Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17601 Saint Andrews Ct_BLD5761_2026
i RESIDENTIAL PHOTOVOLTAIC SOLAR PANEL ` Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 The City of Arlington requires a building permit to install Photovoltaic (PV) Solar Panel(s) for residential and commercial uses.This policy governs Residential uses only. Other permits may be required per Washington State Labor and Industries or Utility Providers. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING: REQUIRED DOCUMENTS City of Arlington Solar Panel Application Roof Plan and Construction Documents Manufacturer's installation specifications Engineering, (if required) Type of Permit: [D New Installation ❑ Addition ❑ Replacement Property Address: 17601 Saint Andrews Ct,Arlington, Washington, 98220roject Valuation: 3699.02 Lot#: 63 Parcel ID No.: 00809200006300 Subdivision: GLENEAGLE Project Scope of Work: 4.1 kW PV Solar Panel Installation on Roof Primary Contact: ❑ Owner 21 Contractor Owner Name: Kenneth Henry Home No.: Email Address: magickstar@earthlink.net Cell No.: +12064788506 Mailing Address: 17601 Saint Andrews Ct City: Arlington State: WA Zip: 98223 Contractor Name: BRS Field Ops, LLC Office No.: Email Address: permitting.department@blueravensolar.com Cell No.: 385-482-0045 Mailing Address: 1403 N Research Way City: Orem State: UT Zip: 84097 L&I Contractor License Number: BRSFIF0820N3 Expiration Date: 08/23/24 Existing Roof Structure: Existing Roof Material: Composite Shingle Building Square Footage: 213.35 Number of Stories: 2 INSPECTION REQUIREMENTS Roof mount panels require two(2) inspections minimum 1. The first inspection is for the roof mount racking hardware to verify compliance and attachment. (You may schedule this inspection for the day the panels are being installed. You may begin mounting panels over the racking prior to inspection but there must be enough racking exposed for the inspector to verify compliance.) 2. The final inspection shall be scheduled when the project is complete and after Labor and Industries has approved the electrical. I hereby certify that 1 am the ❑ Owner S Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington. Permitting Coordinator c4nou Cq&410� Carson Campbell 01 / 05 / 2024 Signature Print Name Date SAVE PRINT Domus Domus Structural Engineering, LLC S T R U C: T U R A 1, P.O. Box 560 Broomfield, CO 80038 ENGTNEER ING 1, E. C 530-864-7055 projects@domusstruc.com January 5,2024 To: Blue Raven Solar 1403 North Research Way,Building J Orem,UT.84097 Subject: Certification Letter Henry Residence 17601 Saint Andrews Ct Arlington,WA.98223 To Whom It May Concern, A jobsite observation of the condition of the existing framing system was performed by an audit team of Blue Raven Solar as a request from Domus Structural Engineering.All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements.The observed roof framing is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structure of(MP1)consists of composition shingle on roof plywood that is supported by pre-manufactured trusses that are spaced at @ 24"o.c..The top chords,sloped at 27 degrees,are 2x4 sections,the bottom chords are 2x4 sections and the web members are 2x4 sections.The truss members are connected by steel gusset plates.The max unsupported projected horizontal top chord span is approximately 7'4'. The existing roof framing system of(MP1)is judged to be adequate to withstand the loading imposed by the installation of the solar panels.No reinforcement is necessary. The spacing of the solar standoffs should be kept at 72"o.c.for landscape and 24"o.c.for portrait orientation,with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly limited to an evaluation of the fastener attachment,underlying framing and supporting structure only.The attachment's to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading.All panels,racking and hardware shall be installed per manufacturer specifications and within specified design limitations.All waterproofing shall be provided by the manufacturer. Domus Structural Engineering assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Design Criteria: C41 • Applicable Codes=2015 IBC/IRC,ASCE 7-10 • Roof Dead Load=7 psf(MP1) `�'O i� 161� • Roof Live Load=20 psf .A • Wind Speed=110 mph(Vult),Exposure C,Risk Category II • Roof Snow Load=25 psf • Attachment:1-5/16 dia.lag screw with 2.5 inch min.embedment depth,at spacing shown above. 46056 Please contact me with any further questions or concerns regarding this project. SS�ONA!_ Sincerely, Digitally signed by John A.Calvert John Calvert,P.E. Date:2024.01.05 Project Engineer 1 1:29:54-07'00' Henry Arlington WA 1 Do M u S Domus Structural Engineering, LLC S T R E) C T I t R A 1, P.O. Box 560 Broomfield, CO 80038 ENGINEER ING i. L (: 530-864-7055 projects@domusstruc.com Gravity Loading Roof Snow Load Calculations pg—Ground Snow Load— 25.0 psf pf=0.7 C,Q I pg (ASCE7-Eq 7-1) Q=Exposure Factor= 1 (ASCE7-Table 7-2) C�=Thennal Factor= 1 (ASCE7-Table 7-3) I=Importance Factor= 1 pf=Flat Roof Snow Load= 25.0 psf ps=Cspf (ASCE7-Eq 7-2) Cs=Slope Factor= 1 ps=Sloped Roof Snow Load= 25.0 ps f PVDead Load=3 psf(Per Blue Raven Solar DLAdjusted to 27 Degree Slope 3.37 psi PV System Weight Weight ofPVSystem(Per Blue Raven Solar) 3.0psi X Standoff Spacing= 2.00 8 Y Standoff Spacing= 6.0811 Standoff Tributary Area= 12.17 s8 Point Loads of StandoRs 37 lb Note:PV standoffs are staggered to ensure proper distribution ofloadin€ Roof Live Load=20 psf Note:Roof live load is removed in area's covered by PV array. Roofaad Load(NPI) i Composition Shingle 4.00 RoofPlyvmd 2.00 2A Top Chords @ 24"o.c. 0.73 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Mscellaneous 0.27 Total Roof DL(NIP 1) 7.0 psf DLAdjusted to 27 Degree Slope 7.9 psi Henry Arlington WA 2 Do M u S Domus Structural Engineering, LLC S T R E) C T I t R A 1, P.O. Box 560 Broomfield, CO 80038 ENGINEER ING i. LC 530-864-7055 projects@domusstruc.com Wind Calculations Per ASCE 7-10 Components and Cladding Input Variables Wind Speed 110 mph Exposure Category C Roof Shape FTp/Gable Roof Slope 27degrees Nban RoofHeight 20 8 Effective Wind Area 21.3$ Design Wind Pressure Calculations Wind Pressure P=gh*G'Cn qh=0.00256*Kz*Kzt*Kd*V^2 (Eq.30.3-1) Kz(Exposure Coefficient)=0.9 (Table 30.3-1) Kzt(topographic factor)= 1 (Fig.26.8-1) Kd(WindDirecnonalityFactor)= 0.85 (Table26.6-1) V(Design Wind Speed)=110 mph (Fig.26.5-1A) Risk Category=It (Table 1.5-1) qh= 23.70 0.6*qh= 14.22 - Standoff Uplift Calculations-Portrait _ Zone 1 Zone 2 Zone 3 Positive GCp= -0.85 -1.52 -2.42 0.43 (Fig.30.4-1) Uplift Pressure= -12.07 psi -21.65 psi -34.39 psi 10.1 psi X Standoff Spacing= 2.00 2.00 1.33 Y Standoff Spacing- 6.08 3.041666667 3.04166667 Tnbutary Area= 12.17 6.08 4.06 Dead Load on Attachment- 36.50 18.25 12.17 Footing Uplift(0.613+0.6W)= -125 lb -121 lb -132 lb jff Standoff Uplift Calculations-Landscape Zone 1 Zone 2 Zone 3 Positive GCp= -0.85 -1.52 -2.42 0.43 (Fig.30.4-1) Uplift Pressure= -12.07 psi -21.65 psi -34.39 psi 10.0 psi (Nhiurnun) X Standoff Spacing= 6.00 6.00 4.00 Y Standoff Spacing- 3.50 1.75 1.75 Tnbutary Area= 21.00 10.50 7.00 Dead Load on Attachment- 63.00 31.50 21.00 Footing Uplift(0.613+0.0�= -216 lb -208 lb -228 lb Standoff Uplift Check Nhxirurn Design Uplift--228 lb StandoffUprd Capacity=450 lb 450 lb capacity>228 lb demand Therefore,OK Fastener Capacity Check Fastener=l-5/16"dia.lag Number ofFasteners=1 Embedment Depth=2.5 Pullout Capacity Per Inch= 250 lb Fastener Capacity=625 lb w/F.S.of 1.5&DOLof 1.6=667 lb 667.2 lb capacity>228 lb demand Therefore,OK Henry Arlington WA 3 Do M u S Domus Structural Engineering, LLC S T R E) C T I t R A 1, P.O. Box 560 Broomfield, CO 80038 ENGINEER ING i. L (: 530-864-7055 projects@domusstruc.com Framing Check (MP1) PASS w=72 pli Dead Load 7.9 psi PVLoad 3.4 psi Snow Load 25.0 psi 2x4 Top Chords @ 24'o.c. 0 Governing Load Combo=DL+SI Nhmber Span=7'-0" Total Load 36.2psf Nhmber Properties NEmber Size S(in^3) I(in/4) Lumber Sp/Gr Nbi ber Spacing 2x4 3.06 5.36 DF#2 @24"o.c. Check Bending Stress Fb(psi)= fb x Cd x 0 x Cr (NDS Table 4.3.1) 900 x 1.15 x 1.5 x 1.15 Allowed Bending Stress=1785.3 psi Nhximum Nbment =(wL^2)/8 =443.735 fl# =5324.82 in# Actual Bending Stress=(Nhxirmun Nbment)/S =1738.8 psi Allowed>Actual—97.4°/"Stressed — Therefore,OK lieck Deflection Allowed Deflection(Total Load)= L/180 (E=1600000 psi Per NDS) =0.466 in Deflection Criteria Based on = Continuous Span Actual Deflection(Total Load) _ (w'L-4)/(1854E') =0.190 in =L/443 > L/180 Therefore OK Allowed Deflection(Live Load) = L/240 0.35 in ActualDeflection(Live Load) _ (w�L-4)/(185Tl) 0.131 in L/642 > L/240 Therefore OK Check Shear Nhmber Area=5.3 in^2 Fv(ps)=180 psi (NDS Table 4A) Allowed Shear=Fv*A =945 lb Nhx Shear(v)=w*L/2 = 254 lb Allowed>Actual—26.9%Stressed — Therefore,OK Henry Arlington WA 4 Do M u S Domus Structural Engineering, LLC S T R E) C T I t R A 1, P.O. Box 560 Broomfield, CO 80038 ENGINEER ING i. L (: 530-864-7055 projects@domusstruc.com Lateral Check Existing Weight of Effected Building Level Area Weight(psf) Weight(lb) Roof 2589 sf 7.9 psf 20340lb Ceding 2589 sf 6.0 psf 15534lb Wood Siding 100 ff 5.0 psf 2000 lb (8'-0"Wafl Height) 1nt Walls 1 100 It 1 6.4 psf 2560 lb Existing Weight of Effected Building 40434 lb Proposed Weight ofPVSystem - Weight ofPVSystem(Per Blue Raven Solar) 3.0psf Approx.Area of ProposedPVSystem 213 sf Approximate Total Weight ofPVSystem 639lb 100/oComparison 10%of Existing Building Weight(Allowed) 4043 lb Approximate Weight of PV System(Actual) 6391b Percent lncreas e 1.6% 4043 lb>639 lb,Therefore OK Henry Arlington WA 5 Domus omIfS Domus Structural Engineering, LLC J TRUCTI` RA1, P.O. Box560 E N G I N E E R I N G I. L C Broomfield, CO 80038 530-864-7055 projects@domusstruc.com Appendix A:General Notes GENERAL • The contractor shall verify all dimensions,property setbacks,AHJ/HOA CC&R's,elevations and site conditions before starting work and shall notify Domus Structural Engineering,LLC of any discrepancies. •All report conclusions represent Domus Structural Engineering,LLC's best professional judgment based upon industry standards. • Resolve any conflicts on the drawings with Domus Structural Engineering,LLC before proceeding with construction. • The design criteria used for this project&listed on the first page of the report is based on the engineers best judgement and/or provided by the ATC council.AHJ specific requests may differ.Please contact our team if the design criteria needs to be modified. •A site visit was not physically conducted by Domus Structural Engineering,LLC.The accompanying calculations and certification are provided with the understanding that the site building and construction standards meet an acceptable level of industry standards.It shall be the contractors responsibility to identify any irregularities such as inconsistent framing conditions,water damage,fire damage,cracked,split or noticeably deflecting framing members. • Domus Structural Engineering,LLC is not responsible for enforcing safety measures or regulations.The contractor shall design,construct,and maintain all safety devices including shoring and bracing,and shall be solely responsible for conforming to all local,state and federal safety and health standards,laws and regulations.The contractor shall take necessary precautions to maintain and insure the integrity of the structure during construction.If a lawsuit is filed by one of the contractor's or subcontractor's employees,or any one else,the contractor will indemnify,defend and hold the owner and Domus Structural Engineering,LLC harmless of any and all such claims. • Any and all waterproofing shall be provided by the contractor.Domus Structural Engineering,LLC is not responsible for waterproofing. •All hardware shall be installed per manufacturer specifications and within specified design limitations.Domus Structural Engineering,LLC assumes no responsibility for incorrectly installed hardware or hardware installed outside of the manfacturer specifications. USER RELIANCE Domus Structural Engineering,LLC was engaged by Blue Raven Solar(Client)to perform this assessment.This report and the information therein,are for the exclusive use of the Client.This report has no other purpose and shall not be relied upon, or used,by any other person or entity without the written consent of Dous Structural Engineering,LLC.Third parties that obtain this report,or the information within shall have no rights of recourse or recovery against Domus Structural Engineering,LLC,it's officers or employees. ROOF MOUNTED ARRAYS • If an analysis of a supporting stucture is included in our scope of work,the structural assessment only applies to the section of the roof that is directly supporting the proposed solar PV system. • No structural members can be cut for conduit,etc.,unless specifically shown.Obtain prior written approval for installation of any additional conduit,etc. • It is assumed that a standard quality of construction care was used to construct the original building.It shall be the contractors responsibility to field verify any and all framing member supporting the proposed PV array are in adequate condition.The contractor shall field inspect for sub-standard construction means,signs of dry rot,mold,fire damage,etc.and notify engineer if any compromised material is found on site prior to starting construction. • It is assumed that there have been no additional loads(HVAC or MEP equipment,additional layers of roofing,etc)added to the building over the course of the structures histroy.The contractor and/or client shall verify this with the property owner and notify Domus Structural Engineering,LLC if additional load has been added to the structure already. • Flexible utility connections must be used at any building seismic joint. • Care should be taken to ensure that PV arrays do not preclude drainage of rain water. • Unless otherwise noted,construction material shall be evenly distributed if placed on framed floors or roofs.Loads shall not exceed the allowable loading for the supporting members and their connections. • All lags or wood screws at the roof shall be stainless steel and installed withing the middle 1/3 of the dimensional width of the framing members. •All fasteners shall be a minimum of 6"away from any truss panel or hinge joints,truss plates and/or member ends.Field verify location of fasteners prior to starting construction.All fasteners shall be pre-drilled to avoid splitting existing lumber. • Domus Structural Engineering,LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array nor any damage to downslope decks,roofs,walkways,landscaping,automobiles,pets,people,etc..If snow guards are requested by the customer,notify Domus Structural Engineering,LLC. Henry Arlington WA 6 RESIDENTIAL RO O FTO P SO IAR PERMIT PACKAGE Enphase h Platinum BLUE RAVEN Ke nne th He my Installer SOLAR 1403 N 630 E PVInstallation 17601 Saint Andrews Ct Ore m,Utah84097 Profe ssiona 1 Arling to n, Wa shing to n 98223 SUNPO WER® BlueRa�enSola 80om Scott Gurney •Authrize• • De #PV-011719-015866 +12064788506 SC O PE O F WO RK SHEET INDEX e INSTALLATIO N O F RO O FID P MO UN'IEID , � PV 1 C OVER SHEET a PHO TVO LTAIC SO LAR SYSTEM / �, - • PV2 SITE PLAN .� PV3 ROOF PLAN PV4 STRUC TURAL y PV5 ELECTRICAL3-LINE (V .4 *� f PV6 ELECTRICALCALCULATIONS y N Q PV7 LABELS PV8 PLACARD SS SPEC SHEETS � � 4- � drI a 0 a � o TYPICAL STRUCTURAL INFORMATION NEW PV SYSTEM INFO RMATIO N TO TAL DC SYSTEM SIZE TO TAL AC SYSTEM SIZE x ROOFMATERIAL• Comp Shingle AC SYSTEM SIZE: 2.9 kW AC d 4. 10 kW DC 2.90 kW AC PRGJECTID: SHEATHING TYPE: o sB DC SYSTEM SIZE: 4.1 kW DC FRAMING TYPE: Manufactured Truss 916114 RACKING TYPE: UNIRAC SFM INFINTIY MO DULE TYPE: (10) Silfa b Solar SIIr410 HC+ DESIGN C RI'IIIZIA DC SYSTEM SIZE: ATTACHMENTTYPE. UNIRAC SFM INFINITYFLASMT INVERTER TYPE: En ha se IQ 8 PLUS-7 2-2-US WIND SPEED: 110 4.10 kW DC TO TAL ATTAC HMENTS: 20 X. Cq 1 WIND EXPO SURE FAC TO R C AC SYSTEM SIZE RISK C ATEG O RY: II REVISIo s.90 kW AC Sealed INFORMATION FO R INSTALLER Roof& O 11 G RO UND SNO W LO AD: 25 EC O BEE Q TY: 0 Existing ROOF SNOW LOAD: 25 0 ---- LID LIGHTBULB QTY. 0 Attachment Only 1 SEISMIC DESIGN CATEGORY: D G INERAL NOTES ,Q 44056 WEATHER STATION DATA FC1S7 t� WEATHER STATION: BOEING FTDKING CO Q 1/5/24 'SSA G� HIGH TEMP 2%AVG: 29°C D OVAL EXTREME MINIMUM TEMP: -7°C DRAWN BY: Bre n d a n Fillm o re Digi a y signed PIATDATE AHJ by John A. Calvert APPUCABIE CODES January 5, 2024 C ity o f Arling to n WA Date: 2024.01.05 *2020NAT1ONALE1 UdC CODE(NEC) DRAWING IlIIE: *2015 INTERNATIONAL BUILDING CODE(IBC) ' *2015 INTERNATIONALRESIDENUALCODE(IRC),2015 INTERNATIONAL Cover She e t PLUMBING C O DE(IPC),AND ALL STATE AND 10 C AL BUILDING,ELEC TRIC Al, UTILITY C O MPANY AND PLUMBING C ODES DRAWING NUMBER: Sno ho m ish C o unty Pub he Utilitie s Distric t (PUD) PV1 NOW- BLUE RAVEN SOLAR 1403 N 630 E Orem,Utah 84097 U (800)377-4480 BlueRavenSolar.com 7� AC M I O r / S L J ❑ ~ y N Q ® ® 13 \ ❑ a J ® ® ® I o � 0 I .4 \ I z z � o \ I LL PROJECTID: \ \ Sealed For ��°�was�� ��. I 916114 \ Existing Roof & \ Q DC SYSTEM SIZE: \ Attachment Only / r I 4.10 kW DC \ i! AC SYSTEM SIZE: 2.90 kW AC 46056 1/5/24 .�' �CISh�� �v� REVISIONS:r" I �ss�ONAL B --- STIE PLAN — _ - SCALE: 3/32"= F-0" 0 LEG IND PV SYSIEM SPEC IFIC A'IIO NS COMPASS DRAWN BY. Brendan Fillm o re ' RO O 1710 P FBE]BREAKER [A'1S] GENERATOR FRPO]REMOTE PO WER ❑NEW NEW PV SYSTEM INFO RMAIIO N PIOTDA'IEJUNCTION BOX ENCLOSURE ATS PANEL OFF SWITCH PV SYSTEM PV MODULE: (10) Silfab Solar SIG410 HC+,POWERRATING:410 W January 5, 2024 MM UTIIITY METER AC AC DISCONNECT C T U ILTIY METER FIRE SEIBAC K MIC ROINVERTER:Enp ha se IQ 8PLUS-72-2-US, POWER RATING:290 W DRAWING= C T C ABINET HATCH Site Pla n IM—SPI MAIN SERVICE PV PV PRO DUC TIO N SUNPOWER TRINC H OR DRAWING NUMBER:PANEL METER HUB+ O VERHEAD S PV2 [ SS SUB SUBPANEL H C 0 MBINER BO X ESS EUNVAULT i PROPERTY LINE NOW- BLUE RAVEN SOLAR CHIMNEY 1403 N 630 E CB UNDERGROUND SERVICE IINE Ore m,Uta h 84097 AC M (800)377-4480 ��ZLL� rOINT0 F INTERC ONNEC TION Blu a Ra ve n So la r.c o m MSPi L J O ® QI N +- N Q U, MP1 w MODULE Q TY: 10 ,S� ems"- ❑ ® ® ® AZIMULH: 130 PITCH:27 a' O Q TSRF: 81 AREA:458 ft2 o .. Sealed For •4 Existing Roof& o sxYrlGrrr Attachment Only o awl z ❑ � O d _t X- C A Z PROJECT D: �� W �7ti 916114 '� DC SYSTEM SIZE: O 4.10 kW DC AC SYSTEM SIZE: CHIMNEY 2.90 kW AC 46056 REVISIONS: ,e�RFC�y7ER� 0 ---- 1/5/24 SS�ONAL , Q B RO O F PLAN 0 ---- SC ALE: 1/8 = P-0 A. -- D LEGEND PV SYSUM SPEC IFIC A'IIO NS COMPASS DRAWN BY. Brendan Fillm o re ' RO O 1710 P FBE]BREAKER [A1S] GENERATOR FRPO]REMO TE PO WER ❑NEW NEW PV SYSTEM INFO RMATIO N 7LOTDATEJUNCTION BOX ENCLOSURE ATS PANEL OFF SWITCH PV SYSTEM PV MODULE. (10) Silfab Solar SIG410 HC+,POWERRATING:410 W January 5, 2024 UIIIRYMETER FIRE SETBAC K. MIC ROINVERTER:Enp ha se IQ 8PLUS-72-2-US, POWER RATING:290 W DRAWING TrRE: ❑UTIITIY METER AC AC DISCONNECT C T C T C ABINET ❑HATCH RoofPlan MSP MAIN SERVICE PV PV PRO DUC TIO N SUNPO WER TRENC H OR DRAWING NUMBER PANEL METER HUB+ O VERHEAD 41 S PV3 [ SS I SUB SUBPANEL H C 0 MBINER BO X ESS EUNVAULT i PROPERTY LINE PANEL AZIMUTH H PITCH TSRF AREA FRAMING SIZE CEILING JOIST' IN MAXIMUM MAXIMUM TOTALPV ARRAY AREA(W) 213.35 ROOFMATERTAL SHEATHING TYPE FRAMING TYPE PURIINS SIZE RACKING TYPE AITACHMTTYPE ATTACHMENT CANTILEVER 10TALROOFAREA(W) 2589.94 COUNT (DEG) (DEG) M (ft2) AND SPACING AND SPACING SPACING O O DISTRIBUTED LOAD(p st) 2.2 MP1 10 130 27 81 458 Comp Shingle OSB Manufactured Truss 2x4 @24 in OC 2x4 @24 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINIIYFLASHKIT 72'L/24'P 24'L/8'P ROOFCOVERAGE(%) 8.24 NOW- MP2 0 TOTALPV ARRAY WEIG FIT'(Ibs) 470 DTT7� RAVEN MP3 0 TOTALPV ATTACHMENTS 20 BLUE RAVE MP4 1 0 PO TNT LOAD(lbs/aIt.) 23.5 SOLAR MP5 0 MP6 0 1403 N 630 E MP7 0 Orem,Utah 84097 MP8 0 (800)377-4480 MP9 0 Blu e Ra ve n So la rx o m MP10 0 ATTACC HMETNT TYPE: PV MODULES SHALLNOTEXIEND Unira c SFM Infinity ABO VE RO 0 F RIDG E LINE n PV MODULE MAX CANTI EVER PER TABLE ABO VE (C) N .� UNI RAC UNI RAC 4., N ^ TPV MODULE SFM INFINITY SFM INFINITYU ocF-I 2"MICRORAIL 6.5"SPLICE 01� RO O F MATERIALNO T EXISTING FRAMING Et[* SHOWN FOR C LARITY 2X"MIN 4� a (1)5/16"LAG BOLT EMBEDMENT �••j o IT S WTILI EPDM WASHERT T O o0 �° cn o +� ATTACHMIN UTSPACING l� � U PER TABLE A13O VE ~ (L) =1 .4 FRAMING SPACG *11-11S DETAIL IS NO T MEANT TO BE PERTABLEA13OVE o f�SC NG DETAIL E<YIIIRIORWALL AN EXACTREPRESENTATION OF �r1� AMCHMENTDETAILLE: 1/2"= 1 -0 FRAMING ORPVMODULELAYOUT L SCAIE: 1-1/2"= 1 -0" z RIDGE NoIES ° LANDSCAPE PO R'IRArr PROJECTID: 916114 DC SYSTEM SIZE: 4.10 kW DC AC SYSTEM SIZE: p►. C.4 L 2.90 kW AC Sealed For �� O�w� -v �� REVISIONS: Existing Roof & A Attachment Only A 0 46056 - � I AFC `[1 Q• DRAWN BY: Bre n d a IT Fillm o re SS��kALG, PLOTDATE January 5, 2024 � I � 1/5/24 DRAWING TITLE: Struc tora I FO LLO W AMC HMENT SPAC ING IN TABLE ABO VE EAVE *ATTAC HMENTPATLERN SHOULD BE DRAWING NUMBER ATTAC HMENT PATTIItN STAGGERED UNLESS OTHERWISE PV4 SC ALE: 1/4"= 1'-0" NO TED IN ENG INEERING IETIER Ll (1) 10 AWG THHN/THWN-2 CUBLACK Ll (1) 10 AWG THHN/THWN-2 CITBLACK 3/4INCH Ll (1) 10 AWG'HBN/TF1WN-2 CUBLACK 3/4 INCH L1 (1) 12 AWG THHN/THWN-2 CUBLACK 4JL2 (1) 10 AWG U-1HN/'II-IWN-2 CURED L2 (1) 10 AWG'WHIN/THWN-2 CURED EMT L2 (1) 10 AWG THBN/'II-IWN-2 CURED 1 L2 (1) 12 AWG THEN/'IITWN-2 CURED N (1) 10 AWG THHN/THWN-2 CU WHITE G (1) IO AWG THHN/THWN-2 CUGREEN G (1) I0 AWG'HHN/TF1WN-2 CUGREIN G (1) 6 AWG BARE,Cu NOW G (1) lO AWG THEN/'II-IWN-2CUGREIN "TYPE OFC ABLE MAY BE SUBSTITUTED FOR USE IN *T PENM(ROMEX)/OFCABLEISPERMIIEDFORIN'IERIOR RAVEN 3/4INCH EMT Exterior CONDUITWHERENEC CODEPERMIIS ORATTIC RUNS AND SHALL BE USED WHEN NEC CODEPERMUS INPHASEQ-CABLE,2-WIRE,FREE AIR Exterior BLUE RAVEN SOLAR 1403 N 630 E Ore In,Utah 84097 (800)377-4480 BlueRavenSolarxom PRIMARY PV COMBINER BOX OVERHEAD SERVIC E 120/240 VAC,60 Hz 0 15A o-PRIMARY SIRUC TURE--0 1 PHASE,3 WIRE 1 B 8(l0)PV MODULES AC DISCONNECT &MICRO INVERTERS SAFETY SWITCH Utility Meter (E)200AMain Service Panel 30A NO N-FUSIBLE (N)20A @ I©I PV ARRAY 1 n Pv C LRC UIT I o — 10 MO DUIES — ENVOY �--- 3 G 2 LJ 1 (E)200A r N I (EL) �,I S" (EL) r ————— ———— -------------------------- — -------------------C I 4 4 y (PV)20A I �� r CX 0 E I ~ C) I --------------J s" .4 I lr'L I O I w r O GENERALNOTES ` z o Utility Me to r Num b e r:85425318 - AU •� � Load side breakerm MSP.InteriorPOI d LEGEND _ PROJECTID: ► �'� � • ; , (E) EXISTING PV BREAKER " 916114 (N) NEW (FIB) FACTORYINSTATT BREAKER • sow • • r• cut,!� (EL) EXISTING LOADS SPD SURGE PRO TECUVEDEVICE i— DC SYSTEM SIZE: aw�o o•nia (RL) RE[OCATEDIOADS MI MECHANICALINTERLOCK ° 4.10 kW DC p' '• y�l - AC SYSTEM SIZE: UII'MENTNOTES EQUIPMENTDESCRIPTIONS �IsI ,. 2.90 kW AC 1 FINALCONFIGURATION0FPVCIRCUITSTOBE DEC IDEDBY INSTALLER-MUSTC0MPLYWHHMAX PVMODULE:SilfabSolarSIG410HC+,410W DC,UL1703/UL6173000MPLIANT '•! 1 O MIC RO INVERTERS PER C RC UH AS LISTED O N ATIAC BED SPEC SHEET. ®MICROINVERTER ENPHASE IQ 8PLAS-72-2-US,290 W AC(0.290 kW),1 PHASE,UL 1741 C 0 MPLIANT REVISIONS: 2O ©ROOFTOP JUNCTION BOX:EZ SO TAR JB-1.2 JUNCTION BOX AQ ---- DO JUNCTION BOX:PVC 4 X4 JUNCTION BOX Q OOPV COMBINER BOX:ENPHASEIQ COMBINER4(XIQ-AM1-240-4) OO SQUARE-D SAFIEYSWBCH 3OA,2P,240VAC,NON-FUSIBLE(DU221RB) Q ---- © Q - O --- O O DRAWN BY: Brendan Fillm o re OQ — PIOTDATE OQ Ja nua ry 5, 2024 8 © DRAWING TITLE: � o T1�R No TEs O9 GROUNDING ELECTRODE SYSTEM SHALLBEIN ACCORDANCE WITH NEC 250.53. Ele c t ric a lO 10 ® 3-Lin e © DRAWING NUMBER 11 ® PV5 AILINTI:RIORCONDULI'MUSTBESCH80PVC.12 O EIEC'TRIG AL INFO RMA'IIO N WIRE SIZE SPEC IFIC ADO N S BLUE RAVEN NOW- L TIIITY ELEC TRIC AL SYSTEM BLUE 2O ® 0 SO © ® 9O 10 1-Pha se,3-Wire,60Hz,120/240V S O LA R MINIMUM CONDUCTORAMPACITY 15.13A AC 15.13A AC 15.13A AC 15.1A AC ----A AC ----A AC ----A AC ----A AC ----A AC ----A AC NEW PV SYSTEM CONDUCTORMATERIAL CU CU CU CU ---- ---- ---- 1403 N 630 E 1-Phase,3-Wire,6011z,120/240V CONDUCTORTYPE THEN/M-IWN-2 T*IN/T1IWN-2 TI4HN/'IHWN-2 'HBN/Tn-IWN-2 ---- --- ---- ---- ---- ---- Ore m,Uta h 84097 AC SYSTEM SIZE 2.9kW AC CONDUCTDRSIZE 12 AWG 10 AWG IO AWG 1 10 AWG ---- DC SYSTEM SIZE 4.1kW DC CONDUCTDRAMPACITY 30A 40A 40A 40A ----:� ----:\ ---;1 ----:\ ----:\ ----A (800)377-4480 PV MODULES AMBIENTTEMPERATUREADJUSTMINTFACTOR 1 1 1 1 ---- ---- ---- ---- ---- ---- Blue Ra Ve nSo la.r.0 om QUANTITY 10 CONDUITFIILADJUSTMENTFACTOR 1 1 1 1 ---- ---- ---- ---- ---- ---- TYPE Silfab So In r SIL,4 10 HC+ ADJ LISTED C0NDUCTORAMPACITY 30A 40A 40A 40A ----A ----A ----A ----A ----_\ ----A WATTAGE 41OWDC WIRE RUN DISTANCE(FT) 66 75 20 5 MICROINVERTERS CALC ULATED VOLTAGE DROP 1 1.34% 1 0.96% 1 0.26% 0.06% 1 0% 0% 1 0% 0% 01, 0% TYPE Enphase IQ8PLUS-72-2-US OLTIPUTC 1.21A AC URRENOMINALVOLIAGENT 240VAC OUTPUTPOWER 20W AC PV C IRC UIT SPEC IFIC ATIO NS PRIMARY STRUC TURE DETAC HED SIRUC TURE a ��//�� �77 NUMBER o f MO DULES PER C IRCUIT CIRCUIT] CIRCUIT2 CIRCUIT3 CIRCUIT T S 4 CIRCUIT5 CIRCU6 CIRCUIT7 CIRCUIT CIRCUIT] CIRCUIT2 CIRCUITS CIRCUU4 CIRCUU5 LO r--� DESIG N C A 1L0 N 10 0 0 0 0 0 0 0 0 0 0 0 0 t) 77���r RATED AC OUIPUTCURRENT(b) 12.1A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA M AND r IPERA�7URES MINIMUM AMPACITY(1,rx 125%) 15.1A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA N OVERCURRINTPROTEC]ION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 4- Q DATA SOURCE ASHRAE We a th e r Sta tio n Da ta U 0"0 STATE Washington COMBINED AC OUIPUTCURRENT(Co) 12.1A O.OA V� CITY Arlington MINIMUMAMPACITY(Co"rx 125%) 15.1A O.OA ,u WEATHERSTATION BOEINGFID KING CO COMBINED PV BREAKER RATING 20AA OAA O HIGH TEMP 2%AVG 29°C EXTREME MINIMUM TEMP -7*C 10 VOLTAGELDROP PV BREAKER BACKFEID CAIACULAIIONS VOLTAGEDROP a NEC 705.12(B)--"120%RULE" WIRE TAG#1 1.34% (BUSBARRATING*120%)-OCPD RATING=AVAILABLEBACKFEED WIRE TAG#2 0.96% O MAIN SERVICE WIRE TAG#3 0.26% O PANEL SUBPANEL l SUBPANEL2 WIRE TAG#4 0.06% U O BUSBARRATING 200A ----A ----A WIRE TAG#5 0% PANEL OCPD RATING 200A ----A ----A WIDE TAG#6 0% U AVAILABLE BACKFEED(120%RULE) 40A ##A ##A TOTAL 2.620000% 1 PV BREAKER RATING 20A 20A 20A *THESE CAILULATIONS ARE ONLY APPLICABLE IF E PV INTERCONNECTION IS A]DAD SIDE BREAKER* O *PV BREAKER MUSTBE RATED LESS THAN 0REQ UAL TO 'c" AVAILABLE BAC IF'EED FO R.C 0 DE C 0 MPIIANC E* z � z � � o V PROJFCTID: 916114 DC SYSTEM SIZE: 4.10 kW DC AC SYSTEM SIZE 2.90 kW AC REVISIONS: A ---- A ---- A ---- DRAWN BY: Brendan Fillm o re PIDTDATE Ja nua ry 5, 2024 DRAWING TITLE: Electrical C a lc u la do n s DRAWING NUMBER PV6 WARNING LABELS FOR PHO TO VO LTAIC SYSTEM Nor- BLUE RAVEN SOLAR UTILITY MEIER MAIN SERVICE PANEL AC DISC O NNEC T 1403 N 630 E Orem,Utah 84097 (800)377-4480 PHOTOVOLTAIC SYSTEBlue Ra ve nSo la r.c om AAC DISCONNECTA RATED AC OUTPUT CURRENT 12.1 A NOMINAL OPERATING AC VOLTAGE 240V n OWARNING ELECTRIC SHOCK HAZARD a TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED PV COMBINER BOX IN THE OPEN POSITION M SOLAR PV SYSTEM EQUIPPED 4- N Q NET METER ; WITH RAPID SHUTDOWN U o RAPID SHUTDOWN SWITCH TURN RAPID SHUTDOWN FOR SOLAR PV SYSTEM SWITCH TO THE PHOTOVOLTAIC SYSTEM .� 'OFF' COMBINER PANEL N �.., - PV SHUTDOWNWN PV S SYSTEM YST AND REDUCE SHOCK HAZARD ARNING x . IN THE ARRAV. U AUTHORIZED PERSONNEL ONLY DO NOT ADD LOADS 4 A NO DC WIRES PRESENT �"� O RAPID SHUTDOWN TEST NOT REQUIRED ;:s FLYi.I{ � bA U O .4 O w r O z � z � � o PROJECTID: A CAUTION 916114 MULTIPLE SOURCES OF POWER DC SYSTEM SIZE: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED 4.10 kW DC SOLAR ARRAY.PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE AC SYSTEM SIZE: OF SIGHT OF UTILITY METER. 2.90 kW AC REVISIONS: A ---- AWARNING DUAL POWER SUPPLY WARN I N 0 ____ SOURCES:ELECT GRID ANDRIC SYSTEM POWER SOURCE RA PV SOLAR ELECTRIC SYSTEM DRAWN BY: OUTPUT CONNECTION DO NOT RELOCATE THIS Bre n d a n Flllm o re OVERCURRENT DEVICE PLOTDATE • *LABELINSTAIJ January 5, 2024 79 IN CASE OF EMERGENCY, NEXT TO PV BREAKER DRAWING WILE: PLEASE CONTACT. BLUE RAVEN SOLAR Warning (800)377-4480 La b e is DRAWING NUMBER LABELS WTIH RO UND C O RNERS ARE ADHESIVE S7TC XER.S PV7 LABELS WHH SQ UARE C O RNERS ARE PLAS-HC ENG RAVED PLAC ARDS • • ELECTRICAL SPECIFICATIONS • • Test Conditions STC NOCT BLUE RAVEN Module Power(Pmax) AR SILF • PRIME S I L FA B • Maximum powerrvoltage(Vpmax) Vp SQL, 38.99 36.24 S O L A Re Maximum power current(Ipmax) A 10.52 8.43 SIL-410 HC+ Open circuit voltage(Voc) V 45.59 42.76 Short circuit current(Isc) A 11.15 5.99 Module efficiency % 20.7% 19.3% Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to+10 Measurement conditions:STC 1000 W/m'•AM 1.5•Temperature 25°C•NOCT 800 W/m'•AM 1.5•Measu rement u ncertai my 5 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by 5%and power by0to+10W. MECHANICAL PROPERTIES/COMPONENTS Module weight 21.3kg 0.2kg 471bs 0.4lbs Dimensions(H x L x D) 1914 mm x 1036 mm x 35 mm 75.3 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)* 5400 Pa rear load/5400 Pa front load 112.8 lb/ft2 rear load/112.8lb/ft2 front load Hail impact resistance o 25 mm at 83 km/h o 1 in at 51.6 mph Cells 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, anti-reflective coating anti-reflective coating Cables and connectors(refer to installation manual) 1350 mm,o 5.7 mm,MC4 from Staubli 53 in,o 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc +0.064 p/o/°C Module product workmanship warranty 25 years** Temperature Coefficient Voc -0.28%/°C Linear power performance guarantee 30years Temperature Coefficient Pmax -0.36%/°C >_97.1%end 1st yyr NOCT( 2°C) 45°C >_91.6%end 12th yr >_85.1%end 25th yr Operating temperature -40/+85°C >_82.6%end 30thyr CERTIFICATIONS SHIPPING SPECS UL 61215-1:2017 Ed.1,UL 61215-2:2017 Ed.1,UL 61730-1:2017 Ed.1,UL 61730-2:2017 Ed.1,CSA C22.2#61730-1:2019 Ed.2,CSA C22.2#61730-2:2019 Ed.2,IEC 61215-1:2016 Modules Per Pallet: 26 or 26(California) Product Ed.1,IEC 61215-2:2016 Ed.1,IEC 61730-1:2016 Ed.2,IEC 61730-2:2016 Ed.2,IEC 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Corrosion),CEC Listing,UL Pallets Per Truck 32 or 30(California) Fire Rating:Type 2 Factory IS09001:2015 Modules Per Truck 832 or 780(California) * A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads. 75.3"[1914mm] r E 12.1"[307mm] 51.2[1300mm] 12.1"[307mm] RELIABLE ENERGY. � SILFAB SOLAR INC. DIRECT FROM THE SOURCEMounting Hole(x4) 800 Cornwall Ave 0.5" Bellingham WA 98225 USA Designed to outperform. ,<�~"°�. [12mm] 7+1360.569.4733 2023 info@silfabsolar.com Dependable, durable, high-performance av L o S I L F A B S O L A R.C OM E 1770 Port Drive solar anels en ineered for North "'"""""'` M E _ Burlington WA98233USA p g m 1.4" 35mm o o f o) ra T+1360.569.4733 American homeowners. ! N a X of 6o 240 Courtneypark Drive East w o co Mississauga ON L5T 2Y3 Canada JILFABS0LAR.Cum 3 N T+1905.255.2501 3r10.5.ml 653.15" F+1905.696.0267 able[135 Length 6l Cable Length f-- o Silfab-SIL-410-HC+-20230726 o(D No reproduction of any kind isallowedwithout // rn`,y- ►/\�/�''��/%]) rainage Hole(x8) permission.Data and information is subject to C C ��w ' w I��j o 2022.iilfab s without r-isar once ed iradem Solar rkof, _ Fraunhofer C H U B B" Sill Silfab solar•isa registeredt tidemark of snfab solar mc. DRAWING NUMBER: In"Is In"" -e 15E *Chubb provides error and omission insurance to Silfab Solar Inc. �2.4"[60mm] 8"[200mm] SS BLUE RAVEN EN PHASE 1�11 IQ8 and IQ8+ Microinverters 1ao3N.Research Way Orem,UT 84097 INPUT DATA r :r 800.377.4480 Commonly used module pairings' w 235-350 235-440 WWW.BLUERAVENSOLAR.COM Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 CONFIDENTIAL-THE INFORMATION half-cell HEREIN CONTAINED SHALL NOT BE MPPT voltage range v 27-37 29-45 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR Operating range v 25-48 25-58 SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Min/max start voltage v 30/48 30/58 RECIPIENTS ORGANIZATION,EXCEPT Max input DC voltage v 50 60 IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, Max DC current2[module lsc] A 15 WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit NAB C E P OUTPUT DATA(AC) 108-60-2-US 108PLUS-72-2-US CERTIFIED Peak output power VA 245 300 PV INSTALLATION Max continuous output power VA 240 290 PROFESSIONAL Nominal(L-L)voltage/range' v 240/211-264 Scott Gurney Max continuous output current A 1.0 1.21 #PV-011719-015866 IQ8 and IQ8+ Microinverters Nominal frequency Hz 60 CONTRACTOR: Easy to install Extended frequency range Hz 50-68 BRS FIELD OPS Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with AC short circuit fault current over 2 385-498-6700 defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors 3 cycles Arms power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication Max units per 20 A(L-L)branch circuit4 16 13 is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components Total harmonic distortion <5% microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple Overvoltage class AC port 111 to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling AC port backfeed current mA 30 energy systems. Power factor setting 1.0 High productivity and reliability Grid-tied power factor(adjustable) 0.85leading-0.85lagging Produce power even when the Peak efficiency % 97.5 97.6 _ Enphase grid is down* CEC weighted efficiency % 97 97 /.5 More than one million cumulative Night-time power consumption mw 60 hours of testing year limited MECHANICAL DATA warranty Class II double-insulated Ambient temperature range -40°C to+60°C(-40°F to+140°F) enclosure Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability Relative humidity range 4%to 100%(condensing) Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV modules DC Connector type MC4 and analysis software. leading limited warranty of up to 25 years. Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm 0.2") Microgrid-forming Weight 1.08 kg(2.38lbs) Complies with the latest Cooling Natural convection-no fans advanced grid support** Approved for wet locations Yes Remote automatic updates for Pollution degree PD3 DRAWING BY: the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with g PP Environ.category/UV exposure rating NEMA Type 6/outdoor cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles PLOT DATE: manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 N0.107.1-01 requirements Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to PROJECT NUMBER: ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other *Only when installed with IQ System Controller 2, manufacturer's instructions. names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility IQ8 and IQ8PIus supports split phase,240V (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ---- SS '1� Data Sheet Enphase Q Cable Accessories BLUE RAVEN Enphase QCable Accessories SOLAR REGION:Americas CONDUCTOR SPECIFICATIONS Certification UL3003(raw cable),UL9703(cable ass emblies),DGcable Flame test rating FT4 Compliance RoHS,OILRES I,CE,UV Resistant,combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Enphase The Enphase Q CableTMand accessories are part of Disconnecting means The AC and DCbulkhead connectors have been evaluated and approved byULforuse as the load-break the latest generation Enphase IQSystemTMThese disconnect required by NEC690. QCable Accessories accessories provide Simplicity reliability,and faster Q CABLE TYPES/ORDERING OPTIONS installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing PVModule Orientation Connector Count per Box Q-12-10-240 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Q-12-20-200 12 AWG/277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 ENPHAS E Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Field-wireable connector(male) Q-CONN-10M Make connections from any open connector • Two-wire,double-insulated Enphase Q Cable Field-wireable connector(female) Q-CONN-IOF Make connections from any QCable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Enphase cable • New cable numbering and plug and play Disconnect tool Q-DISC-10 Disconnect tool forQCableconnectors,DCconnectors,andACmodulemount connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEALr10 One needed to cover each unused connector on the cabling wire management Link connectors eliminate cable waste Terminator Q-TERM-10 Terminator cap forunused cable ends • Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PVmodule using MC4 connectors to IQmicros with EN4(TEPV4-S SOLARLOK). 150mm/5.9"to MC4. Enphase EN4 non-terminated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non-terminated cable.150mm/5.9" Field-Wireable Connectors Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TEPV4-S SOLARLOK)to MC4.Use with split cell modules orPVmodules with short DC cable.600mm/23.6" • Eas ily connect Q cables on the roofwithout Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptor to MC4(max voltage 100 VDC) complex wiring Replacement DC Adaptor(UTX) Q-DCC-S DC adaptor toUTX(max voltage l00VDC) • Make connections from any open connector and center feed any section of cable within 1.Qualified per UL subject 9703. branch limits • Available in male and female connector types TERMINATOR SEALING CAPS Terminatorcap forunused cable Sealing caps for unused aggregator ends,sold in packs often and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEALr10) DISCONNECT TOOL CABLE CLIP Plan to use at least one per Used to fasten cabling to the racking installation,s old in packs often orto secure looped cabling,sold in (Q-DISC-10) 40 46 packs ofone hundred(Q-CLIP-100) To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ L E N P H A S E® Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. ENPHASG To learn more about Enphase offerings,visit enphase.com 2020-06-26 DRAWING NUMBER_* SS IQ Combiner 4/4C BLUE RAVEN Enphase Networking MODEL NUMBER 1403 N.Research Way Orem,UT 84097 IQ Cambiner 4 X40-AM I.240.4 800.377.4480 X2-10-AM1-240.4(IEEE 154y:20111j, WWW.BLUERAVENSOLAR.COM 10 Combiner 4C n;ccrnbu•.or 4,cur;h d::ratrway pnrtrn urrw:C.�rr,lrn:,tr 7rntcd tevorwt vadir PY; CONFIDENTIAL-THE INFORMATION Q Combiner 4/4 C X40•AMt•240 4C and consumption monitoring 2 5%) Includes Mobile Connect cellular modem(CELLMODEM-Ml-06-SP-05),a pkxg-and-play The IQ Combiner 4/4C with IQ Gateway and ✓Idustrial-grade cell modern for systems up to60mrcrourxrtem(Available in this,KCansda,Max",PrrerMRuco,andthe HEREIN CONTAINED IT OF NOT BE XI 1Q AMt 240-4C(IEEE 15412018) USED FOR THE BENEFIT OF ANYONE US Virgin talents,where Ilene is adequate cellular serixe in the Inatallaton area)Includes a elver solar shield to match the EXCEPT BLUE RAVEN SOLAR NOR integrated LTE-M 1 cell modem(included IQ Battery and 10 System Controller and to deflect heat SHALL IT BE DISCLOSED IN WHOLE OR only with IQ Combiner 4C)consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT Supported mrcroinverters 106.107,and 108(Do not mix IG617 Micrtlimarters with IQtI) IN CONNECTION WITH THE SALE AND interconnection equipment into a single communications Kit USE OF THE RESPECTIVE EQUIPMENT, enclosure- It streamlines IQ Microinverters and COMMS CELLMODEM MI-06 -Includes COMMS-KIT-01 and CELLMODEM-MII-06-SP-05 with 5-year Spmi data plan WITHOUT THE WRITTEN PERMISSION CELLMODEM Ml 06-SP 05 40 based LTE-Mll cellular micidem with S year Sprint data plan OF BLUE RAVEN SOLAR LLC. storage installations by providing a consistent, CELLMODEM M1 06 AT 05 4G based LTEMI cellular modem with 5-yeat AT&T data plan Ckcwt ereatrats Supports Eaton BR210•BR21 S.1111111220.BR230,BR240.BR250.and BR260 circuit breakers pre-wired solution for residential applications ORK•IOA•2.240V Circuit breaker.2pole.10A,Eaton OR210 NABCEP ORK•ISA•2.240V Circuit breaker,2 Pole,I5A.Eaton BR215 It offers up to four 2-pole input circuits and 5RK-20A•2P-240V Circuit breaker,2 pulp,20A.Eaton DR220 BRK•15A-2P-24OV-B Circuit breaker.2 pole.1 SA.Eaton BR2158 with told down lut support [CERTIFIED] Eaton BR series bulbar assembly. BRK-20A•211-24OV-e Circuit breaker,2 pole,20A.Eaton BR2209 with hold down kit support XA-SOLARSHIELD ES Replacement solar shield lot IQ Combiner 4/4C PV INSTALLATION XA-PLUG-120.3 Accessory receptacle for Power line Career In 10 Combiner 414C(requirad for EPLC-Ot) PROFESSIONAL X-10 NA-HD-125A Hold down kit for Eaton crane breaker with screws Scott Gurney #PV-011719-015866 consumption monitoring CT A paw of 200A split tort current transformers Smart (CT•200.9PUT/CT-20D-CL AMP) ELECTRICAL SPECIFICATIONS CONTRACTOR: • Includes IQ Gateway lot communication and control BRS FIELD OPS • Includes Mobile Connect cellular modem Rotting eonarwarsduty 385-498-6700 (CELLMODEM M1 06-SP-05),included only with System voltage 1201740VAC,60 Hz IQ Combiner 4C Eaton 8R series busby toting 12SA • Includes solar shield to match Enphase 10 Battery Max conlim e,turtrw rating 6SA aesthetics and deflect heat Mo nn+.an,toting few from PY/LtoroW) 64A • Supports Wi-Fi,Ethernet,or cellular connectivity Max fuse/circurl rating(output) 90A • Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2.pole Eaton BR series Disttlbuted Generation(DO)breaker*only(rot Included) L, • Provides production metering and consumption Ma. total branch circuit breaker rating(input) 80A of distributed genetanone95A with IQ Gateway breaker included I. monitoring 10 Gatevny breaker 1 DA or 1$A rating GE/SlemarwEata n Included production Inetering CT 200A solid core pre-tnstalled and weed to IQ Gateway Simple MECHANICAL DATA X-10•AM1-240.4C Mounts on single stud with centered brackets Dimensions(WxflxD) 37 5 cm■49 5 cm a 16.E c m(14 751n s 19 5 in x 6 631n) Height Is 53 5 cm(21,06 urn)with mounting brackets • c2.10-AM1-2404C(IEEE 154).2014) Supports bottom,back and side conduit entry weight 7 5 tg 06 5Its) Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range J11eC to.46'C(40rif to t15K) plug-in breakers(not Included) Cooling Natural con ectron,plus heat thkld • 80A total PV or storage branch circuits Enclosure environmental rating Outdoor.NRTitertl4ed.NEMA type 31L potycerbonme construction Wife sites 20A to 50A breaker inputs 14 to 4 AWG coppet conductors Reliable 60A breaker branch input 4 to 110 AWG copper conductors Main lug combined output 10 to 2/O AWG copper conductors • Neutral srul ground.14 to 110 copper conductors • Durable NRTL-Certified NEMA type 3R enclosure Always follow local code requirements for conductor sung • Five-year limited warranty Attitude Up to 3.000 metes(9,1142 feet) • Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS Included for both the IQ Combiner SKU•s Integrated cur-FI IEEE B02 llb/g/n X-10-AM1-240-4 ' UL listed CedL,ar CELLMODEM•Mt•06-SP-OS.CELLM ODE M•M1.06•AT•05(4G based LTE-k/t cellular modern) Natethat on MobaeConnect • X2-IQ-AM1.240.4 and X2•10•AM1-240.4C comply with cellular modern lstequnred for all EnphaseEnergySyaemrnstsYshona. X2-)Q-AM1.240.4(IEEE 1547 2018) IEEE IS47 2018 'UL 1741-SB.3 Ed. ( ) Etnrnnet Optional,IEEE 802-1 COME(of Ca16)UTP Ethernet able(not wtcluded) COMPLIANCE O CompYrrce,lit comrirnet E Rule 21 01 1741-SA) I U� EEE 1547201a•UL 1741•SB.J•'Ed(X2•10 AMt-240.4 and X2-I0-AM11-240-4C) CANICSA C22.2 No.1071.Title 47 CFFk Part 15.Class B.ICES 003 LISTED Production matter"ANSI C1220 accuracy clew 0 5(PV production) EN P H A S E Consumption meaning:accuracy class 2 5 To learn more about Enphase offerings,visit en hase.com �/ omossom10Gateway UL 60601.liCAW-SA22 2 No 61010.1 P 9 P SHEET NAME: 'Q C-4.4C-DS-0103 EN-US-12.29.2022 O 2022 Enphase Energy.M Va reserved Enphosr,fhe Enphase logo,IQ Combiner 4/4C.and other names are tradarrwks or ErsphaseEihagil,WData-boa toehorw 10-C4-4C•DS-0103-EN•US-12.29.2022 SPEC SHEETS REVISION: PAGE NUMBER: 0 SS BLUE RAVEN Data Sheet Enphase Networking 1 7 L Elly�llaS e 1 L11V0V 1403 N.Research Way Y Q > Orem,UT 84097 800.377.4480 MODEL NUMBERS WWW.BLUERAVENSOLAR.COM Enphase IQEnvoy"m Enphase IQ Envoy communications gateway with integrated revenue grade PV CONFIDENTIAL-THE INFORMATION ENV-IQ-AMl-240 production HEREIN CONTAINED SHALL NOT BE metering(ANSI C12.20+/-0.5°/u)and optional consumption monitoring(+/-2.5%). USED FOR THE BENEFIT OF ANYONE Includes EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR Enphas e IQ Envoy The Enphas e IQ Envoy'r"tommunications gateway one 200Acontinuous rated production CT(current transformer). IN PART TO OTHERS OUTSIDE delivers Solar production and energy COriSUmptlOn ACCES DRIES (Order Seperately) RECIPIENTS ORGANIZATION,EXCEPTIN CONNECTION WITH THE SALE AND Enphase Mobile ConnectTM Plug and play industrial grade cellular modem with data plan for systems up to 60 USE OF THE RESPECTIVE EQUIPMENT, data to Enphase EnlightenTMmonitoring and analysis CELLMODEM-Ml(4Gbased LTE-M/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin WITHOUT THE WRITTEN PERMISSION software for comprehensive,remote maintenance and CELLMODEM-MI-B(4G-based LTE-Ml/5-year data plan) Islands,where there is adequate cellular service in the installation area.) OF BLUE RAVEN SOLAR LLC. Consumption Monitoring CT Split-core consumption CTs enable whole home metering. management of the Enphase IQ System. CT-zoo-SPLIT Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase EnchargeTMstorage NABCE P COMMS-KIT-0I and Enphas e Enp owe frl,%mart switch.Includes USB cable for connection to IQ C E RT I F I E D With integrated revenue grade production metering EnvoyorEnphase IQ CombinerTMand allows wireless communication with Encharge and Enpower. and optional consumption monitoring,Envoy IQ is the POWER REQUIREMENTS PV INSTALLATION PROFESSIONAL platform for total energy management and integrates Power requirements 120/240 VAC split-phase. Scott Gurney Max 20 Aovercurrent protection required. #PV-011719-015866 with the Enphase EnsembleTInd the Enphase IQ Typic al Power Cons umption 5W BatteryTM CONTRACTOR:CAPACITY BRS FIELD OPS Number ofmicroinverters polled Up to 600 385-498-6700 MECHANICAL DATA Dimensions(WxHxD) 21.3 x 12.6 x4.5 cm(8.4"x5"x 1.8') Smart Weight 17.6 oz(498 g) • Enables web-based monitoring Ambient temperature range -400 to 650 C(400 to 149°F) and control 40'to 46'C(-40°to 115'F)if installed in an enclosure Bidirectional communications for Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure. • remote upgrades Altitude To 2000 meters(6,560 feet) •Supports power export limiting and Production CT -Limited to 200Aofcontinuous current/250AOCPD—72kW AC zeroexport applications -Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) -UL2808 certified for revenue grade metering Consumption CT -For electrical services to 250Awith parallelruns up to 500A -Internal aperture measures 0.84"x 0.96"(21.33mm x 24.38mm)to support Simple 3/0 THWN conductor Easy system configuration using -UL2808 certified,for use at service entrance for services up to 250Vac Enphase histallerToolkitT'"mobile app INTERNET CONNECTION OPTIONS • Flexible networking with Wi-Fi, Integrated Wi-Fi 802.1lb/g/n Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLMODEM-Ml(4G)or CELLMODEM-MI-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable COMPLIANCE • Compliance UL61010-1 Designed for installation indoors CAN/CSAC22.2 No.61010-1 or outdoors 47 CFR,Part 15,Class B,ICES 003 DRAWING BY: • Five-year warranty IEC/EN61010-1:2010, EN50065-1,EN610004-5,EN61000-6-1,EN61000-6-2 Metering:ANSIC12.20 accuracy class 0.5(PVproductiononly) PLOT DATE: PROJECT NUMBER: ENPHASE. To learn more about Enphas eofferings,visit enphase.com ENPHASE SHEET NAME To learn more about Enphase offerings,visit enphase.com �/ u SPEC C ©2021 Enphase Energy.Allrights reserved.Enphase,the Enphase logo,IQEnvoy,and othertrademarks or service names are the trade- Sr EC SHEET marks of Enphase Energy,Inc.Data subject to change.06-30-2021 REVISION: PAGE NUMBER: ---- SS BLUE RAVEN 1403 N.Research Way Orem,UT 84097 WIRING DIAGRAMS 800.377.4480 W W W.BLU ERAVENSOLAR.COM 6.75 FUSIBLE NOT FUSIBLE CONFIDENTIAL-THE INFORMATION [172] HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE ZF3 O O EXCEPT BLUE RAVEN SOLAR NOR I I SHALL IT BE DISCLOSED IN WHOLE OR [7] IN PART TO OTHERS OUTSIDE 3 HOLES I/ I/ RECIPIENTS ORGANIZATION,EXCEPT /� C f 7 IN CONNECTION WITH THE SALE AND b( b( USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. S N 9.00 6.00 [229] NABCEP 29 [1521 ° �L Q11 QJ CERTIFIED ABC B D / / / KNOCKOUTS of to OI PV INSTALLATION PROFESSIONAL Scott Gurney A o #PV-011719-015866 4.50 KNOCKOUTS 4.60 TERMINAL LUGS$ CONTRACTOR: [1141 [117] BRS FIELD OPS AMPERES MAX. WIRE MIN. WIRE TYPE 385-498-6700 # 6 AWG # 12 AWG AL 7.50 30 # 6 AWG # 14 AWG I CU [191]� KNOCKOUTS SYMBOL A B C D A,B,C O CONDUIT SIZE .50 .75 1 1.25 KNOCKOUTS -0 MAO NEMA TYPE 3R ILLUSTRATED DUAL DIMENSIONS: INCHES MILLIMETERS A,B,C,D KNOCKOUTS HORSEPOWER RATINGS CATALOG VOTAGE WIRING 120VAC 240VAC NUMBER RATINGS DIAG. STD. MAX. STD. MAX. 10 10 10 30 10 30 D211NRB60 240VAC A 1/2 2 1 1/2 — 3 — NOTES: D221NRB 240VAC A — — 1 1/2 3* 3 7 1/2* FINISH — GRAY BAKED ENAMEL ELECTRODEPOSITIED OVER CLEANED PHOSPHATIZED STEEL. D321NRB 240VAC B — — 1 1/2 3 3 7 1/2 UL LISTED — FILE E-2875 DRAWING BY: ALL NEUTRALS — INSULATED GROUNDABLE DU221RB 240VAC C — — — — 3 — SUITABLE FOR USE AS SERVICE EQUIPMENT DU321RB 240VAC D — — — — 3 7 1/2 TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT—ON HUB. SHORT CIRCUIT CURRENT RATINGS: • 10,000 AMPERES. PLOT DATE: 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES. GENERAL DUTY SAFETY SWITCHES ' 100,000 AMPERES WITH CLASS R FUSES.* agolm FOR CORNER GROUNDED DELTA SYSTEMS. VISIBLE BLADE TYPE PLUG FUSES 30 AMPERE by Schneider Electric PROJECT NUMBER: ■$ LUGS SUITABLE FOR 60'C OR 75' CONDUCTORS. ENCLOSURE — NEMA TYPE 3R RAINPROOF DWc#N0. 1852 FEBRUARY 2014 REF DWG #1852 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ---- SS J B- 1 .2 EZf SOLAR PHONE: 385-202-4150 EZf SOLAR Specification Sheet making solarslmpio, WWW.EZSOLARPRODUCTS.COM BLUE RAVEN making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs 1403 N.Research Way Orem,UT 84097 A. System Specifications and Ratings ITEM NO. PART NUMBER DESCRIPTION OTY ESC DWG.NO REV 800.377.4480 POLYCARBONATE WWW.BLUERAVENSOLAR.COM • Maximum Voltage: 1,000 Volts 1 JB-12 BODY 1 CONFIDENTIAL-THE INFORMATION WITH UV INHIBITORS WEIGHT:1.45 LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE • Maximum Current: 80 Amps USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN JB 1.2 LID POLYCARBONATE 1 SHALL IT BE DISCLOSED INWHOLE NOR Allowable Wire: 14 AWG —6 AWG 2 p WITH UV INHIBITORS TORQUE SPECIFICATION: 15-20 LBS IN PART TO OTHERS OUTSIDE • RECIPIENTS ORGANIZATION,EXCEPT Spacing: Please maintain a spacing of at least '/2" between uninsulated live arts and fittings for p g p g IN CONNECTION WITH THE SALE AND conduit, armored cable, and uninsulated live parts of opposite polarity. #10 X 1-114"PHILLIPS UL STANDARD 1741, USE OF THE RESPECTIVE EQUIPMENT, THE WRITTENSSION Enclosure Rating: Type 3R 3 PAN HEAD SCREW 6 CERTIFICATION: NEMA 3R WIT OFUBLUE RAVEN SOLAR PERMIC 9� Yp . ' • Roof Slope Range: 2.5— 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS NABCEP • Max Side Wall Fitting Size: 1" PAN HEAD SCREW • Max Floor Pass-Through Fitting Size: 1" 1 CERTIFIED • Ambient Operating Conditions: (-35°C) - (+75°C) PV INSTALLATION • Compliance: PROFoESSIONAL tt Gurney - J13-12 UL1741 #PV-011719-015866 -Approved wire connectors: must conform to UL1741 CONTRACTOR: • System Marking: Interek Symbol and File #5019942 BRS FIELD OPS • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion 385-498-6700 between components, components that are found to be affected are to be replaced immediately. Table 1:Typical Wire Size,Torque Loads and Ratings Torque 1 Conductor 2 ConductorType NM htch Lbs Voltage Current - ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.".7 6.2-8.8S 600V 30 amp ABB ZS30 terminal block 6.24 awg 12-20 aw Sol/Str 1.0-1.6 9.85-14.16 600V 40 am ABB ZS16 terminal bock 4.24 awl, 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 am ABB M5/8 terminal block 8.22 awg Sol/Str .08-1 &FIS 600V 50 amp 127 1.01 in ] [27 0.0 n Ideal452 Red WING-NUT Wire 1 1.011n 10.8&n 8-Is awg Sol/Str Self Torque SelfConnector Torque 600V Ideal 451 Yellow WING-NUT SOLAR Wire Connector 1018awg Sal/Str Self Torque Sdiiorque 600V Ideal,In-Sure Push4n 10.14 awg Sol/Str Self Torque W Torque 600V Connector Part#39 JB-1.2 WAGO,2204-1201 10-20 awg 16 24 awg Sol/Str Self Torque WfTorquel 600V I 30 arnp WAGO,221-612 10-20 awg 10-24 awg Sol/Str Self Torque Sell Torque 600V 30 amp i DottieDRC7S 6-12 awg Sol/Str Snap-In Srw4n ! ESP NG-53 4-6 awg Sol/stir 4S 2000V 10.14 awg Sol/sir 35 ESP NG-717 4,6 XWg Sol/Str 45 2000V - 10,14aft Sol/Str 35 DRAWING BY: 4-6awl Sol/Str 45 Brumau a-s,3 z000v Io 14 awg Sol/Str 3s (183.06mm] 72.53mm 7.21 in 2.86in PLOT DATE: Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) [265.18mm] Wire size,AWG or Wires per terminal(pole) 10.44in 1 2 3 4 or More PROJECT NUMBER: kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not specified - - 8 (8.4) 38.1 (1-1/2) SHEET NAME: 6 (13.3) 50.8 (2) SPEC SHEET REVISION: PAGE NUMBER: EZtSOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM PROPRIETARYAND CONFIDENTIAL:THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTYOF EZ SOLAR. ———— SS ANY REPRODUCTION IN PARTOR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. Rigid Nonmetallic Conduit BLUE RAVEN S U� r�011' 1403 N.Research Way 097 Molded Nonmetallic Junction Boxes Except ere noted Orem,77 8480 LISTED by t E42728 VIEW SHOWN LESS WWW.BLUERAVENSOLAR.COM 6P Rated COVER FOR CLARITY 3.)0 CONFIDENTIAL-THE INFORMATION (941 0.20 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE It's another first from Carlon°-the first nonmetallic (5 I EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR junction boxes UL Listed with a NEMA 6P rating per IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT Section 314.29,Exception of the National Electrical Code. A IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, Manufactured from PVC or PPO thermoplastic molding 3.70 WITHOUT THE WRITTEN PERMISSION compound and featuring foam-in-place gasketed lids --- (9 41 4 50 OF BLUE RAVEN SOLAR LLC. attached with stainless steel screws,these rugged 1541 1 12,71 enclosures offer all the corrosion resistance and physical NABCEP properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor CERTIFIED _ use,primarily to provide a degree of protection against PV INSTALLATION contact with enclosed equipment,falling dirt,hose- PROFESSIONAL directed water,entry of water during prolonged - B Scott Gurney #PV-011719-015866 submersion at a limited depth,and external ice f CONTRACTOR: formation. BRS FIELD OPS TD� 385-498-6700 w •All Carlon Junction Boxes � T are UL Listed and maintain 0 0— o AT a minimum of a NEMA Type 4/4x Rating. COI D. � • Parts numbers with an H 0 l3 0 C asterisk(*)are UL Listed and SIZE A e c maintain a NEMA Type 6P E989NNJ 2.00 4.63 5.13 E989NNJB I50,8) 1111,6) (130.2) A CO o Rating an Type 4I4X Rating. E989NNJ-CAR A E989NNJCL _ TB E98ONNJL 0 O 0 AB (4Y4%2) E989NNR 6.00 5.00 5.50 E989NNR-CAR 1152.1) 1127,0) 1139,1, (4%4%6) 15 j Size in Std. Material Std. 13,81 Inches Ctn. Min Min. Min. Min. Ta Tc Thermo- Ctn. Part No. H x W x D Qty. AT All B C Typical PVC plastic Wt.(Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 311/16 35/8 N/A 2 .160 .155 X 3 E987N-CAR* 4x4x4 5 311/16 31/2 N/A 4 .160 .155 X 4 NOTES: ATERIAL: PVC SECTION 14-14 tE989NNR-CAR* 4x4x6 4 311/16 33/8 N/A 6 .160 .200 X 5 2. NEMA TYPES: 4/4X, 6P C SCALE 0.500 E989PP1-CAR* 5 x 5 x 2 4 411/16 41/2 N/A 2 .110 .150 X 3 E987R-CAR* 6 x 6 x 4 2 6 55/8 N/A 4 .190 .190 X 3 DRAWING BY: E989RRR-UPC* 6 x 6 x 6 8 55/8 53/8 N/A 6 .160 .150 X 14 GENERAL NOTES E989N-CAR 8 x 8 x 4 1 8 8 N/A 4 .185 .190 X 2 1. ALL DIMENSIONS ARE FOR "James 1261210ft REFERENCE ONLY. ■Iriv,Inb.com PLOT DATE: E989SSX-UPC 8 x 8 x 7 2 721/32 75/16 N/A 7 .160 .150 X 6 2. DIMENSIONS I N BRACKETS [ 1 E989UUN 12 x 12 x 4 3 115/8 111/2 111/8 4 .160 .150 x 12 ARE IN METRIC UNITS, DESCRIPTION: MOLDED NON-METALLIC ENCLOSURE REYBIONS E989R-UPC 12 x 12 x 6 2 1115/16 117/8 117/16 6 .265 .185 X 10 F SEE ERN 2016195 PROJECT NUMBER: FOR APPROVAL SIGNATURES ORIGINAL PROJECT NO / I ERN NO ) 1 SHEET NO: I REV. NO: I DRAWING NO: PROJECTS NO: 5AM000006 / ( ( 2 OF 2 F WSD-AC01977 THIS DRAWING IS INTENDED FOR DESCRIPTIVE PURPOSES ONLY. AND THE RIGHT IS RESERVED TO DEVIATE FROM ANY OF THE DETAILS SHOWN HEREON, SHEET NAME: 180 www.carIon.com Copyright Thomas 6 Betts - Proprietary, All Rights Reserved Gross Automation(877)268-3700 •www.carionsales.com •sales@grossautomation.com SPEC SHEET REVISION: PAGE NUMBER: ---- SS i1� BLUE RAVEN "Stay Connected" with H E=YC 0 soLax r , r tr Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Ultimate in Liquid Tight Strain Relief Protection PRODUCT! GLAND PART NO. DESCRIPTION PART DIMENSIONS •Two new cordgrips now accommodate CONFIGURATION Q/sF A B C D E the Enphase Q Cable—M3231 GCZ Conductors or Clearance Max.O.A. Thread Wrenching Nut (1/2—NPT)and M3234GDA-SM Type Size No. Black 911�, Hole Dia. Length Length Thickness Flat Size (3/4""NPT). mm. in. Imm. in.Imm. in.1mm in. mm. in.1mm. Oval Gland •The 1/2-version provides liquid tight Q Cable I6j x V, 1 JM3231GCZ I LTCG 1/2 6.1x9.7MM IQ/SP .875I22,2I1.70I43,2I.61 115,51.21 15,3I .98I24,9 entry for one Enphase — Break-Thru Skinned Over Gland .24 x.38""(6,1 x 9,7 mm). QCables 6,1 x9,7 2 SMCG 3/42-6.1x9.7MM The 3/4-version provides liquid tight plus 3 3 1 M3234GDA-SM 1-3.3MM /sr1.040 26,4 2.00 50,8 .62 15,7 .25 6,4�11.30 33,0 entry for up to two Enphase Q Cables— Ground .24 x.38"(6,1 x 9,7 mm)and an Metal Locknuts INCLUDED. B additional .130" (3,3 mm)dia.hole for C a#8 solid grounding cable. 'I ° �A� •The 3/4-version utilizes our Skinned- over technology so any unused holes will retain a liquid tight seal. i •Rated for use with DG Cable. � SUGGESTED CLEARANCE HOLE SEALING NUT INTEGRAL FOR NONTHREADED MOUNTING SEALING RING Material Nylon 6/6 with TPE Sealing Gland Certifications © Listed under Underwriters'Laboratories File E504900 SP CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40oF(-40oC)to 239GF(115°C) Dynamic-4°F(-20oC)to 212°F(1 DOT) IP Rating IP 68 ALL NEW Heyco° Helios® UVX Clip - Blind Mount �oDucT! PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL •The jersey pine tree mounting style RANGE HOLE DIA. HEIGHT installs easily with superior holding Minimum Maximum 1-2 Wires A C power in. mm in. mm. in. mm. in.I mm. .UVX nylon protects from corrosion due 1-2 Wires to outdoor exposure. (5,8 mm)-.32(8,0 mm) •S6520 Helios UVX Clip 100 Pack028 0,7 .250 6,4 �.23 each cable S6560 Helios UVX Clip Bulk 260 6,6 .96 �24,4 Installs into.260""(6,6 mm)mounting hole. •Holds up to 2 cables between .230- .315-(5,8-8,0 mm)each. •Cables install with fingertip pressure.C . A •Molded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our -T Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F(-20oC)to 185°F(85°C) 1-800-526-4182•732-286-1800(NJ)•FAX:732-244-8843•www.heyco.com 1-4b DE G NUtBFP SS Nor- BLUE RAVEN soLax SFM INFINITY — ::D U N I RAr. • BETTER SOLAR STARTS HERE �a U D03"" SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PARTNAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY ff TRIMRAIL Structural front trim provides aesthetic and aligns modules. Make two installs per day your new standard.SFM INFINITY has fewer roof attachments,one tool installation,and pre-assembled components TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. to get you off the roof 40%faster. i TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. � HOMEOWNERS SFM INFINITY 15 Attachments 87% MODULE CLIPS Secure modules to TRIMRAIL. BETTER AESTHETICS MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. - Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. k with integrated front trim,trim end caps,dark components,and60 ATTACHED SPLICE also available. recessed hardware. lft� SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density With fewer SKUs and compact components,SFM INFINITY is easier to without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES attachments required by rail. stock,easier to transport,and easier to lift to the roof.Plus,make more PARTNAME DESCRIPTION efficient use of your vehicle fleet. TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules O N/S BONDING CLAMP Electrically bonds rows of modules 00404 • • SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. DRAWIlVG NUMBIR SS SUN i BLUE RAVEN % -a I SYSTEM BONDING & GROUNDING 1 19 SOLAR SFRAME I� ■ F M MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ 911 , 1 ' ILAJI I I-Xi In E W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. I I Star Washer is WEEBLUG Single Use Only Single Use Only Alternate method N-S BONDING PATH: TERNINALTORQUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMNALTORQUE, TERMNALTORQUE bonding pins. (refer also to alternate method) 4-6 AWG 35in-lbs Install Conductor and Install Conductor and 8 AWG 25 in-lbs torque to the following: torque to the following: 10-14 AWG 20 in-lbs 4-14 AWG 35in-lbs 6-14 AWG 7ft-lbs LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7) `-�- • 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware • Torque = 5 ft-lb 0 Torque = 75 in-lb 0 Torque = 10 ft-lb Alternate method • AWG 4-14-Solid or Stranded 0 AWG 4-14-Solid or Stranded 9 AWG 6-14-Solid or Stranded TRIN1RAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUNIINUMCONTACTTO PREVENT CORROSION Trimrail to module bonding is accomplished with System bonding is accomplished through modules. System grounding accomplished by attaching bonding clamp with integral bonding pin and a ground lug to any module at a location on the module specified by the module manufacturer. bonding T-bolt. (refer also to alternate method) DRAWING NUMBER SS Nor- SUN BLUE RAVEN 1 Z 0 SOLAR ■ ■ FRAME so_____ -__S-FM -MICRORAILTM INSTALLATION GUIDE ; PA G-E SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME M ICRORAI L11 components shall B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules. Class A, B & C system level fire Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required U12 7 0 3 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF / 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa c) Down-Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF / 8000 Pa b) Upward Pressure - 75 PSF / 3500 Pa c) Down-Slope Load - 32.4 PSF / 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less DRAWING NUMBER: SS Nor- SUN BLUE RAVEN 2 2 SOLAR MbI6 FRAME ■ ■_____ -__S-FM -MICRORAILTM INSTALLATION PAGE -GUIDE- 'I- Manufacture Module Model/ Series Manufacture Module Model/ Series Manufacture Module Model/ Series Aleo P-Series Eco Solargy Orion 1000&Apollo 1000 L&m- N2T-A4 ET Solar ET-M672 BHxxxTW LGxxx(A1 C/E 1 C/E 1 K/N 1 C/N 1 K/N 2T/N 2 W/ DNA-120-(BF/MF)26 Aptos Freedom Forever FF-MP-131313-370 01C/01K/S1C/S2W)-A5 DNA-144-(BF/MF)26 FreeVolt Mono PERC L(3xxxN2T-B5 LGxxxN1 K B6 CHSM6612P,CHSM6612P/HV,CHSM6612M, GCL GCL P6&GC1,M6 Series LGxxx(A1C/M1C/M1K/N1C/N1K/01C/01K/ Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), Hansol TD-AN3,TD-AN4, LG Electronics CAC/OAK)-A6 CHSM72M-HC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W)-E6 Auxin AXN6M610T,AXN6P610T 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 AXN6M612T&AXN6P612T Heliene 144HC M6 Monofacial/Bifacial Series, U3xxxN2T--J5 AXlblackpremium 60(35mm), 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 AXlpower 60(35mm), HT Solar HT60-156(M) (NDV) (-F), LGxxx(N1C/01C/01K)-N5 Axitec AXlpower 72 (40mm), HT 72-156(M/P) LGxxx(N1C/N1K/N2W/01C/01K)-V5 AXlpremium 60(35mm), Hyundai KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM AXlpremium 72 (40mm). HiA-SxxxHG LR4-72(HIH/HPH)-xxxM Boviet BVM6610, ITEK iT iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30mm) BVM6612 Japan Solar JPS-60&JPS-72 Series LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) BYD P6K&MIHK36 Series LONGi LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) CS1(H/K/U/1� MS CS3(K/L/U),CS3K-MB-AG,CS3K-(MS/P) xxx,JAP6(k)-72-xxx/4BB,JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM Canadian Solar CS3N-MS,CS3U-MB-AG,CS3U-(MS/P),CS3W JAP6(k)-60-xxx/4BB,JAP60SYY-xxx/ZZ, (35mm) CS5A-M,CS6(K/U),CS6K-(M/P),CS6K-MS JASolar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) CS6P-(M/P),CS6U-(M/P),CS6V-M,CS6X-P JAM6(k)-60-xxx/ZZ,JAM60SYY-xxx/ZZ. Mission Solar Energy NEE Series i.YY:01,02,03,09,10 Centrosolar America GSeries&E-Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi MJE&MLE Series CT2xxMxx-01,CT2xxPxx-01, JKM&JKMS Series Neo Solar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, CTxxxMxx-04,CTxxxHC11-04 Jinko Eagle JKMxxxM JKMxxxM-72HL-V Dehui DH-60M Kyocera KU Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information DRAWINGNUMBEIt SS Nor- SUN BLUE RAVEN 2 3 SOLAR MbI6 FRAME on_____ -__S-FM -MICRORAILTM INSTALLATION GUIDE ; PAGE Manufacture Module Model/ Series Manufacture Module Model/ Series Manufacture Module Model/ Series EVPVxxx(H/K/PK), TwinPeak Series Suniva MV Series & Optimus Series VBHNxxxSA15 & SA16, TwinPeak 2 Series A-Series A400-BLK,SPR-MAX3-XXX-R, SunPower VBHNxxxSA17 & SA18, REC Solar(cont.) TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M)72(XV) Suntech STP,STPXXXS-B60/Wnhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38mm) TP572,TP596,TP654,TP660, VBHNxxxZA01,VBHNxxxZA02, TP4(Black) Talesun TP672,Hipor M,Smart VBHNxxxZA03,VBHNxxxZA04 Renesola Vitrus2 Series & 156 Series SC,SC B,SC B1,SC B2 Peimar SGxxxM FB/BF Risen RSM72-6 MDG M ,RSM60-6 Tesla ( ) ( )( ) TxxxH,TxxxS Phono Solar PS-60,PS-72 SEG Solar SEG-xxx-BMD-HV PA05,PD05,DD05,DE06,DD06,PE06, Prism Solar P72 Series SEG-xxx-BMD-TB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy SN72 & SN60 Series(40mm) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim SECT-6 &SRP-6 Series UP-MxxxP(-B), PEAK DUO BLK-G6+ Upsolar Q• Sharp NLT-SA&NLT-SC Series � U P-Mxxx M(-B) Q.PEAK DUO BLK-G6+/TS SLA, SLG,BC Series & SlLxxx(BL/NL/NT/HL/ D7MxxxH7A,D7(M/K)xxxH8A BLK -G8 OYEAK DUO + Silfab ( ) ( ) M L/B K/N X/N U/H C) United Renewable Energy FAKxxx(C86/E8G),FAMxxxE7G-BB O.Cells Q.PEAK DUO L-G8.3/BFF Solarever USA SE-166*83-xxxM-120N (URE) FAMxxxE8G(-BB) Q.PEAK DUO(BLK) ML-G9(+) FBMxxxWG-BB PowerXT-xxxR-(AC/P D/B D) OYEAK DUO XL-G9/G9.2/G9.3 Eldora, Solaria PowerXT-xxxC-PD OYEAK DUO(BLK) ML-G10(+) PowerXT-xxxR-PM (AC) Vikram Solivo, Q.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Somera Q.PEAK DUO BLK ML-G10+/t SolarWorld Sunmodule Protect, Sunmodule Plus Waaree AC&Adiya Series Alpha (72) (Black)(Pure) SS-M-360 to 390 Series, Winaico WST&WSP Series RECxxxAA PURE-R RECxxxNP3 Black SS-M-390 to 400 Series, Ymgli YCE&YLM Series N-Peak(Black) Sonali SS-M-440 to 460 Series, ZN Shine ZXM6-72, ZXM6-NH144-166 2094 RECSoIar N-Peak 2 (Black) SS-M-430 to 460 BiFacial Series, PEAK Energy Series SS 230-265 PEAKEnergy BLK2 Series SunEdison F-Series,R-Series & FLEX FXS Series PEAKEnergy 72 Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information SS Ntsr- BLtJELntertek Lntertek ��N SOLAR AUTHORIZATION TO MARK AUTHORIZATION TO MARK Total Quality.Assured. Total Quality.Assured This authorizes the application of the Certification Mark(s) shown below to the models described in the Products) This authorizes the application of the Certification Marks) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be i applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer ��' Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Control Number: 5003705 Authorized by: +r'r A Control Number: 5014989 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C us C us Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client,Intertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Imertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned hnnrted to the terms and conditions of the agreement Intertek assumes no liability to any party.other than to the Client In accordance with the agreement,for any loss,expense or damage Occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark Is by the use of this Authorization to Mark Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Inlertek's Certification mark is restricted to the conditions lard out in the agreement and in this Authonzation to Mark Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must rust be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Standard(s): Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued: 17-May-2023 ED 16.3.15(1-Jul-2022)Mandatory ED 16 3.15(1-Jul-2022)Mandatory DRAWING NUMBER C S�/ Nor- BLUE RAVEN Intertek Intertek SOLAR AUTHORIZATION TO MARK AUTHORIZATION TO MARK Total Quality Assured Total Quality.Assured This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made In accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made In accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Control Number: 5019851 Authorized by: Law �_,,ii Control Number: 5021866 Authorized by: awl" for L. Matthew Snyder, Certification Manager for L. Matthew Snyder. Certification Manager C Us C US 0%" (.rarED Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Interlek's Client and is provided pursuant to the Certification agreement between Intertek and its Client,otertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client,Intertek's respensibdity and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party.other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement Intertek assumes no liability to any party,other than to the Client in accordance with the agreement.for any loss.expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark Only the Client is authorized to permit copying or distribution of this Autho,tzation to Mark and then only in its entirely.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark_Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems,Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] Standard(s): Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide. PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued: 17-May-2023 ED 16 3.1511-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandal-, DRAWING NUMBER C S�/ Nor- Lntertek Listing Constructional Data Report (CDR) tntertek Listing Constructional Data Report (CDR) BLUE RAVEN Total Quality.Assured. Total Quality.Assured. AR 1.0 Reference and Address 1.0 Reference and Address Report Number 102393982LAX-002 Original 11-A r-2016 Revised: 5-Oct-2022 Report Number 102393982LAX-002 Original 11-A r-2016 Revised: 5-Oct-2022 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use Email Standard(s) with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] Applicant Unirac, Inc Manufacturer 2 1411 Broadway Blvd NE Address Albuquerque, NM 87102 Address Country USA Country Contact Klaus Nicolaedis Contact Todd Ganshaw 505-462-2190 Phone 505-843-1418 Phone FAX NA FAX klaus.nicolaedis@unirac.com Email toddg@unirac.com Email Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 5 Address Country Contact Phone FAX Page 1_of 138 Page 2_of 138 This report is for the exclusive use of IMertek's Client and is provided pursuant to the agreement between Interteh and its Client InteROk's respons br.:y and This report as for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client Intertek'S responsb ty and kabirty are netted to the terms and conditions of the agreement tntertek assumes no liability to any party other than to the Client in accordance with the liabkty are limited to the terms and conditions of the agreement 1Mertek assumes no Irablrty,to any party other than to the Client in accordance with the agreement for any lass,expense or damage occasioned by the use of this report Only the Client is authorized to permit copyxmg or distribution of ttrs report and agreement,for any loss expense or damage occasioned by the use of this report Only the Client is authorized to permit copyrmg or distribution of this repot and then only in its enbrety Any use of the Intertek name or one of its marks for the sale or adveNsennent of the tested material. product or service must first be then only in its entirety Any use of the Wertek name or one of its marks for the sale or advertisement of the tested material. product or service must first be DRAWING NUMBER: appra✓ed in writing by Intertek The observations and test results in this report are relevant only to the sample tested This report by itself does not imply that the approved in writing by Intertek The observations and test results in this report are relevant only to the sample tested This report by itself does not imply that the material product,o service a or has ever been under an Intertek certification program material product,or sery ce rs or has ever been under an Inteitek certification program S Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-A r-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-A r-2016 p 9 p p 9 p Unirac, Inc Revised: 5-Oct-2022 Unirac, Inc Revised: 5-Oct-2022 BLUE RAVEN 2.0 Product Description 2.0 Product Description So[ Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Models Unirac SFM Brand name Unirac Model Similarity NA The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to Fuse Rating: 30A photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails Module Orientation: Portrait or Landscape within this product, whereas the 3" Micro Rail, Floating Splice, and 9"Attached Splice Maximum Module Size: 17.98 ft2 electrically bond the modules together forming the path to ground. UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate Increased size ML test: the anodized coating of the photovoltaic module frame (at bottom flange)to contact the metal, Maximum Module Size: 22.3 ft2 creating a bonded connection from module to module. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG355S2W-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating:46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope revision in effect in the jurisdiction in which the project resides.Any local electrical codes must LG395N2W-A5, be adhered in addition to the national electrical codes. The Grounding Lug is secured to the LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. photovoltaic module, torqued in accordance with the installation manual provided in this Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" document. IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Other optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same Certifications, & Increase SFM System UL2703 Module Size: engage cable. Maximum Module Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5"gap between the bottom of the module and the roof's surface See section 7.0 illustractions# 1, 1a and 1b for a complete list of PV modules evaluated with these racking systems Other Ratings NA DRAWING N(UUMBB,ER(/�, ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory F DENTAL RDOFTOP 9311LAR PE/I ITPACKAG E Enphase =� Platinum BLUE RAVEN Kenneth Henry Installer � pp..�� 1403 N 630 E 17601 �.1 int Andrews Ct — Orem, Utah 84097 PV Installation WER (800) 377-4480 Professional Arlington, Washington 98223 �NP� Bue Pave n,9:)lar.com ,bott Gurney Authorized -. - #PV-011719-015866 +12064788506 SC O PE O F WO RK SHEET I N DEX p INSFALLATION OFRDOFIOPMOUNTED PV1 C0VE R S4E=T PV2 97EPLAN PHOTVOLTAIC 9DLARSYSIEM PV3 R00FPLAN U PV4 STRUCTURAL I:") .0 PV5 El-C7RICAL 3-LINE NN V PV6 ELECTRICAL CALCULA71ONS �+ N PV7 LABELS i N N PV8 PLACARD O +=_ � p 0 CITY OF AR,LINGTON C: .� 0' � BUILDING DEPARTMENT � Q .. APPROVED o c DATE ��' �`� BY r O F' 0) U e NO CHANGES AUTHORIZED UNLESS APFfRPW@i WeFdiE Q BUILDING INSPECTOR JA v . ay E O l f V •_ G 1 1 Z d 0 g U TYPICAL STRUCTURA L I N FO RM ATI O N NEW PV SYSTEN INFORMATION TOTAL DC SYSTEM SIZE TOTAL AC SYSTEM SIZE U ROOFMATERIAL Comp Shingle AC SYSTEM SIZE 2.9 kW AC ALTO kW DC DJTI° SHEATHING TYPE 093 DC SYSTEM SIZE 4.1 kW DC 2.90 kW AC � e�916114 FRAMING TYPE Manufactured Truss MODULETYPE 10 91fab Sblar 9L--410 HC+ DESIGN CRITERIA RACKING TYPE- _FM INRNfTY Dc� `^9� E- U ATIACHMENTTYPE UVIPAC SFM INRNnYFASHFQT INVERTERTYPE Enphase IQ8PLUSr72-2-US WIND SPEED: 110 4.10 kW DC TOTALATTACHMBVTS 20 1 A' C'4 WIND EXPOSUREFACTOR C AGSYSTW SIZE' Of / RI SK C ATEG O RY: II 2.90 kW AC INFORMATION FOR INSTAI I Sealed For �Q �� �r. ;� GROUND SNOW LOAD: 25 WVISoNS Existing Roof & �, o ROOF SNOW LOAD:25 ECOBEEQTY: 0 ttachment Only r r SEISMIC DESIGN CATEGORY: D 6 LED LI G HTBULB Q TY: 0 L ; I -- �� WEATHERSTATION DATA GENERALNOTES '�'� �rf GISTus �� WEATHER BOEING R�KNG CO _ FR� tom, o Q -- 1/5/24 FSS� tiG�� HIG H TBM P 2%AVG: 29 C DRAWN BY: �N l-� EXTRE M E M I N I M UM TEM R -7°C Sendan Fllmore Dlgita y signed P�DTDAII. AHJ bin A.Calvert APPLICABLE CODES January 5,2024 *2020 NATIONAL=TiC CODE(NM) DRAWING TITLE: City of Arlington WA Date: 2024.01 .05 *2015IMB:VA-BONALBUILDING CODE(IBC) *20151NTEFNATONALFE.9DENT1AL CODE(IM),20151NTEHNATONAL Cover 9ieet UTI LITY C O M PA N Y AND PLLAABING COG CODESAND ALL SFATEAND LOCAL BUILDING, EL.ECTRCAL, DRAWifvG NUMBER 9iohomish County Public UtilitiesDistdct (PT)D) � 1 *Qs`� BLUE RAVEN 1403 N 630 E Orem, Utah 7 W (800) 377-4480 U Bue Piave nSblar.com LL � ca Q 0 , M91 I �_ Z L9 / U I � CY) o r / I ?, rn Q N / I C: 3: C I = � - Q C: \ ® IS a I co Q \ C: M o \ C: C \ ® ® N U o \ I YTS U \ a \ I E I o W z Iz �7 � U � Sealed For �4°4 ai,Tr.��. I 916114 Existing Roof & %! I DC SYSIEM SZE Attachment Only 4.10 kW DC t /I \ / 1 AC S'STW SIZE h I 2.90 kW AC ♦r "055 F"ISONS 1/5/24 J�FS�UNAL Q - SITE PLAN SALE 3/32"= V-0" A° LE{aENp PV SYSTEM SPECIRCA110NS COMPASS °`AWN BY: Bendan Rllmore ROOF-TOP B�AK9� FA-TS] GENERAZOR F�NIOlEPOWER ❑ NL'W NEW PV SYS16Vl /NFOF�YlA710N �oTOAn:.JUVCl10N BOX [BE] ENCLO9JF� AISPANEL F�'O OAAO'TEfCH PV SYS'fBVI PV MODULE (10) 91fab 3�lar 9L410 HC+, POWER RAl1NG: 410 W a January 5,2024 MICROINVBRTFt Enphase IQ8PLU&72-2-U$ POWERRAl1NG: 290 W ()RAwINGnnE UTTLr[YMEFER DAQ AC DIMONNMT M �BACK Ste RanCCT�BN� aRRE MAIN SERVICE PV PRODUClTON HITS -"POWER IRENCH OR DWMING NUMBFR M� PANEL (PV METER HUB+ OVERHEAD 4\* 1 SUBPANEL CB COMBNERBOX VAULT I PROPERTY LINE F1\/2 r`� BLUE RAVEN 1403 N 630 E Orem, Utah 84097 CB UNDffGF0LJND,93WICEUNE (800) 377-4480 f3ue Ravenbbla r.c om AC M POINTOFINIE�ONNEClION Msp�' M U yrn Q N ® ® ® C: 3 C O C — M P1 ° � MODULEQTY: 10cz a-- LLB ® ® ® AZIMUTH: 130 (j) PFFC H: 27 C: > O 79 81 r O >, C AREA: 458 ftz O) U O Q pealed For a E �- Existing Roof & t z S<YUGHT Attachment Only L , O z � E v T � U < A C4 PFUJECTID 04"^s�t41 916114 'r- ��? Dc SrS`EM sr ? 4.10 kW DC JAC SYSTEM SIZE 2.90 kW AC CHIMNEY !r 46dSS FCV;SONS ---- 1/5/24 S�ONIAt ---- ROOF PLAN ---- SCALE 1/8"= 1'-0" PV SYSTEM SPEC I Fl CAT O N S COMPASS DPAwN BY: LEG EN p Brendan Rllmore ROOFTOP BREAKER GENERATOR REMOTE POWER ❑ NEW NEW PV SYSTEM INFO FdVIA710N PI.DTDA I- � � January 5, 2024 JUNCTION BOX F ENCLOSURE F T5 ATSPANR- OR=SINrfCH PV SYSfBVI PV MODULE (10) SIfab SDIar SL-410 HC+, POWER RAl1NG: 410 W Dr�wING r-i- UTILfTYMETER RREg1BACK MICROINVBTIER: Enphase IQ8PLU572-2-U$ POWBRRA-TING: 29OW UTILfTYMETBT a AC DIBCONN�T CT) CTCABINET E] HATCH Fbof Plan MAIN SERVICE PV PRODUCTION HUB S JNPOWIIf TRENCH OR DRAWING NUMEIM IM—E-P] PANE_ � METIER HUB+ OVBR-If54D t%)K F1\/CO E-91 SUBPANE CB COMBINBRBOX �VAULTPROPERTY LINE CEILING J01,917 MAXIMUM MAXIMUM TOTAL ARRAY AREA 17) 213.35 PANEL AZIMUTH PITCH TSTF AREA ROOFMATERAL S- THING TYPE FRAMING TYPE FRAMING SIZE PURJNSSIZE RACKING TYPE ATFACHMENTTYPE ATTACHMENT CANTILEVER TOTALF�OFAFEA(It') 2569.94 COUNT (DEG) (DEG) (%) (ftz) AND SPACING AND SPACING SPACING(S) (C) DISTRIBUTED LOAD(ps1) 2.2 MP1 10 130 27 61 458 Comp Shingle Of Manufactured Truss N4 024in OC Nov.- a4 24 in OC LiNIRAC 93M INRNTTY LN,PAC ERM INRNIN. HAS-KT 72"L/24"P 2a"L�8"P RDOFCOVBGHT(bs) 8,24 470 TOTAL PVAF¢wYWBGHi(Ibs) 470 BLUE RAVEN MP2 0 TOTALPV ATTACHMENTS 20 MP3 0 POINTLOAD(Ibstatt.) 23.5 MP4 0 1403 N 630 E MP5 0 r,„�6 o Orem, Utah 84097 MP7 0 (800) 377-4480 MP8 0 BueFaven ar.com MP9 0 MP10 0 ATfACHMBNTlYF'E WMODULISS-IAtLNOTDCUND_� Unirac SFM Infinity ABOVEFOOFRDGEUNE 0 PV MODULE MAX CANTILEVER PER TABLE AEOV co (C) V PV MODULE SW INFINITY 93M INFINITY U 0 2"MICIORIML 6.5"9'UCE 2^'! N 0) Q 0) V EXISTING FRAMING V.'• _ ROOF MATE IALNOT 1n` .3�. Q -� 9-IOWN FORCLARIY _ — %G��®�///✓Gc .�z% � �0�/:/a//oY�!//%/.r�aOB/1� �6d���/J/B9//9�IIF��6d�t•Z''" ::.ri.-,. f�.//G%/!/!/C/®���: C_ Ca 3V'M IN (1)5116'LAG BOLT EMEED,M BNT r C C Wf1H E'DM WA9-1139 ^' C U V AT04CI-MEiHT�ACING r ._ PER771,13LEABOVE Z At W Q E FRAMING SPACING O *1HISDERILISNOTMEANTI0 BE PERTABEABDVE -C FRAMING DETAIL ANECACTF�NTA�IONOF ATrACHMENTDEfAIL 2 1 EXTE90R WALL 2 "= r_ " 4 a SCALE 1/2"=1'-0" FRAMING ORPV MODULELAYOUT SALE 1-1/2 1 0 z o RIDGE N01M U LANDSCAPE POR PArr PR7JECTID' da 916114 DC SYSTEM SZE 4.10 kW DC AC SYSTEM SZE' p,• C4L 2.90kWAC ��`.• �i` tip F£VISONS Sealed For �� �' Existing Roof & 7 A 0 - Attachment Only 46056 DRAWN BY: Brendan Fillmore SS�ONAL PLOT DATE January 5,2024 1/5/24 DRAWING TITIF gtuctural FOLLOW AlTACHM ENTSPACING INTABLEABOVE DRAWING NUMBER EA VE *ATrAC HM t3NT PATIB:V SNO LLD BE R/4 ATFA C HM ENT PA TrEFN SrAGG ERD UNLES30lHERWIg r 3 SALE 1/4"=T-0" NOTED IN ENGINEERING LErrER L, ( ) 10AWGlFtiN/1FfiNN-2CULiACK L1 (1) 10 AWG-P-H1,1T1WN-2CUF3ACK 3/4?NCI; L1 (1) 10 AWG T-HN/lHWN-2CUBLACK 3/4INC�- L1 (1) 12AVVGT-9�ylHWN-2CULiACK Nlr5- 4 L2(1) 10 AWG IFHN/IHMrN-2 CU R® L2(1) 10 AWG IHHN/TFMM-2 CU FED C-M 7 n 12(1) 10 AWG T-Frq/T-M/N-2 CU RE L2 (1) 12 AWG 7HHW 7HWN-2 CU R� N (1) 10AWGlH1N/IHWN-2CUFED G (1) 10AWG-THHWIFMVN-2CUGF�V L G (1) 10AWG71-HWIFWN-2CUGR93J G (1) 6AWGB4FE,CU G (1) 10AWGIFHN/TFM/N-2CUGF03V "TYIELJ FCABLEMAY13EaBSITUTEDFORLEEI N 'IVPENM(ROMD)/IJFCABJ 1SFBFivFTIDFORINIEiOR BVR lA9 0-CAf3E 2-W�.R�AIR 6Rerio BLUE RAVEN 3/41NCH EMT L�tenor CONDLAfWHEENBC CODE PERMITS Oil ATTIC R.NSAND9-�ALLBEI WI-EN NEC CODEF�Af15 1403 N 630 E Orem, Utah 84097 (800) 377-4480 Bue Pave ncbla r.c om PRMARY PV COMBINER BOX OVERHEAD SERVICE O 5A 0—PR M A RY STRUCTURE--O 120/240 VAC,601 O O(10)PV MODUILS US 1 PHASE_3 WIFE AC DISCONNECT oB 8 MICRDINVEA SAFETY SWITCH (N)20A QD Q C-Ulolly Meter i q 200A Main Service Panel 30A NON-R19BLE -- PV CIIZ;Uf(1 Pb ARRAY 1` Q I (E)2DOA N I (EL) j J co U) (EL) - N 0 Q N � ?!20) C N (te) ---- -----------------------------------------------G -� _ O) r ---------------- .1 O c c U (EQ (Z z Q (Pll)20A I �+ N c: I U 0 --------------- E O L � Z c < a Z Es G EN EPA L NOTES L) U Utility Meter Number.85425318 AU Load side breaker in M91.InteriorPOI 4 � U � dM1► r.� PFJECTID. (E) EXISTING (w) PV BREAKER (N) NEW (RIEJ FACTORY INSTALLED BF�AIEi t • O w• .e r o rw . t� DC SYSTEM 97J= (a) EXISTING LOADS S'D 9JFGEPF0TE0TIVEDEVICE ) �►"� O 4.10 kW DC (R) RELOCATED LOADS MI MErHANICALINIffiOCK flRl X � +)1 AC SYSTEM SIZE EQUIPMENTNOTES r EQUIPMENTDESCRIMNS /■■ 2.90kWAC RNALCONRGURATIONOFPV CIFCUFTSI rA O BEDECIDEDBYINSLE.MLJSFCOMPLYWf1HMAX V PV MODULE 91fab% 9L- Iar410 HC+,410W DC,LL1703/UL6173000MPUANT r r� F"ISONS O MICFl71NVB TE6FEiCIFCUrrASUSI®ONATrACHEDS'E31-9iEET ®MICFOINVffiTER BVPHA9=IQ8R11S72-2-1J$290 W AC(0.290IcV1/),1 R-IA9=,1JL1741 COMPLIANT I Q W O u^RDOFTOPJUNCTON BOX:EZ9DLARJB,1.2JLJNCTION BOX I A JUNCTION BOX:PVC 4 X4 JLNCTION BDX - A O3 U PV COMBINE BOX:ENRIAS=IQ COMBINER4(X IQ-AM1-240-4) C fl MLARED SAFIEy9NrTCH 30A,2P,240VAC,NON-RJ9R_E(DLJ221 R3) Y H DRAWN BY 0 Brendan Rllmore O6 QJ T' PLOT DATE O Q January 5,2024 © ' DRAWING TITLE O U OTHER NOTES Bectrical ON < GFOLINDINGB DESYSEEM81ALLBEINACCOFDANCEWFTH NBC 250.53. O 3-Line 10 DRAWING NUMBER 1t Fl\/5 OSINX . 0 INTEROR CONDIJITMU5TB=9✓H 80 PVC. 12 N05- ='TRCAL INFO RMA- WIRE SIZE SPEC IFICATONS BLUE RAVEN UnUTY ELBC1FiICALSYMEM O OO 0 O OO 0 O OO 0 10 7 Phis^..,3-Wne,601-14 1201240V MINIMUM CONDlJC10RAMPACIIY 15.13AAC 15.13AAC 15.13AAC 15.1AAC ---AAC ----A AC --A AC --A AC ---A AC --A AC 1403 N 630 E NEW PV SYSrEM CONDUCTORMA-TERAL CU CU CU 1-Fhaw,3-Wire,60Fir. 1201240V CONDUC7CH TYPE L �rll MN-2 IHHWlHWN•2 1}+4%ITt WN-2 lFHN/1FWN-2 -- -- "' -"" - Orem, Utah 84097 AC SYSTEM SIZE 2.9kWAC CONDUC-TORSZE 12AWG 10AWG 10AWG 10AWG --- (8W) 377-4480 DC SYSTEM SZE 4.1kWDC CONDUCTORAMPACI'IY 30A 40A 40A 4OA --A A A --A -A A ®Ue Pave rlcblar.COm PV MODULES AMENT-TENPEPA-TUREADJUl41MENTFAC70R BI QUANTITY 10 CONDUITRLLADJUSEM ENT FAG-TO R 1 1 1 1 TYPE 9Kab Sblar9L-410 HC+ ADJUSTED CONDUCTORAMPACITY 30A 40A 40A 40A --A --A - A --A —A A WATTAGE 41OWDC WIFE RJN DISTANCE 66 75 20 5 "" - MICFIOINVBTTE3S CALCULATED VOLTAGEDFDP 1.34% 0.96°/, 0.26% 0.06°/ 0% 0°/ 0°/ 0% 0°/ 0% -TYPE Eiphase IQBPLL&72-2-L14 OIJEPUTCUFIRBNT 1.21A AC NOMINALVOLTAGE 240VAC PV CIRCUITSPECIRCA110NS OUTPUTPOWER 29GWAC PRIMARY SrRLr-TURE DETACH®STFUCTURE ECIRCUIT1IFCUIT2 CIFCUIT3 CIF�UIT4 CIFCUIT5 CIFCUIT6 CIFCUIT7 CIFCUIT8 CIFCUITI CIFCUIT2 CIFCUIT3 CIFiCUIT4 CIFUU115DESIGN LOCATION NUMBER0FM0DULESPERCIF�UIT0 0 0 0 0 0 0 0 0 0RA7EDAC OLIPUTCUFR NT(I—) O.OA O.OA O.OA O.OA 0OA O.OA O.OA 0.0A O.OA O.OA O.OA O.OAMAN D TBVI PERATURES MINIMUM AMPACITY(I.'x 125%) O.OA O.OA O.OA 0.0A O.OA 0OA O.OA O.OA O.OA O.OA O.OAOVEFGUFFENTPF07EC710N RATING20A 20A 20A 20A 20A 20A 20A 20A 20A .O 20A 20A N DATA SOURCE A9IPAE Weather aation Data 12,1A O.OA COMBINED AC OUTPUTCUF4-TBNT(Co.-) N STA-TE Washington MINIMUM AMPACHY(C—x 125%) 15.1A O.OA CITY Arlington COMBINED PV BREAKERRAllNG 20AA OAA a + 0 WEA-THERSTATION BDBNG FLD KING CO 6) 0 HIGHTEv1P2%AVG 29`C ECIFEIAEMINIMUMTEVIP -TC TOTAL Q c: PV BREAKERBACKFEED CALCULATIONS VOLTAGE DROP N c Q VOLTAGEDFiDP ry�{� .� NED 70512(p-"120°/FILE' WIRETAG#1 1 34% 0 (E)USBARRATING.1200/4-OCPD RATING=AVAILAELEMCMTM WIRETAG#21 0.96°/ c: r^^ c >1 C MAIN SERVICE SUBPANEL WIRETAG#3 0.26% 11J +• �_ PANEL 1 SUBPANEL2 WIRETAG#4 0.069/- CCCC�LLLLJJJJ O BUSBARRATING 200A --A .---A WIRETAG#5 00/0 V WIRETAG#6 0*/ r PANELOCPD RATING 2DOA --A ---A Q -� AVAILABLE BACKFEED(120%RULE) 40A ##A ##A 70TAL 2.620000% PV BFIEAKERRA7ING 20A 20A 20A E '7HERFCALCULA77ONSAFFONLYAPRJCABLEIF 0 PV W7ERGONNE�710N/SA LOAD 57DEa'9EAKEFr 'PV BF€AKERMLASrBER47LD LESS7HAN OROUAL70 0 A VAILABLEB4 CKREM FOR CODECOMPLIANCE' W ' Z a C � C U Q -� PFOJIOTID: 916114 DC SYSTEM SZE, 4.10 kW DC AC SYSTEM,SI.!:, 2.90 kW AC REVISONS A 0 -- DRAWN BY: BIrendan Fillmore PLOT DATE January 5,2024 DPAWING TITLE Bect6cal Calculations DPAW N,G NUMBER Fl\/6 WARNING LABELS FOR PHO-TOVOLTAIC SYSfB\A BLUE RAVEN U11LIlY M EFER MAIN SERVICE PANR AC DISCONNECT 1403 N 630 E Orem, Utah 84097 (800) 377-4480 PHOTOVOLTAIC SYSTBuePavena)Iar.com I AC DISCONNECT ! RATED AC OUTPUT CURRENT 12.1 A NOMINAL OPERATING AC VOLTAGE 240 V 0 QWARNING . ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND V LOAD SIDES MAY BE ENERGIZED PV COMBINER BOX N � IN THE OPEN POSITION CV SOLAR PV SYSTEM EQUIPPED NET METER WITH RAPID SHUTDOWN Y fA j N PHOTOVOLTAIC SYSTEM � ilaRN RAPID SHUIOOWN +J SWITCH TO THE OW POSITION TO COMBINER PANEL = � 0 SHUTDOWN PV SYSTEM "SHOCK HAAZZAARD QWARNING � MI THE ARRAY AUTHORIZED � Q �7 C PERSONNEL ONLY � C j Q IF DO NOT ADD LOADS > •- NO DC WIRES PRESENT c: C RAPID SHUTDOWN r O TEST NOT REQUIRED . U 0 Q E 0 r W n �z 2Z a c L) < 7 PRDJE'—TID CAUTION 916114 MULTIPLE SOURCES OF POWER DC SYSTEM ST 4.10 kVV DC POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED AC SYSfHvI SOLAR ARRAY PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE 2.90 kVV AC OF SIGHT OF UTILITY METER. REVISIONS Q -- A ---- QWARNING_ 0 ---- DUAL POWER SUPPLY Q WARNING SOURCES:UTILITY GRID AND POWER SOURCE DRAWN BY PV SOLAR ELECTRIC SYSTEM OUTPUT CONNECTION 13rIendan Fillmore DO NOT RELOCATE THIS PLOTDATE OVERCURRENT DEVICE January 5,2024 7-7 'LABEL INSAL I ED DRAWINGTT-E. Y, NDCTTp PV BSA KER Waming R Labels DRAWING NUMBER LABELSWr[H ROUND CORNERSAFEADHESVESnCKB:7S Fl\/7___j LABB-SWf1H90U PL AF1ECORNERSAFEASnC ENGRAV®PLACAFOS • B 0 a ELECTRICAL SPECIFICATIONS 410 ® • Test Conditions STC I NOCT E RAVEN • PRIME S I L FA B • Module Power(Pmax) Wp I 410 306 SILFAB Maximum power voltage(Vpmax) V 38.99 36.24 5 O L A RG Maximum power current(Ipmax) A 10.52 8.43 Open circuit voltage(Voc) V 45.59 42.76 S I L-410 H C, Short circuit current(Isc) A 11.15 8.99 Module efficiency % I 20.7% 19.3% Maximum system voltage(VDC) V 1000 Series fuse rating A I 20 Power Tolerance W p 0 to+10 Measurement conditions:STC 1000 W/m'•AM LS•Temperature 25-C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty s 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+IOW. MECHANICAL PROPERTIES I COMPONENTS METRIC IMPERIAL Module weight 21.3kg±0.2kg I 471bs±0.41bs Dimensions(H x Lx D) 1914 mm x 1036 mm x 35 mm 75.3 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)' ` 5400 Pa rear load/5400 Pa front load 112.8 tb/ft'rear load/112.8lb/ft'front load Hail impact resistance a 25 mm at 83 km/h o 1 in at 51.6 mph 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC Cells 9 busbar-83 x 166 mm I 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, anti-reflective coating anti-reflective coating Cables and connectors(referto installation manual) 1350 mm,a 5.7 mm,MC4from Staubli 53 in,0 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, Fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box I UL3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc +0.064 VC Module product workmanship warranty 25 years" Temperature Coefficient Voc -0.28%/•C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.36%/'C >_97.1%end lstyyr >_91.6%end 12th yr NOCT(±2•C) I 45•C >_85.1%end 25th yr Operating temperature -40/+85•C i 82.6%end 30th yr CERTIFICATIONS I SHIPPING SPECS UL61215-1:2017 Ed.1,UL61215-2:2017 Ed.1,UL 61730-1:2017 Ed.1,UL61730-2:2017 Modules Per Pallet: 26 or 26(California) Ed.1,CSA C22.2a61730.1:2019 Ed.2,CSAC22.2M61730.2:2019 Ed.2,IEC 61215.1:2016 Product Ed.1,IEC 61215.2:2016 Ed.l,IEC 61730.1;2016 Ed.2,IEC 61730.2:2016 Ed.2,IEC 61701:2020(Salt Mist Corrosion),IEC62716:2013(Ammonia Corrosion),CEC Listing,UL Pallets Per Truck 32 or30(California) Fire Rating:Type 2 I Modules Per Truck 832 or 780(California) Factory IS09001:2015 O Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.corn PAN files generated from 3rd party performance data are available for download at:si lfabsolar.com/downloads 1 75.3•[1914mm] - `v E _ 12.1"[307mm]_ 51.2[1300mm] 12.1"[307mm] RELIABLE EN E R G Y. ► ' [LFsOLARi[ec. DIRECT FROM THE SOURCE . Mounting Hole(x4) o ' 1 ,�.-a��- _ 1 800 Cornwall Ave ' OV Bellingham WA 98225 USA �[12mm] T+1360.569.4733 Designed to outperform. �'2023 info@silfabsolaccom _ 1770 r GLv R.COC Dependable, durable, high-performance -" d i-----ll--t S _E E E 1770 Port Drive u� „ ,.� �� w E £', rn Burlington WA98233 USA solar panels engineered for North m 1.4"[35mmL �[ OL. a E m mo T+1360.569.4733 American homeowners. ��� 1,`=-= tiS N cy " 240CourtneyparkDriveEast A -- m Ci E_ Mississauga ON L5T 2Y3 Canada 73 53.15" F+1905.696.0267 J! F k B S C L FC .C C) [ N E on r+19os.zss.2so1 0.06" 1� [1.5mm] - [1350mm] m c Cable Length Silfab-SIL-410-HC+-20230726 No reproduction of any kind is allowed without permission.Data and information is subject to Drainage Hole(x8) O I9 modifications without notice.®Silfab Solar Inc, 22 D sDfabSoflah9ocar°isaregis[eredtademad of U}x4WiNG NUMBER� �� :% �I 111_r''L)�{'E ..� LJ �rr�ui n io t i �.,n ����i = �. ��� �n;�_ .� _ 2.4"[60mm]r 8"[200mm] SS BLUE MAVEN ENPHASE. � IQ8 and IQ8+ Microinverters 1403 N.Research Way Orem,UT 84097 INPUT DATA IDCI •' 800.377.4480 Commonly used module pairings' W 235-350 235-440 WWW.BLUERAVENSOLAR.COM 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 CONFIDENTIAL-THE INFORMATION Module compatibility 60-cell/120 half-cell half-cell HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE MPPT voltage range v 27-37 29-45 EXCEPT BLUE RAVEN SOLAR NOR 25-58 SHALL IT BE DISCLOSED IN WHOLE OR 25-48 Operating range v IN PART TO OTHERS OUTSIDE Min/max start voltage v 30/48 30/58 RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND Max input DC voltage v 50 60 USE OF THE RESPECTIVE EQUIPMENT WITHOUT THE WRITTEN PERMISSION Max DC current'[module Isc] A 15 OF BLUE RAVEN SOLAR LLC. Overvoltage class DC port 11 DC port backfeed current mA 0 NABCEP PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit CERTIFIED OUTPUT DATA(AC I 108-60-2-US Peak output power VA 245 300 PV INSTALLATION Max continuous output power VA 240 290 PROFESSIONAL Nominal(L-L)voltage/range' V 240/211-264 Scott Gurney Max continuous output current A 10 121 #PV-011719-015866 IQ8 and IQ8+ Microinverters Extenedfrequen al frequency xz 60 CONTRACTOR: Easy to install Extended frequency range Hz 50-68 BRS FIELD OPS 385-498-6700 Our newest I08 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with AC short circuit fault current over 2 defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors 3 cycles Arms power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication Max units per 20 A(L-L)branch circuit° 16 13 is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components Total harmonic distortion <5% microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced Overvoltage class AC port III 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple A 30 to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling AC port eed current m energy systems. Power facactortor setting 1.0 High productivity and reliability Grid-tied power factor(adjustable) 0.851eading-0.851agging Produce power even when the Peak efficiency % 97.5 97.6 Enphase grid is down" CEC weighted efficiency % 97 97 25 More than one million cumulative Night-time power consumption mW 60 hours of testing Class I[double-insulated MECHANICAL DATA -400C to+600C(-40OF to+1400F) Ambient temperature range enclosure Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability Relative humidity range 4%to 10 Microinverters Microinverters integrate with the Enphase 10 Battery, standards with more than one million cumulative Optimized for the latest high- MC4 Enphase 10 Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- DC Connector type and analysis software. leading limited warranty of up to 25 years. powered PV modules Dimensions(HxWxD) 212 mm(8.3')x 175 mm(6.9')x 30.2 mm(1.2") Microgrid-forming Weight 1.08 kg(2.38lbs) Complies with the latest Cooling Natural convection-no fans wp=c advanced grid support— Approved for wet locations Yes CERTIFIED Remote automatic updates for Pollution degree PD3 DRAWING BY: the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as Configurable to support a Wide NEMA Type 6/outdoor Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with g pp Environ.category/UV exposure rating cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles PLOT DATE: manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 requirements Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to PROJECT NUMBER: manufacturer's instructions. ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other 'Only when installed with IQ System Controller 2, (1)No enforced DC/AC ratio.See the compatibilitycalculatorat https://link.enphase.com/module-compatibility names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. •'108 and I08PIus supports split phase,240V (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IOBSP-DS-0002-01-EN-US-2022-03-17 SHEET NAME SPEC SHEET REVISION: PAGE NUMBER: ---- SS Yr,Z Data Sheet Enphase QCable Accessories BLUE RAVtN Enphase Q Cable Accessories CONDUCTOR SPEC FICATIONS Certification UL3003(raw cable),UL 9703(cable assemblies),DGcable Flame test rating FT4 Compliance RI FtES I,CE,UV Resistant,combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Enphase The Enphase Q CableTmand accessories are part of Disconnecting means The ACand DCbulkhead connectors have been evaluated and approved by UL for useas the load-break the latest generation Enphase IQ SkjstemT""These disconnect required by NEC 690. Q Cable Accessories accessories provide simplicity,reliability,and faster Q CABLE TYPES/ORDERING OPTIONS Installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Q-12-20-200 12 AWG/277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 EN PHASE Q CABLE ACCESSORI ES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Feld-wireable connector(male) O-CONN-10M Make connections from any open connector • Two-wire,double-insulated Enphase Q Cable Feld-wireable connector(female) Q-CONN-10F Make connections from any QCable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Enphase cable Disconnect tool Q-DISG10 Disconnect tool for QCable connectors,DC connectors,and AC module mount • New cable numbering and plug and play connectors speed up installation and simplify QCable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling wire management Terminator Q-TEFIM-10 Terminator cap for unused cable ends • Link connectors eliminate cable waste Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4(TE PV4-S SOLARLOK). 150mm/5.9"to MC4. Enphase EN4 non terminated adaptor' ECp Q•14 FW For field wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non terminated cable.150mm/5.9" Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use with split Feld-Wireable Connectors cell modules or PV modules with short DC cable.600mm/23.6" • Easily connect Qcables on the roof without Replacement DC Adaptor(MC4) Q-DCG2 DCadaptorto MC4(max voltage 100 VDC) complexwiring Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable within 1.Qualified per UL subject 9703 branch limits • Available in male and female connector types - TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) W (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL r CABLE CLI P Plan to use at least one per Used to fasten cabling to the racking installation,sold in packs of ten or to secure looped cabling,sold in (Q-DISG10) packs of one hundred(Q-CLIP-100) To learn more about Enphase offerings,visit enphase.com C 2020 Enpnase Energy.All rights reserved.Enphase,the Enphase logo.Enphase IQWA Enphase I013attery,Enphase Enlighten,Enphase IQ EN P H A S E. Enwy,and other trademarks or service names are the trademarKs of Enphase Energy.Inc.Data subject to change. E N P H A S E. DRAWING NUMBER To learn more about Enphase offerings,visit enphase.com �� 2020-06.26 ISI SS BLUE RAVEN IQ Combiner 4/4C 1403 N.Research Way Inphase Networking MODEL NUMBER Orem,UT 84097 UNIP qrn-iE F'V;)Nl[LICliG0 rrW fribini-,4 800.377.4480 a,,j �,;jr r,,r.Ijj itt.7lairti rirr LMIlVI, Iiiii]-lu AM 1 261 WWW.BLUERAVENSOLAR.COM -11: )I,':r;p'-lll';r'f 1,; rTjX! CONFIDENTIAL-THE INFORMATION Y,:�j It T."ll-I'l. .C'L_VF;DEVJ/,: 0(i J HEREIN CONTAINED SHALL NOT BE i'IdL��Jl j'adc uE :,r,7 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR IQ Combiner 4/4C DISCLOSED IN WHOLE OR -)d r',-u d _jjvj 1L, SHALL IT BE ACCESSORIES AND REPLACEMENT PARTS 2;-.-ot tiric-Licitcid,C'rr'&.5 Epar IN PART TO OTHERS OUTSIDE drill , RECIPIENTS ORGANIZATION,EXCEPT - IQ8i IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. L"L LJ 311.0�:'I.fit V."rl!; Il (T.1 7.,T j A "I I r -i Fl�'�o BR*_jul� NABCEP a 4 i-I -V,;'k-d --S L':!UT 1 6 CERTIFIED Ll FI Ur I t!;[ _.7�lu'-�"'ak 2uA,vaiuri BF220��Mill huld di- a S S o--!771 v P:�•2,0 A F;-2 4["11)b PV INSTALLATION Lh t'.), PROFESSIONAL Scoff Gumey x 1-G 5A du'rW,111 l't L'001' M o:.oery #PV-01 1719-015866 T ;rvtt co w-ra n ari f.-arn irr, CONTRACTOR: zmat I ELECTRICAL SPECIFICATiONs BRS FIELD OPS Includes IQ ano 385-498-6700 2401vx-C 6C,H, `,11 Of,SF-051,Ir.,lLided oqi.v v.-ilti 7 C-arn In pe r SC lrwludi�F solar:flit-Id r,)inali.`7,Efiph,]SE,10 'Arld jellect heal �%'j-Fi,Elllf'.rriel.or i7ellular culiwcrtvit'4 • oplirrtal fu:�Opt�rc;,-evmlittle fi,r PLC'wLige Up lo ll"'!( E111"n!"V.rim'vE 1;1 d �'tle m Card tf-�ring MECHANICAL DATA 'Y 5 in i j K!1:1,1 pi or%.1,)uTlis c,", Fmd ivoh c�:nterett hrac�.i•ls X2-iQ-,6A11,-24D-4C IIl EE IS,-,l 518, IS j p 0 C'r-,;"10 1-1 cr-1,b a c 6:Uri d'":I'd C. J 0 r t I]u I ke n'I v A.jjcpj,s jp 1,)foLiT"-pcijE- cl-currr for r 40VAIC plug-ifi D.reax£,rci InDl dncuded',' 0i!rll.E-.6E%!.,,tv'�K 1P.Ou., JIL011DIk'I IWO 'I' ii PIV u, 5torage E'� Reiiable I r4FMA ,ypi-IP endzisutc jp T" iyt.)f",A[lviniit,d v;.jtrdi'j!y, labor reim)LrsenEnl prrqrzj,-,i INTERNET CONNEC71ON OPTIONS !TEE!:[ I X4QW01-240-d �.2 a,jr3 i;i.%','I--,I0-,.F--orripi'i ,I h X2-IQ-AM1,240--lIIEFE)S17 21102! [FEE JTPPI�vrim A,!i, ln�ll COMPLIANCE Srj SP. 'Fr i X 1-1 11;'"..-Irj t.M-14T,4[') A Cl C"• 5 Vy PtrjduL7I7._i'i USTED E N P H A S E To 1parn morp aboul Enj-,qhase ailenngs, enPhio�U,iq_QM .00, SHEET NAVL 71[li US SPEC SHEETS REVISION: rnGE NUMBER: 0 SS BLUE RAVEN Data Sheet Enphase Networking 14oem Research Enphase IQ Envoy 600.377.4480 WWW.BLUERAVENSOLAR COM MODEL NUMBERS Enphase IQ EnvoyT" Enphase IQ Envoy communications gateway with integrated revenue grade PV CONFIDENTIAL-THE INFORMATION E Enphas ENV -IQ production HEREIN CONTAINED SHALL NOT BE metering(ANSI C12.20 W-0.59/4 and optional consumption monitoring(+/-2.5°/�. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR Includes SHALL IT BE DISCLOSED IN WHOLE OR � � IQ Envoy The Enphase 10 EnvoyT"�ommunications gateway one 200A continuous rated production CT(current transformer). IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT delivers solar production and energy consumption —ACCESORI ES(Order Seperately) IN CONNECTION WITH THE SALE AND Enphase Mobile ConnectT"' Plug and play industrial grade cellular modem with data plan for systems up to 60 USE OF THE RESPECTIVE EQUIPMENT, data to Enphase Enlighten TMmonitoring and analysis CELLMODEM-M1 (4Gbased LTE-M/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin WITHOUT THE WRITTEN PERMISSION CELLMODEM-MI-B(4G-based LTE-Mi/5-year data plan) Islands,when:there is adequate cellular service in the installation area.) Consumption Monitoring CT Split-core OF BLUE RAVEN SOLAR LLC. software for comprehensive,remote maintenance and lit-core consumption CTs enable whole home metering. management of the Enphase IQSystem. CT-200-SPLIT NABCEP Ensemble Communications Kit Installed at the IQ Envoy-For communications with Enphase EnchargeT"'storage COM MS-KIT-01 and Enphase EnpowerTwmart switch.Includes USB cable for connection to IQ CERTIFIED] With integrated revenue Cade reduction metering Envoy or Enphase IQCombinerT"'and allows wireless communication with Encharge eg 9 P g and Enpower. PV INSTALLATION and optional consumption monitoring,Envoy IQ is the POWER REQUI REM ENTS PROFESSIONAL platform for total energy management and integrates Power requirements 120/240 VACsplit-phase. Scott Gurney Max 20 A overcurrent protection required- #PV-011719-015866 with the Enphase EnsembleT"And the Enphase IQ Typical Power Consumption 5w CONTRACTOR: BatteryT"" CAPACITY BRS FIELD OPS Number of microinverters polled Up to 600 385-498-6700 MECHANICAL DATA Dimensions(WxHxD) 21.3 x 12.6 x 4.5 cm(8.4"x 5"x 1.8") Smart Weight 17.6 oz(498 g) Ambient temperature range -40°to 65°C(-40°to 149°F) • Enables web-based monitoring -400 to 46°C(-400 to 115°F)if installed in an enclosure and control Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMAtype 3R enclosure. • Bidirectional communications for Altitude To 2000 meters(6,560feet) remote upgrades Production CT -Limited to 200A of continuous current/250A OCPD-72kW AC •Supports power export limiting and Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) zeroexport applications UL2808 certified for revenue grade metering Consumption CT For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.8N'x 0.96'(21.33mm x 24.38mm)to support Simple 3/0THWN conductor UL2808 certified,for use at service entrance for services up to 250Vac Easy system configuration using Enphase Installer ToolkitTftobileapp INT • Flexible networking with -F, Integrratedated VIA-Fi 802.11b/g/n CONNECTION OPTIONS Wi Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLMODEM-M1 (4G)orCELLMODEM-Mi-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable COMPLIANCE Compliance UL 61010-1 • Designed for installation indoors CAN/CSAC22.2 No.61010-1 or outdoors 47 CFK Part 15,Class B,ICES003 DRAWING BY I EG EN 61010-1:2010, • Five-year warranty EN50065-1.EN61 0 0 0-4-5,EN61000-6-1,E461000-6-2 Metering:ANSI C12.20 accuracy class 0.5(PV production only) PLOT DATE: PROJECT NUMBER E N P H AS E. To learn more about Enphase offerings,visit enphase.com E N P H AS E. SHEET NAME: To learn more about Enphase offerings,visit enphase.com �•� trade- U SPEC SHEET ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,and other trademarks or service names are the trade- marks of Enphase Energy,Inc.Data subject to change-06-30-2021 REVISION: PAGE NUMBER: ---- SS SLUE RAVEN 1403 N.Research Way Orem,UT 84097 WIRING DIAGRAMS 800.377.4480 W W W.BLU ERAV ENSOLAR.COM FUSIBLE NOT FUSIBLE CONFIDENTIAL-THE INFORMATION 6.75 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT ANYONE [1721 EXCEPT BLUE RAVEN SOLAR NOR 28 I I SHALL IT BE DISCLOSED IN WHOLE OR Q IN PART TO OTHERS OUTSIDE [71 -I RECIPIENTS CONNECTION WITH THEE SALE EXCEPT N AND (3 HOLES) A C USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC - S N 9.60 q NABCEP 6.00 [229] - - ? CERTIFIED [152] � A,B,C B D PV INSTALLATION KNOCKOUTS PROFESSIONAL S N Scott Gurney #PV-011719-015866 A,B,C CONTRACTOR: 4.60 4.50 KNOCKOUTS I TERMINAL LUGS$ BRS FIELD OPS [114] [117] AMPERES MAX. WIRE MIN. WIRE TYPE 385-498-6700 # 6 AWG # 12 AWG AL 30 # 6 AWG # 14 AWG CU 7.50 [191] KNOCKOUTS SYMBOL A B C D CONDUIT SIZE .50 .75 1 1.25 A,8,C KNOCKOUTS 0 NEMA TYPE 3R ILLUSTRATED INCHES DUAL DIMENSIONS: MILLIMETERS A,B,C,D KNOCKOUTS HORSEPOWER RATINGS CATALOG VOTAGE WIRING 120VAC 240VAC NUMBER RATINGS DIAG. STD MAX STD. MAX. 10 10 10 30 10 30 D211NRBo■ 240VAC A 1/2 2 1 1/2 — 3 — NOTES: D221NRB 240VAC A — — 1 1/2 3s 3 7 1/2* FINISH — GRAY BAKED ENAMEL ELECTRODEPOSIIIED OVER CLEANED PHOSPHATIZED STEEL. D321NRB 240VAC B — — 1 1/2 3 3 7 1/2 UL LISTED — FILE E-2875 DU221 RB 240VAC C — — — — 3 — DRAWING BY: ALL NEUTRALS — INSULATED GROUNDABLE _ — _ _ 3 7 1/2 SUrrABLE FOR USE AS SERVICE EQUIPMENT DU321RB 240VAC D TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT—ON HUB. SHORT CIRCUrr CURRENT RATINGS: PLOT DATE • 10,000 AMPERES. 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES. GENERAL DUTY SAFETY SWITCHES D 100,000 AMPERES WITH CLASS R FUSES. VISIBLE BLADE TYPE - * FOR CORNER GROUNDED DELTA SYSTEMS. 30 AMPERE by Schneider Electric PROJECT NUMBER: ■ PLUG FUSES ENCLOSURE — NEMA TYPE 3R RAINPROOF Nock 1852 $ LUGS SUITABLE FOR 60-C OR 75' CONDUCTORS. FEBRUARY 2014 REF DWG #1852 sFie:-- un✓e SPEC SHEET REVISION: :'At;F NUMBER --- SS JB- 1 .2 EZf SOLAR PHONE; 385-202-4150 EZf SOLAR Specification Sheet making solar simple, WWW.EZSDLARPRODUCTS.COM BLUE RAVEN making solar simple. PV Junction Box for Composition/Asphalt Shingle Roofs 1403 N.Research Way Orem,UT 84097 A. System Specifications and Ratings ITEM NO. PART NUMBER DESCRIPTION OTY SIZE DWG,NO. REV 800.377.4480 POLYCARBONATE B JB-1,2 WWW.BLUERAVENSOLAR.COM • Maximum Voltage: 1,000 Volts 1 JB 1.2 BODY WITH UV INHIBITORS , CONFIDENTIAL-THE INFORMATION SCALE:1:2 WEIGHT:1.45 LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE • Maximum Current: 80 Amps EXCEPT BLUE RAVEN SOLAR NOR 2 JB 12 LID POLYCARBONATE 1 SHALL N PART TOCLOHE D IN WHOLE DE OR Allowable Wire: 14 AWG -6 AWG TS WITH UV INHIBITORS TORMESPECIFICATION: 15-20 LBS RECIPIENTS ORGANIZATION,EXCEPT • Spacing: Please maintain a spacing of at least 1/2" between uninsulated live parts and fittings for IN CONNECTION WITH THE SALE AND UL STANDARD 1741 USE OF THE RESPECTIVE EQUIPMENT, conduit, armored cable, and uninsulated live parts of opposite polarity. #10 X 1-1/4"PHILLIPS 6 CERTIFICATION: WITHOUT THE WRITTEN PERMISSION 3 PAN HEAD SCREW NEMA 3R OF BLUE RAVEN SOLAR LLC. • Enclosure Rating: Type 31R • Roof Slope Range: 2.5- 12:12 4 #8 X 3/4'PHILLIPS WEIGHT: 1.45 LBS NABCEP • Max Side Wall Fitting Size: 1" PAN HEAD SCREW 6 CERTIFIED • Max Floor Pass-Through Fitting Size: 1" PV INSTALLATION • Ambient Operating Conditions: (-35°C) - (+75°C) PROFESSIONAL • Scott Gurney Compliance: #P p V-011719-015866 - JB-1.2: UL1741 -Approved wire connectors: must conform to UL1741 CONTRACTOR: OPS ° System Marking: Interek Symbol and File#5019942 1 I BRS 3 5 4198 6 00 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. I Table 1:Typical Wire Sue,Torque Loads and Ratings i O� � I 1 1 Conductor 2 Conductor 7wque Type NIM Inch Lbs Voltage Current /� \_ ABR 75b terrrslna9 block 10-24 awg 16-24 awg Sel/Str 0.5-0.7 6.2-8-85 600V 30 amp I ABR 2510 terminal block 6-24 awg 11-20 rwe Sol/Str 1.0-1.6 8.85-14,16 600V 40 amp I I 1 • I ABBZ516 terminal bock 4.24 aws 1Q-20 awg Sol/Str 1,6-2.4 144-21.24 600V 60 amp 1279.68mm ♦)mm� i L2]6.3 A8R WA terminal block 8.22 aw So!/Str 08-1 a-ss 600V 50 amp 1 1,01 in 10.88in f Ideal 452RedWING-NUTWire 818awg WiStr Self Torque Sell Torque 600V E 7= Connector l SOLAR I Ideal 451 Yellow WING-NUT 10-18awg Sol/Str WTorque SeltTorque 600V 1 Wire Connector Ideal,In-Su re Push-In 10.14awg Sol/Str Self Torque SellTarque 600V Connector Part#39 ,B-1 WAGO,2204-1201 10.20 awg 16-24 awg 50/5tr ScIfTorque Sell Torque 600V 30 amp I i WAGO,221-612 10-20 awg 101 24 awg Sol/Str Self Torque Sell Torque 60DV 30 amp I ` DottIeDRC75 6-12awg Sol/Str Snap-In Snap-In ESP NG-53 4-6awR SWISt+ 45 2000V I i 10-14 awg Su!/Str 35 ESP NG-717 4{,awg 5o!/Str 45 2000V 1 ---- 10-14awg 5o1/5tr 35 DRAWING BY: 4-6 awg SnlfStr 45 8rumall4-5,3 2000V 72,.,� 10.14 4".. 505/51r 35 y 1183.06rslrrlj 2.86in y .86i iFrl 7,21 in PLOT DATE: Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) _ [265-18rnrn] Wire size,AWG or Wires per terminal(pole) _ 10,441n PROJECT NUMBER: 1 2 3 r 4 or More kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not specified - SHEET NAME 8 (8.4) 38.1 (1-1/2) 6 (13.3) 50.8 (2) SPEC SHEET REVISION: PAGE NUMBER: WSOLAR PHONE;385-202-4150 1 WWW,EZSOLARPRODUCTS.COM PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFEZSOLAR. SS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. `4�1* BLUE RAVEN - - 1403 N.Research Way Orem,UT 84097 Carlos• Molded Nonmetallic Junction Boxes � B .4480 Except where noted byt E42728 VIEW SHOWN LESS yyyVW.BLUERAVENSOLAR.COM RAV 6P Rated COVER FOR CLARITY 3 7 CONFIDENTIAL-THE INFORMATION [9 4] � Z G HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR It's another first from Carlon®-the first nonmetallic SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE junction boxes LIL Listed with a NEMA 6P rating per RECIPIENTS ORGANIZATION,EXCEPT 0 IN CONNECTION WITH THE SALE AND Section 314.29,Exception of the National Electrical Code. USE OF THE RESPECTIVE EQUIPMENT, Manufactured from PVC or PPO thermoplastic molding 3.70 -- WITHOUT THE WRITTEN PERMISSION compound and featuring foam-in-place gasketed lids [94] 2. 12 ` OF BLUE RAVEN SOLAR LLC. .50 attached with stainless steel screws,these rugged [54] [ 12,7] enclosures offer all the corrosion resistance and physical NABCEP� properties you need for direct burial applications. CERTIFIED] Type 6P enclosures are intended for indoor or outdoor _ PV INSTALLATION use,primarily to provide a degree of protection against PROFESSIONAL contact with enclosed equipment,falling dirt,hose- Scott Gurney directed water,entry of water during prolonged B #PV-011719-015866 submersion at a limited depth,and external ice - - - - - CONTRACTOR: formation. BRS FIELD OPS 385-498-6700 Tc-1 •All Carlon Junction Boxes I W are LIL Listed and maintain j 0 0_ ,c At a minimum of a NEMA Type j 0 0 4/4x Rating. j I I • Pans numbers with an o e o 0 I I C asterisk(*)are LIL Listed and SIZE A B C H Ii i I I maintain a NEMA Type 6P Rating andT a 4/4X Rating. E989NNJ 2.00 4.63 5.13 I 9 Type g' E980NNJ-CAR 150,B1 Illl,fil f130.21 I A 1OL—J, I I E969NNJCL I A - o A�—i i —TB (41102) E989NNR 8.00 5.00 5.50 E9a9 NNR-CAR 1152.4) 1121,01 1139,11 I (4R4X6) j 15 j Size in Std. Material Std. [3,81 j Inches Ctn. Min Min. Min. Min. Ta I Tc Thermo- Ctn. Part No. H x W x D Qty. AT AB B C Typical PVC plastic Wt.(Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 311/16 35/8 N/A 2 .160 .155 X 3 E987N-CAR* 4 x 4 x 4 5 311/16 31/2 NIA 4 .160 .155 X 4 NOTES I. MATERIAL: PVC SECTION A' tE989NNR-CAR* 4x4x6 4 311/16 33/8 N/A 6 .160 .200 X 5 2. NEMA TYPES: 4/4X, 6P C SCALE 0. 500 E989PPJ-CAR* 5 x 5 x 2 4 411/16 41/2 N/A 2 .110 .150 X 3 DRAWING BY: E987R-CAR* 6 x 6 x 4 2 6 55/8 N/A 4 .190 .190 X 3 E989RRR-UPC* 6 x 6 x 6 8 55/8 53/8 N/A 6 .160 .150 X 14 GBERAL NOTES E989N-CAR 8x8x4 1 8 8 NIA 4 .185 .190 X 2 I ALL DIMENSIONS ARE FOR REFERENCE ONLY. m.lnb.com PLOT DATE: E989SSX-UPC 8 x 8 x 7 2 721/32 75/16 N/A 7 .160 .150 X 6 2. DIMENSIONS IN BRACKETS 1 1MOLDED NON-METALLIC ENCLOSURE E989UUN 12x12x4 3 115/8 111/2 111/8 4 .160 .150 X 12 ARE IN METRIC UNITS DESCRIPTION REVISIONS E989R-UPC 12 x 12 x 6 1 2 1115/16 112/8 117/16 6 .265 .185 X 10 F SEE ERN 2016195 PROJECT NUMBER: FOR APPROVAL SIGNATURES ORIGINAL PROJECT NO / I ERN NO I SHEET N0: REV. NO DRAWING NO- PROJECTSNO: 5AM000D06 / [ ) 2 OF 2 F W5D-AC01977 THIS DRAWING IS INTENDED FOR DESCRIPTIVE PURPOSES ONLY. AND THE RIGHT IS RESERVED TO DEVIATE FRDM ANY OF THE DETAILS SHOWN HEREON. SHEET NAME: 180 www.carion.com Copyright Thomas A Betts - Proprie#ory, All Rights Reserved SPEC SHEET Gross Automation(877)268-3700•www.carionsales.com- sales@grossautomation.com REVISION: PAGE NUiMBER ---- SS BLUE RAVtN • , with SalarPower Components pewiffin&eeriaCCompany Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Ultimate in Liquid Tight Strain Relief Protection PRODUCT! GLAND PART NO. DESCRIPTION PART DIMENSIONS -Two new cordgrips now accommodate CONFIGURATION 01 A B C D E the Enphase Q Cable-M3231 GCZ Conductors or Clearance,Max.O.A. Thread Wrenching Nut (1/2""NPT)and M3234GDA-SM Type Size No. Black s916 Hole Dla.l Length Length idmess Flat Size (3/4""NPT). mm. in. Imm. in, mm. in.mm In. mm. in mm. Oval Gland •The 1/2-version provides liquid tight entry for one Enphase Q Cable- Q Cable 6,1 x 9,7 1 M3231GCZ I LTCG 1/2 6.1x9.7MM S/@ .875 22,2 1.70143,2.61 15.5 .21 5.3 .98 24,9 .24 x.38""(6,1 x 9,7 mm). Break-Thru Skinned Over Gland •The 3/4-version provides liquid tight QCables 61 x971 2 SMCG 3/42-6.1x9.7MM I. entryfor u to two Enphase Q Cables- plus 3,3 I 1 M3234GDA-SM 1 3.3MM ®��!(I.040 26,4 2.00 50,8.62 15,7I.25 6.4 1.30 33,0 24 .38"(6,1 x 9,7 mm)and an Ground Metal Locknuts INCLUDED. B additional .130"(3,3 mm)dia.hole for c a#8 solid grounding cable. D A •The 3/4-version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. •Rated for use with DG Cable. SUGGESTED CLEARANCE HOLE SEALING NUT INTEGRAL FOR NONTHREADED MOUNTING SEALING RING Material Nylon 6/6 with TPE Sealing Gland Certifications ® Listed under Underwriters'Laboratories File E504900 SP GSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40oF(-40oC)to 239°F(115°C) Dynamic-4°F(-20°C)to 212°F(100°C) IP Rating IP 68 " ELHeyco®Helios®UVX Clip—Blind Mount PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL •The jersey pine tree mounting style RANGE HOLE DUI. HEIGHT installs easily with superior holding Minimum Maximum 1-2 Wires A C power. in. i n in. mm in. I mm. in. mm. •UVX nylon protects from corrosion due 1-2 Wires to outdoor exposure. .028 0,7 .250 6,4 �23(5,8mm)32(8,0mrn)� 56520 Helios UVX Clip 1001zack 260I 6,6 I.9s 24,4 - Installs into.260-(6,6 mm)mounting each cable S6560 Helios UVX Clip Bulk hole. -� • Holds up to 2 cables between.230- O .315""(5,8-8,0 mm)each. r •Cables install with fingertip pressure. A •Molded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F(-20oC)to 185°F(85°C) DRAWING NUMBEE2 1-800-526-4182•732-285-1800(NJ)•FAX:732-244-8843■www.heyca.com 1-4b SS .. U•om� N I RAC SFM INFINITY gor— ==;Wa b**4 F BETTER SOLAR STARTS HERE `SUM, SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PART NAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY ff TRIMRAIL Structural front trim provides aesthetic and aligns modules Make two installs per day your new standard.SFM INFINITY has fewer bonds sections of TRIMRAIL l roof attachments,one tool installation,and pre-assembled components TRIMRAIL SPLICE Connects and electrically to get you off the roof 40%faster. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. , W SFM INFINITY 15 Attachments MODULE CLIPS Secure modules to TRIMRAIL MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east west bonding. ATTACHED SPLICE also available. with integrated front trim,trim end caps,dark components,and recessed hardware. SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density Vvlth fevver SKUs and compact components,SFM INFINITY is easier to without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES stock,easier to transport,and easier to lift to the roof.Plus,make more attachments required by rail. efficient use of your vehicle fleet. PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. IV TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules 0 N/S BONDING CLAMP Electrically bonds rows of modules • • • • SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS , FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. DRAWING NUMBER ISS ■ ■ i ; BLUE RAVEN SUN SYSTEM BONDINGGROUNDING , 19 ■ n FRAME ; ■� � TMINSTALLATION GUIDE , PAGE S_FM ----------------------------------------------------- -I -- —� 0 e 0 E W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the Microra!LTM and splice. f: Star Washer is VVEEBLUG Single Use Only Single Use Only Alternate method N-S BONDING PATH: TERM I NAL TORQUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERNAINALTORQU15 TERMINALTORQUE, bonding pins. (refer also i0 alternate method) 4-6 XVVG: 35in-Ibs Install Conductor and Install Conductor and 8 AVVG: 25 in-Ibs torque to the following torque to the following: 10-14 A&IG 20 in-Ibs 4-14 AVVG: 35in-Ibs 6-14 AWG: 7ft-Ibs O LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO ' •, *` 11 sco Lay-I n Lug (GBL-4DBT) I I soo Flange Lug (SGB-4) Wi I ey WEFBLug (6.7) • 10-32 mounting hardware 1/4" mounting hardware 1/4" mounting hardware • Torque = 5 ft-lb • Torque = 75 in-lb 9 Torque = 10 ft-lb Alternate method ; • AWG 4-14-Solid or Stranded 0 AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded TRI M RAI L BONDING PATH: NOTE: ISOLATE PPER F►=s)M ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with *stem bonding isa000mplished through modules.System grounding a000mplished byattaching bonding clamp with integral bonding pin and bonding T--bolt. (refer also to alternate method.), NUMBER a ground Lug to any module at a location on the module specified by the module manufacturer. SS NN NW i SUN i BLUE RAVEN 1 Zp SVL ;D ■� ■ FRAME UL CODE COMPLIANCE NOTES NN SFMMICRORAILT INSTALLAONTf-- GU10F_ '_ P A G E _______________________________________________________________________________________________________ SYSTBM LEVEL R RE CLASSI R CATI CAI The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures SUNFRAME MICRORAIL(SFM) Installation Guide.SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTm components shall B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules. Class A, B & C system level fire ModuleType Roof Slope System Level Fire Rating _ Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West , Landscape OR Portrait None Required UL2703 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF / 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa c) Down-Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF / 8000 Pa b) Upward Pressure - 75 PSF/ 3500 Pa c) Down-Slope Load - 32.4 PSF / 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 ® Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or Less D-AWING NtWBER SS ■ i SUN ; o�UE RAVEN � ZZ son , FRAME ; ■ ■ � TM INSTALLATION GUIDE , PAGE S-FM -MICRORAIL------------------------------------------ ------------------ ---------------------------- ----- Manufacture Module Model/ Series Manufacture Module Model/ Series Manufacture Module Model/Series Aleo P-Series Eco Solargy Orion 1000& Apollo 1000 LGxxxN2T-A4 ET Solar ET-M672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ DNA-120-(BF/MF)26 Q1C/Q1K/S1C/S2W)-A5 Aptos , Freedom Forever FF-MP-BBB-370 DNA-144-(BF/MF)26 LGxxxN2T--B5 FreeVolt Mono PEFC LGxxxNl K B6 CHSM6612P,CHSM6612P/HV,CHSM6612M, GCL GCL-P6& GCL-M6 Series LGxxx(A1C/M1C/M1K/N1C/N1K/Q1C/Q1K/ Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), Hansol TD-AN3,TD-AN4, LG ELectronics QAC/QAK)-A6 CHSM72M-HC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W)-E6 AXN6M610T,AXN6P610T, 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 Auxin I AXN6M612T&AXN6P612T Heliene 144HC M6 Monofacial/Bifacial Series, LGxxxN2T-,5 AXIbLackpremium 60(35mm), 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 AXlpower 60(35mm), HT Sol ar HT60-156(M)(NDV)(-F), LGxxx(N1C/Q1C/Q1K)-N5 Axitec AXlpower 72 (40mm), HT 72-156(M/P) i LGxxx(N1C/N1K/N2W/Q1C/Q1K)-V5 AXlpremium 60(35mm), KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(H I B/H I H/HPB/HPH)-xxxM Hyundai AXlpremium 72 (40mm). HiA,&xxHG LR4-72(HIH/HPH)-xxxM BVM6610, ITEK iT,iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30mm) Boviet BVM6612 LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm ,Japan Solar ,PS-60& ,PS-72 Series BYD P6K& MHK 36 Series LONG LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) - JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) CS1(H/K/U/Y)-MS xxx,JAP6(k)-72-xxx/4BB,JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM CS3(K/L/U),CS3K-MB-AG,CS3K-(MS/P) JAP6(k)-60-xxx/4BB,JAP605YY-xxx/ZZ, (35mm) Canadian Solar CS3N-MS,CS3U-MB-AG,CS3U-(MS/P),CS3W ,ygSolar JAM6(k)-72-xxx/ZZ,JAM725YY-xxx/ZZ, � LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm)CS5A-M,CS6(K/U),CS6K-(M/P),CS6K-MS -- JAM6(k)-60-xxx/ZZ,JAM605YY-xxx/ZZ. Mission Solar Energy MSE Series CS6P-(M/P),CS6U-(M/P),CS6V-M,CS6X-P - i.YY:01,02,03,09,10 CentrosoLar America GSeries& E Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi M E& MLE Series CT2xxMxx-01,CT2xxPxx-01, ,KM& JCMS Series Neo Solar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, �- - CTxxxMxx-04,CTxxx H C11-04 J i n ko Eagle,KMxxx M JKMxxxM-72HL-V Dehui DH-60M Kyocera KU Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information DR4WING Nunnso� SS SUN ;TESTED BLUE RAVEN MODULE LIST mom FRAME ; CERTIFIED 23 ON qSFM MICRORAIL TM INSTALLATION GUIDE , PAGE _____________________________________________ -------------------------------------------------- Manufacture Module Model/ Series Manufacture Module Model/ Series Manufacture Module Model / Series EVPVxxx(H/K/PK), TwinPeak Series Suniva MV Series &Optimus Series VBHNxxxSA15 & SA16, TwinPeak 2 Series r A-Series A400-BLK,SPR-MAX3-XXX R, SunPower VBHNxxxSA17 & SA18, TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series REC Solar(cont.) Panasonic VBHNxxxSA17(E/G) &SA18E, TwinPeak25(M)72(XV) Suntech STP,STPXXXS-660/Wnhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38mm) Talesun TP4 Black TP572,TP596,TP654,TP660, VBHNxxxZA01,VBHNxxxZA02, (BLack) TP672,Hipor M,Smart VBHNxxxZA03,VBHNxxxZA04 Fbnesola Vitrus2 Series & 156 Series SC,SC B,SC B1,SC B2 Pei mar SGxxxM (FB/BF) Rsen RSM72-6(MDG)(M),RSM60-6 Tesla TxxxH,TxxxS Phono Solar PS-60,PS-72 SEG Solar SEG-xxx-BMD-HV PA05,PD05,DD05,DE06,DD06,PE06, Prism Solar P72 Series SEG-xxx-BMD-TB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy SN72 & SN60 Series(40mm) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim SEG6& SRP-6 Series UP-MxxxP(-B), Upsol ar OYEAK DUO BLK-G6+ Sharp NU-SA& NU-SCSeries UP-MxxxM(-B) Q.PEAK DUO BLK-G6+/TS SLA, SLG,BC Series &SlLxxx(BL/NL/NT/HL/ D7MxxxH7A,D7(M/K)xxxH8A Q.PEAK DUO(BLK)-G8(+) Silfab M L/B K/N X/N U/H C) United Renewable Energy FAKxxx(C8G/E8G),FAMxxxE7G-BB Q.Cells OYEAK DUO L-G8.3/BFF SoLarever USA SE-166'83-xxxM-120N (URE) FAMxxxE8G(-BB) OYEAK DUO (BLK)ML-G9(+) PowerXT-xxxR-(AC/PD/BD) FBMxxxMFGBB Q.PEAK DUO XL-G9/G9.2/G9.3 Solaria PowerXT-xxxC-PD Eldora, OYEAK DUO(BLK) ML-G10(+) PowerXT-xxxR-PM (AC) Vikram Solivo, OYEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Somera SunmoduLe Protect, OYEAK DUO BLK ML-G10+/t SolarWorld Sunmodule Plus Waaree AC& Adiya Series Alpha (72) (BLack)(Pure) Winaico WST& WSPSeries SS-M-360 to 390 Series, RECkxxAAPU RE-R Yn li YGE& YLMSeries SS-M-390 to 400 Series, 9 RECxxxNP3 BLack Sonali SS-M-440 to 460 Series, ZN Shine ZXM6-72, ZXM6-NH144-166_2094 N-Peak(BLack) RECSoIar SS-M-430 to 460 BiFacial Series, N-Peak 2 (BLack) SS 230-265 PEAK Energy Series SLnEdison PEAK Energy BLK2 Series F-Series,R-Series & FLEX FXS Series PEAK Energy 72 Series • Unless otherwise noted,all modules Listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM DRAWING NUMBER • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information SS i tntertek AUTHORIZATION TO MARK Intertek AUTHORIZATION TO MARK Tots!Otuallty.Assured Total Quality.Assured This authorizes the app1calion of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer / Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc.,Lake Forest,CA Control Number: 5003705 Authorized by: Control Number: 5014989 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C us C US time t,a>lee Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. Tr i Authoruabon Io Mark is for the e„clusvu use of Imeneii s Ckuen and is prov stud pursuant to the Cend,cation agreement cehve�m a+tunra..ind its Client.Inlerluk's ruw: tsibility and liability are Tins Authorization to Mark is for the exclusive use of hntenews Cfnnt and is provided pursuant to the Cerblica,on agreement bolwean Intertek and its Client.Inter[ck's responsibility and liability are limited to the tdrrns and conditions of the apreemenl.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,experise or damage occasioned limlad to Itro teems and wridtlions of the agreement lnlonek assumes no liability to any party,other than to ase Client in accordance with the dgieemont,for any IM expense or darnago occasioned by the use of this Authors:abon to Mark Orly the Client is authorized to permit copying or distribution of this Aulhonzation to Mark and then only in its entirely Use of Inlertek's Certification mark is by the use of this Authorization to Mark Only the Client is authorized to permit copying or distributian of this Authorizaton to l tark and then only in its entirely Use of Inlenek Is Ceroficabon mark is restricted to the conditions Imo out in me agreement and in this Authorzabon to t tsa Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must resirrdied to the conditwas laid out in the agreement and in this Authorization to Mark,Any lutmer use of the Intertek name for the sale or advertisement of the tested material,product or service must fast bs,approvc0 in writing by Intertek initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certif cation mark in accordance with the first be approved in writing by Imon ek Initial Factory Assessmetifs and Follow up Services are for the purpose of assuring apprepnate usage of the Certification mark in accordance with the re not for the purposes a production quality control and do not relieve the Client of their obligations in this respect acreomenl,rises are not for the purposes of production quality control and do not relieve the Client of their obligations in This respect. agreement,they a Intertek Testing Services NA Inc. Intertek Testing Services NA Inc- 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:20201 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 1 of 4 p ED 16,3 15(1-Jul•2022)Mandatary ED 16.3.15(1-Jul-2022)Mandatory DRAWING NUMBER SS BLUE RAVEN Intertek AUTHORIZATION TO MARK Lntertek AUTHORIZATION TO MARK Total Quality.Assured. Total Quality.Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE Address: Address' Albuquerque, NM 87102 Address: Albuquerque, NM 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc.,Lake Forest,CA LW11" Lev Control Number: 5019851 Authorized by: Control Number: 5021866 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder,Certification Manager T - C US C US Uty1c9 Urtyte Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Atrlhorizalion to Mark Is for the exclusrre use of loulnek's Client and is D ovide0 pursuant to the Certification agreemanl between Intertok and its Client.Inlenek's respon-bility and hatnlity are This Authorization to Mark is for the excl"ve use of Inlelef,s Client and is provided pursuant to the Certification agreement betvrten Intertek and Its Clienl.Inlerlek's respcasibility antl liability are hinted to the terms and conditions of tru agreement Intartrk assumes no habhly to any party.other than to the Ghent in accpdance w+ih the agreement,for any loss expanse or damage occasioned lnsle i to the forms and conditions of the agreement.lnlmtek assumes no liability to any party.other than to the Clant In accordance with the agreement.for any loss.expense or damage occasioned by the use of this Authorization to Mark Orly the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirely Use of Inlertek-s Certification mark is ty the use or thin Authorization to Mark Only IM Chant is authorized to permit copying 0r distribution of this Authorization to Mark and then only in its entirety-Use of Inlertek's Certification mark is restricted to the conditions laid out in ilia agreement and in this Authorization to Mark Any further use of the Intertek name for the sale or advertisement of the tested material,product or service nwsl msthcted to the condivorK laid out in the agreement and in this Autnonzation to Mark.Any fuithar use of the Intertek name for the sale cr advertisement of the tested material,product or service must first be approved in writing by Intertek Initial Factory Assessments and Follow up Services are for the purpose a assuring for the appropriate usage r the Ce t of the t mark in accordance t or the first be approved In writing by lnlonek Initial Factory Assossrnsrits and Follow up Services are for the purpose of sssuring appropriate usage of the Cednccalion mark in o rdance with the agreement,they are not for the purposes of production quality control and do not relieve the Client o'their obligations in this respect agreement.they are not for the purposes of productionOnality control and do not relieve the Client of theirobhgobans in Ilia respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories[GSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 3 of 4 p DPAWINo Nuknea3 ED 16 3 15(1-Jul-2022)Mandaloy SS "111�1* ntertek Lntertek Listing Constructional Data Report (CDR) BLUE RAVEN Listing Constructional Data Report (CDR) g Total Quality.Assured. Total Quality.Assured. 1.0 Reference and Address 1.0 Reference and Address Report Number 102393982LAX-002 Ori inal 11-A r-2016 Revised: 5-Oct-2022 Report Number 102393982LAX-002 Original 11 A r 2016 Revised: 5 Oct 2022 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use Email Standard(s) with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020] Applicant Unirac. Inc Manufacturer 2 Address 1411 Broadway Blvd NE Address Albuquerque, NM 87102 COUntry USA Country Contact Klaus Nicolaedis Contact Todd Ganshaw Phone 505-462-2190 Phone 505-843-1418 FAX NA FAX Email klaus.nicolaedis@unirac.com Email toddg@unirac.com Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 5 Address Country Contact Phone FAX Page 1_9f 138 Page 2 of 138 eemerv,between Intertek and its ci,erit Intertek's respoeis W1y and This repon is for the er2luv w.ro use oe tMertek's Client and is provided pursua to the agreemen,between Iniertek and its Client InteneXs respons+bky and This report is for the exclusive use of tntertek's Client and provided pursuant to the age t aty are lirn�ted to the farms and oorvldons oa the agreement tnteftk assumes no lobdrty to any party. other than to the Ghent in a--eordanoe with the tab.ty are kmRod t0 the terms a+d cOnd4ion5 the agreon+ent tmoRak assumes ro Itawtrty to any party other than to the Ctie7 in xcoroance wttti tt+e or distribution of repeat and agreement for any Ions.expense or damage oecasiorfed by fife use of this report Only the Client a authorized to permits copnng or dambullion of flits to xiet and agreement,�r any loss,expense or damage occasioned by Me use of this report Only the Ghent is authorized to permit cingwtg DPA NG NUMBER then only in its embrety Any use of the I,veniek name or one Of its narks for the$ale or a�rertis-went of the tested material. product or service must first be then only nits enbrety Any use of the tntertek name or ono oe its marks for the sat-cc adventsement of tote tested rnatenat. poduct or sinter m`st tfst be approved in vmbrxq by Intertek The observations and test results to this report are relevant only to the sarnpfe tested This report by Itself does not empty that the m approved in tenX �� y Iftlerlek The rl s observations vn under anti reesull in this ��abon t are am only to the sample tested This report by Itself does not imply trial one material product,ad service a or has ever been under an Infertek cert,fieaboei Program ISI `e. Issued: 11-Apr-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-Apr-2016 Report No. 102393982LAX 002 Page 3 of 138 - Report Inc Revised: 5-Oct-2022 Unirac, Inc Revised: bLuE RAvr_i,t Unirac 2.0 Product Description 2.0 Product Description Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Models Unirac SFM Model Similarity NA Brand name Unirac The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to Fuse Rating: 30A photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report.There are no rail Module Orientation: Portrait or Landscape s within this product, whereas the 3" Micro Rail, Floating Splice, and 9"Attached Splice Maximum Module Size: ft2 electrically bond the modules together forming the path to ground. UL2703 Design Load Ratting:ang: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads- 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading with black oxide with a stainless type 300 bonding pin,torqued to 20 ft-lbs, retaining the modules to the bracket.The bonding pin of the Micro Rail when bolted and torqued, penetrate Increased size ML test: the anodized coating of the photovoltaic module frame (at bottom flange)to contact the metal, Maximum Module Size: ft2 creating a bonded connection from module to module. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG 355S2W-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope revision in effect in the jurisdiction in which the project resides. Any local electrical codes must LG395N2W-A5, be adhered in addition to the national electrical codes.The Grounding Lug is secured to the LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. photovoltaic module, torqued in accordance with the installation manual provided in this Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same Certifications, & Increase SFM System UL2703 Module Size: Maximum Module Size: 27.76 ft2 engage cable. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psV3600Pa Uplift Sunpower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5"gap between the bottom of the module and the roof's surface See section 7.0 illustractions# 1, 1 a and 1 b for a complete list of PV modules evaluated with these racking systems Other Ratin s INA WV\WING n.'[J%1 FR ED 16.3.15(1-Jul-2022)Mandatory ED 16.3 15(1-Jul-2022)Mandatory SS CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17601 SAINT ANDREWS CRT Permit#:5761 Parcel#:00809200006300 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:4.1 kW PV Solar Panel Installation on Roof Valuation:25456.00 APPLICANT CONTRACTOR HENRY KEN P/LAURA-LEE R BRS Field Ops,LLC BRS Field Ops,LLC dba Blue Raven Solar 17601 ST ANDREWS CT 1403 N Research Way 1403 N Research Way ARLINGTON,WA 98223 Orem Orem,UT 87097 3854820045 385-482-0045 LIC:604 276 519 EXP:07/31/2024 LIC:BRSFV0820N3 EXP:08/23/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION - PERMIT TYPE: SOLAR INSTALLATION CODE YEAR: 2018 STORIES: 2 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. �X4� 3/1/24 2� "0,�� - 01/29/2024 Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections.Adhere to approved plans.Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 02/28/2024 Building Plan Review $390.96 02/28/2024 Credit Card Service $11.73 02/28/2024 Processing/Technology $25.00 02/28/2024 Building Permit $593.19 02/28/2024 State Surcharge-1 st DU $6.50 02/28/2024 Credit Card Service $18.74 Total Due: $1,046.12 Total Payment: $1,046.12 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Permit#: 5761 Permit Date: 01/05/24 Permit Type: SOLAR INSTALLATION Project Name: Kenneth Henry PV Applicant Name: BRS Field Ops, LLC Applicant Address: 1403 N Research Way Applicant, City, State, Zip: Orem Contact: Carson Campbell Phone: 3854820045 Email: permitting.department@blueravensolar.com Scope of Work: 4.1 kW PV Solar Panel Installation on Roof Valuation: 25456.00 Square Feet: 213 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 03/01/2024 Permit Expires: 08/26/2024 Form Permit Type: SOLAR INSTALLATION Status: EXPIRED Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 17601 SAINT ANDREWS HENRY KEN 100 SINGLE 00809200006300 FAMILY CRT P/LAURA-LEER RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# BRS Field Ops,LLC Carson Campbell 385-482-0045 1403 N Research CONSTRUCTION UBI 604 276 519 dba Blue Raven Solar Way CONTRACTOR BRS Field Ops,LLC Carson Campbell 385-482-0045 1403 N Research CONSTRUCTION L&I BRSFIF0820N3 dba Blue Raven Solar Way CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 01/12/2024 SOLAR INSTALLATION BUILDING Approved Fees Fee Description Notes Amount Building Plan Review Table 4-2 $390.96 Credit Card Service $11.73 Processing/Technology $25.00 Building Permit Table 4-1 $593.19 State Surcharge-1 st DU Residential- 1 st Unit $6.50 Credit Card Service $18.74 Total $1,046.12 Attached Letters Date Letter Description 01/29/2024 Building Permit 01/05/2024 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 01/12/2024 XBP Con£ $390.96 162986626 01/12/2024 BRS Permitting 162986626 Hannah Hardwick $11.73 02/27/2024 XBP Conf: $624.69 166686164 02/27/2024 BRS Permitting 166686164 Hannah Hardwick $18.74 Outstanding Balance $0.00 Notes Date Note Created By: 08/05/2024 Sent final expiration notice. Kristin Foster 07/22/2024 sent expiration Notice Hannah Hardwick 06/21/2024 sent expiration notice Hannah Hardwick 02/28/2024 Emailed the permit for signature Kristin Foster 01/29/2024 sent fees owing.Drafted a permit letter to send once fees are paid.Folder is created and in the Hannah Hardwick pending drawer. 01/11/2024 Need revised valuation to include all labor and materials. Kristin Foster 01/11/2024 Received revised valuation.Pending plan review fee. Kristin Foster 01/10/2024 Received hard copies. Kristin Foster 01/05/2024 Reached out for hard copies and for valuation to include all labor and materials. Kristin Foster Uploaded Files Date File Name 03/01/2024 18788693-20240301 BLD5761 IssuedPermit.pdf 01/29/2024 18330555-20240129 BLDL61 ApprovedPlans.pdf 01/11/2024 18169012-20240105 BLD5761 Application.pdf 01/11/2024 18169010-20240105 BLD5761 EngineerLetter.pdf