Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18032 GREYWALLS DR_077493_2026
City of Arlington (41N Community Development GO Permit Center REQUEST FOR REVIEW NAME: BP #: 07 Jyg3 DATE: -7 - "° -7 RETURN THIS FORM BY: -7 -16-o l PROJECT SUMMARY: raj, oti-s,a,.Q �, o Ao1" ; c�.� r:ESP"`�JC�"�G r-,F_PA F:TK LENT - INN v� i--, . i IVI i i J TOM C., FIRE DAVE A., BUILDING UTILITIES KERRY W., BUILDING BILL B., NATURAL RESOURCES SCOTT B., BUILDING ENGINEERING YVONNE P., PLANNING SHERRI PHELPS, BUS LIC CWA., CONSULTANT DERYL T., MARYSVILLE UTIL JIM T., CONSULTANT SUBMITTAL INFORMATION IS ATTACHED. Please review the information and return this form and your comments in memo form to the Permit Center. If you have no comments, please return the form with the "Okay to Issue" box checked. PLEASE MARK ONE BOX, SIGN, DATE, AND RETURN THIS FORM TO THE PERMIT CENTER. ❑ COMMENTS FOR THIS REVIEW ARE IN THE ATTACHED MEMO L] NO COMMENT FOR THIS REVIEW, OKAY TO ISSUE PERMIT ❑ COMMENTS REVIEWED BY _DATE I �' �� �7�� �� ��� (A,1�� V 1 f y �J VVV - � �- - . �. �- . .� -- y..��:Q.. ��.�,;tip �,.. ._ '-' -- --� _ . �. � . RESIDENTIAL MECHANICAL C,7PERMIT APPLICATION 'INC' Department of Community Development City of Arlington• 238 N Olympic Ave. •Arlington,WA 98223 • Phone(360)403 3551 • FAX(360)403 3447 THIS APPLICATION TO BE USED FOR ONE AND TWO DWELLING UNITS RESIDENTIAL STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3)SETS OF CONSTRUCTION DRAWINGS,AND THREE(3) SETS OF WASHINGTON STATE ENERGY CODE APPLICATIONS. 55214Nx 03� Type of Permit: ( ) Residential Project Valuuaation: /� �Y)� 'yyy Project Address: r " //r Parcel ID#: Cti� 7-6 Lot#: Subdivision: Project Description:- Owner: l'C C' �s����� t� Phone Number: Address: 25 +JJ�v�' y� V ��S City: ��n °r State: �'[`' Zip Code: qeZZ3 Contact Penton:om5 � � J�r Phone Number: Cell Phone: F �"' '� FZ3 4049E-mail. &t2�5 Address: 1-3 o, City: State: Zip Code: � :I Please List quantity C C of fixtures Below: A Ili -l-0f PCYZC'--- CLOTHES DRYER FURNACE UP TO 100K BTU GAS OUTLETS FURNACE OVER 100K FLR FURN INSTALL/RELOCATE SUSPENDED HTR/UNIT HTR\ APPL VENT/OTHER APPLIANCE REPAIR BOILER UP TO 3 HP BOILER UP TO 4-15 HP BOLIER UP TO 16-30 HP BOILER UP TO 31-50 HP BOILER 51 HP AND UP AIR AHNDLING UP TO 10K CFM AIRHANDLING OVER 10K CFM EVAL COOLER VENTILATION FANS OTHER VENTILATION SYSTEM VENT HOOD DOMESTIC INCINERATOR COM/IND INCINERATOR ALL OTHER UNITS FREESTANDING STOVE FIREPLACE INSERT Contractor: n Phone Number: (IRa5 Address: City. State: Zip Code: Contractor's License Number: 5 7 ) 0, Expiration: q z I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington. Appii nts Signature Date Print Applicants Name FOR STAFF USE ONLY A 0 Permit# Accepted By Amount Received Receipt# Date Received WEB Forms-42 Page 1 of 1 3/07 dwa i v J+1 cL /'E!ADC0 SUPPLY Heating&Cooling Systems Since 1904 N/W Distributors Heating and Cooling Products 41 KENT SPOKANE 7915 SOUTH 184th St. 730 E. FIRST AVENUE KENT,WA 98032 SPOKANE,WA 99202 (425)251-9741 (509)536-1811 1-800-922-1943 FAX(425)656-0121 FAX(509)535-0582 �,(Z S 766 s- "70 DE. XE 12 SEER 552A AIR CONDITIONER Heating&Cooling Systems WITH PURON° REFRIGERANT Sizes 018 thru 060 ram' on production of most other refrigerants which has scheduled reductions beginning in 2004. The resulting cap in production ultimately results in a complete ban on many other refrigerants in new equipment by the year 2010.These changes,required by 044 federal law,mean the supply of other refrigerants may be limited in the near future making Puron the correct choice when consid- ering long term serviceability. Highly Reliable Performance—Is delivered through the supe- rior design of the system and componentry.The reliability of the 552A model has been proven to provide the lowest inci- dence of warranty service of any product in the Bryant family in the past few years of service. Long terrn reliability is assured through the use of both high and low pressure � ! switches which will not allow the system to operate in the k event of a significant change in operating pressure. In doing this, the system is protected from damage if an unusual condi- tion arises. Finally, Bryant includes a special liquid line filter drier designed to trap moisture and contaminants which could otherwise shorten the life of the system. Preferred Bryant's AeroQuiet System—Extremely low operating sound is the result of special attention to the air moving through the outdoor Bryant's Air Conditioners with Puron® refrigerant provide fea- unit, and a specially designed sound enclosure surrounding the lures unmatched by any other family of equipment.The 552A is compressor to eliminate sound transmission to the rest of the sys- an air conditioning system utilizing Bryant's Puron refrigerant. terns. The environmentally sound refrigerant allows you to make a Application Versatility—Bryant's systerns utilizing Puron responsible decision in the protection of the earth's ozone layer. refrigerant have the same application guidelines as other sys- Bryant's 552A systems meet the Energy Star° guidelines for tems.Applications which include long line sets(50 to 175 ft)or energy efficiency. applications which require the system to operate at low outdoor FEATURES temperatures (below 55°F) are approved under Bryant's stan- Puron® Environmentally Sound Refrigerant—Is Bryant's dard guidelines. refrigerant designed to help protect the environment. Puron is Bryant Coils and Fan Coils to Complete the System—Bryant an HFC refrigerant which does not contain chlorine that can specially designs both the outdoor product and indoor coil prod- harm the ozone layer.The most important advantage of Puron ucts to operate with assured reliability and performance.A wide refrigerant is that it has not been banned in future air condition- range of indoor coil options are listed in the ratings section of ing systems as the traditional refrigerant R-22 has been. Puron this publication. refrigerant is in service in thousands of systems proving highly Special Protective Devices—High and low pressure switches reliable,environmentally sound performance. and internal protection in the compressor including temperature Bryant's Evolution*"' Controls—These industry-leading con- and current sensing overloads prevent operation under poten- trols, when installed with Bryant's Perfect HumidityT"' variable- tially damaging circumstances. A special liquid line filter drier speed furnaces or fan coils,provide the homeowner with: designed to trap nearly four times the volume of contaminants of —unparalleled control of temperature,humidity,indoor air quality, standard driers provides superior protection from moisture and zoning trapped in the system. —unprecedented ease of use Electrical Range-208/230v,single phase. —simple operation through on-screen, text-based service reminders Wide Range of Sizes—Available in seven sizes;1-1/2,2,2-1/2, Optional remote access through telephone or Internet is also 3,3-1/2,4,and 5 tons. available when combined with a remote connectivity kit. Cabinet—Galvanized steel is coated with powder paint to pro- Heavy Duty Inlet Grille—The DuraGuardTM coil protector, vide a superior,long lasting appearance. made of a coated steel wire grid with vertical 3/8 in.spacing, is Totally Enclosed Fan Motor—Protected from adverse weather designed to help protect the coil from inclement weather, van- conditions. dalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and Unit Design—Enhanced copper and aluminum heat transfer cleaning. surfaces with vertical air discharge to direct air up and away High Efficiency Performance—Is delivered through a combina- from the area. tion of features including Bryant's Puron refrigerant,unique scroll External Service Valves—Both service valves are back seating compressor, and advanced heat transfer surfaces.Efficiency ral- type valves which are externally located.These unique valves ings are 12 SEER (Seasonal Energy Efficiency Ratio) with allow service technicians to evacuate or charge the system in enhanced ratings of up to 14 SEER. Sophisticated heal transfer less time than standard service valves. surfaces utilized in Bryant's 552A design allow heat to easily be Easy Serviceability—One access panel provides access to transferred the outdoor air and require less energy.The unique electrical controls and compressor.Removal of wire dome gives scroll compressor ssor found in the A design performs quietly and access to fan motor and removal of the top gives access to the adds to the overall efficiency of the the system.For improved service- coil. ability,all models are equipped with a compressor terminal plug. Finally, Bryant's unique Puron refrigerant operates more effi- Agency Approvals-552A models are listed with UL (U.S.and ciently than ordinary R-22 refrigerant found in other systems.The Canada),ARI,and CEC.Special endorsements have also been efficiency levels provided by the 552A provide end users with awarded these products by Energy Star@ which recognizes lower costs of operation than traditional air conditioning systems. energy efficient products. Assured Future Service—By utilizing the environmentally Limited Warranty—A standard five year warranty on parts with a sound refrigerant, Puron, 552A models will remain.serviceable 10 year warranty on the compressor. Optional warranties are well into the future.The Clean Air Act of 1990 has placed a cap t1iI4blq Vpug }r5ur Bryant distributor. lia Form No. PDS 552A.18.5 �, 2 .F;�' hYll 0 C_V*4�Krc E 0 JUL DIMENSIONS (n z oo_ � _Z I� r N N N N N N F Z N M M co m CY) Z W X X X X X X X Z 3 N N N N N N N 0 a 0o m m N W Z c� c? UZ 0 N N pa N N N N N N N V of �- (2 M M Q m�H —4 J Z) Z O 1—2— J v v M I? M M d) Z U p =O Z ~ Q W �QU Z O aoz O - ¢ fr m Z T W N N N N N N V Wr¢ f—LL— O Q co Y c� _❑ (O N N 00 w w W � LC ai m W m Z ¢ o H d n aw p J O 5 Z O Lo W u x¢ o o >Z z w d p co co co co co co co U9 1'¢ OpmillO O M❑O ❑ (h M M M M M J- Z W m LL cO H N W �D aD aD W oD a ZJ m J Q (/� L Z LL Nf� a pp ZD LL ❑ v Z Z_ � w � ❑ J N 2 F O Z W p X LL �� + • � wRQO .-. N -0 � z �t 0 Z O Z w ❑ N ❑ m Z w N e _ w cn Ln VJ Z W 00 00 OD OD N W N m ❑ O Z W aq C7 " M M M C7 I7 W V ❑ L d 0 G f� N N N N V 00 N N N N N N M (5 \ > zQp , Cl) F ¢ oC Q C7 V N f W❑ Z W W 7 (z N (R fR (O fD (D oO U o F LL in Q w U' d OZ Z � W ZO ~ N N QrG O Q Q — c0 LO (2 (R (2 Z JLL, ❑ Q LL W 3 — ^ .- .�- O U Z O (n LL W y o 0 0 J W p ~p Y—�LLJ M r Cn U7 o g G I fn O LLI W W w to co cc co co LJ J ❑ c Z Z W W O r � 7 W-` O Q (n L j(!� U N Lo Lo F- U-j N Uf \ Z N M N N 7 7 N N 0 N N Z Z m O O O O O Q Q N N J m co m co co co co Q pw c7 r7 N N N N rl CE < cc ¢ 2 = U p 0 fCl)Z w W— p CC LL (D LL (� w LL LL cc: ¢ W ¢ ¢ Q co, F W 00 V O (D N aD O z N o 0 0 0 0 0 0 7 cn —2— r . I I RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter(In.) Vapor Tube Diameter(In.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 018 5/8 3/4 024 5/8 3/4 030,036 3/8 3/8 3/4 7/8 042,048 1 7/8 1-1/8 060 1 1-1/8 1-1/8 * For tube sets greater than 50 ft horizontal and/or 20 ft vertical differential, consult Application Guideline and Service Manual—Air Conditioners and Heat Pumps Using Puron®Refrigerant. CHECK-FLO-RATERO PISTON CHARGING SUBCOOLING (T,XV TYPE UNIT SIZE—SERIES IDENT FI CSTO AT ON NO. EXPANSION DEVICE*) 018 F 49 UNIT SIZE—SERIES REQUIRED SUBCOOLING(°F) 024-G 55 018 F 10 030-F 63 024-G 10 036-G 67 030-F 11 042-F 76 036-G 11 048-F 80 042-F 9 060-F 90 048-F 10 * Piston listed is for any approved non-capillary tube coil combina- 060-F 11 tion.Piston is shipped with outdoor unit and must be installed in * Must be a Puron®approved hard shutoff TXV. an approved indoor coil. MODEL NUMBER NOMENCLATURE 552A N X 018 000 A A AA T Model Number N/A Standard Unit 12 SEER Split-System Air Conditioner Electrical Supply Series A—Original Series N—208/230-1-60 Series B—Second Series,etc. Nominal Cooling Capacity 018—1.5 ton 042—3.5 ton Common Unit—U.S.A.Only 024—2 ton 048—4 ton 030—2.5 ton 060—5 ton 036—3 ton Heating Size Ga���o1 C o r o�a'o' BSI APPROVALS C IS0 9001 � C o u V - e' ir>a EN 29001 a oNrww PART 1 AN P �Yr AN5IIAS1/ASUC 091 * As an ENERGY STARo s0gOpf lP2q partner,Bryant Heating& CERTIFICATE NO.FM 28768 CERTIFICATION APPLIES ONLY Cooling Systems has REGISTERED QUALITY SYSTEM determined that this prod- WHEN THE COMPLETE SYSTEM uct meets the ENERGY IS LISTED WITH ARI. STAR®guidelines for energy efficiency. *Refer to the combination ratings in the Product Data Sheet for system combinations that meet Energy Star@ efficiency standards. -3- SPECIFICATIONS UNIT SIZE-SERIES r : rr Operating Weight(Lb) 168 1 209 209 212 ELECTRICAL Unit Volts—Hertz—Phase 208/230-60-1 Operating Voltage Range" 187-253 Compressor—Rated Load Amps 10.3 12.8 14.7 15.4 Locked Rotor Amps 51.0 60.0 72.5 83.0 Condenser Fan Motor—Full Load Amps 0.50 0.80 0.80 0.8 Min Unit Ampacity for Wire Sizing 13.4 16.8 19.2 20.1 Min Wire Size(60°C Copper)AWGt 14 14 14 12 Min Wire Size(75°C Copper)AWGt 14 14 14 12 Max Wire Length(Ft)(60°C Copper)$ 61 46 41 62 Max Wire Length(Ft)(75°C Copper)$ 58 44 39 59 Max Branch Circuit Fuse or Circuit Breaker Size(Amps) 20 25 30 30 COMPRESSOR&REFRIGERANT Compressor—Type Scroll Temperature&Current Protection Internal Line Break Refrigerant—Type Puron®(R-410A) Amount(Lb) 5.22 1 5.20 5.19 5.43 CONDENSER • Coil Face Area(Sq Ft) 10.9 10.9 12.2 12.2 Fins per In.—Rows—Circuits 25-1-2 25-1-2 25-1-2 25-1-2 Fan Motor—HP(PSC)&RPM 1/12&1100 1/10&1100 1/8&825 1/8&825 Volts—Hertz—Phase 208/230-60-1 Condenser Airflow(CFM) 1700 2000 2400 2400 OPTIONAL EQUIPMENT Support Feet KSASF0101AAA KAACF0801 MED/ Coastal Filter KAACF0701SML KAACF0701SML I KAACF0801MED Time Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist—Capacitor/Relay Type KSAHS1501AAA Start Assist—PTC Type KAACS0201 PTC TXV(Hard Shutoff) KSATX0201PUR KSATX0301PUR Piston Body KSAPX0101PIS Filter Drier(Suction Line) KH45LG140(RCD) Evaporator Freeze Thermostattt KAAFT0101 AAA Liquid-Line Solenoid Valve KAALS0201LLS Winter Start Controltt KAAWS0101AAA Low-Ambient Pressure Switch KSALA0301410 MotorMaster®Low-Ambient Controller— KSALA0401AAA Ball Bearing Fan Motor HC34GE232(RCD) HC38GE231(RCD) ThermidistatTM Control— Programmable Thermostat with Humidity Control TSTATBBPRH01-B Thermostat—Auto Changeover, 7-Day Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATBBPAC01-B Thermostat—Auto Changeover, Non-Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATBBNAC01-B Thermostat—Manual Changeover 5-2 Day Programmable,°F/"C, 1-Stage Heat,1-Stage Cool TSTATBBSAC01 Builder's Thermostat—Manual Changeover, Non-Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATBBBAC01-8 Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder's Thermostat TSTATXXBBP01 Backplate for Standard Thermostat TSTATXXSBP01 Thermostat Conversion Kit(4 to 5 wire}-10 Pack TSTATXXCNV10 Evolution Controls See Chart See notes on page 5. -4- SPECIFICATIONS Continued UNIT SIZE-SERIES 042-F r-: Operating Weight(Lb) 213 215 278 ELECTRICAL Unit Volts—Hertz—Phase 208/230-60-1 Operating Voltage Range* 187-253 Compressor—Rated Load Amps 18.6 20.5 27.6 Locked Rotor Amps 105.0 109.0 158.0 Condenser Fan Motor—Full Load Amps 1.1 1.1 1.4 Min Unit Ampacity for Wire Sizing 24.4 26.7 35.9 Min Wire Size(60'C Copper)AWGt 10 10 8 Min Wire Size(75'C Copper)AWGt 10 10 8 Max Wire Length(Ft)(60'C Capper)$ 81 74 86 Max Wire Length(Ft)(75'C Copper)$ 77 71 82 Max Branch Circuit Fuse or Circuit Breaker Size(Amps) 40 40 60 COMPRESSOR Compressor—Type Scroll Temperature&Current Protection Internal Line Break Refrigerant—Type PuronO(R-410A) Amount(Lb) 5.43 5.75 1 8.00 CONDENSER • Coil Face Area(Sq Ft) 12.2 12.2 18.2 Fins per In.—Rows—Circuits 25-1-2 25-1-2 25-1-3 Fan Motor—HP(PSC)&RPM 1/5&825 1/5&1100 1/4&1100 Volts—Hertz—Phase 208/230--60-1 Condenser Airflow(CFM) 2800 2800 3300 OPTIONAL EQUIPMENT Support Feet KSASF0101AAA Coastal Filter KAACF0801MED Time Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist—Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist—PTC Type KAACS0201 PTC TXV(Hard Shutoff) KSATX0301PUR KSATX0401PUR KSATX0501PUR Piston Body KSAPX0101PIS Filter Drier(Suction Line) KH45LG141(RCD) Evaporator Freeze Thermostattt KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0201 LLS Winter Start Controltt KAAWS0101AAA Low-Ambient Pressure Switch KSALA0301410 MotorMaster®Low-Ambient Controller* KSALA0401AAA Ball Bearing Fan Motor HC38GE231(RCD) HC40GE232(RCD) ThermidistatT1A Control— Programmable Thermostat with Humidity Control TSTATBBPRH01-B Thermostat—Auto Changeover,7-Day Programmable, 'F/'C,1-Stage Heat,1-Stage Cool TSTATBBPAC01-B Thermostat—Auto Changeover,Non-Programmable, *F/'C,1-Stage Heat,1-Stage Cool TSTATBBNAC01-B Thermostat—Manual Changeover,5-2 Day Programmable,'F/'C,1-Stage Heat,1-Stage Cool TSTATBBSAC01 Builders Thermostat—Manual Changeover, Non-Programmable,'F/'C, 1-Stage Heat,1-Stage Cool TSTATBBBAC01-13 Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder's Thermostat TSTATXXBBP01 Backplate for Standard Thermostat TSTATXXSBP01 Evolution Controls See chart * Permissible limits of the voltage range at which the unit will operate satisfactorily.Operation outside these limits may result in unit failure. t If wire is applied at ambient greater than 30'C(86'F),consult Table 310-16 of the NEC(ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable(NM),trade name ROMEX,shall be that of 60'C(140'F)conductors,per the NEC(ANSI/NFPA 70)Article 336-26.If other than uncoated(non-plated),60 or 75'C(140 or 167'F)insulation,copper wire(solid wire br 10 AWG and smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the NEC(ANSI/NFPA 70). t Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. * Fan motor with ball bearings required. tt See low-ambient controller Installation Instructions for application. N/A—Not Applicable. NOTE:Copper wire must be used from service disconnect to unit.All motors/compressors contain internal overload protection. -5J- EVOLUTIONTM*CONTROLS DESCRIPTION ACCESSORY Evolution Control Deluxe 7-Day Programmable(Wall-mounted system control.) SYSTXBBUID01 Z Evolution Zone Control Deluxe Zoning 7-Day Programmable(Wall-mounted control fora SYSTXBBUIZ01 O multi-zone system.) N Evolution 4-Zone Damper Control Module(Wall-mounted control for a four-zone system.) SYSTXBB4ZC01 Evolution Smart Sensor(Optional wall control used to monitor temperature and/or fan control SYSTXBBSMS01 N in an individual zone.) G Evolution Remote Room Sensor(Monitors temperature in an individual zone.) SYSTXBBRRS01 Evolution System Access Module(Hardware for wireless access and control via phone or SYSTXBBSAM01 internet.) Evolution Network Interface Module(Connects Heat Recovery or Energy Recovery Ventilators SYSTXBBNIM01t or older two-speed outdoor models to system.) Back Plate for Evolution Control(Decorative wall plate.) SYSTXXXBPU01 * When applied with Bryant's Perfect Humidity TM series 355,315 and FIE Indoor Models. t Must be installed in Dual-Fuel Evolution system applications. ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW-AMBIENT LONG-LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS ACCESSORY (Below 55°F) (Over 50 Ft) (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yest No No Accumulator No No No Compressor Start Assist Yes Yes No Capacitor and Relay MotorMaster@ Low-Ambient Controller or Yes No No Low-Ambient Pressure Switch Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve See Long-Line or No Application No Hard ShutoffTXV Guideline Ball Bearing Fan Motor Yes$ No No * For tubing line sets greater than 50 ft and/or 20 ft vertical differential,refer to Application Guideline and Service Manual—Air Conditioning and Heat Pumps Using Puron® Refrigerant. t Only when low-pressure switch is used. t Required for low-ambient controller(full modulation feature)and MotorMaster®Control only. ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when low-ambient controller(full modulation feature)or MotorMaster@--Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the tap cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist—Capacitor and Relay Start capacitor and relay gives a"hard"boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for scroll compressors in the following applications: Long line Low ambient Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist—PTC Type Solid state electrical device which gives a"soft"boost to the reciprocating compressor at each start-up. Usage Guideline: Suggested in installations with marginal power supply. —6— ACCESSORY DESCRIPTION AND USAGE(Continued) 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles.Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Liquid-Line Solenoid Valve(LLS) This device serves two purposes.It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor oper- ation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration. Note:When LLS is used with reciprocating compressors,Compressor Start Assist-Capacitor and Relay is required. Usage Guideline: Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration.A hard shut off TXV can be used instead of an LLS in single flow air conditioner applications.See Long Line Application Guideline. 8. MotorMaster@--Low-Ambient Controller A fan-speed control device activated by a temperature sensor,designed to control condenser fan motor speed in response to the saturated,condensing temperature during operation in cooling mode only.For outdoor temperatures down to-20°F(-28.9°C),it maintains condensing temperature at 100°F± 10°F(37.8°C±-12°C). Usage Guideline: A MotorMaster@--Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor tem- peratures below 55°F(12.8°C). Suggested for all commercial applications. 9. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication.This device enables the thermostat to display the outdoor temperature.This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Bryant thermostats listed in this publication. 10. Sound Hood Wraparound sound reducing cover for the compressor.Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft to quiet areas-bedrooms,etc. Suggested when unit is installed between two houses less than 10 ft apart. 11. Support Feet Four stick-on plastic feet that raise the unit 4 in.above the mounting pad.This allows sand,dirt,and other debris to be flushed from the unit base,minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 12. Thermostatic Expansion Valve(TXV) A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.Kit includes valve,adapter tubes,and external equalizer tube.Hard shut off types are available. Note:When using a hard shut off TXV with single phase reciprocating compressors,a Compressor Start Assist-Capacitor and Relay is required. Usage Guideline: Required to achieve ARI ratings in certain equipment combinations.Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications Required for use on all zoning systems. 13. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note:Most indoor unit controls include this feature. For those that do not,use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units.Refer to ARI Unitary Directory. A-WTD.SOUND POWER (dBA) UNIT STANDARD TYPICAL OCTAVE BAND SPECTRUM(without tone adjustment) SIZE-SERIES RATING 125 250 500 1000 2000 4000 8000 018-F 71 50.5 60.0 64.5 67.0 63.0 56.0 48.5 024-G 74 57.0 66.0 68.0 67.0 65.0 62.0 51.5 030-F 70 57.0 61.5 64.5 65.0 63.0 59.5 53.0 036-G 73 60.0 64.0 66.5 68.5 66.0 62.0 53.5 0427F 73 57.5 63.5 67.0 1 68.0 1 65.5 1 62.0 1 55.0 048-F 76 63.0 66.0 67.0 70.5 67.0 62.5 55.0 060-F 78 63.0 67.5 69.5 72.5 68.5 64.5 58.5 -7- COMBINATION RATINGS SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt Puron TXV$ EER *CK5A/CK5BA024 17,500 NONE - 12.00 12.00 10.80 CC5A/CD5AA018 17,200 NONE - 11.50 11.50 10.45 CC5A/CD5AA024 17,500 NONE - 12.00 12.00 10.70 CC5A/CD5AW024 17,500 NONE - 12.00 12.00 10.70 CE3AA024 17,500 NONE - 12.00 12.00 10.75 CF5AA024 17,500 NONE - 12.00 12.00 10.75 CK3BA024 17,500 NONE - 12.00 12.00 10.80 CK5A/CK5BA018 17,200 NONE - 11.50 11.50 10.60 CK5A/CK5BW024 17,500 NONE - 12.00 12.00 10.80 CK5PA018 17,200 TXV - 11.50 - 10.60 CK5PA024 17,500 TXV - 12.00 - 10,80 CK5PW024 17,500 TXV - 12.00 - 10.80 F(A,B 4(A,B)N(F,C 018 17,200 TDR 11.70 - 11.70 10.60 F(A,B;4(A,B)N(F,C)024 17,500 TDR 12.00 - 12.00 10.90 FC4(B,C)NF024 17,600 TDR&TXV 12.00 - - 10.90 FE4ANF002 18,000 TDR&TXV 13.50 - - 12.25 FFlDNA018 17,200 TDR 12.00 - 12.00 10.90 FFlDNA024 17,500 TDR 12.00 - 12.00 10.75 FG3AAA024 17,500 NONE - 11.70 11.70 10.60 FK4(C,D)NF001 17,600 TDR&TXV 13.00 - - 12.20 FK4(C,D)NF002 18,000 TDR&TXV 13.50 - - 12.25 FV4(A,B)NF002 18,000 TDR&TXV 13.50 - - 12.25 FX4(A,B)NF018 17,600 TDR&TXV 12.00 - - 10.90 COILS+315(A,J)AV036070 VARIABLE-SPEED FURNACE 018-F CC5A/CD5AA018 17,200 TDR. 12.50 - 12.50 11.60 CC5A/CD5AA024 17,500 TDR. 13.00 - 13.00 11.85 CC5A/CD5AW024 17,500 TDR. 13.00 - 13.00 11.85 CE3AA024 17,500 TDR 13.00 - 13.00 11.85 CK3BA024 17,500 TDR. 13.00 - 13.00 12.00 CK5A/CK5BA018 17,200 TDR 13.00 - 13.00 11.75 CK5A/CK5BA024 17,500 TDR 13.00 - 13.00 12.00 CK5A/CK5BW024 17,500 TDR 13.00 - 13.00 12.00 CK5PA018 17,200 TDR&TXV 13.00 - - 11.55 CK5PA024 17,500 TDR&TXV 13.00 - - 11.90 CK5PW024 17,500 TDR&TXV 13.00 - - 11.90 COILS+315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,500 TDR 13.00 - 13.00 11.85 CE3AA024 17,500 TDR 13.00 - 13.00 11.80 CK3BA024 17,500 TDR 13.00 - 13.00 12.00 CK5A/CK5BA018 17,200 TDR 13.00 - 13.00 11.75 CK5A/CK5BA024 17,500 TDR 13.00 - 13.00 1190 CK5A/CK5BW024 17,500 TDR 13.00 - 13.00 11.90 CK5PA018 17,200 TDR&TXV 13.00 - - 11.50 CK5PA024 17,500 TDR&TXV 13.00 - - 11.80 CK5PW024 17,500 TDR&TXV 13.00 - - 11.85 COILS+355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,500 TDR 13.00 - 13.00 11.75 CE3AA024 17,500 TDR. 13.00 - 13.00 11.80 CK5A/CK5BW024 17,500 TDR 13.00 - 13.00 11.90 CK5PW024 17,500 TDR&TXV 13.00 - - 11.90 *CK5A/CK5BA030 23,000 NONE - 12.00 12.00 10.70 CC5A/CD5AA024 22,800 NONE - 12.00 12.00 10.50 CC5A/CD5AA030 23,000 NONE - 12.00 12.00 10.60 CC5A/CD5AW024 22,800 NONE - 12.00 12.00 10.50 CC5A/CD5AW030 23,000 NONE - 12.00 12.00 10.60 CE3AA024 22,800 NONE - 12.00 12.00 10.60 CE3AA030 23,000 NONE - 12.00 12.00 10.70 CF5AA024 22,800 NONE - 12.00 12.00 10.50 CK3BA024 22,800 NONE - 12.00 12.00 10.65 CK3BA030 23,000 NONE - 12.00 12.00 10.70 CK5A/CK5BA024 22,800 NONE - 12.00 12.00 10.65 CK5A/CK5BW024 22,800 NONE - 12.00 12.00 10.65 CK5A/CK5BW030 23,000 NONE - 12.00 12.00 10.70 CK5PA024 22,800 TXV - 12.00 - 10.65 CK5PA030 23,000 TXV - 12.00 - 10.70 CK5PW024 22,800 TXV - 12.00 - 10.65 024-G CK5PW030 23,000 TXV - 12.00 - 10.70 F(A,B 48N(F,C)024 23,000 TDR 12.00 - 12.00 10.75 F(A,B3N(F,C)030 23,400 TDR 12.00 - 12.00 10.85 FC4CNF024 23,000 TDR&TXV 12.00 - - 10.75 FC4CNF030 23,400 TDR&TXV 12.00 - - 10.85 FE4ANF002 23,200 TDR&TXV 13.50 - - 12.05 FE4ANF003 23,600 TDR&TXV 14.00 - - 12.25 FFlDNA024 23,000 TDR 12.00 - 12.00 10.55 FFlDNA030 23.400 TDR 12.00 - 12.00 10.70 FFlDNE024 23,000 TDR&TXV 12.00 - - 10.55 FF1DNE030 23,400 TDR&TXV 12.00 - - 10.70 FG3AAA024 22,000 NONE - 11.50 11.50 10.35 FK4DNF001 23,000 TDR&TXV 13.50 - - 11.90 FK4DNF002 23,200 TDR&TXV 13.50 - - 12.05 FK4DNF003 23,600 TDR&TXV 14.00 - - 12.25 FV413NF002 23,200 TDR&TXV 13.50 - - 12.05 FV413NF003 23,600 TDR&TXV 14.00 - - 12.25 FX4BNF030 23,400 TDR&TXV 12.00 - 10.95 See notes on page 18. COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt PuronTXV$ EER COILS+315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,200 TDR 13.00 - 13.00 11A0 CC5A/CD5AA030 22,600 TDR 13.00 - 13.00 11.65 CC5A/CD5AW024 22,200 TDR 13.00 - 13.00 11.50 CC5A/CD5AW030 22,600 TDR 13.00 - 13.00 11.65 CE3AA024 22,200 TDR 13.00 - 13.00 11.50 CE3AA030 22,600 TDR 13.00 - 13.00 11.70 CK3BA024 22,200 TDR 13.00 - 13.00 11.75 CK3BA030 22,600 TDR 13.00 - 13.00 11.80 CK5A/CK5BA024 22,200 TDR 13.00 - 13.00 11.60 CK5A/CK5BA030 22,600 TDR 13.00 - 13.00 11.70 CK5A/CK5BW024 22,200 TDR 13.00 - 13.00 11.60 CK5A/CK5BW030 22,600 TDR 13.00 - 13.00 11.75 CK5PA024 22,200 TDR&TXV 13.00 - - 11.55 CK5PA030 22,600 TDR&TXV 13.00 - - 11.65 CK5PW024 22,200 TDR&TXV 13.00 - - 11.60 CK5PW030 22,600 TDR&TXV 13.00 - I - 1 11.70 COILS+315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,200 TDR 13.00 - 13.00 11.50 CC5A/CD5AA030 22,600 TDR 13.00 - 13.00 11.75 CC5A/CD5AW024 22,200 TDR 13.00 - 13.00 11.60 CC5A/CD5AW030 22,600 TDR 13.00 - 13.00 11.75 CE3AA024 22,200 TDR 13.00 - 13.00 11.60 CE3AA030 22,600 TDR 13.00 - 13.00 11.80 CK3BA024 22,200 TDR 13.00 - 13.00 11,85 CK3BA030 22,600 TDR 13.00 - 13.00 11.90 CK5A/CK5BA024 22,200 TDR 13.00 - 13.00 11.70 CK5A/CK5BA030 22,600 TDR 13.00 - 13.00 11.80 CK5A/CK5BW024 22,200 TDR 13.00 - 13.00 11.75 CK5A/CK5BW030 22,600 TDR 13.00 - 13.00 11.85 CK5PA024 22,200 TDR&TXV 13.00 - - 11.70 CK5PA030 22,600 TDR&TXV 13.00 - - 11.80 CK5PW024 22,200 TDR&TXV 13.00 - - 11.70 CK5PW030 22,600 TDR&TXV 13.00 - - 11.85 COILS+315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,200 TDR 13.00 - 13.00 11.50 CC5A/CD5AW030 22,600 TDR 13.00 - 13.00 11.70 CE3AA024 22,200 TDR 13.00 - 13.00 11.50 CE3AA030 22,600 TDR 13.00 - 13.00 11.75 CK3BA024 22,200 TDR 13.00 - 13.00 11.80 024-G CK3BA030 22,600 TDR 13.00 - 13.00 11.85 CK5A/CK5BW024 22,200 TDR 13.00 - 13.00 11.65 CK5A/CK5BW030 22,600 TDR 13.00 - 13.00 11.80 CK5PW024 22,200 TDR&TXV 13.00 - - 11.60 CK5PW030 22,600 TDR&TXV 13.00 - I - 1 11.75 COILS+315(A,J)AV066135 VARIABLE-SPEED FURNACE CE3AA024 22,200 TDR 13.00 - 13.00 11.50 CE3AA030 22,600 TDR 13.00 - 13.00 11.75 COILS+315(A,J)AV066155 VARIABLE-SPEED FURNACE CE3AA024 22,200 TDR 13.00 - 13.00 11.55 CE3AA030 22,600 TDR 13.00 - 13.00 11.80 COILS+355MAV042040 VARIABLE-SPEED FURNACE CE3AA024 22,200 TDR 13.00 - 13.00 11.45 CE3AA030 22,600 TDR 13.00 - 13.00 11.70 COILS+355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,200 TDR 13.00 - 13.00 11.45 CC5A/CD5AA030 22,600 TDR 13.00 - 13.00 11.65 CC5A/CD5AW024 22,200 TDR 13.00 - 13.00 11.50 CC5A/CD5AW030 22,600 TDR 13.00 - 13.00 11.65 CE3AA024 22,200 TDR 13.00 - 13.00 11.55 CE3AA030 22,600 TDR 13.00 - 13.00 11.75 CK3BA024 22,200 TDR 13.00 - 13.00 11.80 CK3BA030 22,600 TDR 13.00 - 13.00 11.85 CK5A/CK5BA024 22,200 TDR 13.00 - 13.00 11.65 CK5A/CK5BA030 22,600 TDR 13.00 - 13.00 11.75 CK5A/CK5BW024 22,200 TDR 13.00 - 13.00 11.65 CK5A/CK5BW030 22,600 TDR 13.00 - 13.00 11.80 CK5PA024 22,200 TDR&TXV 13.00 - - 11.60 CK5PA030 22,600 TDR&TXV 13.00 - - 11.70 CK5PW024 22,200 TDR&TXV 13.00 - - 11.65 CK5PW030 22,600 TDR&TXV 13.00 - I - 1 11.75 COILS+355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,200 TDR 13.00 - 13.00 11.50 CC5A/CD5AW030 22,600 TDR 13.00 - 13.00 11.65 CE3AA024 22,200 TDR 13.00 - 13.00 11.50 CE3AA030 22,600 TDR 13.00 - 13.00 11.70 CK3BA024 22,200 TDR 13.00 - 13.00 11.75 CK3BA030 22,600 TDR 13.00 - 13.00 11.80 . CK5A/CK5BW024 22,200 TDR 13.00 - 13.00 11.60 See notes on page 18. -9- COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt Puron TXV$ EER CK5A/CK5BW030 22,600 TDR 13.00 - 13.00 11.75 CK5PW024 22,200 TDR&TXV 13.00 - - 11.60 CK5PW030 23,200 TDR&TXV 13.00 - - 11.70 COILS+355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,200 TDR 13,00 - 13.00 11.50 CC5A/CD5AW030 22,600 TDR 13.00 - 13.00 11.65 CE3AA024 22,200 TDR 13.00 - 13.00 11.50 CE3AA030 22,600 TDR 13.00 - 13.00 11.75 CK3BA024 22,200 TDR 13.00 - 13.00 11.80 CK3BA030 22,600 TDR. 13.00 - 13.00 11.80 CK5A/CK5BW024 22,200 TDR 13.00 - 13.00 11.65 CK5A/CK5BW030 22,600 TDR. 13.00 - 13.00 11.75 CK5PW024 22,200 TDR&TXV 13.00 - - 11.60 CK5PW030 22,600 TDR&TXV 13.00 - - 11.75 024-G COILS+315(A,J)AV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,200 TDR 13.00 - 13.00 11.50 CC5A/CD5AW030 22,600 TDR. 13.00 - 13.00 11.65 CE3AA024 22,200 TDR 1300 - 13.00 11.55 CE3AA030 22,600 TDR 13.00 - 13.00 11.75 CK3BA024 22,200 TDR. 13.00 - 13.00 11.80 CK3BA030 22,600 TDR 13.00 --- 13.00 11.85 CK5A/CK5BW024 22,200 TDR 13,00 - 13.00 11.65 CK5A/CK5BW030 22,600 TDR 13.00 - 13.00 11.80 CK5PW024 22,200 TDR&TXV 13.00 - - 11.65 CK5PW030 22,600 TDR&TXV 13.00 - - 11.75 COILS+315(A,J)AV060120 VARIABLE-SPEED FURNACE CE3AA024 22,200 TDR 13.00 - 13.00 11.45 CE3AA030 22,600 TDR 13.00 - 13.00 11.70 'CK5A/CK5BA036 29,000 NONE - 12.00 12.00 10.65 CC5A/CD5AA030 28,000 NONE - 11.70 11.70 10.30 CC5A/CD5AA036 29,000 NONE - 12.00 12.00 10.60 CC5A/CD5AW030 28,000 NONE - 11.70 11.70 10.30 CC5A/CD5AW036 29,000 NONE - 12.00 12.00 10.60 CE3AA030 28,000 NONE - 11.70 11.70 10.45 CE3AA036 28,200 NONE 12.00 12.00 10.50 CF5AA036 28,800 NONE - 12.00 12.00 10.55 CK3BA030 28,000 NONE 11.70 11.70 10.35 CK3BA036 29,000 NONE - 12.00 12.00 10.65 CK5A/CK5BA030 28,000 NONE 11.70 11.70 10.35 CK5A/CK5BT036 29,000 NONE 12.00 12.00 10.65 CK5A/CK5BW030 28,000 NONE 11.70 11.70 10.35 CK5A/CK5BW036 29,000 NONE 12.00 12.00 10.65 CK5PA030 28,000 TXV 11.70 - 10.35 CK5PA036 29,000 TXV - 12.00 - 10.65 CK5PT036 29,000 TXV 12.00 - 10.65 CK5PW030 28,000 TXV - 11.70 - 10.35 CK5PW036 29,000 TXV - 12.00 - 10.65 F(A,B)4(A,B)N(F,C)030 28,200 TDR 12.00 - 12.00 10.50 F(A,B 4(A,B)N(F,C)036 28,400 TDR 12.00 - 12.00 10.35 FC4(B,C)NF030 27,800 TDR&TXV 11.70 - 10.45 FC4(B,C)NF036 28,000 TDR&TXV 12.00 - 10.30 FE4ANF002 28,400 TDR&TXV 13.20 - 11.45 FE4ANF003 28,800 TDR&TXV 13.70 - - 11.80 FE4ANF005 29,200 TDR&TXV 14.00 - - 12.15 030-F FF1DNA030 28,400 TDR 12.00 - 12.00 10.45 FG3AAA036 28,200 NONE - 12.00 12.00 10.45 FK4(C,D)NF001 28,000 TDR&TXV 13.00 11.40 FK4(C,D)NF002 28,400 TDR&TXV 13.00 - - 11.45 FK4(C,D)NF003 28,400 TDR&TXV 13.50 - - 11.80 FK4(C,D)NF005 29,200 TDR&TXV 14.00 - - 12.15 FV4(A,B)NF002 28,400 TDR&TXV 13.20 - - 11.45 FV4(A,B)NF003 28,800 TDR&TXV 13.70 - - 11.80 FV4(A,B)NF005 29,200 TDR&TXV 14.00 - - 12.15 FX4(A,B)NF030 27,800 TDR&TXV 12.00 - - 10.60 FX4(A,B)NF036 28,000 TDR&TXV 12.00 - I - 1 10.40 COILS+315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA030 27,800 TDR 12.50 12.50 11.10 CC5A/CD5AA036 28,800 TDR 13.00 - 13.00 11.45 CC5A/CD5AW030 27,800 TDR 12.50 - 12.50 11.10 CE3AA030 28,200 TDR 12.50 12.50 11.20 CE3AA036 28,000 TDR 12.50 12.50 11.30 CK3BA030 27,800 TDR 12.50 12.50 11.15 CK3BA036 28,800 TDR 13.00 - 13.00 11.50 CK5A/CK5BA030 27,800 TDR 12.50 12.50 11.15 CK5A/CK5BA036 28,800 TDR 13.00 13.00 11.50 CK5A/CK5BT036 28,800 TDR 13.00 - 13.00 11.50 CK5A/CK5BW030 27,800 TDR 12.50 12.50 11.15 CK5PA030 28,000 TDR&TXV 12.50 -- 11.10 CK5PA036 28,800 TDR&TXV 13.00 11.50 CK5PT036 28,800 TDR&TXV 13.00 11.50 CK5PW030 28,000 TDR&TXV 12.50 - 11.10 See notes on page 18. _10- COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt PuronTXV$ EER COILS+315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA030 27,800 TDR 12.50 - 12.50 11.25 CC5A/CD5AA036 28,800 TDR 13.00 -- 13.00 11.60 CC5A/CD5AW030 27,800 TDR 12.50 - 12.50 11.25 CC5A/CD5AW036 28,800 TDR 13.00 - 13.00 11.60 CE3AA030 28,200 TDR 12.50 12.50 11.35 CE3AA036 28,600 TDR 13.00 - 13.00 11.50 CK3BA030 27,800 TDR 12.50 - 12.50 11.30 CK3BA036 29,000 TDR 13.00 - 13.00 11.65 CK5A/CK5BA030 27,800 TDR 12.50 - 12.50 11.30 CK5A/CK5BA036 29,000 TDR 13.00 - 13.00 11.65 CK5A/CK5BW030 27,800 TDR 12.50 - 12.50 11.30 CK5A/CK5BW036 29,000 TDR 13.00 - 13.00 11.65 CK5PA030 28,200 TDR&TXV 12.50 - - 11.25 CK5PA036 29,000 TDR&TXV 13.00 - - 11.65 CK5PT036 29,000 TDR&TXV 13.00 - - 11.65 CK5PW030 28,200 TDR&TXV 12.50 - - 11.25 CK5PW036 29,000 TDR&TXV 13.00 - I - 1 11.65 COILS+315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 28,600 TDR 13.00 - 13.00 11.50 CC5A/CD5AW030 27,600 TDR 12.50 - 12.50 11.20 CC5A/CD5AW036 28,600 TDR 13.00 - 13.00 11.55 CE3AA030 27,800 TDR 12.50 - 12.50 11.25 CE3AA036 28,000 TDR 13.00 - 13.00 11.40 CK3BA030 27,800 TDR 12.50 - 12.50 11.35 CK3BA036 28,800 TDR. 13.00 - 13.00 11.55 CK5A/CK5BA036 28,800 TDR 13.00 - 13.00 11.55 CK5A/CK5BT036 28,800 TDR 13.00 - 13.00 11.55 CK5A/CK5BW030 27,800 TDR 12.50 - 12.50 11.30 CK5A/CK5BW036 28,800 TDR 13.00 - 13.00 11.60 CK5PA036 28,800 TDR&TXV 13.00 - - 11.55 CK5PT036 28,800 TDR&TXV 13.00 - - 11.55 CK5PW030 28,200 TDR&TXV 12.50 - - 11.25 CK5PW036 28,800 TDR&TXV 13.00 - I - 1 11.60 COILS+315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AW036 28,600 TDR 13.00 - 13.00 11.60 CE3AA030 27,800 TDR 12.50 - 12.50 11.30 CE3AA036 28,200 TDR 13.00 - 13.00 11.45 CK5A/CK5BW036 28,800 TDR 13.00 - 13.00 11.65 CK5PW036 28,800 TDR&TXV 13.00 - - 11.65 030-F COILS+315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AW036 28,200 TDR 13.00 - 13.00 11.65 CE3AA030 27,800 TDR 12.50 - 12.50 11.35 CE3AA036 28,200 TDR 13.00 - 13.00 11.50 CK5A/CK5BW036 28,800 TDR 13.00 - 13.00 11.70 CK5PW036 28,800 TDR&TXV 13.00 - - 11.65 COILS+355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 - 1250 10.80 CC5A/CD5AW036 29,000 TDR 13.00 - 13.00 1130 CK5A/CK5BW030 28,000 TDR 12.50 - 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 - 13.00 11.60 CK5PW030 28,000 TDR&TXV 12.50 11.20 CK5PW036 29,000 TDR&TXV 13.00 - - 11.60 COILS+355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,000 TDR 13.00 - 13.00 11.25 CC5A/CD5AW030 28,000 TDR 12.50 - 12.50 10.80 CK3BA030 28,000 TDR 12.50 - 12.50 10.85 CK3BA036 29,000 TDR. 13.00 - 13.00 11.30 CK5A/CK5BA036 29,000 TDR 13.00 - 13.00 11.30 CK5A/CK5BW030 28,000 TDR 12.50 - 12.50 11.20 CK5PA036 29,000 TDR&TXV 13.00 - - 11.30 CK5PW030 28,000 TDR&TXV 12.50 - - 11.20 COILS+355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 - 12.50 10.75 CC5A/CD5AW.036 29,000 TDR 13.00 - 13.00 11.40 CK5A/CK5BW030 28,000 TDR 12.50 - 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 - 13.00 11.60 CK5PW030 28,000 TDR&TXV 12.50 - - 11.20 CK5PW036 29,000 TDR&TXV 13.00 - - 11.60 COILS+355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 - 12.50 10.75 CC5A/CD5AW036 29,000 TDR 13.00 - 13.00 11.25 CK5A/CK5BW030 28,000 TDR 12.50 - 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 - 13.00 11.60 CK5PW030 28,000 TDR&TXV 12.50 - - 11.20 CK5PW036 29,000 TDR&TXV 13.00 - - 11.60 COILS+355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 - 12.50 11.15 See notes on page 18. -11- COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt PuronTXV$ EER CC5A/CD5AW036 29,000 TDR 1350 - 13.50 11.60 CK5A/CK5BW030 28,000 TDR 12 50 - 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 - 13.00 11.60 CK5PW030 28,000 TDR&TXV 12.50 - - 11.20 030-F CK5PW036 29,000 TDR&TXV 13.00 - I - 1 11.60 COILS+355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,000 TDR 13.00 - 13.00 11.55 CK5A/CK5BW036 29,000 TDR 13.00 - 13.00 11.60 CK5PW036 29,000 TDR&TXV 13.00 - - 11.60 'CK5A/CK5BA042 35,000 NONE - 12.00 12.00 10.55 CC5A/CD5AA036 35,000 NONE - 12.00 12.00 10.55 CC5A/CD5AA042 35,000 NONE - 12.00 12.00 10.55 CC5A/CD5AW036 35,000 NONE - 12.00 12.00 10.55 CC5A/CD5AW042 34,800 NONE - 12.00 12.00 10.45 CE3AA036 34,600 NONE - 11.70 11.70 10.45 CE3AA042 35,000 NONE - 12.00 12.00 10.60 CF5AA036 34,800 NONE - 12.00 12.00 10.50 CK3BA036 35,000 NONE - 12.00 12.00 10.55 CK3BA042 35,000 NONE - 12.00 12.00 %55 CK5A/CK5BA036 35,000 NONE - 12.00 12.00 10.55 CK5A/CK5BT036 35,000 NONE - 12.00 12.00 10.55 CK5A/CK5BT042 35,000 NONE - 12.00 12.00 10.55 CK5A/CK5BW036 35,000 NONE - 12.00 12.00 10.55 CK5PA036 35,000 TXV - 12.00 - 10.55 CK5PA042 35,000 TXV - 12.00 - 10.55 CK5PT036 35,000 TXV - 12.00 - 10.55 CK5PT042 35,000 TXV - 12.00 - 10.55 CK5PW036 35,000 TXV - 12.00 - 10.55 F(A,B)4(A,B)N(F,B,C)042 35,000 TDR 12.00 - 12.00 10.50 F(A,B)4(A,B)N(F,C)036 34,000 TDR 11.50 - 11.50 10.25 FC4(B,C)N(F,B)042 34,000 TDR&TXV 12.00 - - 10.45 FC4(B,C)NB054 35,000 TDR&TXV 12.50 - - 11.10 FC4(B,C)NF036 33,600 TDR&TXV 11.50 - - 10.15 FE4ANB006 35,800 TDR&TXV 14.00 - - 12.25 FE4ANF002 34,000 TDR&TXV 12.60 - - 11.00 FE4ANF003 34,200 TDR&TXV 13.00 - - 11.50 FE4ANF005 35,000 TDR&TXV 13.70 - - 11.95 FG3AAA036 34,000 NONE - 11.50 11.50 10.35 FK4 C,D NB006 35,400 TDR&TXV 14.00 - - 12.25 FK4 C.D NF001 33,800 TDR&TXV 12.50 - - 10.95 FK4(C,D NF002 34,000 TDR&TXV 12.50 - - 11.05 FK4 C,D NF003 34,200 TDR&TXV 13.00 - - 11.50 FK4 C,D NF005 35,000 TDR&TXV 13.50 - - 11.95 FV4 A.B)NI3006 35,800 TDR&TXV 14.00 - - 12.25 FV4 A,B NF002 34.000 TDR&TXV 12.60 - - 11.00 FV4 A,B NF003 34,200 TDR&TXV 13.00 - - 11.50 036-G FV4 A,B NF005 35,000 TDR&TXV 13.70 -- - 11.95 FX4 A,B NF036 34,000 TDR&TXV 11.60 - - 10.30 FX4 A,B NF042 34,000 TDR&TXV 12.10 - - 10.60 COILS+315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.50 - 12.50 11.10 CE3AA036 34,200 TDR 12.50 - 12.50 11.00 CE3AA042 34,600 TDR 12.50 - 12.50 11.25 CK3BA036 34,600 TDR 12.50 - 12.50 11.15 CK5A/CK5BA036 34,600 TDR 12.50 - 12.50 11.15 CK5A/CK5BE042 34,600 TDR 12.50 - 12.50 11.30 CK5A/CK5BT036 34,600 TDR 12.50 - 12.50 11.15 CK5PA036 34,600 TDR&TXV 12.50 - - 11.15 CK5PE042 34,600 TDR&TXV 12.50 - - 11.25 CK5PT036 34.600 TDR&TXV 12.50 - - 11.15 COILS+315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.50 - 12.50 11.30 CC5A/CD5AA042 34,600 TDR 13.00 - 13.00 11.40 CC5A/CD5AW036 34,600 TDR 12.50 - 12.50 11.30 CE3AA036 34,200 TDR 12.50 - 12.50 11.20 CE3AA042 34,600 TDR 13.00 - 13.00 11.40 CK3BA036 34,600 TDR 12,50 - 12.50 11.35 CK3BA042 34,600 TDR 13.00 - 13.00 11.40 CK5A/CK5BA036 34,600 TDR 12.50 - 12.50 11.35 CK5A/CK5BA042 34,600 TDR 13.00 - 13.00 11.40 CK5A/CK5BE042 34,600 TDR 13.00 - 13.00 11.45 CK5A/CK5BT036 34,600 TDR 12.50 - 12.50 11.35 CK5A/CK5BT042 34,600 TDR 13.00 - 13.00 11.40 CK5A/CK5BW036 34,600 TDR 12.50 - 12.50 11.35 CK5PA036 34,600 TDR&TXV 12.50 - - 11.30 CK5PA042 34,600 TDR&TXV 13.00 - - 11.35 CK5PE042 34,600 TDR&TXV 13.00 - - 11.45 CK5PT036 34,600 TDR&TXV 12.50 - - 11.30 CK5PT042 34,600 TDR&TXV 13.00 - - 11.35 CK5PW036 34,600 TDR&TXV 12.50 - I - 1 11.30 COILS+315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,400 TDR 13.00 - 13.00 11.25 See notes on page 18. -12- i� ., � COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt PuronTXV$ EER CC5A/CD5AA042 34,400 TDR 13.00 - 13.00 11-35 CC5A/CD5AW036 34,400 TDR 13.00 - 13.00 11.30 CC5A/CD5AW042 34,000 TDR 13.00 - 13.00 11.25 CE3AA036 34,000 TDR 12.50 - 12.50 11.15 CE3AA042 34,600 TDR 13.00 - 13.00 11.40 CK3BA036 34,600 TDR 13.00 - 13.00 11.30 CK3BA042 34,600 TDR 13.00 - 13.00 11.35 CK5A/CK5BA036 34,600 TDR 13.00 - 13.00 11.30 CK5A/CK5BA042 34,600 TDR 13.00 - 13.00 11.35 CK5A/CK5BE042 34,600 TDR 13.00 - 13.00 11.40 CK5A/CK5BT036 34,600 TDR 13.00 - 13.00 11.30 CK5A/CK5BT042 34,600 TDR 13.00 - 13.00 11.35 CK5A/CK5BW036 34,600 TDR 13.00 - 13.00 11.35 CK5PA036 34,600 TDR&TXV 13.00 - - 11.25 CK5PA042 34,600 TDR&TXV 13.00 - - 11.30 CK5PE042 34,600 TDR&TXV 13.00 - - 11.40 CK5PT036 34,600 TDR&TXV 13.00 - - 11.25 CK5PT042 34,600 TDR&TXV 13.00 - - 11.30 CK5PW036 34.600 TDR&TXV 13.00 - I - 11.30 COILS+315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.00 - 13.00 11.45 CC5A/CD5AW036 34,600 TDR 13.00 - 13.00 11.30 CC5A/CD5AW042 34,400 TDR 13.00 - 13.00 11.40 CE3AA036 34,200 TDR 12.50 - 12.50 11.20 CE3AA042 34,600 TDR 13.00 - 13.00 11.45 CK3BA042 34,600 TDR 13.00 - 13.00 11.45 CK5A/CK5BA042 34,600 TDR 13.00 - 13.00 11.45 CK5A/CK5BT042 34,600 TDR 13.00 - 13.00 11.45 CK5A/CK5BW036 34,600 TDR 13.00 - 13.00 11.35 CK5PA042 34,600 TDR&TXV 13.00 - - 11.40 CK5PT042 34,600 TDR&TXV 13.00 - - 11.40 CK5PW036 34,600 TDR&TXV 13.00 - - 11.35 COILS+315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.00 - 13.00 11.55 CC5A/CD5AW036 34,600 TDR 13.00 - 13.00 11.35 CC5A/CD5AW042 34,400 TDR 13.00 - 13.00 11.50 CE3AA036 34,200 TDR 12.50 - 12.50 11.25 CE3AA042 34,600 TDR 13.00 - 13.00 11,55 CK3BA042 34,600 TDR 13.00 13.00 11.55 CK5A/CK5BA042 34,600 TDR 13.00 - 13.00 11.55 036-G CK5A/CK5BT042 34,600 TDR 13.00 13.00 11.55 CK5A/CK5BW036 34,600 TDR 13.00 13-00 11.40 CK5PA042 34,600 TDR&TXV 13.00 - 11.50 CK5PT042 34,600 TDR&TXV 13.00 - - 11.50 CK5PW036 34,600 TDR&TXV 13.00 - - 11.40 COILS+355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 - 12.50 11.20 CC5A/CD5AW036 34,600 TDR 12.50 - 12.50 11.10 CK5A/CK5BA042 34,600 TDR 12.50 - 12.50 11.25 CK5A/CK5BW036 34,600 TDR 12.50 - 12.50 11.15 CK5PA042 34,600 TDR&TXV 12.50 - - 11.25 CK5PW036 34,600 TDR&TXV 12.50 - - 11.15 COILS+355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.50 - 12.50 11.10 CK3BA036 34,600 TDR 12.50 - 12.50 11.15 CK3BA042 34,600 TDR 12.50 - 12.50 11.20 CK5A/CK5BA036 34,600 TDR 12.50 - 12.50 11.15 CK5PA036 34,600 TDR&TXV 12.50 - - 11.15 COILS+355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 - 12.50 11.25 CC5A/CD5AW036 34,600 TDR 12.50 - 12.50 11.20 CK3BA042 34,600 TDR 12.50 - 12.50 11.25 CK5A/CK5BA042 34,600 TDR 12.50 12.50 11.30 CK5A/CK5BW036 34,600 TDR 12.50 - 12.50 11.25 CK5PA042 34,600 TDR&TXV 12.50 - - 11.30 CK5PW036 34,600 TDR&TXV 12.50 - - 11.25 COILS+355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 - 12.50 11.15 CC5A/CD5AW036 34,600 TDR 12.50 - 12.50 11.10 CK3BA042 34,600 TDR 12.50 - 12.50 11.20 CK5A/CK5BA042 34,600 TDR 12.50 - 12.50 11.20 CK5A/CK5BW036 34,600 TDR 12.50 - 12.50 11.15 CK5PA042 34,600 TDR&TXV 12.50 - - 11.20 CK5PW036 34,600 TDR&TXV 12.50 - - 11.15 COILS+355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.00 - 13.00 11A0 CC5A/CD5AW036 34,600 TDR 13.00 - 13.00 11.40 CK3BA042 34,600 TDR 13.00 - 13.00 11.40 CK5A/CK5BA042 34,600 TDR 13.00 - 13.00 11.45 See notes on page 18. -13- COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt PuronTXV$ EER CK5A/CK5BW036 34,600 TDR 13.00 - 13.00 11.40 CK5PA042 34,600 TDR&TXV 13.00 - - 11.45 CK5PW036 34,600 TDR&TXV 13.00 - - 11.40 COILS+355MAV060120 VARIABLE-SPEED FURNACE 036-G CC5A/CD5AA042 34,600 TDR 13.00 - 13.00 11.40 CC5A/CD5AW036 34,600 TDR 13.00 - 13.00 11.35 CK5A/CK5BA042 34,600 TDR 13.00 - 13.00 11.45 CK5A/CK5BW036 34,600 TDR 13.00 - 13.00 11.35 CK5PA042 34,600 TDR&TXV 13.00 - - 11.45 CK5PW036 34,600 TDR&TXV 13.00 - - 11.35 "CK5A/CK5BA048 40,000 NONE - 12.00 12.00 10.25 CC5A/CD5AC048 39,500 NONE - 11.70 11.70 10.10 CC5A/CD5AW042 39,500 NONE - 11.70 11.70 10.10 CC5A/CD5AW048 40,000 NONE - 12.00 12.00 10.20 CD5AA048 40,000 NONE - 12.00 12.00 10.25 CE3AA042 39,500 NONE - 12.00 12.00 10.25 CE3AA048 40,000 NONE - 12.00 12.00 10.30 CF5AA048 39,500 NONE - 12.00 12.00 10.25 CK3BA042 39,500 NONE - 11.70 11.70 10.20 CK3BA048 40,000 NONE - 12.00 12.00 10.25 CK5A/CK5BA042 39,500 NONE - 11.70 11.70 10.20 CK5A/CK5BT042 39,500 NONE - 11.70 11.70 10.20 CK5A/CK5BT048 40,000 NONE - 12.00 12.00 10.25 CK5A/CK5BW048 40,000 NONE - 12.00 12.00 10.25 CK5PA042 39,500 TXV - 11.70 - 10.20 CK5PA048 40,000 TXV -- 12.00 - 10.25 CK5PT042 39,500 TXV - 11.70 - 10.20 CK5PT048 40,000 TXV - 12.00 - 10.25 CK5PW048 40,000 TXV - 12.00 - 10.25 F(A,B)4(A,B)N(F,B,C)042 39,500 TDR 11.70 - 11.70 10.05 F(A,B)4(A,B)N(F,B,C)048 40,000 TDR 12.00 - 12.00 10.25 FC4(B,C N(F,B)042 38,500 TDR&TXV 11.50 - - 9.90 FC4(B,C N(FB)048 39,500 TDR&TXV 11.70 - - 10.05 FC4(B,C)NB054 40,500 TDR&TXV 12.20 - - 10.65 FE4ANB006 40,500 TDR&TXV 13.70 - - 11.60 FE4ANF003 38,500 TDR&TXV 12.70 - - 10.85 FE4ANF005 40,500 TDR&TXV 13.20 - - 11.30 FG3AAA048 40,000 NONE - 11.70 11.70 10.20 FK4(C,D)NB006 40,500 TDR&TXV 13.50 - - 11.60 FK4(C,D)NF003 38,500 TDR&TXV 12.50 - - 10.85 FK4(C,D)NF005 40,000 TDR&TXV 13.00 - - 11.30 FV4(A,B)NB006 40,500 TDR&TXV 13.70 - - 11.60 FV4(A,B)NF003 38,500 TDR&TXV 12.70 - - 10.85 FV4(A,B)NF005 40,500 TDR&TXV 13.20 - - 11.30 FX4(A,B)NF042 38,500 TDR&TXV 11.70 - - 10.05 FX4(A,B)NF048 39.500 TDR&TXV 12.00 - I - 1 10.20 042-F COILS+315(A,J)AV046090 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 - 12.50 10.85 CC5A/CD5AC048 39,000 TDR 12.50 - 12.50 10.85 CD5AA048 39,500 TDR 12.50 - 12.50 11.00 CE3AA042 39,000 TDR 12.20 - 12.20 10.90 CE3AA048 39,500 TDR 12.50 - 12.50 10.95 CK3BA042 39,000 TDR 12.50 - 12.50 10.85 CK3BA048 39,500 TDR 12.50 - 12.50 10.95 CK5A/CK5BA042 39,000 TDR 12.50 - 12.50 10.85 CK5A/CK5BA048 39,500 TDR 12.50 - 12.50 10.95 CK5A/CK5BE042 39,500 TDR 12.50 - 12.50 10.90 CK5A/CK5BT042 39,000 TDR 12.50 - 12.50 10.85 CK5A/CK5BT048 39,500 TDR 12.50 - 12.50 10.95 CK5PA042 39,000 TDR&TXV 12.50 - - 10.85 CK5PA048 39,500 TDR&TXV 12.50 - - 10.95 CK5PE042 39,500 TDR&TXV 12.50 - - 10.90 CK5PT042 39,000 TDR&TXV 12.50 - - 10.85 CK5PT048 39,500 TDR&TXV 12.50 - I - 1 10.95 COILS+315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 - 12.50 10.80 CC5A/CD5AC048 39,000 TDR 12.50 - 12.50 10.70 CC5A/CD5AW042 38,500 TDR 12.50 - 12.50 10.75 CC5A/CD5AW048 39,500 TDR 12.50 - 12.50 10.90 CD5AA048 39,500 TDR 12.50 - 12.50 10.90 CE3AA042 39,000 TDR 12.50 - 12.50 10.85 CE3AA048 39,500 TDR 12.50 - 12.50 10.90 CK3BA042 39,000 TDR 12.50 - 12.50 10.80 CK3BA048 39,500 TDR 12.50 - 12.50 10.95 CK5A/CK5BA042 39,000 TDR 12.50 - 12.50 10.75 CK5A/CK5BA048 39,500 TDR. 12.50 - 12.50 10.95 CK5A/CK5BE042 39,000 TDR 12.50 - 12.50 10.80 CK5A/CK5BT042 39,000 TDR 12.50 - 12.50 10.75 CK5A/CK5BT048 39,500 TDR 12.50 - 12.50 10.95 CK5A/CK5BW048 39,500 TDR 13.00 - 13.00 11.05 CK5PA042 39,000 TDR&TXV 12.50 - - 10.80 CK5PA048 39,500 TDR&TXV 12.50 - - 10.95 See notes on page 18. -14- • S� , 1 � - , l� COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt Puron TXV$ EER CK5PE042 39,000 TDR&TXV 12.50 - - 10.80 CK5PT042 39,000 TDR&TXV 12.50 - - 10.80 CK5PT048 39,500 TDR&TXV 12.50 - - 10.95 CK5PW048 39,500 TDR&TXV 13.00 - - 11.05 COILS+315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR. 12.50 - 12.50 10.95 CC5A/CD5AC048 39,000 TDR 12.50 - 12.50 11.00 CC5A/CD5AW042 39,000 TDR. 12.50 12.50 10.85 CC5A/CD5AW048 39,500 TDR 13.00 13.00 11.10 CD5AA048 39,500 TDR 12.50 - 12.50 11.10 CE3AA042 39,000 TDR 12.50 12.50 11.00 CE3AA048 39,500 TDR 12.50 12.50 11.05 CK3BA042 39,000 TDR 12.50 12.50 10.95 CK3BA048 39,500 TDR 12.50 - 12.50 11.10 CK5A/CK5BA042 39,000 TDR 12.50 12.50 10.95 CK5A/CK5BA048 39,500 TDR 12.50 - 12.50 11.10 CK5A/CK5BT042 39,000 TDR 12.50 - 12.50 10.95 CK5A/CK5BT048 39,500 TDR 12.50 12.50 11.10 CK5A/CK5BW048 39,500 TDR 13.00 13.00 11.10 CK5PA042 39,000 TDR&TXV 12.50 - - 11.00 CK5PA048 39,500 TDR&TXV 12.50 - 11.10 CK5PT042 39,000 TDR&TXV 12.50 - - 11.00 CK5PT048 39,500 TDR&TXV 12.50 - - 11.10 CK5PW048 39,500 TDR&TXV 13.00 - 11.10 COILS+315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 - 12.50 11.00 CC5A/CD5AC048 39,000 TDR 12.50 - 12.50 11.05 CC5A/CD5AW042 39,000 TDR 12.50 - 12.50 10.90 CC5A/CD5AW048 39,500 TDR 13.00 - 13.00 11.15 CD5AA048 39,500 TDR 12.50 - 12.50 11.15 CE3AA042 39,000 TDR 12.50 - 12.50 11.05 CE3AA048 39,500 TDR 12.50 - 12.50 11.10 CK3BA042 39,000 TDR 12.50 - 12.50 11.00 CK3BA048 39,500 TDR 12.50 - 12.50 11.15 CK5A/CK5BA042 39,000 TDR 12.50 12.50 11.00 CK5A/CK5BA048 39,500 TDR 12.50 - 12,50 11.15 CK5A/CK5BT042 39,000 TDR 12.50 12.50 11.00 CK5A/CK5BT048 39,500 TDR 12.50 12.50 11.15 CK5A/CK5BW048 39,500 TDR 13.00 - 13.00 11.15 CK5PA042 39,000 TDR&TXV 12.50 - - 11.00 042-F CK5PA048 39,500 TDR&TXV 12.50 - 11.15 CK5PT042 39,000 TDR&TXV 12.50 - - 11.00 CK5PT048 39,500 TDR&TXV 12.50 - 11.15 CK5PW048 39,500 TDR&TXV 13.00 - 11A5 COILS+355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.20 12.20 10.60 CC5A/CD5AW048 39,500 TDR 12.50 12.50 10.65 CK5A/CK5BA042 39,000 TDR 12.20 12.20 10.60 CK5A/CK56W048 39,500 TDR 12.50 - 12.50 10.75 CK5PA042 39,000 TDR&TXV 12.20 - - 10.60 CK5PW048 39,500 TDR&TXV 12.50 - - 10.75 COILS+355MAV042060 VARIABLE-SPEED FURNACE CK3BA042 39,000 TDR. 12.50 - 12.50 10.60 CK5A/CK5BE042 39,500 TDR. 12.45 - 12.45 10.55 CK5PE042 39,500 TDR&TXV 12.45 - - 10.55 COILS+355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 12.50 10.70 CC5A/CD5AC048 39,000 TDR. 12.50 - 12.50 10.65 CD5AA048 39,500 TDR 12.50 - 12.50 10.80 CK3BA042 39,000 TDR 12.50 12.50 10.75 CK3BA048 39,500 TDR 12.50 12.50 10.85 CK5A/CK5BA042 39,000 TDR 12.50 12.50 10.75 CK5A/CK5BA048 39,500 TDR 12.50 - 12.50 10.85 CK5PA042 39,000 TDR&TXV 12.50 - - 10.75 CK5PA048 39,500 TDR&TXV 12.50 - - 10.85 COILS+355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.20 12.20 10.60 CC5A/CD5AC048 39,000 TDR 12.20 12.20 10.50 CD5AA048 39,500 TDR 12.50 - 12.50 10.65 CK3BA042 39,000 TDR 12.20 12.20 10.60 CK3BA048 39,500 TDR. 12.50 - 12.50 10.75 CK5A/CK5BA042 39,000 TDR 12.20 - 12.20 10.60 CK5A/CK5BA048 39,500 TDR 12.50 - 12.50 10.75 CK5PA042 39,000 TDR&TXV 12.20 - 10.60 CK5PA048 39,500 TDR&TXV 12.50 - 10.75 COILS+355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 - 12.50 10.90 CC5A/CD5AC048 39,000 TDR 12.50 - 12.50 10.80 CD5AA048 39,500 TDR 12.50 - 12.50 10.95 See notes on page 18. -15- COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt Puron TXVt EER CK38AO42 39,000 TDR. 12.50 - 12.50 10.90 CK3BA048 39,500 TDR 12.50 - 12.50 11.05 CK5A/CK5BA042 39,000 TDR. 12.50 - 12.50 10.90 CK5A/CK5BA048 39,500 TDR. 13.00 - 13.00 11.05 CK5PA042 39,000 TDR&TXV 12.50 - - 10.90 CK5PA048 39,500 TDR&TXV 13.00 - I - 1 11.05 042-F COILS+355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 - 12.50 10.90 CC5A/CD5AW048 39,500 TDR 12.50 - 12.50 11.00 CK5A/CK5BA042 39,000 TDR. 12.50 - 12.50 10.90 CK5A/CK5BW048 39,500 TDR. 12.50 - 12.50 11.00 CK5PA042 39,000 TDR&TXV 12.50 - - 10.90 CK5PW048 39,500 TDR&TXV 12.50 - - 11.00 'CK5A/CK5BA060 46,000 NONE - 12.00 12.00 10.40 CC5A/CD5AA060 45,000 NONE - 11.70 11.70 10.15 CC5A/CD5AC048 44,000 NONE - 11.70 11.70 10.05 CC5A/CD5AW048 45,000 NONE - 11.70 11.70 10.15 CC5A/CD5AW060 46,500 NONE - 12.00 12.00 10.35 CD5AA048 45,000 NONE - 11.70 11.70 10.15 CE3AA048 45,000 NONE - 11.70 11.70 10.25 CE3AA060 46,000 NONE - 12.00 12.00 10.40 CF5AA048 44,000 NONE - 11.70 11.70 10.20 CK36AO48 45,000 NONE - 11.70 11.70 10.20 CK3BA060 46,000 NONE - 12.00 12.00 10.40 CK5A/CK5BA048 45,000 NONE - 11.70 11.70 10.20 CK5A/CK5BT048 45,000 NONE - 11.70 11.70 10.20 CK5A/CK5BT060 46,000 NONE - 12.00 12.00 10.40 CK5A/CK5BW048 45,000 NONE - 11.70 11.70 10.20 CK5A/CK5BX060 46,500 NONE - 12.00 12.00 10.50 CK5PA048 45,000 TXV - 11.70 - 10.20 CK5PA060 46,000 TXV - 12,00 - 10.40 CK5PT048 45,000 TXV - 11.70 - 10.20 CK5PT060 46,000 TXV - 12.00 - 10.40 CK5PW048 45,000 TXV - 11.70 - 10.20 CK5PX060 46,500 TXV - 12.00 - 10.50 F(A,B)4(A,B)N(F,B,C)048 45,000 TDR 11.70 - 11.70 10.10 F(A,B)4(A,B)N(F,B,C)060 46,000 TDR 11.70 - 11.70 10.10 FB4(A,B)NB070 46,500 TDR 12.00 - 12.00 10.45 FC4(B,C)N(F,B)048 44,500 TDR&TXV 11.50 - - 10.00 FC4(B,C)N(F,8)060 45,000 TDR&TXV 11.50 - - 9.95 FC4(B,C) 8054 45,000 TDR&TXV 12.00 - - 10.35 FC4(B,C)NB070 46,000 TDR&TXV 12.00 - - 10.30 FE4ANB006 46,000 TDR&TXV 13.20 - - 11.35 FE4ANF005 45,000 TDR&TXV 12.70 - - 11.00 FG3AAA048 44,000 NONE - 11.50 11.50 10.15 FG3AAA060 45,000 NONE - 11.70 11.70 10.30 FK4(C,D)NB006 46,000 TDR&TXV 13.00 - - 11.35 048-F FK4(C,D)NF005 45,000 TDR&TXV 12.50 - - 11.05 FV4(A,B)NB006 46,000 TDR&TXV 13.20 - - 11.35 FV4(A,B)NF005 45,000 TDR&TXV 12.70 - - 11.00 FX4(A,B)NB060 45,500 TDR&TXV 12.00 - - 10.30 FX4(A,B)NF048 45,000 TDR&TXV 11.70 - - 10.15 COILS+315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AC048 43,500 TDR 12.00 - 12.00 10.50 CD5AA048 44,500 TDR 12.00 - 12.00 10.60 CE3AA048 44,500 TDR 12.00 - 12.00 10.60 CE3AA060 45,000 TDR 12.50 - 12.50 10.90 CK3BA048 44,500 TDR 12.00 - 12.00 10.60 CK5A/CK5BA048 44,500 TDR 12.00 - 12.00 10.60 CK5A/CK5BT048 44,500 TDR 12.00 - 12.00 10.60 CK5PA048 44,500 TDR&TXV 12.00 - - 10.60 CK5PT048 44,500 TDR&TXV 12.00 - - 10.60 COILS+315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.00 - 12.00 10.60 CC5A/CD5AC048 43,500 TDR 12.00 - 12.00 10.40 CC5A/CD5AW048 44,500 TDR 12.00 - 12.00 10.60 CD5AA048 44,500 TDR 12.00 - 12.00 10.55 CD5PX060 45,500 TDR&TXV 12.50 - - 11.00 CE3AA048 44,500 TDR 12.00 - 12.00 10.60 CE3AA060 45,000 TDR 12.50 - 12.50 10.95 CK3BA048 44,500 TDR 12.00 - 12.00 10.65 CK3BA060 45,000 TDR 12.50 - 12.50 10.95 CK5A/CK5BA048 44,500 TDR 12.00 - 12.00 10.60 CK5A/CK5BA060 45,000 TDR 12.50 - 12.50 10.95 CK5A/CK5BT048 44,500 TDR 12.00 - 12.00 10.60 CK5A/CK5BT060 45,000 TDR. 12.50 - 12.50 10.95 CK5A/CK5BW048 44,500 TDR 12.00 - 12.00 10.70 CK5A/CK5BX060 45,500 TDR 13.00 - 13.00 11.05 CK5PA048 44,500 TDR&TXV 12.00 - - 10.60 CK5PA060 45,000 TDR&TXV 12.50 - - 10.95 CK5PT048 44,500 TDR&TXV 12.00 - - 10.60 CK5PT060 45,000 TDR&TXV 12.50 - - 10.95 See notes on page 18. -16- COMBINATION RATINGS Continuea SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt PuronTXV$ EER CK5PW048 44,500 TDR&TXV 12.50 - - 10.70 CK5PX060 45,500 TDR&TXV 12.50 1 - I - 1 11.05 COILS+315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA060 44,500 TDR. 12.50 12.50 10.80 CC5A/CD5AC048 44,000 TDR 12.00 - 12.00 10.65 CC5A/CD5AW048 44,500 TDR 12.50 12.50 10.75 CC5A/CD5AW060 45,500 TDR 12.50 - 12.50 11.05 CD5AA048 44,500 TDR 12.00 - 12.00 10.80 CE3AA048 44,500 TDR 12.00 - 12.00 10.75 CE3AA060 45,000 TDR 12.50 - 12.50 11.05 CK3BA048 44,500 TDR 12.00 - 12.00 10.75 CK3BA060 45,000 TDR 12.50 - 12.50 11.05 CK5A/CK5BA048 44,500 TDR 12.00 - 12.00 10.75 CK5A/CK5BA060 45,000 TDR 12.50 - 12.50 11.05 CK5A/CK5BT048 44,500 TDR 12.00 - 12.00 10.75 CK5A/CK5BT060 45,000 TDR 12.50 - 12.50 11.05 CK5A/CK5BW048 44,500 TDR 12.00 - 12.00 10.75 CK5A/CK5BX060 45,500 TDR 12.50 - 12.50 11.25 CK5PA048 44,500 TDR&TXV 12.00 - - 10.80 CK5PA060 45,000 TDR&TXV 12.50 - 11.05 CK5PT048 44,500 TDR&TXV 12.00 - - 10.80 CK5PT060 45,000 TDR&TXV 12.50 - - 11.05 CK5PW048 44,500 TDR&TXV 12.00 - - 10.80 CK5PX060 45,500 TDR&TXV 12.50 - - 11.25 COILS+315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,000 TDR 12.50 - 12.50 10.90 CC5A/CD5AC048 44,000 TDR 12.50 - 12.50 10.75 CC5A/CD5AW048 44,500 TDR 12.50 - 12.50 10.90 CC5A/CD5AW060 45,500 TDR 13.00 - 13.00 11.15 CD5AA048 44,500 TDR 12.50 - 12.50 10.90 CE3AA048 44,500 TDR 12.00 - 12.00 10.85 CE3AA060 45,000 TDR 12.50 - 12.50 11.15 CK3BA048 44,500 TDR 12.00 12.00 10.85 CK3BA060 45,000 TDR 12.50 12.50 11.15 CK5A/CK5BA048 44,500 TDR 12.00 12.00 10.85 CK5A/CK5BA060 45,000 TDR 12.50 - 12.50 11.15 CK5A/CK5BT048 44,500 TDR 12.00 12.00 10.85 CK5A/CK5BT060 45,000 TDR 12.50 - 12.50 11.15 CK5A/CK5BW048 44,500 TDR 12.00 - 12.00 10.85 048-F CK5A/CK5BX060 45,500 TDR 13.00 13_00 11.30 CK5PA048 44,500 TDR&TXV 12.00 - 10.85 CK5PA060 45,000 TDR&TXV 12.50 - 11.15 CK5PT048 44,500 TDR&TXV 12.00 - - 10.85 CK5PT060 45,000 TDR&TXV 12.50 - 11.15 CK5PW048 44,500 TDR&TXV 12.00 - - 10.85 CK5PX060 45,500 TDR&TXV 13.00 - - 11.30 COILS+355MAV042080 VARIABLE-SPEED FURNACE CD5AA048 44,500 TDR 12.00 - 12.00 10.40 CK3BA048 44,500 TDR 12.00 - 12.00 10.40 CK5A/CK5BA048 44,500 TDR 12.00 - 12.00 10.40 CK5PA048 44,500 TDR&TXV 12.00 - - 10.40 COILS+355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW060 45,500 TDR. 12.00 - 12.00 10.55 CK3BA048 44,500 TDR 12.00 - 12.00 10.30 CK3BA060 45,000 TDR 12.00 - 12.00 10.50 CK5A/CK5BA060 45,000 TDR - 12.00 - 12.00 10.50 CK5A/CK5BX060 46,000 TDR 12.00 - 12.00 10.70 CK5PA060 45,000 TDR&TXV 12.00 - - 10.50 CK5PX060 46,000 TDR&TXV 12.00 - - 10.70 COILS+355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.00 - 12.00 10.55 CC5A/CD5AC048 44,000 TDR 12.00 - 12.00 10.40 CC5A/CD5AW060 45,500 TDR 12.50 - 12.50 10.85 CD5AA048 44,500 TDR 12.00 - 12.00 10.55 CK3BA048 44,500 TDR 12.00 - 12.00 10.60 CK3BA060 45,000 TDR 12.00 - 12.00 10.45 CK5A/CK5BA048 44,500 TDR 12.00 - 12.00 10.60 CK5A/CK5BA060 45,000 TDR 12.00 - 12.00 10.80 CK5A/CK5BX060 46,000 TDR 12.50 - 12.50 11.00 CK5PA048 44,500 TDR&TXV 12.00 - - 10.60 CK5PA060 45,000 TDR&TXV 12.00 - - 10.80 CK5PX060 46,000 TDR&TXV 12.50 - I - 1 11.00 COILS+355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.00 - 12.00 10.60 CC5A/CD5AW048 45,000 TDR 12.00 - 12.00 10.60 CC5A/CD5AW060 45,500 TDR 12.50 - 12.50 10.90 CK3BA060 45,000 TDR 12.00 - 12.00 10.55 CK5A/CK5BA060 45,000 TDR 12.00 - 12.00 10.85 CK5A/CK5BW048 44,500 TDR 12.00 - 12.00 10.65 See notes on page 18. -17- i COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDRt Puron TXV$ EER CK5A/CK5BX060 46,000 TDR 12.50 - 12.50 11.05 048-F CK5PA060 45,000 TDR&TXV 12.00 - - 10.85 CK5PW048 44,500 TDR&TXV 12.00 - - 10.65 CK5PX060 46,000 TDR&TXV 12.50 - - 11.05 "CK5A/CK5BA060 57,000 NONE - 12.00 12.00 1020 CC5A/CD5AA060 55,000 NONE - 11.50 11.50 9.95 CC5A/CD5AW060 58,000 NONE - 11.70 11.70 10.20 CD5PX060 58,500 TXV - 12.00 - 10.30 CE3AA060 57,000 NONE - 12.00 12.00 10.25 CK3BA060 57,000 NONE - 12.00 12.00 10.20 CK5A/CK5BT060 57,000 NONE - 12.00 12.00 10.20 CK5A/CK5BX060 58,000 NONE - 12.00 12.00 10.35 CK5PA060 57,000 TXV - 12.00 - 10.20 CK5PT060 57,000 TXV - 12.00 - 10.20 CK5PX060 58,000 TXV - 12.00 - 10.35 F(A,B)4(A,B)N(F,B,C)060 57,000 TDR 11.50 - 11.50 9.95 FB4(A,B)NB070 58,000 TDR 12.00 - 12.00 10.30 FC4(B,C)N(F,B)060 57,000 TDR&TXV 11.50 - 9.85 FC4(B,C)NB070 58,000 TDR&TXV 12.00 - 10.15 FE4ANB006 58,000 TDR&TXV 12.50 - 10.75 FG3AAA060 56,000 NONE - 11.50 11.50 10.10 FK4(C,D)NB006 58,000 TDR&TXV 12.50 12.50 10.75 FV4(A,B)NB006 58,000 TDR&TXV 12.50 10.75 FX4(A,B)NB060 56,000 TDR&TXV 12.00 - 10.15 COILS+315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 11.50 - 11.50 10.00 CD5PX060 58,500 TDR&TXV 12.00 - - 10.35 CE3AA060 58,000 TDR 12.00 - 1200, 10.35 CK3BA060 58,000 TDR 12.00 - 1200. 10.35 CK5A/CK5BA060 58,000 TDR 12.00 12.00 10.35 CK5A/CK5BT060 58,000 TDR 12.00 12.00 10.35 060-F CK5A/CK5BX060 58,000 TDR 12.00 - 12.00 10.50 CK51PA060 58,000 TDR&TXV 12.00 - - 10.35 CK5PT060 58,000 TDR&TXV 12.00 - - 10.35 CK5PX060 58,000 TDR&TXV 12.00 - - 10.45 COILS+315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12.00 - 12.00 10-20 CC5A/CD5AW060 58,000 TDR 12.00 - 12.00 10.50 CE3AA060 58,000 TDR 12.00 - 12.00 10.55 CK3BA060 58,000 TDR 12.00 -- 12.00 10.45 CK5A/CK5BA060 58,000 TDR 12.00 - 12.00 10.45 CK5A/CK5BT060 58,000 TDR 12.00 - 12.00 10.45 CK5A/CK5BX060 58,000 TDR 12.50 - 12.50 10.70 CK5PA060 58,000 TDR&TXV 12.00 - - 10.45 CK51PT060 58,000 TDR&TXV 12.00 - - 10.45 CK5PX060 58,000 TDR&TXV 12-50 - I - 1 10.70 COILS+315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12.00 12.00 10.30 CC5A/CD5AW060 57,000 TDR 1200 12.00 10.50 CD5PX060 58,500 TDR&TXV 12.50 -- - 10.65 CE3AA060 58,000 TDR 12.00 - 12.00 10.65 CK3BA060 58,000 TDR 12.00 - 12.00 10.55 CK5A/CK5BA060 58,000 TDR 12.00 - 12.00 10.55 CK5A/CK5BT060 58,000 TDR 12.00 12.00 10.55 CK5A/CK5BX060 58,000 TDR 12.50 12.50 10.75 CK5PA060 58,000 TDR&TXV 12.00 - - 10.55 CK5PT060 58,000 TDR&TXV 12.00 - - 10.55 CK5PX060 58,000 TDR&TXV 12.50 - - 10.75 " Tested combination. t In most cases,only 1 method should be used to achieve TDR function.Using more than 1 method in a system may cause degradation in performance.Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR.Most Bryant furnaces are equipped with TDR. $ TXV must be Puron®compatible and hard shutoff type. EER -Energy Efficiency Ratio SEER -Seasonal Energy Efficiency Ratio TDR -Time-Delay Relay TXV -Puron®Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat.Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners.Ratings for other com- binations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. -18- DETAILED COOLING CAPACITIES' EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens* kW" Total Sens$ kW` Total Sens$ kW*' Total Sens$ kW** Total I Sens$I kW"" Total Sens$ MW. 1 Outdoor Secti•n With CKSA/CK5BA024 IndoorSection 72 19.79 10.21 1.30 19.80 10.35 1.46 19.29 10.26 1.63 18.30 9.92 1.82 17.10 9.48 2.02 15.88 9.03 2.25 67 19.16 13.22 1.29 18.44 13.04 1.44 17.33 12.60 1.62 16.22 12.14 1.80 15.10 11.69 1.99 13.95 11.23 2.19 525 63tt 17.89 12.98 1.28 16.79 12.50 1.43 15.82 12.06 1.59 14.77 11.60 1.76 13.73 11.15 1.95 12.57 10.66 2.15 62 17.51 15.79 1.27 16.45 15.32 1.43 15.53 14.88 1.59 14.56 14.41 1.76 13.74 13.74 1.95 12.86 12.86 2.16 57 16.83 16.83 1.27 16.08 16.08 1.42 15.34 15.34 1.58 14.54 14.54 1,76 13.74 13.74 1.95 12.86 12.86 2.16 72 19.81 10.35 1.34 19.84 10.60 1.49 19.50 10.65 1.66 18.61 10.40 1.85 17.43 10.00 2.05 16.18 9.55 2.28 67 19.29 13.73 1.32 18.81 13.81 1.47 17.74 13.46 1.64 16.54 12.99 1.84 15.41 12.54 2.03 14.24 12.08 2.23 600 63tt 18.26 13.69 1.31 17.24 13.32 1.46 16.16 12.85 1.63 15.11 12.41 1.80 14.02 11.94 1.98 12.84 11,45 2.19 62 18.03 16.94 1.30 16.97 16.50 1.46 16.03 16.03 1.62 15.24 15.24 1.80 14.38 14.38 2.00 13.45 13.45 2.21 57 17.74 17.74 1.30 16.87 16.87 1.46 16.05 16.05 1.63 15.24 15.24 1.80 14.37 14.37 2.00 13.45 13.45 2.21 72 19.82 10.51 1.36 19.79 10.76 1.52 19.60 10.97 1.69 18.81 10.83 1.88 17.66 10.48 2.08 16.38 10.04 2.30 67 19.30 14.10 1.35 19.01 14.46 1.50 18.03 14.23 1.67 16.84 13.82 1.87 15.67 13.36 2.06 14.45 12.88 2.27 675 63tt 18.47 14.29 1.34 17.56 14.08 1.49 16.44 13.62 1.66 15.36 13.17 1.83 14.23 12.70 2.02 13.04 12.19 2.23 62 18.40 17.89 1.34 17.56 17.56 1.49 16.67 1 16.67 1.67 15.80 15.80 1.85 14.90 14.90 2.04 13.97 13.97 2.26 57 18.34 18.34 1.33 17.56 17.56 1.49 16.67 16.67 1.67 15.80 15.80 1.85 14.90 14.90 2.04 13.97 13.97 2.26 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 018 0.98 1.02 CC5A/CD5AW 024 1.00 0.91 024 1.00 1.01 CEMA 024 1.00 0.91 CC6A/CD5AW 024 1.00 1.01 CK313A 024 1.00 0.90 CE3AA 024 1.00 1.00 CK5A/CK5BA 018 0.98 0.90 CF5AA 024 1.00 1.00 024 1.00 0.90 CK313A 024 1.00 1.00 CK5A/CK5BW 024 1.00 0.90 CK5A/CK5BA 018 0.98 1.00 CK5PA 018 0.98 0.92 024 1.00 1.00 024 1.00 0.91 CK5A/CK5BW 024 1.00 1.00 CK5PW 024 1.00 0.91 CK5PA 018 0.98 1.00 COILS+315(A,J)AV048090 VARIABLE SPEED FURNACE 024 1.00 1.00 CC5A/CD5AW 024 1.00 0.91 CKSPW 024 1.00 1.00 CE3AA 024 1.00 0.91 F(A,B)4(A,B)N(F,C) 018 0.98 1.00 CK3BA 024 1.00 0.90 024 1.00 0.99 CK5A/CK5BA 018 0.98 0.90 FC4(B,C)NF 024 1.01 1.00 024 1.00 0.91 FE4ANF 002 1.03 0.91 CK5A/CK5BW 1 024 1 1.00 0.91 FF1 DNA 018 0.98 0.97 CK5PA 018 0.98 0.92 FF1DNA 024 1.00 1.00 024 1.00 0.91 FG3AAA 024 1.00 1.02 CK5PW 024 1.00 0.91 FK4(C,D)NF 001 1.01 0.89 COILS+355MAV042060 VARIABLE SPEED FURNACE 002 1.03 0.91 CC5A/CD5AW 024 1.00 0.92 FV4(A,B)NF 002 1.03 0.91 CE3AA 024 1.00 0.92 FX4(A,B)NF 018 1.01 1.00 CK5A/CK5BW 024 1.00 0.91 COILS+315(A,J)AV036070 VARIABLE SPEED FURNACE CK5PW 024 1.00 0.91 CC5A/CD5AA 018 0.98 0.92 - - - 024 1.00 0.91 See notes on page 30. -19- DETAILED COOLING CAPACITIES* continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 1 115 125 Capacity ITotal Capacity Total Capacity ITotal Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht I Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total ISenst kW** Total ISenstj kW** Total jSensl kW** I Total Sens# kW** Total ISenst M, 1 Outdoor Section With CK5A/CK5BA030 Indoor Section 57 22.07 22.07 1.63 21.10 21.10 1.84 20.07 20.07 2.08 18.98 18.98 2.33 17.84 17.84 2.61 16.57 16.57 2.91 700 62 22.81 20.78 1.63 21.49 20.17 1.85 20.24 19.57 2.08 18.95 18.95 2.33 17.84 17.84 2.61 16.57 16.57 2.91 67 25.23 17.55 1.64 23.98 17.11 1.86 22.53 16.54 2.11 21.03 15.93 2.38 19.47 15.30 2.66 17.81 14.65 2.95 72 26.57 13.74 1.66 26.09 13.70 1.88 24.99 13.36 2.13 23.58 12.86 2A0 22.00 12.28 2.68 20.25 11.66 2.99 57 23.21 23.21 1.66 22.07 22.07 1.89 20.97 20.97 2.13 19.88 19.88 2.40 18.65 18.65 2.67 17.33 17.33 2.98 800 62 23.51 22.30 1.67 22.14 21.70 1.89 20.97 20.97 2.13 19.88 19.88 2.40 18.64 18.64 2.67 17.35 17.35 2.98 67 25.61 18.42 1.68 24.47 18.13 1.90 23.00 17.62 2.15 21.48 17.04 2.42 19.84 16.41 2.71 18.19 15.76 3.01 72 26.62 14.00 1.70 1 26.29 14.12 1 1.92 12529, 13.88 2.17 1 23.88 13.42 2.44 22.29 12.88 2.72 20.51 12.27 3.03 57 24.04 24.04 1.70 22.93 22.93 1.93 21.80 21.80 2.19 20.58 20.58 2.45 19.32 19.32 2.73 17.99 17.99 3.05 900 62 24,08 23.62 1.71 22.93 22.93 1.93 21.79 21.79 2.19 20.57 20.57 2.46 19.32 19.32 2.73 17.99 17.99 3.05 67 25.80 19.11 1.72 24.77 19.02 1.94 23.33 18.61 2.19 21.81 18.07 2.45 20.21 17.48 2.75 18.46 16.79 3.05 72 26.66 14.25 1.73 1 26.38 14.46 1.96 25.42 14.30 2.21 24.05 13.90 2.48 22.47 13.40 2.76 20.68 12.80 3.07 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 024 0.99 1.01 CK5A/CK5BA 024 0.97 0.89 030 1.00 1.01 030 0.98 0.96 CC5A/CD5AW 024 0.99 1.01 CK5A/CK5BW 024 0.97 0.89 030 1.00 1.01 030 0.98 0.89 CE3AA 024 0.99 1.00 CK5PA 024 0.97 0.89 030 1.00 1.00 030 0.98 1 0.90 CF5AA 024 0.99 1.01 CK5PW 024 0.97 1 0.89 CK313A 024 0.99 1.00 030 0.98 1 0.90 030 1.00 1.00 COILS+315(A,J)AV048090 VARIABLE SPEED FURNACE CK5A/CK5BA 024 0.99 1.00 CC5A/CD5AA 024 0.97 0.90 030 1.00 1.00 030 0.98 0.89 CK5A/CK5BW 024 0.99 1.00 CC5A/CD5AW 024 0.97 0.89 030 1.00 1.00 030 0.98 0.89 CK5PA 024 0.99 1.00 CEMA 024 0.97 0.89 030 1.00 1.00 030 0.98 0.89 CK5PW 024 0.99 1.00 CK3BA 024 0.97 0.87 030 1.00 1.00 030 0.98 0.88 F(A,B)4BN(F,C) 024 1.00 1.00 CK5A/CK5BA 024 0.97 0.88 030 1.02 1.00 030 0.98 0.89 FC4CNF 024 1.00 1.00 CK5A/CK5BW 024 0.97 0.88 030 1.02 1.00 030 0.98 0.89 FE4ANF 002 1.01 0.90 CK5PA 024 0.97 0.88 003 1.03 0.90 030 0.98 0.89 FFIDNA 024 1.00 1.01 CK5PW 024 0.97 0.88 030 1.02 1.02 030 0.98 0.89 FF1 DNE 024 1.00 1.01 COILS+315(A,J)AV060110 VARIABLE SPEED FURNACE 030 1.02 1.02 CC5A/CD5AW 024 0.97 0.90 FG3AAA 024 0.96 0.99 030 0.98 0.90 FK4DNF 001 1.00 0.90 CE3AA 024 0.97 0.90 002 1.01 0.90 030 0.98 0.89 003 1.03 0.90 CK3BA 024 0.97 0.88 FV4BNF 002 1.01 0.90 030 0.98 0.89 003 1.03 0.90 CK5A/CK5BW 024 0.97 0.89 FX4BNF 1 030 1 1.02 0.99 030 0.98 0.89 COILS+315(A,J)AV036070 VARIABLE SPEED FURNACE CK5PW 024 0.97 0.89 CC5A/CD5AA 024 0.97 0.91 030 0.98 0.89 030 0.98 0.90 COILS+315(A,J)AV066135 VARIABLE SPEED FURNACE CC5A/CD5AW 024 0.97 0.90 CE3AA 024 0.97 0.90 030 0.98 0.90 030 0.98 0.89 CE3AA 024 0.97 0.90 COILS+315(A,J)AV066155 VARIABLE SPEED FURNACE 030 0.98 0.90 CE3AA 024 0.97 0.89 CK313A 024 0.97 0.88 030 0.98 1 0.89 030 0.98 1 0.89 - - - See notes on page 30. -20- DETAILED COOLING CAPACITIES* continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 1 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens# kW** Total Sens$ kW** Total Sens$ kW** Total Sens# kW** Total Sens$ kW** Total Sens$ kW** 124-G Outdoor Secti• 1 1 Indoor Section • • 57 22.07 22.07 1.63 21.10 21.10 1.84 20.07 20.07 2.08 18.98 18.98 2.33 17.84 17.84 2.61 16.57 16.57 2.91 700 62 22.81 20.78 1.63 21.49 20.17 1.85 20.24 19.57 2.08 18.95 18.95 2.33 17.84 17.84 2.61 16.57 16.57 2.91 67 25.23 17.55 1.64 23.98 17.11 1.86 22.53 16.54 2.11 21.03 15.93 2.38 19.47 15.30 2.66 17.81 14.65 2.95 72 26.57 13.74 1.66 26.09 13.70 1.88 24.99 13.36 2.13 23.58 12.86 2.40 22.00 12.28 2.68 20.25 11.66 2.99 57 23.21 23.21 1.66 22.07 22.07 1.89 20.97 20.97 2.13 19.88 19.88 2.40 18.65 18.65 2.67 17.33 17.33 2.98 800 62 23.51 22.30 1.67 22.14 21.70 1.89 20.97 20.97 2.13 19.88 19.88 2.40 18.64 18.64 2.67 17.35 17.35 2.98 67 25.61 18.42 1.68 24.47 18.13 1.90 23.00 17.62 2.15 21.48 17.04 2.42 19.84 16.41 2.71 18.19 15.76 3.01 72 1 26.62 1 14.001 1.70 1 26.29 1 14.12 1 1.92 1 25.291 13.88 1 2.17 1 23.881 13.42 1 2.44 1 22.29 1 12.881 2.72 1 20.51 1 12.27 1 3.03 57 24.04 24.04 1.70 22.93 22.93 1.93 21.80 21.80 2.19 20.58 20.58 2.45 19.32 19.32 2.73 17.99 17.99 3.05 900 62 24.08 23.62 1.71 22.93 22.93 1.93 21.79 21.79 2.19 20.57 20.57 2.46 19.32 19.32 2.73 17.99 17.99 3.05 67 25.80 19.11 1.72 24.77 19.02 1.94 23.33 18.61 2.19 21.81 18.07 2.45 20.21 17.48 2.75 18.46 16.79 3.05 72 26.66 14.25 1.73 26.38 14.46 1.96 25.42 14.30 2.21 24.05 13.90 2.48 22.47 13.40 2.76 20.68 12.80 3-07 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power COILS+355MAV042040 VARIABLE SPEED FURNACE CK5PW 024 0.97 0.89 CE3AA 1 024 1 0.97 1 0.90 030 1.01 0.92 030 1 0.98 10.90 COILS+355MAV060080 VARIABLE SPEED FURNACE COILS+355MAV042060 VARIABLE SPEED FURNACE CC5A/CD5AW 024 0.97 0.90 CC5A1CD5AA 024 0.97 0.90 030 0.98 0.90 030 0.98 0.90 CE3AA 024 0.97 0.90 CC5A/CD5AW 024 0.97 0.90 030 0.98 0.89 030 0.98 0.90 CK313A 024 0.97 0.88 CE3AA 024 0.97 0.89 030 0.98 0.89 030 0.98 0.89 CK5A/CK5BW 024 0.97 0.89 CK313A 024 0.97 0.88 030 0.98 0.89 030 0.98 0.89 CK5PW 024 0.97 0.89 CK5A/CK5BA 024 0.97 0.89 030 0.98 0.89 030 0.98 0.89 COILS+355MAV060100 VARIABLE SPEED FURNACE CK5A/CK5BW 024 0.97 0.89 CC5A/CD5AW 024 0.97 0.90 030 0.98 0.89 030 0.98 0.90 CK5PA 024 0.97 0.89 CE3AA 024 0.97 0.89 030 0.98 0.90 030 0.98 0.89 CK5PW 024 0.97 1 0.89 CK313A 024 0.97 0.88 030 0.98 10.89 030 0.98 0.89 COILS+355MAV042080 VARIABLE SPEED FURNACE CK5A/CK58W 024 0.97 0.89 CC5A/CD5AW 024 0.97 0.90 030 0.98 0.89 030 0.98 0.90 CK5PW 024 0.97 0.89 CE3AA 024 0.97 0.90 330 0.98 0.89 030 0.98 0.90 COILS+355MAV060120 VARIABLE SPEED FURNACE CK3BA 024 0.97 0.88 CE3AA 024 0.97 0.90 030 0.98 0.89 030 0.98 0.90 CK5A/CK5BW 024 0.97 0.89 - - - 030 0.98 0.89 See notes on page 30. -21- t DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES'F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens* kW** Total Sens$ kW'* Total Sens$ kW** Total Sens* kW** Total Sens$ kW** 1 1 Outdoor Secti•n With, CK5A/CK5BA036 IndoorSection 72 33.5 16.5 2.19 32.4 16.3 2.43 31.0 15.8 2.69 29.5 15.3 2.99 27.7 14.7 3.32 25.7 14.0 3.69 67 31.4 21.7 2.17 30.1 21.2 2.41 28.6 20.6 2.67 26.9 19.9 2.95 24.5 19.0 3.26 21.7 17.9 3.61 875 63tt 28.8 20.9 2.15 26.6 20.0 2.37 24.4 19.0 2.61 22.0 18.0 2.88 20.5 17.4 3.19 18.8 16.7 3.54 62 28.2 26.0 2.14 26.1 25.0 2.36 24.0 23.9 2.61 22.8 22.8 2.89 21.4 21.4 3.21 19.9 19.9 3.57 57 26.7 26.7 2.13 25.1 25.1 2.35 23.6 23.6 2.60 22.8 22.8 2.89 21.9 21.9 3.22 20.0 20.0 3.57 72 33.6 17.0 2.24 32.6 16.8 2.48 31.3 16.5 2.74 29.8 16.0 3.04 28.0 15.4 3.37 26.0 14.8 3.75 67 31.8 22.8 2.22 30.4 22.4 2.46 29.0 21.9 2.72 27.4 21.3 3.01 24.8 20.3 3.32 22.0 19.3 3.66 1000 63tf 29.9 22.5 2.21 27.7 21.6 2.43 25.4 20.6 2.67 22.9 19.5 2.94 21.4 18.9 3.26 19.5 18.1 3.61 62 29.6 28.3 2.21 27.5 27.2 2.43 25.6 25.6 2.68 24.3 24.3 2.96 22.9 22.9 3.29 21.4 21.4 3.65 57 28.6 28.6 2.20 26.9 26.9 2.42 25.4 25.4 2.67 24.5 24.5 2.97 23.4 23.4 3.29 21.4 21.4 3.65 72 34.1 17.8 2.30 33.1 17.6 2.54 31.4 17.0 2.79 29.9 16.6 3.09 28.1 16.1 3.42 26.2 15.6 3.81 67 32.1 23.9 2.28 30.6 23.4 2.50 29.3 23.2 2.77 27.6 22.6 3.06 25.3 21.8 3.38 22.2 20.6 3.72 1125 63tt 30.3 23.8 2.27 28.6 23.0 2.49 26.2 22.0 2.73 23.7 21.0 3.00 22.2 20.4 3.32 20.1 19.4 3.67 62 30.3 30.0 2.26 29.0 29.0 2.49 27.0 27.0 2.74 25.7 25.7 3.03 24.3 24.3 3.36 21.9 21.9 3.71 57 30.2 30.2 2.26 28.6 28.6 2.49 27.0 27.0 2.74 26.1 26.1 3.04 24.6 24.6 3.36 21.9 21.9 3.71 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 030 0.97 1.00 CK3BA 030 0.96 0.92 036 1.00 1.00 036 0.99 0.92 CC5A/CD5AW 030 0.97 1.00 CK5A/CK5BA 030 0.96 0.92 036 1.00 1.00 036 0.99 0.92 CE3AA 030 0.97 0.98 CK5A/CK5BT 036 0.99 0.92 036 0.97 0.99 CK5A/CK5BW 030 0.96 0.92 CF5AA 036 0.99 1.00 CK5PA 030 0.97 0.93 CK3BA 030 0.97 0.99 036 0.99 0.92 036 1.00 1.00 CK5PT 036 0.99 0.92 CK5A/CK513A 030 0.97 0.99 CK5PW 1 030 0.97 0.93 036 1.00 1.00 COILS+315(A,J)AV048090 VARIABLE SPEED FURNACE CK5A/CK5BT 036 1.00 1.00 CC5A/CD5AA 030 0.96 0.91 CK5A/CK5BW 030 0.97 0.99 036 0.99 0.91 036 1.00 1.00 CC5A/CD5AW 030 0.96 0.91 CK5PA 030 0.97 0.99 036 0.99 0.91 036 1.00 1.00 CE3AA 030 0.97 0.91 CK5PT 036 1.00 1.00 036 0.99 0.91 CK5PW 030 0.97 0.99 CK3BA 030 0.96 0.90 036 1.00 1.00 036 1.00 0.91 F(A,B)4(A,B)N(F,C) 030 0.97 0.99 CK5A/CK5BA 030 0.96 0.90 036 0.98 1.01 036 1.00 0.91 FC4(B,C)NF 030 0.96 0.98 CK5AJCK51BW 030 0.96 0.90 036 0.97 1.00 036 1.00 0.91 FE4ANF 002 0.98 0.91 CK5PA 030 0.97 0.92 003 0.99 0.90 036 1.00 0.91 005 1.01 0.88 CK5PT 036 1.00 0.91 FF1DNA 030 0.98 1.00 CK5PW 030 0.97 0.92 FG3AAA 036 0.97 0.99 036 1.00 0.91 FK4(C,D)NF 001 0.97 0.90 COILS+315(A,J)AV060110 VARIABLE SPEED FURNACE 002 0.98 0.91 CC5A/CD5AA 036 0.99 0.91 003 0.98 0.88 CC5A/CD5AW 030 0.95 0.91 005 1.01 0.88 036 0.99 0.91 FV4(A,B)NF 002 0.98 0.91 CE3AA 030 0.96 0.91 003 0.99 0.90 036 0.97 0.90 005 1.01 0.88 CK3BA 030 0.96 0.90 FX4(A,B)NF 030 0.96 0.96 036 0.99 0.91 036 0.97 0.99 CK5A/CK5BA 036 0.99 0.91 COILS+315(A,J)AV036070 VARIABLE SPEED FURNACE CK5A/CK5BT 036 0.99 0.91 CC5A/CD5AA 030 0.96 0.92 CK5A/CK5BW 030 0.96 0.90 036 0.99 0.92 036 0.99 0.91 CC5A/CD5AW 030 0.96 0.92 CK5PA 036 0.99 0.92 CE3AA 030 0.97 0.92 CK5PT 036 0.99 0.92 036 0.97 0.91 - - - See notes on page 30. -22- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 1 95 1 105 1 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens# kW*" Total Sens# kW** Total Sens$ kW"• Total Sens$ kW" Total Sens# kV* Total Sens# kW- Total 1 Outdoor SectionA1 • ••r Section continued 72 33.5 16.6 2.19 32.4 16.3 2-43 31.0 15.8 2.69 29.5 15.3 2.99 27.7 14.7 3.32 25.7 14.0 3.69 67 31.4 21.7 2.17 30.1 21.2 2.41 28.6 20.6 2.67 26.9 19.9 2.95 24.5 19.0 3.26 21.7 17.9 3.61 875 63tt 28.8 20.9 2.15 26.6 20.0 2.37 24.4 19.0 2.61 22.0 18.0 2.88 20.5 17.4 3.19 18.8 16.7 3.54 62 28.2 26.0 2.14 26.1 25.0 2.36 24.0 23.9 2.61 22.8 22.8 2.89 21.4 21.4 3.21 19.9 19.9 3.57 57 26.7 26.7 2.13 25.1 25.1 2.35 23.6 23.6 2.60 22.8 22.8 2.89 21.9 21.9 3.22 20.0 20.0 3.57 72 33.6 17.0 2.24 32.6 16.8 2.48 31.3 16.5 2.74 29.8 16.0 3.04 28.0 15.4 3.37 26.0 14.8 3.75 67 31.8 22.8 2.22 30.4 22.4 2.46 29.0 21.9 2.72 27.4 21.3 3.01 24.8 20.3 3.32 22.0 19.3 3.66 1000 63tt 29.9 22.5 2.21 27.7 21.6 2.43 25.4 20.6 2.67 22.9 19.5 2.94 21.4 18.9 3.26 19.5 18.1 3.61 62 29.6 28.3 2.21 27.5 27.2 2.43 25.6 25.6 2.68 24.3 24.3 2.96 22.9 22.9 3.29 21.4 21 A 3.65 57 28.6 28.6 2.20 26.9 26.9 2.42 25.4 25A 2.67 24.5 24.5 2.97 23.4 23.4 3.29 21.4 21.4 3.65 72 34.1 17.8 2.30 33.1 17.6 2.54 31 A 17.0 2.79 29.9 16.6 3.09 28.1 16.1 3.42 26.2 15.6 3.81 67 32.1 23.9 2.28 30.6 23.4 2.50 29.3 23.2 2.77 27.6 22.6 3.06 25.3 21.8 3.38 22.2 20.6 3.72 1125 63tt 30.3 23.8 2.27 28.6 23.0 2.49 26.2 22.0 2.73 23.7 21.0 3.00 22.2 20.4 3.32 20.1 19.4 3.67 62 30.3 30.0 2.26 29.0 29.0 2.49 27.0 27.0 2.74 25.7 25.7 3.03 24.3 24.3 3.36 21.9 21.9 3.71 57 30.2 30.2 2.26 28.6 28.6 2A9 27.0 27.0 2.74 26.1 26.1 3.04 24.6 24.6 3.36 21.9 21.9 3.71 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CK5PW 030 0.97 0.92 CK5PA 036 1.00 0.94 036 0.99 0.91 CK5PW 030 0.97 0.92 COILS+315(A,J)AV066135 VARIABLE SPEED FURNACE COILS+355MAV042080 VARIABLE SPEED FURNACE CC5A/CD5AW 036 0.99 0.91 CC5A/CD5AW 030 0.97 0.96 CE3AA 030 0.96 0.90 036 1.00 0.93 036 0.97 0.91 CK5A/CK5BW 030 0.97 0.92 CK5A/CK5BW 036 0.99 0.91 036 1.00 0.92 CK5PW 036 0.99 0.91 CK5PW 030 0.97 0.92 COILS+315(A,J)AV066155 VARIABLE SPEED FURNACE 036 1.00 0.92 CC5A/CD5AW 036 0.97 0.89 COILS+355MAV060080 VARIABLE SPEED FURNACE CE3AA 030 0.96 0.90 CC5A/CD5AW 030 0.97 0.96 036 0.97 0.90 036 1.00 0.95 CK5A/CK5BW 036 0.99 0.91 CK5A/CK5BW 030 0.97 0.92 CK5PW 036 0.99 0.91 036 1.00 0.92 COILS+355MAV042040 VARIABLE SPEED FURNACE CK5PW 030 0.97 0.92 CC5A/CD5AW 030 0.97 0.95 036 1.00 0.92 036 1.00 0.94 COILS+355MAV060100 VARIABLE SPEED FURNACE CK5A/CK5BW 030 0.97 0.92 CC5A/CD5AW 030 0.97 0.92 036 1.00 0.92 036 1.00 0.92 CK5PW 030 0.97 0.92 CK5A/CK5BW 030 0.97 0.92 036 1.00 0.92 036 1.00 0.92 COILS+355MAV042060 VARIABLE SPEED FURNACE CK5PW 030 0.97 0.92 CC5A/CD5AA 036 1.00 0.95 036 1.00 0.92 CC5A/CD5AW 030 0.97 0.95 COILS+355MAV060120 VARIABLE SPEED FURNACE CK313A 030 0.97 0.95 CC5A/CD5AW 036 1.00 0.92 036 1.00 0.94 1 CK5A/CK5BW 036 1.00 0.92 CK5A/CK5BA 036 1.00 0.94 CK5PW 036 1.00 0.92 CK5A/CK5BW 030 0.97 0.92 - - - See notes on page 30. -23- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens kW** Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** Total ISenst kW** 552AN036-G Outdoor Section With CK5A/CK5BA042 Indoor Section 72 40.4 19.9 2.65 39.0 19.5 2.96 37.3 18.9 3.29 35.3 18.2 3.66 33.3 17.6 4.08 30.8 16.8 4.53 67 38.2 26.0 2.63 36.3 25.3 2.93 34.5 24.6 3.25 32.5 23.9 3.62 30.4 23.1 4.01 26.5 21.6 4.41 1050 63tt 35.9 25.7 2.62 34.1 24.9 2.91 32.0 23.9 3.23 29.7 23.0 3.57 26.9 21.8 3.94 23.7 20.4 4.33 62 35.4 31.9 2.61 33.4 30.9 2.90 31.4 30.0 3.22 29.2 28.9 3.56 27.2 27.2 3.94 24.7 24.7 4.36 57 33.5 33.5 2.59 31.6 31.6 2.87 29.7 29.7 3.19 28.7 28.7 3.55 27.2 27.2 3.94 24.6 24.6 4.35 72 41.0 20.6 2.72 39.5 20.2 3.02 37.8 19.7 3.36 35.8 19.1 3.73 33.7 18.5 4.15 31.1 17.7 4,61 67 38.6 27.4 2.69 36.7 26.6 2.98 35.0 26.1 3.32 33.0 25.5 3.69 30.8 24.7 4.09 26.8 23.2 4.48 1200 63tj 36.5 27.1 2.68 34.7 26.4 2.98 32.5 25.5 3.29 30.2 24.5 3.64 27.3 23.3 4.00 24.0 21.9 4.40 62 36.2 34.2 2.68 34.2 33.2 2.97 32.2 32.1 3.29 30.3 30.3 3.64 28.1 28.1 4.02 25.5 25.5 4.44 57 35.7 35.7 2.67 33.7 33.7 2.96 31.8 31.8 3.28 30.7 30.7 3.65 28.4 28.4 4.03 25.6 25.6 4.44 72 41.3 21.2 2.78 39.8 20.9 3.08 38.1 20.4 3.42 36.1 19.8 3.79 34.0 19.3 4.21 31.4 18.6 4.68 67 38.8 28.4 2.75 37.1 27.9 3.05 35.4 27.6 3.38 33.5 27.1 3.75 31.2 26.3 4.15 27.1 24.7 4.55 1350 63ti 36.9 28.5 2.74 35.2 27.9 3.04 32.9 26.9 3.35 30.5 25.9 3.70 27.6 24.7 4.07 24.3 23.3 4.47 62 36.7 35.9 2.73 35.0 34.9 3.03 33.6 33.6 3.37 31.8 31.8 3.73 29.6 29.6 4.11 26.4 26.4 4.53 57 36.6 36.6 2.73 35.2 35.2 3.03 33.6 33.6 3.37 31.8 31.8 3.73 29.4 29.4 4.11 26.4 26.4 4.53 Multipliers for Determining the Performance With Other Indoor Sections Indoor Co ling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1.00 1.00 CK5A/CK5BE 042 0.99 0.92 042 1.00 1.00 CK5A/CK5BT 036 0.99 0.94 CC5A/CD5AW 036 1.00 1.00 CK5PA 036 0.99 0.94 042 0.99 1.00 CK51PE 042 0.99 0.93 CE3AA 036 0.99 1.00 CK5PT 036 0.99 0.94 042 1.00 1.00 COILS+315(A,J)AV048090 VARIABLE SPEED FURNACE CF5AA 036 0.99 1.00 CC5A/CD5AA 036 0.99 0.92 CK36A 036 1.00 1.00 042 0.99 0.91 042 1.00 1.00 CC5A/CD5AW 036 0.99 0.92 CK5A/CK5BA 036 1.00 1.00 CE3AA 036 0.98 0.92 042 1.00 1.00 042 0.99 0.91 CK5A/CK5BT 036 1.00 1.00 CK313A 036 0.99 0.92 042 1.00 1.00 042 0.99 0.91 CK5A/CK5BW 036 1.00 1.00 CK5A/CK5BA 036 0.99 0.92 CK5PA 036 1.00 1.00 042 0.99 0.91 042 1.00 1.00 CK5A/CK5BE 042 0.99 0.91 CK5PT 036 1.00 1.00 CK5A/CK5BT 036 0.99 0.92 042 1.00 1.00 042 0.99 0.91 CK5PW 036 1.00 1.00 CK5A/CK5BW 036 0.99 0.92 F(A,B)4(A,B)N(F,B,C) 042 1.00 1.00 CK5PA 036 0,99 0.92 F(A,B)4(A,B)N(F,C) 036 0.97 1.00 042 0.99 0.92 FC4(8,C)N(F,B) 042 0.97 0.98 CK5PE 042 0.99 0.91 FC4(B,C)NB 054 1.00 0.95 CK5PT 036 0.99 0.92 FC4(B,C)NF 036 0.96 1.00 042 0.99 0.92 FE4ANB 006 1,02 0.88 CK5PW 036 1 0,99 1 0.92 FE4ANF 002 0.97 0.93 COILS+315(A,J)AV060110 VARIABLE SPEED FURNACE 003 0.98 0.90 CC5A/CD5AA 036 0.98 0.92 005 1.00 0.88 042 0.98 0.91 FG3AAA 036 0.97 0.99 CC5A/CD5AW 036 0.98 0.92 FK4(C,D)NB 006 1.01 0.87 042 0.97 0.91 FK4(C,D)NF 001 0.97 0.93 CE3AA 036 0.97 0.92 002 0.97 0.93 042 0.99 0.92 003 0.98 0.90 CK3BA 036 0.99 0.92 005 1.00 0.88 042 0.99 0.92 FV4(A,B)NB 006 1.02 0.88 CK5A/CK5BA 036 0.99 0.92 FV4(A,B)NF 002 0.97 0.93 042 0.99 0.92 003 0.98 0.90 CK5A/CK5BE 042 0.99 0.91 005 1.00 0.88 CK5A/CK5BT 036 0.99 0.92 FX4(A,B)NF 036 0.97 1.00 042 0.99 0.92 042 1 0.97 0.97 CK5A/CK5BW 036 0.99 0.92 COILS+315(A,J)AV036070 VARIABLE SPEED FURNACE CK5PA 036 0.99 0.93 CC5A/CD5AA 036 0.99 0.94 042 0.99 0.92 CE3AA 036 0.98 0.94 CK5PE 042 0.99 0.92 042 0.99 0.93 CK5PT 036 0.99 1 0.93 CK313A 036 0.99 0.94 042 0.99 0.92 CK5A/CK5BA 036 0.99 0.94 CK5PW 036 0.99 0.92 See notes on page 30. -24- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** Total I Sens$I kW** I Total ISenstl kW** 1 . Outdoor Secti•n With CK5A/CK5BA042 Indoor • • • 72 40.4 19.9 2.65 39.0 19.5 2.96 37.3 18.9 3.29 35.3 18.2 3.66 33.3 17.6 4.08 30.8 16.8 4.53 67 38.2 26.0 2.63 36.3 25.3 2.93 34.5 24.6 3.25 32.5 23.9 3.62 30.4 23.1 4.01 26.5 21.6 4.41 1050 63tt 35.9 25.7 2.62 34.1 24.9 2.91 32.0 23.9 3.23 29.7 23.0 3.57 26.9 21.8 3.94 23.7 20.4 4.33 62 35.4 31.9 2.61 33.4 30.9 2.90 31.4 30.0 3.22 29.2 28.9 3.56 27.2 27.2 3.94 24.7 24.7 4.36 57 33.5 33.5 2.59 31.6 31.6 2.87 29.7 29.7 3.19 28.7 28.7 3.55 27.2 27.2 3.94 24.6 24.6 4.35 72 41.0 20.6 2.72 39.5 20.2 3.02 37.8 19.7 3.36 35.8 19.1 3.73 33.7 18.5 4.15 31.1 17.7 4.61 67 38.6 27.4 2.69 36.7 26.6 2.98 35.0 26.1 3.32 33.0 25.5 3.69 30.8 24.7 4.09 26.8 23.2 4.48 1200 63tt 36.5 27.1 2.68 34.7 26.4 2.98 32.5 25.5 3.29 30.2 24.5 3.64 27.3 23.3 4.00 24.0 21.9 4.40 62 36.2 34.2 2.68 34.2 33.2 2.97 32.2 32.1 3.29 30.3 30.3 3.64 28.1 28.1 4.02 25.5 25.5 4.44 57 35.7 35.7 2.67 33.7 33.7 2.96 31.8 31.8 3.28 30.7 30.7 3.65 28.4 28.4 4.03 25.6 25.6 4.44 72 41.3 21.2 2.78 39.8 20.9 3.08 38.1 20.4 3.42 36.1 19.8 3.79 34.0 19.3 4.21 31.4 18.6 4.68 67 38.8 28.4 2.75 37.1 27.9 3.05 35.4 27.6 3.38 33.5 27.1 3.75 31.2 26.3 4.15 27.1 24.7 4.55 1350 63tt 36.9 28.5 2.74 35.2 27.9 3.04 32.9 26.9 3.35 30.5 25.9 3.70 27.6 24.7 4.07 24.3 23.3 4.47 62 36.7 35.9 2.73 35.0 34.9 3.03 33.6 33.6 3.37 31.8 31.8 3.73 29.6 29.6 4.11 26.4 26.4 4.53 57 36.6 36.6 2.73 35.2 35.2 3.03 33.6 33.6 3.37 31.8 31.8 3.73 29.4 29.4 4.11 26.4 26.4 4.53 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power COILS+315(A,J)AV066135 VARIABLE SPEED FURNACE CK3BA 036 0.99 0.94 CC5A/CD5AA 042 0.99 0.91 042 0.99 0.93 CC5A/C05AW 036 0.99 0.92 CK5A/CK5BA 036 0.99 0.94 042 0.98 0.91 CK5PA 036 0.99 0.94 CE3AA 036 0.98 0.92 COILS+355MAV042080 VARIABLE SPEED FURNACE 042 0.99 0.91 CC5A/CD5AA 042 0.99 0.93 CK313A 042 0.99 0.91 CC5A/CD5AW 036 0.99 0.93 CK5A/CK5BA 042 0.99 0.91 CK313A 042 0.99 0.93 CK5A/CK5BT 042 0.99 0.91 CK5A/CK5BA 042 0.99 0.92 CK5A/CK5BW 036 0.99 0.92 CK5A/CK5BW 036 0.99 0.93 CK5PA 042 0.99 0.91 CK5PA 042 0.99 0.92 CK5PT 042 0.99 0.91 CK5PW 036 1 0.99 1 0.93 CK5PW 036 0.99 0.92 COILS+355MAV060080 VARIABLE SPEED FURNACE COILS+315(A,J)AV066155 VARIABLE SPEED FURNACE CC5A/CD5AA 042 0.99 0.94 CC5A/CD5AA 042 0.99 0.90 CC5A/CD5AW 036 0.99 0.94 CC5A/CD5AW 036 0.99 0.92 CK3BA 042 0.99 0.93 042 0.98 0.90 CK5A/CK5BA 042 0.99 0.93 CE3AA 036 0.98 0.92 CK5A/CK5BW 036 0.99 0.94 042 0.99 0.90 CK5PA 042 0.99 0.93 CK313A 042 0.99 0.90 CK51YW 1 036 0.99 1 0.94 CK5A/CK6BA 042 0.99 0.90 COILS+355MAV060100 VARIABLE SPEED FURNACE CK5A/CK5BT 042 0.99 0.90 CC5A/CD5AA 042 0.99 0.91 CK5A/CK5BW 036 0.99 0.91 CC5A/CD5AW 036 0.99 0.91 CK5PA 042 0.99 0.91 CK3BA 042 0.99 0.91 CK5PT 042 0.99 0.91 CK5A/CK5BA 042 0.99 0.91 CKSPW 036 0.99 0.91 CK5A/CK5BW 036 0.99 0.91 COILS+355MAV042040 VARIABLE SPEED FURNACE CK5PA 042 0.99 0.91 CC5A/CD5AA 042 0.99 0.93 CK5PW 036 0.99 0.91 CC5A/CD5AW 036 0.99 0.94 COILS+355MAV060120 VARIABLE SPEED FURNACE CK5A/CK5BA 042 0.99 0.93 CC5A/CD5AA 042 0.99 0.91 CK5A/CK5BW 036 0.99 0.94 CC5A/CD5AW 036 0.99 0.92 CK5PA 042 0.99 6.93 CK5A/CK5BA 042 0.99 0.91 CK5PW 036 0.99 0.94 CK5A/CK5BW 036 0.99 0.92 COILS+355MAV042060 VARIABLE SPEED FURNACE CK5PA 042 0.99 0.91 CC5A/CD5AA 1 036 0.99 0.94 CK5PW 1 036 1 0.99 1 0.92 See notes on page 30. -25- R � � DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 Cn 105 115 125 Capacity Total Capacity Total CaTotal Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MSys MBtuht - Sys MBtuht Sys MBtuht Sys CFM EW13 Total Sens$ kW** Total Sens$ kW** TotakW** Total Sena# kW** Total Sens$ kW?* Total Sens$ kW** 552AN042-F Outdoor Section With CK5A/CK5BA048 Indoor Section 72 46.2 22.9 3.13 44.9 22.5 3.49 42.8 21.8 3.88 40.4 21.0 4.31 37.9 20.2 4.78 35.1 19.3 5.33 67 43.8 30.2 3.10 41.7 29.4 3.44 39.5 28.5 3.82 37.1 27.6 4.24 33.5 26.1 4.68 29.4 24.6 5.17 1225 63tt 38.4 28.3 3.03 35.6 27.1 3.34 32.7 25.9 3.70 31.0 25.2 4.11 29.2 24.4 4.58 25.6 23.0 5.06 62 37.9 35.5 3.02 35.2 34.2 3.34 32.7 32.7 3.69 31.3 31.3 4.12 29.8 29.8 4.59 27.7 27.7 5.12 57 37.1 37.1 3.00 34.9 34.9 3.33 32.7 32.7 3.70 31.7 31.7 4.13 30.4 30.4 4.61 27.7 27.7 5.12 72 46.8 23.7 3.21 45.0 23.2 3.56 43.0 22.5 3.95 40.7 21.8 4.38 38.3 21.2 4.87 35.4 20.3 5.41 67 44.3 31.8 3.18 42.1 30.8 3.51 40.0 30.2 3.90 37.6 29.4 4.33 33.9 27.9 4.77 29.8 26.4 5.26 1400 63tj 39.6 30.3 3.11 36.7 29.1 3.43 34.0 27.9 3.79 32.3 27.2 4.21 30.4 26.5 4.68 26.8 24.9 5.16 62 39.0 38.1 3.10 36.7 36.7 3.43 35.4 35.4 3.81 34.0 34.0 4.25 32.1 32.1 4.72 28.9 28.9 5.22 57 38.6 38.6 3.10 37.4 37.4 3.44 35.2 35.2 3.81 34.1 34.1 4.25 31.9 31.9 4.72 29.1 29.1 5.23 72 47.3 24.5 3.29 45.6 24.1 3.64 43.5 23.5 4.03 41.1 22.8 4.46 38.6 22.2 4.96 35.7 21.3 5.50 67 44.7 33.2 3.25 42.2 32.1 3.58 40.2 31.7 3.97 38.0 31.0 4.40 34.6 29.8 4.85 30.4 28.2 5.35 1575 63tf 41.8 32.7 3.21 37.9 31.1 3.52 35.1 29.9 3.88 33.4 29.2 4.30 31.1 28.2 4.77 27.0 26.4 5.24 62 41.3 41.1 3.20 39.3 39.3 3.54 37.8 37.8 3.93 36.3 36.3 4.36 33.2 33.2 4.82 29.9 29.9 5.33 57 41.1 41.1 3.20 39.6 39.6 3.55 37.4 37.4 3.92 36.2 36.2 4.36 33.1 33.1 4.82 30.3 30.3 5.34 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AC 048 0.99 1.00 UK36A 042 0.98 0.92 CC5A/CD5AW 042 0.99 1.00 048 0.99 0.92 048 1.00 1.00 CK5A/CK5BA 042 0.98 0.92 CD5AA 048 1.00 1.00 048 0.99 0.92 CE3AA 042 0.99 0.99 CK5A/CK5BE 042 0.99 0.93 048 1.00 1.00 CK5A/CK5BT 042 0.98 0.92 CF5AA 048 0.99 0.99 048 0.99 0.92 CK3BA 042 0.99 0.99 CK5PA 042 0.98 0.92 048 1.00 1.00 048 0.99 0.92 CK5A/CK5BA 042 0.99 0.99 CK5PE 042 0.99 0.93 048 1.00 1.00 CK5PT 1 042 1 0.98 1 0.92 CK5A/CK5BT 042 0.99 0.99 1 048 1 0.99 0.92 048 1.00 1.00 COILS+315(A,J)AV060110 VARIABLE SPEED FURNACE CK5A/CK5BW 048 1.00 1.00 CC5A/CD5AA 042 0.98 0.93 CK5PA 042 0.99 0.99 CC5A/CD5AC 048 0.98 0.93 048 1.00 1.00 CC5A/CD5AW 042 0.96 0.92 CK5PT 042 0.99 0.99 048 0.99 0.93 048 1.00 1.00 CD5AA 048 0.99 0.93 CK513W 048 1-00 1.00 CE3AA 042 0.98 0.92 F(A,B)4(A,B)N(F,B,C) 042 0.99 1.01 048 0.99 0.93 048 1.00 1.00 CK3BA 042 0.98 0.93 FC4(B,C)N(F,B) 042 0.96 1.00 048 0.99 0.92 048 0.99 1.01 CK5A/CK5BA 042 0.98 0.93 FC4(B,C)NB 054 1.01 0.97 048 0.99 0.93 FE4ANB 006 1.01 0.89 CK5A/CK5BE 042 0.98 0.92 FE4ANF 003 0.96 0.91 CK5A/CK5BT 042 0.98 0.93 005 1.01 0.92 048 0.99 0.93 FG3AAA 048 1.00 1.00 CK5A/CK5BW 048 0.99 0.92 FK4(C,D)NB 006 1.01 0.89 CK5PA 042 0.98 0.93 FK4(C,D)NF 003 0.96 0.91 048 0.99 0.92 005 1.00 0.91 CK5PE 042 0.98 0.92 FV4(A,B)NB 006 1.01 0.89 CK5PT 042 0.98 0.93 FV4(A,B)NF 003 0.96 0.91 048 0.99 0.92 005 1.01 0.92 CK5PW 048 0.99 0.92 FX4(A,B)NF 042 096 0.98 COILS+315(A,J)AV066135 VARIABLE SPEED FURNACE 048 0.99 0.99 CC5A/CD5AA 042 0.98 0.91 COILS+315(A,J)AV048090 VARIABLE SPEED FURNACE CC5A/CD5AC 048 0.98 0.91 CC5A/CD5AA 042 0.98 0.92 CC5A/CD5AW 042 0.98 0.92 CC5A/CD5AC 048 0.98 0.92 048 0.99 0.91 CD5AA 048 0.99 0.92 CD5AA 048 0.99 0.91 CE3AA 042 0.98 0.92 CE3AA 042 0.98 0.91 048 0.99 0.92 048 0.99 0.92 See notes on page 30. -26- r. 1 DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** 1 Outdoor Secti•n With CK5A/CK513A048 Indoor • • • 72 46.2 22.9 3.13 44.9 22.5 3.49 42.8 21.8 3.88 40.4 21.0 4.31 37.9 20.2 4.78 35.1 19.3 5.33 67 43.8 30.2 3-10 41.7 29.4 3.44 39.5 28.5 3.82 37.1 27.6 4.24 33.5 26.1 4.68 29.4 24.6 5.17 1225 63tt 38.4 28.3 3.03 35.6 27.1 3.34 32.7 25.9 3.70 31.0 25.2 4.11 29.2 24.4 4.58 25.6 23.0 5.06 62 37.9 35.5 3.02 35.2 34.2 3.34 32.7 32.7 3.69 31.3 31.3 4.12 29.8 29.8 4.59 27.7 27.7 5.12 57 37.1 37.1 3.00 34.9 34.9 3.33 32.7 32.7 3.70 31.7 31.7 4.13 30.4 30.4 4.61 27.7 27.7 5.12 72 46.8 23.7 3.21 45.0 23.2 3.56 43.0 22.5 3.95 40.7 21.8 4.38 38.3 21.2 4.87 35.4 20.3 5.41 67 44.3 31.8 3.18 42.1 30.8 3.51 40.0 30.2 3.90 37.6 29.4 4.33 33.9 27.9 4.77 29.8 26.4 5.26 1400 63tt 39.6 30.3 3.11 36.7 29.1 3.43 34.0 27.9 3.79 32.3 27.2 4.21 30.4 26.5 4.68 26.8 24.9 5.16 62 39.0 38.1 3.10 36.7 36.7 3.43 35A 35.4 3.81 34.0 34.0 4.25 32.1 32.1 4.72 28.9 28.9 5.22 57 38.6 38.6 3.10 37.4 37.4 3.44 352 35.2 3.81 34.1 34.1 4.25 31.9 31.9 4.72 29.1 29.1 5.23 72 47.3 24.5 3.29 45.6 24.1 3.64 43.5 23.5 4.03 41.1 22.8 4.46 38.6 22.2 4.96 35.7 21.3 5.50 67 44.7 33.2 3.25 42.2 32.1 3.58 40.2 31.7 3.97 38.0 31.0 4.40 34.6 29.8 4.85 30.4 28.2 5.35 1575 63tt 41.8 32.7 3.21 37.9 31.1 3.52 35.1 29.9 3.88 33.4 29.2 4.30 31.1 28.2 4.77 27.0 26.4 5.24 62 41.3 41.1 3.20 39.3 39.3 3.54 37.8 37.8 3.93 36.3 36.3 4.36 33.2 33.2 4.82 29.9 29.9 5.33 57 41.1 41.1 3.20 39.6 39.6 3.55 37.4 37.4 3.92 36.2 36.2 4.36 33.1 33.1 4.82 30.3 30.3 5.34 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size CapacityPower CK36A 042 0.98 0.91 CK5A/CK513E 042 0.99 0.96 048 0.99 0.91 CK5PE 042 0.99 0.96 CK5A/CK513A 042 0.98 0.91 COILS+355MAV042080 VARIABLE SPEED FURNACE 048 0.99 0.91 CC5A/CD5AA 042 0.98 0.93 CK5A/CK5BT 042 0.98 0.91 CC5A/CD5AC 048 0.98 0.94 048 0.99 0.91 CD5AA 048 0.99 0.94 CK5A/CK5BW 048 0.99 0.91 CK38A 042 0.98 0.93 CK5PA 042 0.98 0.91 048 0.99 0.93 048 0.99 0.91 CK5A/CK5BA 042 0.98 0.93 CK5PT 042 0.98 0.91 048 0.99 0.93 048 0.99 0.91 CK5PA 042 0.98 0.93 CK5PW 048 0.99 1 0.91 048 0.99 0.93 COILS+315(A,J)AV066155 VARIABLE SPEED FURNACE COILS+355MAV060080 VARIABLE SPEED FURNACE CC5A/CD5AA 042 0.98 0.91 CCSA/CD5AA 042 0.98 0.94 CC5A/CD5AC 048 0.98 0.90 CC5A/CD5AC 048 0.98 0.95 CC5A/CD5AW 042 0.98 0.92 CD5AA 048 0.99 0.95 048 0.99 0.91 CK3BA 042 0.98 0.94 CD5AA 048 0.99 0.91 048 0.99 0.94 CE3AA 042 0.98 0.90 CK5A/CK5BA 042 0.98 0.94 048 0.99 0.91 048 0.99 0.94 CK3BA 042 0.98 0.91 CK5PA 042 0.98 0.94 048 0.99 0.91 048 0.99 0.94 CK5A/CK5BA 042 0.98 0.91 COILS+35511WAV060100 VARIABLE SPEED FURNACE 048 0.99 0.91 CC5A/CD5AA 042 0.98 0.92 CK5A/CK5BT 042 0.98 0.91 CC5A/CD5AC 048 0.98 0.93 048 0.99 0.91 CD5AA 048 0.99 0.92 CK5A/CK5BW 048 0.99 0.91 CK313A 042 0.98 0.92 CK5PA 042 0.98 0.91 048 0.99 0.92 048 0.99 0.91 CK5A/CK5BA 042 0.98 0.92 CK51PT 042 0.98 0.91 048 0.99 0.92 048 0.99 0.91 CK5PA 042 0.98 0.92 CK5PW 048 1 0.99 0.91 048 0.99 0.92 COILS+355MAV042040 VARIABLE SPEED FURNACE COILS+356MAV060120 VARIABLE SPEED FURNACE CC5A/CD5AA 042 0.98 0.94 CC5A/CD5AA 042 0.98 0.92 CC5A/CD5AW 048 0.99 0.95 CC5A/CD5AW 048 0.99 0.92 CK5A/CK5BA 042 0.98 0.94 CK5A/CK5BA 042 0.98 0.92 CK5A/CK56W 048 0.99 0.94 CK5A/CK5BW 048 0.99 0.92 CK5PA 042 0.98 0.94 CK5PA 042 0.98 0.92 CK5PW 048 0.99 0.94 CK5PW 048 0.99 0.92 COILS+355MAV042060 VARIABLE SPEED FURNACE - - - CK3BA 1 042 0.98 1 0.94 See notes on page 30. -27- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 1 15 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens$ kW** Total Sens# kW** Total Sens# kW** Total Sens$ kW** Total Sens$ kW** 1 Outdoor Section With CK5A/CK5BA060 Indoor 72 53.9 26.9 3.58 51.7 26.2 3.98 49.2 25.4 4.42 46.4 24.5 4.90 43.6 23.6 5.45 40.3 22.5 6.07 67 50.4 35.1 3.52 48.0 34.2 3.90 45.4 33.2 4.34 42.8 32.3 4.82 39.5 31.1 5.35 34.7 29.2 5.90 1400 63tj 47.3 34.5 3.48 44.9 33.5 3.85 42.4 32.4 4.28 38.8 30.9 4.73 34.8 29.2 5.22 30.0 27.2 5.75 62 46.7 43.1 3.46 44.4 42.0 3.84 41.7 40.7 4.26 39.0 39.0 4.73 36.0 36.0 5.25 32.3 32.3 5.82 57 45.4 45.4 3.44 42.8 42.8 3.82 40.1 40.1 4.23 38.4 38.4 4.72 35.5 35.5 5.24 32.3 32.3 5.83 72 54.1 27.7 3.66 52.0 27.0 4.06 49.6 26.4 4.50 47.1 25.7 5.01 44.2 24.9 5.56 40.6 23.8 6.18 67 50.8 36.8 3.60 48.6 36.2 3.99 46.0 35.4 4.43 43.4 34.5 4.92 40.1 33.4 5.45 35.2 31.5 6.01 1600 63tf 47.9 36.4 3.55 45.7 35.6 3.95 43.1 34.5 4.37 39.3 33.0 4.82 35.2 31.3 5.31 30.3 29.2 5.84 62 47.7 46.2 3.56 45.4 45.0 3.94 43.0 43.0 4.37 40.4 40.4 4.85 37.2 37.2 5.37 33.3 33.3 5.95 57 47.4 47.4 3.55 44.9 44.9 3.93 43.3 43.3 4.38 41.0 41.0 4.86 37.8 37.8 5.38 34.1 34.1 5.96 72 54.7 28.7 3.75 52.6 28.1 4.15 50.3 27.7 4.60 47.4 26.8 5.09 44.4 26.1 5.64 40.9 25.0 6.28 67 51.3 38.6 3.69 49.1 38.2 4.08 46.5 37.4 4.51 43.8 36.6 5.00 40.6 35.5 5.55 35.7 33.7 6.11 1800 63tt 48.4 38.2 3.64 46.2 37.6 4.03 43.6 36.6 4.46 40.1 35.1 4.92 35.6 33.2 5,40 30.8 30.8 5.94 62 48.7 48.6 3.65 46.4 46.4 4.03 44.4 44.4 4.47 42.2 42.2 4.97 38.5 38.5 5.49 34.4 34.4 6.07 57 48.5 48.5 3.64 46.4 46.4 4.03 44.3 44.3 4.47 42.2 42.2 4.97 39.6 39.6 5,51 35.2 35.2 6.09 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.98 1.00 CEMA 048 0.97 0.95 CC5A/CD5AC 048 0.96 0.99 060 0.98 0.93 CC5A/CD5AW 048 0.98 1.00 CK313A 048 0.97 0.95 060 1.01 1.02 CK5A/CK5BA 048 0.97 0.95 CD5AA 048 0.98 1.00 CK5A/CK5BT 048 0.97 0.95 CE3AA 048 0.98 0.99 CK5PA 048 0.97 0.95 060 1.00 1.00 CK5PT 048 0.97 0.95 CF5AA 048 0.96 0.98 COILS+315(A,J)AV060110 VARIABLE SPEED FURNACE CK3BA 048 0.98 1.00 CC5A/CD5AA 060 0.97 0.95 060 1.00 1.00 CC5A/CD5AC 048 0.95 0.95 CK5A/CK5BA 048 0.98 1.00 CC5A/CD5AW 048 0.97 0.95 060 1.00 1.00 CD5AA 048 0.97 0.95 CK5A/CK5BT 048 0.98 1.00 CD5PX 060 0.99 0.94 060 1.00 1.00 CE3AA 048 0.97 0.95 CK5A/CK5BW 048 0.98 1.00 060 0.98 0.93 CK5A/CK5BX 060 1.01 1.00 CK313A 048 0.97 0.95 CK5PA 048 0.98 1.00 060 0.98 0.93 060 1.00 1.00 CK5A/CK5BA 048 0.97 0.95 CK5PT 048 0.98 1.00 060 0.98 0.93 060 1.00 1.00 CK5A/CK5BT 048 0.97 0.95 CK5PW 048 0.98 1.00 060 0.98 0.93 CK5PX 060 1.01 1.00 CK5A/CK5BW 048 0.97 0.94 F(A,B)4(A,B)N(F,B,C) 048 0.98 1.01 CK5A/CK5BX 060 0.99 0.93 060 1.00 1.03 CK5PA 048 0.97 0.95 FB4(A,B)NB 070 1.01 1.01 060 0.98 0.93 FC4(B,C)N(F,B) 048 0.97 1.01 CK5PT 048 0.97 0.95 060 0.98 1.02 060 0.98 0.93 FC4(B,C)NB 054 0.98 0.98 CK5PW 1 048 0.97 0.94 070 100 1.01 CK5PX 1 060 0.99 0.93 FE4ANB 006 1.00 0.92 COILS+315(A,J)AV066135 VARIABLE SPEED FURNACE FE4ANF 005 0.98 0.92 CC5A/CD5AA 060 0.97 0.93 FG3AAA 048 0.96 0.98 CC5A/CD5AC 048 0.96 0.93 060 0.98 0.99 CC5A/CD5AW 048 0.97 0.94 FK4(C,D)NB 006 1.00 0.92 060 0.99 0.93 FK4(C,D)NF 005 0.98 0.92 CD5AA 048 0.97 0.93 FV4(A,B)NB 006 1.00 0.92 CE3AA 048 0.97 0.94 FV4(A,B)NF 005 0.98 0.92 060 0.98 0.92 FX4(A,B)NB 060 0.99 1.00 CK313A 048 0.97 0.94 FX4(A,B)NF 048 1 0.98 1.00 060 0.98 0.92 COILS+315(A,J)AV048090 VARIABLE SPEED FURNACE CK5A/CK5BA 048 0.97 0.94 CC5A/CD5AC 1 048 1 0.95 0.94 060 0.98 0.92 CD5AA 048 1 0.97 0.95 - - - See notes on page 30. -28- DE TAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys _MB_tuht Sys CFM EWB Total Sens kW** Total Sena$ kW** Total Sens$ kW*` Total Sens$ kW** Total Sena$ kW** Total Sens$ kW** 14: Outdoor Section ' : ' 1* 1 Indoor Section • • 72 53.9 26.9 3.58 51.7 26.2 3.98 49.2 25.4 4.42 46.4 24.5 4.90 43.6 23.6 5.45 40.3 22.5 6.07 67 50.4 35.1 3.52 48.0 34.2 3,90 45.4 33.2 4.34 42.8 32.3 4.82 39.5 31.1 5.35 34.7 29.2 5.90 1400 63tt 47.3 34.5 3.48 44.9 33.5 3.85 42.4 32.4 4.28 38.8 30.9 4.73 34.8 29.2 5.22 30.0 27.2 5.75 62 46.7 43.1 3.46 44.4 42.0 3.84 41.7 40.7 4.26 39.0 39.0 4.73 36.0 36.0 5.25 32.3 32.3 5.82 57 45.4 45.4 3.44 42.8 428 3.82 40.1 40.1 4.23 38.4 38.4 4.72 35.5 35.5 5.24 32.3 32.3 5.83 72 54.1 27.7 3.66 52.0 27.0 4.06 49.6 26.4 4.50 47.1 25.7 5.01 44.2 24.9 5.56 40.6 23.8 6.18 67 50.8 36.8 3.60 48.6 36.2 3.99 46.0 35.4 4.43 43.4 34.5 4.92 40.1 33.4 5.45 35.2 31.5 6.01 1600 63tt 47.9 36.4 3.55 45.7 35.6 3.95 43.1 34.5 4.37 39.3 33.0 4.82 35.2 31.3 5.31 30.3 29.2 5.84 62 47.7 46.2 3.56 45.4 45.0 3.94 43.0 43.0 4.37 40.4 40.4 4.85 37.2 37.2 5.37 33.3 33.3 5.95 57 47.4 47.4 3.55 44.9 44.9 3.93 43.3 43.3 4.38 41.0 41.0 4.86 37.8 37.8 5.38 34.1 34.1 5.96 72 54.7 28.7 3.75 52.6 28.1 4.15 50.3 27.7 4.60 47.4 26.8 5.09 44.4 26.1 5.64 40.9 25.0 6.28 67 51.3 38.6 3.69 49.1 38.2 4.08 46.5 37.4 4.51 43.8 36.6 5.00 40.6 35.5 5.55 35.7 33.7 6.11 1800 63tt 48.4 38.2 3.64 46.2 37.6 4.03 43.6 36.6 4.46 40.1 35.1 4.92 35.6 33.2 5.40 30.8 30.8 5.94 62 48.7 48.6 3.65 46.4 46.4 4.03 44.4 44.4 4.47 42.2 42.2 4.97 38.5 38.5 5.49 34.4 34.4 6.07 57 48.5 48.5 3.64 46.4 46.4 4.03 44.3 44.3 4.47 42.2 42.2 4.97 39.6 39.6 5.51 35.2 35.2 6.09 Multipliers for Determining the Performance With Other Indoor Sections Indoor Co ling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CK5A/CK5BT 048 0.97 0.94 CK5A/CK5BA 048 0.97 0.97 060 0.98 0.92 CK5PA 048 0.97 0.97 CK5A/CK5BW 048 0.97 0.94 COILS+355MAV060080 VARIABLE SPEED FURNACE CK5A/CK5BX 060 0.99 0.91 CC5A/CD5AW 060 0.99 0.98 CKSPA 048 0.97 0.93 CK3BA 048 0.97 0.98 060 0.98 0.92 060 0.98 0.97 CKSPT 048 0.97 0.93 CK5A/CK5BA 060 0.98 0.97 060 0.98 0.922 CK5AfCK5BX 060 1.00 0.97 CK5PW 048 0.97 0.93 CK5PA 060 1 0.98 1 0.97 CK5PX 060 0.99 0.91 CKSPX 060 1 1.00 10.97 COILS+315(A,J)AV066155 VARIABLE SPEED FURNACE COILS+355MAV060100 VARIABLE SPEED FURNACE CC5A/CD5AA 060 0.98 0.93 CC5A/CD5AA 060 0.97 0.95 CC5A/CD5AC 048 0.96 0.93 CC5A/CD5AC 048 0.96 0.96 CC5A/CD5AW 048 0.97 0.92 CC5A/CD5AW 060 0.99 0.95 060 0.99 0.92 CD5AA 048 0.97 0.95 CD5AA 048 0.97 0.92 CK3BA 048 0.97 0.95 CE3AA 048 0.97 0.93 060 0.98 0.97 060 0.98 0.91 CK5A/CK5BA 048 0.97 0.95 CK3BA 048 0.97 0.93 060 0.98 0.94 060 0.98 0.91 CK5A/CK5BX 060 1.00 0.95 CK5A/CK5BA 048 0.97 0.93 CK5PA 048 0.97 0.95 060 0.98 0.91 060 0.98 0.94 CK5A/CK5BT 048 0.97 0.93 CK5PX 060 1.00 0.96 060 0.98 0.91 COILS+355MAV060120 VARIABLE SPEED FURNACE CK5A/CK5BW 048 0.97 0.93 CC5A/CD5AA 060 0.97 0.95 CK5A/CK5BX 060 0.99 0.91 CC5A/CD5AW 048 0.98 0.96 CK5PA 048 0.97 0.93 060 0.99 0.94 060 0.98 0.91 CK3BA 060 0.98 0.96 CK5PT 048 0.97 1 0.93 CK5A/CK5BA 060 0.98 0.94 060 0.98 0.91 CK5A/CK5BW 048 0.97 0.94 CK5PW 1 048 1 0.97 0.93 CK5A/CK5BX 060 1.00 0.94 CKSPX 1 060 1 0.99 0.91 CK5PA 060 0.98 0.94 COILS+355MAV042080 VARIABLE SPEED FURNACE CK5PW 048 0.97 0.94 CD5AA 1 048 0.97 1 0.97 CKSPX 060 1.00 0.94 CK36A 048 0.97 0.97 - - - See notes on page 30. -29- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens$ kW** Total Sens$ kW*' Total Sens$ kW** Total Sens$ kW** Total Sens$ kW** 552AN060-F Outdoor Section With CK5A/CK5BA060 Indoor Section 72 66.5 32.5 4.51 64.0 31.7 5.03 61.2 30.7 5.60 57.9 29.6 6.25 54.3 28.3 6.97 50.2 27.0 7.76 67 62.4 41.9 4.44 59.6 40.8 4.95 56.4 39.5 5.50 53.0 38.2 6.13 49.5 36.9 6.83 43.3 34.5 7.53 1600 63tt 55.7 39.9 4.33 52.2 38.3 4.81 48.5 36.7 5.34 46.5 35.9 5.97 43.7 34.7 6.66 38.4 32.5 7.35 62 54.4 49.4 4.31 51.0 47.8 4.79 47.5 46.1 5.32 45.7 45.1 5.95 43.7 43.7 6.66 39.9 39.9 7.41 57 51.3 51.3 4.25 48.4 48.4 4.74 47.0 47.0 5.30 45.4 45.4 5.94 43.4 43.4 6.65 39.6 39.6 7.40 72 67.2 33.5 4.60 64.8 32.7 5.12 61.9 31.8 5.70 58.6 30.8 6.35 54.6 29.4 7.03 50.5 28.1 7.82 67 62.9 43.6 4.52 60.1 42.6 5.02 57.0 41.5 5.59 53-7 40.3 6,22 50.1 39.1 6.92 44.0 36.7 7.64 1800 63tf 58.6 42.9 4.46 55.0 41.3 4.94 51.2 39.7 5.47 49.2 38.8 6.11 44.4 3&8 6.76 39.2 34.7 7.47 62 57.5 53.4 4.44 54.0 51.7 4.92 50.6 50.0 5.46 48.8 48.8 6.10 45.6 45.6 6.79 41.6 41.6 7.55 57 54.7 54.7 4.39 51.8 51.8 4.88 50.2 50.2 5.45 48.5 48.5 6.10 45.6 45.6 6.79 41.6 41.6 7.55 72 67.6 34.3 4.68 65.3 33.7 5.21 62.4 32.9 5.79 58.6 31.6 6.42 55.0 30.5 7.13 50.9 29.2 7.92 67 63.6 45.4 4.61 60.7 44.5 5.12 57.6 43.5 5.68 54.3 42.4 6.32 50.7 41.2 7.02 44A 38.8 7.74 2000 63ti 60.3 45,2 4.56 57.2 43.9 5.06 53.8 42.5 5.60 50.5 41.1 6.23 45.1 38.9 6.86 39.9 36.7 7.57 62 59.7 57.0 4.55 56.7 55.4 5.05 53.4 53.4 5.60 51.2 51.2 6.24 47.2 47.2 6.92 43.1 43.1 7.69 57 57.8 57.8 4.52 55.1 55.1 5.02 53.2 53.2 5.59 51.2 51.2 6.24 47.4 47.4 6.92 43.3 43.3 7.69 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.96 0.99 CK5A/CK5BX 060 1.02 0.99 CC5A/CD5AW 060 1.02 1.02 CK5PA 060 1.02 1.00 CD5PX 060 1.03 1.02 CK5PT 060 1.02 1.00 CE3AA 060 1.00 1.00 CK5PX 060 1.02 0.99 CK313A 060 1.00 1.00 COILS+315(A,J)AV066135 VARIABLE SPEED FURNACE CK5A/CK5BA 060 1.00 1.00 CC5A/CD5AA 060 0.98 0.98 CK5A/CK5BT 060 1.00 1.00 CC5A/CD5AW 060 1.02 0.99 CK5A/CK5BX 060 1.02 1.00 CE3AA 060 1.02 0.98 CK5PA 060 1.00 1.00 CK36A 060 1.02 0.99 CK5PT 060 1.00 1.00 CK5A/CK5BA 060 1.02 0.99 CK5PX 060 1.02 1.00 CK5A/CK5BT 060 1.02 0.99 F(A,B)4(A,B)N(F,B,C) 060 1.00 1.03 CK5A/CK5BX 060 1.02 0.97 FB4(A,B)NB 070 1.02 1.01 CK5PA 060 1.02 0.99 FC4(B,C)N(F,B) 060 1.00 1.04 CK5PT 1 060 1.02 0.99 FC4(B,C)NB 070 1.02 1.02 CK5PX 1 060 1.02 0.97 FE4ANB 006 1.02 0.97 COILS+315(A,J)AV066155 VARIABLE SPEED FURNACE FG3AAA 060 0.98 0.99 CC5A/CD5AA 060 0.98 0.97 FK4(C,D)NB 006 1.02 0.97 CC5A/CD5AW 060 1.00 FV4(A,B)NB 006 1.02 0.97 CD5PX 060 1.03 0.98 FX4(A,B)NB 060 0.98 0.99 CE3AA 060 1.02 0.97 COILS+315(A,J)AV060110 VARIABLE SPEED FURNACE CK3BA 060 1.02 0.98 CC5A/CD5AA 060 0.98 1.00 CK5A/CK5BA 060 1.02 0.98 CD5PX 060 1.03 1.01 CK5A/CK5BT 060 1.02 0.98 CE3AA 060 1.02 1.00 CK5A/CK5BX 060 1.02 0.97 CK3BA 060 1.02 1.00 CK5PA 060 1.02 0.98 CK5A/CK5BA 060 1.02 1.00 CK5PT 060 1.02 0.98 CK5A/CK5BT 1 060 1 1.02 1 1.00 1 CK5PX 060 1.02 0.97 NOTE: When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94.If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity may occur. t Total and sensible capacities are net capacities.Blower motor heat has been subtracted. t Sensible capacities shown are based on 80oF(27°C)entering air at the indoor coil.For sensible capacities at other than 80°F(27°C),deduct 835 Btuh (245 kW)per 1000 CFM(480 L/S)of indoor coil air for each degree below 80*F(27°C),or add 835 Btuh(245 kW)per 1000 CFM(480 L/S)of indoor coil air per degree above 80oF(27°C). '* Total unit kW is total of indoor and outdoor unit kilowatts. tt At TVA rating indoor condition(75*F edb/63°F ewb).All other indoor air temperatures are at 80°F edb. -30- P CONDENSER ONLY RATINGS* SST CONDENSER ENTERING AIR TEMPERATURES°F °F L55 _ 65 75 1 85 95 1 105 115 125 1 TCG 16.0 15.1 14.3 13.4 12.4 11.5 10.5 9.50 30 SDT 67.7 77.4 87.0 96.7 106.4 116.1 125.8 135.2 KW 0.80 0.92 1.06 1.21 1.38 1.56 1.76 1.97 TCG 17.6 16.6 15.7 14.8 13.8 12.8 11.7 10.6 35 SDT 68.7 78.3 88.0 97.6 107.2 116.8 126.4 135.8 KW 0.81 0.92 1.06 1.22 1.39 1.57 1.77 1.99 TCG 19.3 18.3 17.3 16.2 15.2 14.1 13.0 11.8 40 SDT 69.8 79.4 89.0 98.6 108.1 117.7 127.2 136.6 KW 0.82 0.93 1.07 1.23 1.40 1.58 1.79 2.00 TCG 21.1 20.0 18.9 17.8 16.70 15.5 14.3 13.0 45 SDT 71.0 80.6 90.1 99.7 109.2 118.6 128.1 137.4 KW 0.83 0.95 1.08 1.24 1.41 1.59 1.80 2.02 TCG 23.0 21.8 20.6 19.5 18.3 17.0 15.7 14.3 50 SDT 72.3 81.8 91.3 100.8 110.3 119.7 129.1 138.3 KW 0.84 0.96 1.09 1.25 1.42 1.61 1.81 2.03 TCG 25.0 23.8 22.5 21.2 19.9 18.6 17.2 15.7 55 SDT 73.7 83.1 92.6 102.0 111.4 120.8 130.1 139.3 KW 0.85 0.97 1.11 1.26 1.44 1.62 1.83 2.05 1 TCG 21.6 20.0 18.4 16.7 14.8 12.7 10.4 7.8 30 SDT 71.0 80.3 89.5 98.8 107.9 117.0 126.0 134.8 KW 0.96 1.12 1.29 1.48 1.68 1.88 2.08 2.27 TCG 24.0 22.4 20.7 18.9 17.0 14.9 12.6 10.1 35 SDT 72.7 81.9 91.1 100.4 109.6 118.6 127.6 136.4 KW 0.99 1.14 1.32 1.52 1.73 1.94 2.15 2.37 TCG 29.5 24.9 23.2 21.3 19.4 17.3 15.0 12.4 40 SDT 74.5 83.7 92.8 102.0 111.2 120.4 129.3 138.2 KW 1 1.00 1.18 1.36 1.55 1.77 1 2.00 2.23 2.46 TCG 32.3 29.0 26.0 23.9 22.0 19.9 17.6 15.0 45 SDT 76.1 85.3 94.5 103.7 112.9 121.9 130.8 139.6 KW 1.02 1.20 1.39 1.60 1.82 2.05 1 2.29 2.54 TCG 37.7 35.9 30.0 27.2 24.8 22.6 20.3 17.9 50 SDT 77.7 86.7 95.9 105.1 114.2 123.2 132.1 140.8 KW 1.03 1 1.21 1 1.41 1 1.62 1.87 2.12 2.37 2.63 TCG 45.2 38.8 34.9 31.2 28.4 25.9 23.4 20.8 55 SDT 79.1 88.4 97.5 106.5 115.5 124.5 133.3 142.0 KW 1 1.04 1.23 1.43 1.64 1.89 2.14 2.42 2.71 1 1 TCG 26.7 25.3 23.8 22.4 21.0 19.5 18.0 16.4 30 SDT 71.2 80.9 90.6 100. 110. 120. 129. 139. KW 1.41 1.59 1.80 2.04 2.30 2.59 2.91 3.26 TCG 29.3 27.8 26.2 24.6 23.0 21.4 19.8 18.0 35 SDT 72.5 82.1 91.8 101. 111. 121. 130. 140. KW 1.42 1.60 1.81 2.05 2.31 2.60 2.92 3.27 TCG 32.1 30.4 28.7 27.0 25.2 23.5 21.7 19.8 40 SDT 73.9 83.4 93.0 103. 112. 122. 131. 141. KW 1.43 1.62 1.83 2.06 2.32 2.61 2.93 3.28 TCG 35.0 33.2 31.4 29.5 27.6 25.7 23.7 21.6 45 SDT 75.4 84.8 94.4 104. 114. 123. 133. 142. KW 1.45 1.63 1.84 2.08 2.34 2.63 2.94 3.29 TCG 38.2 36.2 34.2 32.2 30.1 28.0 25.9 23.6 50 SDT 77.0 86.4 95.8 105. 115. 124. 134. 143. KW 1.47 1.65 1.86 2.09 2.36 2.65 2.96 3.31 TCG 41.5 39.3 37.2 35.0 32.8 30.5 28.1 25.6 55 SDT 78.7 88.0 97.3 107. 116. 126. 135. 144. KW 1.49 1.67 1.88 2.11 2.38 2.67 2.98 3.33 See notes on page 33. -31- r CONDENSER ONLY RATINGS* Continued SST CONDENSER ENTERING AIR TEMPERATURES°F °F 55 65 75 1 85 95 1 105 115 125 1 TCG 32.6 30.9 29.0 27.1 25.2 23.1 21.0 18.7 30 SDT 74.9 84.4 94.1 104. 113. 122. 132. 141. KW 1.69 1.93 2.19 2.48 2.78 3.10 3.43 3.76 TCG 35.7 33.8 31.9 29.8 27.7 25.6 23.3 20.8 35 SDT 76.4 85.9 95.5 105. 115. 124. 133. 142. KW 1.70 1.94 2.20 2.50 2.81 3.13 3.48 3.83 TCG 39.0 37.0 34.9 32.7 30.5 28.1 25.7 23.0 40 SDT 78.1 87.5 97.1 107. 116, 125. 134. 143. KW 1.71 1.95 2.22 2.51 2.83 3.17 3.52 3.89 TCG 42.5 40.3 38.1 35.8 33.3 30.8 28.2 25.4 45 SDT 79.9 89.3 98.7 108. 118. 127. 136. 145. KW 1.72 1.96 2.23 2.53 2.86 3.20 3.57 3.94 TCG 46.1 43.8 41.4 39.0 36.4 33.7 30.8 27.8 50 SDT 81.8 91.1 100. 110. 119. 128. 137. 146. KW 1.73 1.97 2.25 2.55 2.88 3.24 3.61 3.99 TCG 50.0 47.5 45.0 42.3 39.6 36.6 33.6 303 55 SDT 83.8 93.0 102. 112. 121. 130. 139. 148. KW 1.74 1.99 2.27 2.57 2.91 3.27 3.64 4.04 1• TCG 37.4 35.4 33.3 31.3 29.2 27.1 25.0 22.6 30 SDT 74.9 84.4 94.0 104. 113. 123. 132. 141. KW 1.94 2.21 2.51 2.84 3.22 3.63 4.08 4.58 TCG 41.0 38.8 36.6 34.3 32.1 29.8 27.4 24.8 35 SDT 76.6 86.0 95.5 105. 115. 124. 133. 142. KW 1.98 2.24 2.54 2.88 3.25 3.66 4.11 4.61 TCG 44.7 42.3 39.9 37.5 35.0 32.5 29.9 27.1 40 SDT 78.4 87.7 97.0 107. 116. 125. 134. 144. KW 2.01 2.28 2.58 2.92 3.29 3.70 4.15 4.65 TCG 48.7 46.1 43.6 40.9 38.2 35.5 32.6 29.5 45 SDT 80.3 89.4 98.7 108. 118. 127. 136. 145. KW 2.06 2.32 2.62 2.96 3.34 3.75 4.20 4.69 TCG 52.9 50.2 47.4 44.5 41.6 38.6 35.5 32.1 50 SDT 82.3 91.3 101. 110. 119. 128. 137. 146. KW 2.11 2.37 2.67 3.01 3.39 3.80 4.25 4.73 TCG 57.3 54.4 51.4 48.3 45.2 41.8 38.4 34.7 55 SDT 84.4 93.4 102. 112. 121. 130. 139. 147. KW 2.16 2.43 2.73 3.06 3.44 3.86 4.30 4.78 1. ; TCG 43.2 40.8 38.5 36.2 33.8 31.4 28.9 26.2 30 SDT 77.6 87.0 96.5 106. 115. 125. 134. 143. KW 2.18 2.48 2.82 3.20 3.61 4.08 4.58 5.14 TCG 47.2 44.7 42.2 39.6 37.0 34.4 31.6 28.7 35 SDT 79.4 88.7 98.2 108. 117. 126. 136. 145. KW 2.23 2.53 2.86 3.25 3.66 4.12 4.63 5.19 TCG 51.5 48.8 46.0 43.3 40.4 37.6 34.5 31.3 40 SDT 81.4 90.6 99.9 109. 119. 128. 137. 146. KW 2.28 2.58 2.92 3.30 3.72 4.18 4.68 5.23 TCG 56.0 53.1 50.1 47.1 44.0 40.9 37.6 34.0 45 SDT 83.5 92.6 102. 111. 120. 130. 139. 147. KW 2.34 2.64 2.97 3.35 3.78 4.24 4.74 5.29 TCG 60.8 57.7 54.4 51.2 47.8 44.4 40.8 36.9 50 SDT 85.7 94.7 104. 113. 122. 131. 140. 149. KW 2.40 2.70 3.04 3.42 3.84 4.30 4.80 5.34 TCG 65.8 62.5 59.1 55.5 51.8 48.0 44.2 39.9 55 SDT 88.1 96.9 106. 115. 124. 133. 142. 150. KW 2.47 2.77 3.11 3.49 3.91 4.38 4.87 5.40 See notes on page 33. -32- CONDENSER ONLY RATINGS* Continued SST CONDENSER ENTERING AIR TEMPERATURES°F °F 55 65 75 1 85 1 95 105 115 125 1. 1 TCG 53.4 50.5 47.6 44.7 41.8 38.8 35.7 32.5 30 SDT 77.9 87.5 97.1 107. 116. 126. 135. 144. KW 2.79 3.18 3.61 4.10 4.64 5.23 5.88 6.60 TCG 58.4 55.2 52.1 48.9 45.7 42.5 39.1 35.5 35 SDT 79.8 89.2 98.8 108. 118. 127. 137. 146. KW 2.85 3.24 3.67 4.16 4.71 5.30 5.95 6.66 TCG 63.7 60.3 56.9 53.4 49.9 46.4 42.7 38.7 40 SDT 81.8 91.1 101. 110. 120. 129. 138. 147. KW 2.92 3.30 3.74 4.23 4.78 5.37 6.02 6.72 TCG 69.3 65.6 62.0 58.2 54.4 50.5 46.4 42.1 45 SDT 83.9 93.1 102. 112. 121. 131. 140. 149. KW 2.99 3.37 3.81 4.30 4.85 5.45 6.10 6.80 TCG 75.2 71.3 67.3 63.3 59.1 54.8 50.4 45.6 50 SDT 86.1 95.3 105. 114. 123. 132. 141. 150. KW 3.06 3.45 3.89 4.38 4.93 5.54 6.18 6.88 TCG 81.4 77.2 72.9 68.5 64.0 59.3 54.5 49.2 55 SDT 88.5 97.5 107. 116. 125. 134. 143. 152. KW 3.15 3.54 3.98 4.47 5.02 5.63 6.28 6.96 "ARI listing applies only to systems shown in Ratings and Performance table. kW Outdoor Unit Kilowatts Only SDT-Saturated Temperature Leaving Compressor(°F) SST-Saturated Temperature Entering Compressor(°F) TCG-Gross Cooling Capacity(1000 Btuh). SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01-in.wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature is 125°F(51.7°C). 4. For reliable operation,unit should be level in all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit without additional consideration is: Indoor coil above=20 ft, indoor coil below = 20 ft. Consult Application Guidelines and Service Manual-Air Conditioners and Heat Pumps Using Puron® Refrigerant prior to application if elevations are exceeded. 6. For interconnecting refrigerant tube lengths greater than 50 ft and/or 20 ft vertical differential, consult the Application Guideline and Service Manual-Air Conditioners and Heat Pumps Using Puron®Refrigerant Application Guideline and Service Manual-Air Con- ditioners and Heat Pumps Using Puron®Refrigerant available from equipment distributor. 7. If any refrigerant tubing is buried, provide a 6 in.vertical rise to the valve connections at the unit.Refrigerant tubing lengths up to 36 in.may be buried without further consideration.Do not bury lines over 36 in. 8. Use only copper wire for electric connection at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 9. Do not apply capillary tube indoor coils to these units. 10. Factory-supplied filter drier must be installed.This must be replaced each time the refrigeration system is opened for service. 11. Do not deviate from factory specified TXV's and Liquid Line Solenoids. -33- -34- -35- GUIDE SPECIFICATIONS Air-Cooled, Split-System Air Conditioner 552A 1-1/2 to 5Tons Nominal GENERAL Fans System Description Condenser fan will be direct-drive propeller type,discharging air Outdoor-mounted, air-cooled, split-system air conditioner unit upward. suitable for ground or rooftop installation.Unit consists of a her- Condenser fan motors will be totally enclosed, 1-phase type metic compressor, an air-cooled coil, propeller-type condenser with class B insulation and permanently lubricated bearings. fan, and a control box. Unit will discharge supply air upward as Shafts will be corrosion resistant. shown on contract drawings. Unit will be used in a refrigeration Fan blades will be statically and dynamically balanced. circuit to match up to a packaged fan coil or coil unit. Condenser fan openings will be equipped with PVC-coated Quality Assurance steel wire safety guards. Unit will be rated in accordance with the latest edition of ARI Compressor Standard 210. Compressor will be hermetically sealed. Unit will be certified for capacity and efficiency, and listed in the Compressor will be mounted on rubber vibration isolators. lastest ARI directory. Unit construction will comply with latest edition of ANSI/ Condenser Coil ASHRAE and with NEC. Condenser coil will be air cooled. Unit will be constructed in accordance with UL standards and Coil will be constructed of aluminum fins mechanically bonded will carry the UL label of approval.Unit will have c-UL approval. to copper tubes which are then cleaned, dehydrated, and Unit cabinet will be capable of withstanding Federal Test Method sealed. Standard No. 141 (Method 6061)500-hr salt spray test. Refrigeration Components Air-cooled condenser coils will be leak tested at 150 psig and Refrigeration circuit components will include liquid-line shutoff pressure tested at 450 psig. valve with sweat connections, vapor-line shutoff valve with Unit constructed in IS09001 approved facility. sweat connections, system charge of Puron® (R-410A) Delivery,Storage,and Handling refrigerant,and compressor oil. Unit will be shipped as single package only and is stored and Operating Characteristics handled per unit manufacturer's recommendations. The capacity of the unit will meet or exceed Btuh at a Warranty(for inclusion by specifying engineer) suction temperature of 'F.The power consumption at full U.S.and Canada only. load will not exceed kW. Combination of the unit and the evaporator or fan coil unit will PRODUCTS have a total net cooling capacity of Btuh or greater at Equipment conditions of CFM entering air temperature at the Factory assembled, single piece, air-cooled air conditioner unit. evaporator at °F wet bulb and °F dry bulb,and air Contained within the unit enclosure is all factory wiring, piping, entering the unit at -F. controls, compressor, refrigerant charge Puron®(R-410A), and The system will have a SEER of Btuh/watt or greater at special features required prior to field start-up. DOE conditions. Refrigerant Electrical Requirements Refrigerant will be Puron (R-410A) HFC Refrigerant with zero Nominal unit electrical characteristics will be v, single ozone depletion potential.R-410A is approved under the EPA's phase, 60 hz.The unit will be capable of satisfactory operation Significant New Alternatives Program (SNAP). within voltage limits of v to V. Unit Cabinet Unit electrical power will be single point connection. Unit cabinet will be constructed of galvanized steel, bonderized, Control circuit will be 24v. and coated with a powder coat paint. Special Features Fans Refer to section of this literature identifying accessories and Condenser fan will be direct-drive propeller type,discharging air descriptions for specific features and available enhancements. upward. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS 1 ® Cancels: PDS 552A.18.4 Heating&Cooling Systems New: PDS 552A.18.5 0 2004 Bryant Heating&Cooling Systems,7310 W.Morris St. Indpls,IN 46231 —36— PRINTED IN U.S.A. Catalog No. 5255-208 7-04