HomeMy WebLinkAbout18914 59TH DR NE UNIT B_066923_2026 INSPECTION REPORT
/,l
1;4
T Permit No.: e4-C72�3 Lot #:
Address: 109/41Contractor: fi �� coy& AlLJOwner:�1 �!/.fLSo y 4 vcar� Date:
--
❑ APPROVAL ❑ PARTIAL APPROVAL
❑ VIOLATION ❑ CORRECTION REQUESTED
❑ Corrections listed below MUST BE MADE before work can be approved.
❑ Please contact inspector.
❑ Was not able to perform inspection.
❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required.
2 W�it/6 ss�� TEST �f ��.t�Ti«L S Tylt Tla.fJ
mar a TGlf�S:
L
GS �
Inspector: Date: S '-8
or
TYPE OF INSPECTION REQUESTED
❑ Under-floor ❑ Framing ❑ Gas Piping
❑ Footing ❑ Drywall, Nailing ❑ Consultation
❑ Foundation ❑ Shear Nailing ❑ Groundwork
❑ Mechanical ❑ Grid ❑ Struct. Slab
❑ Wood Stove ❑ Rough-in ❑ Final
❑ Masonry ❑ Drainage ❑ Insulation
❑ Other:
C I TY OE ARL- I IV(3-1__C3"
C O N S T R U C T I C3M P E R M I -T-
M I 'T P4C:) - SEA -.-6C323
Owner: JOHNSON HANGARS
Value of Work: $14, 022. 00 Tam, ID : Phone:
Describe Work: FIRE ALARM
Proposed Use: AIRCRAFT HANGAR
Legal Description:
Job Address: 18914 59TH DRIVE NE
Contractor's Name Type Address License*
FIRE COMMERCIAL NORTHWEST CPR PO BOX 3932 FIRECNL986NR
- - P E R M I T F E E S
Equipment and Fixtures Number Fee Total Charge
- - - -------- --- ------ - - - ------ - - --- - ---- -----------
FIRE ALARM INSPECTION 1 $338. 00 $338, 00
S U H T O T A L. . . . . . $338. 00
i
TOTALS Fee
Consultant Fee $338. 00 '
Permit Fee $179. 50
SIGNATURE: '
TOTAL FEE. . . . . . . . . . . . . . . . . $517. 50 I HEREBY CE FY THAT _ I V 'EAD
A EXAMINED HIS APPLICA ION AND
PAYMENTS. . . . . . . . . . . . . . . . . . $0. 00 K W THE SAME TO BE TRUE AND COR-
R C ' ALL OVIS 3NS F LAWS AND
TOTAL DUE. . . . . . . . . . . . . . . . . $517. 50 D NANC INCTHIS TYPE OF
R WILL F IE WITH WHETHER
I • IED ' 3 N T.
DATE RECEIPT #
( DING OFFICIAL
V
Y �^ FIRE ALARN►
o PERMIT APPLICATION
N G� Department of Community Development
City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3431 • FAX(360)403 3447
THIS APPLACATION MUST BE ACCOMPANIED BY FOUR(4)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE
ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION
SHEETS, WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO
BE INSTALLED PRIOR TO INSTALLATION.
Type of permit: (check one) ) New Fire Alarm ( ) Fire Alarm Alteration/Addition
Project Address: �6a`A- Parcel ID#:
Number of Zones/Panels: —Building Area(Sq Ft):
Owner: Phone Number:
Address: City: State: Zip Code:
Contact Person: u [A Phone Number: `,
Cell Phone: Fax: -?_-t`.)(> •ZJLV-k E-mail: `� ��\u �.\c,1���E ['ll'�•tf�l��
Address: VIC «�'x ��t ? - City: State: LL) �SN Zip Code: (� ,— . L?
Contractor: l J P �'yw� �11� Phone Number: ZCAc, zy 1C�0
tox Sri. \ L=-� 1'f,q'l2-`-1
Address: City: -State: Zip Code:
Contractor's License Number: =\ZL Lf\L`16E>b\�� Expiration: C-,
Electrical Contractor. hLj Phone Number:
Address City State Zip Code:
Contractor's License Number: Expiration
I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described
property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for
providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is
complete.
\J — Appl-ic ants Signature Date
Print Applicants Na a PPCEI {ED
C T:;;;0
N V
FOR STAFF USE ONLY
> a ) .
Permit'1 Accepts By Amoun ed R e t# Date Received
WEB Form—22 Page 1 of 1 5/05 dwa
March 20, 2006
TO: Dave Anderson
Building Official
City of Arlington
Arlington, WA
FR: Jim Tracy
Code Consultant
Tracy III Enterprizes
Woodinville, WA
RE: Johnson Hanger
18914 59th Drive NE.
Arlington, WA
Job No. 06-6923
PLAN REVIEW
FIRE ALARM SYSTEM
We have reviewed the fire alarm system plan and specifications submitted by Fire Com
NW, of Seattle, WA.
The plan is approved subject to field inspection and acceptance test.
For inspection call Jim Tracy at 206-940-9622.
PO Box 3932
Seattle WA 981243932
206-234-6700
Firs Com &W, LLC
Battery Calculation Work Sheet
Project- Johnson Hangar Project
18914 — 59th Drive NE
Arlington WA 98223
This project consists of a new fire alarm system for a new aircraft hangar building. The building is
fully sprinklered. This scope of work will include installing a new fire alarm control panel and
initiating devices and signal device.
Qty Part# and description Supervised Current mA Alarm Current mA
1 D7024 Radionics FACP 269 380
1 2WB Smoke detector .0045 .0045
1 ASWP Weatherproof horn strobe 0 128
Subtotal 269 508
Total battery power hours x24 x.083
Subtotal 6456 42
Safety factor - 10% +646 +4
Total 7102 ma 46 ma
Total Current Required 7148 ma or 7.2 amps
Battery size used: 2ea - 12volt, 12amp
RECEIVED
1 WE -3 Z, By
a By W�' $ MAR ► 0116
rife Aiarm Dysiems I u/DY,"�fessaDle nre marm L ofnrol r'anels
D7024 Addressable Fire Alarm
Control Panels
t�lFire Systems
.. Four detector zones(expandable
` to eight);up to 20 two-wire smoke
`., •_ ;'` detectors per zone
• 1 _-� Built-in DACT
Up to 58 programmable relay
•' _ outputs and 255 addressable
•'�: L=- - points
`• _ ;: �� _ Two NACs on board with internal
24 VDC,4 A NAC power supply
ti .� -r�� Programmable through front
•', panel interface,remote D7033 Fire
System Keypad,or remote
programming software(RPS or
RPS-LITE)
The D7024 Addressable FACPs can be used in commercial and Functions
public building applications such as schools,universities, Notification Appliance Circuits(NACs)
manufacturing plants,and health care facilities.They are listed Two notification appliance circuits(NAC)provide up to 4 A of
by UL for central station,local,auxiliary,and remote station 24 VDC power to operate horns,strobes,bells,and other
systems. notification appliances.Each NAC can be programmed to
Adding the D7039 Multiplex Expansion Modules to the provide Temporal Code 3,steady,pulsed,and synchronized
D7024 Conventional Fire Alarm Control Panels(FACPs)with output for Wheelock'and GentexTM notification appliances.
version 2.02 or higher firmware makes the FACPs addressable User Interface
with up to 255 addressable points.The FACPs support both A viewing port in the keyed panel enclosure door leaves the
two-wire and four-wire detectors.Each FACP has a built-in system status LEDs and LCD display visible while maintaining
digital fire alarm communicator transmitter(DACT)and four system keypad security.Unlocking the enclosure door
on-board detection zones that can be expanded to eight zones. Provides access to the system keys for silencing alarm and
Each zone can support up to 20 two-wire detectors,or any trouble conditions,zone bypassing,detector resetting,testing,
number of four-wire detectors(depending on available other fire functions,and programming.These functions are
also available on all D7033 Liquid-crystal Display(LCD)
power). Keypads connected to the system.All D7036 Liquid-crystal
Display(LCD)Annunciators provide custom text
annunciation on a 32-character,backlit,two-line LCD display.
All system keypads and annunciators have built-in sounders.
Back-light intensity and sounder volume are programmable.
Personal Identification Numbers(PINs)
There are 100 PINs available for accessing system control.
Assign each number an authority level to limit the system
control functions that can be accessed.
BOSCH
✓1U49 ICJJdU1U rI1C MAIM VUIILIVI r-wit IJ I J
D7024 Four-zone FACP with Technical Specifications
D7039 Multiplex Expansion D7024 Addressable Fire Alarm Control Panels
Module Enclosure Design
Order Number D7024 and D7039 Color: Red
Dimensions(HxWxD): 20.8 in.x 15 in.x 4.3 in.
Parts included (52.8 cm x 38.1 cm x 10.9 cm)
Material: Cold-rolled steel
In the shipping box are: Base:18 gauge(1.2 mm)
Quant. Component Cover:19 gauge(1.1 mm)
1 D7024 Control Panel Environmental Considerations
1 Enclosure with transformer
Temperature(operating): +32°F to+120°F(0°C to+49°C)
Outputs
1 Enclosure lock,washer,and two keys NAC: 24 VDC nominal,4 A maximum
1 Hardware pack On-board Relays: Two Form C contacts rated at 5 A,
6 EOL resistors(2.21 k"P/N:25899) 28 VDC
Off-board Relays: Up to two D7035 Octal Relay Modules
Note: The D7039 Multiplex Expansion Module must be
each providing eight Form C relay
ordered separately and is delivered in its own outputs;contacts rated at 5 A,
shipping box. 28 VDC;up to 20 D7053 Multiplex
Input-Output Modules per bus for a
D7024LC Four-zone FACP with total of 40
D7039 Multiplex Expansion Polder Requirements
Power(primary) 120 VAC,1.5 A maximum,60 Hz
Module without Enclosure Sensor Circuits
Order Number D7024LC and D7039 Current: 44 mA maximum per loop
Line resistance: 150 S2
Parts included Voltage: 24 VDC nominal
In the shipping box are: Trademarks
Quant. Component
CleanMe®is a trademark of GE Interlogix.
Hardware
Wheelock'is a trademark of Wheelock,Inc.
1 Control Panel Gentexl is a trademark of Gentex Corporation.
1 Hardware pack
6 EOL resistors(2.21 kQ P/N:25899) Ordering Information
-
Note: The D7039 Multiplex Expansion Module must be D7024 Four-zone FACP with D7039 Multiplex D7024 and
ordered separately and is delivered in its own Expansion Module D7039
shipping box. D7024LC Four-zone FACP with D7039 Multiplex D7024LC and
Expansion Module without Enclosure D7039
D7024-CD Reference CD D7024-CD
D7024-CD Reference CD
Order Number D7024-CD
The D7024-CD Reference CD provides literature related to the
D7024 Control Panel and its compatible products all on one
CD.
Series Photoelectric
Smoke Detectors SYSTEM
,R
Models Available
Two-Wire Models
2W-B 2-wire standard - 1
2WT-B 2-wire standard with thermal
Four-Wire Models 400
4W-B 4-wire standard
4WT-B 4-wire standard with thermal
Accessories "
2W-MOD 2-wire loop test/maintenance module
SENS-RDR Sensitivity reader •�'
RT Removal/replacement tool
A77-AB2 Retrofit adapter bracket
r
Product Overview
Plugin detector line-mounting base System Sensor's 13"series smoke detectors represent a significant advancement in
included conventional detection.The i3 family is founded on three principles: Installation
Large wire entry port ease, Intelligence, and Instant inspection.
In-line terminals with SEMS screws Installation ease.The i3 line redefines installation ease with its plug-in design.
This allows an installer to pre-wire the bases included with the heads. The large
Mounts to octagonal and single-gang wire entry port and in-line terminals provide ample room for neatly routing the
backboxes, "uare backboxes,or wiring inside the base.The base accommodates a variety of back box mounting
direct to ceiling methods as well as direct mounting with drywall anchors.To complete the
installation,i3 heads plug-in to the base with a simple Stop-Drop 'N Lock
Stop-Drop'N Lock-attachment to base action.
Removable detector cover and chamber Intelligence. i3 detectors offer a number of intelligent features to simplify
for easy cleaning testing and maintenance. Drift compensation and smoothing algorithms are
standard with the i3 line,to minimize nuisance alarms. When connected to the
Built-In remote maintenance signaling 2W-MOD loop test/maintcnance module, or a panel equipped with the i3
Drift compensation and smoothing protocol, 2-wire i3 detectors are capable of generating a remote maintenance
algorithms signal when they are in need of cleaning. This signal is indicated via an LED
located at the module and the panel. To read the sensitivity of i3 detectors,the
Simplified sensitivity measurement SENS-RDR is a wireless device that displays the sensitivity in terms of percent
per foot obscuration.
Wide angle, dual color LED indication Instant Insp
ection. The i3 series provides wide angle red and green LED indica-
Loop testing via EZ Walk feature tors for instant inspection of the detector condition,indicating: normal standby,
out-of-sensitivity, alarm,or freeze trouble conditions.When connected to the
Built-in test switch 2W MOD loop test/maintenance module or a panel with the i3 protocol,
the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature
U verifies the initiating loop wiring by providing LED status indication at each
MEA MSFM detector.
LISTED approved approved
U L
5 '
DA ' "'
ANI�EA SYS�EM1.S_ ► � � I '
Helping People Take ActionS"'
DESCRIPTION. SERIES RSSWP, ASWP, AHWP, MTWP
Wheelock's Weatherproof Strobe,Audible Strobe,Audible and MT-12/24
Horn and Multitone Strobe appliances have an extended
temperature range of-31'F to 150°F(-35`C to 66`C)that WEATHERPROOF STROBE
will satisfy virtually all outdoor and severe environment WEATHERPROOF AUDIBLE STROBE
applications. All strobes are Indoor/Outdoor UL Standard AND WEATHERPROOF AUDIBLES
1638 Listed and rated for 180 candela on axis @ 77°F
(25'C) and 75 candela at -31°F (35°C) with low current
draw.
The Wheelock Weatherproof Appliances are designed for w i SERIES MTWP
maximum performance, reliability, and cost effectiveness Mounted to IOB-R
while meeting or exceeding the latest requirements of
NFPA 72 (National Fire Alarm Code), UL Standard 1638
(Standard for Visual Signaling Appliances), and UL _
Standard 464(Standard for Audible Signaling Appliances).
Series RSSWP Strobes,Series ASWP Audible Strobes and SERIES RSSWP
Series AHWP Audibles may be synchronized when used Mounted to WPSBB-R -
in conjunction with the Wheelock SM and DSM Sync
Modules or the PS-12/24-8CP and PS-12/24-8MP Power
Supplies with Patented Sync Protocol. The Series MTWP
is a true 4-wire appliance. The strobe portion can be r {�
synchronized as stated above. The multitone portion ■ SERIES AHWP
cannot, but it can be connected to a coded fire alarm _ Mounted to WBB-R
system. t-
�tti�
Weatherproof Strobe Series RSSWP I
Is UL Standard 1638 approved for Indoor/Outdoor use. '"k "''
The appliances use a Xenon flashtube with solid state �
circuitry enclosed in a rugged Lexan@ lens to provide SERIES ASWP
maximum visibility and reliability for effective visual Mounted to WPBB-R --f -
signaling. The Series RSSWP mounts to a Series WPSBB
Weatherproof Backbox. Features `
Weatherproof Audible Strobe and Audible SPriPS a Approvals include: UL Standard 1638 and 464, California
ASWP and AHWP State Fire Marshal(CSFM)and New York City(MEA),
Is UL Standard 1638 and UL Standard 464 approved for Factory Mutual(FM)and Chicago(BFP)See approvals by
Indoor/Outdoor use and offer a field selectable choice of model in Table 8
continuous horn or temporal pattern (Code 3) when a Designed to meet or exceed NFPA,/UFC/ANSI 117.1/
constant voltage from the Fire Alarm Control Panel(FACP) OSHA Part 29, 1910.165, and ADA requirements
is applied. Additionally,the audible has three(3)selectable
dBA settings of 99, 95, and 90 dBA in both tones and, a UL Standard 1638 and UL Standard 464 listed with
when synchronized, may be silenced while maintaining extended temperature range of-31°to 150°F(-35°C to
strobe activation. The Series ASWP mounts to a WPBB 66°C)
Weatherproof Backbox while the Series AH mounts to a a 24 VDC with new UL"Regulated"Voltage Range:of
WBB Weatherproof Backbox. 16-33 VDC using filtered DC or unfiltered FWR voltage
Weatherproof Multitone Strobe and Multitone Horn Note: The Series MT-12/24 voltage range is 10.5-15.6
Series MTWP and MT-12124 VDC(for 12V)and 20-31 VDC(for 24V)
Is UL Standard 1638 and UL Standard 464 approved for a Sync/Non-Sync in each product. Note: The audible
Indoor/Outdoor use and offers a field selectable choice portion of the Series MTWP and MT-12/24 is non sync
of 8 nationally and internationally recognized alerting only
signals. Additionally,the audible has 2 installer selectable a Synchronize with Series SM, DSM Sync Modules or PS-
sound output levels: Standard and high covering a range 12/24-8CP and PS-12/24-8MP Power Supplies with
(depending on selected signal)of 76-94 dBA reverberant. built-in patented sync protocol
The Series MTWP is a true 4 wire appliance. The Strobe
portion can be synchronized or non-synchronized. The a Selectable dBA settings
multitone (audible) portion cannot be synchronized, but it a Selectable alert signals
can be connected to a coded fire alarm system. The Series a IN and OUT wiring termination that accepts two#12-18
MTWP and the MT-12/24 mount to a series 1013 Backbox. AWG wires at each terminal
Inputs are polarized for compatibility with
Copyright 2004 Wheelock,Inc.All rights reserved. industry standard reverse polarity supervision
Wiring Diagrams STROBE OPERATION WITH CODED FACP
MP"
m-
SERIESMTWPAUDIBLEAPPLIANCEAND STROBE OPERATE Sync o- B �i
INDEPENDENTLY NAC#1 -0 MO&JIO
1-0 or
o Audbk
FROM TO NEXT POD C.ftt
AUDIBLE OR
PRECEDING ♦ ♦ AUDIBLE OR FACP supply —0
_
FACP EOLR
FROM NAC#z�
PRECEDING + ♦ TO NEXT 0-
STROBE OR
STROBE OR EOLR Note: Strobe circuit requires constant voltage.
FACP
♦— 0 ♦— SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/
STROBE AUDIBLE DSM MODULE SINGLE CLASS"A"NAC CIRCUIT
DSM
STROBE SERIES MTWPAUDIBLE APPLIANCE AND STROBE OPERATE IN NAC SYNC+ 00
R
UNISON.REDAND BLACK SHUNTWIRESARE SUPPLIED. CIRCUIT '
0 0 oUr
+IN 1 Parsw R,%
FROM M01
PRECEDING + + APPLIANCE FACP \
APPLIANCE aeo +AUDIBLE
BLACK OR EOLR
OR FACP MINUS2
+IN 2 RSS ^'+' jt$$
21 m 121 t2l TROBE
+ - 0 + - NAC
srRoee AuoieLe CIRCUITRETURN
SERIES RSSWP,ASWP,AHWP,MTWP AND MT-1 2/24 SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED
APPLIANCES WITH MULTIPLE DSM MODULES CLASS`B"NAC CIRCUITS
FROM + + TO NEXT
PRECEDING DSM#1
APPLIANCE
APPLIANCE OR OR EOLR Sync
FACP Strobe NAC Cir. 0+ RS"VW RSS
do F
' 0
+ -
A DSM#2
Strobe NAC Cir rSyyn 5WP RS6WP
C DSM#3
PjE3]j,
Strobe NAC Cir RsswP
DSM Interconnecting wiring shown. Maximum of
twenty(20)
Order Strobe cd Strobe cd Outdoor
Model Number @ 77°F @-31°F dBA Input MountingBack Box 8 Agency A
Code (25°C) (-35°C) Voltage Order Code g Y Approvals
Options#
Strobe UL MEA CSFM FM jBFP
RSSWP-2475W-FR 9013 180cd 75cd - 24 VDC T WPSBB-R(9751) X X X X
RSSWP-2475W-FW 3034 180cd 75cd - 24 VDC T WPSBB-W(3033) X X X X
.Audible Strobe
ASWP-2475W-FR 9012 180cd 75cd 90/95/99 24 VDC I WPBB-R(9014) X X X X X
Multitone Strobe
MTWP-2475W-FR 8420 180cd 75cd 76-94 24 VDC M IOB-R(5046) X X X X
Horns/Audibles
AH-24WP-R 7416 N/A N/A 90/95/99 24 VDC K WBB-R(2959) X X X - X
AH-12WP-R 7415 N/A N/A 90/95/99 12 VDC K WBB-R(2959) X X X - X
MT-12/24-R 5023 N/A N/A 76-94 12/24 VDC M IOB-R(5046) X X X X X
Speaker Strobe
ET70WP-2475W-FR 9077 180cd 75cd 77-93 24 VDC M IOB-R(5046) X X X '
For more information on the ET70WP Appliance,see Specification Sheet S9006.
9"71-
City of Arlington
Development Services
Permit Center
REQUEST FOR REVIEW
NAME: t- BP #: 06-
DATE: RETURN THIS FORM BY: lot,
PROJECT SUMMARY: ,
RESPONDING DEPARTMENTS
ATOM C., FIRE DAVE A. BUILDING
KAREN L., UTILITIES KERRY W., BUILDING
DERYL T., MARYSVILLE UTIL \,SCOTT B., BUILDING
BILL B., NATURAL RESOURCE YVONNE P., PLANNING
GREGG E., ENGINEERING CWA., CONSULTANT
SHERRI PHELPS, BUS LIC �JIM T., CONSULTANT
SUBMITTAL INFORMATION IS ATTACHED. Please review the information and return this form and your
comments in memo form. If you have no comments, please return the form with the"No Comments" box
checked.
PLEASE MARK ONE BOX, SIGN, DATE, AND RETURN THIS FORM TO PC
c�
Q' ❑ COMMENTS FOR THIS REVIEW ARE IN ATTACHED MEMO
❑ NO COMMENTS FOR THIS REVIEW, OKAY TO ISSUE PERMIT
P ❑ COMMENTS
REVIEWED BY DATE
RECEIVLso
COA P'ERIWiT(jchI rr,
City of Arlington
ob
n
r-an
Development Services
Permit Center
REQUEST FOR REVIEW
NAME: BP #: 06-
DATE: 3LI 0L� RETURN THIS FORM BY: �
PROJECT SUMMARY:
RESPONDING DEPARTMENTS
ATOM C., FIRE DAVE A. BUILDING
KAREN L., UTILITIES KERRY W., BUILDING
DERYL T., MARYSVILLE UTIL �SCOTT B., BUILDING
BILL B., NATURAL RESOURCE YVONNE P., PLANNING
GREGG E., ENGINEERING CWA., CONSULTANT
SHERRI PHELPS, BUS LIC \JIM T., CONSULTANT
SUBMITTAL INFORMATION IS ATTACHED. Please review the information and return this form and your
comments in memo form. If you have no comments, please return the form with the"No Comments"box
checked.
PLEASE MARK ONE BOX, SIGN, DATE,AND RETURN THIS FORM TO PC
❑ COMMENTS FOR THIS REVIEW ARE IN ATTACHED MEMO
NO COMMENTS FOR THIS REVIEW, OKAY TO ISSUE PERMIT
'Fe7u0,A1 0-91. AO-PrLO11 A-t--
❑ COMMENTS
REVIEWED BY ( t ( DATE
EOL
EOL
EOL
EOL EOL
TO 120 VAC UNSWTCHED
DEDICATED CIRCUIT
FACP l70 TELCO ROOM
FIRE ALARM RISER DIAGRAM
SCALE: NONE
r--SEE ENLARGED
PLAN, THIS SHEET
EQUIPMENT LEGEND
FT L—__J DVM CC QUANTITY PART NUNMSER DESCRIPTION SACKBOX
SYNBCL
® 1 07024 FIRE ALARM CONTROL PANEL INCLUDED
FLOOR PLAN ® 1 2WB SMOKE DETECTOR 4 SCUARE X 1-7/8" DEEP
aD SCALE: 1/32"=1'-O' 00 1 ASWP WEATHERPROOF HORN STROBE INCLUDED
m 1 -- SPRINKLER LOW AIR SWITCH-
® 1 -- SPRINKLER TAMPER SWITCHO --
® 1 -- SPRINKLER WATER-FLOW SWITCH-
PROVIDED AND INSTALLED BY OTHERS
WIRE LEGEND
TYPE DESCRIPTION
A 18 AWG, 2 CONDUCTOR 'FPUP' JACKETED CABLEI
B 14 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLEI
C 18 AWG, 4 CONDUCTOR 'FPLP' JACKETED CABLEI
GENERAL NOTES:
1,ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS,
2.WIRING METHOD ISTO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND
BELOW SEVEN FEET-THEN IT IS TO BE IN CCNOUR
3.ALL JUNCTION BOXES,COVERS,AND BACK BOXES ARE TO BE PAINTED RED,
4.PULL STATIONS ARE TO BE MOUNTED AT 4e'TO 53'ABOVE THE FLOOR
B.ALL INDOOR HORNS,STROBES,HORN STROBES,AND MINI HORN STROBES ARE
Rni�1 TORE MOUNTED 80'ABOVE THE FLOOR ORS'BELOW THE CEILING,WHICHEVER IS
LOWER.
W 8.SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE RH THE
B FOLLOWING:
AT A)36'INCHES AWAY FROM ANYAIR HANDLING SYSTEM DIFFUSER
B)NOT INCLOSE PROXIMITYTOANY FLUORESCENT LIGHT FIXTURES
7,EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE
WALL OF THE BUILDING,AS HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE
FIRE DEPARTMENT ACCESS ROADWAY.
y S.ALL WIRING PENETRATINOANY FIRE RATED BARRIER SHALL BE SEALED WTTH
,gYgP MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES
A
LA TS
D
sEOL EOL EOL FIRE COM NW LLC
PO Box 3932 Seattle WA 981243932 206-234.5700
DATE: 02/2W06 PROJECT NNIJE,
DRAWN: CEA JOHNSON HANGAR
S CHECKED: JD 1891459th Or.NE-AdingtonAlrport
AryIgton,LVVA
ENLARGED FIRE ALARM PLAN APA�REMED BY. AS NOTED
a I \ SCALE: 1/4"-1'-D' ALARM PLAN
N0. DATE REVISION BY FIRE
l/
JOB NUMBER: 06-039 FA-1 of
"
i
5 4°11'40° E
(()
n
CI \
i r r >I €
f if D t
UN
�
n�y O \
� - -
sn -tt(JN j\ z
1' clt -t
�--.i 1 _— — -.' - -_:._. _S� } - -. —_ O -<n to ,_._.,•-. Z _ .,
ul
13
vrn}
$ r'
F �V
rr l
-t
'aJj a
5 4
1 c n
r I c urn A --- -� .. - s_ ;; ❑I ( _ r..____ �',.i l O t
Qp
�1
ni 4q -4b 0„
„
g N N
>En m�[vri:N�
i
p .g
g a Y�
�„
_-
r c
v`
O I f V D C it O _ - __ - - •` Sll
.D.1 Z8Z L��y'11rN (gr5 p O\ - --}�•� 4 'j� I ,l
fii -1 'a Z.-i.O Q1Id�O -• -6'll - � Ci 4._. � �� � '\L
Ek -0
m
E
A W N 0-•yy P W A W N �y -- - Opku
N - _�\.\_ .- L _(._ _�❑ ( (j-l.�l
(y"'g � /yam z_ o a'-o^
�q
rMgxp$�'i � �0-� 21 !�
�Z� � y70
� U, 5gth DRIVE NE
SKI• + �� '� (jl T p 2 C LD
CrnS� �6 Cp rNnt
Ll
> LL L—Lt]11 F
FAR. ��
—LL
2- � r�i O L��IS a .4 r.i �3ft Q Y P y� 1
� �• �j �
rrr m 3
—ra
P.. 3 CPf1i.c,c,N WD pW pW_W_W
5I I O II OIL 6` iZT li 9D C� NN W N i A "ti TI
SMOKEY FT.
51 st Ave
0
RI
54th Dr i ve
i k `
_ DATE: REVISIONS:
A NEW AIRCRAFT HANGAR BUILDING FOR: � � r /� {,,
►� V� m r z ' �T Ec \ \: Gary Parkins®n Architects q/26/05 I55UE FOR BLP6. PERMIT
n y" r ��� �� �nac rEcr II/Ib105 REV. PER PERMIT REVIEY� GOMM�iS
�j �, 2812 COLBY AVE EVERETT, WASHINGTON 98201
Z 2 .� .� .�._ f (425)252-2153 FAX(425)742-8130 12/2q/05 I55UE FOR W5DOT Rev icy,
mo p y m �� 59th DRIVE NE s; w
`' ~' ARLINGTON,WASHINGTON