HomeMy WebLinkAbout19817 74th Ave Ne_BLD6058_2026 i FIRE SPRINKLER PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: ❑ New Installation ❑ System Modification ❑ Phased Installation Property Address. 19817 74th Suite No.: Project Valuation: 4892.00 Lot#: Parcel ID No.: 2844867 Preferred Contact: ❑ Owner ❑Applicant ❑ Contractor Project Description: modify existing fire sprinkler system to protect within the new cooler Owner Name: Himalayan Dog Chew, LLC Phone No.: Email Address: Cell No.: Mailing Address: 505 Fifth Ave 25th Flc city: New York State: NY Zip: 10017 Applicant Name: Commercial Fire Protection, Inc. Phone No.: 360 848-9093 EXT 1 Email Address: della@cfirepro.com Cell No.: Mailing Address: 17199 Bennett Rd. city: Mount Vernon State: WA Zip: 98273 Contractor Name: Same as Applicant Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: ❑ Complete and Scaled Plans ❑ Hydraulic Calculations ❑ Equipment Specifications for Each Fire Sprinkler Permit Application ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ✓❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 125.00 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $600.00 + 1 $ 1 = $ Hydraulically Designed Systems Yes ❑ No 0 Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ 125.00 NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $625.00 + 1 $ _ $ Hydraulically Designed Systems Yes ❑ No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ❑ HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I - new or existing x $150.00 = $ Class II - new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS (105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ 125.00 PLAN REVIEW FEE $ 100.00 Processing/Technology Fee $25.00 TOTAL $ 250.00 I hereby certify that I am the ❑ Owner, ✓❑Applicant, ❑ Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. �eeea. �eee;.►1,�e�, Della Dellinger 06/28/24 Signature Print Name Date SAVE PRINT REV2022 Page 3 of 3 r1"TEE j 1"PLUG 201-0" VIKING DRY SPRINKLER BRANCHLINE MOUNTED INSULATING BOOT ASSEMBLY 22087M/W TO TOP OF COOLER/FREEZER PANEL y 5'-0" 10'-0" 5'-0" It COOLER/FREEZER CEILING DRY PENDENT I A=18" CD 4) 7 1.511 x 111 DRAIN CAP DRY PENDENT DETAIL LO In to 1.5 � 1.5 10-0 2-6 ro ro 1-5/8"x 1-5/8"x 4"LONG UNISTRUT us WITH UNISTRUT CLAMP SECURE TO WALL GIRT WITH(2)1/4"x 1"TEK SCREWS AND 1/4"x 1"FENDER WASHER o NEW COOLER r 9 N EJ 3 x1.511MTxG MEN= r r 0 COOLER/FREEZER CEILING 1.5 1.5 3" BRANCHLINE AT ROOF 2-6 c co HANGER IU I S co o r SUSLO LO (9 SS 4� �CO WOOD JOIST 3/8"SAMMY GST 201 3/8"ATR HANGER RING N COOLER SPRINKLER PLAN HANGER 'SS' 0 2 4 SCALE 1/2-1'-0" -------777 GTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Mike Hinton 7358-0100-C Level Expires Commercial Fire Protection,Inc. COMMEFP132MM Digitally sign b 24 i Mike Hinton Hint i Date::2024.06.28 09-97-03-n7'nn' `Signattu�--------------Date--j HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS CONTRACT WITH COMMERCIAL FIRE PROTECTION, INC. SYM SIN# MANUFACTURER TYPE MODEL Flry s° `"�Flry s",`ox A.% g1:1 ' AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION PIPE SS SAMMYSCREW-SEE DETAIL ON SHEET I OF B�oD BOTTOM OF DECK EOTTO.OF SEA STRUCTURE NCENTELINEFINCHESO REFERENCED HIMALAYAN DOG CHEW LLC 17199 BENNETT ROAD VK176 VIKING DRY SSP OR S&S WHITE WHITE 5.6 1" 286" 4 BOJ BOTTOM OF JOIST BOD MT VERNON,WA 98273 US UNISTRUT-SEE DETAILON SHEET I OF ROP BOTTOM OF PURUN 1 2-WAY EARTHQUAKE SWAY BRACE 19817 74TH AVENUE NE LICENSE#COMMEFP132MM ROT BOTTOM OF TRUSS CTS CUT TO SUIT NUMBER INDICATES TYPE ARLINGTON,WA 98223 PHONE: (360)848-9093 FAX: (360)848-1072 FO FIELD ORDER IPOW INSIDE FACE OF wAu 2 4-WAY EARTHQUAKE SWAY BRACE OFOW OUTSIDE FACE OF WALL NUMBER INDICATES TYPE NAB NOAUTOMATIOSPRINKLERB HANGER LOCATIONMANAGER: ■ HIMALAYAN PET SUPPLY NEW COOLER TI UNO UNLESS NOTED OTHERWISE T PROJECT HOONSEO HWANG ELEVATION ABOVE REFERENCED PHONE:360-995-8110 19817 74TH AVENUE NE POINT IN FEET AND INCHES EMAIL:hhwang@primalpetgroup.com O HYDRAULIC CALCULATION NODE SUPERINTENDENT: ARLINGTON,WA 98223 mil! FLEXIBLE COUPLING PHONE AUTHORITY HAVING JURISDICTION :CITY OF ARLINGTON FAX DESIGNER DATE SHEET JOB NO. �� RIGID COUPLING KEY PLAN MIKE HINTON 6/28/24 1 OF 1 2024528 �1„TEE --1"PLUG 20'-0" VIKING DRY SPRINKLER BRANCHUNE MOUNTED INSULATING BOOT ASSEMBLY 22087MIW TO TOP OF COOLER/FREEZER PANEL COOLER FREEZER CEILING ------ �_...-.. DRYPENDENTJ 1.5"x 1"DRAIN CAP DRY PENDENT DETAIL L 1.5 10 0 v 2-6 0 �� 1-5/8"x 1-5/8"x V LONG UNISTRUT US 4 WITH UNISTRUT CLAMP i SECURE TO WALLGIRTWITH(2)1/4"x1^TEK SCREWS I rAND 1/4"x 1'FENDER WASHER a4 NEW COOLER of o t kFl 3"x1.5"MTxG x r� v O' ,, � COOLER,FREEZER CEILING 1.5 1 5 3"BRANCHLINE AT ROOF I I 10-0 2-6 to HANGER'US' i ; to U) Lg US v1 _9 { Up W i I I v i 1 1 I SS � II 70 �..� —WOOD JOIST 3/9"SAMMY GST 20� �---3/8"ATR CITY OF ARLINGTON HANGER RING BUILDING DEPARTMENT N — 'T -- APPROVED�C(� COOLER SPRINKLER PLAN HANGERS DA 1D0}i.§NGEs aU HOR,2PD UNLESS APPEOVEO-Ge-HE BUILDING INSPECTOF2 RECEIVED JUN 2 9 2CIL4 1 WASHINGTON STATE 1 1 CERTIFICATE OF COMPETENCY 1 1 FIRE PROTECTION SPRINKLER SYSTEMS 1 1 Mike Hinton 1 7358-0100-C Level3 Expires Commercial Fire Prote0'00,Inc. COMMEFP132MM {.Digit ally Sign 4 1 Mike Hinto Pete 202405.28 ��m nTnn 1 Date 1�J HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS '�—TRACT wlm M SIN! Aim E MODEL EME NE ETOHEFERENCEO NO DATE REASON FOR REVISION COMMERCIAL FIRE PROTlICTION,INC. SE SAIAMY SCREW-SEED—ONSHEET-1 L~-`l IST c INCHES HIMALAYAN DOG CHEW,LLC n,se BENNETT ROAo VK1]6 NKINO Dny SSP OR S85 WHf1E WHITE S.6 1' 28C NT VERNON,WA B62]3 US UNISTRUT-SEE DETAIL ON SHEET,OF =v 1 :HQ SWAY BRACE 1981774TH AVENUE NE LICENSE NON, FP132MM Imu ARLINGTON,WA 98223 PRONE:(B6n)8ns-sms Fax:(W)B4B-,on 4 WAv ANOHOnAKC 9V�AV BPpCE NUMBFA O..nT B rVPL LN HANc' cA-'.N PROJECT MANAGER:HOONSEOHWANG ■ HIMALAYAN PET SUPPLY NEW COOLER TI ELEVA—:,BOv'RE:ERENCEO PHONE::::380.995,8110 alNr IN FEL,AnI:�NCRcs EMAIL:NNwang@primelpetgmup.com 19817 74TH AVENUE NE Q NrowWUC CALCU—ION NODE SUPERINTENDENT: ARLINGTON,WA 98223 —NF— FtEI6elE couqurvc PHONE: —{� gIO10 n9BPLING AUTHORITY HAVING JURISDICTION:CITY OF ARLINGTON F'ix KEv PUN DasICNER DATE sNEET roe ND. MIKE HINTON 6/28/24 i OF 1 2024528 / I Permit#: 6058 Permit Date: 06/28/24 Permit Type: FIRE SPRINKLER Project Name: Himalayan Pet Supply New Cooler Applicant Name: Commercial Fire Protection, Inc. Applicant Address: 17199 Bennett Rd. Applicant, City, State,Zip: Mount Vernon,WA 98273 Contact: Della Dellinger Phone: 360 848-9093 EXT 113 Email: della@cfirepro.com Scope of Work: Modify Existing fire sprinkler system to accommodate new cooler Valuation: 4892.00 Square Feet: 400 Number of Stories: 1 Construction Type: 111A Occupancy Group: B; Business ID Code: CIC Permit Issued: Permit Expires: Form Permit Type: FIRE SPRINKLER Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GAYTEWAY 300 INDUSTRIAL/ 31051400200700 19817 74TH AVE NE BSP#202012225005 BUSINESS PARK, MANUFACTURING LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Fire CONSTRUCTION COA 601 011 373 Protection,Inc Della L Dellinger 360-848-9093 17199 Bennett Rd CONTRACTOR Commercial Fire CONSTRUCTION Labor& COMMEFP132MM Protection,Inc Della L Dellinger 360-848-9093 17199 Bennett Rd CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 06/A/2024 FIRE SPRINKLER BUILDING In Review Fees Fee Description Notes Amount Enter 1 if permit is for:fire alarm,or fire $200.00 Web Only-Fire System Plan Review sprinkler Total $200.00 Attached Letters Date Letter Description 06/28/2024 Web Fonn-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 06/28/2024 XBP Conf: $200.00 203554208 Outstanding Balance $0.00 Uploaded Files Date File Name 06/28/2024 21269749-20240628 BLD6058 Plans.pdf 06/28/2024 21269750-20240628 BLD6058 Application.pdf CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 - BUILDING PERMIT 19817 74TH AVE NE Permit#: 6058 Parcel#:31051400200700 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Modify Existing fire sprinkler system to accommodate new cooler Valuation:4892.00 APPLIC I CONTRACTOR 1 GAYTEWAY BUSINESS PARK,LLC Commercial Fire Protection,Inc. Commercial Fire Protection,Inc P.O.BOX 1727 17199 Bennett Rd. 17199 Bennett Rd BELLEVUE,WA 98009 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360 848-9093 EXT 113 360-848-9093 UC:601011373 EXP:03/31/2025 LIC:COMMEFP132MM EXP:08/16/2024 MECHANICAL CONTRACTOR . PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2021 STORIES: I CONST.TYPE: 111A DWELLING UNITS: 0 OCC GROUP: B;Business BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL . The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this pennit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 7/17/24 �lGl.� �� 07/17/2024 Applicant Signature Date Building Official Date CONDITIONS ADHERE TO THE APPROVED PLANS.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES ' Date Description Fee Amount 07/17/2024 Web Only-Fire System Plan Re\iew $200.00 07/17/2024 Processing/Technology $25.00 07/17/2024 Fire Sprinkler System $125.00 Total Due: $350.00 Total Payment: $350.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 6058 Permit Date: 06/28/24 Permit Type: FIRE SPRINKLER Project Name: Himalayan Pet Supply New Cooler Applicant Name: Commercial Fire Protection, Inc. Applicant Address: 17199 Bennett Rd. Applicant, City, State, Zip: Mount Vernon,WA 98273 Contact: Della Dellinger Phone: 360 848-9093 EXT 113 Email: della@cfirepro.com Scope of Work: Modify Existing fire sprinkler system to accommodate new cooler Valuation: 4892.00 Square Feet: 400 Number of Stories: 1 Construction Type: 111A Occupancy Group: B; Business ID Code: CIC Permit Issued: 07/17/2024 Permit Expires: 01/13/2025 Form Permit Type: FIRE SPRINKLER Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GAYTEWAY 300 INDUSTRIAL/ 31051400200700 19817 74TH AVE NE BSP#202012225005 BUSINESS PARK, MANUFACTURING LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Fire Della L Dellinger 360-848-9093 17199 Bennett Rd CONSTRUCTION COA 601 011 373 Protection,Inc CONTRACTOR Commercial Fire Della L Dellinger 360-848-9093 17199 Bennett Rd CONSTRUCTION Labor&COMMEFP132MM Protection,Inc CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 07/30/2024 FS07.FIRE loam fire sprinkler final 07/31/2024 07/31/2024 BUILDING Approved SPRINKLER FINAL Plan Reviews Date Review Type Description Assigned To Review Status 06/28/2024 FIRE SPRINKLER BUILDING Approved Fees Fee Description Notes Amount Enter 1 if permit is for:fire alarm,or fire Web Only-Fire System Plan Review sprinkler $200.00 Processing/Technology $25.00 Fire Sprinkler System Commercial NFPA 13/13R $125.00 Total $350.00 Attached Letters Date Letter Description 07/17/2024 Building Permit 06/28/2024 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 06/28/2024 XBP Conf: $200.00 203554208 07/17/2024 XBP Conf: $150.00 205063262 Outstanding Balance $0.00 Uploaded Files Date File Name 07/17/2024 21648539-20240715 BLD6058 Appr2vedPlans.pdf 06/28/2024 21269750-20240628 BLD6058 Application.pdf