HomeMy WebLinkAbout18111 Cambridge Dr_BLD5126_2023_Withdrawn
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551
Page 1 of 1
Permit Number: Permit Type:
Address/Parcel: Completed (Month/Year):
Land Use
Notice of Decision
Staff Report
Application
Narrative
Legal Description
Vicinity Map
Site Plan
Landscape Plan
Complete Streets Checklist
Traffic Impact Analysis
Snohomish County Traffic Mitigation Offer
WSDOT Traffic Offer Form
Tree Survey
Stormwater Drainage Report
Geotech Report
Critical Area Evaluation Form
SEPA Checklist
Public Notice Material
Noticing and Related Documents
Water / Sewer Availability Certificate
Unanticipated Discovery Plan Form
Aerial Photo of Site
Proposed Building Materials
Lighting Plans and Lighting Cut Sheets
Color Elevations
Design Matrix
Plat Map
Title Report
Lot Closures
Preliminary Civil Plans
Archaeological Survey
o Confidential Documents. Contact the
City to obtain.
Topography (Existing Conditions)
CC&R’s
Deeds / Easements / Conveyances
/Dedications
Developer’s Agreement
Recorded Copies
Bonding or Assignment of Funds
o Confidential Documents. Contact the
City to obtain.
Letters and Project Documents
Other:
Civil
Issued Permit
Application
Other Applications
Construction Calculation Worksheet
Approved Plans
Review Comment Form
Letters and Project Documents
Other Agency Permits
Reports:
o Drainage Report Pg:
o Stormwater Pg:
o Geotech Pg:
o All Other Reports
SEPA and Noticing Materials
Inspections
As-Builts
Other:
Building
Issued Permit
Application
Additional Applications
Approved Plans
Site Plan
Letters and Project Documents
Calculations
Project Specification Manuals
Reports
Certificate of Occupancy
Inspections
Other:
BLD5126 Residential Plumbing
18111 Cambridge Dr WITHDRAWN January 2023
✔
✔
18111 C am bridge D r 2300
00866600000400
RE P L AC IN G GAS WATE R H E ATE R
D iane M ason (206)724-7614
dmason206@ gmail.com
✔
(206)724-7614
18111 C am bridge Dr Arlington WA 98223
WAS H IN GTON E N E RG Y S E RVIC E S
P E RM ITS @ WAS H IN G TON E N E RGY.C OM
3909 196th S t S W LY N N WOOD WA 98036
WAS H IE S 796N U 10/25/2023
50
150
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
25
0
Professional Achiever® Atmospheric gas
water heaters are engineered for more
hot water at a low operating cost
Professional Achiever
Atmospheric
29, 30, 40 and
50-Gallon Capacities
Up to 40,000 BTU/h
Natural and LP Gas
See specifications chart on back.
Ruud Residential Gas Professional Achiever
Atmospheric Water Heaters
Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com
PRINTED IN U.S.A. 12/17 WP FORM NO. PROG RU N Rev. 3
Efficiency
• .58 - .66 UEF
• More hot water at a low operating cost
Performance
• FHR: 51 - 87 gallons
• Recovery: 30.3 to 40.4 GPH at a
90° F rise, depending on model
Guardian System™ & Sensor
• Exclusive air/fuel shut-off device
• Maintenance free – no filter to clean
• Protective control system that
disables the heater in the presence of
flammable vapor accumulation
Low Emissions
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx requirements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Altitude Certification
• All models certified up to 5,999 feet
above sea level, some certified up
to 10,000 feet. Consult factory for
specifications
Plus…
• Easy to light – no matches required
• EverKleen™ patented system fights
sediment build-up
• Exclusive Ruudglas® tank lining resists
corrosion and prolongs tank life
• Enhanced flow brass drain valve
• Temperature and pressure relief valve
included
• Low lead compliant
• Standard replacement parts
Warranty
• 6-Year limited tank and parts
warranty*
• With ProtectionPlus™ the 6-year limited
tank warranty becomes 10-year
* See Residential Warranty Certificate for
complete information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
† LEED Point = 1
Maintenance Free
Flame Arrestor PlateCombustion Shut-off System
Ruud Residential Gas Professional Achiever
Atmospheric Water Heaters
Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com
PRINTED IN U.S.A. 12/17 WP FORM NO. PROG RU N Rev. 3
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
2
†LEED Point = 1
E
G
BA
C
F
HHOTWATERCONNECTION
HCOLDWATERCONNECTION
D
1/2"
3/4" N.P.T.RELIEF VALVEOPENING
FLUE ANODE ROD
Specifications
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES)ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
GAS INPUT
IN THOUS.
BTU/H
RECOVERY
IN G.P.H.
90° F RISE
UEF
FIRST HR.
DEL. G.P.H.
HEIGHT
TO
VENT
A
TANK
HEIGHT
B
DIAM.
C
HT. TO
GAS
CONN.
D
VENT
SIZE
E
WATER
CONN.
CENTER
F
HT. TO
SIDE
T&P VALVE
G
WATER
CONN.
SIZE
H
SHIP
WT.
(LBS)
UNIFORM
ENERGY
FACTOR
(UEF)NAT.LP NAT.LP NAT.LP
Tall 29 28 PROG29-32N RU63 32 –32.3 –63 –59-3/4 56-7/8 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110 0.60
Tall 29 28 PROG29-30P RU63 –30 –30.3 –63 59-3/4 56-7/8 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110 0.60
Tall 40 38 PROG40-36N RU62†36 –36.4 –64 –61-1/2 58-1/2 19 14-1/4 3 or 4 8 52-1/4 3/4 127 0.58
Tall 40 38 PROG40-38N RU62†38 –38.4 –64 –61-1/2 58-1/2 19 14-1/4 3 or 4 8 52-1/4 3/4 127 0.58
Tall 40 38 PROG40-40N RU62†40 –40.4 –84 –63-1/4 60 19-1/2 14 3 or 4 8 53-1/2 3/4 135 0.66
Tall 40 38 PROG40-36P RU62†–36 –36.3 –84 63-1/4 60 19-1/2 14 3 or 4 8 53-1/2 3/4 135 0.66
Tall 40 38 PROG40-32P RU62†–32 –32.3 –67 61-1/2 58-1/2 18-1/2 14-1/4 3 or 4 8 52-1/4 3/4 125 0.59
Tall 50 48 PROG50-40N RU62†40 –40.4 –76 –62-1/2 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165 0.65
Tall 50 48 PROG50-36P RU62†–36 –36.4 –76 62-1/2 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165 0.65
Tall 50 48 PROG50-38N RU60†38 –38.4 –85 –61-1/4 58-3/8 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 150 0.64
Tall 50 48 PROG50-36P RU60†–36 –36.4 –85 61-1/4 58-3/8 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 150 0.64
Short 30 29 PROG30S-30N RU63 30 –30.3 –51 –49-7/8 47 19-3/4 14-1/4 3 or 4 8 40-3/8 3/4 112 0.60
Short 40 38 PROG40S-40N RU62†40 –40.4 –52 –53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58
Short 40 38 PROG40S-36P RU62†–36 –36.4 –52 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58
Short 40 39 PROG40S-38N RU62†38 –38.4 –65 –53-1/4 50-1/4 21-3/8 14-1/4 3 or 4 8 44 3/4 125 0.58
Short 40 39 PROG40S-35P RU62†–35 –35.4 –65 53-1/4 50-1/4 21-3/8 14-1/4 3 or 4 8 44 3/4 125 0.58
Short 50 48 PROG50S-40N RU61†40 –40.4 –87 –54-1/4 51-1/8 23-3/4 14-1/4 3 or 4 8 44 3/4 186 0.63
Short 50 48 PROG50S-36P RU61†–36 –36.4 –87 54-1/4 51-1/8 23-3/4 14-1/4 3 or 4 8 44 3/4 186 0.63