Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17216 51st Ave Ne Ste 110_BLD5753_2026
i COMMERCIAL PLUMBING APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This includes commercial, tenant improvements, multi-family buildings, roof drains, and overflows, medical gas systems, commercial kitchens, grease traps and interceptors, sumps and cross connection backflow devices. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. SUBMIT THE FOLLOWING ELECTRONICALLY: El Plumbing plans or drawings. (Minimum plan size is 18"X 24"scale, 1/4"scale for details.) El Fixture specifications and equipment(cut sheets) with locations. 0 Location and type of all backflow assemblies for each fixture. IN ADDITION TO ABOVE,SUBMIT THE FOLLOWING,IF APPLICABLE TO YOUR PROJECT: ❑ Calculations for Grease Interceptor. ❑ Pipe size and location of sanitary and potable water systems. ❑ Riser diagram of waste,vent,and rain water systems,including sizes. ❑ Medical gas piping riser diagram,type of gas, storage room and size of piping. Type of Permit: ❑ New Installation 0 Addition/Alteration/Repair ❑ Industrial Property Address: 17216 51 ST AVE N E Project Valuation: $60,170.00 Lot#: Parcel ID No.: 31052100400100 Preferred Contact: O Owner O Contractor Project Description: TENANT 48 TI SMARTCAP ARLINGTON AIRPORT INDUSTRAIL PARK 206-619-4472 Owner Name: QOZB LLC Office No.: Email Address: BRITTNEY@SMARTCAPGROUP.COM Cell No.: Mailing Address: 8201 164TH AVE NE STE 110 City: REDMOND State: WA Zip: 98052 Contractor Name: WOLFE PLUMBING INC Office No.: 360-794-8621 Email Address: Jens@WOIfepI.com Cell No.: Mailing Address: 832 80TH ST SW City: EVERETT State: WA Zip: 98203 L&I Contractor License Number: WOLFEP1033CJ Expiration Date: 01/26/2025 REV1.2020 Page 1 of 3 PLUMBING PERMIT FEES (per fixture Commercial plumbing permits are required to submit line drawings.A plan review fee of 65%per Table 4-6 for plumbing permits will be assessed at time of submittal.Includes two (2) inspections with permit. Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee $ 25.00 $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste x $ 25.00 = Clothes Washer x $ 15.00 = Dishwasher 1 x $ 15.00 = 15.00 Drinking Fountain 1 x $ 15.00 = 15.00 Floor Drains 4 x $ 15.00 = 60.00 Grease Interceptor x $ 75.00 = Grease Trap x $ 25.00 = Hose Bibb x $ 15.00 = Icemaker/Refri erator 1 x $ 15.00 = 15.00 Irrigation-per meter x $ 25.00 = Kitchen Sink&Disposal 1 x $ 15.00 = 15.00 Laundry Tray x $ 15.00 = Lavatory 2 x $ 15.00 = 30.00 Med Gas Pipin <- 5 inlets/outlets x $ 60.00 = Med Gas Piping> 5 inlets/outlets (plus <_ 5 x $ 5.00 = inlets outlets Miscellaneous -regulated by plumbing x $ 15.00 = 15.00 code,not otherwise specified Pretreatment Interceptor x $ 15.00 = Re-inspection Fee all x $ 75.00 = Roof Drains x $ 15.00 = Shower (only) 2 x $ 15.00 = 30.00 Sink bar, service, etc. 1 x $ 15.00 = 15.00 Toilets 2 x $ 15.00 = 30.00 Urinal 2 x $ 15.00 = 30.00 Vacuum Breakers x $ 25.00 = Water Heater 1 x $ 25.00 = 25.00 Water Heater-Tankless x $ 25.00 = Permit Fee 320.00 Table 4-6; Plan Review Fee Processing/Technology Fee $25.00 Total REV1.2020 Page 2 of 3 PROPOSED BUILDING USE ❑ New ❑ Restaurant ❑ Automotive Based ✓❑ Addition/Alteration ❑ Office ❑ Machine Shop ❑ Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. ✓❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ✓❑ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ Swimming Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the plumbing system currently have a grease ❑ Yes ✓❑ No ❑ Don't Know interceptor? Does the plumbing system currently have an oil/water ❑ Yes ✓❑ No ❑ Don't Know separator? Is water used in the business process (washing,rinsing, ❑ Yes ✓❑ No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑ Yes ✓❑ No ❑ Don't Know I hereby certify that I am the ❑Owner, ❑Applicant, QContractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. A final inspection and approval shall be obtained when complete. JEN SCHARPP 12/29/2023 nature Print Name Date g e SAVE PRINT REV1.2020 Page 3 of 3 GENERAL NOTES SYMBOLS ABBREVIATIONS 1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL, GENERAL PIPE SYMBOLS ABV ABOVE FPM FEET PER MINUTE OVERFLOW DRAIN/DECK DRAIN STRUCTURAL, CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S AD AREA DRAIN FPS FEET PER SECOND OPD OVER PRESSURE DEVICE DIMENSIONS (VERIFY). ARCHITECTURAL BACKGROUND C TOP PIPE CONNECTION AFF ABOVE FINISHED FLOOR FS FLOOR SINK OPNG OPENING AHJ(THIN LINE) BFF BELOW FINISHED FLOOR FU FIXTURE UNITS PD PRESSURE DROP, PLANTER DRAIN AUTHORITY HAVING JURISDICTION FT FEET P PUMP 2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, 7 BOTTOM PIPE CONNECTION BFP BACKFLOW PREVENTER G GAS (LOW PRESSURE) POC POINT OF CONNECTION ETC. OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. BOH BACK OF HOUSE GAL GALLONS PRV PRESSURE REDUCING VALVE NEW PIPING (HEAVY LINE) __o PIPE TURNING UP BP BOOSTER PUMP GD GARAGE DRAIN PRESSURE RELIEF VALVE 3. CODES: COMPLETE INSTALLATION OF THE PLUMBING SYSTEM SHALL BE PER THE APPLICABLE BUILDING, BT BATHTUB GM GAS METER PS PUMPED STORM DRAINAGE MECHANICAL, ENERGY, PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL EXISTING PIPING (THIN LINE) O PIPE TURNING DOWN/DROP BTUH BRITISH THERMAL UNIT PER HOUR GPG GRAINS PER GALLON PSIG POUNDS PER SQUARE INCH GAUGE z z C COMMON GPM GALLONS PER MINUTE PSD PUMPED STORM DRAINAGE o_ O_ N 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR PIPE CAP CAP CAPACITY GV GATE VALVE PSS PUMPED SANITARY SEWER a LOCATING AND ROUTING ALL EQUIPMENT, PIPING, ETC. EXISTING WORK TO BE REMOVED CB CATCH BASIN OWE GYPSUM WALLBOARD PSW PUMPED SANITARY WASTE PIPE PLUG CD CONDENSATE DRAIN GWH GAS WATER HEATER PW PUMPED WASTE U A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL OFF CAPPED FOR FUTURE HB HOSE BIBB RD ROOF DRAIN w B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING, LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND - - MATCHLINE OR PROPERTY LINE CFM CUBIC FEET PER MINUTE HD HEAD REF REFERENCE OTHER TRADES WORK. '� UNION CI CASTIRON HDR HUB DRAIN RPBP REDUCED PRESSURE BACKFLOW C. INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT DUCT SIZING EXCHANGE, RELOCATING, ETC. CLG CEILING, COOLING HEDV HOSE END DRAIN VALVE PREVENTER AS REQUIRED FOR A COMPLETE OPERATING MECHANICAL SYSTEM. CONNECTION TO EXISTING �� FLANGE CLW CLOTHES WASHER HORIZ HORIZONTAL RPM REVOLUTIONS PER MINUTE D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. CO CLEANOUTS HP HORSEPOWER S SINK WYE STRAINER COMB C OMBUSTION HP CW HIGH PRESSURE COLD WATER SCH SCHEDULE 5. PLUMBING CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL PLUMBING EQUIPMENT CONT CONTINUE, CONTROL HW HOT WATER SOW SOFTENED COLD WATER Q WITHIN THE STRUCTURE. SECTION IDENTIFICATION WYE STRAINER WITH CAPPED HOSE CONTR CONTRACTOR HWC HOT WATER RE-CIRCULATION SD STORM DRAIN END BLOWDOWN VALVE COTG CLEANOUTS TO GRADE HWCP HOT WATER CIRCULATION PUMP SEP SEWAGE EJECTOR PUMP 6. ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO INDICATES DIRECTION OF CUTTING CP CIRCULATING PUMP HWR HOT WATER RETURN SF SQUARE FOOT O BEGINNING OF CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. VERIFY PLANE BALL VALVE CV CHECK VALVE HWST HOT WATER STORAGE TANK SGSV SEISMIC GAS SHUTOFF VALVE z ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. CW COLD WA LETTER INDICATES SECTION BALL VALVE D DIAMETER CW INDUSTRIAL COLD WATER SO STORM OVERFLOW TER HX HEAT EXCHANGER SH SHOWER 7. ROOF PENETRATIONS: SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, ROOF CURB, ROOF DRAIN, OVERFLOW DB DRY BULB, DECIBEL ID INDIRECT DRAIN, INSIDE DIAMETER SP STATIC PRESSURE/SUMP PUMP DRAINS AND VTR DETAILS. A (NO. INDICATES DETAIL) � � GLOBE VALVE DF DRINKING FOUNTAIN IE INVERT ELEVATION SR SUDS RELIEF C:�8. PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL DFU DRAIN FIXTURE UNITS IHW INDUSTRIAL HOW WATER SS STAINLESS STEEL/SANITARY SEWER P-3 P-3 SHEET NUMBER WHERE SECTION IS DI DUCTILE IRON IN INCH SSS SIDE SANITARY SEWER FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. ��� CHECK VALVE DIM DIMENSION KS KITCHEN SINK DRAWN STD STANDARD 9. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL SHEET NUMBER WHERE SECTION IS DIN DOWN KW KILOWATT SQ SQUARE AROUND PENETRATIONS IN AIR PLENUMS. fir- BALANCING OR PLUG VALVE DS DOWN SPOUT L LONG, LENGTH TD TRENCH DRAIN TAKEN DWG DRAWING LAV LAVATORY TMV THERMOSTATIC MIXING VALVE 10. LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER BUTTERFLY VALVE (E) EXISTING LB POUND TP TRAP PRIMER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. ELF EFFICIENCY M WATER METER TYP TYPICAL DETAIL IDENTIFICATION �� EQUI ELECTRIC MBH THOUSAND BTU PER HOUR UH UNIT HEATER 11. CABLE TRAYS: PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF FLEXIBLE CONNECTION IN PIPING EQUIV EQUIVALENT MECH MECHANICAL URN UNLESS OTHERWISE NOTED 6" ABOVE AND TO THE SIDE OF CABLE TRAYS. # DETAIL NUMBER EWC ELECTRIC WATER COOLER MCA MIN. CIRCUIT AMPACITY UR URINAL Opp JAC/r EWH ELECTRIC WATER HEATER MOCP MAX. OVER CURRENT PROTECTION V VENTS 12. MOTORS: COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. #DRAWING/SHEET NUMBER ^^ EXT EXTERIOR, EXTERNAL MPG MEDIUM PRESSURE GAS VTR VENT THRU ROOF :.��0 9,1,,y 00� �/ � PRESSURE REDUCING VALVE (PRV) F FAHRENHEIT MTD MOUNTED W WASTE, WATT, WIDE PRV FCO FLOOR CLEANOUTS (N) NEW WC WATER CLOSET _ 13. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO FD FLOOR DRAIN NO NORMALLY CLOSED WOO WALL CLEANOUTS ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK pp FDC FIRE DEPARMENT CONNECTION NO NORMALLY OPEN WHD WALL HYDRANT OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. �lil AUTOMATIC CONTROL VALVE, 2-WAY O EQUIPMENT ��� FF FINISHED FLOOR OD OUTSIDE DIMENSION/DIAMETER WM WASHING MACHINE � /1�� WSFU WATER SUPPLY FIXTURE UNITS OVAL ' COORDINATION REQUIREMENTS FLR FLOOR po0O0 TYPICAL EQUIPMENT DESIGNATION � AUTOMATIC CONTROL VALVE, 3-WAY 2g 1. IRRIGATION SYSTEM: COORDINATE IRRIGATION WATER DEMAND, MINIMUM WATER PRESSURE REQUIREMENTS & 1$ CONTROL CABINET LOCATIONS WITH IRRIGATION CONTRACTOR. HWCP-1 ID RELIEF VALVE 2. GAS: CONTRACTOR/GAS COMPANY SHALL FINALIZE GAS METER AND GAS SERVICE LOCATIONS. INSTALL SEISMIC GAS SHUT OFF VALVE PER GAS COMPANY REGULATIONS. PIPING BALANCING/MEASURING VALVE CONTRACTOR SUBSTITUTIONS & R EVI S I O N S 3. UTILITIES: COORDINATE WITH SITE UTILITY CONTRACTOR AND CIVIL DRAWINGS FOR UTILITY CONNECTIONS AND EXTENSIONS. W- WASTE BELOW GRADE r\ REDUCER o PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING o j +. ROOF DRAINAGE: COORDINATE WITH GENERAL CONTRACTOR FOR ROOF DRAIN AND OVERFLOWS, SCUPPER W WASTE ABOVE GRADE DIRECTION OF FLOW WORK. FOR EQUIPMENT THAT IS SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS, THE MANUFACTURER'S PUBLISHED z z y O 3 O w DRAINS, AND CONDENSATE DRAINS. DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION. ENGINEERING COSTS FOR REVISING MEP PLANS Q N a PW PUMPED WASTE A SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION PROPOSAL. CONTRACTOR TO COORDINATE WITH ENGINEER AND w = a T. PLUMBING FIXTURES & EQUIPMENT: COORDINATE EXACT LOCATION OF ALL PLUMBING FIXTURES & EQUIPMENT PIPE ANCHOR DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS. CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH Q WITH ARCHITECTURAL AND OTHER TRADES DOCUMENTS. IW INDIRECT WASTE UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. 6. PIPING: COORDINATE EXACT LOCATION OF ALL STRUCTURAL FRAMING & FOOTINGS AND FINALIZE THE EXACT SS SANITARY SEWER ABOVE GRADE - PIPE ALIGNMENT GUIDE ROUTING OF ALL PIPES WITH STRUCTURAL ENGINEER AT THE SITE PRIOR TO AND DURING THE CONSTRUCTION. -SS- SANITARY SEWER BELOW GRADE PIPE SUPPORT COORDINATE UNDER GRADE PIPING & FOUNDATION DRAINAGE PIPING WITH CIVIL ENGINEER. IPS SCOPE OF WORK � 7. ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS, IGNITION DEVICES, DRIVES, ETC. SHALL RL VENT RAIN LEADER Oc VALVE STATION OR ASSEMBLY ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND VD ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. ORL OVERFLOW RAIN LEADER INDIRECT DRAIN, PIPE TO DRAIN ID PROVIDE WATER SUPPLY AND SANITARY SEWER FOR NEW TENANT. m 8. APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT CD CONDENSATE DRAIN LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, POLLUTION, POINT OF CONNECTION Z ENVIRONMENTAL, SEISMIC, APPLICABLE CODES AND REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH - COLD WATER (CW) Y MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THE BID DOCUMENTS. HOT WATER (HW), POTABLE, 120'F 9. FIRE PROTECTION: CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN RD OD ROOF DRAIN, OVERFLOW DRAIN 7 COMPLIANCE WITH NFPA AND LOCAL CODES. PROVIDE DESIGN, PERMITS, MATERIALS, INSTALLATION, TESTING - -- -140 HOT WATER, POTABLE, m AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM. LOCATION OF ALL PIPING TO BE COORDINATED WITH TEMPERATURE OTHER THAN 120'F ' OTHER TRADES. ® ❑o FLOOR DRAIN y HOT WATER CIRCULATING (HWC), fr a 10. PRIOR TO PIPING INSTALLATION: PLUMBING CONTRACTOR TO COORDINATE PIPING LAYOUT WITH ALL OTHER POTABLE, 120'F Q o TRADES. HOSE BIBB d w z --- 140 HOT WATER CIRCULATING, POTABLE, F- _ 11. ACCESS: COORDINATE ALL ACCESS LOCATIONS WITH GENERAL CONTRACTOR AND ARCHITECT TO ENSURE ALL TEMPERATURE OTHER THAN 120'F Q Q E5 m m REQUIRED ACCESS HATCHES, ACCESS PANELS & ACCESS COVERS ARE PROVIDED. `r BREAK IN PIPING OR DUCTWORK C)Q U) m FOE FUEL OIL FILL w¢ z 12. PROVIDE & INSTALL WATER TIGHT SEALS FOR ANY PIPING PENETRATING THE EXTERIOR FOUNDATION WALLS OR GAS METER ¢?M SLABS. FOS FUEL OIL SUPPLY Z) =p o O 13. ANY DISCREPANCIES SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. 0 O� FOR FUEL OIL RETURN INLINE WATER METER Z O O O d3wa G z 14. PROVIDE & INSTALL FIRE PROOFING FOR ALL PIPING PENETRATING FIRE BARRIER WALLS OR FLOOR SLABS. FOV FUEL OIL VENT PUMP az.00 -RV- RELIEF VENT cod 9Q PRESSURE GAGE DRAWING INDEX < Z z G LOW PRESSURE NATURAL GAS Q MPG MEDIUM PRESSURE NATURAL GAS THERMOMETER ~Z Z IRR IRRIGATION (NON POTABLE) tP/T PRESSURE/TEMPERATURE INCLUDED IN SET Q00 Vl Z TEST PORT W �a�I�D� REDUCED PRESSURE BACKFLOW w n Q Q DISINFECTION OF PREVE"TER RPBP O Z �o � POTABLE WATER SYSTEM NOTE TO CONTRACTOR ---XDCVA DOUBLE CHECK VALVE ASSEMBLY z DCVA � CATCH BASIN DW DESCRIPTION f� IIIIIIIIIIIIIIIIIIII TRENCH DRAIN C DESCRY TION REI JOB #:478-041 PO.O LEGEND, GENERAL NOTES, AND DRAWING INDEX X 1. NEW OR REPAIRED POTABLE WATER SUPPLY SYSTEMS SHALL BE DISINFECTED PRIOR TO ��i EMERGENCY GAS SHUT-OFF VALVE P0.1 PLUMBING NOTES AND TABLES X USE PER AUTHORITY HAVING JURISDICTION. PO.2 PLUMBING CALCULATIONS & SCHEDULES X DATE: 12/29/2023 DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL PO.3 PLUMBING SCHEDULES X LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. �T� GAS SEISMIC SHUT-OFF VALVE PO.4 DETAILS X THE DRAWINGS SHALL NOT BE SCALED FOR EXACT SHEET TITLE: MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS F__1 WASHER BOX P2.0 PLUMBING WASTE & VENT PLAN X LEGEND, FOR DIMENSIONS. REFER TO MANUFACTURER'S P2.1 PLUMBING SUPPLY PLAN X STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT GREASE INTERCEPTOR GENERAL CONNECTIONS AND INSTALLATION REQUIREMENTS. ® NOTES,AND PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, DRAWING INDEX OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. SHEET NO. P0.0 PLUMBING TABLES PLUMBING NOTES WASHINGTON STATE-COMMERCIAL ENERGY CODE WASTE,VENT, COLDIDE WATER,ANDGHOTTURE WATEROSYSTEMOIN ACO BUILDING CORDANCE 29. IF NEEDED, PROVIDE VACUUM BREAKERS AT ALL HOSE BIBBS. ED TO THE EFFICIENT HEATED WATER SUPPLY P I P I N C CODES.WITH RCON CONNECT EACH FIXTURE, EQUIPMENT, OETC. WITH ALL NS, AND AL 30 DRAINAGE OR RAND ORINS SIMILAR TOT INFREQUENT RAPS TUSE LY OSHALL TBEE PROVIDED \ \ ` ACCESSORIES, VALVES, VACUUM BREAKERS, REGULATORS, UNIONS, WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER /1 /1 /1 8) ETC. AS REQUIRED AND AS RECOMMENDED BY THE MANUFACTURERS. SEALS IN ACCORDANCE WITH 2018 UPC 1007.0. PLUMBING FIXTURE FLOW RATES PER WAC 51-56-0400 REFER TO PLUMBING FIXTURE CONNECTION SCHEDULE ON PLANS. 31. INSULATION MATERIAL SHALL MEET CITY OF BONNEY LAKE QUALITY METHOD #1 - PIPE LENGTH 2. HOT AND COLD: WATER PIPING CONNECTION TO EACH FIXTURE SHALL STANDARDS. (RECOMMENDED METHOD #2 - PIPE VOLUME BE COLD WATER ON THE RIGHT HAND SIDE AND HOT WATER ON THE z z ) FIXTURE TYPE MAXIMUM FLOW RATE NOTES LEFT HAND SIDE. 32. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH 0 O THE 2018 WASHINGTON STATE ENERGY CODE. NOMINAL a MAXIMUM ALLOWABLE MAXIMUM ALLOWABLE 3. HOT WATER: NON-CIRCULATING HOT WATER PIPE SHALL NOT EXCEED PIPE SIZE PIPING LENGTH (4)(7) PIPING LENGTH (5)(6) 10' UNLESS OTHERWISE SHOWN ON DRAWINGS. 33. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH rOi� SHOWERHEADS 1.8 GPM 0 80 PSI 1 (IN) 2018 UPC 701.0 AND 903.0. LAVATORY FAUCETS, RESIDENTIAL 1.2 GPM 60 PSI 2 (FT) PIPE VOLUME (7) (FT) w (FLUID OZ / FEET) 4. VENT STACKS: COORDINATE VENT STACK WITH HVAC EQUIPMENT TO LAVATORY FAUCETS, PUBLIC & NON-RESIDENTIAL 0.5 GPM 0 60 PSI 3 PUBLIC 34. ALL SANITARY SYSTEM MATERIAL SHALL BE LISTED BY AN APPROVED PUBLIC LAVATORY OTHER LAVATORY OTHER MAINTAIN MINIMUM 10' CLEARANCE FROM OUTSIDE AIR INTAKES. LISTING AGENCY. METERING FAUCETS 0.25 GALLONS PER CYCLE 3 FAUCET FIXTURES FIXTURES FAUCET 5. CLEANOUTS: PROVIDE CLEANOUTS PER CURRENT UPC AND AS SINKS 2.2 GPM 0 60 PSI 4 3/8 50 075 267 85. REQUIRED BY LOCAL JURISDICTIONS. CLEANOUTS SHALL BE LOCATED 35. ALL STORAGE WATER HEATING EQUIPMENT SHALL BE PROVIDED WITH 3 . KITCHEN FAUCETS 1.8 GPM 60 PSI 5 IN WALLS/FLOORS WHERE THEY ARE NOT HIGHLY VISIBLE AN APPROVED, LISTED EXPANSION TANK OR OTHER DEVICE DESIGNED a FLOOR o CLEANOUTS IN CARPETED AREAS TO BE FITTED WITH CARPET INSERTS FOR INTERMITTENT OPERATION FOR THERMAL EXPANSION CONTROL PER . PRERINSE SPRAY VALVES 1.6 GPM ®60 PSI 6 1/2 2 43 1.5 1.33 43 2018 UPC 608.3. o GRAVITY TANK-TYPE WATER CLOSETS 1.28 GALLONS/FLUSH LOCATIONS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL. FLUSHOMETER TANK WATER CLOSETS 1.28 GALLONS/FLUSH 5/8 1 32 2 1.00 32 NOTE NOT ALL CLEANOUTS ARE SHOWN ON THE PLUMBING DRAWINGS. 36. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST z 6. SUDS RELIEF: PROVIDE SUDS RELIEF IN ACCORDANCE WITH 2O18 UPC HORIZONTAL DISPLACEMENTS DUE TO SEISMIC MOTION PER 2018 UPC FLUSHOMETER VALVE WATER CLOSETS 1.28 GALLONS/FLUSH 3/4 0.5 21 3 0.67 21 SECTION 711.0, STATE AND LOCAL CODES. 507.2. ELECTROMECHANICAL HYDRAULIC WATER CLOSETS 1.28 GALLONS/FLUSH 37. MATERIAL EXPOSED WITHIN A DUCT OR PLENUM SHALL COMPLY WITH URINALS, WALL MOUNTED 6.125 GALLONS/FLUSH 7/8 0.5 16 4 0.50 16 7. SHUT : PROVIDE TURN BALL VALVE ANGLE STOP SHUT-OFF 2018 IMC 602.2.1. URINALS, OTHER 0.5 GALLONS/FLUSH VALVES SHUT-OFFS AND BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT 1 0.5 13 5 0.40 13 AND COLD WATER SUPPLY TO EACH FIXTURE. EXCEPTION: PROVIDE 38. HVAC EQUIPMENT AND WATER HEATERS SHALL COMPLY WITH 2O18 IMC SCREWDRIVER STOPS AT BATH/SHOWERS. CHAPTER 3. NOTES: 1-1/4 0.5 8 8 0.25 8 1. WHEN A SHOWER IS SERVED BY ONE OR MORE SHOWERHEAD, INCLUDING HANDHELD 8. TUB SPOUTS SHALL BE THREADED (NO PUSH-ON FITTINGS). 39. BOILERS SHALL COMPLY WITH ALL THE REQUIREMENTS OF 2018 IMC SHOWERHEADS, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR SHOWER 1-1/2 0.5 6 11 0.18 6 CHAPTER 10. OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM Q 80 PSI. 9. TRAP ARMS: PROVIDE TRAP ARMS SUCH THAT THE MAXIMUM LENGTH 2 2 OR LARGER 0.5 4 18 0.11 4 WILL NOT EXCEED CODE REQUIREMENTS. 40. PROVIDE EXPANSION TANKS FOR BOILERS PER 2018 IMC SECTION pop Ac WHEN INSTALLED IN COMMON & PUBLIC USE AREAS (OUTSIDE OF DWELLINGS OR SLEEPING O UNITS) IN RESIDENTIAL BUILDINGS, FLOW RATE SHALL NOT EXCEED 0.5 GPM 0 60 PSI 1009.0. O......,!_ NOTES: 10. ADA INSULATION: AT PLUMBING PIPING EXPOSED UNDER LAVATORIES, � 9 3. LAVATORY FAUCETS LOCATED IN RESTROOMS INTENDED FOR USE BY THE GENERAL PUBLIC SHOWER COMBINATIONS SHALL BE PROVIDED WITH INSULATE THE EXPOSED PIPING AND TRAPS WITH PRODUCT 41. SHOWERS AND TUB �.�°F WAS .0 �a 1. CONTRACTOR MAY USE METHOD 1 OR 2 TO DETERMINE MAXIMUM ALLOWABLE PIPING LENGTH FROM / SHALL BE EQUIPPED WITH ASELF-CLOSING METERING VALVE WHEN LEFT UNATTENDED. SOURCE OF HEATED WATER. SPECIFICALLY DESIGNED FOR THIS APPLICATION MEETING ADA MIXING VALVES PER 2018 UPC 408.0. � o EXCEPTION: WHERE DESIGNED AND INSTALLED FOR USE BY PERSONS WITH A DISABILITY. REQUIREMENTS. PROVIDE HANDI-LAV GUARD OR EQUIVALENT. OFFSET EXCEPTION: WHERE INSTALLED IN DAY CARE CENTERS, FOR USE PRIMARILY BY CHILDREN 2. PER 2018 WSEC SECTION C404.3 WATER HEATER, CIRCULATING WATER SYSTEM & HEAT TRACE P-TRAPS TO CLEAR WHEELCHAIR ACCESS. 42. PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH CITY OF 4, 7105 UNDER 6 YEARS OF AGE. TEMPERATURE MAINTENANCE SHALL BE CONSIDERED SOURCE OF HEATED WATER. BONNEY LAKE WATER CONSERVATION STANDARDS. 4 3. THIS TABLE IS BASED ON MINIMUM CODE REQUIREMENT. CONTRACTOR SHALL FOLLOW OWNERSHIP/DEVELOPER 11. WATER HAMMER ARRESTORS: PROVIDE AT THE END OF HOT AND COLD y�. .L ,\ 00�" EXCEPTION: CLINICAL SINKS, LAUNDRY TRAYS, SERVICE SINKS 1ONNA 3ot-3 � 5. REQUIREMENT AND/OR BRAND STANDARD REGARDING MAXIMUM WAITING TIME FOR HOT WATER DELIVERY WATER LINES SERVING TWO OR MORE FIXTURES; SIZE IN ACCORDANCE 43. CONTRACTOR SHALL PROVIDE FIRESTOPPING AT PENETRATIONS AS OpopO g� KITCHEN FAUCETS MAY TEMPORARILY INCREASE FLOW ABOVE THE MAXIMUM FLOW RATE, [OR ALLOWABLE NON-CIRCULATING HOT WATER PIPING LENGTH] AS LONG AS IT IS STRICTER THAN CODE WITH PLUMBING AND DRAINAGE INSTITUTE (PDI) REQUIREMENTS. WATER NECESSARY TO RETAIN THE FIRE RATING OF ALL ASSEMBLIES. ALL 2 BUT NOT ABOVE 2.2 GPM 0 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF MINIMUM HAMMER ARRESTORS ARE REQUIRED FOR QUICK CLOSING VALVES, WORK SHALL BE IN COMPLIANCE WITH CODE REQUIREMENTS FOR THE . CONTACT ENGINEERING AS NECESSARY. 12i 1.8 GPM O 60 PSI. AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION. SUCH AS LAUNDRY WASHERS, FLUSH VALVES (PUBLIC TOILETS), ETC. BUILDING CONSTRUCTION TYPE. 6. 4. PIPE LENGTH METHOD ONLY: WHERE THE PIPING CONTAINS MORE THAN ONE SIZE OF PIPE, THE LARGEST PRERINSE SPRAY VALVES SHALL BE EQUIPPED WITH AN INTEGRAL AUTOMATIC SHUTOFF. SIZE OF PIPE SHALL BE USED FOR DETERMINING THE MAXIMUM ALLOWABLE LENGTH OF PIPING. J J 12. TRAP PRIMERS AS SPECIFIED: PROVIDE TRAP PRIMERS AND PIPING 44. ALL GARAGE DRAINS, TRASH ROOMS DRAINS & GARAGE TRENCH 5. PIPE VOLUME METHOD ONLY: PER WSEC SECTION C404.3.2 THE VOLUME FROM HEATED WATER TO THE FOR FLOOR DRAINS, FLOOR SINKS, AREA DRAINS & HUB DRAINS. DRAINS SHALL BE TAKEN TO SAND/OIL INTERCEPTOR(S) BEFORE TERMINATION OF FIXTURE SUPPLY PIPE SHALL NOT EXCEED 2 FLUID OUNCES FOR PUBLIC LAVATORIES AND ARRANGE PIPING TO ACHIEVE EQUAL FLOW TO EACH DRAIN AND CONNECTING TO THE SANITARY SEWER SYSTEM. 0.5 GALLON (64 FLUID OUNCES) FOR OTHER FIXTURES. FLOOR SINK FOR TRAP PRIMERS SERVING MULTIPLE DRAINS AND FLOOR SINKS. COORDINATE EXACT LOCATIONS WITH ARCHITECT& 45. PLUMBING CONTRACTOR SHALL PROVIDE REDUCED PRESSURE o 0 HANGER SPACING FOR WASTE AND VENT PIPING HANGER SPACING FOR WATER PIPING 6. PIPE VOLUME METHOD ONLY: PER C404.3.z1 WATER VOLUME SHALL BE THE SUM OF INTERNAL VOLUMES OF ELECTRICAL ENGINEER. w �w > BACKFLOW PREVENTERS OR OTHER APPROVED BACKFLOW PREVENTION z z PIPE, VALVES, METERS AND MANIFOLD BETWEEN THE NEAREST SOURCE OF HEATED WATER AND TERMINATION Y O 3 w OF THE FIXTURE SUPPLY PIPE. PROVIDED CALCULATION DOES NOT INCLUDE VALVES, METERS, MANIFOLDS. 13. P-TRAPS SERVING HANDICAPPED COUNTER TOP LAVATORIES SHALL BE DEVICE WHERE REQUIRED BY HEALTH AUTHORITIES, FOOD SERVICE O ¢ a ALL SUSPENDED SANITARY AND VENT PIPE SHALL BE ALL SUSPENDED WATER SUPPLY PIPE SHALL BE DRAWINGS, APPLIANCE MANUFACTURER INSTRUCTIONS AND BY CODE. � 7) SUPPORTED AS FOLLOWS PER 2018 UPC TABLE 313.3: SUPPORTED AS FOLLOWS PER 2018 UPC TABLE 313.3: 7. PER WSEC TABLE C404.3.1 INSULATED. o o a 8. REFER TO MANUFACTURER RECOMMENDATIONS AND PLUMBING FIXTURE SCHEDULE IN COMPLIANCE WITH 2O18 PROVIDE REQUIRED & PROPER BACK FLOW PREVENTERS AS MAX. HORIZ. MAX. VERT. MAX. HORIZONTAL MAX. VERTICAL 14. THROUGHOUT THE PROJECT PROVIDE BALL VALVES. GATE VALVES SPECIFIED FOR THE APPLIANCES INCLUDING, BUT NOT LIMITED TO THE SPACING SPACING SPACING SPACING UPC SECTION A106 AND TABLES 610.3 & A2.1 FOR MINIMUM BRANCH PIPE SIZES. SHALL NOT BE USED. NO EXCEPTIONS. FOLLOWING: ABS 4 FT. 10 FT. COPPER PIPE_< 6 FT. 10 FT. CAST-IRON HUBLESS* EVERY 15 FT. COPPER PIPE >2" 10 FT. 10 FT. 15. HOT WATER RECIRCULATING BALANCING VALVES SHOULD BE BELL & OTHER JOINT COPPER TUBING S1 6 FT. 10 FT. GOSSETT CIRCUIT SETTER (WATTS OR EQUAL) WITH INTEGRAL READOUT PVC TYPE DAY 4 Ff. 10 Fr. COPPER TUBING >2" 10 FT. 10 FT. PORTS, ADJUSTMENT KNOB, DRAIN CONNECTION, AND POSITIVE *CAST-IRON OVER 4' SHALL BE SUPPORTED AT EVERY JOINT CPVC < 1" 3 FT. 10 FT. SHUTOFF. CPVC > 1Y4" 4 FT. 1O FT. 16. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING m CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND (9 OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 2018 WASHINGTON STATE PIPE INSULATION SCHEDULE Z 0 17. REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZEIZE T TO J EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 7 OPTION 1 OPTION 2 m SERVICE VAPOR RETARDER NOTES 1& VALVE TAGS: PROVIDE VALVE TAGS PER SPECIFICATIONS TO IDENTIFY REQUIRED VALVE AND THE AREA IT SERVES. Y MATERIAL THICKNESS MATERIAL THICKNESS 19. OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT. d o DOMESTIC COLD WATER, IRRIGATION WATER, CONDENSATE 20. ALL TEMPERATURE MIXING VALVES SHALL COMPLY WITH ASSE-1070 J z DRAINS, STORM DRAIN (IN CONDITIONED SPACE) MINERAL-FIBER WITH JACKET ALL SIZES: Y2" PVC/NBR ALL SIZES: �" YES 9,10 Q Q E5 SAFETY STANDARDS. m C)Q: DOMESTIC COLD WATER, IRRIGATION WATER, CONDENSATE (R-3) (R-3) 21. PROVIDE PIPE MARKER WITH DIRECTION OF FLOW. LABEL w�¢ z DRAINS, WASTE (OUTSIDE THE CONDITIONED SPACE) MINERAL-FIBER WITH JACKET Yz' PIPE: Y2" PVC/NBR Y2" PIPE: Y2 z' YES 5,6,8 "NON-POTABLE WATER DO NOT DRINK" CLEARLY ON NON-POTABLE ¢3 m O x d 0 ALL OTHER SIZES: 1" ALL OTHER SIZES: �i'i' WATER PIPING. o F-O o F Z_ 00 0 1 1 22. PROVIDE EXPANSION LOOPS EXPANSION JOINTS IN PIPING PER 2018 DOMESTIC HOT WATER AND RECIRCULATED HOT WATER Yz"-1/4" PIPE: 1" Yz"-1/4" PIPE: 1" / o z z z MINERAL-FIBER WITH JACKET PVC/NBR NO 4,7 UPC TABLE 313.3 AND MANUFACTURER INSTALLATION INSTRUCTIONS. z O (NONRESIDETIAL) 1Yz"-4" PIPE:1.5" 1Yz"-4" PIPE:1.5" K rn az.8O -- 23. PROVIDE APPROVED PIPE HANGERS & PIPE SUPPORTS IN Co d EXPOSED SANITARY DRAINS AND DOMESTIC WATER SUPPLIES TRUEBRO LAV-GUARD N/A N/A N/A NO 13 ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND 13.Q z Z AND STOPS FOR ADA FIXTURES. 2018 UPC TABLES 313.3 & 313.6. SUBMIT FOR APPROVAL. ¢ I( NOTES: Z Z 24. DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. ZOO 0 1. SEE BELOW PLUMBING NOTES FOR APPLICABLE CODES. 25. REFRIGERANT PIPING: PROVIDE SIZING & INSTALLATION IN STRICT C7 U' Z 2. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE. CONTRACTOR SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. ADHESIVE TAPE ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. z SHALL NOT BE PERMITTED. Lu 3. NOT USED. 26. CONDENSATE DRAIN: PROVIDE A P-TRAP FOR EACH HVAC UNIT �QQ w CONDENSATE PAN WITH PLUG TEES FOR CLEANING. CONDENSATE 4. PER 2018 WSEC SECTION C404.6 (NON-RESIDENTIAL). DRAINS SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. O Z 5. PIPING FROM WATER HEATER TO THE TERMINATION OF HEATED WATER SUPPLY PIPE SHALL BE INSULATED IN ACCORDANCE WITH TABLE C403.2.9. 6. ON BOTH THE INLET AND OUTLET PIPING OF A STORAGE HOT WATER HEATER, THE FIRST 8 FEET OF PIPING OR PIPING FROM WATER HEATER TO HEAT TRAP SHALL BE INSULATED. 27. PROVIDE VIBRATION, SEISMIC ISOLATIONS & CONTROLS IN ACCORDANCE Z WITH SPEC SECTION 230548. O 7. HEAT TRACED PIPING SHALL BE INSULATED IN THE SAME MANNER AS NON HEAT TRACED PIPING OR PER HEAT TRACE MANUFACTURER SPEC. w 8. TUBULAR PIPING INSULATION SHALL NOT BE REQUIRED FOR THE FOLLOWING: 28. PIPING & EQUIPMENT SUPPORTS/HANGERS & SEISMIC RESTRAINTS TO A. TUBING FROM FROM THE CONNECTION AT THE TERMINATION OF THE FIXTURE PIPING TO A PLUMBING FIXTURE SUPPLY PIPING TO A PLUMBING FIXTURE. BE DESIGNED BY DESIGN BUILT CONTRACTOR. REI JOB #:478-041 B. VALVES, PUMPS, STRAINERS AND THREADED UNIONS IN PIPING THAT IS 1 INCH OR LESS. C. PIPING FROM USER CONTROLLED SHOWER AND BATH MIXING VALVES TO THE WATER OUTLET. D. COLD WATER PIPING OF A DEMAND RETICULATION WATER SYSTEM DATE: 12/29/2023 E. TUBING FROM A HOT DRINKING WATER UNIT TO THE WATER OUTLET. CODES F. PIPING AT LOCATION WHERE A VERTICAL SUPPORT OF PIPING IS INSTALLED. APPLICABLE G. PIPING SURROUNDED BY BUILDING INSULATION WITH R-VALUE OF NOT LESS THAN R-3. I-FT TH F 9. PER 2018 UPC, SECTION 312.6 NO WATER, SOIL OR WASTE PIPE SHALL BE INSTALLED OR PERMITTED OUTSIDE OF THE BUILDING, IN ATTIC OR IN AN EXTERIOR WALL UNLESS ADEQUATE PROVISION IS MADE TO PLUMBING PROTECT SUCH PIPE FROM FREEZING. ALL HOT AND COLD WATER PIPES OUTSIDE THE CONDITIONED SPACE SHALL BE INSULATED TO MINIMUM R-3. THE FOLLOWING PROJECT DESIGN IS BASED ON THE FOLLOWING CODES: 10. HEAT TRACING SHALL BE PROVIDED FOR COLD WATER AND IRRIGATION WATER IN UNCONDITIONED SPACES. REFER TO HEAT TRACING SCHEDULE FOR DETAIL. CONTACT ENGINEERING IF NECESSARY. PER 2018 WSEC NOTES AND SECTION C403.2.4.6 FREEZE PROTECTION SYSTEMS, SUCH AS HEAT TRACING OF OUTDOOR PIPING SHALL INCLUDE AUTOMATIC CONTROLS CONFIGURED TO SHUT OFF THE SYSTEM WHEN OUTDOOR AIR TEMPERATURES -2018 INTERNATIONAL BUILDING CODE (IBC) & WASHINGTON STATE AMENDMENTS TABLES ARE ABOVE 40'E -2018 INTERNATIONAL MECHANICAL CODE (IMC) & WASHINGTON STATE AMENDMENTS 11. PER 2018 WSEC TABLE C4032.9 (FOR NON-RESIDENTIAL) INSULATION FOR HOT WATER AND HOT WATER RETICULATION SHALL HAVE CONDUCTIVITY OF 0.21-0.28 (BTU.IN/H.FT'.'F) ATOPERATING TEMPERATURE. -2018 UNIFORM PLUMBING CODE (UPC) & WASHINGTON STATE AMENDMENTS 12. INSULATION R-VALUE SHALL MEET MINIMUM REQUIREMENT. THICKNESS IS BASED ON GRAINGER SAMPLE DATA FOR K-FLEX(PVC/NBR) AND OWENS CORNING(FIBER GLASS). -2018 WASHINGTON STATE ENERGY CODE WSEC 13. ALL ADA P-TRAPS, HOT WATER SUPPLY TUBING AND SHUT-OFF COCKS SHALL BE PROTECTED WITH APPROVED COVERS TO PREVENT SCALDING. ( ) SHEET NO. -2018 INTERNATIONAL FUEL GAS CODE (IFGC) & WASHINGTON STATE AMENDMENTS 14. REQUIRED BY ENGINEERING BASED ON BEST PRACTICE. 15. INSULATION IS NOT REQUIRED ON PLASTIC PIPING. PO 1 PLUMBING CALCULATIONS PLUMBING SCHEDULES UponorAquaPEXWater Size Table UponorAquaPEHWater Size Tab le UponorAquaPI Water 5¢eTable WATER HEATER ELECTRIC U PC-Flush Valve U PC-Flu h Ta n k UPC-F lush Tank ELECTRICAL 100%Water@60'F 100S6Water@1201F 100%Water@60'F GPH RECOVERY AT STORAGE OPERATING WEIGHT 4.201 PSUl00ft. 4201P51/100ft, 4.201 P5U100ft. EQUIP NO. SERVICE IGOT TR (GALLONS) (LBS) BASIS OF DESIGN NOTES VOLTAGE ELEMENT SIZE # OF ELEMENTS Max Velocity=10ft/ec Max.Velocity=8111 Max%klocfty=10ft./sBc z z O o Pipe WSFU Velocity PIPE WSFU velocity Pipe WSFU Velocity WH-1 TENANT 50 80 850 240V/1P 4.5KW 2 BRADFORD WHITE SLE280T6 1Size Range (ftiteLl Size Range Kim.) lize, Range (ft,.ter_1 a GPM Gpm GPM w 0 U NOTES: 378" 0-0 2.20 0.66 3/13" 0--0 2.40 0.72 "1, 0_0 2,20 0.66 1. INSTALL PER MANUFACTURERS REQUIREMENTS 172" 0-0 2.70 1.49 1/2" 0--0 3.10 1.71 in. 0_0 2.70 1-49 374" 0-0 3.50 3.86 3/4" 1--4 3.90 4.30 3/4" 1_3 3.50 3.86 a 1• 1-1 4.20 7.64 r' 5--11 4.70 8.55 r 4--9 4,20 7.64 EXPANSION TANK SCHEDULE 0 11/4" 2-2 4.90 13.33 11/4' 12--20 5.20 14.42 1114" 10--18 4.90 13.33 EQUIP NO. SERVICE CAPACITY PRE-CHARGE TANK SIZE OPERATING WEIGHT, LBS BASIS OF DESIGN NOTES z GAL. PRESSURE, PSI DIAMETER, IN HEIGHT, IN 11/2" 3-4 5.50 20.84 11/2' 21--35 6.00 22.73 1112" 19--31 5,50 20.84 ET-1 WIT-1 2.0 73 8 14 26 AMTROL ST-SC-DD 1 2' 5-32 6.60 42.80 2" 36--114 7.20 46.78 2' 32--98 6.60 42.88 NOTES: 2VT 33-126 7.60 75.25 21/2' 115--270 8.00 7921 21/2" 99-250 7,60 75.25 1. INSTALL PER MANUFACTURER REQUIREMENTS. 3' 129-395 8.60 121.08 3" 271--443 8.00 112.63 3' 251--484 8.60 121.08 PIPE SIZING FOR COPPER PIPE AT 6.5 PS1/100'WITH HUNTER'S COVE-FLUSH VALVE SIZING HOT WATER C R C U L A O N PUMP SCHEDULE O:g000AOCk 41°COLD WATER 120'HOT WATER 115'RECIRCULATED S� �:'�F WASH•O l� Q WSFU GPM FTIS WSFU GPM FTIS GPM FTIS ELECTRICAL WEIGHT, 1/2" 0.0 2.7 3.8 0.0 3.2 4.4 1.5 2.0 VOLTAGE HP LEE EQUIP NO. SERVICE TYPE FLOW, GPM HEAD, FT PUMP RPM BASIS OF DESIGN NOTES F� _ p 0.0 7.4 4.9 0.0 7.5 5.0 3.0 2.0 HWCP-1 WH-1 INLINE 1 10 VARIABLE 120V/1P .2 22 GRUNDFOS UP15-1865 7105 O 1° 0.0 15.2 5.9 0.0 12.9 5.0 5.1 2.0 00 o°O000/O�wL 1'/° 9.8 26.8 6.8 0.0 19.6 5.0 7.8 2.0 NOTES: OODOO 2gi 1'/:° 32.9 42.8 7.7 10.7 27.7 5.0 11.1 2.0 1. ALL STAINLESS STEEL, MAINTENANCE FREE, SUITABLE FOR POTABLE WATER APPLICATION. 12 2" 1 135.8 77.2 1 8.0 43.1 1 48.2 5.0 1 19.3 2.0 2'/:° 360.0 119.0 8.0 121.9 74.4 5.0 29.7 2.0 3" 713.2 169.9 8.0 280.8 106.2 5.0 42.5 2.0 PIPE MATERIALS SCHEDULE (1) 4" 1782.4 303.2 8.0 853.8 189.5 5.0 75.8 2.0 6" 6381.3 669.1 8.0 2847.0 418.2 5.0 167.3 2.0 0 PIPE TYPE MATERIAL JOINT NOTES o 8" >10,000.0 1168.7 8.0 8014.2 730.4 5.0 292.2 2.0 Z Z Y O U � 10" >10,000.0 1814.3 8.0 >10,000.0 1133.9 5.0 453.6 2.0 WATER DISTRIBUTION PIPING COPPER, TYPE L, OR PEX SOLDERED, PROPRESS, OR EXPANSION FITTINGS w = a 0 U Q 12° >10,000.0 1 2619.3 1 8.0 1 >10,000.0 1 1637.1 1 5.0 1 654.8 1 2.0 UNDERGROUND WASTE AND VENT PIPING ASS OR CO-EXTRUDED PVC, SCH. 40 STANDARD HUBLESS COUPLINGS OR SOLVENT (1)(2) CEMENT WH-1 HOT WATER ABOVE GROUND WASTE AND VENT PIPING ABS OR CO-EXTRUDED PVC, SCH. 40 STANDARD HUBLESS COUPLINGS (1)(3) DEMAND-PEAK HOURLY DEMAND INDIRECT DRAINAGE PIPING COPPER, TYPE M. SOLDERED QUANTITY DEMAND(GPH) TOTAL DEMAND(GPH) NOTES: (1) ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. FIXTURE TYPE PVC PIPING SHALL NOT BE USED FOR RECEPTOR AND TRAP ARM WHERE WASTE TEMPERATURE CAN EXCEED 1107. THIS INCLUDES PIPING AND RECEPTORS FOR 3 COMP SINK, DISHWASHER, m (2) COMMERCIAL LAUNDRY SINK, AND CONDENSATE DRAIN FOR GAS FIRED EQUIPMENT. LAVATORY 2 X 5 = 10 (3) TRAP ARM FOR WASTE RECEPTOR OF SODA DISPENSER SHALL BE PVC. CAST IRON PIPING IS PROHIBITED FOR HIGH ACIDIT DRAINS. (PH < 3). Z SHOWER 2 X 20 = 40BREAKR w 7 OOM SINK 1 OP SINK Y Q o ¢D_ m TOTAL DEMAND[GPH) 70 Q Q N m WH-1 WATER HEATER w Z BASIS OF DESIGN ¢3 0 x O.y <Z 00NU d 3 6i a BRADFORD WHITE SLE28OT6 o Z z z rn>°o O 00 D_ �a3 Z Z_ H OSTORAGE CAPACITY ZOO O0 Z GALLONS FIRST HOUR DELIVERY �� (GALLONS): 114 -- 80%STORAGE.RECOVERY �Q Q FIXTURE UNIT CALCULATION O Z CALCUL -1,ATIONS ARE BASED ON 2018 SPC TABLES A103.1, 1,AND 703.2. 'n NEW PLUMBING FIXTURES U V Z FIXTURE FIXTURE UNITS TOTAL FIXTURE UNITG O TOTAL CW HW WN QUANTITY SERVICE CW ONLY HW ONLYw WN ONLV 0_ LAVATORV(PUBLIC) 1 075 0.75 1 2 2 1.5 1.5 2 WATER-SET(FLUSH VALVE) 5 5 0 4 2 10 10 0 8 REI JOB #:478-041 URINAL 4 4 0 2 2 8 8 0 4 SHOWER 2 1.5 1.5 2 2 4 3 3 4 BREAKROOM SINK 2 1.5 1.5 2 1 2 1.5 1.5 2 DATE: 12/29/2023 DOMESTIC DISHWASHER 1.5 0 1.5 2 1 1.5 0 1.5 2 DRINKING FOUNTAIN 0.75 0.75 0 0 1 0.]5 0.]5 0 0 MOP SINK 3 2,25 2,25 3 1 3 2.25 2.. 3 SHEET TITLE: 2'FLOOR DRAIN o 0 o z 2 10 jo 10 4 PLUMBING 3'FLOOR DRAIN o 0 o s o 0 jo jo o CALCULATIONS 31.25 2] 9.]5 29 &SCHEDULES TOTAL MC2'7771 WNTOTALFIXTUREUNITS: 31.25 29PEAK FLOW: 24 GPM SHEETNO. WATER '�\/REQUIRED SERVICE SIZE TO TENANT SPACE: 1-1YY'CU PO.`' PLUMBING SCHEDULES Z z 0 0 � a w � w a 0 0 z p000ppp�O PLUMBING FIXTURE SCHEDULE 1 5 6 7 8 - PLAN MARK FIXTURE TYPE ROOM LOCATION SIRVICE SIZE INCHESCW HW W V FINISH MANUFACTURER BASIS OF DESIGN NOTES 00 'F0105 113 gE-�. O RESTROOM 104 & X p WATER CLOSET 105 1 - 3 2 WHITE KOHLER K-96057-0 1.28 GALLONS PER FLUSH (3) �/ LE pp00 WC-1 SEAT WHITE BEMIS 1955CT OPEN FRONT 12i FLUSH VALVE CHROME SLOAN 3910168 MANUAL, EXPOSED RESTROOM 104 & J J w URINAL Y2 105 - 2 1Yz WHITE KOHLER K-5452-ET-0 WALL HUNG, REAR OUTLET UR-1 FLUSH VALVE CHROME SLOAN 3912697 MANUAL, EXPOSED LAVATORY RESTROOM 104 & y 2 1Y2 WHITE KOHLER K-2005-0 WALL HUNG w > LAV-1 FAUCET OS CHROME MOEN 843OF05 FLOW RATE 0.5 GPM 3 a N w a SHOWER RESTROOM 104 Y2 Y 2 1Y2 WHITE EVERFAB S6334ATNR LH ADA ALCOVE SHOWER w = a VALVE CHROME MOEN 62320 ROUGH-IN VALVE SH-1 TRIM CHROME MOEN TL181 VALVE TRIM SHOWERHEAD CHROME MOEN 52710EP15 VALVE TRIM SHOWER RESTROOM 105 Yz Y2 2 1Y2 WHITE EVERFAB S6334ATNR RH ADA ALCOVE SHOWER VALVE CHROME MOEN 62320 ROUGH-IN VALVE m SH-2 TRIM CHROME MOEN TL181 VALVE TRIM a Z SHOWERHEAD CHROME MOEN 52710EP15 VALVE TRIM p J_ BREAKROOM SINK BREAKROOM Yz Y2 2 1Y2 STAINLESS DAYTON D12522 SINGLE BOWL DROP-IN Z) 00 S-1 FAUCET CHROME MOEN 8701 SHALL NOT EXCEED 1.8GPM Y f UTILITY SINK WAREHOUSE 3/4 3/4 3 2 WHITE MUSTEE 17W OR EQUIVALENT d N o ¢ w w S-2 FAUCET CHROME MOEN 67315C SHALL NOT EXCEED 1.8GPM Q Q N m C)Q DF-1 DRINKING FOUNTAIN PER DWGS. Y2 - 2 1Y2 ELKAY LZSTLBWSLK ADA DUAL STATION 7 ¢3 0 Foote FD-1 FLOOR DRAIN PER DWGS. - - (2) (2) NICKEL BRONZE SIOUX CHIEF 832 Z Ob O U 3w¢ H ozoz WCO-1 WALL CLEANOUT PER CODE - - - - NICKEL BRONZE TO BE DETERMINED TO BE DETERMINED K rn i O O 00 a FCO-1 FLOOR CLEANOUT PER CODE - - - - NICKEL BRONZE SIOUX CHIEF 834 tr Q z Z NOTES: tALL PROVIDE RED HOT AND BLUE COLD WATER INDICATORS TO ALL FIXTURES. F/�I SIZE PER PLANS. ZZ O FLUSH TRIGGER SHALL BE ON WIDE SIDE OF ROOM. ZOOREFER TO ARCH PLANS FOR MOUNTING HEIGHT. Q O f7j/� 'zCONTRACTOR SHALL CONFIRM MAKE, MODEL AND FINISH OF ALL FIXTURES WITH OWNER, ARCHITECT AND INTERIOR DESIGNER PRIOR TO ORDERING. U)FIXTURE P-TRAPS SHALL BE CHROME-PLATED BRASS. W?? �0 IE 7 PROVIDE DAHL 1/4-TURN BALL VALVE ANGLE STOPS WITH BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT AND COLD WATER SUPPLY TO EACH FIXTURE. fr fr /n w 8 PROVIDE ASSE 1070 LISTED MIXING VALVES AND METERING FAUCETS SET TO 110'F AT ALL PUBLIC-USE LAVATORIES. Q Q w w 9 PROVIDE 1 SUPPLY LINE AND TRANSITION TO 3 4 AT STUB OUT OF WALL. O z O z O r-. � W REI JOB #:478-041 DATE: 12/29/2023 SHEET TITLE: PLUMBING SCHEDULES SHEET NO. P0.3 PLUMBING DETAILS Z Z 00 � a w � � U PIPE SIZE ROD SIZE w UP TO 2" 3/8" DIA. 2 1/2" THRU 3" 1/2" DIA. FIXTURE 4" THRU 5" 5/8" DIA. 6" THRU 7" 3/4" DIA. Q 1 8" THRU 12" 7/8" DIA. J.R. SMITH FIG. 2698 WATER =b SAVER TRAP PRIMER (1%4") ___� n THROUGH-SLAB PENETRATION CLEANOUT PLUG n FINISHED WALL SLEEVE OR WRAP h" PIPING IN WALL -�" n PIPING TO PROTECT FINISHED FLOOR SLOPE ii HANGER RODS CONCRETE FLOOR u AGAINST BREAKAGE FLOOR DRAIN PIPING PER CODE �i _ VIBRATION ISOLATORS OR WALL _ WHERE SPECIFIED - P-TRAP --- CLEVIS HANGER 00 Z� 0 PIPE SHIELD ON INSULATED PIPE SS/ONAL E EO PIPE ODooO 2gi 12� INDIVIDUAL PIPE SUPPORTS PIPE SLAB PENETRATION ��� TRAP PRIMER DETAIL 2 DETAIL o 0 w w > SCALE: NONE SCALE: NONE SCALE: NONE 3 a N w a m INSTALL THERMAL z EXPANSION TANK 7 CONNECT TO SIDE OF m MAIN. DO NOT CONNECT FROM TOP OR BOTTOM NO VALVES OR DEVICES TO BE Y INSTALLED BETWEEN EXPANSION CODE APPROVED VACUUM ET-1 ¢ o TANK AND THE WATER HEATER ¢ RELIEF VALVE REQUIRED PER CODE. d w z 1/3 H FROM TOP AT ALL ELEVATED W.H. Q Q m m w OF THE TANK QW y _ Q m om m 3rnm¢ 2"x16GA. GALV.� HHW�ZF'I®I-�H� 3 p =0o S.M. STRAP UNISTRUT P-1000T F-O N i- CHANNEL, BOLT TO HWCP-1 z O='U o° WALL STRUCTURE HW PROVIDE SHUT o z z NOTE: THE SEISMIC STRAPS WITH (2) 3/8" BOLTS, OFF VALVES. K aoz.O SHALL BE AT POINTS WITHIN MINIMUM. HOT (CONT) HOT (SUP) O THE UPPER 1/3 AND LOWER 00fl Q 1/3 OF THE WATER HEATER. PRESET TEMP Q 3. Z AT THE z MINIMUM LOWER OF 4" SHALL BE o 0 o PROVIDE INTEGRAL 1 (MIXED) COLD z Z PRESSURE TEMP. RELIEF 0 MAINTAINED ABOVE THE VALVE DISCHARGE Z00 HEAT TRAPS HOT (IN) COLD C7(7 Z CONTROLS WITH THE STRAP. WATER INDIRECTLY TO MOP SINK. P1458 BRACKET, (3) 1/2" DRAIN VALVE HEATER z Z Z BOLTS AND NUTS, TYPICAL STAINLESS STEEL DRAIN Wffrfr M wOF 2 PLACES. PAN, 1Yz'� DEEP WITH A H44 Fit w 1" MINIMUM DRAIN THERMOSTATIC MIXING VALVE O Z MAXIMUM ALLOWABLE PIPE LENGTH 1" PIPE INDIRECTLY TO COMPLY WITH ASSE 1070 WASTED TO MOP SINK. BETWEEN FIXTURE AND HOT WATER PER WSEC TABLE C4.4.3.1 o Z WATER HEATER PLATFORM. PLATFORM OR SHELF a REI JO w REFER TO APPLICABLE ARCHITECTURAL DRAWINGS FOR DETAILS. B 1 478-041 MOP SINK DATE: 12/29/2023 SHEET TITLE: DETAILS WATER HEATER SEISMIC STRAPPING 6 WATER HEATER PIPING �� THERMOSTATIC MIXING VALVE 4 SCALE: NONE SCALE: NONE J SCALE: NONE SHEET NO. P0.4 z z 0 0 � a w � w SHEET NOTES: FLAG NOTES 1. NO PROPOSED WORK WILL PENETRATE DEMISING 1. POINT OF CONNECTION TO (E)6"SS. AND/OR RATED WALL ASSEMBLIES. FIRESTOPPING IS ~a REQUIRED IF RATED ASSEMBLY IS PENETRATED. 2. PROVIDE TRAP PRIMER FOR FLOOR DRAIN, SEE o DETAIL 2 ON SHEET PO.4. 2. WASTE & VENT SIZING: WASTE & VENT PIPING SIZED o PER 2018 UPC TABLE 703.2. PIPING 4" AND LARGER Z SHALL BE SLOPED AT 1/8" PER FOOT WITH APPROVAL OF AHJ. PIPING SMALLER THAN 4" SHALL BE SLOPED AT 1/4" PER FOOT: --- PIPE SIZE VERT. I DFU VENT I I � � 1�" 2 DFU 1 DFU 8 DFU I -----T-----T-----T_____� I Y<: I I 2 16 DFU 8 DFU 24 DFU E FCO I; 3" 48 DFU 35 DFU 84 DFU - - - I (E)6"SS - - (E)6"SS Ir 4" 256 DFU 172 DFU 256 DFU 6" 1,380 DFU 576 DFU 1,380 DFU 8" 3,600 DFU 2,112 DFU 3,600 DFU I I �qq❑❑❑ppp L__r________J 3. PROVIDE FLOOR AND WALL CLEANOUTS AS REQUIRED O�p JA�kS BY CODE. SEE ENLARGED PLAN O� F�I (E)6"SS q 7105 nos o &TONAL 13003 12� I I o U � a N w a I I I I I I I I I I I I I I m — IIIIr — — — — — — - - - - 2"SS Z DF-1 1Yz''V � 1Yz"V I w LAV-1 LAV-1 d � �J � z I I S-1 --------• 1 - m I I v 2„V UR- V I �¢ wa 4z 2"v/ UR-1 a 3 n (E)6"SS 3„VT R��Y 3"SS E 6"SS 0 r o o F Z O o U ' 2„V / 3"SS z a 1YzsV 2„V - I 0)O m r z o a U --� I 00a I/y 2"SS\� WC-1 O �' -1 y2"V a FBI Z "v 2„V - Hzz 0 2"v 2"SS �71 � ;2"V s 1,YV2 Z ` FDFD1 r-' I W�� M W S-2 I FD-1 WY W s z v I OZ 3"SS z 3 SS 2 V FCO I aL�i w 4 5 6 8 WASTE VENT REI JOB #:478-041 & PLUMBING WASTE & VENT PLAN ENLARGED PLAN DATE: 12/29/2023 SCALE: 1/16" = V-0" SCALE: 1/4" = 1'-0" 0� SHEET TITLE: V PLUMBING WASTE& VENT PLAN SHEET NO. P2.0 C-1 HT 2023.-IISON ENGINEERING.INC. GLEANER F:\478-OW MENTAL LOCISPCS\WG\P3--BING.DWG 04-19-2013 M59 z z 0 0 � a w � 4 5 6 7 8 SHEET NOTES: w 1. NO PROPOSED WORK WILL PENETRATE DEMISING AND/OR RATED WALL ASSEMBLIES. FIRESTOPPING IS REQUIRED IF RATED ASSEMBLY IS PENETRATED. 2. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND ~a HUB DRAINS. o z 6 FLAG NOTES 0 (E)2"CW (E)2"CW 1. SEE WATER HEATER DETAIL 5 ON SHEET PO.4. ______+ 1Yz"CW `"""""" --- 2. ROUGH IN CW SUPPLY FOR ICEMAKER WITH PLASTIC F7I I RECESS BOX. FINAL CONNECTION BY OTHERS. I "" I 3. ROUGH IN CW SUPPLY FOR ICEMAKER. FINAL Ir I I CONNECTION BY OTHERS. 4. SEE MIXING VALVE DETAIL 4 ON SHEET PO.4. I I 1 5. Y2"HW DOWN TO DOMESTIC DISHWASHER. pOOopppO� L--T------ -J Opp JAc/,N I I 6. POINT OF CONNECTION TO (E)2"CW. 4:-op Wggy.:0200 SEE ENLARGED PLAN (E)3/4CW '~ � o 00 `E,GI1 I05ERF"�'�pp Opo00 I I I 12� J I I o SEE PLUMBING SUPPLY PLAN o j FOR CONTINUATION 3 O a N w a I I I I I I I I I I I I I 1Yz GW 0° IIIr _ I 3/ Ht W Z DF-1 Yz"CW p I I I I �1"Hw d o %"CW w z t = 1"HW 1Y„CW I Qa Lwnm�w I I I I f---------+ 1Y2'CW 3/a"CW I �¢ 3 rn�a 12 5-11 3 1Yz"CW UR-1 1"cw a3 Uz"CW R 1 - - - - �0_ ~0o1- Z O o w a I z Yz'CW 5 'HW I K rn i a 0 Y2"Hw �wH-1 We-1 I WC-1 I"HW I 00a a I/y 1Yi^CW 1 „CW a FBI Z 1'cw � - O — "cw ZOO t7 ET- Y2'CW I Q C7 U' Z CP-11 l _ Yz"HW O F I zZZ �My S-2 I O a s w j O Yz"H W Z A — -Y4"H W Y"CW ~ o Z 3a'CW o w 3�4 H W I a 4 5 6 7 8 SUPPLY REI JOB #:478-041 PLUMBING SUPPLY PLAN ENLARGED PLAN DATE: 12/29/2023 SCALE: 1/16" = 1'-0" SCALE: 1/4" = 1'-0" SHEET TITLE: v PLUMBING SUPPLY PLAN SHEET NO. P2. 1 C-GHT 20]1,ROMISON ENUNEERING INC. GLENN-F:\478-M G-TCS SMARTCAP\ONG\P2--WNMING.OWG 11-23-M2 1- WC-1-WATER CLOSET (LOCATION: UNISEX RESTROOMS 104& 107) HighdiffTM Ultra KOHLER, Top spud flushometer bowl K-96057 Features ' Elongated bowl offers added room and comfort ' 1-1/2" (38 mm)top spud ' 2-1/8" (54 mm)fully glazed trapway ' 10" x 7" (254 mm x 178 mm)water surface ' 1.0 gpf(3.8 Ipf), 1.1 gpf(4.2 Ipf), 1.28 (4.8 Ipf), or 1.6 gpf(6.0 - Ipf)depending on flushometer specified ' Also available with antimicrobial finish K-96057-SS ' 10" or 12" (254 or 305 mm) rough-in ' Supports static load of 2,500 Ibs Material • Vitreous china Technology ' Designed to outperform competitors in bowl cleanliness and plug resistance P �" • Maximum waste removal ADA CSA B651 OBC P'SrePa ' Engineered for toilet seat cover removal APMOR&T • Excellent bowl rinse Codes/Standards ASME Al 12.19.2/CSA B45.1 Engineered to flush effectively in buildings with low supply DOE - Energy Policy Act 1992 pressure and flow EPA WaterSense® ' Maximum drain line carry at all flush volumes per ASME California Energy Commission (CEC) standard ADA Installation ICC/ANSI All 17.1 ' Replaces Highcrest K-4302, Highcliff K-4368 and Highline OBC B651 K-4405. Height and footprint may vary IAPMO Certification KOHLER@ One-Year Limited Warranty See website for detailed warranty information. Available Colors/Finishes Color tiles intended for reference only. Color Code Description 0 White 96 Biscuit 7 Black BlackT_m 1-800-4KOHLER (1-800-456-4537) THE BOLD LOOK Kohler Co. reserves the right to make revisions without notice to product specifications. OE KOHLER, For the most current Specification Sheet, go to www.kohler.com. 12-24-2023 20:35- US/CA/MX HighcliffTM Ultra KOHLER, Top spud flushometer bowl K-96057 F For Back-to-Back Toilet Installations 1 I I I I O I I O I I 28" (711 mm) or I Use a 45' double Do not use a 1-5/8" (41 mm)or 30" (762 mm) �_ wye fitting. double sanitary teed 3-5/8" (92 mm) 26-1/8" (664 mm) Front of Bowl 6-3/8" 1-1/2" Spud (162 mm) 14-5/8" ~(371 mm)— n, 16-1/4" 3-5/8" (92 mm)or (413 mm) 5-5/8" (143 mm) 16-5/8" (422 mm) 15-5/8" (143 mm) 10" (254 mm) o\ 10" 12" (305 mm) of Outlet (254 mm) Technical Information Notes All product dimensions are nominal. Install this product according to the installation Toilet type: Floor-mount instructions. Waste Outlet: Floor For back-to-back toilet installations: Use only a 45o double wye fitting. Bowl shape: Elongated ADA, OBC, CSA B651 compliant when Flush type: Flushometer valve siphon installed to the specific requirements of these Spud size: 1 1/2, Inlet, Top regulations. Trap passageway: 2-1/8" (54 mm) Plumbing codes may require elongated toilets Water surface size: 10"x 7" (254 mm x 178 mm) and elongated, open-front seats in public Rim to water 6" (152 mm) bathrooms. surface: Accessibility standards may require controls to Rough-in: 12" (305 mm) be located on the open side of the toilet. Seat-mounting 5-1/2" (140 mm) holes: Fixture Supply Requirements Min static pressure: 35 psi (241.3 kPa) Max static pressure: 80 psi (551.6 kPa) Min flowing 25 psi (172.4 kPa) pressure: 1-800-4KOHLER (1-800-456-4537) THE BOLD LOOK Kohler Co. reserves the right to make revisions without notice to product specifications. OF KOHLER, For the most current Specification Sheet, go to www.kohler.com. 12-24-2023 20:35- US/CA/MX WC-1-FLUSH VALVE MANUAL FUSHOMETER SLD/�N� (LOCATION: UNISEX RESTROOMS 104& 107) ROYALO ROYALLlll 1 28 CODE NUMBER 3910168 DESCRIPTION 1.28 gpf, Polished Chrome Finish, Fixture Connection Top Spud, Single Flush, Royal® Exposed Manual Water Closet Flushometer. DETAILS • Flush Volume: 1.28 gpf(4.8 Lpf) • Finish: Polished Chrome(CP) • Valve: Diaphragm • Valve Body Material: Semi-red Brass • Fixture Type: Water Closet • Fixture Connection:Top Spud • Rough-In Dimension: 11 1/2" (292mm) COMPLIANCES & CERTIFICATIONS • Spud Coupling: 1 1/2" (38mm) 0 GREEN UPC • Supply Pipe: 1" (25mm) BREEAM' BREEAM CNc� FEATURES • PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed �G EEN �G oEEsT1 O O Bypass • Sweat Solder Adapter with Cover Tube&Cast Wall Flange with Set Screw 0 '6 @ usa w r.5r"sr • Non-Hold-Open Handle, Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation (ADA Compliant, BAA Compliant, BREEAM Materials Credit, • Diaphragm, Handle Packing and Vacuum Breaker to be molded BREEAM Water Credit,Carbon Neutral,cLIPC Green Certified, from PERMEX® Rubber Compound for Chloramine Resistance cUPC Certified, EPD,Green Globes Materials&Resources • ADA Compliant Metal Oscillating Non-Hold-Open Handle Credit,Green Globes Water Credit, HPD, LBC Credit, LEED Materials& Resources EPD Credit, LEED Materials&Resources • 1" I.P.S. Screwdriver Bak Chek® Angle Stop with Free Spinning HPD Credit, LEED V4 Water Efficiency Credit,WaterSense Vandal Resistant Stop Cap Listed, Made in the USA, Satisfies LEED Credits,WELL Building VIDEOS Standard) PVD Special Finishes RECOMMENDED SPECIFICATION Valve Body, Cover,Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass.Valve shall be in compliance with the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2. VALVE OPERATING PRESSURE (FLOWING) 15-80 PSI (103-552 kPa). Specific fixtures may require greater minimum flowing pressure-consult manufacturer requirements. DOWNLOADS • Royal Exposed Installation Instructions • Control Stop Repair and Maintenance Guide • Flush Connections Flanges Repair and Maintenance Guide • Tail Piece Repair and Maintenance Guide • Royal Manual Diaphragm Flushometer Repair and Maintenance Guide • Tools/Accessories • Flushometer Pressure gauges • Additional Downloads Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3910168 • Downloaded 12/29/23 • 07/21/23 •View Latest Version Page 1 of 2 ROYAL@ MANUAL FLUSHOMETER SLOA ROYAL 111-1.28 NOTES All information contained within this document subject to change without notice. Looking for other variations of the ROYAL 111 product?View the general spec sheet with all options. Find a compatible urinal for this flushometer. Find a compatible water closet for this flushometer. WaterSense compliant when used with a WaterSense compliant fixture WARRANTY View Warranty Information ROUGH-IN 21/4"M IN. (57mm) 1" I.P.S. 0 SUPPLY 3 ��� (DN 25mm) /4 O 2'/2" (121mm) (64 mm) 111/2" CENTERLINE (292mm) OF FIXTURE CENTERLINE OF WASTE FIN. FLOOR FIN. WALL Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3910168 • Downloaded 12/29/23 • 07/21/23 •View Latest Version Page 2 of 2 UR-1-URINAL (LOCATION: UNISEX RESTROOMS 104&107) Dexter TM KOHLER, 1-Pint Urinal K-5452-ET Features ' Washout urinal ' 3/4" (19 mm)top spud ' 1 pint or 0.125 gpf(0.47 Ipf) ' Includes inlet and outlet spuds and hangers ' Includes anti-backsplash wall ' 14-3/4" (375 mm)extended rim Material ' Vitreous china Recommended Products/Accessories K-23726 Drain treatment K-23725 Cast iron cleaner K-76317 Urinal flushometer, 0.125 gpf s m P z• IAPMO A&T Codes/Standards ASME Al 12.19.2/CSA B45.1 DOE - Energy Policy Act 1992 EPA WaterSense® California Energy Commission (CEC) ADA ICC/ANSI Al17.1 IAPMO Certification KOHLER@ One-Year Limited Warranty See website for detailed warranty information. Available Colors/Finishes Color tiles intended for reference only. Color Code Description 0 White 96 Biscuit 7 Black BlackT"" 1-800-4KOHLER (1-800-456-4537) THE BOLD LOOK Kohler Co. reserves the right to make revisions without notice to product specifications. OE KOHLER, For the most current Specification Sheet, go to www.kohler.com. 12-24-2023 19:53- US/CA KOHLERDexter TM , 1-Pint Urinal K-5452-ET 13-3/4" (349 mm) - For Retrofit Installation 2-3/8" /(60 mm) (165 (165 mm) /3/4" Spud I I �_1 r�l 11-3/4" +_i- - - (298 mm) 0�1 30" 32-1/2" (762 mm) (832 mm) 20-3/4" To Floor R Floor for (527 mm) for Regular Retrofit Installation 2" N PT Installation Tap\ -�--- -1 24" (610 mm) 0 0 17-1/2" (445 mm) Standard Standard Installation Installation 14-3/4" (375 mm) 17" (432 mm) Max 2" NPT 9-1/2" ADA Installation Tapes (241 mm) Max O ADA Installation 1/4" �J1 Floor (6� 6" (152 mm) Outlet Detail Technical Information Notes All product dimensions are nominal. Install this product according to the installation Spud size: 3/4", Inlet, Top instructions. Max. Water per 0.125 gal (0.5 L) Recommended ADA outlet spud height will Flush: account for normal product variation. For ADA compliance, measurement must be Pressure and Supply Requirements 17" (432 mm) or less from the floor to the top of Fixture pressure min 25 psi (172.4 kPa) the lip. (static): ADA compliant when installed to the specific Fixture pressure 80 psi (551.6 kPa) requirements of these regulations. max(static): 1-800-4KOHLER (1-800-456-4537) THE BOLD LOOK Kohler Co. reserves the right to make revisions without notice to product specifications. OF KOHLER, For the most current Specification Sheet, go to www.kohler.com. 12-24-2023 19:53- US/CA UR-1-FLUSH VALVE (LOCATION: UNISEX RESTROOMS 104& 107) ROYAL® MANUAL FLUSHOMETER SL❑nN. ROYAL 186-0.5 CODE NUMBER 3912697 DESCRIPTION ��- 0.5 f, Polished Chrome Finish, Fixture Connection , Single g To S p P Spud, g Flush, Royal@ Exposed Manual Urinal Flushometer. DETAILS • Flush Volume: 0.5 gpf(1.9 Lpf) • Finish: Polished Chrome(CP) • Valve: Diaphragm • Valve Body Material: Semi-red Brass • Fixture Type: Urinal • Fixture Connection:Top Spud Variation Not Shown: Ground Joint • Rough-In Dimension: 11 1/2" (292mm) • Spud Coupling:3/4" (19mm) • Supply Pipe: 3/4" (19mm) COMPLIANCES & CERTIFICATIONS GREEN FEATURES BREEAM' BREEAM` °Ro cRc �' c o • PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed 19 Ec o Bypass O • Sweat Solder Adapter with Cover Tube&Cast Wall Flange with Set GREEN e GREEN p�oaE= Screw • Non-Hold-Open Handle, Fixed Metering Bypass and No External G�•� Volume Adjustment to Ensure Water Conservation wate,5e usa 4.r� • Diaphragm, Handle Packing and Vacuum Breaker to be molded �•r` from PERMEX8 Rubber Compound for Chloramine Resistance (ADA Compliant, BAA Compliant, BREEAM Materials Credit, • ADA Compliant Metal Oscillating Non-Hold-Open Handle BREEAM Water Credit,Carbon Neutral,cUPC Green Certified, cUPC Certified, EPD,Green Globes Materials&Resources • High mine Resistant PERMEX® Synthetic Rubber Diaphragm Credit,Green Globes Water Credit, HPD, LBC Credit, LEED with Dualual Filtered Fixed bypass Materials&Resources EPD Credit, LEED Materials&Resources • Adjustable Tailpiece HPD Credit, LEED V4 Water Efficiency Credit,WaterSense • 3/4" I.P.S. Screwdriver Bak-ChekO Angle Stop w/Free Spinning Listed, Made in the USA,Satisfies LEED Credits,WELL Building Vandal Resistant Stop Cap Standard) 3/4" I.P.S. Screwdriver Bak-Chek®Angle Stop w/Free Spinning Vandal Resistant Stop Cap RECOMMENDED SPECIFICATION Valve Body,Cover,Tailpiece and Control Stop shall be in VIDEOS conformance with ASTM Alloy Classification for Semi-Red Brass.Valve shall be in compliance with the applicable O PVD Special Finishes sections of ASSE 1037 and ANSI/ASME 112.19.2. VALVE OPERATING PRESSURE (FLOWING) 15-80 PSI (103-552 kPa). Specific fixtures may require greater minimum flowing pressure-consult manufacturer requirements. DOWNLOADS • Royal Exposed Installation Instructions • Control Stop Repair and Maintenance Guide • Flush Connections Flanges Repair and Maintenance Guide • Tail Piece Repair and Maintenance Guide • Royal Manual Diaphragm Flushometer Repair and Maintenance Guide • Flushometer Pressure gauges • Additional Downloads Sloan 10500 Seymour Ave,Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329•sloan.com Code 3912697 • Downloaded 12/29/23 •07/21/23 •View Latest Version Page 1 of 2 ROYAL@ MANUAL FLUSHOMETER SL❑AN, ROYAL 186-0.5 NOTES All information contained within this document subject to change without notice. Looking for other variations of the ROYAL 186 product?View the general spec sheet with all options. Find a compatible urinal for this flushometer. Find a compatible water closet for this flushometer. WaterSense compliant when used with a WaterSense compliant fixture WARRANTY View Warranty Information ROUGH-IN -� - 21/4"MIN. (57mm) =Dr1*0 3/4'I.P.S. O SUPPLY 43/4' (DN 20mm) 111/2, (121mm) (292mm) CENTERLINE OF FIXTURE CENTERLINE OF WASTE FIN. . _ FIN. FLOOR WALL Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3912697 • Downloaded 12/29/23 • 07/21/23 •View Latest Version Page 2 of 2 LAV-1-LAVATORY (LOCATION: UNISEX RESTROOMS 104& 107) KOHLER Kingston TM , Wall-Mount Bathroom Sink K-2005 Features ' Made from premium materials that withstand high-volume usage ' 21-1/4" (540 mm)x 18-1/8" (460 mm) ' Faucet sold separately ' Includes wall hanger Material ' Vitreous china Installation ' Wall-mount ' Drilled for concealed arm carrier installation Recommended Products/Accessories K-8998 P-Trap ADA CSA B651 K-23726 Drain treatment K-23725 Cast iron cleaner Codes/Standards ASME Al 12.19.2/CSA B45.1 ADA ICC/ANSI Al17.1 CSA B651 IAPMO Certification KOHLER@ One-Year Limited Warranty See website for detailed warranty information. Available Colors/Finishes Color tiles intended for reference only. Color Code Description 0 White 96 Biscuit 7 Black BlackT_- 1-800-4KOHLER (1-800-456-4537) THE BOLD LOOK Kohler Co. reserves the right to make revisions without notice to product specifications. OE KOHLER, For the most current Specification Sheet, go to www.kohler.com. 12-25-2023 22:09- US/CA KOHLER Kingston TM , Wall-Mount Bathroom Sink K-2005 2" (51 mm) 4" 1/2" (13 mm) (102 mm) 3-3/4" 18-1/8" (460 mm) 4" (102 mm) (95 mm) 8-1/2" Z _ 8-3/8" 13-3/4" (216 mm) (213 mm) 18-1/4" (349 mm) t- - Leveling Screw Slot 34" I8�" '� \ (464 mm) _ _ _ (864 mm) 203 mni -- O 1-1/4" (32 mm) I( \ Min Locking Device Hole 27" I 111" (279 m ) 17-1/4" (438 mm) O 1-1/4" (32 mm) (686 mm) _ Leveling Screw Hole Min 91, 21-1/4" (540 (229 mm) mm) I Min 8-1/4" (210 mm) Recommended ADA Installation Concealed Arm Hole Locations 5 (127 mm) - - - - � y4-3/8" (111 mm) L 7__ (184 mm) 12" 12-7/8" 29-1/8" (3�5 mm) (327 mm) 33" (740mm) - _ _ _ - -! 31 (845 mm) 3/8" Hot3/8" Cold (787 mm) 4" (1 2 mm) 1-1/4" OD Standard Installation Technical Information Notes All product dimensions are nominal. Install this product according to the installation Bowl configuration: Single instructions. ADA, CSA B651 compliant when installed to Center(s): 4 the specific requirements of these regulations. Bowl area (Only): Length: 16" (406 mm) Width: 10" (254 mm) Water depth: 3-1/8" (79 mm) With overflow: Yes Number of deck 3 holes: Faucet hole spacing: 4" (102 mm) Soap/Lotion hole: 1-1/4" (32 mm) Drain hole: 1-3/4" (44 mm) 1-800-4KOHLER (1-800-456-4537) THE BOLD LOOK Kohler Co. reserves the right to make revisions without notice to product specifications. OF KOHLER, For the most current Specification Sheet, go to www.kohler.com. 12-25-2023 22:09- US/CA LAV-1-FAUCET (LOCATION: UNISEX RESTROOMS 104& 107) MOEN@ Speci f ications COMMERCIAL DESCRIPTION Metal construction with Chrome plated or Classic Brushed Nickel finish • 1/2"IPS connections or flex supply lines(3/8" compression fittings) • Brass adjustable temperature limit stop • Includes metal pop-up type waste assembly or M-BITIONO Single-Handle Lavatory Faucet metal grid strainer where noted LEVER HANDLE FLOW RATE WATERSENSE OPERATION MODEL SIZE (GPM) CONNECTION TYPE DRAIN FINISH CERTIFIED 8400 4" 1.2 IPS Without Chrome x • Pivot action lever style handle in 3"and 4" 8420 4" 1.2 IPS Metal Chrome x FLOW 8420CBN 4" 1.2 IPS Metal CBN x 8422 4" 1.2 Flex Supply Lines Without Chrome x • Water usage is limited to these maximum flow 8422CBN 4" 1.5 Flex Supply Lines Without CBN x rates as indicated by the corresponding product 8422F03 4" 0.35 Flex Supply Lines Without Chrome N/A 84221`05 4" 0.5 Flex Supply Lines Without Chrome N/A markings 8425 4" 1.2 IPS Grid Chrome x CARTRIDGE 8430 1 3" 1.2 IPS Without Chrome x • 1255T""DUrdldstT""cartridge 8430CBN 3" 1.2 IPS Without CBN x g 8430F03 3" 0.35 IPS Without Chrome N/A • Nonmetallic/nonferrous and stainless steel 8430F05 1 3" 0.5 IPS Without Chrome N/A material Lnrome x 8432F05 3" 0.5 IPS Metal Chrome N/A STANDARDS 8434 3" 1.2 IPS Grid Chrome x • Third party certified to WaterSense,®ASME 8437 3" 1.2 Flex Supply Lines Metal Chrome x Al12.18.1/CSA B125.1,and all applicable 8437CBN 3" 1.2 Flex Supply Lines Metal CBN x pp 8439 3" 1.2 Flex Supply Lines Without Chrome x requirements referenced therein 8439CBN 3" 1.5 Flex Supply Lines I Without CBN x • Certified to NSF 61/9&372 8439F05 3" 0.5 Flex Supply Lines I Without Chrome N/A • Products marked with 1.2 gpm are compliant CBN-Classic Brushed Nickel NOTE:This faucet is designed to be with California water efficiency regulations installed thru 3-1"dia.holes,2"on center • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act �a<eTSejy�� • ADA ® for lever handles ® oars EPA c fie WARRANTY 'XI by IAPMO R&T • Warranted for 5 years against material or See table above manufacturer defects 3"Handle Version 4"Handle Version 0 7"(178mm) 7"(178mm) OPEN POSITION OPEN POSITION TOP OF MOUNTING DECK PLATE SURFACE 2" 2" 1 (51mm) (51mm) 1 1-3/4" (45mm) MAX. 4-3/8" 4-3/8" 4" SPACER 011 mm) (111 mm) 001 mm) PROVIDED- DISCARD Lift MOUNT NIG 1 ADAPTER = Rod SURFACE IS 2" 2" MORE THAN (51 mm) (51 mm) 2' 2" 3/4"THICK ESC. ESC. (25mm) (25mm) WIDTH WIDTH 6-1/8"(156mm) ESCUTCHEON WIDTH CRITICAL DIMENSIONS (DO NOT SCALE) FOR MORE INFORMATION CALL: 1-800-BUY-MOEN Rev.4/17 www.moen.com EVERFAB SH 1-SHOWER S6m34A—h R (LOCATION:SHOWER 105) Sub al Sheet Project Name Customer Name Quote Number Date Customization Standard Features Type One-piece roll-in type shower stall.Avai- lable in left or right hand configuration. Color White Exterior Dimensions 63"W x 34"D x 78-1/2"H Materials Gel coat and fiberglass composite Approximate Weight 140 Ibs Certifications and Accessibility Code Compliance PtOENip� (1A� ANSI S�° , N " o Z66 IIII Q�, ® 9eAN oE�EV� Universal CSA 645.5-11/IAPMO ADA ICC A117.1 California HUD/FHA Plumbing Z124-2017 -2017 ANSI Title 24 Code Type A Warranty _ 30 Year Limited Reinforceme Fully reinforced with EverFab's unique composite core material which allows for factory or field installation of ADA compliant grab bars and seat 63 312 1 74 + 34 314 — 60 �1 4 781 781 Reinforcing Bottom Plate Threshold Detail (See Page 3 of Submittal) Due to the nature of the material,all measurements may vary by t 3/8': EverFab 156334A-L/R Submittal Sheet Dimensions needed for site preparation should be measured from the unit. Page 1 EVERFAB S6334A-L/R Submittal Sheet A n! Curtain Rod Detail (See Page 3) 222 1 12 8 B 142 fd14 12 24 253 8 15 Fully Reinforced with EverFab Core Material for factory 18 or field installation 41 of grab bars and 2 seat 34$ 182 Drain Block Out Detail (See Submittal Page 3) Architectural Specifications low A. Shower Stall: 1. Model: No.S6334A-L/R 2. Description:One-piece shower stall with reinforcing bottom plate,slip-resistant floor,and inorganic composite reinforce- ment for placement of grab bars and seat 3. Exterior dimensions:63 inches wide x 34 inches deep x 78-1/2 inches high. 4. TRough-in:+1/8"-0" nominal dimensions 5. Threshold: [Standard] [Low Profile] [No-Recess]Threshold Detail 6. Accessibility Accessories: [AO] [Al] [A2] [A3] [Custom] accessory configuration 7. Optional Accessories: Furnish with [curtain rod], [shower curtain], [recessed soap dish], [composite corner shelf], [shower slide-bar kit], [EverFab Tub-wrap], [shower drain], [18"grab bar], [24"grab bar], [custom grab bar], [folding seat], [T-shaped EverDam]. If applicable, please indicate location of additional accessories on drawing 8. Accessory Style: [AO-No Accessories], [Standard Thru-Bolted], [Flanged], [Elite Series], [Anti-Ligature], [Custom] 9. Accessory Finish: [AO-No Accessories], [Standard Satin Stainless], [Matte Black], [Polished Stainless] [White], [Custom] Due to the nature of the material,all measurements may vary by t 3/8': EverFab I S6334A-L/R Submittal Sheet Dimensions needed for site preparation should be measured from the unit. Page 2 EVERFA B S6334A-L/R Submittal Sheet ADA Accessory Configurations (number following 'A' indicates configuration) 56334AO 56334A1-R 56334A2 56334A3-R No Accessories L-shaped grab bar U-shaped grab bar L-shaped grab bar Seat Seat 18"vertical grab bar S Sealant Reinforcing Finished Sealant 1:2 slope per Bottom Sealant- ADA guidelines Floor Plate Finished Reinforcing g Floor Bottom Finished Floor Reinforcing I Plate I Bottom 1 Plate Floor Subfloor Floor Subfloor 2 1 Subfloor Underlayment Underlayment 4 Standard Low-Profile No-Recess Model number followed with 'LP' Model number followed with 'NR' Additional Details 3 5 O 6"Drain Core O 10"x 2"Block Out 3 3 i _F Subfloor 1 �2 Standard Curtain Rod Location Drain Block-Out Due to the nature of the material,all measurements may vary by t 3/8': EverFab I S6334A-L/R Submittal Sheet Dimensions needed for site preparation should be measured from the unit. Page 3 EVERFA B 56334A-L/R Submittal Sheet Standard Threshold Models Pre-Installed Pre-Installed 18" Pre-Installed Pre-Installed Drain Block Model Number Accessibility Code Compliance L-Shanvrl Grnh Rar Vertic_a1 C=ar U-Shaped Grab Bar Folding ❑ S6334AO No No No No No Adaptable** ❑ S6334A1 Yes No No Yes No ADA,CA Title 24,HUD/FHA ❑ 56334A2 No No Yes No No ADA,CA Title 24,HUD/FHA ❑ 56334A3 Yes Yes No Yes No ADA,ANSI,CA Title 24,HUD/FHA Low Profile Threshold Models Accessibility Code Compliance ❑ S6334AOLP No No No No Yes Adaptable** ❑ S6334A1LP Yes No No Yes Yes ADA,CA Title 24,HUD/FHA ❑ S6334A2LP No No Yes No Yes ADA,CA Title 24,HUD/FHA ❑ S6334A3LP Yes Yes No Yes Yes ADA,ANSI,CA Title 24,HUD/FHA No-Recess Threshold Models Pre-Installed Pre-Installed 1 Pre-installed Drain Block L del Number Accessibility Code Compliance L-Shaped Grab Bar Vertical Grab Bar U Shaped Grab Bar Folding Seat Out Required ❑ S6334AONR No No No No Yes Adaptable** ® S6334A1NR Yes No No Yes Yes ADA,CA Title 24,HUD/FHA Ll 56334A2NR No No Yes No Yes ADA,CA Title 24,HUD/FHA ❑ 56334A3NR Yes Yes No Yes Yes ADA,ANSI,CA Title 24,HUD/FHA **Model is reinforced and capable of meeting accessibility code requirements with proper field-installation of grab bars and seat Seat Placement (indicated by'-L' or'-R'following model number if applicable ® Left Hand ❑ Right Hand *Seat placement is determined as if outside the unit looking in.For clarity,a right hand model is shown in all drawings. ❑ Curtain Rod ❑ Shower Drain ❑ Shower Curtain ❑ 18"grab bar ❑ Recessed Soap Dish ❑ 24"grab bar ❑ Composite Corner Shelf ❑ Custom grab bar, please specify: ❑ Shower Slide-Bar Kit ❑ Folding seat ❑ EverFab Tub-Wrap ❑ T-Shaped EverDam Accessory Stvlem Accessory Finish ❑ Thu-bolted (Standard) ❑ Satin Stainless(Standard) ❑ Flanged ❑ Matte Black ❑ Elite Series ❑ Polished Stainless ❑ Anti-ligature ❑ White ❑ Custom, please specify: ❑ Custom, please specify: of applicable,please select accessory style and finish from options above.If custom,please also indicate desired location(s)on drawing. EverFab I S6334A-L/R Submittal Sheet Page 4 SH-2-SHOWER 6334A L/%] EVERFAB (LOCATION:SHOWER 108) Submittal Sheet Project Name Customer Name Quote Number Date Customization Standard Features Type One-piece roll-in type shower stall.Avai- lable in left or right hand configuration. Color White Exterior Dimensions 63"W x 34"D x 78-1/2"H Materials Gel coat and fiberglass composite Approximate Weight 140 Ibs Certifications and Accessibility Code Compliance PtOENip� (1A� ANSI S�° , N " o Z66 IIII Q�, ® 9eAN oE�EV� Universal CSA 645.5-11/IAPMO ADA ICC A117.1 California HUD/FHA Plumbing Z124-2017 -2017 ANSI Title 24 Code Type A Warranty _ 30 Year Limited Reinforceme Fully reinforced with EverFab's unique composite core material which allows for factory or field installation of ADA compliant grab bars and seat 63 312 1 74 + 34 314 60 �1 4 781 781 Reinforcing Bottom Plate Threshold Detail (See Page 3 of Submittal) Due to the nature of the material,all measurements may vary by t 3/8': EverFab 156334A-L/R Submittal Sheet Dimensions needed for site preparation should be measured from the unit. Page 1 EVERFAB S6334A-L/R Submittal Sheet A n! Curtain Rod Detail (See Page 3) 222 1 12 8 B 142 fd14 12 24 253 8 15 Fully Reinforced with EverFab Core Material for factory 18 or field installation 41 of grab bars and 2 seat 34$ 182 Drain Block Out Detail (See Submittal Page 3) Architectural Specifications low A. Shower Stall: 1. Model: No.S6334A-L/R 2. Description:One-piece shower stall with reinforcing bottom plate,slip-resistant floor,and inorganic composite reinforce- ment for placement of grab bars and seat 3. Exterior dimensions:63 inches wide x 34 inches deep x 78-1/2 inches high. 4. TRough-in:+1/8"-0" nominal dimensions 5. Threshold: [Standard] [Low Profile] [No-Recess]Threshold Detail 6. Accessibility Accessories: [AO] [Al] [A2] [A3] [Custom] accessory configuration 7. Optional Accessories: Furnish with [curtain rod], [shower curtain], [recessed soap dish], [composite corner shelf], [shower slide-bar kit], [EverFab Tub-wrap], [shower drain], [18"grab bar], [24"grab bar], [custom grab bar], [folding seat], [T-shaped EverDam]. If applicable, please indicate location of additional accessories on drawing 8. Accessory Style: [AO-No Accessories], [Standard Thru-Bolted], [Flanged], [Elite Series], [Anti-Ligature], [Custom] 9. Accessory Finish: [AO-No Accessories], [Standard Satin Stainless], [Matte Black], [Polished Stainless] [White], [Custom] Due to the nature of the material,all measurements may vary by t 3/8': EverFab I S6334A-L/R Submittal Sheet Dimensions needed for site preparation should be measured from the unit. Page 2 EVERFA B S6334A-L/R Submittal Sheet ADA Accessory Configurations (number following 'A' indicates configuration) 56334AO 56334A1-R 56334A2 56334A3-R No Accessories L-shaped grab bar U-shaped grab bar L-shaped grab bar Seat Seat 18"vertical grab bar S Sealant Reinforcing Finished Sealant 1:2 slope per Bottom Sealant- ADA guidelines Floor Plate Finished Reinforcing g Floor Bottom Finished Floor Reinforcing I Plate I Bottom 1 Plate Floor Subfloor Floor Subfloor 2 1 Subfloor Underlayment Underlayment 4 Standard Low-Profile No-Recess Model number followed with 'LP' Model number followed with 'NR' Additional Details 3 5 O 6"Drain Core O 10"x 2"Block Out 3 3 i _F Subfloor 1 �2 Standard Curtain Rod Location Drain Block-Out Due to the nature of the material,all measurements may vary by t 3/8': EverFab I S6334A-L/R Submittal Sheet Dimensions needed for site preparation should be measured from the unit. Page 3 EVERFA B 56334A-L/R Submittal Sheet Standard Threshold Models Pre-Installed Pre-Installed 18" Pre-Installed Pre-Installed Drain Block Model Number Accessibility Code Compliance L-Shanvrl Grnh Rar Vertic_a1 C=ar U-Shaped Grab Bar Folding ❑ S6334AO No No No No No Adaptable** ❑ S6334A1 Yes No No Yes No ADA,CA Title 24,HUD/FHA ❑ 56334A2 No No Yes No No ADA,CA Title 24,HUD/FHA ❑ 56334A3 Yes Yes No Yes No ADA,ANSI,CA Title 24,HUD/FHA Low Profile Threshold Models Accessibility Code Compliance ❑ S6334AOLP No No No No Yes Adaptable** ❑ S6334A1LP Yes No No Yes Yes ADA,CA Title 24,HUD/FHA ❑ S6334A2LP No No Yes No Yes ADA,CA Title 24,HUD/FHA ❑ S6334A3LP Yes Yes No Yes Yes ADA,ANSI,CA Title 24,HUD/FHA No-Recess Threshold Models Pre-Installed Pre-Installed 1 Pre-installed Drain Block L del Number Accessibility Code Compliance L-Shaped Grab Bar Vertical Grab Bar U Shaped Grab Bar Folding Seat Out Required ❑ S6334AONR No No No No Yes Adaptable** ® S6334A1NR Yes No No Yes Yes ADA,CA Title 24,HUD/FHA Ll 56334A2NR No No Yes No Yes ADA,CA Title 24,HUD/FHA ❑ 56334A3NR Yes Yes No Yes Yes ADA,ANSI,CA Title 24,HUD/FHA **Model is reinforced and capable of meeting accessibility code requirements with proper field-installation of grab bars and seat Seat Placement (indicated by'-L' or'-R'following model number if applicable ❑ Left Hand I ® Right Hand *Seat placement is determined as if outside the unit looking in.For clarity,a right hand model is shown in all drawings. ❑ Curtain Rod ❑ Shower Drain ❑ Shower Curtain ❑ 18"grab bar ❑ Recessed Soap Dish ❑ 24"grab bar ❑ Composite Corner Shelf ❑ Custom grab bar, please specify: ❑ Shower Slide-Bar Kit ❑ Folding seat ❑ EverFab Tub-Wrap ❑ T-Shaped EverDam Accessory Stvlem Accessory Finish ❑ Thu-bolted (Standard) ❑ Satin Stainless(Standard) ❑ Flanged ❑ Matte Black ❑ Elite Series ❑ Polished Stainless ❑ Anti-ligature ❑ White ❑ Custom, please specify: ❑ Custom, please specify: of applicable,please select accessory style and finish from options above.If custom,please also indicate desired location(s)on drawing. EverFab I S6334A-L/R Submittal Sheet Page 4 SH-1/SH-2-ROUGH IN VALVE (LOCATION:SHOWER 104 8,108, MOEN Specifications Buy it for looks. Buy it for life.' DESCRIPTION • Brass construction O • 1/2"IPS connections • Pressure balancing,four port,cycle valve • Includes pre-installed test plug(cartridge also included inside carton) • Allows valve to be soldered,pressure-tested,and flushed without damaging the cartridge OPERATION • Adjustable temperature limit stop to control maximum hot water temperature • Pressure balancing mechanism maintain selected discharge temperature to 3°F CARTRIDGE POSI-TEMP® VALVE • 1222 cartridge design • Nonmetallic/nonferrous and stainless steel materials Pressure-Balancing Valve • Accommodates back to back installations STANDARDS • Third party certified to meet ASME Al 12.18.1/CSA B125.1,ASSE1016, Model: 2510 (IPS), 2520 (CC), single pack and all applicable requirements referenced therein • Moen's Posi-Temp'and Moentrol°valves with graphite composite 62300 IPS Bulk packed 12 per carton spools combined with Moen's Eco-performance showerheads meet )� p p the performance requirements of pressure and temperature variation of ASSE1016 when tested as low as 1.5 gpm WARRANTY • Lifetime limited warranty against leaks,drips and finish defects to the original consumer purchaser • 5 year warranty if used in commercial installations 2"CC(51 mm) 1 7/8"IPS(48mm) MAX WALL FACE OF STUD 1/2"MIN.CC(13mm) 3/16"(t 4-1/2"(114mm)PLASTER FINISHED WALL LINE 5/8"MIN.IPS(16mm) yp)(5mm) GROUND SIZE AND PLASTER GROUND WALL OPENING 2-1/4"(57mm 3-1/2"(89mm)MIN. )MAX. 2 1/2"MAX. SHOWER (63mm) DIAMETER 11/2 WALL (38mm) OP NING 1 3/8" o 1/2"CC (35mm) SUPPLY 1 3/8" TUB 45"(1143mm)/ (35mm) 2-3/4"(70mm)C.C. 48"(1219mm)-SHOWER 32"(813mm)-TUB OR PLASTIC TUB SHOWER TUB/SHOWER 1 SURROUND FLOORLINE — FLOOR CRITICAL DIMENSIONS (DO NOT SCALE) FOR MORE INFORMATION CALL: 1-800-BUY-MOEN Rev.5/15 9g www.moen.com SH-1/SH-2-VALVE TRIM (LOCATION:SHOWER 104& 108) MOEN Specifications f ications Buy it for Looks. Buy it for Life! There is more than 1 version of this model. Page down to identify the version you have. DESCRIPTION • Metal construction with various finishes identified by suffix Ice • Includes non-metalic showerhead,arm,flange and non-metalic diverter tub spout OPERATION • Handle operates counterclockwise through a 270'arc with off at 6 o'clock and maximum hot at the 9 o'clock position.Shut off in clockwise direction • Adjustable temperature limit stop to control maximum hot water _ temperature • Pressure balancing mechanism maintains selected discharge temperature to 3° FLOW CHATEAU' POST-TEMP • Showerhead is limited to 2.5 gpm(9.5 L/min)at 80 psi $I le-Handle Tub/Shower Trim Kit • EP suffix models are limited to 1.75 gpm(6.6 L/min)at 80 psi n g • NH suffix models contain no showerhead CARTRIDGE Models: TL181 series-valve trim only • 1222 cartridge design • Accommodates back to back installations (bulk Packed 12 per carton • Nonmetallic/nonferrous and stainless steel material TL182 series-shower trim only STANDARDS (Bulk Packed 12 per carton) • Third party certified to meet ASME Al 12.18.1/CSA 13125.1 and all TL183 series-tub/shower trim applicable requirements referenced therein • EP suffix models are third party certified to WaterSense° (Bulk Packed 12 per carton) • ADA ® for lever handle Valves: 62300 series WARRANTY 2500 series • Lifetime limited warranty against leaks,drips and finish defects to the original consumer purchaser • 5 year warranty if used in commercial installations �,z�eTSe�� m Pfs EPA G 2"CC(51mm) c"mn"a er 1 7/8"IPS(48mm) iAPMD R&T MAXWALL �FACE OFSTUD EP Suffix 1/2"MIN.CC(13mm) FINISHED WALL LINE 5/8"MIN.IPS(16mm) Models Only 2-5/8" 7-1/2" (67mm) ~(190mm) 3/16"(typ)(5mm) PLASTER GROUND 6ES(.DIAM.) IT 2 1/2"MAX.(63mm) 1 1/2"MAX. ESC DIAM. 38mm) 6'-6" + 4-1/2"(114mm) (1981mm) WALLOPENING -- NOMINAL DIRECTION f OF HANDLE DIAMETER ROTATION WALL 1-3/8"(35mm) OPENING 1 3/8" 35mm) SHOWER 3-1/2"(89mm)MN. 45"(1143mm)/ 2-1/4"(57mm)MIN. PLASTIC TUB/SHOWER 48"(1219m m) SURROUND (133mm) 32"(813mm) L{ TUB/SHOWER AND TUB ONLY TUB RIM FLOOR LINE FLOOR LINE THICK WALL APPLICATION THIN WALL APPLICATION CRITICAL DIMENSIONS (DO NOT SCALE) FOR MORE INFORMATION CALL: 1-800-BUY-MOEN TL183sp:Rev.5/13 - www.moen.com MOEN eci S� f ications Buy it for Looks. Buy it for Life! DESCRIPTION • Metal construction with various finishes identified by suffix • Includes non-metalic showerhead,arm,flange and non-metalic diverter tub spout OPERATION • Handle operates counterclockwise through a 270'arc with off at 6 o'clock and maximum hot at the 9 o'clock position.Shut off in clockwise direction • Adjustable temperature limit stop to control maximum hot water _ temperature • Pressure balancing mechanism maintains selected discharge temperature to 3° FLOW CHATEAU' POST-TEMP • Showerhead is limited to 2.5 gpm(9.5 L/min)at 80 psi $I le-Handle Tub/Shower Trim Kit • EP suffix models are limited to 1.75 gpm(6.6 L/min)at 80 psi n g • NH suffix models contain no showerhead CARTRIDGE Models: TL181 series-valve trim only • 1222 cartridge design • Accommodates back to back installations (Bulk Packed 12 per carton) • Nonmetallic/nonferrous and stainless steel material TL182 series-shower trim only STANDARDS (Bulk Packed 12 per carton) • Third party certified to meet ASME Al 12.18.1/CSA 13125.1 and all TL183 series-tub/shower trim applicable requirements referenced therein • EP suffix models are third party certified to WaterSense° (Bulk Packed 12 per carton) • ADA ® for lever handle Valves: 62300 series WARRANTY 2500 series • Lifetime limited warranty against leaks,drips and finish defects to the original consumer purchaser • 5 year warranty if used in commercial installations �l�erSe,� m s EPAOt 2"CC(51 mm) ed�� IAPMO R&T 1 7/8"IPS(48mm) EP Suffix MAX WALL FACE OF STUD 1/2"MIN.CC(13mm) Models Only FINISHED WALL LINE 5/8"MIN.IPS(16mm) 2-5/8" 7-1/2" (67mm) ~(190mm) 3/16"(typ)(Smm) PLASTER GROUND 7" I� 2 1/2"MAX.(63mm) 1 1 1/2"MAX. C.DIAM. ESC.DIAM. 38mm) 4-1/2"(114mm) (1981mm) WALL OPENING -- NOMINAL _ DIRECTION 1 OF HANDLE DIAMETER ROTATION WALL 1-3/8"(35mm) OPENING 1 3/8" 35mm) SHOWER 3-1/2"(89mm)MAX. 45"(1143mm)/ 2-1/4"(57mm)MIN. PLASTIC TUB/SHOWER 48"(1219m m) SURROUND 5-1/4"� (133mm) 32"(813mm) L j TUB/SHOWER AND TUB ONLY TUB RIM FLOOR LINE FLOOR LINE CRITICAL DIMENSIONS (DO NOT SCALE) FOR MORE INFORMATION CALL: 1-800-BUY-MOEN TL183sp:Rev.5/13 - www.moen.com SH-1/SH-2-HAND SHOWER (LOCATION:SHOWER 104& 108) MHOEN" Specifications There is more than 1 version of this model. Page down to identify the version you have. DESCRIPTION • Chrome plated or Classic Brushed Nickel (CBN)finish • Single function handheld shower with non-positive shut off • Contains:hand-held shower,30"slide bar,drop ell, 72" metal hose and mounting hardware • SLIDE BAR IS NOT TO BE USED AS A GRAB BAR • Supplied with vandal resistant screws • Quick cleaning rubber nozzles FLOW 0 • 2.5 gpm (9.5 L/min) at 80 psi Models: 52710series, 52710EP15series • EP suffix models are limited to 1.5 gpm (5.7L/min) at 80 psi Hand-Held Shower STANDARDS System • Third party certified to WaterSense® (Ep Models Only) ASME Al 12.18.1/CSA B125.1,ASSE 1014 and all applicable requirements a�erSP, referenced therein �" @ � • ADA® is EPA G��¢Yp • Backflow prevention compliance through ASME Al 12.18.3 0 "`"0PV WARRANTY EP Models Only • Limited lifetime warranty against leaks,drips and finish defects to the original homeowner • 10 year limited warranty when used in a multifamily installation • 5 year limited warranty when used in a commercial installation Visit wwww.moen.com/support for complete details and limitations 8-1/8"SPRAY WAND FINISHED HEIGHT WALL LINE 3-5/16"SPRAY 2"Dia. DROP ELL---- HEAD DIAMETER 1/2-14 NPT \ 1/2-14 � X NPSLTHR THREAD 6'-6"(1981 mm) 28-1/2" NOMIMAL NOMINAL (723mm) 1 TUB RIM--- FLOOR LINE CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.10121 www.moen.com MOENO Specifications DESCRIPTION • Chrome plated or Classic Brushed Nickel (CBN)finish • Single function handheld shower with non-positive shut off • Contains: hand-held shower,30"slide bar,drop ell, 69" metal hose and mounting hardware • SLIDE BAR IS NOT TO BE USED AS A GRAB BAR • Supplied with vandal resistant screws • Quick cleaning rubber nozzles FLOW 0 52710(2.5gpm/9.5 Ipm)-Chrome finish 52710CBN (2.5gpm/9.5 Ipm) -CBN finish 52710EP15(1.5gpm/5.7 Ipm)-Chrome finish;WaterSense®certified Hand-Held Shower 52710EP15CBN (1.5gpm/5.7 Ipm)-CBN finish;WaterSense®certified System STANDARDS • Third party certified to WaterSense° (only applies to 1.5 gpm),ASME �atieTses� Al 12.18.1/CSA B125.1,ASSE 1014 and all applicable requirements P ¢m referenced therein EPAG' • ADA® EP Models Only • Backflow prevention compliance through ASME Al 12.18.3 WARRANTY • Warranted for 5 years against material or manufacturing defects 8-1/8"SPRAY WAND FINISHED HEIGHT WALL LINE 3-5/16"SPRAY HEAD 2"DiDROP ELL---_ DIAMETER i 1/2-14 NPT 1/2-14 NPSL THREAD 6'-6"(1981 mm) 28-1/2" NOMIMAL NOMINAL (723mm) 1 TUB RIM-_ FLOOR LINE CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.11/14 www.moen.com DAYTO N. Dayton® Stainless Steel 25" x 22" x 6-9/16" Single Bowl Drop-in SPECIFICATIONS S-1-BREAKROOM SINK Sink (LOCATION: BREAKROOM 106) Model(s D12522 PRODUCT SPECIFICATIONS Dayton®Stainless Steel 25"x 22"x 6-9/16"Single Bowl Drop-in Sink. Sink is manufactured from 22 gauge 300 series Stainless Steel with a Satin finish, Center drain placement, and Bottom only pads. Installation Type: Drop-in Material: 300 series Stainless Steel Finish: Satin Gauge: 22 Sound Deadening: Bottom only pads Number of Bowls: 1 Sink Dimensions: 25"x 22"x 6-9/16" Bowl 1 Dimensions: 21"x 15-3/4"x 6-3/8" Drain Size: 3-1/2" (89mm) Drain Location: Center Minimum Cabinet Size: 30" Mounting Hardware: Part#64090012 included for countertops up to 3/4" (19mm)thick A Century of Tradition and Quality. Template Included: No For more than 100 years,Elkay has been making innovative products and providing exceptional customer care.We take pride in offering Cutout Template#: 1000001188 plumbing products that make life easier,inspire change and leave the Template is available for download at elkay.com. CAD software will be world a better place. required to open the template. Product Compliance: ADA& ICC Al 17.1 Cutout Dimensions for Drop-in Installation: ASME Al 12.19.3/CSA B45.4 24-3/8"x 21-3/8"(619mm x 543mm)with 1-1/2" (38mm)corner radius Sinks are listed by IAPMO®as meeting the applicable requirements N of the Uniform Plumbing Code°, International Plumbing Code°,and Hole Drilling Configurations: National Plumbing Code of Canada. ® Complies with ADA&ICC Al 17.1 accessibility requirements when installed according to the requirements outlined in these standards. 1-1/2"(38mm)Diameter Faucet Holes on 4"(102mm)Centers Clean and Care Manual (PDF) O 0 0 o Installation Instructions(PDF)- 1000005236 Warranty(PDF) Similar models are available with: ADA Depths, MR 0 0 0 0 0 master pack quantities ® 0 0 0 © 0 © 10 0 0 0 22" (559mm) -+- 15-3/4" (400mm) 4"R (102mm) 1 21" (533mm) 25" (635mm) PART: QTY: 73-1/4"R 6-9/16" PROJECT: 83mm) (167mm) CONTACT: DATE: NOTES: APPROVAL: In keeping with our policy of continuing product improvement,Elkay reserves the right to change product specifications without notice.Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 11162023 1-800-476-4106 1 CustCare(cDElkay.com ©2023 Pagel D12522 Patent zurn-elkay.com/patents D12522_spec.pdf DAYTO N. Dayton® Stainless Steel 25" x 22" x 6-9/16" Single Bowl Drop-in SPECIFICATIONS Sink Model(s) D12522 Installation Profile: Silicone Caulk (not tumished) Sink FU-Channel Countertop ScrewLnj Optional Accessories GBG2115SS Dayton Stainless Steel 17-1/2"x 12-1/4"x 1" Bottom Grid Spec Sheet(PDF) CB1516 Elkay Hardwood 15"x 16-3/4"x 3/4" Cutting Board � Spec Sheet(PDF) Dayton 3-1/2" Stainless Steel Drain with Removable Basket Strainer and Rubber Stopper D1125 �''�'• Spec Sheet(PDF) In keeping with our policy of continuing product improvement,Elkay reserves the right to change product specifications without notice.Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 11162023 1-800-476-4106 1 CustCare(cDElkay.com ©2023 Page 2 D12522 Patent zurn-elkay.com/patents D12522_spec.pdf S-1-FAUCET (LOCATION: BREAKROOM 106) MOEN Specifications COMMERCIAL DESCRIPTION • Solid brass construction • Chrome finish • 3/8"compression x 22"stainless steel supply lines • Optional deck plate OPERATION • Lever style handle • Pull-on/Push-off • Temperature controlled by 110'arc of handle travel FLOW • Aerator is limited to 2.2 gpm max(8.3 L/min) CARTRIDGE • Ceramic 40mm cartridge design with an adjustable temperature limit stop Nonmetallic/nonferrous and ceramic material Single-Handle Kitchen Faucet STANDARDS • Third party certified to ASME Al 12.18.1/CSA 13125.1,and all applicable requirements referenced therein Model: 8701 • Contains no more than 0.25%weighted average lead content • Certified to ANSI/NSF 6 • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act • ADA ® for lever handle WARRANTY NOTE:DESIGNED TO BE INSTALLED • Warranted for 5 years against materials or manufacturing defects THROUGH 1 HOLE 1-3/8" MIN. DIA. HOT COLD SS- �SS 12" (305mm) ON 25' (152mm) I 5" (126mm) 10-1/2" (267mm) 2-11/64" (55mm) 1-1/2"MAX. (38mm) 2" (50mm) 9 (229mm) CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.5/12 = www.moen.com ICE-1-ICE MAKER BOX (LOCATION: BREAKROOM 106) ICE MAKER OUTLET BOX 14 696 SERIES OXBOX M ITEM#SUBMITTED JOB NAME SPECIFICATION Sioux Chief 696 series OXBo)0 outlet box shall be used where necessary in LOCATION plumbing systems. Unit shall allow for mounting with supply lines from top ENGINEER or bottom, on-stud or between-studs. Unit shall include plated, 1/4-turn valve with 1/4" compression outlet. Valve outlets shall be provided with tamper- CONTRACTOR resistant test caps. Metal support bracket can be installed into tracks of box. Po# TAG Designed in accordance with IAPMO PS 54-2021a. MATERIALS Valve body: Forged brass' Valve shank: Brass'or CPVC with 304SS grip ring, brass nut,silicone seal Box/Frame:ABS A Arrester body:304SS barrel with brass'body 696-G1010XF Arrester piston: Polypropylene with EPDM o-rings Bracket: Galvanized steel CERTIFICATIONS/APPROVALS NSF-372 compliant', IAPMO listed box and valves, Arresters meet ASSE 1010, Valves meet ASME A112.18.1 — -- VALVE/ARRESTER WORKING LIMITS Max Working Temperature: 2000 F 696-G1000CR Max Testing/Working Pressure: 150 PSIG DIMENSIONS A: Frame width 5-7/8" B: Frame height 7-1/4" C: Box width 4" D: Box height 5-1/2" E: Box depth 3-1/2" F: Supply inlet 1/2" Nom. G: Supply outlet 1/4" Compression —E— —C— Bracket length 17" A i T I D B G o 0 F Create Item Number 696-ABC e.g.696-G1010XF: Ice maker outlet box with frame;valve with arrester,F1807 connection ARRESTERS A SUPPLY CONNECTION B FRAME OPTION C ❑ G1000 =No arresters ❑ C =CPVC(male) ❑ F =Standard Pack:Outlet box,frame,bracket,and debris cover ❑ G1010 =With arresters ❑ M =MIP/FSWT ❑ R =Rough-in Pack: Outlet box,bracket,and debris cover ❑ P =MSWT/Press/Push ❑ V =F3347 PEX Accessories-Available Separately: pma ❑ W =F1960 PEX 696-1F:Single-box frame 696-EX:Frame extension ❑ X =F1807 PEX �Pc 1 C69300 material is DZR and SCC resistant,compliant with NSF-61&372,and compliant with California No Lead Plumbing Law H55E soxo Sk=ChM Sioux Chief Manufacturing Company I P:1.800.821.3944 1 F:1.800.758.5950 1 www.siouxchief.com ELM S -UTILITY SINK MUSTEE (LOCATION:WAREHOUSE 120) 17F and 17W UTILATUBO ® Preferred by the"Pros" Laundry/Utility U S Premier Design features: • High strength,one piece molded construction ® Produced with Mustee's proprietary DURASTONE@—combination of fiberglass and crushed stone blended with special resins for extra strength and durability • Built-in scrub board,angled for easy access ■ 19 Gallon capacity,extra deep 13"tub with smooth surface • Leakproof,integrally molded-in drain with stopper ■ Connects to standard 11/2"P or S trap • Accommodates dual-handle faucet with 4"center ■ Large,self-draining back shelf with retainer curb that prohibits water run-off except into tub. • Floor model includes heavy gauge steel legs with adjustable levelers ■ Wall model includes wall mounting bracket,side supports and mounting hardware for securing tub to concrete or stud wall ■ Mold and mildew-resistant components ■ Easy to assemble and install ■ Color-fast,marbleized white finish Code Accepted: UTILATUBO and UTILATWINO Laundry/Utility Tubs meet or exceed performance requirements as listed: International Association of Plumbing and Mechanical Officials(IAPMO)@ Listed c o ■ Warnock Hersey@(Canada) Listed—CSA test standards: Laundry Tray-#B45.0 and#B45.5; Drain-#B125 ■" In[ertek ■ American National Standards Institute(ANSI)—Specification Z 124-2011 ANS Specifications Colors & Models: Model Mounting H x W x D UPC White 17F Floor 34"x 23"x 23-1/2" 6 71031 00023 1 White 17W Wall 34"x 23"x 23-1/2" 6 71031 00024 8 77 General:Furnish and install as shown on plans,UTILATUBO Laundry/ Utility Tub model—(17F,17W),as manufactured by E.L.Mustee ts" &Sons,Inc.Tub shall be one-piece molded construction using e DURASTONEO,a blend of natural crushed stone and polyester resins molded with matched metal molds under extreme heat and pressure. 3 FILLER ' Tub to include built-in scrub board,integrally molded drain assembly 34" O APPROX. APPROX. PANELS for connection to standard 1-1/2"P or S-trap,stopper and wall mounting hardware or heavy gauge steel legs with built-in levelers. 19 gallon capacity tub,13"deep.Shall meet ANSI Z 124-2011.Color: L 4 11 White.Weight:17F 31 lbs.;17W 30 lbs. E�M o L info@ usteelcom. Web:5 www.mest tustee com Proudly made Br n the USA Phone:216.267.3100 • Fax:216.267.9997 MUSTEE E-mail: Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. ECM MUSTEE Laundry/Utility Laundry/Utility Tub Accessories Preferred by the"Pros" • Faucet xx s Faucet Block For use with overhead water supply d R HandiFlo" Fitting"' H�hL fCV'w�IErr OESCMAafiE Fn"r�. Faucet Model No. UPC 93.600 6 71031 00232 7 A14 Chrome finish, 4"center set brass faucet. 7"swing spout with aerator, level handles, replaceable seats and stems.Areator or hose end. Faucet Block Model No. UPC 20.600 6 71031 00031 6 Used when water supply lines are above the tub. Mounts to tub shelf when using a clamp-on faucet. HandiFloTM Fitting Model No. UPC 94.700 6 71031 00287 7 Dispenses water from washing machine discharge hose into laundry tub. Eliminates draping washer r-. machine hose over back/side wall of laundry tub and conceals discharge hose. Mounts to back or side wall of laundry tub, includes mounting hardware. ElM® MUSTEE E-mail:info@ usteelcom. • Web:ewww mustee com - Proudly made in the USA ok Park,OH 44142 - Phone:216.267.3100 • Fax:216.267.9997 Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. S-2-FAUCET ® LOCATION:WAREHOUSE 120) MOEN S p e ci f i c a t i o n s There is more than one version of this model. Page down to identify the version you have. DESCRIPTION • Metal construction with various finishes identified by suffix • Pullout spray with 59"braided hose • Flexible supplies with 3/8"compression fittings OPERATION • Lever style handle • Temperature controlled by 100'arc of handle travel • Spout rotation is 120* • Operates with less than 5lbs.of force r • Operates in stream or spray mode in the pullout or retracted position FLOW Flow is limited to 1.5 gpm(5.7 L/min)at 60 psi Integral CARTRIDGE g 1255—Duralast—cartridge Single Control Kitchen Faucet STANDARDS • Third party certified to IAPMO Green,ASME All 12.18.1/CSA B-125.1 and all applicable requirements referenced therein including NSF 61/9&372 Models: 67315 series • Meets CalGreen and Georgia SB370 requirements • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act NOTE:DESIGNED TO INSTALL • The backflow protection system in the device consists of two independently THROUGH 1 OR 3 HOLES 1-1/2"(38mm) DIA. operating check valves,a primary and a secondary which prevent backflow GREEN ADA ® for lever handle D PO WARRANTY Lifetime limited warranty against leaks,drips and finish defects to the original homeowner 10 year limited warranty when used in a multifamily installation • 5 year limited warranty when used in a commercial installation Visit www.moen.com/support for complete details and limitations 9-5/8, (241 mm) 10-5/8" (270mm) 7-5/8" (194mm) 5-9/16" (141mm) l 1 I 2-1/2" (63.5mm) Max.Deck Thickness 28-1/2" (724mm) CRITICAL DIMENSIONS (DO NOT SCALE) FOR MORE INFORMATION CALL: 1-800-BUY-MOEN Rev.7/20 www.moen.com �`a MOENO S p e ci f► cations DESCRIPTION • Metal construction with various finishes identified by suffix • Pullout spray with 59"braided hose • Flexible supplies with 3/8"compression fittings OPERATION • Lever style handle • Temperature controlled by 100'arc of handle travel • Spout rotation is 120* • Operates with less than 5lbs.of force r • Operates in stream or spray mode in the pullout or retracted position FLOW Flow is limited to 1.5 gpm(5.7 L/min)at 60 psi Integral CARTRIDGE g 1255—Duralast—cartridge Single Control Kitchen Faucet STANDARDS • Third party certified to IAPMO Green,ASME Al 12.18.1/CSA B-125.1 and all applicable requirements referenced therein including NSF 61/9&372 Models: 67315 series • Meets CalGreen and Georgia SB370 requirements • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act NOTE:DESIGNED TO INSTALL • The backflow protection system in the device consists of two independently THROUGH 1 OR 3 HOLES 1-1/2"(38mm) DIA. operating check valves,a primary and a secondary which prevent backflow GREEN ADA ® for lever handle D PO WARRANTY • Lifetime limited warranty against leaks,drips and finish defects to the original consumer purchaser • 5 year warranty if used in commercial installations 9-5/8, (241 mm) 10-5/8" (270mm) 7-5/8" (194mm) 5-9/16" (141mm) l 1 I 2-1/2" (63.5mm) Max.Deck Thickness 28-1/2" (724mm) CRITICAL DIMENSIONS (DO NOT SCALE) FOR MORE INFORMATION CALL: 1-800-BUY-MOEN Rev.6/17 www.moen.com a MOENO s p e ci f n► catios DESCRIPTION • Metal construction with chrome plated or brushed chrome finish • Quick connect installation • Pullout spray with 59"braided hose • 1/2"IPS connections will accept standard ball nose / connection for 3/8"tubing OPERATION • Lever style handle • Temperature controlled by 180'arc of handle travel • Spout rotation is 120' • Operates with less than 5lbs.of force , ADA • Operates in stream or spray mode in the pullout or retracted position FLOW Single Control Kitchen Faucet Models: • Aerator is limited to 2.2 gpm (8.3 L/min)at 60 psi CARTRIDGE • 1225 cartridge design Models:67315C, 67315SL • Engineered polymers,nonferrous and stainless steel materials STANDARDS • Third party certified to CSA B-125,ASME Al 12.18.1 M,NSF 61 NOTE:DESIGNED TO INSTALL Section 9,California Proposition 65,ANSI A117.1 and all applicable requirements referenced therein THROUGH 1 OR 3 HOLES 1-1/4" (32mm)MIN.DIA. • The backflow protection system in this device consists of two independently operating check valves,a primary and a secondary which prevent backflow. WARRANTY • Lifetime limited warranty against leaks,drips and finish defects to the original consumer purchaser • 5 year warranty if used in commercial installations 9-5/8" (241 mm) 10-5/8" (270mm) 7-5/8" (194mm) 5-9/16" (141mm) l 1 r 2" (51 mm) Max.Deck Thickness CI CRITICAL DIMENSIONS (DO NOT SCALE) Rev.8/13 FOR MORE INFORMATION CALL: 1-800-BUY-MOEN www.moen.com a ELK.4Y Elkay eZH2O Bottle Filling Station & Versatile Bi-Level ADA Cooler SPECIFICATIONS DF-1-DRINKING FOUNTAIN Filtered Refrigerated Light Gray Model LZSTL8WSLK (LOCATION: BREAKROOM 106) PRODUCT SPECIFICATIONS Elkay ezH2O@ Bottle Filling Station &Versatile Bi-Level ADA Cooler Filtered Refrigerated Light Gray. Chilling Capacity of 8.0 GPH (gallons per hour)of 501 F drinking water, based on 801 F inlet water and 901 F ambient, per ASHRAE 18 testing. Features shall include Antimicrobial*, Filtered, Green Ticker TM, Hands Free, Laminar Flow, Real Drain, Visual Filter Monitor. Furnished with Flexi-Guard®Safety Bubbler. Electronic Bottle Filler Sensor with Electronic Front and Side Bubbler Pushbar activation. Product shall be Wall Mount(On Wall),for Indoor - applications, serving 2 station(s). Unit shall be certified to UL 399 and y CAN/CSA C22.2 No. 120. Special Features: Antimicrobial, Filtered, Green Ticker TM, Hands Free, Laminar Flow, Real Drain,Visual Filter Monitor Finish: Light Gray Granite Power: 115V/60Hz Bubbler Style: Flexi-Guard®Safety Bubbler Activation by: Electronic Bottle Filler Sensor with Included with Product: Water Cooler(LZSTL8WSLC), Electronic Front and Side Bubbler Bottle Filler(LZWSR), Pushbar Filter Mounting Type: Wall Mount(On Wall) V Ships in multiple boxes. Chilling Capacity*: 8.0 GPH A Century of Tradition and Quality. Full Load Amps 6 For more than 100 years,Elkay has been making innovative Rated Watts: 370 products and providing exceptional customer care.We take pride in USA offering plumbing products that make life easier,inspire change and 0 Dimensions(L x W x H): 36-3/4"x 19"x 39-1/16" leave the world a better place. Approx.Shipping Weight: 104 lbs. PRODUCT COMPLIANCE Installation Location: I Indoor ADA& ICC A117.1 No. of Stations Served: 1 2 *Based on 80' F inlet water&90' F ambient air temp for 50' F chilled ASME Al 12.19.3/CSA B45.4 drinking water. CAN/CSA C22.2 No. 120 Special Note: Installs with stainless steel back panel (1000004920); GreenSpec° accessory to enhance design &ease of installation. NSF/ANSI 42, 53, 61 (Q:51), &372 (lead free) UL 399 • Visual Filter Monitor: LED Filter Status Indicator for when filter change is necessary. �AP^^o GreenSpec® • Filter is certified to NSF 42 and 53 for lead, cyst, particulate, �� U$ RaT L I ST E D chlorine,taste and odor reduction. 3,000 gal. capacity. • Green Ticker: Informs user of number of 20 oz. plastic water ® Complies with ADA&ICC Al 17.1 accessibility requirements when installed according to the requirements outlined in these standards.Installation may bottles saved from waste. require additional components and/or construction features to be fully • Laminar flow provides clean fill with minimal splash. compliant.Consult the local Authority Having Jurisdiction if necessary. Installation Instructions(PDF)- 1000002243 • Key plastic components are manufactured with silver ion antimicrobial agent helping to provide clean, stain-and odor-free 5 Year Limited Warranty on the refrigeration system of the unit. surfaces. Electrical components and water system are warranted for 12 months • Real Drain System eliminates standing water. from date of installation. Warranty pertains to drinking water applications only. Non-drinking water applications are not covered under warranty. Warranty(PDF) PART: QTY: PROJECT: CONTACT: DATE: NOTES: APPROVAL: In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 10272023 1-800-260-6640 1 SVtechservicetcDElkay.com ©2023 Pagel LZSTL8WSLK Patent zurn-elkay.com/patents LZSTL8WSLK_spec.pdf ELK.4Y Elkay eZH2O Bottle Filling Station & Versatile Bi-Level ADA Cooler Filtered Refrigerated Light Gray SPECIFICATIONS Model LZSTL8WSLK *Antimicrobial claims are in refence to components manufactured antimicrobial agents, helping to provide clean, stain-and odor-free surfaces. COOLING SYSTEM • Compressor: Hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication. • Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated. • Cooling Unit: Combination tube-tank type. Continuous copper tubing with is fully insulated with EPS foam that meets UL requirements for self-extinguishing material. • Refrigerant Control: Refrigerant R-134a is controlled by accurately calibrated capillary tube. • Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. Optional Accessories Elkay WaterSentry Replacement Filter(Bottle Fillers& Liv Pro) 51300C Spec Sheet(PDF) Elkay Cane Apron for EZ Gray LKAPREZL Spec Sheet(PDF) emo In-wall Carrier for Bi-level On-wall Bottle Fillers Coolers& Fountains M LP200 Spec Sheet(PDF) 98551C WaterSentry Filter Mounting Cover(Gray Granite) � Spec Sheet(PDF) In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 10272023 1-800-260-6640 1 SVtechserviceCaDElkay.com ©2023 Page 2 LZSTL8WSLK Patent zurn-elkay.com/patents LZSTL8WSLK_spec.pdf ELK.4Y Elkay eZH2O Bottle Filling Station & Versatile Bi-Level ADA Cooler Filtered Refrigerated Light Gray SPECIFICATIONS Model LZSTL8WSLK IMPORTANT! INSTALLER PLEASE NOTE: OPERATION OF QUICK CONNECT FITTINGS This water cooler has been designed and built to provide water to the user which Simply push in Tube is secured Push in collet to has not been altered by materials in the cooler waterways.The grounding of electrical tube to attach T e is sn release tube equipment such as telephone,computer,etc.to water lines is a common procedure. p The grounding may be In the building but may also occur away from the building.This grounding can cause electrical feedback into a water cooler creating an electrolysis 4 which creates a metallic taste or causes an increase in the metal content of the water. A B C This condition is avoidable by installing the cooler using the proper materials as shown Pushing tube in before below. NOTICE pulling it out helps to This water cooler must be connected to the water supply using a dielectric coupling.The release tube cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completely Isolate the cooler from the building plumbing syysstem. Bottle filler unit on bracket attached to wall by 6 holes(as shown).Water and electrical will connect through pre-punched hole in basin. These products are designed to operate on 20 psi to 105 psi supply line pressure.Simultaneous operation of both bubblers on a bi-level unit may not be possible depending on water supply pressure.If simultaneous operation is desired,please ensure a minimum of 65 psi supply. WaterSentry®Plus Filter System ROUGH-IN FOR LEFT-HAND HIGH SIDE MODELS 17-718" 0 7/16" 19" 7„(454mm)7 UR18 ND (483mm) 78mm) 178mm HOLES(6) 3-9/16" (1 " (90mm) 18-3/8" (467mm) ACTIVATION SENSOR 0 9/32" 6-3/8" 6-3/8" 6-318" (7mm) (162mm) (162mm) (162mm) (162mm HANGER 18-7/8" 2, (12 HOLES) 15" ( BRACKET (479mm) (51mm) (381mm) 2-718" i (73mm) 2" O - 2 kl � (51mm) ((38-3/8"E t{ (51mm) — bRFMM C51-9116" FILTER :f— (22mm) r i HEIGHT (� (1310mm) L -1 36-13/16" r B PREFERRED E (936mm) 8-1116" i i „ LOCATION RIM (205mm) F L _ J Tip HEIGHT q 34-5/16" _ I 38-112" FILTER y (872mm) - I ??� (979mm) ((32-7/8" i 24-1/2" D 8-13116 bR F C (622mm) PREFERRED - (732mm) HEI HT LOCATION 31-5116" 22-15/16" 2 21-7/8" (796mm) (583mm) 51mm F (556mm) RIM 17-7/16" 98 m ( ) 19,, HEIGHT 27„ 1-7/16" 19-7/16" (443mm) 13-15/16" 53/4� (483mm) (686mm) 12-1/2"(37�nm) (494mm) (354mm) (146mm) ADA (318mm)(77mm) 7" 7" REQUIREMENT (178m6) (178mm) FINISHED FLOOR LEGEND: REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER A=Recommended Water Supply location.Shut-off Valve not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. B=Recommended Waste Outlet location.To accommodate 1-1/2"nominal drain.Drain stub 2"(51 mm)out from wall. C=1-1/2"Trap(not furnished). D=Electrical Supply(3)Wire Recessed Box Duplex Outlet. E=Insure proper ven{ilatlon by maintaining 6"(152mm)minimum clearance from cabinet louvers to wall. F=7/16"(11 min)Bolt Holes for fastening to wall. Note:New Installations Must Use Ground Fault Circuit Interrupter(GFCI).It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 10272023 1-800-260-6640 1 SVtechserviceCcDElkay.com ©2023 Page 3 LZSTL8WSLK Patent zurn-elkaV.com/patents LZSTL8WSLK_spec.pdf ELKAY Elkay eZH2O Bottle Filling Station & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLK IMPORTANT! INSTALLER PLEASE NOTE: OPERATION OF QUICK CONNECT FITTINGS This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.The grounding of electrical Simply push in Tube is secured Push in collet to equipment such as telephone,computer,etc.to water lines is a common procedure. tube to attach in position release The grounding may be In the building but may also occur away from the budding.This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. A B C This condition is avoidable by installing the cooler using the proper materials as shown Pushing tube in before below. NOTICE pulling it out helps to This water cooler must be connected to the water supply using a dielectric coupling.The release tube cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completely Isolate the cooler from the building plumbing system. Bottle filler unit on bracket attached to wall by 6 holes(as shown).Water and electrical will connect through pre-punched hole in basin. Those products are designed to operate on 20 psi to 105 psi supply line pressure.Simultaneous operation of both bubblers on a bi-level unit may not be possible depending on water supply pressure.If simultaneous operation is desired,please ensure a minimum of 65 psi supply. WaterSentry'Plus Filter System ROUGH-IN FOR RIGHT-HAND HIGH SIDE MODELS (0 7116" 17-718" 19.. 061I" 7" (454mm)- (483mm) ROUNDHOLES( (178mm) (178mm) 3-9/16" (90mm) " ACTIVATION (467mm18-3/8) SENSOR 6-3/8" 6-318"11 0 91m 179mm 062mm) (162mm) 6-3/8" 6-3/8" 12(HOL1 S) BRACKET (479mm) 15„ (162mm) (162mm) (381mm) (51" 2-7/8" (73mm) i 2" O (51rn L A /fp PREFERRED 38-3/8" LOCATION (975mm1 E ORIFICE (51-9/mm) E i � ( ) — HEIGHT ^�_y 517/8 36-13/16" - (2718' '� (936mm) 8-1/16" L 38-1/2" — RIM (205mm) r r — (979mm) FILTER I J _ HEIGHT 28-13/16" 32-7/8" FILTER i (732mm) i 34-5116' (835mm� 1 2„ F (872mm) RIFIC I I 21-7/8" F _ J (51mm) 241/2„ HEIGHT (556mm - 5-3/4" (622mm) 31-5/16" 19 (146mm) (796mm) 13-15116"(483mm) PREFERRED 7" 7 22-15/16" RIM1-7/16" (354mm) 3-718"L�-D LOCATION (178mm) (178mm) (583mm) HEIGHT 27" (37mm) 17-7/16" (98mm) (686mm) (443mm) ADA 12-1/2" 3. 19-7/16' REQUIREMENT (318mm)(77mm) FINISHED FLOOR (494 11 mm) REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A=Recommended Water Supply location.Shut-off Valve not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. B=Recommended Waste Outlet location.To accommodate 1-1/2"nominal drain.Drain stub 2"(51mm)out from wall. C=1-1/2"Trap(not furnished). D=Electrical Supply(3)Wire Recessed Box Duplex Outlet. E=Insure proper venttilation by maintaining 6"(152mm)minimum clearance from cabinet louvers to wall. F=7/16"(11 mm)Bolt Holes for fastening to wall. Note:New Installations Must Use Ground Fault Circuit Interrupter(GFCI). It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 10272023 1-800-260-6640 1 SVtechservice�Elkay.com ©2023 Page 4 LZSTL8WSLK Patent zurn-elkay.com/patents LZSTL8WSLK_spec.pdf FD-1-FLOOR DRAIN (LOCATION: RESTROOMS&SHOWER ROOMS) ADJUSTABLE FLOOR CLEANOUT 11834 SERIES FinishLine'" ITEM#SUBMITTED JOB NAME SPECIFICATION Sioux Chief 834 series FinishLine adjustable on-grade cleanout shall be LOCATION used where necessary in drainage systems. Cleanout shall allow adjustment ENGINEER before and AFTER the concrete pour. Scoriated cleanout cover shall meet CONTRACTOR applicable load requirements for intended use. Cleanout shall include a slotted, Po# TAG polypropylene or brass cleanout plug, situated in base adapter. Designed in accordance with ASME A112.36.2M MATERIALS Ring/cover: Nickel-bronze,304 stainless steel Coring plug: High-impact polymer Coring sleeve:ABS Head adapter:ABS Base adapter:ABS, PVC Cleanout plug: Polypropylene, brass LOAD RATING 4,000 lbs.(medium-duty) DIMENSIONS A: Connection 3" Sch. 40 Hub',4" Sch. 40 Hub B: Ring/cover diameter Rnd: 6-1/2" Sqr:6-5/8" 834-4PN R C: Base adapter height 4-1/2" D: Pre-pour height 5-3/8"-6-5/8" E: After-pour height Rnd:0"-1-1/4" Sqr: 5/16"-1-1/4" F: Cleanout plug 3-1/2" slotted 1 Fits inside most 4"Sch.40 pipe B T E i I D C F A Create Item Number 834-A B C D e.g.834-4PNRV: FinishLine cleanout with 4" PVC Sch. 40 hub and round, nickel-bronze,vandal-resistant ring/cover CONNECTION SIZE A RING/COVER C OPTIONS D Available separately: ❑ 3 =3" Sch.40 Hub ❑ NR =Round nickel-bronze ❑ V =Vandal-resistant cover screws Leveling shim kit:(832-4) Extension adapter:(832-EX4) ❑ 4 =4" Sch.40 Hub ❑ NQ =Square nickel-bronze ❑ S =Stamping:specify letters Flexible locating bristle kit:(832-w) ❑SR =Round stainless steel ❑ C =Carpet marker FinishLine plug wrench:(832-P) CONNECTION TYPE B ❑ SQ =Square stainless steel ❑ B =Brass cleanout plug2 ❑A =ABS Base adapter ❑ Z =Complies with Buy American Act3 ❑ P =PVC Base adapter 2 In lieu of polypro(standard) 3 Available for items with round nickel-bronze covers only Sk=ChM Sioux Chief Manufacturing Company I P:1.800.821.3944 1 F: 1.800.758.5950 1 www.siouxchief.com WH-2-WATER HEATER (LOCATION:WAREHOUSE 120) BRADFORD MITE° W A T E R H E A T E R S Large Volume Light Service Commercial Upright Electric Water Heater Bradford White Light Service Upright Electric Models Feature: ■ Fully Automatic Thermostat Controls—Fast acting surface-mount thermostats with a high limit energy cut-off(manual reset)for safety. ■ Direct Heat Transfer With Immersed Elements—Transfers heat directly and efficiently to the water. Screw-in style. INCOLOY°elements standard for all models. ■ Vitraglas®Lining with Microban®—An exclusively engineered enamel formula that provides superior tank protection from the corrosive effects of water; and with Microban°antimicrobial product protection to help prevent the growth of bacteria, mold and mildew on the surface of the tank lining. ■ Factory-Installed Hydrojet®Total Performance System—Sediment build- up reducing device that also increases first hour rating of hot water while minimizing temperature build-up in tank. ■ Insulation System-2" (51 mm) Non-CFC foam insulation covers the sides and top of the tank, reducing heat loss.This results in less energy consumption, improved efficiencies, and jacket rigidity. ■ Water Connections-3/4" (19mm) NPT factory-installed true dielectric fittings extend water heater life and simplify water line connections. 1" (25mm) NPT for SLE2120T. ■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation. ■ Protective Anode Rod—Provides added protection against corrosion for long-term,trouble-free service. ■ Steel Tank—Heavy gauge steel automatically formed, rolled, and welded. ■ Wired at 277V,Single Phase, 12.2kW(6100W/6100W Simultaneous operation) only. ■ T&P Relief Valve Installed On Top. ■ NSF 5 kits available. Photo is of SLE265T6 FEATURING: MICROBmh 6-Year Limited Tank Warranties/1-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA and Puerto Rico.Some states do not allow limitations on warranties.See complete UL S A® copy of the warranty included with the heater. LISTED Microban®antimicrobial product protection helps prevent the growth of bacteria, mold and mildew that may affect the product.The built-in antimicrobial properties do not protect users or others from disease-causing organisms.Microban®is a registered trademark of Microban Products Company. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S.PATENTS:5,682,666;7,634,976;5,660,165;5,954,492;6,056,542;6,935,280;5,372,185;5,485,879;5,574,822;7,971,560;7,992,526;6,684,821;7,334,419; 7,866,168;7 270 087;7,007,748;5,596,952;6,142,216;7,699,026;5,341,770;7,337,517;7,665,211;7,665,210;7,063,132;7,063,133;7,559,293;7,900,589;5,943,984;8,082,888;5,988,117;7,621,238;7,650,859;5,761,379; 7:409:925;5:277:171;8,146,772;7,458,341;2,262,174.OTHER U.S.AND FOREIGN PATENT APPLICATIONS PENDING.CURRENT CANADIAN PATENTS:2,314,845;2,504,824;2,108,186;2,143,031;2,409,271;2,548,958;2,112,515; 2,476,685;2,239,007;2,092,105;2,107,012.Vitraglas®and Hydrojet®are registered trademarks of Bradford White®Corporation.Microban®is a registered trademark of Microban Products Company. 1415-H-0323 Commercial Electric Water Heater Large Volume (Light Service) Upright Models Meet or exceed ASHRAE 90.1(latest edition).C.E.C.Listed Model Nominal Recovery at A B C D E G Approx. Number Gal. 100*F Rise* Floor to Jacket Floor to C/L of Floor to Water Shipping Capacity Top of Dia. Water Water T&P Conn. Weight Heater Conn. Conn. Conn. NPT U.S. Imp. U.S. Imp. Gal. Gal. GPH GPH in. in. in. in. in. in. lbs. SLE265T6 65 54 50 42 60 22 61 8 611/16 3/4 156 SLE280T6 1 80 67 1 50 42 1 60 1 24 1 61 1 8 1 616/16 1 3/4 1183 16 b bV/16 Model Nominal Recovery at A B C D E G Approx. Number Liter 56°C Rise* Floor to Jacket Floor to C/L of Floor to Water Shipping Capacity Top of Dia. Water Water T&P Conn. Weight Heater Conn. Conn. Conn. NPT Liters/ Hour mm. mm. mm. mm. mm. mm. kg. SLE265T6 246 189 1524 559 1549 203 1564 19 71 SLE280T6 303 189 1524 610 1549 203 1564 19 83 SLE2120T6 450 189 1600 711 1646 203 1640 25 138 Based on 6100/6100,Simultaneous operation.Elements are tripled rated for 277 Volt 6100W/6100W,240 Volt 4500W/4500W,208 Volt 3500W/3500W. NSF 5 Kits available when ordering.All models meet DOE's standby loss requirements. Recovery♦ Recovery 1 13 GPH Temperature Rise°F LPH Temperature Rise°C Wattage 60 80 90 100 120 Wattage 34 45 50 56 67 U D 12,200W 82 62 56 50 42 12,200W 310 234 212 190158 (203mm) O A GPH based on Simultaneous operation. ® 1 I t G G C E A General: All models are compliant with EPAct.All heaters are wired inter-locking(Simultaneous,Single Phase)277V with two 6100W elements.All water and electrical connections are 3/4" NPT(19mm)except for SLE2120T(1" NPT(25mm)).All models certified at 300 PSI test pressure(2068 kPa) and 150 PSI working pressure(1034 kPa.) Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. —BRADFORD WHITE IS— AM° RICAN Sales:800-523-2931 ■Fax 215-641-1612 STRONG. 2417 Technical Support:800-334-3393■Email techserv@bradfordwhite.com Products made by Bradford White are manufactured in the United States using the finest raw materials and components from around the world. Built to be the Best 1415-H-0323 02023,Bradford White Corporation,USA.All rights reserved. Printed in U.S.A. CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 - BUILDING PERMIT Wr 17216 51ST AVE NE STE 110 Permit#:5753 Parcel#:31052100400100 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Tenant 48 TI Valuation:60170.00 APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT Wolfe Plumbing Inc WOLFE PLUMBING INC INDUSTRIAL PA 8201 164TH AVE NE STE 110 832 80th St Sw 832 80th St SW REDMOND,WA 98052 Everett,Wa,98203 Everett,WA 98203 3607948621 360-794-8621 UC:601753508 EXP:11/30/2024 LIC:WOLFEPI0330 EXP:01/26/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL PLUMBING CODE YEAR: 2018 STORIES: 0 CONST.TYPE: IDB DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: _ PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 1/09/2024 �11�•. 01/09/2024 A plicant Signature Date Building Official Date - CONDITIONS ■ Approved job copy shall be onsite for inspections.Adhere to approved plans. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. M PERMIT FEES Date Description Fee Amount 01/09/2024 Plumbing Commercial Plan Review $698.84 01/09/2024 Credit Card Service $20.97 01/09/2024 Processing/Technology $25.00 01/09/2024 Dishwasher $15.00 01/09/2024 Drinking Fountain $15.00 01/09/2024 Floor Drain $60.00 01/09/2024 Icemaker/Refrigerator $15.00 01/09/2024 Ktchen Sink&Disposal $15.00 01/09/2024 Lavatory $30.00 01/09/2024 Plumbing Base $25.00 01/09/2024 Plumbing Msc. $15.00 01/09/2024 Shower(only) $30.00 01/09/2024 Sink(bar,service,etc.) $15.00 01/09/2024 Toi I ets $30.00 01/09/2024 Urinals $30.00 01/09/2024 Water Heater(Tank) $25.00 Total Due: $1,064.81 Total Payment: $1,064.81 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail cn`y 7L82NH21HVNN(1`J:l0ViN00 .7N1`9NRl33NIJN3 000000 °po o awr :03AOJddV 3 -- EtEE'b9E(90Z)3NOHd Op d��0 uj 9E086 VM'000MNNA'I C I]�.7t o w p o�� ZOE EMS 3AV H10b l Ob6 l N O V 1 yl o� � � O Z_ a°oU::�� o! awr 03NO3H0 f �: p Q = :03NOIS30 m ~ W W W ; VM 'NOIDNIIHtl N011dIJOS30 31VC 'ON pop o00 8 UNIG-line - )WVd iviuisnaNl 1HOdHIV NOl!DNllHV op oo ,30 :NMVJO dVOiHVWS Si, 1N`dN31 �,.�3ro,� �� lu Lu °z s Jolsin3J Z 0 Cl) w Z p O 3 to r L,-1 2 n W x > �. z0. r Yw° kza zzz a m z I w � zx > o m O wz 0 5 aa> m, 0w- Z > ws JOUQQmQN3 o N Qw� z z o=aZ� ° O F— �o auz>x¢x}} m 3 d \ \w < w w x om ¢3 �';� Wn 2: a �wo0o o o ;w J N Wo ww oa , Zw OZOW O 4Q N w o 2 Ox WN Z $i 0�3xawx0 �. t^ am O OJ�N�r�� n a 9 o- N wv° �} z° m o �o�x} > oN�ww G �tl xm xzwwx w 0 (.) w wozoJ w� oin ooxxoxozz� x rn 0-worn xlnwln ¢Fx G1nz¢¢a Jmuza 011. r° wm 3a 'C"C000000zwz� >z°ww0 w�www(Lowwox°am1^a od'wxoaJWO x3dwQ? win > �, W, ri z °xz ° W 20�V NJ VxZ W I'� >5i�mom �o»?�°owwm�?cxoO3vw°�r�o¢maomwa0zi&Z2aaaaaa �Zog� Li oo0aaaaaaaaaaaxxxaxrnvlrnrnrnrnrncncncn00 V)�r-�� 002.1>1 333 06 wzwaoN ..----_._..:..__.___., Q owv2 L) Oz V> °orn3 m 3 y > z on w °Fvir J a oox Ou5W lrn3owa a opwww �xoax nn�oq xox o ° U 0oaaaa aan.aaawxx xrn tnwnvlrnrntncnvlWOVO)cntnr- k »»5333 3 J Zzso ` o F W O o X z £ZOZ/6Z/Zl x x x x x x x a w~w 13S lIWJ3d Z x o a00xw II I x U x O 6 M W U m W ZZZ x W W OO Z<z O Od Y ¢ r 3 JO r �x+1W x = dN Q dO�oZN 1r OF W o a ¢aQ$m Z m o:, mx > zw�< 3z 3 W aww o z o«Jw �Z ? wz JJa z o �o�ox9 of a 2ro Nz0" <°wom O / o Zw �m Q VW Jx Ozw Jx� mVmN Za OC>= Z r, xmJF_Uw o0z wQNO� Z WWN WONWWWfnQ3F-m QZ~O�QQQ6QaVwa f!I 2} w°U�xx }}� wwOZO Z O W aJOQ�Zo>N3WOCW �a33333Fm� =3��Zx0ac3°2Z �z� ozQ°c�iz a o LL wwwwXaaaamaa ¢ow0000200000wo0�'m wz3a'ba° zawowoo~7 �a�xaA z ~ o x wwWww UOOOOUODU'252222222x222Z ZZZZ YYJJd 3of5f mmzzzO =mwFrs O Z apNU. Q CD 6 W V 1 I 1 Cl) o�amUx 1 ) a w a co N V/ 5 0 ter v°i x Cl) U m V) I- wwwww omono o� xxxxxxx x�x xUOW2ZYYJJwz��zzf abz°zo ozw€oo Vr/ o (� W izF° a �x� F w a¢w O O LOL Z} Z F x W N U w (d F x ZZ r 1,w-- Z Z LLJ U N 3 N U O ¢x W v°i w l,J LI,J,J cFi mwa<az 0zzz zz ��Ox �- W wF ZZryZ NU�NZ° f- z m m m J m OUw2 Zx- O Ka yJjZZ =Q N U 0WO�Za N W U 7 7 W J J J W J J x O� ma7 Z r w WUZ J d W W O d 4 w Qww Na. � oww z2 z Od Wzu,l �++�� ° w0 �aF�w� a xxxxOf x z a �y o �- xz ti x zwm< ° zN On on W x oa zUx o�x oo O as zoo Q0.xFaz rn W OO wwrV-FAQ UwdU ZWO�Z¢5 �m YZw ZZZw'z zw Q ��oo°u2io Z as Nv'ON y a a a a a a s mmmDw¢60 mo<<O¢m¢wwwJmoowx2d¢�K���Oop�xlr`i JwJ OwwJX¢wwxZw O ra otn rn x aaa¢mmmmmm UUUUUUUUUUUUUU UUUo°00000q o WWWWWWWwwwww4 mWpOa¢Z Q vOezw,w 3 w w¢m W w > w�wax x a Ws c73 zizl O c� wUjO 0 0 aY¢w2H0 S m0wxwl�oaF-� amO,li-JJ00000a>3 ml�li_�Ztn3^w Jw 03 x Uooli� wo¢=wz¢a¢ammmmmm U UVUUUU UUOUOUOUOoo coo0 o0°o.w.vWWwWWWw ww Www a3<=M,z <L } } vWi > 3 3 } ° z a N MW } a z x o > y w S a > > Q m z o a ., J J J > W o U W U N 0 > F zp ¢ a ? > > > c7 w uNi O 3 0 x m a V lWi F z 3 F Q wI F z 0 ° w 3 o x a F a myl ° m m ¢ N 0 0 W O 7 O > > w m Z Z Q O H O w > V w d N > 0, = w Z U J z ° w Z Z Z Z O Z O m (n Y Q In Z V U x x [� Q Z W O O F- Z x W U Z U N x J o w z Z w w 0 0 > 0 x 0 U o o x F ° z d x x w z Q U x m a z z o < aps a ¢ o J o w 0 0 a o z x z a o a m m x a w w w o a o c� m z 0 o a z z o 0 z a \� ax x N x r o FO F� U a w 0 ¢ ¢ > > w Q Q > U w ° z rn o o ° m z w 3 w 00 ° w z w m x w w x N a O U W fn m > > W Y z m N W Z U F Q Q N W x ]c d ci w W Z x ~ W O w a w 4. N x N H >> m U z x N = Q d a0 tL a a d Z J �w Z a s OJ 2 ¢ W x 7 7 W a W x a s W Q O O OJ O x a = O x W x N w x O Q W Q a x a F- m a a a a w w 3 w m m o c� m m 'w' a a a x m x o a s a > ? a x w x m c� ? a a a k x a o c� w 0 3 c> 1 im i> O on _ 5m L LLr VI N z w w 0I.� m W N Q ��/ O w z o F Q ¢ 0 3 0 o N O w K F O Z VJ z _ 0 J U z w w z 0 (a a as o x w 1OL� ujCO3Q3 mclw m o w O rn 0 x N W> 3 x ¢ zF Z z a m 1� W W Q(� ~ o z x z z o cFi� w w m w 0 o w r- wi F F x a Q Wx ���wOQ U J Z m a tFn F z N r w w 0 2 0 0 0 ¢ m w z a mw ¢ �w rR z ~O V QWWmND-' m Q o z w L) F rno Z3 < z z m m xy� x -� a 3 - r� c°i o� > z z m a Zw¢� �w0 J w 0 a o LL 0 �+ o x F- 0 0 3 z o 3 °0 x4- x0 a x w 0 0 zm ��0 L, Y F m ¢ N w w " w 3 (y� 0. Z vNi 0 O UOOUr ¢ v Z x x ~ Z ��,,,II F W d > N N w w x Q w U o U w J d x c a W Cy Q x d O ° Z m O F m m Z m x O O Q Q N N W x x x x J O W W z O W 9 J Q W Of �w z a 3 w o rn 2 w > 2 m \ r- � w m 3 3 } } ° 3 ¢ �y xwJI �aw.II� wx x� to x > w zI N a 0,,C:y W �6 < U Z Z F Z Z m Q , Q (n Q F- I-Q 1-Li Q J_ J_ J_ J W. W U L7 N J d U U Z m Z 2 - O W J O U x x W w 2 ; Q a x a J Q x O O O O x F (n W I n-Z Z Z Z V) NI = a z z = w 0 QW x z wZ rz J z a a w -' w w 3 3w 3m 3w �. d = a z Ow z F U z F oz w3 ww a a < o- _0 z �n yr s z z z z z x z w �- r a r ta- r a J J w w 3 0 �jOw6 g3°FU w z � w R x a o U S� wz xm =a w w m a a a o Z a a �' m o 0 0 = x�`� oza 0x ki1 w w w m FQm� �QUW o a.� z w w 1 0 za J... jv10 �n� m o o � a 3 3 a 0 v1 O ¢ Q O w w Z ~ ~ J Z V QOZ�Wooz0Q J ZU, \ M I I I I I I I Q<-<J t.�J Y H � I I o V=)a, QZoa J w Nra3� a 3 3 a 3 m N > Cr o U I I o O o o x o � xx � � O Z O I = I W a zw F) zDz OZ¢ww�F� I z�rj e�¢L)o� 0 ;a°��zzscwn U W L Q Z O W O-i LL V)OU a-O V 0 U fn w CJ O K F F-O Z O W Q Q o ~ x Q W Z3 �W O aU w2 C//�) Kw O �O a 0 w a�y N >O w ¢ �Z Z J U w 0 w0 ma d wwN� K 3 m v� U> >U �� Z Q a z� O w xU' w a O �Y w I¢- Z j ZZ'.. -1� 2 Z�j NF-p 0 W ~4 N mT 6 C O O ¢° Z g x a 2 Wx x Z O N qy W� QNH Z-Owrw KpZ a O < o F mWW x x m o xk a w a < w wo a v N3 w jw �� o:oa 7--S i = o vw U mF o Y W D'J dx p° N O U f W ZU x ° J ° x Z� wwwx FOJJO axa<O g V O O x O W2 W x UO x Z O � 8 z o w 3 z 0ZH. m < K x wzw >a <Tuwm a° N2W p S x N K 3¢ �' an w x aa. om m i a a w �w< w o ° z aoz °� zwxwyo w a x 3 c Z w J a x x w J J x 0 r a ozz x n o m m°w x wo caiz = z a oa o _ aNa x z a j Fou U0 0w�w Kxa z ¢o w > x W w Q ww wF f� w vN-i ° w w a 0z� ¢ N a ¢ a or Ww oazm ti<- a xO J x xQ `y ag N 3 I- o Ox" g z o �' w =o0 3 rn o o J Wx� o� w°o �a oa k m F" vz-i coif x mW z J O�W cai L Eo a a a � 0 wo¢ i o 5 ow .13 o °ate Fir ag=w a z �< F w o O JJx ¢ O 2 p U a O ¢ YID w J x2 HIL J a U Z N U w Z xJw Z Z15 z Z Z ZN <- - px0 K z a f m Wx �o Sz o �= zw c~ Jo a x a a 2 ��� x x aNa c�N wwZoaz $ 0x w Z. O a Z O zQ na ° c� a�� X Qox x ° a c0i ° o zvW � - � ow ¢ www m0 mzFx WZP V w 0 a m �u MHti W Rz >a W kko w o w J w zo zo w i x o J 0 wz ='Fa NVa o xo a H Z W i= oz y� m �V WaO a om� a N a zoo fc~i �i x J xz xm xx�o >o� x wN z 0 w O w fn o° Jw v °V� xN z Jmo n w o °F worn °f5 m° o a a� .am E. zmo ow a a a W V nY c¢ o� zWi� zw� °w~i z xA F zw w m 5 w xz wF v � xz ow° 0, 6a ° a W ° F_ N z zJ wg zw, x Z a o U W a o g w o ow ask �a } z F- 00 �W mw Qc4z o < o az wa w Fw o mwa a° �o ¢ ?° w aNa¢ wci �Ad < a < �x ozFz rzz U �Nz m nF i ag ° z °�< 3zz zw i ao wz< zN xoyo ozn o �N x a V Q w° J a_ o U O o a o U ww z x 0 Zo WO ¢ W oa Wrn a¢ oa�o Ys'ms a you J 5 0 wow z o amw o< w} 0 m' gN QJz WI-J w¢ow zWz o Fwz o w < W a. �N O�J W N�Zx ow¢ U°< x aw ag kx UW w w6N aK QQ 2 0� OHO �¢a ZIUiVz aOF m Ud J K NU �Z xz � ¢za w$ k ¢nnW 'F z �m w s- _ °3 Sp a mxJJ <"a s °n w a w xn w o za N. Q w zv x xa Q z o m 3rm c5 wz oz sawo w�a °J F-Uw 0 z°a o> 00 ° Zza k� < k �Q ww oaoa °J=° oo$ w Nw = m z Z W a� x� zc5 z �w ¢ x oa w z aJ'rn wU x w w 3� F-m xmWmUF LLsm w z� x o cFia Uo �O r amo zn �m v ko ao J a 60,z z�a�,,lIaz �° o <a F m $ o 31- N5 JJj OaQO Owz N ZF W�j w0 Z2 wm NN yzj �wfY xF OW H ZW an U�WO aO J>aN QxQw < JW WWx 9 d ms OW x° !Q-4 w0 J�Ja� U WJ W Z- U Z oUrL O '3 WZ asi¢ wF QQU F- Jx r O W om gW k� zr �ZgOj3��x 6W o N~ oo Uz ao o� wwo z °° �yJ' a $w �J wa° ©waw zwNa 6ZQ N aQ 3 N LL 0 Q °_ } Ua U O OOo 0W O w Z WW JJ W J'w Q U x m o w w cn F aomo Q V go U 2 8 6W. x a j F N 0.O V U N W f r x Q Z U O W K ~a w w Q w 2 Q N d ? Q J W LLI o x o° �= aw o°QQaa�N oN cw Gx m w� az i ar¢ ° m <w oo �� P-0 F,<Z ¢o° m.'<, °*WO z �� N ¢ N O ¢� wmz « 0< aaooxmw� �W coo z000 z Fw zd �w as o cwi�x x z0 zo oz as wx ook z¢z �Qw? kwoa o °a m a �a zoo VW i wow w3x0 zF rnzrn as ¢z ao Xo �5'' N rnwi o Fd °'x wk o zie 00z �z >oza x°aw� Rd w w 0 w xw wcw .0 w= CL.0 iL ¢a �z wiw z wJy wo rF `�' < o woo ¢ w� "`^ Fw w? �a zFi88r »o z<z� aaaw oo � 5m ° 5 3w m 0 ww wWQ aJQm U d a Qm6 f o dLL NQ == Ut0 3 QWO S K� cc 7Q =0 a� 0—0 Q<Q Q�w� �(jQl] d� Qm ILN 6 a Z� x 0 N M 4 0 tp r W Qi OV Cl M a Vl 16 1` <d Of .N- Z12i3NH318VNN9:i3V1N00 ONI`JN1833NIJN3 _ °°pppo Op0�h awr ;43�02iddH St7Sel9£(90Z):3NOHd ------ M `0 ON;...... '�Y 9E086 VM'OOOMNNA'I NOSISO�j o N oor5;�'ct "�' awr ME 311f1S'M3Atl HlOb:Ob6: p _ 01 u zl30 :03N01S30 m m N WVM 'NOIDNII1iV 0 ~ W J N011dIa0S3a 31Va 'oN o 8 ONlaiina - )iatld ivikasnaN1 1NOdUIV NOIDNIIHV w ~ mSNOISIn3? ° 130 :NMrIG dVOiH INS St, 1N`dN31 103r061 �; N a °z � Ln.L wm 1O� p w Ld U = w Z I- > Z�a a U ~ 2 O 4! FS wa $F U 3CZ70 z Nor Zw0 0 rya j a 8Wz Na a N o F Wo o wjO z0 5} ~ W Ozw O W J a 000 WN - N W 5 } ZZW W4 wa'W0 O m ra W N Z pVU mx O 4 N U FCL mk �m �aNO m HMZ Owu j U! OU } aW0 Ora JJ j ON W �wm U.N.. WOJQQ a'J W 0 m OM Oz a r m W'nw ¢� a'44V1 2 Z<a w U Q �yG�y,� mW¢ aF N p W a0 W<5 a0 aUyzz z2 Z S z Z wO 2 F J a a 0 U N < J N a J 0 0 d O a W F �H < o N Q p m ~ N zi =O W �0 O J a N Q Q Q K 0 0 m m K m }`woo 4 �o J w naQ 02 W Q o a 0 °O 0— v �f-' Oy!Op a Q 7LL0 O NO Q m O J 2 W Z Op Z V) 0 p� I- Kv1 In z z Z �O� 3 wzno zo J WYW oN a N W o �� ao� �Jn Wa-< o0 W awza W� Q Q <F_ O D w 6 SN OF Opp co- W �J y pOQ7 U m� m 2 aH m0 H p ZO V)z I'6� 0-,1 50Q�m YU In W VI Wm- W JZ U V! dz0 SW O W J m a]o V)F wm� OZw aWQ� az ~ In m Q LL 0 0 W a W Z Q w 0 4 U O Q 2 Q K �O a 0 Q WX W W 8 Q N a 2 w 0 m y (n W ~ zFN s N a cpzz QO O UU Z> 4�zw mN� �OxW �m �� w-Q J �'� a zQo 0 a ��W1a W a xoa a }O wz Zo U QO�F+ = ON Zp M W" mw Z 3 Z Sop 4Z 5Fa �<Z2 00mQ p� LLJ W N a J(~j7W N >� 2wm =0 z0 K �Z Fwa aV w� as 0 z W Jp Oa JW '3 O a ~ INN Q aZ00 YN pKKw Q Z¢W 2 ��//�� oW `n'mO¢ �� za k'No w� O < 0 0 mx N :wgz`F-' z~w c�ik'az �w '^ m W ¢ V/ 5 00 O Oz a adz a W� O a za az- a W� Qzwa w V, w ¢� z W 0 0 00 f- O= zo 0>: 3 z.I nn o z z 3 x w 0mp ��ma g� o ¢ a zzaw as ao �z wO oO xo < a z� XY ��mz O J� oama oo W FW-N 2 < F— d =waa oO 03 00 Fm Qp�u WQ w10 Sri NO W ¢a U J O�<0 Q 2Z U3wN a4U Q F-Z¢ VI O Wo Oaaz Fa aN zS Nz Nazo oN as oaw Nw� O �> z} QyNz <z0 mcJJ z Owo O Z !/�O Q O W mz y g0 aZ a �- F a'F O �W�i1U mW N W 671�W LL H 0- J z N a-W �I,J� Z�yJap Ua wa 5Oi >Z mZ Hy0 Z �YUFi 5UJ � Z O H Z papa Na JW JF J r-a'I� F� as JQ Op OX �Z ZUaJ JQZ SU5a OWJ O O z Z JKJV7 JZ00 Q00 QO >2 02 a'O 2- JO OWOO Ja'O JQWa' CLaO J N LL 0 3'V1 z w Q� m N Q 7 Q Q 4 N 3 m: 2 N 2 m U a� VIA a m U Z 3 m Q O U a m O O a 0 4 U J O x z •' of d N M 4 V) Id I� a0 Oi a N� a 4 � W O =3 OF ¢ V N M M M M M M M M M M W VIn7 w J ¢RtiS z h Z Z U J W O w U U W F W U K m 0 } vi Z U O M S 2 U qS 0iw 2� U O w � N O plOm z K N 0<; w 0 � Vl �¢ z6 v) z o m o0 0 d r N � � W ZO �S �¢W_ Z�V) V1Z X I- Qa'ZJa N ~=5 W O W ❑O N w zV1p0°7I a JW a LLI W W Q N Z a a' U J W UO- m O J r O Zm �.Z 2 ww Wa' a�y,�U _N O j F- F 0 U_ H H 0 Z 3vU, mOO�O�Z WO ZVl 6 HO �� ZZ > U Ja- Q WW V/00 O N N _ > a QW~ Nw U N Q mJ H>a V) N 0 WO U Q .00 0 Q vW'�00 ZUJ m�ay'I ~ mY aJJ H> Qa' a J�HJ aQQQWWCL HQ Z�OLLZa �F Z D.F OwZ`amZ aNa y J~aZ pQW>J OpZVIr W w> Lm, aJz OZ OF N I a� OJ J N UWm Q Q QW� Zz aPi,�N,ZCj w3 J Oz am�UQ� NOp FzF Q mSpQ �Syzwo9 ¢mK C5 O F- Opa N>Z wF to Q JO Zz tn z�> in z >Zp Z m m W OCj O W ��VIUHfW SH Q 4.1� UQm O W WF F 3 OOF� OW jfnU N2006 Q (aJ 7z0 z�a �nW O H mZ gz �Z0 V) Z 20�' V) 0 pU0"VO J 0k ow¢w� aO v2 as m25�o O wza�yylI LL W wwo ON wwm W yc2i a Z ads wZ W gp aZaa Fvi c2i ¢ o 2 a��U w 2 o 4 Z 0ZU N ','' Vi ¢ K F O aZ C73 V) z F O o w w >w }� w a zox z sw z ao� a J W �� wz ao 0 } za aoa o Wz z U w cr cn z QHO�w O a SO ~ J H O <QW o O`� w a KNwa > 0O a0 m d J 3} J aF wO H Z m U pN OZW x O2 O Z�SOUF a' I- w Za' Vj i.Yv aZ F� a J WN gZ a'U'` �a1 O a OJ J 0Qm 0 aF ZU 0 0 U ZOlyl¢ LD U a'W��mN f-a am �� a'=0�' �z pU >Ww Q U pp wK a�N aZO'm > >�0 0 > Z> W w O <Jia ZH mJOw O 0 0Ij W, U m W 0=L)U_j WH MaN ZW az s+0 t zx- O U JJJa' a FO ��y,,II K J a<25wOZ 00 J 42 4 7 xV)Qa' �`"'O> QO?��O wa' J ¢QU Zam JQ N U 4J ON w0F F z� 4U0 "y y� p J() J 30aW OO UN QQ U� Ua OWK aW >JXN a 2 wQ�7Zn axl-a'Q WQOJZQ V- Q >OZ �aW > m W J OU Z� aZm w - Qa'z N WQ I- O W Z O UWYWF ZO 3Q H2 M0 ZmQO z0 JwI�ZY O 0 U�2UU W4ZW> Ww450 mIN 0W0 v5H a N Q ZX OW 2 Z Oz Z z� - MM XH W Q U W Jww ��11 v Z a W O O W = O .� Z 0 W O =O(X Wmw ZZZz H WOOS 4U QF 3 V) >U O F 2 �J 0 WZ MU a w In z (nK In In N Q W Z_O'a.�mDO VS �0 ZU NO aV70W Wa Z'�WN W �W aQV1Ja. OR Z-w 2Yo0U O oa a�o�nnQ 5SO w0 ay z '� w0 Q0 wLn X,0 o NW aW� a �w O ZZ_j Z maaX,.wU 0= z �`'a =OUWW a �o �W \ a ¢� zco�sa amWa zw�X a o_w aF� 003 �0 '_�' cxi ��' oo XLL �'�"' a w� a�O ter- O_O_oJ.Oo 2 �MM=W Zo Fo ¢ zo�a aJ �z°�Q m as marr¢0 v.0 owV dN��W < aX m3O ar0 Sz �W a > z �O a�M w OU oom oad o5 ~ ~ (~j~ Jdp2acn _ aN m� oO a.a}m aw f oxw moz W wp.wm U �w 0"oi z� wz Jln tiz xaay O Sa Swa a am aHQ¢>aX aw �v acw waa0>> rnzz \NJF Ja4Ww W aW 9o=af-'' a wo zaCO vita �a >� m O �o oM WPM 0 w� oa= No mz z Z z�zz o3OWvizLL aF mW z Omwwwz w IL w �o awOO�3 w oaa Wwaaz z '0 Z. <�Y OIR ¢= w K x_ �� wO a¢rh a a¢ a�0 wM 02 05 0 0 �� Oz 30 S Oo Sa amJ o¢ S,V) Sw aa�z¢ �5 zz3 Nvi��'rw aw :D vwiz Swp o0 5� Wo gN YQ z¢ IOIyJ�M a �� Zoo Nz zw _j ZZZ¢Z m p V>0 m K W 0 O O U VI Q J U p.N m�m p 2 0 w ..W N a J a W Q O O N Z 0 m O Z z W D g r w X O W 5 a K Q 0 K K Q 3 M > I,Nj 0 a K Q m F F w} a 05 OKUJ w r- a- ZnW ow O z� g aJo aw a am�"'n N aw p O O mN ONz Qzp00 5 F Wow a�z Oa aw 5 ¢ MW zri o�J a� Oa Q0 am W p0 p0NN� Gi�OWUT JFN O 0Z_ }Oz_xa o ¢� U Fw} zzo moaw w rr m aca In No a� F U QZ wJo aM m Z J �w O OOOOO Z�z,z,,ZZWwa 030 Kfn U� I%)m 4V1yr W^ V)z; V)W J� ZW �W mKJ W aYYJ y O w Jza F on a WFQ- aHd_ W Q a.Z~ U_ QZ aQ2 5U OZ W NNNNN p5acpaao z Q \rvp �^ aO O O <w azsQ sx z_z_a d oo -O moo Nz az an w o N W H cFi m 00 zwa a� Na pw0ozoZ az oNoap ° ¢o n�'Owa xJw�Q apmnn0 ak �z aGQ� W�U Ww �a � f w°aa W¢ L'i � Wo zz wa �N- w OVj v7Qp: ¢OS 3z F Z�azF.. O V3 N z zQ�aa p.p_aw �i ztr�W QQ JJ 3wvi0 'WX UQ w w� o Itr or OK0 0 0a' wWz Oln 0W ZN mcw �U� �O �z ao3aa� nF w aJ � �� �cxi a aoo0 �� of of azw oa �� v rw Sze 5 Soap w �o OOz 5 zO U4 4 Z- WO WU OU OJOa m QJ aNwO a�a00W In a'Q I-V)a'O NZ 00 JJ J4 Op Oa. OUP w 4U ZZQ OTF a O a O U�-W O W W O p W Q J W J p O WIy� 2 Q z U O a W Q Q Q 7 O a'J J J x 0 0 0 2 O W O Q Q W J Q z Q a s a'U O W U O O K a' W U 3:si UQWa' 2mJ x.- >� Um z(.7JZ �N N>QN �� QZV)Ka 33�2N W4Q44W az �N 20aN OUO KW » O QVI av 3 a7 aQN p (YQ UUO a� am In b r ¢6 to � � � � .- N �n rMef w O 00WX ro m y �� aD f M N r0 M aD ID Y OW�W� W W a Z J o 3� Ox w>U z �w w�4o m 0 W w �� 4 0 boa oo zkz Wm } w o Nab id �> az� a k o na o O ¢r Q 0: (X z �Q z¢vi p a V) ma U W Xz mR� m r"� g m g i� a� Z 3W as3U M� m z o < NMIE Z a as >>a d d d a d c d J a 00 1- Om zQW, o a s xH a } a ma a 4 0 U 0 g z x r0 0 <a o3 z a N as _ 0 W W a a `wt� oaF vNW w N<¢ �N o a N ao z W O v w J F Q J m 0 W J O N W S> w Zn Q W m 5p V)0 F '� J fL Mn n3 aFa zw w� �wo cxia w� n 0 o w cwi� W W w �\ ; }O xOz Om wz W00 na as �' z z F a Wp a J 0 00 0 N M a u m as g ao 3O m0Wz_ zx xW o� o a �W < Q >O Q <_ �3 n �� o2 JO �z W a O wQ >J SNP X< J > 0 O W z 00 f0 �N WV~IV Um Q a Wr LLJ LLJQ QP OQW .X Nw jKwO m5 K N W aK Q ��./ wW z �w W z z ZW oww WZD CL N N a..4.1 O m = HW Q Zi W J` �� w a M N m m m a Uw W�a 0� 00� HF' < zp = Y N Maw as \ � J a F m c3 N JO as DX H �W gQ r O0 zzx Q O aw i 0 n VFW z a Q 3 zo m W ?�v W H_O O0Q'x Zz oJw 3WJ N� �µ U � O N f aZWz ZQ U < ��C'0 I z 0. 0 Oj d L�J a ¢per } - xo m 3W aW NSW Nwp F `/� °x�^ a 4 wa W c W �� Z W 0 V ww�y,�o W O U W V m p Q�7 �/J N Q m x Q N Q rm O Q OZ �W SSLn W O O O O M Z Q F W W� O Z Q W pv 2zv >cW.7 In N u1 0 O 3J UZoZxN wO 3MO VOO �� z F F W z o0 0 0 /�/^ X- g M N J Q UQ Ka W 41Y O a 2 a K W U V/ _ <a UW 0 0 0 0 0 0 O �2 2wF0 SW aaN a¢a Ofn O U 0 OI p z ZrI) OW r Z W J O ON ZO JK w aU �a "'m a N (~W� a'� J4 F z_ Z ~ d W� OO �a UW JO JNO JZa a'a �' J a' a' K a -t r W J O7 OO O O O Z W3 0a ommm Ow oa0 wQJ a mO C' i m m ¢ a O W N a L)Z 2 0 z9 / Z U� WU O W V) OF OOZW Dm O O ONa z \ \ \ \ \ a W 2 a, Q UJ aN u U OO WZ N\Or O�J O�O UU J Q > > > Z J m w 0 Q� NO U }� NQ aOZU �a �4W �W ai0_ S a a a N ~ ZO zz CZ �A Z w MW 0,2 yaws WN MOO 2�m m ZQ m 3 a z c7O ¢N 2 Q V�/ /_/^^ Jw c7 �2na r-mz IX w w wvi F az o 4 a z�" U V/ W RN m N Op a Dp \_ \_ ¢ 0W W3O �d M0z 2�`'XO w $ Z a �J or- J 4a zNZ M \ In M n I J 0O E;< mw OJ ZCD a JQM JQ4 W O,U 7 U U X a J 5N QFQ $ NF j Od_v 0 aU NW Nw- JO Rz< Oj>W 3 a'N ` z Q 4 a mZ 20 In LN w _l za N OD Wm �w02 aN EX0 a 50 s W Wd �N 9 0 a W. N �m 0Q F 11'� Q L)0 n.H zF��� FV) 2L- 0 aa0 a wO V = p a W 4J a �0 W Vl . v�W '- Zn 0 x 0 J W W J WV) W f%i 0 a Wa W Q O Q W S 4 j U k z W Ma as � O z w X W. �U W �> Z N Ni d: Ifj fd I� a0 U N v a W Z p Z x r W z a' O d l_ y �Ya p: O a K U OU V)- U J Q aCo a z a a m oN ¢¢ H w (7 �Owtwwww W < a w wo o ? O Nw 3 � a M Q 0 0 0 0 0 0 N w W z Q W Z z = Q O w O a 4 a w F a a a m w u! z m m a 0 VI O r•i a0 Fa O I-'' F_ W W W U J O 0 IIJ.O K a'0 p Q z Uw U W 1- a Y Y Y Q a N w 0mw OU ZO Q0 In Z J Z ~ U J ''^^ O U U 0 N a a a U kJ z w 0 0 m O w m w 4z < wa a VJ rc z a a w zR w p W y 0 0 w �O p W 3 w 0 Z Q 0 a W a v- � J F- O D 3 0 w J z oa wJa JZm9 �Q> > Oe pa-_ ro_Izwwwwww Z a F_ �p 4 a a az w� vQ~� z4 om 0 o wwa O O 8� _ > O } w o o w a. LC) xoa a' 0 mryU Omw N LL JN 2a. OmOM7 asw a' x J Q d (,�� 2 XV7O JJ z 4ww 2 a O O wrr0} JO aK w O F w W W m a F U L%-1- aH WO F0 QS r =NaOp 90 0�Z(L 0] m 2LL� U aW Q m m m O Q Z Z <O ~Zz mW Q N 0ZQ 4. F 'T�' O a r•n, < m m a' O v=i _W z $� w a Ld W x ZLO o Jarn F_W*¢ XjU V NOJ V z J J m m N p OQ� -4 2a F� O NO aa ��J11 4 o Q m J3 a a a O Q J rn o 0 U ¢ } N N N N n 2 OZCp 30 JN� aka O N QJ N �J Z W W � 3 Q W 4 OZ>>. V� QQ Q U N to N 0 N N N O 0 0 0 0 7 O Q O } Z m X a q L _Z Z_ O U Z w U W J Y 4 Q n. a s n. a a J J J J J O J 00 O m Z 4 a 0 $O _N VI 3 Z W 0 a Z N w�w a Q a f- K 2 O U LL 4 LL 4 J U Vl W I,J W O W J � 4 VI N 0 0 m 2 r O z a F- FF o00 000 \ zO" w cn Q W O r � F xa p_> aaz In O m100 W mm o\�\\N� aO ow Npw Oa w(nn zz 40 koQ az- Q 3 N z O a Nv) NV) zN WW WXO w� VI a� U pQ aamm = _.._ F a2 � a z_f Q3:LL OQ H n� ® a ® In a a a 0 0 0 0 p z dew Ow �a Y �'00 �+ z z ��^a^, W o w W o �� o k'O < z= LL J J J J J O W K U N O J}K Z_ H Q w O a s p. 2 (W'J 4 0 3 H Q O U a N m Oj f 2 f J J J J ��JJ X H p 0 W Z a v 1 w J d a y.� W a a a J a a a a a a a9 Q 3 W O O >m 4 V m J m = O W W W W W A^ / H ~ 0- W W J O K N W Z m 0 p Fi 3 0 a y Z O W O oOc� � wc� caoOpo 0 �i.�= oz O w w } ¢ pa 0 Q N In W mw O o O w z0 op N IA 0 N a0 tp ap a0 N OJ +�N O J w U v) U ?.Q as a s a N O J m a Z j 0 z Q d z O Z a Vi O NN N N � O ZV)Q zz0a' SOWf JJO 0000>a W WW Q 0J ZON O Oa Jr00 a3, V1 Q0 (n ¢ N � dO ywJ �2 �°�7Oz W WONT an oOOOOo O O0 3 r Q oaazarwOawZnF S� -H z m � z LLJwaJ aN W In �z 0w oa ~ a m N rn w Ww=<� = o} I a= a a p 04V7) WH NmwW ¢MW w F z OO On = ; a w � � OmaroaWOn �JOn 0 #Orin Q J 20 �< o0Swa a ass a z �?�� �o � dN rw O O W ak z f o �NOQ�z f''< azz z J wm v0F a w aQ Jy" 3 oN�cai zzW O a aoln oyy ¢O ¢0 < w ¢ < z w a zJ on a3�z 3c� o4U o a Z N O�> 2OJ f5ON} } -a� w a wM W�� �K O 3Z 3F J f �.� a Z J ZQJW ZQ9 Oz Wo O W Z3W O4 wUzO O JN0 w H m� z 0 ZZ U 0 O 10 p W a 0V)p Oy W7 ZW 00 rn W w Z 0 0pJ a a�O z aar m z " (V w of pp r W o a r w x Uz Qzam w 5a wa n o W }wz m zWJ,az a �00 J W0 < > Fo F0 zN In ~o v m N wzz4aw} Nw za rNi �' m O J r N mOv ° z n O J o�w a � mwm'0z�Low a <z <W w aw W O o z �aoomsm aw o a ly w W V) ra w DO O a Ir2 0 NQ xU O w U a N1 OoO ZQOaF U0~ZO MO ww Ua30 Z w a g g z w z 0=z 0 w zcc mw Vl m O N w O O 2 O $r z wl- w OZQ ¢w ® as a 0 a a zo o N w ur 3 WW z �- z z z a o In o 2 0 0 W W Q z O N0 0 0 >0]} �m ¢ oaW Z ��a 0�y,� Q aU n � p w Q aX 0 x- F x a � a Na Fz F` JLL J = W w J a'fm 1. �-H a > W a� O O wf U x r 0 z 4(n0 aQ QO 0W J m w W a' D:fz ``1 U U cJi Iwn�O L) mJ�oz< ¢�¢ J H. a �z �� a DQ m zW vw w z z s� moo Ow a': a`p wvi z D J K a K W --� N Q Z W O O Q O a ~ d �tr J m Ina O,k >Q Z Z K N WJ ZF O 4 Q M WIyI N Q a } Q Z 00 O v) W U7 m �Iyn,� 1- H , p} O S,� Z �WWWp p (n(V Vl > Q >O 30 3o Q m J F W O ; a z a az K F-� U w x j ¢ 1 ? 3 3 3 = �" WK~O� w p j a W W J W yl a ¢ �s c N m 0 L,W 3 Q H W a J m Z w a Vj 4 3 o a(n ?? r J w J z w3 viz wW as o o a Zw a F z4 3 H o O a U cvo N V`�' 3 W x vi > Y �" Q O OOo am ww....Q 0 Om'o c Qw Do L) =W a o o d m 0 a z z0zzz m a0z ap a o_ � � u zJpo '00 as wi O a r O con J zw 4F amJaJmaa F 0 QO W W W Q Q 2 N W }W Z Z Z 4 ® 0 O N 0 3 0- a W N O Q-O O U Z m O O � (,� U U U W a I > Z a' 2y zz mpp00tp O H W y 0 O O m U J 7 N U O g >ac.� a s N O Q N K Q J VI O O 7 U < Y a w Q a'I- O F F F W O m Z (� C W Zn V)N N K N N W z a 0 W z m Q m 'w a(~j W 0 p J Z OQa am2 W3�y -Jaawa za - z�o p] W } } 4 W VI W W W 3 O WO WZ >a000 cw r�ro z U �o WJ oa o� o° az G w av2 °z a a o = apic d �c5 as =vwa a < z z 0 W Q m x x z X w W 0 0 O O 0? W a 0 tr N O Vl V) NO O Jw Luw0 w Ym� a Q m > p c } O W Z F- _ = J J Q. w O O Z N f�1 Q In t0 1� W Oi o > > k' Yc2iwQ n nzz cn c 2 cz J vW mvz- Yaaw � � w > > o w �O o }az Z.= N M IA tD Z 5 t�j• m F V ap 2 a <Ian gi aWr 03AOaddV Zla3NH31aVNNnO:iOV1NOO ONI`JNIM33NI°JN3 EbEEb9E(90Z):3NOHd NOSI80� y 9E086 tlM'OOOMNNA'1 0 o C W 0 ram......, N w 0`�t air ZOE 311f15'M3Atl HlOb lOb6l m N J W o C'•.� e 130 03NOIS34 m m = z �pd�:le1 VM 'NOlJNIIHtl o t1 V F NOI1dlKS3a 31Va 'ON °opo 13� 8 `JNldllfl8 - JIHtld ltlIH1Sf1ONl laOd!!Itl NOlONIIHtl w a w J a fA w SNOISIAIa NMVaa d`dOIHVWS St, 1NVN31 1�3road o N o, v ep N N N N N N M z O O z Z Z to F �z W O r > Q w LL J 3 z N Z N N W N O m to O O spy �i.l N U m Q (n N Y O O a. W u7 X Z Z N O W In m Wo N w W a CL 6 O N J O Z O O O O n O U U U m z m g N o W En N M Qz N N m ¢ m O m a! U w O m co am x w Qh Q K W w w oZ o pw U N J OJ aE Q 9 w H N N V N N O �ir..IILLJ < v J 3 O Z Z x U LLJ N U N U,^ a UN F V/ J a N N N U 3 Q a x w z W z Y � c U O Q J w O G WLLJ d Z H w W JD W F¢- > N U Ww w d z W Cx! J > w z LL J J o g o x o = ULL m Z W¢ a W x fL Q F- U U W O C// N Q O Q U w a (NV)LJ U O QN J a a = U U W Q Y Q a U W a a a 'x LLI w Z Z U m C� a w o U z z m m <o 3 C m co¢x Q xx < zM z w w LLJ o m O � o t U U z s g a Q _ I� O a O O w ¢ ~z z Q W a a a c� HW_ Z Q wa 2� w Q o m m z Qa K J ¢I.i w t� ¢ ¢ U N 3 m a W 0� ro XLLJ UN n ~ W a w ow�v a a = z x MEW Ld J m� a ¢po O4i N ¢¢ N U Kc In a Z y m� v z m az w x w W O Za n W s i z k Q w y ��a 95 o m W da o W Jw� m W y¢ N N F J M,O W H w Z N ¢ Z KWZW� W W (N/1 O N F Q w _ D z_ Q W Z O w 3 o a wvl¢a Zm N w O N d U Q W Z W Z U J CL U Z m N(If d d 2 ¢ a a F zK N Z < w 4v+�1 z W �Z 3 a y Z) of En O Z Z Z Z Q U NJ O W ¢ O¢ Z 1 ¢ Z F_ Z U� d ZW IL N d a O J O ¢ 3 U J U0 Q a v~i m o o z <am� a W z Z z W n p o o m O K W > W N Z o 3 M ¢ Z O Z chi_ n .�I ni � "'-I � v n H F� u x to Y LLI O h O O a O Q m 3 R b C�V N M Q Q ICI b n W m Fi UU � r u m M O Ck T Z a g� $ v � o o .• a o ni m � � O 5 N ,r � 2 n n M a A n n U � Q e-� Jp qq p �j o o Z Q v, C f�+ G N [7 t') 7 ✓� `O h cA CO 5 C i '� I� � J•' G M � 3 N Q N 'R N � V 20 II II Z 4= p a "� CI O (1 eN N e� h = Zui N 'G a " • w N K', m '� A 4 a j7j yl N a 4Tf N O. N D '�O YJ V' �i N N Oi 7 N N q v� W N w I� cd I� � � Xi S ffi � � � C7 1� r Q \ II 1s. L all m r ^I a O O O ei N C" CN'1 M O 617 J w S na o H > I I I I IyLL N `� �= 7 a-.- 'r a�N $ r O G O e+ N M IIf �P�•..�� 3 `� � W 2 O Q Q< u1 W �g 7 C 2 � �CO N 'P V' N N QS0 w `�QpIg f�' .�- m :, N N io �• iV Ai a Fm L b lV :.I w Y h 2 a °.. i 25 25 z. P 3 m w ' ; a s d M pO0 awr ZLa3NH3�aVNNnS:1OV1N00 ONI 4JN1833NIJN3 O°O° =OJAOaddV £bE£-V9E(90Z)3NOHc ayy� O g£086 VM'OOOMNNAI NOSI�0H o N O ON-'........, ppr�?:•`�t ZO£311�IS M3AV H10V IOV6l N! our �a` cl :03N33HO W W co 1ys ..�� o°pp l30 03NOIS30 tlM NOlE)NI'latl o S o O NOUNOS30 Jibe 'oN °o ° 9 ONlalins - )IbVd ltllhllsnaNl lUOdid[V NOIDNIIHV SNOISIA3a °OO pO° :NMvaa dVDiHVWS St' 1NVN31 �1oJroad o d CO LO w a a F fW/1 O N U W J W J p Z 0 z v� 0+ Q f 3 Q 0 o J o F W W o d W d p _ > OS > o W Q W m F- d li w W 2 W N Z W �y>1 N Z W X 7 X Z z Z J J ¢ > 2 J J > 2 J ° W d W Q Q W H o z z 3 3 0 > > > o > > > j z m z o a Q 2 Q o Q 0 a c� O o () J LL Z J J Q m Q n Q Q N 3 2 2 N N x X Q Q J = O O Q Q Z Q U O O^ F- W m O O J O d O d N U N Z O O M z Z O I tp W N nD W N N O N N N r r M W W ) F- Vl � N M OJ Q N Q N O t0 UJ � a < Y Y N < N m ° O m Y m O O m to m F K O_ coo a 3 W W K m m m w = w z w N z w z w z Q z z z z z z z > 2 _ ° U J Q J Q J W W W W W W W W ° W F IizJ Q U F U m z Q 2 w 2 OJ 2 O O O O O O O O O X X p 4uj CO J Y m N Y N Y f E QQ W W O W O o Q n m N OS O � WW F Q> Z Q N J Q O N N N N U W U W W W W W W W W W O O O W Z J � W o W w i o 0 0 0 o m r c» ¢ x Y rc Q V U U U U V U U U H U U Y y Y Q J w N U U U K LL Q Z Z Z to 0 w c� ° �W V/ �nn m 2 J > N J N N N! LJ J N Z m Fw3 I—z� M N N d w x �f/1 Q Q K Q O CD 2 ZA V za= �///w��j N 00 ZmN FQ —/ W U 0 0W �a p F Z wmaa JQO w U F ZO=0 Wz�Z W x p z.'^3 d3 A6 N Q ocomoQQ ° a a a o 0 3 inz >rn < o O o 0 W Vi fri w w zv UJ z Q p O U' U' O O ° wp Z Y >U' S p 0 02 Oq O Y x O m O O O �O,m X F O O O F P w ¢ K K K W Z��JQgO o 0 0 w W m 3 d d a a m m0z mzw J ° m°� z z Jzoa A z Q a�JQlo O ¢ Q it w W w w w z �- � z a awON dJ J F- > Q > ° W w J g 2 W 2 g W N W O ° Q J OJU�K WS VIN W O Q z r 0 3 3 o O U W waOQO Q(n W 2 = Q J O Q W O Q W O ] K U W F O Q F W m N 7 N Q 1 N > O 0 > O Y 1 J LQ. z ° U � W W~O Q X W W W X 3 lJi CL N m J Z O Q O SWNwZ J000 O d N UO �NM�N�I�000� 0 n z Z-MNHSIdVNNno:iDV1NO3 .ONI 4JNIN33NION3 Opp°a0!p 8vir :01AOaddV £trEE�9£(9C?;:3NOHd o°O> ............. boo � M N�,t ZOE 31ins'M 3AV HIOV IObl NOSISOMo� NN a3Ao3Ho m N W 130 m Z p`•.d �: 0 NDIS3CI VM 'NOltJ Nllatl o NOI1diHDS3O 31VO 'ON p 130 8 °ONimin8 - NklVd IvajisnaNI lUOdUIV NOlJNlluv r W O SNOISIn3a :NMVao ddOladWS RV 1NVN31 �1�3road � p J O Oa ¢0 pa > W p U N w �Q X¢ J �x aU ~ U3 a? F � Na 0 0M Nda' _ _x V5•'I•pliw3•••IIIIII cJ.� . qw'-O� UWwa¢XO wN Ld 0 00 oza ¢ W ONN � w a- V w ¢�iF0xw V O �z w X a om W ¢XH N a_ iU L W V¢ Q JQZ HIM- �ma w Q Q z � E z 0 z W J W J z H m U w Y Z w Z w 0� J n Y 07 Z W Of }Z Z w 0 J N F w w¢O w� H m Ln U w ~U} a O >Z F- w fn J Z F- W W¢ m O pw3 o wo I3w N>� a� an Cl) wool,i a>? >wzp QJ¢o J Qw 0Ln HIVM V> Q zz� wQ 0 0 w Wa (ifw u ii a o 0 n-ice x V Mn o a Qf v na n I I �w Z Z I NF c a 3 z n1 _ � J �I 3 x ` 1 W r^ o M W� 0pa VI W ¢� w d �.ILy.r= 3� ¢N F- w a w rn� wZ 0 0 p N U w 0 J a o a z W z LLI a =� �< g 7I I a¢ w ~ p 1 tC W ' m'S N Y Q N Q z o d z �p f 1®(=3, �3 Q o vz-i W �fn 1i w W U(rS � oz� z > N_o m' Of>�p (n jN O Q. w= z w¢¢ Z W. W > 4 t7F W~ OOO O>7 3 3 >~ Z Z Z d U =Z F-Z Of U = = O¢ ¢ ¢Z� 0 Of W CE ¢_ ~4 moo a> Q_ J 0 U 0 ¢ J Qa z g wwa F-m ZZO 0J ZW O�w 0w Q J U �U UO OOwm �} .0 LlJ I-W I F-Y amU\ F-1N- OWE QH¢ 0 Q F- M Y Z N ¢m F Y ^ JZ 3 w - W Zto v= �Z¢ d Jp V7 0 a m x x N¢J x m¢J d K �Q O�F-� �w .Z7V 33� NFN QQO 0 1 >U Z U ° y �_m W w O N Ow WZ¢� _ \ =0on 11 J a O W d m O Z �d W1 <m ° Sao z 0 0 ° O o O C N Z O V/ ) U Q F- a � mO 1 LIJ W o Z (n W W 'o w W > z ~ < a Z J¢ Q cpi w 1n z m C a LtJ v) Z In Z nWn w `ON L.- J N UZ¢w0 x>F- W U mO F-a U0 4 In wa-3��.m� j ¢ Ina^w3 W¢3 ' U y =ww F0owwo ~macaw�zoJ z o==� ?M0 Z VI F-�¢M M - Oppppo � l NWf :G3A0?JddV ZL82NH21dVNNnO:IOV-LNOO ONI 4JNIU33N19N3 Eb£E'79£(90Z1:HNOHd �O��N.............. 9£oe6 YN1'000NINN1.l NOSISO�j p Hvir Zo£ains M3AV HLO7 lob6t N z a3NO3H0 1 a ❑Q'3,�, o N w Z J 130 m W d c5 O °oo° 1bis +� a3NOIS3a VM 'NOlCJNIIaV N011daOS30 diva 'oN oo� 8 CJNIalU18 - NklVd lviiiia CINl 1U0dFJIV NOlONIIaV w w Q Z w N SNOISIA3?J ��' pO 13`0 NMV?J(l dVO-L)J VYS St, 1NVN31 1�3road o N d 3 > N r w w I Q (V p I n O O gymq J N F n> N O O N _.__ w ?C ¢ [V "i�I .N In-ate N Z D_d J p' M M r (n I M z z 0 V p v) `s \,D I \ f I t \ \ o z o i I �II I I J �`:, > > >>� N N Ll N � I n p w 0 pw N�0o �_ I O tnQ Zap U' J Q N LL o N D.F Zp W 2�l=i 00 w w aQ3m zopp.�o Q _______ N N> p W W r' Q W w li W z a 0 N >OO N m N M F Q o_ >ZO_ = Ow vs I Q wWN a�a �"0 Q r' W z m> W'.-Z NL=i L-i N J R� '� W:m 3J¢ owF J D vo 3 ---- - W Y J z J Q Q p p p i (f� I 33F OD pow . ZQ W ry OwNO p< j �UD `J II (n N Q W �S N D_w \ w OQ� mwaD w F- O�W `� m .\ N 0 J Q 0 D:O4 N J=d' N w G J z o \� JQ� w` U �i W Ozw0 aw=w, a Nn7-w m>- to w zQ� 30-M < D_ mm w n CV N -------------------------- N co N w I ( I I N w I I i I I I i W G" I I I: I x2i \ Q I 1 ! I a_ l I p W W c;d N Q W (n I I O O M II i I J J E I I l I I � i 1 � i I � 4 is 2iWf 7-LN3NH3]NVNNn910V1N00 ONI'DNIa33NION3 00013 �O gi :(I3AONddV £b££'b9£(90z)i3NOHd .N............ 9£096 VM'G00ANNNA"7 o N Z ou S o�� NWf 431103H0 z0£31U1S M 3AV H10V 10V61 NOSISOM a \ d J ¢ g 130 w ~ m J G3NOIS3a VM 'NOlEJNllatl o IL N 63S2G 31VC ON o 8 DNlo-iins - NUVd ivikasnaNI 1li0d!!Itl NOIEJNIIUV CJ D a w dV0laVW8 SV 1NVN31 �1�3road o d SN0is� NMVNa ! J I a I J I a 3 UX"=0 z D z c / U � 1 m z O N z a Ow Z Ci J U LillU . N d F- O d to J _ O Q ¢ w O w �O w �. , I. I 3 = W> w w 1. ¢ �J 1 W N J Z ¢ ¢ Imn wm� ¢ OF U O N O J U 0 :0 / d¢N N 0Z owN ¢ UUU UI U eU w OLLJ tea`` �� z c�iX c�iz > o .. o F-z o o_ o ----- d: ~ ono w¢ w ~ zm z~ z w 3 3 Q N U X_ O ? _ OZ O 3 �w _ OZOW 0m z w 7U Dz W U ~ zQfx mm N Rw 00 U N d - W Q -- _ � N M] sf N '3 a p o o ........ o = Li N - � J f � Z a (n W 0 -------------------------- �...., 4 4taresta 00 i I i I i I 1 i w ! I 3 U M I ! 3 . I I I ;uC I a L— --J I I o w a Z L _ _ _ _ _ 1..,__. _ w to N I i i I � I I � i ! � o 3 U I I M II N I w I I � I f � s b Permit#: 5753 Permit Date: 12/29/23 Permit Type: COMMERCIAL PLUMBING Project Name: Tenant 48 Plumbing Applicant Name: Wolfe Plumbing Inc Applicant Address: 832 80th St Sw Applicant, City, State, Zip: Everett,Wa, 98203 Contact: Jen Scharpp Phone: 3607948621 Email:jens@wolfepi.com Scope of Work: Tenant 48 TI Valuation: 60170.00 Square Feet: 0 Number of Stories: 0 Construction Type: 11113 Occupancy Group: ID Code: CIC Permit Issued: 01/09/2024 Permit Expires: 07/08/2024 Form Permit Type: COMMERCIAL PLUMBING Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP 31052100400100 17216 51 STAVE NE STE ARLINGTON 090 MASTER 110 AIRPORT ADDRESS INDUSTRIAL PA Contractors Contractor Primary Contact Phone Address Contractor Type License License# WOLFE PLUMBING CONSTRUCTION COA Business INC 360-794-8621 832 80th St SW CONTRACTOR License 601753508 WOLFE PLUMBING 360-794-8621 832 80th St SW CONSTRUCTION L&I WOLFEPI033CJ INC CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 03/08/2024 C19.PLUMBING 03/11/2024 03/11/2024 BUILDING Approved FINAL C 10. AM Preferred 02/02/2024 MECHANICAL Rough in plumbing 02/05/2024 02/05/2024 BUILDING Approved ROUGH-IN approved O1/11/2024 C04.PLUMBING O1/12/2024 01/12/2024 BUILDING Approved GROUNDWORK Plan Reviews Date Review Type Description Assigned To Review Status O1/05/2024 COMMERCIAL Add backflow device before shop sink BUILDING Approved with PLUMBING Conditions O1/05/2024 COMMERCIAL No comments,LT&KS PW-ADMIN-GIS Approved PLUMBING O1/05/2024 COMMERCIAL PW-WAT-REV In Review PLUMBING O1/05/2024 COMMERCIAL No comments.Class 1.SB PW-SEW-REV Approved PLUMBING Fees Fee Description Notes Amount Plumbing Commercial Plan Review Table 4-1 $698.84 Credit Card Service $20.97 Processing/Technology $25.00 Dishwasher $15.00 Drinking Fountain $15.00 Floor Drain $60.00 Icemaker/Refrigerator $15.00 Kitchen Sink&Disposal $15.00 Lavatory Toilet&Sink Only $30.00 Plumbing Base Permit Fee $25.00 Plumbing Misc. Not otherwise specified $15.00 Shower(only) $30.00 Sink(bar,service,etc.) $15.00 Toilets $30.00 Urinals $30.00 Water Heater(Tank) $25.00 Credit Card Service $10.35 Total $1,075.16 Attached Letters Date Letter Description O1/09/2024 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount O1/03/2024 XBP Con£ $698.84 162234083 O1/03/2024 Wolfe Plumbing 162234083 Hannah Hardwick $20.97 O1/09/2024 XBP Conf: $345.00 162696173 01/09/2024 Wolfe Plumbing 162696173 Hannah Hardwick $10.35 Outstanding Balance $0.00 Notes Date Note Created By: 12/29/2023 Emailed applicant to get suite number. Hannah Hardwick Uploaded Files Date File Name 01/09/2024 18123506-2024 BLD5753 IssuedPermit.pdf 01/09/2024 18121519-20240109 BLD5753 Approved Plans.pdf 12/29/2023 18042644-23-1229 Tenant 48 Plumbing Permit Set.pdf 12/29/2023 18042643-PIVOTAL CONSTRUCTION-TENANT 48 TI SUBMITTAL.pdf 12/29/2023 18042642-TENANT 48 TI PLUMBING PERMIT APPLICATION.pdf Date: 05/26/2026 Permit#: 5753 Permit Date: 12/29/2023 Review Date: 01/05/2024 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 02/02/2024 Scheduled Time: 00:00 Completed Date: 01/08/2024 Description: Add backflow device before shop sink Review Status: Approved with Conditions Assigned To: BUILDING Time In: 00:00 Time Out: 00:00 Hours: 0.75 Notes 01/08/2024 Add backflow device before shop sink Property Information Parcel#: 31052100400100 SMARTCAP ARLINGTON AIRPORT INDUSTRIAL PA SMARTCAP ARLINGTON AIRPORT INDUSTRIAL 8201 164TH AVE NE STE 110 PA 17216 51 ST AVE NE STE 110 REDMOND, WA 98052 Zoning: 090 MASTER ADDRESSLot: Block: