Loading...
HomeMy WebLinkAbout8400 207th Pl Ne_BLD6053_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD6053 Fire Sprinkler 8400 207th Pl Ne January 2025 ✔ ✔ ✔ ✔ ✔ CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSP ECTIONS: 360-403-3417 - Permit Center: 360-403-3551 B UILDING PERM IT 8400 207TH PL NE Parcel #: 31051200301600 Pe rmit #: 6053 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work: ADD AND RELOCATE FIRE SP RINKLERS FOR TENANT IMPROVEMENT AS NECESSARY Valuation: 16030.00 OWNER APPLICANT CONTRACTOR VENTAS CASCADE VALLEY LLC WESTERN STATES FIRE P ROTECTION/JACK HUFF Western States Fire Protection 7600 NE 41ST ST STE 330 14690 NE 95th St unit 101 14690 NE 95th St, Suite 101 VANCOUVER, WA 98662 Redmond Redmond , WA 98052 2062006649 425 881 0100 LIC: 601 049 394 EXP: 05/31/2025 LIC: WESTESF785LH EXP: 06/16/2026 MECHANICAL CONTRACTOR PLUM B ING CONTRACTOR LIC #:EXP:LIC #:EXP: JOB DESCRIPTION P ERMIT TYPE:FIRE SPRINKLER CODE YEAR:2021 STORIES:2 CONST. TYP E:VA DWELLING UNITS:OCC GROUP :I-1; Institutional BUILDINGS:OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO P ERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APP LICATION IS NOT A P ERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEP UTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUP Y A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 07/18/2024 Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections. Adhere to approved plans. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS P ERMIT AUTHORIZES ONLY THE WORK NOTED. THIS P ERMIT COVERS WORK TO BE DONE ON P RIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE P UBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEP ARATE PERMISSION. PERM IT FEES Date De s cription Fe e Amount 08/05/2024 Web Only - Fire System Plan Review $200.00 08/05/2024 Fire System Plan Review $71.70 08/05/2024 Credit Card Service $6.00 08/05/2024 Credit Card Service $2.15 08/05/2024 Processing/Technology $25.00 08/05/2024 Fire Sprinkler System $300.00 08/05/2024 Credit Card Service $9.75 Total Due :$614.60 Total Payme nt:$614.60 B alance Due :$0.00 CALL FOR INSPECTIONS Call by 3:30 pm for ne xt day ins pe ction, allow 48 hours for Fire Ins pe ctions Whe n calling for an ins pe ction ple as e le ave the following information: Pe rmit Numbe r, Type of Ins pe ction be ing re que s te d, and whe the r you pre fe r morning or afte rnoon INSPECTION INFORM ATION Pas s /Fail FIRE SPRINKLER PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 REV11.2020 Page 1 of 3 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: Complete and Scaled Plans Hydraulic Calculations Equipment Specifications for Each Fire Sprinkler Permit Application Specification Sheets Wiring Diagrams (Point to Point Wiring) Electrical Plans, if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 & over – based on project valuation (Plan Review Fee is 65% of project valuation as calculated per Table 4-1) Type of Permit:  New Installation System Modification Phased InstallationProperty Address: Suite No.: Lot #: Parcel ID No.: Project Valuation: Preferred Contact:  Owner  Applicant ContractorProject Description: Owner Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Applicant Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: REV2022 Page 2 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application – review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test (1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $600.00 + $ = $ Hydraulically Designed Systems Yes  / No  Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices** Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $625.00 + $ = $ Hydraulically Designed Systems Yes  / No  Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ RESIDENTIAL (NFPA 13D) Number of Devices** Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ * NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 3 of 3  HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I – new or existing x $150.00 = $ Class II – new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ SPRAY BOOTHS (105.7) & INDUSTRIAL OVENS (105.7.7) NOTE: SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Signature Print Name Date 14690 NE 95TH ST, UNIT 101 REDMOND, WA 98052 (425) 881-0100 ● (425) 881-3030 WWW.WSFP.COM Fire Protection • Suppression • Detection Systems Engineering • Installation • Service • Inspection Commercial • Industrial • Residential • Institutional Special Hazards • High Tech • Defense • Hangars Retrofit • Maintenance 3-D / BIM DESIGN Albuquerque, NM Austin, TX Casper, WY Colorado Springs, CO Dallas, TX Decatur, IL Denver, CO El Paso, TX Ft. Collins, CO Glenwood Springs, CO Houston, TX Jefferson City, MO Kansas City, KS Lakewood, CA Las Vegas, NV Los Angeles, CA Missoula, MT Phoenix, AZ Portland, OR Rapid City, SD Sacramento, CA San Antonio, TX Seattle, WA Spokane, WA St. Louis, MO Tucson, AZ Waco, TX OUR MISSION: QUALITY SOLUTIONS FOR THE PROTECTION OF LIVES AND PROPERTY, PROVIDING AN EXCEPTIONAL VALUE TO OUR CUSTOMERS. USGBC AND RELATED LOGO IS A TRADEMARK OWNED BY THE U.S. GREEN BUILDING COUNCIL AND IS USED BY PERMISSION 6/24/24 Subject: Cascade Valley To Whom It May Concern: Fire sprinkler hydraulic calculations will not be required for this project as sprinklers are being added and relocated while maintaining the requirements of NFPA 13 2019 ED section 27.5. Please contact me with any questions or concerns. Anthony Geist Design Manager (425) 881-0100 anthony.geist@wsfp.us ANTHONY MICHAEL GEIST 6781-0715-C LEVEL 3 WESTERN STATES FIRE PROTECTION COMPANY WESTESF785LH 06/24/2024 14690 NE 95th Street, Unit 101 Redmond, WA 98052 WA CL# WESTESF136QF FIRE SPRINKLER MATERIAL SUBMITTAL Model F1FR56 UprightModel F1FR56 Pendent Model F1FR56 Horizontal Sidewall Model F1FR56 Vertical Sidewall Note: Not all versions of the product are shown. F1FR Series Sprinkler Summary Sprinkler Model K-Factor gpm/psi1/2 (lpm/bar1/2)Orientation Listings & Approvals Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) F1FR56 5.6 (80) Upright Intermediate Upright cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1425 Pendent cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Concealed Pendent cULus, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Horizontal Sidewall cULus, FM 175 (12)RA1435 Vertical Sidewall cULus, FM, LPCB, UKCA 175 (12)RA1485 Table A Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix “N” in the order. Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. www.reliablesprinkler.com K-factor 5.6 (80) F1FR56 Series Quick Response Sprinklers Bulletin 074 January 2024 Model F1FR56 Upright Sprinkler SIN RA1425 Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045 Model F1FR56 Upright Sprinkler Components and Dimensions Figure 1 Deflector Glass Bulb (3 mm) Wrench Flat Threads 1 3/8" [33mm] 3 1/4" [83mm] Cap/Seal Assembly Load Screw 2 1/4" [58mm] F1FR_HALF_UPR_INT Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Bulletin 074 January 2024 Page 2 of 9 www.reliablesprinkler.com Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings(1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(2), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard in- stalled) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045, 0831-UK- CA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 F1FR_HALF_PEND_INT Deflector Glass Bulb (3 mm) Wrench Flat Threads 3 1/4" [83mm] 2 1/4" [57mm] 1" [25mm]Load Screw Cap/Seal Assembly Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 January 2024 Page 3 of 9 www.reliablesprinkler.com Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons(2) Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(3) F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(3) C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non-recessed) Model W4 (recessed) Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals cULus Listed(4) FM Approved(5) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 Bulletin 074 January 2024 Page 4 of 9 www.reliablesprinkler.com F1FR_HALF_HSW 2 3/4" [70mm] 1 1/8" [28mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Note: Please refer to Figure 9 for recessed installation. Model F1FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals(1) cULus Listed FM Approved LPCB(2) UKCA: 0832-UKCA-CPR-S5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1FR56 Vertical Sprinkler Components and Dimensions Figure 4 Bulletin 074 January 2024 Page 5 of 9 www.reliablesprinkler.com F1FR_HALF_VSW 2 1/4" [57mm] 1 1/2" [38mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. Minimum Recess Maximum Recess 1" (25 mm) Face of Fitting to Face of Ceiling 1-1/8" (29 mm) at Max. Recess 3/8" (10 mm) at Min. Recess Models F1 & F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-3/16" (78 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) Minimum Recess Maximum Recess 1-1/4" (32 mm) Face of Fitting to Face of Ceiling 7/8" (22 mm) at Max. Recess 3/8" (10 mm) at Min. Recess 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. 2-1/2" (64 mm) Dia. Hole in Ceiling Models F1 & F1FR Pendent Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Reducing Fitting Reducing Fitting Reducing Fitting Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Model F1FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-5/16" (84 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-1/2" (64 mm) Dia. Hole in Ceiling F1_REC_PEND_CCP Reducing Fitting Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. Vented Cup Recessed and Concealed Installation: Pendent Sprinklers Figure 5 FP EscutcheonF1 Escutcheon (F2 Similar) CCP Cover Plate Bulletin 074 January 2024 Page 6 of 9 www.reliablesprinkler.com 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) Dia. 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) DIA. 2-7/8" (73 mm) Dia. 2-7/8" (73 mm) Dia. 2-1/8" (54 mm) Minimum Recess 1-5/8" (42 mm) Maximum Recess 2 1/8" (54 mm) Minimum Recess 1-3/8" (35 mm) Maximum Recess 2-5/8" (67 mm) Dia Hole. 2-5/16" (58 mm) Dia. 3-1/4" (83 mm) Dia. 1-1/4" (32 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1-3/8" (35 mm) Minimum Recess 7/8" (22 mm) Maximum Recess 3/8" (16 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1/2" (12 mm) +/- 3/8" (10 mm) Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling F1FR_REC_HSW Reducing Fitting Reducing Fitting Reducing Fitting 9/16" [14mm] Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F2 Recessed escutcheon 1/2" (13 mm) Adjustment F1 Recessed escutcheon 3/4" (19 mm) Adjustment 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Recessed Installation: Horizontal Sidewall Sprinklers Figure 6 Bulletin 074 January 2024 Page 7 of 9 www.reliablesprinkler.com Installation Model F1FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N.m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2)Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4)Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5)Satin Chrome Satin Chrome White Polyester(3)White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Finishes(1)Table B Maintenance Reliable Model F1FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Wrenches Model W4 (recessed, concealed pendent) Model W2 (upright, pendent) Model W13 (Legacy frame with guard installed) Model W14 (New frame with guard installed) Bulletin 074 January 2024 Page 8 of 9 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 6 2 3 Bulletin 074 January 2024 Page 9 of 9 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model W14 (New frame with guard installed) • Model W13 (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. Series AH2-CC 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. Connections • From Branchline • ¾"/20mm BSPT female thread (VdS only) • 1 ¼"/32mm BSPT female thread (LPCB only) • 1"/25mm NPT or BSPT female Thread • 1"/25mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) • No. 116 CPVC Adapter (1"/25mm Female CPVC Socket x 1"/25mm Grooved IGS) • No. 142 Welded Outlet • Style 922 Outlet-T • Style 920N Mechanical-T Outlet • No. 65 Grooved End of Run Fitting • Hose Inlet • 1"/25mm Grooved IGS • 1"/25mm NPT or BSPT male thread • ¾"/20mm BSPT male thread (VdS only) • 1 ¼"/32mm BSPT male thread (LPCB only) Victaulic® VicFlex™ Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85 1 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 2 victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) • Sprinkler Reducer • Sprinkler Connection: 1/2" and ¾"/15mm and 20mm NPT or BSPT female thread • Straight Lengths: 5.75", 9", 13"/140mm, 230mm, 330mm • 90˚ Elbows • Standard Short • Low Profile Short • Standard Long • Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB10 for Armstrong® TechZone™ ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4"/100mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature • 225°F/107°C • 150°F/65°C (No. 116 CPVC Adapter) Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) • 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius • 7"/178 mm (FM/CCCf Approval) • 2"/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Maximum Allowable Sprinkler K-Factors • FM (1/2"/15 mm reducer) K5.6/8,1 (S.I.), (¾"/20 mm reducer) K14.0/20,2 (S.I.) • cULus (1/2"/15 mm reducer) K8.0/11,5 (S.I.), (¾"/20 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2"/15 mm reducer) K5.6/8,1 (S.I.), (¾"/20 mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS LPS 1261: Issue 1.2 Cert/LPCB Ref. 104l/01 104l/04 NOTE • The VicFlex Series AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® CPVC Products and is therefore covered under the Spears® FlameGuard® Installer Protection Plan. 3.0 SPECIFICATIONS – MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 Grade “E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 4 victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose B 371 2 4685 9 A Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve 9 Reducer Hose Length Dimensions Hose Length A B inches mm inches mm inches mm 31 790 25.3 641 31 790 36 915 31.3 794 36 915 48 1219 42.3 1073 48 1220 60 1525 54.3 1378 60 1525 72 1830 66.3 1683 72 1830 Series AH2-CC Braided Hose BA 3712 4 968 5 Hose Length A B inches mm inches mm inches mm 31 790 24.5 622 29.8 757 36 915 29.5 749 34.8 884 48 1219 41.5 1054 46.8 1189 60 1525 53.5 1359 58.8 1494 72 1830 65.5 1664 70.8 1798 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 9 Reducer 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 4.0 DIMENSIONS (CONTINUED) Standard Reducer 1234  5.75"/140 mm straight reducer Optional Reducers 9.0"/229 mm straight reducer 2.62"/ 66.5 mm 4.83"/ 122.7 mm 3.25"/ 5.50"/ 139.7 mm 6.57"/ 166.9 mm 66.5 mm 7.25"/ 184.2 mm 5.00"/ 127.0 mm 13.0"/330 mm straight reducer Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90° elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile 2.84"/ 72 mm 3.50"/ 89 mm1.88"/ 48 mm 1.4"/ 36 mm 1.4"/ 36 mm 4.59"/ 116 mm3.63"/ 92 mm 5.25"/ 133 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • Style AB11: When low profiles elbows are with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter E to E NOTES • E to E is 3.0"/76.0 mm • The No. 116 CPVC Adapter has 2 ft. (0.6 m) EQL of 1" Schedule 40 pipe. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 6 victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 • Surface Mount Applications • FM/LPCB Approved Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. 3 2 1 3 3 3 2 1 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. Style AB7 Adjustable • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) NOTE • Both sizes FM/VdS/LPCB Approved. 3 2 1 3 3 2 1 3 2 1 3 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 8 victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB10 • Suspended ceilings • Armstrong® TechZone™ Item Description 1 6"/152 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved, cULus listed. Style AB11 • Suspended ceilings • Hard-Lid ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS Approved, cULus listed. Style AB12 • Suspended ceilings • Hard-Lid ceilings Item Description 1 Style AB12 Bracket Body 2 #2 Square Drive Set Screw NOTE • FM/VdS Approved. 3 2 1 3 3 2 1 3 2 1 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 9 victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor-above mount • Cantilever mount • Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw, Serated Flange, M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body 5 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE • FM Approved. Style ABMM • Surface mount • Stand-off mount Item Description 1 Style ABMM Bracket Body 2 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE • FM Approved. 2 4 3 5 2 1 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 10 victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket R See Table L V2707 ¾"/19 MM MAX. RECESS V2707 MAX. EXTENSION 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/15.9 mm Typical ceiling tile See note Finished surface Bracket Assembly Style AB2 2⁄"/60.33 mm 2"/50.80 mm 4.3"/ 111 mm Hose Clearance Chart V2707 ¾" Max Recess V3802 ½" Max Recess V2707 ¾" Max Recess V3802 ½" Max Recess V2707 ¾" Max Recess V3802 ½" Max Recess V2707 ¾" Max Recess V3802 ½" Max Recess inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm "R" Minimum Bend Radius 2.0 50 3.0 80 7.0 175 – "A" Minimum Required Installation Space 8.6 218 10.1 269 9.6 244 11.1 281 13.6 345 15.1 383 5.8 147 5.8 147 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 11 victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket A See Chart V38 ½"/13 mm MAX. RECESS V38 MAX. EXTENSION 1.8"/45 mm Typical 16"/406 mm C/C /"/16 mm Typical drywall #10 Screw Finished ceiling Bracket Assembly Style AB2 2⁄"/68 mm max. hole 2⁄"/60 mm min. hole 3½"/ 89 mm R See chart 2" × 4" Stud Hose Clearance Chart Straight Reducer ¾" | 20 mm Max Recess" ½" | 13 mm Max Recess ¾" | 20 mm Sidewall ¾" | 20 mm Max Recess ½" | 13 mm Max Recess ¾" | 20 mm Sidewall ¾" | 20 mm Max Recess ½" | 13 mm Max Recess ¾" | 20 mm Sidewall inches mm mm mm mm mm mm mm mm mm "R" Minimum Bend Radius 2.0 50 3.0 80 7.0 175 "A" Minimum Required Installation Space 6.2 158 7.6 193 6.1 155 7.2 183 8.6 218 7.1 180 11.2 285 12.6 320 11.1 282 Hose Clearance Chart Long Elbow Short Elbow ¾" | 20 mm Max Recess ¾" | 20 mm Sidewall ½" | 13 mm Max Recess inches mm mm mm "R" Minimum Bend Radius – "A" Minimum Required Installation Space 3.3 84 3.6 91 3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 12 victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket R See chart A See Chart V27 ¾"/19 mm MAX. RECESS V27 MAX. EXTENSION ⁄"/16 mm Typical drywall ⁄"/23 mm Typical 16"/406 mm C/C #10 Screw Typical Hat Channel grid Finished ceiling 2⁄"/60 mm max. hole 2"/51 mm min. hole 4.1"/ 104 mm Bracket assembly Style AB4 Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 ¾" Max Recess V3802 ½" Max Recess V2707 ¾" Max Recess V3802 ½" Max Recess V2707 ¾" Max Recess V3802 ½" Max Recess V2707 ¾" Max Recess V3802 ½" Max Recess inches mm mm mm mm mm mm mm mm "R" Minimum Bend Radius 2.0 50 2.0 50 3.0 80 3.0 80 7.0 175 7.0 175 – "A" Minimum Required Installation Space 8.8 224 10.2 259 9.8 249 11.2 285 13.8 351 15.2 386 8.0 203 5.9 150 NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 13 victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket A See chart Finished ceiling 2⁄"/60 mm max. hole /"/16 mm Typ. Drywall 2"/51 mmmin. hole3⁄"/92 mm Typical 16"/406 mm C/C 2.3"/ 57 mm V27 ¾"/19 mm MAX. RECESS 2" × 4"metal stud Bracket assembly Style AB5 V27 MAX. EXTENSION R See chart Hose Clearance Chart "V2707 ¾" | 20 mm Max Recess" V3802 ½" | 13 mm Max Recess V2709 ¾" | 20 mm Sidewall V2707 ¾" | 20 mm Max Recess V3802 ½" | 13 mm Max Recess V2709 ¾" | 20 mm Sidewall V2707 ¾" | 20 mm Max Recess V3802 ½" | 13 mm Max Recess V2709 ¾" | 20 mm Sidewall inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm "R" Minimum Bend Radius 2.0 50 3.0 80 7.0 175 "A" Minimum Required Installation Space 6.0 158 7.7 196 6.1 155 7.0 178 8.7 221 7.1 180 11.0 279 12.7 323 11.1 282 Hose Clearance Chart Long Elbow Low-Profile Long Elbow Short Elbow V2707 ¾" | 20 mm Max Recess V3802 ½" | 13 mm Max Recess V2709 ¾" | 20 mm Sidewall V3802 ½" | 13 mm Max Recess V3802 ½" | 13 mm Max Recess inches mm inches mm inches mm inches mm inches mm "R" Minimum Bend Radius – "A" Minimum Required Installation Space 3.5 89 4.9 124 3.6 91 2.9 74 3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 14 victaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) A See Chart See Note 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on center Finished ceiling face Bracket Assembly Style AB11 max. hole 2"/51 mm min. hole max. hole 2⁄"/60 mm min. hole 3.0"/ 76 mm /"/15.9 mm Typical ceiling tile V38V27Pendent Hose Clearance Chart Long Elbow Short Elbow V2707 ¾" | 20 mm Max Recess" V3802 ½" | 13 mm Max Recess inches mm mm "A" Minimum Required Installation Space 4.0 102 3.9 99 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 15 victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.75"/140 mm Reducer "A"See Table 1⁄ inch/ 29 mm Finished Face of /-inch/16-mmTypical Ceiling Unnished Ceiling Face "B" See Table ⁄ inch/3 mm V2707 ½"/12.7 mm MAX. RECESS V2707 ¾"/19 mm MAX. RECESS Unnished Ceiling Face R "A"See Table 1⁄ inch/29 mm Finished Face of /-inch/16-mmTypical Ceiling "B" See Table Nominal length 14"/355.6 mm ⁄ inch/3 mm Dimension Low Profile Short Elbow Low Profile Long Elbow Standard Short Elbow Standard Long Elbow Standard Straight Reducer ¾"/19 mm Recessed*Concealed ¾"/19 mm Recessed Concealed ¾"/19 mm Recessed Concealed ¾"/19 mm Recessed Concealed ¾"/19 mm Recessed Concealed inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm A Minimum Required Installation Space 4.0 101.6 5.5 139.7 5.6 142.2 7.2 182.9 5.9 149.9 7.5 190.5 7.7 195.6 9.3 236.2 15.0 381.0 16.6 421.6 B Distance from Top of Typical Ceiling Tile to Bottom of Gate 0.5 12.7 2.0 50.8 1.5 38.1 1.5 38.1 1.5 38.1 1.5 38.1 3.0 76.2 3.0 76.2 3.0 76.2 3.0 76.2 * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 3.93"/ 3.94"/ 100 mm 2.94"/ 75 mm 2.22"/ 56 mm 0.28"/ 7 mm 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 16 victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C B 3¾"/ 95.3 mm A 2⁄"/60 mm max. hole 2"/51 mm min. hole Hose Clearances Dimension inches mm mm mm mm mm mm mm mm mm mm Outlet Length "B" 5.75 146.1 9 228.6 13 330.2 5.75 146.1 9 228.6 13 330.2 9 228.6 13 330.2 13 330.2 13 330.2 5.75 146.1 9 228.6 13 330.2 5.75 146.1 9 228.6 13 330.2 9 228.6 13 330.2 13 330.2 13 330.2 Hose Clearance "C" 11.6 294 14.8 376 18.8 478 9.6 243 12.8 325 16.8 427 10.8 275 14.8 376 12.8 325 10.8 275 12.6 319 15.8 402 19.8 503 10.6 268 13.8 351 17.8 452 11.8 300 15.8 402 13.8 351 11.8 300 Bend Radius "R" 7 175 8 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 17 victaulic.com 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet RSee chart A See chart Style 922 Threaded Mechanical Tee Outlet 2"/50 mm R See chart A See chart Style 922 Grooved Mechanical Tee Outlet 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm mm mm mm mm mm mm mm mm mm R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 A Min.9.4 238 10.4 263 11.4 289 12.4 314 13.4 339 A Min.7.7 197 8.7 222 9.7 247 10.7 273 11.7 298 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 18 victaulic.com 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet Female Threaded Weld Outlet R See chart A See chart 2"/50 mm R See chart A See chart No. 142 Grooved Weld Outlet 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 3 80 4 100 5 125 6 150 7 175 A Min.9.4 239 10.4 264 11.4 290 12.4 315 13.41 341 A Min.8.1 205 9.1 231 10.1 256 11.1 281 12.1 307 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Length Nominal Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 pipe inches mm Type inches DN feet meters Max Bends 31 Straight 1/2 15.0 3790DN154.6 31 Straight 1/2 16.0 4790DN154.9 31 Straight 3/4 19.0 3790DN205.8 31 Straight 3/4 20.0 4790DN206.1 36 Straight 1/2 18.0 3915DN155.5 36 Straight 1/2 21.0 5915DN156.4 36 Straight 3/4 21.0 3915DN206.4 36 Straight 3/4 23.0 5915DN207.0 48 Straight 1/2 21.0 31220DN156.4 48 Straight 1/2 32.0 81220DN159.8 48 Straight 3/4 26.0 31220DN207.9 48 Straight 3/4 37.0 81220DN2011.3 60 Straight 1/2 27.0 31525DN158.2 60 Straight 1/2 46.0 101525DN1514.0 60 Straight 3/4 27.0 31525DN208.2 60 Straight 3/4 46.0 101525DN2014.0 72 Straight 1/2 31.0 31830DN159.4 72 Straight 1/2 55.0 121830DN1516.8 72 Straight 3/4 30.0 31830DN209.1 72 Straight 3/4 60.0 121830DN2018.3 19 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Hose Reducer UL Length Nominal Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 pipe inches mm Type inches DN feet meters Max Bends 31 LP Elbow 1/2 18.0 3790DN155.5 31 LP Elbow 1/2 24.0 4790DN157.3 31 LP Elbow 3/4 21.0 3790DN206.4 31 LP Elbow 3/4 24.0 4790DN207.3 36 LP Elbow 1/2 19.0 3915DN155.8 36 LP Elbow 1/2 26.0 5915DN157.9 36 LP Elbow 3/4 23.0 3915DN207.0 36 LP Elbow 3/4 28.0 5915DN208.5 48 LP Elbow 1/2 23.0 31220DN157.0 48 LP Elbow 1/2 43.0 81220DN1513.1 48 LP Elbow 3/4 30.0 31220DN209.1 48 LP Elbow 3/4 42.0 81220DN2012.8 60 LP Elbow 1/2 28.0 31525DN158.5 60 LP Elbow 1/2 49.0 101525DN1514.9 60 LP Elbow 3/4 31.0 31525DN209.4 60 LP Elbow 3/4 50.0 101525DN2015.2 72 LP Elbow 1/2 31.0 31830DN159.4 72 LP Elbow 1/2 65.0 121830DN1519.8 72 LP Elbow 3/4 36.0 31830DN2011.0 72 LP Elbow 3/4 63.0 121830DN2019.2 20 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius Length Nominal Outlet Size 1 Bend 2 Bends 3 Bends 4 Bends 5 Bends 6 Bends 7 Bends 8 Bends 9 Bends 10 Bends 11 Bends 12 Bends inches mm inches DN feet meters feet meters feet meters feet meters feet meters feet meters feet meters feet meters feet meters feet meters feet meters feet meters 31 1/2 11.0 13.0 15.0 16.0 ––––––––790 DN15 3.4 4.0 4.6 4.9 31 3/4 12.0 14.0 19.0 20.0 ––––––––790 DN20 3.7 4.3 5.8 6.1 36 1/2 14.0 16.0 18.0 19.0 21.0 –––––––915 DN15 4.3 4.9 5.5 5.8 6.4 36 3/4 17.0 19.0 21.0 22.0 23.0 –––––––915 DN20 5.2 5.8 6.4 6.7 7.0 48 1/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 ––––1220 DN15 5.5 5.8 6.4 7.0 7.6 8.2 9.1 9.8 48 3/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 ––––1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 60 1/2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 ––1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 ––1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 72 1/2 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 26.0 28.0 30.0 33.0 37.0 40.0 44.0 48.0 51.0 54.0 57.0 60.0 1830 DN20 7.9 8.5 9.1 10.1 11.3 12.2 13.4 14.6 15.5 16.5 17.4 18.3 NOTES • Values for use with 5.75"/140 mm straight reducers. • The values in this table are provided by the manufacturer for reference only. For friction loss data in accordance with the UL Certification, please refer to pages 19 and 20 of this publication. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 21 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178 mm Bend Radius inches mm Imperial S.I. inches mm type feet meters 31 790 5.6 8.1 1/2 15 Straight 13.8 4.2 21/2 15 90˚ Elbow 23.5 7.1 36 915 5.6 8.1 1/2 15 Straight 16.6 5.1 21/2 15 90˚ Elbow 25.6 7.8 48 1220 5.6 8.1 1/2 15 Straight 23.4 7.1 31/2 15 90˚ Elbow 30.7 9.3 60 1525 5.6 8.1 1/2 15 Straight 30.2 9.2 41/2 15 90˚ Elbow 35.9 10.9 72 1830 5.6 8.1 1/2 15 Straight 37.0 11.3 41/2 15 90˚ Elbow 41.1 12.5 31 790 8.0 11.5 3/4 20 Straight 16.8 5.1 23/4 20 90˚ Elbow 16.8 5.1 36 915 8.0 11.5 3/4 20 Straight 20 6.0 23/4 20 90˚ Elbow 19.7 6.0 48 1220 8.0 11.5 3/4 20 Straight 27.8 8.4 33/4 20 90˚ Elbow 26.6 8.1 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 22 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178 mm Bend Radius inches mm Imperial S.I. inches mm type feet meters 60 1525 8.0 11.5 3/4 20 Straight 35.7 10.9 43/4 20 90˚ Elbow 33.6 10.2 72 1830 8.0 11.5 3/4 20 Straight 43.5 13.2 43/4 20 90˚ Elbow 40.6 12.2 31 790 11.2 16.1 3/4 20 Straight 16.5 5.0 23/4 20 90˚ Elbow 17.8 5.4 36 915 11.2 16.1 3/4 20 Straight 19.5 5.9 23/4 20 90˚ Elbow 20.7 6.3 48 1220 11.2 16.1 3/4 20 Straight 26.7 8.1 33/4 20 90˚ Elbow 27.9 8.5 60 1525 11.2 16.1 3/4 20 Straight 33.9 10.3 43/4 20 90˚ Elbow 35 10.7 72 1830 11.2 16.1 3/4 20 Straight 41.3 12.5 43/4 20 90˚ Elbow 42.2 12.8 31 790 14.0 20.2 3/4 20 Straight 14.9 4.5 23/4 20 90˚ Elbow 15.5 4.72 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 23 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178 mm Bend Radius inches mm Imperial S.I. inches mm type feet meters 36 915 14.0 20.2 3/4 20 Straight 19.4 5.9 23/4 20 90˚ Elbow 19.6 5.9 48 1220 14.0 20.2 3/4 20 Straight 30.3 9.2 33/4 20 90˚ Elbow 29.5 8.9 60 1525 14.0 20.2 3/4 20 Straight 33.9 10.3 43/4 20 90˚ Elbow 34.1 10.4 72 1830 14.0 20.2 3/4 20 Straight 37.5 11.4 43/4 20 90˚ Elbow 38.6 11.7 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 24 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.2 PERFORMANCE – FRICTION LOSS DATA Series AH2 Braided Hose with 90° Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178mm Bend Radius inches mm Imperial S.I. inches mm feet meters 31 790 5.6 8.1 1/2 15 13.7 4.2 2 36 915 5.6 8.1 1/2 15 17.0 5.2 2 48 1220 5.6 8.1 1/2 15 25.0 7.6 3 60 1525 5.6 8.1 1/2 15 33.0 10.1 4 72 1830 5.6 8.1 1/2 15 41.1 12.5 4 31 790 8.0 11.5 3/4 20 13.6 4.14 2 36 915 8.0 11.5 3/4 20 16.9 5.2 2 48 1220 8.0 11.5 3/4 20 27.8 8.5 3 60 1525 8.0 11.5 3/4 20 32.6 9.9 4 72 1830 8.0 11.5 3/4 20 40.6 12.4 4 31 790 11.2 16.1 3/4 20 13.7 4.2 2 36 915 11.2 16.1 3/4 20 17.0 5.2 2 48 1220 11.2 16.1 3/4 20 24.9 7.6 3 60 1525 11.2 16.1 3/4 20 32.9 10.0 4 72 1830 11.2 16.1 3/4 20 40.9 12.5 4 31 790 14.0 20.2 3/4 20 13.5 4.1 2 36 915 14.0 20.2 3/4 20 16.8 5.1 2 48 1220 14.0 20.2 3/4 20 24.7 7.5 3 60 1525 14.0 20.2 3/4 20 32.7 9.9 4 72 1830 14.0 20.2 3/4 20 40.7 12.4 4 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 25 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.3 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Style AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25)Maximum Number of 90º Bends at 3"/76.2 mm Bend Radius mm inches DN inches meters feet 790 31 DN15 5.5 18.0 31/2 DN20 3/4 915 36 DN15 6.4 21.0 31/2 DN20 3/4 1220 48 DN15 8.5 27.9 31/2 DN20 3/4 1525 60 DN15 10.7 35.1 41/2 DN20 3/4 1830 72 DN15 12.8 42.0 41/2 DN20 3/4 VdS Ceiling Manufacturers List AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1. AMF 2. Armstrong 3. Chicago Metallic 4. Dipling 5. Durlum 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn No specific approval 1. Hilti 2. Knauf 3. Lafarge 4. Lindner 5. Rigips 26 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.3 PERFORMANCE – FRICTION LOSS DATA LPS 1261: Issue 1.2 Cert/LPCB Ref. 104l/01 104l/04 Series AH2 and AH2-CC Braided Hose Style AB2, AB3, AB4, AB5, AB7, AB8, and AB10 Brackets Series AH2 Braided Hose Style AB2, AB3, AB4, AB5, AB7, AB8, AB10 and AB12 Brackets Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) Maximum Number of 90º Bends at 3"/76.2 mm Bend Radius Length of Flexible Hose Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Straight Configuration Bend Configuration mm inches mm inches type meters feet mm inches meters feet meters feet 790 31 15 mm 1/2 Straight 1.8 6.0 2 790 31 0.87 2.9 2.70 8.920 mm 3/4 Straight 915 36 15 mm 1/2 Straight 3.6 11.9 3 915 36 1.00 3.3 2.80 9.220 mm 3/4 Straight 1220 48 15 mm 1/2 Straight 4.3 14.0 3 1220 48 2.23 7.3 4.66 15.320 mm 3/4 Straight 1525 60 15 mm 1/2 Straight 4.1 13.6 3 1525 60 2.90 9.5 6.5 21.320 mm 3/4 Straight 1830 72 15 mm 1/2 Straight 5.5 18.1 3 1830 72 3.31 10.9 7.16 23.520 mm 3/4 Straight CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 27 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depres- surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. • It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer’s warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall) will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. 28 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 7.0 REFERENCE MATERIALS – CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Model Size Actual Length Total Load Max. Uniform Load ft m lb N lb/linear ft N/linear m 31/790 2.6 0.8 5.2 23 2.6 38 36/915 3 0.9 5.5 25 2.8 40 48/1220 4 1.2 6.3 28 3.1 46 60/1525 5 1.5 7.0 31 3.5 51 72/1830 6 1.8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Model Size Actual Length Total Load Max. Uniform Load ft m lb N lb/linear ft N/linear m 31/790 2.6 0.8 6.1 27 1.5 22 36/915 3 0.9 6.4 29 1.6 23 48/1220 4 1.2 7.2 32 1.8 26 60/1525 5 1.5 7.9 35 2.0 29 72/1830 6 1.8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Suspension System Actual Length Min. Allowable Uniform Load ft/m lb/linear ft N/linear m Direct Hung Light 5.0 75.7 Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 29 victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4, I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 7.0 REFERENCE MATERIALS – CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 90° Minimum bend radius Minimum bend radius Minimum bend radius 2X Minimum bend radius OR Minimum bend radius Minimum bend radius Minimum bend radius 2X Minimum bend radius Minimum bend radius OR NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB5 I-VicFlex-AB7 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM I-RES 30 victaulic.com