Loading...
HomeMy WebLinkAbout18329 Hawksview Dr_BLD6685_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 18329 HAWKSVIEW DR Permit#: 6685 Parcel#:00898300001500 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Remove/replace tankless water heater Valuation:6088.00 OWNER APPLICANT CONTRACTOR MASSEY GRANT K Fast Water Heater FAST WATER HEATER 18329 HAWKSVIEW DR 16120 Woodinville-Redmond rd ne suite 15 11715 N CREEK PKWY S,Ste C 106 ARLINGTON,WA 98223-4638 woodinville,wa,98072 BOTHELL,WA 98011 4252960438 425.636.7054 LIC:602 564 544 EXP:05/31/2026 LIC:FASTVAW948BC EXP:01/04/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: r- . PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordnance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordnance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arington must be reported on your sales tax return form and coded City of Arington#3101. 5md &44nt 8/26/2025 08/25/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved appliances.Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/25/2025 Processing/Technology $25.00 08/25/2025 Inspection $75.00 08/25/2025 Wchanical Base $25.00 08/25/2025 Water Heater-LPG $25.00 Total Due: $150.00 Total Payment: $150.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation Addition/Alteration/Repair ❑ Gas Piping Property Address: 18329 Hawksview Drive Project Valuation: 6088 Lot#: Parcel ID No.: Preferred Contact: ❑ Owner 0 Contractor Project Description: Tankless water heater replacement Owner Name: Aime MUyumba Home No.: Email Address: aluboya@gmail.com Cell No.: 425-315-6352 Mailing Address: City: State: Zip:18329 Hawksview Dr Arlington WA .98223 Contractor Name: Fast Water Heater Office No.: 425-298-6968 Email Address: permits its@fastwaterheater.com Cell No.: Mailing Address: 16120 Redmond-Woodinville RD NE#15 City: Woodinville State: WA Zip: 98072 L&I Contractor License Number: FASTWWH948BC Expiration Date: 1/4/2026 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ s/s" 713/4" ❑ 1" ❑ 11/2 ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Air Conditioning Unit> 100 Btu h x $25.00 = Air Conditioning Unit> 500 Btu/hp x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 7 Boiler<100Btu h>3h x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h x $ 15.00 = Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit> 500 Btu/hp x $50.00 = Gas Pipin <_5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 mechanical code,not otherwise specified Package Units<_ 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters<_ 100 Btu/h x $ 15.00 = Unit Heaters>100 Btu/h x $25.00 = Variable Air Volume Boxes (part of Air x $ 10.00 Conditioning System) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired 1 x $25.00 = 25 Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. 9&t6l---� 9&Z"&Af- Jordan Johnson 8/25/2025 S�ignature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Specification Sheet •Certified design according to the latest ANSI Z21.10.3-CSA 4.3 standards for both indoor and outdoor installations(with optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to 24 ft*equivalent length (*see Installation Manual for additional information) •Compatible with 2"PVC vent up to 75 fil and 3"Vent up to 150 ft**(**with no elbows) GasT YPe Recirclation/ Main/Sub •Designed for use in Residential and Commercial applications(see Space Heating below for available models and warranty terms) —Flow Rate/Status .Gas Input Range Combustion/Error Temperature Setting NPE-150SZ 120,000 to 18,000 BTU/h Menu Button Up Button NPE-180A2/S2-150,000 to 10,000 BTU/h NPE-210A2/S2-180,000 to 12,000 BTU/h Back Button Down Button OK Button Power On/Off Button NPE-240A2/S2-199,900 to 13,300 BTU/h •Hot Water Flow Rate Capacity(*based on 35°F temperature rise) NPE-150S2 -6.8 GPM }, NPE-18OA2/S2-8.4 GPM NPE-210A2/S2-10.1 GPM Certified Design Compatible with Multi-Line Control NPE-240A2/S2-11.2 GPM 2"PVC and 1/2"Gas Pipe Panel With Diagnostics • TDR(Turndown Ratio)up to 15:1 • Dual Primary and Secondary Stainless Steel Heat Exchangers for optimum efficiency and durability • Built-in Advanced Multi-Line Control Panel with Setup Wizard allows adjustment of temperature settings and displays of Indoor and Outdoor operating status and error codes } 2"Intake Cap� Venting Options •QOIh11lffOffloW Technology-NPE-A2models come with 2"Couplings built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide 2"Pipe— maximum hot water comfort(NaviCirc Crossover Valve optional) outdoor } -- Vent Cap •INTELLIGENT Preheating-recognizes hot water usage patterns to _ s" intelligently provide hot water to fixtures when needed •Temperature Options-available temperature settings for `O Residential applications range from 97"17 p to 140*F with high- O temperature Commercial mode capable of up to 185°17 e •Ready-Link Cascade Compatible for up to 32 units for increased hot water production Non-Direct Vent(Indoor) Non-Direct Vent(Outdoor) •Common Vent Compatible-allows for cascade systems to use a single exhaust and/or intake pipe for up to 12 units with the use of Direct Vent(Indoor) the Common Vent Backflow Damper Collar Kit(430014367A) •Compatible with NawLnk.Wi-Fi Control(#PECM-AS-001) QEsica •Freeze Protection-maintains normal operation in cold weather *NPE-150S2 conditions when the unit is installed INDOORS and connected to power. Excluded For OUTDOOR installations:the ambient temperature at the installation °Ferlet��® CERTIFIED location must be above 327(O°C)and below 125°F(52°C) Refer to the Installation Manual for additional Freeze Protection guidelines •Uniform Energy Factor(listed models for use with Natural Gas and Propane) NPE-15OS2 -0.93 UEF NPE-180A2/210A2/240A2-0.95 UEF NPE-18OS2/21OS2/24OS2 -0.96 UEF Job Name: •Compatible for use with Natural Gas(NG)and Propane(LP)Gas*** (***requires installation of included Gas Conversion Kit by a qualified gas servicer) Location: •Approved for installations on Manufactured Homes Engineer: •Certified by CSA Group,NSF 5 and 372 Low Lead,AHRI Certified,SCAQMD Wholesaler: (Rule 1146.2 Type 1-Complies with 14 ng/J or 20 ppm NOx @ 3%02) Contractor: •Limited Warranty-15-Year Heat Exchanger and 5-Year Parts(Residential)**** Model No.: 8-Year Heat Exchanger and 5-Year Parts(Commercial)**** Submitted to: (****full details of warranty terms available in the Navien manuals or website) •Optional Accessories are available(see below) 1 00 t Remote Controller Plumb Easy Valve Set(3/4") Condensate Neutralizer Ready-Link 3"Vent Termination (30009323A-Lead Free) (GXXX001322-Single Unit) Communication Cable NPE-(30025 0 Vent Kit External Pump Wire Caps and Wall Flanges (300227176) (30025812A-for Pipe Cover) (GXXX001324-Up to6 Units) (GXXX000546) (30025801 A) (GXXX001319) (GXXX38736) (GXXX001325-Up to 16 Units) 1-NPE2-SS-001-1.1 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Specification Sheet Front View Item NPE-150S2* NPE-180A2 NPE-18052 PPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 Heat Capacity Natural Gas, 18,000-120,000(Input) Propane Gas BiU/H 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H Uniform UEF(forNG&LP) 0.93 0.95 0.96 0.95 0.96 0.95 0.96 Energy Factor E 35°F(19°C) 6.8 GPM E $ Temp Rise (25.8 Urn) 8.4 GPM(32 Vm) 10.1 GPM(38 Um) 11.2 GPM(42 Urn) E Flow Rate 45 T(25'Q 5.3 GPM 6.5 GPM(25 Um) 7.8 GPM(30 Um) 8.7 GPM(33 Um) (DHW) Temp Rise (20 Um) 67T(36'Q 3.4GPM 4.3GPM 4AGPM 5.1GPM 5.3GPM 5.6GPM 5.8GPM Temp Rise (13 Um) (16 Um) (17 Um) (19 Um) (20 Um) (21 Um) (22 Um) ❑ Dimensions 17.3 in(W)x 27.4 in(H)x 13.2 in(D) Weight 62lbs 73lbs 68lbs 77lbs 73lbs 77lbs 73lbs =a (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) Installation Type Indoor or Outdoor Wall-Hung Overhead view Venting Type Forced Draft Direct Vent oIgnition Electronic Ignition Ism(Mmm) 143(u non) Water Pressure 15-150PSI e Natural Gas Supply Pressure 3.5 in WC-10.5 in WC E r (from source) Propane Gas Supply Pressure 8 in WC-13in WC Z"(170�rN4 (from source) 0 Natural Gas Manifold Pressure -0.04 in WC- (min-max) -0.40inWC -0.03inWC--0.55inWC -0.03 in WC--0.76 in WC -0.03 in WC--0.96 in WC Propane Gas Manifold Pressure -0.03 in WC- -0.02 in WC--0.55 in WC -0.02 in WC--0.76 in WC -0.02 in WC--0.96 in WC (min-max) -0.40 in WC Supply connections Minimum Flow Rate 0.5 GPM(1.9 Um),<0.01 GPM(0.04 Um)option for"A2"models** Description Diameter 40 41 40 40 Cold Water Inlet a/,in NPT A Air Intake 2 in Connection Hot Water a/,in NPT B Exhaust Gas Vent tin Sizes Outlet C Hotwateroutlet 3/,in �p Gas Inlet a/,in NPT D Gaslnlet 3/,in asp d ® Main Supply 120V AC,60Hz E ReclrculationInlet °/.in ® O _ Power Supply Maximum IF Condensate outlet v,in ° m Power 200 W(max 2 A),350 W(max 4 A)with external pump connected " •v' s Consumption G Cold Water Inlet '/sin mmml]omm ml a,i a]mM �Va Cold Rolled Carbon Steel Materials Primary Heat Exchanger:Stainless Steel Exchangers Secondary Heat Exchanger:Stainless Steel NPE-180A2121OA2I240A2 Exhaust 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel 2 in or 3 in Special Gas Vent Type BH(Class II,A/B/Q Supply Connections Venting 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel Description Diameter Intake 2 in or 3 in Special Gas Vent Type BH(Class II,A/B/C) A Air Intake tin _ Vent Clearances 0 in to combustibles B Exhaust Gas Vent tin -� High Elevation 10,100 feetfor both NG or LP gas.Please referto Installation Manual foradditional details and instructions. C Hot Water Outlet '/,in7 E4_ 7� D Gaslnlet ,/,in _ ® FlameRod,APS,IgnitionOperationDetector,WaterTemperatureHighLimitSwitch,ExhaustTemperatureHighLimitSensor, Safety Devices E Condensate Outlet '/,in 9 9Power Sur a Fuse,Burner Hi h Limit Fuse,Vent Installation Detector(VID) = m F Cold Water Inlet ;/,in s *NPE-150S2 model not certified by EnergyStar ��lamM **Available for"A2"models configured in an optional ComfortFlow recirculation mode.Energy consumption will increase when the system is configured for recirculation. n3inlwamM NPE-150S2I 180S21210S21240S2 Gas-fired,tankless,condensing,wall-mounted water heater(s)shall be direct vent NPE-2 Series models as manufactured by Navien,Inc.and are certified by CSA Group to the latest edition of ANSI Standard Z21.10.3-CSA 4.3.Water heater(s)shall have a 15(5)year limited Heat Exchanger warranty and 5(3)year limited Parts warranty(8(5)year Heat Exchanger and 5(3)year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn naturalgas and can be for use with propane when a Gas Conversion Kit is installed. (qty). NPE water heater(s)shall have a nominal flow rate capacity of GPM/GPH at °F rise with rated input of BTU/hr.Water heater(s)shall be vented with 2"Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at distance not to exceed 75'(or equivalent)with each elbow equal to 8'of pipe length or3"Schedule 40/80 PVC/ CPVC,approved polypropylene and stainless steel vent pipe at a distance of 150'(or equivalent)with each elbow equal to 5'of pipe length.Water heater(s)is rated for 150 PSI working water pressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WC for natural gas and 8.0"to 13.0"WC for propane.Unit(s)shall have a steel case,dual stainless steel heat exchangers,eco premixed burner,negative pressure gas valve,dual venturi,3/4"inletgas connection,3/4"brass inlet/outlet water connections,water holding capacity of 0.6gallons for the NPE-150S2,1.0 gallonfor the NPE-180A2 model(0.7gallonsforNPE-18OS2 model),1.2 gallons for the NPE-21OA2/NPE-24OA2 models(0.7 and 0.9 gallonsforNPE-21OS2 and NPE-240S2 models respectively),and a condensate collector.The NPE-180A2 model weighs 73lbs(NPE-180S2 weighs 68lbs),and the NPE-21OA2/NPE-24OA2 models weigh 77lbs(NPE-21OS2 and NPE-240S2 weigh 731bs)and the NPE-150S2 weigh 621bs.Unit(s)shall include features such as an adjustmentfor installations at high elevation,temperature lockout,and temperature options from 97-120°F in 1°Fintervals and 120-140°F in 1°Fintervals.The unit(s)shall include additional temperature options of 140-185°F in 1°F intervals,for high temperature commercial applications.All NPE'A2"models shall include an internal circulation pump and 0.5-gallon buffer tank.The water heater(s)shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors,sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal combustion efficiency.Unit(s)shall include safety features such as flame sensorsystem,high limit sensors,overheat prevention device,freeze protection mode,and fan motor rotation detector.Multi- system(cascade)applications that require 2 to 32 units shall be installed by connecting the units using cable only connections(Ready Link).The water heater(s)exceeds the energy efficiency requirements ofASHRAE 90.1-2010 and is listed by SCAQMD Rule 1146.2(Type 1)as compliant with Rule 1146.2(Type 1)for Ultra Low NOx requirements of 14 ng/)or 20 ppm @ 3%02. r Navien reserves the right to change specifications at any time without prior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.NavienInc.com 1-NPE2-SS-001-1.1 Permit#: 6685 Permit Date: 08/25/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Muyumba Applicant Name: Fast Water Heater Applicant Address: 16120 Woodinville-Redmond rd ne suite 15 Applicant, City, State, Zip: Woodinville, wa, 98072 Contact: Jordan Johnson Phone: 4252960438 Email: permits@fastwaterheater.com Scope of Work: Remove/replace tankless water heater Valuation: 6088.00 Square Feet: 2383 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 08/26/2025 Permit Expires: 02/25/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00898300001500 18329 HAWKSVIEW DR MASSEY GRANT K FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# FAST WATER 11715 N CREEK PLUMBING HEATER 425.636.7054 PKWY S,Ste CONTRACTOR COA 602 564 544 C106 FAST WATER It715 N CREEK PLUMBING LABOR& HEATER 425.636.7054 PKWY S,Ste CONTRACTOR INDUSTRIES FASTWWH948BC C106 Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 10/10/2025 C00. 10/13/2025 10/13/2025 BUILDING Approved CONSULTATION Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Mechanical Base Permit Fee $25.00 Water Heater-LPG Gas Fired $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 08/25/2025 Building Permit 08/25/2025 Web Form-Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 08/25/2025 Anthony Danese 241194284 Hannah Hardwick $4.50 08/25/2025 XBP Con£ $150.00 241194284 Outstanding Balance $0.00 Uploaded Files Date File Name 08/26/2025 27994372-2025 BLD6685 IssuedPermit.pdf 08/25/2025 b27382e7226712ecccfb3cbadebble06 3105408 app.pdf 08/25/2025 7a30f6129445146b43ec3fOf2194d0e0 3105408 specs.pdf