Loading...
HomeMy WebLinkAbout17216 51st Ave Ne Ste 110_BLD5806_2026 FIRE ALARM PERMIT APPLICATION Community and Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Type of Permit: ❑ New Installation © System Modification Phased Installation ou Property Address: 17216 51st Ave NE Suite No.: Project Valuation: AAJ Lot#: _ Parcel ID No.: Preferred Contact: O Owner O Applicant ©Contractor Project Description: Tenant improvement project, we are adding notification to meet new layout. Owner Name: Tenant 48 Phone No.: Email Address: Cell No.: Mailing Address: 17216 51 st Ave NE __City:Arlington State: WA Zip: 98223 Applicant Name: Pro-Tech Electric, Inc Phone No.: 425.334.9844 Email Address: Tbentem@pro-techelectric.com Cell No.: Mailing Address: 1126 Bonneville Ave city: Snohomish State: WA Zip: 98290 Contractor Name. Pro-Tech Electric, Inc Phone No.: 425.334.9844 Email Address: Tbentem@pro-techelectric.com Cell No.: Mailing Address: 1126 Bonneville Ave City: Snohomish State: WA Zip: 98290 L&I Contractor License Number: PROTETE934JC Expiration Date: 4/3/2025 SUBMITTAL REQUIREMENTS: Provide Information on AH Equipment to be Installed Prior to Installation Submit electronic files of the follow: 0 Complete and Scaled Plans 0 Specification Sheets 0 Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) **DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch,Supervisory Switches, Magnetic Door Hold-Open Devices,Remote Annunciators,Pull Stations, Beam Detectors,and other such devices. (Each piece is one device) PLAN REVIEW FEES-shall be paid at time of application submittal Less than$5,000.00=$100.00 $5,000.00&over-based on project valuation (Plan Review Fee is 6S%of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application -review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 ✓❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $300.00 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $375.00 ❑ NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $ PERMIT FEE TOTAL $375.00 PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $400.00 1 hereby certify that I am the ❑Owner, ✓❑Applicant, ❑Contractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Taylor Bentem 2.6.2024 Signature Print Name Date SAVE PRINT REV202Z Page 2 of 2 FIRE SYSTEM O. SILENT Model 5495 Distributed Power Module KNIGHT In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sensor@,GenteA AMSECO®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control Stand alone operation /Communicator. The 5495 is the cost- Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern, which can upgrade older control panels that lack cadence ANSI Cadence pattern output capability. capability built-in Features Connection to Local Fire Control • UL Listed for 6 amps of notification The 5495 may be connected to a local Model 5495 fire control which utilizes Class A or power Class B type notification circuits Distributed Power Module • Power supply's advanced switch operating between 9 and 32 VDC.The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the • UL Listed more efficiently than other systems 5495. The control panel's notification • MEA 429-92-E Vol XI • Dip switches allow for easy circuit end-of-line resistor is also . CSFM 7300-0559:123 reconfiguration connected across two terminals on the . NFPA 72 • 24 VDC filtered output voltage 5495, which provides supervision • Four power-limited notification between the 5495 and the fire control OSHPD (CA)OSP-0065-10 outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual (see accessories) Class A and 2 Class B notification devices are then connected • Additional continuous auxiliary to the 5495 signal circuits using the output 4.7kf2 end-of-line resistors provided. Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs; 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the control panel. FIRE SYSTEM O. Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32' to 120' F • Earth ground fault Notification (0' to 49' C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 kf2 EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification Accessories: AC input: 120 VAC at 2 amps No. of inputs 2 p p Input SK-SCK Seismic Compliance Kit Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350395 Rev F subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800)328-0103, Fax: (203)484-7118.For Technical Support, please call 800-446-6444. www.silentknight.com - ------ ---------- ------ - r- ------ ---------- ------ -� r- ------ ---------- ------ - I 1z O O O O O O C OFFICE 102 A OFFICE SERVER _ OFFICE ,5 IS e O O 5 O O O A ao O A O C. To Auxiliary Power A Supply _—-—_�-, BREAK _-— us ' UNISEX �� UNISEX i 104 :J-- �—_�`, 107 ______ 15 ll`_u A WARE20 E A - " A «, �n To Auxiliary Power Supply I S . S r,, , , „5 n5 I _---_ - _______________________________________ _____ ___ I I I I I I I I I I A LU Z N A Q) CV O O > O O O O O - - - - - - - ------- - - - - - -- -- - - - - - - - -- - - - - - - - - --------- - - - - - - - - �""' > Q A i Q cz N r p Cn LO �--' ti Q T 115 O O o f I I I O - 113 L--------------� I I I I I I I I I I I I I I I I A A O O A I I I I I Revisions Revision# Date 115 115 115 - O A -________--_____ ____________I_ l l REMOVE EXISTING DRIVE IN DOORS, REMOVE EXISTING EXIT LIGHT. PROVIDE TRACKS, MAN DOORS, TUBE STEEL JAMBS, Designed by.Harold Befus AND TRANSOMS. JUNCTION BOX IN CASE OPENING Fire Alarm Systems NICET Level IV RESTORED IN THE FUTURE. cart. ttosts,Exp.3/1/2025 REMOVE EXIS ING OVERHEAD VEIFFIMISTING DOCK DOOR, TRACK, AND LEEM EMOVE EXISTING OVE AD DOORS, PROVIDE 3—POINT LOCKING OPENING AND INSTALL NEW INDC C90B1UMPERS. OLUMNS AND MAN OORS. SAWCUT HARDWARE WITH MEDICO Drawn By: HOLLOW METAL MAN DOOR WITH XISTING CONCR PANEL HEADER TO MEDIUM SECURITY LOCK AT PREFABRICATED EXTERIOR STEEL STAIR. LLOW INSTAL ION OF NEW INSULATED THIS LOCATION. REMOVE Scale: 1/8"=1' RELOCATE EXIT R To' WI x 16'-0" HIGH OVERHEAD EXTERIOR HARDWARE, SIGN. NOORS. DOOR TO BE USED FOR Page No. FA-1 EGRESS ONLY.— Date:1/31/2024 p II>rrr�e Auxilary Power Supply Battery,Voltage Drop Calculations W M Standby z Project: Current Alarm Current M rNv� Model: Silent Knight 5495 0.075 0 W W Voltage drop calculations based on 14 gauge wire,starting voltage 20.4 Length of circuit Voltage at }� Q Device Description Current Draw one way end of line%Voltage drop i j NAC I-Qty < 0 1 0 Cz M —r 0 0 a) Device Schedule 0 0 � T O nre N.--ed P-1 0 0 � �/31 ciliary Power swoly O 0 0 CO Total NAC 1 Existing Load 1.5 300 17.529 14.07 T — © Maaaal PO slaraa N ® ty PmtoeMmm S.-IM<dor _ NAC 2-D Q Imo o<mno. oQ m Hex�ro. 0 0 0 0 0 sgdaki=wax<reow s.�mn 0 0 Q SPnnkkr—,e,valve—1, 0 0 ® sPdakM.a.Prcssarc s.dm 0 naa,<ssank Maaaa.Maam< Total NAC 2 Existing Load 1.51 320 17.3376 15.01 o m,dank h.1 Mamm.lh-e ❑ "emos—caro m kada< n NAC 3-Q ty 0 "d-01,Racy Mma< 3lSystem Sensor PC2L-115 0.187 0.561 d❑ Quad=amen Mom,«/Body Maaale •^„ 4lSystem Sensor SCL-115 0.158 0.632 ® ca�r<auaaai zoos Mmw< ns" ns" ,Is" us '' " ns" ns 112,2tem Sensor PC2L-75 0.143 0.143 1 Systern Sensor PC2L-30 0.09 0.09 0 51SYstem Sensor SL-15 ca 0,043 0.215 Ceiling Strobe.Candela as MaM1edIIS" 11 " 115" 113 O 0 HY wall shoes camera as M.— Total NAC 3 1.641 400 16.21217 20.53 a cedmg Ham ff-11 s'°ppy NAC4-Qty uw Ham 4System Sensor PC2L-115 0.1871 0.748 3 System Sensor SCL-115 0.158 0.474 _ 0 0 cdimq Sp ker�� O O This project is a tenant improvement in an existing warehouse 0 0 Ipj wall sE ak<. wi,e Table building. The building is fully sprinkled. We are adding notification to 0 0 Desig,aeo, D—Epee, meet the new layout. We are not adding any initiation. There is an Total NAC 4 a ie 2ITL existing Auxiliary Power Supply that we will use to power the new 1.222 450 16.89164 720 B EI«tric Ben .m e c 16 2 FPL notification. Revisions D 14 2 FPL Shieldee Auxiliary Power Draw p Moga =ma.Hom<. E memee Revision# Date F 18 2 FPL Shielded Ph..dock AR 14 L Total Power Draw 0.075 5.863 BR 6 2 FPLR va=,rra=�auao Pun<� CR , L 24 or 60 hrs. DR 14 2 FPLR Shielded m.Frcqu<n=y saaea<, <.,. ER 1 L memee Standby Power AH Required 24 1.8 FR 18 2 FPLR Shielded "r 14 L 5 or 10 min BP 16 2 FPLP Alarm Power AH Required 5 0.49 CP FPLP DP 14 2 FPLP Shielded EP 1 L Melded TotalRequired FP 18 z FPLP smelled Total Requred+20% 2,75 G 14 HHN H z- i6 TFFN Battery Required 3 Battery Supplied 7 Designed by Harold Befus Fire Alarm Systems NICET Level IV Cert. $110615, Exp. 3/l/2025 Drawn By: Scale: 1/8"=1' Page No. FA-2 Date:1/31/2024 SYSTEM SENSOR° Indoor Selectable- Output Strobes and 4*� Horn Strobes for Ceiling Applications f System Sensor L-Series audible visible notification r products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & F M X APPROVED LISTED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 AVDS868-02•12/01/2017•Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) 6.92"diam. 2.5' 6 diam. (175.77 mm) (64 mm (17 )� (173 mm) a•\a*r.rMr o TR O rn 0 o CDo 0 o 00 O O o Q o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box ® ( a 0 PA\NT OOO�o®mmm o0�0� O oOpem®0 00 • ® o�n — opu° / pp ppp °$o poo �000 • �°0000 0 � ovo A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM ©t to c System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR" Phone:800-SENSOR2•Fax:630-377-6495 or current product information,6,-02ng the latestversion ofthis data sheet. AVDS868-02•12/01/2017 „F ,-.xr. .v, a vx ,. .. ':”- = _-.. .-_...- r. _ .�:v vvv Jrvl� /. !' r.%^..n,<.. -. - "qrx ..n-JPfv_u ... .--,..-___ h, '. .,".."..,."". ,".-..ate... _ :..:::v ..."...";, ..,".> 'a' t I ��.ERVFR is � tr .., r '��• �,.� ca 1 1 1�='.+���_ .TT Tt� lw� 75 0. 150® ,. r To Auxiliary ry Power Supply 's! -- _JL — I'r , r Q$ A -_—. t1,nrz.a-_ l 20� .. i((� II E k� yyl3 s �,�.... g I A ! I ` A Chi ! ( I i �I To Auxiliary Power 0 j ) re A supply � ..1 `u ( t. I j ' ns J ns i A CO cmA i A 4�d I jE { p ! �E (� !I ®� tI Its t�J I " tts I tts 4'j ! i j II I I I NGT CITY ARIJ �LDNG DEEATT RP E TON € APPROVED. ` DATE`���`t�`�E I � No cr,a.Nc es a-rno;zlzeo i UNLrSS APPrO�FD a,NE j sulLolN;NGFECTOR " rpr i $ A et A J I J J J J gq IVED I A ' FEB 0 6 2026 � I I I I [ IRevisions � i I � � Revlsian# i Daft, -------------------------------- I 115 � . i. E. x IN --- —I _. K " t EXISIINS k LI NT_ -ON BOX ti �,� 0�'E +E' Designed by.Harold Befus I Fire Alarm Systems NICET Level IV j j I AND TRANSOMS. I r E'D IN THE RE Cert.#110615,Exp.3/1/2025 REMOVE EXIS ING OVERHEAD VINE iSTING DOCK DOOR, TRACK, AN l j REMOVE EXI "`^v _I' ; AC PROVIDE �. P !°J ICK(,"i0 I OPENING AND,INSTALL NEW IN9(} ED1MPERS.--7 PARDINARE WjTH I DCC j HOLLOW MSi, MAN DOOR WITH i X ��� t 0 t EM 3 URIC 'LOCK AT --- { II PRE FAE3RIOA,TE EXTERIOR STEEL STAIR.— 1 A NEW n E c t n iti RPMG'VE �I - RELOCATE EXIT _-� E E To x H 7. D 1 ''e E�lGFA E SIGN. S. i!S-n �� r x„ OR !I i t I� — L� r i i Auxilary Power Supply Battery,Voltage Drop Calculations W Standby co r Z V Project: _ Current Alarm Current C (3) N Model: Silent Kni hk 5495 _ 0.075 0 Voltage drop calculations based 14 gauge �}. � M wire,starting voltage 20.4.4 �J Length of circuit Voltage at w�W�t}� C V (1) < Device Description Current Draw one way end of line%Voltage drop (-) > NAc _oty C i < D a _—. �—a C Device Schedule _ t1 D - ---- -...... CU Cn n o o0 aMP Rm Norm GntM Parts w-n..M —1la v Powp saaeN a Q Maanalmor "We':.•, Total NAC 1 Existing Load --_ — 1.5 3070 17.529 14,07 T ,w. Q Manuol Pull R.MM — ® R.I.be&s Detaamr ,q;�„°°},°-,g' NAC 2-Qty --- _ ® cad DR .r ....................__...__.., 0 o T� 0 0 Q ha,n Debamr _.-- _a 0 O SpHMder Waaarah.Swlkx ' —.--- •-0 a Qm SpMbar Tamper Valve S r h 0 0 SpnaMer Nr P...S,Iah 0 W� Iddeaable Manila Mndul. ..w w W+',e. Total NAC 2 Existing Load _ 1 b 320 17,3376 15.01 O Ntlmnble Dual Monitor Modub .+,wrP+',+, � banewm.cono-ol Madm. w�w•tir,r INAC3-Qty ' y laabb Relay.ada, M„w„+,,. stem Sensor PC21-115 0 187 0.561 0 aaae aambo Mmlla/RMq M.dal. w.r.r.,vlr, n+System Sensor SCL 115 0_158 -0.632 1 System Sensor PC2L-7.5 -_ 0.143{f _.-0.1,43 —..._ —— ........ ._.. .. 1 ,.-.......... ._.. ..__. O, ® Gmwnonal zone Notlul. w w r ew•r I 1. Q U'HN Stadub �...,..w,l. - — -- ..._. .. - I�' CITY OF ARLIN(+TON 1 System Sensor F'CLL 30 0 09 0 09 G1011g Slrabe.GmiNo a.MaHMtl eyy"�T y- I I I I e a S 8 IS 3X wag M,aba,G la ae Wrk d ^ -• Total NAC 3 5 S stem Sensor SL-15 cn 0,043 0 645!l aoo 16,21217 2063, euuDlNcUr:F'ARrMr_Nr � GHag Horn e..MM,eA Maw^�+-+•�� �q ----' APPROVED Wall Ham ,a.-.,m NAC a-calms ads seem yin r7 ct 1 i _ __ — o se ---.- ---o,4i4 I� Mml Ham `:y:., System Sensor PC2L 11 0 187 __ 0.748 .ere lwa sow..c,a,M w wnr w,ie•'ww°e s i� .-Yr,Z&[, Hain wve,.0 ru"x.e a�c'+a" ..— ___-.__......-_. _— NO C'HANGC A11�'VyTZ F 0 p UNIT'^APA�IJ aY THE route eyy^�e Wire Table building. The building is fully sprinkled. We are adding notification to _— ..� � - of .y 1—__00� eul c!Nc1NSPecroR Ell GaN sww This project is a tenant improvement in an existing warehouse i IpM Wall Speobw �yy Glq sgol-SIW.OmMM .,,,,,, Deelgmfl.P D—ripuan meet a new layout We are not adding any initiation. There Is an Total NAC4 - - tzz2 aso 16,89164 17.20 WMle,w a.,aw.brM,wa •�,•',� s existing Auxiliary Power Supply that we will use to power the new s &II „,w,, w notification. ,<< Auxiliary Power Draw Revisions ® Magaeaa Da"Haver "'"�?°aer"x,r u" e e Revision# Date Qm nmman'.Phone Ad :',;'M'"n Total Power Draw 0.075 5863 e+,c vane Fwaacan Par,l a lee 24 or 60 his. w.Fr .,sound., �iwawP+', Standby Power AH Required 24 1.8 F � 5 or 10 min Narm Puwcr AH Required 5 0.49 1111 Total AH Required 2.29 e< Total Requred^20% 2.75 Battery Required 3 Battery Supplied Designed by Harold Befus Fire Alarm Systems NICET Level IV Cert.#110615, Exp. 3/1/2025 Drawn By: Scale: 1/8'1=1' Page No. FA-2 Date:1/31/2024 Permit#: 5806 Permit Date: 02/07/24 Permit Type: FIRE ALARM Project Name: Tenant 48 Applicant Name: Pro-Tech Electric, Inc. Applicant Address: 1126 Bonneville Ave Applicant, City, State, Zip: Snohomish,WA 98290 Contact: Taylor Bentem Phone: 425-334-9844 Email: tbentem@pro-techelectric.com Scope of Work: Adding notification to meet layout for a new tenant improvement Valuation: 6500.00 Square Feet: 37632 Number of Stories: 1 Construction Type: 111B Occupancy Group: S-1; Storage Mod Hazard ID Code: CIC Permit Issued: Permit Expires: Form Permit Type: FIRE ALARM Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP 31052100400100 17216 51 ST AVE NE STE ARLINGTON 090 MASTER 110 AIRPORT ADDRESS INDUSTRIAL PA Contractors Contractor Primary Contact Phone Address Contractor Type License License# CONSTRUCTION L&I HIGHPCP783M1 High Caliber plumbing Emily CONTRACTOR Pro-Tech Electric,Inc Taylor Bentem 1126 Bonneville CONSTRUCTION L&I PROTETE934JC 425-334-9844 Ave CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 02/07/2024 FIRE ALARM BUILDING In Review Fees Fee Description Notes Amount Fire System Plan Review Table 4-2 $129.15 Total $129.15 Payments Date Paid By Description Payment Type Accepted By Amount 02/07/2024 XBP Conf: 165043886 $129.15 Outstanding Balance $0.00 Notes Date Note Created By: 02/07/2024 Contractor needs COA endorsement prior to issuance.Emailed the info. Kristin Foster Uploaded Files Date File Name 02/07/2024 18480217-20240206 BLD5806 Plans.pdf 02/07/2024 18480218-20240206 BLD5806 SensorSpecs.pdf 02/07/2024 18480219-20240206 BLD5806 Application.pdf 02/07/2024 18480220-20240206 BLD5806 DataShect.pdf CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17216 51ST AVE NE STE 110 Permit#:5806 Parcel#:31052100400100 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Adding notification to meet layout for a new tenant improvement Valuation:6500.00 OWNER APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT Pro-Tech Electric,Inc. Pro-Tech Electric,Inc INDUSTRIAL PA 8201 164TH AVE NE STE 110 1126 Bonneville Ave 1126 Bonneville Ave REDMOND,WA 98052 Snohomish,WA 98290 Snohomish,WA 98290 425-334-9844 425-334-9844 LIC:602 694 961 EXP:02I1 O25 UC:PROTETE934JC M:04/03/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2018 STORIES: 1 CONST.TYPE: llIB DWELLING UNITS: OCC GROUP: S-1;Storage Mod Hazard BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete infornation,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 02/29/2024 Applicant Signature Date Building Official Date CONDITIONS Adhere to the approved plans.Approved job copy shall be onsite for inspections.Call for inspections. The property owner shall ensure that the construction project complies with an applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/01/2024 Fire System Plan Review $129.15 03/01/2024 Credit Card Service $3.87 03/01/2024 Processing/Technology $25.00 03/01/2024 Fire Alarm System Permit $300.00 03/01/2024 Credit Card Service $9.75 Total Due: $467.77 Total Payment: $467.77 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 5806 Permit Date: 02/07/24 Permit Type: FIRE ALARM Project Name: Tenant 48 Applicant Name: Pro-Tech Electric, Inc. Applicant Address: 1126 Bonneville Ave Applicant, City, State, Zip: Snohomish,WA 98290 Contact: Taylor Bentem Phone: 425-334-9844 Email: tbentem@pro-techelectric.com Scope of Work: Adding notification to meet layout for a new tenant improvement Valuation: 6500.00 Square Feet: 37632 Number of Stories: 1 Construction Type: 11113 Occupancy Group: S-1; Storage Mod Hazard ID Code: CIC Permit Issued: 03/01/2024 Permit Expires: 08/28/2024 Form Permit Type: FIRE ALARM Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP 31052100400100 17216 51 STAVE NE STE ARLINGTON 090 MASTER 110 AIRPORT ADDRESS INDUSTRIAL PA Contractors Contractor Primary Contact Phone Address Contractor Type License License# Pro-Tech Electric,Inc Taylor Bentem 425-334-9844 1126 Bonneville CONSTRUCTION COA 602 694 961 Ave CONTRACTOR Pro-Tech Electric,Inc Taylor Bentem 425-334-9844 1126 Bonneville CONSTRUCTION L&I PROTETE934JC Ave CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FA00.FIRE ALARM lam**time approved by 03/07/2024 FINAL KO and additional fees have 03/11/2024 03/11/2024 BUILDING Approved been paid Plan Reviews Date Review Type Description Assigned To Review Status 02/07/2024 FIRE ALARM BUILDING Approved Fees Fee Description Notes Amount Fire System Plan Review Table 4-2 $129.15 Credit Card Service $3.87 Processing/Technology $25.00 Fire Alarm System Permit NFPA 72- 105.7.3 $300.00 Credit Card Service $9.75 Inspection Inspection outside of $150.00 business hours. Credit Card Service $4.50 Total $622.27 Attached Letters Date Letter Description 02/29/2024 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 02/07/2024 XBP Con£ $129.15 165043886 02/07/2024 Nick Dammann 165043886 $3.87 02/29/2024 XBP Conf: $325.00 166886781 02/29/2024 Nick Dammann 166886781 $9.75 03/07/2024 XBP Con£ $150.00 167393460 03/07/2024 Nick Dammann 167393460 $4.50 Outstanding Balance $0.00 Notes Date Note Created By: 03/01/2024 Emailed the permit for signature. Kristin Foster 02/27/2024 Contractor has COA endorsement. Kristin Foster 02/07/2024 Contractor needs COA endorsement prior to issuance.Emailed the info. Kristin Foster Uploaded Files Date File Name 03/07/2024 18853301-20240301 BLD5806 IssuedPermit.pdf 03/07/2024 18853279-20240227 BLD5806 ApnrovedPlans.pdf 02/07/2024 18480218-20240206 BLD5806 SensorSpecs.pdf 02/07/2024 18480219-20240206 BLD5806 Application.pdf 02/07/2024 18480220-20240206 BLD5806 DataSheet.pdf i FIRE ALARM SYSTEM ACCEPTANCE TEST CHECKLIST Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Phone(360)403-3551 Property Address: Permit#: Master Permit#: This document's intent is to provide contractors with guidelines outlining the expectations and procedures for how the City of Arlington will conduct an acceptance test of a fire alarm system. This document addresses the most common aspects of a fire alarm acceptance tests, in cases where this document does not address a device or operation used with your system IFC, NFPA,and/or Manufacturer Specifications will be used to determine testing criteria. STEP 1: PREPERATION Date Initial 1. SCHEDULING-The contractor shall schedule the inspection by calling PASS FAIL N/A the inspection request line(360-403-3417)at least 48 hours prior to ❑ ❑ ❑ the expected inspection.Inspections are conducted Monday-Friday. • Schedule Inspection-The contractor shall schedule for the inspection through the Stanwood/Arlington inspection line. IMPORTANT-the Fire Alarm System cannot be finalized until the associated electrical permit has been finalized. 2. APPROVED PLANS-Approved/Stamped plans on site showing how the PASS FAIL N/A system was installed. ❑ ❑ ❑ 3. CUT SHEETS-Manufacturer cut sheets indicating the proper method of PASS FAIL N/A testing for smoke and heat detectors. ❑ ❑ ❑ 4. PRETEST-Printout of pretest showing all devices have been tested and PASS FAIL N/A how each device annunciates at the FACP. ❑ ❑ ❑ S. NFPA 72 REPORT-NFPA 72 Record of Completion{not required for PASS FAIL N/A flow/tamper systems). ❑ ❑ ❑ 6. 24-HOUR BATTERY TEST-At the time of the inspection/test provide PASS FAIL N/A proof verifying that the panel has been operating on secondary power ❑ ❑ ❑ {battery}for 24-hours.No other problems shall be indicated on the panel. TOOLS EQUIPMENT AND PERSONNEL 7. STAFFING-A minimum of two fire alarm contractors with 2 two-way PASS FAIL N/A radios. ❑ ❑ ❑ 8. CONTRACTORS-The following contractors may need to be present PASS FAIL N/A during the acceptance test depending on the systems provided in the ❑ ❑ ❑ building:sprinkler contractor,mechanical contractor,elevator contractor,general contractor,special suppression system contractor. 9. LADDER-A ladder shall be provided to gain access to devices for PASS FAIL N/A testing. ❑ ❑ ❑ 10. SMOKE/AEROSOL TESTER-Smoke detectors will be tested in place PASS FAIL N/A using a Smoke Detector Tester Aerosol Dispenser with Telescoping ❑ ❑ ❑ Pole to ensure smoke entry into the sensing chamber and an alarm response.No magnets will be allowed. Page 1 of 8 REV03.2022 11. LAPTOP-Laptop with appropriate software to make program changes PASS FAIL N/A if necessary. ❑ ❑ ❑ 12. MANUFACTURER'S TESTING-Any equipment required by the PASS FAIL N/A manufacturer's published testing instructions. ❑ ❑ ❑ NOTIFICATION OF TESTING 13. OCCUPANTS-All building occupants shall be notified of the test. PASS FAIL N/A ❑ ❑ ❑ 14. MONITORING COMPANY-Monitoring Company shall place the PASS FAIL N/A system(s)in"TEST". ❑ ❑ ❑ 15. VERIFY INFORMATION-Verify that the monitoring company has a PASS FAIL N/A valid address,proper business name,and the correct number for ❑ ❑ ❑ Snohomish County 911 (425-407-3970). STEP 2: SIGNAGE AND MARKINGS low- Date Initial 1. FACP ROOM-An approved sign shall be posted on the door to the PASS FAIL N/A room containing the FACP.The sign shall be constructed of durable ❑ ❑ ❑ materials,permanently installed,readily visible,and have a red background and white lettering that reads"FIRE ALARM CONTROL PANEL INSIDE"or"FIRE ALARM ROOM"or"FACP ROOM"or similar language. 2. CONTACT INFORMATION-An approved sign shall be posted at the PASS FAIL N/A control panel and states the name of the monitoring company and the ❑ ❑ ❑ 24-hour phone number of the Central Station.It shall also state that the Central Station shall be called before doing any work or testing on any system being monitored. 3. INSTRUCTIONS-Reset instructions and reset code shall be clearly PASS FAIL N/A posted at the FACP. ❑ ❑ ❑ 4. FLOOR PLAN-A laminated floor plan(11"x17"minimum)for each PASS FAIL N/A building floor shall be posted adjacent to the FACP in the Fire Control ❑ ❑ ❑ Room.It shall indicate the location of all initiating devices,inspector's test valve,monitored valves and main corridors,stairwells,and elevators. S. DEDICATED CIRCUIT-The fire alarm control panel shall be on its own PASS FAIL N/A dedicated circuit that is labeled FACP,red in color,and locked in the ON ❑ ❑ ❑ position. 6. J-BOXES-It is required that all fire alarm 1-boxes are painted red or PASS FAIL N/A labeled FIRE ALARM. ❑ ❑ ❑ 7. DOCUMENTATION CABINET-A documentation cabinet labeled PASS FAIL N/A "SYSTEM RECORD DOCUMENTS"shall be installed at the system ❑ ❑ ❑ control unit or at another approved location accessible only to authorized personnel. STEP 3: MAXIMUM LOAD TEST—SECONDARY POWER Date Initial 1. MANUAL FIRE ALARM BOX-While on battery power,initiate an PASS FAIL N/A Alarm by pulling the manual fire alarm box located at the FACP. ❑ ❑ ❑ 2. 90 SECOND ALARM SIGNAL-Verify that the remote Central Station PASS FAIL N/A has received a fire alarm signal within ninety(90}seconds.Let alarm ❑ ❑ ❑ continue during next step. Page 2 of 8 v1.2023 3. S-1S MINUTE TEST-Let alarm continue for a minimum of 5 minutes PASS FAIL N/A for general occupant notification and 15 minutes for voice Evacuation. ❑ ❑ ❑ This will give enough time to verify operation of all notification devices throughout the facility. AUDIBLEALARM NOTIFICATION DEVICES 4. PER PLANS-Verify annunciators are installed per approved plans PASS FAIL N/A ❑ ❑ ❑ S. AUDIBLE SOUND-Audible alarms devices must be 15 dBA above PASS FAIL N/A normal ambient sound level in all occupiable areas of building. ❑ ❑ ❑ 6. SIGNAL PATTERN-Audible signal pattern used to notify building PASS FAIL N/A occupants of the need to evacuate shall be the standard alarm ❑ ❑ ❑ evacuation signal consisting of a three-pulse temporal pattern. 7. MOUNTING-Wall-mounted appliances shall have their tops above the PASS FAIL N/A finished floor at heights of not less than 90-inches and below the ❑ ❑ ❑ finished ceilings at distances of not less than 6-inches.Ceiling-mounted or recessed devices shall be permitted. 8. COMBINATION AUDIBLE/VISIBLE-Combination audible/visible PASS FAIL N/A appliances shall be installed as per the requirements for a visible alarm ❑ ❑ ❑ notification appliance. 9. ENVIRONMENT-Verify that all appliances as listed for the PASS FAIL N/A environment that they are located.(walk-in coolers/freezers,etc.) ❑ ❑ ❑ 10. GUARDS/COVER/LENSES-Devices subject to mechanical damage PASS FAIL N/A shall be suitably protected by a guard,cover,or lenses that is listed for ❑ use with the device. VISIBLE ALARM NOTIFICATION DEVICES 11. PER PLANS-Ensure the cd matches what was indicated on the plans. PASS FAIL N/A ❑ ❑ ❑ 12. FLASHING NOTIFICATIONS-Indoor strobes must flash 60-120 times PASS FAIL N/A per minute and in spaces such as corridors where more than two visible notification devices are in any field of view,they shall flash in synchronization. 13. LIGHTS-Lights used for fire alarm signaling only or to signal the intent PASS FAIL N/A for complete evacuation shall be clear or nominal white. ❑ ❑ ❑ 14. WALL MOUNT-Wall-mounted devices shall be mounted such that the PASS FAIL N/A entire lens is not less than 80-inches and not greater than 96-inches ❑ ❑ ❑ above the finished floor. 15. CEILING MOUNT-Ceiling-mounted devices shall be permitted.If PASS FAIL N/A ceiling heights exceed 30-feet,ceiling-mounted visible notification ❑ ❑ ❑ devices shall be suspended at or below 30-feet or at the mounting height of a wall mounted visible notification devices. 16. ENVIRONMENT-Verify that all appliances as listed for the PASS FAIL N/A environment that they are located. (walk-in coolers/freezers,etc.) ❑ ❑ ❑ STEP 4: POWER SUPPLIES AND TROUBLE SIGNALS Date Initial 1. RESET-Once all notification devices have been verified and the PASS FAIL N/A minimum alarm time has elapsed,silence the signal,and ensure horns and strobes cease. Page 3 of 8 v1.2023 2. CLEAR PANEL-Have primary power turned back on and verify that PASS FAIL N/A the panel has been cleared. ❑ ❑ ❑ 3. BATTERY LEAD-Unplug one battery lead,the panel shall indicate a PASS FAIL N/A trouble within 200 seconds. ❑ ❑ ❑ 4. BATTERY DATE-Also,ensure the battery manufacture date is written PASS FAIL N/A on the batteries. ❑ ❑ ❑ 5. BATTERY SIZE-Compare the calculated size of batteries in submittal PASS FAIL N/A to actual batteries installed. ❑ ❑ ❑ 6. GROUND FAULT-Have the installer create a ground fault on the PASS FAIL N/A system,to ensure that the trouble condition and ground fault is ❑ ❑ ❑ annunciated on the FACP. 7. DACT-Have the alarm technician disconnect the primary line from the PASS FAIL N/A DACT to confirm a trouble signal on-site and transmission of a trouble ❑ ❑ ❑ signal to the supervision station within 4-minutes.Repeat this process with the secondary line. 8. NOTIFICATION APPLIANCE-Remove a wire from a notification PASS FAIL N/A device.The system shall go into trouble at the FACP within 200 ❑ ❑ ❑ seconds. 9. SMOKE DETECTOR-Remove a smoke detector from its base and PASS FAIL N/A ensure a trouble is shown on the panel within 200 seconds. ❑ ❑ ❑ 10. REMOTE ANNUNCIATOR-If a remote alarm annunciator is provided, PASS FAIL N/A verify operations and that the correct information is being received. ❑ ❑ ❑ STEP 5: FIRE SUPPRESSION SYSTEMS J Date Initial FIRE SPRINKLER SYSTEMS 1. CONTRACTORS-All sprinkler devices shall be tested with both the PASS FAIL N/A sprinkler and fire alarm contractors present. ❑ ❑ ❑ 2. FLOW TEST-Test waterflow alarm by flowing water from the PASS FAIL N/A Inspectors Test Valve.The alarm should sound no earlier than 20 ❑ ❑ ❑ seconds and no later than 90 seconds.(Wet and dry systems) 3. DRY-TYPE SPRINKLER SYSTEMS-Have constrictor demonstrate that PASS FAIL N/A both high and low air pressure are supervised as required.The off- ❑ ❑ ❑ normal signal shall be initiated when the pressure increases or decreases by 10psi. 4. EXTERIOR HORN/STROBE -Verify that a listed horn/strobe device is PASS FAIL N/A located on the front exterior of the building in an approved location near the buildings address.Such device shall be activated by water flow actuation of the automatic sprinkler system. S. CONTROL VALVES-Close all electrically supervised sprinkler control PASS FAIL N/A valves to verify supervisory alarm at the FACP within 2 turns of control ❑ ❑ ❑ wheel or,for Post Indicator Valve(PIV)within 1/5 of valve control mechanism's travel distance.Then reopen to verify"restore"signal. FIRE PUMP 6. PUMP RUNNING-Verify that when the fire pump is running that the PASS FAIL N/A fire alarm goes into alarm. ❑ ❑ ❑ 7. CONTROL VALVES-Close all electrically supervised fire pump control PASS FAIL N/A valves to verify supervisory signal at the FACP. ❑ ❑ ❑ Page 4 of 8 v1.2023 OTHER SUPPRESSION SYSTEMS 8. TYPE 1 COMMERCIAL KITCHEN SYSTEM-Shall initiate an alarm PASS FAIL N/A signal by alarm initiating devices installed in accordance with their ❑ ❑ ❑ individual listings. 9. PRE-ACTION SUPPRESSION SYSTEM-If installed and if it has an PASS FAIL N/A independent control panel it will require a separate NFPA 72 certificate ❑ ❑ ❑ from the building FACP. 10. CLEAN AGENT SUPPRESSION SYSTEM- If installed and if it has an PASS FAIL N/A independent control panel it will require a separate NFPA 72 certificate ❑ ❑ ❑ from the building FACP. STEP 6: ELEVATORS11 Date Initial 1. ELEVATOR TECHNICIAN-Elevator technician must be on site for the PASS FAIL N/A following test to take place. ❑ ❑ ❑ 2. FACP-Actuation from the elevator hoistway,elevator machine room, PASS FAIL N/A elevator machinery space,elevator control space,or elevator control ❑ ❑ ❑ room smoke detectors,or other automatic fire detection shall cause a separate and distinct visible annunciation at the building FACP and remote annunciators to alert fire fighters that the elevators are no longer safe to use. 3. RECALL-Test detector(s)located at elevator lobby that will initiate PASS FAIL N/A elevator recall. ❑ ❑ ❑ (Elevator lobby detectors must be within 21 feet of each elevator door.) • Verify recall to a primary floor • Verify recall to alternate floor • Verify illumination of"Fire Hat" 4. MACHINE ROOM DETECTOR-Test detector(s) located in shaft and PASS FAIL N/A elevator machine room: ❑ ❑ ❑ • Verify recall to designated floor • Verify flashing illumination of"Fire Hat" S. HEAT DETECTORS-Heat Detectors installed in a shaft or machine PASS FAIL N/A room and used for shunt trip(shut down elevator power)activation ❑ ❑ ❑ shall be located within 2 feet of each sprinkler head and have both a lower temperature rating and a higher sensitivity as compared to the sprinkler. STEP 7: INITIATION DEVICES Date Initial 1. FACP-Test individual devices to ensure proper operations and PASS FAIL N/A annunciation at the panel with the correct device location. ❑ ❑ ❑ SMOKE DETECTORS 2. SAMPLE TEST-The fire inspector will select a sample of Smoke PASS FAIL N/A Detectors at random to be tested by using smoke or a listed aerosol. ❑ ❑ ❑ (Minimum of one per floor and no less than 10%of the devises shall be tested). 3. TROUBLE-The fire inspector will select a minimum of one smoke PASS FAIL N/A detector at random to be disconnected to verify a trouble signal is ❑ ❑ ❑ received at the FACP. 4. ADDRESSABLE-All smoke detectors areaddressable models. PASS FAIL N/A ❑ ❑ ❑ Page 5 of 8 v1.2023 S. WALL MOUNT-Wall-mounted smoke detectors must be installed PASS FAIL N/A between 4 and 12 inches from the ceiling measured to the nearest edge ❑ ❑ ❑ of the detector. 6. CEILING MOUNT-Ceiling mounted smoke detectors shall be at least 4 PASS FAIL N/A inches from a wall or ceiling obstruction. ❑ ❑ ❑ 7. SUPPLY/RETURN AIR DIFFUSER-Smoke detectors shall not be PASS FAIL N/A located within 3 feet of a supply or return air diffuser,nor in a strong air ❑ ❑ ❑ stream from a supply diffuser at any distance. 8. LISTINGS-All smoke detectors shall be in conditioned space or be PASS FAIL N/A listed for non-conditioned spaces(outside,parking decks,areas with ❑ ❑ ❑ low or high temperatures). 9. DUST COVERS-Verify all dust covers have been removed. PASS FAIL N/A ❑ ❑ ❑ DUCT SMOKE DETECTORS 10. SAMPLE TEST-The fire inspector will select a sample of Duct Smoke PASS FAIL N/A Detectors at random to be tested by using smoke or a listed aerosol. ❑ ❑ ❑ Minimum of one per floor and no less than 10%of the devises shall be tested. (Duct Smoke Detectors shall be programmed to be a supervisory condition at the FACP.) 11. HVAC SHUTDOWN-Verify that HVAC shutdown is operational.After PASS FAIL N/A the initial test and verification,it is acceptable to activate the HVAC ❑ ❑ ❑ bypass to avoid excessive restarting. 12. CLOSE UPON ACTIVATION-All remaining duct smoke detectors not PASS FAIL N/A tested shall be inspected to verify that they close upon activation of the ❑ ❑ ❑ fire alarm system. 13. ACCESS DOOR-At each duct detector a 12"x12"minimum access door, PASS FAIL N/A hinged or latched type,is provided to facilitate sampling tube inspection ❑ ❑ ❑ and cleaning.Doors shall have a label that reads: FIRE/SMOKE DAMPER,SMOKE DAMPER OR FIRE DAMPER. 14. AIR FLOW DECAL-Air flow direction is permanently indicated on the PASS FAIL N/A duct by stencil or decal,to help assure the sampling tubes are installed ❑ ❑ ❑ and maintained in the correct orientation. 15. INTAKE TUBE-Intake tube has its holes/slots facing into the air PASS FAIL N/A stream,and a stopper installed to seal its far end. ❑ ❑ ❑ HEAT DETECTORS 16. SAMPLE TEST-The fire inspector will select a sample of Heat Detectors PASS FAIL N/A at random to be tested. ❑ ❑ ❑ (Minimum of one per floor and no less than 10%of the devises shall be tested). 17. MANUFACTURES SPECIFICATION-Important to follow the PASS FAIL N/A manufactures specification on the correct testing of the device. ❑ ❑ ❑ (Incorrect testing can damage devices) MANUAL FIRE ALARM BOX(PULL STATIONS) 18. 100%ACTIVATION- 100%of Manual Fire Alarm Box(Pull Stations) PASS FAIL N/A provided shall be tested by physical activation. ❑ ❑ ❑ Page 6 of 8 v1.2023 19. LOCATION-Manual fire alarm boxes shall be located as follows: PASS FAIL N/A • At a conspicuous,unobstructed,and assessable location. ❑ ❑ ❑ • Within 60 inches of exit doorway openings. • Mounted between 42 to 48 inches above the floor 20. ADDRESSABLE-Verify that upon activation of a manual fire alarm box PASS FAIL N/A the alarm signal to the main fire alarm panel is correctly addressed with ❑ ❑ ❑ an accurate description. 21. COLOR-Manual fire alarm boxes shall be red in colors on a background PASS FAIL N/A of contrasting color. ❑ ❑ OTHER INITIATION DEVICES 22. OTHER DEVICES-Combination Detector,Electrical Conductivity Heat PASS FAIL N/A Detector,Fire-Gas Detector,Flame Detector,Pneumatic Rate-of-Rise ❑ ❑ ❑ Tubing Heat Detector,Projected Beam-Type Detector,Radiant Energy- Sensing Fire Detector,Rate Compensation Detector,Spark/Ember Detector,Spot-Type Detector shall follow the manufactures specification on the correct testing of that device. STEP 8: ELECTRICALLY LOCKING AND/OR SELF-CLOSING DOORS Date Initial DOOR RELEASES 1. MAGNETIC DOOR HOLD-Verify that all Magnetic Door Hold-Open PASS FAIL N/A Release Devices work when the system is in alarm.The doors shall close ❑ ❑ ❑ completely and latch. ELECTRICALLY LOCKED DOORS 2. ELECTRICALLY LOCKED DOORS-Electrically locked doors that are PASS FAIL N/A part of the required means or egress shall comply with the following: ❑ ❑ ❑ • Unlock immediately upon loss of power. • Unlock upon activation of the fire alarm system and remain unlocked until the fire alarm condition is manually reset. • Unlock upon activation of the automatic sprinkler system. DELAYED EGRESS LOCKING SYSTEM 3. ACTIVATION-Verify that the delay electronics of the delayed egress PASS FAIL N/A locking system deactivates upon actuation of the automatic sprinkler system or automatic fire detection system,allowing immediate,free egress. SMOKE AND FIRE PROTECTIVE CURTAIN ASSEMBLIES 4. QUALIFIED PERSONAL-Testing of protective curtain assemblies shall PASS FAIL N/A be performed by a qualified person with knowledge and understanding ❑ ❑ ❑ of the operating components of the type of assembly being subject to testing. S. TESTING TWICE PER DEVICE-All smoke/fire protective curtains that PASS FAIL N/A are connected to the fire alarm system shall be tested a minimum of ❑ ❑ ❑ twice per device. 6. CLOSING WITHOUT POWER-All protective curtain assemblies shall be PASS FAIL N/A capable of closing the curtain without power. ❑ ❑ ❑ 7. DELAYS-Protective curtain assemblies shall not have a delay in the PASS FAIL N/A initiation of closing of more than 10 seconds. ❑ ❑ ❑ 8. CLOSING SPEED-Protective curtain assemblies shall have an average PASS FAIL N/A closing speed of not less than 6 in./sec or more than 24 in./sec. HORIZONTAL SLIDING ACCORDIAN OR FOLDING FIRE DOORS Page 7 of 8 v1.2023 9. HORIZONTAL SLIDING,ACCORDION OR FOLDING DOORS-All PASS FAIL N/A special-purpose horizontal sliding,accordion or folding doors that are a ❑ ❑ ❑ component of a means or egress shall comply with the following: Connected to the fire alarm system and close when in alarm. Shall be power operated and shall be capable of being operated manually in the event of power failure. The door assembly shall have an integrated standby power supply. Exiting hardware shall accommodate for a person with disabilities,have sharp contrast from the door's surface,and include both graphic images and bold lettering. (Example:PUSH TO OPEN) The door shall open to the minimum required with within 10 seconds after activation of the operating device. STEP 9: AREA OF REFUGE EMERGENCY COMMUNICATION Date Initial 1. 100%TESTED-All devices associated with the Area of Refuge PASS FAIL N/A Emergency Communication shall be tested. ❑ ❑ ❑ 2. OPERATION-The area of refuge station shall provide for hands-free, PASS FAIL N/A two-way communication,provide an audible and visible signal to ❑ ❑ ❑ indicate communication has occurred,and indicate to the receiver the location sending the signal. 3. INSTRUCTIONS-Instructions for the use of the two-way PASS FAIL N/A communications system,instructions for summoning assistance via the ❑ ❑ two-way communications system,and written identification,including in braille,of the location shall be posted adjacent to the two-way communications system. 4. RESPONSE-If the central control point is not constantly attended,it PASS FAIL N/A shall have a timed automatic communications capability to connect with ❑ ❑ ❑ a constantly attended monitoring location where responsible personnel can initiate the appropriate response. S. QUALITY AND CLARITY-Verify voice quality and clarity. PASS FAIL N/A ❑ ❑ ❑ STEP 10T EMERGENCY RADIO COMMUNICATIONS Date Initial 1. EMERGENCY RADIO COMMUNICATIONS-Simulate the following PASS FAIL N/A trouble conditions: ❑ ❑ ❑ • Signal Booster Trouble • Antenna Failure • Loss of Normal AC Power • Failure of Battery Charger • Low Battery Capacity STEP 11: SYSTEM IN FULL OPERATION Date Initial 1. NORMAL CONDITION-Ensure all systems are normal. PASS FAIL N/A ❑ ❑ ❑ 2. OFF OF TEST-Ensure the Fire Alarm is off of test with the monitoring PASS FAIL N/A company. ❑ ❑ ❑ 3. RECORD OF COMPLETION-Have the company complete and submit PASS FAIL N/A the Record of Completion. ❑ ❑ ❑ 4. DOCUMENT BOX-Have all manuals and the program placed in the PASS FAIL N/A document box. ❑ ❑ ❑ 5. KNOX BOX-Keys for the FACP and pull station(s) shall be provided so PASS FAIL N/A they may be placed into the Knox Box. ❑ ❑ Page 8 of 8 v1.2023