Loading...
HomeMy WebLinkAbout17322 84th Ave Ne_BLD6061_2026 i RESIDENTIAL PHOTOVOLTAIC SOLAR PANEL ` Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 The City of Arlington requires a building permit to install Photovoltaic (PV) Solar Panel(s) for residential and commercial uses.This policy governs Residential uses only. Other permits may be required per Washington State Labor and Industries or Utility Providers. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING: REQUIRED DOCUMENTS City of Arlington Solar Panel Application Roof Plan and Construction Documents Manufacturer's installation specifications Engineering, (if required) Type of Permit: [D New Installation ❑ Addition ❑ Replacement Property Address: 17322 84th Ave NE,Arlington, Washington, 98223 project Valuation: $5683.86 Lot#: 20 Parcel ID No.: 01089200002000 Subdivision: Eagle Heights Project Scope of Work: 6.3 kW PV Solar Panel Installation on Roof Primary Contact: ❑ Owner 21 Contractor Owner Name: eileen beers Home No.: Email Address: esalsa99@yahoo.com Cell No.: 4256980563 Mailing Address: 17322 84th Ave NE City: Arlington State: WA Zip: 98223 Contractor Name: BRS Field Ops, LLC Office No.: Email Address: permitting.department@blueravensolar.com Cell No.: 385-482-0045 Mailing Address: 1403 N Research Way City: Orem State: UT Zip: 84097 L&I Contractor License Number: BRSFIF0820N3 Expiration Date: 08/23/24 Existing Roof Structure: Existing Roof Material: Comp Shingle Building Square Footage: 2640 Number of Stories: 1 INSPECTION REQUIREMENTS Roof mount panels require two(2) inspections minimum 1. The first inspection is for the roof mount racking hardware to verify compliance and attachment. (You may schedule this inspection for the day the panels are being installed. You may begin mounting panels over the racking prior to inspection but there must be enough racking exposed for the inspector to verify compliance.) 2. The final inspection shall be scheduled when the project is complete and after Labor and Industries has approved the electrical. I hereby certify that 1 am the ❑ Owner S Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington. Permitting Coordinator 4(hr rhmpsoz� Amber Thompson 07 / 01 / 2024 Signature Print Name Date SAVE PRINT Dom 11 S Dom Ls Structural Engineering, LLC -S T R U C T U R A L P.O .Box 560 Broom field, CO 80038 N G 1 N F F. R T N G 1, 1. C, 530-864-7055 projects@dom Lsstruc.com July 1,2024 To: Blue Raven Solar 1403 North Research Way,Building Orem,UT.84097 Subject: Certification Letter Beers Residence 17322 84th Ave NE Arlington,WA 98223 To Whom It M ay Concern, A jobsite observation of the condition of the existing fram hg system was perform ai by an audit team of Blue Raven Solar as a request from Dom u;Structural Engineering.All review is based on these observations and the design criteria listed below and only deem ad valid if provided inform aion is true and accurate. On the above referenced project,the roof structural fram hg has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elem arts.The observed roof fram hg is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structure of(M Pl)consists of com position shingle on roof plywood that is supported by pre-m aiufactured trusses that are spaced at @ 24"o.c..The top chords,sloped at 27 degrees,are 2x4 sections,the bottom chords are 2x4 sections and the web m en bers are 2x4 sections.The truss m en bers are connected by steel gusset plates.The m ac unsupported projected horizontal top chord span is approxim ately 6'-4". The existing roof fram hg system of(M Pl)is judged to be adequate to withstand the loading im posed by the installation of the solar panels.No reinforcem art is necessary. The spacing of the solar standoffs should be kept at 72"o.c.for landscape and 48"o.c.for portrait orientation,with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly lim ted to an evaluation of the fastener attachm art,underlying fram hg and supporting structure only.The attachm arts to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading.All panels,racking and hardware shall be installed per m aiufacturer specifications and within specified design lim Cations.All waterproofing shall be provided by the m aiufacturer. Dom us Structural Engineering assum a no responsibility for m 6use or im proper installation of the solar PV panels or racking. Design Criteria: • Applicable Codes=2021 IBC/IRC,ASCE 7-16 LL • Roof Dead Load=7 psf(M Pl) • Roof Live Load=20 psf • Wind Speed=115 m ph(Vult),Exposure C • Roof Snow Load=25 psf • Attachm art:1-5/16 dia.lag screw with 2.5 inch m in.em bedm art depth,at spacing shown above. �� 46056 �FCl1L� w4 Please contact m ewith any further questions or concerns regarding this project. s+ SIDNAL EEC' Sincerely, Digitally signed by John A. Calvert John Calvert,P.E. Date:2024.07.01 07:48:33 Project Engineer -06'00' Beers Arlington WA 1 Dom u S Dom us Structural Engineering, LLC STRUCTURAL P.O .Box 560 Broom field, CO 80038 N G T N F F. R T N G 1. 1. C: 530-864-7055 projects@dom usstruc.com G cavity Loading Roof Snow Load Calculations p9=Ground Snow Load= 25.0 psf pf=0.7 Ce Ct I py (ASCE7-Eq 7-1) Ce=Exposure Factor= 1 ( ASCE7-Table 7-2) Cf=Thermal Factor= 1 ( ASCE7-Table 7-3) 1=Importance Factor= 1 pf=Flat Roof Snow Load= 25.0 psf PS=CSpf (ASCE7-Eq 7-2) Cs=Slope Factor= 1.00 ps=Sloped Roof Snow Load= 25.0 psf PV Dead Load=3 psf(Per Blue Raven Solar) DL Adjusted to 27 Degree Slope 3.37 psf PV System W dght W tight of PV System(Per Blue Raven Solar) 3.0 psf X Standoff Spacing= 4.00 ft Y Standoff Spacing= 6.08 ft Standoff Tributary Area= 24.33 sft Point Loads of Standoffs 73 lb Note:PV standoffs are staggered to ensure proper distribution of loading Roof Live Load=20 psf Note:Roof live load is removed in area's covered by PV array. Roof Dead Load(MP1) Composition Shingle 4.00 psf Roof Plywood 2.00 psf 2x4 Top Chords @ 24"o.c. 0.73 psf Vaulted Ceiling 0.00 psf (Ceiling Not Vaulted) Miscellaneous 0.27 psf Total Roof DL(MP1) 7.0 psf DL Adjusted to 27 Degree Slope 7.9 psf Beers Arlington WA 2 Do M u S Dom us Structural Engineering, LLC TRUCTURAL ld, CO8038 LL� Broom field, CO 80038 �L N G I N R E R I N c, L L C 530-864-7055 projects@dom usstruc.com Wind Calculations Per ASCE 7-16 Corn ponents and Cladding Input Variables W hd Speed 115 mph Exposure Category C Roof Shape Gable Roof Roof Slope 27 degrees Mean Roof Height 20 ft Effective W hd Area 21.3 ft Ground Elevation 0 ft Design W hd Pressure Calculations qh=0.00256*Kz*Kzt*Kd*Ke*VA (Eq.26.10-1) Kz(Exposure Coefficient)=0.90 ( Table 30.3-1) Kzt(Topographic Factor)= 1.00 ( Fig.26.8-1) Kd(W hd Directionality Factor)= 0.85 ( Table 26.6-1) Ke(Ground Elevation Factor)= 1.00 V(Design W hd Speed)=115 mph ( Fig.26.5-1A) Risk Category=II ( Table 1.5-1) qh= 25.95 psf Standoff Uplift Calculations-Portrait Zone 1 Z one 2 Z one 3 P ositive ya= 0.67 0 .77 0 .80 0 .67 GCp= - 1.45 - 2.41 - 3.10 0 .44 ( Fig.30.3) Uplift Pressure= - 25.2 psf - 48.2 psf - 64.3 psf 7 .7 psf ( Eq.29.4-7) ASD Uplift Pressure= - 15.1 psf - 28.9 psf - 38.6 psf 9 .6 psf X Standoff Spacing= 4 .00 ft 4 .00 ft 2 .67 ft Y Standoff Spacing= 6 .08 ft 3 .04 ft 3 .04 ft Tributary Area= 2 4.33 sqft 1 2.17 sqft 8 .11 sqft Dead Load on attachment= 7 3 Ib 3 7 Ib 2 4 lb Footing Uplift(0.6D+0.6W)= - 324 lb - 330 lb - 298 lb Standoff Uplift Calculations-Landscape Zone 1 Z one 2 Z one 3 P ositive Y.= 0.69 0 .79 0 .80 0 .69 GCp= - 1.49 - 2.48 - 3.20 0 .46 ( Fig.30.3) Uplift Pressure= - 26.7 psf - 51.0 psf - 66.5 psf 8 .3 psf ( Eq.29.4-7) ASD Uplift Pressure(0.6W p - 16.0 psf - 30.6 psf - 39.9 psf 9 .6 psf X Standoff Spacing= 6 .00 ft 6 .00 ft 4 .00 ft Y Standoff Spacing= 3 .50 ft 1 .75 ft 1 .75 ft Tributary Area= 2 1.00 sqft 1 0.50 sqft 7 .00 sqft Dead Load on attachment= 6 3 Ib 3 2 Ib 2 1 lb Footing Uplift(0.6D+0.6W)= - 299 lb - 302 lb - 267 lb Standoff Uplift Check Maximum Design Uplift=-330 lb Standoff Uplift Capacity =450 lb 450 lb capacity>330 lb demand Therefore,OK Fastener Capacity Check Fastener=1-5/16"dia.lag Number of Fasteners= 1 Embedment Depth= 250 in. Pullout Capacity Per Inch= 250 lb Fastener Capacity= 625 lb w/F.S.of 1.5&DOL of 1.6= (E7 lb 667.2 lb capacity>330 lb demand Therefore,OK Beers Arlington WA 3 Dom u S Dom us Structural Engineering, LLC STRUCTURAL P.O .Box 560 Broom field, CO 80038 N G T N F F. R T N G 1, 1. C: 530-864-7055 projects@dom usstruc.com Framing Check (M P1) w=72 plf Dead Load 7 .9 p;f PV Load 3 .4 p;f Snow Load 2 5.0 p&f 2x4 Top Chords @ 24"o.c. 0 Governing Load Combo=DL+SL Member Span=6'-4" Total Load 3 6.2 Isf Member Properties Member Size S(in^3) I(in^4) Lumber Sp/Gr Member Spacing 2x4 3.06 D 5.36 F#2 @ 24"o.c. i Check Bending Stress Fb(psi)= f 'b x C d x C f x C r ( NDS Table 4.3.1) 900x 1 .15x 1 .5x1 .15 Allowed Bending Stress=1785.3 psi Maximum M oment =(wL12)/8 = 353.2388 ft# = 4358.866 in# Actual Bending Stress=(Maximum Moment)/S =1423.4 psi Allowed>Actual--79.8%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = L/180 (E=1600000 psi Per NDS) = 0422 in Deflection Criteria Based on = Continuous Span Actual Deflection(Total Load) _ (w*L^4)/(185*E*I) =0.127 in = U599 >L /180 Therefore OK Allowed Deflection(Live Load) = L/240 0.316 in Actual Deflection(Live Load) _ (w*L^4)/(185*E*I) 0.088 in L1864 >L /240 Therefore OK Check Shear Member Area=F3 in^2 v(psi)= 180 psi ( NDS Table 4A) Allowed Shear = Fv*A =945 lb ax Shear(V)=w*L 12 = 2 29 lb Allowed>Actual--24.3%Stressed -- Therefore,OK Beers Arlington WA 4 Do m u S Dom us Structural Engineering, LLC S T R U C T U R A L P.O .Box 560 Broom field, CO 80038 ENGINEER ING LLC 530-864-7055 projects@dour usstruc.com Lateral Check Existing W Aght of Effected Building Level A e rea W ight(psi) W fight(lb) Roof 2800 sf 7.9 psf 2 1998 lb Ceiling 2 800 sf 6 .0 psf 1 6800 lb W and Siding 100 ft 5.0 psf 2 000 lb ( 8'-0"W Al Height) Int.W Als 1 00 ft 6 .4 psf 2 560 lb Existing W tight of Effected Building 43358 lb Proposed W tight of PV System W Aght of PV System(Per Blue Raven Solar) 3.0 psf Approx.Area of Proposed PV System 320 sf Approximate Total W tight of PV System 960 lb 10%Comparison 10%of Existing Building W tight(Allowed) 4336 lb Approximate W dght of PV System(Actual) 960 lb Percent Increase 2.2% 4336 lb>960 lb,Therefore OK Beers Arlington WA 5 Dom 11 s Dom us Structural Engineering, LLC STRUCTURA1, P.O .Box 560 E N G TNEER T N G 1. LC Broom field, CO 80038 530-864-7055 projects@dom usstruc.com Appendix A:G eieral Notes G ENERAL • The contractor shall verify all dim visions,property setbacks,AHJ/HO ACC&R's,elevations and site conditions before starting work and shall notify Dom is Structural Engineering,LLC of any discrepancies. • All report conclusions represent Dom cs Structural Engineering,LLC's best professional judgm vrt based upon industry standards. • Resolve any conflicts on the drawings with Dom Ls Structural Engineering,LLC before proceeding with construction. • The design criteria used for this project&listed on the first page of the report is based on the engineers best judgem Ent and/or provided by the ATC council.AHJ specific requests m aj differ.Please contact our team if the design criteria needs to be m odified. • A site visit was not physically conducted by Dom Ls Structural Engineering,LLC.The accompanying calculations and certification are provided with the understanding that the site building and construction standards m eat an acceptable level of industry standards.It shall be the contractors responsibility to identify any irregularities such as inconsistent fram hg conditions,water damage,fire damage,cracked,split or noticeably deflecting fram Ing m en bers. • Dom us Structural Engineering,LLC is not responsible for enforcing safety measures or regulations.The contractor shall design,construct,and maintain all safety devices including shoring and bracing,and shall be solely responsible for conform hg to all local,state and federal safety and health standards,laws and regulations.The contractor shall take necessary precautions to m antain and insure the integrity of the structure during construction.If a lawsuit is filed by one of the contractor's or subcontractor's em ployees,or any one else,the contractor will indem rify,defend and hold the owner and Dom Ls Structural Engineering,LLC harm less of any and all such claim s • Any and all waterproofing shall be provided by the contractor.Dom is Structural Engineering,LLC is not responsible for waterproofing. • All hardware shall be installed per m arufacturer specifications and within specified design Iim Cations.Dom Ls Structural Engineering,LLC assum es no responsibility for incorrectly installed hardware or hardware installed outside of the m arfacturer specifications. USER RELIANCE Dom us Structural Engineering,LLC was engaged by Blue Raven Solar(Client)to perform this assessm Ent.This report and the inform ation therein,are for the exclusive use of the Client.This report has no other purpose and shall not be relied upon, or used,by any other person or entity without the written consent of Dom us Structural Engineering,LLC.Third parties that obtain this report,or the information within shall have no rights of recourse or recovery against Dom Ls Structural Engineering,LLC,its officers or em ployees. RO O FM O WED ARRAYS If an analysis of a supporting stucture is included in our scope of work,the structural assessm ert only applies to the section of the roof that is directly supporting the proposed solar PV system. No structural m en bers can be cut for conduit,etc.,unless specifically shown.O[fain prior written approval for installation of any additional conduit,etc. It is assumed that a standard quality of construction care was used to construct the original building.It shall be the contractors responsibility to field verify any and all fram hg m vn bars supporting the proposed PV array are in adequate condition.The contractor shall field inspect for sub-standard construction m vans,signs of dry rot,m dd,fire dam age,etc.and notify engineer if any com prom bed material is found on site prior to starting construction. It is assumed that there have been no additional loads(HVAC or M EP equipm ert,additional layers of roofing,etc)added to the building over the course of the structure's histroy.The contractor and/or client shall verify this with the property owner and notify Dom u;Structural Engineering,LLC if additional load has been added to the structure already. Flexible utility connections m Let be used at any building seism b joint. Care should be taken to ensure that PV arrays do not preclude drainage of rain water. Unless otherwise noted,construction material shall be evenly distributed if placed on framed floors or roofs.Loads shall not exceed the allowable loading for the supporting m en bers and their connections. All lags or wood screws at the roof shall be stainless steel and installed withing the m ddle 1/3 of the dim eisional width of the fram hg m vn bers. All fasteners shall be a m him un of 6"away from any truss panel or hinge joints,truss plates and/or m en bar ends.Field verify location of fasteners prior to starting construction.All fasteners shall be pre-drilled to avoid splitting existing Ium bar. Dom us Structural Engineering,LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array nor any dam age to downslope decks,roofs,walkways,landscaping,autom chiles,pets,people,etc..If snow guards are requested by the custom er,notify Dom u;Structural Engineering,LLC. Beers Arlington WA 6 RESIDENTIAL RO O R-O P SOLAR PERMIT PACKAGE Enphase Platinum BLUE RAVEN eileen beers 10 1403 IN 630 E Installer g0LAR 17322 84th Ave NE Orem, Utah 84097 PV Installation SUN POWER' (800) 377-4480 Professional Arlington, Washington 98223 BlueRavenSolar.com C evil Lopeman #042013-75 4256980563Authorized SC O E OFWORK _ SHEET INDEX I NSTALLATIO N O F RO O Ff0 P M O UNTED - _ PV1 C O\ER SHEET PHOTO V O11AIC SOLAR SYSTEM - - ` - = � PV2 SITE PLAN } t PV3 ROOFPLAN U PV4 STRUC IURAL cy } PV5 ELEC 1RIC AL 3-LINE CV N PV6 ELEC 1RIC AL C ALC LLATIO NS 00 N PV7 LABELS t/>t Lu Q` Q PV8 PLACARD i Z E 3 SS SPEC SHEETS > 0 v co Q ._ Cn0 • U Q C O a a O z g � O U TYPIC AL STRUC URAL INFO RMATIO N NEW PV SYSTEM INFORMATION TOTAL PV DC SYSTEM SIZE T OTAL PV AC SYSTEM SIZE Q � ROOFMATERIAL: CcmpShingle DC SYSTEM SIZE: 6.3 kW DC 6300 kW DC 4875 kW AC PRO.IECTID:U . . SHEATHING:OSB AC SYSTEM SIZE: 4.875 kW AC 1002663 FRAMING:Manufactured Truss RAC IQNG:UNIRAC SFM INFINITY MODULE TYPE: (15) Silfab Solar SIL-420 Q D A. Cql DESIG N C RTERIA PV DC SYSTEM SIZE: RO0 FATTACHMENT: UNIRAC SFM INFINITY FLASHKIT INVERTER TYPE: (15) Enphase IQ 8M-72-M-US O� Of Wi j� j'�, WIND SPEED: 1 10 6.300 kW DC TOTAL ATTAC HM ENTS: 22 1 �C�' ti �� WIND EXPO SURE FAC 10 R C PV AC SYSTEM SIZE: ' RISK C ATEG O W: 11 4.875 kW AC GENERAL NO IES G R O IIND SNO W LO AD: 25 REVISIONS: Sealed For RO O FSNO W LO AD: 25 ---- SEISM IC DESIG N C ATEG O Rf: D Existing Roof & ibose 0 ____ Attachm ent O dy '`�rs�o'sr>�x� W EATHER STATIO N DATA 0 n'VAL W EATHER STATIO N: BO BNG FLD KING C O 0 HIGHTEMP2%AVG:29'C 7/1/24 Digitally signed EXTREMEMINIMUMTEMP: -70C DRAWN BY: by John A. Calvert Brendan Fillmore PLO T DATE: AHJ Date: 2024.07.01 APPLIC ABLE C O IES June 29, 2024 C �y of Arlington WA ' * DRAWING TITLE: 07:49:23 -06 00 2023 NATIONAL ELEC 1RIC COD(NEC) *2021 INTERNATIONAL BUILDING C O EE (IBC) Cover Sheet *2021 INTERNATIONAL RESIDENTIAL C O EE (IRC),2021 UNIFORM PLUMBING UTILITY C O MANY C O EE (UPC),AND ALL STATE AND LOCAL BUILDING,ELEC 1RIC AL,AND PLUMBING C ODES DRAWING NUMBER: Snohomish C aunty Public Utilities District (PUD) PV1 BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com ® ® ® E3 U ❑ U co } w N N CV ® ® ® ® I 00 Q LU H w o- N O Z Z c } ® ® El ® N O 0 } • ❑ _ > Li o ❑ I LL U ❑ I � Q 0- N Sealed For Q) N o } 0 ❑ co Existing Roof & •— coo ,>' 0 Attachm ent O dy 0) U ❑ ❑ I � L U Q N \ MSP I O \ CB C M / J •1p, Cq Zo ti ♦- y � .. J / / u a PRO.EC TID: / 1002663 PV DC SYSTEM SIZE: 6.300 kW DC PV AC SYSTEM SIZE: 7/1/24 4.875 kW AC REVISIO NS: NEW 0 ---- PV SYSTEM 0 SITE PLAN 0 ---- SC ALE: 1/16"= 1'-0" 0 ---- D LEG END PV SYSTEM SPEC FIC ATIO NS C O MASS DRAWN BY: Brendan Fillmore BREAKER FIRE SETBAC K TRENC HOR NEW PV SYSTEM INFORMATION N PLOTDATE: UTILITY METER BE ENC LOSURE [BAT] ESS- BATTERY ❑ HATCH OVERHEAD PV MODULE: (15) Silfab Solar SIL-420 Q D, POW It RATING:420 W June 29, 2024 INVERTER: (15) Enphase IQ8M-72-M-US, POW It RATING:325 W DRAWING TITLE: MSP MAN SERVICE PANEL AC AC DISCONNECT ESC ESS-C O INTRO LLER MIC RO INVERTER i PROPERTY LINE I E Site Plan PV PRO DUC ION REMOTE POWER ROOFTOP W [SUB] SUBPANEL PV METER FRP—O] O FF SWITC H , JUNC TO N BOX DRAWING NUMBER: 17-7q UTILITY ICOfllWIN DO1RL O 910 PV2 11\1CT CTCABI ETR CB COMBNER BOX ATS ATS PANELL INV INVERTER INDIC 4TEINTERIORLOCiP10N I S BLUE RAVEN SOLAR 1403 N 630 E 3- Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com Ll - U ❑ N 0 o i 00 z c a w � � o ❑ . Q � } ® ® ® U � V o ❑L ❑ _LL- � 00 Q ❑ ❑ O NNE o } ° •� U M Pl z U 16„ L MODULE QTY: 15 O Q N AZIMUTH: 272 ❑ �/ O PITC H 27 LL- TSRF: 83 y O AREA: 898 ft2 A►• C,q z ❑.. ❑ Sealed For p� of w �� G� N 3 o Existing Roof & L Attachm Ent O dy " a PROIC TID: ❑ ❑ - 1002663 RAC S•TER� PV DC SYSTEM SIZE: ss L �,�, 6.300 kW DC PV AC SYSTEM SIZE: r-- 1 7/1/24 4.875 kW AC M SP i PO NT 0 F INTERC O NNEC 110 N REVISIO NS: C B UNDERGRDUNDSERVICELINE NEW �AAQ�M PV SYSTEM 0 ---- RO O FPLAN 0 ---- SC ALE: 1/8"= V-0" Q D LEG END PV SYSTEM SPEC FIC ATIO NS C O MASS DRAWN BY: Brendan Fillmore BREAKER FIRE SETBAC K TRENC HO R NEW PV SYSTEM INFORMATION N PLOTDATE: UTILITY METER [BE] ENC LOSURE [BAT] ESS- BATTERY EIHATC H OVERHEAD PV MODULE: (15) Silfab Solar SIL-420 QD, POW ER RATING:420 W June 29, 2024 INVERTER: (15) Enphase IQ8M-72-M-US, POW It RATING:325 W DRAWING TITLE: MSP MAIN SERVICE AC AC DISCONNECT ESC ESS-C O INTRO LLER MIC RO INVERTER i PROPERTY LINE PANEL , W E Roof Plan SUBPV PRO DUC ION FRP—O REMOTE POWER , ROOFTOP SUBPANEL rpv] TLINE DRAWING NUMBER: METER O FF SWITC H JUNC TO N BOX ICOfll WIN DO1RL O 910 11\1CT CTCABI ETR CB COMBNER BOX ATS ATS PANEL INV INVERTER INDIC 4TEINTERIORLOC<PION IPV3 S C BLING JO BT/ MAXIMUM MAXIMUM TOTAL PV ARRAY AREA(W) 314.99 PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE ROO FMATERIAL S HEATHING TYPE F RAM ING TYPE PURLINS SIZE RAC IGNG TYPE A TTAC FM ENT TYPE ATTAC FMENT CANTILEVER TOTAL ROO FAREA[W) 2804 C O WT (DEG) (DEG) (%) (ft') AND SPAC NG AND SPAC NG SPAC NG(S) (C) DISTRIBUTED LOAD(psf) 2.2 MPI 15 2 72 2 7 8 3c8 98 C mp Shingle O SB M anufactured Truss 2 x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY U NIRAC SFM INFINITY FLASHKIT 7 2"L/48"P 2 4"L/16"P ROO FC O%ZRAG E(%) 11.23 MP2 0 TOTAL PV ARRAY WEIGHT(Ibs) 694.5 MP3 0 TOTAL PV ATTAC FMENTS 22 BLUE RAVEN MP4 1 0 POINT LOAD(lbs/aft.) 31.6 S O LA R M P5 0 M P6 0 1403 N 630 E MP7 0 Orem, Utah 84097 M P8 0 377-4480 MP9 0 BlueRavenSolar.com MPIO 0 ATTAC WENT TYPE: PV MODULES SHALL NOT EXTEND Unirac SFM Infinity ABOVE RO 0 FRIDG E LINE PV MODULE MAX C ANTILEVER } PER TABLE ABOVE— (C) N UNIRAC UNIRAC N 0 PV MODULE SFM INFINITY SFM INFINITY 00 2"MICRORAIL 6.5"SPLICE H � LU O Q � O � ROOFMATERIAL NOT EXISTING FRAMING Q a SHOWNFORCL4RITY = — °° Q p 2y"MINIME N 0 (1)5/16"LAG BOLT EMBEDMENT _ WITH EPDM WASHER O .� C: wW U ATTAC H\AENT SPAC NG — U PER TABLE ABOVE N_ FRAMING SPAC NG *THIS DETAIL IS NOTMEANT TO BE PER TABLE ABOVE O� 1 FRAMING DETAIL EXTERIOR WALL AN EXACT REPRESENTATION OF 2 ATTAC WENT DETAIL r O SC ALE: 1/2"= 1'-0" SC ALE: 1-1/2"= 1'-0" a z FRAMING O R PV MODULE LAYO UT Z - N RIDG E ° NOTES f u o r LAN DSC APE PO RTRAIT U a PRO IC TID: 1002663 PV DC SYSTEM SIZE: 6.300 kW DC PV AC SYSTEM SIZE: 4.875 kW AC REVISIO NS: Sealed For 0 Existing Roof& A• C 0 ---- Attachm ent O dy �`�`�ov why l GEC+ 0 ---- t61 DRAWN BY: `T Brendan Fillmore PLOT DATE: June 29, 2024 "056�l �4 DRAWING TITLE: ss�ONAL Structural FO LLO W ATTAC WENT SPAC NG IN TABLE ABO VE EAVE *ATTAC WENT PATTERN SHOULD BE 7/1/24 DRAWING NUMBER: ATTAC FM ENT PATTERN STAGGERED UNLESS OTHERWISE �vJ SCALE: 1/4"= 1'-0" NOTED IN ENGINEERING LETTER P v "T L1 (1) 6AWGTHHN/THWN-2CUBLACK 1-1 (1) IOAWGTHHN/THWN-2CUBLACK Ll (2) 10AWGTHHN/THWN-2CUBLACK 3/41NC H L1 (1) IOAWGTHHN/THWN-2CUBLACK 3/41NC F 1-1 (1) 12AWGTHHN/THWN-2CUBLACK 5 L2 (1) 6 AWGTHHN/THWN-2 CURED L2 (1) 10 AWGTHHN/THWN-2 CURED 3 L2 (2) 10AWGTHHN/THWN-2CURED EMT 2 L2 (1) 10AWGTHHN/THWN-2CURED L2 (1) 12AWGTHHN/THWN-2CURED N (1) 6 AWG THHN/THWN-2 C U WHITE N (1) IOAWGTHHN/THWN-2CUWHITE G (1) IOAWGTHHN/THWN-2CUGREEN G (1) IOAWGTHHN/THWN-2CUGREEN G (1) 6AWGBARE,CU G (1) I0AWGTHHN/THWN-2CUGREEN *TYPE UFCABLEMAYBESUBSTITUTEDFORUSEIN "TYPE NM(ROMEX)/UFCABLEIS PERMITTED FORINTERIOR 3/4 INC H RMC or PVC Sch 80 Exterior 3/4 INC H EMT Exterior C O NDUIT W HERE NEC C O DPERMTS O R ATTIC RUNS AND SHALL BE USED WHEN NEC C O DPERMFS ENPHASE Q-C ABLE,2-WIRE,FREE AIR Exterior BLUE RAVEN SOLAR 1403 N 630 E O rem, Utah 84097 (800) 377-4480 BlueRavenSolar.com PRIMARY PV C O MBdER BOX OE 15A O PRIMARY STRUC URE-0 AC DISCO N1EC T O O(15)PV MOOl1LES oB &MIC RD INVERTERS SAFETY SWITCH (N)20A Al PV C RC UT 1 I©I Utility Meter (E)200A Main Service Panel O6 A FUSIBLE — — PV ARRAY 0 F O ENVOY F SMOCl1LES, I 2 I 11 (N)20A I I I } (E)200A N I I PV C RC UT 2 I U (EL) r--_ G _ 7MODULES� L 30A I Y. 2 L J (�J N FUSES _ (EL) Ll G J 00 L2 H L U N N Z > } (EL) 5 G -- G — � O _-- -------------------------- — ------------------- 4 A, O t C (EL) I SUPPLY SIDE TAP /W Q 0 NEC 250.24(A) ii 0) U BO ND G RO UN DS (EL) AND NEUTRALS � >� i Q N N > I N O 4- 0 .� r U G I — y UNDERG R O I11D SERVICE I O 120/240 VAC,60 Hz O 1 PHASE,3 WIRE  L z 0 GENERAL NOTES Z 0 N � o Utility Meter Number:67537407 a f U O } Supply side tap.Interior PO L 9 U Q LEG END PROJECTID: (E) EXISTING (PV) PV BREAKER 1002663 (N) NEW (FIB) FACTORY INSTALLED BREAKER (EL) EXISTING LOADS SPD SURGEPROTEC1VE DEVICE PV DC SYSTEM SIZE: (RL) RELOCATEDLOADS MI MECHANICAL INTERLOCK 6.300 kW DC EQ UPM ENT NOTES EQ UPM ENT DESC R PTIO NS PV AC SYSTEM SIZE: OFINAL CO NFIG URATIO N O F PV C RC UTS TO BE DEC DED BY INSTALLER.M UST C O M PY WITH MAX OA PV MO DULE:Silfab Solar SIL-420 Q D,420 W DC,UL 1703/UL 61730 C O M 21ANT 4.875 kW AC MIC ROINVERTERS PER C RC UT AS LISTED 0NATTAC FED SPEC SHEET. ©MIC RD INVERTER:ENPHASE IQ8M-72-M-US,325 W AC(0.325 kW),1 PHASE,UL 1741 C O M EIANT REVISIO INS: O2 ©RO0TOPJUNC10NBOXEZSOLARJB-1.2JUNC110NBOX QA ---- O @JUNC10NBOX PVC 4X4JUNCTONBOX ---- 3 O BIER PV C O M ER BO X ENPHASE C O M INER 5(X-IQ_AM 1-240-5) B O0 SQ UARE-D SAFTEY SWITC H60A,2P,240VAC,FUSIBLE(D222NRB) Q ---- © D - O o D --- 1 DRAWN BY: 0 Brendan Fillmore OO PLOT DATE: O6AWGSO LID C0fFERGECTOBE IRREVERSIBLY SPLICEDTO(E)GECT000MPY WITH NEC © June 29, 2024 250.64(D)(1). DRAWING TITLE: OTHER N01ES Electrical O9 G RD 11NDING ELEC 1R0 DE SYSTEM SHALL BE IN AC C O @ANC E WITH NEC 250.53. O ,o © 3-Line ® DRAWING NUMBER: 11 ALLINTERIORC0NDUITMUSTBESCH80PVC. PV5 12 O ELEC 1RIC AL INFORMATIO N PV BREAKER BAC DEED C ALC 11ATl0 NS DESIG N LO C 910 N UTILITY ELEC IRIC AL SYSTEM NEC 705.12(B)- 120%RULE' AND TEMPERATURES BLUE RAVEN_ I-Phase,3-Wire,60Hz, 1201240V (BUSBAR RATING*120%)-OC FD RATING=AVAILABLE BAC KFEED DATA SOURCE ASHRAE Weather Station Data NEW PV SYSTEM MAIN SERVIC E SUBPANEL 1 S UBPANEL 2 STATE Washington 1403 N 630 E I-Phase,3-Wire,60Hz, 1201240V PANEL C FY Arlington AC SYSTEM SIZE 4.875kW AC BUSBAR RATING 200A ----A ----A WEATHER STATIO N BO BNG FLD KING C O O rem, Utah 84097 DC SYSTEM SIZE 6.3kWDC PANEL 0CR)RATING 200A ----A ----A HIG HTEM P 2%AVG 29°C (800) 377-4480 AVAILABLE BAC ITEED(120%RULE) 40A ##A ##A PV MODULES PV BREAKER RATING 30A 30A 3 OA EXTREME MINIMUMTEMP -7°C BlueRavenSolar.com O UANTITY 15 TYPE Silfab Solar SIL-420 Q D *THESE C A LC LLATIO NS ARE O NY APPLIC ABLE IF PV INTERC O MlEC TO NIS A W ATTAG E 420W DC LOAD SIDE BREAKER.*PV BREAKER M UST BE RATED LESS THAN O REO UAL TO AVAILABLE BAC ITEED FO RC CDE C O M BANC E' MIC RD INVERTERS TYPE Enphase IQ8M-72-M-US OUTPUT C IRRENT 1.35A AC Q NOMINAL VO17AG E 240V AC O UFPUT PO W 61 325W AC U WIRE SIZE SPEC FIC ATIO NS N N 0 (D-1 0 (D © 0 ® 10 00 MINIMUMC0M1UC10RAMPACFY I 3.5AAC 13.5AACI 3.5AAC2 5.31AAC2 5.31AAC- ---AAC- ---AAC- ---AAC- ---AAC- ---A AC L LU C 0 NDUC 10 RMATERIAL CU CU CU CU CU -- — -- -- — _} C 0 NDUC 10 RTYPE THHN/THWN-2 THHN/THWN-2 HHN/THWN-2 HHN/THWN-2 HHN/THWN-2 O C0 NDUC73RSIZE 12AWG 10AWG 10AWG 10AWG 6AWG w/ _ C 0 IDUC 10 RAM PAC FY 30A 40A 4 OA 4 OA 7 5A- ---A- ---A- A- ---A- ---A AMBIENT TEMPERATURE ADJUSTMENT FACIOR 1 1 1 1 1- -- — -- -- N C O M)UIT FILL ADJUSTMENT FAC 10 R 1 1 0 .8 1 1 - O i ADJUSTED C O IDUC 10 R AM PAC FY 30A 40A 3 2A 4 OA 7 5A- --A- --A- -—A- --A- --A 0o > Q D W IRE RUN DISTANC E(FT) 52 55 20 5 10- -- - -- - -- - -- - N CALCILATEDVO[TAG E DRO P 0.52%0 .61%0 .22%0 .1%0 .08%0 %0 %0 %0 %0 % M 4__.� o PV C RC UT SPEC FIC ATIO NS U U PRIMARY STRUC URE D ETAC FED STRUC URE L CRCUTI CRCUT2 RCUT3 RCUT4 RCUT5 RCUT6 RCUT7 RCUT8I RCUT1 C RC LIT 2 RC LIT 3 RCUT4 RCUT5 Q N NUMBER O FMODULES PER C RC UT 8 7 0 0 0 0 0 0 0 C 0 0 RATED AC O UFPUT C U2RENT(Iou) 10.8A 9 .5A 0 .OA 0 .OA 0 .OA 0 .OA 0 .OA 0 .OA O.OA 0 .OA 0 .OA 0 .OA 0 .OA O MINIMUMAMPAC FY(Iou x 125%) 13.5A 1 1.8A 0 OA 0 OA 0 OA 0 OA 0 OA 0 OA O.OA 0 OA 0 OA 0 OA 0 OA - O VERC IRRENT PRO TEC 10 N RATING 20A 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA O C O MBJED AC O UFPUT C URRENT(Cou) 20.3A O.OA z C MINIMUMAMPAC FY(Cou x 1257.) 25.3A O.OA z -9 N C0MBIED PV BREAKER RATING 30AA OAA 0 f U O r TO TAL J chi a OIC TID: VO LTAG E DRO P PR1002663 VO[TAG E DRO P WIRE TAG#1 0.52% WIRE TAG#2 0.61 PV DC SYSTEM SIZE: W IRE TAG#3 0.22% WIREIN— 0.1% 6.300 kW DC W IRE TAG#5 0.08% PV AC SYSTEM SIZE: W IRE TAG#6 0% 4.875 kW AC TOTAL 1.530000% REVISIONS: ---- A ---- A ---- BRAWN BY: Brendan Fillmore PLOT DATE: June 29, 2024 DRAWING TITLE: Electrical C dculations DRAWING NUMBER: PV6 WARNING LABELS BLUE RAVEN SOLAR UTILITY METER MAIN SERVIC EPANEL AC DISC O MEC T 1403 N 630 E Orem, Utah 84097 (800) 377-4480 •T•V OFAIC SYSTEM BlueRavenSolar.com DISCOA AC RATED AC 0 UfPUT CURRENT 20.3 A NO MNAL 0 FERATING AC VO LTAG E 240V &WARNING ELECTRIC SHO O<HAZARD TERM NALS O NTHE LINE AND } LOAD SIDES MAY BE ENERG QED .0 IN THE 0 PEN PO STIO A PV C O M IN ER BOX } N N SO LAIR PV SYSTEM EO UPPED 04 0 WITH RAPID SHUTDO W N C0 RAPID •• H LL.L TURSWITCH TO THE W • ' • ' PHO T O V OF&IC SYSTEM L Z c 3 SWITCH TO THE U D"PO STIO INTO SHUTDOW WV SYSTEM CO M®NER PANEL 0 AND REDUCE } SN THE HAZARD & WARNING Q IN THE ARRAY. AUTHO RZED PERSO NVEL O NLY 00 Q DO NO TADD LOADS N NO DC WIRES PRESENT W N - a RAPID SHUTDOW N co } •A�, � � TEST NO TREO URED W 0 U U Q � N 0 -K-- O z � z � N O f U O r U Q PRO.EC TID: A CAUTIO N 1002663 M U-TIPLE SO URCES O FPO W ER PV DC SYSTEM SIZE: POW ERTO THIS BUILDING IS ALSO SUPPLIED FRO MA RD 0 FM 0 UNTIED 6.300 kW DC SO IAR ARRAY.PV DISCO NJECT IS LO CATED WITHIN 10 FT AND LINE PV AC SYSTEM SIZE: O FSIG FR O FUTILITY M EFER. 4.875 kW AC REVISIO INS: A ---- OWARNING DUAL POW ER SUPPLY A SO URCES:UTILITY G RD AND PV SO LAR ELECTRIC SYSTEM DRAWN BY: Brendan Fillmore PLOT DATE: June 29, 2024 IN CASE O FEM6ZG EVCY, DRAWING TITLE: PLEASE CO NrACT: BLUE RAVEN SO LAR Warning (800)377-4480 Labels DRAWING NUMBER: P V 7 11� ELECTRICAL SPECIFICATIONS 4 420 BLUE RAVEN Test Conditions S STC NOCT _ TC N OCT SOLAR Module Power(Pm ao W p 420 313 30 3 21 • Maxim u rrpowervoltage(Vpm a(�V 33.08 30.86 3.25 3 1.02 ••• ••••• Maxim u rrpower current(Ipm a() A 12.70 30.15 2.93 1 0.33 ••• Open circuit voltage(Voc) V 38.84 36.52 8.91 3 6.58 SILFABS I L FA B • Short circuit current(Isc) A 13.50 10.85 3.87 1 1.15 PRIME O L A R® Module efficiency % 21.5% 20.1% 2.1%2 0.6% Maxim u rruystem voltage(VDC) V 1000 SIL-420/430 QD Series fuse rating A 25 Power Tolerance W p 0to+10 Measurem ett cond itions:STC 1000 W 02 2•AM 1.5•Tem perature 25°C•NOCT Boo W tn'•AM 1.5•Measu rem ett u ncertai my<_3% Sun sim Bator calibration reference m odules from Frau nhofer Institute.Electrical characteristics m aj vary by±5%and power by 0 to+10 W. MECHANICAL PROPERTIES/COM FOMENTS M ' Moduleweight 2 1 kg±0.2 kg 4 6.3IDS±0.4lbs Dimeisions(HxLx D) 1 721 m mx 1133 m mx 35 m m 67.8 in x 44.6 in x 1.37 in Maxim u nsurface load(wind/snow)* 4 000 Pa rear load/5400 Pa front load 8 3.5 lb/ft2 rear load/112.81b/ft2 front load Hail impact resistance a 25 m mat 83 km/h a pin at 51.6m ph Cells 108 Half cells-N-Type Silicon solar cell 108 Half cells-N-Type Silicon solar cell 182mmx91mm 7.16 in x 3.58 in Glass 3.2 m mhigh transm ttance,tem pered, 0.126 in high transm trance,tem pered, antireflective coating antireflective coating Cables and connectors(refer to installation m aival) 1 350 m m o 5.7 m m f4C4 from Staubli 5 3.1 in,a 0.22 in(12 AW Q,MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,m tlti-layer dielectric film, fluorine-free PV backsheet Fram a Anodized alum hum(Black) Junction Box U L 3730 Certified,IEC 62790 Certified,IP68 rated,3 diodes TEM PERATURE RATINGS C WARRANTIES Temperature Coefficient lsc 0 .04%fC Module product workm alship warranty 2 5years** Temperature Coefficient Voc - 0.24%fC Linear power perform ante guarantee 3 0years Tem perature Coefficient Pm a( - 0.29%fC >_98%end lst yr NOCT(±2°C) 4 5°C >94.7%end 12th yr >_90.8%end 25th yr Operating temperature - 40/+85°C >_89.3%end 30thyr CERTIFICATIONS SHIPPING SPECS UL 61215,UL 61730,CSA C22.2#61730,IEC 61215,IEC 61730,IEC 61701(Salt Mist Modules Per Pallet: 2 6 or 26(California) Product Corrosion),IEC 62716(Am m olia Corrosion),CEC Listed,UL Fire Rating:Type 2 Pallets Per Truck 3 2 or30(California) Factory I S09001:2015 Modules Per Truck 8 32 or 780(California) * A W aning.Read the Safety and Installation Manual for m writing specifications and before handling,installing and operating In cdules. 1 2 year extendable to 25 years subject to registration and conditions outlined under"W aranty"at sitfabsolar.com. PAN files generated from 3rd party perform ante data are available for download at:silfabsolar.com/dow doads. 67.8"[1721 m m] E v E �M 11.8"[300.5m m] 44.1"[1120m m] 11.8"[300.5m m] INTRO D9ING NIKT- GENERATION ° 0.5" •• y cunting Hole(x4) • N -TYP E CELL TEC H N 0@G Y [12mm] SILFAB SOLAR INC. • Im proved Shade Tolerance Enhanced Durability 1.4"[35mm1 1770 Port Drive • Improved Low-Light Performance Reduced Degradation Rate �' o E b E e Burlington W A98233 USA -6 -�o o E E T+1360.569.4733 • Increased Performance in Industry-Leading W aranty m ? _M info@silfabsolar.com High Tem peratures SILFA B S)LA R.CO M u o 3 0.06" v 7149 Logistics Lane [1.Smm] : - E= Fort Mill SC 29715 USA N rn T+1839.400.4338 • y 5 • • 53.15" 0� 240 Courtneypark Drive East S I L F A B 8J LA R C 0 M • [1350m m] c' Mississauga ON L5T 2Y3 Canada • Cable Length c C7 T+1905.255.2501 • • rainage Hole(x8) F+1905.696.0267 a O C Ffffl [ a Silfab-SIL-420/430-QD-20240227 DRAWING NUMBER: No Ei� IEC p p I~ 2.4"[60mrn 8"[200mm] Daaandinftionofanissubjsallowedwcationswithhout perno scion. Dotaand informolarI ssubject tomoSolar-sa without SS � • notice.©Silfab5olarinc.,2022.Silfab Sonar®isa registered I nh•i lek • • tradem ak of Silfab Solar Inc. 4� 4 - de U N I RAC BLUE RAVEN April 11"',2024 SOLAR To Whom It May Concern, This letter is confirm lion that the Silfab SIL-xxx QD m mule is com latible with Unirac's SFM racking system. The Silfab SIL-xxx QD m alule has been reviewed to ensure that,when installed with SFM,all structural and grounding and bonding features of the racking system mto properly with the m odule's fram e Silfab SIL-xxx QD is UL fire rated as a Type 2 m odule, for which the SFM system is UL 2703 certified. The Unirac product warranty applies to the installation of the Silfab SIL-xxx QD m odule with SFM. Please contact Unirac with any questions. Regards, A'404t7�' "Z e Robert D'Anastasio Validation Engineer robert.danastasio@mirac.com Unirac, Inc. * www.unirac.com DRAWING NUMBER: 1411 Broadway Blvd. NE • Albuquerque, NM • 87102-1545 • Ph: (505) 242-6411 • Fax: (505) 242-6412 S ENPHASE m IQ 8 K&nd IQ 84 M broinverters BLUE RAVEN SOLAR INPUT 1ATA(DCI U NITS 108M-72-M-US1 C on m mlly used m odule pairings' w 260-460 95-500 fill M odule com patibility Tom eat compatibility,PV modules m(st be w thin the follow hg m a(im u rrinput DC voltage and m a(im u m mdmle I x. 1 b M odule com patibility can be checked at https://enphase.com Anstallers/m broinverters/calculator M FPT voltage range V 30-45 2-45 0 parating range V 16-58 \ M him u m IA a(im u rrstart voltage V 22/58 M acim u rrinput DC voltage V 60 M adm u ncontinuous input DC current A 12 M ecim u mnput DC short-circuit current A 25 M a(im u m ndmle I A 20 1 O eervoltage class DC port II S - ti DC port backfeed current mA 0 PV array configuration 1 x 1 ungrounded array;no additional DC side protection required;AC side protection requires m a(20 A per branch circuit OUTPUT 1' A: A: Peak output power VA 330 66 M a(im u noontinuous output power VA 325 49 Q 8 W n d IQ 84. M broinverters Nom hal grid voltage(L-L) v 240,split-phase(L-L),180' M him u nand M a(im u ngrid voltage2 v 211-264 O u-newest IQ 8M broinverters are the industry's first m brogrid-form hg,software- M a(im u rrcontinuous output current A 1.35 .45 defined m broinverters w th split-phase power conversion capability to convert DC Easy to install Lightweight and com ct w th plug- is Nom hal frequency Hz 60 power to AC power effi dently.The brain of the sem bonductor-based m broinverterPa P S- and-play connectors Extended frequency range Hz 47-68 is our proprietary application-specific integrated circuit(ASIC)w fich enables the m broinverter too operate in rid-tied or off-grid m odes.This chi Is built using Power line communication(PLC) AC short-circuit fault current over P 9 9 P• 9 between com ponents Arms 2 advanced 55-nm technology w th high-speed digital logic and has superfast Faster installation w th situ ple two- three cycles response tim es to changing loads and grid events,alleviating constraints on battery w le cabling M e(im u rrunits per 20 A(L-L)branch 11 sizing for hom eenergy system s circuit3 High productivity and reliability Total harm uric distortion % <5 Produce power even w han the grid 0 tervoltage class AC port III is dow rt Enphase M cre than one m Ilion cum dative AC port backfeed current mA 30 hours of testing *-m2 5 Power factor setting 1.0 C Liss II double-insulated enclosure O ptim eed for the latest high- G id-tied power factor(adjustable) 0 .85leading...0.85 lagging warranty 4 powered PV m odules peak effi dency / 97.8 7.7 Part of the Enphase Energy System,IQ 8Series IQ 85eries M broinverters redefine reliability M icrogrid-form ng C E Qveighted effi dency % 97.5 7 M broinverters integrate w th the IQ Battery, standards w th m cre than one m Ilion IQ G ateway,and the Enphase App m mitoring and cum(Dative hours of power-on testing, C om plies w th the latest advanced Nighttim epower consum ption mw 21 2 analysis software. enabling an industry-leading lim ted warranty grid support** DATA of up to 25 years. Rem cte autom atic updates for the latest grid requirem Ents Am bent tem parature range - 40°C to 60°C(-40°F to 140°F) C mfigurable to support a w de Relative hum dity range 4%to 100%(condensing) range of grid profiles Meets CA Rule 21(UL 1741-SA)and IEEE DC connector type Staubli M 04 1547:2018(UL 1741-SB 3'd Ed.) Dim Ensions(H.W•D) 2 12 m m(8.3")•175 m m(6.9")•30.2 m m0.2") CERTIFIED NOTE: Weight 1.1 kg(2.43lbs) • IQ 8M broinverters cannot be m ked together w th C(Dling Natural convection-no fans C rnnect PV modules quickly and easily to the IQ 85eries M broinverters are UL Listed as previous generations of Enphase m broinverters IQ 8Series M broinverters that have integrated PV rapid shutdow nequipm art and conform (IQ7 Series,IQ 6Series,and so on)in the sam a Approved for wet locations Yes M C 4connectors. w th various regulations w Ien installed system. according to the m alufacturer's instructions. Pollution degree PD3 • IQ G 3eway is required to change the default grid profile at thetim eof installation to m eat the local Enclosure C lass II double-insulated,corrosion-resistant polymeric enclosure Authority Having Jurisdiction(AHJ)requirem arts. Environm vital category/UV exposure rating N EM AType 6/outdoor M eats UL 1741 only w len installed w th IQ System C mtroller 2. "IQ 8 Mand IQ8A support split-phase,240 V installations only. (D No enforced DC,AC ratio. (2)Nom hal voltage range can be extended beyond nom hal if required by the utility. DRAWING NUMBER: (3)Lim is m ar vary.Refer to local requirem arts to define the num bar of m broinverters per branch in your area. IQ 8 M AA C 4DSH-00205-2.0-EN-US-2023-11-03 10 8 M AM C 4DSH-00205-2.0-EN-US-2023-11-03 SS 11� Data Sheet Enphase Q Cable Accessories BLUE RAVEN Enphase Q Cable Accessories SOLAR REGION:Americas CO N W Cr0 RSPECIFICATIO N S Certification U L3003(raw cable),UL 9703(cable assemblies),DG cable Flametest rating F T4 Compliance R oHS,OIL RES I,CE,UV Resistant,combined UL for Canada and United States Conductor type T HHN/THWN-2 dry/w Et Enphase The Enphase Q Cable'm and accessories are part of Disconnecting means T he AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ System'm.These disconnect required by NEC 690. QCable Accessories accessories provide Sim plicity, reliability, and faster Q CA BLE TYPES/0 RDERING 0 PTIO NS installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing P V Module Orientation Connector Count per Box Q-12-10-240 12 AW G/277 VAC 1.3 m(4.2 ft) Portrait 2 40 Q-12-17-240 12 AW G/277 VAC 2 .0 m(6.5 ft) L andscape(60-cell) 2 40 Q-12-20-200 12 AW G/277 VAC 2 .3 m(7.5 ft) L andscape(72-cell) 2 00 EN PHA SE Q CA BLE ACCESSO RIES Name Model Number D escription Raw Q Cable Q-12-RAW-300 3 00 meters of 12 AW G cable w th no connectors Enphase Q Cable Field-w teable connector(male) Q-CONN a0M M ake connections from any open connector • Tw ow�e,double-insulated Enphase Q Cable Field-w�eable connector(female) Q-CONN 10F Make connections from any Q Cable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 U sed to fasten cabling to the racking or to secure looped cabling Enphase cable • New cable numbering and plug and play Disconnect tool Q-DISC-10 D isconnect tool for Q Cable connectors,DC connectors,and AC m odule m ount connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEAL-10 0 ne needed to cover each unused connector on the cabling w Fe m anagem ent • Link connectors eliminate cable w a3te Term inator Q-TERM-10 T erm inator cap for unused cable ends Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV m odule using MC4 connectors to IQ m icros w th EN4(TE PV4-S SOLARLOK). 150m mi5.9"to MC4. Enphase EN4 non-term hated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non-term inated cable.150m m/5.9" Field-W ireable Connectors Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use w th split cell modules or PV modules w th short DC cable.600mm23.6" • Easily connect Q cables on the roof w thout Replacement DC Adaptor(MC4) Q-DCC-2 D C adaptor to MC4(max voltage 100 VDC) com Alex w ping Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(m ax voltage 100 VDC) • Make connections from any open connector and center feed any section of cable w thin 1.Qualified per UL subject 9703. branch limits Available in male and female connector types TERMINATOR SEA LING CA P5 Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCO N N ST TO 0 L CA BLE CLIP Plan to use at least one per Used to fasten cabling to the racking installation,sold in packs often or to secure looped cabling,sold in (Q-DISC-10) packs of one hundred(Q-CLIP-1 00) To learn m are about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ To learn more about Enphase offerings,visit enphase.com E N P H A S E® Envoy, nvo,a bother trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. v E N P H A S E DRAWING NUMBER: SS ENPHASE IQ C cm Liner 5/5C BLUE RAVEN rr SOLAR IQ C an liner 5 w th IQ G aeway printed circuit board for integrated revenue-grade PV production 'r ✓ IQ C an liner 5(X-IQ-AM 1-240-5) In Bering(ANSIC 12.20±0.5%)consum ption m mitoring(±2.5%)and IQ Battery m mitoring U2.5%) Includes a silver solar shield to deflect heat. IQ C an Liner 5C w th IQ G aeway printed circuit board for integrated revenue-grade PV production IQ C an liner 5C(X-IQ-AM 1-240-5C) In Gering(ANSI C 12.20±0.5%)consum ption m mitoring(±2.5%)and IQ Battery In mitoring(±2.5%) Includes Enphase M cbile C mnect cellular m cdem(C ELLM O OEM-M-D6-SP-05)'.Includes a silver solar shield to deflect heat. WHAT'S IN THE :O IQ G aeway printed circuit board IQ G aeway is the platform for total energy m anagem Ent for com prehensive,rem its m antenance,and m anagem Ent of the Enphase Energy System Busbar 80 A busbar w th support for 1 x IQ G aeway breaker and 4 x 20 A breaker for installing IQ Series M broinverters and IQ Battery 5P IQ Gateway breaker C ircuit breaker,2-pole,10 A/15 A Production CT Pre-w Led revenue-grade solid-core CT,accurate up to±0.5% X-IQ-AM 1-240-5 C msum ption CT T wo consum ption m Bering clam pCTs,shipped w th the box,accurate up to±2.5% X-IQ-AM 1-240-5C IQ Battery CT O re battery m Bering clam pCT,shipped w th the box,accurate up to±2.5% CTRL board C ontrol board for w Led com In Ilnication w th IQ System C mtroller 3/3G and the IQ Battery 5P QC cm b n e r 5/5C Enphase M cbile C mnect(only w th IQ C an Liner 5C) 4G rased LTE-M lcellular m odem(C ELLM O OEM-M U6-SP-05)w th a 5-year T-M cbile data plan Smart Accessories kit S pare control headers for the CO M M SKIT-02 board The IQ C an liner 5/5C consolidates interconnection equipm Ent into a single enclosure and ACCESSORIES r rINCLUDED, ORDER stream Ines IQ Series M broinverters and IQ G aeway installation by providing a consistent, Includes IQ G aeway for pre-wired solution for residential applications.IQ C on liner 5/5C uses w led control com m unication and control C ELLM O OEM-My 106-SP-05 4 G-lased LTE-M lcellular m alem w th a 5-year T-M cbile data plan com rrunication and is com patible w th IQ System C mtroller 3/3G and IQ Battery 5P. Includes Enphase M cbile C alnect C ELLM O OEM-"6-AT-05 4 G based LTE-M lcellular m odem w th a 5-year AT&T data plan (C ELLM O OEM-M 1D6-SP-05),only The IQ C an liner 5/5C,IQ Series M broinverters,IQ System C mtroller 3/3G,and IQ Battery w th IQ C an liner 5C Supports Eaton BR2XX,Siem ens Q 2(X and G E/ABB THQ L21XX Series circuit breakers(XX represents 5P provide a com plete grid-agnostic Enphase Energy System. C Lcuit breakers(off-the-shelf) 10,15,20,30,40,50,or 60).Also supports Eaton BR220B,BR230B,and BR240B circuit breakers Supports flexible networking:Wi-Fi, com patible w th the hold-dow nkit. Ethernet,or cellular C Lcuit breakers(provided b Enphase) BRK-10A-2-240V,BRK-15A-2-240V,BRK-20A-2P-240V,BRK-15A-2P-240V-B,and BRK-20A-2P- Provides production m Bering P y P 24OV-S(m are details in the"Accessories"section) (revenue grade)and consum ption m mitoring XA-SO LARSHIELD-ES Replacem ant solar shield for IQ C an liner 5/5C XA-ENV2-PC 61-5 I Q G aeway replacem Ent printed circuit board(PC B for IQ C an liner 5/5C Easy to install X-IQ-NA-HD-125A Hold-dow nkit com patible w th Eaton BR-B Series circuit breakers(w th screws) IQ Series M broinverters IQ System C mtroller 3/3G M aints to one stud w th centered The high-powered sm at grid-ready IQ Series Provides m brogrid interconnection brackets XA-CO M M 2-PC Bar-5 Replacem art C 0 M M IT-02 printed circuit board(PCB for IQ C an Liner 5/5C M broinverters(IQ F I07,and IQ 8Series)Sim plify device(M D)functionality by Supports bottom,back,and side ELECTRICAL SPECIFICATIONS the installation process. autom etically detecting grid failures and conduit entries seam bssly transitioning the horn eenergy Rating 80 A system from grid power to backup power. Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers System voltage and frequency 1 20/240 VAC,60 Hz J (not included) Busbar rating 1 25 A W 80 A total PV branch circuits Fault current rating 10 kAIC Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup M wim u ncontinuous current rating(input from PV/storage) 6 4 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR,Siem ens Q,or G F/ABB THQ LSeries distributed generation(DG)breakers Reliable only(not included) iQ Battery SP IQ Load C mtroller Durable NRTL-certified NEM Atype 3R M acim u mtotal branch circuit breaker rating(input) 80 A of distributed generation/95 A w th IQ G aeway breaker included Fully integrated AC battery system.Includes six Helps prioritize essential appliances enclosure IQ G aeway breaker 1 0 A or 15 A rating G E/Siem ens/Eaton included field-replaceable IQ ED-BAT M broinverters. during a grid outage to optim ee energy 5-year lim ted warranty consum ption and prolong battery life. Production m Gering CT 200 A solid core pre-installed and w Led to IQ G aeway • 2-year labor reim blrsem ant program coverage included for both the C msum ption m mitoring CT(CT-200-C LAM ) A pair of 200 A clam prstyle current transform es is included w th the box IQ C an liner SKUS IQ Battery m etering CT 200 A clam p-style current transform a for IQ Battery m Gering,included w th the box UL1741 Listed C&us FON LISTED 1. A plug-and-play industrial-grade cell m aiem for system sof up to 60 m broinverters.Available in the United States,C mada,M ecico,Puerto Rico,and the US Virgin Islands,w here there is adequate 5-year lim led cellular service in the installation area. warranty *For country-specific warranty inform aion,see the https://enphase.com Anstallers/resources/warranty page. ©2024 Enphase Energy.All rights reserved.Enphase,the a and C Clogos,IQ,and certain other m arks listed at https://enphase.com Rradem ak-usage-guidelines are tradem arks of Enphase Energy,Inc.in the U.S.and other countries. DRAWING NUMBER: Data subject to change. IQ C 6-5C-0SH-00007-3.0-EN-US-2024-03-01 IQ C 6-5C-0SH-00007-3.0-EN-US-2024-03-01 SS DATA Accessories Dim visions(W•H x D) 37.5 cm•49.5 cm•16.8 cm(14.75"•19.5"•6.63").Height is 21.06"(53.5 cm)w th m canting BLUE RAVEN SOLAR brackets Weight 7 .5 kg(16.5lbs) M obile C vtnect C Fcuit breakers Am bent tem perature range- 40GC to 46°C(-40°F to 115°F) 4G{based LTE-M Cellular m cdem w th a 5-Year BRK-10A-2-240V C tcuit breaker,2-pole,10 A,Eaton BR210 data plan BRK-15A-2-240V C tcuit breaker,2-pole,15 A,Eaton BR215 Cooling N atural convection,plus heat shield (C ELLM O OEM-M-106-SP-05 for Sprint and BRK-20A-2P-240V C tcuit breaker,2-pole,20 A,Eaton BR220 u Enclosure environm vital rating O tdoor,NRTL certified,NEM Atype 3R,polycarbonate construction C ELLM O OEM-M-D6-AT-05 for AT&T) BRK-15A-2P-24OV-B C tcuit breaker,2-pole, A,Eaton BR215B w th hold-dow nkit support 2 0 A to 50 A breaker inputs:14 to 4 AWG copper conductors BRK-2CA-2P-240V-B C tcuit breaker,2-pole,20 A,Eaton 6 0 A breaker branch input:4 to 1/0 AWG copper conductors BR220B w th hold-dow,nkit support Wire sizes W in lug com lined output:10 to 2/0 AWG copper conductors N eutral and ground:114 to l/0 copper conductors A Iways follow local code requirem efts for conductor sizing Com m unication(in-prem be connectivity) Built-in CTRL board for w ted com m unication w th IQ Battery 5P and IQ System C mtroller 3/3G. Integrated power line com m unication for IQ Series M broinverters CT-200-SO LJD CT-200-C LAM P Altitude U p to 2,600 m eters(8,530 feet) 200 A revenue-grade solid core Production CT 200 A clam p-style consum ption and battery r rN INTERFACES w th<0.5%error rate(replacem art SKU) m Bering CT w th<2.5%error rate(replacem ant Integrated Wi-Fi 8 02.11b/g/n(dual band 2.4 G Ft/5 G Ft),for connecting the Enphase C bud through the internet lop SKU) Wi-Fi range(recom m ended) 1 0 m(32.8 feet) Bluetooth B LE4.2,10 m range to configure W i-Fi SSID Ethernet O ptional,802.3,C 35E(or C 3 6)UTP Ethernet cable(not included),for connecting to the Enphase C bud through the internet Cellular/M c bile C mnect C ELLM O[EM-M-106-SP-05 or C ELLM O OEM-M-1D6-AT-05(included w th IQ C cm liner 5C) Digital I/O D igital input/output for grid operator control USB 2.0 M bile C mnect,C O M M'.KIT-01 for IQ Battery 3/3T/10/10T,C O M M'.KIT-02 for IQ Battery 5P Access point(AP)m ode F or connection between the IQ G deway and a m dbile device running the Enphase Installer App Metering ports U p to two C msum ption CTs,one IQ Battery CT,and one Production CT Power line com m inication 9 0-110 kHz Web API See https://developer-v4.enphase.com Local API See guide for local API r UL 1741,CAN/C S>C 72.2 No.107.1,Title 47 C FIR,Part 15,C hss B,IC B3 003,NO M 208-SC R-2016, IQ C an liner w th IQ G ateway UL 60601-1/CANC SA 22.2 No.61010-1,IEEE 1547:2018(UL 1741-SB,3rd Ed.),IEEE 2030.5/C SP C cm pliant,Production m etering:ANSI C 2.20 accuracy class 0.5(PV production) PV M icroinverters I Q f IQ7,and IQ 8Series M broinverters IQ System C mtroller E P20OG D1-M 210US00 CO M M EI(IT-012 IQ System C mtroller 2 E P20OG D1-M 210US01 IQ Battery E NC FARG E3-1P-NA,ENC HARG E-10-11P-NA,ENC FARG E3T-IP-NA,ENC FARG E10T-1P-NA IQ System C mtroller 3 S C 2)OD111C 210US01,SC 2)OG 11C L40US01 CO M M SKIT-02' IQ Battery I Q BATTERY-5P-lP-NA 2. For information about IQ C on finer 5/5C com ratibility w th the 2nd-generation batteries,refer to the compatibility matrix. DRAWING NUMBER: 3. IQ C an liner 5/5C com s pre-equipped w th C O M M SIT-02. IQ C 6-5C-0SH-00007-3.0-EN-US-2024-03-01 IQ C 6-5C-0SH-00007-3.0-EN-US-2024-03-01 SS Data Sheet Nor- BLUE RAVEN Enphase Networking03 N.Research i Enphase IQ Envoy 140iem,UT84097vay 800.377.4480 MODEL N U M HRS WWWBLUERAVENSOLAR.COM Enphase IQ Envoy'" Enphase IQ Envoy com m ulications gateway with integrated revenue grade PV CO N=IDENTIAL-THE INFO Rv1ATIO N ENV-IQ-AM 1-240 production HEREIN CO NfAINED SHALL NO TBE metering(ANSI C12.20+/-0.5 i)and optional consumption monitoring(+/-2.5%). USED FO RTHE BENEFIT O FANYO NE Includes EXCEPT BLUE RAVEN SO LAR NO R Enphase IQ Envoy M SHALL ITBETO 0IfgS0UrSI LEOR The Enphase IQ Envoy com m Lnications gateway one 200A continuous rated production CT(current transformer). IN PART DI OIHSED O IN WHO L delivers solar productionand ener9Y consumption ACCESO RES(Order Seperately) RECIPIENTS 0 R G NIZATIO N EXCEPT IN CO MIECTIO NWITH THE SALE AND Enphase Mobile Connect'' Plug and play industrial grade cellular m odem with data plan for system s up to 60 USE O FTHE RESPECTIVE EQ UPM ENT, data to Enphase Enlighten'M monitoring and analysis CELLM ODEM-M 1(4G based LTE-M/5-year data plan) m Icroinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin WITHO Ur THE WRITTEN PERM ISSIO N software for comprehensive,rem ote m aintenance and CELLM ODEM-M 1-13(4G-based LTE-M 1/5-year data plan) Islands,where there is adequate cellular service in the installation area.) O FBLUE RAVEN SO LAR LLC. Consumption Monitoring CT Split-core consumption CTs enable whole hom e m etering. management of the Enphase IQ System. CT-200-SPLIT Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge'"storage NABCEP COM M SKIT-01 and Enphase Enpower"smart switch.Includes USB cable for connection to IQ CERTIFIED] W th integrated revenue grade production metering Envoy or Enphase IQ Combiner'"and allows wireless com m unication with Encharge and Enpower. and optional consumption monitoring, Envoy IQ is the POWER REQUIREMENTS PV INSTALLATIO N PRO IESSIO N4L platform for total energy m anagem ent and integrates Power requirements 120/240 VAC split-phase. Scott G rrney Max 20 A overcurrent protection required. #PV-011719-015866 with the Enphase Ensem bleTmand the Enphase IQ Typical Power Consumption 5W BatteryTM. CA PACITY CO WRACTO R Numberofmicroinverterspolled U pto600 BRS FIELD O PS 385-498-6700 MECH ANICAL DATA Dimensions(W xHxD) 2 1.3 x 12.6 x 4.5 cm(8.4"x 5"x 1.8") Sm art Weight 17.6 oz(498 g) Enables w Eb-based monitoring Am bent temperature range - 40°to 65°C(-40°to 149°F) ENPHASE and control -40°to 46°C(-40°to 115*F)if installed in an enclosure Bidirectional com m uiications for Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMAtype 3R enclosure. remote upgrades Altitude T o 2000 meters(6,560 feet) •Supports power export lim iting and Production CT- Limited to 200A of continuous current/250A OCPD—72kW AC zeroexport applications Internal aperture measures 19.36m mto support 250M CM THWN conductors(max) UL2808 certified for revenue grade metering Consumption CT- For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84"x 0.96"(21.33m m x 24.38m m)to support Sim ple 3/0 THWN conductor Easy system configuration using UL2808 certified,for use at service entrance for services up to 250Vac • Enphase Installer Toolkit"mobile app INTERN ET CO NN ECTIO NOPTIO N S Flexible netw eking w th W i-Fi, Integrated Wi-Fi 802.11 b/g/n Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLM ODEM-M 1(4G)or CELLM ODEM-M 1-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable CO MPLIANCE Compliance UL 61010-1 Designed for installation indoors CAN/CSA C22.2 No.61010-1 or outdoors 47 CFR,Part 15,Class B,ICES 003 DRAWING BY: Five-year w aranty IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 Metering:ANSI C12.20 accuracy class 0.5(PV production only) PLO TDATE: PRO ECT NUM PER: E N P H AS E_ To learn more about Enphase offerings,visit enphase.com EN PHASE SHEET NAM E To learn m ore about Enphase offerings,visit enphase.com �./ �./ ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,and other trademarks or service names are the trade- SPEC SHEET marks of Enphase Energy,Inc.Data subject to change.06-30-2021 REVISION PAGENUMEER: ---- SS 11� BLUE RAVEN SOLAR 6.63 .62 DIA WIRING DIAGRAMS 168 16 .31 DIA FUSIBLE 8 13 A S -- B -- 0 TERMINAL LUGS AMPERES MAX. WIRE MIN. WIRE TYPE 14.88 1 1 .24 378 285 60 -#3 AWG I#14 AWG I CU OR AL 0 KNOCKOUTS SYMBOL CONDUIT SIZE DIAMETER A,B,C IN MM IN MM KNOCKOUTS A,B,C A .50 13 .88 22 KNOCKOUTS B .75 19 1.13 29 C 1.00 25 1.38 35 D 1.2S 32 1.75 45 1 .64 42 3.76 4.87 96 124 .31 DIA 8 7.45 (2 HOLES) 189 NEMA TYPE 3R A,B,C,D KNOCKOUTS r^ ^,�) A KNOCKOUTS DUAL DIMENSIONS: INCHES MILLIMETERS .28 DIA KNOCKOUT A,B,C HORSEPOWER RATINGS NOTES: 7 KNOCKOUTS VOLTAGE RATINGS CATALOG NUMBER WIRING AMPERE 240VAC DIAG. RATING FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITED OVER CLEANED PHOSPHATIZED STEEL STD. MAX. UL LISTED - FILE E-2875 1 0F7.50 1 0 3 0 ALL NEUTRALS - INSULATED GROUNDABLE SUITABLE FOR USE AS SERVICE EQUIPMENT D222NRB 240VAC A 60 3 10 15• SHORT CIRCUIT RATINGS: D322NRB 240VAC B 60 3 �E 10 15 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES TOP ON NEMA 3R ENCLOSURES HAVE PROVISIONS FOR MAXIMIM 2.50 BOLT-ON HUBS. WHEN MOUNTING THESE SWITCHES, ALLOW 3.00 IN / 76 MM MIN. CLEARANCE BETWEEN ENCLOSURES FOR OPENING OF SIDE HINGED DOOR. GENERAL DUTY SAFETY SWITCHES SQUARE O COMPANY X USE OUTER SWITCHING POLES VISIBLE BLADE TYPE mo •FOR CORNER GROUNDED DELTA SYSTEMS ONLY. 60 AMPERE LUGS SUITABLE FOR 60°C OR 75°C CONDUCTORS. ENCLOSURE - NEMA TYPE 3R RAINPROOF NO. 863 JUNE 2000 REF DWG #1863 DRAWING NUMBER: ss JB- 1 . 2 , JB- 1 .XL EZf SOLAR PHONE:385-202-4150 Specification Sheet making solar simple. WWW.EZSOLARPRODUCTS.COM BLUE RAVEN making solar simple, PV Junction Box for Com position/Asphalt Shingle Roofs SOLAR A. System Specifications and Ratings ITEM N0. PART NUMBER D ESCRIPTION 0 TY sizE DWG.NO, R EU • A/I ximum Voltage: 1,000 Volts 1 1 JB-1.2 BODY POLYCARBONATE B J B-1.2 WITH UV INHIBITORS SCALE:1:2 EIGHT:1.45 LBS HEET I OF 3 • W ximum Current: JB-1.2: 80 Am ps; JB-1.XL: 120 Am ps • A Ilowable Wire: 14 AWG—6 AWG POLYCARBONATE 2 JB-12 LID WITH UV INHIBITORS 1 TORQUE SPECIFICATION: 15'2D LBS • S pacing: Please maintain a spacing of at least '/2"between uninsulated live parts and fittings for c onduit, arm cred cable, and uninsulated live parts of opposite polarity. 3 #10 X 1-1/4"PHILLIPS 6 CERTIFICATION: UL 1741,NEMA 311 • E nclosure Rating: Type 3R PAN HEAD SCREW GSA C22.2 NO.290 • R oof Slope Range: 2.5 — 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS • M x Side Wall Fitting Size: 1" PAN HEAD SCREW • M x Floor Pass-Through Fitting Size: 1" • A m bent O pzrating Conditions: (-35°C) - (+75°C) • C om pliance: - JB-1.2: UL1741, CSA C22.2 No. 290; J13-1.XL: UL1741, CSA C22.2 No. 290 off-Approved wire connectors: m ust conform to UL1741, CSA C22.2 No. 290 • S ystem M eking: Interek Sym bol and File#5019942 5019942 \� • P eriodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion b etween corn ponents, com ponents that are found to be affected are to be replaced im m(diately. Table 1:Typical Wire Size,Torque Loads and Ratings 1 Conductor 2 Conductor Torque Type IN MI nch Lbs I oltage C urrent ABB ZS6 term hal block 10-24 awg 1 6-24 awg S of/Str 0 .5-0.7 6 6.2-8.85 OOV 0 am p ABB ZS10 term hal block 6-24 awg 1 2-20 awg S of/Str 1 .0-1.6 8.85-14.16 OOV 0 am ABB ZS16 term hal block 4-24 awg 1 0-20 awg S of/Str 1 .6-2.4 14.6-21.24 OOV 0 am p 27 1.01 in � 27 0.88in � 'S 1 1.01 in 10.88in ABB M 6(8 term hal block 8-22 awg S of/Str 08-1 6 8.85 OOV 0 am p Ideal 452 Red w,'.'1-a, 8-18 awg S of/Str Self-Torque Self-Torque 600V SOLAR Ideal451 Yellow wre�o ate, 10-18awg S of/Str Self-Torque Self-Torque 600V Ili Ai Ideal, In-Sure p��yC.nneclor 10-14 awg S of/Str Self-Torque Self-Torque 600V WAG O 2204-1201 10-20 awg 1 6-24 awg S of/Str Self-Torque Self-Torque 00V3 0 amp Ili J111`1.2 WAG O 221-612 10-20 awg 1 0-24 awg S of/Str Seff-Torque Self-Torque OOV 0 amp Dottie DRC75 6-12 awg S of/Str Snap-In S nap-In l I Patents:e 1,,pr uc.c /patents ESP NG-63 4-6 awg S of/Str 45 2000V , 10-14 awg S of/Str 35 ESP NG 717 4-6 awg S of/Str 45 a 200oV --- - 10-14 awg S of/Str 35 Brum all 4-5,3 4-6 awg S of/Str 45 2000V 10-14 awg S of/Str 35 [183.06mm] J2.53mm 7.21 in 2.86in Table 2:M him u mwire-bending space for conductors through a wall opposite term pals in m m(inches) [265.18mm] 10.44in Wires per terminal(pole) Wire size,AWG or 1 2 3 or Mae kcm I (m m 2) m m (inch) m m (inch) m m (inch) m m (inch) 14-10 (2.1-5.3) Not Specified 8 (8.4) 38.1 (1-1/2) 6 (13.3) 1 50.8 (2) - - - PROPRIETARY AND CONFIDENTIAL:THE INFORM/YIONCONTAINEDINTHIS DRAWING ISTHESOLEPROPERTYOFEZSOLAR. ' DRAWING NUMBER: ANY REPRODUCTION IN PART OR AS A W HOLE W IrHOUTTHE W RTTEN PERM 6SION OF EZ SOLAR IS PROHIBITED. 50157M EZ*SOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM SS ISSUE DATE: ISSUE DATE: BLUE RAVEN NOW- RIG D PVC CONDUIT FITTINGS DATE D'EM BSIO Nt 2909 04 30 RIG D PVC CONDUIT FITTINGS DATE D'EM BSIO Nt 2909 04 30 SOLAR SUPERCEDES: SUPERCEDES: JB444 JUNCTIO NBO )F-S 2 REM PLACE: 004 07 15 JB444 JUNCTIO NBO )(ES 2 REM PLACE: 004 07 15 5 - COVER DIM ENSIO N6 4.010" (102mm ) B AC E 4.010" (102m m ==J—) 'Z c �I B D PRO DJCT PART NO MMAL SIZE A B C CO CE NUMBER (in) (mm) (in) (mm) (in) (mm) (in) I (mm) 0.245" 076668 J444 STAHLIN 4 1 03 3 .675 9 3 4 .000 1 02 3 .450 8 8 076259 AM JB444 ALLIED 4 1 03 3 .675 9 3 4 .000 1 02 3 .450 8 8 077643* 2037-424T CANLET 4 1 03 3 .675 9 3 4 .000 1 02 3 .450 8 8 (6 m m ) 077696 JB 444 4 1 03 4 .000 1 01 4 .395 1 12 3 .950 1 01 PRO DJCT PART NO MMAL SIZE I D I E VO WM E 0.190" D A CO CE NUMBER (in) (mm) I (in) I (mm) I (in) I (mm) I (cu. Cm) 076668 J444 STAHLIN 4 1 03 4 .180 1 06. 3 .850 9 8 5 1.5 8 44.6 076259 AM JB444 ALLIED 4 1 03 4 .180 1 06 3 .850 9 8 5 1.5 8 44.6 077643* 2037-424T CANLET 4 1 03 4 .180 1 06 3 .850 9 8 5 1.5 8 44.6 0. o"077696 JB 444 4 1 03 4 .170 1 06 3 .930 1 00 5 1.5 8 44.6 � 0.25 PRO DJCT PART NO M MAL SIZE GASKET INSERT SCREW M FEET CO CE NUM BER (in) (mm) CO CE CO CE CO CE CO CE Sm dl Mounting Feet 076668 J444 STAHLIN 4 1 03 0 72538(4) 1.970" Product C ode 097747 076259 AM JB444 ALLIED 4 1 03 0 72538(4) 077643* 2037-424T CANLET 4 1 03 0 72538(4) 0.175" 077696 JB 444 4 1 03 0 97731 072538(4) 072522 (4) 0 97747 072539(2) 072513(2) BOX WITH MOLDED MOUNTING FEET,INSERT ONLY;NO COVER,OR GASKET,UL LISTED 576J DRAWING NUMBER: Page: CO f�DUIT—41.1 Page: CO f�DUIT—41. 11� BLUE RAVEN SOLAR Connected" =YC r ' r r pDrients H eyco®-T ie Liquid T& C ardgrips for Enphase Q C kles Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Utim ite in Liquid Tight Strain Relief Protection `�PRODUCT! GLAND P ART NO. ESCRIPTION P ART DIM INSIONS •Two new cordgrips now accom m date D c B CONFIGURATION A ©/JR the Enphase 0 Cable—M T31 GCZ conductors o r learance Mex.O.A. ThreadrW enching Nut (1/2""NPT)and M 3234GDA-SM Type Size N o. B lack H 911�5 ole Dia. L ength ength Thickness Flat Size (3/4""N PT). m M. in. m .n.i I m .n.il m m. ni I mJI.n.i m m. Oval Gland •The 1/2-version provides liquid tight Q Cable 16,1 x 9,711 N111 231GCZ L I TCG 1/2 6.1x9.7M M I @/@ 1 875122,211.701 43,21.61 115,51.2115,3I. 98124,9 entry for one Enphase 0 Cable— Break-Thru Skinned Over Gland .24 x.38""(6,1 x 9,7 mm) 0 Cables II •The 3/4-version provides liquid tight plus 6,1 x9,7 2 M3234GDA-SM SMCG 3/4 2 6.1x9.7MM /��040 26,4 2.00�50,8.62 15,7 .25 6,4 1.30 33,0 entry for up to two Enphase 0 Cables— Ground 3,3 1 1-3.3MM II .24 X.38"(6,1 X 9,7 mm)and an M dal Locknuts INCLUDED. B additional.130"(3,3 mm)dia.hole for c a#8 solid grounding cable. 'I D FA The 3/4-version utilizes our skinned- -- -- over technology so any unused holes will retain a liquid tight seal. i •Rated for use with DG Cable. SUGGESTED CLEARANCE HOLE SEALING NUTJ 71NTEGRAL FOR NONTHREADED M WNTING SEALING RING M Serial Nylon 6/6 with TPE Sealing Gland Certifications L © isted under Underwriters'Laboratories File E504900 &P CSA Certified by the Canadian Standards Association File 93876 Flamm hility Rating 9 4V-2 Tem perature Range S tatic -40oF(-40oC)to 239°F(115°C) Dynam c-4°F(-20oC)to 212°F(1 DOT) IP Rating IP 68 BALL NEW H eyco®H elios® U VX C 1p - Blind Mount PRODUCT! PANEL THICKNESS RANGE W RE DIAM ErER P ART NO. D ESCRIPTION M UNTING OVERALL •The jersey pine tree mounting style RANGE H 0LE DIA. H EIGHT installs easily with superior holding M him ua M AM tm 1 -2 W Tres A power. in. � m. ri. I mm. n.i i m m. n.i i m m. .UVX nylon protects from corrosion due 1-2 W'res to outdoor exposure. 23(5,8 m m}.32(8,0 m m -S6520 elios UVX Clip 100 Pack 028 7 . 250 4 each cable S6560 elios UVX Clip Bulk 260 6 ,6 96 �44, Installs into.260""(6,6 m m)Tt writing hole. •Holds up to 2 cables between .230- ' .315""(5,8-8,0 m m Pach. •Cables install with fingertip pressure. c . A •M dded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our Solar 20 Year W aranty. M aerial N ylon 6/6 with extended UV Capabilities Flamm hility Rating 9 4V-2 Tem Ierature Range D ynam b -4°F(-20°C)to 185°F(85'C) 1. DRAWING NUMBER: 1-800-526-4182•732-286-1800(NJ)•FAX:732-244-8843•www.heyco.com 1-4` Sis 11� BLUE RAVEN o SOLAR SFM INFINITY v ::OUNIRAC r BETTER SOLAR STARTS HERE MEW BONDING&GROUNDING © 7 CHANICAL LOADING UL2 O3 SESTEMFRE CLASSIFICATION SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PART NAME D ESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY ff TRIMRAIL S tructural front trim provides aesthetic and aligns modules. I Make two installs per day your new standard.SFM INFINITY has fewer , roof attachments,one tool installation,and pre-assembled components TRIMRAIL SPLICE C onnects and electrically bonds sections of TRIMRAIL. E I to get you off the roof 40%faster. TRIMRAIL FLASHKIT A ttaches TRIMRAIL to roof.Available for comp shingle or tile. SFM INFINITY 15 Attachments ' MODULE CLIPS S ecure modules to TRIMRAIL. MICRORAIL C onnects modules to SLIDERS.Provides post-install array leveling. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. with integrated front trim,trim end caps,dark components,and ATTACHED SPLICE also available. recessed hardware. SLIDER FLASHKIT R oaf attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density With fewer SKUs and compact components,SFM INFINITY is easier to without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES attachments required by rail. stock,easier to transport,and easier to lift to the roof.Plus,make more PART NAME D ESCRIPTION efficient use of your vehicle fleet. TRIMRAIL ENDCAPS C avers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP E Iectrically bonds TRIMRAIL and modules O l N/S BONDING CLAMP E Iectrically bonds rows of modules • • • • SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR BENEFITS ACROSS YOUR BUSINESS , FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION 1 ' AND SERVICE. DRAWING NUMBER: SS I I I *1� SUN i BLUE RAVEN SYSTEM BONDING & GROUNDING 9 SOLAR mr FRAME me_____ -__S-FM -MICRORAILTM INSTALLATION P A G-E -GUIDE- 'I- E-W BONDING PATH: E-W m odule to m odule bonding is accom plished with 2 pre-installed bonding pins which engage on the secure side of the M brorailTM and splice. I I Star Washer is W EEBLUG Single Use Only Single Use Only Alternate m Ethod N-S BONDING PATH: TERM NALTORQUE, N-S m odule to m odule bonding is Install Conductor and accom pushed with bonding clam pwith 2 integral torque to the following: TERM NALTORQUE, TERM NALTORQUE, bonding pins. (refer also to alternate m ethod) 4-6 AW Cc 35in-lbs Install Conductor and Install Conductor and 8 AW Q 25 in-lbs torque to the following: torque to the following: 10-14 AW Cc 20 in-lbs 4-14 AW Ck 35in-lbs 6-14 AW a 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO-� Rsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley W EEBLug (6.7) • 10-32 m cunting hardware • 1 /4" m cunting hardware • 1 /4" m cunting hardware • T orque = 5 ft-lb • T orque = 75 in-lb • T orque = 10 ft-lb Alternate m Ethod • A W G4-14-Solid or Stranded • A W G4-14-Solid or Stranded • A W G6-14-Solid or Stranded TRIM PAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUM NUM CONTACT TO PREVENT CORROSION Trim rail to m odule bonding is accom pushed with System bonding is accom dished through m adules.System grounding accom Aished by attaching bonding clam pwith integral bonding pin and a ground lug to any m adule at a location on the m adule specified by the m adule m mufacturer. bonding T-bolt. (refer also to alternate m shod) DRAWING NUMBER: SS Nor- BLUE��N RAVEN UL CODE COMPLIANCE NOTESZ 0 SOLAR on SFM FRAME ME MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the m amner specified in the perform ance is inherent in the SFM design,and no additional m Ligation m (Bsures SUNFRAM EM CRORAIL (SFM )Installation Guide. SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required m him u mor m acim u mheight Lim Cation above the roof deck to m antain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM .SUNFRAM EM CRORAILT"com ponents shall B & C system level perform aice for low slope & steep sloped roofs when used be m canted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 m odules. Class A, B & C system level fire Module Type R I oof Slope S i ystem Level Fire Raking M crorail Directiom M dule Orientation M tigation Required Type 1 and Type 2 S teep Slope & Low Slope C lass A, B & C E ast-W Est L andscape OR Portrait N one Required UL2703 TEST M CDULES See pages 22 and 23 for a list of m odules that were electrically and m a:hanically tested or qualified with the SUNFRAM EM ICRORAIL (SFM )com ponents outlined within this Installation Guide. • M a(im u mArea of M odule = 27.76 sqft • UL2703 Design Load Ratings: a) D ownward Pressure - 113 PSF / 5400 Pa b) U pward Pressure - 50 PSF / 2400 Pa c) D own-Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) D ownward Pressure - 170 PSF / 8000 Pa b) U pward Pressure - 75 PSF / 3500 Pa c) D own-Slope Load - 32.4 PSF / 1550 Pa • M a(im u mSpan = 6ft • Use with a m a<im u mover current protection device OCPD of 30A • System conform sto UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • P V m odules m air have a reduced load rating, independent of the SFM load rating. Please consult the PV m odule m anufacturer's installation guide for m are inform anon • D own-Slope design load rating of 30 PSF/ 1400 Pa for m odule areas of 22.3 sq ft or less DRAWING NUMBER: SS SUN i BLUE RAVEN TESTED / CERTIFIED MODULE LISTl 22 SOLAR OEM IS FRAME ■ ■ F M MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ M anufacture M odule M adel/Series M aiufacture M odule M oriel/Series Manufacture M odule M adel/Series Aleo P -Series Eco Solargy 0 rion 1000 &Apollo 1000 LGxxxN2T-A4 ET Solar E T-M 672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ DNA-120-(BF/M Fj26 Aptos Freedom Forever F F-M RBBB-370 01C/01K/S1C/S2W}A5 DNA-144-(BF/M Ij26 FreeVolt M ono PERC LGxxxN2T-B5 LGxxxN1K-B6 CHSM 6612P,CHSM 6612P/HV,CHSM 6612M, GCL G CL-P6 & GCL-M 6Series LGxxx(A1C/M 1C/M 1K/N1C/N1K/01C/01K/ Astronergy CHSM 6612M,HV,CHSM 6610M (BL)(BF)/(HF), Hansol TD-AN3,TD-AN4, LG Electronics OAC/OAK)-A6 CHSM 72M IC — UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W}E6 Auxin AXN6M 610T,AXN6P610T, 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W}G4 AXN6M 612T&AXN6P612T Heliene 144HC M 6M mofacial/Bifacial Series, LGxxxN2T-J5 AXlblackprem um 60(35m m) 144HC M 90 SL Bifacial LGxxx(N1K/N1W/12T/N2W}L5 AXlpower 60(35m m) HT Solar HT60-156(M)(NDV) (-F), LGxxx(N1C/01C/01K)-N5 Axitec AXlpower 72 (40m m) HT 72-156(M R) LGxxx(N1C/N1K/N2WiQ1C/01K)-V5 AXlprem ium 60(35m m) Hyundai KG,M GTG,RI,RG,TI,M(HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM AXlprem ium 72 (40m m) HiA-SxxxHG LR4-72(HIH/HPH)-xxxM Boviet BVM 6610, ITEK i T,iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30m m) BVM 6612 Japan Solar J PS-60 &JPS-72 Series LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35m m) — BYD P 6K & M H<-36 Series LCNGi LR6-60(BK)(PE)(PB)(PH)-xxxM (40m m) JAP6 60-xxx,JAM 6-60-xxx/SI,JAM OK)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30m m) CS1(H/K/U/Y) M S xxx,JAP6 k-72-xxx/4BB,JAP72SYY-xxx/ZZ, ( )( )( )( )( )( ) CS3(K/L/U),CS3K-M SAG,CS3K-(M$�P) ( ) LR6-72 HV BK PE PH PB HPH -xxxM Canadian Solar CS3N-M$CS3U-M B-AG,CS3U-(M$lP),CS3W JAP6(k)-60-xxx/4BB,JAP60SYY-xxx/ZZ, (35m m) CSSA-M,CS6(K/U),CS6K-(M/P),CS6K-M S JA Solar JAM 6(k)-72-xxx/ZZ,JAM 72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40m m) CS6P-(M,P),CS6U-(M iP),CS6V-M,CS6X-P JAM 6(k)-60-xxx/ZZ,JAM 60SYY-xxx/ZZ. M 6sion Solar Energy M SE Series i.YY:01,02,03,09,10 Centrosolar Am Erica C -Series & E-Series ii.ZZ:SC,PR,BP,HiT,IB,M W M R M tsubishi M JE & M LE Series CT2xxM xx-01,CT2xxPxx-01, JKM &JKM SSeries Neo Solar Power Co. D 6M & D6P Series CertainTeed CTxxxM)o(-02,CTxxxM-03, CTxxxM)x-04,CTxxxHC11-04 Jinko Eagle JKM)xxM JKM xxxM 72HL-V Dehui D H-60M FKyocera K U Series • Unless otherwise noted,all m odules listed above include all wattages and specific m odels within that series. Variable wattages are represented as "xxx" • Item sin parenthesis are those that m ay or m air not be present in a com patible m odule's m odel ID • Slashes 7" between one or m Ere item sindicates that either of those item sm air be the one that is present in a m odule's m cdeL ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar m odule selected is approved for use with SFM • SFM Infinity is not com patible with m odule fram eheight of less than 30m mand m a-e than 40m m .See M odule M aunting section, page 12 for further information DRAWING NUMBER: SS SUN i BLUE RAVEN TESTED / CERTIFIED MODULE LIST1 23 SOLAR OEM IS FRAME ■ ■ F M MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ M a ufacture M odule M odel/Series Manufacture M odule M odel/Series Manufacture M odule M odel/Series EVPVxxx(H/K/PK), TwinPeak Series V Suniva M Series & Optim LE;Series VBHNxxxSA15 & SA16, TwinPeak 2 Series A-Series A400-BLK,SPR-M AX3-XXX-R, SunPower VBHNxxxSA17 & SA18, REC Solar(cont.) TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M Y2(XV) Suntech S TP,STPXXXS-B60/W rhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38m m) TP572,TP596,TP654,TP660, VBHNxxxZA01,VBHNxxxZA02, TP4(Black) Talesun TP672,Hipor M,Sm at VBHNxxxZA03,VBHNxxxZA04 Renesola V itrus2 Series & 156 Series SC,SC B,SC B1,SC B2 Peim ar S GxxxM FB BF Risen R SM 72-6 M DG M RSM EO-6 Tesla ( / ) ( ) ( ) TxxxH,TxxxS Phono Solar P S-60,PS-72 SEG Solar SEG-xxx-BM allV PA05,PD05,DD05,DE06,DD06,PE06, Prism Solar P 72 Series SEG-xxx-BM aTB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy S N72 & SN60 Series(40m m) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim S EG-6 & SRP-6 Series UP-M xxxP(-B), O.PEAK DUO BLK-G6+ Upsolar Sharp N U-SA& NU-SC Series � UP-M)ocxM(B) O.PEAK DUO BLK-G6+/TS Silfab BLK -G8 SLA, SLG,BC Series & SlLxxx(BL/NL/NT/HL/ D7M)xxH7A,D7(M/K)xxxH8A O.PEAK DUO + ( ) ( ) M VB K/N X/N U/H C) United Renewable Energy FAKxxx(C8G/E8G),FAM x(xE7G-BB O.Cells O.PEAK DUO L-G8.3/BFF Solarever USA S E-166*83-xxxM 120N (URE) FAM)xxE8G(-BB) O.PEAK DUO(BLK) M L-G9(+) FBM)xxM FG-BB PowerXT-xxxR-(AC/P D/B D) O.PEAK DUO XL-G9/G9.2/G9.3 Eldora, Solaria PowerXT-xxxC-PD O.PEAK DUO(BLK) M L-G10(+) PowerXT-xxxR-PM (AC) Vikram Solivo, O.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Som Era O.PEAK DUO BLK M L-G10+/t SolarW a-ld Sunm odule Protect, Sunm odule Plus W mree A C&Adiya Series Alpha (72) (Black)(Pure) SS-M 360 to 390 Series, W i-laico W ST&W SP Series RECxxxAA PURE-R RECxxxNP3 Black SS-M 390 to 400 Series, Yingli Y GE &YLM Series N-Peak(Black) Sonali SS-M 440 to 460 Series, ZN Shine Z XM 6-72, ZXM 6-NH144-166 2094 - REC Solar N-Peak 2 (Black) SS-M 430 to 460 BiFacial Series, SS 230-265 PEAK Energy Series PEAK Energy BLK2 Series SunEdison F -Series,R-Series & FLEX FXS Series PEAK Energy 72 Series • Unless otherwise noted,all m odules listed above include all wattages and specific m odels within that series. Variable wattages are represented as "xxx" • Item sin parenthesis are those that m aj or m air not be present in a com patible m odule's m odel ID • Slashes "/" between one or m cre item sindicates that either of those item sm air be the one that is present in a m odule's m odel ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar m odule selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not com patible with m odule fram eheight of less than 30m mand m cre than 40m m .See M odule M cunting section, page 12 for further inform a ion SS NOW- BLUEtntertek tertek RAVEN AUTHORIZATION TO MARK AUTHORIZATION TO MARK SOLAR Total Quality.Assured. Total Quality,Assured This authonzes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report This document is the property of Intertek Testing Services and is not transferable The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark_ �epplied only at the location of the Party Authorized To Apply Mark, Applicant: Unirac, Inc Manufacturer: Applicant: Untrac, Inc Manufacturer: Address: 1411 Broadway Blvd NE Address: Address: 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Albuquerque, NM 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer /// Party Authorized To Apply Mark: Same as Manufacturer n Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest.CA y Report Issuing Office: Intertek Testing Services NA, Inc„ Lake Forest, CA ny Control Number: 5003705 Authorized b Ifs\ brew✓ y: ...e�y/ Control Number: 5014989 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C us C uS CO Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. 1Tks Aaffonzaeon b Krk rs for tlrs aWrMrrs uN d tnsryk's Cram errd a t>�tdad pr+uere b IM Cenlaraeort agearfwrt beteeen InlsrW arrd b C Ionl IMwlnk a recrgrxrprty aril axarty ere The AWIOnJahOn ID MOM.*for fe sapuwas u"of Inl~s Cane wd m fwtmdod p osunrl so the Csrlillk~arso of besnsen lrorts►en0 M Ctrsra lnlerlsa^►rM$' l i ty and aabilny are lmbd 10 VW Writ and CavlrhOre d fe apes"it InW*k awunw no Irbney 10 any"my.ofw than to no C"m M woad"we,ate ap oev w 1.la"loss.expense a damage 04iurred linsled b fe law and condbore d IV epnrwrwa kd~assumes no imbtty b any pry.o w fen to fe pins M accordance win 1ti 894M w Our wry loss.elpwrse or dome"occasional by the use ul Ors AuVwtzabon to Mark only the Cbwa is wrf4d ed lo law copying or daiYEr/bn of ha k0iontaso n to Mark and Oran oNy M As ererety.ues of InMdek's Cet%fl ib0 n k• by Ora urr a1 frs Aslwrzabon to Mark.Orgy 11e Grare is aWMnzed lo per"onpWV or daetGdari all INS Asir URbon to ksars wd fan orgy n m enbey.Use o1 bow It s Ceru6calion mark e rswrcted 10 0ra lAnWOM lad Ott In to sWeenwa and n ftis ALVcnzaaen to Mark A1ry k~use or We krlwsak rare far fe sale or adverh anvil of to 10OW mall",Irdr<1 a sa"re rnW reabxJW b"conOborn Lod as m"aQraeman[MW h frs Auhonzsson to Work.Any rufw was of brs InMrMk rwvm for are sale or ad.emwnrre of bra 1ssNd mslwwl,product or soar"mr%: fret be spot/sa n vmbrrp by a nsrlM-In"Factory Aeeewraeft and Fdbw up 5wvx"we to fe pupa"of saatrkq a- ,- , usepa o1 Ve CaWke iw+mrk n acwrdwxa,rem the firal beapprogd nae pbeIrlseIn"Fact"Ae"pnarae sro Follow W 5rsrvitea sn br fe ptrpaas of aseump a00ropnaM usage or fe Cw1ApMi0n mwk n saorllwru avdr tree ayeortrnl,VwV are not for are purposes at production grapy control aml do rot rows the Ctrwt of llrar aoepesom M tlra rsapsti agreenark"y are rot for the purposes of produrpon gefay con"and do rot rearm the Cliert of Mar oblpabons In ins respect Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,IL 60005 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, ClampinglRetention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, ClampingfRetention Devices, and Ground Lugs for Use with Flat- Standard(s): Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R.24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed 1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories(CSA TIL No.A-4020201 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:20201 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide. PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued: 17-May-2023 ED161.1611-JW201221M-1.nory ED163't�(I,1W202T1Merdalory DRAWING NUMBER: SS NOW- BLUE RAVEN tntertek tntczrtczk SOLAR AUTHORIZATION TO MARK AUTHORIZATION TO MARK Total Quality A:cilf0d Total Quality-Assurea. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shovvn below to the models described in the f'rouui-t,$) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report This authorization also applies to multiple Ilstee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple Ilstee model(s) identified on the correlation page of the Listinl, Report. Report. This document Is the property of Intertek Testing Services and is not transferable The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable- The certification mark(s) may bi applied only at the location of the Party Authorized To Apply Mark J applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: Address: 1411 Broadway Blvd NE Address: Address: 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Albuquerque, NM 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest.CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest,CA Control Number: 5019851 Authorized by: Er/ra' i Control Number: 5021866 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C us C ltS ,(OJT ,. Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. TW hAowlpn w lluv moot the eectuvve anti d e I* 'a Caere arho a pow mwit,"l 10 We Carifoaaon aprsarsre betwita i InI0 and as Coed MerekY M%ionbblity and Iebrity are Tn s AJt d ratio b Isrk s b lte daClurve uae d trite YkY Oyre sro n►povdM ptraiara b M Caaapaeon ap senrsrr betoW Inenak and ere Cyr/a MrIKY gIS" 14 1My MITI M10 ty are Irllbad b M Itirm and o"lpnw d the apreenisrit Inlaili k a mirmim no aabetr,to an'/party other,ran to/e Chia l in accordance wilt pre itiWoo 0 for Ny low e■puiw of dMnape occaocne0 limted to I»Wary and Oor1011ore of Ve apreenwnt Inerta►afeuneo no baba tr to am party ollm pen to We Client n scoordance r0+the aQerrent,for any Was.inv enu or damper ooWroriol a Ili fa»d k Afuplontalion to Mark Only the Glad is ndraued to perrnt oopyrg a dlrrauutn d fas AlNloncabon to Mirk and Von only 1n As enanty.Uae d In~*C-111maon mrk is br tie use a1 ws AurwltaYon b Mark Orgy/e Gntnrt is atdwnaed to parnc oopyrp or of It"Aulhortnbon to Mark and Fwr aYy in,b ermay.IAx d aerlak'a C4wicMon nwlt III f WnWd b ft OVANO r Wd a1 in wa aWwrtw!rrd In s s Auuwruaom to Mr1.Any further use d we InWOM mane for Wo aala or ad wlsMrtrll of We IsoW Wo W.product of sat+n mail rnao+tlad to IM mt.0 lad awl M h apnanwtt and in M Auftwealion to Mark Mr rur7w use d IM Ir erisk norm for IM fib or ad erbawr rut of ro eyed nra ,product or ump m. babe ap{aoesd in wilt bJ Yaerlea_In"Faci ry Amommenaf and Oration up Servitee are Id the papaw d astlaYg approp final be aWo- n ainbrg by Yar it"Fa ctory AOseertwiq and iebn to Sn•v m are for the propose of aasutrg apprOprele usage of l+e Cerofralm rrierk in amordenre riAM Rue apraaera t11//r•CAN Ior to purpors d pmdurnon o.war aonool and do not taleve r'Ciert aW tool dllpMons In Me orlati agrowevial.ley as not for We ptlrposm Of poduetim"Rf CW W and do rid r.I—rc Cirra o1 thw dblgebae in Me nbpect Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,It.60005 545 East Algonquin Road,Arlington Heights,IL W005 Telephone 800-345-3B51 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems. Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat- Standard(s): Standard(s): Plate Photovoltaic Modules and Panels JUL 2703:2015 Ed.1+R:24Mar2021J Plate Photovoltaic Modules and Panels JUL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No. A40:20201 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No, A-40:2020) Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide. PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide. PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued: 17-May-2023 FD1631511-Jul-2072)Mandaf,y ED1611511Jul-2NT%\tendavrr DRAWING NUMBER: SV 11� ntertek Listing Constructional Data Report (CDR) ntertek Listing Constructional Data Report (CDR) BLUE RAVEN Total Quality.Assured. Total Quality.Assured. LAR 1.0 Reference and Address 1.0 Reference and Address Report Num bar 102393982LAX-002 O n inal 11-A r-2016 R evised: 5-0 d-2022 Report Number 102393982LAX-002 O lioinal 11-A r-2016 R evised: 5-0 d-2022 M cunting System s, M cunting Devices, Clam Ong/Retention Devices, and G Dund Lugs for Use Ern al Standard(s) with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24M ar2021] PV M odule and Panel Racking M cunting System and Accessories [CSA TIL No. A-40:2020] Applicant M Unirac, Inc nufacturer 2 Address A 1411 Broadway Blvd NE ddress Albuquerque, NM 87102 Country C USA ountr Contact C Klaus Nicolaedis ontact Todd G anshaw 505-462-2190 Phone P 505-843-1418 hone FAX NA FAX Email E klaus.nicolaedis@unirac.com m ail toddg@unirac.com M anufacturer 3 anufacturer 4 Address A ddress Country C ountry Contact C ontact Phone P hone FAX FAX Ern ail E m ail M anufacturer 5 Address Country Contact Phone FAX Page 1 of 138 Page 2_of 138 This report is for the exclusive use of imeneKs Client and is provided pursuant to the agreement between Intertek and its Client Inlertek's respona.b",y aryl This report is for the OXCIU"e use of imertek'S Chent and is provided pursuant to the agreement between Intertek and its Client Inlertek's responsbgtyr and hapdty are limbed to the terms and conditions of the agreement Intertek assumes no habarty,to any party other than to the Client in accordance with the habisty are Ilrroted to the terms and conditions of the agreement Intertek assumes no liability to any party other than to the Client in accordance with the agreement.for any loss,expense or damage occasioned by the use of this report Only the Client is authorized to permit copying or distribution of the report an0 agreement for any loss,expense or damage occasioxd by the use of this report Only the Oient is authorized to permit wgicrg or distribution of the repot and then only in its entirety Any use of the Irifertek name or one of its marks for the sale or advertisement of the tested material. product or service must first be then only in its entirety Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material. product or service must first be DRAWING NUMBER: approved in wnt,ng by Intertek The observations and test results in this report are relevant only to the sannNe tested This report by itsell does not imply that the approved in writing by Intertek The observations and test results in this report are relevant only to the sample tested This report by itself does not imply that the material product,or service is or has ever been under an Intertek certification program material product,or service is or has ever been under an Intertek certification program Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-A r-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-A r-2016 Noor- Unirac,p 9 p p 9 p Inc Revised: 5-Od-2022 Unirac, Inc Revised: 5-Od-2022 BLUE RAVEN 2.0 Product Description 2.0 Product Description SOLAR Product Photovoltaic M cunting System,Sun Fram e M i;rorail Installation G dde, PUB2022SEP28 M odels Unirac SFM Brand name Unirac M odel Sim iarity NA The product covered by this report is the Sun Fram e M cro Rail roof m ounted Photovoltaic Rack M cunting System.This system is designed to provide bonding and grounding to Fuse Rating: 30A photovoltaic modules. The m ounting system ern ploys anodized or m it finish alum hum brackets that are roof m ounted using the slider, outlined in section 4 of this report. There are no rails M odule O Iientation: Portrait or Landscape within this product,whereas the 3" M cro Rail, Floating Splice, and 9"Attached Splice M adm um M odule Size: 17.98 ft2 electrically bond the m odules together form hg the path to ground. UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope The M cro Rails are installed onto the m odule fram a by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for M echanical Loading with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the m odules to the bracket. The bonding pin of the M cro Rail when bolted and torqued, penetrate Increased size M Ltest: the anodized coating of the photovoltaic m odule fram a(at bottom flange)to contact the m etal, M a(im urn M odule Size: 22.3 ft2 creating a bonded connection from module to module. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG 355S2W-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. National Electrical Code, including NEC 250: G Iounding and Bonding, and NEC 690: Solar M cunting configuration: Four m ountings on each long side of panel with the longest span of 24" Photovoltaic System s or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating:46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope revision in effect in the jurisdiction in which the project resides.Any local electrical codes m ust LG 335N2W-A5, be adhered in addition to the national electrical codes. The G rounding Lug is secured to the LG 380S2W-A5 and LG 355S2W-A5 used for used for Mechanical Loading test. photovoltaic m odule, torqued in accordance with the installation m anual provided in this M cunting configuration: Six m ountings for two m odules used with the m adm um span of 74.5" docum ent. IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift O tier optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings M echanical Load test to add FlashLoc Slider and Trim Assem blies to UL2703 and IEC 61646 which requires a m him urn of 2 m icro-inverters m ounted to the sam a rail, and using the sam e Certifications, & Increase SFM System UL2703 M odule Size: engage cable. M adrn urn Module Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G 5used for Mechanical Loading test. M cunting configuration: Four m ountings on each long side of panel with the longest span of 24" M an am um m odule size: 21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-CO UM LSD used for Mechanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 M odules. Can be installed at any interstitial gap. Installations m ust include Trim Rail. -Class A for Steep Slope Applications when using Type 2 M odules. Can be installed at any interstitial gap. Installations m ust include Trim Rail. -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5"gap between the bottom of the m odule and the roof's surface See section 7.0 illustractions# 1, 1 a and 1 b for a corn plete list of PV m odules evaluated with these racking system s O tier Ratings NA DRAWING NUMBER: ED 16.3.15(1-Jul-2022)Maidatory ED 16.3.15(1-Jul-2022)Maidatory S C RESIDENT IAL ROOFTOP SOLAR PERMIT PACKAGE Enphase = Platinum BLUE RAVEN � lowCITY OF ARLINGTON Installer ;0'_'J,R eileen beers BUILDING DEPARTMENT 1403 N 630 E APPROVED orem, Utah 84097 17322 84th Ave N E (800) 377-4480 PV Installation IDATEgy S U N PO W ER® BlueRavenSolar.com Professional Arlington, Washington 98223 Cecil n 4256980563 liOCHANCiESAL1THORIZED Authorized Dealer 11NLESS-APPROVED'BY THE IBUILDING'INSPECTOR SHEET INDEX p SCOPE OF WORK CL PV1 COVER SHEET CL INSTALLATION OF ROOFTOP MOUNTED PV2 SITE PLAN 'J PHOTOVOLTAIC SOLAR SYSTEM PV3 ROOF PLAN U PV4 STRUCTURAL N N PV5 ELECTRICAL 3-LINE PV6 ELECTRICAL CALCULATIONS Hula Q y PV7 LABELS I-. Z 3 PV8 PLACARD 0 — SS SPEC SHEETS > p Q C 0) U -c- L E_ '- 00 3 Q CL N 0 ' co p )- C DECEIVED �/ r - o U JUL 0 9 2024 Q N I. o .11a�.._--- W = 0 Zm p � U TYPICAL STRUCTURAL INFORMATION NEW PV SYSTEM INFORMATION TOTAL PV DC SYSTEM SIZE TOTAL PV AC SYSTEM SIZE t u a ROOF MATERIAL: Comp Shingle DC SYSTEM SIZE: 6.3 kW DC 6.300 kW DC 4.875 kW AC PROJECTID: SHEATHING: OSB AC SYSTEM SIZE: 4.875 kW AC 1002663 FRAMING: Manufactured Truss MODULE TYPE: 15 Silfab Solar SIL-420 QD �.. C DESIGN CRITERIA PVDC SYSTEM SIZE: RACKING: UNIRAC SFM INFINITY L ROOF ATTACHMENT: UNIRAC SFM INFINITY FLASHKIT INVERTER TYPE: (15) Enphase IQ8M-72-M-US �p4 rva5h �� WIND SPEED: 1 10 6.300 kW DC TOTAL ATTACHMENTS: 22 'C� �^� �� f!'. WIND EXPOSURE FACTOR: C PV AC SYSTEM SIZE: I RISK CATEGORY: II 4.875 kW AC 7 GROUND SNOW LOAD: 25 REVISIONS: GENERAL NOTES Sealed For ROOF SNOW LOAD: 25 �I �,,, -� 4056 � Existing Roof & SEISMIC DESIGN CATEGORY: D - �f.�. Gfsr �. WEATHER STATION DATA c0 -- Attachment Onl y F , sfoN'AL�C. WEATHER STATION: BOEING FLD KING CO Q -___ HIGH TEMP 2%AVG: 29°C 'DRAWN BY: 7/1/24 Digitally signed EXTREME MINIMUM TEMP: -70C Brendan Fillmore by John A. Calvert IPLOTDATE: AHJ Date: 2024.07.01 APPLICABLE CODES tune 29,2024 DRAWING TITLE: City o f Arlington W A 07:49:23 -06'00' *2023 NATIONAL ELECTRIC CODE(NEC) *2021 INTERNATIONAL BUILDING CODE(IBC) Cover Sheet *2021 INTERNATIONAL RESIDENTIAL CODE(IRC),2021 UNIFORM PLUMBING CODE(UPC),AND ALL STATE AND LOCAL BUILDING, ELECTRICAL,AND DRAWING NUMBER: UTILITY COMPANY PLUMBING CODES Snohomish County Public Utilities District (PUD) PV1 N%e BLUE RAVEN SOLnc 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com \ El KETH � U \ e Ei ® ® N N w cV is ® I w y w a Q i Z C \ Z O — > Q \ I LL } y � U O -0O I 00 0) 00 3 Q IL z N Sealed For Q) M c o >- CV) Existing Roof & o I 0 Attachment Only r U U I Q N \ rMSP J O \ CB + M / Cqj zC / �• j. a d cn 0 / PROJECT ID: i 460,56 1002663 PV DC SYSTEM SIZE: / S�O11AL E �' 6.300 kW DC PV AC SYSTEM SIZE: 711i24 4.875 kW AC REVISIONS: NEW 0 -_-_ PV SYSTEM A - A SITE PLAN Al SCALE: 1/16"= 1'-0" LEGEND PV SYSTEM SPECIFICATIONS COMPASS DRAWN BY: Brendan Fillmore BREAKER FIRE SETBACK TRENCH OR NEW PV SYSTEM INFORMATION N PLOT DATE: M UTILITY METER [BE] ENCLOSURE [BAT] ESS-BATTERY ❑ HATCH OVERHEAD PV MODULE: (15) Silfab Solar SIL-420 QD, POWER RATING: 420 W June 29, 2024 INVERTER: (15) Enphase IQ8M-72-M-US, POWER RATING: 325 W DRAWING TITLE: MSP MAIN SERVICE AC AC DISCONNECT ESC ESS -CONTROLLER MICROINVERTER i PROPERTY LINE PANEL W E Site Plan [SUB] SUBPANEL PV PV PRODUCTION RPO REMOTE POWER ROOFTOP DRAWING NUMBER: METER OFF SWITCH , JUNCTION BOX ICONS WITH DOTrED OUTLINE PV2 CT T CABIN UTILITY T R COMBINER BOX ATS GENERATOR INVERTER INDICATE INTERIOR LOCATION S BLUE RAVEN 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com 3' E d U L.- N N CN 00 U) LU 0" ® i Z C N LLw O O C —_ L > C3) O ® 0 0' • _ 4) °0 Q IL 04 4- LL CV O 0 o :�� r 0) U O MP1 Z U MODULE QTY: 15 1 T 0 N AZIMUTH: 272 ry- 0 PITCH:27I I \j LL O TSRF:83 i OC AREA:898 ft2 _ �"� ►�' '4 j�� a N Sealed For 3 Existing Roof & � Attachment Only �f � PROJECT ID: 4056 1002663 PV DC SYSTEM SIZE: 6.300 kW DC J� PV AC SYSTEM SIZE: 4.875 kW AC 7/1/24 MSP I POINT OF INTERCONNECTION REVISIONS: CB AC M NEW UNDERGROUND SERVICE LINE El PV SYSTEM 0 ROOF PLAN A SCALE: 1/8"= 1'-0" A LEGEND PV SYSTEM SPECIFICATIONS COMPASS DRAWN BY: Brendan Fillmore BREAKER FIRE SETBACK TRENCH OR NEW PV SYSTEM INFORMATION N PLOT DATE. M UTILITY METER BAT ESS-BATTERY HATCH OVERHEAD PV MODULE: (15) Silfab Solar SIL-420 QD, POWER RATING: 420 W June 29, 2024 FBE] ENCLOSURE DRAWING TITLE: MAIN SERVICE � � INVERTER: (15) Enphase IQ8M-72-M-US, POWER RATING: 325 W I- IMSP PANEL AC AC DISCONNECT [ES ESS-CONTROLLER MICROINVERTER PROPERTY LINE E Roof Plan W SUB SUBPANEL nPV METER OFF SWITCH JUNCTION BOX PV PRODUCTION REMOTE POWER ROOF TOP DRAWING NUMBER: FSUB] SUBPANEL ICONS WITH DOTTED OUTLINE7—'4:Q UTILITY METER GENERATOR V �\ , CT CT CABINET CB COMBINER BOX ATS ATS PANELL INV INVERTER INDICATE INTERIOR LOCATION S CEILING JOIST/ MAXIMUM MAXIMUM TOTAL PV ARRAY AREA H' 314,99 PANEL AZIMUTH PITCH TSRF AREA ROOF MATERIAL SHEATHING TYPE FRAMING TYPE FRAMING SIZE PURLINS SIZE RACKING TYPE ATTACHMENTTYPE ATTACHMENT CANTILEVER - - '�%e 10TAL ROOF AREA(ft') 2804 COI�NT (DEG) (DEG) (�) (ft. AND SPACING AND SPACING SPACING(S) (C) DISTRIBUTED LOAD(psf) 2.2 MP1 15 272 27 83 898 Comp Shingle OSB Manufactured Truss 2X4 @ 24 in OC 2x4 fa 24 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72"L/48"P 24"L/16-P ROOF COVERAGE(%) 11.23 TOTAL PV ARRAY WEIGHT(Ibs) 694.5 BLUE RAVEN MP2 0 TOTAL PV ATTACHMENTS 22 L A MP3 0 POINT LOAD(Ibs/aH.) 1 31 6 M P4 0 MPS D 1403 N 630 E MP6 D Orem, Utah 84097 MP7 0 (800) 377-4480 MP8 0 Blue RavenSo ar.com N,P9 0 MPID 0 ATTACHMENT TYPE: PV MODULES SHALL NOT EXTEND J Unirac SFM Infinity ABOVE ROOF RIDGE LINE I D PV MODULE MAX CANTILEVER U PER TABLE ABOVE M A— (C) CV H UNIRAC UNIRAC N 0 PV MODULE SFM INFINITY SFM INFINITY 00 > 2"MICRORAIL 6.5"SPLICE L Z 3 V) _ ) } a) , O EXISTING FRAMING M U ROOF MATERIAL NOT -C N C_ SHOWN FOR CLARITY G L w � Q L 2Bz°MIN. N O I (1)5/16"LAG BOLT EMBEDMENT WITH EPDM WASHER O } 0) U o C: U ATTACHMENT SPACING L PER TABLE ABOVE Q N FRAMING SPACING O PER TABLE ABOVE 0 *THIS DETAIL IS NOT MEANT TO BE ATTACHMENT DETAIL 1 FRAMING DETAIL' EXTERIOR WALL AN EXACT REPRESENTATION OF 2 z OC SCALE: 1/2"= 1'-0 FRAMING OR PV MODULE LAYOUT SCALE: 1-1/2"= 1'-0" z d N a RIDGE - NOTES o a LANDSCAPE PORTRAIT PROJECT ID: 1002663 PV DC SYSTEM SIZE: 6.300 kW DC PV AC SYSTEM S17E. 4.875 kW AC REVISIONS: A ---- Sealed For 0 Existing Roof & Attachment Only OV. DRAWN BY: Brendan Fillmore `- PLOT DATE: June 29,2024 6 DRAWING TITLE: ✓�. C�j k' AL Structural FOLLOW ATTACHMENT SPACING IN TABLE ABOVE -- 7/1/24 DRAWING NUMBER: EAVE *ATTACHMENT PATTERN SHOULD BE PV4 ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE 3 SCALE: 1/4"= 1'-0'' NOTED IN ENGINEERING LETTER L1 (1) 6 AWG THHN/THWN-2 CU BLACK L1 (1) 10 AWG THHN/THWN•2 CU BLACK Ll (2) 10 AWG THHN/THWN-2 CU BLACK 3/4 INCH Ll (1) 10 AWG THHN/THWN-2 CU BLACK 3/41NC Ll (1) 12 AWG THHN/THWN-2 CU BLACK (1) 6 AWG THHN/THWN-2 CU RED L2 (1) 10 AWG THHN/THWN-2 CU RED L2 (2) 10 AWG THHN/THWN-2 CU RED EMT 2 G (1) 10AWGTHHN/THWN-2CU RED L2(1) 12AWGTHHN/THWN-2CU RED 1 51�2 N (1) 6 AWG THHN/THWN-2 CU WHITE 4 N (1) 10AWGTHHN/THWN-2CUWHITE 3 G (1) 10AWGTHHN/THWN-2CUGREEN G (1) lOAWGTHHN/THWNEISPER ITT G (1) 6AWGBARE,CU G (1) 10 AWG THHN/THWN-2 CU GREEN 'TYPE OF CABLE MAY BE SUBSTITUTED FOR USE IN 'TYPE NM(ROMEX)/UF CABLE IS PERMITTED FOR INTERIOR 3/4 INCH RMC or PVC Sch 80 Exterior3/4 INCH EMT Exterior CONDUIT WHERE NEC CODE PERMITS OR ATTIC RUNS AND SHALL BE USED WHEN NEC CODE PERMITS ENPHASE O-CABLE.2-WIRE,FREE AIR Exterior BLUE RAVEN 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com PRIMARY PV COMBINER BOX 0—PRIMARY STRUCTURE 15A O �A(15)PV MODULES AC DISCONNECT B 6 MICROINVERTERS SAFETY SWITCH (N)20A 0 1©I Utility Meter (E)200A Main Service Panel b0A FUSIBLE MODULES PV ARRAY 1 ( O ENVOY -------, r- 1 2 I I 1 EL (E)200A IN)20A I I I I } N PV CIRCUIT 2 1 U G — 7 MODULESi 1 M EL 1 L--J (—0110— (V H 30A N Q 00 (EL) FUSES LI nG-- H LU 0'- >Q NrNi I L Z C > } (EL) 5 G ---- ------------------------------------------------C' —1 O a > -- }O I SUPPLY SIDE TAP U (EL) I NEC 250.24(A) — —0110— BOND GROUNDS Q 1 AND NEUTRALS 00 Q D ( _ IL(EL) ' M O N e � 4 10) U O C— U G I _ Q -C _ rn e ------------------------------------ O UNDERGROUND SERVICE O 120/240 VAC,60 Hz -L O O '" a C 1 PHASE,3 WIRE N GENERAL NOTES ` Z. f U Utility Meter Number:67537407 o Supply side tap.Interior POI. + U a 1 , PROJECTID: LEGEND (E) EXISTING (PV) PV BREAKER 1002663 (N) NEW (FIB) FACTORY INSTALLED BREAKER PV DC SYSTEM SIZE: (EL) EXISTING LOADS SPD SURGE PROTECTIVE DEVICE 6.300 kW DC (RL) RELOCATED LOADS MI MECHANICAL INTERLOCK .ae11[aiia 30 WK C-10 Wk 1 om PV AC S SIZE: EQUIPMENT NOTES EQUIPMENT DESCRIPTIONS fV0 I 4.875 �� 4.875 kW AC O FINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER.MUST COMPLY WITH MAX I(&PV MODULE:Silfab Solar SIL-420 QD,420 W DC,UL 1703/UL 61730 COMPLIANT T REVISIONS: -- MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. g MICROINVERTER:ENPHASE IQ8M-72-M-US,325 W AC(0.325 kW),1 PHASE,UL 1741 COMPLIANT ref _ � A C ROOFTOP JUNCTION BOX:EZ SOLAR 0 JB-1.2 JUNCTION BOX 0 JUNCTION BOX:PVC 4 X 4 JUNCTION BOX QB 3O O PV COMBINER BOX:ENPHASE COMBINER 5(X-IQ-AMl-240-5) Q — O .SQUARE-D SAFTEY SWITCH 60A,2P,240VAC,FUSIBLE(D222NRB) © • ODRAWN BY: OI Brendan Fillmore OJ PLOT DATE: O (9) June 29,2024 L 6 AWG SOLID COPPER GEC TO BE IRREVERSIBLY SPLICED TO(E)GEC TO COMPLY WITH NEC DRAWING TITLE: OO 250.64(D)(1). N OTHER NOTES Electrical < GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. O 3-Line P, 10 DRAWING NUMBER: 11 R PV5 S ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. 12 T ELECTRICAL INFORMATION PV BREAKER BACKFEED CALCULATIONS DESIGN LOCATION BLUE RAVEN UTILITY ELECTRICAL SYSTEM NEC 705.12(B)—"l 20%RULE" AND TEMPERATURES I-Phase,3-Wire,60hz l2012GOV (BUSBAR RATING'120%)-OCPD RATING=AVAILABLE BACKFEED DATA SOURCE ASHRAE Weather Station Data NEW PV SYSTEM MAIN SERVICE SUBPANELI SUBPANEL2 STATE Washington 1403 N 630 E PANEL I CITY Arlington 1-Phase,3-Wire,60Hz, 1201240V BUSBAR RATING 200A —A A Orem, Utah 8 ZE 4.875kW AC WEATHER STATION BOEING FLD KING CO AC SYSTEM SI 1 ) PANEL OCPD RATING 200A --A f+ 800 377-4480 HIGH TEMP 2%AVG 29°C ` 1 DC SYSTEM SIZE 6.3kW DC AVAILABLE BACKFEED(120%RULE) 40A ##A ##A Blue RavenSolar.com PV MODULESEXTREME MINIMUM TEMP -7°C 30A 30A 30A QUANTITY 15 PV BREAKER RATING TYPE Silfab Solar SIL-420 QD "ESE CALCULATIONS ARE ONLY APPLICABLE IF PV)NIFRCONNECTION IS A LOAD SIDE BREAKER.*PV BREAKER MUST BE RATED LESS THAN OR EQUAL TO WATTAGE 420W DC AVAILABLE BACKFEED FOR CODE COMPLIANCE' MICROINVERTERS TYPE Frphose 108V,-72-%A.-US OUTPUT CURRENT 1.35A AC NOMINAL VOLTAGE 240V AC OUTPUT POWER 325W AC U (o WIRE SIZE SPECIFICATIONS 04 © ® 0 10 H Lu ao0` >Q MINIMUM CONDUCTOR AMPACITY 13.5A AC 13.5A AC 13.5A AC 25.31A AC 25.31 A AC --A AC —A AC —A AC --A AC ---A AC L Z C > CONDUCTOR MATERIAL CU CU Cu CU CU -- -- "' L. CONDUCTOR TYPE THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 -- — -- — — 0 CONDUCTOR SIZE 12 AWG 10 AWG 10 AWG 10 AWG 6 AWG CONDUCTOR AMPACITY 30A 40A 40A 40A 75A --A —A V AMBIENT TEMPERATURE ADJUSTMENT FACTOR 1 1 1 1 1 -- N C CONDUIT FILL ADJUSTMENT FACTOR 1 1 1 0.8 00 < ADJUSTED CONDUCTOR AMPACITY 30A 40A 32A 40A 75A --A —A —A —A --A WIRE RUN DISTANCE(FT) 52 55 20 5 10 -- (N O CALCULATED VOLTAGE DROP 0.52% 0.61% 0.22% 0.1% O.OW% 0% 0% 0% 0% 0% A, 1 — Y/ r 0) U O PV CIRCUIT SPECIFICATIONS �l U PRIMARY STRUCTURE DETACHED STRUCTURE Q y CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS CIRCUIT61 CIRCUIT 7 CIRCUITS CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 1 CIRCUIT 5 NUMBER OF MODULES PER CIRCUIT 8 7 0 0 0 0 1 0 0 0 0 0 0 0 RATED AC OUTPUT CURRENT(lour) 10.8A 9.5A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA MINIMUM AMPACITY(lour x 125%) 13.5A 11.8A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA OVERCURRENT PROTECTION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A Z a N COMBINED AC OUTPUT CURRENT(Cow) 20.3A O.OA Z d MINIMUM AMPACITY(Cow x 125%) 25.3A O.OA Q COMBINED PV BREAKER RATING 30AA OA :E U O � U Q � TOTAL PROJECT ID: VOLTAGE DROP 1002663 VOLTAGE DROP WIRE TAG#1 0.52% PV DC SYSTEM SIZE: WIRE TAG#2 0.61% 6.300 kW DC WIRE TAG#3 0.22% WIRE TAG#4 0.1% PV AC SYSTEM WIRE TAG#5 0.08% 4.875 kW AC WIRE TAG#6 0% REVISIONS: TOTAL 1.530000% A ---- zi --- DRAWN BY: Brendan Fillmore PLOT DATE: June 29,2024 DRAWING TITLE: Electrical Calculations DRAWING NUMBER: PV6 WARNING LABELS N%ovp- BLUE RAVEN SOLAR UTILITY METER MAIN SERVICE PANEL AC DISCONNECT 1403 N 630 E Orem, Utah 84097 (800) 377-4480 PHOTOVOLTAIC SYSTE% Blue RovenSolar.com I AC DISCONNECTI RATED AC OUTPUT CURRENT 20.3 A NOMINAL OPERATING AC VOLTAGE 240 V �WARNING� ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND V LOAD SIDES MAY BE ENERGIZED PV COMBINER BOX (+7 } IN THE OPEN POSITION CV N SOLAR PVSYSTEM EQUIPPED 00 N 0 WITH RAPID SHUTDOWN •• H Lu Q N �„„ ,,sH�T�r,•, FOR SOLAR PV SYSTEM PHOTOVOLTAIC SYSTEM L Z 3 SWITCH TO THE OEE Pp$1TONT0 COMBINER PANEL - O 4— Si,UTOO"PV SYSTC„ AOL Rewce QWARNING ,� Q sHoI WARD IN THE ARRAY AUTHORIZED PERSONNEL ONLY d) 00 3 Q IL DO NOTADD LOADS (V `1.— NO DC WIRES PRESENT W (7 O RAPID SHUTDOWN O j TEST NOT REQUIRED } 0) U o U Q N O O f Q � Z <6< v/ 6 C O � U O 3 x — U PROJECTID: A CAUTION 1002663 MULTIPLE SOURCES OF POWER PV DC SYSTEM SIZE: POWER TO THIS BUILDING IS ALSO 6.300 kW DC SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY.PV DISCONNECT IS PV AC SYSTEM SIZE: LOCATED WITHIN 10 FTAND LINE OF SIGHT OF UTILITY METER 4.875 kW A REVISIONS: A ---- AWARNING 0 ---- DUAL POWER SUPPLY SOURCES:UTILITY GRID AND DRAWN BY: PV SOLAR ELECTRIC SYSTEM Brendan Fillmore PLOT DATE: June 29,2024 DRAWING TITLE: 7 - PV7_____j OF EMERGENCY, SE CONTACT.• Warning AVEN SOLAR Labels )377�480 DRAWING NUMBER: ELECTRICAL SPECIFICATIONS 420 430 BLUE RAVEN Test Conditions c STC NOCT -. - Module Power(Pmax) Wp 420 313 430 1 321 Maximum powervoltage(Vpmax) I V 3308 3086 33.25 31.02 Maximum power current(Ipmax) A 12.70 10.15 12.93 10.33 a ® Open circuit voltage(Voc) V 38.84 36.52 38.91 I 36.58 �� Short circuit current(Isc) A 13.50 1085 13.87 11.15 PRIME NTC Module efficiency % 21.5% 20.1% 22.1% 20.6% 5 O L A P-, Maximum system voltage(VDC) V 1000 SI' 420/430 QD Series fuse rating A 25 Power Tolerance Wp 0to+10 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25"C•NOCT Boo W/m'•AM 1.5•Measurement uncertainty as 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10 W. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight I 21 kg±0.2 kg 46.3lbs±0.4Ibs Dimensions(H x L x D) 1721 mm x 1133 mm x35 mm 67.8 in x 44.6 in x 1.37 in Maximum surface load(wind/snow)' I 4000 Pa rear load/5400 Pa front load I 83.5 Ib/ft2 rear load/112.8 Ib/R2 front load Hail impact resistance I o25mmat11km/h mlinat51.6mph Cells 108 Ha If cells-N-Type Silicon solar cell 108 Half cells-N-Type Silicon solar cell 182 mm x91 mm 7.16 in 3.58 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, antireflective coating antireflective coating Cables and connectors(referto installation manual) I 1350 mm,o 5.7 mm,MC4 from Staubli 53.1 in,o 0.22 in(12AWG),MC4from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame I Anodized aluminum(Black) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated,3 diodes TEMPERATURE RATINGS WARRANTIES Temperature Coefficient lsc 0.04%/"C Module product workmanship warranty 25 years" Temperature Coefficient Voc -0.24%/'C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.29%/"C >_98%end 1st yr >_94.T%end 12th yr NOCT(±2"C) 45•C a 90.8%end 25th yr Operating temperature -40/+85"C >_89.3%end 30thyr CERTIFICATIONS SHIPPING SPECS UL 61215,UL61730,CSA C22.2#61730,IEC 61215,IEC 61730,IEC 61701(Salt Mist Modules Per Pallet: 26 or 26(California) Product Corrosion),IEC 62716(Ammonia Corrosion),CEC Listed,UL Fire Rating:Type 2 Pallets Per Truck 32 or30(California) • Factory IS09001:2015 Modules Per Truck 832 or 780(California) A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. •• 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at si l fa bso lar.co m. PAN files generated from 3rd party performance data are available for download at:si Ifabsolar.com/downloads. _ 1 I v A. _ 67.8"11721 mm] E E 11.8"[300.5mm] 44-1"[1120mm] 11.8"1300.5mm] - I I 6 INTRODUCING NEXT- GENERATION Mounting Hole(x4) i 5• N - TYPE CELL TECHNOLOGY 112mm, !--�-- t --� SILFAB SOLAR INC. - • Improved Shade Tolerance • Enhanced Durability d 1.4"[35mm] 1770 Port Drive • Improved Low-Light Performance • Reduced Degradation Rate _ E = E E Burlington WA98233U5A Y 1� o� �� E o E m T+1360.569.4733 • Increased Performance in Industry-Leading Warranty a info@silfabsolaccom ca - SILFABSOLAR.COM High Temperatures 3 13 0.06" " v 7149 Logistic Lane ' - [1.5mm] E o Fort Mill SC 29715 USA tE T+1839.4.400.4330.4338 C 53 15" G c 240 Courtneypark Drive East I L F/ $ L R• ®I� - able Lengmm]th o Mississauga ON L5T2V3 Canada Cable Length o c9 T+1905.255.2501 ,.Drainage Hole(x8) B F+1905.696.0267 !• I 1 Silfab-SIL-420/430-QD-20240227 No reproduction of any kind is allowed without permission DRAWING NUMBER: 2.4"[60mm] B"[200mm] _ _ notaandinfalbSoLaoisubjecttofabSolar-is a without Kil tmdernark fabsolaoiar 2o2l.silfah solar•i:a registered F • trademark of silFab Solar Inr. SS memoo U N I RAC BLUE RAVEN April 11a',2024 SOLAR To Whom It May Concern, This letter is confirmation that the Silfab SIL-xxx QD module is compatible with Unirac's SFM racking system. The Silfab SIL-xxx QD module has been reviewed to ensure that,when installed with SFM, all structural and grounding and bonding features of the racking system mate properly with the module's frame. Silfab SIL-xxx QD is UL fire rated as a Type 2 module, for which the SFM system is UL 2703 certified. The Unirac product warranty applies to the installation of the Silfab SIL-xxx QD module with SFM. Please contact Unirac with any questions. Regards, Robert D'Anastasio Validation Engineer robert.danastasio@unirac.com Unirac, Inc. • www.unirac.com DRAWING NUM BER: ('� 1411 Broadway Blvd. NE • Albuquerque, NM • 87102-1545 • Ph: (505) 242-6411 • Fax: (505) 242-6412 J ENPHASE. ® cmm IQ8M and IQ8A Microinverters BLUE RAVEN Commonly used module pairings' w 260-460 295-500 Module compatibility To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module I... Module compatibility can be checked at fit ps://enphaso com/installers/microinverters/calculator MPPT voltage range V 30-45 32-45 Operating range V 16-58 Minimum/Maximum start voltage V 22/58 Maximum input DC voltage V 60 Maximum continuous input DC current A 12 Maximum input DC short-circuit current A 25 Maximum module I., A 20 Overvoltage class DC port 11 DC port backfeed current mA 0 PV array configuration 1 x 1 ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA JAC) UNITS '' Peak output power VA 330 366 Maximum continuous output power VA 325 349 1 Q 8 M and 1 Q 8A Microinverters Nominal grid voltage(L-L) V 240,split-phase(L-L),180° Minimum and Maximum grid voltage2 V 211-264 Our newest IQB Microinverters are the industry's first microgrid-forming,software- Maximum continuous output current A 1.35 1.45 defined microinverters with split-phase power conversion capability to convert DC Easy to install • Lightweight and com act with plug- is Nominal frequency Hz 60 power to AC power efficiently.The brain of the semiconductor-based microinverterP P B- and-play connectors Extended frequency range Hz 47-68 is our proprietary application-specific integrated circuit(ASIC),which enables . power line communication(PLC) the microinverter to operate in grid-tied or off-grid modes.This chip is built using between components AC short-circuit fault current over Arms 2 advanced 55-nm technology with high-speed digital logic and has superfast Faster installation with simple two- three cycles response times to changing loads and grid events,alleviating constraints on battery wire cabling Maximum units per 20 A(L-L)branch 11 circuit' sizing for home energy systems. High productivity and reliability Total harmonic distortion % c5 Produce power even when the grid Overvoltage class AC port III is down ' More than one million cumulative AC port backfeed current mA 30 �! hours of testing Power factor setting 1.0 Class II double-insulated enclosure • Optimized for the latest high- Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging powered PV modules Peak efficiency % 97.8 97.7 Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability CEC weighted efficiency % 97.5 97 Complies Microinverters integrate with the IQ Battery, standards with more than one million MCid-forming IQ Gateway,and the Enphase App monitoring and cumulative hours of power-on testing, Complies with the latest advanced Nighttime power consumption mW 21 22 analysis software. enabling an industry-leading limited warranty grid support** MECHANICAL DATA of up to 25 years. Remote automatic updates for the latest grid requirements Ambient temperature range -40•Cto 60•C(-40'F to 140°F) Configurable to support a wide Relative humidity range 4%to 100%(condensing) ,yam range of grid profiles Meets CA Rule 21(UL 1741-SA)and IEEE DC connector type Staubli MC4 1547:2018(UL 1741-SB 31d Ed.) Dimensions(H-W x D) 212 mm(8.31 x 175 mm(6.9")-30.2 mm(1.2") NOTE Weight 11 kg(2.43lbs) IQB Microinverters cannot be mixed together with Cooling Natural convection-no fans Connect PV modules quickly d easily to the IQ8 Series Microinverters are UL Listed as previous generations of Enphase microinverters q y an eas y Approved for wet locations Yes IQB Series Microinverters that have integrated PV rapid shutdown equipment and conform (IQ7 Series,I06 series,and soon)in the same PP MC4 connectors. with various regulations when installed system. Pollution degree PD3 according to the manufacturer's instructions. IQ Gateway is required to change the default grid profile at the time of installation to meet the local Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure Authority Having Jurisdiction(AHJ)requirements. Environmental category/UV exposure rating NEMA Type 6/outdoor Meets UL 1741 only when installed with IQ System Controller 2. ••I08M and IQBA support split-phase,240 V installations only. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. DRAWING NUMBER: (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. I08MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 I08 MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 SS Enphase Q Cable Accessories CONDUCTOR SPECIFICATIONS Certification UL3003(raw cable),UL 9703(cable assemblies),DG cable Flame test rating FT4 Compliance RoHS,OIL RES I,CE,UV Resistant,combined UL for Canada and United States Conductortype THHN/THWN-2 dry/wet The Enphase Q Cable"" and accessories are part of Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ System'".These disconnect required by NEC 690. accessories provide simplicity, reliability,and faster Q CABLE TYPES/ORDERING OPTIONS Installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Q-12-20-200 12 AWG/277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Field-wireable connector(male) Q-CONN-10M Make connections from any open connector Two-wire,double-insulated Enphase Q Cable Field-wireable connector(female) Q-CONN-10F Make connections from any Q Cable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Enphase cable • Disconnect tool Q-DISC-10 Disconnect too[for Q Cable connectors,DC connectors,and AC module mount New cable numbering and plug and play connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling wire management Terminator Q-TERM-10 Terminator cap for unused cable ends • Link connectors eliminate cable waste Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4(TE PV4-S SOLARLOK). 150mm/5.9"to MC4. Enphase EN4 non-terminated adaptor' ECA-EN4-FW Forfield wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non-terminated cable.150mm/5.9" Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use with split Field-Wireable Connectors cell modules or PV modules with short DC cable.600mm/23.6" • Easily connect Q cables on the roof without Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptor to MC4(max voltage 100 VDC) complex wiring Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable within 1.Qualified per UL subject 9703. branch limits • Available in male and female connector types TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL a CABLE CLIP Plan to use at least one per Used to fasten cabling tathe racking installation,sold in packs of ten or to secure looped cabling,sold in P (Q-DISC-10) packs of one hundred(Q-CLIP-100) To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ E N P H A S E• Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. E N P H A S E. To learn more about Enphase offerings,visit enphase.com u 2020 06 26 `� DRAWING NUMBER: SS Nee- ENPHASE. IQ Combiner 5/5C BLUE RAVEN MODEL NUMBER IQ Combiner 5 with 10 Gateway printed circuit board for integrated revenue-grade PV production IQ Combiner 5(X-IQ-AM1-240-5) metering(ANSIC12.20±0.5%),consumption monitoring(±2.5%),and IQ Battery monitoring(±2.5%). Includes a silver solar shield to deflect heat. 10 Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production IQ Combiner SC(X-IQ-AM1-240-5C) metering(ANSI C12.20±0.5%),consumption monitoring(±2.5%)and 10 Battery monitoring(±2.5%). Includes Enphase Mobile Connect cellular modem(CELLMODEM-W-06-SP-05)'.Includes a silver solar shield to deflect heat. WHAT'S IN THE r IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive,remote maintenance,and management of the Enphase Energy System Busbar 80 A busbar with support fort•IQ Gateway breaker and 4.20 A breaker for installing IQ Series Microinverters and 10 Battery 513 IQ Gateway breaker Circuit breaker,2-pole,10 A/15 A Production CT Pre-wired revenue-grade solid-core CT,accurate up to±0.5% 1�---- X-I112-AM1-240-5 Consumption CT Two consumption metering clamp CTs,shipped withthe box,accurate up to±2.5% X-I0-AM7-240-5C IQ Battery CT One battery metering clamp CT,shipped with the box,accurate up to±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Q Combiner 5/5 C Enphase Mobile Connect(only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem(CELLMODEM-M7-06-SP-05)with a 5-year T-Mobile data plan Accessories kit Spare control headers forthe COMMS-KIT-02 board Smart The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and Includes IQ Gateway for ACCESSORIES AND REPLACEMENT PARTS(NOT INCLUDED, ORDER SEPARATELY) streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, communication and control CELLMODEM-M7-O6-SP-05 4G-based LTE-M1 cellular modem with a5-yearT-Mobile data plan Pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. Includes Enphase Mobile Connect CELLMODEM-MI-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan (CELLMODEM-MI-06-SP-05),only The IQ Combiner 5/5C,IQ Series Microinverters,IQ System Controller 3/3G,and IQ Battery with IQ Combiner 5C Supports Eaton BR2XX,SiemensQ2XX and GE/ABB7HQLZIXX Series circuit breakers t b represents 5P provide a complete grid-agnostic Enphase Energy System. Circuit breakers(off-the-shelf) 10,15,20,30.40,50,or 60).Also supports Eaton BR2206,BR230B.and BR240B circuit breakers Supports flexible networking:Wi-Fi, compatible with the hold-down kilt Ethernet,or cellular BRK-10A-2-240V,BRK-15A-2-240V,BRK-20A-2P-240V,BRK-15A-2P-240V-B,and BRK-20A-2P- Provides production metering Circuit breakers(provided by Enphase) 240V-B(more details in the Accessories"section) (revenue grade)and consumption monitoring XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for 10 Combiner 5/5C Easy to install L X-I0-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws) IQ Series Microinverters IQ System Controller 3/3G Mounts to one stud with centered XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board(PCB)for IQ Combiner 5/5C The high-powered smart grid-ready IQ Series Provides microgrid interconnection brackets Microinverters(I06,IQ7,and IQ8 Series)simplify device(MID)functionality by Supports bottom,back,and side ELECTRICAL SPECIFICATIONS the installation process. automatically detecting grid failures and conduit entries seamlessly transitioning the home energy Rating 80 A system from grid power to backup power. Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers System voltage and frequency 120/240 VAC,60 Hz (not included) Busbar rating 125 A 80 A total PV branch circuits Fault current rating 10 kAIC Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Maximum continuous current rating(input from PV/storage) 64 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR,Siemens O,or GE/AE1B THOL Series distributed generation(DG)breakers Reliable only(not included) IQ Battery SIP IQ Load Controller Durable NRTL-certified NEMA type 311 Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 Awith IQ Gateway breaker included enclosure Fully integrated AC battery system.Includes six Helps prioritize essential appliances IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included field-replaceable IQ8D-BAT Microinverters. during a grid outage to optimize energy 5-year limited warranty consumption and prolong battery life. Production metering CT 200 A solid core pre-installed and wired to IQ Gateway 2-year labor reimbursement program coverage included for both the Consumption monitoring CT(CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box IQ Combiner SKUs IQ Battery metering CT 200 A clamp-style current transformer for 10 Battery metering,included with the box NOM UL7741 Listed �S LISTED � 1. Aplug-and-play Industrial-grade cell modem for systems of up to 60 mlcroinverters.Available In the United States,Canada,Mexico,Puerto Rico, and the US rgin Islands,where there Is adequate cellular service In the Installation area. 5-year limited warranty *For country-specific warranty information,seethe htips•//enphase comAnstallers/resources/warranty page. ®2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at DRAWING NUMBER: MtasJ/onohasemm/tryQqMnrk-,?mqe.au; o�.� ,are trademarks of Enphase Energy,Inc.In the U.S.and other countries. Data subject to change. ioc-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IOC-S-SC-DSH-00007-3.0-EN-US-2024-03-01 SS MECHANICAL DATA Accessories 37.5 cm x 49.5 cm x 16.8 cm(14.75"•19.5"x 6.63").Height is 21.06"(53.5 cm)with mounting Dimensions(W x H x D) brackets Weight 7.5 kg(16.5lbs) Mobile Connect Circuit breakers 4G-based LTE-M1 cellular modem with a 5-year BRK-IOA-2-240V Circuit breaker,2-pole,10 A,Eaton BR210 Ambient temperature range -40°C to 46°C(-40°F to 115°F) data plan BRK-15A-2-240V Circuit breaker,2-pole, A,Eaton BR215 Cooling Natural convection,plus heat shield (CELLMODEM-Ml-06-SP-05 for Sprint and BRK-20A-2P-240V Circuit breaker,2-pole,20 A,Eaton BR220 CELLMODEM-MI-06-AT-05 for AT&T) BRK-15A-2P-24OV-B Circuit breaker,2-pole,15 A,Eaton BR215B Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction with hold-down kit support BRK-20A-2P-24OV-B Circuit breaker,2-pole,20 A.Eaton 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors BR220B with hold-down kit support 60 A breaker branch input:4 to 1/0 AWG copper conductors Wire sizes Main lug combined output 10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing Built-in CTRL board for wired communication with IQ Battery 5P and IQ System Controller 3/3G. Communication(in-premise connectivity) Integrated power line communication for IQ Series Microinverters CT-200-SOLID CT-200-CLAMP Altitude Up to 2,600 meters(8,530 feet) 200 A revenue-g rode solid core Production CT 200 A clamp-style consumption and battery *I COMMUNICATION with<0.5%error rate(replacement SKU) metering CTwrth<2.5%error rate(replacement Integrated WI-Fi 802.11b/g/n(dual band 2.4 GHz/5 GHz),for connecting the Enphase Cloud through the internet - SKU) ���- Wi-Fi range(recommended) 10 m(32.8 feet) Bluetooth BLE4.2,10 m range to configure WI-Fi SSID Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included),for connecting to the Enphase Cloud through the internet Cellular/Mobile Connect CELLMODEM-M1-06-SP-05 or CELLMODEM-MI-06-AT-05(included with IQ Combiner 5C) Digital 1/0 Digital input/output for grid operator control USB 2.0 Mobile Connect,COMMS-KIT-01 for 10 Battery 3/3T/10/10T,COMMS-KIT-02 for IQ Battery 5P Access point(AP)mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs,one 10 Battery CT,and one Production CT Power line communication 90-110 kHz Web API See https://developef-v4.enphase.com Local API See guide for local API COMPLIANCE UL 1741,CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003,NOM-208-SCFI-2016, 10 Combiner with IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1,IEEE 1547:2018(UL 1741-SB,3rd Ed.),IEEE 2030.5/CSIP Compliant,Production metering:ANSI C12.20 accuracy class 0.5(PV production) COMPATIBILITY PV Microinverters IQ6,107,and 108 Series Microinverters IQ System Controller EP20OG101-M24OUS00 COMMS-KIT-01 P IQ System Controller 2 EP2000101-M24OUS01 10 Battery ENCHARGE-3-1P-NA,ENCHARGE-10-1P-NA,ENCHARGE-3T-lP-NA,ENCHARGE-10T-lP-NA IQ System Controller 3 SC200D111C240US01,SC200G111C240US01 COMMS-KIT-02' IQ Battery IQBATTERY-5P-IP-NA DRAWING NUMBER: 2. For Information about IC Combiner 5/5C compatibility with the 2"-generatlon batteries,refer to the comoatlbslity matrix. 3. 10 Combiner 5/5C comes pre-equipped with COMMS-KIT-02. ICC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 ICC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 SS F_ BLUE RAVEN Data Sheet Enphase Networking 1403 N Research Way Enphase IQ Envoy Orem,UT84097 800.377.4480 W W W.BLUERAVENSOLAR.COM MODEL NUMBERS Enphase IQ Envoy" Enphase IQ Envoy communications gateway with integrated revenue grade PV CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE ENV IQ AM1-240 production metering(ANSI C12.20+/-0.5%)and optional consumption monitoring(+/-2.5%). USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN Includes SHALL IT SOLAR O BE DISCLOSED WHOLE OLE OR The Enphase IQ Envoy"communications gateway one 200A continuous rated production CT(current transformer). IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT delivers Solar production and energy consumption ACCESORIES(Order Separately) IN CONNECTION WITH THE SALE AND Enphase Mobile Connect" Plug and play industrial grade cellular modem with data plan for systems up to 60 USE OF THE RESPECTIVE EQUIPMENT, data to Enphase Enlighten'" monitoring and analysis CELLMODEM-M1(4G based LTE-M/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin WITHOUT THE WRITTEN PERMISSION software for comprehensive,remote maintenance and CELLMODEM-MI-B(4G-based LTE-M1/5-year data plan) Islands,where there is adequate cellular service in the installation area.) OF BLUE RAVEN SOLAR LLC. Consumption Monitoring CT Split-core consumption CTs enable whole home metering. management of the Enphase IQ System. CT-200-SPLIT Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge"storage N ABCE P COMMS-KIT-01 and Enphase Enpower"smart switch.Includes use cable for connection to IQ CERTI F I E D With integrated revenue grade production metering Envoy or Enphase IQ Combiner"and allows wireless communication with Encharge and Enpower. PV INSTALLATION and optional consumption monitoring, Envoy IQ is the POWER REQUIREMENTS _ PROFESSIONAL platform for total energy management and integrates Power requirements 120/240 VAC split-phase. Scott Gurney Max 20 A overcurrent protection required. #PV-011719-015866 with the Enphase Ensemble'and the Enphase IQ Typical Power Consumption 5W CONTRACTOR: Battery'. CAPACITY BIRS FIELD OPS Number38 of microinverters polled Up to 600 5-498-6700 MECHANICAL DATA Dimensions(WxHxD) 21.3 x 12.6 x 4.5 cm(8.4"x 5'x 1.8') Smart Weight 17.6 oz(498 g) Enables web-based monitoring Ambient temperature range -40'to 65'C(-40'to 149'F) ENPHASE and control -40'to 46°C(-40'to 115"F)if installed in an enclosure Bidirectional communications for Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure. remote upgrades Altitude To 2000 meters(6,560 feet) Supports power export limiting and Production CT Limited to 200A of continuous current/250A OCPD-72kW AC Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) zeroexport applications UL2808 certified for revenue grade metering Consumption CT For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84"x 0.96"(21.33mm x 24.38mm)to support Simple 3/0 THWN conductor UL2808 certified,for use at service entrance for services up to 250Vac Easy system configuration using Enphase InstallerToolkit'"mobile app INTERNET CONNECTION OPTIONS Flexible networking with Wi-Fi, Integrated Wi-Fi 802.11b/g/n Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLMODEM-M1 (4G)or CELLMODEM-MI-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable COMPLIANCE Compliance UL 61010-1 Designed for installation indoors CAN/CSA C22.2 No.61010-1 or outdoors 47 CFR,Part 15,Class B,ICES 003 DRAWING BY: • Five-year warranty IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 Metering:ANSI C12.20 accuracy class 0.5(PV production only) PLOT DATE: PROJECT NUMBER: -'"� To learn more about Enphase offerings,visit enphase.com E N P H AS E• SHEET NAME E N P H AS E. To learn more about Enphase offerings,visit enphase.com v©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,and other trademarks or service names are the trade- SPEC SHEET marks of Enphase Energy,Inc.Data subject to change.06-30-2021 REVISION: PAGE NUMBER: ---- SS BLUE R 6.63 .62 DIA WIRING DIAGRAMS 16 168 31 DIA FUSIBLE + e .50 13 QQ Q44 �- ci•' — A B 0 TERMINAL LUGS AMPERES MAX. WIRE MIN. WIRE TYPE 14.88 11 .24 O 60 -f�3 AWG #14 AWG CU OR AL 376 285 KNOCKOUTS CONDUIT SIZE DIAMETER SYMBOL IN MM IN MM KNOCKOUTS A,B,C A .50 13 88 22 KNOCKOUTS B .7s 19 1.13 29 C 1.00 25 1.38 35 D 1.25 32 1175 45 1 .64 42L-3.76 4.87 96 124 .31 DIA 8 7.45 (2 HOLES) 189 NEMA TYPE 3R A,B,C,D KNOCKOUTS �� ^��) �.�� A l y �J' l� KNOCKOUTS DUAL DIMENSIONS: INCHES MILLIMETERS .28 DIA KNOCKOUT A,B,C HORSEPOWER RATINGS 7 KNOCKOUTS CATALOG AMPERE 240VAC NOTES: NUMBER VOLTAGE RATINGS DI AG.G RATING STD. MAX. FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITED OVER CLEANED PHOSPHATIZED STEEL UL LISTED - FILE E-2875 1 03 1 3 ALL NEUTRALS - INSULATED GROUNDABLE D222NRB 240VAC A 60 3 7.50• 10 15• SUITABLE FOR USE AS SERVICE EQUIPMENT D322NRB 240VAC B 60 3 CIE 7.50 10 15 SHORT CIRCUIT RATINGS: 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES TOP ON NEMA 3R ENCLOSURES HAVE PROVISIONS FOR MAXIMIM 2.50 BOLT-ON HUBS. WHEN MOUNTING THESE SWITCHES, ALLOW 3.00 IN / 76 MM MIN. CLEARANCE BETWEEN ENCLOSURES FOR OPENING OF SIDE HINGED DOOR. GENERAL DUTY SAFETY SWITCHES a SQUARE O COMPANY X USE OUTER SWITCHING POLES VISIBLE BLADE TYPE •FOR CORNER GROUNDED DELTA SYSTEMS ONLY. 60 AMPERE f LUGS SUITABLE FOR 60°C OR 75°C CONDUCTORS. ENCLOSURE - NEMA TYPE 3R RAINPROOF DWG. N0. 1863 REF DWG x1863 JUNE 2000 DRAWING NUMBER: ss EZfSOLARJB- 1 .2 , JB- 1 .XL EZf SOLAR PHONE:385-202-4150 s Specification Sheet maHmQ solar simple. WWW,EZSOLARPRODUCTS,COM making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs A. System Specifications and Ratings ITEM NO. PART NUMBER DESCRIPTION QTY SIZE DWG.NO. REV POLYCARBONATE B J B-1.2 • Maximum Voltage: 1,000 Volts 1 JB-1,2 BODY WITH UV INHIBITORS 1 SCALE 1:2 WEIGHT:1.45 L85 SHEET 10F 3 • Maximum Current: MA I: 80 Amps; JB-1.XL: 120 Amps • Allowable Wire: 14 AWG—6 AWG 2 JB-12 LID WITH UV R INHIBITORS 1 WITH UV INHIBITORS TORQUE SPECIFICATION: 15-20 LBS • Spacing: Please maintain a spacing of at least'/2" between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. 3 #10 X PAN HEAD HEAD SCREW PHILLIPS 6 CERTIFICATION: UL 1741,CSA C22.2 0.NO.NEM 290 • Enclosure Rating: Type 3R • Roof Slope Range: 2.5— 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS • Max Side Wall Fitting Size: 1" PAN HEAD SCREW • Max Floor Pass-Through Fitting Size: 1" • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: -JB-1.2: UL1741, CSA C22.2 No. 290; JB-1.XL: UL1741, CSA C22.2 No. 290 -Approved wire connectors: must conform to UL1741, CSA C22.2 No. 290 System Marking: Interek Symbol and File#5019942 5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. Table 1:Typical Wire Size,Torque Loads and Ratings 1 Conductor 2 Conductor - Torque e - Type NM I Inch Lbs Voltage current ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 6.2-8.85 600V 30 amp ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 am 9 279,68mm] 276.30mm] ABB ZS16 terminal block 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp 1 I.01 in 10.88in ? ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp Ideal 452 Red =C 8-18 awg Sol/Str Self-Torque Self-Torque 600V I SOLAR Ideal 451 Yellow S�.°=u' 10-18 awg Sol/Str Self-Torque Self Torque 600V A R Ideal, In-Sure P„ 10-14 awg Sol/Str Self-Torque Self-Torque 600V jB-1.2 WAGO,2204-1201 10-20 awg 16-24 awg Sol/Str Self-Torque SelfTorque 600V 30 amp WAGO,221-612 10-20 awg 10-24 awg Sol/Str If-Torque Self-Torque 600V 30 amp I Dottie DRC75 6-12 awg Sol/Str Snap-In Snap-In ESP NG-53 4-6 awg_ _ Sol/Str 45 2000V 10-14 awg Sol/Str 35 � S 4-6 awg Sol/Str 45 ESP NG-717 10-14 awg Sol/Str 35 2000V Brumall 4-5,3 4-6 awg Sol/Str 45— _ 10-14 awgSol/Str 35 2000V �183A6mmf _ - - 7.21 in 2.$6in Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) I265.1$mm! 10.44in Wines per terminal(pole) Wire size,AWG or 1 2 3 4 or More kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not Specified ' 8 (8.4) 38.1 (1-1/2) 6 (13.3) 50.8 (2) - - - PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. DRAWING NUMBER: ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. 5015705 SS WSOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM ISSUE DATE: ISSUE DATE: BLUE RAVEN RIGID PVC CONDUIT FITTINGS DATE D'EMISSION: 2009 04 30 RIGID PVC CONDUIT FITTINGS DATE D'EMISSION: 2009 04 30 SnLAR SUPERCEDES: SUPERCEDES: JB444 JUNCTION BOXES REMPLACE: 2004 07 15 JB444 JUNCTION BOXES REMPLACE: 2004 07 15 5 _ COVER DIMENSIONS 4.010" _ (102mm) B AC E 4.010" (102mm) C B D PRODUCT PART NOMINAL SIZE A B C CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (in) (mm) 0.245" 076668 J444 STAHLIN 4 103 3.675 93 4.000 102 3.450 88 076259 AMJB444 ALLIED 4 103 3.675 93 4.000 102 3.450 88 (6 mm) �I 077643* 2037-424T CANLET 4 103 3.675 93 4.000 102 3.450 88 077696 JB 444 4 103 4.000 101 4.395 112 3.950 101 PRODUCT PART NOMINAL SIZE D E VOLUME 0.190" DIA CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (cu. In) (cu.Cm) 076668 J444 STAHLIN 4 103 4.180 106. 3.850 98 51.5 844.6 076259 AMJB444 ALLIED 4 103 4.180 106 3.850 98 51.5 844.6 077643* 2037-424T CANLET 4 103 4.180 106 3.850 98 51.5 844.6 0 iM>> 077696 JB 444 4 103 4.170 106 3.930 100 51.5 844.6 0.25 PRODUCT PART NOMINAL SIZE GASKET I INSERT I SCREW M.FEET CODE NUMBER (in) (mm) CODE CODE CODE CODE Small Mounting Feet 076668 J444 STAHLIN 4 103 072538(4) 1.970" Product Code 097747 076259 AMJB444 ALLIED 4 103 072538(4) 077643* 2037-424T CANLET 4 103 072538(4) 0.175° 077696 JB 444 4 103 097731 072538(4) 072522(4) 097747 072539(2) 072513(2) *BOX WITH MOLDED MOUNTING FEET,INSERT ONLY;NO COVER,OR GASKET,UL LISTED 576J DRAWING NUMBER' Page: CONDUIT-41.1 Page: CONDUIT-41. ss BLUE RAVEN SOUR "Stay Connected"with HEYC 4 SolarPowercomponents k k k r- , Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW) The Ultimate in Liquid Tight Strain Relief Protection PRODUCT!, GLAND PART NO. DESCRIPTION PART DIMENSIONS .Two new cordgrips now accommodate CONFIGURATION &2 A B C D E the Enphase Q Cable-M3231 GCZ Conductors or Clearance Max.O.A. Thread Wrenching Not (1/2"NPT)and M3234GDA-SM Type i Size No. Black 94. Hole Dia. Length 'Length Thlclmess',Flat Slte (3/4"1 NPT). mm. in. Imm. in.I mm.l in.lmm in.I mm.l In.I mm. -The 1/2-version provides liquid tight Oval Gland 0 Cable 16,1 x 9,71 1 IM3231GCZ I LTCG 1/2 6.1x9.7MM IS/�s I.875I22,2I1.70 43,2I.61115,51.21 15,3I .98124.9 entry for one Enphase QCable- .24 x.38""(6,1 x 9,7 mm). Break-Thru Skinned Over Gland •The 3/4""version provides liquid tight O cables!6.1x9,712I SMCG3142-6.1x9.7MM II II I 1 plus M3234GDA SM I�/Sn11.040`26,4I2.0 50,81.62 15.7i 25 6,4I1.30 33,0 entry for up to two Enphase QCables- Ground 3,3 1 I1-33MM II II I I I 24 x.38 (6,1 X 9,7 mm)and an Metal Locluluts INCLUDED. B additional.130"(3,3 mm)dia.hole for 9a#8 solid grounding cable. D Al •The 3/4""version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. •Rated for use with DG Cable. SUGGESTED CLEARANCE HOLE SEALING NUT--' INTEGRAL FOR NONTHREADEO MOUNTING SEALING RING Material Nylon 6/6 with TPE Sealing Gland Certifications © Listed under underwriters'Laboratories File E504900 SP CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40OF(-400C)to 2390F(1150C) Dynamic-4°F(-20"C)to 212°F(100°C) IP Rating IP 68 DLEHeyco® Helios®UVX Clip-Blind MountP PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOuimilg OVERALL a The jersey pine tree mounting style RANGE HOLE OUL HEIGHT installs easily with superior holding Minimum Maximum 1-2 Wires A C power. in. mm. in. I mm. I in rnm, in mm -UVX nylon protects from corrosion due 1-2 Wires to outdoor exposure. .028 0,7 .250 6,4 [23(5,8 mm)-.32(8,0 mm) S6520 1Hellos UVX Cop 100 Pack 260 6,6 1.96 24,4 .Installs into.260""(6,6 mm)mounting each cable S6560 I Helios UVX Clip Bulkhole. •Holds up to 2 cables between .230- 315"(5,8-8,0 mm)each. c •Cables install with fingertip pressure. J ftA e Molded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F(-20°C)to 185°F(85°C) DRAWING NUMBER: 1-800-526-4182 a 732-286-1800(NJ)a FAX:732-244-8643•www.heyco.com 1-4b SS \141� BLUE RAVEN SOLAR .. U •_� N I RAC SFM INFINITY a=:= BETTER SOLAR STARTS HERE 0 00�is - 2 UL270.1 obi SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PARTNAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer .` attachments than rail systems. 2 INSTALLS PER DAY TRIMRAIL Structural front trim provides aesthetic and aligns modules. Make two installs per day your new standard.SFM INFINITY has fewer 1 RAIL SPLICE Connects and electrically bonds sections of TRIMRAIL roof attachments,one tool installation,and pre-assembled components TRIM to get you off the roof 40%faster. I ' i TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. SFM INFINITY 15 Attachments NMODULE CLIPS Secure modules to TRIMRAIL. - — MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. ■ — ,, BETTER AESTHETICS - - — - — - Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. '— ■ �i i] with integrated front trim,trim end caps,dark components,and ATTACHED SPLICE also available. recessed hardware. SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power densityto without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES With fewer stock,easier to t easier t and compact components,SFM INFINITY is easieraoransport,and easier to lift to the roof.Plus,make more attachments required by rail. PARTNAME DESCRIPTION efficient use of your vehicle fleet. tTRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules 0 N/S BONDING CLAMP Electrically bonds rows of modules • • • • SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS , FROM DESIGN AND LOGISTICS, THROUGH I ARRAY INSTALLATION AND SERVICE. DRAWING NUMBER: SS '4� ■ ■ SUN i BLUE RAVEN 19 SOLAR NN■ S F M FRAME - �■ MICRORAILTM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ 0- U �s �r- E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. Star Washer is WEEBLUG Single Use Only Single Use Only Alternate method N-S BONDING PATH: TERMINALTORQUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMINALTORQUE, TERMINALTORQUE, bonding pins. (refer also to alternate method) 4-6 AWG: Min-lbs Install Conductor and Install Conductor and 8 AWG:25 in-lbs torque to the following: torque to the following: 10-14 AWG: 20 in-lbs 4-14 AWG: 35in-lbs 6-14 AWG:7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO - Ilsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7) • 10-32 mounting hardware e 1/4" mounting hardware 1/4" mounting hardware �, • Torque = 5 ft-lb Torque = 75 in-lb Torque = 10 ft-lb Alternate method • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded 0 AWG 6-14-Solid or Stranded TRIMRAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with System bonding is accomplished through modules.System grounding accomplished by attaching bonding clamp with integral bonding pin and bonding T-bolt. (refer also to alternate method) DRAWINGNUMBER: a ground Lug to any module at a Location on the module specified by the module manufacturer. S S i SUN i BLUE RAVEN mom ; FRAME UL CODE COMPLIANCE NOTES ZO SOLAR NN MICRORAIL TM INSTALLATION GUIDE ; PAGE ________ - ______________------------------------------------------------------------------------------------------------ SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures SUNFRAME MICRORAIL(SFM) Installation Guide.SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM.SUNFRAME MICRORAILTm components shall B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules.Class A, B & C system level fire Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C I East-West _ Landscape OR Portrait None Required __ 1 UL2703 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF/ 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa c) Down-Slope Load - 21.6 PSF/ 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF/ 8000 Pa b) Upward Pressure - 75 PSF/ 3500 Pa c) Down-Slope Load - 32.4 PSF/ 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less DRAWING NUMBER: SS ■ ■ SUN ' -, 22- aLUE RAVEN SFRAMETESTEDCERTIFIEDMODULE - SOLAR ■ F M MICRORAIL TM INSTALLATION GUIDE ; PAGE ---------------------__----------------------------------------------------____---------________ Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series ALeo P-Series Eco SoLargy Orion 1000 &ApoLLo 1000 LGxxxN2T-A4 ET SoLar ET-M672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ DNA-120-(BF/M F)26 Q1 C/Q1 K/S1C/S2W)-A5 Aptos Freedom Forever FF-MP-BBB-370 DNA-144-(BF/MF)26 LGxxxN2T-B5 FreeVoLt Mono PERC -- - - -� LGxxxN1K-B6 CHSM6612P,CHSM6612P/HV,CHSM6612M, GCL GCL-P6 &GCL-M6 Series - - LGxxx(A1 C/M 1C/M1 K/N1C/N 1 K/Q1C/Q1 K/ Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), TD-AN3,TD-AN4, I LG Electronics QAC/QAK)-A6 HansoL CHSM72M-HC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W)-E6 AXN6M610T,AXN6P610T, 36M,60M,60P,72M &72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 Auxin AXN6M612T&AXN6P612T Heliene 144HC M6 MonofaciaV BifaciaL Series, LGxxxN2T-15 AXIbLackpremium 60(35mm), 144HC M10 SL BifaciaL LGxxx(N1K/N1W/N2T/N2W)-L5 AXIpower 60(35mm), HT Solar HT60-156(M)(NDV)(-F), LGxxx(N1C/01C/Q1K)-N5 Axitec AXIpower 72(40mm), HT 72-156(M/P) LGxxx(N1C/N1K/N2W/Q1C/Q1K)-V5 AXIpremium 60(35mm), KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM Hyundai AXIpremium 72 (40mm). HiA-SxxxHG LR4-72(HIH/HPH)-xxxM Boviet BVM6610, ITEK iT,iT-HE &iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM(30mm) BVM6612 LR6-60(BK)(PE)(HPB)(HPH)-xxxM(35m m) Japan Solar JPS-60 &JPS-72 Series BYD P6K& MHK-36 Series -- - LONG LR6-60(BK)(PE)(PB)(PH)-xxxM(40mm) JAP6 60-xxx,JAM 6-60-xxx/SI,JAM 6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM(30mm) CS3(H/K/U CS /1�-MS xxx,JAP6(k)-72-xxx/4B B,1AP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(H PH)-xxxM (K/L/U),CS3K-MB-AG,CS3K-(MS/P) JAP6(k)-60-xxx/46B,JAP60SYY-xxx/ZZ, (35mm Canadian SoLar CS3N-MS,CS3U-MB-AG,C53U-(MS/P),CS3W ) JASoLar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM(40mm) CS5A-M,CS6(K/U),CS6K-(M/P),CS6K-MS JAM6(k)-60-xxx/ZZ,JAM605YY-xxx/ZZ. CS6P-(M/P),CS6U-(M/P),CS6V-M,CS6X-P Mission Solar Energy MSE Series - _- -- - i.YY:01,02,03,09,10 1 CentrosoLarAmerica C-Series & E-Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi MJE & MLE Series CT2xxMxx-01,CT2xxPxx-01, JKM &JKMS Series Neo SoLar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, Jinko Eagle JKMxxxM CTxxxMxx-04,CTxxxHC11-04 - I JKMxxxM-72HL-V ` Dehui DH-60M -- Kyocera KU Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7"between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information DRAWING NUMBER: SS i SUN , BLUE RAVEN 23 SOLAR ■� ■ SF FRAME WMICRORAILTM INSTALLATION GUIDF- I- PAGE _______________________________________________________________________________________________________________ _ ________ Manufacture Module Model/Series Manufacture Module ModeL/Series Manufacture ModuLe Model/Series EVPVxxx(H/K/PK), TwinPeak Series Suniva MV Series &Optimus Series VBHNxxxSA15 &SA16, TwinPeak 2 Series SunPower A-Series A400-BLK,SPR-MAX3 XXX-R, VBHNxxxSA17&SA18, REC Solar(cont.) TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series - Panasonic VBHNxxxSA17(E/G) &SA18E, TwinPeak2S(M)72(XV) Suntech STP,STPXXXS-B60/Wnhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38mm) TP572,TP596,TP654,TP660, VBHNxxxZA01,VBHNxxxZA02, TP4(Black) Talesun TP672,Hipor M,Smart VBHNxxxZA03,VBHNxxxZA04 Renesola Vitrus2 Series & 156 Series SC,SC B,SC B1,SC B2 Risen RSM72-6 MDG M,RSM60-6 Testa Peimar SGxxxM(FB/BF) � ( )( ) I TxxxH,TxxxS Phono Solar PS-60,PS-72 SEG Solar SEG-xxx-BMD-HV PA05,PD05,DD05,DE06,DD06,PE06, Prism Solar P72 Series SEG-xxx-BMD TB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy SN72 &SN60 Series(40mm) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim SEG-6 &SRP-6 Series Upsolar UP-MxxxP(-B), QPEAK DUO BLK-G6+ Sharp NU-SA& NU-SC Series UP-MxxxM(-B) QPEAK DUO BLK-G6+/TS SLA, SLG,BC Series &SlLxxx(BL,/NL,/NT/HL/ D7MxxxH7A,D7(M/K)xxxHBA + Silfab QPEAK DUO(BLK G8)- ( ) ML/BK/NX/NU/HC) United Renewable Energy FAKxxx(C8G/E8G),FAMxxxE7G-BB Q.CeLLs QPEAK DUO L-G8.3/BFF SoLarever USA SE-166"83-xxxM-12ON (URE) FAMxxxE8G(-BB) QPEAK DUO(BLK)ML-G9(+) FBMxxxMFG-BB Powe rXT-xxx R-(AC/P D/B D) QPEAK DUO XL-G9/0.2/0.3 Eldora, Solaria PowerXT-xxxC-PD QPEAK DUO(BLK) ML-G10(+) Vikram Solivo, PowerXT-xxxR-PM (AC) OYEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Somera Sunmodute Protect, QPEAK DUO BLK ML-G10+/t SoLarWorLd Sunmodute Plus Waaree AC&Adiya Series Alpha (72)(Black)(Pure) SS-M-360 to 390 Series, Winaico WST&WSP Series RECxxxAA PURE-R SS-M-390 to 400 Series, Yingli YGE&YLM Series RECxxxNP3 Black Sonali SS-M-440 to 460 Series, ZN Shine ZXM6-72, ZXM6-NH144-166_2094 N-Peak(Black) REC Solar SS-M-430 to 460 BiFaciaL Series, N-Peak 2 (Black) SS 230-265 PEAK Energy Series - - - PEAK Energy BLK2 Series SunEdison F-Series,R-Series & FLEX FXS Series PEAK Energy 72 Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • PLease see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information ss_m BLUE RAVEN S 0. 6. tntertek AUTHORIZATION TO MARK tntertek AUTHORIZATION TO MARK Total Quality.Assured, Total Qvaitry,Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Cowered section when made in aocordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and Is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark_ applied only at the location of the Party Authorized To Apply Mark, Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer. 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE Address: Ad-dress: Albuquerque, NM$7102 Address: Albuquerque, NM 871U Country: USA Country: Country: USA Country: Party Authorized To Apply Mark; Same as Manufa,cttirer Party Authorized To Apply Mark: Same as ManufaotL,rer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest,CA Report issuing Office., Intertek Testing Services NA, Inc,, LaKe Forest, CA Control Number: 5003705 Authorized by: �bl*W Control Number: 5014989 Authorized by: ��\\ �-R� for L, Matthew Snyder, Certification Manager for L Matthew Snyder, Certification Manager T - CO(Tus C Las � Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number, This document supersedes all previous Authorizations to Mark for the noted Report Number. rr.s A,9'xr,7 to Mar4 la for lha vrClusivl, +;d.Yltlrr4}k r;r•Cr[ t"—..I nle karw.8,CrUnl_U,rblak']rPGj nf:H,M%ly'Nr�5#`JiIN ara� Th.¢Atiltgv,lflti LLh4,n2 rrrr'-k-1—r a.'uwi C4v�ht<1on p�,»n.)nl!�NM+iMnbN.1M Af4 n+.�Hir1.Inlel—a a.,.d UaWily xt E,sr.�gd 14 1'H•nrr�d:3"d[Ya`111q•b ty d'A A4^'-^mi l In:NJPk.As:}U!Mx ro I,dlljihly D] 'WrC/-r/ftr Pyre n;nM•'�:Orfl art HIY,�efJbNJ!>••�;tllx!> 4onl.♦;r lti�}H7N3.Fr..,('nG(r nl:Ja.^.'aU�1,`•�C,G'ALrMr'y limll J k,{M Il"na ARi ri(�.K1 trCri ir!i'e R¢99A+41 Ink+1C1.dmf nl 7-0Il#A11ty IG!ny D.Y^f ,Y.�s 4'.fn I.�Sb[:7'N�'In d:cOr'.iY.;l'Nrflr i'1!rkTSeT="!.lyr mty kp».�r,.,,IrW S,!OkrtnpT JG'.!<'iil/:lCi� sk.Goio ri�4IK,e rn-,rk by the usd of 9!3 hullscssL;,llkx'+[c iila*Ortr the 61a[ma„zoomed Io iar.-r11 cop-,,ng c,=]ari lberdt .Fuh-.-nLrr,to hlsk and the c;4y In is e-K:rett VzHof lnlnrink'F CoMA"lltr,1n,!Ik,R by bw-., e cr lh+sh.g zabon4 i/ork_Onry the Gb 1.IsaAhofizzed to W-mi Zoe'—;cr dflel,,Ao oT,c to Mack-and 9 unYrits cnite!r Ur nI l.Y.+rc IesY,dnd ti Iaid W in a,a @11*te ors:aia]rrt d+s A,We,,hi.rton I:.irk Alta 5�r �,'d re tntnfle*rune,cr fit,%"or advtrFsamenl ul r x Iaf.1RA rvkv*rLw.P( !.rt a Fnr irYr nvw! reuntU7 IL Ihs corrOhWa tud w.in rw 491WIoxrf.and in IM Aut-�X2bf an In MaA.LW r f Lrwi IfWwo.rarrR h:r 5a s xe r W,orutofTWe of the SMa n• Ql,(<rA--A CA r c�+tr�•rrklsl 110..tin ii a wnbrs9 br 1141 Ir iikl Fint; j'tafi",Ii +rbs ae f Fdlha•Ut,S+r}K>ts a;e ra If•r W„ww d a»ur,nb 49010'roIa uaugsl W eje Cara,rtaa,Jn 1+a6:m aoGY1411*ruin Use viral tin aFWv1"J,(,weep Lry If,WW- li,ga FJCIu.,y A.Vs j,tar+a t.+b FdU«up 5-.t.,:r,t pu,Gu'++W Oro ,�'d ll+e e V darca w0 fit W.of..ii do r aro not ire ire pwposm o"nrcductsm rm,aky csurt,al oral on-u rescue Fir Cls¢-c cf Ilror trm tiu in In&no—act agry w-wt ttwy are ral Io,Iho v,E ws at p-oiu:tcri LlwiN c xdrnl ra do n7,riise.n ilia Gmx cl Ihnr Ot4-, ne+ in t�s nnwM!- Intertek Testing Services NA Inc- lntertet Testing Services NA Inc. 545 East Algonquin Rood,Arlirbgton Heights,IL 60005 545 East Algmiquin Road, Aslington Heights,IL 600D5 Telephone goo-345-3851 or 847-439-5667 Fax 312-283-1672 Talepht)ns 8,00-345-8851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, ClampingfRetention Devices,and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping)Retention Devices,and Ground Lugs for Use with Flat- Plate Photovoltaic Modoles and Panels[UL 2703,2015 Bd.1+R:24Mar2021] Standard(s): Plate Photovoltaic Modules and Parcels[UL 2703:2015 Ed,1+R:24Ma60?1] Standard is), PV Module and Pane]Racking Mounting System and Accessories(C$A TIL No.A-40.20203 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-4CI;20201 Product. Photovoltaic Mounting System,Sun Frame Microrail Installation Guide,PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrall Installation Guide, PUB2423MAY10 Brand Name: Unirac Brant! Name: Unirac Models: Unirac SFM Models; Unirac SFM ATM Issued: 17-May-2023 ATM for 102393982LAX 002 Page 2 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 1 of 4 or Repo Eo 16_J 15 n -=an,rdnranla y DRAWING NUMBER: E[7 18:!76+,1.J.,I.:L1e'21 hLmdnbory �C] SV BLUE RAVEN tntertek `0LAF, AUTHORIZATION TO (MARK tnkC'rtc'k AUTHORIZATION TO MARK Total Quakty.Assured. Tonal Q"Ry.Assured This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report- This authorization also applies to multiple listee rnodei(s) identified on the correlation page of the Listing Report. Report- This document is the property of Interlek Testing Services and is net transferable. The certification mark(s) may be This document is the property of Inlertek Testing Services and is not transferable. The cerlikation mark(s) may be applied only at the location of the Party Authorized To Apply Mark: applied only at the location of the Party Authorized To Apply Mark, Applicant: Unirac, Inc Manufacturer. Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE Address: Address: Aibuquerque. NM 87102 Address. A1bugUerque, NN4 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest,CA Report Issuing Office- Intertek Testing Services NA. Inc.. Lake Forest. CA r Control Number: 5019851 Authorized by: �brv>' Control Number: 5021866 Authorized by: for L r0atthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C0TV Us C US ,moo Intertek Intertek This document supersedes all previous Author za ions to Mark for the doted Report Number, This document supersedes all previous Authorizations to Marts for the noted Report Number. The h:Yt,��Se�,Ili 1516rt n the r•:tuy+e irne�I c�,�.;ra-��tix,u ar,e Go'•-lad Y�:,cs`ri Iq 1'fe G,.�1f`rfYypr.ry:werrwnl lnhras, InMngF AM r,I t�.nl Itb-1Nk�i rtn.;YrtFin1Y"I u DWry it Thh AAA :Zex to FAWk.a I:,.Inx pr,¢4Ww,rtm c11nk, I W14 is G•,-r.vwf lr r•.vm,In r" age!r+e'l brlw,e..-Imwl0, i?•,,I rr+im 3 wml Iieinuy we I MKLW 10 iho a!r*-s and r_trbfrrn[a rrn✓,r!trrK�r.In!nrhik 6771-rrfe•e no 4;1"If to Nrr"P414Y'�r lam to Inc CNr a,n aeoxdwKe WAPI ltw sFeaTenL In,a,vy 1,0r*e-Pi4-A CN dx-iWJ0 DIXA"'IX 0 limiM la Yt lom-e a"condoo rb of 9"apme"wrL IMOO,aawmFs Inn:abliti In a'TM M`ly L�+r Ihin 4a Ce G�e•n m a zx�-.<'rC+lha u.7f n"5`^t�r aril t:ga et.vi ,C��timYab CAX W' ,F" by the um of IAx AutfKm:atbin tip Mad,Only the G5enl c of ragrelufrm of,N&Aufrxa atxu Io A9a-i and trim rml y In•e wwetY L�sp 0 hllaAek y GMil:;sr•.t+'f rrfafk ir. by ev,I-Isn o7 rtlL Autwazt—la Mal Orly"CLCct s a,shortxa4 le Pornit oopfrN of 6s7Y AL ct Ihic Ajlwaabr to MQA and IIK�rxllf'�n ris s+'d�7'-�:sa o'swr!-aeT'S r WIIK71:Gn Hulk I� ,tlRri'Ifw'1]G WVAI7.fY55 fakd Cat In-.b,gh5b1'fonl we In rim AufteuAta7-,m Mwl.Anf hrarw Ical al 6-1111nnJ t%MT P lit_""e f-60 L`f aa5 1 rhSLCSby LYi dM(L47drJJr`i Ills]eel N5�A J(frM11-der'dr,a,n Q`-t/uA![rCillilt IP.!A$- ful.I law o P I Merfnk M19 w ao f i�41 Ju.c.^:..t,mnl:,C1!Nstb:rtl:r Yikl anco (J ti't, ,J n`yal f.et oe C:vv.aJ n wTUlb bf ItV7MN-Imti el FinYX+!Ae tk-SrJrfm',t-Hite foSo+i:S9rvtsa era 1�Ilrc G-Ilpr.�T.�Ir6Tlrnlq appr�ala ueayo of 9+e Dl*tTKx5ifs11 eN fin at[or�an:i will,IYw fnt lro aF'K'Ood r•w,IlvO laY V"M''.ch.(tiGnl Gec1:xY%cevaertwrlS o,A Ga4or c$r'rue e,e Fw Uin ju'Pa-A oI eeaunni AIPI�Fr'91e u-atia�w[:eN fire b:r+rt-a•r,��a✓�':IaIKN xllh tl'M aa'Iw1rf1M1,m-Yi nrn rid sir Yf6 FuIW%M of Ia,:dur~ifln 7�1nr uTlyd mJ x In51 rlNti�.k n LMrI of InW r"hpncns In IT,,resL�L-- aYYr-wJ t-,ft am reA 6x nt C+ai.icbm 41 71RY r Mrd ana M rKA Clem of f M,r ou.;Q'I 6In In.respec Interiek Testing Services NA Inc Intertek Tesling Servioes NA Inc. 545 East Algonquin Road,Arlington Heights IL W005 545 Easl Algonquin Road, Arlington Heights,IL 6OW5 Telephone 804N15-3651 or 847439-5667 Fax 312-2a3-1672 Telephpne WD-345-31351 or 847-139-5567 Fax 312-283-1672 Mounting Systems,Mounting Devices, Clam pinglRetention Devices,and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, CtampinglRetention Devices,and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed,1+R:24Mar2021] Standards): Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed,1+R:24l,Aar2021j PV Module and Panel Racking Mounting System and Accessocies[CSA TIL No.A-40:20201 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No. A-40,2020) Product: Photovoltaic Mounting System, Sun Frame MicroraH installation Guide,PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide,PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SF'M ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued: 17-May-2023 FC ED 163�15 I1-JuI-?aZ7i dtnMi[irY, DRAWING NUMBER: SS Lntertek ListingConstructional Data Report (CDR) Lntertek Listing Constructional Data Report (CDR) BLUE RAVEN Total Quality.Assured. Total Quality.Assured. 1.0 Reference and Address 1.0 Reference and Address Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 Report Number 102393982LAX-002 Original 11-A r-2016 Revised: 5-Oct-2022 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use Email Standard(s) with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:2020] Applicant Unirac, Inc Manufacturer Address 1411 Broadway Blvd NE Address Albuquerque, NM 87102 Country USA Country Contact Klaus Nicolaedis Contact Todd Ganshaw Phone 505-462-2190 Phone 505-843-1418 FAX NA FAX Email klaus.nicolaedis@unirac.com Email toddg@unirac.com Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 5 Address Country Contact Phone FAX Page 1 of 138 Page 2 of 138 This report is for the exclusive use of tM.enewt.Client and is provided pursuant to:he agreement behveen In artek and ots Client Inleetk s resporm4w4y and This repot rs for the exdusrvO u-.e Of tmertek's Client and K provided pursuant to the agreentdt between Inteentek and its Client Intertek s responsaaay and Law.y are limited to the terms and conditions of the agreement iniortek:ks,umes no liabruty to any patty, other than 10 the Client in ac=danoo with the irab:ey are imuted to the terms and conclions of the agreement htor*k assumes no tiabIfity to any party. Other than to the Client in accordance With the a;<eement,for any loss,expense or damage occas+oneo by the use oX this report Only the Chen is authorized to permit OcpywV or distnW)on of tits report and agreemenl,for any loss expense or damage occas-ored by the use of this report Only the Client rs aulhorized to perms copying or distribution of ins report and than only.n its entirety.Any use of the 1Mtnnek name or One ear Its marks Ion the Sale Or adyertisament of the level material product of se-roe must first be then only in its entxety Any use of the L-Aenek name or one o e its marks for the sate or adyertisemeril of the tested material, product or service must first be DRAWING NUMBER: approved In wntng by uttenex The cioservat ons.and test results in rho report are relevant only to the sarnpte tested Th,s report lay dsell does nor ne imply that e approved in wnbrlg by trrtenek The observatans ant!test results in ttks report are relevant only to the sample tested This report by rtsetl does not imply that the /� /� mazer of product,or sery ce.s co has r.er been under an tntertek certif GObor pro am material product.or service is Or has ever be6n under an Irnertek c ertifraMrt Program l Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-Apr-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 Unirac, Inc Revised: 5-Oct-2022 BLUE RAVEN Unirac, Inc 2.0 Product Description 2.0 Product Description Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Models Unirac SFM Brand name Unirac Model Similarity NA The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System.This system is designed to provide bonding and grounding to Fuse Rating: 30A photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider,outlined in section 4 of this report.There are no rails Module Orientation: Portrait or Landscape within this product, whereas the 3"Micro Rail, Floating Splice, and 9"Attached Splice Maximum Module Size: ftz electrically bond the modules together forming the path to ground. UL2703 Design Load Ratting:ang: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket.The bonding pin of the Micro Rail when bolted and torqued, penetrate Increased size ML test: the anodized coating of the photovoltaic module frame (at bottom flange)to contact the metal, Maximum Module Size: ftz creating a bonded connection from module to module- UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG355S2W-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating:46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope revision in effect in the jurisdiction in which the project resides. Any local electrical codes must LG395N2W-A5, be adhered in addition to the national electrical codes.The Grounding Lug is secured to the LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. photovoltaic module, torqued in accordance with the installation manual provided in this Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" document. IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Other optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same Certifications, & Increase SFM System UL2703 Module Size: engage cable. Maximum Module Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5"gap between the bottom of the module and the roofs surface See section 7.0 illustractions# 1, 1a and 1b for a complete list of PV modules evaluated with these racking systems Other Ratings INA DRAWING NUM BER: ED 16.3 15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory J Aq1Z)LEV -1117/tzY Kq Permit#: 6061 Permit Date: 07/01/24 Permit Type: SOLAR INSTALLATION Project Name: Eileen Beers PV Applicant Name: BRS Field Ops, LLC Applicant Address: 1403 N Research Way Applicant, City, State,Zip: Orem Contact: BRS PERMITTING Phone: 3854820045 Email: permitting.department@blueravensolar.com Scope of Work: 6.3 kW PV Solar Panel Installation on Roof Valuation: 39725.00 Square Feet: 315 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: Permit Expires: Form Permit Type: SOLAR INSTALLATION Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 910 01089200002000 17322 84TH AVE NE CORNERSTONE UNDEVELOPED HOMES NW LLC (VACANT)LAND Contractors Contractor Primary Contact Phone Address Contractor Type License License# BRS Field Ops,LLC 1403 N Research CONSTRUCTION UBI 604 276 519 dba Blue Raven Solar Carson Campbell 385-482-0045 Way CONTRACTOR BRS Field Ops,LLC 1403 N Research CONSTRUCTION L&I BRSFIF0820N3 dba Blue Raven Solar Carson Campbell 385-482-0045 Way CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 07/09/2024 SOLAR INSTALLATION BUILDING In Review Fees Fee Description Notes Amount Building Plan Review Table 4-2 $529.65 Credit Card Service $15.89 Total $545.54 Attached Letters Date Letter Description 07/01/2024 Wcb Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 07/04/2024 XBP Con£ 203997144 $529.65 47/04/2024 BRD Permitting 203997144 Hannah Hardwick $15.89 Outstanding Balance $0.00 Notes Date Note Created By: 07/09/2024 Hard copies received. Kristin Foster 07/03/2024 Applicant provided a valuation of$39725.00 Kristin Foster Uploaded Files Date File Name 07/01/2024 21312781-20240701 BLD6061 BngineerLetter.pdf 07/01/2024 11312782-20240701 BLD6061 Plans.pdf 07/01/2024 21312783-20240701 BLD6061 Apnlication.pdf CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17322 84TH AVE NE Permit#: 6061 Parcel#:01089200002000 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:6.3 kW PV Solar Panel Installation on Roof Valuation:39725.00 OWNER 4W APPLICANT CONTRACTOR CORNERSTONE HOMES NW LLC BRS Field Ops,LLC BRS Field Ops,LLC dba Blue Raven Solar PO BOX 14424 1403 N Research Way 1403 N Research Way MILL CREEK,WA 98082 Orem Orem,UT 87097 3854820045 385-482-0045 LIC:604 276 519 EXP:07/31/2025 LIC:BRSFIF0820N3 EXP:08/23/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: SOLAR INSTALLATION CODE YEAR: STORIES: I CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 07/29/2024 ��� �� 07/29/2024 Applicant Si ature Date Building Official Date CONDITIONS ADHERE TO THE APPROVED PLANS.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES —=MEW Date Description Fee Amount 07/29/2024 Building Plan Review $529.65 07/29/2024 Credit Card Service $15.89 07/29/2024 Processing/Technology $25.00 07/29/2024 Building Permit $810.65 07/29/2024 Credit Card Service $25.07 Total Due: $1,406.26 Total Payment: $1,406.26 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail From: Ameresia Lawlis To: Kristin Foster Subject: FW:Cancellation&Refund Request-17322 84th Ave NE-6061 Date: Thursday,August 15,2024 10:06:58 AM Attachments: Outlook-oaa42fao.ona imaae001.Dna Sincerely, %wAmeresia Lawlis Arlington Community&Economic Development 18204 59th Ave NE,Arlington,WA 98223 O:360.403.3548 alawlis(@arlin tonwa.gov I www.arlin tonwa.g_ov Note: Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act. From: Permitting Department<permitting.department@blueravensolar.com> Sent:Thursday,August 15, 2024 8:48 AM To:Shared-VM-CED<Teams-VM-CED@arlingtonwa.gov> Subject:Cancellation &Refund Request-17322 84th Ave NE-6061 This message is from an External Sender This message came from outside the City of Arlington Hello, Our customer has cancelled and will not be going solar with us at this time. No work has been performed. I am requesting the project be closed out on your end and for a payment refund to be issued, if at all possible. • 6061; 17322 84th Ave NE,Arlington,WA 98223 Please let me know if you need any additional information to process this. If a refund is available and you are sending it via check, please send to the following address: 1403 N Research Way Building J, Orem, Utah 84097. Please make the check to BRS Permitting Best, Lacy Holliday Permitting Department BLUE RAVEN 385.482.0045 SOLAR permitting.department@blueravensolar.com CONFIDENTIALITY NOTICE:This message is confidential and maybe privileged.Please notify the sender immediately by reply email if you have received this email by mistake and then delete it and any attachments thereto from your system. Permit#: 6061 Permit Date: 07/01/24 Permit Type: SOLAR INSTALLATION Project Name: Eileen Beers PV Applicant Name: BRS Field Ops, LLC Applicant Address: 1403 N Research Way Applicant, City, State, Zip: Orem Contact: BRS PERMITTING Phone: 3854820045 Email: permitting.department@blueravensolar.com Scope of Work: 6.3 kW PV Solar Panel Installation on Roof Valuation: 39725.00 Square Feet: 315 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 07/29/2024 Permit Expires: 01/27/2025 Form Permit Type: SOLAR INSTALLATION Status: VOID/WITHDRAWN Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CORNERSTONE 910 01089200002000 17322 84TH AVE NE UNDEVELOPED HOMES NW LLC (VACANT)LAND Contractors Contractor Primary Contact Phone Address Contractor Type License License# BRS Field Ops,LLC Carson Campbell 385-482-0045 1403 N Research CONSTRUCTION UBI 604 276 519 dba Blue Raven Solar Way CONTRACTOR BRS Field Ops,LLC Carson Campbell 385-482-0045 1403 N Research CONSTRUCTION L&I BRSFIFO820N3 dba Blue Raven Solar Way CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 07/09/2024 SOLAR INSTALLATION BUILDING Approved Fees Fee Description Notes Amount Building Plan Review Table 4-2 $529.65 Credit Card Service $15.89 Processing/Technology $25.00 Building Permit Table 4-1 $810.65 Credit Card Service $25.07 Total $1,406.26 Attached Letters Date Letter Description 07/29/2024 Building Permit 07/01/2024 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 07/04/2024 XBP Conf: $529.65 203997144 07/04/2024 BRD Permitting 203997144 Hannah Hardwick $15.89 07/19/2024 XBP Con£ $835.65 205273788 07/19/2024 205273788 Ameresia Lawlis $25.07 Outstanding Balance $0.00 Notes Date Note Created By: 08/15/2024 Received an email from the applicant that the permit is withdrawn. Kristin Foster 07/09/2024 Hard copies received. Kristin Foster 07/03/2024 Applicant provided a valuation of$39725.00 Kristin Foster Uploaded Files Date File Name 07/29/2024 21789648-20240717 BLD6061 ApprovedPlans.pdf 07/01/2024 21312783-20240701 BLD6061 Application.pdf 07/01/2024 21312781-20240701 BLD6061 EngineerLetter.pdf