Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17909-A 34TH DR NE_045853_2026
I T'f C3 F= A F?L- 11V G T C31,1 CC3IVST RUST- I C3ii1 PEFZM I T PERM I -F 1VC3 _ _ AZO4-5853 Owner: DB JOHNSON CONSTRUCTION 1801 GROVE ST MARYSVILLE 98270 Value of Work: $191, 000. 00 Tay: ID: 010035-000-006-00 Phone: 360-659-1579 Describe Work: NEW CONSTRUCTION DUPLEX Proposed Use: SFR-2 Legal Description: CAROLA ADDITION LOT 6 Job Address: 17909 34TH PL HE Contractor's Name Type Address License* DB jOHNSGN CONSTRUCTION GEN 1801 GROVE ST DBJOHCI044BA G 8, S HEATING MEC: 5�06 E MAIN ST GSHEAC1147JD 1 MARYSVILLE PLUMBING INC. PLB 3318 SR 530 NE. MARYSPI101JE P E R M I T F E E S Equipment and Fixtures Number Fee Total Charge - ------------------------ - - r'LUMBING FIXTURES 24 S10. 00 S240, 00 FURNA%EiUNIT HEATER 2 $15. 00 530. 00 VENTILATION FANS 8 $7. 00 $56. 00 DRYER $i l. oo $22` 00 ! WATER HEATER ? $i5. 00 $30. 00 ! GAS PIPING 1-4 OUTLETS 2 $6. 00 $i2.. 00 l! S U H T O T A L. . . . . . $390.00 ! 1 ! TOTALS Fee Permit Fee $1, 661. 45 Equipment $-150. 00 Fixture $240. 00 Lakewood School Mit $0. c10 Mech Permit $24. 00 Plan Fee $i, 079. 94 l �1 Plumb Permit $25. 00 State fee $4. 50 Traffic Mitigation $1, T038. 00 SIGNATURE: TOTAL FEE. . . . . . . . . . . . . . . . . $4, 222. 89 I ' EB CERTIFY" THAT I HAVE READ A: -XAMINED THIS APPLICATION[ AND PAYMENTS. . . . . . . . . . . . . . . . . . $1, 043. 67 K THE SAME TO BE TRUE AND COR- R=. ALL PROVISIONIS OF LAWS AHD TOTAL DUE. . . . . . . . . . . . . . . . . S3, 179. 22 _ I 'AK'k GOV-RM 11 THIS TYPE OF W - K WIL MP ED WITH WHETHER M MOT. DATE RECEIPT # `� I I SSa3 DING 0FF3 CYIAL CITY OF ARLINGTON CONSTRUCTION PERMIT ®COMBINATION nBUILDING MECHANICAL PLUMBING Ej SIGN PERMIT NO. V V- SF a? OWNER MAIL ADDRESS CITY ZIP PHONE D. B. Johnson Const. 1801 Grove St., #B Marysville 98270 360.659.1579 ARCHITECHT OR DESIGNER MAIL ADDRESS CITY ZIP PHONE Country Roads 930 N. Amy Place Camano Island 98282 360.629.6068 GENERAL CONTRACTOR MAIL ADDRESS CITY ZIP PHONE LICENSE# D. B. Johnson Const. 1801 Grove St., #B Marysville 98270 360.659.1579 DBJOHC1044BA MECHANICAL CONTRACTOR MAIL ADDRESS CITY ZIP PHONE LICENSE# Marysville Plumbing 13318 SR 530 NE Arlington 98223 360.435.5555 WRYSPI101JE PLUMBING CONTRACTOR MAIL ADDRESS CITY ZIP PHONE LICENSE# G & S Heating 500 E Main St. Monroe 98272 360.794.7306 GSHEACI005C5 CLASS OF WORK ®NEW ADDITION ALTERATION REPAIR DEMOLITION BUILDING RELOCATION VALUATION OF WORK $ ISI, V16.81 DESCRIBE WORK NEW CONSTRUCTION PROPOSED USE OF BUILDING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED HIS APPLICATION DUPLEX AND KNOW THE SAME TO BE TRUE AND CORRECT ALL PROVISIONS OF LEGAL DESCRIPTION OF PROPERTY(SHOWN BELOWORATTACH FOUR COPIES) LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE LOT BLOCK OF Carola Addition COMPLIED WITH WHETHER SPECIFIED HERIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF TAX ID NUMBER CONSTRUCTION. PERMIT EXPIRES 1 YEAR FROM DATE OF ISSUANCE O 1 OD 3S— 9,QNA70ReQE CONTRA R AUTHORIZED AGENT DATE JOB ADDRESS V I-1 of O (OFFICE USE ONLY) PLUMBING MECHANICAL NO. TYPE OF FIXTURE FEE NO. TYPE OF EQUIPMENT FEE WATER CLOSET(TOILET) AIR COND.UNITS-H-P. EA. BATHTUB REFRIGERATION UNITS-H.P. EA. LAVATORY(WASH BASIN) BOILERS-H.P. EA. SHOWER GAS FIRED A.C.UNITS-TONNAGE EA. KITCHEN SINK&DISP c/ FORCED AIR SYSTEMS-B.T.U. MEA DISHWASHER WALL HEATERS-B.T.U. M LAUNDRY TRAY UNIT HEATERS-B.T.U. M CLOTHES WASHER EVAPORATIVE COOLERS WATER HEATER d CLOTHES DRYERS URINAL VENTILATION FAN DRINKING FOUNTAIN RANGE HOOD COMMERCIAL FLOOR DRAIN AIR HANDLING UNIT - CPM VACUUM BREAKERS STOVE ROOF DRAINS-RAINLEADERS METAL FIREPLACE&CHIMNEY SINK(SERVICE-BAR, ETC.) of WATER HEATER GAS PIPING SUBTOTAL SUBTOTAL PERMIT PERMIT TOTALFEE TOTALFEE $ SIDE YARD SETBACK STREET SETBACK REAR YARD SETBACK PLAN CHECK NUMBER PLAN CHEC F 2--L 5 F E o/,OA13.(V- USEZONE LOT AREA VACANT SITE FEES VALUATION FEE ('LA 0 °) f7 ( lo YES [:]NO PLAN CHECKING /U 7 Cj � TYPE OF CONST OCCUPANCY GROUP NO. OF DWELLING 3 r UNITS �J BUILDING �� fe �{�, L{� SIZE OF BLDG NO.OF STORIES MAX.OCC. LOAD PLUMBING 1 � 2— 6-p-°— MECHANICAL FIRE SPRINKLER REQD STA It BLUU.cUUt YES O ENERGY CODE SURCHARGE G U PENALTY U.B.C. COMMENTS 4 SEC 303(a) WATER/SEWER FEES I-tl� 0 ZD04 TOTAL PERMIT VALIDATION �PT WHEN PROPERLY VALIDATED ON THIS SPACE)THIS COA BUILDING D PAID CR# BY BUILDING OFFICIAL DATE CC: ASSESSOR,APPLICANT,TREASURER,BLDG. DEPT. RECORDS COPY Notes: D.B. Johnson Construction, Inc. Site Information: 1. Downspouts to Infiltration Trench (sidewinder 1801 Grove St., Unit B system—75' per lot— 12 sections total-76" per Marysville, WA 98270 Lot 6, of Carols Addition section-see construction drawings& manufacturer (360) 659-1579 specs) Site Address: 17909 34th Place NE 2. Stockpile to be covered within 24 hours. Contact: Stacy Smith Arlington, WA 98223 3. Entire lot to be disturbed. 4. Silt Fence as needed. Tax I.D. # 010035-000-006-00 5. Denuded soils to be straw covered. DBJ Job #: 2300 & 2301 6.Armored Construction Entrance. DBJ Plan #: 1221 Duplex Lot Area: 9,016 S.F. 7. 2 lot trees required—1 credit for Street Tree—1 tree to be planted near rear lot line. 8. Building Height=Approx. 22' 11 9. Lot Coverage: 9,016 X 35% = 3,155 S.F. Scale: 1" — 20' Proposed = 2,128 S.F. 185.82' 0 N O_ ro Patlo �F N Patio J r• C r X X N CO 04 �o \��� Ob r� Garage Garage 10, s 13' Porch Porch 10' Sidewip er—1 sections Sidewinder—2 sections N � y w �_ Driv way N0 0 115.09' Panhandle for Lot 7 —also to serve as RECEIVED Tract D access for lot 6 via. recorded ingress/egress easement AF #200401270101 FEB 0 3 2004 CCp BUILDING DEPT Oq •5%77 INSPECTION REPORT ¢�ZN GrO Permit No.G'L�'YO Y3 Lot #: Q ~ Address: /7 9'09- y /1- Contractor: 60 6 T ems, �O Owner: 13T 41 N Date: S -�" O Ll APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION -24 hour notice required. Inspector: Date:- ' TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove if Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation 0 Other: t'IT INSPECTION REPORT 1;i ?' PermitNo.: ins( S8S3 Lot #: Address: 17 9 09 31{ D 2Contractor: OG T Owner: '� Date: 7- 13- O Y ❑ APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. Inspector: Date: TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in IZ.A Final ❑ Masonry ❑ Drainage ❑ Insulation 0 Other: rr zZ INSPECTION REPORT N G?'O Permit No.: oLt s s s-3 Lot #: Address: i 1°I og 3 g a z Contractor: �SbT Z O Owner: r IN N Date: ?—` -©q ❑ APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ,CORRECTION REQUESTED Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. .ram --5�� - -r�a..� ►u,..` _61 ttIO f3upz9c,s A C'►� ��� �JI�y1VS xJcrf (.4.S a Inspector: Date: TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in 2 X Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: `INSPECTION REPOR1�' p Permit No:_0"fS _ ) Date: Address/Lot No:1� , 1 C( n(j;4 Contractor:AO Owner: Supervisor: -2 Approval ❑ Correction Required ❑ Corrections listed below MUST BE MADE before work can be approved ❑ Please contact inspector ❑ Was not able to perform inspection ❑ Call 360.435.0674 for re-inspection -24-hour notice required a Inspector: Date: 7� TYPE OF INSPECTION REQUIRED TESC STORM DRAIN ROAD LANDSCAPING ❑Slit Fence ❑Pipe ❑Sub-grade ❑Irrigation ❑Check Dam ❑Catch Basin(s) ❑Rock ❑Soil ❑Inlet Protection Cl Manhole(s) J urb&Gutter ❑Fertilizer ❑Temp.Sed ❑Oil Seperator(s) id ewalk ❑Bark ❑Sheeting ❑Down Spouts :1 Approach(s) ❑Plants ❑Straw ❑Trash Rack/Overflow ❑ATB ❑Trees ❑Seeding ❑Restrictor ❑Cl.B Asphalt ❑Root Barriers ❑Final ❑Level Spreader ❑Striping ❑Play Equipment ❑Treatment ❑Signing ❑Final ❑Infiltration ❑Final ,..._.INSPECTION REPORT G1T Y O� Permit No•C)q--5(R,S �-'p Date: �I l Address/Lot N000yy1 la I-7cICC( �Llti,1�111�;E Contractor: ' '0 Owner: PlING Supervisor: VI/I j c•(G(G(- 4-7( � O'Approval ❑ Correction Required ❑ Corrections listed below MUST BE MADE before work can be approved ❑ Please contact inspector ❑ Was not able to perform inspection ❑ Call 360.435.0674 for re-inspection -24-hour notice required Inspector" _ Date: 01- TYPE OF INSPECTION REQUIRED TESC <1TORM DRAIN ROAD LANDSCAPING ❑Slit Fence j i ❑Sub-grade ❑Irrigation ❑Check Dam ❑Catch Basin(s) ❑Rock ❑Soil ❑Inlet Protection ❑Manhole(s) ❑Curb&Gutter ❑Fertilizer ❑Temp.Sed ❑Oil Seperator(s) ❑Sidewalk ❑Bark ❑Sheeting ❑Down Spouts ❑Approach(s) ❑Plants ❑Straw ❑Trash Rack/Overflow ❑ATB ❑Trees ❑Seeding ❑Restrictor ❑Cl.B Asphalt ❑Root Barriers ❑Final ❑Level Spreader ❑Striping ❑Play Equipment ❑Treatment ❑Signing ❑Final 3 Infiltration ❑Final 3 � INSPECTION REPORT Permit No.: �Y 58 S� Lot #.• ZN G (o ¢ti To Q' Address: /7S o 9 3 Li D a— Contractor: O 9� O Owner: �s,�i N C' Date: y — �i APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. Inspector: Date: TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing g Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation 0 Other: INSPECTION REPORT ji r Permit No.: ©Y ��'�3 Lot#: 6 Address: /79 D9 3 Y ✓2Contractor:O Dateer: to-Z—n yy APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. Inspector: Date: ' TYPE OF INSPECTION REQUESTED ❑ Under-floor Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork Omechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage 1�(Insulation ❑ Other: 3'19 INSPECTION REPORT P ¢tiZN G?'o Permit No.: o`i 5953 Lot#: to F Address: / 7 19 09 3 Contractor: t� 4 0 Owner: 9s j N G( Date: 5- 21-a L-1 ❑ APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION OL CORRECTION REQUESTED d'—C—o rrections listed below MUUST�BE MADE beforework can be approved. ❑ Please contact inspector.�t�so► _ % G/ ❑ Was not able to perform inspection.T ❑ (;,ALL 435-0674 FOR RE-INSPECTION - 24 ur notice required. iz InspeC`tor: Date: TYPE OF INSPECTION REQUESTED ❑ Under-floor JK Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork X Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: INSPECTION REPORT cpq,2p* N G?'O Permit No.: ✓c�Lot#: Lo Address: I 1 T79 t6Z1rf1 • �� � Contractor: O Owner: IN iG� Date: ❑ APPROVAL PILPARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. Gam/'✓art !lu'' �!�!'iL�1✓•Z._=-- 1 Inspector: Date: TYPE OF INSPECTION REQUESTED ❑ Under-floor Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: INSPECTION REPORT '/7 `33 7 iio Permit No.: `t&J- 5_ 3 Lot #: 6Address: `716) Contractor:Owner: Date: - APPROVAL ❑ PARTIAL APPROVAL O VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION -24 hour notice required. Inspector: Date: TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation �" Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: -i y5 INSPECTION REPORT ¢tiZN GrO Permit No.: o4' 58 5 3 Lot#: � Address: 1171017 3 Y"''` 19� Z Contractor: �c3� Owner: �`s�iv-4 C'� Date: 5-(0- o g ❑ APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION CORRECTION REQUESTED -� Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. J_ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. AligILr !J4 NOi i'Q—_1 (-=?VCG .5A-Z--C. 5�o i,� e►v C.�,,�:r-t-�2�N�� �,2. Lbw' <!-r:�� Fxc.�� E�"c,7#7t ;I�iiy�JS�'yC 63cTi'�—vim 1,yj*71,3 jai rc PCAJLJW+'Tt P457_ Fu�sr- Inspector: " Date: - Lf TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation OShear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: INSPECTION REPORT 4tiLN Gl.O Permit No.: o L-C:TBj-lot #: Q' Address: 1 - 3 Ll -7L� � � Contractor: Owner:�IN�' Date: -© X ❑ APPROVAL --PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION -24 hour notice required. o eoy�- w T-1 Inspector: Date: -a TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove / ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: / Z31 INSPECTION REPORT ¢ti1N GrO Permit No.: oy G,?53 Lot#: Address: /7 9 0; 3 y '`"` D Contractor: !)C.cT O Owner: IN G� Date: `f-- 2_3 - c>y APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. tP A1Y)s�t�v Inspector: Date: TYPE OF INSPECTION REQUESTED Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: IN PECTION REPORT G1Z Y �� Permit No:0¢-SSc S Date: f3 I Q S Address/Lot No: CY-7VD11 a Qx N E Contractor: tIN G.SOZ Owner: Supervisor: 31o(D-lc Ce) - q-7 t 3 Approval ❑ Correction Required ❑ Corrections listed below MUST BE MADE before work can be approved ❑ Please contact inspector ❑ Was not able to perform inspection ❑ Call 360.435.0674 for re-inspection -24-hour notice required Inspector: Date: TYPE OF INSPECTION REQUIRED TESC STORM DRAIN ROAD LANDSCAPING ❑Slit Fence ❑Sub-grade ❑Irrigation ❑Check Dam ❑Catch Basin(s) ❑Rock ❑Soil ❑Inlet Protection ❑Manhole(s) ❑Curb&Gutter ❑Fertilizer ❑Temp.Sed ❑Oil Seperator(s) ❑Sidewalk ❑Bark ❑Sheeting ❑Down Spouts ❑Approach(s) ❑Plants ❑Straw ❑Trash Rack/Overflow ❑ATB ❑Trees ❑Seeding ❑Restrictor ❑Cl.B Asphalt ❑Root Barriers ❑Final ❑Level Spreader ❑Striping ❑Play Equipment ❑Treatment ❑Signing ❑Final Infiltration ❑Final y Y1 Q� INSPECTION REPORT 1;4 p PermitNo.: oq 5853 Lot#:Address: t-7 90 3 Lf w�Contractor:Owner: EC Date: 3- 2- ©Lf ❑ APPROVAL A PARTIAL APPROVAL ❑ VIOLATION 0 CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION -24 hour notice required. Coe Inspector: -y Date: ® TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry Drainage ❑ Insulation ❑ Other: �z Ufa INSPECTION REPORT ¢ti1N G rO Permit No.: o-f 5s 5 3 Lot#: Q Address: I') 109 3 `l � Z Contractor: D O Owner: jNO� Date: t�APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. j N a 9_akSY� Inspector: es Date: 2_2-5_tD� TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation X Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation 0 Other: INSPECTION REPORT iiGT Permit No.: oti 58S3 Lot #: Address: l7 J� 3 VContractor: �G Owner: Date: 2-2-3 - 041 APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION - 24 hour notice required. EVa77&a wll046-"w Inspector: Date: y-Z3-ems TYPE OF INSPECTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in ❑ Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: i Q � 7ti r Post-It'Fax Note 7671 DA�IO�_ �,► May 10, 2004 -- riom L- Co. Pit.17, co. Rich Hamlin A � � WZ 926 Psx rt,� O D B. Johnson Construction Z -- 1801 Grove Stroot, writ a Marysville, WA 08270 SLlBJFCT Shoar Transfer, Plan 1221, J.at 6 and Plan 1247, Lot 4, Cougar Point, City of Arlington, JRS # C)4-02A [dear Mr. Str)ne; JRR Engineeiing, iou. (JRR)understands that the sheathing at the front of the above subject buildings was not installed per our typical shear transfer detail. Slrnpson LTP4 plates Should be installed per the enclosed detail. Please advise if you have ally questions or concerns regarding this matter- Sincerely, .IRR cngin�ee-rii-nr, t c Karl Rosman. E.l-T C Concurrence 1-XpIReS/(G 5 2E,es -bra.^afd fC. Ruch. P E. End yh4U2�l..iI doc FROM : JRR ENGINEEPIhA`a, '.r+.c. PI jNF NC!. 25+63; 4506 I1� ;. _0 2004 10:OIPII P. 12747 r A.V 22 -rOP f I-4TO 7 a AIM AfTA14. _ti y �'