Loading...
HomeMy WebLinkAbout125 W Haller Ave_BLD5895_2026 i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration 0 Replaced ❑ Gas Piping Type I and Type H Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: O8 W. Haller Avenue Project Valuation: 25,000.00 Lot#: Parcel ID No.: 00461802900100 Preferred Contact: ❑ Owner O Contractor Project Description. Like for Like replacement of existing Heat Pump - Replacing 50ft. of Refrigeration Line. City Project Number: PW-U24.001 — MBR Support Building. Owner Name: City of Arlington Public Works Office No.: 360-703-3506 kshores@arlingtonwa.gov Email Address: Cell No.: Mailin Address: 154 W Cox Street City: Arlington State: WA Zip: 98223 Contractor Name: D.K. Systems, Inc. Office No.: 360-755-1555 Email Address: dulce@dksystemsinc.com Cell No.: Po Box 886 Burlington WA 98233 Mailing Address: City: g State: Zip: L&I Contractor License Number: DKSYSI*982L 1 Expiration Date: 06/21/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/8" ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" Inlet Pressure: Pressure Drop: Specific Gravity: REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No. of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Cond.Unit<_100Btu h x $ 15.00 = $ Air Cond.Unit>100Btu h x $ 25.00 = $ Air Cond.Unit>50OBtu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu/h>3hp x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust/Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC <_100 Btu/h x $ 15.00 = $ Gas Fired AC >100 Btu/h x $ 25.00 = $ Gas Fired AC > 500 Btu h x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping> 5 units (plus <5 units x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit 1 x $ 25.00 = $25.00 Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 = $ mechanical code,not otherwise specified Pkg.Units 5100btu x $ 25.00 = $ Pkg.Units >100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee (all) x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters >100 Btu h x $ 25.00 = $ VAV Boxes (Variable Air Volume,part of air x $ 10.00 = $ conditioning system) Wall Heaters - Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2020 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the El Owner, ❑Applicant, ❑Contractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. D euaiy aleead ev Dwce"e�� DNou=aojec[s coom�°amc,o=oK.syaterea,m<•,crv=Dwce D u I ce Herrera"a,re,a E-°° °"sys'erea'°"are Duke Herrera 03/15/2024 R°aao°Iam[deawn°,°1td,e do°—t ocation:4-11-191'1 location Here Date'.2020-03-15 12:28'.21 Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of 3 Beer gtillagUam�sh Twin Rivers Park SO i 4fh W Co I A * i °r* I (D i I Centennial i Trail Park Ave E Haller Ave ! i J i i I W Burke, Ave E Burke Ave U) - - .. 4.0 M v 70 Q Q ca W Gilman Ave a o � z `° - cv E Gilman Ave c cD ? i g —� Z m m _ City of Arlington - Public Works Project Name: 108 W. Haller Ave — MBR Support Building HVAC • e e D-e. Aw11hM�}+riMl�► _ h Vol _ Acces r ' r, ^l INA � cti rrt' X Clear search results l3� Table of Contents SUBMITTAL DATA: PCA-A42KA7 & PUZ-A42NKA7(-BS) OVERVIEW 2 INDOOR UNIT FEATURES 2 OUTDOOR UNIT FEATURES 2 SPECIFICATIONS: PCA-A42KA7 & PUZ-A42NKA7(-BS) 3 ACCESSORIES: PCA-A42KA7 6 ACCESSORIES: PUZ-A42NKA7(-BS) 7 DIMENSIONS: PCA-A42KA7 & PUZ-A42NKA7 (-BS) 8 FRONT WIND BAFFLE 10 SUBMITTAL 1 DATA: 1 1 P 1 1 / 1 & P 1 / 1 CEILING-SUSPENDED HEAT PUMP SYSTEM Art ELECTRIC Job Name: City of Arlington MBR Support Bldg. - HVAC System Reference: Date: Indoor Unit: Outdoor Unit: PCA-A42KA7 9 PUZ-A42NKA7 �lulllllllllllllllllllllltilll�,. HNN ill adllVllllllllllllll lllllllllllllllllllllll6 'iIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIU' ' '� _ ''�IIIIIIIIIIIIIIIIIIIIIIiIIIIIIIIIIIIIIIP'' '"�I!�IIIIIlIIlllllllliolll��� �I�Ilpllllllllllllllllllllulll�,. Irlllllllll!!llllllllllllllllllllllllllil IIIllilllllllllllllllllll911111111111111111111116 -- 'illlllllllllllllllll':!lILIIIIIIIIIIII IIIIIIIIIIP' ''IIIIIIIIIIIIIIiIIII�IIIIIIIIIIIIIIIIIVI''' -"nallllliiillllllllllu�"" INDOOR UNIT FEATURES • Airflow settings for high and low ceiling applications • Knock-out for outside-air intake • Optional i-see SensorTM for air distribution and energy saving • Auto fan speed mode • Filter status indicator • Easy-to-clean,washable filter • Suspends from ceiling for quick and easy installation • Ideal for larger retail stores,classrooms,and restaurants OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications,such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: • 1 1 1 1 1 / 1 OutdoorIndoor Unit PCA-A42KA7 Model Number PUZ-A42NKA7 Btu/h 42, Maximum Capacity „ 000 Rated Capacity Btu/h 42,000 Minimum Capacity Btu/h 16,000 Maximum Power Input W 4,110 Cooling Rated Power Input W 4,110 Moisture Removal Pints/h 11.70 Sensible Heat Factor 0.69 Power Factor % 95.60 Maximum Capacity Btu/h 48,000 Rated Capacity Btu/h 45,000 Minimum Capacity Btu/h 18,100 Heating at 47°FZ Maximum Power Input W 4,300 Rated Power Input W 3,480 Power Factor % 94.60 Maximum Capacity Btu/h 35,000 Heating at 17°F3 Rated Capacity Btu/h 31,800 Maximum Power Input W 3,200 Rated Power Input W 3,160 SEER 17.60 EER*1 10.20 Efficiency HSPF(IV) 10.20 COP at 47°F2 3.78 COP at 17°F3 2.94 Voltage, Phase, Frequency 208/230V, 1-phase,60 Hz Guaranteed Voltage Range V AC 198—253 Voltage: Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage: Indoor-Outdoor,S2-S3 V DC 24 Voltage: Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 30 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 2.00 Fan Motor Full Load Amperage A 0.97 Fan Motor Output W 160 Airflow Rate,Dry CFM 810-885-955-1025 Indoor Unit Airflow Rate,Wet CFM 740-810-885-955 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 39-41-43-45 Drain Pipe Size In.(mm) 1-1/32(26) Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: • 1 1 1 1 1 / 1 Indoor Unit PCA-A42KA7 Outdoor Unit gJJPkUZ Condensate Lift Mechanism,Max.Distance In.(mm) n/a Heat Exchanger Type Plate fin coil External Finish Color White Munsell 6AY 8.9/0.4 W:In.(mm) 63(1600) Unit Dimensions D: In.(mm) 26-3/4(680) H: In.(mm) 9-1/16(230) W: In. 53-2/16 Package Dimensions D:In. 29-15/16 H:In. 13-12/16 Unit Weight Lbs.(kg) 86(39) Package Weight Lbs. 102 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 82 DB/50 DB MCA A 25 MOCP A 31 Fan Motor Full Load Amperage A 0.5+0.5 Fan Motor Output W 74+74 Airflow Rate CFM 3,880 Refrigerant Control Electronic Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Cross fin Sound Pressure Level,Coolingi dB(A) 52 Sound Pressure Level,Heatingz dB(A) 53 Compressor Type INVERTER-driven twin rotary Compressor Model MNB33FBRMC-L Outdoor Unit Compressor Rated Load Amps A 8 Compressor Locked Rotor Amps A 13 Compressor Oil Type//Charge oz. FV50S H 45 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W:In.(mm) 41-5/16(1050) Unit Dimensions D: In.(mm) 13+1-3/16(330+30) H: In.(mm) 52-11/16(1338) W: In. 42-15/16 Package Dimensions D: In. 17-11/16 H: In. 56-4/16 Unit Weight Lbs.(kg) 214(97) Package Weight Lbs. 245(111) Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: • 1 1 1 1 1 / 1 Indoor Unit PCA-A42KA7 Model Number PUZ-A42NKA7 Outdoor Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/0`DB Outdoor Unit Operating Heating Intake Air Temp(Maximum/Minimum) °F 70 DB, 59 WB/-4 DB,-4 WB Temperature Range Thermal Lock-out/Re-start Temperatures— °F -8/-4 DB Type R410A Refrigerant Charge Lbs,oz 10 Ibs,6 oz Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Maximum Piping Length Ft.(m) 165(50) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Notes AHRI Rated Conditions Cooling(Indoor H Outdoor) °F 80 DB,67 WB H 95 DB,75 WB (Rated data is 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB determined at a fixed compressor speed) 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB, 15 WB Conditions 4Heating at 5°F(Indoor H Outdoor) °F 70 DB,60 WB H-4 DB,-5 WB *Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle:0°F-115°F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed: Epoxy resin coating(at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: • 1 I I 1 High Efficiency(MERV 8)Filter Element ❑PAC-SE81 KF-E High-efficiency Filter Element ❑PAC-SH90KF-E Signal Receiver ❑PAR-SA9CA-E Wireless Remote Controller ❑PAR-FL32MA-E Wireless Remote Receiver ❑PAR-FA32MA-E Controller Kit(Sender&Receiver) ❑PAR-SL93B-E Controller Kit with i-see Sensor ❑PAR-SA92MW-E Backlit,Wall-mounted,Wireless Controller ❑MHK1 Portable Central Controller ❑MCCH1 Wired MA Controller ❑PAR-33MAA Simple MA Controller ❑PAC-YT53CRAU Touch MA Controller ❑PAR-CT01 MAU-SB Lockdown Bracket for Wireless, Hand-held,Remote Controller c RCMKP1 CB Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑MOS1 Flush Mount Remote Temperature Sensor ❑PAC-USSEN001-FM-1 Wireless Interface ❑PAC-USWHS002-WF-1 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01 UP-E IT Extender ❑PAC-WHS011E-E BACnee and Modbus Interface ❑PAC-UKPRC001-CN-1 External Fan/Heater Control Relay Adapter ❑CN24RELAY-KIT-CM3 Remote Operation Adapter(with wire terminals for remote ON/OFF and operation status/error)' ❑PAC-SF40RM-E i-see SensorM ❑PAC-SH91MK-E External Drain Pump ❑PAC-SH84DM-E Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 Btu/h ❑X87-721 -208/230V [recommended] Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑DPLS2 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ❑TAZ-MS303 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White ❑TAZ-MS303W Unable to use with wireless remote controller Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: •R P 1 I 1 Air Outlet Guide ❑PAC-SH96SG-E(two pieces are required) Front Wind Baffle 8 WB-PA3(two pieces are required) Drain Socket ❑PAC-SG61 DS-E M-NET Converter ❑PAC-SF83MA-E M-NET Converter ❑PAC-SJ95MA-E Control/Service Tool ❑PAC-SK52ST Condensing Unit Mounting Pad 24"x 42"x 3" ❑ULTRILITE2 Outdoor Unit Stand-12"High c QSMS1202M Outdoor Unit Stand-18"High ❑QSMS1802M Outdoor Unit Stand-24"High ❑QSMS2402M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel ❑QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel ❑QSWBSS 3/8"x 5/8"x 10'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-10 3/8"x 5/8"x 15'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-15 3/8"x 5/8"x 30'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 3/8"x 5/8"x 50'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-50 3/8"x 5/8"x 65'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-65 3/8"x 5/8"x 100'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-100 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Md DIMENSIONS: . .4 . ; . , PCA-A42 KA7 NOTES. Unit: in (mm) [FRONT VIEW] 8 1 1.useM10orW318 screw for anchor bolt. q 2.Please be sure when installing the drain pump(option parts), 10-1w refdgemnt pipe will be only upward. $ ava as 3 ElecVical box a3re ee m Ceiling ' —=a s1-v1e 1ss7 s„.ana�ce nan d1m 6 110 &71161 i B --—.—.—.----- de 11161a- g O O d � 11238 2 When electrical box is pulled down 1s-1ra 3e7 8 7 i In case of the rear pipe arrangement,make sure to remove the shaded portions from the independent piece. Then put the independent piece back in initial .(The position heat exchanger might be clogged because of dust) z s1 L168 1-7la da 11pr2p sumpen 111, fi(21 Lg in E ECtrICa bOX - g&3I4(1d931 an 5 — ___ _— -- 4L16233 e1s611eCn socket m m 77-1116(me liquid 0318(".52) iaiorainage Air oudet m In case of wireless 7-n zoo gas 0518(1015.88) :n a remote controller —i- When drain soael and i-see sensor is 1_1 w 7�is se (Optional Parts) s-nns zds Drainage Q1 Drainage pipe connedion(1(26mm)LD.) �2)Drainage pipe connedion(for the left arrangement) 3 Knockout hole for left drain-piping arrangement In case of wireless remote controller 4 Refrigerant-pipe connection '! and!-see sensor(ODtional Parts) (gas pipe side/flared connection) E,"y yoperanw, Em6.q oparenon Refrigerant-pipe connection wmm<c000a wnmaeati > (liquid pipe sidelflared connection) 6 Knockout hole for upper drain pipe arrangement "! Knockout hole for fresh air intake 03-15116(0100) of ao rs aaoarn a 8 Knockout hole for wiring arrangement 0718(022) iv, ` Accessory...Drain socket(1(26mm)LD.) °� n6mp Air intake Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: . .4 . ; . , PUY-A42NKA7(-BS) I''I Unit: mm<in> 1 FREE SPACE(Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLT 4 PIPING-WIRING DIRECTIONS Rear Air Intake I �v7 ueM1ew m hd. The diagram below shows a basic example. Dimensions cf space needed Please ware the unit gnnly Piping and wiring connections Ifw4bn.1.1 set) Explanhon of particular details am for service access are with 4 foundation W10<W318,)bolts. can be made from 4direcdons: given in the installation manuals etc. shown in the below diagram. (Bolts antl washers must be FRONT,Right,Rear and Be].. wl�Feet a purchased totally.) s —undation bolt height, Side Air Intake FOUNDATION j Sz� aaulce Tee Mem. sh Air Discharge g IFW2-3uudd!d,ntoawye>I 1050 W1-11/32, Side Airinteke 362,14-1/4> hLmnne[tion RearAir Intake (Rg�einao�oei18n .n5) Example of Notes 000 _ 7D ReM1lgemnl GAS pipe connection(FLARE) 015.88(NF) �000 Sent. .I �..Retlgemnl LIQUID pipe conneollon(FIARE) og.52(318F) •1...Inaicatlon of STOP VALVE connectlan location. Handle for HandleMmoNn Hanalemr oNng 3 �000 In rnp nefo ^ w ke = 0000 2 1 r w _ Piping Knockout Hole Details Fmnt in o er �..—n ugme—.. Rear nn�tiaehae�m Iblk <o�amhM1me m< am,a> aoa�h� ae,ounap— �nd:" eoa I een,e«nanal I a (eaases>wnoaoNl mmoM1mle t.x<,a,ewmwhl woaonl Uu<,memumuu wa.,re ,e<ne> fl e �rcdWnNg M1de aN<hy,®ImaM4) - = rcnOnnN) Oa.d., C,nd,,lN, an&,aea I 0 agM1l Nnp Mk e3i<I.,L9DkvAnA1 6 tl Ie3i<.IS91>NmtlmN) e11h1N albdmem i — o Bdbm YUt9M1ole a ,.�es egM1hhuMingkle �. 0 rcTmaN� ...— lam, 5aW<tL,U Fmm pPlnA 1me NnaNON) N '�ez d _ MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com GIRIM % s FORM#PCA-A42KA7/PUZ-A42NKA7(-BS)-201810 Intertek Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DESIGNED FOR P-SERIES AND PUMY OUTDOOR UNITS ONLY Job Name:City of Arlington MBR Support Bldg. - HVAC System Reference: Date: WB-PA3/WB-PA4/WB-PA5 GENERAL FEATURES MODEL REQUIRED PER OUTDOOR UNIT • WB-Series Wind Baffles allow P-Series outdoor units to operate at full Type and Quantity capacity to 0°F DB cooling. UNIT MODEL • Prevents wind from reversing outdoor fan rotation when un-energized. • Durable, low maintenance construction. PUY/Z-A24NHA4 1 • WB-PA3 Wind Baffle allows PUMY-P-NKMU1 outdoor units to operate down to 5°F DB at 100%capacity in cooling mode and down to-130 F DB PUY/Z-A30NHA4 1 in heating mode with a de-rate. PUY/Z-A36 N HA4 1 PLEASE NOTE PUY/Z-A42NHA4 2 • Install outdoor units with the back surface facing wall side to eliminate the PUY/Z-A42NHA5 2 effects of external wind. • Outdoor units should not be installed in an orientation or site where the PUZ-HA30NHA4 2 wind blows directly at the back of the unit. • Wind baffle should not be used where there is any obstacle at either side PUZ-HA36NHA4 2 or above the outdoor unit as the discharged air will be blocked. PUZ-HA30NHA5 2 SPECIFICATIONS PUZ-HA36NHA5 2 PUZ-HA42NKA 2 Color Matches P-Series Outdoor Unit PUMY-P36NHMU 2 Surface PUMY-P36NKMU1 2 Exterior Treatment Polyester Powder Paint PUMY-P48NHMU 2 Material Alloy Hot-Dip Zinc Coated Carbon Steel Sheet FUMY-P48NKMU1 2 Weight 8 Lbs.8 Oz. 7 Lbs.7.9 Oz. 8 Lbs.8 Oz. PUMY-P60NKMU/1 2 PUY/Z-A24N HA6 1 PUY/Z-A30N HA6 1 PUY/Z-A36 N HA6 1 PUY/Z-A42 N HA6 2 PUY/Z-Al2 N HA7 1 PUY/Z-A18N HA7 1 PUY/Z-A24N HA7 1 PUY/Z-A30N HA7 1 PUY/Z-A36NHA7 2 PUY/Z-A42NKA7 2 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC 1 • 'A Requirements of space for installation (1)One unit installation: [--6 or more Wall surface 20 or+more � 6 to 15 6 to 16 Ll O _ El O 2 � �20 or more 0 or more Wind Baffle � 6 to 16� Wall surface (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. Wall surface sto15 O O O O 6 to 16� 72Oormore 20m 20 or more 22.4 8 '5 �23 — � ALL DIMENSIONS IN INCHES 1 ALL DIMENSION±%32" 21 25.6 25 1 1 0.25 •5 4 PLCS �8 T Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC 1 • 'A4 Requirements of space for installation (1)One unit installation: �-6 or more Wall surface 20 or more 2x2-01/4 hole 6 to 16 6 to 16 O O O O O 20 or more 1 20 or more Wind Baffle Wall surface 22-3/8 6 to 16� (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. Wall surface 6 to 16 O O O O O Back View 6 or more 20 or more 20 or more 20 or more 7 7/8 ALL DIMENSIONS IN INCHES 21-118 ALL DIMENSIONS±%32" Side View Top View Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC 1 • 'A Requirements of space for installation (1)One unit installation: �-6 or more Wall surface 20 or more 4x 0114 L 6to16 6to16 O O O 0 0 20 or more 20 or more Wind Baffle 6 to 16� I� Wall surface (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. 0 0 Wall surface 9/16 6to16 77 O 3116 O O Back View 6 to 16 720ormore �2O or more 20 or more 23 7 7/8 1 31 6118 ALL DIMENSIONS IN INCHES 23 3/8 21 118 ALL DIMENSION±%32" Top Down View Side View Manufactured for MITSUBISHI ELECTRIC TRANE HVAC US LLC 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com FORM#WIND BAFFLE-201806 Specifications are subject to change without notice. C 2018 Mitsubishi Electric Trane HVAC US LLC Table of Contents SUBMITTAL DATA: PCA-A42KA7 & PUZ-A42NKA7(-BS) OVERVIEW 2 INDOOR UNIT FEATURES 2 OUTDOOR UNIT FEATURES 2 SPECIFICATIONS: PCA-A42KA7 & PUZ-A42NKA7(-BS) 3 ACCESSORIES: PCA-A42KA7 6 ACCESSORIES: PUZ-A42NKA7(-BS) 7 DIMENSIONS: PCA-A42KA7 & PUZ-A42NKA7 (-BS) 8 FRONT WIND BAFFLE 10 CITY OF ARLINGTON BUILDING DEPARTMENT A - ROVED DATEL BY NO CHANGES AUTHORIZED UNLESS APPkOVED BY THE BUILDING INSPECTOR RECEIVED MAR 15 2024 SUBMITTAL 1 DATA: 1 l P \ \ / 1 & P \ I 1 111 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Ak ELECTRIC Job Name: City of Arlington MBR Support Bldg. - HVAC System Reference: I Date: Indoor Unit: Outdoor Unit: PCA-A42KA7 4 PUZ-A42NKA7 � l ,,��llllllllll�lllllllillllllil,��, � �dllllll![illllllllll(IIIIIIIIIII[I[IIIIiII� 111(IIIllllll� IIIIIIIIIIII '�:� I�ul(111111�1Ii�i�fllllll�'' Illml�ll��llllllllill��, � ' i�11i11111111�jiIIIII�IIIIIIIIVI. ��Ilill�llil�llllllllllUllllllll�lll�lllllil� w AWL Wa INDOOR UNIT FEATURES • Airflow settings for high and low ceiling applications • Knock-out for outside-air intake • Optional i-see SensorTM for air distribution and energy saving • Auto fan speed mode • Filter status indicator • Easy-to-clean,washable filter • Suspends from ceiling for quick and easy installation • Ideal for larger retail stores,classrooms,and restaurants OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications,such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved A, ; . , Indoor Model Number PUZ-A42NKA7 Outdoor Maximum Capacity Btu/h 42,000 Rated Capacity Btu/h 42,000 Minimum Capacity I Btu/h 16,000 Maximum Power Input W 4,110 Cooling Rated Power Input W 4,110 Moisture Removal Pints/h 11.70 Sensible Heat Factor 0.69 Power Factor I % 95.60 Maximum Capacity Btu/h 48,000 Rated Capacity Btu/h 45,000 Minimum Capacity Btu/h 18,100 Heating at 47°Fz Maximum Power Input W 4,300 Rated Power Input W 3,480 r Power Factor % 94.60 Maximum Capacity Btu/h 35,000 Rated Capacity Btu/h 31,800 Heating at 17°F3 Maximum Power Input W 3,200 Rated Power Input W 3,160 SEER 17.60 EER'1 10.20 Efficiency HSPF(IV) 10.20 COP at 47°Fz 3.78 COP at 17°F3 2.94 Voltage,Phase,Frequency 208/230V, 1-phase,60 Hz Guaranteed Voltage Range V AC 198—253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 i Voltage:Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 30 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 2.00 ` Fan Motor Full Load Amperage A 0.97 Fan Motor Output W 160 Airflow Rate,Dry CFM 810-885-955-1025 Indoor Unit Airflow Rate,Wet CFM 740-810-885-955 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 39-41-43-45 iDrain Pipe Size In.(mm) 1-1/32(26) Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: • 1 I I l Indoor Model Number • do• I Condensate Lift Mechanism,Max.Distance In.(mm) n/a Heat Exchanger Type Plate fin coil External Finish Color White Munsell 6.4Y 8.9/0.4 W:In.(mm) 63(1600) Unit Dimensions D:In.(mm) 26-3/4(680) H:In.(mm) 9-1/16(230) W.In. 53-2/16 Package Dimensions D:In. 29-15/16 H:In. ! 13-12/16 Unit Weight Lbs.(kg) I 86(39) Package Weight Lbs. 102 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 82 DB/50 DB MCA A 25 MOCP A 31 Fan Motor Full Load Amperage A 0.5+0.5 Fan Motor Output W 74+74 'Airflow Rate CFM 3,880 Refrigerant Control I Electronic Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Cross fin Sound Pressure Level,Cooling' dB(A) 52 Sound Pressure Level, Heatingz dB(A) 53 Compressor Type INVERTER-driven twin rotary Compressor Model MNB33FBRMC-L Outdoor Unit Compressor Rated Load Amps A 8 Compressor Locked Rotor Amps A 13 Compressor Oil Type//Charge oz. FV50S//45 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W.In.(mm) 41-5/16(1050) Unit Dimensions D: In.(mm) 13+1-3/16(330+30) j H:In.(mm) ` 52-11/16(1338) W:In. 42-15/16 Package Dimensions D:In. 17-11/16 H:In. 56-4/16 1 Unit Weight Lbs.(kg) 1 214(97) Package Weight Lbs. I 245(111) Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • SPECIFICATIONS: , ■ I I ■ I Indoor Model Number Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/0"DB Outdoor Unit Operating Heating Intake Air Temp(Maximum/Minimum) °F 70 DB,59 WB/-4 DB,-4 WB Temperature Range i Thermal Lock-out/Re-start Temperatures— 'F 1 -8/-4 DB Type R410A [Refrigerant Charge Lbs,oz 10 Ibs,6 oz t—� Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Maximum Piping Length Ft.(m) 165(50) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Notes AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB `determined at a fixed compressor speed) 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions 4Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB "Wind baffles required to operate below 23°F DB in cooling mode.PUZ with wind baffle:0°F-115°F. "System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • 'Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: , A, High Efficiency(MERV 8)Filter Element ❑PAC-SE81 KF-E High-efficiency Filter Element _ i ❑PAC-SH90KF-E Signal Receiver f❑PAR-SA9CA-E i Wireless Remote Controller ❑PAR-FL32MA-E Wireless Remote Receiver ❑PAR-FA32MA-E Controller Kit(Sender&Receiver) ❑PAR-SL93B-E Controller Kit with i-see Sensor _ ❑PAR-SA92MW-E Backlit,Wall-mounted,Wireless Controller ❑MHK1 Portable Central Controller ❑MCCH1 Wired MA Controller ❑PAR-33MAA Simple MA Controller ❑PAC-YT53CRAU Touch MA Controller ❑PAR-CT01 MAU-SB Lockdown Bracket for Wireless,Hand-held,Remote Controller ❑RCMKPi CB `Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑MOS1 �Flush Mount Remote Temperature Sensor o PAC-USSEN001-FM-1 Wireless Interface ❑PAC-USWHS002-WF-1 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E BACnet®and Modbus Interface ❑PAC-UKPRC001-CN-1 External Fan/Heater Control Relay Adapter ❑CN24RELAY-KIT-CM3 Remote Operation Adapter(with wire terminals for remote ON/OFF and operation status/error)l ❑PAC-SF40RM-E i-see SensorTM71 ❑PAC-SH91MK-E External Drain Pump ❑PAC-SH84DM-E Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 Btu/h ❑X87-721-208/230V [recommended] i - - - - - — Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑DPLS2 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ❑TAZ-MS303 T 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White ❑TAZ-MS303W ` Unable to use with wireless remote controller —� Specifications are subject to change without notice. 0 2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved ACCESSORIES: PUZ-A42NKA7(--4,-, Air Outlet Guide ❑PAC-SH96SG-E(two pieces are required) Front Wind Baffle II WB-PA3(two pieces are required) Drain Socket ❑PAC-SG61 DS-E M-NET Converter ❑PAC-SF83MA-E M-NET Converter ❑PAC-SJ95MA-E Control/Service Tool ❑PAC-SK52ST Condensing Unit Mounting Pad 24"x 42"x 3" ❑ULTRILITE2 Outdoor Unit Stand-12"High ❑QSMS1202M Outdoor Unit Stand-18"High ❑QSMS1802M Outdoor Unit Stand-24"High ❑QSMS2402M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel ❑QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel ❑QSWBSS 3/8"x 5/8"x 10'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-10 3/8"x 5/8"x 15'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-15 3/8"x 5/8"x 30'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 3/8"x 5/8"x 50'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-50 3/8"x 5/8"x 65'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-65 3/8"x 5/8"x 100'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-100 Specifications are subject to change without notice ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: P / l I 1 & P / I 1 _ I PCA-A42KA7 1 NOTES Unit: in(mm) [FRONT VIEW] y. 1 Use M10or W31Sscrew foranchorholf 1 2 Please be sure when installing the drain pump(option pads), refrigerant pipe will he only upward al ( sin 4)n va enexee n do- 7 j s 7 M rase al vavppem�qe�w d W49W - arrow dx axrd pavaslaueadtpaidtMOnse pentrbcmcnuN e+—"uqc nqH Ee cgg00 bepuseal die;l) Mr cll CO[ L iwE >ti1 2 i Ipuid 0919(o952) a om�aa. A' -qfi fr i In.sedweekss gas m5190159M fwmafttnetl►r aYepp Yna�emime¢i ra > and.sr armor „aatm (OP""dw Pans) Drainage QDlanagaPDeconnealayt(2ranvn)ID) a'°� ((2 D amege ppa conneuorylor the let arrangement) a 3 KrWW hole br left Orain-pp4V arrar gemenl In case o1 wireless rertnte controldr 4 Refrge'ant•ppewnnocton +� and I See SenSOr10,0e0nal Pants)_ (gas pipesde1tared connection) aP.rw�.. 5Q Refrigerant-ppe connection (baud ppa sidelAavol cormedw) _ a 5 KnockoN hole fa upper dram ppe arrangement ® .� 1 Knockout note far treshau Intake 03.19116(0100) 8 Kn%kout hole for vwnngamangement0718((D22) a Accessory..Drain socket(1(26mm)I D.) a— Specifications are subject to change without notice. 0 2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved DIMENSIONS: / / I 1 ! I 1 PUY-A42NKA7(-BS) Unit:mm<in> 1 FREE SPACE(Around the 2 SERVICE SPACE 3 FOUNDATION SOL 4 P4PING151RING DIRECTIONS RearA r mtak n The d"—adurfhawbabare example Dimensions ayyace needed Pala—ft lM Nn'4 Pvngmdrxvlg ' v f""`r°itle1 FaplaabsdylRMr0elMda lorsenice aaxss are IealkuMdw M10M1'A9>I bo„£ Doha lr�el'aaa��°Rs giren.bandllliftommlYdc shesminlh.M.diag— (Boas Mdnkshesa+.11 ba MONT,".4m 4a W. purchased locally) V i Side Air Intake •Fountlalion boll heighl> 1i u.el. B a '��, tQ101t4i/ ONO Air Discharge i.}•Mx.�•weIMN•i •a.w .:.,.e•>r- n 01 Example of Notes O� 1O RdngenMGf5 pipem+Y�tU.iQ e15544aF) O RdrgemMIJWlDpW n*.. F1111Q e95AYOFF .1 hdcabond STOPMEmnnx90r—, •,; Randelcr - - •�SeS O U 4 0� MY•veb • 00 ?z = 2 Piping Knockout Hole Details - n eO' 0.ei•s �rx�e rn•I....e n..o °'e` I rnr•xo 4.. r _ 0 .>,Ins�r. nirrv.•ewe .f uv ••tee l 0 r.wa.. F�A4i g� aww>• � ,a AAMITSUBISHI k ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www mehvac.com ® Q. FORM#PCA-A42KA7/PUZ-A42NKA7(-BS)-201810 r Intertek Specifications are subject to change without notice. 0 2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved FRONT WIND BAFFLE • 1 • I I 1 DESIGNED FOR P-SERIES AND PUMY OUTDOOR UNITS ONLY ,lob Name:City of Arlington MBR Support Bldg. - HVAC System Reference: Date: WB-PA3/WB-PA4/WB-PA5 GENERAL FEATURES MODEL REQUIRED PER OUTDOOR UNIT • WB-Series Wind Baffles allow P-Series outdoor units to operate at full capacity to 0°F DB cooling. UNIT MODEL • Prevents wind from reversing outdoor fan rotation when un-energized. • Durable,low maintenance construction PUY/Z-A24NHA4 1 • WB-PA3 Wind Baffle allows PUMY-P-NKMU1 outdoor units to operate down to 5°F DB at 100%capacity in cooling mode and down to-131 F DB PUY/Z-A30NHA4 1 in heating mode with a de-rate. PUY/Z-A36NHA4 1 PLEASE NOTE PUY/Z-A42NHA4 2 • Install outdoor units with the back surface facing wall side to eliminate the PUY/Z-A42NHA5 2 effects of external wind. • Outdoor units should not be installed in an orientation or site where the PUZ-HA30NHA4 2 wind blows directly at the back of the unit. • Wind baffle should not be used where there is any obstacle at either side PUZ-HA36NHA4 2 or above the outdoor unit as the discharged air will be blocked. PUZ-HA30NHA5 2 SPECIFICATIONS PUZ-HA36NHA5 2 PUZ-HA42NKA 2 Color Matches P-Series Outdoor Unit PUMY-P36NHMU 2 Exterior Surface Polyester Powder Paint PUMY-P36NKMU1 2 Treatment PUMY-P48NHMU 2 Material Alloy Hot-Dip Zinc Coated Carbon Steel Sheet PUMY-P48NKMU1 2 Weight 8 Lbs.8 Oz 7 Lbs.7.9 Oz 8 Lbs.8 Oz. PUMY-P60NKMU/1 2 PUY/Z-A24NHA6 1 PUY/Z-A30NHA6 1 PUY/Z-A36NHA6 1 PUY/Z-A42NHA6 2 PUY/Z-Al2NHA7 1 PUY/Z-A18NHA7 1 PUY/Z-A24NHA7 1 PUY/Z-A30NHA7 1 PUY/Z-A36NHA7 2 PUY/Z-A42NKA7 2 Specifications are subject to change without notice ©2018 Mitsubishi Electric Trane HVAC US LLC DIMENSIONS: Requirements of space for installation (1)One unit installation: 6 or more Wall surface El 20 or more I I I 6to16 6to16 D --- T J I � 20 or more — 20 or more -Wind Baffle Wall surface 6 to 16--- f (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. Wall surface I 6to16 t 6 to 16 - - - 20 or more - ---z-20 or more - - 20 or more 224�T J—�e s -23 ALL DIMENSIONS IN INCHES ALL DIMENSION±Y32" 21 25 25.6 1 60.25 5 4 PLCS. B T Specifications are subject to change without notice. 0 2018 Mitsubishi Electric Trane HVAC US LLC 1 • 'A4 Requirements of space for installation (1)One unit installation: - 6 or more Nall surface 20 or more11zi/ 2x2-01/4 hole I , 6 l0 16 _ / —_6to16 / } I Y / 20 or more 20 or more 4- -� i Wind Baffle 22-3/8 6 to 16 - - Wall surface (2)Multiple Unit Installation:Installatlon of multiple units In series must be no more than five units. Wall surface - - -ato16 - Back View 6 or more — — �—-—20 or more --- --20 or more 20 or more 7 7/8 ALL DIMENSIONS IN INCHES — 21-118 - - ALL DIMENSIONS±Y32" Side View Top View Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC 1 • ' ' Requirements of space for installation (1)One unit installation: -/-6 or more Wall surface 20 or more 4x 0114- r 6to16 / 6to16 1/ 20 or more 20 or more Wind Baffle 1 Wall surface 6 to 16 — �— (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. Wall surface -9116 1 6to16 - _�Sl ? 3116 - I Back View 6 to 16 - - - 20 or more - - 20 or more - 20 or more 23 7 718 - - 1314 61l8 ALL DIMENSIONS IN INCHES r ALL DIMENSION AN" 23-318 - - - 21118 Top Dawn View Side View Manufactured for MITSUBISHI ELECTRIC TRANE HVAC US LLC 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com FORM#WIND BAFFLE-201806 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC i � "3 t•, � �' :. - --�' ,; _ � �, '�' ., ,�,. �� '1+ ,ice) .�`�� I _ °Y �, 1 ,�'n - � � , �. - U'i� _ - � �® � � - - U, .- .....�-- �- 1 1 �: o r a� � y - - - y - - � � _ _. � -�` r- - �. - - :N N Lr) rs ` l=� a � �S ueuey U m w .q� . aF IS tiiagmgN p a rcn �0J, U a ;S A Lmpeois Q' I R O 2 4..1 Cd aa, anb- peoalie8 p •• m� anb' JS@M N - 04 Y E � i L cri pox Ave _ _ _ _ _ - - - - - - - ------- ------------- State Route 9 NE O Permit#: 5895 Permit Date: 03/15/24 Permit Type: COMMERCIAL MECHANICAL Project Name: City Arlington MBR Support Building Applicant Name: D.K. Systems, Inc. /Dulce Herrera Applicant Address: D.K. Systems, Inc. /PO Box 886 Applicant, City, State, Burlington,WA 98233 Zip: Contact: Dulce Herrera Phone: 360-755-1555 Email: dulce@dksystemsinc.com Scope of Work: Like for Like replacement of existing Heat Pump - Replacing 50ft. of Refrigeration Line. Valuation: 25000.00 Square Feet: 4200 Number of Stories: 1 Construction Type: 11B Occupancy Group: B; Business ID Code: Permit Issued: Permit Expires: Form Permit Type: COMMERCIAL MECHANICAL Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00461802900100 154 W Cox Ave City of Arlington Contractors Contractor Primary Contact Phone Address Contractor Type License License# D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION COA 602 204 164Street CONTRACTOR D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION L&I DKSYSI*982L1Street CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 03/1V2024 COMMERCIAL BUILDING In Review MECHANICAL Attached Letters Date Letter Description 03/15/2024 Web Form-Building Ap ' do Uploaded Files Date File Name 03/18/2024 18962584-20240315 BLD5895 Application.pdf 03/18/2024 18962582-20240315 BLD5895 SitePlan.pdf 03/18/2024 18962583-20240315 BLD5895 Specs.pdf Ob80897cb5ecb8244861371693973089 commercial mechanical permit application - 03/15/2024 city arl' ton mbr su ort ld df Y� mg pP—�—g-P 03/15/2024 5590dl7b6f8c4fad29237b89df919b63 spec sheets - city arlington mbr support bldg_pdf 03/15/2024 9941fad00aba72c20bfca6clbaebda0a site plan - city arlington mbr support bldg_pdf Permit#: 5895 Permit Date: 03/15/24 Permit Type: COMMERCIAL MECHANICAL Project Name: City Arlington MBR Support Building Applicant Name: D.K. Systems, Inc. /Dulce Herrera Applicant Address: D.K. Systems, Inc. /PO Box 886 Applicant, City, State,Burlington,WA 98233 Zip: Contact: Dulce Herrera Phone: 360-755-1555 Email: duke@dksystemsinc.com Scope of Work: Like for Like replacement of existing Heat Pump - Replacing 50ft. of Refrigeration Line. Valuation: 25000.00 Square Feet: 4200 Number of Stories: I Construction Type: 11B Occupancy Group: B; Business ID Code: Permit Issued: 04/03/2024 Permit Expires: 09/30/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00461802900100 125 W Haller Ave City of Arlington 090 MASTER ADDRESS Contractors Contractor Primary Contact Phone Address Contractor Type License License# D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION COA 602 204 164 Street CONTRACTOR D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION L&I DKSYSI*982L1 Street CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status The site contact is Nels Rasmussen,Utilities C14. Program&Project 04/17/2024 MECHANICAL Coordinator at 360-322- 04/19/2024 04/19/2024 BUILDING Approved FINAL 8981. Thank you, Plan Reviews Date Review Type Description Assigned To Review Status 03/18/2024 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Mechanical Commercial Plan Review Table 4-1 $381.06 Processing/Technology $25.00 Heat Pump-Condensing Unit Enter#of units $25.00 Total $431.06 Attached Letters Date Letter Description 04/03/2024 Building Permit 03/15/2024 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 03/18/2024 XBP Conf: $381.06 168196776 04/03/2024 XBP Conf: $50.00 169501624 Outstanding Balance $0.00 Notes Date Note Created By: 03/18/2024 Application has incorrect address for building. Kristin Foster Uploaded Files Date File Name 04/05/2024 19589503-20240315 BLD5895 Application.pdf 04/05/2024 19589502-20240401 BLD5895 ApprovedDocuments.pdf 03/18/2024 18962582-20240315 BLD5895 SitePlan.pdf