Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17704 38th Dr Ne_BLD6507_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17704 38TH DR NE Permit#: 6507 Parcel#:00598900004000 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Remove and replace electric water heater Valuation:7500.00 - APPLICANT CONTRACTOR CARSEN WARREN Washington Water Heaters,Heating and Washington Water Heaters Heating&Air Air Inc 17704 38TH DR NE 6622 232nd AVE E PO Box 5158 ARLINGTON,WA 98223 Buckley,WA 98321 Kent,WA 98064 4258834871 425-883-4871 LIC:604 846 080 EXP:01/31/2026 LIC:WAWATV 1780BO EXP:01/18/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL PLUMBING CODE YEAR: 2021 STORIES: 1 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: _ PERMIT APPROVAL� _ The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 5/29/25 �1 •�� 05/16/2025 Applicant Signature Date Building Official Date - CONDITIONS ■ Adhere to approved appliances.Permit shall be onsite for inspection.Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/16/2025 Processing/Technology $25.00 05/16/2025 Inspection $75.00 05/16/2025 Plumbing Base $25.00 05/16/2025 Water Heater(Tank) $25.00 Total Due: $150.00 Total Payment: $150.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail RESIDENTIAL PLUMBING APPLICATION Community and Economic Development City of Arlington• 1B204 59th Ave NE•Arlington,WA 98223 a Phone(360)403-3551 This application islfor new,repaired,altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. Type of Permit: ❑ New Installation ❑ Addition 0 Alteration ❑ Repair Property Addres� 17704 38th DR NE Project Valuation: 7500 Lot#: 40 Parcel ID No.. 0059890000400 Preferred Contact: 0 Owner M Contractor Project Description:Remove and replace electric water heater Owner Name: Warren Carsen Home No.: 4255518016 Email Address: rnarycarsen@gmaii.com Cell No.: Mailing Address: 17704 38th DR NE City.. Arlington State: WA Zip: 98223 Contractor Nam(,.: Washington Water Heaters Office No.: 4258834871 Email Address: Wawahvac@gmail.com Cell No.: Mailing Address 6622 232nd AVE E City: Buckley State: Wa Zip: 98321 L&E Contractor License Number: wawatwh780bo Expiration Date: 1/18/26 • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves [PRV) • Cross-Conner ion-Control may be required Proposed Interior Water Piping Size: ❑ 1h" ❑ r'A ❑ 3/4" ❑ 1" Proposed Interior Piping Material: ❑CPVC ❑ Brass ❑ Copper ❑ PEX-AL-PEX ❑ PEX ❑ Galvanized Steel ❑ Other Proposed Exterior Water Piping Size: ❑ lh" ❑ S/V ❑ 3/4" ❑ 1" ❑ 11h" ❑ 2" Proposed Exterior Piping Material: ❑ PVC ❑PE ❑ Copper ❑ PEX-AL-PBX ❑ PEX-AL-PE ❑ PEX ❑ Other Proposed Drain- aste-Vent(DWV) ❑Schedule 40 ABS DWV ❑ Copper ❑ Galvanized Steel ❑ Cast Iron Material: ❑ Schedule 44 PVC DWV ❑ Brass ❑ other Proposed Drain- ante-Vent(DWV) Piping Size: ❑ '/z., ❑ $Ja" ❑ 3/4" ❑ 1., ❑ 1r��, ❑ 2�. ❑ 3�� 04„ PLUMBING PERMIT FEES (per fixture) Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees X $75.00 = Alteration re air piping x $15.00 = Backflow Assemblyx $25.00 = Base PlumbingFe _ 1 x $25.00 = $25.00 Bath Shower Combo x $15.00 = Building Main waste x $25.00 = clothes Washer z $ 15.00 - Dishwasher X $15.00 - REV03.2022 Page 1 of PLUMBING PERMIT FEES (per fixture) Drinking Fountain X $15.00 = Floor Drains x $15.00 = ---- -- ---- Grease Interceptoi x $75.00 = Grease Trap x $25.00 - Hose Bibh X $1.5.00 - Icemaker/Refriget atar x $15.00 Irrigation-per mc ter x $2S.00 = Kitchen Sink&Dis 3osal x $15.00 Laundly Tray x $15.00 = Lavatory x $15.00 = Med Gas Piping!; inlets/outlets x $60.00 - Med Gas Piping> inlets/outlets(plus s 5 x $5.00 = inlets/outlets) Miscellaneous-re crulated by plumbing code,not x $15.00 = otherwise s ecifie Pretreatment Interceptor x $15.00 = Re-inspection Fee x $75.00 = Roof Drains x $15.00 - Shower(only) X $15.00 = Sink bar,service, etc.] x $15.00 = Toilets x $15.00 = Urinal x $15.00 - Vacuum Breakers x $25.00 = Water Heater 1 x $25.00 MODEL NO.: Pro H80T2RH400-30 Water Heater-Ta kless x $25.00 = MODEL NO.: Permit Fee 25.00 Inspection Fee $7S.00 Processing/Technology Fee $2S.00 Total 125.00 1 hereby certify tha I am the❑owner. QApplicant, ©Contractor-and authorized to sign this application and that the above information is correct and cons tr ction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the St to of Washington,and the City ofArlington.A final inspection and approval shall be obtained when complete. Steve Hyde 5-1 6-25 Signature Print Name Date SINE PRINT REV03.2022 Page 2 uf2 Residential Electric ' Water Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heaters The new degree of comfort® Professional Prestige® ProTerra® Hybrid Electric Heat Pump is the most efficient -- water heater available Efficiency Operation Modes t���1\;ql� • Up to 4.07 UEF reduces operating • Energy Saver \�J cost • Heat Pump • ENERGY STAR®certified • High Demand •Title 24 Compliant(JA13 Ready) o Electric m Performance •Vacation/Away: 2-28 days(or placed / • Delivers hot water faster than most on hold indefinitely) standard electric water heaters— Plus... 60-87 gallons first-hour delivery, depending on model • Premium grade anode rod extends •Ambient operating range:37-1450 F the life of the tank ConnectionsNew!Top is widest in class, offering more heat • Dip tube diffuser reduces sediment and Duct Ready De . pump operation annually; designed to improving efficiency and tank life meet Northern Climate Spec(Tier 4) •3/4" NPT water inlet and outlet; •Quiet Operation 3/4"condensate drain connections Easy Installation • Incoloy stainless steel resistor elements • Universal top and side water connections • Dry-fire protection •Quick access to electrical junction box • Easy access,top mounted washable air filter • Duct ready design .2" Non-CFC foam insulation • Easily replaces a standard electric water heater • Enhanced flow brass drain valve Integration •Temperature and pressure relief valve installed Professional Prestige adjustment and mode management y • Electronic control for easy temperature . Design certified to NSF/ANSI 372 ProTerra Hybrid Electric (Lead Content) •Audible alarm for service alerts Heat Pump • Built-in Wi-Fi powered by EcoNet®* Warranty 40, 50, 65 and 80-Gallon and free mobile app gives users • 10-Year limited tank and parts Capacities control over water heater,allowingfor warranty See Residential Warranty Certificate for complete 208-240 Volt/ 1 PH customizable temperature,vacation information 30 and 15 Amp settings, energy savings and system monitoring at home or away Units meet or exceed ANSI requirements and have Electric been tested according to D.O.E.procedures.Units • Demand Response Ready with built-in meet or exceed the energy efficiency requirements EcoPortTM(CTA-2045 Port) of NAECA,ASHRAE standard 90,ICC Code and all • Easily add leak detection and state energy efficiency performance criteria. C&us 0 prevention with the leak LEED Points=3 sensor and shutoff valve kit (part#SP21265A sold separately) *Wi-Fi broadband internet connection required. See specifications chart on next page. INTEGRATED HOME 07/24 WP FORM NO.HP-400-NO SO Professional Prestige' ProTerra Hybrid Electric Heat Pump Specifications 40 36 PROPH40 T2 RH400-30 702303 30 "3.834,200 60 27 4,500 5,000 21 166 18450 45 PROPH50 T2 RH400-30 702300 30 . , 00 67 27 4,500 5,000 21 185 203 65 59 PROPH65 T2 RH400-30 702302 30 4.05 4,200 76.6 27 4,500 5,000 21 245 289 80 72 PROPH80 T2 RH400-30 702344 30 4.07 4,200 87 27 4,500 5,000 21 261 306 ProTerra 15 Amp 40 36 PROPH40 T2 RH400-15 702293 15 3.45 4,200 46 16 2,250 2,750 12 166 184 50 45 PROPH50 T2 RH400-15 702297 15 3.75 4,200 52 16 2,250 2,750 12 185 203 65 59 PROPH65 T2 RH400-15 702292 15 3.55 4,200 54 16 2,250 2,750 12 245 289 80 72 PROPH80 T2 RH400-15 702295 15 3.70 4,200 67 16 2,250 2,750 12 261 306 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. All units have integrated Wi-Fi control board. It 2"Clearance Needed for T&P Release I F -70 I J ' I H K A C E 0 pCAPACITY NUMBER NMI C hm 01do I No 0 DESCRIPTION DIMENSIONS(SHOWN IN INCHI��. NOMINAL GALLON MODEL 40 PROPH40 62-5/16 1 20-1/4 47 3-5/8 1 39-5/8 1 25-3/8 1 20-1/2 78-7/8 20-1/4 21-3/4 1 64-15/16 50 PROPH50 61-3/4 22-1/4 47 3-5/8 39-5/8 27-3/8 22-1/2 78-5/8 22-1/4 21-3/4 64-3/8 65 PROPH65 64-3/16 24-1/4 49 3-7/8 42-3/8 29-1/2 24-5/8 81-1/8 24-1/4 25-13/16 66-13/16 80 PROPH80 74-3/16 24-1/4 59 3-7/8 42-3/8 29-1/2 24-5/8 91 24-1/4 25-11/16 76-13/16 2 Hybrid Electric Heat Pump Water Heater Installation Guidelines to Provide Optimal Efficiency Heater: Not Ducted Heater: Not Ducted Room size:Smaller than 700 ft3(e.g.Tx 10'x 10'). Room size:Larger than 700 ft3(e.g.Tx 10'x 10'). Requirements:Full louvered door OR two louvers Requirements:No additional ventilation needed. top and bottom.See below. O O Heater: Not ducted Room:Small Closet Requirements:'Air gap under door equal to 18 in (0.75"clearance). Louver must be located the same height on door as the air exhaust on heater. "Heater air exhaust must be positioned towards louver within one foot of door. O O O Air exhaust 24" 12'Max Door Heater: Ducted with inlet OR outlet duct Room size:Any size room Heater: Ducted with inlet AND outlet duct Requirements:Air gap under door equal to 18 in Room size:Any size room (0.75"clearance) Requirements:No additional ventilation needed. ri ,ri O 0 U �® 00 75" ~ 1 24" NOTE.Heat pump water heater will operate in rooms less than 700 ft'down to 450 ft'but at reduced energy efficiency and reduced performance output.Reduced energy efficiency and performance has not been evaluated by Rheem Manufacturing and not recommended for optimal performance of the unit.When unit is operated in a small enclosure,a door or wall with a minimum of 2.3 sq it of louvers is recommended to provide proper air changes for unit function. 3 Residential Electric 1 ,, Water Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heaters The new degree of comfort? Hybrid Electric Heat Pump Accessories List PART NUMBER DESCRIPTION USE FOR AP19134 Leak Sensor Automatic detection of internal and external leaks AS50618A Shutoff Valve Automatic shutoff of water supply to unit SP20882 Earthquake Isolation Kit Installations in seismic regions SP20883 Vibration Isolation Kit Installation on non-concrete floors SP20884 8"Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8"diameter SP20885 7"Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7"diameter SP20886 6"Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6"diameter SP20887 5"Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5"diameter SP20888 8"Collar for Flex Venting Exhaust only to the outside ducting configuration(no inlet duct) SP20889 25'Flexible 8"Diameter Duct Kit For up to 25'of ducting SP20890 8"Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized UPGRADE SP21265A Kit-Automatic Shutoff Valve Assembly Add leak detector,shutoff valve and S.O.V.extension harness for top connection setup Leak Sensor Shutoff Valve Earthquake Isolation Kit Vibration Isolation Kit TiE' .... T� •151. .... irk .. 8"Diameter UL Certified 7"Diameter UL Certified 6"Diameter UL Certified 5"Diameter UL Certified Termination Kit Termination Kit Termination Kit Termination Kit 8"Collar for Flex Venting 25'Flexible 8"Diameter Duct Kit 8"Rigid Elbow Duct Kit UPGRADE KIT(for ProTerra models without LeakGuard only)-Add leak detector and shutoff valve to protect from F water damage=� Leak Sensor&Shutoff Valve Kit In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Roswell,Georgia 30076 • www.rheem.com Brampton,Ontario L6Y OP5 • www.rheem.ca INTEGRATED HOME COMFORT 07/24 WP FORM NO.HP-400-NO SO Permit#: 6507 Permit Date: 05/16/25 Permit Type: RESIDENTIAL PLUMBING Project Name: Warren Carsen Applicant Name: Washington Water Heaters , Heating and Air Inc Applicant Address: 6622 232nd AVE E Applicant, City, State, Zip: Buckley,WA 98321 Contact: Steve Hyde Phone: 4258834871 Email: wawahvac@gmail.com Scope of Work: Remove and replace electric water heater Valuation: 7500.00 Square Feet: 1426 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 05/29/2025 Permit Expires: 11/28/2025 Form Permit Type: RESIDENTIAL PLUMBING Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00598900004000 17704 38TH DR NE CARSEN WARREN FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# Washington Water 6622 232nd AVE CONSTRUCTION COA Business Heaters Heating&Air Jacci Daniels 425-883-4871 E CONTRACTOR License 604846080 Washington Water Jacci Daniels 425-883-4871 6622 232nd AVE CONSTRUCTION L&I WAWATWH780BO Heaters Heating&Air E CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/29/2025 C19.PLUMBING 10/03/2025 09/30/2025 BUILDING Approved FINAL 09/29/2025 R14.PLUMBING 09/30/2025 09/30/2025 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Plumbing Base Permit Fee $25.00 Water Heater(Tank) $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 05/16/2025 Building Permit 05/16/2025 Building Permit 05/16/2025 Web Form-Residential Plumbing Application Payments Date Paid By Description Payment Type Accepted By Amount 05/16/2025 Washington Water 231636893 Hannah Hardwick $4.50 05/16/2025 XBP Conf: $150.00 231636893 Outstanding Balance $0.00 Notes Date Note Created By: 09/26/2025 Sent Expiration notice LaNay Hendrick Uploaded Files Date File Name 09/29/2025 28487317-Inspection Request for City of Arlington Permit#6507.msg 05/29/2025 26347193-2025 BLD6407 IssuedPErmit.pdf 05/16/2025 ca5d575f74cc2blf8dfd547aa7012f82 w. carsen signgd permit application.pdf 05/16/2025 485bed6f3d5lb36el5afd594f4b7a2fD 65 and 80 gallon_heat pump water heater spec sheet.pdf