#: 600HS12SP Regency 12"x 16"Wall Mounted Hand Sink with Gooseneck REGENCY Faucet and Side Splash Tables and SfnkE 0600HSMP z i Technical Data Length 12 Indies Width 161nches Height 12 Inches - Bowl Depth 41nches Faucat He ft B Inches j Bowl Front to Back 91nches Bovd Left toRight 9lnches ComPllancxs Commonwealth of Massachusetts Faucet Centers 4Ir¢hes Flow Rate 2 GPM Features • 8"gooseneck faucet included • 18-gauge type 304 stainless steel side splashes and a wall mounted clip • 20-gauge type 304 stainless steel • Holes punched on 4"centers;8"backsplash • Single 9"x 9"x 4"bowl includes 11/2"1 PS drain baskets Certifications ®NSF Listed 0 2023 Regency Tables&Sinks Technical Data Faucet Included Features NSF Listed Side Splashes Gauge 20Gauge Yutallatfon Type Wall Mounted Material Stainless Steel a Number of Comportments ICompartment Numberof Faucets 1 SpWtType Goommck Stainless Steel Type Type 304 ly" Hand Sinks Plan View TOP FRONT SIDE 4" 4"+4"-I T 2" 8" O p o I1" 10" T 1 „ 3%* 14" O 2" T 9" Q - 4" 1 -� 9" ►--I I----16" Notes&Details Keep your restaurant up to code without sacrificing space with this Regency HS-12-SP space saver hand sink with side splash. Each sink comes standard with a single 9"x 9"x 4"bowl and 8"high back and side splashes.Additionally,this hand sink has two holes punched on 4"centers to accept its included Regency 8"gooseneck faucet This sink offers an economical,20-gauge type 304 stainless steel construction along its top,trawl,and backspash,in addition to 18-gauge type 304 stainless steel side splashes and a wall mounted clip.It comes standard with a 11/2"IPS drain basket ®WARNING TW product can expose you to chemicals Including Lead and NickeL which are known to the State of California to case cancer.birth defects,mother reproductive harm For more information,Soto �.phl5warni nesca.gov. 0 2023 Regency Tables&Sinks Project. Date: Approval: Qty: _ Item#: 60OGT25 1 ; REGENCY Regency 50 lb.25 GPM Grease Trap with 3"Non Threaded Connections Plumbing and Hardware 06000T25 1 • - • Technical Data lath 271/8Inches Width 19 5/e Inches H 17 va Inches Capacity 50lb. Flaw Rate 25 GPM Inlet and Outlet Size 31nches MaterM Steel Type Grease Traps Features 50lb.capacity;25 GPM Includes external flow control fitting 3"non-threaded connections Steel construction with removable baffle Dual handles help to pull the lid off Certifications PDI Certified ®2023 Regency Plumbing&Hardware Plan View • TOP VIEW 27%' T ® OJOT LEFT SIDE FRONTSIDE RIGHTSIDE 31' • O 3%-i O � • 171t' 12� T 2%' r---- ST —1 • �--25%' —i • BOTTOM VIEW 2%' Notes&Details Use this Regency 501b.25 GPM grease trap to keep your restaurant code-compliant and make it easy to remove harmful, greasy substances from drainage lines!The greasy byproducts that go down the drain of prep sinks,pot sinks,and commercial dishwashers are difficult to process and can cause environmental issues if they enter the sewer,septic field,or a nearby wastewater treatment facility.Local plumbing codes may require a grease trap on these and other appliances to prevent this from happening. This trap has a grease capacity of 50 lb.and a flow rate of 25 GPM,with external flow control fitting and 3"non-threaded inlet/ outlet connections to Install it on your drain lines.Its steel construction and removable baffle make cleanout easy.Additionally, the lid features two convenient pull handles to make accessing the trap interior easier,too. ®WARNMG This product can e,mose you to chemicals Including lead.W*Jch are known to the State of Calftnla to cause cases,birth defects,or other reproductive harm For more Information Soto �p65waml ca. 0 2023 Regency Plumbing&Hardware ES-009 Engineering Specification Job Name Vintage Orchid Coffee Contractor Go Jo Plumbing 103 E 3rd St. Job Location Approval Engineer Contractor's P.O. No. Approval Representative Series 009 Reduced Pressure Zone Assemblies I j t/411_211 x; It is illegal to use this product in any plumbing system providing water for human consumption,such as drinking or dishwashing, in the United States.Before installing standard material product, consult your local water authority,building and plumbing codes. Series 009 Reduced Pressure Zone assemblies are designed 009M2-QT-FS to protect potable water supplies in accordance with national plumbing codes and water authority requirements.Specifically, the series protects drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements for non-potable service applications such as irrigation,fireline,or industrial processing. Test Cock No.3 Test Cock No.4 The series features two in-line,independent check valves, Ball Type captured springs,and replaceable check seats with an Test Cocks intermediate relief valve. Its compact modular design facilitates Test Cock maintenance and assembly access.Sizes 1/4"to 1"shutoffs No.2 , have tee handles. Second Series 009 assemblies of sizes 1h"to 2"include a flood sensor i First Check Check to detect excessive water discharges from the relief valve,The Module Module sensor is installed on the assembly exterior and does not alter Assembly y Assembly assembly functions or certifications.The sensor relays a signal that triggers notification to facility who can take corrective action,thus '' avoiding the possibility of ruinous flooding and costly damage. R.P.Zone Water Outlet An add-on connection kit is required to activate the flood Relief Valve Assembly sensor.Without the connection kit,the sensor is a passive component that has no communication with any other device. (For more information,download RP/IS-009.) Use of the flood sensor does not replace the need to comply Features with all required instructions,codes, and regulations related to installation, operation, and maintenance of this product, • Single access cover and modular check construction including the need to provide proper drainage in the event of for ease of maintenance a discharge. • Top entry to all internals for immediate accessibility Watts®is not responsible for the failure of alerts due to • Captured springs for safe maintenance connectivity or power issues. • Internal relief valve for reduced installation clearances MENEM • Replaceable seats for economical repair • Bronze body construction for durability(V4"—2") The information contained herein is not intended to replace the • Ball valve test cocks — screwdriver slotted(1/4"—2") full product installation and safety information available or the experience of a trained product installer.You are required to • Large body passages provides low pressure drop thoroughly read all installation instructions and prodtfa IV@d • Compact,space saving design information before beginning the installation of this product. • No special tools required for servicing Inquire with governing authorities for local installation-^ " " ^^^" • Sensor on the relief valve for flood detection(12"—2") requirements. Walls product specifications In U.S.custorrary urucs and metric are change and are provided for onstr cti only.Far precise measurements, please contact tNatb;Technical Service.Walls reserves the fight in change ar modify product design,construction,specifications,or materials with- out prar notice and witirout incurring any obligation to make such dmnges and modifications on Watts products prevlows or subsequently sold. Specification Pressure/Temperature A Reduced Pressure Zone assembly shall be installed at each Suitable for supply pressure up to 175 psi(12.1 bar) potential health hazard location to prevent backflow due to Water temperature: 33°F—180°F(0.5°C—75°C) backsiphonage and/or backpressure.The assembly shall consist of an internal pressure differential relief valve located in a zone Standards between two positive seating check modules with captured USC springs and silicone seat discs.Seats and seat discs shall be replaceable in both check modules and the relief valve.There ASSE No. 1013 shall be no threads or screws in the waterway exposed to line AWWA C511-92 fluids.Service of all internal components shall be through a CSA B64.4 single access bronze cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation IAPMO File No. 1563 valves,four resilient seated test cocks,and an air gap drain fitting.The assembly shall meet the requirements of USC;ASSE Approvals Std. 1013;A+AM+A Std.C511-92;CSA 136.1.4. Shall be a Watts® pssry Series 009,and shall include a sensor on the relief valve for flood G o`Ooedetection. U SN USC-FCCCHR Model/Option 1013 t'i Ug Prefix: ASSE,AWWA,CSA, IAPMO U —Union connections(For more information Approved by the Foundation for Cross-Connection Control and download ES-0009 at watts.com.) Hydraulic Research at the University of Southern California Suffix: UL Classified 3/4"—2" AQT — Elbow fittings for 360'rotation(34"—2") (LF models only except 009M3LF) FS — Flood detection sensor(1/2"—2') Insulated Enclosure HC — 212" Inlet/outlet fire hydrant fitting(2") The WattsBox insulated enclosure is available for Series 009. LF — Without shutoff valves For more information download ES-WB at watts.com. PC — Internal polymer coating QT — Quarter-turn bail valves S — Bronze strainer SH — Stainless steel ball valve handles Materials Bronze body construction,silicone rubber disc material in the first and second check plus the relief valve.Replaceable polymer check seats for first and second checks. Removable relief valve seats.Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional bronze union inlet and outlet connections,specify prefix U ('/2"—2").Series 009QT furnished with quarter turn,full port, resilient seated, bronze ball valve shutoffs. Dimensions — Weight Call customer service V you need assistance with technical details. 1/411 —3/8u 1`211 —2n 0 C N N '� i 0 B - L __ — M — - - A M - - A — MODEL DIMENSIONS A B C D L M N in. in. mm in. mm in. mm M. mm in. mmk33AB mm m. mm Ib kg 114 10 250 4% 117 33A 86 1Y4 32 5Yz 140 60 214 64 5 2 ?5 10 250 4% 117 3% 86 11/a 32 5% 140 60 2Yz 64 5 2 1/2 10 250 57A 149 3% 86 21h 64 536 140 70 2Ya 57 5 2 3/4 103/4 273 6Ya 159 N 89 21A 70 63A 171 81 23/a 70 6 3 1 14Yz 368 6Ya 159 3 76 3Ya 83 911 241 95 3 76 12 5 11 17% 441 63iA 169 3h 89 3Ya 83 11% 289 47/16 113 3Ye 89 15 6 1 Ye 17'/e 454 6- 169 31h 89 3Ya 1 83 11'A 283 47h 124 4 102 16 7 2 21% 543 83/a 222 4Ya 114 4Ya 1 108 131h 343 515h6 151 1 5 127 30 1 13 Suffix HC-Fire Hydrant Fittings dimension'A'=25' Air Gaps and Elbows MODEL StZE DRAIN OUTLET DIMENSIONS WEIGHT A Fbr 909,009,and 9M A B -T in. mm in. mm in. mm Ib kg 909AGA '/a"—'h"009, 1h 13 ZIA 60 3'/6 79 0.625 0.28 3/a"009M21M3 909AGC Yd'-1"0091909, 1 25 3Ya 83 47A 124 1.5 0.68 B 1"-1 h"009M2 909AGF 1'/a''-2"0091V11, 2 51 4% 111 63/ 171 3.25 1.47 1'/4"-3"009/909, 2"009M2.4"-6"993 909AGK 4"4"M. 3 76 6% 162 95/a 244 6.25 2.83 8"-10"909M1 -- A 909AGNI 8"-10"909 4 102 7% 187 11'/ 1 286 15.5 7.03 909ELA '/4"—'h"009.W 009M2/M3 — — — — — — — — 909ELC "-1"009/909 — — 23/a 60 2% 60 0.38 0.17 909ELFI 1'/a"-2"009M1, — — 3% 92 3% 92 2 0.91 � B 1'/a''-2"009/909, 2"009M2,4"-6"993 909ELH` T/P-3"009/909 Vertical Epoxy coated CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 103 E 3RD ST Permit#: 5741 PERMIT EXPIRES 180 DAYS AFTER Parcel#:00529900101200 DATE OF ISSUANCE. Scope of Work: Installation of 3 compartment sink,hand sink,floor sink,backflow, Valuation: 7500.00 and grease interceptor for coffee shop OWNER APPLICANT CONTRACTOR THIRD STREET ARLINGTON Go Jo Plumbing Go Jo Plumbing PROPERTIES LLC 915 118TH AVENUE SE 10426 State Route 530 10426 State Route 530 BELLEVUE,WA 98005 Arlington,WA 98223 Arlington,WA 98223 206-491-2270 LIC:GOJOPJP787PU EXP: 10/31/2024 LIC:604 885 375 EXP:03/31/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL PLUMBING CODE YEAR: 2018 STORIES: 1 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: A-2;Assembly BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your s es tax return form a ded City of Arlington#3101. 01/05/2024:� A plica t Signature Date Building Official Date CONDITIONS SEE REDLINED DRAWINGS FOR ADDITIONAL REQUIREMENTS.ADHERE TO APPROVED PLANS.CONTACT THE WASTEWATER DEPARTMENT FOR DISCHARGE AGREEMENT INFORMATION(WASTEWATER DEPARTMENT PHONE NUMBER 360-403-3526).APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 01/05/2024 Plumbing Commercial Plan Review $141.84 01/05/2024 Processing/Technology $25.00 01/05/2024 Backflow Assembly $25.00 01/05/2024 Sink(bar,service,etc.) $45.00 01/05/2024 Credit Card Service $7.11 Total Due: $243.95 Total Payment: $243.95 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Date: 05/26/2026 Permit#: 5741 Permit Date: 12/14/2023 Review Date: 12/22/2023 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 01/12/2024 Scheduled Time: 00:00 Completed Date: 12/28/2023 Description: A discharge agreement is required. Class 2. SB Review Status: Approved with Conditions Assigned To: PW-SEW-REV Time In: 00:00 Time Out: 00:00 Hours: 0.2 Notes 12/28/2023 Discharge agreement is required. Property Information Parcel#: 00529900101200 THIRD STREET ARLINGTON PROPERTIES LLC THIRD STREET ARLINGTON PROPERTIES LLC 915 118TH AVENUE SE 103 E 3RD ST BELLEVUE,WA 98005 Zoning: 230 COMMERCIAL/ SERVICESLot: Block: Permit#: 5741 Permit Date: 12/14/23 Permit Type: COMMERCIAL PLUMBING Project Name: Vintage Orchid Coffee Applicant Name: Go Jo Plumbing Applicant Address: 10426 State Route 530 Applicant, City, State,Arlington,WA 98223 Zip: Contact: Maurice Toenyan Phone: 206-491-2270 Email: itisgojo@yahoo.com Scope of Work: Installation of 3 compartment sink, hand sink, floor sink, backflow, and grease interceptor for coffee shop Valuation: 7500.00 Square Feet: 0 Number of Stories: 1 Construction Type: VB Occupancy Group: A-2;Assembly ID Code: Permit Issued: 01/10/2024 Permit Expires: 07/08/2024 Form Permit Type: COMMERCIAL PLUMBING Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning THIRD STREET 230 COMMERCIAL 00529900101200 103 E 3RD ST ARLINGTON SERVICES PROPERTIES LLC / Contractors Contractor Primary Contact Phone Address Contractor Type License License# Go Jo Plumbing 10426 State Route PLUMBING L&I GOJOPJP787PU 530 CONTRACTOR Go Jo Plumbing 10426 State Route PLUMBING COA 604 885 375 530 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 02/22/2024 C19.PLUMBING Complete-BG 02/23/2024 02/23/2024 BUILDING Approved FINAL C08.PLUMBING Please call on the way,520- O1/10/2024 ROUGH-IN 301-7119 01/11/2024 01/11/2024 BUILDING Approved Plan Reviews Datc Review Type Description Assigned To Review Status COMMERCIAL Provide trapped drain with cup below RPBA for testing Approved with 12/22/2023 PLUMBING requirements BUILDING Conditions 12/22/2023 COMMERCIAL No comments,LT&KS PW-ADMIN-GIS Approved PLUMBING COMMERCIAL Approved with 12/22/2023 PLUMBING A discharge agreement is required.Class 2.SB PW-SEW-REV Conditions COMMERCIAL No comments for this review. 12/22/2023 PLUMBING Inspection after installation is required PW-WAT-REV Approved Gus Fees Fee Description Notes Amount Plumbing Commercial Plan Review Table 4-1 $141.84 Processing/Technology $25.00 Backflow Assembly $25.00 Sink(bar,service,etc.) $45.00 Credit Card Service $7.11 Total $243.95 Attached Letters Date Letter Description 01/05/2024 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 01/04/2024 XBP Conf: $236.84 162338524 01/04/2024 Maurice Toenyan 162338524 $7.11 Outstanding Balance $0.00 Uploaded Files Date File Name 01/11/2024 18168745-20231226 BLD5741 ApprovedPlans.pdf 01/10/2024 18155012-20240105 BLD5741 ApprovedPermitDocuments.pdf 01/10/2024 18155013-20240110 BLD5741 IssuedPermit.pdf Date: 05/26/2026 Permit#: 5741 Permit Date: 12/14/2023 Review Date: 12/22/2023 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 01/12/2024 Scheduled Time: 00:00 Completed Date: 12/26/2023 Description: Provide trapped drain with cup below RPBA for testing requirements Review Status: Approved with Conditions Assigned To: BUILDING Time In: 00:00 Time Out: 00:00 Hours: 0.5 Notes 12/26/2023 Provide trapped drain with cup below RPBA for testing requirements Property Information Parcel#: 00529900101200 THIRD STREET ARLINGTON PROPERTIES LLC THIRD STREET ARLINGTON PROPERTIES LLC 915 118TH AVENUE SE 103 E 3RD ST BELLEVUE,WA 98005 Zoning: 230 COMMERCIAL/ SERVICESLot: Block: