4011 172ND ST NE_BLD4199_2026
s Fire Systems West, Inc. 206 FRONTAGE ROAD NORTH, SUITE C PACIFIC, WA 98047 (253) 833-1248 s FIRE ALARM Equipment Submittal FOR Smokey Point MOB 4011 172"d Street NE Arlington, WA 98223 Honeywell FarenhytT' Series THE POWER OF CONNECTED IFP-2100 / IFP-2100B / RFP-2100 / RFP-2100B Scalable Analog/Addressable Fire Alarm Control System The IFP-2100(red)and IFP-2100B(black)are intelligent analog/ addressable Fire Alarm Control Panels(FACP).The basic IFP-2100 panel contains one built in signaling line circuit(SLC),which can support 159 System Sensor'IDP/SK sensors and 159 IDP/SK modules or 127 Hochiki° SD devices per loop.Additional SLC loops can be added using the model IFP-2100B 6815 SLC expander for IDP/SK devices to increase the overall point capacity to 2100 or model 5815XL for SD devices to increase the overall point capacityto a maximum to 2032 points per panel. IFP-2100 has the interconnection capability for up to 32 panels.The system has two modes of operation,multiple panels covering one larger building,or multiple independent buildings.The RFP-2100(red)or RFP-2100B(black) can be used in a networked system where at least one IFP-2100 is in the system.It is the same as the IFP-2100 withoutthe display. IFP-2100 has eight on-board FlexputTm circuits that can be configured for auxiliary power,notification outputs,or for conventional smoke detector inputs(Class A or Class B).The FACP also has a Built in dual phone line digital alarm communicator/transmitter(DACT),I or optional cellular RFP-2100B technologies,Form C trouble relay,and two programmable Form C relays. IFP-2100 has powerful features such as detector sensitivity,day/night thresholds,drift compensation,pre-trouble maintenance alert,and calibration trouble alert FEATURES & BENEFITS • RFP-2100 or • Four line LCD display Network card allows • JumpStart Supports up to four RFP-2100B can be with 40 characters per copper network Auto Programming® SWIFTwireless used in a networked line connection with a feature for easy gateways.Each system where at lease . Available in a red or multi-mode or programming gateway can have up one IFP-2100 is in the black cabinet single-mode fiber . Renewable license on to 49 wireless devices system connection option • IFP-2100 or downloading software • Supports Class B • Network support for RFP-2100 can be Built-in dual phone helps inhibit (Style 4)and Class A up to 32 Sites surface or flush line,digital alarm unauthorized (Style 6 or Style 7 • Built-in support for up mounted communicator/ programming configuration for SLC, transmitter(DACT),IP and SBUS. to 159 IDP/SK Built in USB interface • Four programmable or optional cellular detectors and 159 function keys for programming IDP s/SK modules or y technologies 127 SD SLC devices IFP-2100 / RFP-2100 Technical Specifications PHYSICAL listing of the IDP,SK,SWIFT or SD devices. For a complete listing of all Overall Dimensions:26.4"H x 16.4"W x4.11"D 3350361:IDP Device Protocol data sheet compliance approvals and certifications,please visit Shipping Weight:33 lbs. 53623:SK Device Protocol data sheet www.farenhyt.com. Color:Red or Black 350360:SD Device Protocol data sheet 350615&350617:SWIFT devices data sheet Microsoft,Windows,and ENVIRONMENTAL the Windows Logo are registered trademarks Operating Temperature:320Fto 120°F (0°C to ORDERING INFORMATION or trademarks of 49°C) IFP-2100:Intelligent Fire Alarm Control Panel.Red Microsoft Corporation. Humidity:0 to 93%relative humidity(non- Cabinet. SWIFT*and Honeywell' condensing) IFP-2100B:Intelligent Fire Alarm Control Panel. are registered trademarks Black Cabinet. of and Farenhyt-is a ELECTRICAL IFP-2100HV:High Voltage(240V)Intelligent Fire trademark of Honeywell IFP-2100 Primary AC:120VAC @ 50/60Hz,4.5A Alarm Control Panel.Red Cabinet International,Inc. IFP-210OHV AC:240VAC C 50/60Hz,2.8A IFP-21O0HVB:High Voltage(240V)Intelligent Fire This document is not Total Accessory Load:9A @ 24VDC power-limited Alarm Control Panel.Black Cabinet intended to be used for Standby Current:230mA RFP-2100:Remote Fire Alarm Panelwithout built installation purposes.We Alarm Current:415mA in display.Red Cabinet. tryto keep our product RFP-21OOB:Remote Fire Alarm Panel without built information to Battery Charging Capacity:17 to 55AH date and accurate.We Battery Size:18AH max.allowed in control panel in display.Black Cabinet. cannot cover all specific cabinet.Larger capacity batteries can be housed in RFP-21O0HV: High Voltage(240V)Remote Fire applications or anticipate RBB accessory cabinet. Alarm Panel without built in display.Red Cabinet. all requirements.All Six Conductor Wiring:Two voice bus&four SBUS RFP-21O0HVB: High Voltage(240V)Remote Fire specifications are subject Alarm Panelwithout built in display.Black Cabinet. to change without notice. FLEXPUT CIRCUITS For Technical Eight circuits that can be programmed SBUS ACCESSORIES Support,Please call individually as: RA-2000,RA-1000,RA-1000R,RA-100, 800-446-6444. Notification Circuits:3A per circuit C 24VDC, RA-2000GRAY:Remote annunciators power limited 6815:Signal Line Circuit(SLC)Expander for IDP or Auxiliary Power Circuits:3A per circuit C 24VDC, SK devices power limited. 5815XL:Signal Line Circuit(SLC)Expander for SD Initiation Circuit:100mA per circuit C 24VDC, devices power-limited RPS-1000/13:Power Supply.Red or Black Cabinet 5496:NAC Expander AGENCY LISTINGS AND APPROVALS 5824:Serial/Parallel Module NFPA 13,NFPA 15,NFPA 16,NFPA 70,&NFPA 5880:LED 1/0 Module 72:Central Station;Remote Signalling;Local 5865-3 or 5865-4:LED Annunciator Protective Signalling Systems;Auxiliary Protected 5883:Relay Interface Premises Unit;&Water Deluge Releasing Service UL Listing MISCELLANEOUS ACCESSORIES CSFM 7165-0559:0505 HFSS:Software Suite.Provides programming, FDNY COA#6251 upload/download and event reporting Seismic(CA)(pending) RBB:Remote Battery Box Cabinet.Use for backup FM approved batteries up to 35AH.Dimensions:16"W x 10"H x 6"D APPROVED RELEASING SOLENOIDS SK-SCK:Seismic Compliance Kit Asco T8210A107 24 VDC 3 A max 0 Hz SK-NIC:Network Interface Card Asco 8210G207 24 VDC 3 A max 0 Hz SK-FML:Multi Mode Fiber Card COMPATIBLE DEVICES SK-FSL:Single Mode Fiber Card CELL-MOD:Cellular Communicator in Plastic See the data sheets listed below for a complete Enclosure CELL-CAB-SK:Cellular Communicator in Metal For more information Enclosure with lock and key Learn more about Honeywell's Farenhyt Series and other products available by visiting www.fa ren hyt.com> Honeywell Farenhyt 12 Clintonville Road Northford,CT 06472 3516021 A 101/18 Honeywel l 800-328-0103 ©2018 Honeywell International Inc. aes-corp.com of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights i • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options �L • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies(MCT)feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D _ Subscriber ----'--------- / 1 1 C B)Fire / / ` Subscriber / _ AES-Network Management System B ———————————— Primary AES-Mul[iNe[Receiver � I A)Alarm Panel Secondary AES-MUIt Net Receiver / � I 0 :C Alarm Automation p ———-_— --- C)IPLinks Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel&AES Subscriber Multi-path AES-IntelliNet@ Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units.A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire InteffiNet 2.0 Fire Subscribers 2.0 PREMIUM (UL& ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy . • - 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication 4+4:4 reverse polarity input and USB access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-IntelliPro for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem IIla2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop, or PC ANTENNA Receiving Centres and Systems 2.5dB tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+ charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60oC) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. f in 0 v o www.aes-corp.com AES Corporation 1 285 Ne • Peabody, MA 01960 United States O Copyright 2018AES • •• • • S are registered trademarks of AES Corporation SILENT Farenhyt KNIGHT by Honeywell AnnunciatorRemote Remote Annunciator Agency Listings RA-1000 M EA O US ` F M FR vI APPROVED 429-92-E Vol Ix The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of r the IFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power 0 LED is lit and all other LEDs are off. The other LEDs turn on ©� ® '�p as alarms, supervisories, troubles, system silenced and AC c�u cs Q ® 00 V 0 power losses occur. v00 ■ Features • 80-character backlit LCD display (4 lines with 20 characters on each line) RA-1000 • Tactile and audible feedback • Accepts user codes or fire fighter's key Installation • Larger keypad buttons for system reset and silence The RA-1000 can be surface or flush • RS-485 interface to panel mounted. Use the optional trim ring for surface • Operation and appearance is identical to IFP-1000 built-in mounts. When flush mounting an electrical annunciator box is optional. If using an electrical box, use • Install up to eight RA-1000s per FACP a 4S, single-gang, or double-gang box. • Support for simultaneous use of multiple RA-1000s Compatibility • On-board piezo sounder audibly indicates alarms, troubles, The RA-1000 is compatible with the following and supervisories FACPs: • Five status LEDs for alarm, supervisory, trouble, silence and . IFP-1000ECS Emergency Communication AC power conditions System with Fire Alarm Control Panel • Available in red or light gray • IFP-100ECS Emergency Communication • Wiring lengths up to 6000 ft. from the FACP (depending on System and Fire Alarm Control Panel wire gauge and number of devices on SBUS) • IFP-1000 Intelligent Fire Panel • UL listed, complies with NFPA 72 • IFP-100 Intelligent Fire Panel • CSFM approved • IFP-50 Intelligent Fire Panel • M EA P/N 350071 Rev D Copyright©2012 Honeywell International Inc. FlexputT"is a Trademark of Silent Knight Jumpstart®is a Registered Trademark of Silent Knight IFP-1000 FACP RA-100apD0 RA-1000 RA-1000 vv� ovo o° o o v �C2o��a� 110. uuu � I o�u � avo • Up to 8 RA-1000 per system •80-character backlit LCD display (4 lines with 20 characters each) •Wiring lengths up to 6000 ft. from the control panel Specifications Approvals Physical • NFPA 72 Height: 7.4" (18.8 cm) • UL Listed; Width: 9.1" (23.1 cm) • CSFM 7170-0559: 135; Depth: 1.5" (3.8 cm) • MEA 429-92-E Vol. IX; Shipping Weight: 2.8 Ibs (1.3 kg) • FM Approved Color RA-1000R: Red Ordering Information RA-1000: Gray RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Electrical Red. Operating Voltage: 24 VDC RA-1000 Remote Annunciator. Four line LCD Standby Current: 20 mA max annunciator with 20 characters per line. Alarm Current: 25 mA Gray. Accessories Wiring Distance: 6,000 max. from FACP (depending on wire 5860TR Red Trim Ring. For surface mounting. gauge and number of devices on the SBUS) 5860TG Gray Trim Ring. For surface mounting. Max Per System: 8 Environmental Operating Temperature: 320F— 120OF (0°C—49°C) Humidity: 10%—93% non-condensing SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or KNIGHT anticipate all requirements.All specifications are subject to change without notice. For 0 ' more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800)328-0103, Fax: (203)484-7118. www.farenhyt.com Made in the U.S.A. Honeywell FarenhytT" Series THE POWER OF CONNECTED Farenhyt IDP-PHOTO-W Series Intelligent Plug-in Photoelectric Smoke Detectors Honeywell's IDP-PHOTO-W Series intelligent plug-in smoked etectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The IDP-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported - - to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. IDP-PHOTO-W in B300-6 base Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the IDP-PHOTO-T.The IDP-PHOTO-R is a remote test capable detector for use with DNR Series duct detector housings FEATURES & BENEFITS • New modern profile • Optional remote, • Built-in tamper- • Optional relay, for improved single-gang LED resistant feature isolator,and sounder aesthetics accessory . Sealed against back bases • Stable communication • Dual LED design pressure • Plugs into separate technique with noise provides 360'viewing . Expanded color base for ease of immunity angle options installation and • Low standby current • Remote test feature maintenance • SEMS screws for • Two-wire SLC from the panel wiring of the separate connection • Built-in functional test base switch activated by external magnet DETECTOR SPACING AND IDP-PHOTO-R-W:White,low-profile ACCESSORIES APPLICATIONS intelligent photoelectric sensor,remote CK300:Color Kit(includes cover and Honeywell recommends spacing test capable.For use with DNR/DNRW.. trim ring),white,10-Pack. detectors in compliance with NFPA 72. IDP-PHOTO-R-IV:Ivory,low-profile CK300-IV: Color Kit(includes cover and In low airflow applications with smooth intelligent photoelectric sensor,remote trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m).For test capable.For use with DNR/DNRW. CK300-BL:Color Kit(includes cover and specific information regarding detector INTELLIGENT BASES trim ring),black,10-Pack. spacing,placement,and special M02-04-01:Detector test magnet. applications referto NFPA 72.System B300-6:White,standard flanged low-profile mounting base. M02-09-00:Telescoping test magnet. Smoke Detector Application Guide, document A05-1003,is available at B300-6-BP:Bulk pack of B300-6, RA10OZ:Remote LED annunciator systemsensor.com package contains 10. SMB600:Surface Mounting Kit B300-6-IV:Ivory,standard flanged (flanged). INSTALLATION low-profile mounting base. TR300:Replacement trim ring for B300- The IDP-PHOTO-W Series plug-in B501-WHITE:White,standard European 6,white. detectors use a separate base to simplify flangeless mounting base.UL listed. TR300-IV:Replacement trimring for installation,service,and maintenance. B501-BL:Black,standard European B300-6-IV,ivory. Installation instructions are shipped with flangeless mounting base.UL listed. each detector. B501-IV:Ivory,standard European Mount base(all base types)on an flangeless mounting base.UL listed. electrical backbox which is at least 1.5" B20OS-WH:White,Intelligent, (3.81 cm)deep. programmable sounder base. B20OS-IV:Ivory,Intelligent, NOTE: programmable sounder base. •Because of the inherent supervision B200SR-WH:White,Intelligent sounder provided by the SLC loop,end-of-line base for retrofit applications. resistors are not required.Wiring"T-taps" B200SR-IV:Ivory,Intelligent sounder or branches are permitted for Style 4 base for retrofit applications. (Class"B")wiring. B20OS-LF-WH:White,Low Frequency •When using relay or sounder bases, Intelligent,programmable sounder base. consult the installation sheet for device B20OS-LF-IV:Ivory,Low Frequency Limitations between isolator modules Intelligent,programmable sounder base. and isolator bases. B200SR-LF:White,Low Frequency Intelligent sounder base for retrofit ORDERING INFORMATION applications. NOTE:Detectors must be mounted to one B200SR-LF-IV:Ivory,Low Frequency of the Intelligent Bases listed below Intelligent sounder base for retrofit IDP-PHOTO-W:White,low-profile applications. intelligent photoelectric sensor. B224RB-WH:White,plug-in System IDP-PHOTO-IV:Ivory,low-profile Sensor relay base. intelligent photoelectric sensor. B224RB-IV:Ivory,plug-in System IDP-PHOTO-T-W:White,same as the Sensor relay base. IDP-PHOTO-W,but includes a built-in B224BI-WH:White,plug-in System 135°F(57°C)fixed-temperature thermal Sensor isolator detector base. device. B224BI-IV:Ivory,plug-in System Sensor IDP-PHOTO-T-IV:Same as IDP- isolator detector base. PHOTO-T but in Ivory. Farenhyt IDP-PHOTO-W Series Technical Specifications PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The IDP-PHOTO-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Farenhyt Series www.farenhyt.com. base 4.1"(104 mm)installed in B501 base FACPs: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) • 1 FP-2100/1 FP-2100ECS/RFP-2100 registered trademarks or trademarks of ENVIRONMENTAL • IFP-2000/IFP-2000ECS/RPS-2000 Microsoft Corporation. Operating Temperature range: • IFP-1000/I FP-1000ECS Honeywell'and System Sensor'are Photo:32°Fto 1220F(OoCto 50°C) • IFP-300/IFP-300ECS registered trademark Photo with Thermal:320F to 100°F(0°C to trademark andademaarkrk o of Honeywell is a • IFP-100/IFP-100ECS trf oneywell 380C) International,Inc. Thermal Ratings:Fixed Temperature Set point: • IFP-75 This document is not • IFP-50 intended to be used for 1350 F(570 C) installation purposes.We Sensitivity:U L Applications:0.5%to 4.0%per tryto keep our product AGENCY LISTINGS AND APPROVALS information up-to foot obscuration. date and accurate.We For exact certification listings for each model, cannotcover all specific ELECTRICAL RATINGS please reference the respective agency Web site. applications or anticipate all requirements.All Voltage Range:15 to 32VDC peak UL listed:S6173 specifications are subject to change without notice. Operating Current C 24VDC:200µA(one FM approved al communication every 5 seconds with green LED CSFM:7272-0559:0512 Support n lea Support,Please call blink on communication) 800-446-6444. Maximum Current:4.5mA @ 24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Farenhyt 12 Clintonville Road N o rthfo rd,CT 06472 Doc 351629 1 Rev Al 04/18 Honeywell 800-328-0103 ©2018 Honeywell International Inc. SILENT Farenhy KNIGHT by Honeywell Intelligent Device Addressable Monitor Module Agency Listings IDP-Monitor 'STMc MEA UL The IDP-Monitor is an addressable monitor module for use with sOw �RvSG 386 0 E-Vol 2 Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Monitor acts as an interface to contact devices, such as waterflow switches and pull stations. The IDP-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring OP-Monitor • Fully supervised Compatibility • Panel controlled status LED that flashes green in normal state The IDP-Monitor is compatible with the and is solid red in alarm following FACPs: • Attractive ivory cover plate • Rotary address switches for fast installation • IFP-2000 / RPS-2000 Intelligent Fire Panel • SEMS screws for easy wiring • IFP-2000ECS Emergency Communication • UL Listed System with Fire Panel • IFP-1000 / ECS Intelligent Fire Panel Installation • IFP-100/ ECS Intelligent Fire Panel The IDP-Monitor mounts directly into a 4" square electrical box. • IFP-50 Intelligent Fire Panel The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. P/N 350288 Rev J Copyright©2015 Honeywell International Inc. TO NEXT FROM PANEL OR DEVICE + ����� �Oa + PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT 71 MODULE CLOSURE DEVICES MAY BE USED.DO NOT MIX CONNECT MODULES TO LISTED COMPATIBLE FIREALARM INTIATING,SUPERVISORY,OR �O Q CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE e e ® H n N EOL T RESISTOR ELR-47K ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED INITIATING DEVICE CIRCUIT(IDC)-NFPASTYLE B POWER LIMITED:450NA MAX,@ 11 VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXT FROM PANEL OR DEVICE PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT MODULE CLOSURE DEVICES MAY BE USED.DO NOT MIX CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATING,SUPERVISORY,OR Q Qo CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. e Tn -) T EOL RESISTOR IS o o INTERNAL AT TERMINALS 8&9 ALL WIRING SHOWN IS SUPERVISEDAND POWER LIMITED INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications Environmental Physical Operating Temperature: 32°F — 120°F (0°C —49°C) Height: 4.5" (11.4 cm) Humidity: 10% —93% non-condensing Width: 4" (10.2 cm) Ordering Information Depth: 1.25" (3 cm) IDP-Monitor Monitoring Module Shipping Weight: 6.3 oz (196 g) Accessories Electrical SMB500 4" Square Surface Mount Electrical Box Operating Voltage: 15— 32 VDC SLC Standby and Alarm Current Draw: 350 pA End-of-Line Resistance: 47K 0 Max. IDC wiring resistance: 1,500 0 Max. IDC Voltage: 11 Volts Max. IDC Current: 450 pA SLC Loop Resistance: 40 Q max. SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to- date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are KNIGHT subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com SILENT Mounting Mounts directly to 4"square electrical boxes(see Figure 130 KNIGHT 2A).The box must have a minimum depth of 21/8". Surface mounted electrical boxes (SMB500)are available from Silent Knight. by Honeywell wiring NOTE: All wiring must conform to applicable local INSTALLATION AND MAINTENANCE codes,ordinances,and regulations.This module is in- INSTRUCTIONS tended for power limited wiring only. D P-M o n i to r-2 1. Install module wiring in accordance with the job draw- D u a I Monitor Module ings and appropriate wiring diagrams. 2. Set the address on the module per job drawings. Note: Monitor module L (using terminals 6 and 7)re- Specifications sponds at the address set on the code switches.Monitor Normal Operating Voltage: 15 to 32 VDC module H(using terminals 8 and 9)will automatically Maximum Current Draw: 5.7 mA(LED on) respond at the next higher address.For example,if the code switches are set to 76, module L will respond at Average Operating Current: 750pA(LED flashing) address 76 and module H will respond at address 77. EOL Resistance: 47K Ohms Use caution to avoid duplicate addressing of modules Max.IDC wiring resistance: 1,500 Ohms on the system. Temperature Range: 32°F to 120°F(0°C to 49°C) 3. Secure module to electrical box(supplied by installer), Humidity: 10%to 93%Non-condensing as shown in Figure 2A. Dimensions: 41/2'H x 4"W x 11/4"D (Mounts to a 4"square by 21/8"deep box.) Figure 1. Controls and Indicators: Accessories: SMB500 Electrical Box O O Before Installing a This information is included as a quick reference instal- ® 9 56789 ❑ lation guide. Refer to the control panel installation man- ® 8 2 1 Figure 2A. ual for detailed system information. If the modules will ® 7 , " 2 Module mounting: ® 6 456789 s be installed in an existing operational system,inform the 3 operator and local authority that the system will be tem- loop s oNLs° 4 no°aess porarily out of service.Disconnect power to the control � o ^ panel before installing the modules. (J/�) NOTICE:This manual should be left with the owner/ user of this equipment. ae CO21 a-01 General Description The Dual Monitor Module is intended for use in intel- ligent,two wire systems. It provides two independent I Figure 2B: 2-wire initiating device circuits (IDC), at two separate, consecutive addresses.It is capable of monitoring nor- o a mally open contact fire alarm and supervisory devices,or e a either normally open or normally closed security devices. The module has a single panel controlled red LED. Compatibility Requirements ® 0�0 To ensure proper operation,this module shall be con- a�a netted to a compatible Silent Knight system control panel m 0 (list available from Silent Knight). C0157-00 C0156-00 K200-13-00 1 156-2730-002 Figure 3.Typical 2-wire initiating circuit configuration, NFPA Style 13: TO NEXT � + PREVIOUS DEVICE FROM PANEL OR �� 00 TWO INITIATING DEVICE CIRCUITS(L&H), DEVICE + EACH POWER LIMITED TO 230µ4 @ 12VDC MAX. MONITOR MODULE CONNECT MODULES TO LISTED COMPATIBLE SILENT KNIGHT CONTROL PANELS ONLY 47 K EOL /) 0 o Q (� RESISTOR H lJ �J ELR-47K ° a ° H ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED ®a 35.7 ®s a a SIGNAL LINE CIRCUIT(SLC) 47 K EOL ❑e E� a 32 VDC MAX. RESISTOR L ELR-47K o��E SHIELDED-TWISTED PAIR Q 001 IS RECOMMENDED ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED.DO NOT MIX FIRE ALARM INITIATING,SUPERVISORY,OR SECURITY MONITOR A(TERMINALS 6&7)RESPONDS ATADDRESS DEVICES ON THE SAME INITIATING DEVICE CIRCUIT. SET ON CODE SWITCHES.MONITOR B(TERMINALS 8&9) C0809-01 RESPONDS AT NEXT HIGHER ADDRESS. INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. SILENT KNIGHT by Honeywell 7550 Meridian Circle Maple Grove,MN 55369-4927 763-493-6455; 800-328-0103 Fax: 763-493-6475 http://www.silentknight.com ©2006 Silent Knight 2/06 K200-13-00 2 156-2730-002 F a e t r n h y SILENT KNIGHT by Honeywell Addressable Relay Module Agency Listings IDP-Relay .,•T`"� MEA O° 386-02-E Vol II The IDP-Relay is an addressable relay module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The IDP-Relay contacts can be used for virtually any normally , open or normally closed application. Each IDP-Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the IDP-Relay, i the relay is triggered by the FACP. Features • Two sets of Form C contacts OP-Relay • Contacts are rated for a variety of amps (see Specifications) Compatibility • Panel controlled status LED that flashes green in normal The IDP-Relay is compatible with the state and is solid red in alarm following FACPs: • Relay programming is completely flexible—can be mapped . IFP-2000/ RPS-2000 Intelligent Fire Panel to zone conditions • Polling LED visible through the cover plate • IFP-2000ECS Emergency Communication System with Fire Panel • Attractive ivory cover plate • IFP-1000/ ECS Intelligent Fire Panel • Rotary address switches for fast installation • IFP-100 / ECS Intelligent Fire Panel • SEMS screws for easy wiring • IFP-50 Intelligent Fire Panel • UL Listed • IFP-25 Intelligent Fire Panel Relay Contact Ratings Current Load Installation RatingMax Voltage Description Application p The IDP-Relay mounts directly into a 4" 3 A 30 VDC Resistive Noncoded square electrical box. The box must have a minimum depth of 2-1/8". A surface mount 2 A 30 VDC Resistive Coded electrical box (System Sensor® PN SMB500) 0.7 A 70.7 VDC PF = 0.35 Noncoded is available from Silent Knight. 0.9 A 125 VAC Resistive Noncoded 0.46 A 30 VDC L/R = 20 ms Noncoded 0.5 A 125 VAC PF = 0.75 Noncoded 0.3 A 125 VAC PF = 0.35 Noncoded 2 A 25 VAC PF= 0.35 Noncoded P/N 350290 Rev J ©2015 Honeywell International Inc. CONNECT MODULES TO LISTED COMPATIBLE (-) CONTROL PANELS ONLY. (-) FROM PANEL TO NEXT OR PREVIOUS DEVICE (+) /� (+) DEVICE RELAY CONTROL (� MODULE If any wiring to Terminals 4-10 is Nonpower limited,The CB500 barrier O O is required.The C6500 includes a Nonpower limited label,which TOP o A o �O must be placed over the Power Tri O Limited terminal information on Relay Common 2 T10 Tt H the name plate label. Normally Closed 2 T9 T2 (+) Normally Open 2 1 Ta T3 Relay Common 1 1 T-n 7 9 7 9 T4 Unused Normally Closed 1 Ts 3Q T5 Normally Open 1 Z101s Z10 �O TENS 9 OPES � *NOTE:ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. Specifications Ordering Information Physical IDP-Relay Relay Module 4.675" H x 4.275" W x 1.4" D Shipping Weight: 6.3 oz (196 g) Accessories Environmental SMB500 4" Square Surface Mount Electrical Box Operating Temperature: 32°F — 120°F (0°C—49°C) CB500 Module Barrier Humidity: 10% — 93% non-condensing Electrical Operating Voltage: 15— 32 VDC End-of-Line Resistance: Not used SLC Standby &Alarm Current: .255mA max @ 24 VDC (one communication every 5 sec with LED enabled) SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or KNIGHT anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call Assembled in the by Honeywell 800-446-6444. www.farenhyt.com U.S.A. SYSTEM SENSOR° 5600 Series l Mechanical Heat Detectors 5601P System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, i and for non-life-safety installations where smoke detectors are inappropriate. cc,, 151°ii 5621 Features Multiple configurations.The 5600 series offers a full-line of • Multiple configurations for installations: configurations to accommodate a broad range of applications. Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations(Model 5601P) • Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, • Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5"and 4"Octagonal when used with a square to round plaster ring.The reversible —4-square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. • Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/ rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings @ FM UDC 0 AR i LISTED APPROVED S2101 3016008 CSG?o 7270-1653:0167 Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90oC),and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor.The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P,5603,5621,and 5623: 100°F(38°C) 5602,5604,5622,and 5624: 150OF(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623: 135°F(57°C) 5602,5604,5622,and 5624: 194OF(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 150F(8.3°C)rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact 6-125VAC/3A Ratings 6-28VDC/1 A 125VDC/0.3A 250VDC/0.1A Input Terminals 14-22 AWG e "yd O O O O O 5601 P 5602,5622 5603,5623 5604,5624 5621 Ordering Information MethodIdentification .. Model Circuit on Exterior Rating Activation Ceiling* 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) `NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Product specifications subject to change without notice.Visit systemsensorcom Phone:800 SENSOR2•Fax:630 377 6495 or current product information,including the latest version of this data sheet. SENSOR" www.systemsensor.com SPDS30001.7/13 Honeywell Farenhyt" Series THE POWER OF CONNECTED IDP-PULL-SA / IDP-PULL-DA Addressable Single Action and Dual Action Pull Stations The IDP-PULL-SA is a single action pull station requiring only one motion to activate the station.The IDP-PULL-DA is a dual action pull station requiring two motions to active the station.Both pull stations are designed to work with Honeywell Farenhyt series fire alarm control panels(FACPs). PULL DOWN INSTALLATION The IDP-PULL-SA and IDP-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm)or double gang or 4"(10.61 cm)square electrical box.You can also use the optional(System Sensor'PN BG-TR) trim ring if the station is being semi-flush mounted. IDP-PULL-SA COMPATIBILITY The IDP-PULL-SA and IDP-PULL-DA are compatible with the following . Honeywell Farenhyt Series FACPs: • IFP-2100/IFP-2100ECS/RFP-2100 • IFP-2000/IFP-2000ECS/RPS-2000 • • IFP-1000/IFP-1000ECS • IFP-300/IFP-300ECS • IFP-100/IFP-100ECS Honeywell • IFP-75 • IFP-50 IDP-PULL-DA FEATURES & BENEFITS • Installer can open • Key operated test and Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition y Guidelines(ADAAG) appears,clearly • Key matches • Braille text on station • Dual-color LED is compatible FACP controls and operating handle indicating the station visible through handle locks mechanisms has been pulled guidelines(Section • Rotary address of station blinks green Meets ADA 4.1.3[13]) switches for fast UL Listed,including to indicate normal UL 38,Standard of operation and remains requirement for 5 lbs ' Shell,door,and handle installation Manually Actuated maximum pull force to steady red in an alarm active molded from durable Signaling System condition LEXAN° • CSFM Listed • MEA Listed IDP-PULL-SA and IDP-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications,please visit ell www.farenhyt.com. L_........................................................................C lass.N..................................... W.N ._....................................................................._................................_.._........_-_.._.._._..., € Microsoft,Windows,and the Windows Logo are registered trademarks or trademarks of l l Microsoft Corporation. in : : . . . Honeywell'and System Sensor'are registered trademarks of and Farenhyt-is a Claaa AN4rmB:- - trademark of Honeywell Clara p Wl Z: International,Inc. Md.y IDP-P W ISA&IDP-Pull-DA Pull Slalio This document is not intended to be used for installation purposes.We SPECIFICATIONS* ORDERING INFORMATION tryto keep our product Physical:5.5"H x 4"D(14cm x 10.2cm) IDP-Pull-SA:Single Action Pull Station information up-to Shipping Weight:5.4oz IDP-Pull-DA:Dual Action Pull Station date and accurate.We HousingMaterial:LEXAN of carbonate resin cannot coverallor anticipate p Y applications or anticipate Bi-Colored LED: ACCESSORIES all requirements.All Blinking Green:Normal BG-TR:Optional trim ring. specifications are subject Steady Red:Alarm SB-I/O:Surface backbox,indoor/outdoor. to change without notice. Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to For Technical open(N/0)switch which closes upon activation of IDP-Pull-SA and IDP-Pull-DA Support,Please call the pull station 800-446-6444. ELECTRICAL RATINGS Operating Voltage:15—32VDC SLC Standby and Alarm Current:350µA Wire Gauge:Up to 12AWG(3.1 mmz) ENVIRONMENTAL Operating Temperature:32D-120°F(0°C—49DC) Humidity:10 to 93%non-condensing) For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security&Fire 12 Clintonville Road N o rthfo rd,CT 06472 Doc 350286 1 Rev H 1 11/17 Honeywell 800-328-0103 ©2017 Honeywell International Inc. SYSTEM SENSOR° Indoor Selectable- Output Strobes and 4*� Horn Strobes for Ceiling Applications f System Sensor L-Series audible visible notification r products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & F M X APPROVED LISTED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 AVDS868-02•12/01/2017•Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) 6.92"diam. 2.5' 6 diam. (175.77 mm) (64 mm (17 )� (173 mm) a•\a*r.rMr o TR O rn 0 o CDo 0 o 00 O O o Q o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box ® ( a 0 PA\NT OOO�o®mmm o0�0� O oOpem®0 00 • ® o�n — opu° / pp ppp °$o poo �000 • �°0000 0 � ovo A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM ©t to c System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR" Phone:800-SENSOR2•Fax:630-377-6495 or current product information,6,-02ng the latestversion ofthis data sheet. AVDS868-02•12/01/2017 SYSTEM SENSOR° Outdoor Selectable- Output Strobes and `'' .� L Horn Strobes for Ceiling Applications Spectrkerif Advance outdoor audible visible products SPECTRAfert are rich with features that cut installation times and a Iv v a Illiv c E maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof NEMA 4X, IP56 rated strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40OF to 151 OF. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor strobes and horn 135, 150, 177,and 185 strobes for ceiling applications include a variety of features that • Automatic selection of 12-or 24-volt operation at 15 and increase application flexibility and simplify installation. First,field- 15/75 candela selectable settings, including candela,automatic selection of 12-or • Rotary switch for horn tone and three volume selections 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151 OF Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Plastic and metal weatherproof back boxes come with () 3/4-inch top and bottom conduit entries and 3/4-inch knock-outs at the O 0: back.Three screw-in NPT plugs with O-ring gaskets for a watertight LISTED F M MEA 13011653:187(outdoor strobes) approved 7125-1653:188(hornstrobes, seal is included with each back box. 54011(chimes,horn strobes,horns) APPROVED chime strobes) 53593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) SpectrAlert Advance Outdoor Strobe,and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuitT"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four- wire products,the strobe shall be powered independently of the sounder.The horn strobe on a 2-wire model shall work on a non-coded power supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range with MDU Sync Module 8.5 to 17.5V(12 V nominal)or 16.5 to 33V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8-diameter x 2.5-high(173 mm diameter x 64 mm high) Strobe/Horn Strobe Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Strobe/Horn Strobe Dimensions with Back Box 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Ceiling-Mount Weatherproof Back Box Dimensions 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS11401 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw for 4-Wire Horn Strobes(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 StandardUL Max.Current Draw(mA RMS),2-Wire Horn Strobe, 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn Strobe Output candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe OutputPosition Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS11401 SpectrAlert Advance Diagrams 6.8" Dia. 0 2.5" � O 0 o Ceiling-Mount Horn Strobes Ceiling Plastic Weatherproof Back Box 0 0 Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) PC2RHK 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) PC2WHK 2-Wire,Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Ceiling Strobes SCRK Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SCWHK Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SCWK Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SCWHK Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Accessories SA-WBBC Red,Metal Weatherproof Back Box SA-WBBCW White,Metal Weatherproof Back Box MP120K Notes: "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing outdoor units,both the device and back box must be replaced. 1 SYSTEM ©2015 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensorcom SENSOR Phone:800-SENSOR2•Fax:630-377-6495 or current productinformation,AVDS1l1402 helatest version of this data sheet. AVDS11402•02/15 S YSTEM SENSOR° Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTRAlert SpectrAlertO Advance outdoor audible visible products CA 64 are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill () holes for screw-in mounting. Plastic and metal weatherproof back O boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED F M :0:MEA 7300 1653:187(outdoor strobes) approved 7125-1653:188(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket S4011(chimes,horn strobes,horns) APPROVED pp chime strobes) S3593(outdoor and alert strobes) 3N,'F7� MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuitT"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with •8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic OutputStrobe Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams 11 4.7" 11 4 2.5" 5.6" O 0 Wall-Mount Horn Strobes ® ® Wall Plastic Weatherproof Back Box UP Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description 1 Wall Horn Strobes P2RK`t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK"t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK`t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK•t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK't Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: Add '-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. f_ SYSTEM ©t to change System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Produc specifications subject02SysmSentnotice.Visit systemsensoccom SENSOR Phone:800-SENSOR2•Fax:630-377-6495 or current product information,ind1201 he latest version ofthis data sheet. AVDS01201•3/12 4�m '`NG � FIRE ALARM PERMIT APPLICATION t91� Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ❑✓ New Fire Alarm Fire Alarm Alteration/Addition 4011 172nd Street NE 31052100306700/-600/-500 Project Address: Parcel ID#: 1 FAC P 64,431 11,500 Number of Zones/Panels: Building Area(Sq Ft): Valuation: Owner: Market Street Development Phone Number: 206-658-5922 1602 Colby Avenue Everett WA 98201 Address: City: State: Zip Code: Contact Person:C amryn Olivarez Phone Number: 253-431-5860 Cell Phone: 253-833-1248 Email: camryno@firesystemswest.com 206 Frontage Rd N, Suite C Pacific WA 98047 Address: City: State: Zip Code: Contractor: Fire Systems West, Inc. Phone Number: 253-833-1248 206 Frontage Rd N, Suite C Pacific WA 98047 Address: City: State: Zip Code: FI RE S WI055LW 06/16/2023 Contractor's License Number: Expiration: Camryn Olivarez camryno@firesystemswest.com Contact Person: Email: Fire Systems West, Inc. 253-833-1248 Electrical Contractor: Phone Number: 206 Frontage Rd N, Suite C Pacific WA 98047 Address: City: State: Zip Code: Contractor's License Number:F I R E S WI055 LW Expiration:06/16/2023 hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws,rules and regulations of the State of Washington. 24:2�2tA_u 0&�t,2� 10/19/2021 Applicants Wature Date Camryn Olivarez Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6116LP GENERAL NOTES / SCOPE OF WORK Battery Calculations for Panel:Pi Circuit Calculations Panel:P1 Card:00 Circuit:NAC1 Circuit Calculations Panel:P1 Card:00 Circuit:SLC Symbol Legend Red No:IFP2100-1-10°,FACP,8 MO FLEXPUTGRCUITS,RED Circuit Na-NACi CircuR Name:SLC 1.SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND Pert Na. Description StandbyTotal Stand Alarm Total Alarm el-Typo Ngnn-en Inal vaMge:3o.3voe Amcereaa:a0000A OlrcutType:Bgnannglin IDF-SLo Inal VaW,:2o.3voe An-.:1.0000n CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING,WITHOUT 64 Panel Equipment Cable:-SOLJKTFPLRIMRLRED .14 Cable:l 6R SOL JKTFPLIMRLRED #16 II SYMBOL DESCRIPTION MANUFACTURER PART NUMBER QUANTITY caculatio„abeemOnR.ning-La ffi. Celepwm-eed-Running1calLangtn. APPROVAL,IS AT ELECTRICAL CONTRACTOR'S OWN RISK.. v IFR3100_MB 1 IFP210o INTELLIGENT MAN BOARD 33o.000anA 330.000OmA 415.000OnA 415.000OnN FA-E-8-1 INTEWNET 2.0 FIRE SUE.SCRIBER.-I-,]]94A.NOT,RID ENCLOSURE AEB CORP Tro7P49LLP51 1 Total Panel Slby 2300000m4 Total PanelAMrm -(I000NA Deeigt C,Nna'.A-lmnperetura:t67•F Ma.ead.gvalwgedrap:10% Deagn CMede:Ambienttemp.,ahve:18AF Maa.a-ngwltegedre IC% Penpbew Dcicn Device Pert No Appliance Desc Distance Current Vic a VoltageDro Device Part No Appliance Desc Distance Current VoltageVoltage Dr 2.SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY M FACP IFP.2100,FACP,8IICFLEXPUT CIRCUITS,RED FARENKYT IFP41DD 1 RA-+DOOR 1 REMOTE LCDANNUNCNTOR,RE.(Pw.er) 20.000OniR zD0000m4 zs.0°°OmA zs.0000mR IFP-21°0 Parel m- IFP-2100 Panel 2°.N USED FOR REFERENCE PURPOSES.ACTUAL WIRE AND DEVICE M-1oWR 1 REMOTE LOD ANNUNCNTOR,RED(Saea o.1 o0aM 0.1000mA C1-- D.1o0OnN M:1 IDP-0ULL-DA PULLSTATION,DOUBLEACTION,ADDRESSABLE 3-0C-TA30.188N (o.o003V) HORrLSTROBE,2 WIRE,STANDARD CD,RED,OUTDOOR SYSTEM SENSOR P2RK 1 IDP-PHOTO-W 8 SMOKE,PHOTO,ADD.WHITE,LOW PROFILE(Signalin9 line) 0.2000mA 1.6000m4 4.50 - a8D000mA 1 P2RK HORNJSTR06E,2WIRE.STANDARD CO.RED,OUTDOOR,110CD 35-0221.000OmA a°.i.e. (0.0138V) 8:1 IDP-PI-I SMOM.PHOTO,ADD,WHITE,LOW PROFILE 9-00.2000mA 20.- (0.000N) INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. R y�('° IDP-PULL-DA 1 PULL STATION,DOUBLE ACTION,ADDRESSABLE(Sgnaling line) 0.3500mh 03500mA C3500mA 0.9500mA 1 EOL4.7 EOL LM 10-0 O.000OmA 20.1864V (OV) M:2,3 IDPMGHITOR2 DUAL MONnOR MODULE T-0 0.7500TA 20.19s4V (0.0008V) ),WP HORWSTROBE,2WIRE,MC,RED,OUTDOOR,WEATHERPROOF SYSTEM SENSOR PC2RK 8 IDP-RELAY 6 RELAY MODULE,ADDRESSABLE(Si.-ma line) 0.2800mA 1.5800mA CO280mA )ASWmA 48'-0T21.ODDDmA M:4,51DRMONITOR 2 DUAL MONITNR MODULE 2-0075i 20.1983V (o.000+v) N IDPMONITOR2 8 DUAL MONTTOR MODULE(SIMMIIngline) 0- E.DO - 0.7 TA 6DOOOnA Cu W 221.° pnA M I- :6,7MONITOR2 DUAL,MOMIORMODULE 2•-0 0-TA2D.198N (ocooly) 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS � L0 H LSERIES2-WIRE,HORN STROBE,RED,CEILING SYSTEM SENSOR PC2RL g 5623 2 135•F(5A C)DUAL FIXED CIRCUIT TEMPERATURE(Initiating) 3.DD0- ODOOOm4 CoccomA DDOOOnA (Trial VD,o,P-D.OTN)Trial Vattege pop:0.0136V M:8,9I -MONITOR2 DUAL mA MONITOR MODULE Z-0 0.7500 2D.1961V (0.0oom MIRK 1 HORNSTROSE,2WIRESTANDARDCD,RED,OUTDOOR(NamoatiooI10CD860B o.DDDDTA OOOO)mA 221.000)mA 221.00OOTA KID,111DP-MONITOR2 DUAL MONINRMODULE 2-00.7500M 20.199V (000nv) LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE ®,a REMOTE LCDANNUNCIATOR.RED PARE.- RA-100011, 1 EOL4.7 ] EOL 4.7K(Net lflcalbn) O.0000TA ODOOONA 30000mA D.DIOOmA M:12,131DP-MONITOR2 DUAL MONITOR MODULE 1•-00.7500eA2D.197SV (O.00D+v) PERMITTED IN THE SAME RACEWAY. PC2RL 1 LSERIES2-WIRE,HORN STROBE,RED,CEILING(N.til-M,)150CD Bees O.DDd- O.00 - 229.0000- 229D°°OmA M:14 IDRR-RELAYMODULE,ADDRESSid- 19-00-TA 2D.1B76V (OnDosv) 1� W EOL 4.7K 11PC2RK 9 HORNSTROBE,2 WIRE,M-C,RED,OUTDOOR,WEATHERPROOF(Nafeeten)11SCD Sees O.Dod- 0.000Om4 229.0000-20n1.000dM MIS IDP-RELAY RELAYMOOULE,ADORESSA&E T-0 OZgO0mA 2D.1978V (M m EOL 6.7K FARENHtt EDL4] ] PaRL 4 LSERIE82-WIRE,HORN STROBE,RED,CEILING(Notinwnon)177OD Beds o.0000mA OOOOOmA 257.0000M 1028.0000mA Circuit Calculations Panel:P1 Card:00 Clrcult:NAC2 WAS IDP-RELAY RELAYMODULEADDRESSMLE 2-0 0.2600,RA 20.1978V (OV) ,my (rZ ama:NAC2 4.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST O$ SMOKE,PHOTO,ADD,WHITE,LOW PROFILE FARExHtt IOP4HIOT0-YI 8 P03RL 1 L4ERIE82-WIRE,HORN STROBE,RED,CEILING(xa4'aaeon)115CDsees O.000OmA OOOOOm4 184.0000m4 +64.000OnA Te..N t18 IP-MONI OR2 DUAl-M RUTCOR AOD,WHRE,LOW PROFILE R-D 0.20DDm42D.1B75V (DV) Bit ToleIPaNPIweI&Iby 28.6100m4TowPMpM1AMmt9]90.606OnR GrcudType:Nenwtion TeimlrelVdbge:20.N:DC Ampex0e:3000M M:17,1810P-MONITOR2 DUALMONf1ORMODULE 4'-00.]500m420.1875V (LL1 U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS APPLICABLE TO � o o a O 1%°F(a]•C)DUAL CIRCUIT FMEDTEMPERATURE SYSTEM SENSOR ass 2 Cable:141250LJKTFPLRIMRLREO eu - THE CITY STAN DAR DS. F Tbed Standby Amµ 259.6100,eA Teel Aenn Amps 4205.601 Cal.uletiombwed-Running TDteleryM. 8:5 IDP-PHOT W SMOM,PHOTO,ADD,WHITE,LOW PROFILE 13Y-0 0.2000,RA 20.19881 (0.0°1v) ©DA PULL STATION,DOUBLE ACTION,--a- FARE.- IDP4 I-1 1 Daegn Ore,,,.Ambient tempo-167'F Mix.opa Ang veep,Jrc 10% 8:6 CP-PHOTPW SMOM.PHOTO,ADD,WHITE,LOW PROFILE M'-00.20DmA 20186SV (0.0DD3v) Stendby ltm.:24 Hre 6.231AM1 Device Part No Appliance,Desc Dletance Current Voltage Voltage 67 IDP-PHOT6W SMOKE,PHOTO,ADD,WHITE,LOW PROFILE sr-0°.2000TA 2D.19SEV (D.aaD1v) 5.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, RELAYMODULEADDRES9ABLE FARENHYT IDPRELAV 8 Alarm lima:SMln 0.35Ab IFF-3100 Pais 20.N - A CV eanery requlremml: san. 1 PC2RL LSERIES2-WIRE,HORN STROBE,RED,CEILING,150CD 2SA0229.0000NA20.1808V (o 0394y) 88 IDP-0HOTO-W SMOM,PHOTO,ADD,WHITE,LOW PROFILE 1774 o.=TA 20.19e3v (o.0003W FACTO RY AVAI LABILITY,LITY,ETC.FIRE SYSTEMS WEST RESERVES THE RIGHT /� 0 O¢ DUAL MoNffOR MODULE FARENHtt IOPJAONITOR2 8 Ca eoeaBon Fads.-S+andty.1.2 Alerm:l2 Requiremea vnlM1 compenaNion: 7.897AM1 1 EOL4.7 EOL4.7K s'-0 D.DDCCTA 2D.1806V (O✓) - TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH r/ z MI. IDP-RELAY RELAYMODULE,ADDRESSABIE Se.G-TA 2C.1- (0.000T0 33'-0228.WOGnA 11120 IDP-REU1Y RE-..DULEA00HEs6A&E 2-00.3sgonA30.19r7v (oh EQUIPMENT OF EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. pb., . Thl Cunea:228.000Om4 M:21 IDPRELAY REIAYMODUIE,AOIXiE33ABlE Y-00.-20.197TV (DV) 0) 00 C1 2D.-SMOM.PHOTO,ADD,WHITE,S vD,Pe Total rcee:0.19%)Total Voltage D.,0- :3 IDPFHOTO-W LOW PROFILE 3-0 0.2000m4 (OV) Circuit Calculations Panel:P7 Card:00 Circuit:NAC4 ( M:Yl,23R -MONITOR2 DUAL MONITOR MOM. 4•-00.75 -2D.1976v (o✓) 6.PARALLEL BRANCHING(T-TAPPING)OF WIRE TOALL NOTIFICATION C m Circuit Calculations Panel:P1 Cab:00 Circuk:NAC3 Ci-Nema:NAG 3 ro Gmuit Name:NAC3 GrcuXType:NaMralon TenNnel Vultape:20.N:OC Amperepe:3.0000A - APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. Q m w� Circuit Type:Ncdf Nion T inel Valege'.20.N'.DC Ampere:3.0000A 34 IDP-0HOl'0.W SMOM PHOTO,ADD,WHITE,LOW PROFILE 5T-00.--2D.1983V (O.0wiv) Caxe:-SOLJKTFPLRIMRLRED #14 4 Calwlatianama -Rvnnieo-1-... Circuit Calculations Panel:P1 Card:00 Circuit:SBUS 5ro•-0s.s'oomA Tatalcarea:9.51DDmA 7.FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL •� o m N U C-letens based ee R...Ine Total Lengh, Deeign Caere:Amxeetemperabr 1-F Wv.apereegeA-dr:l0% Ce-Neme:SBUS (Total VDrop PercanL002°b)Teal VOlbee Dmp:O.000N C9 D" 41 Oeagn Creaie'.Pmbiea temperature:167•F Mme.opeR.t, b,;cdr 1D% Device Part No Appliance Deso, Distance Current VOltag¢Voltage Drop GrwX Type:Pww5BU5 RSJB5 rmnlnel v.Ira2D.-Oc Amcera:l.000OA PANELAND WIRELESS COMMUNICATOR(AES). 3 Device Part NO Appliance Desc Distance Current Voltage Voltage Drop IFR2100 Re. 20.N -182SOLJKTFPLR1MRLRED #18 IFP-210° Panel 20.N 1 PC-LSERIES 2ANIRE,HORN STROBE,RED,CEILING,115CD 12Y-0184.°000m419.B89v (CnnT .--an Ranniro Tmal Langtn. SYSTEM OUTPUTS 1 PC2RK HORWSTROBE,2 WIRE,M-G,RED,OUTDOOR,WEATHERPROOF,115CD 61'-0229D000�A19.942N (0.2573V) 2 PO-LSERIE82-WIRE,HORN 8TROSE,RED,CEILING,IT/CD 83-0257.000OmA18.]70N (O.WB4V) DeegnCr#eria:AmbierdtemlRrebae:lBAF Max.apeceingwltged.,10% B.FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS,MONITOR 3 PC- HORWSTROBE,2WIRE,MC,RED,OUT000R,WEATHERPROOF,115CD 80-022B.000OnA19.T28N (0.08001n 2 EOL4.7 EOL4.7K 5-0 0.00-19.7-V ICY) Device Fart Pw.I ApplianceDe9C Distance CU-nt V°ZON Volta eDro Required Fire Safety Control MODULES,AND RELAY MODULES FOR ELEVATOR RECALL. v 3 EOL4.7 EOL4.7K 5-0 O.000OmA19.726N (OV) 187'402D000O-ID' (O.Wa1V) Notification �Iaw curreM:441.olxxanA OmA 18-20DDO 9.FIRE SYSTEMS WEST WILL INSTALL DUAL CIRCUIT HEAT DETECTORS -0687.000PeA aryuapPereadz.,3%)Teal ftes.Drep:0.4296V realCune MCDDm4 Control Unit Annunciation FOR ELEVATOR SHUNTTRIP.Tabl Current 68].000OmA (Taal VDrcp Pace:-%)Total WMege Dmp:0.4]38V (<I wrap Pe.-C-)loel Volepe Dr:0.0581V } m 10.FIRE SYSTEMS WEST WILL INSTALL NEW MONITOR MODULES TO Circuit Calculations Panel:Pil Card:00 Circuit:NAC6 MONITOR THE SPRINKLER RISER. ci-N.-NAC6 Circuit Calculations Panel:Pi Card:00 Circuk:SBUS2 CITCUIt Calculations; Panel:P1 Card:00 Circuit:NACS / LU Grail Ty Aefire- Terminal V.eaS.:20 cc Ampalg.:9.000OA Circuit Nam.:asU52 F- CFctle Narne:NACS Cable'.14QSOLJKTFPLRIMRLRED #14 Clrcult Type:SetlMSBUs RS-4B5 Termlml-.:55vDC Ampere:1.0000A Q 11.FIRE SYSTEMS WEST WILL INSTALL NEW WEATHERPROOF Grcult Type:Ngtl Cable Tmiital VallR1MRLRED Ampetye:3.000OA -uleionebasedae Running Taal LaepM. Cable:1612STRJKT1MRLGRY #IS C Q (� Cabe:1II280L JKT FPLR IM RL RED 914 IJe.ign caena:Ambiem tanpaamre:lerF Mar.gp ReR,Y.Iegedr:l0% c.mvlmaa b..ea an RvnniM ILeryM. O `�. NOTIFICATION DEVICES THROUGHOUTTHE PARKING GARAGES. Camuleiombeee RunningT.wLerMw. Creata:AmbNa4bmperature:167°F MNI. ReJngveft",deo:1O% L 'a�v m "`• Device Part No fence Desc Digtence Current Vo Volta e D °ea19n Oagn Criwla:PmaeM empaatuµ:lBYF Mu ap.rMgg wlt+0adroP:10% IFR2100 Panel 20.N D.A..IftrtNol ADDliance Desc Distance Current Volta a I Voltage Dro Device Part No Appliance Desc Distance Current Volta a Voltage 1 PC2RK HORNSTROBE,2 WIRE,MC,RED,OUTDOOR,WEATHERPROOF,115CD 177•4 228.000OmA 1B.1534V (0.7468V) IFP-2100 Penal Ay tp "' Q 12.FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES FOR IF0.2100 Panel 20N 2 PC2RK HORNIBTROSE,2 WIRE,MC,RED,O-OOR,WEATHERPROOF,115CD ".422a0000TA19.253N (0.18BN) RA-1000R REMOTELCDANNUNCATOR,REO 18T-00.1000mA ` a ` THE SHELL LAYOUT. 1 HOXR. HO.WBT1eo8E 3 WIRE Mc REO OUTDOOR WEATHERPROOF MD 81w u9.D00anA t9.aamv (0.7e85v) 3 PC- HORWSTROBE,2 WIRE,MC,RED,OUIDODR.WEATHERPROOF,115C0 717-0 229000DM 19.156N (0.09%V) mjO i'a (Q �/,�• \2 PC2RK HORWSTROBE,2WIRE,MC,RED,OUTDOOR,WEATHERPROOF,115CD 171'-022B.000OnA 1B.2368V (0.1997V) 3 EOL4.7 EOL 4.]K a-0 OOOOOmA 3 PC2RK HORWSTROBE,2 WIRE,M-C,RED,OUTDOOR,WEATHERPROOF,115C0 JII-0 229.000GnR 19.1386V (0.0984V) 324'-0 8870GX3M �f V jZ 3 EOL4.] EOL 4.7K 5'-0 O.000OmA 19.1984V (OV) Taal Current: 3zr-06W.WWtnA (ra.Iwrep Pacea:s.n%)Taw Wllepe Drcp:l.a4nry \C �W AC \ \ Trial Current:BB].000OmA \ ` m (T�talVDrcp Percen1:5.26%)Tow WMeg:Drcp:1.O616V cm \ � ti � o oa •°�`�'o����• CODE COMPLIANCE Circuit Calculations Panel:P1 Card:00 Circuk:NAC7 OCC.TYPE/LOAD: B GrcMNam:NAG] Cm\9CJ Grclt Type:Natlna TNIVe OC ma3.0000A m Q ' AREA: 64,431 SF O CaNe 12LJKPRMRILREO14 Q pm •y � iy Gmuetione based on Running-Lagb. FO \� FO \� FO \� ` 1�O C� O O� Deegn Cneda:Amxe-perature:187•F M,v o-ftvc4eµdr4p:+0% •� •� •� V Jm J \ •#Ar •Ay Lt..l �QF a F a F a J O O Device Part No Appliance Desc Distance CUITent Von Dro CONSTRUCTION: II-B SPRINKLERED((,m y (( �m\�\� of IF1%2100 Pere 20.N 1 PC2RL LSERIES2-WIRE,HORN STROBE,RED,CEILING,1]]CD 55'-0257.WDGiA 19.9398V (0.2SOCN ` ` ` '•�' ay ay 2 PC2RL --SERIES 2-WIRE,HORN STROBE,RED,CEILING,177CD 128'-025].000Om419.5EN (OAWv) ••lr� •a.r� 400 `ti�r `� •� •V� •hr� W APPLICABLE CODES: ARLINGTON MUNICIPAL CODES o m m m m m m 1a m w w m Z 3 PC2RL LSERIES2-WIRE,HORN STROBE,RED,CEILING,177CD 129-0257D000nW19.3321V (C2036V) J J J J J Q C C J 2015 INTERNATIONAL BUILDING CODE 3 EOL4.7 EOL4.7K T-0 O.ODOOm419.=Iv (OV) 319-0 771.000OmA 4 Qt Teal caeea:771.DDDDmA `1 U Q• Q• Q• Q• Q' Q' Q• Q• 2015 INTERNATIONAL FIRE CODE (IMaYoq Peraee:430%)TaalvonaeeDrop:o.ae79V SYSTEM INPUTS A B C D E F G H I J K L M N 2017 NATIONAL ELECTRICAL CODE 2016 NATIONAL FIRE ALARM AND 1 Fire Alarm AC Power Failure • • • 1 SIGNALING CODE 2 Fire Alarm System Low Battery • • 0 2 m 8 3 Open Circuit • • • 3 4 Ground Fault • • • 4 A 14/2FPLP B 1612 FPLP H g 5 Notification Appliance Circuit Short • • • 5 EX EXISTING LOCATION o 6 Manual Fire Alarm Boxes • • • • • • 6 WP WEATHERPROOF DEVICE a N NEW DEVICE 14/2 7 Smoke Detectors • • • • • • 7 R RELOCATE EOLf2 177CD 177CD 177CD 8 Heat Detectors • • • • • • 8 STROBE COVERAGE Fr CL SHALL BE DEFINED L 10 FT.CLG.HT. 20 Did CLG.HT. 30 Fr.CLG.HT. H H H 15cd=2a)a0? aocd=20zva 75cd=3M 9 Elevator Smoke Detector-1st FI. • • • • • • • 9 aom=�os�a 75cd=3o�x3a s5od=sa)rao� oo 10ssm=SakXso �0�4�ox45°a iiasm=SakX5a�� 10 Elevator Smoke Detector-2nd FI. • • • • • • • 2P 11 Elevator Smoke Detector-Parking Garage • • • • • • • 11 14/2 12 Waterflow • • • • • • 12 w WP 177CD WP 177CD WP 177CD w EOL 4.7Kf2 13 Sprinkler Control Valve • • • 13 Drawing revie:ved b`: Z H H H A B C DIE F G H I J K L M N o 0 NIattCazlman LuLu LLI OPERATIONAL MATRIX \ICET Certification\o. 146053 14/2 Fire Alarm Systems-Level III E0L 4.7K 0 WP 177CD WP 177CD WP 177CD Certification Expires: \ovember O1, '0�3 z H H H vy ro ti 11 .F E-mail: mattcgfires}7stemswest.com Phone:253-951-6005 N 14/2 Lu 0 o LL EOL 4.7K 177CD 115CD o H H s S WORK AREA z x P °cam C.3 h 5 5ti �ti 14/2 EOL 4°7K Q WP 115CD WP 115CD WP 116CD H H H S S S S I ° E ARM RM RM Ai F 8 CG CG G I �� � • y" y" z 3 14/2 AES �• ®` E !L �wM L EOL 4.7K 0 150CD DA of o=�� s }�. H P S AIM AIM AIM NM AIM AIM RM RM RM S M 1 m n ^2 /�2 pD2 ^g�2 ^Iy2 A^d, A^(n A^CG tT7 A�2 • <t� ^ d O � ffO f, b' y. A of c3 c3 c2 ° y� m a T�� 5� y� cyv V 6 0 5 F'i 13 m `m 14/2 IFP-2100 LCD �,v yv yv O 8 W EOL 4.7K 0 WP 110CD ,C� ----- Jy O oz C) Z r Ca A 5 r�V 0._9 w o� 20AMP Y , O M p E Z € O Q N 20 AMP DEDICATED CIRCUIT Area 0 i� VICINITY LL v m . . . . . . . . . . . . . . . . . . . ....♦ . . . . . . . . . ♦r A -o ¢ 0 WIRING DIAGRAM „ a SCALE:N.T.S. ILL, 4 w a w a - GENERAL NOTES / SCOPE OF WORK 1.SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MAN UFACTU RE AND CODE REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING,WITHOUT APPROVAL,IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2.SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY M USED FOR REFERENCE PURPOSES.ACTUAL WIREAND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. y 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. F� x 4.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS APPLICABLE TO o o a THE CITY STANDARIDS. I 5.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAI LABILITY,ETC.FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH y • D EQUIPMENT OF EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. I :--i n 6.PARALLEL BRANCHING(T-TAPPING)OF WIRE TOALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. Q m w ♦ Z 7.FIRE SYSTEMS WEST WILL INSTALL NEW FIRE ALARM CONTROL N w o I m PANELAND WIRELESS COMMUNICATOR(AES). y 3 D B.FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS,MONITOR Y • MODULES,AND RELAY MODULES FOR ELEVATOR RECALL. v I 9.FIRE SYSTEMS WEST WILL INSTALL DUAL CIRCUIT HEAT DETECTORS FOR ELEVATOR SHUNTTRIP. r • m 10.FIRE SYSTEMS WEST WILL INSTALL NEW MONITOR MODULES TO MONITOR THE SPRINKLER RISER. w 11.FIRE SYSTEMS WEST WILL INSTALL NEW WEATHERPROOF o NOTIFICATION DEVICES THROUGHOUTTHE PARKING GARAGES. 12.FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES FOR NACS THE SHELL LAYOUT. EOL 4.71(0 H NACS•3 H NAC52 TO FACP WP"'CID VYP 115CD WP 715CD CODE COMPLIANCE OCC.TYPE/LOAD: B AREA: 64,431 SF O E Ln CONSTRUCTION: II-B SPRINKLERED Lu APPLICABLE CODES: ARLINGTON MUNICIPAL CODES o 2015 INTERNATIONAL BUILDING CODE z 2015 INTERNATIONAL FIRE CODE Y o 2017 NATIONAL ELECTRICAL CODE = 3: 2016 NATIONAL FIRE ALARM AND WEST PARKING SIGNALING CODE c 08 ❑ I] A 14/2 FPLP B 1612 FPLP Ho EX EXISTING LOCATION o a WP WEATHERPROOF DEVICE Q N NEW DEVICE R RELOCATE NAC5 STROBE COVERAGE AREA SHALL BE DEFINED AS EOL 4.7K 0 H NACS•9 H NAC5.2 NAC5.1 TO FACP 10 FT.CLG.HT. 20 Ff.CLG.HT. 30 Ff.CLG.HT. 15 cd=20X20' 30 cd=20'z20' 75 cd=20WO WP 115CID WP 115CD H WP 115CD X 30 cd=305C3D' 75 cd=30'X30' 95 cd=30'X30' ELEV.#1 95 od 5(lx50a' 11 d 45o15a 1 55 cd 50xx50' U) z o cn o w o VESTIBULE LCD a FAA m O STAIR 1 Z = Lu I r C7 >N Z oLL • fll Lu m 'w I D WORK AREA z x SMOKEY POINT MOB FIRST FLOOR-WEST I ♦ 8 6' 7 d' 6 12' 20 SCALE: 1/9'=1'-0" EL o m I z z Z^ S mo A ¢ W ♦ Lu d m � O w U W w O O �x m U o E!!�c 2E (n N ¢ O N VICINITY LL . m s 0 „ SCALE:N.T.S. w 4bi w a - GENERAL NOTES / SCOPE OF WORK 1.SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MAN UFACTU RE AND CODE REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING,WITHOUT APPROVAL,IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2.SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY M USED FOR REFERENCE PURPOSES.ACTUAL WIREAND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. y 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. F� x 4.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS APPLICABLE TO o o a THE CITY STANDARIDS. V) 5.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAI LABILITY,ETC.FIRE SYSTEMS WEST RESERVES THE RIGHT I TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH 4 z o EQUIPMENT OF EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. �M) o ♦ D I 6.PARALLEL BRANCHING(T-TAPPING)OF WIRE TOALL NOTIFICATION B� APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. Q m w n = 7.FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL •� N w o C r PANELAND WIRELESS COMMUNICATOR(AES). g ♦ Z m B.FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS,MONITOR D MODULES,AND RELAY MODULES FOR ELEVATOR RECALL. v ♦ 9.FIRE SYSTEMS WEST WILL INSTALL DUAL CIRCUIT HEAT DETECTORS FOR ELEVATOR SHUNTTRIP. } SLC6:4 m MAIN ELECTRICA s 10.FIRE SYSTEMS WEST WILL INSTALL NEW MONITOR MODULES TO STAIR 2 MONITOR THE SPRINKLER RISER. • w 11.FIRE SYSTEMS WEST WILL INSTALL NEW WEATHERPROOF o ELECTRICAL ELEV.#3 NOTIFICATION DEVICES THROUGHOUTTHE PARKING GARAGES. s yo s 12.FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES FOR yxGG� THE SHELL LAYOUT. NAMEOL 4.7K 0 �SLC63 NACl*lTO FACP NAC N7 2 S WP 115CD EOL 4.7K0 a.j Z NACM CODE COMPLIANCE 11" WP 116CD LCM: 23 H 50Cp OCC.TYPE/LOAD: B ELEVATOR MACH. RM. cn ® — ® AREA: 64,431 SF O L NAC4 CONSTRUCTION: II-B SPRINKLERED Lu EO )i L 4.7K st TO FACP SLC-M:2,3 FACP P LC�I11:1 SLC-M:4,5 AEs DA APPLICABLE CODES: ARLINGTON MUNICIPAL CODES b SLC-M:5,7 2015 INTERNATIONAL BUILDING CODE z H NAC442 SLC•M:S,9 s NAC1 2015 INTERNATIONAL FIRE CODE 177CD 0 a SLC•M:10,11 q,„ SLC6:1 EOL 4.7K❑ `1 V nh.� _ Aj.J+• SLC•MA2,13 ,,, 'o, 2017 NATIONAL ELECTRICAL CODE '�G'�G`'�o c1.1 2016 NATIONAL FIRE ALARM AND O WP 110CD SIGNALING CODE ssLc6:2 FIRE SPRINKLER m 8 OFFICE EAST PARKING a 1 ZN41 SLCiA:17,10 A 14/2 FPLP B 1612 FPLP H o EX EXISTING LOCATION o a WP WEATHERPROOF DEVICE N NEW DEVICE sLc6:5 ELEVATOR MACH. R . R RELOCATE \ / STROBE COVERAGE AREA SHALL BE DEFINED AS \ / 10 FT.CLG.HT. 20 Ff.CLG.HT. 30 Ff.CLG.HT. 15 cd=20x20' 30 cd=20'x20 76 cd 20WO \ / 30 cd=30'x3D' 75 cd=30'X30 95 od=30x30' \ / 75 cd=40x40' 95 cd=40'x40' 110 cd=40x4a H NP'C5.1 TO FACP \ / 95 cd=50x50' 110 cd=50x50' 115 cd=50'x50' WP 115CD X ELEV.#1 ELEV.#2 // \\ H NAC3.2 H NACM TO FACP / \ \ WP C. PlP 115CD w Z w O H NAC4.1 OLL 115CD of m TO FACP 'CID O Z FAA � OfNm � z `n o LL w V ♦ m WORK AREA V Z x ID SMOKEY POINT MOB FIRST FLOOR-EAST - s a g z o• v . m Z ¢ L SCALE: 1/8"=1'-0" EL �w z�m� — ,� � o=mom a I w d o w O m v H Frp O ..pZN V D ¢� < Z Lu 2�9 O .2 � W � o V w O o Esc 2E O Q N VICINITY LL SCALE:N.T.S. w 4 bi w a w w a - GENERAL NOTES / SCOPE OF WORK 1.SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MAN UFACTU RE AND CODE REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING,WITHOUT APPROVAL,IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2.SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY M USED FOR REFERENCE PURPOSES.ACTUAL WIREAND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. y 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. F� x 4.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS APPLICABLE TO o o a THE CITY STANDARIDS. V) 5.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, I FACTORY AVAI LABILITY,ETC.FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH 4 z " o EQUIPMENT OF EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. M) o ob • °e�cl 6.PARALLEL BRANCHING(T-TAPPING)OF WIRE TOALL NOTIFICATION I n APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. Q m w 2 � r 7.FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL w • Z PANELAND WIRELESS COMMUNICATOR(AES). y�iTi� 3 m D B.FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS,MONITOR Y MODULES,AND RELAY MODULES FOR ELEVATOR RECALL. v ♦ 9.FIRE SYSTEMS WEST WILL INSTALL DUAL CIRCUIT HEAT DETECTORS I FOR ELEVATOR SHUNTTRIP. } m 10.FIRE SYSTEMS WEST WILL INSTALL NEW MONITOR MODULES TO MONITOR THE SPRINKLER RISER. w F- 11.FIRE SYSTEMS WEST WILL INSTALL NEW WEATHERPROOF o NOTIFICATION DEVICES THROUGHOUTTHE PARKING GARAGES. I♦ 12.FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES FOR THE SHELL LAYOUT. • I CODE COMPLIANCE OCC.TYPE/LOAD: B I AREA: 64,431 SF O Ln w • CONSTRUCTION: II-B SPRINKLERED fl� I APPLICABLE CODES: ARLINGTON MUNICIPAL CODES o CT 2015 INTERNATIONAL BUILDING CODE z EOL4t7K0 NAC7.3 NA07•2 • 2015 INTERNATIONAL FIRE CODE Y V " lnco " lnco 2017 NATIONAL ELECTRICAL CODE 2016 NATIONAL FIRE ALARM AND SIGNALING CODE • m 8 I A 14/2 FPLP B 16/2 FPLP Ho ♦ EX EXISTING LOCATION o a I WP WEATHERPROOF DEVICE N NEW DEVICE R RELOCATE SLC-S:6 STROBE COVERAGE AREA SHALL BE DEFINED AS ♦ �� �� 10 FT.CLG.HT. 20 Ff.CLG.HT. 30 Ff.CLG.HT. I OPEN TO\ / 5cd=2a¢a' 3ocd=za'xza 75cd od 30x2a 95 =3 30 cd=305C3D' 75 cd=30'X30' 0'X30' BELOW 75cd=wxaa 95 m=aaXw' 11acd=wxaa ELEV.#1 ELEV.#2 95 cd=5ax50' 110 cd=5ox50' 115 c d=5ax50' I i w z w O ♦ sLca:7 Ln o I > o Lu w • o z STAIR 1 ry ♦ Lu N m 0 z r w " oLL z o � • D WORK AREA z x I SMOKEY POINT MOB SECOND FLOOR-WEST I 8 t a 2' 4' 6 12' la SCALE: 1/8"=1'-0" I UN3 m E O_ w_ ♦ o Lu d o _ F m � O v O ..mo?N o o �c) z Lu =a¢ W w O O �x m u o Esc 2E (n N�¢ O Q N VICINITY LL SCALE:N.T.S. w 4 bi w w a w a - GENERAL NOTES / SCOPE OF WORK 1.SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MAN UFACTU RE AND CODE REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING,WITHOUT APPROVAL,IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2.SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY M USED FOR REFERENCE PURPOSES.ACTUAL VVIREAND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. y 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. F� x 4.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS APPLICABLE TO o o a THE CITY STANDARIDS. V) 5.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAI LABILITY,ETC.FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH 4 z " o EQUIPMENT OF EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. �M) e'd o I 6.PARALLEL BRANCHING(T-TAPPING)OF WIRE TOALL NOTIFICATION ♦ D APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. Q m w I N 7.FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL �� N w C = PANELAND WIRELESS COMMUNICATOR(AES). �iTi� y 3 r • z B.FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS,MONITOR Y Im MODULES,AND RELAY MODULES FOR ELEVATOR RECALL. v D 9.FIRE SYSTEMS WEST WILL INSTALL DUAL CIRCUIT HEAT DETECTORS • FOR ELEVATOR SHUNTTRIP. r I m 11 10.FIRE SYSTEMS WEST WILL INSTALL NEW MONITOR MODULES TO S MONITOR THE SPRINKLER RISER. ♦ BLcs:6 Lu STAIR 2 11.FIRE SYSTEMS WEST WILL INSTALL NEW WEATHERPROOF o NOTIFICATION DEVICES THROUGHOUTTHE PARKING GARAGES. ELEV.#3 12.FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES FOR • THE SHELL LAYOUT. ICODE COMPLIANCE IOCC.TYPE/LOAD: B ♦ AREA: 64,431 SF O Ln I CONSTRUCTION Lu: II-B SPRINKLERED � ♦ APPLICABLE CODES: ARLINGTON MUNICIPAL CODES o I 2015 INTERNATIONAL BUILDING CODE z 2015 INTERNATIONAL FIRE CODE 2017 NATIONAL ELECTRICAL CODE NAC72 ♦ y-.�NAC7.1 2016 NATIONAL FIRE ALARM AND " 177co 177C' TO FACP SIGNALING CODE m 8 ♦ A 14/2 FPLP B 16/2 FPLP H I EX EXISTING LOCATION o a WP WEATHERPROOF DEVICE ♦ N NEW DEVICE I R RELOCATE S STROBE COVERAGE AREA SHALL BE DEFINED AS \ / 10 FT.CLG.HT. 20 Ff.CLG.HT. 30 Ff.CLG.HT. \ / SLC-6:6 15 cd=20x20' 30 cd=20'x20 75 cd=20WO \ / 75 cd=40''xx40' 95 cd=40'x40' 0 cd 340k40' ♦ \ / 95 cd=50x50' 110 cd=50k50' 115 cd=5(Yx50' I OPEN TO\ BELOW ELEV.#1 ELEV.#2 / \ w u) -> I O of cn o S w o ♦ SLC-S:7 I N o z z ¢_ n Lu oW I Lu V WORK AREA x z z • m ID ISMOKEY POINT MOB SECOND FLOOR- EAST c 8 ♦ O 2' 4 6 iT 20' U ¢ s SCALE: 1/8"=1'-0" A zg ur3 ¢V¢�� I ® IL- K Wo Z a m g a v I W cs m c Lu w LL 0 m a Frp O ..pZN V W W O O �x m U o Esc Z (no N�¢ O N VICINITY g LL . m A o RSCALE N.T.S. w 4 w a w a - Raelynn Jones From: Camryn Olivarez <1998camryn@gmail.com> Sent: Monday, February 14, 2022 10:24 AM To: Raelynn Jones Subject: Permit Cancellation Request Attachments: Smokey Point - Fire Alarm Permit.pdf [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Good morning, I need to cancel/close out a fire alarm permit. We are no longer doing the work associated with permit#4199. Attached is the permit in case you need it. Does Arlington issue refunds for permit cancellations? Additionally, I have tried emailing the city of arlington through my work email (camryno@firesystemswest.com) but it appears that I have been blocked? Is there any way you can remove me from the blocked list? Camryn Olivarez 253-431-5860 1 I CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 4011 172ND ST NE Permit#:4199 Parcel#: 31052100306500 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:New Fire Alarm Valuation: 11500.00 OWNER APPLICANT CONTRACTOR MARKDEV SMOKEY POINT LLC Fire Systems West,Inc. Fire Systems West 105 TALLAPOOSA ST STE 307 206 Frontage Rd.N. Ste.C 206 Frontage Rd.N.Ste C MONTEGOMERY,AL 36104 Pacific,WA 98047 Pacific,WA 98047 253-833-1248 206-833-1248 LIC:FTRESWI055LW EXP:06/16/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I O/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 2,1 ,� �� r i a Prid Name J Date Released By Dale CONDITIONS 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET II certification upon request.2.Battery load test required,switch distributed power module to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power.3.Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the City of Arlington stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2)5.The record of completion form shall be submitted prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/16/2021 FACP/Transmitter $200.00 11/16/2021 Fire Alarm System Permit $350.00 11/16/2021 Processing/Technology Fee $25.00 11/16/2021 Fire System Plan Review $203.35 Total Due: $778.35 Total Payment: $778.35 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon " CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 4011 172ND ST NE Permit#: 4199 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052100306500 DATE OF ISSUANCE. Scope of Work: New Fire Alarm Valuation: 11500.00 OWNER APPLICANT CONTRACTOR MARKDEV SMOKEY POINT LLC Fire Systems West,Inc. Fire Systems West 105 TALLAPOOSA ST STE 307 206 Frontage Rd.N. Ste.C 206 Frontage Rd.N. Ste C MONTEGOMERY,AL 36104 Pacific,WA 98047 Pacific,WA 98047 253-833-1248 206-833-1248 LTC:FIRESWI055LW EXP:06/16/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law, or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Datc CONDITIONS 1. Permit and set of approved plan: emain on site during installation. Installers sl. resent NICET II certification upon request.2. Battery load test required, switch distributed power module to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the City of Arlington stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2)5.The record of completion torm shall be submitted prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/16/2021 FACP/Transmitter $200.00 11/16/2021 Fire Alarm System Permit $350.00 11/16/2021 Processing/Technology Fee $25.00 11/16/2021 Fire System Plan Review $203.35 Total Due: $778.35 Total Payment: $778.35 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 4199 Permit Date: 10/20/21 Permit Type: Project Name: Smokey Point Medical Office Company/Applicant Name: Fire Systems West, Inc. Company/Applicant Address: 206 Frontage Rd. N. Ste. C City, State, Zip: Pacific, WA 98047 Contact: Camryn Olivarez Phone: 253-833-1248 Email: camryno@firesystemswest.com Permit Type: Fire Alarm Valuation: 11500.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: New Fire Alarm MIC/Opportunity Zone: Permit Issued: Permit Expires: 04/18/2022 DNU: Status: IN PROCESS Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning BSP#418 REC AFN MARKDEV 910 31052100306500 4011 172ND ST NE 201808215006&AMD BSP SMOKEY POINT UNDEVELOPED REC AFN 201811065001 LLC (VACANT)LAND Contractors Contractor Primary Contact Phone Address Contractor Type License License# Rd. Fire Systems West Matt Carlman 206-833-1248 206 FrontageCONTRACTOR Labor andFIRESWIOSSLW N.Ste C Industries Plan Reviews Date Review Type Description Assigned To Review Status 10/20/2021 Fire Alarm BUILDING In Review 10/20/2021 Fire Ala FIRE. In Review Fees Fee Description Notes Amount FACP/Transmitter New and/or Existing S200.00 Fire Alamt System Pen-nit NFPA 72- 105.7.3 S350.00 Processing/Technology Fee S25.00 Fire System Plan Review Table 4-2 or 4-10 S203.35 Total $77835 Notes Date Note Created By: 10/20/2021 Plan Review Fecs calculated on the application are incorrect. Raelynn Jones Uploaded Files Date File Name 10/20/2021 9941616-10-19 MOB Cut Shcets.pdf 10/20/2021 9941615-10-19 MOB Plans.pdf 10/20/2021 9941614-10-19 MOB Fire Alarnt.pdf NORTH COUNTY North County Regional Fire Authority 8117 267th Street NW Stanwood,WA 98292 Phone:(360)629-2184 Fax(360)652-3166 November 12, 2021 Permit Number: BLD 4199 Project Address: Smokey Point Medical Office 4011 172"d St. NE Arlington, WA Project Description: Fire Alarm Installation with AES Radio Communicator Contractor: Camryn Olivarez Fire Systems West, Inc. 206 Frontage Rd. N, Suite C Pacific, WA 98047 253-833-1248 Re: Fire Alarm Shop Drawing Review Comments The Arlington Fire Department has completed a review of the Fire Alarm shop drawing submittal and approves the submitted plans with the following conditions: 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch distributed power module to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the City of Arlington stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). 5. The record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call the City of Arlington inspection line at least 48 hours in advance to schedule an inspection. If there are any questions please do not hesitate to call. Sincerely, LeRoy W. McNulty Assistant Fire Chief North County Regional Fire Authority 360-629-2184 JFFICE COPY I I Fire ST' Fire Systems (Nest, Inc. Y ` "' 206 FRONTAGE ROAD NORTH, SUITE C PACIFIC, WA 98047 (253) 833-1248 :L '3 1 s FIRE ALARM Equipment Submittal FOR Smokey Point MOB 4011 172"d Street NE Arlington, WA 98223 Plan Review Received By OCT 2 p 2021 City of Arlington Honeywell FarenhytT"" Series THE POWER OF CONNECTED IFP-2100 / IFP-2100B / I RFP-2100 / RFP-2100B Scalable Analog/Addressable Fire Alarm Control System The IFP-2100(red)and IFP-2100B(black)are intelligent analog/ addressable Fire Alarm Control Panels(FACP).The basic IFP-2100 panel contains one built in signaling line circuit(SLC),which can support 159 System Sensor'IDP/SK sensors and 159 IDP/SK modules or 127 Hochiki" SD devices per loop.Additional SLC loops can be added using the model IFP-2100B 6815 SLC expander for IDP/SK devices to increase the overall point capacity to 2100 or model 5815XLfor SD devices to increase the overall point capacityto a maximum to 2032 points per panel. IFP-2100 has the interconnection capability for up to 32 panels.The system has two modes of operation,multiple panels covering one larger building,or multiple independent buildings.The RFP-2100(red)or RFP-2100B(black) can be used in a networked system where at least one IFP-2100 is in the system.It is the same as the IFP-2100 without the display. IFP-2100 has eight on-board Flexput"circuits that can be configured for auxiliary power,notification outputs,or for conventional smoke detector inputs(Class A or Class B).The FACP also has a Built in dual phone line digital alarm communicator/transmitter(DACT),IP or optional cellular RFP-2100B technologies,Form C trouble relay,and two programmable Form C relays. IFP-2100 has powerful features such as detector sensitivity,day/night thresholds,drift compensation,pre-trouble maintenance alert,and calibration trouble alert RF-P•"2.100 or • Four line I.CD display • Network card allows • JumpStart. • Supports up to four PFID-210013 can be with 40 characters per copper network Auto Programming' SWIFT wireless used in a networked line connection with a feature for easy gateways.Each system where at lease Available in a red or multi-mode or programming gateway can have up one:IFP-2100 is in the black cabinet singte-rnode fiber • Renewable license on to 49 wireless devices system connection option downloading software Supports Class B • IFP--7.100 or • Network support for •I2F'f 2100 can be Built-in dual phone helps inhibit (Style 4)and Class A surface or Fli_ish u a to 32 kites; line,digital alarm unauthorized (Style 6 or Stye 7 l • Built-in support for u mounted c:ornrnunic,ator/ programming configuration for SLC, pS p transmitter(DACT),II' and SBUS. to.1.59 IDP/SK • Four programmable • lluilt in lJSE3 interface detectors and 159 I g or optional cellular for programming IDP/`.il<modules or function keys technologies 1.27 SO SI-C devices IFP-2100 / RFP-2100 Technical Specifications PHYSICAL listing of the IDP,SK,SWIFT or SD devices. For a complete listing of all Overall Dimensions:26.4"H x 16.4"W x 4.11"D 3350361:IDP Device Protocol data sheet compliance approvals and certifications,please visit Shipping Weight:33 lbs. 53623:SK Device Protocol data sheet www.farenhyt.com. Color:Red or Black 350360:SD Device Protocol data sheet 350615&350617:SWIFT devices data sheet Microsoft,Windows,and ENVIRONMENTAL the Windows Logo are registered trademarks Operating Temperature:320 F to 1200 F (0o C to ORDERING INFORMATION or trademarks of 490C) IFP-2100:Intelligent Fire Alarm Control Panel.Red Microsoft Corporation. Humidity:0 to 93%relative humidity(non- Cabinet. SWIFT°and Honeywell' condensing) IFP-210OB:Intelligent Fire Alarm Control Panel, are registered trademarks Black Cabinet. of and FarenhytTl is a ELECTRICAL IFP-2100HV:High Voltage(240V)Intelligent Fire trademark of Honeywell IFP-2100 Primary AC:120VAC @ 50/60Hz,4.5A Alarm Control Panel.Red Cabinet International,Inc. IFP-2100HV AC:240VAC C 50/60Hz,2.8A IFP-2100HVB:High Voltage(240V)Intelligent Fire This document is not Total Accessory Load:9A C 24VDC power-limited Alarm Control Panel.Black Cabinet intended to be used for Standby Current:230mA RFP-2100:Remote Fire Alarm Panel without built installation purposes.We Alarm Current:415mA in display,Red Cabinet, try to keep our product RFP-210OB:Remote Fire Alarm Pane[ built information to Battery Charging Capacity:17 to 55AH date and accurate.We Battery Size:18AH max.allowed in control panel in display.Black Cabinet. cannot cover all specific cabinet.Larger capacity batteries can be housed in RFP-2100HV: High Voltage(240V)Remote Fire applications or anticipate RBB accessory cabinet. Alarm Panelwithout built in display.Red Cabinet. all requirements.All Six Conductor Wiring:Two voice bus&four SBUS RFP-2100HVB: High Voltage(240V)Remote Fire specifications are subject Alarm Panelwithout built in display.Black Cabinet. to change without notice. FLEXPUT CIRCUITS For Technical Eight circuits that can be programmed SBUS ACCESSORIES Support,Please call individually as: RA-2000,RA-1000,RA-1000R,RA-100, 800-446-6444. Notification Circuits:3A per circuit C 24VDC, RA-2000GRAY:Remote annunciators power limited 6815:Signal Line Circuit(SLC)Expander for IDP or Auxiliary Power Circuits:3A per circuit @ 24VDC, SK devices power limited. 5815XL:Signal Line Circuit(SLC)Expanderfor SD Initiation Circuit:100mA per circuit C24VDC, devices power-limited RPS-1000/B:Power Supply.Red or Black Cabinet 5496:NAC Expander AGENCY LISTINGS AND APPROVALS 5824:Serial/Parallel Module NFPA 13,NFPA 15,NFPA 16,NFPA 70,&NFPA 5880:LED 1/0 Module 72:Central Station;Remote Signalling;Local 5865-3 or 5865-4:LED Annunciator Protective Signalling Systems;Auxiliary Protected 5883:Relay Interface Premises Unit;&Water Deluge Releasing Service UL Listing MISCELLANEOUS ACCESSORIES CSFM 7165-0559:0505 FDNY COA#6251 HFSS:Software Suite.Provides programming, upload/download and event reporting Seismic(CA)(pending) RBB:Remote Battery Box Cabinet.Use for backup FM approved batteries up to 35AH.Dimensions:16"W x 10"H x 6"D APPROVED RELEASING SOLENOIDS SK-SCK:Seismic Compliance Kit Asco T821OA107 24 VDC 3 A max 0 Hz SK-NIC:Network Interface Card Asco 821OG207 24 VDC 3 A max 0 Hz SK-FML:Multi Mode Fiber Card SK-FSL:Single Mode Fiber Card COMPATIBLE DEVICES CELL-MOD:Cellular Communicator in Plastic See the data sheets listed below for a complete Enclosure CELL-CAB-SK:Cellular Communicator in Metal For more information Enclosure with lock and key Learn more about Honeywell's Farenhyt Series and other products available by visiting www.fa ren hyt.co m> Honeywell Farenhyt 12 Clintonville Road Northford,CT 06472 3516021 A 101/18 Honeywell 800-328-0103 ©2018 Honeywell International Inc. i`B W aes-corp.com ES .jS1"'CLIH1IN' CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options �L • Engineered for backward compatibility with legacy systems N�, LISTED > p Y g Y Y • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies(MCT)feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options; (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards - sStl Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network.The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines, The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status, The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop,tablet, or integrated Universal Serial Bus (USB)---without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary 0 Subscriber C I �I B)Fire �� i ♦ / Subscriber r r' AES-Ne—rk&I-agement system --—————————--——-——— ww D �'t�"-— B Prlinary AFSM1fultlNcr Rccclvar / , r A)Alarm Panel e I Secondary AES 4fultlNet aeceNer C Alarm Automation _ A --- - ------- --"' C)IPLinks Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel&AES Subscriber Multi-path AES-IntelliNet(®Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board, AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units.A FACP Power Supply Adapter is required for certain configurations when using flexible power options.The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time, The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/pro+ducts/fire/fare-marshal-resources How to Order 7707 Fire SubscribersIntelfiNet 2.0 Fire 2.0 PREMIUM (UL&ULC Listed) 7707P 88 M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber,44 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCI, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy • • - 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744E-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber, 44 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber, 44 Zone,4 Reversing Polarity, 4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.01.type zone inputs and message communication 4+4:4 reverse polarity input and USB access for software upgrade W El G HT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L. type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-Intellift for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem IIla2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470 MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop,or PC ANTENNA Receiving Centres and Systems 2.5 d13 tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+ charging backup battery: Form C relay, fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE. ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60°C) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell,size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237- ,87 or email :,alf�s@ae.-cor .coo . f 0 y v o Peabody, • United States r SILENT Farenhyt KNIGHT by Honeywell AnnunciatorRemote Remote Annunciator Agency Listings RA-1000 U F M M EA L429-92-E Vol IX The RA-1000 is a remote annunciator used to operate and nvvuoveo program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the IFP-1000 control panel. The remote annunciator connects -�"-""' to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power d LED is lit and all other LEDs are off. The other LEDs turn on U U Ll as alarms, supervisories, troubles, system silenced and AC , U Q[a power losses occur. O a Q Features • 80-character backlit LCD display (4 lines with 20 characters on each line) -A-1e0i • Tactile and audible feedback • Accepts user codes or fire fighter's key Installation • Larger keypad buttons for system reset and silence The RA-1000 can be surface or flush • RS-485 interface to panel mounted. Use the optional trim ring for surface • Operation and appearance is identical to IFP-1000 built-in mounts. When flush mounting an electrical annunciator box is optional. If using an electrical box, use • Install up to eight RA-1000s per FACP a 4S, single-gang, or double-gang box. • Support for simultaneous use of multiple RA-1000s Compatibility • On-board piezo sounder audibly indicates alarms, troubles, The RA-1000 is compatible with the following and supervisories FACPs: • Five status LEDs for alarm, supervisory, trouble, silence and IFP-1000ECS Emergency Communication AC power conditions System with Fire Alarm Control Panel • Available in red or light gray IFP-100ECS Emergency Communication • Wiring lengths up to 6000 ft. from the FACP (depending on System and Fire Alarm Control Panel wire gauge and number of devices on SBUS) IFP-1000 Intelligent Fire Panel • UL listed, complies with NFPA 72 IFP-100 Intelligent Fire Panel • CSFM approved • IFP-50 Intelligent Fire Panel • MEA P/N 350071 Rev D Copyright©2012 Honeywell International Inc. FlexputTM is a Trademark of Silent Knight JumpstartO is a Registered Trademark of Silent Knight IFP-1000 FACP f RA-1000 RA-1000 RA-1000 � ! •1 � ®YVU � � �YVO 7 • Up to 8 RA-1000 per system •80-character backlit LCD display (4 lines with 20 characters each) •Wiring lengths up to 6000 ft.from the control panel Specifications Approvals Physical NFPA 72 Height: 7.4" (18.8 cm) UL Listed; Width: 9.1"(23.1 cm) CSFM 7170-0559: 135; Depth: 1.5" (3.8 cm) MEA 429-92-E Vol. IX; Shipping Weight: 2.8 Ibs (1.3 kg) FM Approved Color Ordering Information RA-1000R: Red g RA-1000: Gray RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Electrical Red. Operating Voltage: 24 VDC RA-1000 Remote Annunciator. Four line LCD Standby Current: 20 mA max annunciator with 20 characters per line. Alarm Current: 25 mA Gray. Accessories Wiring Distance: 6,000 max. from FACP(depending on wire 5860TR Red Trim Ring. For surface mounting. gauge and number of devices on the SBUS) 5860TG Gray Trim Ring. For surface mounting. Max Per System: 8 Environmental Operating Temperature: 32°F— 120°F (0°C—49°C) Humidity: 10%—93% non-condensing SILENT This document is not intended to be used for installation purposes.We try to keep our r KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800)328-0103, Fax: (203)484-7118. www.farenhyt.com Made in the U.S.A. Honeywell Farenhyt"' Serifs THE POWER OF CONNECTED Farenhyt IDP-PHOTO-W Series Intelligent Plug-in Photoelectric Smoke Detectors Honeywell's IDP-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics,A new modern,Meek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The IDP-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel,Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. IDP-PHOTO-W in B300-6 base Dual electronic thermistors add 135°F(5710 fixed temperature thermal serisirry uri LIw I DP-PHOTO-T.Tl w IDP-PHOTO-R Is a rumul.0 Luslcapabte detector for use with DN R Series duct detector housings • New modern profile • Optional remote, • Built-in tamper- • Optional relay, for improved single-gang LED resistant feature isolator,and sounder aesthetics accessory . Sealed against back bases • Stable communication • Dual LED design pressure • Plugs into separate technique with noise provides 3600 viewing . Expanded color base for ease of immunity angle options installation and • Low standby current • Remote test feature ,G maintenance • EMS screws for panel• Two-wire SLC from the p wiring of the separate connection • Built-in functional test base switch activated by external magnet DETECTOR SPACING AND IDP-PHOTO-R-W:White,low-profile ACCESSORIES APPLICATIONS intelligent photoelectric sensor,remote CK300:Color Kit(includes cover and Honeywell recommends spacing test capable.For use with DNR/DNRW.. trim ring),white,10-Pack. detectors in compliance with NFPA 72. IDP-PHOTO-R-IV:Ivory,low-profile CK300-IV: Color Kit(includes cover and In low airflow applications with smooth intelligent photoelectric sensor,remote trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m).For test capable. For use with DNR/DNRW. CK300-BL:Color Kit(includes cover and specific information regarding detector trim ring),black,10-Pack. spacing, INTELLIGENT BASES g p g,placement,and special 13300-6:White,standard flanged M02-04-01:Detector test magnet. applications refer to NFPA 72.System Smoke Detector Application Guide, low-profile mounting base. M02-09-00:Telescoping test magnet. document A05-1003,is available at B300-6-BP:Bulk pack of B300-6, RA10OZ:Remote LED annunciator systemsensor.com package contains 10. SMB600:Surface Mounting Kit B300-6-IV:Ivory,standard flanged (flanged). INSTALLATION low-profile mounting base. TR300:Replacement trim ring for B300- The IDP-PHOTO-W Series plug-in B501-WHITE:White,standard European 6,white. detectors use a separate base to simplify flangeless mounting base.UL listed. TR300-IV:Replacement trimring for installation,service,and maintenance. B501-BL:Black,standard European B300-6-IV,ivory. Installation instructions are shipped with flangeless mounting base.UL listed. each detector. B501-IV:Ivory,standard European Mount base(all base types)on an flangeless mounting base.UL listed. electrical backbox which is at least 1.5 B20OS-WH:White,Intelligent, (3.81 cm)deep. programmable sounder base. B20OS-IV:Ivory,Intelligent, NOTE: programmable sounder base. • Because of the inherent supervision B200SR-WH:White,Intelligent sounder provided by the SLC loop,end-of-line base for retrofit applications. resistors are not required.Wiring"T-taps" B200SR-IV:Ivory,Intelligent sounder or branches are permitted for Style 4 base for retrofit applications. (Class"B")wiring. B20OS-LF-WH:White,Low Frequency •When using relay or sounder bases, Intelligent,programmable sounder base. consult the installation sheet for device B20OS-LF-IV:Ivory,Low Frequency limitations between isolator modules Intelligent,programmable sounder base. and isolator bases. B200SR-LF:White,Low Frequency Intelligent sounder base for retrofit ORDERING INFORMATION applications. NOTE:Detectors must be mounted to one B200SR-LF-IV:Ivory,Low Frequency of the Intelligent Bases listed below Intelligent sounder base for retrofit IDP-PHOTO-W:White,low-profile applications. intelligent photoelectric sensor. B224RB-WH:White,plug-in System IDP-PHOTO-IV:Ivory,low-profile Sensor relay base. intelligent photoelectric sensor. B224RB-IV:Ivory,plug-in System IDP-PHOTO-T-W:White,same as the Sensor relay base. IDP-PHOTO-W,but includes a built-in B224BI-WH:White,plug-in System 135°F(57°C)fixed-temperature thermal Sensor isolator detector base. device. B224BI-IV:Ivory,plug-in System Sensor IDP-PHOTO-T-IV:Same as IDP- isolator detector base. PHOTO-T but in Ivory. Farenhyt IDP-PHOTO-W Series Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The IDP-PHOTO-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Farenhyt Series www•farenhyt.com. base 4.1"(104 mm)installed in 8501 base FACPs: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) - IFP""2.1.00/IFI'"'"21.00ECS/UP-21.00 registered trademarks or trademarks of ENVIRONMENTAL - IFP--2000/ IFP-2000ECS/RPS-2000 Microsoft Corporation, Operating Temperature range: - IFP--1000/IFP-1000E.0 S Honeywell'and Sysleiii Sensui'ale Photo:320Fto122oF(OoCto50"M - IFh-300/iFP-;;300E(S registered trademark trademark and Farenhyt'" is a Photo with Thermal:32°F to 100°F(0°C to • IFP-too/IFP-t.00Er.:y trademark of Honeywell 380C) International,Inc. Thermal Ratings:Fixed Temperature Set point: • IFP-(.5 This document is not ® 1 FP-50 intended to be used for 1350 F(570 C) installation purposes.We Sensitivity:ULApplications:0.5%to 4.0o/o per tryto keep our product AGENCY LISTINGS AND APPROVALS information up-to foot obscuratlon. date and accurate.We For exact certification listings for each model, cannot cover all specific ELECTRICAL RATINGS please reference the respective agency Web site. applications or anticipate all requirements.All Voltage Range:15 to 32VDC peak UL listed:S6113 specifications are subject to change without notice. Operating Current C 24VDC:200i A(one FM approved For Technical communication every 5 seconds with green LED CSFM:7272-0559:0512 Support,Please call blink on communication) 800-446-6444. Maximum Current:4.5mA(a-)24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.fa re n hyt.co m Honeywell Farenhyt 12 Clintonville Road Northford,CT 06472 Doc351629I Rev Al04/18 Honckmell 800-328-0103 ©2018 Honeywell International Inc, 07 SILENT Farenhyt 0 KNIGHT by Honeywell Intelligent Device Addressable Monitor Module Agency Listings IDP-Monitor '' S M EA The IDP-Monitor is an addressable monitor module for use with ,'•. ... 386-0-E-Vol 2 Rv Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Monitor acts as an interface to contact devices, such as waterflow switches and pull stations. - The IDP-Monitor supports Class A supervised or Class B - supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble •''� ,� .,� conditions. �. to Features k • Single contact monitor • Support for Class A and Class B wiring IDP-Monitor • Fully supervised • Panel controlled status LED that flashes green in normal state Compatibility and is solid red in alarm The IDP-Monitor is compatible with the following FACPs: • Attractive ivory cover plate • Rotary address switches for fast installation • IFP-2000 / RPS-2000 Intelligent Fire Panel • SEMS screws for easy wiring • IFP-2000ECS Emergency Communication • UL Listed System with Fire Panel • IFP-1000 / ECS Intelligent Fire Panel Installation • IFP-100/ ECS Intelligent Fire Panel The IDP-Monitor mounts directly into a 4" square electrical box. • IFP-50 Intelligent Fire Panel The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor® PN SM6500) is available from Silent Knight. P/N 350288 Rev J Copyright©2015 Honeywell International Inc. TO NEXT — ^ � FROM PANEL OR � DEVICE c t PREVIOUS DEVICE mnNITnR ANY NUMBER OF UL LISTED CONTACT MODULE CLOSURE DEVICES MAY BE USED.DO NOT MIX CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INITIATING,SUPERVISORY,OR 1O Q CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. a o ro ® n H (+j EOL T RESISTOR STOR ELR-47K vow o aw o ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED INITIATING DEVICE CIRCUIT(IDC)-NFPA STYLE 8 POWER LIMITED:450pA MAX.a 11 VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXT FROM PANEL OR DEVICE �� �'� PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT rn MODULE CLOSURE DEVICES MAY BE USED.DO NOT MIX CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INITIATING,SUPERVISORY,OR O Do CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE ° n EOL RESISTOR IS INTERNALA7 TERMINALS B&9 ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications Environmental Physical Operating Temperature: 32°F— 120°F (0°C —49°C) Height: 4.5" (11.4 cm) Humidity: 10% —93% non-condensing Width: 4" (10.2 cm) Ordering Information Depth: 1.25" (3 cm) IDP-Monitor Monitoring Module Shipping Weight: 6.3 oz (196 g) Accessories Electrical SMB500 4" Square Surface Mount Electrical Box Operating Voltage: 15— 32 VDC SLC Standby and Alarm Current Draw: 350 pA End-of-Line Resistance: 47K 0 Max. IDC wiring resistance: 1,500 n Max. IDC Voltage: 11 Volts Max. IDC Current: 450 pA SLC Loop Resistance: 40 0 max. SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to- / date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are KNIGHT subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax:(203)484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com Farenh t SILENT Y KNIGHT by Honeywell Addressable Relay Module Agency Listings IDP-Relay ,.,�� MEA The IDP-Relay is an addressable relay module for use with 386-02-E Vol II Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The IDP-Relay contacts can be used for virtually any normally open or normally closed application. Each UP-Relay is '�r programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the IDP-Relay, 7• the relay is triggered by the FACP. •�- e�` ` Features —� • Two sets of Form C contacts IDP-Relay • Contacts are rated for a variety of amps (see Specifications) Compatibility • Panel controlled status LED that flashes green in normal The IDP-Relay is compatible with the state and is solid red in alarm following FACPs: • Relay programming is completely flexible—can be mapped . IFP-2000 / RPS-2000 Intelligent Fire Panel to zone conditions • Polling LED visible through the cover plate • IFP-2000ECS Emergency Communication System with Fire Panel • Attractive ivory cover plate • IFP-1000/ ECS Intelligent Fire Panel • Rotary address switches for fast installation • IFP-100 / ECS Intelligent Fire Panel • SEMS screws for easy wiring • IFP-50 Intelligent Fire Panel • UL Listed Relay Contact Ratings • IFP-25 Intelligent Fire Panel Current Max Voltage Load Application Installation Rating Description The IDP-Relay mounts directly into a 4" 3 A 30 VDC Resistive Noncoded square electrical box. The box must have a minimum depth of 2-1/8". A surface mount 2 A 30 VDC Resistive Coded electrical box (System Sensor® PN SMB500) 0.7 A 70.7 VDC PF =0.35 Noncoded is available from Silent Knight. 0.9 A 125 VAC Resistive Noncoded 0.46 A 30 VDC L/R=20 ms Noncoded 0.5 A 125 VAC PF = 0.75 Noncoded 0.3 A 125 VAC PF = 0.35 Noncoded 2 A 25 VAC PF= 0.35 Noncoded P/N 350290 Rev J ©2015 Honeywell International Inc. CONNECT MODULES TO LISTED COMPATIBLE I-) CONTROL PANELS ONLY. t-) FROM PANEL TO NEXT OR PREVIOUS DEVICE +) 1) DEVICE RELAY CONTROL MODULE If any wiring to Terminals 4-10 is Nonpower limited,The CB500 barrier O O is required.The CB500 includes a Nonpower limited label,which To e o must be pieced over the Power TV Limited terminal information on t (-) the name plate label. Relay Common 2 Ttp T Normally Closed 2 ` T9 T2 t+) Normally Open 2 Te T3 Relay Common 1 Tn T4 Unused Normally Closed 1 T6 ; a ; Ts Normally Open 1 e aa� TENS a oNes C� *NOTE:ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. Specifications Ordering Information Physical IDP-Relay Relay Module 4.675" H x 4.275" W x 1.4" D Shipping Weight: 6.3 oz (196 g) Accessories Environmental SMB500 4" Square Surface Mount Electrical Box Operating Temperature: 320F— 120OF (0°C —49°C) CB500 Module Barrier Humidity: 10% —93% non-condensing Electrical Operating Voltage: 15—32 VDC End-of-Line Resistance: Not used SLC Standby&Alarm Current: .255mA max @ 24 VDC (one communication every 5 sec with LED enabled) SILENT This document is not intended to be used for installation purposes,We try to keep our product Information up-to-date and accurate.We cannot cover all specific applications or KNIGHT anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103,Fax:(203)484-7118. For Technical Support, Please call Assembled In Honeywell 800-446-6444. www.farenhyt.com U.S.A. SYSTEM SENSOR 5600 Series Mechanical Heat Detectors 5601P System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. 35T15' 5621 Features Multiple configurations.The 5600 series offers a full-line of • Multiple configurations for installations: configurations to accommodate a broad range of applications. Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(FOR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations(Model 5601 P) • Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, • Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5""and 4"Octagonal when used with a square to round plaster ring.The reversible —4"square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. • Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/ rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings U M g LISTED 82101 3016008 CS630 7270-1653 0167 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 1940F(90oC),and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor.The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Maximum Installation Temperature 5601 P,5603,5621,and 5623: 100°F(38°C) 5602,5604,5622,and 5624: 150°F(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1,69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623: 135°F(57°C) 5602,5604,5622,and 5624: 194°F(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 150F(8.3°C)rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Flectric�jl Specifications Operating Voltage/Contact 6-125VAC/3A Ratings 6-28VDC/I 125VDC/0.3A 250VDC/0.1 A Input Terminals 14-22 AWG na'>W u )U O O O O O 5601 P 5602, 5622 5603,5623 5604,5624 5621 Ordering Information MethodIdentification i Foot Model Circuit on Exterior Rating Activation Ceiling.* 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7,62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) "NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. �1K� SySTEm 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fax: 630-377-6495 Prcduclspecificat:onssubjecilochangewithoutnolice.Visilsyslemsensoccom SENS®R' or current product information,ncludng the latest version of this data sheet. www.systemsensor.com SPDS30001•7113 Honeywell Farenhyt" Series THE POWER OF CONNECTED IDP-PULL-SA / IDP-PULL-DA Addressable Single Action and Dual Action Pull Stations The IDP-PULL-SA is a single action pull station requiring only one motion to activate the station,The IDP-PULL-DA is a dual action pull station requiring two motions to active the station.Both pull stations are designed to work with Honeywell Farenhyt series fire alarm control panels(FACPs), INSTALLATION The IDP-PULL-SA and IDP-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm)or double gang or 4"(10.61 cm)square electrical box.You can also use the optional(System Sensor,)PN BG-TR) Honeywell trim ring if the station is being semi-flush mounted. IDP-PULL-SA COMPATIBILITY The IDP-PULL-SA and IDP-PULL-DA are compatible with the following Honeywell Farenhyt Series FACPs: • IFP-2100/IFP-2100ECS/RFP-2100 • IFP-2000/IFP-2000ECS/RPS-2000 • IFP-1000/IFP-1000ECS • IFP-300/IFP-300ECS • IFP-100/IFP-100ECS Honeywell • IFP-75 • IFP-50 IDP-PULL-DA Is F_ A l.J P l.:S &I F E. rN l_m w: I S • Installer can open • Key operated test and Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition Guidelines(ADAAG) appears,clearly • Key matches Braille text ore station • Dual-color LED is compatible:FACP controls and operating handle indicating the station visible through handle locks mechanisms has been pulled guidelines(Section • Rotary address of station blinks green Meets ADA switches for fast UL.!_fisted,including +.:1.:3[13]J to indicate normal UL 38,StandarrJ of operation and remains requirement for 5 lbs maximum pull force to ` `'hell,door,and handle installation Manually Actuated steady red in an alarm active molded from durable: Signaling System condition LEXAN' CSFM Listed • MEA Listed IDP-PULL-SA and IDP--PULL-DA Technical Specifications For a complete listing of all a compliance approvals and certifications,please visit www.farerihyt.com. Microsoft,Windows,and the Windows Logo are registered trademarks ortrademarks of Cgnpatible FACP j Microsoft Corporation. in n Ion , .:. Honeywell'and i t Syslenl Sensul'dle registered trademarks of and Farenhyt-Is a �uaA wnq,= trademark of Honeywell Glasa q Wllwq•- __ , International,Inc. Ming IDP.PullSA A IDP.PuII.DA Pull Slellona This document is not intended to be used for installation purposes.We SPECIFICATIONS" ORDERING INFORMATION tryto keep our product Physical:5.5"H x 4"D(14cm x 10.2cm) IDP-Pull-SA:Single Action Pull Station information up-to Shipping Weight:5.4oz IDP-Pull-DA:Dual Action Pull Station date and accurate.We ic Housing Material:LEXAN polycarbonate resin cannot cover r anticipate applications or anticipate Bi-Colored LED: ACCESSORIES all requirements.All Blinking Green:Normal BG-TR:Optional trim ring. specifications are subject Steady Red:Alarm SB-I/O:Surface backbox,indoor/outdoor. to change without notice. Switch:Single pole,single throw(SPST)normally "Unless otherwise noted,specifications apply to For Technical open(N/O)switch which closes upon activation of IDP-Pull-SA and IDP-Pull-DA Support,Please call the pull station 800-446-6444. ELECTRICAL RATINGS Operating Voltage:15—32VDC SLC Standby and Alarm Current:350µA Wire Gauge:Up to 12AWG(3,1 mmz) ENVIRONMENTAL Operating Temperature:32D-120°F(0°C—49°C) Humidity:10 to 93%non-condensing) For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www,fa ren hyt.com Honeywell Security 81 Fire 12 Clintonville Road Northford,CT 06472 Doc 3502e61 Rev H 111117 Honeywel 800-328-0103 ©2017 Honeywell International Inc. /-1 Mounting g Mounts directly to 4-square electrical boxes (see Figure KNIGHT2A).The box must have a minimum depth of 21/8". Surface mounted electrical boxes (SMB500) are available from Silent Knight. by Honeywell Wiring NOTE: All wiring must conform to applicable local INSTALLATION AND MAINTENANCE codes,ordinances, and regulations.This module is in- INSTRUCTIONS tended for power limited wiring only. IDP-Monitor-2 1. Install module wiring in accordance with the job draw- Dual Monitor Module ings and appropriate wiring diagrams. 2. Set the address on the module per job drawings, Note: Monitor module L (using terminals 6 and 7) re- Specifications sponds at the address set on the code switches.Monitor Normal Operating Voltage: 15 to 32 VDC module H (using terminals 8 and 9) will automatically Maximum Current Draw: 5.7 mA(LED on) respond at the next higher address. For example,if the code switches are set to 76, module L will respond at Average Operating Current: 750µA(LED flashing) address 76 and module H will respond at address 77. EOL Resistance: 47K Ohms Use caution to avoid duplicate addressing of modules Max. IDC wiring resistance: 1,500 Ohms on the system. Temperature Range: 32°F to 120'F(0°C to 49°C) 3. Secure module to electrical box(supplied by installer), Humidity: 10%to 93%Non-condensing as shown in Figure 2A. Dimensions: 4'/2'H x 4'W x V/4-D (Mounts to a 4-square by 2'/8-deep box,) Figure 1. Controls and Indicators: Accessories: SMB500 Electrical Box Before Installing 0 0 O This information is included as a quick reference instal- 9 5G0 o lation guide. Refer to the control panel installation man- Figure 2A. 8 z``Y t g ual for detailed system information. If the modules will 7 2 Module mounting: s 45ore„ s be installed in an existing operational system, inform the operator and local authority that the system will be tem- s a�'2�D 4 ES porarily out of service. Disconnect power to the control «P ADDRESS 0 panel before installing the modules. C� Q 0 NOTICE: This manual should be left with the owner/ user of this equipment. a® co21e-o1 General Description The Dual Monitor Module is intended for use in intel- ligent,two wire systems. It provides two independent I I Figure 213: 2-wire initiating device circuits (IDC), at two separate, consecutive addresses. It is capable of monitoring nor- ° o mally open contact fire alarm and supervisory devices,or o either normally open or normally closed security devices. c ® m The module has a single panel controlled red LED. � e Compatibility Requirements I 6 o To ensure proper operation,this module shall be con- . nected to a compatible Silent Knight system control panel n 0 (list available from Silent Knight). C0157-00 C0156-00 K200-13-00 1 156-2730-002 Figure 3.Typical 2-wire initiating circuit configuration, NFPA Style 13: TO NEXT E—I-�_ FROM PANEL OR DEVICE �'0_/���� ����� � PREVIOUS DEVICE TWO INITIATING DEVICE CIRCUITS(L&H), EACH POWER LIMITED TO 230µ4®12VDC MAX. MONITOR MODULE CONNECT MODULES TO LISTED COMPATIBLE �� SILENT KNIGHT CONTROL PANELS ONLY 47 K EOL RESISTOR /) RESR H lJ ELR-47K ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED 7 7 1r1 R 47 K EOL \ $1G4N�SdRCSl1?.l$LCl RESISTOR L 32VDCMAX ELR-47K o SHIELDED-TWISTED PAIR 00 IS RECOMMENDED ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED.DO NOT MIX FIRE ALARM INITIATING,SUPERVISORY,OR SECURITY MONITOR A(TERMINALS 6&7)RESPONDS ATADDRESS DEVICES ON THE SAME INITIATING DEVICE CIRCUIT. SET ON CODE SWITCHES.MONITOR B(TERMINALS 6&9) C0609-01 RESPONDS AT NEXT HIGHER ADDRESS. INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3 SILENT KNIGHT by Honeywell 7550 Meridian Circle Maple Grove,MN 55369-4927 763-493-6455; 800-328-0103 Fax: 763-493-6475 http://www.silentknight.com ©2006 Silent Knight 2/06 K200-13-00 2 156-2730-002 SYSTEM �4 SENSOR- Indoor Selectable- +r •, Output Strobes and Horn Strobes for Ceiling Applications t System Sensor L-Series audible visible notification products are rich with features guaranteed to cut - installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115. 150.and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & ..� LISTED FM approved except 7125-16530504 for ALERT motlels 7135-1653:0503 3057383 AVDS066-02•12/01/2017•Page 3 L-Series Specifications Architect/Enginleer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1 Y2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'°"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system, Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires,The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit,The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDSBBB-02-12/01/2017-Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL May.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 31 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Strobe,UL Max.Current Draw(mA RMS),Ceiling Horn 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn ..• • .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.6 mm) 6 92"diam. 2 5' 6(17 diam3 mm). (175.77 mm) (64 mm) 17 ner r�rrr fiA( O Bn7 O o CDo 1 0 00 0 o p o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box o � 0 O �M{1r�tt1 �J V►S ® 0 O 0 ® O i A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Descriptiono- o Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". �STLM IL ©2017 Syslem Sensor. 3825 Ohio Avenue-St.Charles, 60174 Product specilical,ons subject to change without notice.Visit systemsensoccom SENSOR Phone:800-SENSOR2-Fax: 630-377-6495 for current product information,including the latest version ol[his data shoal AVDS866-02-12101/2017 SYSTEM SENSOR Outdoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert®Advance outdoor audible visible products SPECTRAlert are rich with features that cut installation times and A n v A na c E maximize profits, Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof NEMA 4X, IP56 rated strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151°F. • Field-selectable candela settings: 15, 15/75,30,75. 95. 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor strobes and horn strobes for ceiling applications include a variety of features that • Automatic selection of 12-or 24-volt operation at 15 and increase application flexibility and simplify installation. First,field- 15/75 candela selectable settings,including candela,automatic selection of 12-or • Rotary switch for horn tone and three volume selections 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Plastic and metal weatherproof back boxes come with �` 3/4-inch top and bottom conduit entries and 3/4-inch knock-outs at the back.Three screw-in NPT plugs with O-ring gaskets for a watertight > a LISTED F M MEA 7300-1653:167(outdoor strobes) approved 7125-1653:188(hornstrobes, seal is included with each back box. 54011(chimes,horn strobes,horns) nvvacv`° chime strobes) 53593(outdoor and alert strobes) 30 MEA452-05-E 7135-1653:189(horns,chimes) SpectrAlert Advance Outdoor Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four- wire products,the strobe shall be powered independently of the sounder.The horn strobe on a 2-wire model shall work on a non-coded power supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments. OperelbrgTemperalure —40°F lu 151°F(-40°C lu 88°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Flange with MDL3 Sync Module 8.5 to 17.5V(12 V nominal)or 16.5 to 33V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8""diameter x 2.5""high(173 mm diameter x 64 mm high) Strobe/Horn Strobe Dimensions 5.6-L x 4.7-W x 1.3""D(142 mm L x 119 mm W x 33 mm D) Strobe/Horn Strobe Dimensions with Back Box 5.6""L x 4.7"W x 1.3""D(142 mm L x 119 mm W x 33 mm D) Ceiling-Mount Weatherproof Back Box Dimensions 7.1"diameter x 2.0""high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Products will operate at 19 V nominal only for 15 and 15/75 od. AVDS11401 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current • aw for 4-Wire Horn Strobes(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listedHorn Strobe Output candela ratings must be reduced in accordance with 8--17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 135 135 Temporal 75 75 81 81 88 84 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. Avos11401 SpectrAlert Advance Diagrams 6.8' Dia. T2.5' O 0 o Ceiling-Mount Horn Strobes Ceiling Plastic Weatherproof Back Box 0 0 d Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information DescriptionModel Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) PC2RHK 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) PC2WHK 2-Wire,Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Ceiling Strobes SCRK Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SCWHK Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SCWK Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SCWHK Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Accessories SA-WBBC Red,Metal Weatherproof Back Box SA-WBBCW White,Metal Weatherproof Back Box MP120K Motes: "Standard cd"refers to strobes that include 15,15/75.30.75,95.110,and 115 candela settings."High cd"refers to strobes that include 135.150,177,and 185 candela settings.When replacing outdoor units,both the device and back box must be replaced. �� ) S�.STEM ©2015 System Sensor. SENSOR Phone: Ohio Avenue•St.Charles, IL 60174 Pforcurre ecroduonssrmati to change ngthelatestvesionolystemstasheet Phone:800 SENSOR2•Fax:630 377-6495 or current product informaliAVDS11402-02/15sl version of this data sheet AVD511402•02/15 SYSTEM SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTRAWd SpectrAlert®Advance outdoor audible visible products A n v a N c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151°F. • Field-selectable candela settings: 15. 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones, and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications,This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill �L holes for screw-in mounting. Plastic and metal weatherproof back n/� p boxes come with 3/4-inch top and bottom conduit entries and 3/-inch LISTED FM ME" 7300- -,,,,(ou1door strobes) approved 7125-1653166(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket 54011(chimes,horn strobes,horns) APPROVEDpprove chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653 1139(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuitT Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110. 115. 135, 150, 177.and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40^F to 151"F(-40"C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) InputTerminaf Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2. P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data StrobeUL Max. 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current r . .. 8-17.5 Volts 16-33 Volts DC Input 15 15f75 15 15f75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 Strobe,UL Max.Current Draw(mA RNIS),2-Wire Horn 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with this table. •8-17.5 16-33 24-Volt Nominal Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40oF 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 St Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. Avos0120i SpectrAlert Advance Diagrams �4.7 5.6" O 0 LR Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box O Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Descriptionz Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red.Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: •Add '-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate.WTP and WTPW. "Standard cd"refers to strobes that include 15, 15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 165 candela settings.When replacing standard outdoor units both the device and back box must be replaced. rEM S ©2012 System Sensor, 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject tochange without notice,visa syslemsensoccom SENSOR Phone:800-SENSOR2•Fax:630-377-6495 or Currentproduclinbrmation,D,90 2 1 3/1leslversionol his data sheet, nvosolzol•snz FIRE ALARM PERMIT APPLICATION °j Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-35SI Type of Permit: ® New Installation System Modification ❑ Phased Installation Property Address: 4011 172nd Street NE Project Valuation: 11,500 Lot#: Parcel ID No.: 31052100306700/-600/-500 Preferred Contact: 73 Owner X Contractor Project Description: Install new FACP, radio, and annunciator. Install new notification devices for shell layout Inst III new devices for elevator recall. Owner Name: Market Street Development Home No.: 206-658-5922 Email Address: she]don t5marketstreetdev.com Cell No.: Mailing Address: 1602 Colby Avenue City: Everett State: WA Zip: 98201 Contractor Name: Fire Systems West. Inc. Office No.: 253-833-1248 Email Address: camrynoafiresystemswest.com Cell No.: 253-431-5860 Mailing Address: 206 Frontage Rd N. Suite C City: Pacific State: WA _ Zip: 98047 L&I Contractor License Number: FIRESWI055LW Expiration Date: 06/16/2021 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES AND TWO (2) SETS OF THE FOLLOW: I� Complete and Scaled Plans Specification Sheets ® Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Camr n Olivarez 10/19/2021 Signatur Print Name Date R STAFF USE ONLY 1-4 PERMIT# ACCEPTED BY: DATE STAMP REV12.2020 Page 1 oF2 FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at time of application submittal (Table 4-10) Less than $5,000.00 = $100.00 • (Table 4-2) $5,000.00 &over = based on valuation REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ `tI Lli i00 $375.00 - $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ ® NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 100 $350.00 = $ 350 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $ 200 PERMIT FEE SUBTOTAL $ 550 PERMIT FEE TOTAL $ 550 PLAN REVIEW FEE $ 357.50 Processing/Technology Fee $25.00 TOTAL $ 932.50 REV12.2020 Page 2 of 2 '" ° FIRE ALARM PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) 0✓ New Fire Alarm Fire Alarm Alteration/Addition Project Address: 4011 172nd Street NE Parcel ID#: 31052100306700/-600/-500 Number of Zones/Panels:1 FACP Building Area(Sq Ft)' 64,431 Valuation: 11,500 Owner: Market Street Development Phone Number: 206-658-5922 Address: 1602 Colby Avenue Everett WA 98201 City: State: Zip Code: Contact Person:Camryn 0livarez Phone Number: 253-431-5860 Email: Cell Phone: 253-833-1248 camryno@firesystemswest.com 206 Frontage Rd N, Suite C Pacific WA 98047 Address: City: State: Zip Code: Contractor: Fire Systems West, Inc. 253-833-1248 Phone Number: Address: 206 Frontage Rd N, Suite C City: Pacific State: WA Zip Code:98047 FIRESWI055LW 06/16/2023 Contractor's License Number: Expiration: Contact Person: Camryn Olivarez camryno@firesystemswest.com Email: _ Electrical contractor, Fire Systems West, Inc. Phone Number:253-833-1248 206 Cony Rd N, Suite C Pacific WA 98047 Address City: State: Zip Code: FI RE S WI055LW 06/16/2023 Contractor's License Number: Expiration: - I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws,rules and regulations of the State of Washington. Applicants Signature Date Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Dale Received WEB Form—130 Page 1 of 1 6/1 GLP I� I ®'®' � � 00 M In In mja Alf off n- hq a hq a hq a I w y 8 p m S p B D C C C x y 'w $ o ap i 3 S h3 r 8 s� 8. 3 I c hq aqc aqc rho N4C) ywlm� a�bb Nq f3 v v v a s s 22 ,( -,r C e J I In ri c c V g I N V N $ ' hqc� Ngc2 a qc3? q q s? _ q?? = a O s A c> a v �- r y r'O + 'O N agC7. 2 �' N Ncl 2; N aqC4 = a C4 2 (+ 2 V ��+�, 2 r • hqc, >> :o > cn 7 vv 7 v I l . . .a A o O C G gig 4 SI��.5 g F 8 Igi $ TH F F F i - .t m I j t o ' gt I W I w �I� 'c gs Nj,9 s4 cn N�� NT ......... _.. ........ -- .__. .. s m, e . (c siwe ck a p � a 8 F_1y8 0 O t0 00 -t m U11 A w N -� gg d 8 cn rn m m = cn z O O ?! 21 I C I d ♦n Q 0 c = c D D 9 O O O N N .Od.. a 0 N N I n A 7 c 8 OO o o C)i y a c N CS3 fA o m m m@ E v v I �fI�2 N o �v o 3 : 3 :OE Q p N O 8g sR p2 4 A A f� gg s�c9jJ. O O O N n 111, W N M C. @ N g � 8 b P ' $ �I' -� J e' C � 'R $8 b ltl 5y • O. rn ? U) N pg 8. I s � rn 3E .. 3$ W Mg3y° b s��xi•,4 a s��ss co 0 b b S�cXfys S`CSs (A D • • • • • • • D W • • • • • • • 4ate • s� s sc • n • n q°teat g4dib/e n q/arch S cSa (D 0 qct e Coin q/S� /a/ar ato 0 0 . m rn • • • . • m gct4ateg4di'non 4 Si9h /nd/c r 0 z � � $ �6 � to a rti � w S� S• (n O G� • • • • • • • • • • • • T,cft/we'q �0 Tr n'�S ry S s qp /n ,...,......., o o. F t ' fly 8 c ? > 2 • • • • • • • x q uaMit Fireq/CoMMpe S79 aka/ar di�ator y m s s s s F I sic - - Tra F�ac �hSin 0Ub/n Bator c �' g � � Tr S h to 9n o g9b €cFg . x1'j -DI • • • • • ns�it 4atio 9ha/r a Si M m a o 0 0 m g o I >g auaei 44bei S/S�/ S4 a/9St rn §ss § mg )C • • • • • • • qct t Tro Sory s perk o o a a a r • • • • • • • r E Sy na/t dti� I Z • z e �/ ry O ar F n Reoa/e e a9net a Cl at 4se sin S to o ryr 9 -1 �a// ators yNer Res St. op e Re V r d 9 • • � t tr S rl'' a I w h o m ou .1 rn Ln A w N lcret'ators fo p i�ar Qoo s ponce po� 8 b 6 b it w I r R r t b-Il b b�bb b.b 666bb b6668b - q/ternate eca%/Fr�. w °° ° e o o e e e° e°° • emww - .. --- !'a --i z� 3� mco Sao �� >0 M-1 M -1c+ vrw Zcrj 0 m:N O-n go Mn pT zT �q p��� mrr �D� �m� / r 0 0 0 Sm tjm Orn rnm �m Dm DA vopeoppm zm re� C° to rn �� �� -XI D(p 't{n 0W' rnrn Z�DZ �n� 0�2 ��3 n m M m rD�l z� rn� Om Zmm nW OcD_n >z� ZO zm D [*1 a G .�, 0 n �m Om ,m �3 �� �3 �X mm 2 M. -4�z Tm vM O 0 Oct�n < vN torn Mtn rntn cz mMWtn AjM{ xm_ yAz m O m D Q -1 M A �� m< m� pAr=D �Dy m�z {M ��f3�o v1 z D q c�`r z`2 zrn �rn tom v_gix cc-M rn tnM0-, <ztn m mm Tm to Mtn torn D-�� ��3 DO- �, w ©. ro F ry 8888�yi�z QCl to torn r-w �� xz ram- v �-ttn Am0 o rn n xr7 Ommc DZ mm 9 - r OTF �F �� tz 3�_ 1 rn DD t�0 rT1�0 000 r M.1 M, 1 D-D .Zl rn::4 cn z a C° r c� mr z m2 cz zD -AMT00 pr mz� �ooz Q. o �8 � �DD� -zi0 to w O tzn =uzi �(zn tn� n� 9v mmmx O� Dp0 0 888 zz� > ��mm� v 01 D mD yD ooz -tnz -1- <c� OtnD mm 'S §1 z00� �O to T D C� rD rr- err �� m0 pz-0 Sz m 10 O ro :r f '�'�_m�t D Z TI V r -1 r r 0 �" c m v y �o vv rzzZ Z z p mZ AD rn0 Dm�Z Mtn �- z " Y- ��"1c��� ZDDD D� r z 2z Z c rtn z �T r_zm0 tnx torn cc0 rao a mmc�vr Orr-I _IC m m mm m D <� mm 3� -I�p > r � � rn�� n��00z �' �� `� n m z� �m _1r5) 8 a Z Zn M Z y� x �; m mZ�tn O� 0 0 ==Rv�m o OmnD D- v z O �1tT1 0 Op mm cm11+� DO �� z v o �+ 8g88 c oz 0D0r rD 0 1 TD z C� �17c m PO 0 _jz MZ 2! ln'D r� S by N m �m OCOr \i jj z= mrpn D D -O-iO�z �jT �I�Tt DA Mym v0 RI > D� ° m Drat � ztnaiD �� 03 mo DF= r(� O �� D >� mg Z Dm�C D mz O�o z 6yz og o m DCVO Zm z Dpp O -i (� zn<A v`L mD �vm ` 'Ocyy ZOvOw GAO v n v-rnm �� tnD <� tn, boa p4 3 3 mm �prn 0 m mm z OmNm r2 Dm 0 C rn C n M N�=z DS �y mZ o m a '� i 7 " f° m D m W v oy O' w rn Cl)m O O ; Or 0 0��� rm Z� am'T O hi A z z ?�- m� z ip D A to _0 OM m { PROJECT: 8171-0946 SMOKEY POINT MOB-FIRE ALARM PLAN DESIGNEF, NO. REVISIONS DATE BY I NO. REVISIONS DATE BY CHK ,Fire Systems West., rj _ CONTRACT NAME CONTRACT WITH: 1 ISSUEDFOR_REVIEW 1 0/1 312 0 21 CO MWC J. DATE: 10113I2021 Smokey Point MOB H&M Electric,Inc. C.OLIVAREZ _ _ 4011 172nd Street NE 918 Cedar Street NICET FAS-II,#1 ._ 206 Frontage Rd.North,Suite C SCALE: 1/8'=1'-0' Arlington,WA 98223 Marysville,WA 98270071 Pacific,WA 98047 - SHEET: FA 01 ON-SITE CONTACT:Josh McCann/360.658-0501/joshm@hmeledric.com i t:(253)833-1248 f(253)735-01132 WA CL#FIRESWI 140B1-WA F,CI,#FIRESWI 055LW FILE:Smokey Point MOB FlreAlarm Drawing.cad DATE:10/14/21 TIME:08:54:55-- X .,,> o II rn i (]k o ( m z y m 0 o I o a o as Cu x� icw I I x x I ;Q I I I I I f I I � I m Cn � I x � x I 9 s D f s ZI v c� v z � I I -I r i r I -n_ I � I TI r x x I 0 n n on ` ° � r V 3NI IHO1bW b 3NI1H0iVN I .�\ m j i 0 n D Zs 7�as �V yrn rn-iTVI -ica+ Amp cN mT < y s m m p mT O tl O� �T OoT zT Tm p0n� mi-T AD� �m� n p (� Sm Om Om rm rm rm yy 3c rn n?m �'zm r04 m DN mtn mtn Ztn zr mF°n�z �!n> low ypm ^` D z r(A W < (A< { C)r C�j n rtn OtCi1 2� �cn D(n o(n mrn ��Dm yns �—Ip ��K m < 1 A O= � D c W O 3 z� m— c� n m 0m zm �m �; �; �� �� - zit T.Z1 m o O �� rn� vg torn Mtn mtn 0 mm�w ��j =mz �mz ? m O m D o < _� m* m� CZ fJpO°D �Dtn m z -<Mo —0 z� crn r r_ o v m Q m rnm �m Mtn <cmil wI of >% { Cn�m D0= Dn= A �z�xmn rn '-Ni m� �� � � (�� i1 pgms �m0 NJoo oD �_� O� O ry mz-�rn nczn Xn� vcz XF �F �� Cr err- r� W-in-1 1 Day cA 0) 4Cn cyl - rn m r Dr for r- zD R1xT0 yD c�0 m�O .Q a cnzzZZZ W a o z Qz Az �y zy �� ��m= 00 mz 0Mw p'mmmx � Z1-�mm0 w D OD D D O� �D- rn(j pz�z -4 {cCM') 0'D r� i d D00�1 �7z to r cr r r Ar pr c 0 z pp s � jT'0 ,=Z�0 rZZZz z T r 1r r 0 mz o.D A Dz �N �� 1nz e �r n'mM�c>vv Z��� —DIC r m =m m s z A�gDo nT Dr mDp� Drzt1 �T� rZ`�p y= zm0t�n �ccp �OO �� � nm �m � g � m Tp* n00 z� rn OrnmD y Z O* om of oZ�' tJ n p z vmmp O $ z�v �y - ' O mD�rmO pcx r r9imp n <-Azm� v�= m� m�< rMT W ;um AnSp � nO rmm 0'CA Zm rn D D D O D -4O y > r�r � pp 0 DT z zvmn oK )O z� zDO nn Zm( mMDmZ0n p tJ m m O0 z mr ym 00 rn Om umi O O ; Or 0 0��� �m zD my rn 0 g z Zzq m� � Z PROJECT. 8171.-0946 SMOKEY POINT MOB-FIRE ALARM PLAN DESIGNER N0. REVISIONS DATE BY CHK NO. REVISIONS DATE BY CHK-T COMRACT NAME: CONTRACT WITH: Ftre Systems West It DATE: 10/13/2021 Smokey Point MOB H&M Eledriq Inc C.OLIVAREZ 1 ISSUED FOR_REVIEW 10/13/2021 CO MWC - a O 172ndStreetNE CedarStreet _ .SCALE: 1/8'=1'-0' Arldinin gton,WA 98223 IMarysville, 206 Flbnt8e Rd.North,Suite C Pacific,WA98047 WA 98270 NICET FAS-II,#153071 -- - - SHEET: FA02 ON-SITE CONTACT:Josh McCann13%65&OW1/joshm@hmelecldc.com � - t(253)833-1248 L(253)735-0113 FILE:Smokey Point MOB Fire Alarm Drawing.cad DATE:10/14/21 TIME:08:33:58- X WA CL#FIRESWI 14OB1 WA ECLO FIRESWI 055LW I I x I x I 0 D \ m NN �. 7 4 d 9NI-1HOiVV4 V 3NIIHO1bW D N r> c m I rn o" m rm� Z O Lz\ H m mnmo �~ Om n rn I'll; m r m 0 I I I I i rn p _ z% --I I � I D I Z m O _ r I O D � I r `n's sus U) -- v --I x ,1 r.' o � U'2iii ^F• N ag ,<C r O I F F E E F F w m D C0 m N v' D )--g 6 22 m 2s 3. ------- m o' D m cn R X Z D � r m -` -ice z� 0n n �W �v Drn m imcn 1cA mrw cN /\J =N O. p� OT pT D-4 vm IJOD' -1C mm' �cn' 0 mm 9T zTI v— z— �D Swn* "' 'm $o* �mw n p p xm MOm Om rm Cm Pm yD c�m (�zln _zrn r�1 C D � rm-m Dw �w « m< Z{ m {Z �!nD �c�w 5prn W r� �< 1� D(n w v w m m z—D z w n m 8 2 _ m n gat m w Ow =(n 0-I D � r Z1<m i � v00 O� D n n m sm �m �m �� v; �� �� �mDrn zT� z?15� Z--n;u m O D r n O� 3 w v' w -1�z gm— a p w O O C(n <w �w _� mw �� CZ mmW(n D�j Sm— D;z m 0 �cS (�� z� Crn rn� Wx> ODw mmz < i 7 y B. m mm Tm zw 5(mn wncmn w= DC < ln* Dpx Dnx (n L o N zz �rlma ( w0 r' �t� 3-4 O� (nz r3 v D3 AAA 'm0 NNN IN)> rn `e =� mac{ �� Of O� DO 0Mmc' c>z '92 ��� Q 0000� — 0 � OF AF vF 0� �� �� mZ' m, y1 Day ��Z Y �vCn (7r— — rn po 0 r r (nr r— C— Zy S?l0 ZD (�O� mTZ (nzzZ zZ W a o c— m— Z mz zz Ov Am-(� v mz— 80 �i DD w w w xw ' (n 1 w-yi 8--" �� mmmS rD S>mz Omv g8 m:m§ Zm rn� A w D OD D Or �� m� pz{z =p {Aw OppDD cgv��m, >OOZZz Z T T Cis � r mr Or ma.. C�wG) inz �Dz Oil r <"='cZiv� ZDDD D� r z -Iz z �m �D m0 DZT0 �w 3— Ccz rr� r _ m xm m - z �m rz (,� wx mcn 0 mmA� ��Tmp pz D cS mc1 cam, <`� m111 3f =1(�nv �D �� 0Dw Lit; p-rz Zn m O Dtn w� p m zr m � tn m z D� �� "Trn TZ�(n v0 O� pS�oZ vD�r rD v OD Z O m �� zvwCMMZ �z x3 �mrA?I Wr 71 z= C A D 0 (�0� .n wm mO m D—� Cn rn n Om O -I mo 1�Am p m D� �Dm r=� O� x Dm r Otncmi�0 D1 c�v zD o �r�� 12v D f7 � y r� A z zvmc w3 �z OK D Zm O ;A O -i rn O Dm�— D rn Z000 G)(n z �O v v n �nr;m �� tnD <-DF o vpm 0 m m-T rC Oz T pTw3 r= Srn nn y �Wm D m 0 m w -wH 1 O w�m� Wrn zD my �. cn O r z Z:q m S -0 z 0 w _� Om W { S (n m PROJECT: 8171-0946 SMOKEY POINT MOB-FIRE ALARM PLAN DESIGNER NO.1 REVISIONS DATE BY CHK NO, REVISIONS DATE BY CHK Fire Systems West In DATE: 10113/2021 CONTRACT NAME. CONTRACT WITH: 1 ISSUED-FOR-REVIEW 10/13/2021 CO MWC Smokey Point MOB H&M Electric,Inc. C.OLIVAREZ NICETFAS-II,#153071 206 Frontage Rd,North,Suite C SCALE: 1/8'=1'•0' 4011 Arlington,WA Mar Cedar Street _ Pacific,WA 98047 Arlington,WA 98223 Marysville,WA 98270 SHEET: FA 03 ON-SITE CONTACT:Josh McCann 1360-658-0501/joshm@hmelectHc.00m t:(253)833-.1248 f(253)735-0113 •FILE:Smokey Point MOB FlreAlarm Drawing DATE:10/14121 TIME:08:40:24•• R WA CL#FIRESWI 140B1-WA F.CL#FIRESWI 055LW DN � _. O 00 li m oN - � J o Z 0 °° 0 D 3 j .. � rn c� O z v O rn �� -.I ..tititititititititit�.itititititititititt�.tititititlititittit�.tititititititititit�.t�. � tIIIIIIIIIIIIIIIIIt�.titit�.tititititititititit�.Iltitititititititit�.�. .tt�.tltltltltltltltltlti�.�.�. .��.titititititit�.I�.�l V 3NIIHOIVVY d 3NIIHOldW O M.0 rn m a � � N m r m ® m Z� 0� Tro Koo A� Dof m-i�l clt -1C4 Arw CN O mT �� z�1 �'� OT zT v� ODn* AST AD* �mtn r O n 2m MOO Orn rm �rn Dm pD �c�rn c_�zm �Zm Co cn rr-� �� 1� Dfp N(i o� mart z Dz yn� �1= ��� n �"' m A m �� z� Al Orn zm Ali �?� pcD2 Yz� z,? zm<<—' m I 00 -cnl D �m 09 �m 0m 0.9 rmn9 0D mm � zv =mZ mz O O� O' to sm— 8888 0 A O o c cn r C Z m po D < -< m O m D A A`d BSc m� 10 pp�_� oD mTz �m0 0 m mm zr.m �m Zvi twittp ln.r�'2 Dp_x Dni cn o yl�z��1m> rn 1 1� m� -1� 9� 0� tna Om-ME D— mm� {mG0 NNN N A A O� 0*2 D Am-1 AZ o000w — 0 F �F AF F °cr= �� rr� 'm 8 - Day ��Z 0-40 Ln 0tt r Or tnr r— C— 2D m2m0 ZD mZ� cnzz— Z tp O z ciZ Az A cmnuzi zN Ov �r"A0 v z vy =SENS � G)DDz 1� cn w to 2tn to � T1 n-I 1� Ammy O� DpG� pm� g888� mm��n p z��m m0 v D OD D Or DD �z �z �00 pp�D s� rg��� T DOOA XZ to r cr r r Ar Om pzyG) m0z �m <nD� So r_ZZZ Z Z r �r r ��— -in- 56 a21 DDD DK T r z �z z �c �m AD m0 r> ZO y= m(n AEG mC) Zrr� _I r rn ern m z AT r cc m"'g �.Dm0OZ D v� r Dai �r2 3� �mvm Drr- �m ��1n g� OmrnD Z> 55 v Z O �m O Opp .T m cmrno p0 �_� z*v gg88 0l vZ 0D�r rD n 1 TD z 0 Ajt m oO zo�z �� A (nmD y� m ��� WO rn n Om O -1 mmo D ��Am �qT AM Dm g S ;ym rp 0A A x Drn S; r 0tnumifJ D� v� S Zn00 Zm Z �� 0 Dm�z D� rT1A mD 0. 00 �fn �0 8 p -p1 0 � onrnm m mD <E, ow wpm n m mT r 1 0z n vmuim r2 Drn m0 m m -I 0 ��r"tn rrn z� t7 o F to O A r z z�A' m� Orn z O 2= Om ao r * A 0) m PROJECT: 8171.0946 SMOKEY POINT MOB-FIRE ALARM PLAN DESIGNER NO. REVISIONS MBYN0. REVISIONS DATE BY CHK FireSysterMWeS.4Ir DATE: 10M312021 'CONTRACT NAME: CONTRACT WITH: ISSUEDFOR_REVIEW Smokey Point MOB H&M Electric,Inc. C,OLIVAREZ -. SCALE: 118'=P-0' 4011 172nd Street NE 918 Cedar Street NICET FAS-II,#1530r1 _.__ 206 Frontage Rd.North,Suite C Arlington,WA98223 Marysville,WA98270 Pacific,WA 98047 SHEET: FA04 ON-SITE CONTACT:Josh McCann l3%656.05011joshm@hmeledricoom m,, ((�� t:(253)1g33-1248 E(253)735-0113 FILE:Smokey Point MOB Fire Alarm Drawing DATE:10/14121 TIME:08:43:46-- R �' Q� --� WA CL#FIRESWI 140B1-WA ECLM FIRESW!0551,W Q V�INIIHOIVW V 3NIIHOlVW D. r> m� rnrn -, rm t (T1 o� _ % �� m � o m/ o ! N o� 10 i i i 0 7 O I D n 10 Z 0 \m� O G, mow\ v_ —I N -i� z� KE; -nm ern V D m m-im Cn -1cA -orm W cN D N O� O D v z� 1 mm �m Oz� DTI m;Uporn zm m� p2n rn-m m8* (� O O xm nrn Orn In rm rm Dm DD gv�m nmm �zm Dq z m mto men en Zr vt z D �t7y Dom C u 1 r< �� -I< Dcn cn v(n mm z-Dz cnnD en « tn� (fir -i r mix D x" m m D� 5- rn� Om zm `gym Or 0cDn Dz� v00 0m4� c /-� oo O�-m z s zT� zm- m O " �� �� m� tne�n �N mein �D rmnmW� DM-< mm- DMZ z m O m D Q < �`� BSc m� z fJp�D �Dtn mrnz 1mV7 � fl8a N z ✓? C7 m mm T.m (A -DG fmn chi)cmi) 1nx CC M Op- —I N <z(n Cf) t �zgma)> (n en en ren enz Dry � N�3 DOS De�x �p3 vX m i-A m-i -ice �� 0 SO Ogms >- mm� {rn0 m Ij q oo4�r� 0000� — (' XF of KF �� Wzin-mi n-�i any °cz " rnvw tnZ �rn m c0'— rn� z m2 cz zD m2�10 zD mz� �O� enzz- ZG) to z Oz �z cn [nen zen O� �mT,0 pr z en f ° J888 ='�zgm�p O-DI-_DID �0 � W � � x� �I D 'tD n> co XmmD O� DpG7 pOm� DOOM �Z 0� Dr �r- p� �� pz�0 mOz ��m (pnD`c -v v rZZZ Z z v m2 �D m0 �'-.Iz �)en S� �nz D>MMczi�v ZDDDD� T r z -iz z c rm C:zM �-I w'm<X G) Orr �j Frrl m mm rn D mS� Drn _3T r��0 -�iD z� ccG) fr m m�0 -nm00z ,"� r < m -cnv Dr �m C)D m' SD n (1rZ Zn m n Dcn (n� �� 0 m zr m =Irv) 4 z T=' OmmDD v Z p �m O O� "T mm crnm6 pn �� O�v . fl8-8fl"o oz �y0rry _I T-.D z (� mR .Tl p� z0r) D� x--� Z�)- g m Cr ITI (� GOS p mmo D OD -10mm O n �m �D� a m D n m f1'1 C r x o tx 4 �Dm r > OS x rn y1 �x r zOlncmnD D b �p ZD O� n O Dr0 Zm O �; O -1 rn K O Dm�c m3 �z •", ? Z00 0G7 z DO v 0 1 zn<m vg F^� "$" <a DeA�„T , pv00 O m� e m O O pT�; �-� 20 <� -« m 4,,=' D m O < � m m U)) --I y mp0-iz 0 �� mD oc "" x m Cl)m O O Q Or O n<L-� m--rn z� o * A -Tl0 m - z z=0 mOm m O 0 O r m Cl) m PROJECT: 8171-0946 SMOKEY POINT MOB-FIRE ALARM PLAN DESIGNER N0. REVISIONS DATE BY CHK NO.i REVISIONS DATE BY CHK DATE: 1011312021 CONTRACT NAME: CONTRACTWITH: 1 ISSUED FOR_REVIEW 10/132021 CO MWC . Te SyStenm West, In Smokey Point MOB - H8M Electric,Ina C.OLIVAREZ 4011 172nd Street NE 918 Cedar Street - - - -- - ----------- ----- SCALE: 1I8'=1'-0' Arlington,WA 98223 Marysville,WA 98270 NICET FASII,#153071 206 Frontage Rd.North,Suite C — Pacifiq WA 98047 SHEET: FA05 ON-SITE CONTACT:Josh McCann 1360-656-0501/Ioshm@hmeledric.00m t>(253)833-1248 f.(253)735-0113 FILE:Smokey Point MOB Fire Alarm Drawing DATE:10/1421 TIME:08:46:49-- X -' WA CLM FIRESWI 140B1 WA ECLtt FIRESWI 055LW CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 4011 172ND ST NE Permit#:4199 Parcel#: 31052100306500 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:New Fire Alarm Valuation: 11500.00 OWNER APPLICANT CONTRACTOR MARKDEV SMOKEY POINT LLC Fire Systems West,Inc. Fire Systems West 105 TALLAPOOSA ST STE 307 206 Frontage Rd.N. Ste.C 206 Frontage Rd.N.Ste C MONTEGOMERY,AL 36104 Pacific,WA 98047 Pacific,WA 98047 253-833-1248 206-833-1248 LIC:FTRESWI055LW EXP:06/16/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I I O/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. i a PrW Name J Date Released By Datc CONDITIONS 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET II certification upon request.2.Battery load test required, switch distributed power module to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power.3.Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the City of Arlington stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2)5.The record of completion form shall be submitted prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/16/2021 FACP/Transmitter $200.00 11/16/2021 Fire Alarm System Permit $350.00 11/16/2021 Process]ng/Technology Fee $25.00 11/16/2021 Fire System Plan Review $203.35 Total Due: $778.35 Total Payment: $778.35 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 4011 172ND ST NE Permit#: 4199 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052100306500 DATE OF ISSUANCE. Scope of Work:New Fire Alarm Valuation: 11500.00 OWNER APPLICANT CONTRACTOR MARKDEV SMOKEY POINT LLC Fire Systems West,Inc. Fire Systems West 105 TALLAPOOSA ST STE 307 206 Frontage Rd.N. Ste.C 206 Frontage Rd.N. Ste C MONTEGOMERY,AL 36104 Pacific,WA 98047 Pacific,WA 98047 253-833-1248 206-833-1248 LIC:FIRESWI055LW EXP:06/16/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 44Z Signature Print Name Date Released By Date CONDITIONS 1.Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request.2.Battery load test required, switch distributed power module to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the City of Arlington stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2)5.The record of completion form shall be submitted prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/16/2021 FACP/Transmitter $200.00 11/16/2021 Fire Alarm System Permit $350.00 11/16/2021 Processing/Technology Fee $25.00 11/16/2021 Fire System Plan Review $203.35 Total Due: $778.35 Total Payment: $778.35 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Date: 04/17/2026 Permit#: 4199 Perm Date: 10/20/2021 Review Date: 10/20/2021 Perm Type: FIRE ALARM Review Type: FIRE ALARM Target Date: 11/24/2021 Scheduled Time 00:00 Com pleted Date: Description: Fire alarm plans with AES radio Review Status: Assigned To: FIRE Tim eIn: 15:30 Time O it: 17:00 H curs: 1.5 Property Information Parcel#: 31052100306500 MA RKDEV SMOKEY POINT LLC MARKDEV SMOKEY POINT LLC 1 05 TALLAPOOSA ST STE 307 4011 172ND ST NE MO NTEGOMERY,AL 36104 Zoning: 910 UNDEVELOPED (VACANT) LANDLot:ABlock: Permit#: 4199 Permit Date: 10/20/21 Permit Type: FIRE ALARM Project Nam e Sm(key Point Medical Office Applicant Nam a Fire System sWest, Inc. Applicant Address: 206 Frontage Rd. N. Ste. C Applicant, City, State, Zip: Pacific, WA98047 Contact: Cam Iyn Olivarez Phone: 253-833-1248 Em al: cam Fno@firesystem avest.com Scope of Work: New Fire Alarm Valuation: 11500.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/19/2021 Permit Expires: 05/18/2022 Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address L egal Description O wrier Nam e Cvner Phone Zoning BSP#418 REC AFN MARKDEV 910 31052100306500 4 011 172ND ST NE 201808215006&AMD BSP SM OKEY POINT UNDEVELOPED REC AFN 201811065001 LLC (VACANT)LAND Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# Fire Systema 206 Frontage Rd. CONSTRUCTION West M tt Carlm ai 2 06-833-1248 UBI 600 602 737 N.Ste C CONTRACTOR Fire Systema,West M tt Carlm ai 2 06-833-1248 206 Frontage Rd. CONSTRUCTION Labor a N.Ste C CONTRACTOR Industri nd es FIRESWI055LW Plan Reviews Date R eview Type D escription A ssigned To R eview Status 10/20/2021 F IRE ALARMB UILDING 10/20/2021 F IRE ALARM F ire alarm plans with AES radio F IRE Fees Fee D escription N otes A m cant FACP/Transmitter-New $200.00 Fire Alarm System Perm i N FPA 72- 105.7.3 $350.00 Processing/Technology $25.00 Fire System Plan Review T able 4-1 $203.35 Credit Card Service $23.35 Total $801.70 Attached Letters Date Letter D escription 11/16/2021 Building Permt Paym arts Date Paid By D escription P aym art Type A cccptcd By A m cant 11/16/2021 James S Blackburn 8 9788328 $778.35 11/16/2021 89788328 A m cresia Lawlis $23.35 O itstanding Balance $0.00 Notes Date Note C reated By: 02/14/2022 Perm i cancelled as per applicant's request. R aelynn Jones 10/20/2021 Plan Review Fees calculated on the application are incorrect. R aelynn Jones Uploaded Files Date File Nam e 11/19/2021 10140819-4199 Issued Perm t.pdf 10/20/2021 9941616-10-19 MOB Cut Sheets.pdf 10/20/2021 9941614-10-19 MOB Fire Alarm pdf 10/20/2021 9941615-10-19 MOB Plans.pdf