Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17520 HIGHLAND VIEW DR_PA26-0189_2026
12' 240 w Wd Dk 120 s.f. 0 o e �s 12' AC UNIT HERE 17520 HIGHLAND VIEW DRIVE C u72 s.i. 11' FURNACE HERE, IN GARAGE tr i Fr G $50 s t i� h 11 11' 22' *M9C96 & *C9C96 TWO-STAGE GAS FURNACES (Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace) (Type FSP CATEGORIE IV Direct ou four a air souffl' non direct) These furnaces comply with requirements RECOGNIZE THIS SYMBOLAS A SAFETY PRECAUTION. embodied in the American National Standard/National Standard of Canada CUS 'NOTE: Please contact your distributor or our website for ANSI Z21.47-CSA-2.3 Gas Fired Central (OTT $' the applicable Specification Sheet referred to in this manual. Furnaces. 1 I ntertek A INSTALLER: Affix all manuals adjacent to the unit. WARNING ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL,ADJUST,SERVICE OR REPAIR (HEREINAFTER, "SERVICE") THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD As a professional installer you have an obligation to know SERVICE THE EQUIPMENT.THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY the product better than the customer.This includes all safety INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE precautions and related Items. PROCEDURES. IF YOU SERVICE THIS UNIT,YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. IN ADDITION,IN JURISDICTIONS Prior to actual installation,thoroughly familiarize yourself with THAT REQUIRE ONE OR MORE LICENSES TO SERVICE THE EQUIPMENT SPECIFIED IN THIS this Instruction Manual. Pay special attention to all safety MANUAL,ONLY LICENSED PERSONNEL SHOULD SERVICE THE EQUIPMENT. IMPROPER warnings. Often during installation or repair it is possible to INSTALLATION,ADJUSTMENT,SERVICING OR REPAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL, OR ATTEMPTING TO INSTALL, ADJUST, SERVICE OR REPAIR THE place yourself in a position which is more hazardous than EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER TRAINING MAY RESULT IN when the unit Is In operation. PRODUCT DAMAGE,PROPERTY DAMAGE,PERSONAL INJURY OR DEATH. Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer 90% HEX in its safe use. Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety practices...follow them. The precautions listed in this Installation Manual are intended _ DO NOT LIFT as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content PRODUCT USING of this manual, the precautions listed here take precedence. HEAT EXCHANGER 19001 Kermier Rd. Waller, Tx 77484 www.goodmanmfg.com•www.amana-hac.com ©2021 Goodman Manufacturing Company, L.P. 08/2021 7A Aana is a registered trademark of Maytag Corporation or its related companies and is used under license. T All rights reserved. Table of Contents SAFETY CONSIDERATIONS.............................................. 3 PRODUCT DESCRIPTION .................................................... 5 PRODUCT APPLICATION..................................................... 5 LOCATION REQUIREMENTS&CONSIDERATIONS................. 6 COMBUSTION &VENTILATION REQUIREMENTS............... 10 INSTALLATION POSITIONS................................................. 10 HORIZONTAL APPLICATIONS&CONSIDERATIONS.............. 11 PROPANE GAS/HIGH ALTITUDE INSTALLATIONS.................. 11 CONDENSATE DRAIN LINES&DRAIN TRAP........................ 18 ELECTRICAL CONNECTIONS............................................. 23 GAS SUPPLY AND PIPING.................................................. 26 CIRCULATING AIR& FILTERS........................................... 29 STARTUP PROCEDURE&ADJUSTMENT.............................. 31 AIRFLOW TABLES ............................................................ 34 NORMAL SEQUENCE OF OPERATION ............................... 39 OPERATIONAL CHECKS..................................................... 40 SAFETY CIRCUIT DESCRIPTION.......................................... 41 TROUBLESHOOTING .......................................................... 41 MAINTENANCE .................................................................. 42 BEFORE LEAVING AN INSTALLATION.................................. 42 STATUS CODES ................................................................ 44 TROUBLESHOOTING CHART............................................. 45 WIRING DIAGRAM............................................................ 46 START UP CHECKLIST...................................................... 48 2 Always install a furnace to operate within the furnace's AWARNING intended temperature-rise range with a duct system which FIRE OR EXPLOSION HAZARD has external static pressure within the allowable range, as specified on the furnace rating plate and OPERATIONAL Failure to follow the safety warnings exactly could result CHECKS section of these instructions. in serious injury,death or property damage. When a furnace is installed so that supply ducts carry air cir- culated by the furnace to areas outside the space containing Never test for gas leaks with an open flame. the furnace, the return air shall also be handled by duct(s) Use a commercially available soap solution made sealed to the furnace casing and terminating outside the specifically for the detection of leaks to check all space containing the furnace. connections.A fire or explosion may result causing property damage,personal injury or loss of life. A CAUTION AAVERTISSEMENT FROZEN AND BURST WATER PIPE HAZARD FAILURE TO PROTECT AGAINST THE RISK OF FREEZING MAY RESULT IN RISQUE D'INCENDIE OU D'EXPLOSION PROPERTY DAMAGE. SPECIAL PRECAUTIONS MUST BE MADE IF INSTALLING FURNACE IN AN Si les consignes de securite ne sont pas suivies a la lettre, AREA WHICH MAY DROP BELOW FREEZING.THIS CAN CAUSE IMPROPER cela peut entrainer la mort,de graves blessures ou des OPERATION OR DAMAGE TO EQUIPMENT. IF THE FURNACE dommages materiels. ENVIRONMENT HAS THE POTENTIAL OF FREEZING,THE DRAIN TRAP AND DRAIN LINE MUST BE PROTECTED.THE USE OF ACCESSORY DRAIN TRAP Ne jamais verifier la presence de fuites de gaz au moyen HEATERS,ELECTRIC HEAT TAPE AND/OR RV ANTIFREEZE IS d'une flamme nue.Verifier tous les raccords en utilisant RECOMMENDED FOR THESE INSTALLATIONS. une solution savonneuse Commerciale congue specialement pour la detection de fuites. Un incendie ou A gas-fired furnace for installation in a residential garage une explosion risque de se produire,ce qui peut entrainer must be installed as specified in the LOCATION REQUIRE- la mort,des blessures ou des dommages materiels. MENTS AND CONSIDERATIONS section of this manual. This furnace may be used as a construction site heater only SAFETY CONSIDERATIONS if certain conditions are met. These conditions are listed in the PRODUCT APPLICATION section of this manual. Adhere to the following warnings and cautions when install- ing, adjusting, altering, servicing, or operating the furnace. AWARNING To ensure proper installation and operation,thoroughly read this manual for specifics pertaining to the installation and TO PREVENT PERSONAL INJURY OR DEATH DUE TO IMPROPER application Of this product. INSTALLATION,ADJUSTMENT,ALTERATION,SERVICE OR MAINTENANCE, REFER TO THIS MANUAL. FOR ADDITIONAL ASSISTANCE OR This furnace is manufactured for use with natural gas. It INFORMATION,CONSULT A QUALIFIED INSTALLER,SERVICER AGENCY OR may be field converted to operate on L.P. gas by using the THE GAS SUPPLIER. appropriate L.P.conversion kit listed in the PROPANE GAS/ HIGH ALTITUDE INSTALLATIONS section of this manual A WARNING Install this furnace only in a location and position as specified IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED in LOCATION REQUIREMENTS & CONSIDERATIONS EXACTLY,A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY section and INSTALLATION POSITIONS section of this DAMAGE,PERSONAL INJURY OR LOSS OF LIFE. manual. —DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. Provide adequate combustion and ventilation air to the fur- —WHAT TO DO IF YOU SMELL GAS: nace as specified in COMBUSTION & VENTILATION AIR DO NOT TRY TO LIGHT ANY APPLIANCE. REQUIREMENTS section of this manual. DO NOT TOUCH ANY ELECTRICAL SWITCH;DO NOT USE ANY PHONE IN YOUR BUILDING. Combustion products must be discharged to the outdoors. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBORS PHONE. FOLLOW THE GAS SUPPLIERS INSTRUCTIONS. Connect this furnace to an approved vent system only, as IF YOU CANNOT REACH YOUR GAS SUPPLIER,CALL THE FIRE specified in VENT/FLUE PIPE & COMBUSTION AIR PIPE DEPARTMENT. section of this manual. —INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED Never test for gas leaks with an open flame. Use a com- INSTALLER,SERVICE AGENCY OR THE GAS SUPPLIER. mercially available soap solution made specifically for the detection of leaks to check all connections, as specified in GAS SUPPLY AND PIPING section of this manual. 3 A WARNING A WARNING HEATING UNIT SHOULD NOT BE UTILIZED WITHOUT REASONABLE, SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, ROUTINE,INSPECTION,MAINTENANCE AND SUPERVISION. IF THE TURN OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE BUILDING IN WHICH ANY SUCH DEVICE IS LOCATED WILL BE VACANT, FURNACE BEFORE TURNING OFF THE ELECTRICAL SUPPLY. CARE SHOULD BE TAKEN THAT SUCH DEVICE IS ROUTINELY INSPECTED, MAINTAINED AND MONITORED. IN THE EVENT THAT THE BUILDING A WARNING MAYBE EXPOSED TO FREEZING TEMPERATURES AND WILL BE VACANT, ALL WATER-BEARING PIPES SHOULD BE DRAINED,THE BUILDING SHOULD POSSIBLE PROPERTY DAMAGE,PERSONAL INJURY OR DEATH DUE TO BE PROPERLY WINTERIZED,AND THE WATER SOURCE CLOSED.IN THE FIRE,EXPLOSION,SMOKE,SOOT,CONDENSATION,ELECTRICAL SHOCK EVENT THAT THE BUILDING MAY BE EXPOSED TO FREEZING OR CARBON MONOXIDE MAY RESULT FROM IMPROPER INSTALLATION, TEMPERATURES AND WILL BE VACANT,ANY HYDRONIC COIL UNITS REPAIR OPERATION,OR MAINTENANCE OF THIS PRODUCT. SHOULD BE DRAINED AS WELL AND, IN SUCH CASE,ALTERNATIVE HEAT ELECTROSTATIC DISCHARGE (ESD) SOURCES SHOULD BE UTILIZED. PRECAUTIONS A WARNING NOTE: Discharge your body's static electricity before TO PREVENT POSSIBLE PROPERTY DAMAGE,PERSONAL INJURY OR touching unit.An electrostatic discharge can adversely affect DEATH DUE TO ELECTRICAL SHOCK,THE FURNACE MUST BE LOCATED TO electrical components. PROTECT THE ELECTRICAL COMPONENTS FROM WATER. Use the following precautions during furnace installation and servicing to protect the integrated control module from Drain trap must be primed at time of installation. Trap is in- damage. By putting the furnace, the control, and the person ternally partitioned; add water to both inlet ports until water at the same electrostatic potential, these steps will help appears at both sides of the outlet opening. Failure to prime avoid exposing the integrated control module to electrostatic trap at time of installation may have a negative effect on discharge. This procedure is applicable to both installed and combustion quality and pressure switch action. non-installed (ungrounded)furnaces. 1. Disconnect all power to the furnace. Do not touch the integrated control module or any wire connected to the SHIPPING INSPECTION control prior to discharging your body's electrostatic All units are securely packed in shipping containers tested charge to ground. according to International Safe Transit Association specifica- 2. Firmly touch a clean, unpainted, metal surface of the tions. The carton must be checked upon arrival for external furnaces near the control. Any tools held in a person's damage. If damage is found, a request for inspection by hand during grounding will be discharged. carrier's agent must be made in writing immediately. 3. Service integrated control module or connecting The furnace must be carefully inspected on arrival for damage wiring following the discharge process in step 2. Use caution not to recharge your body with static electricity; and bolts or screws which may have come loose in transit. (i.e., do not move or shuffle your feet, do not touch In the event of damage the consignee should: ungrounded objects,etc.). If you come in contact with 1. Make a notation on delivery receipt of any visible an ungrounded object, repeat step 2 before touching damage to shipment or container. control or wires. 2. Notify carrier promptly and request an inspection. 4. Discharge your body to ground before removing a new 3. With concealed damage, carrier must be notified as control from its container. Follow steps 1 through 3 if soon as possible - preferably within five days. installing the control on a furnace. Return any old or 4. File the claim with the following support documents new controls to their containers before touching any within a nine month statute of limitations. ungrounded object. • Original or certified copy of the Bill of Lading, or indemnity bond. TO THE INSTALLER • Original paid freight bill or indemnity in lieu thereof. Before installing this unit, please read this manual thoroughly • Original or certified copy of the invoice, showing to familiarize yourself with specific items which must be ad- trade and other discounts or reductions. hered to, including but not limited to: unit maximum external • Copy of the inspection report issued by carrier's static pressure,gas pressures,BTU input rating,proper elec- representative at the time damage is reported to trical connections, circulating air temperature rise, minimum carrier. or maximum CFM, and motor speed connections. The carrier is responsible for making prompt inspection of AWARNING damage and for a thorough investigation of each claim. The distributor or manufacturer will not accept claims from dealers TO PREVENT PROPERTY DAMAGE,PERSONAL INJURY OR DEATH DUE TO for transportation damage. FIRE,DO NOT INSTALL THIS FURNACE IN A MOBILE HOME,TRAILER,OR RECREATIONAL VEHICLE. 4 DANGERADANGERA PELIGRO 0& oes 0& CARBON MONOXIDE POISONING HAZARD RIESGO DE INTOXICACION POR MONOXIDO DE CARBONO RISQUE D'EMPOISONNEMENTAU MONOXYDE DE CARBONE Special Warning for Installation of Furnace or Air Handling Units in Advertencia especial para la instalaci6n de calentadores 6 manejadoms Advertencia especial Para la instalaci6n de calentadores 6 manejadoms Enclosed Areas such as Garages,Utility Rooms or Parking Areas de afire en areas cerradas como estacionamientos 6 cuartos de servicio. de aire en areas cerradas como estacionamientos 6 cuartos de servicio. Carbon monoxide producing devices(such as an automobile,space Los equipos 6 aparatos que producen mon6xido de carbono Avertissement special au sujet de('installation d'appareils de hauffage heater,gas water heater,etc.)should not be operated in enclosed areas (tal coma autom6vi,calentador de gas,calentador de agua por medio de ou de traitement d'air clans des endroits clos,tets les garages,les locaux such as unventilated garages,utility rooms or parking areas because of d'entretien et les stationnements.Evitez de mettre en marche les the clan er of carbon monoxidepoisoning resulting from the exhaust gas,etc)no deben ser operados en areas cerradas debido al riesgo g [CO)( )P g g de envenenamiento por mon6xido de carbono(CO)que resulta de las appareils produisant du monoxyde de carbone(tels que les automobile, emissions.If a furnace or air handier is installed in an enclosed area such les appareils de chauffage autonome,etc.)clans des endroits non as a garage,utility room or parking area and a carbon monoxide producing emisiones de gases de combustion.Si el equipo 6 aparato se opera en device is operated therein,there must be adequate,direct outside dichas areas,debe existir una adecuada ventilaci6n directa al exterior. ventiles tels que les d'empoisonnement au monoxyde de carbone.Si vous ventilation. Este ventilaci6n es necesari para evitar el peligro the envenenamiento devez faire fonctionner ces appareils clans un endroit clos,assures-vous This ventilation is necessary to avoid the danger of CO poisoning which por CO,que puede ocurrir si un dispositivo que produce mon6xido qu'il y ait une ventilation directe provenant de 1'exterier. can occur if a carbon monoxide producing device continues to operate in de carbono sigue operando en el lugar cerrado. Cette ventilation est necessaire pour eviter le danger d'intoxication the enclosed area.Carbon monoxide emissions can be(re)circulated Las emisiones de mon6xido de carbono pueden circular a traves au CO pouvant survenir si un appareil produisant du monoxyde throughout the structure if the furnace or air handler is operating in any del aparato cuando se opera en cualquier modo. de carbone continue de fonctionner au sein de la zone confinee. mode. CO can cause serious illness including permanent brain El mon6xido de carbono puede causar enfermedades severas Les emissions de monoxyde de carbone peuventetre recircules clans les damage or death. B10259-216 como dano cerebral permanente 6 muerte. B10259-216 endroitsclos,si I'appareil de chauffage ou de traitement d'air sons en marche. Le monoxyde de carbone peut causer des maladies graves telles que des dOmmage5 permanents au cerveau et meme la mort. B10259-216 PRODUCT DESCRIPTION It must not be used as a "make-up" air unit. • It must be installed as a two-pipe system for FEATURES combustion air. The *M9C96 furnace may be installed upflow or horizon- All other warranty exclusions and restrictions apply tally with left or right side down. The *C9C96 furnace may This furnace is an ETL dual-certified appliance and be installed downflow or horizontally with left or right side is appropriate for use with natural or propane gas down.*M9C96&*C9C96 two-stage gas furnaces features a (NOTE: If using propane, a propane conversion kit multi-speed ECM indoor fan motor, two heating inputs (W1 is required). &W2), two cooling inputs (Y1/Y&Y2)and a two stage gas Dual certification means that the combustion air inlet pipe is valve.A single stage heating thermostat may also be used optional and the furnace can be vented as a: in conjunction with timed transition to high fire by the furnace Non-direct vent (single pipe) central forced air integrated control board. furnace in which combustion air is taken from the PRODUCT APPLICATION installation area or from air ducted from the outside or, This furnace is primarily designed for residential home-heat- Direct vent (dual pipe) central forced air furnace ing applications. It is NOT designed or certified for use in in which all combustion air supplied directly to the mobile homes, trailers or recreational vehicles. Neither is it furnace burners through a special air intake system designed or certified for outdoor applications. The furnace outlined in these instructions. must be installed indoors (i.e., attic space, crawl space, or This furnace may be used as a construction site heater ONLY garage area provided the garage area is enclosed with an if all of the following conditions are met: operating door). The vent system is permanently installed per these This furnace can be used in the following non-industrial installation instructions. commercial applications: A room thermostat is used to control the furnace. Fixed jumpers that provide continuous heating Schools, Office buildings, Churches, Retail stores, Nursing CANNOT be used and can cause long term homes, Hotels/motels, Common or office areas equipment damage. Bi-metal thermostats, or any thermostat affected by vibration must not be used In such applications, the furnace must be installed with the during construction. following stipulations: • It must be installed per the installation instructions provided and per local and national codes. • It must be installed indoors in a building constructed on site. • It must be part of a ducted system and not used in a free air delivery application. 5 • Return air ducts are provided and sealed to the The rated heating capacity of the furnace should be greater furnace. than or equal to the total heat loss of the area to be heated. • A return airtemperature range between 60°F(161C) The total heat loss should be calculated by an approved and 80°F (27°C) is maintained. method or in accordance with "ASHRAE Guide"or"Manual • MERV 11 (Example P/N AMP-11-2025-45) air J-Load Calculations" published by the Air Conditioning Con- filter(s) are installed in the system and inspected tractors of America. daily and replaced as needed during construction A copy of the CAN/CSA B149.1-15 Installation Codes can and upon completion of construction. also be obtained from: • The input rate and temperature rise are set per the CSA International furnace rating plate. 178 Rexdale Boulevard • The furnace must be installed as a two pipe system, Etobicoke, Ontario, Canada M9W 1 R3 using 100% outside air for combustion during construction. • The furnace heat exchanger, components, LOCATION REQUIREMENTS duct system, air filters and evaporator coils are & CONSIDERATIONS thoroughly cleaned following final construction clean up by a qualified person. Follow the instructions listed below and the guidelines provided • All furnace operating conditions (including ignition, in the Combustion and Ventilation Air Requirements section input rate,temperature rise and venting)are verified when selecting a furnace location. by a qualified person according to these installation instructions. A WARNING • Furnace doors must be in place on the furnace while POSSIBLE PROPERTY DAMAGE,PERSONAL INJURY OR DEATH DUE TO the furnace is operating in any mode. FIRE,EXPLOSION,SMOKE,SOOT,CONDENSATION,ELECTRICAL SHOCK • Damage or repairs due to failure to comply with OR CARBON MONOXIDE MAY RESULT FROM IMPROPER INSTALLATION, these requirements are not covered under the REPAIR OPERATION,OR MAINTENANCE OF THIS PRODUCT. warranty. NOTE: The Commonwealth of Massachusetts requires A WARNING that the following additional requirements must also be met: TO PREVENT POSSIBLE EQUIPMENT DAMAGE,PROPERTY DAMAGE, • Gas furnaces must be installed by a licensed PERSONAL INJURY OR DEATH,THE FOLLOWING BULLET POINTS MUST BE plumber or gas fitter. OBSERVED WHEN INSTALLING THIS UNIT. • A T-handle gas cock must be used. Centrally locate the furnace with respect to the • If the unit is to be installed in an attic,the passageway proposed or existing air distribution system. to and the service area around the unit must have flooring. Ensure the temperature of the return air entering the furnace is between 55°F and 100°F when the To ensure proper furnace operation, install,operate and furnace is heating. maintain the furnace in accordance with these installa- Provide provisions for venting combustion products tion and operation instructions,all local building codes outdoors through a proper venting system. and ordinances. In their absence, follow the latest edition Special consideration should be given to vent/ of the National Fuel Gas Code(NFPA 54/ANSI Z223.1),and/ flue pipe routing and combustion air intake pipe or CAN/CSA B149.1-15 Installation Codes, local plumbing when applicable. Refer to Vent/Flue Pipe and or waste water codes, and other applicable codes. Combustion Air Pipe -Termination Locations for A copy of the National Fuel Gas Code (NFPA 54/ANSI appropriate termination locations and to determine Z223.1) can be obtained from any of the following: if the piping system from furnace to termination can be accomplished within the guidelines given. NOTE: American National Standards Institute The length of flue and/or combustion air piping can 25 West 43rd Street, 4th Floor be a limiting factor in the location of the furnace. New York, NY 10036 Locate the furnace so condensate flows downwards National Fire Protection Association to the drain. Do not locate the furnace or its 1 Batterymarch Park condensate drainage system in any area subject to Quincy, MA 02169-7471 below freezing temperatures without proper freeze protection. Refer to Condensate Drain Lines and CSA International Trap for further details. 8501 East Pleasant Valley Ensure adequate combustion air is available for Independence, OH 44131 the furnace. Improper or insufficient combustion air can expose building occupants to gas combustion products that could include carbon monoxide. Refer to Combustion and Ventilation Air Requirements. 6 • Set the furnace on a level floor to enable proper If the furnace is installed horizontally, ensure the condensate drainage. If the floor becomes wet or access doors are not on the "up/top" or "down/ damp at times, place the furnace above the floor on bottom" side of the furnace. a concrete base sized approximately 1-1/2" larger Do not connect this furnace to a chimney flue that than the base of the furnace. Refer to the Horizontal serves a separate appliance designed to burn solid Applications and Considerations for leveling of fuel. horizontal furnaces. On Counterflow Installations,the air conditioning coil • Ensure upflow or horizontal furnaces are not installed must be downstream on the supply (positive) side directly on carpeting, or any other combustible of the furnace heat exchanger. material. The only combustible material allowed is Counterflow Installation over noncombustible floor. wood. Before setting the furnace over the plenum opening, • Exposure to contaminated combustion air will result ensure the surface around the opening is smooth in safety and performance-related problems. Do and level.A tight seal should be made between the not install the furnace where the combustion air is furnace base and floor by using a silicone rubber exposed to the following substances: caulking compound or cement grout. permanent wave solutions Counterflow Installation over a combustible floor carbon tetrachloride If installation over a combustible floor becomes deicing salts or chemicals necessary, use an accessory subbase (see cleaning solutions (such as perch loroethylene) Specification Sheet applicable for your model for paint removers details.) A special accessory subbase must be cements and glues used for upright counterflow unit installations over any combustible material including wood. Refer chlorinated waxes or cleaners to subbase instructions for installation details. water softening chemicals Follow the instructions with the subbase for proper halogen type refrigerants installation. Do not install the furnace directly on chlorine-based swimming pool chemicals carpeting, tile, or other combustible material other printing inks than wood flooring. varnishes hydrochloric acid NOTE:The subbase will not be required if an air conditioning antistatic fabric softeners for clothes dryers coil is installed between the supply air opening on the furnace and the floor. • Seal off a non-direct vent furnace if it is installed CLEARANCES AND ACCESSIBILITY near an area frequently contaminated by any of NOTES: the above substances.This protects the non-direct For servicing or cleaning, a 24"front clearance is ventfurnace from airborne contaminants.To ensure required. that the enclosed non-direct vent furnace has an adequate supply of combustion air, vent from a Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum nearby uncontaminated room or from outdoors. Refer to the Combustion and Ventilation Air clearances listed above. Requirements for details. In all cases, accessibility clearance must take • If the furnace is used in connection with a cooling precedence over clearances from the enclosure coil unit, install the furnace upstream or in parallel where accessibility clearances are greater. with the cooling coil unit. Premature heat exchanger failure will result if the cooling unit is placed ahead NOTES: of the furnace. For servicing or cleaning, a 24" front clearance is For vertical (upflow or downflow) applications, the required. minimum cooling coil width shall not be less than Unit connections (electrical, flue and drain) may furnace width minus 1". Additionally,a coil installed necessitate greater clearances than the minimum above an upflow furnace or under a counterflow clearances listed above. furnace may be the same width as the furnace or In all cases, accessibility clearance must take may be one size larger than the furnace. Example: precedence over clearances from the enclosure a "C" width coil may be installed with a `B" width where accessibility clearances are greater. furnace. For upflow applications,the front of the coil and furnace must face the same direction. • If the furnace is installed in a residential garage, position the furnace so that the burners and ignition source are located not less than 18 inches(457 mm) above the floor. Protect the furnace from physical damage by vehicles. 7 Clearance in accordance with local installation codes,the requirements of the gas supplier and the manufacturer's A WARNING installation instructions. CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each Degaugement conforme aux codes d'installation locaux,aux appliance connected to the venting system being placed exigences du fournisseur de gaz et aux instructions into operation could result in carbon monoxide poisoning d'installation du fabricant. or death. The following steps shall be followed with each appliance Installations must adhere to the clearances t0 combustible connected to the venting system placed in operation, materials to which this furnace has been design certified. The while any other appliances connected to the venting minimum clearance information for this furnace is provided system are not in operation: on the unit's clearance label.These clearances must be per- manently maintained. Clearances must also accommodate 1. Seal any unused openings in theventing system. an installation's gas, electrical, and drain trap and drain line 2. Inspect the venting system for proper size and connections. If the alternate combustion air intake orvent/flue horizontal pitch,as required by the National Fuel Gas connections are used additional clearance must be provided Code,ANSI Z223.1 or the Natural Gas and Propane to accommodate these connections. Refer to Vent/Flue Pipe Installation Code, CSA B149.1-15 and these and Combustion Air Pipe for details. instructions. Determine that there is no blockage or NOTE: In addition to the required clearances to combustible restriction,leakage,corrosion and other deficiencies materials, a minimum of 24 inches service clearance must which could cause an unsafe condition. be available in front of the unit. 3. As far as practical, close all building doors and *M9C96 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS windows and all doors between the space in which (INCHES) the appliance(s)connected to the venting system are POSITION* SIDES REAR FRONT BOTTOM FLUE TOP located and other spaces of the building. Upflow 0" 0" 3" C 0" 1" Horizontal 6" o" 3" C o" 6" 4. Close fireplace dampers. C=If placed on combustible floor,floor MUST be wood only. 5. Turn on clothes dryers and any appliance not *C9C96 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS connected to the venting system. Turn on any (INCHES) exhaust fans, such as range hoods and bathroom POSITION* SIDES REAR FRONT BOTTOM FLUE TOP exhausts,so they shall operate at maximum speed. Counterflow 0" 0" 3" C 0" 1" Do notoperatea summer exhaust fan. Horizontal 6" 0" 3" C 0" 6" C=If placed on combustible floor,floor MUST be wood only. 6. Follow the lighting instructions. Place the appliance NC=For installation on non-combustible floors only.A combustible being inspected in operation. Adjust thermostat so subbase must be used for installations on combustible flooring. appliance shall operate continuously. 7. Test for spillage from draft hood appliances at the draft hood relief opening after 5 minutes of main TOP burner operation. Use the flame of a match or C TOP candle. O 8. If improper venting is observed during any of the SIDE SIDE SIDE 00 SIDE above tests,the venting system must be corrected in BOaccordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 and/or National Gas and Propane BOTTOM p Installation Code CSA 6149.1-15. BOTTOM 9. After it has been determined that each appliance Upflow Counterflow Horizontal connected to the venting system properly vents Figure 1 when tested as outlined above, return doors, Afurnace installed in a confined space(i.e.,a closet or utility windows, exhaust fans, fireplace dampers and any room) must have two ventilation openings with a total min- other gas burning appliance to their previous imum free area of 0.25 square inches per 1,000 BTU/hr of conditions of use. furnace input rating. Refer to Specification Sheet applicable to your model for minimum clearances to combustible surfaces. One of the ventilation openings must be within 12 inches of the top; the other opening must be within 12 inches of the bottom of the confined space. In a typical construction, the clearance between the door and door frame is usually ade- quate to satisfy this ventilation requirement. 8 EXISTING FURNACE REMOVAL AAVERTISSEMENT NOTE:When an existing furnace is removed from a venting RISQUE D'INTOXICATION AU MONOXYDE DE CARBONE system serving other appliances,the venting system may be Si les etapes decrites ci-clessous ne sont pas suivies pour too large to properly vent the remaining attached appliances. chacun des appareils raccordes au systeme de ventilation au moment de sa mise en marche,cela peut entrainer une The following vent testing procedure is reproduced from intoxication au monoxyde de carbone ou la mort. Les the American National Standard/National Standard etapes suivantes doivent etre suivies pour chacun des of Canada for Gas-Fired Central Furnaces ANSI Z21.47, appareils raccordes au systeme de ventilation au moment CSA-2.3 latest edition Section 1.23.1. de sa mise en marche,alors clue tous les autres appareils The following steps shall be followed with each appliance raccordes au systeme de ventilation ne sont pas en marche : connected to the venting system placed in operation, while 1)Sceller toutes les ouvertures inutilisees du systeme de any other appliances connected to the venting system are ventilation. not in operation: 2)Inspecter le systeme de ventilation afin de verifier si la 1. Seal any unused openings in the venting system. taille et I'inclinaison par rapport a Morizontale sont conformes aux exigences du National Fuel Gas Code,ANSI 2. Inspect the venting system for proper size and hor- Z223.1/NFPA 54 ou du Code d'installation du gaz nature) izontal pitch, as required by the National Fuel Gas et du propane,CSA B149.1 et a ces instructions.Verifier Code, ANSI Z223.1 or the Natural Gas and Propane qu'il n'y a pas d'obstruction ou de restriction,de fuite,de Installation Code, CSA B149.1-15 and these instruc- corrosion et d'autres problemes qui pourraient entrainer tions. Determine that there is no blockage or restriction, une situation clangereuse. leakage, corrosion and other deficiencies which could 3)Si possible,fermer toutes les portes et fenetres du cause an unsafe condition. batiment ainsi clue toutes les portes separant 1'endroit o6 se trouvent les appareils raccordes au systeme de 3. As far as practical,close all building doors and windows ventilation et les autres zones du batiment. and all doors between the space in which the appli- 4)Fermer le registre des foyers. ance(s) connected to the venting system are located 5)Mettre les secheuses en marche ainsi clue tous les and other spaces of the building. autres appareils qui ne sont pas raccordes au systeme de ventilation. Mettre en marche tous les ventilateurs de 4. Close fireplace dampers. tirage,comme celui des hottes de cuisine et des salles de 5. Turn on clothes dryers and any appliance not connect- bains,et les regler a la puissance maximale. Ne pas mettre ed to the venting system. Turn on any exhaust fans, en marche les ventilateurs cl'ete. such as range hoods and bathroom exhausts, so they 6)Suivre les instructions d'allumage. Mettre en marche shall operate at maximum speed. Do not operate a I'appareil soumis a l'inspection. Regler le thermostat de summer exhaust fan. maniere a ce clue I'appareil fonctionne en continu. 7)Verifier la presence de fuite au niveau de l'ouverture du 6. Follow the lighting instructions. Place the appliance coupe-tirage des appareils qui en sont dotes apres 5 being inspected In operation. Adjust thermostat so minutes de fonctionnement du bruleur principal. Utiliser appliance shall operate continuously. la flamme d'une allumette ou d'une bougie. 8)Si un probleme de ventilation est observe pendant l'un 7. Test for spillage from draft hood appliances at the draft des essais decrits ci-dessus,des correctifs doivent etre hood relief opening after 5 minutes of main burner apportes au systeme de ventilation conformement au operation. Use the flame of a match or candle. National Fuel Gas Code,ANSI Z223.1/NFPA 54 et(ou)au 8. If improper venting is observed during any of the above Code d'installation du gaz nature)et du propane,CSA 6149.1. tests, the venting system must be corrected in accor- 9)Une fois qu'il a ete determine clue chaque appareil dance with the National Fuel Gas Code ANSI Z223.1/ raccorde au systeme de ventilation fonctionne NFPA54 and/or National Gas and Propane Installation correctement au moyen des essais decrits ci-dessus, les Code CSA 13149.1-15. portes,les fenetres, les ventilateurs, les registres de foyer 9. After it has been determined that each appliance et tous les autres appareils de combustion alimentes au connected to the venting system properly vents when gaz doivent etre remis clans Ieur etat initial. tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous conditions of use. If resizing is required on any portion of the venting system, use the appropriate table in Appendix G in the latest edi- tion of the National Fuel Gas Code ANSI Z223.1 and/or CSA 13149.1-15 Installation Codes. 9 THERMOSTAT LOCATION INSTALLATION POSITIONS AIR The thermostat should be placed approximately five feet from DISCHARGE the floor on a vibration-free, inside wall in an area having good air circulation. Do not install the thermostat where it H may be influenced by any of the following: • Drafts, or dead spots behind doors, in corners, or under cabinets. Side :Retuide• Hot or cold air from registers. ReturnrnDuctuct• Radiant heat from the sun. connectionnectio • Light fixtures or other appliances. LBOttom • Radiant heat from a fireplace. eturn Duct• Concealed hot or cold water pipes, or chimneys. nnectio • Unconditioned areas behind the thermostat, such as an outside wall. UPFLOW UPRIGHT Consult the instructions packaged with the thermostat Figure 2A for mounting instructions and further precautions. Bottom a 00 Return COMBUSTION & VENTILATION AIR Duct DISCHARGE Connection REQUIREMENTS WARNING UPFLOW HORIZONTAL LEFT AIR DISCHARGE TO AVOID PROPERTY DAMAGE,PERSONAL INJURY OR DEATH, Figure 2B SUFFICIENT FRESH AIR FOR PROPER COMBUSTION AND VENTILATION OF FLUE GASES MUST BE SUPPLIED. MOST HOMES REQUIRE OUTSIDE AIR BE SUPPLIED INTO THE FURNACE AREA. LBottom 00Improved construction and additional insulation in buildings AIR have reduced heat loss by reducing air infiltration and escape n DISCHARGE around doors and windows. These changes have helped in UPFLOW HORIZONTAL reducing heating/cooling costs but have created a problem RIGHT AIR DISCHARGE supplying combustion and ventilation air for gas fired and other fuel burning appliances. Appliances that pull air out Figure 2C of the house (clothes dryers, exhaust fans, fireplaces, etc.) increase the problem by starving appliances for air. nRrHouse depressurization can cause back drafting or improper combustion of gas-fired appliances,thereby exposing build- ing occupants to gas combustion products that could include carbon monoxide. If this furnace is to be installed in the same space with other gas appliances, such as a water heater, ensure there is an adequate supply of combustion and ventilation air for the p other appliances. Refer to the latest edition of the National c Fuel Gas Code NFPA54/ANSI Z223.1 or CAN/CSAB149.1- 15 Installation Codes or applicable provisions of the local AIR DISCHARGE building codes for determining the combustion air require- ments for the appliances. Most homes will require outside air be supplied to the fur- Figure 2D nace area by means of ventilation grilles or ducts connecting directly to the outdoors or spaces open to the outdoors such as attics or crawl spaces. 10 Recommended Installation Positions 3. Locate 24"x 1/4"tube in bag assembly. 4. Install one end on front cover pressure switch. *M9C96 models may be installed upflow or horizontally with 5. Route tube to lower port on collector box cover and cut left or right side down. *C9C96 models may be installed down off excess tubing. flow or horizontally with left or right side down. Do not install this furnace on its back. For upright upflow furnaces, return air DRAIN TRAP AND LINES ductwork may be attached to the side panel(s)and/or base- pan. For horizontal upflow furnaces, return air ductwork must In horizontal applications the condensate drain trap is secured be attached to the basepan. For both upright or horizontal to the furnace side panel, suspending it below the furnace. A counterflow furnaces, return ductwork must be attached to minimum clearance of 5.5"below the furnace must be provid- the basepan (top end of the blower compartment). NOTE: ed for the drain trap. Additionally,the appropriate downward Ductwork must never be attached to the back of the furnace. piping slope must be maintained from the drain trap to the Refer to "Recommended Installation Positions" figure for drain location. Refer to Condensate Drain Trap and Lines for appropriate installation positions,ductwork connections,and further details. If the drain trap and drain line will be exposed resulting airflow arrangements. to temperatures near or below freezing, adequate measures must be taken to prevent condensate from freezing. HORIZONTAL APPLICATIONS HORIZONTAL FURNACE LEVELING & CONSIDERATIONS Leveling ensures proper condensate drainage from the heat exchanger. For proper flue pipe drainage, the furnace must When installing a furnace horizontally, additional consider- be level lengthwise from end to end. The furnace should have ation must be given to the following: a slight tilt from back to front with the access doors downhill from the back panel approximately 1/2 to 3/4 inches. The FURNACE SUSPENSION slight tilt allows the heat exchanger condensate, generated If suspending the furnace from rafters or joists, use 3/8" in the recuperator coil,to flow forward to the recuperator coil threaded rod and 2"xZxl/8" angle iron as shown in the front cover. following diagram. The length of rod will depend on the ALTERNATE ELECTRICAL AND GAS LINE CON- application and the clearances necessary. NECTIONS If the furnace is installed in a crawl space it must be sus- This furnace has provisions allowing for electrical and gas pended from the floor joist or supported by a concrete pad. line connections through either side panel. In horizontal Never install the furnace on the ground or allow it to be applications the connections can be made either through the exposed to water. PROVIDE$"MIN "top" or"bottom" of the furnace. MINIMUM CLEARANCE BETWEEN CENTER ROD AND FURNACE CABINET DRAIN PAN TO ALLOW FOR CIRCULATOR BLOWER REMOVAL 3/$"DIAMETER A drain pan must be provided if the furnace is installed above THREADED ROD ASSURE FURNACE IS LEVEL FROM ($PLACES) END TO END AND HAS A SLIGHT FORWARD TILT WITH THE FRONT a conditioned area. The drain pan must cover the entire area OF THE FURNACE 0"-3/4" BELOW THE BACK OF THE FURNACE under the furnace (and air conditioning coil if applicable). HOLD DOWN NUTS G FREEZE PROTECTION SUPPORT NUTS Refer to Horizontal Applications and Conditions-Drain Trap and Lines. 2"�"x3/$°ANGLE IRON PROPANE GAS/HIGH ALTITUDE (3 PLACES) ZTILT OUTWARD TO ALLOW FOR POSITION AS CLOSE AS POSSIBLE TO BLOWER DECK TO ALLOW FOR DOOR AND CIRCULATOR BLOWER INSTALLATIONS CIRCULATOR BLOWER REMOVAL REMOVAL Figure 3 AWARNING FRONT COVER PRESSURE SWITCH TUBE POSSIBLE PROPERTY DAMAGE,PERSONAL INJURY OR DEATH MAY OCCUR IF THE CORRECT CONVERSION KITS ARE NOT INSTALLED.THE LOCATION APPROPRIATE KITS MUST BE APPLIED TO ENSURE SAFE AND PROPER FURNACE OPERATION.ALL CONVERSIONS MUST BE PERFORMED BY A When a furnace is installed horizontally with left side down, QUALIFIED INSTALLER OR SERVICE AGENCY. the front cover pressure switch tube must be re-located to he lower port of the collector box cover. 1. Remove tube from front cover pressure switch and This furnace is shipped from the factory configured for natural collector box cover. gas at standard altitude. Propane gas installations require 2. Remove rubber plug from bottom collector box port and an orifice and spring change to compensate for the energy install on top of collector box port. content difference between natural and propane gas. 11 High altitude installations may require both a pressure switch This furnace is dual certified and may be installed as a non- and an orifice/spring change. These changes are necessary direct vent(single pipe)or direct vent(dual pipe)appliance. to compensate for the natural reduction in the density of both the gas fuel and the combustion air at higher altitude. MATERIALS - INSTALLATIONS IN THE U.S.A For furnaces being converted to LP gas, it is strongly rec- ommended that a LPLP03 kit also be installed. The use of PVC, CPVC, or ABS pipe & fittings are typically used as this kit will prevent the furnace from firing when the LP gas venting and intake pipe materials. All 90' elbows must be supply pressure is too low to support proper combustion. medium or long radius types.A medium radius elbow should measure —3-1/16" minimum from the plane of one opening Installation of this furnace at altitudes above 7000 ft(2134 m) to the center line of the other opening for 2" diameter pipe, shall be made in accordance with the Listed High Altitude and —4-9/16" minimum for 3" pipe. Conversion Kit available with this furnace" In addition to these materials, Innoflue® by Centrotherm Eco Systems and PolyPro® by M&G Duravent are also L'installation de ce generateur de chaleur a des altitudes approved vent and combustion air materials for installations superieures a 7000 pi (2134 m)doit titre effectuee in the U.S.A. Manufacturers Installation instructions for these conformement aux instructions accompagnant la trousse de products must be followed. These products have specific conversion pour haute altitude fournie avec cet appareil. instructions for installing,joining and terminating. Do not mix materials or components of one manufacturer with materials or components of another manufacturer.Refer to the following For installations above 7000 feet, please refer to the furnace chart for plastic pipe &fittings specifications Specification Sheets for required kit(s). Contact the distributor for a tabular listing of appropriate MATERIALS - INSTALLATIONS IN CANADA manufacturer's kits for propane gas and/or high altitude installations. The indicated kits must be used to insure safe All installations in Canada must conform to the requirements and proper furnace operation. All conversions must be per- of CAN/CSA B149.1-15 code.All vent components, including formed by a qualified installer, or service agency. primer and cement, must be listed to ULC S636.The certified pipe and fittings should be clearly marked with the ULC GAS ALTITUDE KIT ORIFICE MANIFOLD PRESSURE PRESSURE standard "S636". The primer and cement used must be of HIGHSTAGE LOWSTAGE SWITCH the same manufacturer as the vent system. For Royal Pipe NATURAL NONE #5045(1) 3.5"w.c. 1.9"w.c. NONE System 636; use GVS-65 Primer(Purple)and GVS-65 PVC 0-7000 #so(z) Y ( p ) PROPANE LPM-08*(1) 1.25MM(1) 10.0"w.c. 6.0"w.c. NONE Solvent Cement. For IPEX System 636, use PVC/CPVC LPM-30*(2) #57(2) Primer, Purple or clear. Use PVC Solvent cement(Gray). For *supports both Honeywell and White-Rodgers 2-stage valves Canadian installations,ABS may be used as a combustion air (1)FOR USE WITH ALL MODELS EXCEPT*M9C960303AN (2)FOR USE WITH ONLY*M9C960303AN pipe only.ABS is not an approved vent material in Canada. If ABS is used as a combustion air pipe, it must be CSA VENT PIPE & COMBUSTION AIR certified.Always follow the manufacturer's instructions in the use of primer and cement. Do not use primer and cement around potential sources of ignition. Do not use primer or A WARNING cement beyond its expiration date. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN BODILY MATERIALS AND JOINING METHODS INJURY OR DEATH.CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS GIVEN IN THIS SECTION. AWARNING AWARNING TO AVOID BODILY INJURY,FIRE OR EXPLOSION,SOLVENT CEMENTS UPON COMPLETION OF THE FURNACE INSTALLATION,CAREFULLY MUST BE KEPT AWAY FROM ALL IGNITION SOURCES(I.E.,SPARKS,OPEN INSPECT THE ENTIRE FLUE SYSTEM BOTH INSIDE AND OUTSIDE OF THE FLAMES,AND EXCESSIVE HEAT)AS THEY ARE COMBUSTIBLE LIQUIDS. FURNACE TO ASSURE IT IS PROPERLY SEALED. LEAKS IN THE FLUE AVOID BREATHING CEMENT VAPORS OR CONTACT WITH SKIN AND/OR SYSTEM CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH DUE TO EYES. EXPOSURE TO FLUE PRODUCTS, INCLUDING CARBON MONOXIDE. This manual will refer to the pipe that discharges products of combustion to the outdoors as the"vent" pipe or"flue" pipe. The pipe that supplies air for combustion to the furnace will be referred to as the "intake" pipe or"combustion air" pipe. 12 VENTING MATERIAL REQUIREMENTS PVC ASTM STANDARD WARNING SCHEDULE 40 PIPE D1785 TO AVOID BODILY INJURY, FIRE OR EXPLOSION, SOLVENT SCHEDULE 40 CELLULAR CORE PIPE F891 CEMENTS MUST BE KEPT AWAY FROM ALL IGNITION SDR 21 OR 26 PIPE D2241 SOURCES (I.E., SPARKS, OPEN FLAMES, AND EXCESSIVE FITTINGS D2466 HEAT)AS THEY ARE COMBUSTIBLE LIQUIDS.AVOID ABS BREATHING CEMENT VAPORS OR CONTACT WITH SKIN SCHEDULE 40 PIPE D1527 AND/OR EYES. SCHEDULE 40 CELLULAR CORE PIPE F628 FITTINGS D2468 CPVC PREFERRED SCHEDULE 40 PIPE F441 TRANSITION MADE IN VERTICAL SECTION OF PIPE SDR 21 OR 26 PIPE F442 FITTINGS F438 POLYPROPYLENE INNOFLUEO(CENTROTHERM) POLYPROO(DURAVENT) PRIMER&SOLVENT CEMENT PVC PRIMER F656 CPVC PRIMER F656 PVC SOLVENT CEMENT D2564 CPVC SOLVENT CEMENT F493 ABS SOLVENT CEMENT D2235 ABS/PVC/CPVC ALL PURPOSE CEMENT(FOR PIPE& D2564,D2235,F493 Figure 4 FITTINGS OF THE SAME MATERIAL) TRANSITION CEMENT FOR ABS TO PVC or CPVC D3188 INSTALLATIONS IN CANADA ACCEPTABLE PVC&CPVC PIPE&FITTINGS PVC&CPVC SOLVENT CEMENT TRANSITION CEMENT ULC S636 INNOFLUEO(CENTROTHERM) POLYPROO(DURAVENT) TRANSITION NO LESS WARNING THAN 45 DEGREES TO HORIZONTAL PLANE TO UPON COMPLETION OF THE FURNACE INSTALLATION, AVOID CREATING A WATER TRAP IN VENT PIPING. CAREFULLY INSPECT THE ENTIRE FLUE SYSTEM BOTH INSIDE AND OUTSIDE OF THE FURNACE TO ASSURE IT IS PROPERLY SEALED. LEAKS IN THE FLUE SYSTEM CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH DUE TO EXPOSURE TO FLUE PRODUCTS, INCLUDING CARBON Figure 5 MONOXIDE. WARNING NO TRANSITION ON HORIZONTAL PLANE, THIS CREATES FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT WATER TRAP AND IN BODILY INJURY OR DEATH. CAREFULLY READ AND RESTRICTS FLUE GASES FOLLOW ALL INSTRUCTIONS GIVEN IN THIS SECTION. Figure 6 13 TERMINATION LOCATIONS Non-Direct Vent Direct Vent Vent/Flue Terminations Non-Direct Vent V Vent/Flue Termination E N No Terminations T Above Walkway m O 45 DEGREE <10' 4 min. LONG-SWEEP 12' � 4 3'min. 4• ELBOWS ° 12"2" y \ min. Grade or Highest "-O\12"min. Anticipated i Snow Level 12'min. i Non-Direct Vent Forced Air Vent/Flue Termination Inlet Figure 9 Direct Vent Vent/Flue Termination Insert flange. Cut 2 1/2" long. SEE FIGURE 8 Vent Clearances M_ �.2/z Figure 7 VENT-DRAIN • ° • •e e� o 0 0 CLAMPS TO BE •• PLACEDINTO 0 GROOVES 0 ON DRAIN r ' AS SHOWN. s 0 0 • •s CAP TO BE INSTALLED ° ON LIN-USED DRAIN PORT RF000142 Coupling Figure 8 WARNING Figure 10 EDGES OF SHEET METAL HOLES MAY BE SHARP. USE GLOVES AS A PRECAUTION WHEN REMOVING HOLE PLUGS. 14 *MEC96/*CEC96 Direct Vent (2 - Pipe) and Non-Direct Vent (1- Pipe) (6) Maximum Allowable Length of Vent/Flue Pipe MODEL Pipe Size Number of Elbows(3)(5) (4) (in.) 1 2 3 4 5 6 7 8 *M 9C960303AN 2 75 70 65 60 55 50 45 40 Et *M 9C960403AN 3 114 107 100 93 86 79 72 65 *M 9C960603AN 2 75 70 65 60 55 50 45 40 3 114 107 100 93 86 79 72 65 2 50 45 40 35 30 25 20 15 *M 9C960603BN^ 3 143 136 129 122 115 108 101 94 *M 9C960803BN 2 60 55 50 45 40 35 30 25 3 113 106 99 92 85 78 71 64 *M 9C960804CN 2 60 55 50 45 40 35 30 25 3 120 113 106 99 92 85 78 71 2 45 40 35 30 25 20 15 10 *M 9C961004CN 3 103 96 89 82 75 68 61 54 2 45 40 35 30 25 20 15 10 *M 9C961005CN 3 151 144 137 130 123 116 109 102 *M 9C961205DN 3 185 178 171 164 157 150 143 136 *C9C960403BN 2 100 95 90 85 80 75 70 65 3 110 103 96 89 82 75 68 61 *C9C960603BN 2 45 40 35 30 25 20 15 10 3 110 103 96 89 82 75 68 61 *C9C960803BN 2 35 30 25 20 15 10 5 NA 3 103 96 89 82 75 68 61 54 2 45 40 35 30 25 20 15 10 *C9C961005CN 3 110 103 96 89 82 75 68 61 *M9C960603BN-add 45' of 2" pipe for upflow. FLANGE WARNING - - - - I THE RUBBER ELBOW IS NOT DESIGNED TO SUPPORT UI A LOAD. WHEN THE RUBBER ELBOW IS MOUNTED =I EXTERNALLY TO THE FURNACE CABINET, EXTREME CARE MUST BE TAKEN TO ADEQUATELY SUPPORT FIELD- SUPPLIED VENT/FLUE PIPING, AS DAMAGE CAN RESULT 1 IN LEAKS CAUSING BODILY INJURY OR DEATH DUE 6 I TO EXPOSURE TO FLUE GASES, INCLUDING CARBON MONOXIDE. Figure 11 15 COMBUSTION AIR INTAKE OPTIONS (SEE FIGURE 12) VENT/FLUE PIPE TERMINATIONS The RF000142 coupling (Figure 8) can be secured directly 112" to the furnace intake coupling if condensation is a concern. If the RF000142 is used on the combustion air inlet, it must be installed with the arrow pointing up. It should be noted, VENTIFLUE TEE(OPTIONAL) or the combustion air will actually be moving in a direction 45°ELBOW TURNED DOWN or opposite of the arrow on the RF000142 coupling. It must so°ELBOW TURNED DOWN have a field supplied, trapped drain tube free-draining to proper condensate disposal location. A loop in the drain tube can serve as a trap.The unused RF000142 drain fitting12"MIN.ABOVE HIGHEST ANTICIPATED should be capped.Atee installed in the intake pipe is also anSNOW LEVEL acceptable method of catching condensation. It must have a field supplied, trapped drain tube or pipe, free-draining to proper condensate disposal location.A loop in the drain tube can serve as a trap. Horizontal Termination (Single Pipe) Above Highest Anticipated Snow Level Exhaust Figure 13 Combustion Ail I 5-12" A COM(OP VENT/FLUE PIPE (TEE OPTIONAL) 0°OR 45° E / 12"MIN.TO GRADE OR HIGHEST ANTICIPATED 1_.I• SNOW LEVEL Standard"Horizontal Terminations (Dual Pipe) Figure 14 mot— DOWN VENTING UPFLOW MODEL FURNACES ONLY COMBUSTION AIR INTAKE OPTIONS 0 Figure 12 use alternate vent ® &combination ACAUTION air locations I � BE SURE NOT TO DAMAGE INTERNAL WIRING OR OTHER o Vent Pipe 6'Max. o COMPONENTS WHEN REINSTALLING COUPLING AND SCREWS. Floor Combustion Air Pipe Field Supplied NOTE: FOR INSTALLATIONS AT OR ABOVE 7,000 FEET Drain Tee on Vent Pipe Both Pipes Terminated Outside Structure ALTITUDE, USE 3" VENTING. 1/4"per foot min. Cta`HtSpare slope to furnace 535e�e�t I to prevent flue gas from escaping and routed to field supplied condensate disposal All piping and fittings must be joined per material manufacturers specifications to prevent separation and flue gas leaks. Figure 15 16 TEE(OPTIONAL) 0-00 VENT/FLUE COMBUSTION AIR INTAKE ��12"MIN TEE (OPTIONAL) HEIGHT DIFFERENCE *Not required for BETWEEN single pipe installation INTAIKE AND VENT INTAKE \ � FACING FA CING ��0t L\N� DOWN \\ COMBUSTION DISTANCE AND BETWGRADEEN AIR INTAKE. DISTANCE BETWEEN \C\' COMBUSTION AIR INTAKE AND GRADE a 12"MIN TO ROOF HIGHEST ANTICIPATED SNOW LEVEL Figure 16 Figure 19 VENT PIPE TERMINATION OPTIONS VENT ELBOWS i2.MIN PND✓ENT NrPNE TEE / 3"-24' EEN PIPEQ ELBOWS / _ /✓�''"� / p�.� 1�ABOVE S T RA I G H HIGHEST ANTICIPATED .� `� SNOW LEVEL Combustion Air Intake may also be snorkeled to obtain 12"min ground clearance. Alternate vent termination above anticipated snow level (dual pipe) Figure 20 Direct Vent(Dual Pipe) Piping Figure 17 VENT/FLUE AND COMBUSTION AIR PIPE 90° ---VENT TERMINATIONS ELBOW HWS IN BENT I ?Ar 3"MIN 24"MAX I / 12"MIN SEPARATION / / Y 3"MIN__ 12" MIN.ABOVE HIGHEST ANTICIPATED SNOW LEVEL X 12"IN TO GRADE OR HIGHEST Alternate Horizontal Vent Termination (Dual Pipe) )-*-,*-ANTICIPATED SNOW LEVEL Figure 18 "� Termination of Multiple Direct Vent Furnaces Figure 21 17 VENT/INTAKE TERMINATIONS FOR INSTALLATION OF MULTIPLE DIRECT VENT FURNACES fD If more than one direct vent furnace is to be installed vertically Horizontal Installation o through a common roof top, maintain the same minimum o clearances between the exhaust vent and air intake termi- nations of adjacent units as with the exhaust vent and air o intake terminations of a single unit. 0 Cl Vertical Installation If more than one direct vent furnace is to be installed horizon- Side Wall Vent Kit tally through a common side wall, maintain the clearances Figure 23 as in the following figure. Always terminate all exhaust vent CONDENSATE DRAIN LINES & DRAIN outlets at the same elevation and always terminate all air intakes at the same elevation. TRAP / A condensing gas furnace achieves its high level of efficien- cy by extracting heat from the products of combustion to / the point where condensation takes place. The condensate YMIN must be collected in the furnace drain trap and routed to z4"MAx / an appropriate drain location in compliance with local and / national codes. 12"MIN SEPARATION Follow the bullets listed below when installing the drain / 3°MI system. Refer to the following sections for specific details concerning furnace drain trap installation and drain hose hook ups. The drain trap supplied with the furnace must be used. M� The drain trap must be primed at time of �12"MIN TO GRADE OR HIGHEST installation. J-4-0 ANTICIPATED SNOW LEVEL The drain line between furnace and drain location must meet local and national codes. Termination of Multiple Direct Vent Furnaces The drain line between furnace and drain location Figure 22 must maintain a 1/4 inch per foot downward slope toward the drain. CONCENTRIC VENT TERMINATION Do not trap the drain line in any other location than at the drain trap supplied with the furnace. Refer to the directions provided with the Concentric Vent Kit If the drain line is routed through an area which for installation specifications. may see temperatures near or below freezing, SIDE WALL VENT KIT precautions must be taken to prevent condensate from freezing within the drain line. This kit is to be used with 2" or 3" direct vent systems. The If an air conditioning coil is installed with the vent kit must terminate outside the structure and may be in- furnace, a common drain may be used. An open stalled with the intake and exhaust pipes located side-by-side tee must be installed in the drain line, to relieve or with one pipe above the other.These kits are NOT intended positive air pressure from the coil's plenum. This for use with single pipe (non-direct vent) installations. is necessary to prohibit any interference with the Refer to the directions furnished with the Side Wall Vent function of the furnace's drain trap. Kit (p/n 0170K00000S or 0170K00001S) for installation GENERAL DRAIN INFORMATION specifications. All furnace models come with a factory installed drain trap. For vertical installations, the trap will remain in the factory position. All furnace models installed horizontally require the trap to be relocated. Many drain hoses have a built—in grommet which will provide a cabinet seal when installed.See instructions below for your model and installation position. NOTE:Both sides of the drain trap must be primed prior to initial furnace start up. 18 FIELD SUPPLIED DRAIN AWARNING Drain the furnace and air conditioning coil if applicable, In EDGES OF SHEET METAL HOLES MAY BE SHARP. USE GLOVES AS A compliance with code requirements. In horizontal installa- tions,a field installed rubber coupling will allow the drain trap PRECAUTION WHEN REMOVING HOLE PLUGS. to be removed for cleaning. The drain trap must be primed before initial furnace start up. When an air conditioning coil A WARNING drain is connected to the field supplied furnace drain, it must HIGH VOLTAGE ! be vented with an open tee installed at a height no higher TO AVOID THE RISK OF INJURY,ELECTRICAL SHOCK OR than the bottom of the furnace collector box to prevent air DEATH,THE FURNACE MUST BE ELECTRICALLY conditioning condensate from backing up into the furnace if GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN the common drain became blocked. THEIR ABSENCE,WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE. ti A WARNING TO AVOID THE RISK OF INJURY,ELECTRICAL SHOCK OR DEATH,THE FURNACE MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH #1 #2 LOCAL CODES OR,IN THEIR ABSENCE,WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. #3 UPFLOW MODEL INSTALLED VERTICALLY The trap and factory installed hoses remain as shipped. #5 The furnace drain may exit either the right or left side of the #4 furnace cabinet. Both sides of the cabinet have two .875" diameter holes which can be used interchangeably for drain and low voltage wiring purposes. If a higher drain exit is need- ed, a .875" diameter hole may be added in the area shown in Figure 25. Any unused cabinet opening must be sealed. #7 #8 Do not allow drain hose to sag or trap water. #9 #10 Coupling Acceptable y, area for drain hole. 100 Degree _ #6 #11 Elbow Side Cut-Out 12" pl Figure 24 LJ Right side shown. NOTE:Hoses are model specific 3 Left side acceptable also. and not all hoses will be shipped with all models. Figure 25 DRAIN EXITING RIGHT SIDE 1. Locate and Install the 450 pipe / hose drain coupling from the outside of the cabinet(barbed end goes in the cabinet) through hole in the right side of the cabinet and secure with two field supplied #8 self-tapping screws (see Figure 26). 2. Locate the long drain hose#3 and cut at line "A". 3. Install large end of hose #3 to trap outlet and secure with 1.25" clamp. 19 4. Install smaller end of hose#3 on 451 elbow and secure 5. (Draining the Vent Elbow) Locate hose #2 (factory with 1" clamp. installed) and cut 1" away from the 45 degree bend, 5. Refer to Field Supplied Drain section for instructions discard the 45 degree section. Insert hose #2 from on field supplied / installed drain on outlet of furnace outside the cabinet through the cabinet drain hole trap. nearest the top. Secure it to the barbed fitting in the elbow with a red clamp. • 6. For models DM96VE0303AN, DM96VE0403AN and • ® e ®® DM96VE0603AN;locate the hose#2(factory installed) o and cut 1.5" length from the end of the hose. Insert hose#2 from outside the cabinet through the cabinet drain's hole nearest to the top. Secure it to the barbed fitting in the elbow with a red clamp. ® ose#1 7. (Draining the Collector Box) Install the non-grommet Hose#2 end of hose#11 from outside the cabinet in the bottom = drain hole. Install on collector box and secure with a silver clamp. 8. Use two silver clamps and secure the hoses to drain o trap. The trap outlet faces the front of the furnace. Q Secure the trap to the cabinet using two screws ❑• removed in step 2 by inserting the two screws through 45 degree 0 45 degree the large set of holes in the top mounting tabs of the barb-piped __ barb-pipe trap into the two predrilled holes in the side of the adapter adapter cabinet. 9. Refer to Field Supplied Drain section for instructions on field supplied/installed drain on outlet of furnace trap. Installer selects right or left side drain La and installs this hose accordingly. Figure 26 Blab DRAIN EXITING LEFT SIDE ® o 1. Install the 45 degree pipe/ hose drain coupling from �F_, 3 the outside of the cabinet (barbed end goes in the o o cabinet)through the hole in the left side of the cabinet ®� and secure with two field supplied #8 self-tapping screws (see Figure 26). 2. Locate the long drain hose#3 and cut at"B" line fora Hose#11 "7p Hose#2 17.5" cabinet; cut at line "C"for a 21" cabinet; do not cut for a "D"width cabinet. 3. Install large end of hose#3 to trap outlet and secure Figure 27 with 1.25" clamp. 4. Install smaller end of hose#3 on 451 elbow and secure UPFLOW MODEL INSTALLED HORIZONTALLY WITH with 1" clamp. LEFT SIDE DOWN (SEE FIGURE 28) 5. Refer to Field Supplied Drain section for instructions Minimum 5'/2"clearance is required for the drain trap on field supplied / installed drain on outlet of furnace beneath the furnace. trap. *Also see Front Cover Pressure Switch Tube Location on UPFLOW MODEL INSTALLED HORIZONTALLY WITH page 11 RIGHT SIDE DOWN (SEE FIGURE 27) 1. Remove the clamps from the two drain tubes on the trap. Minimum 5'/2"clearance is required for the drain trap 2. Remove the two screws holding the drain trap to the beneath the furnace. blower deck. 1. Remove the clamps from both ends of the drain hoses. 3. Remove the trap and hoses from the blower deck . 2. Remove the two screws holding the drain trap to the 4. Remove the two plugs from the left side of the cabinet blower deck. and install them in the blower deck. 3. Remove the trap and two hoses from the blower deck 5. (Draining the Vent Elbow) Locate hose#6. Measuring 4. Remove the two plugs from the right side of the cabinet from the non-grommet end; cut off and discard 1 '/2" and install them in the blower deck. for a"D"width cabinet, 5"for a"C"width cabinet, 8'/2" for a "B"width cabinet. 20 6. Remove the rubber plug from vent—drain elbow side 2. Install 90°radius end of hose #2 on RF000142 drain port. Place hose#6 on the vent—drain elbow side port outlet and secure with a red clamp. and secure with a silver clamp . 3. Insert coupling in hose#2 and secure with a red clamp. 7. Unused vent-drain elbow drip leg port must be 4. Locate hose#5 and cut 3"from the non-grommet end. sealed to prevent flue gases from escaping.Insert Discard the section without the grommet. the rubber plug removed in Step 6 into the unused 5. Insert the cut end of tube#5 through the lower cabinet elbow drain port; Inserting a blunt tool such as a drain hole. 3/16" Allen wrench into the center of the rubber 6. Insert 100 degree elbow in the cut end of hose#5. plug will stretch the plug and allow complete 7. Locate hose #6. Using red clamps, connect between insertion. the coupling and 100 degree elbow,cutting off excess 8. Locate hose#5 and cut 3"from the non-grommet end. tubing. Discard the section without the grommet. 8. (Draining the Collector Box) Remove cap from left 9. Insert the cut end of tube#5 through the lower cabinet side collector box drain port (bottom in horizontal left drain hole. position)and install it on right side (top)collector box 10. Connect hose #6 & hose #5 using 1001 elbow and drain port. secure with two red clamps. 9. Install the non-grommet end of hose#11 from outside the cabinet in the upper drain hole. Install on collector 11. (Draining the Collector Box) Remove cap from left box and secure with a silver clamp. side collector box drain port (bottom in horizontal left 10. Use two silver clamps and secure the hoses to drain position) and install it on the right side (top) collector trap. The trap outlet faces the front of the furnace. box drain port. Secure the trap to the cabinet using two screws 12. Install the non-grommet end of hose#11 from outside removed in step 2 by inserting the two screws through the cabinet in the upper drain hole. Install on collector the large set of holes in the top mounting tabs of the box and secure with a silver clamp. trap into the two predrilled holes in the side of the cabinet. 13. Use two silver clamps and secure the hoses to drain trap. The trap outlet faces the front of the furnace. insert flange. Cut 2 q/2"long. Secure the trap to the cabinet using two screws RF000142 f z removed in step 2 by inserting the two screws through the large set of holes in the top mounting tabs of the L ON _ trap into the two predrilled holes in the side of the cabinet. I o ° Q 14. Refer to Field Supplied Drain section for instructions on - d field supplied/installed drain on outlet of furnace trap. O a o 0 ® Ej Figure 29 COUNTERFLOW MODEL INSTALLED VERTICALLY Ll The furnace drain may exit the right or left side of the furnace cabinet(left side preferred)Trap and factory installed hoses • remain as shipped if the drain will exit the left side of the Hose#6 Ho #5 Hose#11 cabinet. Draining from the right side requires relocation of the trap to outside the cabinet. Figure 28 DRAIN EXITING LEFT SIDE (SEE FIGURE 30) UPFLOW MODEL INSTALLED HORIZONTALLY WITH 1. Install a field supplied rubber coupling secured with LEFT SIDE DOWN-ALTERNATE (SEE FIGURE 29) a 1 1/4" clamp to enable removing the trap for future *Also see Front Cover Pressure Switch Tube Location on cleaning. Alternately, a PVC fitting may be glued on page 11 the trap outlet. 1. (Draining the RF000142 Coupling) Locate hose #2 2. Install drain per local and National codes. (factory installed).Cut off and discard the 45°radius end. 21 COUNTERFLOW MODEL INSTALLED HORIZONTAL- LY WITH RIGHT SIDE DOWN (SEE FIGURE 32) Minimum 5 112"clearance is required for the drain trap be- neath the furnace. n ° NOTE: For horizontal installations, some of the required hoses are found in the factory-installed hose assemblies. Remove the hose clamps to obtain the respective hoses needed for installation,and install per the following directions. FrEff 0 o e 1. Remove the drain trap and factory installed drain tube • assemblies. 2. Remove two 1" plugs from right side of cabinet. 3. (Draining the Collector Box) From outside the cabinet, insert the non-grommet end hose#7 into the back drain hole and secure to collector box drain port using a silver clamp. 4. (Draining the Vent Elbow) Insert the straight barbed coupling into the vent- drain elbow drip leg and secure Hose #4 x 3 Hose #5 with a red clamp. 5. From outside the cabinet, insert the non-grommet end Figure 30 of hose #8 into the front cabinet drain hole and secure on the vent-drain elbow barb fitting using a red clamp. DRAIN EXITING RIGHT SIDE (SEE FIGURE 31) 6. Place the drain hoses on the trap inlets and secure with 1. Remove hose clamps and hoses from trap. silver clamps.The outlet of the trap must face the original bottom of furnace. 2. Remove trap and factory installed drain tube assemblies. 7. Using the two sheet metal screws provided in the cabinet, 3. (Draining the Vent Elbow) Insert the non-grommet end secure the trap to the furnace. hose #10 into the cabinet back drain hole. Insert a 8. Refer to Field Supplied Drain section for instructions on coupling into the drip leg of the vent-drain elbow and field supplied/installed drain on outlet of furnace trap. secure with a silver clamp. Secure hose #10 on vent - drain elbow barb fitting with a silver clamp. 4. (Draining the Collector Box) Insert non-grommet end of hose#9 into the cabinet front drain hole and secure on ' collector box drain port with a silver clamp. a 5. Mate the drain trap inlets to the hoses and secure with • silver clamps. 6. Line up the trap mounting holes with the pre-drilled holes in the furnace and secure with 2 screws removed in step 2. 7. Refer to Field Supplied Drain section for instructions on field supplied/installed drain on outlet of furnace trap. Hose#7 Hose#8 Figure 32 COUNTERFLOW MODEL INSTALLED HORIZONTAL- LY WITH LEFT SIDE DOWN (SEE FIGURE 33) r *Also see Front Cover Pressure Switch Tube Location on page 11. Minimum 5 112"clearance is required for the drain trap be- neath the furnace. Figure 31 NOTE: For horizontal installations, some of the required hoses are found in the factory-installed hose assemblies. 22 Remove the hose clamps to obtain the respective hoses Hose#4 needed for installation,and install per the following directions. 1. Remove the factory installed drain trap and hose assemblies. Leave the 100' elbow inserted and clamped in the vent-drain elbow. 2. Remove two 1"plugs from left side of cabinet 3. (Draining the Collector Box) Remove the cap from o the left side of the collector box drain port (bottom in e horizontal left position)and install it on right side drain port. 4. Place radius end of hose#4 (factory installed)on the collector box drain port and secure with a silver clamp. 5. Insert hose #2 from outside the cabinet in the front Hose#4 Hoye#5 Hose#2 drain hole. 6. Connect hose#4 &hose#2 together using a straight barbed coupling and two gold clamps (factory Figure 33 installed). 7. (Draining the Vent Elbow) Remove rubber plug from ELECTRICAL CONNECTIONS vent—drain elbow side port. WIRING HARNESS 8. The unused vent-drain elbow drip leg port must be plugged to prevent flue gases from escaping_Insert The wiring harness is an integral part of this furnace. Wires rubber plug removed in step 7 into the 100°elbow. are color coded for identification purposes. Refer to the (Inserting a blunt tool such as a 3/16"Allen wrench wiring diagram for wire routings. If any of the original wire into the center of the rubber plug will stretch the plug as supplied with the furnace must be replaced, it must be and allow complete insertion) replaced with wiring material having a temperature rating of 9. Place radius end of hose #4 on the side port of vent at least 105' C. Any replacement wiring must be a copper —drain elbow and secure with a gold clamp. conductor. 10. Insert a '/2" diameter PVC pipe (factory installed) into AWARNING hose#4 and secure with a gold clamp. 11.Insert the non-grommet end of hose #5 (factory HIGH VOLTAGE ! installed) from outside the cabinet in the back drain TO AVOID THE RISK OF ELECTRICAL SHOCK,WIRING TO hole. THE UNIT MUST BE POLARIZED AND GROUNDED. 12. Insert 1000 elbow in hose #5 and secure with a red clamp. A WARNING 13. Locate hose#4 and cut a cut off a 4" straight section HIGH VOLTAGE ! and discard the radius end. 14. Connect the 4"straight section of hose#4 to the 1000 TO AVOID PERSONAL INJURY OR DEATH DUE TO elbow and the PVC pipe and secure with red clamps. ELECTRICAL SHOCK,DISCONNECT ELECTRICAL POWER 15. Connect the hoses to the trap inlets and secure with BEFORE SERVICING OR CHANGING ANY ELECTRICAL silver clamps,drain trap outlet must point to the original WIRING. bottom of the furnace. 16.1-Ising the two sheet metal screws provided in the ACAUTION cabinet, secure the trap to the furnace. LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING 17. Refer to Field Supplied Drain section for instructions on CONTROLS.WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS field supplied /installed drain on outlet of furnace trap. OPERATION.VERIFY PROPER OPERATION AFTER SERVICING. 115 VOLT LINE CONNECTIONS Before proceeding with electrical connections, ensure that the supply voltage,frequency, and phase correspond to that specified on the unit rating plate. Power supply to the furnace must be NEC Class 1, and must comply with all applicable codes. The furnace must be electrically grounded in accor- dance with local codes or, in their absence, with the latest edition of The National Electric Code,ANSI NFPA 70 and / or The Canadian Electric Code CSA C22.1. 23 Use a separate fused branch electrical circuit containing prop- 3. Relocate junction box and associated plugs and erly sized wire,and fuse or circuit breaker. The fuse or circuit grommets to opposite side panel. Secure with screws breaker must be sized in accordance with the maximum removed in step 2. overcurrent protection specified on the unit rating plate. An electrical disconnect must be provided at the furnace location. To ensure proper unit grounding,the ground wire should run from the furnace ground screw located inside the furnace Connect hot, neutral, and ground wires as shown in the wir- junction box all the way back to the electrical panel. NOTE: ing diagram located on the unit's blower door. Metal conduit Do not use gas piping as an electrical ground. To confirm is not considered a substitute for an actual ground wire to proper unit grounding, turn off the electrical power and per- the unit. For direct vent applications, the cabinet opening to form the following check. the junction box must be sealed air tight using either an UL approved bushing such as Heyco Liquid Tight or by applying 1. Measure resistance between the neutral (white) non-reactive UL approved sealant to bushing. connection and one of the burners. Line polarity must be observed when making field connec- 2. Resistance should measure 10 ohms or less. tions. Line voltage connections can be made through either This furnace is equipped with a blower door interlock switch the right or left side panel.The furnace is shipped configured which interrupts unit voltage when the blower door is opened for a left side electrical connection with the junction box for servicing. Do not defeat this switch. located inside the burner compartment. To make electri- cal connections through the opposite side of the furnace, 24 VOLT THERMOSTAT WIRING the junction box must be relocated to the other side of the IMPORTANT NOTE burner compartment prior to making electrical connections. To relocate the junction box, follow the steps shown below. WIRE ROUTING MUST NOT INTERFERE WITH CIRCULATOR BLOWER NOTE: Wire routing must not to interfere with circulator OPERATION, FILTER REMOVAL OR ROUTINE MAINTENANCE. blower operation, filter removal, or routine maintenance. JUNCTION BOX RELOCATION Low voltage connections can be made through either the right or left side panel. Thermostat wiring entrance holes Aare located in the blower compartment. The following figure WARNING shows connections for a "heat/cool system". EDGES OF SHEET METAL HOLES MAY BE SHARP. USE GLOVES AS A This furnace is equipped with a 40 VAtransformer to facilitate PRECAUTION WHEN REMOVING HOLE PLUGS. use with most cooling equipment. Consult the wiring diagram, located on the blower compartment door, for further details A WARNING of 115 Volt and 24 Volt wiring. TO PREVENT PERSONAL INJURY OR DEATH DUE TO ELECTRIC SHOCK, 000(�Ql ROOM THERMOSTAT DISCONNECT ELECTRICAL POWER BEFORE INSTALLING OR SERVICING THIS UNIT. W2 w/w R G C v/vi YZ INTEGRATED FURNACE CONTROL MODULE A WARNING REMOTE COOLING UNIT HIGH VOLTAGE ! C Y (SINGLE STAGE) TO AVOID THE RISK OF INJURY,ELECTRICAL SHOCK OR DEATH,THE FURNACE MUST BE ELECTRICALLY Thermostat-Single-Stage Heating with Single-Stage GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN Cooling THEIR ABSENCE,WITH THE LATEST EDITION OF THE NOTE:To apply a single-stage Heating Thermostat,the thermostat selector switch on the Integrated Control Module must be set on NATIONAL ELECTRIC CODE. single-stage. Figure 34 Line voltage connections can be made through either the right or left side panel.The furnace is shipped configured for a left W2 w/wi R G C Y ROOM THERMOSTAT side electrical connection. To make electrical connections through the opposite side of the furnace, the junction box W2 w/wi R G C v/vi Y2 INTEGRATED FURNACE CONTROL MODULE must be relocated to the left side prior to making electrical connections. To relocate the junction box, perform the fol- C Y REMOTE COOLING UNIT lowing Steps. (SINGLE STAGE) 1. Remove the burner compartment door. 2. Remove and save the two screws securing the junction Thermostat-Two-Stage Heating with Single-Stage Cooling box to the side panel. Thermostat- Two-Stage Heating with Single-Stage Cooling Figure 35 24 uses an outdoor temperature sensor to determine the most wz wi R G C Yl Y2 ROOM THERMOSTAT cost efficient means of heating (heat pump or gas furnace). A heat pump thermostat with three stages of heat is required W2 w/wt R G C v/vi y2 INTEGRATED FURNACE to properly use a two-stage furnace in conjunction with a heat CONTROL MODULE p p y g J pump. Refer to the fossil fuel kit installation instructions for C Y1 Y2 REMOTE COOLING UNIT additional thermostat requirements. (TWO STAG E) Strictly follow the wiring guidelines in the fossil fuel kit instal- Thermostat-Two-Stage Heating with Two-Stage Cooling lation instructions. All furnace connections must be made Thermostat- Two-Stage Heating with Two-Stage Cooling to the furnace two-stage integrated control module and the Thermostat Wiring Diagrams "FURNACE"terminal strip on the fossil fuel control board. Figure 36 TWINNING SINGLE-STAGE HEATING THERMOSTAT Two furnaces of the same model may be twinned. The in- tegrated control board has a 3/16" terminal labeled "TWIN" APPLICATION located beside the low voltage thermostat connection strip. A single-stage heating thermostat may be used to control Twinning allows simultaneous operation of two furnaces and this furnace, however the furnace is setup by default to use a forces the indoor blower motors of each furnace to operate two-stage heating thermostat.To use a single stage heating synchronously into a common duct system. Using the twin- thermostat the installer must make the desired selections ning function will require only field installed wiring with no in the user menus using the push button switches on the external kits or parts. control board. The staging and speed tap options must be set the same . When a single stage heating thermostat is used there are on both furnaces. two options for controlling the timed NOTE: Each furnace must be connected to it's own 115 VAC • Press the Left or Right menu switch to get to the A H S power supply. The L1 connection to each furnace must be menu. in phase (connected to circuit breakers on the same 115 VAC service panel phase leg). To verify that the furnaces • The menu will display these options; no 10 20 30 60 AUt are in phase, check from L1 to L1 on each furnace with a voltmeter. If the furnaces are in phase,the voltage between • Fixed time options are expressed in minutes on the both furnaces will be ZERO. display as;10 20 30 60. • If AUt (Automatic) is selected, the actual timing for the FURNACE 2 w2 w/wi R G C Y/Y2 Y2 TWIN transition to 2nd stage heat will be calculated by the control board based on length of run time of previous heating cycles (duty cycle). TWIN • Press the center switch to save the selection. FURNACE 1 w2 w/wi R G C Y/Y1 Y2 In Auto mode, the transition to 2nd stage heat will vary be- tween 1 to 12 minutes ROOM THERMOSTAT wz w/wi R G C v/vi Y2 Timing to 2nd Duty Cycle 0/0Stage Gas Heat Demand COND UNIT 0-38 12 minutes Llght CONTACTOR COND UNIT Light to CONTACTOR 39-50 10 minutes Average�— Figure 37 51-62 7 minutes Averaa_e 115 VOLT LINE CONNECTION OF ACCESSORIES 63-75 5 minutes Average (HUMIDIFIER AND ELECTRONIC AIR CLEANER) to Heavy 76-88 3 minutes Heavy The furnace integrated control module is equipped with line voltage accessory terminals for controlling power to an op- tional field-supplied humidifier and/or electronic air cleaner. FOSSIL FUEL APPLICATIONS The accessory load specifications are noted in the chart below: This furnace can be used in conjunction with a heat pump in a fossil fuel application. A fossil fuel application refers to Humidifier 1.0 Amp maximum at 120 VAC a combined gas furnace and heat pump installation which Electronic Air Cleaner 1.0 Amp maximum at 120 VAC 25 Turn OFF power to the furnace before installing any acces- Note: This is a 24 volt circuit only, the common connection sories. Follow the humidifier or air cleaner manufacturers' must be on C terminal of the low voltage terminal strip(where instructions for locating, mounting,grounding,and controlling thermostat wires are connected). Wiring for this circuit must these accessories. Accessory wiring connections are to be NOT be connected to the line N location where line voltage made through the 1/4" quick connect terminals provided on neutral wires are connected. the furnace integrated control module. The humidifier and electronic air cleaner hot terminals are identified as HUM H ° ° vas. and EAC H.The humidifier and electronic air cleaner neutral terminals are identified as NEUTRAL. All field wiring must ' conform to applicable codes. Connections should be made 24V HUM as shown. °O Terminal is If it is necessary for the installer to supply additional line s°s°10 ° ° energized when voltage wiring to the inside of the furnace, the wiring must ... 0®o pressure switch conform to all local codes,and have a minimum temperature : ® a one is closed rating of 105°C. All line voltage wire splices must be made inside the furnace junction box. °°°° The integrated control module humidifier terminal (HUM 24 VOLT HUM. H) is energized with 115 volts whenever the induced draft ®®ems & HUMIDISTAT blower is energized.The integrated control module electron is air cleaner terminal (EAC H) is energized with 115 volts W2 W/W1 RG JYM Y2 whenever the circulator blower is energized. This terminal Accessories-Accessories Wiring can also be used to provide 115 volt power to a humidifier transformer. The remaining primary transformer wire would GAS SUPPLY AND PIPING be connected to the Line N on the control board. AWARNING A WARNING TO AVOID POSSIBLE UNSATISFACTORY OPERATION OF EQUIPMENT HIGH VOLTAGE ! DAMAGE DUE TO UNDERFIRING OR EQUIPMENT,USE THE PROPER SIZE TO AVOID PERSONAL INJURY OR DEATH DUE TO OF NATURAL/PROPANE GAS PIPING NEEDED WHEN RUNNING PIPE FROM ELECTRICAL SHOCK,DISCONNECT ELECTRICAL POWER THE METER/TANK TO THE FURNACE. BEFORE SERVICING OR CHANGING ANY ELECTRICAL WIRING. INLET GAS SUPPLY PRESSURE 115 VAC EAC Natural Gas Minimum: 4.5"w.c. Maximum: 10.0"w.c. 115 VAC HUM Propane Gas Minimum: 11.0"w.c. Maximum: 13.0"w.c. The furnace rating plate includes the approved furnace gas o input rating and gas types. The furnace must be equipped o ®® ®® o to operate on the type of gas applied.This includes any con- version kits required for alternate fuels and/or high altitude. Inlet gas supply pressures must be maintained within the °° ranges specified in the adjacent table. The supply pressure 9 p 1 pp Y ° must be constant and available with all other household gas fired appliances operating. The minimum gas supply pres- o®o ® B coo sure must be maintained to prevent unreliable ignition. The ° ® One 0 maximum must not be exceeded to prevent unit overfiring. °°°o o o 0 o HIGH ALTITUDE DERATE When this furnace is installed at high altitude,the appropriate �®W2 W/W1 R GC Y/Y1 Y2 High Altitude orifice kit must be applied.This is required due to the natural reduction in the density of both the gas fuel 24 VOLT HUMIDIFIER CONNECTION and combustion air as altitude increases.The kit will provide the proper design certified input rate within the specified The furnace integrated control module is equipped with altitude range. a low voltage terminal for providing power to an optional field-supplied 24 volt humidifier. The 24V HUM terminal is High altitude kits are purchased according to the installation energized any time the draft inducer is powered. See con- altitude and usage of either natural or propane gas. Consult nection diagram below. the furnace Specification Sheet for appropriate kits. 26 Do not derate the furnace by adjusting the manifold pressure The gas valve has a manual ON/OFF control located on the to a lower pressure than specified on the furnace rating plate. valve itself. This control may be set only to the"ON"or"OFF" The combination of the lower air density and a lower manifold position. Refer to the lighting instructions label or Startup pressure will prohibit the burner orifice from drawing the prop- Procedure &Adjustment for use of this control during start er amount of air into the burner.This may cause incomplete up and shut down periods. combustion, flashback, and possible yellow tipping. GAS PIPING CONNECTIONS In some areas the gas supplier may artificially derate the gas in an effort to compensate for the effects of altitude. If the The gas piping supplying the furnace must be properly sized gas is artificially derated,the appropriate orifice size must be based on the gas flow required, specific gravity of the gas, determined based upon the BTU/ft3 content of the derated and length of the run. The gas line installation must comply gas and the altitude. Refer to the National Fuel Gas Code, with local codes,or in their absence,with the latest edition of NFPA54/ANSI Z223.1, and information provided by the gas the National Fuel Gas Code, NFPA 54/ANSI Z223.1. Natural Gas Capacity of Pipe supplier to determine the proper orifice size. In Cubic Feet of Gas Per Hour(CFH) A different pressure switch may be required at high altitude pength of Nominal Black Pipe Size p y q g R e in Feet 1/2" 3/4" 1" 1 1/4" 1 1/2" regardless of the BTU/ft3 content of the fuel used. Consult 10 132 278 520 1050 1600 the furnace Specification Sheet for pressure switch. 20 92 190 350 730 1100 30 73 152 285 590 980 A WARNING 40 63 1 245 0 0 50 56 115 15 215 44 440 67 670 60 50 1 105 1 195 1 400 1 610 POSSIBLE PROPERTY DAMAGE,PERSONAL INJURY OR DEATH MAY 70 46 96 180 370 560 OCCUR IF THE CORRECT CONVERSION KITS ARE NOT INSTALLED.THE 80 43 90 170 350 530 APPROPRIATE KITS MUST BE APPLIED TO ENSURE SAFE AND PROPER 90 40 84 160 320 490 FURNACE OPERATION.ALL CONVERSIONS MUST BE PERFORMED BY A 100 38 79 150 305 460 (Pressure 0.5 psig or less and pressure drop of 0.3"W.C.;Based on QUALIFIED INSTALLER OR SERVICE AGENCY. 0.60 Specific Gravity Gas) CFH= BTUH Furnace Input PROPANE GAS CONVERSION Heating Value of Gas(BTU/Cubic Foot) This unit is configured for natural gas, but may be converted for use with L.P.gas. Refer to the section on PROPANE GAS/ To connect the furnace to the building's gas piping,the install- HIGH ALTITUDE INSTALLATIONS for L.P. kit selection. er must supply a ground joint union, drip leg, manual shutoff valve, and line and fittings to connect to gas valve. In some When converting to LP gas, it is recommended that an cases,the installer may also need to supply a transition piece LPLPO" kit also be installed. The use of this kit will prevent from 1/2" pipe to a larger pipe size. the furnace from firing when the LP gas supply pressure is too low to support proper combustion. The following stipulations apply when connecting gas piping. Refer to Gas Piping Connections figure for typical gas line Consult the furnace Specification Sheet for a listing of appro- connections to the furnace. priate kits.The indicated kits must be used to insure safe and proper furnace operation. All conversions must be performed Gas piping must be supported external to the furnace by a qualified installer, or service agency. cabinet so that the weight of the gas line does not distort the burner rack, manifold or gas valve. ACAUTION • Use black iron or steel pipe and fittings for building TO PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE,THE piping. Where possible, use new pipe that is properly INLET GAS SUPPLY PRESSURE MUST BE AS SPECIFIED ON THE UNIT chamfered,reamed,and free of burrs and chips. If old RATING PLATE WITH ALL OTHER HOUSEHOLD GAS FIRED APPLIANCES pipe is used, be sure it is clean and free of rust,scale, OPERATING. burrs, chips, and old pipe joint compound. • Use pipe joint compound on male threads ONLY. GAS VALVE Always use pipe joint compound (pipe dope) that is APPROVED FOR ALL GASES. DO NOT apply This unit is equipped with a 24 volt gas valve controlled compound to the first two threads. during furnace operation by the integrated control module. • Use ground joint unions. As shipped,the valve is configured for natural gas. The valve . Install a drip leg to trap dirt and moisture before it can is field convertible for use with propane gas by replacing the enter the gas valve. The drip leg must be a minimum regulator spring with a propane gas spring from an appro- of three inches long. priate manufacturer's propane gas conversion kit. Taps for measuring the gas supply pressure and manifold pressure Install a 1/8" NPT pipe plug fitting, accessible for test are provided on the valve. gage connection, immediately upstream of the gas supply connection to the furnace. 27 • Always use a back-up wrench when making the Alternate Manifold Burners Manual Shut Off Valve Gas Line (upstream from connection to the gas valve to keep it from turning. Location ground joint The orientation of the gas valve on the manifold must ` I pipe union) e r be maintained as shipped from the factory. Maximum o torque for the gas valve connection is 375 in-lbs; Gas Valve *Ground excessive over-tightening may damage the gas valve. Ground-0- a t—Joint Joint Pipe • Install a manual shutoff valve between the gas meter Pipe Union and unit within six feet of the unit. If a union is installed, Union F Drip Leg the union must be downstream of the manual shutoff p in Grommet Plug valve, between the shutoff valve and the furnace. g o 0 in Standard Alternate o o Gas Line • Tighten all joints securely. Gas Line Hole Hole u o • Connect the furnace to the building piping by one of the following methods: — Rigid metallic pipe and fittings. NOTE:Union maybe inside furnace cabinet where allowed by local codes. — Semi-rigid metallic tubing and metallic fittings. UPFLOW Aluminum alloy tubing must not be used in exterior Figure 39 locations. In order to seal the grommet cabinet Gas Connections penetration, rigid pipe must be used to reach the outside of the cabinet. A semi-rigid connector to A WARNING the gas piping may be used from there. TO AVOID THE POSSIBILITY OF EXPLOSION OR FIRE, NEVER USE A MATCH • Use listed gas appliance connectors in accordance OR OPEN FLAME TO TEST FOR LEAKS. with their instructions. Connectors must be fully in the same room as the furnace. • Protect connectors and semirigid tubing against GAS PIPING CHECKS physical and thermal damage when installed. Ensure Before placing unit in operation, leak test the unit and gas aluminum-alloy tubing and connectors are coated to connections. protect against external corrosion when in contact with masonry, plaster, or insulation, or subjected to Check for leaks using an approved chloride-free soap and repeated wetting by liquids such as water(except rain water solution, an electronic combustible gas detector, or water), detergents, or sewage. other approved testing methods. The gas piping may enter the left or right side of the furnace NOTE: Never exceed specified pressures for testing. Higher cabinet. The installer must supply rigid pipe long enough to pressure may damage the gas valve and cause subsequent reach the outside of the cabinet to seal the grommet cabinet overfiring, resulting in heat exchanger failure. penetration. A semi-rigid connector to the gas piping can be Disconnect this unit and shutoff valve from the gas supply used outside the cabinet per local codes. 1/2" NPT pipe and piping system before pressure testing the supply piping sys- fittings are required. For models with an "L" shaped mani- tem with pressures in excess of 1/2 psig (3.48 kPa). fold,a 4 1/2"long nipple is required. For models with a hook shaped manifold, a 2" long nipple is required. Isolate this unit from the gas supply piping system by closing its external manual gas shutoff valve before pressure testing A semi-rigid connector to the gas piping can be used outside supply piping system with test pressures equal to or less than the cabinet per local codes. From the elbow,the length of pipe 1/2 psig (3.48 kPA). and the fittings required will vary by the side chosen, location of union and cabinet width. The union may be placed inside PROPANE GAS TANKS AND PIPING or outside of the cabinet.\ A WARNING IF THE GAS FURNACE IS INSTALLED IN A BASEMENT,AN EXCAVATED AREA OR CONFINED SPACE,IT IS STRONGLY RECOMMENDED TO CONTACT A PROPANE SUPPLIER TO INSTALL A GAS DETECTING WARNING DEVICE IN CASE OF A GAS LEAK. •SINCE PROPANE GAS IS HEAVIER THAN AIR,ANY LEAKING GAS CAN SETTLE IN ANY LOW AREAS OR CONFINED SPACES. • PROPANE GAS ODORANT MAY FADE,MAKING THE GAS UNDETECTABLE EXCEPT WITH A WARNING DEVICE. 28 A gas detecting warning system is the only reliable way to de- Aclosed return duct system must be used,with the return duct tect a propane gas leak. Rust can reduce the level of odorant connected to the furnace. NOTE: Ductwork must never be in propane gas. Do not rely on your sense of smell. Contact attached to the back of the furnace. For upflow installations a local propane gas supplier about installing a gas detecting requiring 1800 CFM or more, use either two side returns or warning system. If the presence of gas is suspected, follow bottom return or a combination of side/bottom. Flexible joints the instructions listed in the Safety Considerations section may be used for supply and return connections to reduce of this manual. noise transmission. To prevent the blower from interfering with combustion air or draft when a central return is used, a All propane gas equipment must conform to the safety connecting duct must be installed between the unit and the standards of the National Board of Fire Underwriters, NBFU utility room wall. Never use a room, closet, or alcove as a Manual 58. return air chamber. For satisfactory operation, propane gas pressure must be CHECKING DUCT STATIC 10" WC at the furnace manifold with all gas appliances in operation. Maintaining proper gas pressure depends on Refer to your furnace rating plate for the maximum ESP three main factors: (external duct static) rating. 1. Vaporization rate, depending on temperature of the AWARNING liquid, and "wetted surface" area of the container or containers. NEVER ALLOW THE PRODUCTS OF COMBUSTION,INCLUDING CARBON 2. Proper pressure regulation. (Two-stage regulation is MONOXIDE,TO ENTER THE RETURN DUCT WORK OR CIRCULATION AIR recommended for both cost and efficiency). SUPPLY. 3. Pressure drop in lines between regulators, and Total external static refers to everything external to the fur- between second stage regulator and the appliance. nace cabinet. Cooling coils, filters, ducts, grilles, registers Pipe size will depend on length of pipe run and total must all be considered when reading your total external static load of all appliances. pressure. The supply duct pressure must be read between Complete information regarding tank sizing for vaporiza- the furnace and the cooling coil. tion, recommended regulator settings, and pipe sizing is This reading is usually taken by removing the "A" shaped available from most regulator manufacturers and propane block off plate from the end on the coil; drilling a test hole gas suppliers. in it and reinstalling the block off plate. Take a duct static Since propane gas will quickly dissolve white lead and most reading at the test hole.Tape up the test hole after your test standard commercial compounds, special pipe dope must is complete. The negative pressure must be read between be used.Always use a pipe thread sealant approved for all the filter and the furnace blower. gases. Too much external static pressure will result in insufficient air Refer to the this illustration for typical propane gas installa- that can cause excessive temperature rise. This can cause tions and piping. limit switch tripping and heat exchanger failure. 5 to 15 PSIG To determine total external duct static pressure, proceed as First Stage (20 PSIG Max.) Regulator Continuous follows; 11"W.C. 1. With clean filters in the furnace,use a draft gauge(inclined 200 PSIG Second Stage manometer)to measure the static pressure of the return Maximum Regulato duct at the inlet of the furnace. (Negative Pressure) 2. Measure the static pressure of the supply duct. (Positive Pressure) Propane Gas Installation(Typ.) 3. The difference between the two numbers is .4"w.c. Figure 40 Example: CIRCULATING AIR & FILTERS static reading from return duct = -.1"w.c. DUCT WORK - AIR FLOW static reading from supply duct= .3"w.c. total external static pressure on this system = .4"w.c. Duct systems and register sizes must be properly designed for the CFM and external static pressure rating of the furnace. NOTE: Both readings may be taken simultaneously and read Design the ductwork in accordance with the recommended directly on the manometer if so desired. If an air conditioner methods of"Air Conditioning Contractors of America"Manual D. coil or Electronic Air Cleaner is used in conjunction with the furnace,the readings must also include theses components, Install the duct system in accordance with Standards of the as shown in the following drawing. National Board of Fire Underwriters for the Installation of Air Conditioning, Warm Air Heating and Ventilating Systems. 4. Consult proper tables for the quantity of air. Pamphlets No. 90A and 90B. 29 If the total external static pressure exceeds the maximum outlet air duct. This opening shall be accessible when the listed on the furnace rating plate, check for closed dampers, furnace is installed and shall be of such a size that the heat registers, undersized and/or oversized poorly laid out duct exchanger can be viewed for visual light inspection or such work. that a sampling probe can be inserted into the airstream. The temperature rise of the furnace must be within the tem- The access panel must be made to prevent air leaks whenthe furnace is in operation. perature rise range listed on the furnace rating plate. SUPPLY AIR p When the furnace is heating, the temperature of the return Q air entering the furnace must be between 55°F and 100°F. CUTAWAY OF DUCTWORK TO EXPOSE COIL CUT USING TIN SNIPS PRESS OUT By HAND C \ INCLINED Q MANOMETER CUT<REMOVINGSHEET AFT METAL B SCRIBE LINES OUTLINING OUT FLANGES RETURN AIR Duct Flange Cut Outs Figure 42 Checking Static Pressure FILTERS - READ THIS SECTION BEFORE INSTALLING Figure 41 THE RETURN AIR DUCT WORK A WARNING Filters must be used with this furnace.Discuss filter maintenance with the building owner. Filters do not ship with this furnace, but EDGES OF SHEET METAL HOLES MAY BE SHARP. USE GLOVES AS A must be provided,sized and installed externally by the installer. PRECAUTION WHEN REMOVING SHEET METAL FROM RETURN AIR Filters must comply with UL900 or CAN/ULCS111 standards. OPENINGS. Damage or repairs due to the installation of the furnace BOTTOM RETURN AIR OPENING without filters is not covered under the warranty. [UPFLOW MODELS] On upflow units, guide dimples locate the side return cutout locations. Use a straightedge to scribe lines connecting the dim- The bottom return air opening on upflow models utilizes a ples. Cut out the opening on these lines.NOTE:An undersized "lance and cut"method to remove sheet metal from the duct opening will cause reduced airflow. opening in the base pan. To remove, simply press out the lanced sections by hand to expose the metal strips retaining Refer to the following table to determine filter area require- the sheet metal over the duct opening. Using tin snips, cut ments. the metal strips and remove the sheet metal covering the Upflow Models Minimum Recommended Filter Size duct opening. In the corners of the opening, cut the sheet metal along the scribe lines to free the duct flanges. Using *M9C960303AN 1-16 X 25 Side or 1-14X 24 Bottom Return *M9C960403AN 1-16X25 Side orl-14X24 Bottom Return the scribe line along the duct flange as a guide, unfold the *M9C960603AN 1-16X25Sideor14X24 Bottom Return duct flanges around the perimeter of the opening using a pair *M9C960603BN 1-16X 25 Side or Bottom Return of seamer pliers or seamer tongs. *M9C960803BN 1-16X 25 Side or Bottom Return NOTE:Airflow area will be reduced by approximately 18% if *M9C960804CN 1-16X 25 Side or Bottom Return *M9C961004CN 2-16 X 25 Side or 1-20 X 25 Bottom Return duct flanges are not unfolded. This could cause performance *M9C961005CN 2-16X 25 Side or 1-20 X 25 Bottom Return Issues and noise Issues. *M9C961205DN 2-16 X 25 Side or 1-24 X 24 Bottom Return When the furnace is used in connection with a cooling unit, Downflow Models the furnace should be installed in parallel with or on the *C9C960403BN 2-10X20or1-14X25TopReturn upstream side of the cooling unit to avoid condensation in *C9C960603BN 2-10X20or1-14X25TopReturn the heating element. With a parallel flow arrangement, the *C9C960803BN 2-14X 20or 1-16X 25Top Return dampers or other means used to control the flow of air must *C9C961005CN 2-14X 20or 1-20X 25TopReturn be adequate to prevent chilled air from entering the furnace Larger filters may be used,filters may also be centrally located and, if manually operated, must be equipped with means to =Use 2-16X 25 filters and two side returns or 20X 25 filter on bottom return if furnace is connected to a cooling unit over 4tons nominal capacity prevent operation of either unit unless the damper is in the A combination of one side&bottom may be used instead of both sides full heat or cool position. When the furnace is installed without a cooling coil, it is rec- Change filters before occupants take ownership of a ommended that a removable access panel be provided in the new home! 30 UPRIGHT INSTALLATIONS NOTE; If the furnace bottom panel has not been removed for a return duct connection, all perforations must be sealed Depending on the installation and/or customer preference,differ- with duct sealant compound or other suitable method to ing filter arrangements can be applied. Filters can be installed prevent air leakage. For optimal performance verify that all in the central return register or a side panel external filter rack door gaskets are properly in place and replace as needed kit(upflows). As an alternative a media air filter or electronic air to prevent air leakage. cleaner can be used as the requested filter. Consider installing DRAIN TRAP PRIMING an air cleaner with deep-pleated media filter at the time of The drain trap MUST be primed prior to furnace startup. To furnace installation.Adeep-pleated filter with a MERV rating prime,fill both sides of the drain trap with water.This ensures of 8 (minimum) will often provide better filtration to protect proper furnace drainage upon startup and prohibits the equipment and the air distribution system than a standard 1" possibility of flue gases escaping through the drain system. filter and often has lower static pressure loss than a 1"filter. FURNACE OPERATION Also a deep-pleated filter will typically require less frequent replacement intervals.Avoid using highly restrictive 1"filters Purge gas lines of air prior to startup. Be sure not purge lines which produce static pressure loss greater than .25"W.C. In into an enclosed burner compartment. some installations the minimum filter size required will not Check for leaks using an approved chloride-free soap and lend itself to a filter installation on the side of the furnace. water solution, an electronic combustible gas detector, or The installation of a centrally installed air cleaner cabinet other approved method. Verify that all required kits(propane or a return duct filter installation may offer more practicality. gas, high altitude, etc.) have been appropriately installed. Clean ComfortTm brand MERV 11 air cleaners have 5'/4" FURNACE STARTUP media filters and are available in the following configura- 1. Close the manual gas shutoff valve external to the tions. Consult your distributor for information on our com- furnace. plete line of IAQ Clean ComfortTM products. 2. Turn off the electrical power to the furnace. 3. Set the room thermostat to the lowest possible setting. The figure below shows possible filter locations. 4. Remove the burner compartment door. HORIZONTAL INSTALLATIONS NOTE: This furnace is equipped with an ignition device which automatically lights the burner. Do not try to light the Filters must be installed in either the central return register or in burner by hand. the return air duct work. AIR FLOW 5. Move the furnace gas valve manual control to the OFF Q position. CENTRAL 6. Wait five minutes then smell for gas. Be sure check RETURN GRILLE near the floor as some types of gas are heavier than air. SIDE RETURN ® 7. If you smell as after five minutes, immediate) follow w EXTERNAL FILTER O Y 9 Y RACK KIT the Safety Considerations on page 2 of this manual. LL (EITHER SIDE) If you do not smell gas after five minutes, move the furnace gas valve manual control to the ON position. 8. Replace the burner compartment door. b 9. Open the manual gas shutoff valve external to the LL furnace. 10.Turn on the electrical power to the furnace. 11.Adjust the thermostat to a setting above room temperature. 12.After the burners are lit, set the thermostat to desired Figure 43 temperature. FURNACE SHUTDOWN STARTUP PROCEDURE & ADJUSTMENT 1. Set the thermostat to the lowest setting. Furnace must have a 115 VAC power supply properly con- The integrated control will close the gas valve and nected and grounded. Proper polarity must be maintained extinguish flame. Following a 15 second delay, the induced draft blower will be de-energized. The for correct operation. In addition to the following start-up and circulator blower will shut off after the time delay adjustment items, refer to further information in Operational expires (selectable 90, 120, 150, 180 seconds). Checks section. 2. Remove the burner compartment door and move the furnace gas valve manual control to the OFF position. FURNACE CABINET 3. Close the manual gas shutoff valve external to the Check that all furnace cabinet sealing components are in furnace. place (plugs, grommets, gaskets). 4. Replace the burner compartment door. 31 White-Rodgers 36J54 valve: Back outlet pressure GAS SUPPLY PRESSURE MEASUREMENT test screw (inlet/outlet pressure tap) out one turn (counterclockwise, not more than one turn). GAS PRESSURE TEST 4. Attach a hose and manometer to the outlet pressure The line pressure supplied to the gas valve must be within tap (White-Rodgers valve). the range specified below. The supply pressure can be mea- 5. Turn ON the gas supply. sured at the gas valve inlet pressure tap or at a hose fitting 6. Turn on power and close thermostat "R" and "W1" installed in the gas piping drip leg.The supply pressure must contacts to provide a call for low stage heat. be measured with the burners operating.To measure the gas 7. Measure the gas manifold pressure with burners firing. supply pressure, use the following procedure. Adjust manifold pressure using the Manifold Gas Pressure table shown below. 1. Turn OFF gas to furnace at the manual gas shutoff Manifold Gas Pressure valve external to the furnace. Gas I Range Nom inal 2. Connect a calibrated water manometer(or appropriate Natural Low Stage 1.6-2.2" w.c. 1.9"w.c. gas pressure gauge) at either the gas valve inlet High Stage 3.2- 3.8" w.c. 3.5"w.c. pressure tap or the gas piping drip leg. See White- Propane Low Stage 5.7-6.3" w.c. 6.0"w.c. Rodgers 36J54 gas valve figure for location of inlet High Stage 9.7- 10.3"w.c 10.0"w.c. pressure tap. 8. Remove regulator cover screw from the low (LO) outlet pressure regulator adjust tower and turn screw NOTE: If measuring gas pressure at the drip leg, afield- clockwise to increase pressure or counterclockwise to supplied hose barb fitting must be installed prior to making decrease pressure. Replace regulator cover screw. the hose connection. If using the inlet pressure tap on the g Close thermostat "R", "W1" and "W2" contacts to White-Rodgers 36J54 gas valve, then use the 36G/J Valve provide a call for high stage heat. Pressure Check Kit, Part No. 0151 KOOOOOS. 10.Remove regulator cover screw from the high (HI) 3. Turn ON the gas supply and operate the furnace and outlet pressure regulator adjust tower and turn screw all other gas consuming appliances on the same gas clockwise to increase pressure or counterclockwise to supply line. decrease pressure. Replace regulator cover screw. 4. Measure furnace gas supply pressure with burners 11. Turn off all electrical power and gas supply to the firing. Supply pressure must be within the range system. specified in the Inlet Gas Supply Pressure table. 12.Remove the manometer hose from the hose barb fitting If supply pressure differs from table, make the necessary or outlet pressure tap. adjustments to pressure regulator,gas piping size,etc.,and/ 13.Replace outlet pressure tap: or consult with local gas utility. White-Rodgers 36J54 valve: Turn outlet pressure 5. Turn OFF gas to furnace at the manual shutoff valve test screw in to seal pressure port (clockwise, 7 in-lb and disconnect manometer. Reinstall plug before minimum). turning on gas to furnace. 14.Turn on electrical power and gas supply to the system. 6. Turn OFF any unnecessary gas appliances stated in 15.Close thermostat contacts "R" and "W1/W2" to step 3. energize the valve. GAS MANIFOLD PRESSURE MEASUREMENT AND Using a leak detection solution or soap suds, check for ADJUSTMENT leaks at outlet pressure tap plug (Honeywell valve)or screw ACAUTION (White-Rodgers valve). Bubbles forming indicate a leak. SHUT OFF GAS AND REPAIRALL LEAKS IMMEDIATELY! TO PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE,THE NOTE: For gas to gas conversion, consult your dealer for GAS MANIFOLD PRESSURE MUST BE AS SPECIFIED ON THE UNIT RATING appropriate conversion. PLATE. ONLY MINOR ADJUSTMENTS SHOULD BE MADE BY ADJUSTING THE GAS VALVE PRESSURE REGULATOR. �0 Only small variations in gas pressure should be made by INLET ► ► OUTLET adjusting the gas valve pressure regulator. The manifold e° pressure must be measured with the burners operating. To Ps 0 ao measure and adjust the manifold pressure, use the following O procedure. 1. Turn OFF gas to furnace at the manual gas shutoff Gas Valve On/Off valve external to the furnace. Selector Switch 2. Turn off all electrical power to the system. White-Rodgers Model 36J54(Two-Stage) 3. Outlet pressure tap connections: 32 GAS INPUT RATE MEASUREMENT (NATURAL GAS 3. Subtract the return air temperature from the supply ONLY) air temperature to determine the air temperature rise. Allow adequate time for thermometer readings to INLET GAS SUPPLY PRESSURE stabilize. NATURAL GAS Minimum: 4.5"w.c. Maximum: 10.0"w.c. 4. Adjust temperature rise by adjusting the circulator PROPANE GAS Minimum: 11.0"w.c. Maximum: 13.0"w.c. blower speed. Increase blower speed to reduce temperature rise. Decrease blower speed to increase temperature rise. Refer to Startup Procedure and The actual gas input rate to the furnace must never be greater Adjustment - Circulator Blower Speeds for speed than that specified on the unit rating plate. To measure natural changing details. gas input using the gas meter, use the following procedure. 1. Turn OFF the gas supply to all other gas-burning CROSS-HATCHED AREA SUBJECTED TO appliances except the furnace. RADIANT HEAT.DO NOT MEASURE 2. While the furnace is operating at high fire rate, time SUPPLY AIR TEMPERATURE IN THIS AREA. and record one complete revolution of the gas meter SUPPLY dial measuring the smallest quantity, usually the dial AIR that indicates 1/2 cu. ft. per revolution. You will use TSUPPLY this number to calculate the quantity of gas in cubic ft. if the furnace would consume if it ran steadily for one hour(3600 seconds). 'F7 p MEASURE 3. If the 1/2 cu.ft.dial was used, multiply your number x 2. 0 HERE RISE=T SUPPLY - T RETURN EXAMPLE: If it took 23 seconds to complete one revolution of the 1/2 ft. dial (23 x 2 =46). 0 T RETURN This tells us that at this rate, it would take 46 seconds to consume one cu. ft. of gas. 3600/46 = 78. RETURN AIR This tells us that in one hour, the furnace would consume 78 cu. ft. of gas. Temperature Rise Measurement The typical value range for 1 cu. ft. of natural gas is around Figure 45 1000 BTU. Check with your gas utility, if possible. In this example, the furnace is consuming 78,000 BTUH. AWARNING NOTE: The final manifold pressure cannot vary TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK, by more than ±0.3"w.c. for Natural and ±0.5"for TURN OFF POWER TO THE FURNACE BEFORE CHANGING SPEED TAPS. LP from the specified setting. Consult your local gas supplier if additional input rate adjustment is BLOWER HEAT OFF DELAY TIMINGS required. 4. Turn ON gas to and relight all other appliances The integrated control module provides a selectable heat off turned off in step 1. Be certain that all appliances delay function. The heat off delay period may be set to 90, are functioning properly and that all pilot burners are 120, 150, 180 seconds. The delay is factory shipped at 150 operating. seconds but may be changed to suit the installation require- ments and/or homeowner preference. TEMPERATURE RISE Temperature rise must be within the range specified on the unit rating plate. An incorrect temperature rise may result in condensing in or overheating of the heat exchanger. An airflow and temperature rise table is provided in the Specifi- cation Sheet applicable to your model. Determine and adjust temperature rise as follows: 1. Operate furnace with burners firing for approximately ten minutes. Ensure all registers are open and all duct dampers are in their final (fully or partially open) position. 2. Place thermometers in the return and supply ducts as close to the furnace as possible. Thermometers must not be influenced by radiant heat by being able to "see"the heat exchanger. 33 AIRFLOW TABLE LOW STAGE COOLING AIFLOW HIGH STAGE COOLING AIFLOW THERMOSTAT EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) THERMOSTAT EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) MODEL CALL TAPq 0.1 1 0.2 1 0.3 0.4 0.5 1 0.6 1 0.7 0.8 MODEL CALL TAPp 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM I CFM I CFM CFM CFM I CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM FO1 727 677 623 565 510 455 403 351 F01 727 677 623 565 510 455 403 351 F02 923 882 841 798 752 704 660 614 F02 923 882 841 798 752 704 660 614 F03 632 574 510 448 388 332 277 234 F03 632 574 510 448 388 332 277 234 F04^ 878 839 797 751 701 653 607 561 F04 878 839 797 751 701 653 607 561 *C9C960403BN Y/Y1 F05 1106 1076 1044 1010 974 939 899 860 *C9C960403BN Y2 F05^ 1106 1076 1044 1010 974 939 899 860 F06 1188 1156 1123 1091 1062 1029 998 964 F07 1237 1205 1174 1145 1115 1081 1050 1016 F06 1188 1156 1123 1091 1062 1029 998 964 F0S 1281 1252 1222 1195 1163 1134 1104 1071 F07 1237 1205 1174 1145 1115 1081 1050 1016 F09 1382 1354 1327 1302 1276 1246 1219 1190 FO8 1281 1252 1222 1195 1163 1134 1104 1071 FO1 1167 1118 1069 1022 974 928 877 833 F09 1382 1354 1327 1302 1276 1246 1219 1190 F02 1332 1289 1245 1200 1160 1120 1081 1036 FO1 1167 1118 1069 1022 974 928 877 833 F03 680 609 532 460 397 337 252 201 F02 1332 1289 1245 1200 1160 1120 1081 1036 F04^ 903 839 783 719 661 601 546 497 F03 680 609 532 460 397 337 252 201 *C9C960603BN Y/Y1 F05 1248 1204 1159 1113 1071 1028 983 943 F F06 963 907 852 803 745 689 639 587 04 903 839 783 719 661 601 546 497 F07 1393 1348 1309 1267 1230 1189 1152 1116 *C9C960603BN Y2 F05^ 1248 1204 1159 1113 1071 1028 983 943 F08 1450 1407 1366 1330 1290 1251 1221 1186 F06 963 907 852 803 745 689 639 587 F09 1468 1436 1393 1359 1323 1285 1248 1210 F07 1393 1348 1309 1267 1230 1189 1152 1116 FO1 1167 1124 1087 1040 995 954 916 869 F08 1450 1407 1366 1330 1290 1251 1221 1186 F02 1317 1277 1240 1201 1161 1122 1081 1045 1 F09 1 1468 1436 1393 1359 1323 1285 1248 1210 F03 733 669 606 543 482 424 372 300 FO1 1167 1124 1087 1040 995 954 916 869 F04^ 1217 1174 1130 1086 1045 1003 962 925 F02 1317 1277 1240 1201 1161 1122 1081 1045 *C9C960803BN Y/Y1 F05 1300 1263 1225 1186 1142 1099 1062 1023 F03 733 669 606 543 482 424 372 300 F06 919 872 820 764 711 658 605 553 F04 1217 1174 1130 1086 1045 1003 962 925 F07 1126 1085 1042 998 953 910 866 824 F08 1375 1341 1301 1264 1226 1189 1154 1118 *C9C9608036N Y2 F05^ 1300 1263 1225 1186 1142 1099 1062 1023 F09 1440 1402 1366 1330 1295 1260 1224 1187 F06 919 872 820 764 711 658 605 553 FO1 1366 1307 1248 1188 1130 1069 1007 938 F07 1126 1085 1042 998 953 910 866 824 F02 1833 1785 1736 1688 1640 1593 1543 1497 F08 1375 1341 1301 1264 1226 1189 1154 1118 F03 1295 1230 1168 1105 1044 981 911 843 1F09 1440 1402 1366 1330 1295 1260 1224 1187 F04^ 1634 1578 1525 1471 1416 1363 1311 1265 F01 1366 1307 1248 1188 1130 1069 1007 938 *C9C961005CN Y/Y1 F05 2028 1994 1937 1899 1863 1814 1769 1724 F02 1833 1785 1736 1688 1640 1593 1543 1497 F06 1773 1721 1671 1621 1571 1521 1470 1421 F03 1295 1230 1168 1105 1044 981 911 843 F07 1908 1860 1813 1766 1720 1672 1624 1578 265 F08 1965 1919 1873 1829 1783 1736 1688 1643 F04 2028 1994 1937 1899 1863 1363 1769 1724 F09 2096 2053 2014 1973 1931 1890 1849 1803 *C9C961005CN Y2 FOS^ 1773 1721 1671 1621 1571 1521 1470 1424 F06 1773 1721 1671 1621 1571 1521 1470 1421 F07 1908 1860 1813 1766 1720 1672 1624 1578 CIRCULATION AIRFLOW F08 1965 1919 1873 1829 1783 1736 1698 1643 THERMOSTAT ti 0.EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) F09 2096 2053 2014 1973 1931 1890 1849 1803 MODEL TAP 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM I CFM I CFM CFM CFM CFM CFM CFM F01 727 677 623 565 510 455 403 351 F02 923 882 841 798 752 704 660 614 F03 632 574 510 448 388 332 277 234 F04 878 839 797 751 701 653 607 561 *C9C960403BN G F05 1106 1076 1044 1010 974 939 899 860 F06 1188 1156 1123 1091 1062 1029 998 964 F07 1237 1205 1174 1145 1115 1081 1050 1016 F08 1281 1252 1222 1195 1163 1134 1104 1071 F09 1382 1354 1327 1302 1276 1246 1219 1190 FO1 1167 1118 1069 1022 974 928 877 833 F02 1332 1289 1245 1200 1160 1120 1081 1036 F03 680 609 532 460 397 337 252 201 F04 903 839 783 719 661 601 546 497 *C9C960603BN G F05 1248 1204 1159 1113 1071 1028 983 943 F06 963 907 852 803 745 689 639 587 F07 1393 1348 1309 1267 1230 1189 1152 1116 F08 1450 1407 1366 1330 1290 1251 1221 1186 F09 1468 1436 1393 1359 1323 1285 1248 1210 FO1 1167 1124 1087 1040 995 954 916 869 F02 1317 1277 1240 1201 1161 1122 1081 1045 F03 733 669 606 543 482 424 372 300 F04 1217 1174 1130 1086 1045 1003 962 925 *C9C960803BN G F05 1300 1263 1225 1186 1142 1099 1062 1023 fF06 919 872 820 764 711 658 605 553 F07 1126 1085 1042 998 953 910 866 824 FOS 1375 1341 1301 1264 1226 1189 1154 1118 F09 1440 1402 1366 1330 1295 1260 1224 1187 FO1 1366 1307 1248 1188 1130 1069 1007 938 F02 1833 1785 1736 1688 1640 1593 1543 1497 F03 1295 1230 1168 1105 1044 981 911 843 F04 1634 1578 1525 1471 1416 1363 1311 1265 *C9C961005CN G F05 2028 1994 1937 1899 1863 1814 1769 1724 F06 1773 1721 1671 1621 1571 1521 1470 1421 F07 1908 1860 1813 1766 1720 1672 1624 1578 F08 1 1965 1 1919 1873 1829 1783 1736 1688 1643 F09 1 2096 2053 2014 1 1973 1 1931 1 1890 1849 1803 Note: ADefault speed 34 AIRFLOW TABLE HEATING AIFLOW EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) THERMOSTAT TEMP RANGE TEMP RANGE MODEL CALL TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 LOW HIGH CFM RISE CFM I RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM F01^ 727 34 677 37 623 40 565 44 510 49 455 403 351 W/W1 F03^^ 632 N/A 574 N/A 510 N/A 448 N/A 388 N/A 332 277 234 F04 878 28 839 30 797 31 751 33 701 36 653 607 561 *C9C9604036N 20-50 25-55 F02^ 923 39 882 40 841 42 798 45 752 47 704 660 614 W2 F04 878 41 839 42 797 45 751 47 701 51 653 607 561 F05 1106 32 1076 33 1044 34 1010 35 974 37 939 899 860 F01^ 1167 32 1118 33 1069 35 1022 37 974 38 928 877 833 W/W1 F03^^ 680 N/A 609 N/A 532 N/A 460 N/A 397 N/A 337 252 201 *C9C960603BN F04^^ 903 N/A 839 N/A 783 N/A 719 N/A 661 N/A 601 546 497 20-50 25-55 F02^ 1332 40 1289 41 1245 43 1200 44 1160 46 1120 1081 1036 W2 F04^^ 903 N/A 839 N/A 783 N/A 719 N/A 661 N/A 601 546 497 F05 1248 43 1204 44 1159 46 1113 48 1071 50 1028 983 943 F01^ 1167 43 1124 44 1087 46 1040 48 995 50 954 916 869 W/W1 F03^^ 733 N/A 669 N/A 606 N/A 543 N/A 482 N/A 424 372 300 *C9C960803BN F04 1217 41 1174 42 1130 44 1086 46 1045 48 1003 962 925 30-60 40-70 F02^ 1317 54 1277 56 1240 57 1201 59 1161 61 1122 1081 1045 W2 F04 1217 58 1174 61 1130 63 1086 65 1045 68 1003 962 925 F05 1300 55 1263 56 1225 58 1186 60 1142 62 1099 1062 1023 F01^ 1366 46 1307 48 1248 50 1188 52 1130 55 1069 1007 938 W/W1 F03 1295 48 1230 51 1168 53 1105 56 1044 58 981 911 843 F04^^ 1634 N/A 1578 N/A 1525 N/A 1471 N/A 1416 N/A 1363 1311 1265 *C9C961005CN 30-60 35-65 F02^ 1833 48 1785 50 1736 51 1688 53 1640 54 1593 1543 1497 W2 F04 1634 54 1578 56 1525 58 1471 60 1416 62 1363 1311 1265 F05 2028 44 1994 45 1937 46 1899 47 1863 48 1814 1769 1724 Note: "Default speed AA Not recommended for heating 35 AIRFLOW TABLE LOW STAGE COOLING AIFLOW HIGH STAGE COOLING AIFLOW THERMOSTAT EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) THERMOSTAT EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) MODEL CALL TAP# 0.1 0.2 1 0.3 0.4 1 0.5 1 0.6 0.7 0.8 MODEL CALL TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM I CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM F01 753 708 663 616 568 513 470 423 FOl 753 708 663 616 568 513 470 423 F02 915 883 845 809 773 730 690 650 F02 915 883 845 809 773 730 690 650 F03 529 518 461 394 343 288 223 N/A F03 529 518 461 394 343 288 223 N/A F04^ 880 843 807 768 723 683 643 590 F04 880 843 807 768 723 683 643 590 *M9C960303AN Y/Y1 F05 1055 1022 990 959 930 891 858 825 *M9C960303AN Y2 F05^ 1055 1022 990 959 930 891 858 825 F06 1101 1072 1040 1010 980 949 918 1 881 1 F06 1101 1072 1040 1010 1 980 949 918 881 F07 1190 1162 1134 1104 1077 1042 1013 982 F07 1190 1162 1134 1104 1077 1042 1013 982 F08 1229 1206 1178 1153 1128 1100 1070 04 FO8 1183 1157 1130 1103 1077 1047 1018 988 F09 1229 1206 1178 1153 1128 1100 1070 1042 F01 733 691 650 602 553 498 448 402 F09 1229 1206 1178 1153 1128 1100 1070 1042 F02 1051 1024 996 966 935 907 868 836 F01 733 691 650 602 553 498 448 402 F03 665 620 570 517 462 407 359 309 F02 1051 1024 996 966 935 907 868 836 F04^ 915 881 846 814 780 737 695 652 F03 665 620 570 517 462 407 359 309 *M9C960403AN Y/Y1 FOS 1138 1114 1092 1064 1035 1006 977 947 F04 915 881 846 814 780 737 695 652 F06 887 855 1 823 790 751 705 666 608 *M9C960403AN Y2 F05^ 1 1138 1114 1 1092 1064 1035 1006 977 947 F07 1189 1163 1138 1111 1085 1059 1032 1001 F06 887 855 823 790 751 705 666 608 F08 1266 1243 1218 1197 1172 1148 1123 1099 F07 1189 1163 1138 1111 1085 1059 1032 1001 F09 1342 1324 1305 1280 1263 1239 1216 1193 F01 900 867 830 798 758 718 682 645 F08 1266 1243 1218 1197 1172 1148 1123 1099 F02 1292 1272 1248 1227 1206 1184 1162 1137 F09 1342 1324 1305 1280 1263 1239 1216 1193 F03 688 649 603 551 499 447 405 359 F01 900 867 830 798 758 718 682 645 F04^ 866 830 797 759 717 675 634 591 F02 1292 1272 1248 1227 1206 1184 1162 1137 *M9C960603AN Y/Y1 F05 1223 1195 1176 1149 1124 1101 1074 1047 F03 688 649 603 551 499 447 405 359 F06 1037 1004 975 950 921 886 853 823 F04 866 830 1 797 1 759 717 675 634 591 F07 1079 1053 1025 1000 970 941 911 873 *M9C960603AN Y2 F05^ 1223 1195 1176 1149 1124 1101 1074 1047 F08 1128 1099 1075 1050 1022 993 965 937 F06 1037 1004 975 950 921 886 853 823 F09 1171 1148 1124 1096 1070 1045 1017 988 F07 1079 1053 1025 1000 970 941 911 873 FO1 914 864 815 762 704 654 604 560 F08 1128 1099 1075 1050 1022 993 965 937 F02 1121 1083 1041 996 953 906 861 818 F03 758 696 636 572 512 460 412 N/A F09 1171 1148 1124 1096 1070 1045 1017 988 F04^ 960 917 864 812 764 708 661 614 FO1 914 864 815 762 704 654 604 560 *M9C960603BN Y/Y1 F05 1164 1123 1084 1042 1003 960 920 871 F02 1121 1083 1041 996 953 906 861 818 F06 1219 1180 1141 1102 1062 1020 978 940 F03 758 696 636 572 512 460 412 N/A F07 1273 1240 1207 1171 1128 1089 1051 1012 F04 960 917 864 812 764 708 661 614 F08 1307 1270 1235 1198 1160 1122 1083 1043 *M9C960603BN Y2 F05^ 1164 1123 1084 1042 1003 960 920 871 F09 1427 1390 1362 1327 1297 1260 1224 1193 F06 1219 1180 1141 1102 1062 1020 978 940 FO1 1205 1169 1131 1091 1053 1014 974 934 F07 1273 1240 1207 1171 1128 1089 1051 1012 F02 1415 1385 1355 1322 1291 1255 1219 1186 FO8 1307 1270 1235 1198 1160 1122 1083 1043 F03 696 635 568 500 442 390 336 255 F09 1427 1390 1362 1327 1297 1260 1224 1193 F04^ 1152 1112 1076 1035 996 954 916 868 F01 1205 1169 1131 1091 1053 1014 974 934 *M9C960803BN Y/Y1 F05 1321 1287 1251 1217 1181 1146 1112 1072 F02 1415 1385 1355 1322 1291 1255 1219 1186 r 901 851 801 746 690 638 587 543 F03 696 635 568 500 442 390 336 255 1112 1076 1032 992 949 905 858 819 F04 1152 1112 1076 1035 996 954 916 868 1290 1252 1215 1182 1143 1107 1071 1032 *M9C960803BN Y2 F05^ 1321 1287 1251 1217 1181 1146 1112 1072 1471 1440 1409 1377 1347 1314 1283 1247 F06 901 851 801 746 690 638 587 543 F01 1289 1234 1180 1122 1058 991 917 840 F07 1112 1076 1032 992 949 905 858 819 F02 1836 1784 1741 1703 1664 1628 1585 1537 F08 1290 1252 1215 1182 1143 1107 1071 1032 F03 1297 1246 1199 1142 1083 1020 949 872 1 F09 1471 1440 1409 1377 1347 1314 1283 1247 F04^ 1194 1137 1079 1014 948 873 792 712 FO1 1289 1234 1180 1122 1058 991 917 840 *M9C960804CN Y/Y1 FOS 1748 1696 1650 1612 1574 1526 1478 1428 F02 1836 1784 1741 1703 1664 1628 1585 1537 F06 1451 1399 1354 1309 1256 1200 1142 1077 F03 1297 1246 1199 1142 1083 1020 949 872 F07 1587 1534 1489 1445 1406 1354 1298 1244 F04 1194 1137 1079 1014 948 1 873 1 792 712 F08 1683 1633 1589 1546 1502 1460 1406 1355 *M9C960804CN Y2 F05^ 1748 1696 1650 1612 1574 1 1526 1 1478 1428 F09 1919 1890 1946 1807 1771 1735 1694 1650 1 F06 1451 1399 1354 1309 1256 1 1200 1 1142 1077 FO1 1475 1421 1369 1314 1260 1207 1152 1097 F07 1587 1534 1489 1445 1406 1354 1298 1244 F02 1791 1741 1699 1652 1609 1561 1513 1465 TFO5� 1710 1633 1589 1546 1502 1460 1406 1355 F03 924 846 767 684 606 529 463 398 1890 1846 1807 1771 1735 1694 1650 F04^ 1259 1197 1138 1074 1015 947 885 821 1421 1369 1314 1260 1207 1152 1097 *M9C961004CN Y/Y1 F05 1710 1660 1613 1583 1517 1470 1421 1374 1741 1699 1652 1609 1561 1513 1465 F06 1592 1536 1486 1436 1383 1331 1281 1233 846 767 684 606 529 463 398 F07 1627 1574 1524 1474 1423 1370 1320 1271 1197 1138 1074 1015 947 885 821 F08 1921 1879 1840 1791 1751 1705 1656 1610 *M9C961004CN Y2 1660 1613 1583 1517 1470 1421 1374 F09 2026 1981 1929 1901 1858 1819 1773 1733 1536 1486 1436 1383 1331 1281 1233 F07 1627 1574 1524 1474 1423 1370 1320 1271 F01 1259 1197 1138 1074 1015 947 885 821 FO8 1921 1879 1840 1791 1751 1705 1656 1610 F02 1791 1741 1699 1652 1609 1561 1513 1465 F09 2026 1981 1929 1901 1858 1819 1773 1733 F03 1176 1108 1044 980 913 845 779 718 FO1 1259 1197 1138 1074 1015 947 885 821 F04^ 1347 1286 1231 1172 1115 1055 995 933 F02 1791 1741 1699 1652 1609 1561 1513 1465 *M9C961005CN Y/Y1 F05 1921 1879 1840 1791 1751 1705 1656 1610 F03 1176 1108 1044 980 913 845 779 718 F06 1446 1404 1335 1280 1226 1171 1117 1062 F04 1347 1286 1231 1172 1115 1055 995 933 F07 1618 1567 1510 1460 1413 1364 1312 1262 *M9C961005CN Y2 FOS^ 1921 1879 1840 1791 1751 1705 1656 1610 F08 2009 1964 1918 1886 1852 1811 1759 1722 1F06 1446 1404 1335 1280 1226 1171 1117 1062 F09 2161 2122 2084 2048 2010 1973 1940 1914 F07 1618 1567 1510 1460 1413 1364 1312 1262 FO1 1766 1712 1666 1612 1558 1506 1450 1395 F08 2009 1964 1918 1886 1852 1811 1759 1722 F02 2205 2157 2110 2064 2021 1974 1925 1879 F09 2161 2122 2084 2048 2010 1973 1940 1914 F03 1118 1035 952 860 750 663 590 519 F01 1766 1712 1666 1612 1558 1506 1450 1395 F04^ 1684 1620 1561 1499 1438 1378 1318 1259 F02 2205 2157 2110 2064 2021 1974 1925 1879 *M9C961205DN Y/Y1 FOS 2031 1981 1933 1901 1850 1799 1750 1702 F03 1118 1035 952 860 750 663 590 519 F06 1220 1145 1070 995 952 907 811 725 F04 1684 1620 1561 1499 1438 1378 1318 1259 F07 1357 1311 1243 1 1175 1107 1021 1 932 1 861 *M9C961205DN Y2 F05^ 2031 1981 1933 1901 1850 1799 1750 1702 F08 1906 1877 1828 1778 1726 1 1674 1622 1568 F06 1220 1145 1070 995 952 907 811 725 F09 1 2454 2396 2347 2296 2250 1 2202 2157 2113 F07 1357 1311 1243 1175 1107 1021 932 861 F08 1906 1877 1828 1778 1726 1 1674 1622 1568 Note: ^Default speed F09 2454 2396 2347 2296 2250 1 2202 1 2157 36 AIRFLOW TABLE CIRCULATION AIRFLOW THERMOSTAT EXTERNALSTATIC PRESSURE,(INCHES WATER COLUMN) MODEL CALL TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM FO1 753 708 663 616 568 513 470 423 F02 915 883 845 809 773 730 690 650 F03 529 518 461 394 343 288 223 N/A F04 880 843 807 768 723 683 643 590 *M9C960303AN G F05 1055 1022 990 959 930 891 858 825 F06 1101 1072 1040 1010 980 949 918 881 F07 1190 1162 1134 1104 1077 1042 1013 982 F0S 1183 1157 1130 1103 1077 1047 1018 988 F09 1229 1206 1178 1153 1128 1100 1070 1042 F01 733 691 650 602 553 498 448 402 F02 1051 1024 996 966 935 907 868 836 F03 665 620 570 517 462 407 359 309 F04 915 881 946 814 780 737 695 652 *M9C960403AN G F05 1138 1114 1092 1064 1035 1006 977 947 F06 887 855 823 790 751 705 666 608 F07 1189 1163 1138 1111 1085 1059 1032 1001 FO8 1266 1243 1218 1197 1172 1148 1123 1099 F09 1342 1324 1305 1280 1263 1239 1216 1193 F01 900 867 830 798 758 718 682 645 F02 1292 1272 1248 1227 1206 1184 1162 1137 F03 688 649 603 551 499 447 405 359 F04 866 830 797 759 717 675 634 591 *M9C960603AN G F05 1223 1195 1176 1149 1124 1101 1074 1047 F06 1037 1004 975 950 921 886 853 823 F07 1079 1053 1025 1000 970 941 911 873 F08 1128 1099 1075 1050 1022 993 965 937 F09 1171 1148 1124 1096 1070 1045 1017 988 F01 914 864 815 762 704 654 604 560 F02 1121 1083 1041 996 953 906 861 818 F03 758 696 636 572 512 460 412 N/A F04 960 917 864 812 764 708 661 614 *M9C960603BN G F05 1164 1123 1084 1042 1003 960 920 871 F06 1219 1180 1141 1102 1062 1020 978 940 F07 1273 1240 1207 1171 1128 1089 1051 1012 F08 1307 1270 1235 1198 1160 1122 1083 1043 F09 1427 1390 1362 1327 1297 1260 1224 1193 F01 1205 1169 1131 1091 1053 1014 974 934 F02 1415 1385 1355 1322 1291 1255 1219 1186 F03 696 635 568 500 442 390 336 255 F04 1152 1112 1076 1035 996 954 916 868 *M9C960803BN G F05 1321 1287 1251 1217 1181 1146 1112 1072 F06 901 851 801 746 690 638 587 543 F07 1112 1076 1032 992 949 905 858 819 FO8 1290 1252 1215 1182 1143 1107 1071 1032 F09 1471 1440 1409 1377 1347 1314 1283 1247 FO1 1289 1234 1180 1122 1058 991 917 840 F02 1836 1784 1741 1703 1664 1628 1585 1537 F03 1297 1246 1199 1142 1083 1020 949 872 F04 1194 1137 1079 1014 948 873 792 712 *M9C960804CN G F05 1748 1696 1650 1612 1574 1526 1478 1428 F06 1451 1399 1354 1309 1256 1200 1142 1077 F07 1587 1534 1489 1445 1406 1354 1298 1244 FOS 1683 1633 1589 1546 1502 1460 1406 1355 F09 1919 1890 1846 1807 1771 1735 1694 1650 FO1 1475 1421 1369 1314 1260 1207 1152 1097 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 924 846 767 684 606 529 463 398 F04 1259 1197 1138 1074 1015 947 885 821 *M9C961004CN G F05 1710 1660 1613 1583 1517 1470 1421 1374 F06 1592 1536 1486 1436 1383 1331 1281 1233 F07 1627 1574 1524 1474 1423 1370 1320 1271 F08 1921 1879 1840 1791 1751 1705 1656 1610 F09 2026 1981 1929 1901 1858 1819 1773 1733 F01 1259 1197 1138 1074 1015 947 885 821 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 1176 1108 1044 980 913 845 779 718 F04 1347 1286 1231 1172 1115 1055 995 933 *M9C961005CN G F05 1921 1879 1840 1791 1751 1705 1656 1610 F06 1446 1404 1335 1280 1 1226 1 1171 1117 1062 F07 1618 1567 1510 1460 1413 1364 1312 1262 FOS 2009 1964 1918 1886 1852 1811 1759 1722 F09 2161 2122 2094 2048 2010 1973 1940 1914 FO1 1766 1712 1666 1612 1558 1506 1450 1395 F02 2205 2157 2110 2064 2021 1974 1925 1879 F03 1118 1035 952 860 750 663 590 519 F04 1684 1620 1561 1499 1438 1378 1318 1259 *M9C961205DN G F05 2031 1981 1933 1901 1850 1799 1750 1702 F06 1220 1145 1070 995 952 907 811 725 F07 1357 1311 1243 1175 1107 1021 932 861 F08 1906 1877 1828 1778 1726 1674 1622 1568 F09 2454 2396 2347 2296 2250 2202 2157 2113 Note: ^Default speed 37 AIRFLOW TABLE HEATING AIFLOW THERMOSTAT EXTERNALSTATIC PRESSURE,(INCHES WATER COLUMN) TEMP RANGE TEMP RANGE MODEL CALL TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 LOW HIGH CFM RISE CFM RISE CFM RISE CFM RISE CFM ENWE CFM CFM CFM F01^ 753 25 708 26 663 28 616 30 568 33 513 470 423 W/W1 F03^^ 529 N/A 518 N/A 461 N/A 394 N/A 343 N/A 288 223 N/A *M9C960303AN F04 880 21 843 22 807 23 768 24 723 26 683 643 590 20-50 20-50 F02^ 915 29 883 30 845 32 809 33 773 34 730 690 650 W2 F04 880 30 843 32 807 33 768 35 723 37 683 643 590 F05 1055 25 1022 26 990 27 959 28 930 29 891 858 825 F01^ 733 34 691 36 650 38 602 41 553 45 498 448 402 W/W1 F03^^ 665 N/A 620 N/A 570 N/A 517 N/A 462 N/A 407 359 309 *M9C960403AN F04 915 1 27 881 28 846 29 814 31 780 32 737 695 652 20-50 20-50 F02^ 1051 34 1024 35 996 36 966 37 935 38 907 868 836 W2 F04 915 39 881 40 846 42 814 44 780 46 737 695 652 F05 1138 31 1114 32 1092 33 1064 33 1035 34 1006 977 947 FO1^ 900 40 867 42 830 44 798 46 758 48 718 682 645 W/W1 F03^^ 688 N/A 649 N/A 603 N/A 551 N/A 499 N/A 447 405 359 *M9C960603AN F04 866 42 830 44 797 46 759 48 717 50 675 634 591 20-50 30-60 F02^ 1292 41 1272 42 1248 43 1227 43 1206 44 1184 1162 1137 W2 F04^^ 866 N/A 830 N/A 797 N/A 759 N/A 717 N/A 675 634 591 F05 1223 44 1195 45 1176 45 1149 46 1124 47 1101 1074 1047 FO1^ 914 41 864 43 815 46 762 49 704 53 654 604 560 W/W1 F03^^ 758 N/A 696 N/A 636 N/A 572 N/A 512 N/A 460 412 N/A *M9C960603BN F04 960 39 917 41 864 43 812 46 764 49 708 661 614 25-55 35-65 F02^ 1121 48 1083 49 1041 51 996 54 953 56 906 861 818 W2 F04^^ 960 N/A 917 N/A 864 N/A 812 N/A 764 N/A 708 661 614 F05 1164 46 1123 47 1084 49 1042 51 1003 53 960 920 871 FO1^ 1205 41 1169 43 1131 44 1091 46 1053 47 1014 974 934 W/W1 F03^^ 696 N/A 635 N/A 568 N/A 500 N/A 442 N/A 390 336 255 *M9C960803BN F04 1152 43 1112 45 1076 46 1035 48 996 50 954 916 868 35-65 35-65 F02^ 1415 50 1385 51 1355 52 1322 54 1291 55 1255 1219 1186 W2 F04^^ 1152 N/A 1112 N/A 1076 N/A 1035 N/A 996 N/A 954 916 868 F05 1321 54 1287 55 1251 57 1217 58 1181 60 1146 1112 1072 FO1^ 1289 39 1234 40 1180 42 1122 44 1058 47 991 917 840 W/W1 F03 1297 38 1246 40 1199 42 1142 44 1083 46 1020 949 872 *M9C960804CN F04 1194 42 1137 44 1079 46 1014 49 948 52 873 792 712 25-55 25-55 F02^ 1836 39 1784 40 1741 41 1703 42 1664 43 1628 1585 1537 W2 F04^^ 1194 N/A 1137 N/A 1079 N/A 1014 N/A 948 N/A 873 792 712 F05 1748 41 1696 42 1650 43 1612 44 1574 45 1526 1478 1428 FO1^ 1475 42 1421 44 1369 45 1314 47 1260 49 1207 1152 1097 W/W1 F03^^ 924 N/A 846 N/A 767 N/A 684 N/A 606 N/A 529 463 398 *M9C961004CN F04 1259 49 1197 52 1138 55 1074 58 1015 61 947 885 821 35-65 35-65 F02^ 1791 50 1741 51 1699 52 1652 54 1609 55 1561 1513 1465 W2 F04^^ 1259 N/A 1197 N/A 1138 N/A 1074 N/A 1015 N/A 947 885 821 F05 1710 52 1660 54 1613 55 1583 56 1517 1 59 1470 1421 1374 FO1^ 1259 49 1197 52 1138 55 1074 58 1015 61 947 885 821 W/W1 F03^^ 1176 N/A 1108 N/A 1044 N/A 980 N/A 913 N/A 845 779 718 *M9C961005CN F04 1347 46 1286 48 1231 51 1172 53 1115 56 1055 995 933 35-65 35-65 F02^ 1791 50 1741 51 1699 52 1652 54 1609 55 1561 1513 1465 W2 F04^^ 1347 N/A 1286 N/A 1231 N/A 1172 N/A 1115 N/A 1055 995 933 F05 1921 46 1879 47 1840 48 1791 50 1751 51 1705 1656 1610 FO1^ 1766 42 1712 44 1666 45 1612 46 1558 1 48 1506 1450 1395 W/W1 F03^^ 1118 N/A 1035 N/A 952 N/A 860 N/A 750 N/A 663 590 519 *M9C961205DN F04 1684 44 1620 46 1561 48 1499 50 1438 52 1378 1318 1259 35-65 35-65 F02^ 2205 48 2157 49 2110 51 2064 52 2021 53 1974 1925 1879 W2 FO4^^ 12 N/A 1620 N/A 1561 N/A 1499 N/A 1438 N/A 1378 1318 1259 F05 20311 53 1981 54 1 1933 1 55 1 1901 56 1850 58 1799 1750 1702 Note: ADefault speed AA Not recommended for heating 38 NORMAL SEQUENCE OF OPERATION 3. When the center switch is pressed,the current displayed speed shall be selected, and control shall the newly POWER UP selected speed in next heating call. Upon being powered up, the control board will perform in- Note: Always refer to the Heating Chart to choose from ternal and polarity checks.The control will display I d L, idle available heating speeds. mode until a call from the thermostat is received. THERMOSTAT CALL AVAILABLE SPEEDS CONTINUOUS FAN MODE SPEED SELECTION F01 (DEFAULT) When a 24 vac signal is present on the G terminal,the blower W/W1 F03 motor will operate on selected continuous blower speed.The F04 EAC-H will also be energized as long as the blower motor F02 (DEFAULT) is energized. W2 F04 When the R to G circuit is opened,the blower motor will shut F05 down if no other function requires blower motor operation. To change the main blower speed in circulation mode,follow HEATING MODE the following steps: Call for 1st Stage Heat 1. Press left or right switch until LED displays'T S d". Press center switch and the LED will display the selected speed On a call for heat, the thermostat contacts close & the number as Fxx(xx: Blower speed number from 01 to 09). control board receives 24 vac on the W1 terminal. SP3 is default speed for circulation. The control board microcomputer runs its self-check 2. The control will display an available speed number every routine. time Left/Right switches are pressed. All 9 speeds are The control verifies the limit switch is closed (24 vac on available for circulation. Pin 8 of the 12 Pin connector). 3. Press the center button to select the desired speed.The The control verifies that pressure switch circuit is open control will immediately apply that speed setting. (0 vac on Pin 5). THERMOSTAT AVAILABLE The control module performs a gas valve circuitry check CALL SPEEDS to verify gas valve relay state and presence of voltage SP1 at the valve. SP2 The system will energize the Induced draft blower. SP3 (DEFAULT The pre-purge period begins once the low fire pressure SP4 switch is detected closed. (24 vac on Pin 5). G SP5 After the completion of pre-purge, the control will ener- SP6 gize the igniter. SP7 After completion of the igniter warm-up period: SP8 SP9 The gas valve is energized. • The igniter is de-energized as soon as flame is sensed. • After 30 seconds the indoor blower is energized on HEATING MODE SPEED SELECTION heating speed. To change the main blower speed in HEATING mode,follow When using a single-stage heating thermostat the fur- the following steps: nace will transition to 2nd stage gas heat by either a fixed time or auto mode, depending on menu selections 1. Press left or right button till LED displays"gA1 "(for single made by the installer. stage HEATING) or "gA2 "(for Two stage HEATING). Press center button and LED will display the selected The inducer motor is enabled at high speed. speed number as Fxx(xx: Blower speed number). Closure of the second stage pressure switch will energize 2. The control shall rotate available speed number every the high fire stage of the gas valve. time Left/Right switches are pressed.Table below shows The 2nd stage gas heat speed of the indoor blower is the available speeds for Low& High heat mode. energized 39 -When the thermostat is satisfied; SINGLE STAGE COOLING SPEED TABLE FOR 2 STAGE IFC • The gas valve is de-energized. THERMOSTAT CALL AVAILABLE SPEEDS • The inducer remains energized for the post purge period F01 (15 seconds). F02 • The indoor blower runs for the selected off delay period F03 (90 seconds by default, adjustable from 30 — 180 sec- F04 onds). Y2 F05 (DEFAULT) Call for 2nd Stage Heat During 1 st Stage Heat Operation F06 • The control board receives a 24 vac signal on the W2 F07 terminal. F08 • The inducer motor is enabled at high speed. F09 • Closure of the second stage pressure switch will energize the high fire stage of the gas valve. TWO STAGE COOLING SPEED TABLE FOR 2 STAGE IFC • The 2nd stage gas heat speed of the indoor blower is COOLING MODE energized. Low Stage Cooling Mode Sequence: Note:A call for second stage without a call for first stage will be ignored. On a call for low stage cooling, the Y/Y1 or Y/Y1 and G ther- mostat contacts close signaling the furnace control board with 24 vac. on Y/Y1 or Y/Y1 and G terminals. COOLING MODE SPEED SELECTION The 7-Segment will display the cool mode; 1 A C To change the main blower speed in COOLING mode,follow The compressor and condenser fan are energized. the following steps: The circulator fan is energized at low cool speed after 1. Press left or right button till LED displays"AC1 "(for single a cool on delay. The electronic air cleaner will also be stage COOLING) or "AC2 "(for Two stage COOLING). energized.After the thermostat is satisfied,the compres- Press center button and LED will display the selected sor is de-energized and the Cool Mode Fan Off Delay speed number as Fxx (xx: Blower speed number from period begins. 1 to 9). Following the Cool Mode Fan Off Delay period, the cool 2. The control shall rotate available speed number every circulator and air cleaner relay are de-energized. time Left/Right switches are pressed. All 9 speeds are 2nd Stage Cooling Mode Sequence: available for both Single and Two Stage cooling. 3. When the center switch is pressed,the current displayed On a call for 2nd stage cooling,the Y2 orY2 and G thermostat speed shall be selected,and control shall apply the newly contacts close signaling the furnace control board with 24 selected speed in next cooling call. vac. on Y2 or Y2 and G terminals. THERMOSTAT CALL AVAILABLE SPEEDS The 7-Segment will display the cool mode; 2 A C F01 The compressor and condenser fan are energized. F02 The circulator fan is energized at cool speed after a cool F03 on delay.The electronic air cleanerwill also be energized. F04 (DEFAULT) After the thermostat is satisfied,the compressor is de-en- Y/Y1 F05 ergized and the Cool Mode Fan Off Delay period begins. F06 Following the Cool Mode Fan Off Delay period, the cool F07 circulator and air cleaner relay are de-energized. F08 OPERATIONAL CHECKS F09 The burner flames should be inspected with the burner compartment door installed. Flames should be stable,quiet, soft,and blue(dust may cause orange tips but they must not be yellow). Flames should extend directly outward from the burners without curling, floating, or lifting off. Flames must not impinge on the sides of the heat exchanger firing tubes. 40 SAFETY CIRCUIT DESCRIPTION discharge.This procedure is applicable to both installed and uninstalled (ungrounded)furnaces. A number of safety circuits are employed to ensure safe and 1. Disconnect all power to the furnace. Do not touch the proper furnace operation.These circuits serve to control any integrated control module or any wire connected to the potential safety hazards and serve as inputs in the moni- control prior to discharging your body's electrostatic toring and diagnosis of abnormal function. These circuits charge to ground. are continuously monitored during furnace operation by the 2. Firmly touch a clean, unpainted, metal surface of the integrated control module. furnace away from the control. Any tools held in a INTEGRATED CONTROL MODULE person's hand during grounding will be discharged. The integrated control module will display furnace status 3. Service integrated control module or connecting including faults, mode of operation and air flow, on three wiring following the discharge process in step 2. Use seven segment displays. caution not to recharge your body with static electricity; (i.e., do not move or shuffle your feet, do not touch PRIMARY LIMIT ungrounded objects, etc.). If you come in contact with The primary limit control is located on the partition panel and an ungrounded object, repeat step 2 before touching monitors heat exchanger compartment temperatures. It is control or wires. a normally-closed (electrically), automatic reset, tempera- 4. Discharge your body to ground before removing a new ture-activated sensor. The limit guards against overheating control from its container. Follow steps 1 through 3 if as a result of insufficient conditioned air passing over the installing the control on a furnace. Return any old or heat exchanger. new controls to their containers before touching any AUXILIARY LIMIT ungrounded object. The auxiliary limit controls are located on or near the circula- DIAGNOSTIC CHART for blower and monitors blower compartment temperatures. Refer to the Troubleshooting Chart in the back of this manual They are a normally-closed (electrically), manual-reset sen- for assistance in determining the source of unit operational sors. These limits guard against overheating as a result of problems. insufficient conditioned air passing over the heat exchanger. External Lockout ROLLOUT LIMIT - A control lockout resulting from an external fault The rollout limit controls are mounted on the burner/manifold sensed by the control, such as an unsuccessful assembly and monitor the burner flame. They are normal- recycle or retry period, or a limit trip. Once in ly-closed (electrically), manual-reset sensors. These limits External Lockout, the control will shut down for a guard against burner flames not being properly drawn into period of one hour before attempting another trial the heat exchanger. for ignition. PRESSURE SWITCHES Internal Lockout - A failure internal to the control board. The pressure switches are normally-open (closed during operation) negative air pressure-activated switches. They FAULT RECALL monitor the airflow(combustion air and flue products)through the heat exchanger via pressure taps located on the induced Retrieving Fault Codes draft blower and the coil front cover. These switches guard RESETTING FROM LOCKOUT against insufficient airflow(combustion air and flue products) through the heat exchanger and/or blocked condensate drain Furnace lockout results when a furnace is unable to achieve conditions. ignition after three attempts during a single call for heat. It is FLAME SENSOR characterized by a non-functioning furnace and a one flash diagnostic LED code. If the furnace is in "lockout", it can be The flame sensor is a probe mounted to the burner/manifold reset in any of the following ways. assembly which uses the principle of flame rectification to 1. Automatic reset. The integrated control module will determine the presence or absence of flame. automatically reset itself and attempt to resume normal operations following a one hour lockout period. TROUBLESHOOTING 2. Manual power interruption. Interrupt 115 volt power to ELECTROSTATIC DISCHARGE (ESD) the furnace for 1 -20 seconds. PRECAUTIONS 3. Manual thermostat cycle. Lower the thermostat so that there is no longer a call for heat then reset to previous Use the following precautions during furnace installation setting. Interrupt thermostat signal to the furnace for and servicing to protect the integrated control module from 1 - 20 seconds. damage. By putting the furnace, the control, and the person NOTE: If the condition which originally caused the lockout at the same electrostatic potential, these steps will help still exists, the control will return to lockout. Refer to the avoid exposing the integrated control module to electrostatic Troubleshooting Chart for aid in determining the cause. 41 MAINTENANCE FILTER REMOVAL AWARNING Depending on the installation, differing filter arrangements HIGH VOLTAGE ! can be applied. Filters can be installed in either the central return register or a side panel external filter rack (upflow EL AVOID PERSONAL INJURY DEATH DUE TO only). A media air filter or electronic air cleaner can be used ELECTRICAL SHOCK,DISCONNECT ELECTRICAL POWER as an alternate filter. Follow the filter sizes give n In the BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. Recommended Minimum Filter size table to ensure proper unit performance. ANNUAL INSPECTION To remove filters from an external filter rack in an upright The furnace should be inspected by a qualified installer, or upflow installation,follow the directions provided with external service agency at least once per year.This check should be filter rack kit. performed at the beginning of the heating season. This will HORIZONTAL UNIT FILTER REMOVAL ensure that all furnace components are in proper working order and that the heating system functions appropriately. Filters in horizontal installations are located in the central Pay particular attention to the following items. Repair or return register or the ductwork near the furnace. service as necessary. To remove: • Flue pipe system. Check for blockage and/or 1. Turn OFF electrical power to furnace. leakage. Check the outside termination and the 2. Remove filter(s) from the central return register or connections at and internal to the furnace. ductwork. • Heat exchanger.Check for corrosion and/or buildup 3. Replace filter(s) by reversing the procedure for within the heat exchanger passageways. removal. • Burners. Check for proper ignition, burner flame, 4. Turn ON electrical power to furnace. and flame sense. • Drainage system. Check for blockage and/or MEDIA AIR FILTER OR ELECTRONIC AIR CLEANER leakage. Check hose connections at and internal REMOVAL to furnace. • Wiring. Check electrical connections for tightness Follow the manufacturer's directions for service. and/or corrosion. Check wires for damage. • Filters. AWARNING HIGH VOLTAGE ! AWARNING TO AVOID PERSONAL INJURY OR DEATH DUE TO TO AVOID ELECTRICAL SHOCK,INJURY OR DEATH, ELECTRICAL SHOCK,DISCONNECT ELECTRICAL POWER DISCONNECT ELECTRICAL POWER BEFORE PERFORMING ANY BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. MAINTENANCE. IF YOU MUST HANDLE THE IGNITER, HANDLE WITH CARE.TOUCHING THE IGNITER ELEMENT WITH BARE FINGERS,ROUGH HANDLING OR VIBRATION COULD DAMAGE THE IGNITER RESULTING IN PREMATURE FAILURE.ONLY A QUALIFIED SERVICER SHOULD EVER HANDLE THE IGNITER. Check the burner flames for: FILTERS 1.Stable,soft and blue 2.Not curling,floating,or lifting off. FILTER MAINTENANCE Improper filter maintenance is the most common cause of Burner Flame inadequate heating or cooling performance. Filters should Figure 47 be cleaned (permanent)or replaced (disposable)every two BURNERS months or as required. When replacing a filter, it must be replaced with a filter of the same type and size. Visually inspect the burner flames periodically during the heating season. Turn on the furnace at the thermostat and ACAUTION allow several minutes for flames to stabilize, since any dis- TO ENSURE PROPER UNIT PERFORMANCE,ADHERE TO THE FILTER SIZES lodged dust will alter the flames normal appearance. Flames GIVEN IN THE RECOMMENDED MINIMUM FILTER SIZE TABLE OR should be stable, quiet, soft, and blue (dust may cause or- SPECIFICATION SHEET APPLICABLE TO YOUR MODEL. ange tips but they must not be yellow). They should extend directly outward from the burners without curling,floating, or lifting off. Flames must not impinge on the sides of the heat exchanger firing tubes. 42 INDUCED DRAFT AND CIRCULATOR BLOWERS REPAIR AND REPLACEMENT PARTS The bearings in the induced draft blower and circulator blower • When ordering any of the listed functional parts, be motors are permanently lubricated by the manufacturer. No sure to provide the furnace model, manufacturing,and further lubrication is required. Check motor windings for serial numbers with the order. accumulation of dust which may cause overheating. Clean Although only functional parts are shown in the parts as necessary. list, all sheet metal parts, doors, etc. may be ordered CONDENSATE TRAP AND DRAIN SYSTEM (QUALI- by description. FIED SERVICER ONLY Parts are available from your distributor. Annuallyinspect the drain tubes, drain trap, and field-sup- • p p� p- Functional Parts List: plied drain line for proper condensate drainage. Check drain system for hose connection tightness, blockage, and leaks. Auxiliary Limit Switch Clean or repair as necessary. Blower Cutoff A WARNING Blower Housing Blower Motor TO AVOID ELECTRICAL SHOCK,INJURY OR DEATH, Blower Mounting Bracket DISCONNECT ELECTRICAL POWER BEFORE PERFORMING ANY MAINTENANCE. IF YOU MUST HANDLE THE IGNITER, Blower Wheel HANDLE WITH CARE.TOUCHING THE IGNITER ELEMENT Door Switch WITH BARE FINGERS,ROUGH HANDLING OR VIBRATION Flame Sensor COULD DAMAGE THE IGNITER RESULTING IN PREMATURE FAILURE. ONLY A QUALIFIED SERVICER SHOULD EVER Gas Manifold HANDLE THE IGNITER. Gas Valve FLAME SENSOR (QUALIFIED SERVICER ONLY) Heat Exchanger Igniter Under some conditions, the fuel or air supply can create a Induced Draft Blower nearly invisible coating on the flame sensor. This coating acts as an insulator causing a drop in the flame sense signal. Integrated Control Module If the flame sense signal drops too low the furnace will not Natural Gas Orifice sense flame and will lock out. The flame sensor should be carefully cleaned by a qualified servicer using steel wool. Pressure Switch Primary Limit Switch BEFORE LEAVING AN INSTALLATION Propane Gas Orifice • Cycle the furnace with the thermostat at least three Rollout Limit Switch times. Verify cooling and fan only operation. Transformer • Review the Owner's Manual with the homeowner and discuss proper furnace operation and maintenance. • Leave literature packet near furnace. 43 STATUS CODES LED Display Menu Description Main Notes Option Menu Menu Active Alarm menu Err EHH (�oc code numbers) Last 6 Faults L 6F EHH (w code numbers) Code Release Number Er CR Number Reset to Factory Default rFd JES_ no Blower Speed for Continous Fan Mode FSd FHH (�oc Blower Speed Number FOI,F02.. Blower Speed for 1 st Stage RE 1 FHH (w Blower Speed Compressor Mode Number 1701,F02.. Blower Speed for 2nd Stage ()cc Blower Speed Compressor Mode RC2 FHH Number F01,F02..) Default set at 7 Secs,Adjustments Cool On Delay End Delay,Seconds can be made in 7 Secs increments from 0 to 35 Secs Default set at 65 Secs,Adjustments Cool Off Delay E Fd Delay,Seconds can be made in 5 Secs increments from 0 to 120 Secs Blower Speed for 1 Gas Heat Mode 9R 1 FHH (�oc Blower Speed Number F01,F02..) Blower Speed for 1 Gas Heat Mode 9R2 FHH ()oc Blower Speed Number F01,F02.. Default set at 30 Secs,Adjustments Gas Heat On Delay 9nd Delay,Seconds can be made in 5 Secs increments from 5 to 30 Secs Default set at 90 Secs,Adjustments Gas heat Off Delay 9Fd Delay,Seconds can be made in 30 Secs increments from 30 to 180 Secs Refer to Section" Automatic Heat Staging-For Two no_ 0- 2D_ CHANGING Stage Control AHS 30_ 60_ RLL HEATINGMODE SETTING' Mode Main Menu Idle I dL Continous Fan FRn Compressor Cooling,Low IRE Stage Compressor Cooling,High 2RE Stage Gas heat,Low Stage 9H I Gas heat,High Stage 9H2 OEM test Mode EOL 44 TROUBLESHOOTING CHART Symptom SL EDs Fault Description Corrective Actions Symptom SLEDS Fault Description Corrective Actions Normal operation I dL Normal operation None Normal operation I dL Normal operation None Locate and correct gas interruption Furnace fails to High stage pressure switch Check front cover pressure switch operate on high circuit is closed at start of heating le. Diagnose and replace high stage operation and verify proper drainage stage;furnace g cycle. pressure switch if needed (hose,wiring,contact operation), operates normally EEO High stage pressure switch Furnace lockoutdue to an correct if necessary on low stage contacts sticking excessive number of ignition Replace orreali realign niter Induced draft Furnace fails to "retries" 3 total p g g Shorts pressure switch EEO ( ) blower operating circuit wiring Repair short in wiring operate Failure to establish flame Check flame sense signal,clean Loss offlameafter sensor if coated or oxidized Furnace fails to establishment Check flue piping for blockage, operate on high Inspect pressure switch hose, proper length,elbows,and stage;furnace repair/replace if necessary termination operates normally Verify proper induced draft blower on low stage performance Inspect flue and/or inlet air piping for Low stage pressure switch EE9 High stage pressure switch blockage,proper length,elbows, circuit is closed at start of circuit is not closed and termination heating cycle Check drain system,correct as Furnace fails to Replace low stage pressure switch Induced draft operate EE I Low stage pressure switch Repair short in wiring blower operating necessary contacts sticking Check induced draft blower Short in pressure switch circuit performance,correct as necessary wirin Low stage pressure switch Tighten or correct wiring connection circuit is not closed Inspect pressure switch hose, Polarityof 115 volt AC is Correct polarity,check and correct Pressure switch hose blocked repair/replace if necessary Furnace ace fails to reversed wiring if necessary pinched,or connected Poor unit ground operate Verify proper ground,correct if Inspect flue and/or inlet air piping for necessa e, l blockage, en th,elbows, Gas valve is not energized ry Induced draft g g Fumace fails to when it should be Check wiring in gas valve circuit blower runs Blocked flue and/or inlet air and termination EEb continuous) with EE2 pipe,blocked drains system or Check drains system,correct as operate y p ys Ys External Gas Valve Error Replace integrated control board no furnace weak induced draft blower necessary operation Check induced draft blower Furnace fails to Gas valve is energized when it Check wiring in gas valve circuit performance,correct as necessary operate EEL should not be Incorrect pressure switch set Internal gas valve error Replace integrated control board point or malfunctioning switch Cplaceasneedheck pressure switchoperation, contacts replace as needed Furnace fails to No 115 power to furnace or no Restore high voltage power to Loose or impropedyconnected operate. 24 volt power to integrated furnace and integrated control wiring Tighten or correct wiring connection control module. module. Check filters and ductwork for nonE Blown fuse or tripped circuit Correct condition which caused Primary limit circuit is open blockage Clean filters or remove Integrated control breaker fuse to open,replace fuse obstruction module LED displayprovtdes Integrated control module is Replace non-functional integrated Circulator blower thehInsu atexcent onditionedairover Crformheck rculatorblowerspeedand no signal non-functional control module. runs continuously the heat exchanger performance EE3 Blocked filters,restrictive Verify neutral wire connection to No furnace Furnace fails to Grounding fault ductwork,improper circulator Correct speed or replace blower E10 furnace8continuilytoground operation operate Poor neutral connection blower speed,orfailed motor ifnecessary source circulator blower motor Check for correct gas pressure Loose orim connected Furnace fails to Checkforcorrect burneralignment wiring in high limit circuit operate property Tighten or correct wiring connection EII Open rolloutswitch Check for and correct burner restriction Flame sensed with no call for Correct short at flame sensor or in Induced draft Furnace fails to Check for Ignitor wiring. blower and heat flame sensorwiring operate I EEr Ignitor Open Replace Dama edIgnitor circulator blower EEy Shortto ground inflame sense Furnace fails to EEJ Inducer relay Error Replace integrated control board runs continuously circuit Check for lingering orlazyflame operate No furnace Verify proper operation of gas valve Twinning feature Check for wiring connections. operation Lingering burnerflame Slow EEH TWIN Error closing gas valve notworking Replace integrated control board Open fuse Replace fuse Furnace fails to EEE Internal Faults or IRQ Loss in Replace integrated control board No furnace EES o erate Control Board operation Short in low voltage wiring Locate and correct short in low voltage wiring Flame sense micro amp signal is minimal Clean flame sensorifcoated or Flame sensor is oxidized Inspect for proper flame coated/oxclized sensoralignment Normal furnace EE6 Flame sensor incorrectly operation positioned in burnerfame Check inlet air piping for blockage, Lazy burner flame due to proper length,elbows,and im proper gas pressure or termination combustion air Compare currentgas pressure to rating plate and adjust as needed Problem with igniter circuit Check and correct wiring from integrated control module to igniter Improperly connected or Diagnose and replace shorted Furnace fails to EEL shorted igniter igniteras needed Verifyand correct operate Poor unit ground unit ground wiring if needed Igniter relayfault on integrated Check igniter output from control, control module Ireplace ifnecessary 45 WIRING DIAGRAM AZ � r-1 C ` -+I GND 1 5 VAC/10/60 HZ n r 1 POW ER SUPPLY WITH ID BLOWER TWO STAGE PRESSURE 1 OVERCURRENT HOT SWITCH ASSEMBLY { O �r L PROTECTION DEVICE Z O SURFACE m j IGNITER OR HIGH FIRE 0 K r 1 WARNING:DISCONNECT 4 POW ER BEFORE LOW FIRE p p PSWITCHE 1 N SERVICING.WIRING PRESSURE Np N A W TO UNIT MUST BE SWITCH DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. 2 1 CONNECTOR OR TO 115VACl 10I60 HZ POWER SUPPLY WITH HI 3 PU OVERCURRENT PROTECTION DEVICE m FLAME L GND N _ WARNING: I TWO STAGE C 2 GY 0 GY � SENSOR DISCONNECT POWER GAS VALVE PM 1 BR p BEFORE SERV ICING. (WHITE RODGER!) WIRING TO UN MUST BE PROPERLY POLARIZED AND DISCONNECT SOME UNITS MAY HAVE GROUNDED. 1 ROLL OUT SWITCH 1I PU PK�c '1 r) Q w DOOR JF SWITCH L J L J L J L AUTO RESET PRI MARV JUNCTION BOX QLIMITCONTROL RD 0 GND Q- 3 WH INDUCED INDOOR DRAFT CIRCMR ULATOR d z RD BLOWER BLWR y A BK No y Cam.) BURNER COMPARTMENT GND LINE NEUTRAL BLOWER COMPARTMENT R Z C C AUTO RESET O HUM-OUT r C p AUXILIARY HUMIDIFIER J NEUTRAL p LIMIT CONTROLI�F -D m HUM __-_ r y ELECTRONIC NEUTRAL y ,AI`CLEANJR r_ O p IND HI ID NEUTRAL O a0 O O � BLWR T. IND LO NEUTRAL LHOT SURFACE .0 W FS IGNITER FLAME SENSOR (1 y e _F LINE 115 VAC NEUTRAL y y i i ° - 40 VA "' TRANSFORMER L d 24 VAC O v) L z TH(3) L O LL O(e) M CL .tea OT IRLMANUAL SET ROLLOUT LIMITS ITCH L A R BL Tp AUTO RESET N I AUTO RESET AUX LIMIT PRIMARY LIMIT 3 OR RD +VDC O BK YL HLO(1) Q C RD LOW FIRE PRESS W J C C J�� U ]J ; I SWITCH J V) 0 A ° g W1 PS15 C NO JL) 11 C j � PISS(9) NO O O r p y a V2 To HIGH FIRE L READ CODES FROM LEFT TO RIGHT HLI(S) PRESS.SWTICH. = O N R I I�RD V 3 c MVL(10) O PM INTEGRATED CONTROL MODULE{ j n DEHUM MVH(4) C ' � <N< y- CC� N H I ZB W MVC(11) GAS VALVE TR(7)00 TO I R VL R DR ECM MTR BL j�GND Q DOO HARNESS TO CI MICRO- G GN z N a BK L BK RK INTEGRATED CONTROL MODULE c p p = II-.4i�A1 II //7777 3 NOTES: GND A 1.SETHEATANTICIPATOR ON ROOM THERMOSTA 0.7AMPS. 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED CHASSIS BLOWER WHEN IFMYO RVIC HEOR. CIRCULATOR BLOWER COMPARTMENT MIFAB OFTHE ORIGINAL WIREBER R SUPPLIED WEPLACED WITH HRIN FURNACE GROUND DOOR SWITCH =VITGAEMPERA ITMUSTIN ROFATLASTH WIRING MATERIAL (OPEN WHEN CONIDUCTORS ONLY. 4. RATING OF AT LEAST 105'C.USE COPPER DOOR OPEN 4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. TO AND LOCAL CODES. Status Seven segment Display S DEPRESS SWITCL THE LAST FOR MORE THAN 2 SECONDS WHILE MOST RECENT TO SN STANDBY $e # Se # Se# (NO THERMOSTAT INPUTS) Internal Faults or IRQ Loss E I E E COLOR CODES: EQUIPMENT GND 1-�7 Lockout Due to Excessive Retries RBC Ole E E 0 PK PINK FIELD GND 1 Low Stage Pressure Switch Stuck Closed E E 1 BR BROWN FIELD SPLICE �- Low Stage ressure Switch Open E E 2 H WHITE Open High Limit Switch E E 3 BL BLUE SWITCH(TEMP.) Flame Detected When no Flame Should be E E 4 R GY GRAY IGNITER M , D RED FUse E E 5 LYELLOW SWITCH(PRESS.) Flame Si nal E E 6 OR ORANGE OVERCURRENT Ignitor Relay Fault E E L PU PURPLE PROT.DEVICE L3 Hi h Sta a PfeSSure Switch Stuck Closed E E $ GN GREEN JUNCTION Hi h Sta a Pressure Switch O en E E g BK BLACK Reversed Line Polari or Groundin Error E E A TERMINAL INTERNAL Internal Gas Valve Error E E b INTEGRATED CONTROL External Gas Valve Error E E C PLUG CONNECTION Open Rollout Switch E 1 1 LOW VOLTAGE(24V) nitor Open E E N LOW VOLTAGE FIELD Inducer Relav Error E E I Myy HI VOLTAGE(115V) TWIN Error E E H HI VOLTAGE FIELD GROUNDING ERROR E 1 0 0140F02620-A Wiring is subject to change.Always refer to the wiring diagram on the unit for the most up-to-date wiring. 46 SPECIAL INSTRUCTIONS FOR PRODUCTS INSTALLED IN THE STATE OF MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 2. Product Approved side wall horizontally vented gas fueled in every dwelling, building or structure used in whole or in part for equipment installed in a room or structure separate from the residential purposes, including those owned or operated by the dwelling, building or structure used in whole or in part for Commonwealth and where the side wall exhaust vent termination residential purposes. is less than seven (7)feet above finished grade in the area of the venting,including but not limited to decks and porches,the following requirements shall be satisfied: VENT/FLUE TEE 1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment,the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an DISTANCE BETWEEN alarm and batteryback-up Is installed on the floor level where 5 COMBUSTION VENT AND GRADE p AIR INTAKE. the gas equipment is to be installed.In addition,the installing / plumber or gasfitter shall observe that a battery operated DISTANCE BETWEEN/ COMBUSTION AIR or hard wired carbon monoxide detector with an alarm is INTAKE AND GRADE J installed on each additional level of the dwelling,building or structure served by the side wall horizontal vented gas fueled , equipment.It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a. In the event that the side wall horizontally vented gas (c) MANUFACTURER REQUIREMENTS-GAS EQUIPMENT fueled equipment is installed in a crawl space or an attic, VENTING SYSTEM PROVIDED.When the manufacturer the hard wired carbon monoxide detector with alarm and of Product Approved side wall horizontally vented gas battery back-up may be installed on the next adjacent equipment provides a venting system design or venting floor level. system components with the equipment,the instructions b. In the event that the requirements of this subdivision can provided by the manufacturer for installation of the not be met at the time of completion of installation, the equipment and the venting system shall include: owner shall have a period of thirty(30)days to comply with 3. Detailed instructions for the installation of the venting system the above requirements; provided, however, that during design or the venting system components; and said thirty (30) day period, a battery operated carbon 4. A complete parts list for the venting system design orventing monoxide detector with an alarm shall be installed. system. 2. APPROVED CARBON MONOXIDE DETECTORS. Each (d) MANUFACTURER REQUIREMENTS-GAS EQUIPMENT carbon monoxide detector as required in accordance with VENTING SYSTEM NOT PROVIDED. When the the above provisions shall comply with NFPA 720 and be manufacturer of a Product Approved side wall horizontally ANSI/UL 2034 listed and AS certified. vented gas fueled equipment does not provide the parts 3. SIGNAGE. A metal or plastic identification plate shall be for venting the flue gases, but identifies "special venting permanently mounted to the exterior of the building at a systems",the following requirements shall be satisfied by minimum height of eight(8)feet above grade directly in line the manufacturer: with the exhaust vent terminal for the horizontally vented 5. The referenced "special venting system" instructions shall gas fueled heating appliance or equipment. The sign shall be included with the appliance or equipment installation read, in print size no less than one-half(1/2) inch in size, instructions; and "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS". 6. The"special venting systems"shall be Product Approved by the Board,and the instructions for that system shall include 4. INSPECTION. The state or local gas inspector of the a parts list and detailed installation instructions. side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the (e) A copy of all installation instructions for all Product inspector observes carbon monoxide detectors and signage Approved side wall horizontally vented gas fueled stalled n accordance with the provisions of 248 CMR equipment,all venting instructions,all parts lists for venting in i 5 stalled through 4. instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion EXEMPTIONS of the installation. The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 1. The equipment listed in Chapter 10 entitled"Equipment Not Required To Be Vented"in the most current edition of NFPA 54 as adopted by the Board; and 47 Furnace Model Number Serial Number ELECTRICAL Line Voltage(Measure L1to N and N to Ground Voltage) L-N N-G Secondary Voltage(Measure Transformer Output Voltage) R-C BlowerAmps BLOWER EXTERNAL STATIC PRESSURE Return Air Static Pressure IN.W.C. Supply Air Static Pressure IN.W.C. Total External Static Pressure(Ignoring+/-from the reading above,add total here) IN.W.C. TEMPERATURES Return Air Temperature(Dry bulb/Wet bulb) DB°F WB°F Cooling Supply Air Temperature(Drybulb/Wetbulb) DB°F WB°F Heating Supply Air Temperature DB°F Temperature Rise DB°F Delta T(Difference between Supply and Return Temperatures) DB°F GAS PRESSURES Gas Inlet Pressure IN.W.C. Gas Manifold Pressure(Low Fire) IN.W.C. Gas Manifold Pressure(High Fire) IN.W.C. Gas Type(NG)=Natural Gas/(LP)=Liquid Propane Additional Checks Check wire routings for any rubbing Check for kinked pressure switch tubing. Check flue elbow for alignment and clamp tightness. Check screw tightness on blower wheel. Check factory wiring and wire connections. Check product for proper clearances as noted by installtion instructions °F to°C formula:(°F-32)divided by 1.8=°C °C to°F formula:(°C multiplied by 1.8)+32=°F 48 THIS PAGE IS LEFT INTENTIONALLY BLANK. 49 THIS PAGE IS LEFT INTENTIONALLY BLANK. 50 THIS PAGE IS LEFT INTENTIONALLY BLANK. 51 CUSTOMER FEEDBACK �. We are very interested in all product comments. ER Please fill out the feedback form on one of the following links: ti Goodman'Brand Products:(http://www.goodmanmfg.com/about/contact-us). kJA i L 'r Amana®Brand Products:(http://www.amana-hac.com/about-us/contact-us). You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page. GOODMAN@ BRAND AMANA®BRAND PRODUCT REGISTRATION ■ ■ ■ ■ Thank you for your recent purchase.Though not required to get the protection of Jr- the standard warranty, registering your product is a relatively short process, and entitles you to additional warranty protection, except that failure by California and Quebec residents to register their product does not diminish their warranty rights. For Product Registration,please register as follows: Goodman'Brand products:(https://www.goodmanmfg.com/product-registration). GOODMAN®BRAND AMANA®BRAND Amana®Brand products:(http://www.amana-hac.com/product-registration). You can also scan the QR code on the right for the product brand you purchased to be directed to the Product Registration page. 19001 Kermier Rd. Waller, Tx 77484 www.goodmanmfg.com-www.amana-hac.com ©2021 Goodman Manufacturing Company, L.P. Amana is a registered trademark of Maytag Corporation or its related companies and is used under license.All rights reserved. 52 CONDENSING UNIT ©2023 Daikin Comfort Technologies Manufacturing, L.P. HEAT PUMP 19001 Kermier Rd. Waller, TX 77484 INSTALLATION & SERVICE REFERENCE www.goodmanmfg.com P/N: IOG-4047 Date: December 2023 Important Safety Instructions The following symbols and labels are used throughout this A WARNING manual to indicate immediate or potential safety hazards. It is DO NOT BYPASS SAFETY DEVICES the owner's and installer's responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases A CAUTION the risk of personal injury, property damage, and/or product damage. SCROLL EQUIPPED UNITS SHOULD NEVER BE USED TO EVACUATE THE AIR CONDITIONING SYSTEM.VACUUMS THIS LOW CAN CAUSE WARNING INTERNAL ELECTRICAL ARCING RESULTING IN A DAMAGED OR FAILED COMPRESSOR. HIGH VOLTAGE WARNING DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT.MULTIPLE POWER SOURCES DO NOT USE MEANS TO ACCELERATE THE DEFROSTING MAY BE PRESENT.FAILURE TO DO SO MAY CAUSE PROCESS OR TO CLEAN,OTHER THAN THOSE PROPERTY DAMAGE,PERSONAL INJURY OR DEATH. RECOMMENDED BY THE MANUFACTURER. THE APPLIANCE SHALL BE STORED IN A ROOM WITHOUT WARNING CONTINUOUSLY OPERATING IGNITION SOURCES(FOR EXAMPLE: OPEN FLAMES,AN OPERATING GAS APPLIANCE OR AN OPERATING ELECTRIC HEATER. ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL, ADJUST,SERVICE, MAINTENANCE OR REPAIR DO NOT PIERCE OR BURN. (HEREINAFTER,"SERVICE")THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT. BE AWARE THAT REFRIGERANTS MAY NOT CONTAIN AN ODOR. THIS EQUIPMENT IS NOT INTENDED FOR USE BY PERSONS(INCLUDING CHILDREN)WITH REDUCED PHYSICAL,SENSORY OR MENTAL CAPABILITIES,OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE EQUIPMENT. THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SUPERVISION,SERVICE OR SERVICE PROCEDURES. IF YOU SERVICE THIS UNIT,YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. IN ADDITION, IN JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES TO SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL,ONLY LICENSED PERSONNEL SHOULD SERVICE THE EQUIPMENT. IMPROPER SUPERVISION, INSTALLATION, ADJUSTMENT,SERVICING, MAINTENANCE OR REPAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL,OR ATTEMPTING TO INSTALL,ADJUST,SERVICE OR REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER SUPERVISION OR TRAINING MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ■ Aana is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved. �.. Note: This appliance is suitable for outdoor use. and accessories are correct prior to installation. The distrib- utor or manufacturer will not accept claims from dealers for transportation damage or installation of incorrectly shipped Installation Clearances units. Special consideration must be given to location of the con- Overcurrent Protection densing unit(s) in regard to structures, obstructions, other units,and any/all other factors that may interfere with air circu- The following overcurrent protection devices are approved lation. Where possible,the top of the unit should be completely for use. unobstructed;however,if vertical conditions require placement Time delay fuses beneath an obstruction there should be a minimum of 60 HACR type circuit breakers inches between the top of the unit and the obstruction(s). Ensure there is not a potential for refrigerant to pool should a These devices have sufficient time delay to permit the leak occur in the unit.The specified dimensions meet require- motor-compressor to start and accelerate its load. ments for air circulation only.Consult all appropriate regulatory Ensure wiring for the unit is in accordance with national wiring codes prior to determining final clearances. regulations. Another important consideration in selecting a location for the unit(s) is the angle to obstructions. Either side adjacent the valves can be placed toward the structure provided the side Charging Instructions away from the structure maintains minimum service clearance. Corner installations are strongly discouraged. Additional refrigerant above the amount charged in the factory must be added during installation based on lineset length and the compatible indoor model. Carefully follow the Charge Verification section of this manual to ensure proper system function. NOT i OKI RECOMMENDED B j L/77/ B B B A—� A AA— � C C / OK! AA -% AA - AA OK!' q AA � �—AA _�f1 Minimum Airflow Clearance Model Type A B C AA Residential 101, 101, 181, 20" Light Commercial 12" 1 12" 18" 24" This unit can be located at ground floor level or on flat roofs.At ground floor level,the unit must be on a solid, level foundation that will not shift or settle. To reduce the possibility of sound transmission, the foundation slab should not be in contact with or be an integral part of the building foundation. Ensure the foundation is sufficient to support the unit.A concrete slab raised above ground level provides a suitable base. Shipping Inspection Always keep the unit upright; laying the unit on its side or top may cause equipment damage. Shipping damage, and sub- sequent investigation is the responsibility of the carrier. Verify the model number, specifications, electrical characteristics, 2 Wiring Diagrams TYPICAL H/P SEE NOTE#4 HEAT PUMP ROOM THERMOSTAT © © 00 R � 0 © ® 0 #18 GA.7WIRE B W O Y R #18 GA. AIR HANDLER L H R E E 5 WIRE U I A L D E T N L YL BR C E G O E W 7t, RD RD R YL BL WH BR W1 OR SEE WH NOTE W2 #3 BL IL WH e Y1 YL Y2 BL Y u, O L O F o O OR (OPTIONAL) TB Z O OUTDOOR THERMOSTAT w F- CLOSE ON TEMPERATURE FALL F W w #18 GA.6 WIRE NEEDED WHEN OT IS USED. y J 0 K LL ° o HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW (9z � � Z w U W Z > W � TYPICAL H/P SEE NOTE#4 y w z HEAT PUMP ROOM THERMOSTAT } z © 0 0 R 0 © © ® E #18 GA.7 WIRE Wa wa B W O Y R #18 GA. AIR HANDLER pp W y,j L H R E E 5 WIRE w ? E T N L D YL OR GR BR C p O a E G O aye E W RD-, RD R W Qa � w WH GR Oa SEE G 0 w w a O YL BL #OTE W1 > zaa WH y ? ? OR WH 2 WH W2 2 L) WH EHR 3 4 RD NOTE e SEE Y1 #2 (' OR Y2 Z BL BL O Z �0 YL OR OT-1 OR TB Q SEE �� BR �j NOTE OT-2 > #1 (OPTIONAL) #18 GA.7 WIRE NEEDED WHEN TWO OTS ARE USED. OUTDOOR THERMOSTATS CLOSE ON TEMPERATURE FALL HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE NOTES: NOMENCLATURE: COLOR CODES 1) OUTDOOR THERMOSTAT(OT-1)SHOULD BE OT-OUTDOOR THERMOSTAT(OPTIONAL) RD-RED THE FIRST TO CLOSE AND THE LAST TO OPEN. EHR-EMERGENCY HEAT RELAY(OPTIONAL) YL-YELLOW 2) JUMPER W1 AND W2 TOGETHER IF OT-2 IS NOT USED. BL-BLUE 3) REMOVE WIRE WHEN USING OUTDOOR THERMOSTAT. BR-BROWN 4) E TERMINAL MAY NOT BE APPLICABLE FOR SOME OR-ORANGE THERMOSTATS. WH-WHITE Wiring is subject to change.Always refer to the wiring diagram on the unit for the most up-to-date wiring. 3 Storage and Transportation unit bases have cutouts under the outdoor coil that permit Units come factory charged with refrigerant. Take care to drainage of frost accumulation. Situate the unit to permit free store unit in a location that will minimize potential for damage. unobstructed drainage of the defrost water and ice. The unit should be stored away from continuously operating In more severe weather locations, it is recommended that sources off ignition. If transporting the unit, ensure relevant the unit be elevated to allow unobstructed drainage and air regulations of the geographic area are followed. flow. The following elevation minimums are recommended: Codes & Regulations Design Temperature Suggested Minimum Elevation above 2 1/2" and ab This product is designed and manufactured to comply with _+15° to ab 8" national codes. Installation in accordance with such codes and/or prevailing local codes/regulations is the responsibility below-5° 12" of the installer. The manufacturer assumes no responsibility Safe Refrigerant Handling for equipment installed in violation of any codes or regulations. Rated performance is achieved after 20 hours of operation. While these items will not cover every conceivable situa- Rated performance is delivered at the specified airflow. See tion, they should serve as a useful guide. outdoor unit specification sheet for split system models or product specification sheet for packaged and light com- WARNING mercial models. Specification sheets can be found at www. g_oodmanmf_q com for Goodman® brand products or www. TO AVOID POSSIBLE INJURY,EXPLOSION OR DEATH,PRACTICE SAFE amana-hac.com for AmanaO brand products. Within either HANDLING OF REFRIGERANTS. website, please select the residential or commercial products menu and then select the submenu for the type of product WARNING to be installed, such as air conditioners or heat pumps, to access a list of product pages that each contain links to that REFRIGERANTS ARE HEAVIER THAN AIR.THEY CAN"PUSH OUT"THE model's specification sheet. OXYGEN IN YOUR LUNGS OR IN ANY ENCLOSED SPACE.TO AVOID POSSIBLE DIFFICULTY IN BREATHING OR DEATH: The United States Environmental Protection Agency NEVER PURGE REFRIGERANT INTO AN ENCLOSED ROOM OR (EPA) has issued various regulations regarding the in- SPACE.BY LAW,ALL REFRIGERANTS MUST BE RECLAIMED. troduction and disposal of refrigerants. Failure to follow IF AN INDOOR LEAK IS SUSPECTED,THOROUGHLY VENTILATE THE AREA BEFORE BEGINNING WORK. these regulations may harm the environment and can LIQUID REFRIGERANT CAN BE VERY COLD.TO AVOID POSSIBLE lead to the imposition of substantial fines. Should you FROSTBITE OR BLINDNESS,AVOID CONTACT AND WEAR GLOVES have any questions please contact the local office of the EPA. AND GOGGLES.IF LIQUID REFRIGERANT DOES CONTACT YOUR SKIN OR EYES,SEEK MEDICAL HELP IMMEDIATELY. If replacing a condensing unit or air handler,the system must ALWAYS FOLLOW EPA REGULATIONS.NEVER BURN REFRIGERANT, be manufacturer approved and Air Conditioning, Heating and AS POISONOUS GAS WILL BE PRODUCED. Refrigeration Institute(AHRI)matched. NOTE: Installation of unmatched systems is not allowed. A WARNING Outdoor units are approved for operation above 55°F in TO AVOID POSSIBLE EXPLOSION: cooling mode. Operation below 55°F requires the use of an NEVER APPLY FLAME OR STEAM TO A REFRIGERANT CYLINDER.IF approved low ambient kit. NOTE: LAKT01 Low ambient kit YOU MUST HEAT A CYLINDER FOR FASTER CHARGING, PARTIALLY cannot be used with outdoor units containing ECM motors. IMMERSE IT IN WARM WATER. NEVER FILL A CYLINDER MORE THAN 80%FULL OF LIQUID Damage to the unit caused by operating the unit in a structure REFRIGERANT. that is not complete (either as part of new construction or NEVER ADD ANYTHING OTHER THAN R-32 TO AN R-32 CYLINDER. renovation) Is not covered by the warranty. THE SERVICE EQUIPMENT USED MUST BE LISTED OR CERTIFIED FOR THE TYPE OF REFRIGERANT USED. STORE CYLINDERS IN A COOL,DRY PLACE.NEVER USE A CYLINDER AS A PLATFORM OR A ROLLER. Rooftop Installations If it is necessary to install this unit on a roof structure, ensure the roof structure can support the weight and that proper A WARNING consideration is given to the weather-tight integrity of the roof. Since the unit can vibrate during operation, sound vibration TO AVOID POSSIBLE EXPLOSION,USE ONLY RETURNABLE(NOT DISPOSABLE)SERVICE CYLINDERS WHEN REMOVING REFRIGERANT transmission should be considered when installing the unit. FROM A SYSTEM. Vibration absorbing pads or springs can be installed between ENSURE THE CYLINDER IS FREE OF DAMAGE WHICH COULD LEAD the condensing unit legs or frame and the roof mounting TO A LEAK OR EXPLOSION. assembly to reduce noise vibration. • ENSURE THE HYDROSTATIC TEST DATE DOES NOT EXCEED 5 YEARS. NOTE: These units require special location consideration ENSURE THE PRESSURE RATING MEETS OR EXCEEDS 400 LBS. in areas of heavy snow accumulation and/or areas with WHEN IN DOUBT,DO NOT USE CYLINDER. prolonged continuous subfreezing temperatures. Heat pump Prior to beginning work on systems containing flammable 4 refrigerants, safety checks are necessary to ensure that the A risk of ignition is minimized.Work shall be undertaken under WARNING controlled procedure as stated in this manual so as to minimize the risk of a flammable gas or vapor being present while the PARTIAL UNITS SHALL ONLY BE CONNECTED TO AN APPLIANCE work is being performed.All persons working in the local area I SUITABLE FOR THE SAME REFRIGERANT. shall be instructed on the nature of work being carried out. Review serial plate on both evaporator and condenser unit Work in confined spaces shall be avoided. The area shall be to assure the maximum operating pressure matches before checked with an appropriate refrigerant detector prior to and connecting. during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equip- Use only refrigerant grade (dehydrated and sealed) copper ment being used is suitable for use with A2L refrigerants, i.e. tubing to connect the condensing unit with the indoor evapora- non-sparking, adequately sealed or intrinsically safe. tor. Use the minimum amount of copper tubing where possible. After cutting the tubing, install plugs to keep refrigerant tubing If any hot work is to be conducted on the refrigerating equip- clean and dry prior to and during installation. Tubing should ment or any associated parts, appropriate fire extinguishing always be cut square keeping ends round and free from burrs. equipment shall be available. Have a dry powder or CO2 fire Clean the tubing to prevent contamination. extinguisher adjacent to the charging area.No person carrying out work on the refrigeration system shall use any sources This unit is a partial unit air conditioner and must only be of ignition in such a manner that it may lead to the risk of fire connected to other units that have been confirmed to comply or explosion.All possible ignition sources, including cigarette with corresponding partial unit requirements. smoking, should be kept sufficiently far from the site of work, To prevent physical damage to refrigerant lines during oper- during which refrigerant can possibly be released to the sur- ation and service, do NOT let refrigerant lines come in direct rounding space. Prior to work taking place, the area around contact with plumbing,ductwork,floorjoists,wall studs,floors, the equipment is to be surveyed to make sure that there are and walls. When running refrigerant lines through a founda- no flammable hazards or ignition risks. "No Smoking" signs tion or wall, openings should allow for sound and vibration shall be displayed. absorbing material to be placed or installed between tubing Ensure that the area is in the open or that it is adequately and foundation. Any gap between foundation or wall and ventilated before breaking into the system or conducting refrigerant lines should be filled with a pliable silicon-based any hot work. A degree of ventilation shall continue during caulk, RTV or a vibration damping material.Avoid suspending the period that the work is carried out. Ventilation should be refrigerant tubing from joists and studs with rigid wire or straps provided such that any leaked refrigerant will safely disperse, that would come in contact with the tubing. Use an insulated or preferably expelled externally into the atmosphere.The outlet suspension type hanger.Ensure installation of refrigerant lines for the vacuum pump shall not be close to any potential ignition is in compliance with nation and local codes and standards. sources and ventilation shall be available. Compliance with national gas regulations shall be observed. Take care to avoid contamination of different refrigerants Keep both lines separate and always insulate the suction line. when using charging equipment. Hoses or lines should be All field joints created shall be accessible for inspection prior as short as possible.The refrigerant cylinders should be kept to being covered or enclosed.When installing refrigerant lines in an appropriate position according to their instructions. If a between evaporating and condensing unit, ensure there are refrigerant leak is suspected, all naked flames shall be ex- no connecting joints and no bends with a centerline radius tinguished and the area shall be ventilated. If a leak is found less than 2.5 times the external pipe diameter. which requires brazing,all refrigerant shall be recovered from These sizes are recommended for line lengths of 79 feet or the system prior to performing hot work. less to obtain optimum performance. For alternate line sizing If a refrigerant leak is suspected, all naked flames shall be options or runs of more than 79 feet, refer to TP-110 Long Line extinguished and the area shall be ventilated. If a leak is found SetApplication R-32,or contact your distributorfor assistance. which requires brazing,all refrigerant shall be recovered from the system prior to performing hot work. Ensure the unit is earthed prior to charging the system. RECOMMENDED INTERCONNECTING TUBING(Ft) Cond 0-24 1 25-49 1 50-79' Unit Line Diameter(In. OD) Refrigerant Lines Tons Suct Liq Suct Liq Suct Liq 1 1/2 5/8 1/4 3/4 3/8 3/4 3/8 CAUTION 2 5/8 1/4 3/4 3/8 3/4 3/8 2 1/2 5/8 1/4 3/4 3/8 3/4 3/8 THE COMPRESSOR OIL FOR R-32 UNITS IS EXTREMELY SUSCEPTIBLE 3 3/4 3/8 7/8 3/8 7/8 3/8 TO MOISTURE ABSORPTION AND COULD CAUSE COMPRESSOR FAILURE. 3 1/2 7/8 1 3/8 1 1 1/8 1 3/8 1 1 1/8 1 3/8 DO NOT LEAVE SYSTEM OPEN TO ATMOSPHERE ANY LONGER THAN 4 7/8 3/8 1 1/8 3/8 1 1/8 3/8 NECESSARY FOR INSTALLATION. 5 7/8 3/8 1 1 1/8 3/8 1 1/8 3/8 `Lines greater than 79 feet in length or vertical elevation from more than 50 feet refer to the TP-110 R-32 Long Line Set Application Guide lines or contact your distributor for assistance. 5 Liquid Line QO o Refrigerant Line Connections Suction Line IMPORTANT ® To avoid overheating the service valve, TXV valve, or filter drier while brazing, wrap the component with a Mounting the evaporator coil above the wet rag, or use a thermal heat trap compound. Be sure condensing unit will require an inverted loop in the suction line adjacent or near to follow the manufacturer's instruction when using the - the connection to the evaporator.The top heat trap compound. NOTE: Remove Schrader valves 0 of the loop must be slightly higher than the from service valves before brazing tubes to the valves. top of the coil o Use a brazing alloy of 2/o minimum silver content. Do not use flux. Mounting the condensing unit above the Before conducting any hot work,ensure the area is in the evaporator coil will not require an oil trap open or has adequate ventilation. The ventilation shall in the suction line at the evaporator, continue during the period of hot work and should safely except when the condensing unit disperse any released refrigerant.Torch heat required to is over 80 feet above the evaporator. 0 braze tubes of various sizes is proportional to the size of Refer to the latest revision of the tube.Tubes of smaller size require less heat to bring iong line set guidelines TP-107. the tube to brazing temperature before adding brazing alloy.Applying too much heat to any tube can melt the tube. Service personnel must use the appropriate heat �� level for the size of the tube being brazed. NOTE: The use of a heat shield when brazing is recommended to avoid burning the serial plate or the finish on the unit. Insulation is necessary to prevent condensation from forming 1. The ends of the refrigerant lines must be cut square, and dropping from the suction line. Armflex (or satisfactory deburred, cleaned, and be round and free from nicks equivalent)with 3/8" min.wall thickness is recommended. In or dents.Any other condition increases the chance of a severe conditions (hot, high humidity areas) 1/2" insulation refrigerant leak. may be required. Insulation must be installed in a manner which protects tubing from damage and contamination. 2. "Sweep" the refrigerant line with nitrogen or inert gas during brazing to prevent the formation of copper-oxide Existing Line Sets inside the refrigerant lines. The oils used in R-32 ap- Where possible, drain as much residual compressor oil from plications will clean any copper-oxide present from the existing systems, lines, and traps; pay close attention to low inside of the refrigerant lines and spread it throughout areas where oil may collect. Use of an approved flushing the system.This may cause a blockage or failure of the agent is recommended followed by a nitrogen purge to remove metering device. any remaining flushing agent from the lines or indoor coil. 3. After brazing,quench the joints with water or a wet cloth Replacement of indoor coil is recommended. to prevent overheating of the service valve. NOTE: If using existing indoor coil and changing refrigerant types, ensure the indoor coil and metering device are com- 4. Ensure the filter drier paint finish is intact after brazing. patible with the type of refrigerant being used. If new indoor If the paint of the steel filter drier has been burned or coil is required check spec sheet orAHRI for approved coil. chipped, repaint or treat with a rust preventative. This is especially important on suction line filter driers which Refer to the indoor coil installation manual for instructions are continually wet when the unit is operating. and requirements regarding the installation of the refrigerant detection system to the existing furnace assembly. If system NOTE: Be careful not to kink or dent refrigerant lines. Kinked is being replaced due to compressor electrical failure,assume or dented lines will cause poor performance or compressor acid is in system. Refer to Service Procedure S-115 Com- damage. pressor Burnout in service manual for clean-up procedure. Ensure connections created during installation are accessible Burying Refrigerant Lines for maintenance purposes. If burying refrigerant lines can not be avoided, use the fol- Do NOT make final refrigerant line connection until plugs are lowing checklist. removed from refrigerant tubing. 1. Insulate liquid and suction lines separately. STANDING PRESSURE TEST (RECOMMENDED BEFORE 2. Enclose all underground portions of the refrigerant lines SYSTEM EVACUATION in waterproof material(conduit or pipe)sealing the ends A WARNING where tubing enters/exits the enclosure. 3. If the lines must pass under or through a concrete slab, TO AVOID THE RISK OF FIRE OR EXPLOSION,NEVER USE OXYGEN, ensure lines are adequately protected and sealed. HIGH PRESSURE AIR OR FLAMMABLE GASES FOR LEAK TESTING OF A REFRIGERATION SYSTEM. 6 NOTE: SCROLL COMPRESSORS SHOULD NEVER BE USED WARNING TO EVACUATE OR PUMP DOWN A HEAT PUMP OR AIR CONDITIONING SYSTEM. TO AVOID POSSIBLE EXPLOSION,THE LINE FROM THE NITROGEN CYLINDER MUST INCLUDE A PRESSURE REGULATOR AND A PRESSURE CAUTION RELIEF VALVE.THE PRESSURE RELIEF VALVE MUST BE SET TO OPEN AT A NO MORE THAN 450 PSIG. PROLONGED OPERATION AT SUCTION PRESSURES LESS THAN 20 PSIG FOR MORE THAN 5 SECONDS WILL RESULT IN OVERHEATING OF THE SCROLLS AND PERMANENT DAMAGE TO THE SCROLL TIPS, DRIVE Using dry nitrogen, pressurize the system to 450 PSIG.Allow BEARINGS AND INTERNAL SEAL. the pressure to stabilize and hold for 15 minutes (minimum). If the pressure does not drop below 450 PSIG the system is DEEP VACUUM METHOD (RECOMMENDED) considered leak free. Proceed to system evacuation using The Deep Vacuum Method requires a vacuum pump rated for the Deep Vacuum Method. If after 15 minutes the pressure 500 microns or less.This method is an effective and efficient drops below 450 PSIG follow the procedure outlined below way of assuring the system is free of non-condensable to identify system leaks. Repeat the Standing Pressure Test. air and moisture. As an alternative, the Triple Evacuation Method is detailed in the Service Manual for this product LEAK TESTING NITROGEN OR NITROGEN-TRACED model. AWARNING It is recommended to remove the Schrader Cores from the service valves using a core-removal tool to expedite the TO AVOID THE RISK OF FIRE OR EXPLOSION,NEVER USE OXYGEN, evacuation procedure. HIGH PRESSURE AIR OR FLAMMABLE GASES FOR LEAK TESTING OF A REFRIGERATION SYSTEM. 1. Connect the vacuum pump, micron gauge,and vacuum rated hoses to both service valves. Evacuation must use both service valves to eliminate system mechanical AWARNING seals. 2. Evacuate the system to less than 500 microns. TO AVOID POSSIBLE EXPLOSION,THE LINE FROM THE NITROGEN CYLINDER MUST INCLUDE A PRESSURE REGULATOR AND A PRESSURE 3. Isolate the pump from the system and hold vacuum RELIEF VALVE.THE PRESSURE RELIEF VALVE MUST BE SET TO OPEN AT for 10 minutes (minimum). Typically, pressure will rise NO MORE THAN 450 PSIG. slowly during this period. If the pressure rises to less than 1000 microns and remains steady, the system is Leak test the system using dry nitrogen and soapy water considered leak-free; proceed to system charging and to identify leaks. If you prefer to use an electronic leak startup. detector, charge the system to 10 PSIG with the appropriate 4. If pressure rises above 1000 microns but holds steady system refrigerant (see Serial Data Plate for refrigerant below 2000 microns, non-condensable air or moisture identification). Ensure the leak tester sensitivity is at least may remain or a small leak is present. Return to step 5 grams per year or better. For R32, the detector may need 2: If the same result is achieved check for leaks and to be re-calibrated. It should be calibrated to the percentage repair. Repeat the evacuation procedure. corresponding to 25% of the LFL(Lower flammability limit) of R-32. Do not use an alternative refrigerant. Using dry 5. If pressure rises above 2000 microns, a leak is pres- nitrogen finish charging the system to 450 PSIG. Apply ent. Check for leaks and repair. Repeat the evacuation the leak detector to all suspect areas. When leaks are procedure. discovered, repair the leaks, and repeat the pressure test. If leaks have been eliminated proceed to system evacuation. Detectors that could be considered potential sources of 5000 ignition shall not be used. 4500 SYSTEM EVACUATION Z 4000 Condensing unit liquid and suction valves are closed to 3500 LEAK(S) contain the charge within the unit. The unit is shipped with PRESENT the valve stems closed and caps installed. Do not open 3000 valves until the system is evacuated. 2500 U j 2000 A WARNING 1500 CONDENSIBLES OR SMALL LEAK PRESENT REFRIGERANT UNDER PRESSURE! 1000 FAILURE TO FOLLOW PROPER PROCEDURES MAY CAUSE PROPERTY 500 NO LEAKS DAMAGE, PERSONAL INJURY OR DEATH. NO CONDENSIBLES 0 1 2 3 4 5 6 7 8 9 10 MINUTES 7 Electrical Connections High Voltage Connections Route power supply and ground wires through the high volt- WARNING age port and terminate in accordance with the wiring diagram provided inside the control panel cover. HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING.MULTIPLE POWER SOURCES MAY BE PRESENT. LOW Voltage Connections FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, Cooling only units require 25VA minimum and heat pump units PERSONAL INJURY OR DEATH DUE TO ELECTRIC SHOCK.WIRING MUST CONFORM WITH NEC OR CEC require 40VA minimum. Low voltage wiring for two-stage units AND ALL LOCAL CODES.UNDERSIZED WIRES COULD depends on the thermostat used and the number of control CAUSE POOR EQUIPMENT PERFORMANCE,EQUIPMENT wires between the indoor unit and the condensing unit. Route DAMAGE OR FIRE. control wires through the low voltage port and terminate In accordance with the wiring diagram provided inside the control AWARNING panel cover. System Start Up To AVOID THE RISK OF FIRE OR EQUIPMENT DAMAGE,USE COPPER CONDUCTORS. WARNING NOTICE HIGH VOLTAGE! UNITS WITH ROTARY OR RECIPROCATING COMPRESSORS AND NON- DISCONNECT ALL POWER BEFORE SERVICING OR BLEED TXV'S REQUIRE A HARD START KIT. INSTALLING THIS UNIT.MULTIPLE POWER SOURCES MAY BE PRESENT. Irk The condensing unit rating plate lists pertinent electrical data FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, necessary for proper electrical service and overcurrent protec- PERSONAL INJURY OR DEATH. V , tion.Wires should be sized to limit voltage drop to 2% (max.) NOTE: Units with crankcase heaters should have high from the main breaker or fuse panel to the condensing unit. voltage power energized for 24 hours prior to start up. Consult the NEC, CEC, and all local codes to determine the correct wire gauge and length. Ensure wiring for the unit is in Heat Pumps are equipped with a time/temperature defrost accordance to national wiring regulations. Check that wiring control with field selectable defrost intervals of 30, 60, 90 will not be subject to wear, corrosion, excessive pressure, minutes. In Region IV,the defrost control should be set to vibration, sharp edges or any other adverse environmental an interval according to the table below.This setting should effects. Ensure wiring will not be subject to any of the above be adjusted at this time if needed. The defrost control also effects as a result of aging or continual vibration. has SmartShift (TM) Technology, which delays compressor Local codes often require a disconnect switch located near operation at defrost initiation and termination. If disabling this the unit; do not install the switch on the unit. Refer to the function is desired, move the jumper from "IDLY" to "NORM" installation instructions supplied with the indoor furnace/air on the defrost control. handler for specific wiring connections and indoor unit con- Tonnage Defrost control setting (min) figuration. Likewise, consult the instructions packaged with 1.5 90 the thermostat for mounting and location information. 2 90 2.5 90 Three Phase Compressor Rotation 3 60 3.5 90 A CAUTION 4 90 5 90 USE CARE WHEN HANDLING SCROLL COMPRESSORS.DOME TEMPERATURE COULD BE HOT. Adequate refrigerant charge for the matching AHRI rated Three phase compressors are power phase dependent and designated tested combination (DTC)evaporator coil and 15 can rotate in either direction. feet of lineset is supplied with the condensing unit. If using evaporator coils other than DTC coil, it may be necessary to Verify proper rotation for three phase compressors by ensur- add or remove refrigerant to attain proper charge. If line set ing the suction pressure drops and discharge pressure rises exceeds 15 feet in length, refrigerant should be added at the when the compressor is energized. NOTE: When operated amount specified in the below table based on suction and in reverse, a three phase scroll compressors is noisier and liquid tube diameters. its current draw substantially reduced compared to marked values. To correct, disconnect power and switch any two leads at the unit contactor and re-observe. 8 Be sure to fill out the refrigerant charge label on the lower Do not introduce liquid refrigerant from the cylinder into access panel of the unit. Using a durable marking instrument, the crankcase of the compressor as this may damage the fill in the factory charge found on the serial plate of the unit compressor. in the first box labeled FACTORY CHARGE. In the next box 1. Break vacuum by fully opening liquid and suction base labeled FIELD CHARGE fill in the amount of charge added valves. to the system. NOTE: The field charge amount may not be 2. Set thermostat to call for cooling. Check indoor and finalized until final adjustment. In the third box labeled TOTAL outdoor fan operation and allow system to stabilize for CHARGE add the two amounts in the boxes above. 20 minutes. NOTE: Charge should always be checked using superheat Charge Verification and subcooling when using TXV equipped indoor coil to verify proper charge. A WARNING Initial Charge Addition Liquid Line Diameter (in. OD) REFRIGERANT UNDER PRESSURE! per Foot (oz) 1/4 3/8 DO NOT OVERCHARGE SYSTEM WITH REFRIGERANT. 5/8 0.23 0.53 DO NOT OPERATE UNIT IN A VACUUM OR AT A NEGATIVE PRESSURE. Suction Line FAILURE TO FOLLOW PROPER PROCEDURES MAY CAUSE PROPERTY 3/4 - 0.55 DAMAGE,PERSONAL INJURY OR DEATH. Diameter (in. 0D) 7/8 - 0.58 1-1/8 - 0.64 A WARNING USE REFRIGERANT CERTIFIED TO AHRI STANDARDS.USED Break vacuum by fully opening liquid service valve.After the REFRIGERANT MAY CAUSE COMPRESSOR DAMAGE.MOST PORTABLE refrigerant charge has bled into the system, open the suction MACHINES CANNOT CLEAN REFRIGERANT TO MEET AHRI STANDARDS. service valve.The service valve cap is the secondary seal for the valve and must be properly tightened to prevent leaks. Make sure cap is clean and apply refrigerant oil to threads and NOTICE sealing surface on inside of cap.Tighten cap finger-tight and then tighten additional 1/6 of a turn (1 wrench flat), or to the VIOLATION OF EPA REGULATIONS MAY RESULT IN FINES OR OTHER following specification, to properly seat the sealing surfaces. PENALTIES. ACAUTION A CAUTION POSSIBLE REFRIGERANT LEAK DAMAGE TO THE UNIT CAUSED BY OPERATING THE COMPRESSOR WITH TO AVOID A POSSIBLE REFRIGERANT LEAK,OPEN THE SERVICE VALVES THE SUCTION VALVE CLOSED IS NOT COVERED BY THE WARRANTY AND UNTIL THE TOP OF THE STEM IS 1/8" FROM THE RETAINER. MAY CAUSE SERIOUS COMPRESSOR DAMAGE. When opening valves with retainers, open each valve only FINAL CHARGE ADJUSTMENT until the top of the stem is 1/8"from the retainer. To avoid loss Airflow and Total Static Pressure for the indoor unit should of refrigerant, DO NOT apply pressure to the retainer. When be verified before attempting to charge system. opening valves without a retainer remove service valve cap and insert a hex wrench into the valve stem and back out the 1. Total static pressure is .5" WC or less. stem by turning the hex wrench counterclockwise. Open the valve until it contacts the rolled lip of the valve body. 2. Airflow is correct for installed unit. NOTE:These are not back-seating valves. It is not necessary 3. Airflow tables are in the installation manual and Spec to force the stem tightly against the rolled lip. Sheet for Indoor Unit. Break vacuum by fully opening liquid service valve.After the 4. Complete charging information are in Service Manual refrigerant charge has bled into the system, open the suction RS6200006. service valve.The service valve cap is the secondary seal for the valve and must be properly tightened to prevent leaks. NOTE: SUPERHEAT ADJUSTMENTS SHOULD NOT BE MADE Make sure cap is clean and apply refrigerant oil to threads and UNTIL INDOOR AMBIENT CONDITIONS HAVE STABILIZED. sealing surface on inside of cap.Tighten cap finger-tight and THIS COULD TAKE UP TO 24 HOURS DEPENDING ON then tighten additional 1/6 of a turn (1 wrench flat), or to the INDOOR TEMPERATURE AND HUMIDITY. BEFORE CHECKING following specification, to properly seat the sealing surfaces. SUPERHEAT RUN THE UNIT IN COOLING FOR 10-15 MINUTES 1. 3/8" valve to 5- 10 in-Ibs OR UNTIL REFRIGERANT PRESSURES STABILIZE. USE THE 2. 5/8" valve to 5- 20 in-Ibs FOLLOWING GUIDELINES AND METHODS TO CHECK UNIT OPERATION AND ENSURE THAT THE REFRIGERANT CHARGE 3. 3/4" valve to 5 - 20 in-Ibs IS WITHIN LIMITS. 4. 7/8" valve to 5- 20 in-Ibs 9 SATURATED SUCTION PRESSURE SATURATED LIQUID PRESSURE TEMPERATURE CHART TEMPERATURE CHART SUCTION SATURATED SUCTION LIQUID SATURATED LIQUID PRESSURE TEMPERATURE OF PRESSURE TEMPERATURE OF PSIG R-32 PSIG R-32 40 -7 200 68 42 -6 210 71 44 -4 220 74 48 -1 230 77 50 1 240 80 52 2 250 82 54 4 260 85 56 5 270 87 58 6 280 90 60 8 290 92 62 9 300 94 64 10 310 97 66 12 320 99 68 13 330 101 70 14 340 103 72 15 350 105 74 17 360 107 76 18 370 109 78 19 380 111 80 20 85 23 390 113 90 25 400 115 95 28 410 117 100 30 420 118 105 33 430 120 110 35 440 122 115 37 450 124 120 40 460 125 125 42 470 127 130 44 480 128 135 46 490 130 140 48 500 132 145 50 525 135 150 52 550 139 155 53 575 143 160 55 600 146 165 57 625 150 170 59 1 650 1 153 NOTE:SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE. 10 The outdoor temperature must be 60°F or higher. Set the a. Ensure the thermometer makes adequate contact room thermostat to COOL, fan switch to AUTO, and set the for the best possible readings. temperature control well below room temperature. b. The temperature read with the thermometer should Superheat on indoor coils with adjustable TXV valves are be higher than the saturated suction temperature. factory set and no adjustment is normally required during startup. Only in unique applications due to refrigerant line 2. Measure the pressure using service gauge manifold con- length, differences in height between the indoor and outdoor nected to the true suction access port. Refer to the chart unit and refrigerant tubing sizes or poor performance should above to obtain saturated temperature corresponding to Superheat setting require adjustment. These adjustments the measured pressure. should only be performed by qualified service personnel. For detailed charge and TXV adjustments refer to the 3. The difference between the recorded suction line appropriate Service Manual. temperature and the saturated suction temperature is the Superheat value. Expansion Valve System 4. TXV-based systems should have a Superheat value Charge by Subcooling:Applicable to Adjustable TXV based on the below table. SUBCOOLING FORMULA = SATURATED LIQUID LINE TEMPERATURE - LIQUID LINE TEMPERATURE Cooling Mode Heating Mode Tonnage Superheat at Subcool at Superheat at Compressor Liquid Valve Compressor 1. Purge the gauge lines and connect the service gauge 1.5 19± 1°F manifold to the liquid(small)service port and true suction 2.0 19± 1°F access port. 2.5 17± 1°F 3.0 16± 1°F 8± 1°F 8± 1°F 2. Clamp a pipe clamp thermometer on the liquid line near 3.5 16± 1°F the liquid line service valve. 4.0 16± 1°F 5.0 16± 1°F a. Ensure the thermometer makes adequate contact to obtain the best possible readings. 5. Adjust Superheat by turning the TXV valve stem clock- b. The temperature read with the thermometer should wise to increase and counterclockwise to decrease. be lower than the saturated condensing temperature. a. If Subcooling and Superheat are low, adjust the 3. Measure pressure using service gauge manifold con- TXV to the superheat value in step 4 and then check nected to the liquid(small)service port. Refer to the chart Subcooling. above to obtain saturated temperature corresponding to b. If Subcooling is low and Superheat is high, add the measured pressure. charge to raise Subcooling to 8°F +/- 1°F then 4. The difference between the saturated condensing tem- check Superheat. perature and the recorded liquid line temperature is the c. If Subcooling and Superheat are high, adjust the liquid Subcooling value. TXV valve to the superheat value in step 4 then 5. TXV-based systems should have a Subcooling value check the Subcooling value. of 8°F +/- 1 OF. d. If Subcooling is high and Superheat is low, adjust 6. Add refrigerant to increase Subcooling and remove the TXV valve to the superheat value in step 4 and refrigerant to decrease Subcooling. remove charge to lower the Subcooling to 8°F+/- Adjust Superheat: 1 OF. NOTE: DO NOT adjust the charge based exclusively on Superheat can also be utilized to best verify charge levels suction pressure unless for general charging in the case of with an adjustable TXV and make adjustments when need- a gross undercharge. ed in unique applications due to refrigerant line length, differences in height between the indoorand outdoor unit NOTE: Check the Schrader ports for leaks and tighten valve and refrigerant tubing sizes. These adjustments should cores if necessary. Install caps finger-tight. only be performed by qualified service personnel. Heat Pump - Heating Cycle The proper method of charging a heat pump in the heat mode Required Superheat is by weight with the additional charge adjustments for line size, line length, and other system components. For best SUPERHEAT FORMULA= SUCTION LINE TEMPERA- TURE -SATURATED SUCTION TEMPERATURE 1. Clamp a pipe clamp thermometer 4-6"from compressor on suction line at the outdoor unit. 11 results, on outdoor units with TXVs, superheat should be 8°F +/- 1°F at 4-6"from the compressor. Make final charge adjustments in the cooling cycle. Ensure the charge label has been filled out when final charging is complete. Follow directions in the System Startup section. A final leak test is recommended before leaving the site of installation. When servicing is complete, the red valve caps that are supplied on the valves must be reinstalled finger-tight on the liquid valve, vapor valve, and access port. NOTE: Maximum refrigerant charge permissible in the system can be found on the Evaporator serial plate. System Service and Decommissioning Should repairs requiring recovery of the refrigerant become necessary, special considerations must be made when breaking into systems with flammable refrigerants. These repairs shall only be performed by qualified service person- nel and in compliance with local and national regulations. The refrigerant charge shall only be recovered into a cyl- inder labeled for use with R-32. Ensure that the refrigerant cylinder(s) are capable of holding the total system charge. Cylinders shall be complete with a pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.A set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. All best practices for refrigerant recovery must be followed, including use of a recovery machine designated safe for use with A2L refrigerants. Isolate the system electrically prior to recovery. Ensure that all personal protective equip- ment is being applied correctly. Ensure that the recovery process is supervised at all times by the qualified servicer. Situate the R-32 cylinder on the scale before recovery takes place. Start the recovery machine and operate in accordance with its instructions. Do not overfill cylinders by more than 80%volume of its allowed liquid charge. Should electrical components need to be replaced, ensure that the original equipment manufacturer's part or equiva- lent is used. Markings and warnings on the unit shall continue to be visible and legible after installation and service. Correct any markings and warnings that are made illegible. When decommissioning a system, all previously mentioned precautions regarding safe refrigerant handling must be fol- lowed.Recovered refrigerant shall not be charged into another refrigerating system unless it has been cleaned and checked. Equipment must be labelled, dated, and signed stating that it has been decommissioned and emptied of refrigerant. 12 Troubleshooting Information System Complaint No Cooling Unsatisfactory Cooling/Heating Operating Pressures rn r � rn E m p C @ C O POSSIBLE CAUSE 2 2N g g t C C @ > ` C ° r r _ w E o a) o Test Method DOTS IN ANALYSIS 11 = N o N o N `c E o GUIDE INDICATE 2 y o 0 o C o' o ° c° Remedy 3 o a "POSSIBLE CAUSE" y N 0 o 3 c 3 3 �, o w L o a 0 3 O w w 2 c N y w a y n d c V C c O m h — = o. c a 3 a N ac 2 — 2 m 3 5v+ Lcoa306 cc E Eo c m E a) a N caa cpNEE Caa NCCOT O O > O O a) O >R . w0 1 to0 1 Power Failure • 1 1 1 1 Test Voltage Blown Fuse • • a. . Inspect Fuse Size&Type Unbalanced Power,3PH • Test Voltage Loose Connection • Inspect Connection-Tighten Shortedr Broken Wires • • • Test Circuits With Ohmmeter Open Fan Overload • • Test Continuity of Overload Faulty Thermostat • • • • Test Continuity of Thermostat&Wiring Faulty Transformer • • Check Control Circuit with Voltmeter Shorted or Open Capacitor • • • ITest CaDacitor Internal Compressor Overload Open • ♦ Test Continuity of Overload Shorted or Grounded Compressor • • Test Motor Windings Compressor Stuck • • • ♦ Use Test Cord F • • • Faulty Fan Relay • Test Continuity of Coil And Contacts Open Control Circuit • Test Control Circuit with Voltmeter Low Voltage • • • Test Voltage Faulty Evar)_Fan Motor • • Shorted or Grounded Fan Motor • • Test Motor Windings Improper Cooling Anticipator • • Check Resistance of Anticipator Shortage of Refrigerant • • ♦ • • Test For Leaks Add Refrigerant Restricted L aumd Lone • • • • • Open Element or Limit on Elec.Heater ♦ ♦ Test Heater Element and Controls Dirty Air Filter • • • • ♦ Inspect Filter-Clean or Replace Dirtv Indoor Coil • • • • Insoect Coil-Clean Not enough air across Indoor Coil • • • • ♦ Check Blower speed,Duct Static Press Filter Too much air across Indoor Coil ♦ • Reduce Blower S eed Overcharge of Refrigerant • • ♦ • • Recover Part of Change OutdoorDirty it • • • • • Insoect Coil-Clean Noncondensibles • • • Recover Charge,Evacuate Recharge Recirculation of Condensing Air • • • Remove Obstruction to Air Flow Infiltration of Outdoor Air • • • Check Windows Doors Vent Fans Etc. Located Thermostat • • IRAInnntp.Thermostat Air Flow Unbalanced • • Read'ust Air Volume Dampers System Undersized • • Refigure Cooling Load Broken Internal Parts • Replace Compressor Broken Valves • • 1 • • Test Compressor Efficiency _i_� Inefficient Compressor IL • 1 6 1 1 • 1 • Test Compress r Efficiency Wrong Type Expansion Valve • • • • • • Replace Valve Expansion Device Restri d • • • • • • • Remove Restriction or Replace Expansion D vi Oversized Expansion Valve • • Replace Valve Undersized Expansion Valve • • • • • Replace Valve Expansion Valve Bulb Loose T • Ti hten Bulb Bracket Ino erative Ex ansion Valve • • • Check Valve O eration Loose Hold-down Bolts Tighten Bolts FaultyReversingValve • Replace Valve or Solenoid Faul Defrost Control • Test Control FaultyDefrost Thermostat Test Defrost Thermostat • Cooling or Heating Cycle(Heat Pump) ♦ Heating Cycle Only(Heat Pump) For detailed service information refer to the Remote Condensing Unit Service manual. NOTICE UNITS WITH ROTARY OR RECIPROCATING COMPRESSORS AND NON-BLEED TXV'S REQUIRE A HARD START KIT. 13 SPLIT SYSTEMS AIR CONDITIONING AND HEAT PUMP HOMEOWNER'S ROUTINE MAINTENANCE RECOMMENDATIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a gualified servicer. Replace or Clean Filter Clean Outside Coil (Qualified Servicer Only) IMPORTANT NOTE: Never operate unit without a filter in- stalled as dust and lint will build up on internal parts resulting A WARNING in loss of efficiency, equipment damage and possible fire. An indoor air filter must be used with your comfort system. HIGH VOLTAGE A properly maintained filter will keep the indoor coil of your DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT.MULTIPLE POWER SOURCES comfort system clean.A dirty coil could cause poor operation MAY BE PRESENT.FAILURE TO DO SO MAY CAUSE and/or severe equipment damage. PROPERTY DAMAGE,PERSONAL INJURY OR DEATH. Your air filter or filters could be located in your furnace, in a blower unit, or in "filter grilles" in your ceiling or walls. The Air must be able to flow through the outdoor unit of your installer of your air conditioner or heat pump can tell you comfort system. Do not construct a fence near the unit or where your filter(s) are, and how to clean or replace them. build a deck or patio over the unit without first discussing your Check your filter(s) at least once a month. When they are plans with your dealer or other qualified servicer. Restricted dirty, replace or clean as required. Disposable type filters airflow could lead to poor operation and/or severe equipment should be replaced. Reusable type filters may be cleaned. damage. You may want to ask your dealer about high efficiency filters. Likewise, it is important to keep the outdoor coil clean. Dirt, High efficiency filters are available in both electronic and leaves, or debris could also restrict the airflow. If cleaning of non-electronic types. These filters can do a better job of the outdoor coil becomes necessary, hire a qualified servicer. catching small airborne particles. Inexperienced people could easily puncture the tubing in the coil. Even a small hole in the tubing could eventually cause Compressor a large loss of refrigerant. Loss of refrigerant can cause poor The compressor motor is hermetically sealed and does not operation and/or severe equipment damage. require additional oiling. Do not use a condensing unit cover to "protect"the outdoor Motors unit during the winter, unless you first discuss it with your dealer. Any cover used must include "breathable" fabric to Indoor and outdoor fan motors are permanently lubricated avoid moisture buildup. and do not require additional oiling. BEFORE CALLING YOUR SERVICER • Check the thermostat to confirm that it is properly set. Check the electrical panel for tripped circuit breakers • Wait 15 minutes. Some devices in the outdoor unit or or failed fuses. Reset the circuit breakers or replace in programmable thermostats will prevent compressor fuses as necessary. operation for a while,and then reset automatically.Also, Check the disconnect switch near the indoor furnace some power companies will install devices which shut or blower to confirm that it is closed. off air conditioners for several minutes on hot days. If Check for obstructions on the outdoor unit . Confirm you wait several minutes,the unit may begin operation that it has not been covered on the sides or the top. on its own. Remove any obstruction that can be safely removed. If the unit is covered with dirt or debris, call a qualified A CAUTION servicer to clean it. TO AVOID THE RISK OF EQUIPMENT DAMAGE OR FIRE,INSTALL THE Check for blockage of the indoor air inlets and outlets. SAME AMPERAGE BREAKER OR FUSE AS YOU ARE REPLACING.IF THE Confirm that they are open and have not been blocked CIRCUIT BREAKER OR FUSE SHOULD OPEN AGAIN WITHIN THIRTY DAYS, by objects (rugs, curtains or furniture). CONTACT A QUALIFIED SERVICER TO CORRECT THE PROBLEM.IF YOU HAVE REPEATEDLY RESET THE BREAKER OR REPLACED THE FUSE Check the filter. If it is dirty, clean or replace it. WITHOUT HAVING THE PROBLEM CORRECTED,YOU RUN THE RISK OF SEVERE EQUIPMENT DAMAGE. Listen for any unusual noise(s), other than normal op- erating noise, that might be coming from the outdoor unit. If you hear unusual noise(s)coming from the unit, call a qualified servicer. 14 Start-Up Checklist Condenser/Heat Pump(including all Inverter) Model Number Serial Number ELECTRICAL(Outdoor Unit) Line Voltage(Measure L1 and L2 Voltage) L1-L2 Secondary Voltage(Measure Transformer Output Voltage)NOT ALL MODELS R-C Compressor Amps Condenser Fan Amps TEMPERATURES(Indoor Unit) Return Air Temperature(Dry bulb/Wet bulb) DB°F WB°F Cooling Supply Air Temperature(Dry bulb/Wet bulb) DB°F WB°F Delta T(Difference between Supply and Return Temperatures) DB°F PRESSURES/TEMPERATURES(Outdoor Unit) Suction Circuit(Pressure/Suction Line Temperature) PSIG TEMP °F Liquid Circuit(Pressure/Liquid Temperature) PSIG TEMP °F Outdoor Air Temperature(Dry bulb/Wet bulb) DB°F WB°F SUPERHEAT/SUBCOOLING SH SC Line set length in Feet Additional Refrigerant Charge Added over Factory Charge(Ounces) Additional Checks Check wire routings for any rubbing Check factory wiring and wire connections. Check product for proper clearances as noted by installation instructions 'F to'C formula:('F-32)divided by 1.8="C 'C to"F formula:('C multiplied by 1.8)+32="F 15 CUSTOMER FEEDBACK 19 �: � We are very interested in all product comments. %. ' Please fill out the feedback form on one of the following links: FIF `Goodman®Brand Products: (http://www.goodmanmfg.com/about/contact-us). Fi '�Amana°Brand Products: (http://www.amana-hac.com/about-us/contact-us). You can also scan the QR code on the right for the product brand ❑% .' you purchased to be directed to the feedback page. GOODMAN@ BRAND AMANA°BRAND PRODUCT REGISTRATION Thank you for your recent purchase.Though not required to get the protection of I@ i_ the standard warranty, registering your product is a relatively short process, and entitles you to additional warranty protection, except that failure by California and •' :01 . Quebec residents to register their product does not diminish their warranty rights. The duration of warranty coverages in Texas and Florida differs in some cases. For Product Registration, please register as follows: GOODMAN@ BRAND AMANA°BRAND Goodman°Brand products: (https://www.goodmanmfg.com/product-registration). Amana°Brand products: (http://www.amana-hac.com/product-registration). You can also scan the QR code on the right for the product brand you purchased to be directed to the Product Registration page. 19001 Kermier Rd. Waller, TX 77484 www.goodmanmfg.com -or-www.amana-hac.com ©2023 Daikin Comfort Technologies Manufacturing, L.P. JOSsnana is a registered trademark of Maytag Corporation or its related companies and is used under license.All rights reserved. 16 18204 59th Avenue NE • op ' • 14 Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Residential - Mechanical Permit Parcel:00870600001100 Permit#:26-0189 Permit Address:17520 HIGHLAND VIEW DR Date Issued:March 4,2026 Description of Work:LIKE FOR LIKE 80X80 PERMIT EXPIRES 180 DAYS FURNACE CHANGE OUT WITH A/C ADD AFTER DATE OF ISSUANCE. Valuation:$12000 Code Year:2021 OWNER APPLICANT CONTRACTOR BARRON HEATING AND AIR CONDITIONING, RACHEL MICEK Amy Eardley INC. 2629 LAUREL DR CLARKSTON,WA,99403 5100 Pacific Hwy (360)676-1131 360 676 1131 RACHELMICEKDVM@GMAIL.COM permitting@barronheating.com AMYE@BARRONHEATING.COM registration_number:600-092-564 PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved mechanical equipment 2.) Permit shall be onsite for inspecton 3.) Call for inspections INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance March 3, 2026 Mechanical Base Fee(006.322.10.00.01) $25.00 March 3, 2026 Processing/Technology(320.341.43.00.02) $25.00 March 3, 2026 Forced Air Heat(006.322.10.00.01) $15.00 March 3, 2026 Air Cond. Unit(006.322.10.00.01) $15.00 March 3, 2026 Inspection(006.322.10.00.01) $75.00 TOTAL: Permit Fees $155.00 $155.00 Credit/Debit Card 381 Payment Successful March 4, 2026 $155.00 $0.00 PotT �l �t#�n - � aidential Mechanical ?' $50.00 (https-.//www.civicgov4.com/wa arlington/parcels/edit/7698) Residential Mechanical A-1- Edit (https://www.civicgov4.com/wa arlington/permits/edit/317) Print Menu or tJ Site Address: 17520 HIGHLAND VIEW DR (https://www.civicgov4.com/wa_arlington/p rr .3 Project Name: MICEK (https://www.civicgov4.com/wa_arlington/p rr Record #288 of 294 J Project Valuation: 12,000.00 (https://www.civicgov4.com/wa_arlington/perr Preferred Contact: (https://www.civicgov4.com/wa_arlington/perr Owner �4,)IJIVMMiactor Property Structure Contractors Inspections Insurance Contacts P escrippimatz nnriimante elated permits Status LIKE FOR LIKE 80X80 FURNACE CHANGE OUT WITH A/C ADD (�w�,petails .C�CYner l�aore: RACHEL MICEK Action Status Home No.: (334)740-3052 E2##il Ac& RACH ELM ICEKDVM@GMA al Mechanical O Filled Htn Cell No.: � Mailing Address: City: ARLINGTON State: WA Zip: 98223 Contractor Details Clt1blisV • BARRON HEATING &A/C lls permits/edit/317) I Print Menu Vh (360)676-1131 n/ ermits/details/25) l (h *y l AMYE@BARRONHEATING. s/details/316) Record #288 of 294 (hl/�dAv permits/details/318) (h tkin *AdxiqW 5100 PACIFIC HWY 'details/323) Copyright @ 2026 CivicPlus (http://www.civicgovcloud.com)