HomeMy WebLinkAbout18821 CROWN RIDGE BLVD_077558_2026 INSPECTION REPORT,- 1;4 1Opermit No.:Oy—y.�S'9 Lot #: Address:/f�82/c,Pow.✓ 'Pioc6 .&4.�'.D,Contractor:Owner:.4R1-i� yW 1 Ale-W %T=Wk o Z.Date: ❑ APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION -24 hour notice required. ,4LG m k-4 ov�l6s�T�,cIG Inspector: Date: q S o 7 TYPE OF I PECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation 0 Other: �..�.,.�,��„. •`"'1�"�1'f'�•'ea+4■'r '!Mllcf:r•fir' , f l - , R -I ■� _ I , �6- N � ` or7r -W- Ql—JM, :L 04-—Ib_ NAM , I I • L �1 �._ o l i - 5 40 F f, DNG-)�'*o City of ArlingtonCommunity Development Permit Center REQUEST FOR REVIEW NAME 14-66�/.Z����6 BP #: " DATE: 9 " RETURN THIS FORM B PROJECT SUMMARY: RESPC,JDi"JG DEPP%RTIMENITS TONI C., FIRE DAVE A., BUILDING UTILITIES KERRY W., BUILDING BILL B., NATURAL RESOURCES ,' SCOTT B., BUILDING ENGINEERING Y1/0_NNE P: PL_/-%,NNING SHERRI PHELPS, BUS LIC CWA., CONSULTANT DERYL T., MARYSVILLE UTIL JIM T., CONSULTANT SUBMITTAL INFORMATION IS ATTACHED. Please review the information and return this form and your comments in memo form to the Permit Center. If you have no comments, please return the form with the "Okay to Issue" box checked. PLEASE MARK ONE BOX, SIGN, DATE, AND RETURN THIS FORM TO THE PERMIT CENTER. ❑ COMMENTS FOR THIS REVIEW ARE IN THE ATTACHED MEMO %C NO COMMENT FOR THIS REVIEW, OKAY TO ISSUE PERMIT ❑ COMMENTS REVIEWED BY DATE -�'�� Y O f, City of Arlington UNG CommUnity Development Permit Center REQUEST FOR REVIEW NAME: DATE: RETURN THIS FORM BY: PROJECT SUMMARY: '000,- 1 �RESPOINIDING "El"RT1ViEINTS TOM C., FIRE -- DAVE A., BUILDING UTILITIES KERRY W., BUILDING BILL B., NATURAL RESOURCES SCOTT B., BUILDING ENGINEERING YVONNE P., PLANNING SHERRI PHELPS, BUS LIC DERYL T., MARYSVILLE UTIL RECEIVED C�vA., CONSULTANT JIM T., CONSULTANT SUBMITTAL INFORMATION IS ATTACHED. Please review the information and return this forma and comments in memo form to the Permit Center. If'y-°Q-heee'TTTcomments, please return the form with he "Okay to Issue" box checked. PLEASE MARK ONE BOX, SIGN, DATE, AND RETURN THIS FORM TO THE PERMIT CENTER. COMMENTS FOR THIS REVIEW ARE IN THE ATTACHED MEMO NO COMMENT FOR THIS REVIEW, OKAY TO ISSUE PERMIT COMMENTS y REVIEWED BY �`' ---DATE- w r ti/Em Fire & /l simplexGrinnel! LETTER OF TRANSMITTAL c:curity 9520 10th Avenue South,Suite 100 Seattle, WA 98108 DATE: 8/29/2007 JOB NO. 930615510 Tel. Line: (206)291-1400 ATTN. Fire Alarm Permits FAX Line: (206)291-1500 RE: Arlington High School-Portable Addition Contractor's License SIMPLL'988BG TO: City of Arlington, Dept. of Comm. Develop. 238 N Olympic Ave. Arlington, WA 98223 Phone: 360403-3551 WE ARE SENDING YOU 0 Attached ❑Under separate cover via the following items: ❑� Shop Drawings ❑Prints ❑Samples ❑� Cut Sheets ❑Copy of letter ❑Change Order ❑� Other COPIES DATE NO. DESCRIPTION 4 8/28/2007 Sets Fire alarm drawings for the above job. 4 8/28/2007 Sets Data/spec sheet submittals for the fire alarm system on the above job. 1 8/29/2007 Original Application for a fire alarm permit for the above job. THESE ARE TRANSMITTED as checked below: For Approval ❑Resubmit copies for approval. 0 For Your Use ❑For Approval copies for distribution. ❑As Requested Q Return 1 or 2 corrected plans. For Review and Comment REMARKS Please accept the enclosed documents so that we may obtain afire alarm permit in Rodger's Electric's _ name as they are the ones that are actually doing the pulling the wire and installing the fire alarm devices. Simplex- Grinnell did the drawings and will provide the actual devices. If you have any questions at all, please let me know at the number below right. Once this is approved and ready to pick up/issue, please let me know how much we owe you and I will request a check from our corporate office. Thank you very much for your help. COPY TO: File, Ship FedEx SIGNED: KGlthi O'rzenr, 200 291-1402 IF ENCLOSURES ARE NOT AS NOTED, KINDLY NOTIFY US AT ONCE 0,"-INC'�" FIRE ALARM PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3551 • FAX(360)403 3447 THIS APPLACATION MUST BE ACCOMPANIED BY FOUR(4)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) (p) New Fire Alarm ('Fire Alarm Alteration/Addition Project Address:- I $-9 2 1"U'1 Caw n �g p� ��V� ' Parcel ID#: Number of Zones/Panels: Building Area (Sq Ft): I DD Valuation: Owner:_(-)YU ng1wn t)�,6r 31� n/ Phone Number: Address: �_, Fit*t>^,Qn /-yb City: Ar h'v-V State: Zip Code: � 22 Contact Person: V\athu 0,Rt_6r Phone Number: ULP 'M1'Iqb$ Cetr Phone: 1,4ob Fax: S 07D E-mail: KD Address: 'ZD 0Ayt +''100 City: -Q-AA fLe-• Stater Zip Code: ? v 6 - r Contractor: � 0418exe, El eclyi c" C­ (46. Phone Number: `f u'I ?�'✓2 ZID� Address: 4.011 F_ t l LV- ae, vie j D?- City: FV WA j tY State: Zip Code: Contractor's License Number: d D LZ E,6— C- :�_ PA l p Expiration: Electrical Contractor: Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. }�a4k y F w C�vt>�1 �b 2�-o j11B RECEIVF Applicants gnature Date S;�,P �C�t{[�i ct►� AUCQ01s Zoffl Print Applicants Name Y: FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form-22 Page 1 of 1 3/07 dwa _-�: f' tgco Fire & Security Simp/exGrinne// O Building Systems Submittal Package Arlington High School 18821 Crown Ridge Blvd Arlington, WA 98223 Portable Addition Fire Alarm System SimplexGrinnell LP 9520 10th Ave. South Rodgers Electric Co., Inc. Suite 100 1161 E. Marine View Drive Seattle, WA 98108 Everett, WA 98201 Phone: (206)291-1400 Phone: (425) 252-2107 Fax: (206) 291-1500 FAX: (425) 252-2114 www.SimplexGrinnell.com Fire,Security,communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle cities throughout the World tyco Fire& Security Simp/exGrinne// Table of Contents Section I: Scheduling/Installation Checklist Section II: Equipment List & Equipment Datasheets Section III: Hardware Warranty Section IV: Manufacturer's Recommendation Section V: Testing Procedure for Devices Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World tyco Fire& Security Simp/exGrinneH Scheduling We would like to take this opportunity to introduce you to Carey Lambeth. He/She will be the SimplexGrinnell Project Manager assigned to this project. The Project Manager has the full responsibility and authority over this project. Only the Project,Manager can commit or change delivgrxdates,order materials, and schedule field personnel. Please direct all of your correspondence, questions and construction needs to this person. Carey Lambeth can be reached at the following Office: (206)291-1400 Fax: (206)291-1500 Email: clambeth@tycoint.com In an effort to assist you in your installation we require you to arrange a Pre-Construction meeting with one of our Technicians. This meeting will allow your field foreman to ask any questions they may have in regards to the installation of your system. Based on the equipment quantities and current scope of work our Technician will need no less than 1.00business days to complete all necessary programming and commissioning from the time the below checklist is complete prior to any AHJ testing. Please make sure this time is allowed for in the General Construction CPM schedule as it can not be compressed. Change orders,change of scope, etc. may require additional time allotment to field personnel. Installation Checklist SimplexGrinnell is committed to providing the highest quality service available. As part of this service we want to ensure that the installation results in a trouble-free system. Please review the Checklist below and ensure each item is complete prior to our site visit. A Technician will be dispatched only after the below checklist items have been completed. If these items are not completed prior to the visit by our technician,you may incur additional charges not covered by our quotation. Please feel free to contact our office if you have any questions. O Fire Alarm Panel(s) have been mounted and all wiring(power, MAPNET,signal, door-holders, etc.) pulled into panel(s). O All wiring pulled into panel(s)or junction boxes have been permanently marked with wire markers and can easily be identified by a SimplexGrinnell Technician. O System Power is supplied and on a dedicated circuit(Do Not Energize prior to Technician visit). O All peripheral devices have been mounted(Smoke Detectors still covered). O All end-of-line resistors have been installed. O All alarm initiating circuits(smoke detectors, pull stations, etc.) have been checked for shorts, opens and grounds. O All alarm notification circuits(speakers, horns,strobes, etc.)have been checked for shorts,opens and grounds. O All remaining wiring (door-holders, FACP 24VDC, etc.) has been checked. O Flows,Tampers, and Pressure Switches installed,properly wired and adjusted. O All devices are properly protected against construction dust and contamination. O Contact us immediately if there is no digital dialer or system monitoring provisions already in place. The dialer, phone lines and service will be required for system testing. O There are no missing parts or equipment. Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World tyco Fire& Security Simp/exGrinne// Equipment List & Equipment Datasheets Fire Alarm System Quantity Product ID Product Description 1 4009-9201 IDNET NAC Panel 2 2081-9272 6.2AH Battery 1 4090-9116 IDNET Isolation Module 2 4099-9001 Manual Station 3 4098-9714 Photoelectric Smoke Sensor 2 4098-9733 Heat Sensor 5 4098-9792 Sensor Base 2 4906-9130 Multi-Candela Ceiling Horn/Strobe 1 4905-9815 Smart-synch Adapter Module 1 ASWP-2475W-FR Weatherproof Horn/Strobe 1 WPBB-R Weatherproof Backbox Equipment List subject to change. Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World U®Simplex LifeAlarili,lb Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved, 4009 IDNetTM NAC Extender for Control from 4010 or MEA (NYC)Acceptance* 41000 IDNet Communications; or from Conventional NACs Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Up to 8 NACs _ Four, Class B (Style Y) NACs are standard: • Rated 2 A each for conventional reverse polarity 4009 IDNet -- 24—VDC-notification-appliances-and providing NAC Extender — — multiple operation modes • Can be selected to provide synchronization for Simplex visible notification strobe flashes Optional IDNet • Capable of controlling TrueAlerto non-addressable Channel Repeater notification appliances operating with SmartSyncTM � two-wire control mode** Input control options: IDNet addressable communications from a Simplex 2-Wire IDNet C �% • P Communications � model 4010 or 410OU Fire Alarm Control Panel** I Fiber Optic IDNet � • Or from one or two conventional 24 VDC NACs with I Communications ac multiple output control options __ NAC Control IDNet communications control benefits: -' • Provides status monitoring and individual NAC control ® IDNet Fiber using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet"Device Level"earth fault location 4010(shown)or WALKTESTTm operation is available with either 41000 Fire Alarm input choice Control Panel Internal 8 A power supply/battery charger: Fire Alarm Control Panel with Conventional NACs • Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet • Provides status monitoring of battery,input power, and 4009 IDNet NAC Extender Connection Reference Drawing earth faults MWIRM • Rated 8 A for"Special Application' appliances; including Simplex 4901,4903,4904, and 4906 Series ADA Compliance.Complying with the notification horns, strobes,horn/strobes, and speaker/strobes requirements of ADA(Americans-with Disabilities Act) • Rated 6 A for"Regulated 24 DC"appliance power may require more notification appliance power than is Optional 4009 IDNet NAC Extender modules: available within the fire alarm control panel. When additional power is required,a Simplex 4009 IDNet NAC • IDNet Communications Repeater provides Class B Extender can provide up to 8 A of NAC power with up to (Style 4) or Class A(Style 6)output eight, supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility.The 4009 IDNet NAC Extender available as Class B or Class A can be mounted close to a compatible dedicated host • Four additional Class B NACs,rated 1.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A(Style Z),Two Circuit Adapter Module Additional Information.For additional operation detail UL Listed to Standard 864 and application information,refer to Installation Instructions 574-181 and field wiring diagram 842-068. ULC listed model is 4009-9202CA.This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. IDNet communication fiber optic transmitters: See CSFM Listing 7300.0026:214 for albwable values and/or conditions concerning • For applications requiring the data integrity available material presented in this document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New York Department of Buildings—MEA35.93E. with fiber optic communications Additional listings may be applicable;contact your local Simplex product supplier for the • Available as Class B (Style 4) or Class A(Style 7) latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. • Mounts in standard six-gang electrical box SmartSync hom/strobe operation is protected under U.S.Patent No.6,281,789.IDNet External batter cabinet for 18 Ah batteries addressable communications are protecled under U.S.Patent Nos.4,796,025; y 5,966,002;and 6,034,601.41000 requires revision 11 software or higher for t Simplex WALKTEST service tesling is protected under U.S.Patent No.4,725.818. compatibility.4010 requires revision 2 software or higher for compatibility. S4009-0002-4 2/2006 . . • . - � Hardwire Conti applications.For applications where an existing (or new)conventional NAC needs IDNet Addressable Communications Compatible. additional power, the 4009 IDNet NAC Extender can be Up to five, 4009 IDNet NAC Extenders can be controlled controlled directly from the NAC.Either one or two on a single IDNet communications channel. Each output NACs, from either the same, or from different host fire NAC can be individually controlled for general alarm or alarm control panels,can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs. Multiple control address per Extender. Individual Extender NACs can also selections provide flexible operation. (Refer to page 4 for be manually controlled from the host panel. IDNet more detail.)Alarms from the host panel will activate the controlled extenders will inform the host panel of troubles four,4009 IDNet NAC Extender NACs(or optionally, via IDNet communications. eight NACs) to extend the alarm. Optional IDNet Repeaters. IDNet communications The 4009 IDNet Extender monitors itself and each of its can be repeated with the optional IDNct Repeater Module output NACs for trouble conditions, including earth --or-with-the-optional-Fiber-Optic-Receiver Module. Up to - -- -— - faults. Extenders wired to conventional NACs will 100 of the IDNet channel points can be repeated once indicate a trouble by opening the path to the NAC's (refer to pages 3 and 5 for details).Repeated IDNet end-of-line resistor,but retaining the ability to respond to communications also support the device level earth alarms. Individual troubles are also annunciated by LEDs fault location utility of the host panel. located on the 4009 IDNet NAC Extender main circuit board. (Refer to page 7 for more diagnostic information.) Standard Models Model Description 4009-9201 120 VAC input 4009-9202CA' 4009 IDNet NAC Extender with 4, Class B(Style Y) NACs and 8 A power supply 4009-9301 240 VAC in ut ULC listed model Optional Modules (for on-site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B(Style Y), 4009-9808 Dual Class A(Style Z adapter for two NAC outputs) Select as required 4 maximum 4009-9809 IDNet Repeater, output is Class A(Style 6) or Class B(Style 4) Select either all IDNel Repeater or a 4009-9810 Fiber Optic Receiver Class B (Style 4 Fiber Optic Receiver as required 4009-9811 Class A(Style 7 fiber,Style 6 IDNet 4009-9805 Red Appliqu6 for door Select if required 2975-9801 Semi-Flush Trim Kit Beige trim 1-7/16"wide(78 mm), use if required for 2975-9802 1 Red trim semi-flush installations Battery Selection (select battery size per system requirements) Model Description Comments 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC Two batteries are required, 24 VDC operation 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet, two batteries are required, 24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090-9105 IDNet Fiber Optic Class B (Style 4 operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class A(Style 7 operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4"W x 13-1/2" H x 5-3/4"D _ 413 mm x 343 mm x 146 mm) 4081 Series End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details 2 S4009-0002-4 2/2006 Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements,some wiring is not shown.) IDNet addressable communications channel, f shown Class B(Style 4) Output NACs,four standard, Conventional NAC operation(horns) eight with expansion option Select conventional or SmartSync MUSEUMoperation per NAC 41000(shown)or 4010 Fire W Alarm Control Panel Ic! SmartSync operation(horns and strobes) 4009 IDNet NAC Extender with — optional internal IDNet Repeater ` Conventional NAC „�. operation(strobes) Rr_ emoted IDNet Channel: �� IIIIIIIIIII up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five (5)4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once(can pass throuqh only one series connected repeater or one fiber optic receiver). • •- • • • • Two fiber cables,3000 ft Output NACs 4090-9105,Class B (914 m)maximum distance (Style 4)Output Fiber - - - IIIItItiI111RtNIItlIfliNIINOfliW1111111WflW Optic Transmitter I IDNet addressable communications channel Class B(Style 4)or Class A (Style 6),Class B shown Repoated IDNet Channel:up to 100 devices maximum on repeater output,250 devices total on IDNet Channel IIIIIIIINiIIIlIIINNINIII1111tNIIIIII11NilIfliWN Four fiber cables,3000 ft 4010 or 41000 Fire (914 m)maximum distance Alarm Control Panel u 24 VDC power for fiber optic transmitters 4090-9107,Class A(Style 7) Output Fiber Optic Transmitter • 4009 IDNet NAC Extenders with optional' Output NACs internal IDNet Fiber Receivers NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009-0002-4 2/2006 • - • • • • • • • • • e • • NAC Input Selections. The 4009 IDNet NAC The TrueAlert Notification Appliance product line Extender can be selected to: includes addressable and non-addressable operation. • Track input NAC operation or to provide a locally Nuii-addressable inudels are available with 2-wire generated code, selectable per NAC input SmartSync operation or conventional 4-wire operation. • If selected for local coding, NAC outputs can be either The following details apply to use with the 4009 IDNet Temporal Coded or 60 Beats/min March Time Coded, NAC Extender: one code selection per extender(input NACs must be on • TtueAleit nun-addressable models with SmartSync continuous with Alarm) operation allow audible notification to be separately • Additionally, NAC outputs can be selected to provide controlled over the same wire pair that controls visible notification(protected under U.S. Patent No. the Simplex Strobe synchronization signal. This signal visible o will synchronize the flashes of synchronized strobes but • 4009,73Net NAC--Extenders can-be-selected selected to provide will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet (Strobes are for operation by noncoded NACs) communications or conventional NACs NAC input to NAC output control can be selected for • IDNet control allows output NACs to be individually standard and optional NACs per the following table: selected for conventional or SmartSync operation Conventional NAC Output Op eration Options • With NAC input control, all output NACs are selected Input A B C for either conventional or SmartSync operation • Class A(Style Z) SmartSync operation requires NAC 1 NACs 1 &2.5&6 NACs 1-4 NACs 1 8 SmartSync Control Module (SCM)4905-9938 (refer to NAC 2 NACs 3&4.7&8 NACs 5 8 None data sheet S4905-0003 for details) SmartSync NAC Output Operation • Refer to data sheet S4009-0003 for TrueAlert Input NAC Control Function addressable operation details,contact your local Simplex NAC 1 Strobe Control All NAC outputs(1-8) product supplier for further information on specific NAC 2 1 torn Control 1 TrueAlert notification appliances Hardwire • •l NAC Connection • Diaciram Up to eight(8)output NACs total;hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 o ut 1) (see Note 1) • 11 �lConventional NACs,,,,, ��7 With hardwire control, I, NAC outputs are all Output conventional or all "———— ———_ ' NACs SmartSync operation ® I scM t 4009 IDNet NAC I Extender Fire Alarm Control Panel I with Conventional NACs SmartSync operation I I 4905-9938 SmartSync Control Module is required NAC 2 input for Class A output wiring of SmartSync NACs (optional,see Note 1) I To additional 4009 IDNet NAC Extenders(up to four(4), �----- 4009 IDNet NAC Extenders per NAC);see Note 2 Notes: 1.For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required. NAC 1 is"on-until-reset"and NAC 2 is"on-until-silenced." 2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe output from a Synchronized Flash Module(4905-9914 for Class B operation,4905-9922 for Class A operation)or, if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 4 S4009-0002-4 2/2006 120 VAC Input 4009-9201 3A @ 102-132 VAC 60 Hz Input 240 VAC Input 4009-9301 1.5A @ 204-264 VAC 50/60 Hz Ratings Hardwire Control from External Conventional reverse polarity operation NACs, Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating 8 A,Special Application appliances 6 A, Regulated 24 DC appliance power Standard NACs 2 A each,Special Application or Regulated 24 DC appliance power Optional NACs 1.5 A each,Special Application appliances (requires 4009-9807) 1 A each, Regulated 24 DC appliance power S eolal A lication Simplex 4901,4903,4904,and 4906 Series horns,strobes, and combination Output Ratings P-- pp horn/strobes and speaker/strobes(contact your Simplex product representative Appliances for compatible appliances) Regulated 24 DC Power for other appliances listed to UL Standard 1971 or UL Standard 464; use Appliances associated external synchronization modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized;output NACs configured for Simplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA @ 24 VDC system supplied IDNet Input, One Address Maximum distance from IDNet source is 2500 ft 762 m IDNet Repeater Repeated IDNet output for up to 100 devices(total IDNet devices not to exceed Module 250 per channel (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft 762 m Total distance including"T-taps"is 10,000 it 3048 m Class A(Style 6 loop maximum distance is 2500 ft 762 m no"T'to s Fiber Optic Receiver Modules Input Current 4009-9810, Class B (Style 4), 65 mA @ 24 VDC system supplied 4009-9811, Class A(Style 7), 80 mA ® 24 VDC,system supplied IDNet Output Specifications Same as those for Repeater Module see above Fiber Optic Transmission Distance 3000 ft 914 m maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Op erating Temperature 32°to 120° F 0°to 49"C Operating Humidity Range 10%to 90%RH from 32' F to 104"F 0°C to 40°C Wiring Connections' Terminal blocks for 18 AWG stranded to 12 AWG solid • - • . •- • Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B(Style 4). 30 mA ® 24 VDC 4090-9107, Class A(Style 7), 35 mA @ 24 VDC Multimode,graded index, 50/125 m, 62.5/125 pm, 100/40 pm, or 200 pm Fiber Optic Connections and cable Type ST connectors requirements 4090-9105, Class B(Style 4 operation,two fiber cables required 4090-9107, Class A(Style 6)operation.four fiber cables reouired Module Size with mounting bracket 6-13116"W x 3-3/4"H x 1-1/8"D 173 mm x 95 mm x 29 mm Green LED flashing=transmit On-board Status Indicators Red LED flashing=receive Separate red LED on 4090-9107=Class A(Stvle 7) receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft 914 m maximum Wiring Connections' Terminal blocks for 18 AWG stranded to 12 AWG solid Operating Humidity 10%to 90% RH from 32'to 104" F 0°to 401 C Operating Temperature 32°F to 120°F 0°to 49'C Metric wire equivalents: 18 AWG=0.82 mm2; 12 AWG=3.31 mm2 5 S4009-0002-4 2/2006 • - • • •• • �� 16-1/4"(413 mm) Cabinet depth (108 mm)� 10-29/32"(277 mm) Door,5/8" ® 0 o o (16 mm)thick O O Optional Class A 4009-9807 Additional Four 13-1/2" adapter modules point module(shown with (343 mm) ® Class A adapters) Exposed cabinet _ dimension for _ j� System Module semi-flush mount lL�ID1J 1"(25.4 mm), ; Knockouts for screw IDNet repeater or 1-3/8"(35 mm)with or nail mounting holes Fiber optic receiver semi-flush trim 0 I � 12"(305 mm) o Battery location,no conduit entry or wiring in—� I this area(12.7 Ah battery outline shown) O O Semi-flush trim option Non-power limited wiring area(AC input) 1-3/16"wide(30 mm), 3/8"(9.5 mm)thick Wall surface reference for semi-flush mount, NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locatinq conduit entrance. Optional red applique (4009-9805) 411• 1EXTENDER 6 S4009-0002-4 2/2006 � 1 • 1 1 1 ti • - ' • • • Surface mount box: _� 0 0 0 0 0 0 Simplex model 2975-9217 (ordered separately) Fn n n n n Flush mount masonry box: a <:=> C==> <=> <:Z=:> use 6-gang box, RACO#960,2-1/2"deep `► 0 0 0 0 0 0 (64 mm), or RACO#965,3-1/2" (89 mm) 0 deep,or equal(supplied by others) ,0 0 0 Flush mount ganged boxes: _ use 6-gang box, 1-1/2"(38 mm) minimum depth;six, RACO#400 or equal,(supplied by others) O 0 O O O 0 0 0 0 0 o IDNet fiber optic transmitter: 4090-9107,Shown,Class A(Style 7)output 4090-9105, Not shown,Class B(Style 4)output INSTALLATION NOTE: Fiber optic cable bend radius should be 2"(51 mm) minimum,or per Manufacturer's specification. 0 0 0 0 0 0 Six-gang blank cover plate Mulberry Metal Products 97156 or equal(by others) Power-up Self-Diagnostics.Upon power-up,the LED Status Indicators are provided for the following: 4009 IDNet NAC Extender tests each module and • Each NAC(standard and optional)has a dedicated performs earth fault diagnostics. Trouble conditions are yellow LED that: communicated to the host control panel and are also — During supervision provides a slow flash to indicate displayed on diagnostic status LEDs in the 4009 IDNet a short circuit condition and a fast flash to indicate NAC Extender. When connected via IDNet an open circuit communications,detailed status information is available at the host.When controlled with conventional NAC — During an alarm, the LED follows the NAC output inputs,common troubles are signaled by providing a (on steady or flashing with coded output) polarized open circuit that disconnects the NAC wiring • Four, general status yellow LEDs provide nine from its end-of-line resistor but still allows a reversed separate indications listed in priority of urgency.As a polarity alarm to be received. trouble is eliminated, any remaining trouble(s)will Door Mounted Reference Label.The 4009 IDNet then be indicated until the 4009 IDNet NAC Extender NAC Extender has a detailed programming and is returned to normal operation. diagnostic label inside the front door that provides a quick • AC power status is indicated by a green LED that is reference for both installation and checkout. on when AC is normal. During low AC(brownout) conditions or with no AC,the LED is off.Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-4 2/2006 11 • � - bMa IN777dl Panel Module Selection (shaded model numbers are optional modules) Model Description Suaervisory Actual p Current Supervisory Alarm Current Actual Alarm 4009-9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009-9301 240 VAC input 4009-9807 Additional Four Point NAC 40 mA + +NAC loads +NAC loads (add below) (add below) 4009-9808 Dual Class A Adapter(current included in basic panel value) __4IIOS- =' ]DNefRepeater- - 70 mA 70 mA f 4009.9810"t Fiber Optic Receiver, Class B 65 mA + 65 mA + 4009-9811•f 1 Fiber Optic Receiver, Class A 80 mA 80 mA IDNet devices, 0.7 mA each, maximum of 100 1 otal devices + Total devices (Al) + (see note 5) x 0.7 mA each x 0.7 mA each Auxiliary Power Output, calculate per total 500 mA + 500 mA (A2) + device requirements (see note 5) maximum maximum Total Supervisory Current= (A) + Total 4009 IDNet NAC Extender Panel Alarm Current= (BI) "Only one of these three modules can be chosen for a single 4009 IDNet NAC Extender. t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. NAC Loads NAC Type NAC Circuit# NAC Alarm Current Circuit 1 + Standard Panel NACS, 2 A maximum per NAC (see note 5) Circuit 2 + Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1.5 A maximum per NAC (see note 5) Circuit 6 + Circuit 7 + Circuit 8 + Total NAC Loads Alarm Current= _(C) Total 4009 IDNet NAC Extender Panel Alarm Current(enter B1 from above) = (132) + Procedure- Total Alarm Current= (D) 1. Calculate total panel supervisory current (A). 2. Calculate total panel alarm current (131) [convert mA to A, example: 350 mA=0.35 A]. Copy(131) into block(132). 3. Calculate total NAC loads alarm current from notification appliance ratings(C). 4. Add (C) + (132)to determine total alarm current(D). 5. Total of IDNet Device Current (Al) +Auxiliary Power Output Current (A2) + NAC Loads Alarm Current (C) is 8 A maximum. 6. Refer to Simplex battery selection document 900-012 for recommended battery size for specific standby requirements (i.e. 24 hours supervisory, 5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah. Tyco,Simplex,the Simplex logo,LifeAlarm,IDNet,WALKTEST,SmanSync,and TrueAlert are trademarks of Tyco International AC or its affiliates in the U.S.and/or other countries. u®simpim Tyco Safety Products Westminster•Westminster,MA•01441-0001 •USA S4009-0002-4 2/2006 www.tycosafetyproducts-usa-wm.com ©2006 Tyco Safety-Products Westminster.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice 0,,Simplex 41001V Addressable Peripherals UL, ULC Listed, 4090-9116 Addressable IDNetTA° Isolator CSFM Approved* For 41000 Series Fire Alarm Controls ® 0 no o Dual port, bi-directional communications isolator for use with Simplex 41000 Series fire alarm control panel IDNet**Signaling Line Circuits (SLCs): • Either port can serve as an input or output,ports are automatically separated when a communications short ® ;- circuit occurs ro 11 IOSJGL:7 • Isolation can also be activated from the 410OU control M panel for system diagnostics o o Earth fault isolation reduces time to fix wiring problems: • Built-in control panel diagnostics assist in locating 4090-9116 Isolator for 41000 Series IDNet earth fault conditions—the most common installation Communications(shown approximately 1/2 size) wiring problem �- Small size fits into 4"square electrical box and Model Description allows convenient mounting where protection is,,,;O, 4090-9116 Addressable IDNet Isolator for41000 Systems required For Class B (Style 4)or Class A(Style 6)wiring: 4090-9801 For semi-flush Optional trim plate with LED viewing mounted box • Communications are monitored from either port window,includes mounting screws For surface • 4090 9802 Class A wired SLCs can optimize operation by mounted box maintaining communications with devices outside of the isolated wiring section Mm nOT-1 UL listed to Standard 864 Electrical - . . Communications 41000 IDNet,1 address Power Consumes one unit load,power supplied form The 4090-9116 IDNet communications isolator provides 41000 IDNet communications isolation to improve installation Screw terminals for input and output wiring, convenience and increase system integrity.Mounting Wire Connections 18 to 14 AWG wire(0.82 mm2 to 2.08 mm2) requires a standard 4-inch square electrical box,allowing Wiring Distances the isolator to be conveniently installed where protection Up to 2500 ft(762 m)from fire alarm is most likely to be desired. control panel Short Circuit Isolation.An-internal isolation relay IDNet Wiring Up to 10,000 ft(3048 m)total wiring distance allows a compatible fire.alak h'control panel to separate Reference (including T-Taps) shorted communications wiring from functioning wiring Compatible with Simplex 2081-9044 to optimize the available sensors or other IDNet Overvoltage Protectors addressable devices.The isolator's status is Mechanical communicated to the control panel,allowing it to assist in 4-1/8"H x 4-1/8"W x 1-3/8"D identifying the location of the shorted wiring.When Dimensions (105 mm x 105 mm x 35 mm) visible by using the optional trim plates,a pulsing status Black thermoplastic housing on LED indicates communications polling status and then Package metal mounting plate becomes steady on when the isolator is in isolation mode. Temperature 32°to 120°F(0°to 49°C)indoor operation only Earth Faults.During installation,earth faults frequently Humidity Range 10 to 90%RH at 90'F(32°C) occur.Finding these faults normally requires extensive wiring disconnection.With the 4090-9116,earth faults on the IDNet communications lines can be quickly located to ' This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144 1 of the California Health and Safety Code.See CSFM Listing assist in their repair and to restore the system wiring to 7300-0026:252 for allowable values and/or conditions concerning material presented in normal. this document.It is subject to re-examination,revision,and possible cancellation.This product was not FM or MEA(NYC)approved as of document revision date.Additional "IDNet addressable communications designs are protected by U.S.Patent No 4,796,025. listings may be applicable;contact your local Simplex product supplier for the latest Refer to specific devices and control panels to ensure compatibility status. S4090-0005-1 1/02 . . MM Short Circuit Isolation.The one-line diagram on this Earth Fault Isolation.In the event of an earth fault, page shows a multiple floor example with Class B each floor can be individually isolated using built-in (Style 4)IDNet communications for each floor starting at 4100U control panel diagnostics. With individual floor an Isolator. (A sensor in the 4098-9793 Isolator Base is control,the earth fault can be isolated to the floor level to shown for reference as an alternate isolating device.)If narrow the search area.By adding more isolators,the floor wiring beyond the isolator should experience a short section required to be isolated can be reduced,allowing circuit,each floor is automatically separated from the more devices to remain active. next,preventing the short circuit from disabling the entire IDNet communications wiring. Fourth floor J_ --T Third floor Isolator base (see note 4) — — — — — — — — — — — — — — — — — — — — — — — — Second floor — — — — — — — — — — — — — — — — — — — — — — — First floor U 41000,IDNetcommunications,— 9 wira(see wiring notes) Class B riser 4090-9116 Addressable IDNet Isolator IDNet Compatible TrueAlarm sensor and base i ❑ Any IDNet device(addressable station,ZAM,IAM,etc.) � ®� I I•r i f��R u�rs,t:�i Wiring Notes: 1.Operation of the 4090-9116 Addressable IDNet Isolator requires i connection to a 4100U IDNet communications channel. 2.This is a one-line drawing showing only IDNet communications Simplex 4100U Series wiring. Fire Control Panel 3.Some IDNet devices require additional wiring for power. Refer to specific devices for details. 4. IDNet communications isolation are also available using the 4098-9793 IDNet Isolator base.Refer to data sheet S4098-0025 for information. 2 S4090-0005-1 1102 Class A Wiring.The illustration below is a modification Diagnostic Assistance.It is recommended that for of Example 1.Each floor is wired as a Class A(Style 6) Class A wiring,isolators be located as the first and last connection,and a sensor mounted in a 4098-9793 Isolator devices in the loop(as shown below).With the resulting Base has been added for reference.This illustrates that wiring isolation flexibility,locating earth wiring faults with additional isolators(either the 4090-9116 or the can be made easier. isolator base),there is a reduction in the number isolated devices in the event of a short circuit. Isolator bases Last device (see note 5) _ I I I Fourth floor ; - - - - - - - - - - -1- - - - - - - - - - - - - - 1 I 1 I 1� 1 I 1 1 1 1 1 Third floor —1— — — — — — — — — — — — — — I I I I 1 , 1 I 1 a 1 I I I Second floor ; — — — — — — — — �— — —;— — — — — — — — — — — — — — I I 1 1 I 1 I 1 1 1 1 First device First floor 41000,IDNet communications, 2 wire(see wiring notes) 4090-9116 Addressable IDNet Isolator Class A Cu R, IDNet Circuit ® IDNet Compatible TrueAlarm sensor and base �-- ❑ Any IDNet device(addressable station,ZAM,IAM,etc.) Wiring Notes: • 1.Operation of the 4090-9116 Addressable IDNet Isolator requires connection to a 4100U IDNet communications channel. 2.This is a one-line drawing showing only IDNet communications Wiring. 3.Some IDNet devices require additional wiring for power.Refer to specific devices for details. Simplex 4100U Series 4.When wiring for Class A IDNet communications,connecting an Fire Alarm Control Isolator as the first and the last device is recommended to assist with earth fault control panel diagnostics. 5.IDNet communications isolation are also available using the 4098-9793 IDNet Isolator base.Refer to data sheet S4098-0025 for information. 3 S4090-0005-1 1/02 n nO \l Address setting under O resealable 0 " n 4"(102 mm)square box,2-1/8" (54 mm)minimum depth, RACO 232 or equal(supplied by others) »�pirox M ` Status LED 4090-9116 Addressable ® �\Label front view IDNet Isolator ® Double gang blank cover plate and mounting screws,for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate (4-9/16") Light pipe for LED viewing (109�m 116 mm ) IF 4-9/16"(116 mrn) ; 4-5/16"(109 mm) 4090-9801,Trim plate for 4090-9802,Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED Tyco,Simplex,the Simplex logo,TrueAlorm,and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S.and/or other countries. f3 Simplex Westminster,Massachusetts 01441-0001 USA www.simplexnetcom S4090-0005-1 1/02 ©2002 Simplex Time Recorder Co DBA TEPG-US(a Tyco company).All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice U®Simplex Multi-Application Peripherals UL, ULC Listed,FM, CSFM, MAPNET II®or IDNetTM Communicating Devices and MEA (NYC)Approved* Addressable Manual Stations Individually addressable manual fire alarm stations with: • Power and data supplied via MAPNET II or IDNet M ■ addressable communications using a single wire PULL DOWN ! pair** • Operation that complies with ADA requirements j tea • Pull lever that protrudes when alarmed • Break-rod supplied(use is optional) • Models are available with single or double action (breakglass or push)operation 4099-9001 Addressable Manual Station • UL listed to Standard 38 (front and side view) Compatible with the following Simplex®control panels: • Model Series 4010/4100/4100U/4120/4020 fire alarm 7EAK 'LASS PUSH control panels equipped with either IDNet or PULL DcwN PULL DOWN MAPNET II communicationsKEY • Model Series 2120 communicating device , ONLY transponders(CDTs)equipped with MAPNET II communications Compact construction: 4099-9002 4099-9003 With 2099-9828 • Electronics module enclosure minimizes dust Breakglass Push Institutional infiltration Cover kit • Allows mounting in standard electrical boxes ' • Screw terminals for wiring connections Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the Tamper resistant reset key lock(keyed same as alarm switch.Completing the action breaks an internal Simplex fire alarm cabinets) plastic break-rod(visible below the pull lever,use is Multiple mounting options: optional).The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull • Surface or semi-flush with standard boxes or requirements needed for easy activation.The pull lever matching Simplex boxes latches into the alarm position and remains extended out • Flush mount adapter kit of the housing to provide a visible indication. • Adapters are available for retrofitting to commonly Double Action Stations(Breakglass)require the available existing boxes operator to strike the front mounted hammer to break the glass and expose the recessed pull lever.The pull lever then operates as a single action station. The Simplex model 4099-9001 addressable station Double Action Stations (Push Type)require that a combines the familiar Simplex manual station housing spring loaded interference plate(marked PUSH)be with a compact communication module that is easily pushed back to access the pull lever of the single action installed to satisfy demanding applications.Its integral station. individual addressable module(IAM)constantly monitors Station reset requires the use of a key to reset the status and communicates changes to the connected control manual station lever and deactivate the alarm switch. (If panel via MAPNET II or IDNet communications wiring. the break-rod is used,it must be replaced.) " This product has been approved by the California State Fire Marshal(CSFM)pursuant to Station testing is performed by physical activation of Section 13144.1 of the California Health and Safety Code.See CSFM Listing the pull lever.Electrical testing can be also performed by 7150-0026:224 for allowable values and/or conditions concerning matedal presented in this document.It Is subject to re-examination,revision,and possible cancellation.Accepted for unlocking the station housing to activate the alarm switch. use—City of New York Department of Buildings—MEA35.93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and '•MAPNET II and IDNet addressable designs are approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products e communications esi 9 protected b y U.S. Westminster. Patent No.4,796,025. S4099-0001-6 10/2003 IFT.N.R. . . Addressable Manual Stations Model Description 4099-9001 Single action 4099-9002 Double action, Breakglass operation Addressable manual station,red housing with white letters and white pull lever 4099-9003 Double action, Push operation Accessories Model Description Reference ?975-9178 Surface mount steel box, red Refer to gage 3 for dimensions 2975-9022 -bast-altarr�inum-sarfaee-maun�box,�Ed-------- - — - - 2099-9813 Semi-flush trim plate for double gang switch box, red 2099-9814 Surface trim plate for Wiremold box V5744-2, red Typically for retrofit,refer to page 4 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 Power and Communications MAPNET II or IDNet, 1 address per station,up to 2500 ft(762 m)from fire alarm control panel,up to 10,000 ft(3048 m)total wiring distance(including T-Taps) Address Means Dipswitch,8 posltlon Wire Connections Screw terminal for in/out wiring,for 18 to 14 AWG wire UL Listed Temperature Range 32°to 120"F(0°to 49"C)intended for indoor operation Humidity Range Up to 93%RH at 100"F(38"F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5"H x 3-3/4"W x 1"D(127 mm x 95 mm x 25 mm) Single Gang Box Mount 4"Square Box Mount Single gang box,2-1/2"deep 4"(102 mm)square box,2-1/8"(54 mm)minimum (64 mm),RACO#500 or equal depth,RACO#231 or equal(supplied by others) (supplied by others) rL L� L� 1 _ � o Mount flush or with 1/16"(2 mm) maximum extension 0 4"Square box o r DO NOT RECESS V J jith cover plate � 1 o , Station FIRE ® ALARM side view Single gang cover plate,3/4" (19 mm)extension,RACO#773 PULL DOWN or equal(supplied by others) 1 Single gang box outline wall surface Semi-Flush Mount Side View fiSNnplex 2 S4099-0001-6 10/2003 2975-9178 Box 2975-9022 Cast Box Preferred Mounting.For 5-3/16"H x 4"W x 2-3/16"D 5"H x 3-7/8"W x 2-3/16"D surface mounting of these (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) addressable manual stations,the (ordered separately) (ordered separately) preferred electrical boxes are shown in the illustration to the right. 0 0 0 0 Additional Mounting Knockouts located Reference. Refer to page 4 for top and bottom_ Wiremold box mounting compatibility. FIRE ® ALARM 0 0 PULL DOWN Access for 3/4"threaded 5.. conduit located top and bottom (127 mm) ss Slmplen � 1"(25.4 mm) �----3-3/4"(95 mm)-►I 4099 Series Addressable Manual Station • - 7 - M. W • Refer to NFPA 72,the National Fire Alarm Code,and all applicable local codes for complete requirements for (32 mm) Simplex 2975-9178 box manual stations.The following (shown for reference)� summarizes the basic requirements. t�' 1. Stations shall be located in the normal path of exit and distributed - in the protected area such that they Address setting under are unobstructed and readily resealable label(accessible accessible. with cover open) P-5/8" 2. Mounting shall be with the (67 mm) operable part not less than 3-1/2 ft (1.1 m)and not more than 4-1/2 ft Station cover (1.37 m)above floor level. installation access hinges open for 3. At least one station shall be provided on each floor.Additional Switch wiring stations shall be provided to obtain (prewired) a travel distance not more than 200 ft(61 m)to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-6 10/2003 i • . For retrofit and new installations,additional O O compatible mounting boxes Wiremold and the required adapter plates 2099-9814 Surface trim O Os r recepttaclact e box model V5744-2 are shown in the illustration to for Wiremold box (supplied by 5-1/8"H x 5"W others) the right. (130 mm x 127 mm) O CD Two gang switch box,each 3"H x 2"W x 2-3/4"D FIRE O (76 mm x 51 mm x 70 mm) (supplied by others) 4099-90011DNet PULL DOWN ° addressable station ! ®�__ O® i z U U 2099-9813 Semi-flush trim for 2 gang O/ p o switch box,6"H x 4-1/2"W (152 mm x 114 mm) Flush mount adapter kit 2099-9819,Black 2099-9820,Beige Box must be recessed into wall 1"to 1-1/8"(25.4 mm to 29 mm) • E ALARM 6 U (203 nun) 0 Hole cutout must be a PULL ��W� minimum of 6"H by 5"W(152 U 6„ (152 mm by 127 mm) mm) 0 U z 4-11/16"(119 mm) square box,2-1/8" (54 mm)minimum Wall depth(by others) 4-3/4"(121 mm) - I surface-�� Front View Side View Tyco,Simplex,the Simplex logo,AYAPNET II,and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S.and/or other countries.NFPA 72 and National Fire Alarm Code are registered trademarks ofthe National Fire Protection Association(NFPA).Lexan is a trademark of the General Electric Co.Wiremold is a trademark of the Wiremold Company. f3 Simplex Tyco Safety Products Westminster•Westminster,MA•01441-0001•USA S4099-0001-6 10/2003 www.tycosafetyproducts-usa-wm.com m 2003 Tyco Safety Products Westminster.All rights reserved.Alf specfications and other information shown were current as of document revision date and are subject to change without notice. U®Simplex TrueA/arm Analog Sensing UL, ULC Listed, FM, CSFM, TrueAlarm Analog Sensors— Photoelectric, and NYC, MEA Approved* Ionization, and Heat; Compatible Bases and Accessories TrueAlarm®analog sensing provides digital Q transmission of analog sensor values via MAPNET II®or IDNetTM,two-wire communications** Fire-alarm control panel-provides: • Individual sensitivity selection for each sensor • Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements • Peak value logging allowing accurate analysis for 4098-9714 TrueAlarm Photoelectric sensitivity selection Sensor Mounted in Base • Automatic,once per minute individual sensor . calibration check that verifies sensor integrity • Automatic environmental compensation Digital Communication of Analog Sensing. • Display of sensitivity directly in percent per foot TrueAlarm analog sensors provide an analog measurement that is digitally communicated to the host • Multi-stage alarm operation control panel using Simplex addressable communications. • Ability to display and print detailed sensor At the control panel,the data is analyzed and an average information in plain English language value is determined and stored.An alarm or other abnormal condition is determined by comparing the Photoelectric smoke sensors: sensor's present value against its average value and time. • Seven levels of sensitivity from 0.2%to 3.7% Intelligent Data Evaluation.Monitoring each sensor's Heat sensors: average value provides a continuously shifting reference • Fixed temperature sensing point.This software filtering process compensates for • Rate-of-rise temperature sensing environmental factors(dust,dirt,etc.)and component aging,providing an accurate reference for evaluating new • Utility temperature sensing activity.With this filtering,there is a significant reduction Ionization smoke sensors*: in the probability of false or nuisance alarms caused by • Three levels of sensitivity;0.5%,0.9%and 1.3% shifts in sensitivity,either up or down. For use with Simplex®: Control Panel Selection.Peak activity per sensor is stored to assist in evaluating specific locations.The alarm • 4010,4020,4100,and 4120 Series control panels set point for each TrueAlarm sensor is determined at the • Universal Transponders and 2120 TrueAlarm CDTs host control panel,selectable as more or less sensitive as equipped for MAPNET II operation the individual application requires. Magnetic test feature Timed/Multi-Stage Selection.Sensor alarm set points Functional and architecturally styled chamber can be programmed for timed automatic sensitivity enclosure: selection(such as more sensitive at night,less sensitive during day).Control panel programming can also provide • Louvered design enhances smoke capture by directing multi-stage operation per sensor.For example,a 0.2% flow to chamber level may cause a warning to prompt investigation while a • Entrance areas are minimally visible when ceiling 2.5%level may initiate an alarm. mounted Sensor Alarm and Trouble LED Indication.Each Optional accessories include remote LED alarm sensor base's LED pulses to indicate communications indicator and output relays with the panel.If the control panel determines that a sensor is in alarm,or that it is dirty or has some other type UL listed to Standard 268 of trouble,the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. These products have been approved by the California State Fire Marshal(CSFM) During a system alarm,the control panel will control the pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM LEDs such that an LED indicating a trouble will return to Listings 7272-0026:218,7271-0026:231,7270-0026:216,and 7300-0026:217 for pulsing het ldenti the alarmed sensors. allowable values and/or conditions concerning material presented in this document.It is P g to P fy % subject to re-examination,revision,and possible cancellation.Accepted for use—City of True New York Department of Buildings—MEA35-93E.Refer to page 4 for ULC listing status. Narrn analog sensors and MAPNET II and IDNet communications are protected by one or Additional listings may be applicable,contact your local Simplex product supplier for the more of the fallowing U.S.Patents:5,155,468;5,173,683;5,543,777;5,400.014;5,552,765; latest status. 5,552,763;4,796,025;DES.377,460. S4098-0019-8 12/01 TrueAlarm Sensor Bases and Accessories I in - . EM TrueAlarm sensor bases contain integral addressable Base mounted address selection: electronics that constantly monitor the status of the detachable photoelectric,ionization,or heat sensors.Each • Address remains with its programmed location sensor's output is digitized and transmitted to the system • Accessible from front(dipswitch under sensor) fire alarm control panel every four seconds. Automatic identification provides default sensitivity Since TrueAlarm sensors use the same base,different when substituting sensor types sensor types can be easily interchanged to meet specific Integral red LED for power-on(pulsing),or alarm or location requirements.This feature also allows intentional trouble(steady on) sensor substitution during building construction.When Locking an design conditions are temiorarily dusty,instead of covering the Magnetically operated functional test smoke sensors(causing them to be disabled),heat sensors Mounts on standard outlet box may be installed without reprogramming the control PTV M- FT"M panel.Although the control panel will indicate an incorrect sensor type,the heat sensor will operate at a 4090-9792,Standard sensor base default sensitivity providing heat detection for building 4098-9789,Sensor base with wired connections for: protection at that location. • 2098-9808 Remote LED alarm indicator or iMounting Reference 4098-9822 relay(unsupervised) 4098-9791,Sensor base with supervised relay driver output(not compatible with 2120 CDT): Electrical Box Requirements:(boxes are by others) • Relay operation is programmable and can be manually Without relay:4"octagonal or 4"square,1-1/2"deep; operated from control panel single gang,2"deep With relay:4"octagonal or 4"square,1-1/2"deep, • Use with remote mount 20984/37 relay with 1-1/2"extension ring • Also includes wired connections for remote LED 4"(102 mm)square Box 4"(102 mm)Octagonal Box alarm indicator or 4098-9822 relay surface mount reference • . Us M1 2098-9737,Remote or local mount supervised relay: C C C C • DPDT contacts for resistive/suppressed loads,power limited rating of 3 A @ 28 VDC;non-power limited 1-1/2"(38 mm) rating of 3 A @ 120 VAC(requires external 24 VDC minimum box depth coil power) Flush mount reference,mount even with final surface,or with up to 1/4"(6.4 mm)maximum recess 4098-9822,LED Annunciation Relay: ,----------------------------------------------- • Activates when base LED is on steady,indicating 2098-9737 Relay(mounts in 4098.9822 Relay(mounts local alarm or trouble base electrical box or remotely) in base electrical box) , • DPDT contacts for resistive/suppressed loads,power ) limited rating of 2 A @ 28 VDC;non-power limited rating of 1/2 A @ 120 VAC,(requires external 24 VDC coil power) 4098-9832,Adapter plate: • Required for surface or semi-flush mounting to ; Relay Size: 2-1/2"x 1-1/2"x 1"(3.75 cubic inches) 4"square electrical box and for surface mounting to (64 mm X 38 mm X 25.4 mm) 4"octagonal box NOTE:Review total wire count,wire size,and accessories • Can be used for cosmetic retrofitting to existing 6-3/8" being wired to determine required box volume. diameter base product '-----------------------------•-------------------- Indica or: Remote red LED Alarm r• 6-3/8"(162 mm) -� Indicator: �— • Mounts on single an box 4098-9832 Adapter Plate, uire for g gang 1/a„ALARM mounting to surface mounted boxes (shown in illustration to right) © (6.4 mm) w g_square jUh hpj 4-7/8"(124 mm) per. 15/16" (24 rr 0 B TrueAlarm Bases 4098-9789,-9791,&-9792 2 S4098-0019-8 12/01 7 TrueAlarm Sensors • ; 1:11M. m, RMUMM-TIT Me TrueAlarm photoelectric sensors use a stable,pulsed Sealed against rear air flow entry infrared LED light source and a silicon photodiode Interchangeable mounting receiver to provide consistent and accurate low power smoke sensing.Seven levels of sensitivity are available EMI/RFI shielded electronics for each individual sensor,ranging from 0.2%to 3.7%per Heat sensors: foot of smoke obscuration. Sensitivity is selected and • Selectable rate compensated,fixed temperature monitored at the fire alarm control panel. sensing with or without rate-of-rise operation The sensor head design provides 360'smoke entry for • Listed to UL Standard 521 for 60 ft(18.3 m)spacing optimum response to smoke from any direction.A built-in for 135'F(57.2°C)alarm,and 40 ft(12.2 m)spacing screen keeps insects from entering the smoke chamber. r 1550 F(680 C)alarm IDuedo-its photoelectric-operation;air velocity is not — - — Smoke Sensors: normally a factor,except for impact on area smoke flow. • Photoelectric or ionization technology sensing r• 4-718"(124 mm)— • • 360°smoke entry for optimum response T LED status Indicator UIRMUCIC2 MF VfMlTem2-1/8" TrueAlarm heat sensors are self-restoring and provide rate (54 mm) compensated,fixed temperature sensing,selectable with or without rate-of-rise temperature sensing.Due to its small thermal mass,the sensor accurately and quickly measures the local temperature for analysis at the fire 4098-9714 Photoelectric Sensor with Base alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15"F(8.3°C)or 20°F(11.1°C) TrueAlarm Ionization sensors use a single radioactive per minute.Fixed temperature sensing is independent of source with an outer sampling ionization chamber and an rate-of-rise sensing and programmable to operate at inner reference ionization chamber to provide stable 135°F(57.20 C)or 155'F(68'C).In a slow developing operation under fluctuations in environmental conditions fire,the temperature may not increase rapidly enough to such as temperature and humidity.Smoke and invisible operate the rate-of-rise feature.However,an alarm will be combustion gases can freely penetrate the outer chamber. initiated when the temperature reaches its rated fixed With both chambers ionized by a small radioactive source temperature setting. [Am 241 (Americium)],a very small current flows in the TrueAlarm heat sensors can be programmed as a utility circuit.The presence of particles of combustion will cause device to monitor for temperature extremes in the range a change in the voltage ratio between chambers.This from 32'F to 155'F(0'C to 68'Q.This feature can difference is measured by the electronics in the sensor provide freeze warnings or alert to HVAC system base and digitally transmitted back to the control panel for problems.(Refer to specific panels for availability.) processing. Three levels of sensitivity are available for each ionization sensor:0.5,0.9,and 1.3%per foot of smoke r 4-718"(124 mm) obscuration. I i= 4-71W(124 mm)�—� ��-•Lc0 status indicator T (60 mm) "--LED status indicator 2-1/8" (54 mm) 4098-9733 Heat Sensor with Base 4098-9717 Ionization Sensor with Base ' • • FM 3�M WARNING: In most fires, hazardous levels of smoke Sensor locations should be determined only after careful and toxic gas can build up before a heat detection consideration of the physical layout and contents of the device would initiate an alarm. In cases where Life area to be protected.Refer to NFPA 72,the National Fire Safety is a factor,the use of smoke detection is highly recommended. Alarm Code. On smooth ceilings,smoke sensor spacing of 30 ft(9.1 m)may be used as a guide.For detailed application information,refer to 4098 Detectors, Sensors, and Bases Application Manual(574-709). 3 S4098-0019-8 12/01 . . M TrueAlarm Sensor Bases Model Description Compatibility Mounting Requirements 4098-9792(C) Standard Sensor Base,no options Sensors 4098-9714,-9733,&-9717 4"octagonal or 4"square box, 1-1/2"min. depth;or single gang box,2"min.depth Sensor Base with connections for Sensors 4098-9714,-9733,&-9717 4098-9789(C) Remote LED Alarm Indicator or 2098-9808 remote LED alarm 4"octagonal or 4"square box Unsupervised Relay indicator or 4098-9822 relay g q Sensor Base with connections for Sensors 4098-9714,-9733,&-9717 Note:Box depth requirements depend Supervised Remote Relay and 2098-9737 remote relay(supervised) on total wire count and wire size,refer to 4098-9791 (C) connections for Remote Alarm 1098-9808 remote alarm indicator or accessories list below for reference. Indicator or llnsupprvisPri Relay 2 4098-9822 relay(unsupervised) TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714(C) Photoelectric Smoke Sensor 4098-9717(C) Ionization Smoke Sensor Bases 4098-9792,4098-9789, Refer to base requirements 4098-0733(C) Heat Sensor and 4098-9791 TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Riggiriments Remote Mounting requires 4"octagonal or 2098-9737 Supervised Relay,mounts remote For use with 4098-9791 base 4"square box, 1-1/2"minimum depth or in base electrical box Base Mounting requires 4"octagonal box, 2-1/8"deep with 1-1/2"extension ring 2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1/2"minimum depth on single gang stainless steel plate Relay,tracks base LED status Bases 4098-9789 and 4098-9791 4098-9822(C) (unsupervised,mounts only in base 4"octagonal box,2-1/8"deep with 1-1/2" electrical box) extension ring Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792,-9789,&-9791 mounted 4"square box and for surface mounted 4"octagonal box Refer to publication 4098 Detectors,Sensors,and Bases Application Manual(574-709)for additional information.ULC listed model numbers are designated by(C)and require a"C"suffix such as 4098-9794C. r • General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC w/data,400 pA typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG Remote LED Alarm Indicator Current 1 mA typical,no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG UL Listed Temperature Range 32"to 100"F(0°to 38"C) Operating with 4098-9717 or 4098-9733 32°to 122"F(0°to 50°C) Temperature Range with 4098-9714 15'to 122°F(-9"to 50"C) Humidity Range 10 to 95%RH Smoke Sensor 4098-9714,Photoelectric Sensor Air velocity is 0-2000 ft/min(0-610 m/min) Ambient Ratings 4098-9717,Ionization Sensor Air velocity is 0-100 ft/min(0-30 m/min):Altitude is up to 8000 ft(2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098.9737(see page 2 for contact ratings) li rt . Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current 270 pA,from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA,from 24 VDC supply 4098-9822 Unsupervised Relay,Requirements for Bases 4098-9789 and 4098-9791(see page 2 for contact ratings) :+. Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply Tyco,Simplex,the Simplex logo,TrueAlarm,MAPNET II,and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S.and/or other countries. NFPA 72 is a registered trademark of the National Fire Protection Association(NFPA). £;Simplex Westminster,Massachusetts 01441-0001 USA www.simplexnet.com S4098-0019-8 12101 ©2001 Simplex Time Recorder Co DBA TEPG-US(a Tyco company),All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice 93®Simplex TrueAlere Multi-Candela Notification Appliances UL, ULC Listed, Visible Notification Appliances with Horn and Synchronized FM Approved* Flash; Non-Addressable, SmartSynCTM Operation Compatible --------------- Audible/visible(AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount _�_Oneratiq_n is compatible with_ADA-requirements(refer to important installation information on page 3) �` I • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens ) - F I R G ., G Operates over a two wire SmartSync circuit to provide: _ • Horns that are controlled separately from strobes on the same two-wire circuit • "On-until-silenced"and"on-until-reset'operation on the same two-wire pair FIR E • Horn control that can be selected to be temporal coded, march time coded,or on continuously • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate • Class B(Style Y)operation requires connection to a compatible SmartSync NAC or to SmartSync Control Wall and Ceiling Mount A/Vs Module(SCM)4905-9938 Class A(Style Z)operation when connected to the • • 4905-9938 SCM or with 4100U series fire alarm control Multi-Candela TrueAlert A/Vs with horn and panel NACs synchronized strobe provide convenient installation Wall mount ANs features: to standard electrical boxes.The enclosure designs are both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output,on-site model inspection,and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Optional adapters and wire guards: Wall mount AN housings are a one-piece assembly • Wall mount AN adapters are available to cover surface (including lens)that mounts to a single or double gang,or mounted electrical boxes and to adapt to Simplex 4"square standard electrical box.The cover can be 2975-9145 boxes quickly removed(a tool is required)and covers are • UL listed red wire guards are available for wall or available separately for color conversion. ceiling mount ANs Ceiling mount ANs install using standard 4"electrical Visible notification appliance(strobe): boxes. Color choice is determined by model number. • 24 VDC xenon strobe;intensity is selectable as 15,30, - • 75,or 110 candela with visible selection jumper secured behind strobe housing During installation,a selection plug at the back of the • UL listed to Standard 1971 housing determines the desired strobe intensity.An • Regulated circuit design ensures consistent flash output attached flag with black letters on a highly visible yellow and provides controlled inrush current background allows the selected intensity to be seen at the side of the strobe lens. Audible notification appliance(horn): This product was not approved by CSFM or MEA(NYC)as of document revision date. • Low current,24 VDC electronic horn with harmonically Refer to page 2 for listing status of wire guards.Additional listings may be applicable; contact your local Simplex product supplier for the latest status.Listings and approvals rich output sound suitable for either coded or steady under Simplex Time Recorder Co,are the property of Tyco Safety Products Westminster. operation " Simplex two-wire strobe synchronization operation is protected by U.S.patent No. • UL listed to Standard 464 5,559,492 and SmartSync hom/strobe operation is protected under U.S.Patent No. 6,281,789. S4906-0002 4/2004 19M. . . Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy,location,local codes,and proper applications provide the ability to activate both the horn and strobe on of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A117.1;the appropriate model building code:BOCA, while the strobe remains flashing.The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-until-reset." • - • • .- 0177,offlWOUTN • Multiple Strobes.When multiple strobes and their • 41000 and 4010 Fire Alarm Control Panels refer to ____---mflections can be seen from one location,synchronized data sheet S4010-0001 for details;refer to data sheet flashes reduce the probability of photo-sensitive reactions S4100-0031 for basic 4100U information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet random flashing.The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation . SmartSync Control Module(SCM)4905-9938(refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela ANs Model Mounting Housing Color "FIRE"Lettering ` Description 4906-9127 Wall Real While 4906-9129 White Red Horn with Multi-Candela Strobe;strobe intensity selectable as: 4906-9128 Red White 15,30,75,or 110 candela;operates with SmartSync two-wire 4906-9130 Ceiling White Red control Wall Mount AN Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 rnm)deep 5-3/8"H x 5-1/4"W x 1-5/8"D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) _ 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output;mounts in 4" 4"x 4-1/8"x 1-1/4"D (102 mm)square box;refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9993 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961" Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"H x 6-1/16"W x 3-1/8"D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927" Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3" (216 mm x 156 mm x 76 mm) 4905-9928" Ceiling Red Adapter Plate,required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension,use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) "UL listed by Space Age Electronics Inc. 2 S4906-0002 4/2004 WITTZEMMM.T. Wall Mount or Ceiling Mount,Common Specifications Rated Range voltage UL Listed Rating Regulated 24 VDC;see Note 1 below e a ULC Listed Rating 20 VDC to 30 VDC per ULC S526-MB78 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 32"to 122"F(0"to 50'C); 10%to 93%,non-condensing at 100"F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 MM2 to 3.31 mm);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Hom-Output Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) Reverberant Chamber, 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA UL 464 Test Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 70 mA 101 mA 184 mA 243 mA at other voltages 24 VDC 60 mA 84 mA 143 mA 185 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC 81 mA 119 mA 216 mA 283 mA at other voltages 24 VDC 70 mA 97 mA 167 mA 217 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired, changes effective May 1,2004.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) 0 0 Mounting is compatible with single gang,double gang,and 1 ° 1 IMPORTANTI WALL MOUNT 4"(102 mm)square boxes, INSTALLATION HEIGHT.REFERENCE 1-1/2"(38 mm)deep,by others o rol " " o " J; Bottom of lens is either even o ) C with,or slightly Electrical o 0 above bottom box outline Wiring access hole 0 of compatible p , boxes Wiring terminals for p 0 1 SmartSync operation i Mounting Holes: NFPA 72 requires 80"(2.03 m) ®avow y 4"square(4) that the entire lens minimum ` Single gang(2) be not less than Double gang(3) 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only from rear of housing: 'g n factory setting is 15 cd Removable]cover Strobe intensity (tool required) viewing slot 3 S4906-0002 4/2004 Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box\ Four mounting clamps included,two each side \1i 0 Ceiling reference, ll_ Oubli muunled hux Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are Optional 4905-9927 located behind the housing Red Wire Guard J �� End View ----------------------------------- J*,, housing; Strobe intensity viewing slot Intensity selection plug, ; \ accessible only from rear of lens i factory setting is 15 cd Mount --------------------------------------- •n Reference; Adapter Plate, Guard, and Adapter Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt o and Optional Wire Guard Surface mount conduit and O box shown for reference 4"(102 mm)square 44 ��+'" O box profile,1-1/2" '-- (38 mm)deep O Optional O — — O 4905-9961 Wire Guard AN H ----- Hill- r� 7 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco,Simplex,the Simplex logo,IDNel,TrueAlerl,and SmarlSync are trademarks of Tyco International AG or its affiliates in the U.S.and/or other countries.NFPA 72 and National Fire Alarm Code are registered trademarks ofthe National Fire Protection Association(NFPA) D Simplex Tyco Safety Products Westminster"Westminster,MA•01441-0001•USA S4906-0002 4/2004 e www.tycosafetyproducts-usa-wm.com 0 2004 Tyco Safety Products Westminster.All rights reserved All specifications and other information shown were current as ofdocument revision date and are suhject to change without notice. 000 COOPER Wheelock Weatherproof Appliances - Series AH Audibles,AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories IRE t.W; Description: Features: The Wheelock Weatherproof Strobe,Audible Strobe,Audible Horn, 0Approvals include: UL Standard 1638 and 464,California Multitone Strobe and speaker strobe appliances have an extended State Fire Marshal(CSFM)and New York City(MEA), temperature range of-31'F to 150T(-35'C to 66°C)for outdoor, Factory Mutual(FM)and Chicago(BFP) wall and ceiling applications. All strobes are Indoor/Outdoor UL 0 Designed to meet or exceed NFPA,/UFC/ANSI 117.1/OSHA Standard 1638 Listed and rated for 180 candela on axis @ 77°F Part 29, 1910.165,and ADA requirements (25°C)and 75 candela at-31°F(35°C)with low current draw. • UL Standard 1638 and UL Standard 464 listed with extended The Wheelock Weatherproof Appliances are designed for maximum temperature range of-31'to 150°F(-35°C to 66°C) performance, reliability, and cost effectiveness while meeting or 0 24 VDC with new UL"Regulated"Voltage Range:of 16-33 exceeding the latest requirements of NFPA72(National Fire Alarm VDC using filtered DC or unfiltered FWR voltage Note: The Code),UL Standard 1638(Standard for Visual Signaling Appliances), UL Standard 464(Standard for Audible Signaling Appliances)and Series MT-12/24 voltage range is 10.5-15.6 VDC(for 12V) UL Standard 1480(Standard for Speaker Appliances). and 20-31 VDC(for 24V) • Sync/Non-Sync in each product. Note: The audible portion Series RSSWP Strobes,Series ASWP Audible Strobes and Series of the Series MTWP and MT 12/24 is non sync only AHWP Audibles may be synchronized when used in conjunction with the Wheelock PS-24-8MC Power Supplies with Patented Sync Synchronize with Series SM, DSM Sync Modules PS-24-8MC Protocol. The Series MTWP is a true 4-wire appliance. The strobe Power Supplies with built-in patented sync protocol portion can be synchronized as stated above. The multitone portion 0 Selectable dBA settings cannot,but it can be connected to a coded fire alarm system. • Selectable alert signals The Wheelock WP-KIT,WFP and WPFAare weatherproof mounting accessories for Cooper Wheelock outdoor products. The WP-KIT 0IN and OUT wiring termination that accepts two#12-18 AWG allows a customer to surface mount a weatherproof backbox(IOB, wires at each terminal WPBB and WPSBB)to a recessed electrical box. The WPA and 0 Inputs are polarized for compatibility with industry standard WFPA kits allow a customer to flush mnount weatherproof products reverse polarity supervision (ASWP, MT, MTWP, ET70WP, RSSWP and AHWP) without an external weatherproof backbox. Gw<ma YL FM M EA APPROVED E5946 151-92-E 7125-0785:131(ASWP) S5391 7125-0785:146(ET70WP) S2652 7125-0785:156(MTWP) 7300-0785:154(RSSWP) U®Simplex TrueAlert° Notification Appliances UL Listed; FM acid SmartSyncTm Adapter Module for Non-Addressable CSFM Approved* Notification Appliance Circuits (NACs) Model 4905-9815 Conventional Converts a SmartSync NAC into separate 24 VDC TrueAlert audible appliance %% audible and visible appliance outputs: non-addressable appliances Power and communications are supplied by the — 1 SmartSync SmartSync operation.NAC _ — _. Adapter • Up to two SmartSync Adapter Modules can be connected to a SmartSync NAC r Operation is compatible with: • Simpler'fire alarm control panels providing LS'"' SmartSync two-wire horn/strobe control • SmartSync Control Module(SCM)model 4905-9938 _ Conventional `. visible appliance.' (refer to data sheet S4905-0003 for additional information) ,1"• NAC with SmartSync 2-wire operation Appliance control output features: • Operation modes are:visible and audible appliances both on; or visible appliance only-with activation determined by the connected control panel �, Fire alarm control panel providing • An on-board DC-DC regulator ensures proper SmartSync operation NACs appliance voltage and provides self-resetting (41000 style shown for reference) overcurrent protection • Audible output rated for up to 50 mA • Visible output rated for up to 250 mA • Wiring to audible and visible appliances is supervised SmartSync Adapter Module, with conventional reverse polarity operation;opens or Typical One-Line Wiring Reference shorts are reported to the control panel Status diagnostics: Special Notification Requirements. Standard • A visible status LED will light if a wiring fault is SmartSync operation notification appliances activate detected by either of the on-board output notification horns and/or strobes in response to commands received appliance supervision circuits from the SmartSync operation control source using a General mechanical features: two-wire connection.For applications where appliances • Mounts in standard 4-11/16"(119 mm)square other than the standard SmartSync appliances are required,the SmartSync Adapter Module provides a electrical box separate audible and visible output controlled by the • Cover plates(required)are available for surface or SmartSync operation control source. flush mount,ordered separately Typical applications are for connection to special • Covers provide status LED viewing weather-proof appliances,appliances with particular • Screw terminals for wiring connections sound output characteristics(special bells or chimes),or UL listed to Standard 864 for connection to appliances that are required to satisfy specific aesthetic requirements. Maintains SmartSync operation System Advantages.With the SmartSync Adapter Module, non-SmartSync appliances can be controlled while still 'This product has been approved by the California State Fire Marshal(CSFM)pursuant to benefiting from the SmartSync operation ability to Section 13144.1 of the California Health and Safety Code.See CSFM Listing provide separate audible and visible control using a 7300-0026:315 for allowable values and/or conditions concerning material presented in two-wire connection(U.S.Patent No.6,281,789). this document.It is subject to re-examination,revision,and possible cancellation.This product was not ULC listed or approved by MEA(NYC)as of document revision dale. Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster S4905-0005-1 6/2003 Compatibility with circuit protectors.When Provisions for shielded wire.For applications where connected to remote appliances(up to 200 ft from the notification appliance wiring may be exposed to electrical adapter)that exit the building and may be exposed to noise,twisted,shielded wiring is recommended.The harsh electrical environments,the notification appliance adapter wiring terminal block has provisions for wiring is compatible with Simplex circuit protectors. connecting the shield(s). Compatible protectors are listed on page 3 and should be connected both where the wiring leaves the building and where it connects to the appliances. Imam- MM Model Description 4905-9815 SmartSync Adapter Module; requires surface or flush mount cover plate 4905-9817 Surface Mount Cover Plate Select one for each 4905-9815; painted beige 4905-9818 Flush Mount Cover Plate • • Cover plate depth: 0.35"(9 mm)for surface mounted box 0.24"(6 mm)for flush mounted box 4-11/16"(119 mm)square box,2"(51 mm) minimum depth;ref.RACO 257[2-1/8" fl (54 mm)deep],or equal(supplied by others) Status indicating LED p SmartSync Adapter Module Assembly i Light pipe for LED viewing SmartSync Adapter Module Detail ,o Q o 5-1/4"(133 mm) square o 0 \ Mounting holes 4- for cover plate(4) (119 mm mm) Depth into box= Terminal block for wiring connections Appliance mode selection switch Holes for connecting to mounting box(4) ° Q oacacrroweR Qo GUM SERv1 W 5"(127 mm) ►I 2 S4905-0005-1 6/2003 Electrical Input Voltage Range 16 to 33 VDC;see notes below Input Current Supervisory 85 pA typical Alarm 12 mA plus audible and visible appliance loads(see NAC loading below) Output Voltage Range 20 to 32 VDC;on-board regulator limits inrush current to appliances at 550 mA Audible Appliance Output Rating 50 mA @ 24 VDC Vi3iblo Appliance Output Rating 260 mA @ 24 VDC On-board regulator is in effect when NAC voltage drops below 20 V;increase appliance current rating by 10%to determine NAC current requirements for worst case line voltage. NAC Loading Impact Example:Assume audible appliance is rated 40 mA;Visible appliance(strobe) is rated 180 mA @ 20 VDC(150 mA @ 24 VDC) Alarm Current=12 mA+(1.1)(180 mA+40 mA)=254 mA Wiring Reference Appliance Distance from SmartSync Adapter 200 ft maximum(61 m) Supervision Resistor 10 kQ,1/2 W;two required,one located at each remote appliance Wiring Connections Screw terminals for 18 to 12 AWG(0.82 mm2 to 3.31 mm2) Compatible Circuit Protection 2081-9044,Overvoltage Protector,200 mA maximum (required when wiring leaves the building for 2081-9028, Isolated Loop Circuit Protector,5 A maximum outdoor appliances,mount one at each end of wiring) 2081-9027, Isolated Loop Circuit Protector,200 mA maximum Mechanical and Environmental Dimensions(adapter mounted in bracket,see 4-11/16"H x 5"W x 1-9/32"D(119 mm x 127 mm x 33 mm) page 2 for reference drawing) Mounting Plate Material Sheet metal,galvanized Temperature Range 32'to 120' F(0°to 49°C)intended for indoor operation Humidity Range 10%to 90%RH non-condensing at 90° F(32'C) NOTES: 1. The SmartSync adapter is required to be connected to a NAC that provides SmartSync two-wire operation. 2. The rated voltage range listed is the absolute operating range.Operation outside of this range may cause permanent damage to the SmartSync adapter. 3 S4905-0005-1 6/2003 Tyco,Simplex,the Simplex logo,and T rueAlert are trademarks of Tyco International Services AG or its afliales in the U.S.and/or other countries. �3 Simplex Tyco Safety Products Westminster•Westminster,MA•01441-0001•USA S4905-0005-1 6/2003 o www.tycosafetyproducts-usa-wm.com 02003 Tyco SafelyProducls Westminster.All rights reserved.Alispecicalions and other information shown were current as ofdocument revision dale and are subject to change without notice. NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120"F(0°C to 49°C)and maximum humidity of 93%(t 2%). • Sorioc NH horno aro lictod undor UL Standard 464 for audiblo cignal appliances(Indoor use only). • "Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the -Aerminology-I'Listed-Voltage-Range". Wall Mount Ceiling Mount Wall or Ceiling Mount I IR RSSWP MTWP RSSWP MTWp MT AH RSSWP ET70WP ASWP ET70WP ET-1010 Strobe Order Code Strobe Order Code Audible Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 AH-24WP-R Red 7416 RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-12WP-R Red 7415 Audible Strobe Audible Strobe Horn ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 MT-12/24-R Red 5023 Multi-tone Strobe ASWP-?475C-FW White 4502 Speaker MTWP-2475W-FR Red 8420 Multi-tone Strobe ET-1010-R Red 3135 MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 ET-1010-W White 3137 Speaker Strobe MTWP-2475C-FW White 4478 ET70WP-2475W-FR Red 9077 Speaker Strobe ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 UL Max.Current AH ET70WP-2475C-FW White 4454 24 VDC 12 VDC High(99)dBA 0.080 0.192 RSSWP,ET70WP and MTWP(strobe only) UL Max.Current ASWP Med(95)dBA 0.043 0.108 UL Max.Current 24 VDC (Audible and Strobe) 24 VDC Low(90)dBA 0.021 0.058 0.138 High(99)dBA 0.168 Med(95)dBA 0.155 UL Max.Cur- MTWP/MT MT Low(90)dBA 0.150 rent(Audible) 24 VDC 12 VDC Model Number Agency Approvals dBA HI STD HI STD UL Reverberant dBA@ 10 Feet Horn 0.108 0.044 0.177 0.034 Watts 1/8 1/4 1/2 1 2 4 8 Strobe UL MEA CSFM FM BFP Bell 0,053 0.024 0.095 0.020 ET-1010 77 80 83 86 87 92 94 RSSWP X X X X March Time 0.104 0.038 0.142 0.034 ET70WP 78 81 84 87 90 93 95 Audible Strobe Code 3 Horn 0.091 0.035 0.142 0.034 ASWP X X X X X Code 3 Tone 0.075 0.035 0.105 0.021 Multitone Strobe Slow Whoop 0.098 0.037 0.142 0.035 MTWP X X X X Siren 0.104 0.036 0.152 0.030 Horns/Audibles Hi/Lo 0.057 0.025 0,114 0.026 AH-24WP X X X X AH-12WP X X X X MT-12/24 X X X X X Speaker Strobe ET70WP X X X Mounting Accessories WFP WFPA IOB WPSBB WPBB WBB Gasket Kit Order Code Mounting Options:WP-KIT 4486 Backboxes,Plates,Gasket Kits Flush Plates Surface Mount Flush WFPA-R Red 4698 Exposed Conduit Concealed Conduit Mount WFPA-W White 4701 RSSWP Strobes WPSBB WPSBB+WP-KIT WFP WFP-R Red 469 WFP-W White 4697 ET70WP Speaker Strobes 106 IOB+WP-KIT WFP Backboxes ASWP Hom Strobes WPBB WPBB+WP-KIT WFPA IOB-R Red 5046 AHWP Horns WBB - WFP IOB-W White 5047 WPSBB-R Red 9751 ET-1010 Speakers WBB - WFP WPSBB-W White 3033 MTWP Multitone Strobes IOB IOB+WP-KIT WFP WPBB-R Red 9014 Multitone IOB IOB+WP-KIT WFP WPBB-W White 4692 WBB-R Red 2959 WBB-W White 2960 SERIES MTWP APPLIANCES SYNCHRONIZED STROBE j Wiring Diagrams OPERATION WITH CODED FACP MTWP m -0 e -o Strobe uit SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE mmlule IN UNISON.RED AND BLACK SHUNT-WIRES ARE SUPPLIED. NAC M1 or PS-12/244 —0 Audible Power Circuit FROM FACP Supply PRECEDING + + TO NEXT kPPLIANCE Ran APPLIANCE NAC Y2 BLACK - OR EOLR �R FACP Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ + - 0 + - DSM MODULE SINGLE CLASS"A"NAC CIRCUIT STROBE AUDIBLE DSM STROBE SERIES RSSWP,ASWP,AHWP,MTWP AND MT-12/24 NAC SYNC+ 0 CIRCUIT 0 APPLIANCES OUT •O -,I 0+IN 1 RSS) FRM TO NEXT 0- PRECEDING + ± APPLIANCE 'MINUS I APPLIANCE OR OR EOLR FACP +AUDIBL FACP � � M]NUS 2 +IN 2 RSS ")N* RSS TROBL + NAC 07 otrr 2 CIRCUIT RETURN Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. ARCHITECTS AND ENGINEERS SPEC'—'CATIONS The Weatherproof Strobe appliances shall L Vheelock Series RSSWP-2475 strobes or appro._J equals for wall and ceiling mount applications. The Series RSSWP shall meet and be listed for UL Standard 1638(Standard for Visual Signaling Appliances)for Indoor/ Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan@ lens. The strobe shall be rated at 75cd and shall operate over an extended temperature range of-31°F to 150°F (-35°C to 66°C). All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by-a Fire Alarm Control Panel.--When synchronization is-required,the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-12/24-8MP Power Supply with built-in,patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The Series RSSWP shall be mounted only to the WPSBB-R Backbox. The Weatherproof Audible Strobe and Audible appliances shall be Wheelock Series ASWP-2475 Audible Strobes for wall and ceiling mount applicaitons and Wheelock Series AHWP Audible Horns for wall mount or approved equals. The Series ASWP and Series AHWP shall meet and be listed for UL Standard 1638(Standard for Visual Signaling Appliances)for Indoor/Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan@ lens. The strobe shall be i aled 180cd c@i 77"F(25"C)and 75cd al-31"F(-35"C)and shall operate over ar-esden a -temperature-range at- to 150*F(-35oC to 66 arid be listed"for maximum humidity at 95%RH-Aliinputs shalt be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP). The Series ASWP shall be mounted only to the WPBB-R Backbox while the Series AHWP shall only be mounted to the WBB-R Backbox. The weatherproof audible strobe appliances shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3)tone when constant voltage from a Notification Appliance Circuit(NAC)of the Fire Alarm Control Panel(FACP)is applied. They shall be designed so that the audible signal may be silenced while maintaining strobe activation. When synchronization is required,the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-12/24-8MP Power Supply with built-in,patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync fails to operate,(i.e.,contacts remain closed),the strobe shall revert to a non-synchronized flash rate. The Weatherproof Multitone Strobe and Multitone Audible appliances shall be a Wheelock Series MTWP and MT-1 2/24 or equivalent. The Series MTWP shall meet and be listed for UL Standard 1638(Standard for Visual Signaling Appliances)for indoor/outdoor use. The strobe portion of the appliance shall produce a flash rate of 30-62 flashes per minute over the listed voltage range of 20-31 VDC and shall incorporate a Xenon flash tube enclosed in a rugged Lexan@ lens. TThe strobe shall be rated 180cd @ 77°F(25°C)and 75cd at-31°F (-35°C)and shall operate over an extended temperature range at-31°F to 150°F(-35"C to 66°C)and be listed for maximum humidity at 95%RH. All inputs shall be polarized for compatibility with industry standard reverse polarity of circuit wiring by a Fire Alarm Control Panel. The audible portion of the Series MTWP as well as the Series MT-1 2/24 shall provide eight field selectable alarm signals. The signals shall consists of: Horn,Bell,March Time,Code 3 Horn,Code 3 Tone,Slow Whoop,Siren and Hi/Lo. Tone selection shall be by a durable dip switch assembly. Clips or Jumpers are not acceptable. The appliance shall provide two output sound levels: Standard and High dBA. The range of dBA shall be 75 to 94 dBA. The Series MTWP shall have an operating voltage of 24 VDC(nominal)while the Series MT-12/24 shall operate at either 12 or 24 VDC(nominal)using filtered power or unfiltered power(full wave rectified). Both models shall have provisions for In/Out field wiring using terminals that accept#12 to#18 AWG wiring. When synchronization is required, the Series MTWP shall be compatible with the Series SM and DSM Sync Modules or with the Series PS-12/24-8MP Power Supply with built-in,patented sync protocol. Note: The Strobe portion of the Series MTWP may be synchronized. The audible portion of the appliance cannot. The audible portion of the appliance can be connected to a coded fire alarm system. The Series MTWP and the Series MT-12/24 shall be mounted only to the IOB-R Backbox. The Weatherproof Low Profile Speaker Strobe shall be Wheelock Series ET70WP for wall and ceiling applications or approved equal. The Series ET70WP shall meet and be listed for UL Standard 1638(Standard for Visual Signaling Appliances)for Indoor/Outdoor use, Fire Protective Service and UL Standard 1480(Standard for SpeakerAppliances.The strobe portion of the ET70WP shall produce a flash rate of 3U-162 flashes per minute over the Regulated Voltage Flange of 1b to 33 VD(;and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens to provide maximum visibility and reliability for effective visible signaling. The strobe shall be rated 180cd @ 77°F(25°C)and 75cd at-31°F(-35°C)and shall operate over an extended temperature range at-31°F to 150°F(-35°C to 66°C)and be listed for maximum humidity at 95% RH. For outdoor applications the ET70WP shall be wall mounted to a weatherproof back box (1013).The speakers shall be designed for multiple power requirements with a high dBA output at each power tap.The low profile model shall offer a choice of field selectable taps,1/8W to 8W for either 25.0 VRMS or 70.0 VRMS audio systems.The low profile design shall incorporate a high efficiency speaker for maximum output at minimum power across a frequency range of 400Hz to 4000Hz and features a sealed back construction for extra protection and improved audibility. Mounting Accessories The weatherproof mounting plate shall be a Wheelock WFP or approved equal for semi-flush mounting of weatherproof models AH-12WP, AH-24WP,MT-1 2/24,MTWP,RSSWP,ET70WP and/or ET-1010 appliances. The WFP shall allow for the weatherproof appliance to be mounted to a recessed 4-inch square back box without the need for a weatherproof surface box. The weatherproof mounting plate shall be a Wheelock WFPA or approved equal for semi-flush mounting of weatherproof model ASWP appliances. The WFPA shall allow for the weatherproof appliance to be mounted to a recessed 2 gang or a recessed 4-inch square back box without the need for a weatherproof surface box. The weatherproof mounting shall include a Wheelock WP-KIT or approved equal for weatherproof back box models 1OB,WPBB and WPSBB. The WP-KIT shall allow the weatherproof back box to be mounted to a single gang or double gang recessed back box. 00 COOPER Wheelock 273 Branchport Avenue L, Long Branch,NJ 07740 Phone: (800)631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732)222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S9004 WP 06/06 tyco Fire& Security SimplexGrinnell HARDWARE WARRANTY 1) SIMPLEXGRINNELL WARRANTY STATEMENT: a) SIMPLEXGRINNELL WARRANTS TO THE PURCHASER OF NEW SIMPLEXGRINNELL PRODUCT(S)THAT THE PRODUCTS SHALL BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL. 2) WARRANTY PERIOD: a) THE WARRANTY PERIOD WILL TERMINATE IMMEDIATELY FOLLOWING THE EARLIEST OCCURRENCE OF EITHER OF THE FOLLOWING: i) 18 MONTHS HAVE ELAPSED FOLLOWING SHIPMENT OF ANY SYSTEM OR SUB- SYSTEM FROM SIMPLEXGRINNELL TO THE CUSTOMER, OR ii) 12 MONTHS HAVE ELAPSED FOLLOWING THE FINAL CONNECTION OPERATION AND BENEFICIAL USE OF ALL OR ANY PART OF THE SYSTEM. iii) AS STATED IN THE SPECIFICATIONS AND/OR CONTRACT DRAWINGS 3) SIMPLEXGRINNELL OBLIGATION UNDER THE TERMS OF THE WARRANTY: a) SIMPLEXGRINNELL'S SOLE RESPONSIBILITY SHALL BE TO REPAIR,ADJUST OR REPLACE, AT ITS OPTION,ANY SIMPLEXGRINNELL PRODUCT WHICH FAILS DURING THIS PERIOD PROVIDING PURCHASER HAS PROMPTLY REPORTED SUCH FAILURE TO SIMPLEXGRINNELL IN WRITING. REPLACEMENT PARTS WILL BE WARRANTED ONLY FOR THE BALANCE OF THE EQUIPMENT WARRANTY. SIMPLEXGRINNELL AGREES TO CONTINUE TO HONOR ALL OF THE UNEXPIRED EXPRESSED WARRANTIES SPECIFIED ABOVE ON DEFECTIVE EQUIPMENT AFTER TRANSFER OF THE EQUIPMENT TO PURCHASER'S CUSTOMER, PROVIDED PURCHASER'S CUSTOMER ASSUMES THE PURCHASER'S OBLIGATIONS SPECIFIED BELOW. b) EXCEPT FOR THE EXPRESSED WARRANTIES STATED HEREIN, SIMPLEXGRINNELL DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING WITHOUT LIMITATION,ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,AND THE STATED WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR LIABILITIES ON THE PART OF THE SIMPLEXGRINNELL ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE PRODUCTS. THE SELLER SHALL NOT BE LIABLE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE TO THE PRUCHASER OR USER OF THIS EQUIPMENT ARISING OUT OF THE FAILURE OF THE EQUIPMENT TO OPERATE IN EXCESS OF THE PURCHASE PRICE OF SAID EQUIPMENT. c) SIMPLEXGRINNELL MAKES NO WARRANTY AND NO WARRANTY SHALL BE DEEMED TO EXIST,THAT PURCHASER HOLDS THE GOODS FREE OF THE CLAIM OF ANY THIRD PERSON BYWAY OF PATENT INFRINGEMENT OR THE LIKE. 4) PURCHASER'S OBLIGATIONS UNDER THE TERMS OF THE WARRANTY. a) THIS WARRANTY IS CONTINGENT UPON THE PROPER INSTALLATION AND USE OF THE PRODUCT(S). SUCH WARRANTY SHALL NOT APPLY IF THE PRODUCT FAILURE IS THE RESULT OF ACCIDENT, UNUSUAL PHYSICAL, ELECTRICAL OR ELECTROMECHANICAL STRESS, NEGLECT, MISUSE, USER PROGRAMMING ERRORS, FAILURE OF ELECTRICAL POWER,AIR CONDITIONING OR HUMIDITY CONTROL, CONSTRUCTION DUST, DAMAGING FOREIGN SUBSTANCES,TRANSPORTATION OR CAUSES OTHER THAN MANUFACTURING DEFECT. PURCHASER AGREES TO PROVIDE FULL AND FREE ACCESS TO AUTHORIZED SIMPLEXGRINNELL EMPLOYEES. Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World tyco Fire& Security Simp/exGrinne// 5) WARRANTY SERVICE HOURS: a) SERVICES PROVIDED UNDER THIS WARRANTY WILL BE PERFORMED DURING THE HOURS OF 8:OOA.M.TO 5:OOP.M., MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEXGRINNELL HOLIDAYS. OFF HOURS RESPONSE IS AVAILABLE AS AN EXTRA COST SERVICE OPTION. 6) WARRANTY EXCLUSIONS: a) LABOR,TRAVEL,AND MILEAGE FOR: i) SERVICE OUTSIDE OF SIMPLEXGRINNELL NORMAL BUSINESS HOURS. ii) PROGRAMMING AND/OR LABEL CHANGES. iii) FAILURE DUE TO EXTERNAL CAUSES(LIGHTNING SURGES, CONSTRUCTION DUST, ETC.) OTHER THAN MANUFACTURING DEFECT. b) ELECTRICAL WORK EXTERNAL TO THE EQUIPMENT SUPPLIED BY SIMPLEXGRINNELL OR MAINTENANCE OF ACCESSORIES,ALTERATIONS,ATTACHMENTS OR OTHER DEVICES NOT FURNISHED BY SIMPLEXGRINNELL. c) BATTERIES d) COVERAGE OF EQUIPMENT CLASSED AS A WATER FLOW MONITORING/CONTROL DEVICES INSTALLED IN OR ON WATER PIPING. Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World tyco Fire& Security Simp/exGrinne// MANUFACTURER'S RECOMMENDATION 1. CONTRACTOR IS EXPECTED TO PULL AND TERMINATE ALL CONDUCTORS AND INSTALL ALL DEVICES FOR A COMPLETE AND OPERATING SYSTEM. 2. WHERE FAN SHUTDOWN, ELEVATOR RECALL OR SPECIAL AUXILIARY FUNCTIONS ARE REQUIRED, CONTRACTOR IS TO VERIFY WIRING REQUIREMENTS WITH THE SIMPLEXGRINNELL FACTORY TECHNICIAN ASSIGNED TO THE PROJECT(IN MANY CASES, SPECIAL WIRING WILL NOT BE SHOWN ON THE DRAWINGS). 3. WHERE POSSIBLE,THE CONTRACTOR IS TO USE COLOR CODE FOR ALL WIRING. 4. SMOKE DETECTORS ARE NOT TO BE MOUNTED WITHIN 3 FEET OF AIR OUTLETS. 5. CONTRACTOR MUST NOT INSTALL SMOKE DETECTOR HEADS IN BASES OR DUCT HOUSING UNTIL FINAL CHECKOUT TIME TO INSURE THAT DIRT OR DUST DOES NOT CONTAMINATE THE UNITS. DIRTY DETECTORS ARE NOT COVERED BY WARRANTY. 6. DO NOT POWER-UP SYSTEM UNTIL SIMPLEXGRINNELL FACTORY TECHNICIAN IS PRESENT. 7. A SEPARATE GROUND(ISOLATION FROM CONDUIT GROUND) MUST BE PULLED TO ALL CABINETS. 8. LOADS GREATER THAN 10 AMPS(FOR AUXILIARY FUNCTIONS)ARE NOT ALLOWED IN THE SAME CONDUIT AS FIRE ALARM. 9. CONTRACTOR IS TO ENSURE THAT ALL WIRING AND SHIELDS ARE FREE OF SHORTS, GROUNDS AND OPENS. 10. UNDERGROUND WIRING MUST MAINTAIN ONE MEGAOHM,20F RESISTANCE TO GROUND. 11. ANY MANUFACTURER'S RECOMMENDATION IN CONFLICT WITH ENGINEERING DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION, CONTRACTOR SHALL ADVISE SIMPLEXGRINNELL OF ANY CHANGES. 12. PROTECTIVE COVERS ON SMOKE DETECTORS ARE NOT TO BE REMOVED UNTIL OWNERS ACCEPTANCE OF THE SYSTEM. (PREVENTS CONTAMINATION OF SMOKE CHAMBER). 13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REQUEST THE STATE OR LOCAL FIRE MARSHAL TO BE ON SITE FOR FINAL ACCEPTANCE AND CHECK OUT IF REQUIRED. 14. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INVENTORY ALL EQUIPMENT RECEIVED FROM SIMPLEXGRINNELL AGAINST THE CONTRACT DOCUMENTS AND REPORT ANY DISCREPANCIES WITHIN THIRTY(30) DAYS OR SIMPLEXGRINNELL WILL ASSUME THE ORDER TO BE ACCURATE AND COMPLETE. a. "NOTE: IN THE EVENT OF DISCREPANCIES IN THE NUMBER OF DEVICES SUPPLIED, THE FOLLOWING SIMPLEXGRINNELL POLICY WILL APPLY: i. TOO FEW DEVICES: IF THE DEVICE IS SHOWN ON THE CONTRACT DOCUMENTS AND HAS NOT BEEN ADDED AS A RESULT OF A POST BID ADDITION OR CHANGE ORDER, SIMPLEXGRINNELL WILL SUPPLY THE DEVICE AT NO CHARGE TO THE CONTRACTOR OR END USER PER SIMPLEXGRINNELL'S CONTRACT OBLIGATIONS. Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World tgco Fire& Security Simp/exGrinne// ii. TOO MANY DEVICES: IF THE DEVICE SHOWN IS EXTRA, DUE TO A POST BID ADDITION OR CHANGE ORDER; IT REMAINS THE PROPERTY OF THE CONTRACTOR OR END USER. IF THE DEVICE IS EXTRA DUE TO AN ERROR IN QUANTITIES SUPPLIED,THE DEVICE MUST BE RETURNED TO SIMPLEXGRINNELL. NO CREDIT WILL BE ISSUED FOR THE RETURN OF _ EXTRA EQUIPMENT ABOVE THE QUANTITIES GIVEN IN THE CONTRACT DOCUMENTS. 15. OWNERS PRESENCE FOR FINAL DEMONSTRATION AND ACCEPTANCE. SPECIAL INSTRUCTIONS-SIMPLEXGRINNELL 1. SIMPLEXGRINNELL WILL PROVIDE WIRING INSTRUCTIONS FOR INSTALLATION OF SIMPLEXGRINNELL EQUIPMENT. 2. SIMPLEXGRINNELL WILL PROVIDE A FACTORY TRAINED TECHNICIAN TO ASSIST IN TRAINING: a. OPERATION OF THE CONTROL PANEL AND FUNCTIONS b. ALARM TEST OF ALL SIMPLEXGRINNELL PERIPHERAL DEVICES (SMOKE DETECTOR, MANUAL PULL STATION, ETC.) c. SUPERVISE TEST OF ALL INITIATING, SIGNALING, AND CONTROL CIRCUITS. 3. SIMPLEXGRINNELL WILL PROVIDE(1) INSTRUCTION AT FINAL TEST OF THE SYSTEM TO: a. OWNER REPRESENTATIVE b. FIRE INSPECTOR AND ELECTRICAL INSPECTOR c. ARCHITECT AND ENGINEER 4. UPON COMPLETION OF FINAL TEST, SIMPLEXGRINNELL WILL PROVIDE: a. TEST REPORT b. CERTIFICATION-(IF REQUIRED) C. ONE YEAR WARRANTY Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World f-yco Fire& Security Simp/exGrinne// TESTING PROCEDURE FOR DEVICES GENERAL: FOR ALL DEVICES (SUPPLIED BY SIMPLEXGRINNELL)VISUALLY VERIFY PROPER LOCATION AND INSTALLATION. SMOKE DETECTOR: ACTIVATE THE DEVICE USING A SMOKE GENERATOR AND VERIFY ALARM CONDITION ON PANEL. RESET PANEL AND VERIFY RESET OF SMOKE DETECTOR AND PANEL. TEST FOR ALATW VERIFICATION IF APPROPRIATE. HEAT DETECTOR: FIXED TEMPERATURE REPLACEMENT ELEMENT- REMOVE ELEMENT ON HEAT DETECTOR TO INITIATE ALARM AND VERIFY ALARM CONDITION AT PANEL. REINSTALL ELEMENT, RESET SYSTEM,AND VERIFY. NON-REPLACEABLE ELEMENT-NON-REPLACEABLE ELEMENT HEAT DETECTORS CAN ONLY BE TESTED FOR CONTINUITY. RATE-OF-RISE DETECTORS- RATE OF RISE DETECTORS ARE TESTED WITH A HEATER OR BLOW DRYER UNTIL THEY INITIATE ALARM,THEN ALLOWED TO COOL. RESET PANEL AND VERIFY. PULL STATIONS: ACTIVATE STATION WITH THE T-HANDLE,VERIFY ALARM AND LABEL FOR LOCATION, RESET STATION, RESET PANEL. DUCT DETECTOR: (PROVIDED BY SIMPLEXGRINNELL) REMOVE DUCT DETECTOR HOUSING COVER AND ACTIVATE DEVICE WITH SMOKE,VERIFY ALARM,TEST ALL INDICATORS OR MANUAL TEST SWITCHES, RESET DETECTOR, RESET PANEL,TEST SAMPLE AND REFERENCE TUBE FOR POSITIVE AIR FLOW. (IF NOT PROVIDED BY SIMPLEXGRINNELL)VERIFY THAT ZONE CIRCUIT IS PRESENT AT THE DEVICE. AUDIBLES AND VISIBLES: ACTIVATE ALARM AND CONFIRM THAT ALL INDICATING APPLIANCES,AUDIBLES AND VISIBLES, ARE OPERATING. DOOR HOLDERS: VERIFY THAT DOORS CLOSE ON ALARM. VALVE SUPERVISORY SWITCHES (TAMPER): (IF PROVIDED BY SIMPLEXGRINNELL)ACTIVATE SWITCH BY MOVING VALVE OFF NORMAL, VERIFY STATUS CHANGE, RESET SWITCH, RESET PANEL. (IF NOT PROVIDED BY SIMPLEXGRINNELL)VERIFY THAT ZONE CIRCUIT IS PRESENT AT THE SWITCH. FLOW SWITCHES AND PRESSURE SWITCHES: (IF PROVIDED BY SIMPLEXGRINNELL)ACTIVATE SWITCH(WITH SPRINKLER CONTRACTOR PRESENT) BY A FLOW OF WATER,VERIFY STATUS CHANGE, RESET SWITCHES, RESET PANEL. (IF NOT PROVIDED BY SIMPLEXGRINNELL)VERIFY THAT ZONE CIRCUIT IS PRESENT AND SUPERVISED AT THE SWITCH. FAN/DAMPER CONTROL CIRCUITS: VERIFY(WITH HVAC CONTRACTOR PRESENT)THAT THE CONTROL CIRCUIT IS OPERATING AND THE DEVICES IS BEING CONTROLLED IN ACCORDANCE WITH THE SPECIFIED SEQUENCE OF OPERATION. ELEVATOR CONTROL CIRCUITS: VERIFY(WITH ELEVATOR CONTRACTOR PRESENT)THAT THE ELEVATOR IS BEING CONTROLLED IN ACCORDANCE WITH THE SPECIFIED SEQUENCE OF OPERATION. TRAINING: SIMPLEXGRINNELL SHALL PROVIDE A ONE TRAINING SESSION TO THE CUSTOMER. WARRANTY: THE SYSTEM SHALL BE PROVIDED WITH A ONE YEAR HARDWARE WARRANTY. Fire,Security,Communications,Workforce Solutions,Sales&Service Offices&Representatives in Principle Cities throughout the World • � . w :! �.