Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
16419 Smokey Point Blvd_BLD5969_2026
i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration 0 Replaced ❑ Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 16419 Smokey Point Blvd. Project Valuation: 10,000.00 Lot#: Parcel ID No.: 0207290 / 31052800201000 preferred Contact: O Owner 0 Contractor Project Description: Replace Like for Like (1)Furnace, and (1)Air Conditioner. **Please Note:Work will take place at the Bank Owner Name: Coastal Community Bank Office No.: 425-349-2658 Email Address: sgarber@coastalbank.com Steve Garber,VP Facilities/Finance Cell No.: Mailing Address: 10520 19th AVE SE city: Everett state: WA zip:98208-4276 Contractor Name: D.K. Systems, Inc. Office No.: 360-755-1555 Email Address: dulce@dksystemslnc.com Cell No.: Mailing Address: P.O. BOX 886 city: Burlington State: WA zip: 9823 L&I Contractor License Number: D KSYS I*982 L 1 Expiration Date: 06/21/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable O CSST O Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" O 5/8 O 3/4" O 1" O 11/2" O 2" Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. DuIce Herreraoaaa'o°gmIh9s9sa tleP°m�� SY m � efPa DuIce Herrera 05/01/2024 Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Conditioning Unit<_ 100 Btu h 1 x $ 15.00 = $15.00 Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu h<50h x $ 25.00 = $ Boiler>1.5 million Btu/h<SOhp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h 1 x $ 25.00 = $25.00 Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Gas Fired Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Gas Fired Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping for each additional unit > 5 x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 _ $ mechanical code,not otherwise specified Package Units:5 100 Btu > 100 Btu x $ 25.00 $50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee all x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters>100 Btu h x $ 25.00 = $ Variable Air Volume Boxes (part of Air x $ 10.00 = $ Conditioning System) Wall Heaters-Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2024 Page 2 of 3 Not Applicable PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 ' , sr -16 N Y (` > ' 4 _ = m � -Coasta munrty�• g, _ — -- a `I �..a. > - `Bayshor o e-- _.J _. Amiriistrative Office � m ' ;r l I - t Blvd Smokey Point Coastal Community Bahk :16ayshore Concrete `14�4Administrative Office _ . >~� ram, _ '•: ME -- •• ti l•— 1 � :, ♦ —��. -fit rl► Table of Contents Indoor Unit 2 Furnace 7 Outdoor AC Unit 14 Indoor Unit Outline Drawing for Upflow models:4PXCAU24BS3HAB,4PXCAU32BS3HAB,4PXCBU24BS3HAB,4PXCBU30BS3HAB,4PXCCU30BS3HAB,4PXCBU36BS3HAB, D 4PXCCU36BS3HAB,4PXCBU42BS3HAB,4PXCCU42BS3HAB,4PXCBU48BS3HAB,4PXCCU48BS3HAB,4PXCDU48BS3HAB,4PXCCU60BS3HAB,4PXCDU60BS3HAB and Downflow models:4PXCBD30BS3HDB,4PXCBD36BS3HDB,4PXCCD36BS3HDB,4PXCBD42BS3HDB,4PXCCD42BS3HDB,4PXCCD60BS3HDB, 4PXCDD60BS3HDB D e 2-7/8 114 1-114 19-3/8 O O O O O O 2-1/2 A I Ccmfo 4TMcoil O II-718 CJD p 0 1-112 -- ® o v Il4 ¢3/4 NIT �— 19-I12 �• 3-1/2 1-3// PLUGGED SECONDARY DRAIN OPENING 21-1112 WRAPPER rf FOR VERTICAL POSITION pia/d RY DRAIN NPT rf ' PAA C FOR VERTICAL POSITION I— OPENING IN WRAPPER 0. B (D FIGURE A O C 0 4PXCBU30BS3 4PXCBU36BS3 4PXCCU36BS3 4PXCBU42BS 4PXCCU42BS3 4PXCCU60BS3 4PXCDU60BS3 0 MODEL 4PXCAU24BS3 4PXCAU32BS3 4PXCBD42BS 4PXCCD42BS3 PXCDU48BS3 4PXCBU24BS3 4PXCCU30BS3 4PXCBU48BS 4PXCCU48BS3 4PXCBD30BS3 4PXCBD36BS3 4PXCCD36BS3 4PXCCD60BS3 4PXCDD60BS3 SEE FIGURE FIGURE A FIGURE A FIGURE B FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE B 0 (\0 SHIPPING WEIGHT(LBS.) 39 43 47 54 56 61 64 68 73 77 42 41) O ^' REFRIGERANT CONTROL TXV(NON- EED) —• HEIGHT'A"(IN.) 17-5/8 22-1/2 17-5/8 22-1/2 22-1/2 26-7/8 26-7/8 26-7/8 30-3/4 30-3/4 17-5/8 17-1/2 N �^ OVERALL WIDTH"B'(IN.) 14-1/2 14-1/2 17-1/2 17-1/2 21 17-1/2 21 24-1/2 21 24-1/2 17-1/2 21 O Q vJ OPENING WIDTH"C'(IN.) 13-5/8 13-5/8 16-5/8 16-5/8 20-1/8 16-5/8 20-1/8 23-5/8 20-1/8 23-5/8 16-5/8 20-1/8 C TOP OPENING"D" 12-3/4 12-3/4 15-3/4 15-3/4 19-1/4 15-3/4 19-1/4 22-3/4 19-1/4 22-3/4 15-3/4 19-1/4 GAS CONNECTION 314 7/8 314 fii—ww� v LIQUID CONNECTION 3/8 O c MATCHED FURNACE WIDTH 14-1/2 14-1/2 17-1/2 17-1/2 21 17-1/2 21 24-1/2 21 24-1/2 17-1/2 21 C (NO ADAPTER RQUIRED) DRAIN PAN P TIC rf From Dwg D346711 RevB z =• C Z m > N 0 0 co co 0 0 E 2 �o Li Qo 0 o� 0 � > 3 O o v= m ml Lu 0 0 0 (D LLi -i- 0 0 0 - o a � p o o 0 - 0 1 t � 0 u a PRODUCT SPECIFICATIONS[']--4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED UPFLOW COMFORT TM COILS[21 Model 4PXCAU24BS3HAB 4PXCAU32BS3HAB 4PXCBU24BS3HAB 4PXCBU30BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-2.0 1.5-3.0 1.5-2.0 1.5-3.0 Rows/F.P.I. 2/20 2/20 2/20 3/14 Face Area(sq.ft.) 3.0 4.5 3.0 3.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size -Gas(in.) 3/4 3/4 3/4 3/4 Line Size -Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 17.5 x 26.5 26.35 x 17.5 x 26.5 21.35 x 20.5 x 26.5 21.35 x 20.5 x 26.5 Uncrated 17.6 x 14.5 x 21.5 22.6 x 14.5 x 21.5 17.6 x 17.5 x 21.5 17.6 x 17.5 x 21.5 WEIGHT(lbs) Shipping-- Net 39/31 43/35 42/34 47/39 2 4PXCV-SUB-4A-EN Model 4PXCCU30BS3HAB 4PXCBU36BS3HAB 4PXCCU36BS3HAB 4PXCBU42BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/F.P.I. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 24 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6x21x21.5 22.6 x 17.5 x 21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) Shipping-- Net 49/41 54/46 56/48 61 /53 Model 4PXCCU42BS3HAB 4PXCBU48BS3HAB 4PXCCU48BS3HAB 4PXCDU48BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 2.0-4.0 3.0-5.0 3.0-5.0 Rows/F.P.I. 3/14 3/14 3/14 3/14 Face Area(sq.ft.) 5.5 6.0 6.0 6.0 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 30.65 x 24 x 26.5 30.65 x 20.5 x 26.5 30.65 x 24 x 26.5 30.65 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 26.9 x 17.5 x 21.5 26.9x21 x21.5 26.9 x 24.5 x 21.5 WEIGHT(Ibs) Shipping-- Net 64/56 61 /53 64/56 68/60 Model 4PXCCU60BS3HAB 4PXCDU60BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN Cooling Capacity(Tons) 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/12 3/12 Face Area(sq.ft.) 6.0 6.0 Tube Size 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Drain Conn.Size (in.) 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing REFRIGERANT R-410A R-410A CONNECTIONS BRAZED BRAZED Line Size Gas (in.) 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D Crated (H x W x D) 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 30.7 x 21 x 21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping -- Net 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps (A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Left with Kit 4PXCV-SUB-4A-EN 3 PRODUCT SPECIFICATIONSM --4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED DOWNFLOW COMFORT TM COILS [21 Model 4PXCBD30BS3HDB 4PXCBD36BS3HDB 4PXCCD36BS3HDB 4PXCBD42BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/FIR I. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 20.5 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6x17.5x21.5 22.6 x 17.5 x 21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) 47/39 Shipping-- Net 54/46 56/48 61 /53 Model 4PXCCD42BS3HDB 4PXCCD60BS3HDB 4PXCDD60BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/14 3/12 3/12 Face Area(sq.ft.) 5.5 6.0 6.0 Tube Size 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D Crated (H x W x D) 30.65 x 24 x 26.5 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 30.7x21 x21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping-- Net 64/56 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Right with Kit 4 4PXCV-SUB-4A-EN PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(SCFM)VS. PRESSURE DROP ACROSS WET COIL PRESSURE DROP (INCHES OF WATER COLUMN) MODEL 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4PXCAU24BS3HAB 340 430 510 585 650 715 775 4PXCAU32BS3HAB 570 725 860 985 1100 1200 1305 4PXCBD30BS3HDB 510 645 760 865 965 1055 1140 4PXCBD36BS3HDB 645 810 950 1080 1200 1305 1410 4PXCBD42BS3HDB 585 745 880 1000 1115 1220 1315 4PXCBU24BS3HAB 435 555 660 755 840 920 995 4PXCBU30BS3HAB 525 665 1790 900 1000 1095 1180 4PXCBU36BS3HAB 655 825 970 1100 1220 1330 1435 4PXCBU42BS3HAB 625 790 935 1065 1185 1295 1400 4PXCBU48BS3HAB 640 815 965 1095 1220 1335 1445 4PXCCD36BS3HDB 760 955 1125 1275 1415 1540 1665 4PXCCD42BS3HDB 695 880 1040 1185 1315 1440 1555 4PXCCD60BS3HDB 720 920 1095 1250 1390 1525 1655 4PXCCU30BS3HAB 540 680 805 920 1020 1120 1210 4PXCCU36BS3HAB 770 970 1145 1300 1440 1570 1696 4PXCCU42BS3HAB 735 930 1105 1255 1400 1530 1655 4PXCCU48BS3HAB 760 965 1140 1300 1445 1580 1710 4PXCCU60BS3HAB 740 940 1120 1280 1425 1565 1695 4PXCDD60BS3HDB 815 1040 1235 1410 1575 1725 1870 4PXCDU48BS3HAB 870 1100 1300 1485 1650 1805 1950 4PXCDU60BS3HAB 835 1065 1265 1 1445 1615 1770 1915 Mechanical Specifications General These coils are A.H.R.I.certified with Trane The dedicated Upflow and Downflow coils are designed for cooling and heat pump and American Standard's applications. The coil uses 3/8" seamless aluminum tubing mechanically bonded to matching condensing units. aluminum plate fin. Accessories Refrigerant for the PXC is controlled with a factory installed Non-Bleed TXV Evaporator Defrost Control installed on coil refrigerant control. Refrigerant connections are brazed fittings. for lower ambient operating The coil cabinet has a removable front and interior access panel for evaporator coil conditions. entering air surface cleaning. Upflow coils can be converted to horzontal left and downflow coils can be converted to horizontal right with optional kit purchased separately. About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4PXCV-SUB-4A-EN 29 Apr 2021 Supersedes (New) 02021 Furnace Submittal Upflow / Horizontal Left/Right Single Stage Condensing Gas Fired Furnace 100,000 BTU H , Convertible to Horizontal Horizontal Right or Horizontal Left S9X1C10005PSBA S9B1C10005PSAA o � 0 Note:Graphics in this document are for representation only.Actual model may differ in appearance. TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July2019 S9X1C1000-SUB-1A-EN 4fR"IngersollRand Outline Drawings Table 1. 21" Upf low Cabinet 5 T-F-r ❑® _ 2 S9X1C1000-SUB-1A-EN Product Specifications MODEL S9X1C10005PSBA(a) MODEL S9X1C10005PSBA(a) S9B1C10005PSAA S9B1C10005PSAA TYPE Upflow/Horizontal Gauge(Fired) 20 RATINGS(b) ORIFICES—Main Input BTUH 100,000 Nat.Gas Qty.—Drill Size 5-45 Capacity BTUH(ICS)(c)(d) 97,000 LP Gas Qty.—Drill Size 5-56 Temp.Rise(Min.-Max.) 40-70 GAS VALVE Redundant-One Stage AFUE(%)S9X1/S9B1(d) 96.0/92.1 PILOT SAFETY DEVICE BLOWER DRIVE DIRECT Type 120 V SiNi Igniter Diameter—Width(In.) 11 X 10 BURNERS—Type Multiport Inshot No.Used 1 Number 5 Speeds(No.)(e) 9 POWER CONN.—V/Ph/Hz(h) 120/1/60 CFM vs.in.w.g. See Fan Performance Ampacity(In Amps) 13.3 Table Motor HP 1 Max.Overcurrent Protection(Amps) 15 RPM 1075 PIPE CONN.SIZE(in.) 1/2 Volts/Ph/Hz 120/1/60 DIMENSIONS H x W x D FLA 10 Uncrated(In.) 34 x 21 x 28-3/4 COMBUSTION FAN—Type Centrifugal Crated(In.) 35-1/2 x 23 x 30-7/8 Drive—No.Speeds Direct-1 WEIGHT Motor HP—RPM 3300 Shipping(Lbs.)/Net(Lbs.) 155/145 Volts/Ph/Hz 120/1/60 (a) Meets Energy Star b) For U.S.applications,above input ratings(BTUH)are up to 2,000 FLA 0.66 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are FILTER—Furnished? No up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. Type recommended High Velocity Central Furnace heating designs are certified to ANSI Z21.47/CSA Hi Vel.(No. Size Thk.) 1—20x25—1 in. 2.3. (d) Based on U.S.government standard tests. VENT PIPE DIAMETER—Min(in.) 2 Round (e) 9 Speed constant torque ECM blower motor M(9) M Refer to the Vent Length Table in the Installer's Guide. HEAT EXCHANGER (9) All furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Type—Fired 409 Stainless Steel Electrical Code;however,installations must comply with local codes. —Unfired 29-4C Stainless Steel S9X1 C1000-SUB-1 A-EN 3 Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 1013 847 680 514 348 Watts 104 116 129 142 155 2 SUM 1261 1126 990 854 718 Watts 168 185 202 219 236 3 SCFM 1519 1407 1296 1184 1072 Watts 267 290 313 336 358 4 SUM 1554 1446 1337 1229 1120 Watts 283 307 330 353 377 S9X1C100U5PSBA 5 SUM 1749 1651 1554 1457 1359 S9B1C10005PSAA Watts 385 411 436 462 488 6 SUM 1868 1778 1688 1599 1509 Watts 464 491 519 546 574 7 SUM 2018 1936 1853 1770 1688 Watts 573 602 631 660 689 8 SUM 2191 2112 2033 1954 1875 Watts 718 750 782 815 847 9 SUM 2395 2303 2212 2120 2028 Watts 966 981 996 1012 1027 CFM Versus Temperature Rise Table 2. Heating Table — Upflow CFM VS.TEMPERATURE RISE MODEL 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X1C10005PSBA 65 61 57 55 53 49 46 44 43 S9B1C10005PSAA 4 S9X1C1000-SUB-1A-EN General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the S9X1 Furnace is certified by the manufacturer to leak American Gas Association for both natural and L.P. 1%(1.4%for S9131)or less of nominal air conditioning gas. Limit setting and rating data were established and CFM delivered when pressurized to.5"water column approved under standard rating conditions using with all inlets,outlets,and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. QUICK HEATING The S-Series furnace has a special type 29-4CT"'stainless steel secondary heat exchanger to reclaim Durable,cycle tested, heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and Heavy gauge steel and "wrap-around"cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside. enamel finish for strength and beauty. Every BURNERS orientation has at least two venting options.There are no knockouts on cabinet. Multiport Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot INTEGRATED SYSTEM CONTROL Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat. Complete front service access. valve,flame control and includes self diagnostics for a. Low energy power venter ease of service.Also contains dry contacts for EAC and HUM. b.Vent proving pressure switches. S9M C1000-SUB-1 A-EN 5 Features and Benefits UP TO 96.0%AFUE ON S9X1 FURNACE MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections; no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34 INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Works great with larger,high-efficiency coils Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3—WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 6 SKU's — Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 5 SKU's — Downflow VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in. H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CFM/ton Blower deck has full-length rails for easy removal and REGULATORY replacement, regardless of poise All models are airtight; 1%or less air leakage as per THREE—WAY MULTI-POISE (UPFLOW, ASHRAE 193 0.4%for S9131) HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED Open vestibule design provides a full 34" high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install (no conversion kits required) Widths are industry standard: 17.5",21",and 24.5" Every model has at least two venting options Depth remains approximately 28" When in horizontal,trap extends only about 2" Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as,other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup/Status/Diagnostics/Digital Display Vent table improvements including longer vent No dip switches lengths;2" pipe can be used up to 100K 6 SM1C1000-SUB-1A-EN 4j:Pingersoll Rand© Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club CarT), Ingersoll RandID, Thermo Kingg and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. 4$Vingersoll Rand Tr THERMO KING TRANE® ingersollrand.com m C Eta �s ril7i.71Y13 Mi. Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X1C1000-SUB-1A-EN 24Jul2019 Supersedes(New) ©2019 Ingersoll Rand Outdoor AC Unit as TRANE° Submittal Split System Cooling 4TTR4048N1000A \1 V �^ Note: "Graphics in this document are for representation only.Actual model may differ in appearance." March 2022 4TTR4048N-SUB-1A-EN 1 � n N = TECH NO LOG I ES' 0 TRAKE® B C i SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 152A (5 FEET) ABOVE UNIT, UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL K 25 (1 A 22.2 (1/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA, K.O. WITH 22.2 (7/8) DIA, HOLE IN CONTROL BON BOTTOM FOR ELECTRICAL POWER SUPPLY H F II III I L J K.O. FOR ALTERNATE G ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, "E' I,D. FEMALE BRAZE -7 CONNECTION WITH I/4" SAE GAS LINE 114 TURN BALL SERVICE VALVE, "D" FLARE PRESSURE TAP FITTINGS. I.D. FEMALE BRAZED CONNECTION WITH I/4" SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4TTR4048N 4 741 946 870 7/8 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-3/4) (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power[dB] Model Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR4048N 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270-2008*For reference only 2 4TTR4048N-SUB-1 A-E N 0 TRANS° Product Specifications OUTDOOR UNIT(a)(b) 4TTR4048N1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(c) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 24 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT RTG.—MAX.(AMPS) 40 M Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATUFFO-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 18.5—124 (e) Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor FACTORY INSTALLED start.No means no start components.Yes means quick start kit START COMPONENTS(e) NO(Uses BAYKSKT263) components.PTC means positive temperature coefficient starter. Optional kit shown. INSULATION/SOUND BLANKET NO M Standard Air—Dry Coil—Outdoor (g) This value approximate.For more precise value see unit nameplate. COMPRESSOR HEAT NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid OUTDOOR FAN PROPELLER 60 ft.For greater length consult refrigerant piping software Pub.No. 32-3312-0*(*denotes latest revision). DIA.(IN.)—NO.USED 27.5—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0IN.W.G.M 3970 NO.MOTORS—HP 1-1/5 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 208/230/1/60 F.L.AMPS 1.05 OUTDOOR COIL—TYPE SPINE FINw ROWS—F.P.1. 1-24 FACE AREA(SQ.FT.) 19.07 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 5 LBS.,3 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 7/8 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10*F DIMENSIONS H X W X D CRATED(IN.) 34.4 x 35.1 x 38.7 WEIGHT SHIPPING(LBS.) 212 NET(LBS.) 189 4TTR4048N-SUB-1 A-E N 3 0 TRANE® Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection. Other features include: Centrifugal unit,ten (10)feet of tested connecting line,and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match.This unit Condenser Coil is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer.The coil is protected on all four furnace coils that are AHRI certified.The unit is certified sides by louvered panels. to UL 1995. Exterior is designed for outdoor Low Ambient Cooling application. As manufactured,this system has a cooling capacity to Casing 55°F.The addition of an evaporator defrost control Unit casing is constructed of heavy gauge,galvanized permits operation to 40°F.The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish.The corner panels are prepainted.All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and low and high pressure and automatic change over).Sub-base to match switches.A factory supplied,field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 4TTR4048N-SUB-1A-EN TRAME® Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. As • Unitary Small AC AHRI Standard 210/240 1 C Certification applies only anthen the co,plele syste, UL US LISTED The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory. org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4TTR4048N-SUB-1A-EN 28Mar2o22 Supersedes(New) ©2022 Trane Table of Contents Indoor Unit 2 Furnace 7 Outdoor AC Unit 14 CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DA SIntBy' NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR RECEIVED MAY 0 12924 4PXCV-SUB-4A-EN TAG: -M 1 2 - 5 Ton Cased Aluminum Dedicated Upflow and Downflow Convertible to Horizontal with Kit = o m U) m U � _ m U 7 Q (0 x CO (D U❑ m X m ¢ ❑ M CL 2 a ul u'S Ol m m❑ x ❑ U Q 2 d=(� o �((jm mN < LL m m0(O �� ¢ of to MVU - XX w N X xa - o XIL CI) [L m w < M. _ U m❑ (L=(� x X N ( m m m C pn Q V❑ m ¢ CO U m ¢ _ _ _ ((�pU o N CO U X LL o X CL a M t V Cd U Q < _ X =CO Cnm UUU 0 � N CO N O a c c w Q U X m N N m a p sf X V m m m _ N EL UUU m x x a F x MA m 1 - . ♦ do j C+� Nav o -lCC +� wr • r d: mo Q S U Q= O O x x CL�+ CL << -� NM e� oo _ m a a s U 006 aN x m Cy O C7 c aeo 1 N 0:3Q] o o a _ 3 m a O w U X S 6 U 0 d 0. i - x �=0o 1 z z 3w CD z z (p O O 0 x ° _ x x o 0 o z CO C(O _ w Z a o U w LL w U❑U �_ z �' a 3 0 z Z 0¢ a — X X J a LL w w 0 0 < z 0 0 0 v m v a 1. W. W. o o ° `� ° .? o m � m 0 0 C0 0 3 0 E 2 <_ LL �o ¢o 0 06 W_ o > 3 O -act- 0/ > U m �6 40 O O i_ ° ® U � p 0 0 0 a PRODUCT SPECIFICATIONSM--4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED UPFLOW COMFORTTm COILS[2] Model 4PXCAU24BS3HAB 4PXCAU32BS3HAB 4PXCBU24BS3HAB 4PXCBU30BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-2.0 1.5-3.0 1.5-2.0 1.5-3.0 Rows/F.P.I. 2/20 2/20 2/20 3/14 Face Area(sq.ft.) 3.0 4.5 3.0 3.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV - Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing_ See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 3/4 3/4 3/4 Line Size- Liquid(in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 17.5 x 26.5 26.35 x 17.5 x 26.5 21.35 x 20.5 x 26.5 21.35 x 20.5 x 26.5 Uncrated 17.6 x 14.5 x 21.5 22.6 x 14.5 x 21.5 17.6 x 17.5 x 21.5 17.6 x 17.5 x 21.5 WEIGHT(lbs) Shipping--Net 39/31 43/35 42/34 47/39 2 4PXCV-SUB-4A-EN Model 4PXCCU30BS3HAB 4PXCBU36BS3HAB 4PXCCU36BS3HAB 4PXCBU42BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/F.P.I. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size- Gas(in.) 3/4 7/8 7/8 7/8 Line Size- Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 21.35 x 24 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6x21x21.5 22.6 x 17.5 x 21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) Shipping--Net 49/41 54/46 56/48 61 /53 Model 4PXCCU42BS3HAB 4PXCBU48BS3HAB 4PXCCU48BS3HAB 4PXCDU48BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 2.0-4.0 3.0-5.0 3.0-5.0 Rows/FRI. 3/14 3/14 3/14 3/14 Face Area(sq.ft.) 5.5 6.0 6.0 6.0 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawina See outline drawmn REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 7/8 Line Size- Liquid in. 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 30.65 x 24 x 26.5 30.65 x 20.5 x 26.5 30.65 x 24 x 26.5 30.65 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 26.9 x 17.5 x 21.5 26.9x21 x21.5 26.9 x 24.5 x 21.5 WEIGHT(Ibs) Shipping--Net 64/56 61 /53 64/56 68/60 Model 4PXCCU60BS3HAB 4PXCDU60BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN Cooling Capacity(Tons) 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/12 3/12 Face Area(sq.ft.) 6.0 6.0 Tube Size 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing REFRIGERANT R-410A R-410A CONNECTIONS BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 Line Size -Liquid (in.) 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D Crated(H x W x D) 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 30.7 x 21 x 21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping--Net 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Left with Kit 4PXCV-SUB-4A-EN 3 PRODUCT SPECIFICATIONSO]--4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED DOWNFLOW COMFORT TM COILS[21 Model 4PXCBD30BS3HDB 4PXCBD36BS3HDB 4PXCCD36BS3HDB 4PXCBD42BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/F.P.I. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 7/8 7/8 7/8 Line Size Liquid(in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 21.35 x 20.5 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6 x 17.5 x 21.5 22.6 x 17.5 x 21.5 22.6x21 x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) 47/39 Shipping--Net 54/46 56/48 61 /53 Model 4PXCCD42BS3HDB 4PXCCD60BS3HDB 4PXCDD60BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/14 3/12 3/12 Face Area(sq.ft.) 5.5 6.0 6.0 Tube Size 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED Line Size -Gas(in.) 7/8 7/8 7/8 Line Size -Liquid(in.) 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D Crated(H x W x D) 30.65 x 24 x 26.5 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 30.7x21 x21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping--Net 64/56 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). Refer to the Split System Ouldoor product information site or www.ahrinet.org [2]Convertible to Horizontal Right with Kit 4 4PXCV-SUB-4A-EN PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(SCFM)VS.PRESSURE DROP ACROSS WET COIL PRESSURE DROP(INCHES OF WATER COLUMN) MODEL 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4PXCAU24BS3HAB 340 430 510 585 650 715 775 4PXCAU32BS3HAB 570 725 860 985 1100 1200 1305 4PXCBD30BS3HDB 510 645 760 865 965 1055 1140 4PXCBD36BS3HDB 645 810 950 1080 1200 1305 1410 4PXCBD42BS3HDB 585 745 880 1000 1115 1220 1315 4PXCBU24BS3HAB 435 555 660 755 840 920 995 4PXCBU30BS3HAB 525 665 790 900 1000 1095 1180 4PXCBU36BS3HAB 655 825 970 1100 1220 1330 1435 4PXCBU42BS3HAB 625 790 935 1065 1185 1295 1400 4PXCBU48BS3HAB 640 815 965 1095 1220 1335 1445 4PXCCD36BS3HDB 760 955 1125 1275 1415 1540 1665 4PXCCD42BS3HDB 695 880 1040 1185 1315 1440 1555 4PXCCD60BS3HDB 720 920 1095 1250 1390 1525 1655 4PXCCU30BS3HAB 540 680 805 920 1020 1120 1210 4PXCCU36BS3HAB 770 970 1145 1300 1440 1570 1696 4PXCCU42BS3HAB 735 930 1105 1255 1400 1530 1655 4PXCCU48BS3HAB 760 965 1140 1300 1445 1580 1710 4PXCCU60BS3HAB 740 940 1120 1280 1425 1565 1695 4PXCDD60BS3HDB 815 1040 1235 1410 1575 1725 1870 4PXCDU48BS3HAB 870 1100 1300 1485 1650 1805 1950 4PXCDU60BS3HAB 835 1065 1265 1445 1615 1770 1915 Mechanical Specifications General These coils are A.H.R.I.certified with Trane The dedicated Upflow and Downflow coils are designed for cooling and heat pump and American Standard's applications. The coil uses 3/8"seamless aluminum tubing mechanically bonded to matching condensing units. aluminum plate fin. Accessories Refrigerant for the PXC is controlled with a factory installed Non-Bleed TXV Evaporator Defrost Control installed on coil refrigerant control. Refrigerant connections are brazed fittings. for lower ambient operating The coil cabinet has a removable front and interior access panel for evaporator coil conditions. entering air surface cleaning. Upflow coils can be converted to horzontal left and downflow coils can be converted to horizontal right with optional kit purchased separately. About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4PXCV-SUB-4A-EN 29 Apr 2021 Supersedes (New) ©2021 Furnace Submittal Upflow / Horizontal Left/Right Single Stage Condensing Gas Fired Furnace 100,000 BTU H Upflow,Convertible to Horizontal Right or Horizontal Left S9X1C10005PSBA v S9l31 C10005PSAA • o Note:Graphics in this document are for representation only.Actual model may differ in appearance. TAG: - A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July 2019 SM C1000-SUB-1 A-EN 1O�1IngersollRand. Outline Drawings Table 1. 21"Upflow Cabinet .i;i; N ek TN� -gs e17 Y9�� �Y o� a8Y oYY T J J-1 P N w< � - x 1 - a a s: Ea teS 0.1 0. 2 S9X1C1000-SUB-1A-EN Product Specifications S9X1C100USPSBA(8) S9X1C100USPSBA(a) MODEL S9BiC100USPSAA MODEL S9B1C10OUSPSAA TYPE Upflow/Horizontal Gauge(Fired) 20 RATINGS(b) ORIFICES—Main Input BTUH 100,000 Nat.Gas Qty.—Drill Size 5-45 Capacity BTUH(ICS)(_)(d) 97,000 LP Gas Qty.—Drill Size 5-56 Temp.Rise(Min.-Max.) 40-70 GAS VALVE Redundant-One Stage AFUE(%)S9X1/S9B1(d) 96.0/92.1 PILOT SAFETY DEVICE BLOWER DRIVE DIRECT Type 120 V SiNi Igniter Diameter—Width(In.) 11 X 10 BURNERS—Type Multiport Inshot No.Used 1 Number 5 Speeds(No.)(e) 9 POWER CONN.—V/Ph/Hz(h) 120/1/60 CFM vs.in.w.g. See Fan Performance Ampacity(In Amps) 13.3 Table Motor HP 1 Max.Overcurrent Protection(Amps) 15 RPM 1075 PIPE CONN.SIZE(in.) 1/2 Volts/Ph/Hz 120/1/60 DIMENSIONS H x W x D FLA 10 Uncrated(In.) 34 x 21 x 28-3/4 COMBUSTION FAN—Type Centrifugal Crated(In.) 35-1/2 x 23 x 30-7/8 Drive—No.Speeds Direct-1 WEIGHT Motor HP—RPM 3300 Shipping(Lbs.)/Net(Lbs.) 155/145 0) Meets Energy Star Volts/Ph/Hz 120/1/60 (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 FLA 0.66 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are FILTER—Furnished? No up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. Type recommended High Velocity (0 Central Furnace heating designs are certified to ANSI Z21.47/CSA Hi Vel.(No.-Size-Thk.) 1—20x25—1 in. 2.3. (d) Based on U.S.government standard tests. VENT PIPE DIAMETER—Min(in.) 2 Round (e) 9 Speed constant torque ECM blower motor M(9) M Refer to the Vent Length Table in the Installer's Guide. HEAT EXCHANGER (9) All furnace models have a vent outlet diameterthat equals 2 in. (h) The above wiring specirications are in accordance with National Type—Fired 409 Stainless Steel Electrical Code;however,installations must comply with local codes. —Unfired 29-4C Stainless Steel S9X1 C1000-SUB-1 A-EN 3 Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SCFM 1013 847 680 514 348 Watts 104 116 129 142 155 2 SCFM 1261 1126 990 854 710 Watts 168 185 202 219 236 3 SCFM 1519 1407 1296 1184 1072 Watts 267 290 313 336 358 4 SCFM 1554 1446 1337 1229 1120 Watts 283 307 330 353 377 S9X1C10OO5PSBA 5 SCFM 1749 1651 1554 1457 1359 S9131C100USPSAA Watts 385 411 436 462 488 6 SCFM 1868 1778 1688 1599 1509 Watts 464 491 519 546 574 7 SCFM 2018 1936 1853 1770 1688 Watts 573 602 631 660 689 8 SCFM 2191 2112 2033 1954 1875 Watts 718 750 782 815 847 9 SCFM 2395 2303 2212 2120 2028 Watts 966 981 996 1012 1027 CFM Versus Temperature Rise Table 2. Heating Table— Upflow CFM VS.TEMPERATURE RISE MODEL 1100 1200 1300 1400 1500 11600 1700 1800 1900 2000 L46 2200 2300 S9X1C100U5PSBA 65 61 57 55 53 49 44 1 43 S9B1C10005PSAA 4 S9X1 C100U-SUB-1 A-EN General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the S9X1 Furnace is certified by the manufacturer to leak American Gas Association for both natural and L.P. 1%(1.4%for S9131)or less of nominal air conditioning gas. Limit setting and rating data were established and CFM delivered when pressurized to.5"water column approved under standard rating conditions using with all inlets,outlets,and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. QUICK HEATING The S-Series furnace has a special type 29-4CT"' stainless steel secondary heat exchanger to reclaim Durable,cycle tested,heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure.Low energy power vent blower,to increase efficiency and Heavy gauge steel and"wrap-around"cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside. enamel finish for strength and beauty. Every BURNERS orientation has at least two venting options.There are no knockouts on cabinet. Multiport Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot INTEGRATED SYSTEM CONTROL Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat.Complete front service access. valve,flame control and includes self diagnostics for a. Low energy power venter ease of service.Also contains dry contacts for EAC and HUM. b.Vent proving pressure switches. S9X1 C1000-SUB-1 A-E N Features and Benefits UP TO 96.0%AFUE ON S9X1 FURNACE MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections;no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Works great with larger,high-efficiency coils Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3—WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 6 SKU's— Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 5 SKU's— Downflow VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in.H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CFM/ton Blower deck has full-length rails for easy removal and REGULATORY replacement,regardless of poise All models are airtight;1%or less air leakage as per THREE—WAY MULTI-POISE(UPFLOW, ASHRAE 193(1.4%for S9B1) HORIZONTAL LEFT AND RIGHT)PLUS DEDICATED Open vestibule design provides a full 34" high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install(no conversion kits required) Widths are industry standard: 17.5",21",and 24.5" Every model has at least two venting options Depth remains approximately 28" When in horizontal,trap extends only about 2" Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as,other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup/Status/Diagnostics/Digital Display Vent table improvements including longer vent No dip switches lengths;2"pipe can be used up to 100K 6 S9X1C1000-SUB-1A-EN fn)ingersoll Rand Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Caro, Ingersoll RandID,Thermo King@ and Trane@—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. CIO)Ingersoll Rand FTc� THERMO KING 0 MWE' ingersollrand.com E14 u5 Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X1C1000-SUB-IA-EN 24Ju12019 Supersedes(New) ©2019 Ingersoll Rand Outdoor AC Unit TRANE° Submittal Split System Cooling 4TTR4048N1000A Note:"Graphics in this document are for representation only.Actual model may differ in appearance." March 2022 4TTR4048N-SUB-lA-EN 1 R n N = TECHNOLOGIES TRAME® a C SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTA ICTED. ELECTRICAL SERVICE PANEL K zs u 1 A 22.2 (118) DIA. NOLE \ LOw VOLTAGE 28.6 11-I/81 DIA. K,0- W11N 22.2 (T181 DIA. HOLE IM CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY R F J K.O. FOR ALTERNATE G ELECTRICAL ROUTING LIQUD LINE SERVICE VALVE. 'E' I.D. FEMALE BRAZE CONNECTION WITH I/4' SAE GAS LINE I/4 TURN BALL SE AVICE VALVE, 'D' FLARE PRESSURE TAP FITTINGS. I,D. FEMALE BRAZED CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H ] K 4TTR4048N 4 741 946 870 7/8 3/8 143 83 206 70 508 4WR4 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-31 (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power[dB] Model Power Level[dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR4048N 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270-2008*For reference only 2 4TTR4048 N-SUB-1 A-E N -- TRAIVE Product Specifications OUTDOOR UNIT(a)(b) 4TTR4048N1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(c) 208/230/l/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 24 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 40 W Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATUFFsn-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/l/60 selection current. (e) Use start components onlywhen compressor is found to enter locked R.L.AMPS(d)—L.R.AMPS 18.5—124 rotor condition and will not start orwhen lights dim at compressor FACTORY INSTALLED start.No means no start components.Yes means quick start kit START COMPONENTS(e) NO(Uses BAYKSKT263) components.PTC means positive temperature coefficient starter. Optional kit shown. INSULATION/SOUND BLANKET NO M Standard Air—Dry Coil—Outdoor (g) This value approximate.For more precise value see unit nameplate. COMPRESSOR HEAT NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid OUTDOOR FAN PROPELLER 60 ft.For greater length consult refrigerant piping software Pub.No. DIA.(IN.)—NO.USED 27.5—1 32-3312-0*(*denotes latest revision). TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0 IN.W.G.M 3970 NO.MOTORS—HP 1-1/5 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 208/230/l/60 F.L.AMPS 1.05 OUTDOOR COIL—TYPE SPINE FINTM ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 19.07 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 5 LBS.,3 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 7/8 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10OF DIMENSIONS H X W X D CRATED(IN.) 34.4 x 35.1 x 38.7 WEIGHT SHIPPING(LBS.) 212 NET(LBS.) 189 4TTR4048N-SU13-1 A-E N 3 TRINE' Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection.Other features include:Centrifugal unit,ten(10)feet of tested connecting line,and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match.This unit Condenser Coil is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer.The coil is protected on all four furnace coils that are AHRI certified.The unit is certified sides by louvered panels. to UL 1995.Exterior is designed for outdoor Low Ambient Cooling application. As manufactured,this system has a cooling capacity to Casing 55°F.The addition of an evaporator defrost control Unit casing is constructed of heavy gauge,galvanized permits operation to 40°F.The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish.The corner panels are prepainted.All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling(manual compressor contactor and low and high pressure and automatic change over).Sub-base to match switches.A factory supplied,field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 4TTR4048N-SUB-1 A-EN TRWE' Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. Unitary Small AC AHRI Standard 210/240 C UL US LISTED The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory. o rg. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4TTR4048N-SUB-1A-EN 28Mar2o22 Supersedes(New) ©2022 Trans k A r. ';4f .�. mmm 1rI + m 5moKe", vv 1%1�"le�' ' ti • r` r ' t Permit#: 5969 Permit Date: 05/01/24 Permit Type: COMMERCIAL MECHANICAL Project Name: Coastal Community Bank- Furnace -4Ton AC Applicant Name: D.K. Systems, Inc Applicant Address: PO Box 886 Applicant, City, State, Zip: Burlington,WA 98233 Contact: Dulce Herrera Phone: 360-755-1555 Email: dulce@dksystemsinc.com Scope of Work: Replace Like for Like (1) Furnace, and(1)Air Conditioner. Valuation: 10000.00 Square Feet: 2000 Number of Stories: 1 Construction Type: 11113 Occupancy Group: B; Business ID Code: Permit Issued: Permit Expires: Form Permit Type: COMMERCIAL MECHANICAL Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 16419 SMOKEY POINT COASTAL 611 Banking&Bank 31052800201000 BLVD COMMUNITY BANK Related Functions Contractors Contractor Primary Contact Phone Address Contractor Type License License# D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION COA 602 204 164 Street CONTRACTOR D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION L&I DKSYSI*982L1 Street CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 05/02/2024 COMMERCIAL MECHANICAL BUILDING In Review Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $176.01 Review (Table 4-1) Processing/Technology $25.00 Air Cond.Unit> 100 BTU/h Enter#of units $15.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Total $231.01 Attached Letters Date Letter Description 05/01/2024 W6 Forn-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 05/01/2024 XBP Con£ 171755102 $176.01 Outstanding Balance $55.00 Uploaded Files Date File Name 05/02/2024 20355112-20240501 BLD5969�pecs.pdf 05/02/2024 20355113-20240501 BLDS969 Apnlication.pdf 05/02/2024 20355114-20240501 BLD5969 SitcPlan.pdf CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 e INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 16419 SMOKEY POINT BLVD Permit#: 5969 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052800201000 DATE OF ISSUANCE. Scope of Work: Replace Like for Like(1)Furnace,and(1)Air Conditioner. Valuation: 10000.00 OWNER APPLICANT CONTRACTOR COASTAL COMMUNITY BANK D.K. Systems,Inc D.K. Systems,Inc 10520 19TH AVE SE PO Box 886 962 S Spruce Street EVERETT,WA 98208-4276 Burlington,WA 98233 Burlington,WA 98233 360-755-1555 360-755-1555 LIC:602 204 164 EXP:05/31/2024 LIC:DKSYSI*982L1 EXP:06/21/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST.TYPE: 11113 DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. - Guy„ 05/08/2024 Applicant Signature Date Building Official Date CONDITIONS APPROVED AS SUBMITTED.ADHERE TO THE APPROVED PLANS/DOCUMENTS.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/08/2024 Web Only-Mechanical Commercial Plan Review $176.01 05/08/2024 Processingf Technology $25.00 05/08/2024 Air Cond. Unit> 100 BTU/h $15.00 05/08/2024 Forced Air Heat<-100 BTU/h $15.00 Total Due: $231.01 Total Payment: $231.01 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 e INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 16419 SMOKEY POINT BLVD Permit#: 5969 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052800201000 DATE OF ISSUANCE. Scope of Work: Replace Like for Like(1)Furnace,and(1)Air Conditioner. Valuation: 10000.00 OWNER APPLICANT CONTRACTOR COASTAL COMMUNITY BANK D.K. Systems,Inc D.K. Systems,Inc 10520 19TH AVE SE PO Box 886 962 S Spruce Street EVERETT,WA 98208-4276 Burlington,WA 98233 Burlington,WA 98233 360-755-1555 360-755-1555 LIC:602 204 164 EXP:05/31/2024 LIC:DKSYSI*982L1 EXP:06/21/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST.TYPE: 11113 DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. D U I ce H e r re ra ga° d � , 05/08/2024 Applicant Signature a a Date Building Official Date CONDITIONS APPROVED AS SUBMITTED.ADHERE TO THE APPROVED PLANS/DOCUMENTS.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/08/2024 Web Only-Mechanical Commercial Plan Review $176.01 05/08/2024 Processingf Technology $25.00 05/08/2024 Air Cond. Unit> 100 BTU/h $15.00 05/08/2024 Forced Air Heat<-100 BTU/h $15.00 Total Due: $231.01 Total Payment: $231.01 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 5969 Permit Date: 05/01/24 Permit Type: COMMERCIAL MECHANICAL Project Name: Coastal Community Bank- Furnace -4Ton AC Applicant Name: D.K. Systems, Inc Applicant Address: PO Box 886 Applicant, City, State, Zip: Burlington,WA 98233 Contact: Dulce Herrera Phone: 360-755-1555 Email: dulce@dksystemsinc.com Scope of Work: Replace Like for Like (1) Furnace, and(1)Air Conditioner. Valuation: 10000.00 Square Feet: 2000 Number of Stories: 1 Construction Type: 11113 Occupancy Group: B; Business ID Code: Permit Issued: 05/13/2024 Permit Expires: 11/11/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning COASTAL 31052800201000 16419 SMOKEY POINT COMMUNITY 611 Banking&Bank BLUR BANK Related Functions Contractors Contractor Primary Contact Phone Address Contractor Type License License# D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION COA 602 204 164 Street CONTRACTOR D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION L&I DKSYSI*982L1 Street CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status Bank opens at 9:00.Contact R15. Steve Garber,VP Facilities/Finance-425-349- 05/15/2024 MECHANICAL 2658.Please call Steve on 05/17/2024 CED Approved FINAL the way to the appointment. Thank You. Plan Reviews Date Review Type Description Assigned To Review Status 05/02/2024 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $176.01 Review (Table 4-1) Processing/Technology $25.00 Air Cond.Unit>100 BTU/h Enter#of units $15.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Total $231.01 Attached Letters Date Letter Description 05/08/2024 Building Permit 05/01/2024 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 05/01/2024 XBP Con£ $176.01 171755102 05/06/2024 XBP Conf: $55.00 172111137 Outstanding Balance $0.00 Notes Date Note Created By: 05/10/2024 Emailed the permit for signature. Kristin Foster Uploaded Files Date File Name 05/15/2024 20696337-20240506 BLD5969 ApprovedSitPlan.pdf 05/15/2024 20696338-20240506 BLD5969 ApprovedDocuments.pdf 05/15/2024 20696326-20240513 BLD5969 IssuedPermit.pdf 05/02/2024 20355113-20240501 BLD5969 Application.pdf