Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17916 Oxford Dr_BLD6681_2026
i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation Addition/Alteration/Repair ❑ Gas Piping 17916 Oxford DR 16300.00 Property Address: Project Valuation: Lot#: Parcel ID No.: 00893900000500 Preferred Contact: ❑ Owner ❑ Contractor Project Description: like for like furnace replacement and add ac to hvac system Owner Name: Austin Fowler Home No.: Email Address: Cell No.: 4254184191 17916 Oxford Dr Arlington Wa 98223 MailingAddress: City: State: Zi . Contractor Name: Bobs Heating Office No.: 8008403346 Email Address: Ihoneycutt@bobsheating.com Cell No.: 2069390384 Mailing Address: 14148 ne 190th st City: Woodinville State: Wa Zip: 98072 L&I Contractor License Number: BOBSHHA853NQ Ex piration Date: 9/7/25 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ s/s" 713/4" ❑ 1" ❑ 11/2 ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h 1 x $ 15.00 = 15 146SAN036 Air Conditioning Unit> 100 Btu h x $25.00 = Air Conditioning Unit> 500 Btu/hp x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 7 Boiler<100Btu h>3h x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h 1 x $ 15.00 = 15.00 820TB36070 Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit> 500 Btu/hp x $50.00 = Gas Pipin <_5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 mechanical code,not otherwise specified Package Units<_ 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters<_ 100 Btu/h x $ 15.00 = Unit Heaters>100 Btu/h x $25.00 = Variable Air Volume Boxes (part of Air x $ 10.00 Conditioning System) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee 55.00 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 155.00 I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. Lucinda Honeycutt 8/19/25 Signature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 D- pj A.I..Z4-„ A.r ply .00 I Fl 1 �� ��1 i 1 - 1 1 I NfovA Ur 146SAN Preferred TM Series Single-Stage Air Conditioner I with Puron Advance TM Refrigerant 1-1/2To5Tons Product Data Industry leading Features / Benefits Efficiency • 13.8-17.0 SEER2/11.2—14.5 EER2 • MicroChannel Technology refrigeration system • Indoor air quality accessories available Comfort • System supports programmable or standard thermostat controls :1111111111111�I Reliability �111111111111 ' ' Non-ozone depleting,low global warming potential Puron AdvanceTM refrigerant • Scroll compressor �Illlllllllll Internal pressure relief valve IJIIIII Internal thermal overload ,, I:I f�IIIIIIIIIII� Filter drier "''+ii�111111/1 f llll Durability Ill DuraguardTM Protection Package: • Solid,durable sheet metal construction • Louvered coil guard Applications �. 2 • Long—line—up to 250 feet(76.20 in)total equivalent length,up to 200 Pu r on I ntel i Se n se l_ feet(60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more A D V A N C E" T E C H N O L O G Y information.) • Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits. This unit has been designed utilizing Bryant's non-ozone depleting,low InteliSense TM Technology global warming potential Puron AdvanceTM refrigerant. This unit is InteliSense capable when used with an ecobee for Bryant Air conditioners with Puron Advance refrigerant provide a collection smart thermostat with InteliSense technology. InteliSense technology of features unmatched by any other family of equipment. allows for the collection of performance data to be sent to the cloud. Utilizing Bryant's digital tools,dealers can gather system settings and NOTE:Ratings contained in this document are subject to change at any equipment data,with homeowner opt-in,to provide quicker and more time. Always refer to the AHRI directory (www.ahridirectory.org) for efficient service. the most up-to-date ratings information. Limited warranty • 5-year parts limited warranty(including compressor and coil) 10-year parts limited warranty (including compressor and coil) with timely registration* — Equipment must be registered within 90 days of original installation,except in jurisdictions where warranty benefits cannot be conditioned on registration. * Applies to original purchaser/homeowner and not available to subsequent owners except in jurisdictions where applicable laws dictate otherwise. See warranty certificate for complete details and restrictions. 146SAN:Product Data MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7,8,9 10 11 12 1 4 6 S A N 018 0 0 W Product Tier& SEER2 OD Design Major Series Voltage Cooling Feature Special Region Family Refrigerant Type Capacity Feature 1=AC 4=Preferred 6=16.0 S=Single A-Z=Major N=208-230-1 or 018=18,000 BTUH(1.5 Tons) 0=Standard 0=Standard W=Standard SW Series HP SEER2 Stage Series 208/230-1 024=24,000 BTUH(2 Tons) AC with Puron P=208-230-3 or 030=30,000 BTUH(2.5 Tons) Advance TM 208/230-3 036=36,000 BTUH(3 Tons) (R-454B) E=460-3 042=42,000 BTUH(3.5 Tons) Refrigerant 048=48,000 BTUH(4 Tons) 060=60,000 BTUH(5 Tons) oCOME P Ur on Use of the AHRI certified ADVANCE" TM Many indicates a C U S manufacturer's participation in the Quality P rogram Forwrification IS09001 of certification for individual ®saou ^^�•-----� Products,go to www.ahndirectoryorg. CATALOG ORDERING NUMBERS Size Model Number 18 146SAN0180OW 24 146SAN0240OW 30 146SAN03000W 36 146SAN0360OW 42 146SAN0420OW 48 146SAN0480OW 60 146SAN06000W STANDARD FEATURES Features 18 24 30 36 42 48 60 Puron AdvanceTm Refrigerant X X X X X X X SEER2(Range depending on indoor combination) 14.3-17.0 14.3-17.0 14.3-16.5 14.3-16.5 14.3-16.5 13.8-15.5 13.8-16.0 Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line Capability X X X X X X X Low Ambient Capability with Kit X X X X X X X High Pressure Switch X X X X X X X Low Pressure Switch X X X X X X X Compressor Sound Blanket X X X X X X X Louvered Coil Guard X X X X X X X Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 2 146SAN:Product Data PHYSICAL DATA UNIT SIZE 18 24 30 36 42 48 60 COMPRESSOR TYPE Scroll REFRIGERANT Puron AdvanCeTM (R-45413) Factory Charge"lb(kg) 4.2(1.91) 4.7(2.13) 5.5(2.49) 6.9(3.13) 7.2(3.27) 5.7(2.58) 7.9(3.58) COND FAN Forward Swept or Propeller Type,Direct Drive Air Discharge Vertical Air Qty(CFM) 2300 3600 3300 3800 4900 3100 3900 Motor HP 1/12 1/10 1/10 1/10 1/5 1/5 1/4 Motor RPM 800 825 825 825 1100 1100 1100 COND COIL Face Area(Sq ft) 17.7 19.8 22.0 17.7 22.0 17.7 22.0 Fins per In. 25 25 25 20 20 20 20 Rows 1 1 1 2 2 2 2 Circuits 4 4 6 8 9 8 9 VALVE CONNECT.(In.ID) Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 Liquid 3/8" REFRIGERANT TUBESt(In.OD) Rated Vaport 5/8 3/4 3/4 7/8 7/8 7/8 1 1/8 Rated Liquid Line$ 3/8" ..For 15 ft.lineset t.Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. $.See Liquid Line Sizing For Cooling Only Systems with Puron AdvanceT"'Refrigerant tables. Note: See unit Installation Instruction for proper installation. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 3 146SAN:Product Data REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron AdvanceTm Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Table 1—Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit AC with Puron Advancer""Refrigerant Maximum Total Equivalent Length*: Outdoor unit BELOW Indoor Liquid Line Vertical Se Size Liquid Line Diam.(in.) Separation ft(m) Connection w/TXV 05 6-10 11-20 2130 31-40 41-50 51-60 61-70 71-80 (0-1.5) (1.83.0) (3.4-6.1) (6.4-9.1) (9.4-12.2) (12.5-15.2) (15.5-18.3) (18.6-21.3) (21.6-24.4) 1/4 150 150 125 100 100 75 -- -- -- 18000 3/8 5/16 250 250 250 250 250 250 250 225 150 3/8 250 250 250 250 250 250 250 250 250 1/4 75 75 75 50 50 — -- -- — 24000 3/8 5/16 250 250 250 250 250 225 175 125 100 3/8 250 250 250 250 250 250 250 250 250 1/4 30 -- — -- -- — -- -- — 30000 3/8 5/16 175 225 200 175 125 100 75 -- — 3/8 250 250 250 250 250 250 250 250 250 36000 3/8 5/16 175 150 150 100 100 100 75 -- — 3/8 250 250 250 250 250 250 250 250 250 42000 3/8 5116 125 100 100 75 75 50 -- -- — 3/8 250 250 250 250 250 250 250 250 150 48000 3/8 3/8 250 250 250 250 250 250 230 160 -- 60000 3/8 3/8 250 250 250 225 190 150 110 -- *.Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. —Outside acceptable range Table 2—Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit AC with Puron Advancer"'Refrigerant Maximum Total Equivalent Length": Outdoor unit ABOVE Indoor Liquid Line Liquid Line Vertical Separation ft(m) Size Connection Diam.(in.) 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 w/TXV (7.6) (7.9-15.2) (15.5-22.9) (23.2-30.5) (30.838.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) 1/4 175 250 250 250 250 250 250 250 18000 3/8 5/16 250 250 250 250 250 250 250 250 3/8 250 250 250 250 250 250 250 250 1/4 100 125 175 200 225 250 250 250 24000 3/8 5/16 250 250 250 250 250 250 250 250 3/8 250 250 250 250 250 250 250 250 1/4 30 — — -- -- -- -- -- 30000 3/8 5/16 250 250 250 250 250 250 250 250 3/8 250 250 250 250 250 250 250 250 36000 3/8 5/16 225 250 250 250 250 250 250 250 3/8 250 250 250 250 250 250 250 250 42000 3/8 5/16 175 200 250 250 250 250 250 250 3/8 250 250 250 250 250 250 250 250 48000 3/8 3/8 250 250 250 250 250 250 250 250 60000 3/8 3/8 250 250 250 250 250 250 250 250 *.Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. —Outside acceptable range Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 4 146SAN:Product Data Table 3—Refrigerant Charge Adjustments Liquid Line Size(in.) Puron AdvanceTM'Charge oz/ft(g/m) 3/8 0.60(17.74) (Factory charge for lineset=9 oz/266.16 g) 5/16 0.40(11.83) 1/4 0.27(7.98) Units are factory charged for 15 ft(4.6 m) of 3/8" liquid line. The factory charge for 3/8"lineset 9 oz. (266.16 g). When using other length or diameter liquid lines,charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft X total length)—(factory charge for lineset)]=charge adjustment Example 1:System has 15 ft of lineset*using existing 1/4"liquid line. What charge adjustment is required? Formula:(.27 oz/ft X 15ft)—(9 oz)=(495)oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16"liquid line.What is the charge adjustment? Formula:(.40 oz/ft.X 45ft)—(9 oz.)=9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27C), and outdoor temperature must be 70OF to 100OF(21°C to 380C).If outside these conditions,adjust charge for long linesets by weigh-in method. *When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information. Long Line Applications An application is considered"Long Line"when the total equivalent tubing length exceeds 80 ft or when there is more than 35 ft.vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft.The maximum vertical separation is 200 ft.when outdoor unit is above indoor unit, and 80 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long-Line Application Guideline for required piping and system modifications.Also, refer to table below for acceptable vapor tube diameters to minimize the cooling capacity loss. VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron AdvanceTM refrigerant: Table 4—Vapor Line Sizing and Cooling Capacity Losses—Puron AdvanceTM Refrigerant 1-Stage Air Conditioner Applications Cooling Capacity Loss(%) Total Equivalent Line Length ft.(m) Unit Maximum Acceptable 1-Stage AC with Puron AdvanceTM Nominal Liquid Line Vapor Line Total Equivalent Line Length(ft) Btuh Diameters Diameters Size ( ) (In.OD) (In.OD) Standard Application Long Line Application Requires Accessories 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 1/2 2 5 6 8 10 12 13 15 16 18 3/8 5/8 1 2 3 4 4 5 6 7 7 3/4 1 1 2 2 3 3 3 4 4 5/8 1 3 4 5 6 7 8 9 10 24 3/8 3/4 1 1 2 3 3 4 4 5 5 7/8 0 1 2 2 2 3 3 4 4 5/8 2 4 5 6 8 9 10 11 13 30 3/8 3/4 1 2 2 3 4 4 5 6 6 7/8 1 1 2 2 2 3 3 4 4 5/8 2 4 6 7 9 10 12 13 14 36 3/8 3/4 1 2 3 3 4 5 6 6 7 7/8 1 1 2 2 3 3 4 4 5 3/4 1 3 3 4 5 6 7 8 9 42 3/8 7/8 1 2 2 3 3 4 4 5 6 11/8 0 1 1 1 2 2 2 3 3 3/4 1 3 4 5 6 8 9 10 11 48 3/8 7/8 1 2 2 3 4 4 5 6 6 11/8 0 1 1 1 2 2 2 3 3 3/4 2 4 5 7 8 10 11 12 14 60 3/8 7/8 1 2 3 4 5 6 6 7 8 11/8 0 0 0 1 1 1 2 2 3 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 5 146SAN:Product Data ACCESSORIES KIT NUMBER KIT NAME 18 24 30 36 42 48 60 KSAFT0101AAA FRZTHERM KIT X X X X X X X KAATD0101TDR TIME DELAY KIT(90 second TDR) X X X X X X X KAATD0201TDR TIME DELAY KIT(30 second TDR) X X X X X X X KSALA0301410 LOW AMBIENT COOLING KIT X X X X X X X KSALA1001AAA MOTORMASTER KIT X X X X X X X KSAHS2501AAA HARD START KIT X X X X X X X KSACY0201AAA CYCLE PROTR KIT X X X X X X X KSASF0201AAA SPRT FEET KIT X X X X X X X KAALS0201 LLS* SOL VALVE KIT X X X X X X X KAAWS0101AAA WINTER ST KIT X X X X X X X KAACH1701AAA CRKC HTR KIT X X X X KAACH1601AAA CRKC HTR KIT X X X *.Do not use hard shutoff TXV with liquid solenoid valve X=Accessory Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 6 146SAN:Product Data ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR ACCESSORY LOW-AMBIENT COOLING REQUIRED FOR LONG SEA COAST APPLICATIONS LINE APPLICATIONS APPLICATIONS (Below 55°F/12.8°C) (Within 2 miles/3.22 km) Ball Bearing Fan Motor Standard Standard Standard Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shut-Off TXV Yes Yes Yes Liquid Line Solenoid Valve No No No MotorMaster@ Control or Yes No No Low-Ambient Pressure Switch Support Feet Recommended No Recommended Winter Start Control Yest No No *.For tubing set lengths between 80 and 200 ft.(24 and 61 m)horizontal or 35 ft.(10.7 m)vertical differential(total equivalent length),refer to the Residential Split-System Long Line Application Guideline. t Required if Low Pressure Switch is factory or field installed. Accessory Description and Usage (Listed Alphabetically) 1.Ball-Bearing Fan Motor 6.Low-Ambient Pressure Switch Kit A fan motor with ball bearings which permits speed reduction while A long life pressure switch which is mounted to outdoor unit service maintaining bearing lubrication. valve. It is designed to cycle the outdoor fan motor in order to maintain Usage Guideline: head pressure within normal operating limits(approximately 100 psig to Required on all units when MotorMaster® is used. 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F(-18°C)when properly installed 2.Compressor Start Assist-Capacitor and Relay and also using wind baffles.Instructions provided in accessory kit. Start capacitor and relay gives a"hard" boost to compressor motor at Usage Guideline: each start up. A Low-Ambient Pressure Switch or MotorMasterO Low-Ambient Usage Guideline: Controller must be used when cooling operation is used at outdoor Required for single-phase scroll compressors in the following temperatures below 55°F(12.8°C). applications: 7.MotorMaster@ Low-Ambient Controller Long line A fan-speed control device activated by a temperature sensor, designed Low ambient cooling to control condenser fan motor speed in response to the saturated, Suggested for all compressors in areas with a history of low voltage condensing temperature during operation in cooling mode only. For problems. outdoor temperatures down to—10°F/-23.30C),it maintains condensing 3.Crankcase Heater temperature at 1001F f10°F(37.81C f5.51Q. An electric resistance heater which mounts to the base of the compressor Usage Guideline: to keep the lubricant warm during off cycles. Improves compressor A MotorMaster@ Low Ambient Controller or Low-Ambient lubrication on restart and minimizes the chance of liquid slugging. Pressure Switch must be used when cooling operation is used at Usage Guideline: outdoor temperatures below 55°F(12.8°C). Required in low ambient cooling applications. Suggested for all commercial applications. Required in long line applications. 8.Sound Hood Suggested in all commercial applications. Wraparound sound reducing cover for the compressor. Reduces the 4.Cycle Protector sound level of the compressor. The cycle protector is designed to prevent compressor short cycling. Usage Guideline: This control provides an approximate 5-minute delay after power to the Suggested when unit is installed closer than 15 ft(4.57 m) to quiet compressor has been interrupted for any reason,including power outage, areas,bedrooms,etc. protector control trip,thermostat jiggling,or normal cycling. Suggested when unit is installed between two houses less than 5.Evaporator Freeze Thermostat 10 ft(3 m)apart. An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 7 146SAN:Product Data Accessory Description and Usage (Listed Alphabetically) Continued 9.Support Feet 10.Time-Delay Relay Four or five stick-on plastic feet that raise the unit 4 in. (101.6 mm) An SPST delay relay which briefly continues operation of indoor blower above the mounting pad. This allows sand, dirt, and other debris to be motor to provide additional cooling after the compressor cycles off. flushed from the unit base,minimizing corrosion. NOTE:Most indoor unit controls include this feature.For those that do Usage Guideline: not,use the guideline below. Suggested in the following applications: Usage Guideline: Coastal installations. For improved efficiency ratings for certain combinations of indoor Windy areas or where debris is normally circulating. and outdoor units. Refer to AHRI Directory of Certified Product Rooftop installations. Performance(AHRI Directory). For improved sound ratings. When a Time-Delay Relay(TDR)is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units. 11.Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 8 146SAN:Product Data AHRI RATINGS NOTE:Ratings contained in this document are subject to change at any time. For AHRI ratings certificates,please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here:MyBryantRatings Electrical Data OPER VOLTS" COMPR FAN MAX FUSET or UNIT SIZE V/PH MCA CKT BRK MAX MIN LRA RLA FLA AMPS 18 41.5 8.3 0.5 10.9 15.0 24 60.2 10.3 0.7 13.6 20.0 30 75.6 12.7 0.6 16.5 25.0 36 208/230/1 253 197 75.0 13.5 0.7 17.6 30.0 42 123.0 17.3 1.05 22.7 40.0 48 126.0 22.4 1.05 29.1 50.0 60 157.0 23.7 1.52 31.1 50.0 *.Permissible limits of the voltage range at which the unit will operate satisfactorily t.Time-Delay fuse. FLA-Full Load Amps LRA-Locked Rotor Amps MCA-Minimum Circuit Amps RLA-Rated Load Amps NOTE:Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. A-Weighted Sound Power (dBA) UNIT SIZE STANDARD TYPICAL OCTAVE BAND SPECTRUM (dB,without tone adjustment) RATING(dBA) 125 250 500 1000 2000 4000 8000 18 70 55 58 63 66 62 60 55 24 67 50 59 61 61 60 55 48 30 69 53 58 63 64 62 56 51 36 69 52 57 63 67 60 54 50 42 73 55 64 67 69 65 62 57 48 74 56 66 69 70 66 62 57 60 74 58 64 68 69 65 61 59 NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Charging Subcooling (TXV-Type Expansion Device) UNIT SIZE REQUIRED()BCOOLING Indoor 18 5 24 5 30 6 36 8 TXV 42 6 48 8 60 11 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 9 DIMENSIONS A Tn Pp NG ELECTRICAL A B C D E IFG H I J H OPERATING SHIPPING LENGTIHPIWIDTH SHIPPING Z UNIT SERIES CHARACTERISTICS WEIGHT WEIGHT (Sq) HEIGHT 17 O INCH MM INCH MM INCH MM INCHU24' CH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM Lbs K s Lbs K s INCH MM INCH MM a C 146SP019.OW A Y N N N 31 3116 792.5 32 1/16 815.1 3/4 19.1 ;9/16 1/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 13 330.2 13 314 349.3 17 1/4 438.2 152 68.9 167 75.7 34 1/4 870.0 36 7116 925.1 n 146SA-024.OW A Y N N N 31 3116 792.5 35 1/2 901.4 3/4 19.1 11/16 626.3 9 1/8 231.3 5116 7.9 3 76.2 16 406.4 15 112 393.7 16 1/2 419.1 160 72.6 188 85.3 34 1/4 870.0 3913/16 1011.2 0 w 3 146SA'030'OW A Y N N N 31 3/18 792.5 38 7/8 987.8 3/4 19.1 11/18 826.3 9 1/8 231.3 5/16 7.9 3 78.2 14 1/2 368.3 15 3/4 400.1 17 1/4 438.2 167 75.7 195 88.5 34 1/4 870.0 43 1/4 1099.0 pj d 146WO36.OW A Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 3/4 400.1 16 1/2 419.1 18 114 463.6 176 79.8 191 86.6 34 1/4 870.0 36 7116 925.1 3 �. 146SA'042'0W A Y N N N 31 3116 79Z5 38 7/8 98T8 718 22.2 11/16 626.3 9 1/8 231.3 5/16 T9 3 76.2 16 1/2 419.1 15 3/4 400.1 16 1/4 412.8 219 99.3 246 111.6 34 114 870.0 43 114 1099.0 2) 146SA-048.OW A Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 11/18 626.3 9 1/8 231.3 5/16 7.9 3 76.2 14 1/2 368.3 15 381.0 13 1/2 342.9 202 91.6 217 98.4 34 1/4 870.0 36 7/16 925.1 146SWO60.OW A Y N N N 31 3116 792.5 38 7/8 987.8 7/8 22.2 6 .16 166.1 24 11/16 626.3 9 1/8 231.3 5116 7.9 3 76.2 15 1/2 393.7 14 1/2 368.3 16 1/2 419.1 221 100.2 249 112.9 34 1/4 870.0 43 1/4 1099.0 fD N fO fO Y=YES NOTES: N d A N=NO N 1.CENTER OF GRAVITY S O) TB S O c A so. y AIR DISCHARGE to R AI F D AIR IN AISCHAAGE tv 3 m N a m m FIELD POWER SUPPLY CONN. o -AIR IN N B i/8'1�22.2) HOLE WITH AIR IN 1 1/8"(¢28.61 NNOCN0 T CL FIELD CONTROL SUPPLY COON. CL I E 07/8'(0 22.2) HOLE �lffl�l CD OZ CA LIOUID3 LINE 000NN) K J f S c 3 3/4" 3 112" (96.0) (88.9) H D 3 O L I 0 OCVAPOR LINE CONN. R Y SO.�'I 13/16' 7 �XI_ u6. 1 v2" S0. (12.7) 0 3/8"(09.5) TIEDOWN KNOCKOUTS a (2) PLACES 2 131 6" AIR IN (7 .01 0 UNIT SIZE MINIMUM GROUND MOUNDNG MINIMUM ROOF-TOP MOUNTING » PAD APPLICATION DIMENSIONS PAD APPLICATION DIMENSIONS O 23 1/8 587.3 17 7/8 454.6 a - 25 3/4 654.0 M 7/16 518.5 18,24,30,36,42,48,60 31 3/16 1 792.5 22 15/16 583.2 NOTE:ALL DIMENSIONS IN INCH (MM) U.S.ECCN: Not Subject to Regulation(N.S.R.) p 35 1 889.0 26 3/4 679.7 SD59954146SAN REV.- 3 N CLEARANCESCn A D Z Clearances (various examples) a Q 0 v wall Wall CD Ch 6„ 24„ CD (152.4 mm) Service S \ W fQ w 24" 12" 12" 695(609.6) (304.8) (304.8) (152.4) Service 3 12„ 12„ " (304.8)CD (304.8) 0 Wall C CD 24„ 24" 24„ f (609.6) (609.6) (609.6) 5 Service Service Service O 0 ° 2455 2499 24„ o (609.6) (609.6) (609.6) 0 c m 0 y Note: Numbers in () = mm Allow 48" above unit IMPORTANT:When installing multiple units in an alcove,roof well,or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. DETAILED COOLING CAPACITIES# U) D EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C) Z 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) 0 'o CFM EWB Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Total Sens# kW** Total Sens# kW** Total Sens# kW** Total I Sens# kW** Total Sens# kW** Total Sens# kW**146SAN0180OW Outdoor Section With CVAVA1917XM*Indoor Section l7 01 m 3 72(22.2) 21.12 10.13 1.20 20.29 9.81 1.34 19.46 9.50 1.49 18.57 9.15 1.66 17.55 8.78 1.86 16.44 8.36 2.08 c y 67(19.4) 19.32 12.33 1.21 18.54 12.01 1.35 17.75 11.67 1.50 16.90 11.31 1.67 15.94 10.89 1.87 14.91 10.47 2.09 0 525 63(17.2)tt 17.88 11.86 1.23 17.13 11.52 1.36 16.35 11.15 1.51 15.49 10.74 1.68 14.61 10.33 1.87 13.64 9.91 2.09 62(16.7) 17.63 14.48 1.23 16.88 14.13 1.36 16.13 13.79 1.51 15.32 13.42 1.68 14.45 13.02 1.88 13.52 12.47 2.10 N 57(13.9) 16.95 16.95 1.23 16.36 16.36 1.37 15.70 15.70 1.51 15.03 15.03 1.68 14.34 14.34 1.88 13.56 13.56 2.10 m � 72(22.2) 21.57 10.52 1.23 20.74 10.21 1.37 19.85 9.88 1.53 18.92 9.51 1.70 17.88 9.14 1.90 16.72 8.71 2.12 m N 67(19.4) 19.76 13.00 1.25 18.96 12.66 1.38 18.13 12.32 1.54 17.25 11.95 1.71 16.29 11.53 1.90 15.17 11.06 2.13 m 600 63(17.2)tt 18.30 12.48 1.26 17.51 12.12 1.40 16.70 11.73 1.55 15.86 11.36 1.72 14.91 10.93 1.91 13.90 10.49 2.13 62(16.7) 18.07 15.48 1.26 17.26 15.07 1.40 16.48 14.73 1.55 15.65 14.35 1.72 14.96 14.96 1.91 14.10 14.10 2.13 S 57(13.9) 17.71 17.71 1.26 17.02 17.02 1.40 16.39 16.39 1.55 15.67 15.67 1.72 14.94 14.94 1.91 14.05 14.05 2.13 0 � 72(22.2) 21.93 10.87 1.26 21.06 10.55 1.40 20.17 10.22 1.56 19.17 9.83 1.73 18.13 9.47 1.93 16.94 9.02 2.16 S v 67(19.4) 20.10 13.61 1.28 19.27 13.27 1.42 18.40 12.90 1.57 17.48 12.53 1.75 16.47 12.10 1.94 15.36 11.65 2.16 3 m 675 63(17.2)tt 18.62 13.05 1.29 17.79 12.65 1.43 16.97 12.30 1.58 16.10 11.92 1.75 15.09 11.39 1.95 14.08 11.01 2.17 62(16.7) 18.35 16.32 1.30 17.59 16.04 1.43 16.73 16.73 1.58 16.23 16.23 1.75 15.46 15.46 1.95 14.56 14.56 2.17 v � 57(13.9) 18.33 18.33 1.30 17.63 17.63 1.43 16.97 16.97 1.58 16.17 16.17 1.75 15.38 15.38 1.95 14.45 14.45 2.17 146SAN0240OW Outdoor 3 72(22.2) 26.92 13.27 1.56 25.83 12.82 1.73 24.73 12.38 1.92 23.54 11.90 2.13 22.31 11.35 2.38 20.90 10.80 2.66 67(19.4) 24.52 15.94 1.58 23.56 15.50 1.74 22.55 15.05 1.93 21.39 14.51 2.14 20.28 13.97 2.39 19.03 13.40 2.67 CD 700 63(17.2)tt 22.61 15.33 1.59 21.71 14.90 1.75 20.76 14.41 1.94 19.75 13.91 2.15 18.66 13.38 2.40 17.50 12.81 2.68 0 62(16.7) 22.29 18.55 1.59 21.41 18.10 1.75 20.48 17.63 1.94 19.48 17.12 2.15 18.41 16.58 2.40 17.27 16.02 2.68 0 57(13.9) 21.35 21.35 1.59 20.64 20.64 1.75 19.86 19.86 1.94 19.08 19.08 2.15 18.19 18.19 2.40 17.27 17.27 2.68 m 72(22.2) 27.25 13.50 1.59 26.14 13.05 1.75 25.01 12.59 1.94 23.79 12.11 2.15 22.50 11.55 2.40 21.11 11.03 2.68 a 67(19.4) 24.83 16.31 1.60 23.84 15.88 1.76 22.80 15.40 1.95 21.68 14.88 2.16 20.50 14.37 2.41 19.19 13.75 2.69 H750 63(17.2)tt 22.90 15.69 1.61 21.98 15.24 1.77 20.98 14.73 1.96 19.96 14.24 2.17 18.81 13.69 2.42 17.65 13.13 2.70 3 62(16.7) 22.58 19.07 1.61 21.67 18.62 1.77 20.71 18.15 1.96 19.69 17.63 2.17 18.60 17.08 2.42 17.66 16.60 2.70 N 57(13.9) 1 21.80 21.80 1 1.61 21.06 21.06 1.77 20.26 20.26 1.96 19.45 19.45 2.17 18.52 18.52 2.42 17.58 17.58 2.70 f S 72(22.2) 28.02 14.10 1.65 26.84 13.63 1.82 25.64 13.16 2.01 24.34 12.65 2.22 22.98 12.10 2.47 21.48 11.46 2.75 c 67(19.4) 25.57 17.36 1.67 24.49 16.88 1.83 23.37 16.36 2.02 22.18 15.83 2.23 20.94 15.29 2.48 19.57 14.63 2.76 0 0 900 63(17.2)tt 23.59 16.65 1.68 22.56 16.12 1.84 21.54 15.65 2.03 20.42 15.06 2.24 19.26 14.56 2.49 17.96 13.84 2.77 0 62(16.7) 23.24 20.55 1.68 22.26 20.06 1.84 21.27 19.63 2.03 20.17 19.06 2.24 19.03 19.03 2.49 18.29 18.29 2.77 CD v 57(13.9) 22.88 22.88 1.68 22.10 22.10 1.84 21.26 21.26 2.03 20.34 20.34 2.24 19.38 19.38 2.48 18.22 18.22 2.77 0 a 0 O C O a m 0 3 N DETAILED COOLING CAPACITIES# A U) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C) D Z 75(23.9) 65(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) 0 Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System CFM EWB T Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** v 1 111 Outdoor • Indoor M a 72(22.2) 35.15 17.35 2.07 33.76 16.82 2.27 32.32 16.27 2.50 30.75 15.68 2.76 28.97 15.02 3.06 27.08 14.31 3.39 3 67(19.4) 32.06 21.15 2.07 30.75 20.58 2.28 29.40 20.00 2.51 27.98 19.39 2.77 26.44 18.76 3.07 24.74 18.07 3.40 v ,�. 850 63(17.2)tt 29.69 20.39 2.07 28.43 19.80 2.29 27.17 19.21 2.52 25.86 18.62 2.78 24.41 17.98 3.08 22.88 17.29 3.41 c m 62(16.7) 29.18 24.83 2.08 27.95 24.25 2.29 26.71 23.67 2.52 25.41 23.07 2.79 24.05 22.48 3.09 22.52 22.52 3.42 m 57(13.9) 28.10 28.10 2.08 27.13 27.13 2.29 26.15 26.15 2.53 25.12 25.12 2.79 23.95 23.95 3.08 22.72 22.72 3.41 VI 72(22.2) 36.06 18.22 2.14 34.61 17.68 2.34 33.08 17.11 2.57 31.43 16.50 2.83 29.55 15.80 3.13 27.65 15.13 3.46 CD 67(19.4) 32.92 22.54 2.15 31.55 21.96 2.35 30.12 21.37 2.58 28.60 20.74 2.84 26.97 20.09 3.14 25.17 19.36 3.48 5 1000 63(17.2)tt 30.50 21.68 2.15 29.18 21.08 2.36 27.85 20.49 2.59 26.45 19.86 2.86 24.94 19.18 3.15 23.27 18.46 3.49 CD M. 62(16.7) 29.98 26.80 2.15 28.68 26.21 2.36 27.38 25.66 2.60 26.07 26.07 2.86 25.12 25.12 3.15 23.71 23.71 3.49 29.61 29.61 2.15 28.56 28.56 2.36 27.48 27.48 2.59 26.32 26.32 2.86 25.06 25.06 3.15 23.72 23.72 3.48 72(22.2) 36.63 18.87 2.20 35.12 18.31 2.40 33.53 17.73 2.63 31.83 17.11 2.89 29.88 16.38 3.18 27.93 15.70 3.52 v 67(19.4) 33.44 23.61 2.21 32.03 23.02 2.41 30.55 22.42 2.64 28.98 21.80 2.90 26.85 20.79 3.20 25.42 20.38 3.54 3 1125 63(17.2)tt 31.01 22.67 2.21 29.64 22.07 2.42 28.25 21.46 2.65 26.80 20.83 2.92 25.23 20.16 3.21 23.52 19.42 3.55 SD y 62(16.7) 30.48 28.37 2.21 29.24 27.99 2.42 28.35 28.35 2.65 27.15 27.15 2.91 25.84 25.84 3.21 24.39 24.39 3.54 v 57(13.9) 30.60 30.60 2.21 29.49 29.49 2.42 28.31 28.31 2.65 27.12 27.12 2.91 25.79 25.79 3.21 24.32 24.32 3.55 3 146SAN0360OW Outdoor CVAVA3721XM*Indoor Section 72(22.2) 40.83 19.76 2.33 39.03 19.08 2.60 37.05 18.33 2.87 34.94 17.55 3.17 32.76 16.65 3.52 30.44 15.91 3.96 n 67(19.4) 37.20 24.05 2.34 35.58 23.35 2.62 33.80 22.60 2.89 31.90 21.81 3.19 29.90 20.99 3.54 27.87 20.14 3.97 a CD 1000 63(17.2)tt 34.44 23.19 2.35 32.96 22.51 2.63 31.33 21.76 2.90 29.58 20.98 3.20 27.74 20.17 3.54 25.84 19.33 3.97 62(16.7) 33.81 28.18 2.35 32.35 27.49 2.63 30.75 26.74 2.90 29.04 25.95 3.20 27.28 25.23 3.54 26.28 24.33 3.97 0 57(13.9) 32.70 32.70 2.35 31.54 31.54 2.63 30.24 30.24 2.90 28.86 28.86 3.20 27.38 27.38 3.54 25.82 25.82 3.97 rn 72(22.2) 42.01 20.80 2.42 40.05 20.08 2.68 37.93 19.30 2.96 35.67 18.48 3.26 33.34 17.65 3.61 30.91 16.78 4.05 m CL C 67(19.4) 38.27 25.72 2.44 36.52 25.00 2.71 34.61 24.23 2.98 32.58 23.41 3.28 30.45 22.54 3.64 28.32 21.67 4.07 0. 1200 63(17.2)tt 35.45 24.75 2.45 33.85 24.04 2.72 32.10 23.27 2.99 30.23 22.46 3.29 28.29 21.49 3.64 26.24 20.71 4.07 ID 62(16.7) 34.79 30.53 2.45 33.24 29.84 2.72 31.52 29.08 3.00 29.82 29.82 3.29 28.65 28.65 3.64 26.91 26.91 4.07 v3, 57(13.9) 34.43 34.43 2.45 33.16 33.16 2.72 31.75 31.75 3.00 30.22 30.22 3.29 28.61 28.61 3.64 26.87 26.87 4.07 72(22.2) 42.64 21.48 2.48 40.60 20.74 2.75 38.38 19.94 3.02 36.05 19.11 3.33 33.63 18.25 3.68 31.13 17.37 4.12 S 0 67(19.4) 38.85 26.87 2.51 37.02 26.13 2.78 35.03 25.34 3.05 32.92 24.49 3.35 30.72 23.38 3.71 28.40 22.58 4.14 c_ 3 1350 63(17.2)tt 1 36.00 1 25.81 1 2.52 1 34.33 1 25.09 1 2.79 1 32.50 1 24.30 1 3.07 1 30.55 1 23.46 1 3.37 1 28.53 1 22.60 1 3.72 1 26.35 1 21.56 1 4.14 0 0 62(16.7) 35.34 1 32.21 1 2.52 1 33.75 1 31.59 1 2.80 1 32.68 1 32.68 1 3.07 1 31.05 1 31.05 1 3.36 1 29.30 1 29.30 1 3.71 1 27.50 1 27.50 1 4.14 v 57(13.9) 35.50 1 35.50 1 2.52 1 34.14 1 34.14 1 2.79 1 32.64 1 32.64 1 3.07 1 31.02 1 31.02 1 3.36 1 29.28 1 29.28 1 3.71 1 27.47 1 27.47 1 4.14 3 fl_ 0 O C O a m 0 3 N DETAILED COOLING CAPACITIES# A U) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C) D Z 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) 0 Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System CFM EWB T Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** v a Outdoor '•or Section 72(22.2) 47.99 24.43 2.81 46.07 23.65 3.10 43.99 22.81 3.43 41.69 21.91 3.80 39.21 20.91 4.23 36.53 19.87 4.71 3 67(19.4) 43.60 29.56 2.80 41.87 28.75 3.09 40.00 27.90 3.42 37.98 26.96 3.79 35.75 25.96 4.22 33.31 24.91 4.71 v �. 1200 63(17.2)tt 40.30 28.51 2.80 38.70 27.71 3.09 36.99 26.86 3.41 35.13 25.95 3.79 33.09 24.98 4.22 30.85 23.91 4.71 c m 62(16.7) 39.55 34.47 2.80 37.98 33.67 3.09 36.29 32.82 3.41 34.47 31.91 3.79 32.47 30.95 4.22 30.37 29.97 4.70 m 57(13.9) 38.07 38.07 2.80 36.80 36.80 3.08 35.46 35.46 3.41 34.01 34.01 3.79 32.39 32.39 4.22 30.57 30.57 4.71 N 72(22.2) 49.23 25.48 2.90 47.17 24.65 3.19 44.96 23.78 3.53 42.56 22.83 3.90 39.95 21.82 4.33 37.10 20.73 4.81 CD N 67(19.4) 44.73 31.19 2.90 42.88 30.36 3.19 40.89 29.48 3.52 38.73 28.52 3.89 36.38 27.50 4.32 33.82 26.38 4.81 5 1400 63(17.2)tt 41.35 30.02 2.90 39.65 29.20 3.18 37.82 28.32 3.51 35.84 27.37 3.89 33.69 26.32 4.32 31.32 25.28 4.80 m M. 62(16.7) 40.56 36.75 2.90 38.89 35.92 3.18 37.10 35.04 3.51 35.19 34.18 3.89 33.15 33.32 4.31 31.71 31.71 4.80 57(13.9) 39.76 39.76 2.90 38.42 38.42 3.18 36.98 36.98 3.51 35.39 35.39 3.89 33.64 33.64 4.32 31.66 31.66 4.80 72(22.2) 50.07 26.30 2.99 47.91 25.44 3.28 45.60 24.54 3.61 43.07 23.57 3.99 40.34 22.50 4.42 37.44 21.41 4.90 cs v 67(19.4) 45.49 32.54 2.99 43.55 31.69 3.27 41.47 30.78 3.60 39.23 29.79 3.98 36.78 28.73 4.41 34.06 27.53 4.89 3 1575 63(17.2)tt 4207. 31.28 2.98 40.28 30.43 3.27 38.37 29.54 3.60 36.30 28.56 3.97 34.07 27.54 4.40 31.54 26.32 4.89 SD v 62(16.7) 41.25 38.65 2.98 39.51 37.80 3.27 37.66 36.96 3.60 35.61 35.61 3.97 34.52 34.52 4.40 32.45 32.45 4.89 v 57(13.9) 41.01 41.01 2.98 39.59 39.59 3.27 38.05 38.05 3.60 36.36 36.36 3.97 34.48 34.48 4.40 32.25 32.25 4.88 3 Outdoor 72(22.2) 55.90 27.60 3.41 53.55 26.66 3.77 50.94 25.64 4.19 48.06 ••24.54 4.66 44.88 23.30 5.19 41.20 21.94 5.79 N 67(19.4) 50.93 33.48 3.39 48.83 32.54 3.74 46.50 31.50 4.15 43.91 30.36 4.62 41.01 29.09 5.15 37.70 27.69 5.75 a ID 1400 63(17.2)tt 47.24 32.38 3.38 45.30 31.44 3.72 43.15 30.41 4.13 40.77 29.29 4.59 38.08 28.02 5.12 35.09 26.69 5.73 a 62(16.7) 46.39 39.20 3.37 44.47 38.23 3.72 42.38 37.22 4.12 40.03 36.08 4.59 37.41 34.84 5.12 34.91 34.91 5.72 0 57(13.9) 44.68 44.68 3.37 43.18 43.18 3.71 41.49 41.49 4.12 39.58 39.58 4.58 37.41 37.41 5.12 34.99 34.99 5.73 N 72(22.2) 57.04 28.56 3.51 54.55 27.60 3.87 51.82 26.56 4.29 48.80 25.41 4.76 45.46 24.16 5.30 41.81 22.80 5.90 m CL C 67(19.4) 52.02 35.05 3.49 49.79 34.07 3.85 47.34 33.00 4.26 44.61 31.82 4.72 41.57 30.54 5.26 38.23 29.13 5.86 0. 1600 63(17.2)tt 48.25 33.84 3.48 46.20 32.87 3.82 43.94 31.80 4.23 41.44 30.64 4.70 38.64 29.35 5.23 35.53 27.96 5.83 m 62(16.7) 47.37 41.39 3.47 45.36 40.42 3.82 43.15 39.37 4.22 40.70 38.22 4.69 38.62 38.62 5.23 36.04 36.04 5.84 v3, 57(13.9) 46.37 46.37 3.47 44.75 44.75 3.82 42.91 42.91 4.22 40.88 40.88 4.69 38.59 38.59 5.23 35.99 35.99 5.83 72(22.2) 57.93 29.47 3.61 55.36 28.49 3.97 52.50 27.41 4.39 49.37 26.23 4.87 45.91 24.95 5.40 42.13 23.54 6.00 S 0 67(19.4) 52.86 36.53 3.59 50.54 35.52 3.95 47.97 34.43 4.36 45.13 33.23 4.83 41.98 31.91 5.36 38.53 30.48 5.96 c_ 3 1800 63(17.2)tt 49.05 35.21 3.57 46.91 34.21 3.92 44.55 33.12 4.33 41.94 31.93 4.80 39.09 30.65 5.33 35.83 29.22 5.93 0 0 62(16.7) 1 48.14 1 43.50 1 3.57 1 46.05 1 42.51 1 3.92 1 43.75 1 41.46 1 4.33 1 42.07 1 42.07 1 4.80 1 39.56 1 39.56 1 5.34 36.83 36.83 5.94 y 57(13.9) 47.77 47.77 3.57 46.02 46.02 3.92 44.09 44.09 4.33 41.95 41.95 4.80 39.53 39.53 5.34 36.80 36.80 5.94 3 fl_ 0 O C O a m 0 3 N DETAILED COOLING CAPACITIES# A U) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C) D Z 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) 0 Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capacity M13tuh Total System Capacity MBtuh Total System CFM EWB T Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** Total Sens# kW** v a Outdoor '•or Section 72(22.2) 68.79 34.10 4.23 66.04 33.01 4.68 63.06 31.83 5.19 59.83 30.57 5.77 56.30 29.23 6.43 52.51 27.78 7.17 3 67(19.4) 62.63 41.41 4.19 60.17 40.30 4.63 57.50 39.10 5.13 54.57 37.80 5.71 51.36 36.40 6.37 47.86 34.90 7.11 v �. 1700 63(17.2)lt 58.01 40.00 4.17 55.76 38.91 4.60 53.29 37.71 5.10 50.57 36.42 5.67 47.63 35.08 6.33 44.30 33.50 7.07 c m 62(16.7) 56.95 48.47 4.16 54.73 47.36 4.59 52.30 46.15 5.09 49.61 44.84 5.66 46.66 43.37 6.32 43.49 41.99 7.06 m 57(13.9) 54.89 54.89 4.15 53.14 53.14 4.58 51.20 51.20 5.08 49.05 49.05 5.66 46.51 46.51 6.32 43.96 43.96 7.06 N 72(22.2) 70.44 35.59 4.39 67.53 34.45 4.84 64.38 33.25 5.35 60.97 31.95 5.93 57.28 30.56 6.59 53.27 29.06 7.33 CD N 67(19.4) 64.24 43.82 4.35 61.61 42.65 4.79 58.76 41.41 5.30 55.66 40.07 5.87 52.28 38.64 6.53 48.60 37.08 7.27 5 2000 63(17.2)tt 59.53 42.25 4.32 57.12 41.11 4.76 54.50 39.88 5.26 51.62 38.54 5.83 48.42 37.02 6.48 45.02 35.54 7.22 m M. 62(16.7) 58.43 51.84 4.32 56.06 50.69 4.75 53.47 49.43 5.25 50.63 48.10 5.82 48.53 48.53 6.49 45.69 45.69 7.23 57(13.9) 57.47 57.47 4.31 55.55 55.55 4.75 53.43 53.43 5.25 51.08 51.08 5.83 48.47 48.47 6.49 45.64 45.64 7.23 72(22.2) 71.53 36.73 4.52 68.49 35.57 4.97 65.21 34.33 5.49 61.68 33.00 6.07 57.86 31.57 6.73 53.72 30.04 7.47 v 67(19.4) 65.25 45.67 4.48 62.52 44.50 4.92 59.54 43.22 5.43 56.32 41.87 6.01 52.80 40.32 6.66 49.02 38.83 7.40 3 2250 63(17.2)l l 60.50 43.99 4.45 57.98 42.83 4.89 55.23 41.56 5.39 52.25 40.21 5.96 49.00 38.70 6.61 46.43 37.14 7.35 SD v 62(16.7) 59.38 54.52 4.45 56.90 53.35 4.88 54.22 52.09 5.38 52.46 52.46 5.97 49.73 49.73 6.63 46.80 46.80 7.37 v 57(13.9) 59.18 59.18 4.45 57.14 57.14 4.88 54.89 54.89 5.39 52.41 52.41 5.96 49.70 49.70 6.62 46.72 46.72 7.37 3 t Total and sensible capacities are net capacities.Blower motor heat has been subtracted. 3 t Sensible capacities shown are based on 80°F(27°C)entering air at the indoor coil.For sensible capacities at other than 80°F(27°C),deduct 835 Btuh(245 kW)per 1000 CFM(480 US)of indoor coil air for each degree below 807(27°C),or add 835 Btuh CD (245 kW)per 1000 CFM(480 US)of indoor coil air per degree above 80°F(27°C). #Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2024.If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity may occur. ID ) System kw is total of indoor and outdoor unit kilowatts. F tt At TVA rating indoor condition(75°F edb/63°F ewb).All other indoor air temperatures are at 80°F edb. p; NOTE:When the required data falls between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. 0 EWB-Entering Wet Bulb 0 N d 3 Q Q CD N (G 3 N S O C_ 3 O_ n N v 3 Q S O C O a m 0 3 N 146SAN:Product Data Condenser Only Ratings SST CONDENSER ENTERING AIR TEMPERATURES °F(°C) 55.0(12.8) 65.0(18.3) 75.0(23.9) 1 85.0(29.4) 95.0(35.0) 105.0(40.6) 115.0(46.1) :0O TCG 15.24 14.16 13.22 12.36 11.54 10.71 9.86 30.0 SDT 65.09 74.55 84.14 93.79 103.41 112.99 122.50 KW 0.79 0.90 1.02 1.16 1.30 1.47 1.66 TCG 16.74 15.61 14.63 13.74 12.86 11.98 11.05 35.0 (17) SDT 65.74 75.28 84.85 94.40 104.06 113.60 123.07 KW 0.77 0.89 1.02 1.15 1.30 1.47 1.66 TCG 18.29 17.17 16.15 15.21 14.28 13.34 12.35 40.0 (4.4) SDT 66.55 76.00 85.55 95.10 104.75 114.24 123.70 KW 0.76 0.88 1.01 1.14 1.30 1.47 1.66 TCG 19.96 18.80 17.76 16.78 15.82 14.81 13.75 45.0 (7.2) SDT 67.31 76.78 86.33 95.86 105.34 114.95 124.22 KW 0.74 0.87 1.00 1.13 1.29 1.46 1.65 TCG 21.71 20.54 19.48 18.46 17.45 16.37 15.25 50.0 (10.0) SDT 68.22 77.64 87.12 96.65 106.10 115.72 124.97 KW 0.70 0.85 0.98 1.12 1.28 1.46 1.65 TCG 23.58 22.40 21.30 20.24 19.18 18.05 16.87 55.0 (12.8) SDT 69.00 78.42 87.98 97.51 106.98 116.50 125.72 KW 0.71 0.83 0.97 1.11 1.27 1.45 1.65 -0O TCG 20.00 18.97 17.99 16.99 15.99 14.91 13.80 30.0 SDT 65.31 74.85 84.45 94.06 103.60 113.23 122.83 (-1.1) KW 1.02 1.14 1.29 1.45 1.64 1.86 2.11 TCG 22.12 21.01 19.93 18.85 17.73 16.58 15.42 35.0 SDT 66.11 75.65 85.18 94.74 104.34 113.87 123.24 (1.7) --KW-1 1.01 1.14 1.28 1.45 1.64 1.85 2.10 TCG 24.39 23.20 22.02 20.84 19.63 18.38 17.10 40.0 SDT 66.98 76.46 85.94 95.47 105.03 114.55 123.89 (4.4) KW 1.00 1.13 1.27 1.44 1.63 1.85 2.09 TCG 26.81 25.52 24.25 22.98 21.66 20.30 18.82 45.0 SDT 67.95 77.35 86.78 96.20 105.73 115.26 124.22 (7.2) KW 0.99 1.12 1.27 1.43 1.62 1.84 2.08 TCG 29.40 28.01 26.62 25.24 23.82 22.35 20.77 50.0 SDT 68.92 78.23 87.67 97.10 106.54 116.01 124.83 KW 0.98 1.11 1.26 1.42 1.61 1.83 2.07 TCG 32.14 30.64 29.16 27.64 26.10 24.55 22.86 55.0 SDT 70.02 79.31 88.59 98.02 107.44 116.76 125.64 KW 0.97 1.10 1.24 1.41 1.79 1.83 2.06 00O TCG 25.30 23.61 22.14 20.81 19.59 18.39 17.17 30.0 SDT 67.82 77.25 86.76 96.32 105.85 115.40 124.95 1.27 1.48 1.69 1.92 2.15 2.41 2.70 TCG 27.73 26.00 24.46 23.07 21.73 20.41 19.05 35.0 SDT 68.77 78.15 87.63 97.12 106.67 116.19 125.65 (1.7) KW 1.28 1.48 1.69 1.91 2.15 2.42 2.71 TCG 30.33 28.57 26.97 25.49 24.03 22.59 21.10 40.0 SDT 69.82 79.16 88.59 98.04 107.57 117.02 126.41 (4.4) KW 1.29 1.48 1.69 1.91 2.15 2.42 2.71 TCG 33.17 31.35 29.67 28.08 26.53 24.94 23.31 45.0 SDT 70.82 80.18 89.63 99.06 108.50 117.91 127.15 (7.2) KW 1.30 1.49 1.69 1.91 2.15 2.41 2.71 TCG 36.19 34.31 32.57 30.89 29.21 27.47 25.65 50.0 SDT 71.95 81.32 90.70 100.04 109.46 118.85 128.18 KW 1.32 1.49 1.69 1.90 2.14 2.41 2.71 TCG 39.43 37.51 35.67 33.88 32.07 30.18 28.19 55.0 SDT 73.16 82.46 91.79 101.17 110.51 119.84 129.06 (12.8) KW 1.33 1.50 1.69 1.89 2.13 2.39 2.69 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 16 146SAN:Product Data Condenser Only Ratings (Continued) SST CONDENSER ENTERING AIR TEMPERATURES -F(°C) °F(°C) 55.0(12.8) 65.0(18.3) 75.0(23.9) 1 85.0(29.4) 95.0(35.0) 105.0(40.6) 115.0(46.1) .0O TCG 28.25 27.31 26.09 24.70 23.17 21.55 19.91 30.0 (-1.1) SDT 67.68 77.45 87.08 96.63 106.12 115.54 124.95 KW 1.17 1.57 1.89 2.17 2.44 2.72 3.04 TCG 31.30 30.20 28.83 27.28 25.62 23.84 22.06 35.0 (17) SDT 68.84 78.54 88.12 97.62 107.06 116.43 125.78 KW 1.19 1.57 1.89 2.18 2.45 2.74 3.07 TCG 34.58 33.31 31.78 30.05 28.22 26.31 24.35 40.0 (4.4) SDT 70.08 79.72 89.25 98.68 108.05 117.38 126.66 KW 1.20 1.58 1.90 2.18 2.45 2.75 3.09 TCG 38.11 36.65 34.93 33.03 31.02 28.92 26.79 45.0 (7.2) SDT 71.43 81.00 90.45 99.82 109.14 118.37 127.62 KW 1.22 1.59 1.89 2.18 2.46 2.76 3.11 TCG 41.90 40.22 38.30 36.20 33.98 31.71 29.38 50.0 SDT 72.88 82.37 91.74 101.04 110.26 119.43 128.59 KW 1.23 1.58 1.89 2.17 2.45 2.75 3.11 TCG 45.95 44.03 41.89 39.58 37.14 34.66 32.12 55.0(12.8) SDT 74.47 83.83 93.12 102.33 111.47 120.58 129.63 KW 1.23 1.57 1.87 T-1 5-1 2.43 2.74 3.11 0- 0O 30.0 TCG 34.51 32.93 31.32 29.69 127.98 26.16 24.24 SDT 66.49 76.08 85.66 95.24 104.78 114.30 123.79 (-1.11.1) KW 1.79 2.01 2.26 2.54 2.87 3.25 3.69 TCG 38.13 36.36 34.60 32.82 30.98 29.02 26.94 35.0 SDT 67.53 77.03 86.56 96.09 105.62 115.09 124.53 (1.7) KW 1.79 2.01 2.26 2.54 2.87 3.25 3.69 TCG 41.99 40.07 38.16 36.21 34.21 32.09 29.83 40.0 SDT 68.61 78.07 87.55 97.04 106.52 115.95 125.33 (4.4) -- KVV 1.79 2.01 2.26 2.55 2.88 3.26 3.69 TCG 46.17 44.07 41.98 39.86 37.66 35.36 32.90 45.0 SDT 69.80 79.19 88.62 98.06 107.47 116.86 126.18 (7.2) KW 1.79 2.01 2.26 2.55 2.88 3.26 3.70 TCG 50.68 48.38 46.09 43.78 41.35 38.84 36.17 50.0 SDT 71.09 80.41 89.77 99.17 108.50 117.82 127.10 KW 1.78 2.01 2.27 2.56 2.89 3.27 3.71 TCG 55.51 53.00 50.49 47.94 45.32 41.62 39.66 55.0 SDT 72.47 81.73 91.02 100.26 109.61 118.54 128.07 KW 1.78 2.01 2.27 2.57 2.90 3.27 3.72 :0O TCG 40.62 38.68 36.79 34.81 32.70 30.37 27.82 30.0 SDT 71.79 81.15 90.56 99.93 109.24 118.49 127.62 2.19 2.42 2.70 3.03 3.42 3.89 4.43 TCG 44.68 42.64 40.58 38.46 36.16 33.66 30.91 35.0 SDT 73.27 82.61 91.93 101.25 110.50 119.68 128.76 (1.7) KW 2.20 2.43 2.72 3.05 3.45 3.91 4.45 TCG 49.05 46.87 44.64 42.34 39.86 37.13 34.16 40.0 SDT 74.86 84.14 93.40 102.67 111.87 120.97 129.97 (4.4) KW 219 2.44 2.73 3.08 3.48 3.94 4.47 TCG 53.76 51.40 49.00 46.47 43.76 40.80 37.58 45.0 (7.2) SDT 76.58 85.79 95.03 104.18 113.29 122.31 131.23 KW 2.19 2.45 2.75 3.10 3.51 3.97 4.50 TCG 58.82 56.27 53.62 50.86 47.89 44.68 41.17 50.0 (10.0) SDT 78.47 87.62 96.70 105.80 114.81 123.73 132.56 KW 2.19 2.46 2.77 3.14 3.55 4.02 4.55 TCG 64.19 61.41 58.53 55.50 52.25 48.74 44.94 55.0 (12.8) SDT 80.42 89.48 98.52 107.52 116.44 125.26 133.98 KW 2.18 2.47 2.80 3.17 3.59 4.07 4.60 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 17 146SAN:Product Data Condenser Only Ratings (Continued) SST CONDENSER ENTERING AIR TEMPERATURES 'F(°C) °F(°C) 55.0(12.8) 65.0(18.3) 75.0(23.9) 1 85.0(29.4) 95.0(35.0) 105.0(40.6) 115.0(46.1) 0.00O TCG 48.39 46.46 44.41 42.14 39.61 36.87 33.84 30.0 SDT 71.12 80.58 90.03 99.42 108.76 118.03 127.21 KW 2.67 2.98 3.33 3.75 4.24 4.81 5.47 TCG 53.57 51.42 49.13 46.67 43.97 40.91 37.84 35.0 (17) SDT 72.66 82.04 91.40 100.74 110.03 119.24 128.38 KW 2.67 2.99 3.35 3.78 4.27 4.83 5.49 TCG 59.08 56.66 54.16 51.46 48.53 45.25 42.05 40.0 SDT 74.29 83.58 92.90 102.16 111.41 120.49 129.64 (4.4) KW 2.68 3.01 3.38 3.81 4.30 4.86 5.52 TCG 64.91 62.23 59.44 56.52 53.39 50.05 46.42 45.0 SDT 76.02 85.23 94.44 103.64 112.79 121.87 130.94 (7.2) KW 2.69 3.03 3.41 3.84 4.34 4.92 5.57 TCG 71.04 68.07 65.01 61.78 58.44 54.85 51.01 50.0 SDT 77.84 86.96 96.08 105.18 114.28 123.31 132.27 (10.0) KW 2.71 3.06 3.45 3.89 4.40 4.97 5.63 TCG 77.48 74.17 70.81 67.33 63.68 59.82 55.73 55.0 SDT 79.79 88.86 97.81 106.85 115.85 124.79 133.68 KW 2.75 3.10 3.50 3.95 4.46 5.04 5.70 KW -Outdoor Unit Kilowatts Only. SDT -Saturated Temperature Leaving Compressor(°F) SST -Saturated Temperature Entering Compressor(°F/°C) TCG -Gross Cooling Capacity(1000 Btuh) Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 18 146SAN:Product Data GUIDE SPECIFICATIONS Air-cooled, split-system air conditioner GENERAL 146SAN System Description 1.5 to 5 nominal tons Outdoor-mounted, air-cooled, split-system air conditioner unit suitable Compressor for ground or rooftop installation. Unit consists of a hermetic — Compressor will be hermetically sealed. compressor, an air-cooled coil, propeller-type condenser fan, and a — Compressor will be mounted on rubber vibration isolators. control box.Unit will discharge supply air upward as shown on contract Condenser Coil drawings. Unit will be used in a refrigeration circuit to match up to a — Condenser coil will be air cooled. packaged fan coil or coil unit. — Coil will be constructed of aluminum fins mechanically bonded to Quality Assurance copper or aluminum tubes which are then cleaned,dehydrated,and — Unit will be rated in accordance with the latest edition of AHRI sealed. Standard 210/240. Refrigeration Components — Unit will be certified for capacity and efficiency,and listed in AHRI — Refrigeration circuit components will include liquid-line shutoff directory. valve with sweat connections,vapor-line shutoff valve with sweat — Unit construction will comply with latest edition of ANSI/ connections, system charge of Puron AdvanceTM (R-454B) ASHRAE and with NEC. refrigerant,and compressor oil. — Unit will be constructed in accordance with UL standards and will — Unit will be shipped with filter drier for Puron AdvanceTM carry the UL label of approval.Unit will have c-UL-us approval. (R-454B) refrigerant. — Unit cabinet will be capable of withstanding Federal Test Method Operating Characteristics Standard No. 141 (Method 6061)500-hr salt spray test. — The capacity of the unit will meet or exceed Btuh at a suction — Air-cooled condenser coils will be leak tested at 150 psig and temperature of °F/°C. The power consumption at full load pressure tested at 470 psig. will not exceed kW. — Unit constructed in IS09001 approved facility. — Combination of the unit and the evaporator or fan coil unit will Delivery,Storage,and Handling have a total net cooling capacity of Btuh or greater at — Unit will be shipped as single package only and is stored and conditions of CFM entering air temperature at the evaporator handled per unit manufacturer's recommendations. at °FPC wet bulb and °FPC dry bulb, and air Warranty(for inclusion by specifying engineer) entering the unit at °F/°C. — U.S.and Canada only. — The system will have a SEER2 of Btuh/watt or greater at DOE conditions. PRODUCTS Electrical Requirements Equipment — Nominal unit electrical characteristics will be v, single Factory assembled, single piece, air-cooled air conditioner unit. phase, 60 Hz. The unit will be capable of satisfactory operation Contained within the unit enclosure is all factory wiring, piping, within voltage limits of v to V. controls, compressor, refrigerant charge Puron AdvanceTM (R-454B), — Nominal unit electrical characteristics will be v,three phase, and special features required prior to field start-up. 60 Hz. The unit will be capable of satisfactory operation within Unit Cabinet voltage limits of v to V. Unit cabinet will be constructed of galvanized steel, bonderized, — Unit electrical power will be single point connection. and coated with a powder coat paint. — Control circuit will be 24v. Available with louvered coil guard only. Special Features Fans — Refer to section of this literature identifying accessories and Condenser fan will be direct-drive propeller type, discharging air descriptions for specific features and available enhancements. upward. — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 19 146SAN:Product Data ©2024 Carrier.All rights reserved. Edition Date:08/24 7Catalog No:PDS146SAN-01 Proud Member of the Carrier Family ReplacesNew Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 20 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 - BUILDING PERMIT Er 17916 OXFORD DR Permit#:6681 Parcel#:00893900000500 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:like for like furnace replacement and add ac to hvac system Valuation:16300.00 APPLICANT CONTRACTOR FOWLER AUSTIN R/JANELLE R Bobs Heating BOB'S HEATING 17916 OXFORD DR 14148 NE 190TH STREET 14148 NE 190th St ARLINGTON,WA 98223-4625 WOODINVILLE Woodinville,WA 98072 4258899345 206-378-6723 1JC:BOBSH14A853NQ EXP:09/07/2025 LIC:603 522 028 EXP:07/31/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL . The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 8/21/25 E 08/21/2025 Applicant Signature Date Building Official Date CONDITIONS ' 3"concrete pad with seismic bracing attached is required.Provide electrical disconnect.Lines shall be insulated,and the use of adhesive tapes are prohibited.Adhere to the approved equipment.Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES ' Date Description Fee Amount 08/21/2025 Processing/Technology $25.00 08/21/2025 Inspection $75.00 08/21/2025 A Cond.Unit<100 BTU/h $15.00 08/21/2025 Forced A Heat<100 BTU/h $15.00 08/21/2025 Wti;chanical Base $25.00 08/21/2025 Credit Card Service $4.65 Total Due: $159.65 Total Payment: $159.65 Balance Due: $0.00 - CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 6681 Permit Date: 08/19/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Fowler Applicant Name: Bobs Heating Applicant Address: 14148 NE 190TH STREET Applicant, City, State, Zip: WOODINVILLE Contact: Lucinda Honeycutt Phone: 4258899345 Email: Ihoneycutt@bobsheating.com Scope of Work: like for like furnace replacement and add ac to hvac system Valuation: 16300.00 Square Feet: 1938 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 08/21/2025 Permit Expires: 02/17/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning FOWLERAUSTIN 100 SINGLE 00893900000500 17916 OXFORD DR FAMILY R/JANELLE R RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# BOB'S HEATING Lucinda 206-378-6723 14148 NE 190th CONSTRUCTION Labor&BOBSHI-A853NQ Honeycutt St CONTRACTOR Industries BOB'S HEATING Lucinda 206-378-6723 14148 NE 190th CONSTRUCTION COA 603 522 028 Honeycutt St CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 10/10/2025 ROO.FURNACE 10/17/2025 10/17/2025 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Air Cond.Unit<100 BTU/h Enter#of units $15.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.65 Total $159.65 Attached Letters Date Letter Description 08/21/2025 Building Permit 08/19/2025 Web Form-Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 08/19/2025 Siu Song 240535704 Hannah Hardwick $4.65 08/19/2025 XBP Con£ $155.00 240535704 Outstanding Balance $0.00 Uploaded Files Date File Name 08/21/2025 27933328-20250821 BLD6681 IssuedPermit.pdf 08/19/2025 60aceldbbllaaece33016019aba72423_fowler site nlan.jpg 08/19/2025 14bb6a7809bdl2f4fe39dc87430cOd97 146san equipment specs.pdf 08/19/2025 659999c7a8c35458390663d2329536f2 20815635-residential mechanical.pdf