i 820TA/821 TA PreferredTm Two-Stage, Variable Speed, Non-Communicating, Non-Condensing, Gas Furnace Input Capacities: 45,000 thru 135,000 BTUh 13mia Product Data PERFORMANCE ® ® • Perfect Heat®operation ®®®® Two-stage heating even with single-stage thermostat-patented EAdaptive Control Technology t ®®®® Reduced operating sound through low-stage operation and e E�f5 t!�e�_=5 sound elimination combustion system Two-stage heating with single-stage thermostat with patented Adaptive Control Technology ' Lower operating sound through low-stage operation and QuieTechTht system 1 Microprocessor based"smart"control center Fan on-Continuous Fan speed adjustable from thermostat Adjustable heating air temperature rise Adapts heating stages to meet demand Dehumidify mode Enhanced diagnostics with LED and reflective sight glass, non-volatile fault code memory,and self test feature On-board fuse for transformer protection • Stores fault codes during power outages •AI80220 Perfect Lig0f Igniter • Draft Safeguard switch designed to ensure proper furnace venting THE TWO-STAGE GAS FURNACE Insulated blower compartment The Two-stage,Variable-speed,Non-communicating Gas Furnace offers Inner door for tighter sealing outstanding comfort in an 80%AFUE furnace.You get the benefits of Variable-speed,constant torque ECM blower motor Perfect HeatThr:reduced drafts,reduced sound levels,longer cycles,less Increased SEER ratings for AC and HP systems as compared to the temperature swings between cycles, less temperature differences Air Conditioning Heating and Refrigeration Institute's standard between rooms, and improved indoor air quality. Plus, it features a coil-only rating when paired with selected Bryant evaporator coils. dehumidify mode and the ability to change continuous fan speeds from Noise reduction combustion system the thermostat. The 820TA/821TA furnaces are approved for use with INSTALLATION FLEXIBILITY natural or propane gas. 821TA - Low NOx units are designed for California installations and can be installed in air quality management 4-way Multipoise furnace,13 vent applications districts with a 40 ng/J NOx emissions limit. Compact design-only 33-1/3 in.(847 mm)tall APPLICATIONS • SmartEvapTNr Humidity control when using a ThermidistatT°I control • SmartEvapTM can lower the humidity level in the home by nearly 10 `St0\\r17111/��'f percent • All models are Chimney friendly when used with accessory vent kit PreferredFA Twinning capable with accessory kit (sizes 48070, 48090, 60090, 66110,and 66135) ISO 9001 a Quality HYBRID HEAT®Dual Fuel System compatible "Imp °E IG" CERTIFICATION owed CERTIFIED.. s • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air Use of the ARM Certified TM Mark indicates a `FRTIF� �� leakage less than 1.4%at 0.5 in.W.C.when tested in accordance with manufacturer's partieipation in the program.For ASHRAE standard 193 verification ofecrtification for individual products, go to www.ahridimctory.org. • Residential installations eligible for consumer financing through the Retail Credit Program A200316 820TA/821TA:Product Data DIMENSIONAL DRAWING Zi� II—1{i l.fl ID 9 SECTI01 2-I S Ile XALC l:lf I11D.n 2 Illi I Sl.il 0 11111{ IeJ.51 C C rot VIE. Oil 22 ISllf 122.21 IS82.41 ACCEss0tl(2) 22 111 151,SI 22 Ulu 11 ISllf 21 Slf IS7I.11 1 ISlli [ff.21 (fxf.Jl [ISO.n 3 111f A If I1G [ei.el R 150i.{1 II/C?It AIR 1101 '—"I 11Ie65I a Un.11 Wil[T e rnf z¢z1s t�titl 0- JUNCT[o.mi P's:Exis o— tSiTilAr i-r rW--E-E--x—r11-- f urn Lollrtol zfo —_—_—_—_—_—_ ALlE1RATC • Y ( bI1 li ENi 51 21 . CLIO DUN 127 70111 GAS INTRI 175011 LOCAT/ naI2 fiern.n ve I ACCESSORY — (911i -- ACCE22T1 5 %ACCE5m2e2 11 01r I�z eOnINn S.IID1E s1 L----------- / r-------------I 1 21 510 G Ile 110C.OUTS CORD 22 inf 1 l549.51 ROrTd INLET 1155.i1 D DID YENTIA9 IS(LACES) 1560SI0�TilfT�J1 I2S.11 1 114 2e JId DO ITCH RETURN I1S.11 2f Illf 131.81 1121.11 if 1I0rN [ff2.01 2{111f I131.ft I611,51 A190084 A B C D ACCESSORY TOP AND VENT FILTER SHIP WT. FURNACE SIZE CABINET OUTLET (BOTTOM CONNECTION LB KG) MEDIA WIDTH WIDTH BOTTOM FLUE INLET WIDTH SIZE CABINET COLLAR SIZE 36045V14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 111 (50) 16(406) 3607OV14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 118(54) 16(406) 4807OV17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 132(60) 16(406) 4809OV17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 131 (59) 16(406) 60090V21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 142(64) 20(506) 19-3/8 492 13-5/16 338 19-1/2 495 4(102) 154(70) 20(506) 66110V21 21 (533) ( ) ( ) ( ) 66135V24 24-1/2(622) 22-7/8(581 15-1/16(383) 23(584) 4(102)• 168(76) 24(610) I *. 135 size furnaces require a 5 or 6-in.(127 or 152 mm)vent.Use a vent adapter between furnace and vent stack.See Installation Instructions for complete installation requirements. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 2 820TA/821TA:Product Data EXAMPLE OF MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6,7 8-10 11 12-13 14 15 16 Heat Major Cooling Voltage Minor Exchanger Tier/NOx AFUE/NOx Heating Stages Series Capacity(CFM) Heal Input Motor Type Width (1-phase) Un-used Seri s 9 6 7 M B 42 060 C 17 A - A C=Comm.Variable- 8 Speed A 0-80% Constant Airflow B 14-14.2' O=Base 1=80%low Noz (VCA)ECM 17-175' F.=-..v,..,z C /=Legacy Line "— E=Fixed-Speeds 1 -21 0' 2=Preferred 2=92% Constant Torque 5=95% (FCT)ECM 24=24.5' 3=Ultra Low Nox 24=800 CFM 6=96% V=Variable-Speed 8=Evolution 30=1000 CFM 026=26,000 BTU/h 7=97% A 36=1200 CFM Constant Torque 8=98% M=Modulating 040=40,000 BTU/h (VCT)ECM S=Single Stage B 42=14DO CFM 060=60,000 BTU/h T=Two-Stage C 48-1600 CFM _ D 60=20DO CFM -- 66=2200 CFM A 190404 FURNACE COMPONENTS INDUCER MOTOR VENT ASSEMBLY ELBO\Y MAIN LIMIT SWITCH PRESSURE (BEHIND GAS VALVE) SWITCH Bill BLOCKED VENT SWITCH FLUECOLLECTOR Box i O FLAME SENSOR GAS VALVE 1 6 eI o MANUALRESET GAS MANIFOLD LIMIT SWITCHES HOT SURFACE IGNITOR GAS BURNER 0 BLOWER DOOR SAFETY SVrtTCH FURNACE CONTROL BLOWER AND BOARD m MOTOR I A 190086 NOTE:The furnaces are factory shipped for use with natural gas.These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. A WARNING INSTALLATION MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION Tlu lareea ar limaca N m b eryewe u . epgge0 b use e.N rental Umow..Dob—ON, ant snlseMraSNstment a0er+ smica, pas at aaei0ea 0-10,0000 HORIZONTAL Fsfaaaeons. malnlmarw.abata44m (0-O.0SO +- da rtl eE� serous kq"wMafls M amessary Wl—r-by ' lnuu vbVmr React ant IsOon bsbucawia arN ��Nas u� _ IaeoNuns M Uuls 'AQ pmiMO MO�Wslurruw.Imtaaauw al pas ePpfu'rtrc\s. ant servke must M grlemr0 M a TNs Nnra 6 b YtloOr f��as RualiaM se.ex..peray wu.araa i�nGaarm YiabuOarq auPPGr. �uwep on.act. TNs funura may Ee iuuaea _ A CAUTION m m^wswle fianM In a�.e ' el,ear mw.aaz aaa..nby b IeaLs,IM a absel al�a.n aexawe p J ryn0�q u,Is—bang.- m.a,sre'a.�maYn'aL flu lurum may De usee waA Oeravw Ydes INSTALLATION a Tyas B-1 v>ex a.,a may De Vaa LTesrru emrrimmYa i I.Tbis M1rnate r�uA beiWaOaJti \eNedFepmmsrM Wcr (o Sl je\Yaswbfiiafv(BFpl amow�re aanlre maa+araran agar em+a�ea. wT>w Bt\alrmati.nl+wl "'b1LOd1 an°�\bOP1 b�° MINIMUM INCHES CLEARANCE TO Fauei Gras taa u+smrIrNFPAsr COMBUSTIBLE CONSTRUCTION a C54&119.i Gaz Y\sfasaTm COJe. 2.Tie hanace mut Ee iuroseE baien as OOWNFLOY/POSITIONS: Pouau fa mMaOon ant satlalan T Inslaaa6on m mrmrDuslDb Moors oN/. .See mat4atluNs nslaAaeon YJonnaOm perEed wM fb apptare. Frc YssNasOon en m�WrsCLe lmiq aJy xte iublleE on sµ'al A y,Pal Ib.KGABBOa11ALL rc NAHA01101 s8,Coi Aud101, OPERATION Pan No.uue.va,eesv,CNR/,ENWXENJyaX weNc.wnae. n.wee ec�oPFeO»w maMw resa oawlrnv. -s+iKMea)1\dcror mrpxbnent b 0 10 irlies hvY tleamrra reauYeE br ekwe. pep apa'vsst o'+�beal mrK4nu tat rcu11 barn iraaeCaaze mmbuseon •b6oles soppy a reban L P x^en Osrum is ti tlr IVIr by swpy or pwea\enl mnanons_ pes�T ha mNap oay Pe.ms..ab een.cen Ines bm�aa by 1.m not brpaa+rvra e.rp.l,ee. ale.eacuon,p m.reP,m mo san p nb runau(xxeL f.Hafnisppw.®saRwafe4 J_.�,a� mmn�mmmi .eman,an b mrrea u,e p�pn aro revel an.1 s..wm. A10269 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 3 820TA/821TA:Product Data SPECIFICATIONS Unit Size 36045V14 3607OV14 4807OV17 4809OV17 6009OV21 6611OV21 66135V24 RATINGS AND PERFORMANCE All Standard High 44,000 66,000 66,000 88,000 88,000 110,000 132,000 All Low NOx Low 29,000 43,500 43,500 58,000 58,000 72,500 87,000 Input Btuh Upflow Nonweatherized ICS All Low Nox High 42,000 63,000 63,000 84,000 84,000 105,000 126,000 Downflow/ Low 29,000 43,500 43,500 58,000 58,000 72,500 87,000 Horizontal All Standard High 35,000 53,000 53,000 71,000 71,000 89,000 107,000 All Low NOx Low 23,000 35,000 35,000 47,000 47,000 59,000 70,000 Output Capacity(Btuh) Upflow Nonweatherized ICSt All Low Nox High 34,000 51,000 51,000 68,000 68,000 85,000 102,000 Downflow/ Low 23,000 35,000 35,000 47,000 47,000 59,000 70,000 Horizontal AFUE$ 80.00 High 30-60 30-60 25-55 40-70 25-55 30-60 40-70 Certified Temperature Rise Range°F(°C) (17-33) (17-33) (14-30) (22-39) (14-30) (17-33) (22-39) Low 20-50 30-60 15-45 30-60 15-45 20-50 25-55 (11-28) (17-33) (8-25) (17-33) (8-25) (11-28) (14-31) Certified External Static Heat/Cool 0.10/0.50 0.12/0.50 0.12/0.50 0.16/0.50 0.15/0.50 0.20/0.50 0.20/0.50 Pressure Heating High/Low 915/780 1180/715 1400/1225 1380/1005 1800/1570 2055/1685 1 2075/1795 Airflow CFM Cooling 1175 1380 1740 1505 1915 2230 2160 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min/Max 104/127 Maximum Unit Amps 7.70 8.00 10.50 8.60 11.50 13.10 13.90 Maximum Wire Length(Measure one way in Ft.(M)) 35(10.9) 34(10.4) 26(8.1) 32(10) 24(7.5) 34(10.4) 32(9.8) Minimum Wire Size 14 14 14 14 1 14 12 12 Maximum Fuse or Ckt Bkr Size(Amps)ft 15 15 15 15 1 15 20 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Burners(Monoport) 2 3 3 1 4 1 4 5 6 Gas Connection Size 1/2in.NPT GAS CONTROLS Mfr. WhiteRodgers Gas Valve Min.inlet pressure 4.5(Natural Gas) (Redundant) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Variable-Speed Constant Torque(VCT)ECM 1/2 1/2 3/4 112 3/4 1 1 Motor Full Load Amps 6.4 6.7 9.2 6.7 9.6 10.9 11.7 RPM(Nominal) 1200 1200 1200 1200 1200 1200 1200 Blower Wheel Diameter x Width -In.(mm) 10 x 6 10 x 6 11 x 8 10 x 10 11 x 11 11 x 11 11 x 11 (254x152) (254x152) (279x203) (254x254) (279x279) (279x279) (279x279) *. Gas input ratings are certified for elevations to 2000 ft.(610 M). For elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft.(305 M)above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2012 Table FA or furnace installation instructions. t. ICS=Isolated Combustion System $. Capacity in accordance with U.S.Government DOE test procedures **. Airflow shown is for bottom only return-air supply for Max Cooling Airflow and heating airflows(efficiency setting)at certified external static pressure.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each remm-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in.(I10 min)wide,high efficiency media filter. tt. Time-delay type is recommended. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 4 820TA/821TA:Product Data ACCESSORIES DESCRIPTION PART NO. 36045V14 3607OV14 4807OV17 4809OV17 6009OV21 6611OV21 66135V24 FHG1425-2 X X - - External Bottom Return Filter FHG1625-2 - X X - - Rack FHG2025-2 - - - X X - FHG2424-2 - - - X 325531-402 X X X X - - - Unframed Filter 3/4-in.(19 mm) 325531-403 - - X X 325531-404 - - - - - X Flue Extension KGAFE0112UPH X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X Downflow Vent Guard KGBVG0101 DFG X X X X X X X Vent Extension Kit KGAVE0101 DNH X X X X X X X Chimney Adapter Kit KGACA02014FC X X X X X X X KGACA02015FC X X Natural-to-Propane Conversion AGAGC8NPS01A X X X X X X X Kit• Propane-to-Natural Conversion AGAGC8PNS01A X X X X X X X Kit Twinning Kit VCT-ECM Motor AGATWNPME01B - X X X X X High Altitude Pressure Switch Kit KGAHA5801PSW I X X X X X X X *. Factory-authorized and field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized. X=Accessory DESCRIPTION Gas Orifice Kit-#42(Nat Gas) LH32DB207 Gas Orifice Kit-#43(Nat Gas) LH32DB202 Gas Orifice Kit-#44(Nat Gas) LH32DB200 Gas Orifice Kit-#45(Nat Gas) LH32DB205 Gas Orifice Kit-#46(Nat Gas) LH32DB208 Gas Orifice Kit-#47(Nat Gas) LH32DBO78 See Installation Instructions for model,altitude, Gas Orifice Kit-#48(Nat Gas) LH32DBO76 and heat value usages. Gas Orifice Kit-#54(LP) LH32DB203 Gas Orifice Kit-#55(LP) LH32DB201 Gas Orifice Kit-#56(LP) LH32DB206 Gas Orifice Kit-1.25mm(LP) LH32DB209 Gas Orifice Kit-1.30mm(LP) LH32DB210 DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL • Bryant has a wide variety of thermostats for your system,please visit www.Biyant.com to see all thermostat and IAQ products. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 5 820TA/821TA:Product Data ACCESSORIES (continued) DESCRIPTION ACCESSORY 14" 17" 21" 24" Bryant Carbon Monoxide Alarm(10 pack)t COALMBBNRR02-A10 X I X X X Bryant Evolution Air Purifier-16x25(407x635 mm) DGAPAXX1625 X X Bryant Evolution Air Purifier-20x25(508x635 mm) DGAPAXX2025 X X Bryant Evolution Air Purifier Repl.Filter-16x25(407x635 mm) GAPBBCAR1625-A05 X X - Bryant Evolution Air Purifier Repl.Filter-20x25(508x635 mm) GAPBBCAR2025-A05 X X Cartridge Media Filter- 16"(407 mm)(MERV 11) FILXXCAR0116 X X Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 X Cartridge Media Filter-20"(508 mm)(MERV11) FILXXCAR0120 X Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 X Cartridge Media Filter-24"(610 mm)(MERV11) FILXXCAR0124 X EZ Flex Cabinet Side or Bottom-16" EZXCABCR0016 X X - EZ Flex Cabinet Side or Bottom-20" EZXCABCR0020 X X EZ Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 X EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 - X EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNVO016 X X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 13) EXPXXUNV0316 X X - EZ-Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNVO020 X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNV0320 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNVO024 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNV0324 X Media Filter Cabinet-20" FILCABXL0020 - X - Media Filter Cabinet-24" FILCABXL0024 X Media Filter Cabinet-16" FILCABXL0016 X X TYPICAL WIRING SCHEMATIC ----FIELD 24-VOLT WIRING ----FIELD 115-,208/230-,460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-VOLT WIRING NOTE 2 1-STAGE FIVE w e Y R G THERMOSTAT FIELD-SUPPLIED WIRE I I I I I TERMINALS FUSED DISCONNECT I I I I I THREE-WIRE I I I I —' '-- HEATING- _ N —_—_ -- -- 208230 L O R 460 ONLY VOT --- THREE K PHASE V L--BK • I I -I-----4-----+— ----- __T I I I I --- 208/230- -- --- ----- -- ----- i_J_ I N __ Ere___VOLT INGLE 115VOLTFIELD- JUNCTION rcz NOTE1____=_1 1 : ---�-- _ PHASE SUPPLIED BOX O --------- FUSED CONTROL G I CONDENSING DISCONNECT BOX ------------ UNIT 24-VOLT TERMINAL NOTES:1. Connect YN2-terminal as shown for proper operation. BLOCK 2. Some thermostats require a"C"terminal connection as shown. FURNACE 3. If any of the original wire,as supplied,must be replaced,use same type or equivalent wire. A9523C Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 6 820TA/821TA:Product Data o O O ,o, SEE NOTES:1,2,4,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 on the page following on the page following these figures these figures A03210 Fig. 1—Upflow Application-Vent Elbow Up A03208 Fig.4—Downflow Application-Vent Elbow Up then Left K7 O 'o' SEE NOTES:1,2,4,5,7,8,9 SEE NOTES:1,2,3,4,7,8,9 on the page following on the pages following these figures these figures A03211 Fig.2—Upflow Application-Vent Elbow Right A03209 Fig.5—Downflow Application-Vent Elbow Up a' O O SEE NOTES:1,2,4,7,8,9 on the page 1 following these figures SEE NOTES:1,2,4,7,8,9 on the page A03218 following these figures Fig.6—Horizontal Right Application-Vent Elbow Right Fig.3—Horizontal Left Application-Vent Elbow Left A032I3 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 7 820TA1821 TA:Product Data Ul W W i;i;:;iij .o I i i I I O I I i I ° I I OI � I o I l I I I ° SEE NOTES:1,2,4,5,7,8,9 on the page following these figures Fig. 10—Horizontal Left Application-Vent Elbow Up A03215 SEE NOTES:1,2,4,5,6,7,8,9 on the page following these figures A03207 Fig.7—Downflow Application-Vent Elbow Left then Up �! I SEE NOTES:1,2,4,5,7,8,9 on the page following these figures Fig.11—Horizontal Left Application-Vent Elbow Right A03216 •o• u�uT w SEE NOTES:1,2,3,4,5,7,8,9 p on the page following these figures. A03212 Fig.S—Downflow Application-Vent Elbow Up then Right _ I SEE NOTES:1,2,4,5,7,8,9 on the page Ili following these figures 0 219 Fig.12—Horizontal Right Application-Vent Elbow Left then p 1' I o O SEE NOTES: 1,2,4,5,7,8,9 on the page t following these figures SEE NOTES:1,2,4,5,7,8,9 I 3214 Fig.9—Horizontal Left Applications-Vent Elbow Right then 1Up Fig.13—Horizontal Right Application-Vent Elbow Left A02068 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 8 820TA/821TA:Product Data Venting Notes 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.I/NFPA 54. 2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4-in.(102 mm)single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit,required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180°apart. 9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120' apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. AIR DELIVERY—CFM (With Filter)* Air Delivery-CFM(With Filter)* COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Return5 With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See Notes 1 and 2.) 1� Unit Size: Clg/CF Switch settings External Static Pressure(ESP) 136045V14 Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 OFF OFF ON 620 560 520 455 410 355 305 255 See Note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 OFF ON ON 1020 955 930 890 840 805 755 715 645 490 Cooling ON OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 (SW2-8,7,6) ON OFF ON 1455 1390 1325 1255 1175 1085 1000 1 880 755 575 ON ON OFF 1 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON ON 1 1455 1390 1325 1255 1175 1085 1000 880 755 575 Maximum Clg Airflow2 1455 1390 1325 1255 1175 1085 1000 880 755 575 CF Switches VOF SW2-4 SW2-3 Low-Clg Default: OFF OFF 620 560 520 455 410 355 305 255 See Note 4 OFF ON 620 560 520 455 410 355 305 255 See Note 4 ON OFF 795 755 705 670 615 585 530 490 440 405 Low-Cooling ON ON 1020 955 930 890 840 805 755 715 645 490 (SW2-5,4,3) OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 ON OFF ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON OFF 1455 1390 1 1325 1255 1175 1085 1000 880 755 575 ON ON ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 Cont.Fan Default: OFF OFF OFF 620 560 520 455 410 355 305 255 See Note 4 OFF OFF ON 620 560 520 455 410 355 305 255 See Note 4 OFF I ON OFF 795 755 705 670 615 585 530 490 440 405 Continuous Fan OFF ON ON 1020 955 930 890 1 840 805E66-55, 715 645 490 ON OFF OFF 1020 955 930 890 840 805 715 645 490 (SW2-5,4,3) ON OFF ON 1020 955 930 890 840 805 715 645 490 ON ON OFF 1020 955 930 890 840 805 715 645 490 ON ON ON 1020 955 930 890 840 805 715 645 490 Heating High HeatAirflow3 915 860 825 790 735 700 610 550 450 (SW 1) Low Heat Airflow3 780 730 685 635 585 545 495 450 400 370 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 9 820TAI821TA:Product Data Air Delivery-CFM(With Filter)*(Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Return5 With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See Notes 1 and 2.) Unit Size: Cig/CF Switch settings External Static Pressure(ESP) 36070V14 Cig Switches: SW2-8 I SW 2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 .0 Clg Default: OFF OFF OFF 1155 1125 1095 1 1065 1035 1005 975 950 915 14 875 NOFFF ON 605 555 500 440 375 320 265 See Not 4 N OFF 775 735 690 650 600 550 500 450 40 365 N ON 980 950 915 880 845 810 775 735 5 655 Cooling F OFF 1155 1125 1095 1065 1035 1005 975 950 15 875 (SW2-8,7,6) F ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 N OFF 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 N ON 1505 1480 1455 1420 1380 1335 1250 11 1045 900 Airflow2 1505 1480 1455 1420 1380 1335 1250 1 5 1045 900 CIF Switches 2 SW2-3 Low-Clg Default: F OFF 605 555 500 440375 320 265See Note 4 F ON 605 555 500 440 375 320 265 See Note 4 N FF 775 735 690 650 600 550 50 450P405 365 OFF N 980 950 915 880 845 810 7 735 655 Low-Cooling ON OFF OF 1155 1125 1095 1065 1035 1005 75 950 875 (SW2-5,4,3) ON OFF ON 1376 1340 1310 1285 1260 1235 1210 1140 880 ON ON OFF 1505 1480 1455 1420 1380 1335 1250 1155 900 ON ON ON 1505 1480 1455 1420 1380 1335 1250 1155 10 900 Cont.Fan Default: OFF I OFF OFF 6 5 555 500 440 375 3 265 See Note 4 OFF OFF ON 60 555 500 440 375 20 265 See Note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 Continuous Fan OFF ON ON 980 950 915 880 845 810 775 735 695 655 (SW2-5,4,3) ON OFF OFF 1155 125 1095 1065 103 1005 975 950 915 875 ON OFF ON 1370 1 0 1310 1285 1 0 1235 1210 1140 1025 880 ON ON OFF 1370 13 1310 1285 60 1235 1210 1140 1025 880 ON ON ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 Heating High HeatAirflow3 1190 1160 1130 1100 1070 1045 1015 985 955 900 (SW1) Low HeatAirflow3 725 680 35 58 530 475 425 375 330 285 Unit Size: CIg/CF Switch settings xternal Static Pressure(ESP) 48070V17 Cig Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Cig Default: OFF OFF OFF 1600 1570 1535 1500 1465 1430 1400 1365 1335 1300 OFF OFF ON 590 520 44 65 300 235 See Note 4 OFF ON OFF 790 730 6 0 6 550 485 430 380 330 275 OFF ON ON 1025 980 30 88 835 785 735 690 635 590 Cooling ON OFF OFF 1230 1190 1150 1105 1065 1025 980 940 900 860 (SW2-8,7,6) ON OFF ON 1390 1355 1315 1280 1240 1200 1165 1125 1090 1055 ON ON OFF 1600 157 1535 1500 465 1430 1400 1365 1335 1300 ON ON ON 1855 1 0 1800 1770 1 0 1695 1645 16 00 1520 1415 Maximum Cig Airflow2 1855 30 1800 1770 174 1695 1645 1600 1520 1415 CIF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 590 520 440 365 300 235 See Note 4 OFF OFF ON 59 520 440 365 300 35 See Note 4 OFF ON OFF 7 0 730 670 610 550 4 5 430 380 330 275 OFF ON ON 025 980 930 880 835 78 735 690 635 590 Low-Cooling ON OFF OFF 1230 1190 1150 1105 1065 1025 980 940 900 860 (SW2-5,4,3) ON OFF ON 1390 1355 1315 1280 1240 1200 1165 1125 1090 1055 ON ON OF 1600 1570 1535 1500 1465 1430 400 1365 1335 1300 ON ON 1855 1830 1800 1770 1740 1695 1 5 1600 1520 1415 Cont.Fan Default: OFF OFF OFF 590 520 440 365 300 235 See Note 4 OFF OFF ON 590 520 440 365 300 235 See Note 4 OFF ON OFF 685 625 565 505 445 385 325 265 See Note 4 Continuous Fan OFF O ON 790 730 670 610 550 485 430 80 330 275 ON 9OPF OFF 790 730 670 610 550 485 430 38P 330 275 (SW2-5,4,3) ON OFF ON 790 730 670 610 550 485 430 38 330 275 ON ON OFF 790 730 670 610 550 485 430 380 t20 275 O ON ON 790 730 670 610 550 485 430 380 275Heating High HeatAirtlow 1375 1340 1300 1260 1225 1190 1155 1085 (SW1) Low HeatAirflow3 1235 1195 1155 1110 1070 1025 985 1 945 9 865 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 10 820TA/821TA:Product Data Air Delivery-CFM(With Filter)*(Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See Notes 1 and 2.) Unit Size: CIg/CF Switch settings External Static Pressure(ESP) 4809OV17 CIg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 Clg D fault: OFF OFF OFF 1560 1520 1485 1450 1415 1380 1340 1300 260 1115 OFF OFF ON 680 605 495 415 345 275 Se ote 4 OFF ON OFF 835 770 700 600 535 465 410 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Cooling ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 (SW2-8,7,6) ON OFF ON 1375 1335 1300 1260 1220 1175 11 1075 1010 955 ON ON OFF 1560 1520 1485 1450 1415 1380 40 1300 1260 1115 ON ON ON 1640 1605 1570 1540 1505 1470 1435 1390 1325 1110 aximum CIg Airflow2 1640 1605 1570 1540 1505 1470 1435 1390 1325 1110 CF Switches SW SW2-4 SW2-3 Low-CIg Default: OFF OFF OFF 680 605 495 415 345 5 See Note 4 OFF OFF ON 680 605 495 415 345 275 See Note 4 OFF N OFF 835 770 700 600 535 465 410 350 285 240 Low-Cooling OFF ON 1035 980 930 870 795 720 665 605 555 505 Low-Cooling ON OF OFF 1210 1165 1125 1080 10 975 905 845 790 740 ON OFF ON 1375 1335 1300 1260 20 1175 1125 1075 1010 955 ON ON OFF 1560 1520 1485 1450 1415 1380 1340 1300 1260 1115 ON ON N 1640 1605 1570 1540 1505 1470 1435 1390 1325 1110 Cont.Fan Default: OFF OFF OF 680 605 495 41 345 275 See Note 4 OFF OFF ON 680 605 495 5 345 275 See Note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 Continuous Fan OFF ON ON 035 980 930 870 795 720 665 605 555 505 (SW2-5,4,3) ON OFF OFF 1 0 1165 112 1080 1030 975 905 845 790 740 ON OFF ON 137 1335 13 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 N 1520 85 1450 1415 1380 1340 1300 1260 1115 ON 1 ON ON 1560 1520 1485 1450 1415 1380 1340 1300 1260 1 1115 eating High Heat 1400 1 0 1325 1285 1245 1200 1155 1110 1045 995 H (SW1) Low HeatAirflow3 1035 98 930 870 795 720 665 605 555 505 Unit Size: Clg/CF Switch settings External Static Pressure(ESP) 6009OV21 CIg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CIg Default: OFF OFF OFF 198 1935 188 1835 1785 1735 1685 1630 1583 1532 OFF OFF ON 8 755 650 545 445 350 235 See Note 4 OFF ON OFF 85 1000 910 830 735 655 565 485 405 310 OFF ON ON 255 1180 1105 25 950 870 790 715 640 570 Cooling ON OFF OFF 1425 1355 1290 12 1150 1085 1015 940 870 800 (SW2-8,7,6) ON OFF ON 1630 1575 1515 1455 1395 1330 1270 1210 1155 1090 ON ON OF V700 1935 1885 1835 1785 1735 1685 1630 1583 1532 ON ON N 2055 2010 1960 915 1870 1820 1775 1715 1640 Maximum Clg Ai w2 2055 2010 1960 19 1870 1820 1775 1715 1640 CF Switches SW2-5 SW2-4 SW2-3 Low-CIg Default: OFF OFF OFFK755 650 545 445 350 235 See Note 4 OFF O ON 455 345 225 See Note 4 OFF N OFF 860 650 545 445 3 235 See Note 4 Low-Cooling OFF ONON 1085910 830 735 65 565 485 405 310 (SW2-5,4,3) ON OFF OFF 1255 11051025 950 870 790 715 640 570 OOFF ON 1425 1290 1220 1150 1085 015 940 870 800 ON OFF 1630 1575 1515 1455 1395 1330 1 70 1210 1155 1090 ON ON ON 1985 1935 1885 1835 1785 1735 169k 1630 1583 1532 Cont.Fan Default: OFF OFF OFF 860 755 650 545 445 350 235 See Note 4 OFF OFFKFF 700 575 455 345 225 See Note 4 OFF ON 860 755 650 545 445 350 235 ee Note 4 Co/ntinF)an OFF ON1085 1000 910 830 735 655 565 48 405 310 ( ON OFF 1255 1180 1105 1025M1370 870 790 715 640 570 ON OFF1255 1180 1105 1025870 790 715 40 570 ON ON OFF 1255 1180 1105 1025870 790 715 0 570 ON ON ON 1255 1180 1105 1025870 790 715 64 570 Heating High HeatAirflow3 1830 1775 1725 16751570 1520 1465 1410 360 (SW1) Low HeatAirflow3 1600 1540 1485 14301315 1255 1195 1140 10 0 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 11 820TA/821TA:Product Data Air Delivery-CFM(With Filter)*(Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Return5 With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See Notes 1 and 2.) Unit Size: CIg/CF Switch settings External Static Pressure(ESP) 6611OV21 C Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1 0.8 r 0.9 1 1.0 CI efault: OFF OFF OFF 2055 2000 1950 1900 1840 1790 1740 1 16X 1 1625 1 1565 OFF OFF ON 855 755 See Note 4 OFF ON OFF 1060 985 875 800 700 26e Note 4 OFF ON ON 1250 1180 1095 1025 925 860 77 1 715 See Note 4 Cooling ON OFF OFF 1445 1380 3320 1235 1175 1100 35 955 900 825 (SW2-8,7,6) ON OFF ON 1685 1630 1560 1505 1445 1375 1320 1265 1195 1140 ON ON OFF 2055 2000 1950 1900 1840 179 1740 1675 1625 1565 N ON ON 2465 2415 2365 2305 2230 21 2045 1925 1805 1655 ximum CIg Airflow2 2465 2415 2365 23 55 2230 40 2045 1925 1805 1655 CF Switches SW2- SW2-4 SW2-3 Low-Clg Default: OFF 1, OFF OFF 855 755 See Note 4 OFF OFF ON 640 540 See Note 4 OFF ON OFF 855 755 See Note 4 Low-Cooling OFF ON 1060 985 875 800 700 See Note 4 (SW2-5,4,3) ON O OFF 1250 1180 1095 1025 925 860 775 715 See Note 4 ON OF ON 1445 1380 1320 1235 1175 1100 1035 955 900 825 ON ON OFF 1685 1630 1560 1505 1445 1375 1320 1265 1195 1140 ON ON ON 2055 2000 1950 190 1840 1790 1740 1675 1625 1565 Cont.Fan Default: OFF OFF FF 855 755 See Note 4 OFF OFF 640 540 See Note 4 OFF ON OF 855 755 See Note 4 Continuous Fan OFF ON ON 1060 985 875 800 700 See Note 4 OF (SW2-5,4,3) ON F OFF 1250 1180 109 1025 925 860 775 715 See Note 4 ON OFF ON 445 1380 13 0 1235 1175 1100 1035 955 900 825 ON ON OFF 1 45 1380 20 1235 1175 1100 1035 955 900 825 ON ON ON 14N 1380 1320 1235 1175 1100 1035 955 900 825 Heating High HeatAirflow3 2105 2055 2005 1955 1895 1850 1795 1735 1665 1580 (SW1) Low HeatAirflow3 1740 N1 60 1 1620 1560 1505 1 1440 1385 1325 1260 1205 Unit Size: CIg/CF Switch settings External Static Pressure(ESP) 66135V24 CIg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 1 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 210Y 050 1995 1940 1880 1820 1765 1 1705 1650 1590 OFF OFF ON 990 885 X80 665 570 See Note 4 OFF ON OFF 80 1090 9 900 815 715 635 555 1 475 400 OFF ON ON 1355 1270 119N 1105 1020 940 855 775 1 700 630 Cooling ON OFF OFF 1535 1465 1395 N, 1320 1245 1165 1095 1025 945 875 (SW2-8,7,6) ON OFF OV 1735 1670 1605 1535 1470 1405 1335 1270 1205 1140 ON ON OFF 2105 2050 1995 40 1880 1820 1765 1705 1650 1590 ON ON ON 2280 2225 2175 21 2065 2010 1955 1905 1850 1800 Maximum CIg owe 2360 2310 2265 2215 2160 2115 2060 2010 1960 1870 CF Switches SW2-5 SW2 SW2-3 Low-CIg Default: OFF O OFF 990 885 780 665 70 See Note 4 OFF FF ON 800 670 540 410 2 See Note 4 OFF ON OFF 990 885 780 665 570 See Note 4 OFF ON ON 1180 1090 995 900 815 715 635 555 475 400 Low-Cooling OFF OFF 1355 1270 1190 1105 1020 40 855 775 700 630 (SW2-5,4,3) ON OFF ON 1535 1465 1395 1320 1245 1 5 1095 1025 945 875 ON ON OFF 1735 1670 1605 1535 1470 140 1335 1270 1205 1140 ON ON ON 2105 2050 1995 1940 1880 1820 1765 1705 1650 1590 Con7FanDlt: OFF OFF OFF 740 605 470 360 255 See NoteOFF OFF ON 740 605 470 360 255 See Note 4 OFF ON OFF900 775 650 525 400 ee Note 4 Cn OFF ON ON 1080 980 885 785 680 E95 510 430 345 260 ON OFF OFF 1080 980 885 785 680 510 0 345 260 ( ON OFF ON 1080 980 885 785 680 510 43 345 260 ON ON OFF 1080 880 885 785 680 510 430 345 260 ON ON ON 1080 980 885 785 680 510 430 345 260 Heating High HeatAirflow3 2130 2075 2020 1970 1910 1855 1805 1745 16 1630 (SW1) Low HeatAirflow3 1855 1795 1730 1670 1 1605 1 1545 1 1480 1420 1360 1300 Notes following table. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 12 820TA/821TA:Product Data 1.Nominal 350 CFM/ton cooling airflow is delivered with SW 1-5 and SW2-2 set to OFF. Set both SW 1-5 and SW2-2 to ON for+7%airflow(nominal 370 CFWton). Set SW 1-5 to ON and SW2-2 to OFF for+15%airflow(nominal 400 CFM/ton). Set SW2-2 to ON and SWI-5 to OFF for-7%airflow(nominal 325 CFM/ton). The above adjustments in airflow are subject to motor horsepower range/capacity. This applies to Cooling and Low-Cooling airflow,but does not affect continuous fan airflow. 2.Maximum cooling airflow is achieved when switches SW2-6,SW2-7,SW2-8 and SW 1-5 are set to ON,and SW2-2 is set to OFF. 3.All heating CFM's are when comfort/efficiency adjustment switch(SW 1-4)is set to OFF 4.Ductwork must be sized for high-heating CFM within the operational range of ESP.Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP. 5.AII airflows on 21"casing size furnaces are 5%less on side return only installations. 6.Side returns for 24.5"casing sizes require two sides,or side and bottom,to allow sufficient airflow at the return of the furnace. 7.Airflows over 1800 CFM require bottom return,two-side return,or bottom and side return or excessive watt draw may result.A minimum filter size of 20 x 25"(508 x 635 mm)is required. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 13 820TA/821TA:Product Data GUIDE SPECIFICATIONS Gas Furnace Heat Exchangers 820TA/821 TA • Heat exchangers shall be a 4-Pass 20 gage aluminized steel of fold-and-crimp sectional design when applied operating under SYSTEM DESCRIPTION negative pressure. • Furnish a fixed capacity gas-fired furnace for Controls use with natural gas or propane (factory authorized conversion kit Control shall include a micro-processor based integrated electronic required for propane);furnish cold air return plenum. control board with at least 11 service troubleshooting codes displayed QUALITY ASSURANCE via diagnostic flashing enhanced LED light on the control,a self-test • Unit will be designed, tested and constructed to the current ANSI Z feature that checks all major functions of the furnace within one 21.47/CSA 2.3 design standard for gas-fired central furnaces. minute, and a replaceable automotive-type circuit protection fuse. • Unit will be 3rd party certified by CSA to the current ANSI Z Multiple operational settings available including, separate blower 21.47/CSA 2.3 design standard for gas-fired central furnaces. speeds for low heat, high heat, low cooling, high cooling and • Unit will carry the CSA Blue Star®label. continuous fan. Continuous fan speed may be adjusted from the • Unit efficiency testing will be performed per the current DOE test thermostat. Cooling airflow will be selectable between 350 or 400 procedure as listed in the Federal Register. CFM per ton of air conditioning.Features will also include temporary • Unit will be certified for capacity and efficiency and listed in the latest reduced airflow in the cooling mode for improved dehumidification AHRI Consumer's Directory of Certified Efficiency Ratings. when a control or Thermidistat' is selected as the thermostat. • Unit shall carry the current Federal Trade Commission Energy Guide OPERATING CHARACTERISTICS efficiency label. Heating Capacity shall be Btuh input; Btuh DELIVERY STORAGE AND HANDLING output capacity. • Unit shall be shipped as single package only and is stored and handled Fuel Gas Efficiency shall be 80%AFUE. per unit manufacturer's recommendations. Air delivery shall be CFM minimum at 0.50 in.W.C. WARRANTY(for inclusion by specifying engineerl external static pressure. • U.S.only.Warranty certificate available upon request. Dimensions shall be: depth in. (mm);width in. (mm); height in. (mm). (casing only). Height shall Products be in. (mm). with A/C coil and in. (mm) EQUIPMENT overall with plenum. • Components shall include: slow-opening two stage gas valve to ELECTRICAL REQUIREMENTS reduce ignition noise, regulate gas flow, with electric switch gas Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal). shut-off; flame proving sensor, hot surface igniter, pressure switch Minimum wire size shall be AWG;maximum fuse size or assembly, flame rollout switch, blower and inducer assembly, 40va circuit breaker shall be Amps. transformer;low-voltage(heating)(heating/cooling)thermostat. SPECIAL FEATURES Blower Wheel and Blower Motor • Refer to section of the product data sheet identifying accessories and • Galvanized blower wheel shall be centrifugal type, statically and descriptions for specific features and available enhancements. dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed bearings,of hp,and shall be multiple-speed direct drive.Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission. Filters • Furnace may have reusable-type filters. Filter shall be (x) in. (mm). An accessory high efficiency Media Filter is available as an option. Media Filter. Casing • Casing shall be of.030 in.(.76 mm)thickness minimum,pre-painted steel. Two Speed Inducer Motor • Two Speed Inducer motor shall be soft mounted to reduce vibration transmission. Draft Safeguard Switch • Draft Safeguard Switch (blocked vent safeguard) shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe. ©2020 Carrier.All rights reserved Edition Date:09/20 Catalog No:PDS820TA-03 A Carrier Company Replaces:PDS820TA-02 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 14 Residential Mechanical Application For Instruction/Checklist,please click here Site Address: 8413 179th pl ne Project Name: I Husby Project Valuation: 2146 Preferred Contact: Owner Contractor Project Description: Replace existing gas furnace with a new gas furnace in the same location, located in the garage Owner Details Owner Name: Leanne Husby Home No.: 425-870-8412 Email Address: Lovesthebible@outlook.com Cell No.: Mailing Address: 8413 179th pl NE City: arlington State: wa Zip: 98223 Contractor Details Contractor Name: Day and Nite Plumbing and I Office No.: 425-775-6464 Email Address: georgia.paschen@dayandnit Cell No.: Mailing Address: 116614 13'th ave w City: Lynnwood State: I WA Zip: 98037 L&I Contractor License Number: I DAYNINP752JH Expiration Date: 04/10/2027 Proposed Piping Material: O CSST O Brass 0 Black Steel Galvanized Steel Other Proposed Piping Size: 1/2" 5/8" 3/4" III 1 1/2" 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Units Additional Plan Review fees Air Cond. Unit< or equal to 100Btu/h Air Cond. Unit>100Btu/h Air Cond. Unit>500Btu/h Air Handling Units Base Mechanical Fee Boiler<100Btu/h>3hp Boiler>1 million Btu/h<50hp Boiler>1.5 million Btu/h<50hp Boiler>100Btu/h 3-15hp Boiler>500Btu/h 15-30hp Commercial Hoods -Type I Commercial Hoods -Type II Diffusers Dryer Ducting Ductwork(drawings required) Evaporative Coolers ExhaustNentilation Fans Fireplace/Insert/Stove Forced Air Heat< or equal to 100 Btu/h 1 Forced Air Heat>100 Btu/h Gas Clothes Dryer Gas Fired Air Conditioning Unit<or equal to 100 Btu/h Gas Fired Air Conditioning Unit>100 Btu/h Gas Fired Air Conditioning Unit>500 Btu/h III Gas Piping<or equal to 5 units Gas Piping for each additional unit> 5 Heat Exchangers Heat Pump-Condensing Unit Hot Water Heat Coils Miscellaneous Appliance - regulated by mechanical code, not otherwise specified Package Units< or equal to 100btu/> 100 Btu Range/Cook top-Gas Fired Refrigeration Unit < or equal to 100Btu/h Refrigeration Unit>100Btu/h Refrigeration Unit>500Btu/h Re-inspection fee Residential Range Hood Unit Heaters < or equal to 100 Btu/h Unit Heaters >100 Btu/h Variable Air Volume Boxes (part of air conditioning system) 1 Wall Heaters - Gas Fired Water Heater- Gas Fired I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Print Name: I Georgia Paschen Date: 03/11/2026