Loading...
HomeMy WebLinkAbout18707 29th Ave Ne_BLD5498_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD5498 Residential Plumbing 18707 29th Ave Ne EXPIRED February 2024 ✔ ✔ ✔ 18707 29TH AVE NE, UNIT A 3103 31052000104000 REMOVE/REP LAC E GAS WATER HEATER GP S RENTING 4252178661 permits@ fastwaterheater.com ✔ ✔ 18707 29TH AVE NE, UNIT A Arlington WA 98223 FAST WATER HEATER 425-636-7054 permits@ fastwaterheater.com 11715 N C reek P KWY S #C 106 Bothell WA 98011 FASTWWH948BC 1/4/24 1 08/20 FORM NO. THD-PE06 N Rev. 6 PERFORMANCE 20 to 50-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models See specifications chart on back. PERFORMANCE® electric water heaters feature dual copper heating elements and a six-year warranty Efficiency .90 - .93 UEF Isolated tank design reduces conductive heat loss Dual 3800W or 4500W copper heating elements depending on unit Performance FHR: 33 - 61 gallons, based on gallon capacity Recovery: Up to 21 GPH at a 90° F rise, depending on model** Longer Life Premium grade anode rod provides long-lasting tank protection Features Electric junction box located above heating elements for easy installation Over-temperature protector cuts off power in excess temperature situations Plus… Temperature and pressure relief valve included Models are compliant to HUD Standards for manufactured housing and modular construction Low lead compliant Warranty 6-Year limited warranty for tank and parts, 1-year full in-home labor warranty* *See written warranty for complete details Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. ® Fuel Type Description NominalGallonCapacity RatedGallonCapacity Model Number Recovery in G.P.H.90° F Rise First HourRatingG.P.H. TankHeightA Height to Water Conn.B Diameter C Ship Weight(LBS.) UniformEnergy Factor(UEF) Electric Tall 50 45 XE50T06ST45U1 21 61 58-7/8 61-5/8 20-1/4 121 0.93 Electric Medium 50 45 XE50M06ST45U1 21 61 48 50-1/2 23 132 0.93 Electric Short 47 43 XE47S06ST45U1 21 54 32 34 26-1/4 148 0.93 Electric Tall 40 36 XE40T06ST45U1 21 54 60-3/4 63-5/8 19-1/4 109 0.93 Electric Medium 40 36 XE40M06ST45U1 21 53 48-1/4 50-1/2 20-1/4 106 0.93 Electric Medium 40 36 XE40M06ST38U1 17 52 48-1/4 50-1/2 20-1/4 106 0.93 Electric Short 38 35 XE38S06ST45U1*21 51 31-1/2 34 23 108 0.92 Electric Short 38 35 XE38S06ST38U1*17 49 31-1/2 34 23 108 0.91 Electric Short 36 33 XE36S06ST45U0 21 46 31-1/2 33 24-1/4 118 0.92 Electric Short 36 33 XE36S06ST38U0 17 34 31-1/2 33 24-1/4 118 0.92 Electric Tall 30 27 XE30T06ST45U1 21 46 47-1/2 50-3/8 19 92 0.92 Electric Tall 30 27 XE30T06ST38U1 17 36 47-1/2 50-3/8 19 92 0.92 Electric Medium 30 27 XE30M06ST45U1 21 45 37-1/2 40-1/2 20-1/4 92 0.90 Electric Short 30 27 XE30S06ST45U1*21 46 30 32 19-3/4 95 0.92 Electric Short 30 27 XE30S06ST38U1*17 33 30 32 19-3/4 95 0.92 Electric Short 28 25 XE28S06ST45U0 21 45 30 31-1/8 23 95 0.92 Electric Short 28 25 XE28S06ST38U0 17 45 30 31-1/8 23 95 0.92 Electric Short 20 N/A XE20S06ST38U0 17 N/A 31-1/2 31-1/2 17 62 N/A **Recovery = wattage/2.42 x temp. rise °F.Example: 4500W = 21 GPH 2.42 x 90° **Recovery = wattage/2.42 x temp. rise °F.Example: 3800W = 17 GPH 2.42 x 90° * Water heater dimensions prior to installing insulation blanket that is included with water theater. The blanket adds 1-1/2 inches to tank height and 2 inches to tank diameter.Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements. • All models equipped with heat traps. * *Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation. CDIAMETER AB HOTWATERCONNECTION COLDWATERCONNECTION ANODEROD RELIEF VALVECONNECTION 8" WATER CONNECTIONS ALL 3/4" N.P.T. ®Electric Specifications 08/20 FORM NO. THD-PE06 N Rev. 6 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com