Loading...
HomeMy WebLinkAbout17613 Muirfield Ct_BLD6823_2026 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater •Certified design according to ANSI Z21.10.3-CSA 4.3 latest standards for both indoor or outdoor installations(with optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to a length of 24 ft* (*see Installation Manual for additional information) •Compatible with 2"PVC vent up to 75 ft**and 150 ft** Gas Type using 3"PVC vent(**with no elbows) Recirclation/ Main/Sub Space Heating IM —Flow Rate/Status •Designed for use in Residential and CommercialI?O*F-Temperature Setting applications(see below for available models and warranty terms) Combustion/Error •Gas Input Ranges NPE-180A2/S2-150,000 to 10,000 BTU/h Menu Button Up Button NPE-210A2/S2 -180,000 to 12,000 BTU/h Back Button Down Button NPE-240A2/S2 -199,900 to 13,300 BTU/h OK Button Power On/Off Button NPE-150S2 120,000 to 18,000 BTU/h •Hot Water Flow Rate Capacity(*based on 350F temperature rise) NPE-18OA2/S2 8.4 GPM NPE-21OA2/S2 10.1 GPM Sleek Design NPE-240A2/S2 11.2 GPM NPE-150 S2 6.8 GPM Compatible with Built-In Control Panel • TDR(Turn Down Ratio)up to15:1 2"PVC and 112"Gas Pipe •Dual Primary and Secondary Stainless Steel Heat with Diagnostics Exchangers for optimum efficiency and durability •Buit-In-Advanced Multi-Lines Control Panel with setup wizard allows adjustment of temperature settings and displays of Indoor and Outdoor operating status and error codes } 2"Intake Cap� Venting Options •QOmOo wfflOW-Technology-"A2"models come included with 2"Coupling La built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide 2"Pipe Out comfort outdoor Ven[Cap— •INTELLIGENT Preheating-recognizes hot water usage patterns to intelligently provide hot water when needed(optional for"s"models) O •Temperature Options -available temperature settings for Residential applications range from97'F up to 140*F with high O temperature Commercial mode capable of up to 185'F •Ready-Link Cascade Compatible for up to 32 units for increased Non-Direct Vent(Indoor) Non-Direct Vent(Outdoor) hot water production Common Vent Compatible-allows for cascade systems to use a Direct Vert(Indoor) single exhaust and/or intake pipe for up to 12 units with the use of the Common Vent Backflow Damper Collar Kit(n30014367A) _ oESlea •Compatible with Navffin(.Wi-Fi Control(nPBCM-AS-001) •Freeze Protection-maintains normal operation during freezing eFRrIFt�°® CERTIFIED ambient temperatures down to-5'F(standard on all models) •Uniform Energy Factor Ratings for NG and LP units NPE-18OA2/21OA2/24OA2-0.95 UEF c NPE-180S2/21OS2/24OS2 -0.96 UEF NPE-150S2 -0.93 UEF *** •Compatible with Natural Gas(NG)and Propane(LPG) Job Name: (***requires installation of included Field Conversion Kit by a qualified gas servicer) -- •Approved for Installations on Manufactured Homes Location: •Optional NaviCirc Crossover Valve Compatible Engineer: •Certified by CSA,NSF 5,AHRI,AB1953 CA Low Lead,SCAQMD Wholesaler: (Rule 1146.2 Type 1-Complies with 14 ng/J or 20 ppm NOx @ 3%02) Contractor: •15-Year Heat Exchanger and 5-Year Parts Warranty(Residential)**** Model No.: 8-Year Heat Exchanger and 5-Year Parts Warranty(Commercial)**** (****see Navien Limited Warranty) Submitted to: •Optional accessories are available(see below) ®o 0 Qo CondensateNeutralaer Remote Controller Plumb -Lad (3/4") Ready-Link 3"VeitTermnatan (GXXX001 322-Single Unit) OutdoorVent lGt External Pump Wire (30009323A-Lead Free) (GXXX001 324-Up to Units) CommumcationCable (30025801A) (GXXX001319) Caps and Wall Flanges (30022717B) (30025812A-for Pipe Cover) (GXXX001 325-Up to 16 Units) (GXXX000546) (GXXX3873B) 1-NPE2-SS-001-1.0 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Specification Sheet Item NPE-150S2 NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 Heat Capacity Natural Gas, 18,000-120,000 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H (Input) Propane Gas BTU/H Uniform UEF(for NG&LP) 0.93 0.95 0.95 0.95 0.96 0.95 0.96 Energy Factor 35°F(19°C) 6.8 GPM 8.4 GPM(32 Um) 10.1 GPM(38 Um) 11.2 GPM(42 Um) a Temp Rise (25.8 Um) Flow Rate 45 T(25°C) 5.3 GPM 6.5 GPM(25 Um) 7.8 GPM(30 Um) 8.7 GPM(33 Um) (DHW) Temp Rise (20 Um) 67T(36°Q 3AGPM 4.3GPM 4.4GPM 5.1GPM 5.3GPM 5.6GPM 5.8GPM Temp Rise (13 Um) (16 Um) (17 Um) (19 Um) (20 Um) (21 Um) (22 Um) Dimensions 17.3 in(W)x 27A in(H)x 13.2 in(D) a Weight 62lbs 73lbs 168lbs 77lbs 73lbs 77lbs 73lbs (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) Installation Type Indoor or Outdoor Wall-Hung Overhead View Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Ise°u­ 43­.) Water Pressure 15-150 PSI Natural Gas Supply Pressure �IJI (from source) 3.5 in WC-10.5 in WC m:� eamimmml T Propane Gas Supply Pressure 8 in WC-13in WC (from source) Natural Gas Manifold Pressure -0.04inWC (min-max) -0.40inWC -003inWC--0.55inWC -0.03 in WC--0.76 in WC -0.03 in WC--0.96 in WC Propane Gas Manifold Pressure -0.03inWC- _0.02 in WC--0.55 in WC -0.02 in WC--0.76 in WC -0.02inWC--0.96inWC NPE-180A2/210A2/240A2 (min-max) -0.40in WC SupplyConnections SupplyConnections Minimum Flow Rate 0.5 GPM(1.9 Um),<0.01 GPM(0.04 Um)option for"A2"models* Description diameter e © 40 Cold Water Inlet 3/4 in NPT A Airintake zin Connection Hot Water 3/,inNPT Sizes Outlet B Exhaust Gas Vent tin Gas Inlet 3/,inNPT C Hot Water Outlet V.In Main Supply 120VAC,60Hz D Gas Inlet '/.In Maximum E Recirculationlnlet =/.m " �.m O Power Supply v, -_ = Power 200 W(max 2 A),350 W(max 4 A)with external pump connected F Condensate Outlet in Consumption G Cold Water Inlet in Casing Cold Rolled Carbon Steel 173°hw ni Materials Heat Primary Heat Exchanger:Stainless Steel NPE-1509E/18GS2/210S2/240S2 Exchangers Secondary Heat Exchanger:Stainless Steel Exhaust 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel SupplyConnections SupplyConnations 2 in or 3 in Special GasVentType BH(Class II,A/B/C) Ill Descripion diameter a Venting Intake 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel 2 in or 3 in Special GasVentType BH(Class II,A/B/C) A Air Intake tin �T Vent Clearances 0 in to combustibles B Exhaust Gas Vent tin C H°twateroutlet V/in - outer ® High Elevation 10,100feetforbothNGorLPgas.PleaserefertoInstallationManualforadditionaldetailsandinstructions. D Gas Inlet %in v,in 0 Flame Rod,APS,Ignition Operation Detector,WaterTemperature High Limit Switch,Exhaust Temperature High Limit Sensor,E Condensate Outlet Power Surge Fuse,Burner High Limit Fuse,Vent Installation Detector(VID) F Cold Waterinlet V.in - S -Available for"A2"models configured in an optional ComfonFlow recirculation mode.Energy consumption will increase when the system is configured for recirculation. Gas-fired,tankless,condensing,wall-mounted water heater(s)shall be direct vent NPE-2 Series models as manufactured by Navien,Inc.and are certified by CSA International to the latest edition ofANSI standard Z21.10.3/CSA 4.3.Water heater(s)shall have a 15(5)year limited Heat Exchanger warranty and 5(3)year limited Parts warranty(8(5)year Heat Exchanger and 5(3)year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is installed. (qty)NPE water heater(s)shall have a nominal flow rate capacity of GPM/GPH at-'F rise with rated input of BTU/hr.Water heater(s)shall be vented with 2"Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at a distance not to exceed 75'(or equivalent)with each elbow equal to 8'of pipe length or 3" Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at a distance of 150'(or equivalent)with each elbow equal to 5'of pipe length.Water heater(s)is rated for 150 PSI working water pressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WC for natural gas and 8.0"to 13.0"WCfor propane.Unit(s)shall have a steel case,dual stainless steel heat exchangers,eco premixed burner,negative pressure gas valve,dual venturi,3/4"inlet gas connection,3/4"brass inlet/outlet water connections,water holding capacity of 0.6 gallon for the NPE-150S2,1.0 gallon for the NPE-180A2 model(0.7gallonsfor NPE-180S2 model),1.2 gallons for the NPE-21OA2/NPE-24OA2 models(0.7 and 0.9 gallons for NPE-21OS2 and NPE-240S2 models respectively),and a condensate collector.The NPE-180A2 model weighs 73 lbs(NPE-I80S2 weighs 68lbs),and the NPE-21OA2/NPE-24OA2 models weigh 771bs(NPE- 210S2 and NPE-240S2 weigh 731bs)and The NPE-150S2 weigh 62lbs.Unit(s)shall include features such as an adjustment for installations at high elevation,temperature lockout,and temperature options from 97-120°Fin 1°F intervals and 120-140°F in 1°F intervals.The unit(s)shall include additional temperature options of 140-I85°F in 1°Fintervals,for high temperature commercial applications.All NPE"A2"models shall include an internal circulation pump and 0.5-gallon buffer tank.The water heater(s)shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors,sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal combustion efficiency.Unit(s)shall include safety featuressuch as flame sensor system,high limitsensors,overheat prevention device,freeze protection mode,and fan motor rotation detector.Multi-system(cascade)applications that require 2 to 32 units shall be installed by connecting the units using cable only connections(Ready Link).The water heater(s)exceeds the energy efficiency requirements of ASHRAE 90.1-2010 and is listed by SCAQMD rule 1146.2(Type 1)for Low NOx that complies with 14 ng/)or 20 ppm NOx requirements @ 3%02. *Navien reserves the right to change specifications at any time without prior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.NavienInc.com 1-NPE2-SS-001-1.0 RESIDENTIAL PLUMBING APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new,repaired,altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. Type of Permit: ❑ New Installation ❑ Addition 0 Alteration ❑ Repair Property Address: 17613 M U I RF I E LD CT Project Valuation: 9014 Lot#: Parcel ID No.: 00809200006700 Preferred Contact: 71 Owner ❑ Contractor Project Description:TANK TO TANKLESS INSTALL (NG) Owner Name: BRIAN AND LISA BROGDEN Home No.: 3604350868 Email Address: BROGDINO@AOL.COM Cell No.: 4253277127 Mailing Address: 17613 MUIRFIELD CT City: ARLINGTON State: WA Zip: 98223 Contractor Name: CM HEATING Office No.: 4252590550 Email Address: PERMITS@CMHEATING.COM Cell No.: Mailing Address: 1500 INDUSTRY ST#200 City: EVERETT State: WA Zip: 98203 L&I Contractor License Number: CMHEAHL751 LW Expiration Date: 06/30/26 • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Proposed Interior Water Piping Size: ❑ 1/2" ❑ S/a" ❑ 3/4' ❑ 1" Proposed Interior Piping Material: ❑ CPVC ❑ Brass ❑ Copper ❑ PEX-AL-PEX ❑ PEX ❑ Galvanized Steel ❑ Other Proposed Exterior Water Piping Size: ❑ 1/2" ❑ S/a" ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" Proposed Exterior Piping Material: ❑ PVC ❑ PE ❑ Copper ❑ PEX-AL-PEX ❑ PEX-AL-PE ❑ PEX ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ Schedule 40 ABS DWV ❑ Copper ❑ Galvanized Steel ❑ Cast Iron Material: ❑ Schedule 40 PVC DWV ❑ Brass ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ 1/2" ❑ s/e" ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" ❑ 3" 04" Piping Size: PLUMBING PERMIT FEES (per fixture) Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration/repair piping x $15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee 1 x $25.00 = $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste x $25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 = REV03.2022 Pagel of 2 PLUMBING PERMIT FEES (per fixture) Drinking Fountain x $15.00 = Floor Drains x $15.00 = Grease Interceptor x $75.00 = Grease Trap x $25.00 = Hose Bibb x $15.00 = Icemaker Refri erator x $15.00 = Irrigation-per meter x $25.00 = Kitchen Sink&Disposal x $15.00 = Laundry Tray x $15.00 = Lavatory x $15.00 = Med Gas Pi in <-5 inlets outlets x $60.00 = Med Gas Piping>5 inlets/outlets(plus:5 5 x $5.00 = inlets outlets Miscellaneous-regulated by plumbing code,not x $15.00 = otherwise specified Pretreatment Interceptor x $15.00 = Re-inspection Fee x $75.00 = Roof Drains x $15.00 = Shower(only) x $15.00 = Sink bar,service,etc. x $15.00 = Toilets x $15.00 = Urinal x $15.00 = Vacuum Breakers x $25.00 = Water Heater x $25.00 = MODEL NO.: Water Heater-Tankless 1 x $25.00 =25 MODEL NO.: NPE-S2 Permit Fee 50.00 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 150.00 I hereby certify that 1 am the❑ Owner, ❑Applicant, El Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. BRITTNY MILLER 2/19/26 Signature Print Name Date SAVE PRINT REV03.2022 Page 2 of 2 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17613 MUIRFIELD CRT Permit#: 6823 Parcel#:00809200006700 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:INSTALL TANKLESS Valuation:9014.07 OWNER APPLICANT CONTRACTOR BROGDEN BRIAN C&LISA D BRITTNY MILLER CM HEATING INC 17613 MUIRFIELD CT 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 ARLINGTON,WA 98223 EVERETT,WA 98203 EVERETT,WA 98203 425 259 0550 425-259-0550 I.IC: Dom:00/30/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL PLUMBING CODE YEAR: 2021 STORIES: 0 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC1 10/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 02/20/2026 Applicant Signature Date Building Official Date CONDITIONS Inspection is required. Call for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 02/20/2026 Processing/Technology $25.00 02/20/2026 Inspection $75.00 02/20/2026 Pipe Alteration or Repair $15.00 02/20/2026 Plumbing Base $25.00 02/20/2026 Water Heater(Tankless) $25.00 02/20/2026 Credit Card Service $4.95 Total Due: $169.95 Total Payment: $169.95 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 6823 Permit Date: 02/19/26 Permit Type: RESIDENTIAL PLUMBING Project Name: BROGDAN PLUMBING Applicant Name: BRITTNY MILLER Applicant Address: 1500 INDUSTRY ST#200 Applicant, City, State, Zip: EVERETT,WA 98203 Contact: CM HEATING Phone: 425 259 0550 Email: PERMITS@CMHEATING.COM Scope of Work: INSTALL TANKLESS Valuation: 9014.07 Square Feet: 0 Number of Stories: 0 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 02/20/2026 Permit Expires: 08/19/2026 Form Permit Type: RESIDENTIAL PLUMBING Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning BROGDEN BRIAN 100 SINGLE 00809200006700 17613 MUIRFIELD CRT FAMILY C&LISA D RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION COA ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R14.PLUMBING After 1:00 pm.Please call 03/18/2026 FINAL Brian when you are on your 03/19/2026 03/19/2026 BUILDING Approved way.360-435-0868 Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Pipe Alteration or Repair $15.00 Plumbing Base Permit Fee $25.00 Water Heater(Tankless) $25.00 Credit Card Service $4.95 Total $169.95 Attached Letters Date Letter Description 02/20/2026 Building Permit 02/19/2026 Web Form-Residential Plumbing Application Payments Date Paid By Description Payment Type Accepted By Amount 02/19/2026 Kim Yeung cc LaNay Hendrick $4.95 02/19/2026 XBP Con£ $165.00 305588138 Outstanding Balance $0.00 Uploaded Files Date File Name 02/19/2026 fcef892882bdc574fb6b8b049024be57 BROGDAN SPEC.pdf 02/19/2026 2016948blbdcdfbd4e2abe8042fcbe8f BROGDAN MECH APP.pdf 02/19/2026 2016948blbdcdfbd4e2abe8042fcbe8f BROGDAN MECH APP.pdf