HomeMy WebLinkAbout17831 59th Ave Ne_BLD399_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17831 59th Ave Permit#:399 Parcel#:31052200403600 Valuation:60000.00 OWNER APPLICANT CONTRACTOR Name:ARLINGTON ADVANCED Name:Green Fire Production Name:Color&Arches Corporation LLC MANUFACTURING PARK Address:3316 FUHRMAN AVE E STE 200 Address:1783 1 59th Ave#7 Address:7625 172nd St SE City,State Zip:SEATTLE,WA 98102 City,State Zip:Arlington,WA 98223 City,State Zip:Snohomish,WA 98296 Phone: Phone:530-693-5038 Phone:425-773-8949 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Color&Arches Corporation LLC Name: Address:7625 172nd St SE Address: City,State,Zip:Snohomish,WA 98296 City,State,Zip: Phone:425-773-8949 Phone: LIC#:COLORAC906R7 EXP: 3/19/2015 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27, THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City r ngton rust be reported on your sales tax return form and coded Citv of Arlington#3101. L r /I Irg CrDAI Signature Print Name Date Relras- By Date CONDITIONS THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/13/2014 Mechanical Fee(Enter Fixture Fee) $500 00 6/13/2014 Mechanical Permit Base Fee $25.00 6/13/2014 Mechanical Plan Review Fee $200,00 Total Due: $725.00 Total Payment: $0.00 Balance Due: S725.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon • COMMERCIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: * New Installation 0 Replacement 0 Alteration Project Valuation: 60,000 Parcel ID# ? Project Address: 17831 59th ave NE Arlington WA 98223 # 7 Project AC install Description: Owner: Brent Address: 17831 59th ave NE City: Arlington State: Wq ZIP: 98223 Contact Person: Keith Holton Phone: 5306935038 Cell Phone: 5306935038 Fax Number: E-mail: bbrec@ymail.com Address: 17831 59th ave NE # 7 City: Arlington State: Wq ZIP: gg223 Contractor Information Contractor: Color and Arches Phone: 425.773.8949 Address: 7625 172nd st se City: Snohomish State: Wq ZIP: 98296 License Number: COLORAC906R7 Expiration: 3/19/2015 Please indicate type of number of appliances: CONDENSING ® AC (VRF) GAS PIPING UNIT OUTLET HEAT PUMP FURNACE UNIT HEATER (multi-split) HEAT PUMP BOILER PAINT (mini-split) BOOTH Furnace CHILLER DRYER HEAT REJECTION COOLER TYPE I EQUIPMENT HOOD AC (air cooled) ® TYPE II AST HOOD AC (water cooled) VENTILATION UST SYSTEM AC (evaporator) PACKAGE OTHER UNIT Please Attach Plans and Supporting Documents (PDF Only) Gmail - Roof mount details AC condenser..pdf STAFF USE ONLY: Permit Number: Accepted Receipt # By: Date Received: Amount Received: By submission of this form, I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington. Permit#: 399 Permit Date: 06/12/14 Permit Type: COMMERCIAL MECHANICAL Project Name: Green Fire Production Applicant Name: Green Fire Production Applicant Address: 17831 59th Ave#7 Applicant, City, State, Zip: Arlington,WA 98223 Contact: Keith Holton Phone: 530-693-5038 Email: bbrec@ymail.com Scope of Work: A/C Installation Valuation: 60000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/18/2014 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31052200403600 17831 59TH AVE NE ADVANCED 637 Warehousing& MANUFACTURING Storage Services PARK Contractors Contractor Primary Contact Phone Address Contractor Type License License# Color&Arches Vernon Lovelace 425-773-8949 7625 172nd St SE CONSTRUCTION COLORAC906R7 Corporation LLC CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 06/12/2014 COMMERCIAL Ok to issue z.Christopher Young MECHANICAL Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $500.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $200.00 Total $725.00 Attached Letters Date Letter Description 06/13/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/18/2014 Keith Holton Cash $725.00 Outstanding Balance $0.00 Uploaded Files Date File Name 06/12/2014 Roof mount details AC condenser..pdf 06/12/2014 Commercial Mechanical Permit Applicationpdf.pdf Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM C.1 I I Vernon Kelly Lovelace <vernonlovelace81@gmail.com> Roof mount details AC condenser. A mPRRnnPR William Inderbitzen <willinderbitzen@gmail.com> Tue, Jun 10, 2014 at 10:36 AM To: vernon love lace81 @gmail.com Condensing unit roof mount bases will be constructed from pressure treated lumber and assembled with appropriate corrosion resistant fasteners and bracing hardware to maintain a secure and level foundation for the life of the equipment. Support structure will be fastened to underlying steel supports and all roof penetrations will be sealed. Condensing units will be mounted 20' or more from roof edge. 1) 3 Primary supports will be cut from pressure treated 6x8 stock to accommodate a 1 in12 roof pitch, span the steel support structure and provide weight distribution. 2) 3 cross members will be cut from 4x4" pressure treated stock to incorporate primary supports, elevate equipment and provide appropriate unit mounting locations. 3) Hot Dip galvanized or stainless fasteners will be used and cuts that expose lumber interior will be treated with copper napthenate wood preservative. 4) Roof penetration for copper refrigerant lines and will be sealed with a flexible insulating flashing and caulking formulated to adhere to galvanized steel. 5) Refrigerant lines and control wires will will be properly insulated, protected from UV damage and mounted on elevated blocks. WIWI- NO roof_viewjoists.jpg 4i; 121 K Vernonlovelace <vernonlovelace81 @gmail.com> Tue, Jun 10, 2014 at 12:52 PM To: "cyoung@arlingtonwa.gov" <cyoung@arlingtonwa.gov> Will this work for the AC instalion on the roof? Sent from my iPhone Begin forwarded message: From: William Inderbitzen <willinderbitzen@gmail.com> Date: June 10, 2014 at 10:36:49 AM PDT To: vernonlovelace8l@gmail.com https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 1 of 7 Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM JUUjCIi I. F%VVI 111VU11L UC1Q112! /1V 1.V 11UC11AC1. [Quoted text hidden] Christopher Young <cyoung@arlingtonwa.gov> Tue, Jun 10, 2014 at 12:57 PM To: Vernonlovelace <vernonlovelace81 @gmail.com> How much does the unit weigh? How close to the roof edge will it be? Is there roof access? Christopher Young Building Official City of Arlington 360-403-3432 cyoung @ arlingtonwa.gov ® �ja https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 2 of 7 Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM "The importance of a strong building code is most evident after a disaster." From: Vernonlovelace [mailto:vernonlovelace8l@gmail.com] Sent: Tuesday, June 10, 2014 12:53 PM To: Christopher Young Subject: Fwd: Roof mount details AC condenser. [Quoted text hidden] Vernonlovelace <vernonlovelace81 @gmail.com> Tue, Jun 10, 2014 at 1:16 PM To: Christopher Young <cyoung@arlingtonwa.gov> I will get that info to you soon. Also can we pull the permit ourselves. Or do we need a mechanical license to pull the Hvac permit. Sent from my Phone On Jun 10, 2014, at 12:57 PM, Christopher Young <cyoung@arlingtonwa.gov> wrote: How much does the unit weigh? How close to the roof edge will it be? Is there roof access? Christopher Young Building Official City of Arlington 360-403-3432 cyoung@?arlingtonwa.gov <image001.png><image002.png><image003.png> "The importance of a strong building code is most evident after a disaster." From: Vernonlovelace [mailto:vernonlovelace8l@gmail.com] Sent: Tuesday, June 10, 2014 12:53 PM To: Christopher Young Subject: Fwd: Roof mount details AC condenser. https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 3 of 7 Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM Will this work for the AC instalion on the roof? Sent from my iPhone Begin forwarded message: From: William Inderbitzen <willinderbitzen@gmail.com> Date: June 10, 2014 at 10:36:49 AM PDT To: vernon love lace81 @gmail.com Subject: Roof mount details AC condenser. Condensing unit roof mount bases will be constructed from pressure treated lumber and assembled with appropriate corrosion resistant fasteners and bracing hardware to maintain a secure and level foundation for the life of the equipment. Support structure will be fastened to underlying steel supports and all roof penetrations will be sealed. Condensing units will be mounted 20' or more from roof edge. 1) 3 Primary supports will be cut from pressure treated 6x8 stock to accommodate a 1 in12 roof pitch, span the steel support structure and provide weight distribution. 2) 3 cross members will be cut from 4x4" pressure treated stock to incorporate primary supports, elevate equipment and provide appropriate unit mounting locations. 3) Hot Dip galvanized or stainless fasteners will be used and cuts that expose lumber interior will be treated with copper napthenate wood preservative. 4) Roof penetration for copper refrigerant lines and will be sealed with a flexible insulating flashing and caulking formulated to adhere to galvanized steel. 5) Refrigerant lines and control wires will will be properly insulated, protected from UV damage and mounted on elevated blocks. <image004.jpg> Christopher Young <cyoung@arlingtonwa.gov> Tue, Jun 10, 2014 at 1:27 PM To: Vernonlovelace <vernonlovelace81 @gmail.com> Just a contractor license is needed Christopher Young Building Official City of Arlington 360-403-3432 cyoungC arlingtonwa.gov https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 4 of 7 Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM ® J0 "The importance of a strong building code is most evident after a disaster." From: Vernonlovelace [mailto:vernonlovelace8l@gmail.com] Sent: Tuesday, June 10, 2014 1:17 PM To: Christopher Young Subject: Re: Roof mount details AC condenser. [Quoted text hidden] William Inderbitzen <willinderbitzen@gmail.com> Tue, Jun 10, 2014 at 1:39 PM To: vernonlovelace8l@gmail.com Each condensing unit weighs 298lbs They will be a minimum of 24' from the edge of the roof The roof is accessible by an exterior mounted service ladder on the east side of the building. [Quoted text hidden] Vernonlovelace <vernonlovelace81 @gmail.com> Tue, Jun 10, 2014 at 3:54 PM To: Christopher Young <cyoung@arlingtonwa.gov> Here are those answers you had. Sent from my iPhone Begin forwarded message: From: William Inderbitzen <willinderbitzen@gmail.com> Date: June 10, 2014 at 1:39:48 PM PDT To: vernonlovelace8l@gmail.com Subject: Re: Roof mount details AC condenser. [Quoted text hidden] Christopher Young <cyoung@arlingtonwa.gov> Wed, Jun 11, 2014 at 7:13 AM To: Vernonlovelace <vernonlovelace81 @gmail.com> Last question — how many condensers are we talking and what is the spacing? Christopher Young https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 5 of 7 Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM Building Official City of Arlington 360-403-3432 cyoung @ arlingtonwa.gov ® �ia "The importance of a strong building code is most evident after a disaster." From: Vernonlovelace [mailto:vernonlovelace8l@gmail.com] Sent: Tuesday, June 10, 2014 3:54 PM To: Christopher Young Subject: Fwd: Roof mount details AC condenser. [Quoted text hidden] Vernonlovelace <vernonlovelace81 @gmail.com> Wed, Jun 11, 2014 at 7:30 AM To: Christopher Young <cyoung@arlingtonwa.gov> There is 8 of them and they are spaced over main truss supports about 24' apart. Sent from my Phone On Jun 11, 2014, at 7:13 AM, Christopher Young <cyoung@arlingtonwa.gov> wrote: Last question— how many condensers are we talking and what is the spacing? Christopher Young Building Official City of Arlington 360-403-3432 cyoung@?arfingtonwa.gov <image001.png><image002.png><image003.png> https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 6 of 7 Gmail-Roof mount details AC condenser. 6/12/14 8:09 AM "The importance of a strong building code is most evident after a disaster." From: Vernonlovelace [mailto:vernonlovelace8l@gmail.com] Sent: Tuesday, June 10, 2014 3:54 PM To: Christopher Young Subject: Fwd: Roof mount details AC condenser. Here are those answers you had. Sent from my iPhone Begin forwarded message: From: William Inderbitzen <willinderbitzen@gmail.com> Date: June 10, 2014 at 1:39:48 PM PDT To: vernon love lace81 @gmail.com Subject: Re: Roof mount details AC condenser. Each condensing unit weighs 298lbs They will be a minimum of 24'from the edge of the roof The roof is accessible by an exterior mounted service ladder on the east side of the building. On Jun 10, 2014 10:36 AM, "William Inderbitzen" <willinderbitzen@gmail.com> wrote: Condensing unit roof mount bases will be constructed from pressure treated lumber and assembled with appropriate corrosion resistant fasteners and bracing hardware to maintain a secure and level foundation for the life of the equipment. Support structure will be fastened to underlying steel supports and all roof penetrations will be sealed. Condensing units will be mounted 20' or more from roof edge. 1) 3 Primary supports will be cut from pressure treated 6x8 stock to accommodate a 1 in12 roof pitch, span the steel support structure and provide weight distribution. 2) 3 cross members will be cut from 4x4" pressure treated stock to incorporate primary supports, elevate equipment and provide appropriate unit mounting locations. 3) Hot Dip galvanized or stainless fasteners will be used and cuts that expose lumber interior will be treated with copper napthenate wood preservative. 4) Roof penetration for copper refrigerant lines and will be sealed with a flexible insulating flashing and caulking formulated to adhere to galvanized steel. 5) Refrigerant lines and control wires will will be properly insulated, protected from UV damage and mounted on elevated blocks. https://mail.google.com/mail/u/0/?ui=2&ik=ld9a54af4b&view=pt&se...1=14686da970aebc0d&siml=1468b4ed64586dc3&siml=1468b562b5ab74da Page 7 of 7