Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19703 Knoll Dr_BLD6140_2025
Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Permit Number: BLD6140 Permit Type: Residential Mechanical Address/Parcel: 19703 Knoll Dr Completed (Month/Year): October 2024 Land Use Bonding or Assignment of Funds Notice of Decision o Confidential Documents. Contact the Staff Report City to obtain. Application As-Builts Narrative Letters and Project Documents Legal Description Other: Vicinity Map Site Plan Civil Landscape Plan Issued Permit Complete Streets Checklist Application Traffic Impact Analysis Other Applications Snohomish County Traffic Mitigation Offer Construction Calculation Worksheet WSDOT Traffic Offer Form Approved Plans Tree Survey Review Comment Form Stormwater Drainage Report Letters and Project Documents Geotech Report Other Agency Permits Critical Area Evaluation Form Reports: SEPA Checklist o Drainage Report Pg: Public Notice Material o Stormwater Pg: Noticing and Related Documents o Geotech Pg: Water / Sewer Availability Certificate o All Other Reports Unanticipated Discovery Plan Form SEPA and Noticing Materials Aerial Photo of Site Inspections Proposed Building Materials As-Builts Lighting Plans and Lighting Cut Sheets Other: Color Elevations Design Matrix Building Plat Map ✔ Issued Permit Title Report ✔ Application Lot Closures Additional Applications Preliminary Civil Plans Approved Plans Archaeological Survey Site Plan o Confidential Documents. Contact the Letters and Project Documents City to obtain. Calculations Topography (Existing Conditions) ✔ Project Specification Manuals CC&R’s Reports Deeds / Easements / Conveyances Certificate of Occupancy /Dedications Inspections Developer’s Agreement Other: Letters and Project Documents Page 1 of 1 AUD2B060A9V-SPEC-1 TAG: _________________________________ Specification Upflow / Horizontal Gas Furnace - Variable Speed - 2 Stage Heat AUD2B060A9V3VB 5/8" 17-1/2" 16-1/4" 5/8" 28-3/8" 19-5/8" 1/2" 5/8" 4" DIAMETER FLUE CONNECT 7/8" DIA. HOLES ELECTRICAL 9-5/8" CONNECTION 4-1/16" 1/2" 3/4" 2-1/16" 7/8" DIA. K.O. 3-15/16" ELECTRICAL CONNECTION 16" 8-1/4" (ALTERNATE) 40" 3-3/4" 1-1/2" DIA. 3/4" K.O. GAS CONNECTION 2-1/16" (ALTERNATE) 28-1/4" 28-1/4" 3/4" 22-1/2" 23-1/2" 5-5/16" 3-13/16" 1-1/2" DIA. HOLE 3/8" GAS CONNECTION 2-1/8" © 2010 American Standard Heating & Air Conditioning *UD2B060A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 589 604 619 604 607 LOW ON ON TEMP. RISE 49 48 47 48 48 WATTS 65 95 125 160 200 HEATING CFM 663 694 684 681 686 1ST MEDIUM ** ON OFF TEMP. RISE 44 42 42 42 42 STAGE WATTS 75 120 145 185 220 CFM 775 781 776 805 811 HIGH OFF OFF TEMP. RISE 37 37 37 36 36 WATTS 105 145 180 230 270 CFM 813 818 818 837 842 LOW ON ON TEMP. RISE 55 54 54 53 53 WATTS 110 150 185 240 280 HEATING CFM 907 919 942 958 959 2ND MEDIUM ** ON OFF TEMP. RISE 49 48 47 46 46 STAGE WATTS 140 200 240 300 330 CFM 1038 1066 1086 1089 1079 HIGH OFF OFF TEMP. RISE 43 42 41 41 41 WATTS 190 260 325 365 415 *UD2B060A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW UNIT SIZE (TONS) SETTING SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW CFM 499 537 520 520 500 (350 CFM/ ON ON OFF ON TON) WATTS 50 80 110 145 175 NORMAL CFM 605 610 610 597 593 1.5 (400 CFM/ ON ON OFF OFF TON) WATTS 60 80 120 155 180 HIGH CFM 649 681 665 665 672 (450 CFM/ ON ON ON OFF TON) WATTS 75 110 145 180 220 LOW CFM 680 722 680 696 696 (350 CFM/ OFF ON OFF ON TON) WATTS 80 125 150 190 225 NORMAL CFM 798 804 809 823 818 2 (400 CFM/ OFF ON OFF OFF TON) WATTS 105 145 170 235 280 HIGH CFM 884 896 924 931 931 (450 CFM/ OFF ON ON OFF TON) WATTS 145 180 240 280 330 LOW CFM 858 863 882 894 895 (350 CFM/ ON OFF OFF ON TON) WATTS 125 175 220 275 320 NORMAL CFM 984 1017 1038 1017 1017 2.5 (400 CFM/ ON OFF OFF OFF TON) WATTS 170 225 295 330 375 HIGH CFM 1125 1138 1150 1161 1161 (450 CFM/ ON OFF ON OFF TON) WATTS 245 315 370 435 475 LOW CFM 1035 1056 1076 1076 1076 (350 CFM/ OFF OFF OFF ON TON) WATTS 205 265 330 370 430 NORMAL CFM 1208 1247 1268 1278 1200 ** 3 ** OFF OFF OFF OFF (400 CFM/ WATTS 300 360 440 485 490 TON) HIGH CFM 1380 1410 1402 1350 1235 (450 CFM/ OFF OFF ON OFF TON) WATTS 440 500 550 550 525 NOTES: 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES. 5. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. INDOOR BLOWER TIMING COOLING OFF - DELAY OPTIONS Heating: The ECM Fan Control controls the variable speed NOMINAL SWITCH SETTINGS SELECTION indoor blower. The blower "on" time is fixed at 45 seconds after AIRFLOW ignition. The FAN-OFF period is field selectable by dip switches 5 - OFF 6 - OFF NONE SAME #2 and #3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit wiring 5 - ON 6 - OFF 1.5 MINUTES 100% * diagram). 5 - OFF 6 - ON 3 MINUTES 50% Cooling: The fan delay-off period is set by dip switches on the 5 - ON 6 - ON ** 50 - 100% ECM Fan Control board connected to the Integrated Furnace Control. The options for cooling delay off is field selectable by * - This setting is equivalent to BAY24X045 relay benefit dip switches #5 and #6. However, dip switch #1 on the ** - This selection provides ENHANCED MODE, which is a Integrated Furnace Control must be set to "ON" for cooling ramping up and ramping down of the blower speed to provide mode to function properly. improved comfort, quietness, and potential energy savings. The following table and graph explain the delay-off settings: See Wiring Diagram notes on the unit or in the Service Facts for complete wiring setup for ENHANCED MODE. The graph which follows, shows the ramping process. ** - This selection provides a ramping up and ramping down of the blower speed to provide improved comfort, quietness, and potential energy savings. The graph below shows the ramping 100% if necessary process. 80% Dehumidify 50% 50% Fast Coil Cooling Efficiency OFF OFF 1 7.5 3 minute minutes minutes General Data 1 TYPE Upflow / Horizontal VENT COLLAR — Size (in.) 4 Round RATINGS 2 HEAT EXCHANGER 1st Stage Input BTUH 39,000 Type-Fired Alum. Steel 1st Stage Capacity BTUH (ICS) 3 31,200 -Unfired 2nd Stage Input BTUH 60,000 Gauge (Fired) 20 2nd Stage Capacity BTUH (ICS) 3 48,000 ORIFICES — Main Temp. rise (Min.-Max.) °F. 30 - 60 Nat.Gas. Qty. — Drill Size 3 — 45 BLOWER DRIVE DIRECT L.P. Gas Qty. — Drill Size 3 — 56 Diameter-Width (In.) 10 x 7 GAS VALVE Redundant - Two Stage No. Used 1 PILOT SAFETY DEVICE Speeds (No.) VARIABLE SPEED Type Hot Surface Ignition CFM vs. in. w.g. See Fan Performance BURNERS — Type Multiport Inshot Motor HP 1/2 Number 3 R.P.M. VARIABLE POWER CONN. — V/Ph/Hz 4 115/1/60 Volts/Ph/Hz 115/1/60 Ampacity (In Amps) 10.5 COMBUSTION FAN - Type Centrifugal Max. Overcurrent Protection (amps) 15 Drive - No. Speeds Direct - 2 PIPE CONN. SIZE (IN.) 1/2 Motor HP - RPM 1/100 - 2543 / 1727 DIMENSIONS H x W x D Volts/Ph/Hz 115/1/60 Crated (In.) 41- 3/4 x 19-1/2 x 30-1/2 F.L. Amps 0.70 / 0.40 Uncrated (In.) 40 x 17-1/2 x 28-1/2 FILTER — Furnished? Yes WEIGHT Type Recommended High Velocity Shipping (Lbs.) / Net (Lbs) 136 / 126 Hi Vel. (No.-Size-Thk.) Shipped 1 - 17 x 25 - 1in. 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 3 Based on U.S. Government Standard Tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS — Central heat- BURNERS — Multi-port, in-shot burners will STYLING — Heavy gauge steel and "wrap- ing furnace designs are certified to ANSI give years of quiet and efficient service. All around" cabinet construction is used in Z21.47 / CSA 2.3 for both natural and L.P. models can be converted to L.P. gas without the cabinet with baked-on enamel finish for gas. Limit setting and rating data were changing burners. strength and beauty. The heat exchanger established and approved under standard section of the cabinet is completely lined INTEGRATED SYSTEM CONTROL— Ex- rating conditions using American National with foil-faced fiberglass insulation. This clusively designed operational program pro- Standards Institute standards. results in quiet and efficient operation due to vides total control of furnace limit sensors, the excellent acoustical and insulating quali- SAFE OPERATION — The Integrated Sys- blowers, gas valve, flame control and in- ties of fiberglass. tem Control has solid state devices, which cludes self diagnostics for ease of service. continuously monitor for presence of flame, FEATURES AND GENERAL OPERATION AIR DELIVERY — The variable speed, di- when the system is in the heating mode of — These High Efficiency Gas Furnaces rect-drive blower motor, with sufficient air- operation. Dual solenoid combination gas employ a Hot Surface Ignition system, which flow range for most heating and cooling valve and regulator provide extra safety. eliminates the waste of a constantly burning requirements, will switch from heating to pilot. The integrated system control lights QUICK HEATING— Durable, cycle tested, cooling speeds on demand from room ther- the main burners upon a demand for heat heavy gauge aluminized steel heat ex- mostat. The blower door safety switch will from the room thermostat. Complete front changer quickly transfers heat to provide prevent or terminate furnace operation when service access. warm conditioned air to the structure. Low the blower door is removed. (Fan relay and energy power vent blower, to increase 35VA control transformer is standard). a. Low energy power venter. efficiency and provide discharge of gas b. Vent proving differential switch. fumes to the outside, allows common vent- ing with hot water heater. Since American Standard Heating & Air Conditioning has a Library - policy of continuous product and product data improvement, Product Section - it reserves the right to change specifications and design without notice. Product Furnace Model AUD2-9V Technical Literature - Printed in U.S.A. Literature Type Specification Sequence - American Standard Date 08/10 Heating & Air Conditioning 6200 Troup Highway File No. AUD2B060A9V-SPEC-1 Tyler, TX 75707 Supersedes AUD060R9V-SPEC-1 !"! #$%& '()*+( ,-%.& /+012+/3"*'24(5'(04+ ,-%.,6677 892'2*:*;42*< ,-%.=>=?=@ '+A1:4BB*CD9 >#.% E*114F'FG;*+3'( H#. I JI J9 9 K- /LL4F*M(/+012+/3G*'24(5NF/3 ?%##OP#Q *RB'F*<'1S;+('F* T-U#. 8 N ?VUW I &UX#O?#7 >#.7U%#. YZ [%%U.%\#U JI]*140*(24'B ^>#6 ^77U6 K_7 8 W# !"! ?U7 !` a ,77b.6# )+4124(S/12*+ # a'+F*Bc 00+*11*5'B*1F+4R24/(`d(*+'3* `d(*+aG/(* e/(4(5 < )Ef 9 9 I)` S g ` ! >#.%#7 !/(2+'F2/+a+43'+A!/(2'F2aG/(*00+*11!/(2+'F2/+AR*4F*(1* 4F*(1*c `` 892'2*:*N !`h!` 8JII8J 9 !` "<f! 2*N< !`!` `` 892'2*:*N !`h!` 'i/+f 8JII8J 9 `" "<f! 2*N< !`!` (0;12+4*1 ^.7%#.7 '2*(1R*F24/(AR**1F+4R24/(FG*0;B*0'2*!/3RB*2*0'2*(1R*F2/+2'2;1 !"!# "$%#" & !#' (#)'* + # "!# +, -!-./"-0- - (1#"-2-3-%#!" + 4 (/#! /)-/&$!"- + !"-/- ! + 56789 :;<<=>? @778ABC-D77E /" "" !"!# F, GHIJKILM-NOPQIR F, SOT-UVPQW-XOYIKOLRIZJ-[O\]ZLI\ZJ-^__JI\ZRIVL `8abc7 /" &/!-* !"!#&/*$#"-* "-*$%#" d&-#3e F, + F,Ff F, g/#-./#)*hi#F,Ff + jk778cClcm-n898cA :?=?? op968CC-l9 /" !)- /$ F, qqrstuqvWqwqxwyqz{G|}srxw{~YYHOKNOPQIR_K€ F, qqrszsrxWqwqxwyqz{G|}srxw{Â_O\Y_K€ F, qqrszsrvWqwqxwyqz{G|}srxw{^__JI\ZRIVL_K€