Loading...
HomeMy WebLinkAbout18620 59th Dr Ne_BLD5998_2026 FIRE ALARM PERMIT APPLICATION Community&Economic Development 1W City of Arlington• 18204 59th Ave NF,•Arlington,WA 98223 •Phone(360)403-3551 Type of Permit: Tr New Installation ❑ System Modification ❑ Phased Installation Property Address: lb92 V 45 1" Dr Project Valuation: Lot#: Parcel ID No.: Preferred Contact: O Owner Contractor Project Description: Ins�a�l ,� o KS fttdlo fV D106' ( Owner Name: �(11VL�(50i Ae�oSee Ca Home No.: Q f Email Address: AP un Ver5al aero . Urn Cell No.: Mailing Address: S94" Dr NE City: kW!)o State: Zip: 9t22 Contractor Name: ! (C QfId Se-C(X tf�A Office No.: Email Address: �Qtl�e(J` ijI(c •COm Cell No.: yZS- N - 1995 Mailing Address: {� E�QX 31 City: kJ State: Wi'1 Zip:10022 L&I Contractor License Number: ibAF ICz, 0,F (�y2KW Expiration Date: 1 CO 2w SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES AND TWO (2) SETS OF THE FOLLOW: ❑ Complete and Scaled Plans ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,inapplicable NOTE: All Central Station Monitoring must be UL or FM listed. I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. &'04 m\m 19J 0t'sai(Cl rD 1 V 2 Signatur P int Name Date FOR STAFF USE ONLY PERMIT# ACCEPTED BY: DATE STAMP REV12.2020 Page 1 of 2 FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch,Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors,and other such devices. (Each piece is one device) PLAN REVIEW FEES-shall be paid at time of application submittal Less than$5,000.00 = $100.00 (Table 4-10) $5,000.00 &over—based on valuation (Plan Review Fee is 65%of Building Permit Fee Calculation per Table 4-1) REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 IQ11I, Fp4 72) Number of Devices** Device Fee Subtotal 1. to 2 $ 75.00 = $ Vo 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.0 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FRCP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ 00 NEW�.-.. ❑ COMMERCIAL SYSTEM (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500,00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $ PERMIT FEE TOTAL $ 2W o0 PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ REV12.2020 Page 2 of 2 Fire and Security,, LLC. PO BOX 3711 PQARLINGTON,WA 98223 Hwi"ltlnlnl MITII I I III Ill LIC.# BHFIRHF842KW PH: 425-244-1445 5/16/2024 Universal Aerospace Co 18620 591h Dr Ne Arlington, WA 98223 Scope Of Work: B&H Fire and Security proposes to replace old, decommissioned ADT communicator with new AES Radio for fire alarm monitoring. Construction Manager Jeff Brossard aes-corp.com of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights i • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options �L • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies(MCT)feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D _ Subscriber ----'--------- / 1 1 C B)Fire / / ` Subscriber / _ AES-Network Management System B ———————————— Primary AES-Mul[iNe[Receiver � I A)Alarm Panel Secondary AES-MUIt Net Receiver / � I 0 :C Alarm Automation p ———-_— --- C)IPLinks Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel&AES Subscriber Multi-path AES-IntelliNet@ Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units.A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire InteffiNet 2.0 Fire Subscribers 2.0 PREMIUM (UL& ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy . • - 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication 4+4:4 reverse polarity input and USB access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-IntelliPro for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem IIla2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop, or PC ANTENNA Receiving Centres and Systems 2.5dB tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+ charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60oC) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. f in 0 v o www.aes-corp.com AES Corporation 1 285 Ne • Peabody, MA 01960 United States O Copyright 2018AES • •• • • S are registered trademarks of AES Corporation aes-corp.com ,rsi:cuRrry ES- CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble 7 a backlit LCD display, and Menu/Silence button CITY OF ARLINGTON • Includes robust Multiple Communication Technologies(MCT)feature BUILDING DEPARTMENT • Emulates virtual keypad APPROVE® • Improves functionality with an adaptive Graphic User Interface (GUI)for progra ,iming via smartphones, tablets and PCs DATE Z BY • Plus many more... NO CHANGES AUTHORIZED UNLESS APPROVED BY THE Key Benefits BUILDING INSPECTOR • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to mec ?t'EICEIVED and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network.The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) IineS. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status.The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—wiLhouL file Heed for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D Subscriber - tat B ---__ C �> t „ B)Fire 1 /. Subscriber �' t AESNewarkManagemen[Sysrem it g -- - ----- ----- D i -- _ — -i ` irlmsrY AESMuI[INe[Receiver r A)Alarm Panel secooJAry AESMuhlNrr Re<a B !B Alarm Automation A - Q IP Links Customer Location Mesh Radio Technology Central Monitoring Station Alarm Panel&AES Subscriber Multi-Path AES-IntelliNet®Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units.A FACP Power Supply Adapter is required for certain configurations when using flexible power options.The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources r How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL& ULC Listed) 7707P-88-M IntelliNet2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised)with Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber,4x4 Zone (4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with Firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy • b- 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 Full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity, 4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication 4+4:4 reverse polarity input and USE; access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-IntelliPro for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem Illa2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone, tablet, Equipment for Fire Signal laptop, or PC ANTENNA Receiving Centres and Systems 2.5 dB tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/ charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60°C) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-conclensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. f in 0 v o AES Corporation 1 285 Newbury Street I Peabody, MA 01960 United States Corporation CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 18620 59TH DR NE Permit#: 5998 Parcel#:00448200002401 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Installation of AES radio for monitoring Valuation:750.00 OWNER APPLICANT CONTRACTOR PETTIT INTERNATIONAL LLC B&H Fire and Security B&H FIRE AND SECURITY LLC 18640 59TH DR NE PO Box 3711 PO BOX 3711 ARLINGTON,WA 98223 Arlington,WA 98223 ARLINGTON,WA 98223 360-322-7634 425-244-1445 1.10 603 612 112 EXP:04/30/2025 UC:BHFHt1HF842KW EXP:05/16/2026 PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION ' PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: 0 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL 4.�,N, The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 05/20/2024 Ap6icant Signature Date Building Official Date S Adhere to approved plans. Call for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. FEES Date Description Fee Amount 05/20/2024 Web Only-Fire System Plan Re\iew $200.00 05/20/2024 Credit Card Service $6.00 05/20/2024 Processing/Technology $25.00 05/20/2024 FACP/Transmitter-Replace $125.00 05/20/2024 Fire Alarm System Permit $75.00 Total Due: $431.00 Total Payment: $431.00 Balance Due: $0.00 Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested, and whether,you prefer morning or afternoon INSPECTION INFORMATION I PasstFail Permit#: 5998 Permit Date: 05/17/24 Permit Type: FIRE ALARM Project Name: Universal Aerospace Co Applicant Name: B &H Fire and Security Applicant Address: PO Box 3711 Applicant, City, State, Zip: Arlington,WA 98223 Contact: Hailey Brossard Phone: 360-322-7634 Email: hailey@bnhfire.com Scope of Work: Installation of AES radio for monitoring Valuation: 750.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/20/2024 Permit Expires: 11/20/2024 Form Permit Type: FIRE ALARM Status: COMPLETE Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning PETTIT 00448200002401 18620 59TH DR NE INTERNATIONAL Fly Airports& Flying Fields LLC Fly Contractors Contractor Primary Contact Phone Address Contractor Type License License# B&H FIRE AND JEFF BROSSARD 425-244-1445 PO BOX 3711 ELECTRICAL COA 603 612 112 SECURITY LLC CONTRACTOR B&H FIRE AND JEFF BROSSARD 425-244-1445 PO BOX 3711 ELECTRICAL LABOR&BHFIRHF842KW SECURITY LLC CONTRACTOR INDUSTRIES Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FA00.FIRE ALARM Approved.Checked signals 05/30/2024 FINAL and confirmed dispatch to 06/03/2024 06/03/2024 FIRE Approved correct#DAQ 5.0 Plan Reviews Date Review Type Description Assigned To Review Status 05/20/2024 FIRE ALARM BUILDING Approved Fees Fee Description Notes Amount Enter 1 if permit is for:fire alarm,or fire Web Only-Fire System Plan Review sprinkler $200.00 Credit Card Service $6.00 Processing/Technology $25.00 FACP/Transmitter-Replace $125.00 Fire Alarm System Permit NFPA 72- 105.7.3 $75.00 Credit Card Service $6.75 Total $437.75 Attached Letters Date Letter Description 05/20/2024 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/17/2024 XBP Con£ $200.00 200043985 05/17/2024 200043985 Ameresia Lawlis $6.00 05/20/2024 XBP Con£ $225.00 200359500 05/20/2024 Jeff Brossard 2003 59500 $6.75 Outstanding Balance $0.00 Uploaded Files Date File Name 05/20/2024 20744370-20240520 BLD5998 IssuedPermit.pdf 05/17/2024 20723768-20240516 BLD5998 App.pdf 05/17/2024 20723767-20240516 BLD5998 Spec.pdf 05/17/2024 20723766-20240516 BLD5998 SOW.pdf