Loading...
HomeMy WebLinkAbout17315 81ST DR NE_BLD2299_2026 NOTICE TO PERMITEE AND/OR OWNER ?j•W Cl PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY XAPPROVED PERMIT#: LOT#: DATE: , JOB ADDRESS: 112,lg TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. Cl CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE BUILDING DEPT. , v� 0 PLANNING DEPT. CITY OF ARLINGTON CITY OF ARLINGTON 238 N. OLYMPIC AVE- ARLINGTON,WA. 98223 co PHONE; (360)403-3551 BUILDING PERMIT Address:17315 81st Dr SE Permit#:2299 Parcel#:01040900001700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PEPIN BRUCE A&TERESA M Name:Andgar Mechanical LLC Name:Andgar Corporation Address: 17315 81 STAVE NE Address:6920 Salashan Pkwy A-102 Address:6920 Salashan Parkway City,State Zip:ARLINGTON,WA 98223-9817 City,State Zip:Ferndale,WA 98248 City,State Zip:Ferdale,WA 98248 Phone: Phone:360-366-9900 Phone:360-366-9900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Andgar Corporation Name: Address:6920 Salashan Pkwy Address: City,State,Zip:Ferndale,WA 98248 City,State,Zip: Phone:360-366-9900 Phone: LIC#:ANDGAC"19102 EXP: 7/11/2019 L1C#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCl l0/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlin, n ist be reported on our sales tax return onn and coded City of Arlington#3101. // ' Marla Raske 12/03/2018 t:c Signature Print Name Date Rcl as d 13y Date 1 CONDITIONS I( Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/30/2018 Mechanical Fee(Enter Fixture Fee) $25.00 11/30/2018 Mechanical Permit Base Fee $25.00 11/30/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,'I'ype of Inspection being requested,and whether you prefer morning or afternoon ii; M GiTY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17315 81st Dr SE Permit#:2299 Parcel#:01040900001700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PEPIN BRUCE A&TERESA M Name:Andgar Mechanical LLC Name:Andgar Corporation Address: 17315 81 ST AVE NE Address:6920 Salashan Pkwy A-102 Address:6920 Salashan Parkway City,State Zip:ARLINGTON,WA 98223-9817 City,State Zip:Ferndale,WA 98248 City,State Zip:Ferdale,WA 98248 Phone: Phone:360-366-9900 Phone:360-366-9900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Andgar Corporation Name: Address:6920 Salashan Pkwy Address: City,State,Zip:Ferndale,WA 98248 City,State,Zip: Phone:360-366-9900 Phone: LIC#:ANDGAC*19102 EXP: 7/11/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arling m on ist be reported on our sales tax return or and coded City of Arlington#3101. /J Signature Print Name Date Re l as d By Date CONDITIONS (` Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/30/2018 Mechanical Fee(Enter Fixture Fee) $25.00 11/30/2018 Mechanical Permit Base Fee $25.00 11/30/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon S �� r ;�, i Permit Information Date 11/30/2018 Permit Number 2299 Project Name Andgar 81st Dr SE Applicant Name Andgar Mechanical LLC Applicant Address 6920 Salashan Pkwy A-102 City,State,Zip Ferndale,WA 98248 Contact Phone 360-366-9900 Email corporate@andgar.com Permit Type Residential Mechanical Site Address 17315 81st Dr SE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use Replace gas water heater Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 01040900001700 117315 81ST DR NE PEPIN BRUCE A&TERESA M 111 Single Family Residence-Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Andgar Corporation lRob Vasdain 360-366-9900 .,orporate@andgar.com CONTRACTOR _abor&Industries 4NDGAC*19102 Fees Fee Description Notes Amount Mechanical Fee Enter Fixture Fee 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $75.00 Uploaded Files Upload File Date File Uploaded B 11/30/2018 11:41:24 AM 12299 Specs.pdf Jones, Raelynn { 11/30/2018 11:40:22 AM 2299 Application.pdf Jones, Raelynn }( � 1 RESIDENTIAL MECHANICAL w PERMIT APPLICATION �N Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:17315 81st Dr SE Arlington, WA 98223 Project Description:Replace Tankless Natural Gas Water Heater Owner: Teresa Pepin Address: 17315 81st Dr SE City:Arlington StateWA Zip Code: 98223 Phone: 425-238-2579 Email:corporate@andgar.com Applicant: Andgar Mechanical LLC Address: 6920 Salashan Pkwy A-102 City: Ferndale State WA Zip Code: 98248 Phone: 360-366-9900 Email: corporate@andgar.com CONTRACTOR INFORMATION Contractor Name:Andgar Mechanical LLC Address:6920 Salashan Pkwy A-102 City: Ferndale State.WA Zip Code: 98248 License Number:ANDGAML825NE Expiration: 07/31/2019 Phone:360-366-990 Email:corporate@andgar.com STAFF USE Ozz Permit#: Accepted by: Date: Received 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE ❑ Heat Pump Model # AFUE HSPE ❑ AC. Unit Model #_ SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ Tankless ❑ Gas Piping ❑ Solid-Fuel Appliance 16 Other%AMt-=r Gas Piping Information Not Applicable: 16 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance.- Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve 1is required within 6 feet of all appliances f it t��i C%`:UrJ C. Applicant Signature: Date: 11/30/2018 Applicant Printed Name: Marla J Raske I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Naviem NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater •Certified design according to ANSI Z21.10.3-CSA 4.3-2015 �r •�• standards for both indoor or outdoor installations(with A optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to a length of 24It* (*see Installation Manual For additional information) •Compatible with 2"PVC vent up to 60 ft**and 150 ft** L7 using 3"PVC vent("with no elbows) •Gas Input Ranges NPE-150-120,000 to 18,000 BTUh Diagnostics —Up NPE-180-150,000 to 15,000 BTUh NPE-210-180,000 to 19,900 BTUh Information tr Down NPE-240-199,900 to 19,900 BTUh Reset Power ON/OFF •Hot Water Flow Rate Capacity(*based an 35OF temperature rise) NPE-150-6.8 GPM NPE-180-8.4 GPM Built-In Control Panel NPE-210-10.1 GPM 1 ser NPE-240-11.2 GPM with Diagnostics Sleek Design-Compatible with •Dual Primary and Secondary Stainless Steel Heat 2"PVC Vent and 1/2"Gas Pipe Exchangers for optimum efficiency and durability •Built-in Control Panel-allows adjustment of temperature settings and displays the operating status and error codes 1 Indoor and Outdoor •QOO MOOO NNOW Technology-"A"models come included with Venting Options built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide I"intake Cap maximum comfort rcoudi�9- 2"Pipe- •INTELLIGENT Preheating recognizes hot water usage patterns Outdoor veracap— to intelligently provide hot water when needed(optional for"s"models) •Temperature Options -available temperature settings for ,Ar" Residential applications range from 98"F up to 140'F with high temperature Commercial mode capable of up to 182°F •Ready-Link Cascade Compatible for up to 16 units for increased hot water production Non-Direct Vent(Indoor) Non-Direct Vent(Outdoor) •Common Vent Compatible-allows for cascade systems to use a Direct vent(Indoor) single exhaust and/or intake pipe for up to 8 units with the use of the Common Vent Backflow Damper Collar Kit(#30014367A) •Compatible with NavlLnk-Wi-Fi Control(uPBCM-As-001) Q ES`O4 •Freeze Protection-maintains normal operation during freezing ambient temperatures down to-5 F(standard on all models) cyrlf�oa ctonriE� •Uniform Energy Factor Ratings for NG and LP units NPE-180A/210A/240A-0.96 UEF (0.97 EF for Canada) A ILJDF NPE-150S-0.96 UEF (0.97 EF for Canada) NPE-180S/21OS/240S-0.97 UEF (0.99 EF for Canada) •Compatible with Natural Gas(NG)and Propane(LPG)*** (" requires installation of included Field Conversion Kit by a qualified gas servicer) Job Name: _ •Approved for Installations on Mobile/Manufactured Homes Location: •Certified by CSA,NSF 5,AHRI,AB19S3 CA Low Lead,SCAQMD Engineer. (Rule 1146.2 Type 1-Complies with 14 ng/)or20 ppm NOx @ 3%02) Wholesaler. •15-Year Heat Exchanger and 5-Year Parts Warranty(Residential)**** Contractor., 8-Year Heat Exchanger and 5-Year Parts Warranty(Commercial)**** Model No.. (****see Navlen Limited Warranty) Submitted to: •Optional accessories are available(see below) o Remote Controller Plumb Easy Valve Set(3/4") Condensate Neutralizer Ready-Link 3"Vent Termination NR-20DU (30009323A-Lead Free) (GXXX001322-Single Unit) Communication Cable Outdoor Vent) External Pump Wire Cw and Wag Flanges (30009757A) (30012581 A-for Pipe Cover) (GXXX001324-6pto6 Units) (GXXx000546) (30010604A) (GXXX001319) (GXXX001325-Up to 16 Units) C� ?3L�5 -n-ci 9 s Naviem NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater Dimensions Specifications Item NPE-1505 NPE-180A I NPE-1805 NPE-210A i NPE-2105 NPE-240A I NPE-2405 b Heat Natural Gas 18,000- 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H u'aarnU 143'[36M"M a Capacity 120,000 € (Input) Propane Gas BTU/H 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H r y/ Efficiency UEF(for NG&LP) 0.96 0.96 0.97 0.96 0.97 0.96 0.97 Ratings EF(Canada)(for NGatP) 0.97 0.97 0.99 0.97 0.99 0.97 0.99 +rmsa.e e-marr. 35"F(19"C)rem Rise 6.8 GPM 8A GPM(32 L/m) 10.1 GPM(38 Urn) 11.2 GPM(42 L/m) p (26 L/m) Flow Rate 45°F(25'QTemp Rise 53 GPM 6.5 GPM(25 L/m) 7.8 GPM(30 Um) 8.7 GPM(33 Um) Connection Size (DHW) (20 U2) Q Air Intake m Z" 67°F(36°C)Temp Rise 3.2 GPM 4.3 GPM 4.2 GPM 5.0 GPM 5.2 GPM 5.6 GPM 5.7 GPM ©Frhaust Gas vent ID J" (12 Urn) 06 Urn) 1 (16 L/m) 09 L/m) (20 L/m) (21 L/m) (22 Um) FIR RFN Dimensions 17 3"(W)x 27.4"(H)x 13.2"(D) Weight 55lbs 75lbs 67lbs 82lbs 75lbs 82lbs 75lbs (25kg) (34kg) (30kg) (37 kg) (34kg) (37 kg) (34kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI >: Natural Gas Supply Pressure 3.5 in WC-1 0.5 in WC (from source) Propane Gas Supply Pressure 8 in WC-13in WC (from source) Natural Gas Manifold Pressure -0.04 in WC- -0.04 in WC--0.84 in WC -0.05 in WC--0.36 in WC -0.05 in WC--0.58 in WC (min-max) -0.38 in WC Propane Gas Manifold Pressure -0.04 in WC- US in WC--0.50 in WC -0.10 in WC--0.66 in WC -0.10 in WC--0.78 in WC (min-max) -0.42 in WC Minimum Flow Rate 0.5 GPM(1.9 Um),<0.01 GPM(0.04 Urn)option for"A"models* _ Cold Water Inlet 3/4 in NPT ell �c Connection Sizes Hot Water Outlet 3/4 in NPT • •�- Gas Inlet 3/4 in NPT V i Main Supply 120V AC,60Hz Power Supply Maximum Power 20OW(max 2A),350W(max 4A)with external pump connected ti F Consumption Casing Cold Rolled Carbon Steel Lil Materials Heat Exchangers Primary Heat Exchanger:Stainless Steel 60,n)0 I altm'mi Secondary Heat Exchanger:Stainless Steel 2"or 3"PVC,CPVC,Polypropylene Connection Size Exhaust 2"or 3"Special Gas Vent Type BH(Class II,A/B/C) 0 Hot Water Outlet CD 3/4" O Recirculation Inlet" tp 3/4• Venting Intake 2"or 3"PVC,CPVC,Polypropylene Cold Waterinle[ m3/4" 2"or 3"Special Gas Vent Type BH(Class II,A/B/C) © O Gas Inlet 03/4" _ Vent Clearances 0"to combustibles 0 ron cnsara out ler m 1/�" Safety Flame Rod,APS,Ignition Operation Detector,Water Temperature High Limit Switch,Exhaust Temperature High Limit Sensor, Wmod,lsony Devices Power Surge Fuse *Available for'A"models configured in an optional ComfortFlow recirculation mode.Additional energy use will occur when using recirculation. Gas fired,tankless,condensing,wall-mounted water heater(s)shall be direct vent NPE Series models as manufactured by Navien,Inc.and are certified by CSA Group to the latest edition ofANSI standard Z21.10.31CSA 4.3.Water heater(s)shall have a 15 year limited Heat Exchanger warranty and 5-year limited Parts warranty(8 year Heat Exchanger and 5-year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is installed.Water heater(s)shall have a nominal flow rate capacity of GPM/GPH at °F rise with rated input of BTU/hr.Water heater(s)shall be vented with 2"PVC/CPVC vent pipe at a distance not to exceed 60'(or equivalent)with each elbow equal to 8'of pipe length or 3"PVC/CPVC ventpipe at a distance of150'(or equivalent)with each elbow equal to S'of pipe length.Water heaters)is rated for 150 PSI working water pressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WCfor natural gas and 8.0"to 13.0"WCfor propane.Unit(s)shall have a steel case,dual stainless steel heat exchangers,eco premixed burner, negative pressure gas valve,dual venturi,3/4"inlet gas connection,3/4"brass inlet/outlet water connections,water holding capacity of 0.6gallons for the NPE-1505,1.0 gallon for the NPE-180A model(0.7gallonsfor NPE-1805 model),1.2 gallons for the NPE-210A/NPE-240A models(0.7 and 0.9 gallons for NPE-2105 and NPE-2405 models respectively),and a condensate collector.The NPE-1505 model weighs SS Ibs the NPE-180A model weighs 75lbs(NPE-1805 weighs 67lbs),and the NPE-210A/NPE-240A models weigh 82 lbs(NPE-2105 and NPE-2405 weigh 75lbs).Unit(s)shall include features such as an adjustment for installations at high elevation,temperature lockout and temperature optionsfrom 98-120°Fin 1°Fintervals and 125-140°Fin SoFintervals.The unit(s)shall include additional temperature options of150-1807in 10°Fintervals, and 182°F for high temperature commercial applications.All NPE'A"models shall include an internal circulation pump and O.Sgallon buffer tank.The water heater(s)shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors sensing and controlling flow rate to set point temperature with airfuel ratio controls in order to maintain thermal combustion efficiency.Unit(s)shall include safety features such as flame sensor system,high limitsensors,overheat prevention device,freeze protection mode,and fan motor rotation detector.Multi-system(cascade)applications that require 2 to 16 units shall be installed by connecting the units using cable-only connections(Ready-Link).Cascade systems can be common vented with up to 8 units when a Common Vent Backflow Damper Collar Kit is installed.The water heater(s)exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed by SCAQMD rule 1146.2(Type 1)for Low NOx that complies with 14 ng/f or 20 ppm NOx requirements @ 3%02. "Navien reserves the right to change specifications at any time without prior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.Navien.com Rev.11/16 Search L&I Laborki Safety&Health 0 Claims&Insurance 13 Workplace Rights 0 Trades&Licensing Washington State Department of " Labor & Industries ANDGAR CORPORATION Owner or tradesperson PO BOX 2708 FERNDALE,WA 98248 Principals 360-366-9900 VAN LOO,GARY J,PRESIDENT WHATCOM County • VanLoo,Bryan Jay,VICE PRESIDENT • Smith,Aaron Jay,VICE PRESIDENT • Kunzman,Todd Andrew,VICE PRESIDENT ■ MELLEMA,ANDREW,SECRETARY Doing business as ANDGAR CORPORATION WA UBI No. Business type 600100 192 Corporation Governing persons ANDY MELLEMA GARY VAN LOO; TODD KUNZMAN; AARON SMITH; BRYAN VAN LOO; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ANDGAC"19102 Effective—expiration 09/22/1981—07/11/2019 Bond Employers Mutual Casualty Co $12,000.00 Bond account no. S416980 Received by L&I Effective date 05/13/2014 07111/2014 Expiration date Until Canceled Bond history Insurance American Guarantee&Liability $1,000,000.00 Policy no. GLA378496004 Received by L&I Effective date 03/28/2018 04/01/2018 Expiration date 04/01/2019 Insurance history Savings ........... .... No savings accounts during the previous 6 year period. Lawsults against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infaction no. PBATI01050 Satisfied Issue date RCW/WAC 05/29/2014 18.106.020 Violation city Violation amount FERNDALE $250.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required.Plumber trainee, Matthew Hager,performed plumbing installation work when not supervised by a journeyman plumber as required,at the above commercial project. Infraction no. PBATI01051 Satisfied Issue date RCW/WAC 05/29/2014 18.106.020 Violation city Violation amount FERNDALE $250.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision-as-required:Plumber-tratnee, -- Jared Smith,performed plumbing installation work when not supervised by a journeyman plumber as required,at the above commercial project. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 336,680-00 Doing business as ANDGAR CORPORATION Estimated workers reported Quarter 3 of Year 2018"Greater than 100 Workers" L&I account contact T5/MELISSA VEST(360)902-5613-Email:VESM235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. A _ Contractors not allowed to bid No debarments have been issued against this 'tractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/06/2015 Violations Inspection no. 317936002 Location 4051 Meridian St Bellingham,WA 98226 AM-0 W Washington" improveHelp us M I y�Nl NOTICE TO PERMITEE AND/OR OWNER �7 0 ❑ PARTIAL APPROVAL Cl CORRECTIONS REQUIRED ❑ DO NOT OCCUPY XAPPROVED PERMIT#: ` G1 LOT#: JOB ADDRESS: TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION k2 THE ACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE ~ XBUILDING DEPT. 0 PLANNING DEPT. CITY OF ARLINGTON RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 17315 81st Dr SE Arlington, WA 98223 Project Description:Replace Tankless Natural Gas Water Heater Owner: Teresa Pepin Address. 17315 81st Dr SE City. Arlington State.WA Zip Code: 98223 Phone. 425-238-2579 Email:corporate@andgar.com Applicant: Andgar Mechanical LLC Address: 6920 Salashan Pkwy A-102 City. Ferndale State.WA Zip Code: 98248 Phone. 360-366-9900 Email. corporate@andgar.com CONTRACTOR INFORMATION Contractor Name:Andgar Mechanical LLC Address: 6920 Salashan Pkwy A-102 City. Ferndale State.WA Zip Code: 98248 License Number.ANDGAML825NE Expiration: 07/31/2019 Phone: 360-366-990 Email:corporate@andgar.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ Tankless ❑ Gas Piping ❑ Solid-Fuel Appliance Other%AlMtor Gas Piping Information Not Applicable: ll Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances LOW Applicant Signature: d5a513be"a92O�db81'b61e6' Date: 11/30/2018 Applicant Printed Name: Marla J Raske I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17315 81st Dr SE Permit#:2299 Parcel#:01040900001700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PEPIN BRUCE A&TERESA M Name:Andgar Mechanical LLC Name:Andgar Corporation Address: 17315 81 ST AVE NE Address:6920 Salashan Pkwy A-102 Address:6920 Salashan Parkway City,State Zip:ARLINGTON,WA 98223-9817 City,State Zip:Ferndale,WA 98248 City,State Zip:Ferdale,WA 98248 Phone: Phone:360-366-9900 Phone:360-366-9900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Andgar Corporation Name: Address:6920 Salashan Pkwy Address: City,State,Zip:Ferndale,WA 98248 City,State,Zip: Phone:360-366-9900 Phone: LIC#:ANDGAC*19102 EXP: 7/11/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCI I0. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington i ist be reported on our sales tax return orm and coded Ci-ICU" of Arlington#3101. 1�1 la 12 Marla Raske 12/03/2018 Signature Print Name Date Re las d By Date CONDITIONS / I Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/30/2018 Mechanical Fee(Enter Fixture Fee) $25.00 11/30/2018 Mechanical Permit Base Fee $25.00 11/30/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon NavieN NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater •Certified design according to ANSI Z21.10.3-CSA 4.3-2015 ewr �• standards for both indoor or outdoor installations(with t optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to a length of 24 ft* (*see Installation Manual for additional information) •Compatible with 2"PVC vent up to 60 ft**and 150 ft** using 3"PVC vent(**with no elbows) •Gas Input Ranges NPE-150-120,000 to 18,000 BTUh obgnostin Up NPE-180-150,000 to 15,000 BTUh NPE-210-180,000 to 19,900 BTUh Information O Down NPE-240-199,900 to 19,900 BTUh Reset —Power 01,11011 •Hot Water Flow Rate Capacity(*based on 35OF temperature rise) NPE-150-6.8 GPM NPE-180-8.4 GPM Built-In Control Panel NPE-210-10.1 GPM NPE-240-11.2 GPM with Diagnostics Sleek Design-Compatible with •Dual Primary and Secondary Stainless Steel Heat 2"PVC Vent and 112"Gas Pipe Exchangers for optimum efficiency and durability •Built-in Control Panel-allows adjustment of temperature settings and displays the operating status and error codes r Indoor and Outdoor •G guilOOI NiclW Technology-"A"models come included with � Venting Options built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide z Imake cap_ maximum comfort z toupling- 2'Plpe •INTELLIGENT Preheating-recognizes hot water usage patterns oeu^door to intelligently provide hot water when needed(optional for^s'models) •Temperature Options -available temperature settings for Residential applications range from 98"17 up to 140°F with high temperature Commercial mode capable of up to 182"F •Ready-Link Cascade Compatible for up to 16 units for increased hot water production Non-Direct Vent(Indoor) Non-Direct Vent(Outdoor) •Common Vent Compatible-allows for cascade systems to use a Direct Vent(Indoor) single exhaust and/or intake pipe for up to 8 units with the use of the Common Vent Backflow Damper Collar Kit(n30014367A) •Compatible with NavILnk-Wi-Fi Control(sPBCM-As-001) KA o`S'cy •Freeze Protection-maintains normal operation during freezing ambient temperatures down to-5°F(standard on all models) �Fq�r o. °mun° •Uniform Energy Factor Ratings for NG and LP units NPE-1BOA/21OA/240A-0.96 UEF (0.97 EF for Canada) A ILJDFCERTIFIED NPE-150S-0.96 UEF (0.97 EF for Canada) NPE-18OS/21OS/240S-0.97 UEF (0.99 EF for Canada) •Compatible with Natural Gas(NG)and Propane(LPG)*** (**'requires installation of included Field Conversion Kit by a qualified gas servicer) Job Name: •Approved for Installations on Mobile/Manufactured Homes Location: •Certified by CSA,NSF 5,AHRI,AB1953 CA Low Lead,SCAQMD Engineer: (Rule 1146.2 Type 1-Complies with 14 ng/J or 20 ppm NOx @ 3%02) Wholesaler. •15-Year Heat Exchanger and 5-Year Parts Warranty(Residential)**** Contractor., 8-Year Heat Exchanger and 5-Year Parts Warranty(Commercial)**** Model No.: (****see Navien Limited Warranty) Submitted to: •Optional accessories are available(see below) Vim Condensate Neutralizer Remote Controller Plumb Ea Valve Set(3/4°) Ready-Link 3•VxttTermlrtNbott NR-20DU (30009323A-Lead Free) (GXXX00(GX%X001322UptoeUnit) Outdoor Vent Kit External Pump Wire 1324- pto6Units) Communication Cable (30010604A) (GXXX001319) Caps and Wall Flanges (30009757A) (30012581 A-for Pipe Cover) (GXXX001325-Up to 16 Units) (GXXX000546) (GXXX3873B) iroNaviem NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater Dimensions Specifications Item NPE-1505 I NPE-180A J NPE-180S NPE-210A I NPE-210S NPE-240A I NPE-2405 iru�o farOV-0 Heat Natural Gas 18,000- 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H Capacity 120,000 b (Input) Propane Gas BTU/H 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H '^ Efficiency LIEF(for NG a LP) 0.96 0.96 0.97 0.96 10.97 0.96 1 0.97 Ratings EF(Canada)(for NG&P) 0.97 0.97 0.99 0.97 10.99 0.97 1 0.99 u nsw ero r.o 35°F(19°C)Temp Rise 6.8 GPM(26 Urn) BAGPM(32 Urn) 10.1 GPM(38 m) 11.2 GPM(42 Urn) Flow Rate 45°F(25°C)Temp Rise 5.3 GPM 6.5 GPM(25 Lim) 7.8 GPM(30 Um) 8.7 GPM(33 Urn) Connection Size (DHW) (20 Uni 0 Air Intake m 2" 67°F(36°C)Temp Rise 3.2 GPM 4.3 GPM 4.2 GPM 5.0 GPM 5.2 GPM 5.6 GPM 5.7 GPM ©Exhaust Gas vent m2^ (12 L/m) 06 Urn) 1 (16 L/m) 0 L/m) (20 Um) (21 Um) (22 Urn) S_ Dimensions 17.3"(W)x 27.4"(H)x 13.2"(D) Weight 55lbs 75lbs 67lbs 82lbs 75lbs 82lbs 75lbs (25kg) (34kg) (30kg) (37 kg) (34kg) (37 kg) (34kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI Natural Gas Supply Pressure 3.5 in WC-10.5 in WC (from source) Propane Gas Supply Pressure 8 in WC-13in WC (from source) Natural Gas Manifold Pressure -0.04 in WC- -0.04 in WC--0.84 in WC -0.05 in WC--0.36 in WC -0.05 in WC--0.58 in WC (min-max) -0.38 in WC Propane Gas Manifold Pressure -0.04 in WC- -0.05 in WC--0.50 in WC -0.10 in WC--0.66 in WC -0.10 in WC--0.78 in WC (min-max) -0.42 in WC Minimum Flow Rate 0.5 GPM 0.9 Urn),<0.01 GPM(0.04 L/m)option for"A"models* _ Cold Water Inlet 3/4 in NPT Connection Sizes Hot Water Outlet 3/4 in NPT •�- Gas Inlet 3/4 in NPT Main Supply 120V AC,60Hz Power Supply Maximum Power Consumption 20OW(max 2A),35OW(max 4A)with external pump connected � Casing Cold Rolled Carbon Steel Materials Primary Heat Exchanger:Stainless Steel rr �c. MY— Heat Exchangers Secondary Heat Exchanger:Stainless Steel 2"or 3"PVC,CPVC,Polypropylene Connection Size Exhaust 2"or 3"Special Gas Vent Type BH(Class II,A/B/C) ®Hot Water Outlet m3/4" Venting 2"or 3"PVC,CPVC,Polypropylene Q ColRecd Water Inlet tD 3/4' Intake 2"or 3"Special Gas Vent Type BH(Class II,A/B/C) •Cold Water Inlet m 3/4" •Gas Inlet m 3/4" Vent Clearances 1 0"to combustibles 0 Condensate Outlet m 1/2" Safety Flame Rod,APS,Ignition Operation Detector,Water Temperatu re High Limit Switch,Exhaust Temperatu re High Limit Sensor, •a•mode�.°"y Devices Power Surge Fuse *Available for A"models configured in an optional ComfortFlow recirculation mode,Additionalenergy use will occur when using recirculation. Gas fired,tankless,condensing,wall-mounted water heater(s)shall be direct vent NPE Series models as manufactured by Navien,Inc.and are certified by CSA Group to the latest edition ofANSI standard Z21.10.3/CSA 4.3.Water heater(s)shall have a 15 year limited Heat Exchanger warranty and 5-year limited Parts warranty(8 year Heat Exchanger and 5-year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn naturalgas and can be for use with propane when a Field Conversion Kit is installed.Water heater(s)shall have a nominal flow rate capacity of GPM/GPH at °F rise with rated input of BTU/hr.Water heater(s)shall be vented with 2"PVC/CPVC vent pipe at a distance not to exceed 60'(or equivalent)with each elbow equal to 8'of pipe length or 3"PVC/CPVC vent pipe at a distance of 1SO'(or equivalent)with each elbow equal to 5'of pipe length.Water heater(s)is rated for 150 PSI working waterpressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WCfor natural gas and 8.0"to 13.0"WC far propane.Unit(s)shall have a steel case,dual stainless steel heat exchangers,eco premixed burner, negative pressure gas valve,dual venturi,314"inletgas connection,314"brass inlet/outlet water connections,water holding capacity of 0.6gallons for the NPE-150S,1.0 gallon for the NPE-180A model(0.7gallons for NPE-180S model),1.2gallons for the NPE-210A/NPE-240A models(0.7 and 0.9gallons for NPE-210S and NPE-240S models respectively),and a condensate collector.The NPE-1 SOS model weighs 55lbs,the NPE-180A model weighs 75lbs(NPE-18OS weighs 67lbs),and the NPE-210A/NPE-240A models weigh 82 lbs(NPE-210S and NPE-240S weigh 75lbs).Units)shall include features such as an adjustment for installations at high elevation,temperature lockout and temperature optionsfrom 98-120°Fin 10Fintervals and 125-140°Fin 5°Fintervals.The units)shall include additional temperature options of156-180°Fin 10°F intervals, and 182°Ffor high temperature commercial applications.Ail NPE"A"models shall include an internal circulation pump and O.Sgallon buffer tank.The water heater(s)shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal combustion efficiency.Unit(s)shall include safety features such as flame sensor system,high limitsensors,overheat prevention device,freeze protection mode,and fan motor rotation detector.Multi-system(cascade)applications that require 2 to 16 units shall be installed by connecting the units using cable-only connections(Ready-Link).Cascade systems can be common vented with up to 8 units when a Common Vent Backflow Damper Collar Kit is installed.The water heater(s)exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed by SCAQMD rule 1146.2(Type I)for Low NOx that complies with 14 ng/j or 20 ppm NOx requirements @ 3%02. 'Navien reserves the right to change specifications at any time withoutprior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.Navien.corn Rev.11/16 Permit#: 2299 Permit Date: 11/30/18 Permit Type: RESIDENTIAL MECHANICAL Project Nam e Andgar 81st Dr SE Applicant Nam a Andgar Mechanical LLC Applicant Address: 6920 Salashan Pkwy A-102 Applicant, City, State, Zip: Ferndale, WA98248 Contact: Phone: 360-366-9900 Em al: corporate@andgar.com Scope of Work: Replace gas water heater Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 12/03/2018 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address L egal Description O wner Nam e Ovner Phone Zoning 01040900001700 1 7315 81 ST DR NE PEPIN BRUCE A& 111 Single Fam iy TERESA M Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# Andgar Mechanical Dale Vanrooyen 3 60-366-9900 6920 Salashan MECHANICAL COA 604 255 353 LLC Parkway CONTRACTOR Andgar Mechanical Dale Vanrooyen 3 60-366-9900 6920 Salashan MECHANICAL Labor&ANDGAML825N3 LLC Parkway CONTRACTOR Industries Inspections Date I nspection Type D escription S cheduled Date C om lieted Date I nspector S tatus O1/03/2019 R00.WATER O1/03/2019 B UILDING A pproved HEATER FINAL Fees Fee D escription N otes A m Cant Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base P erm i Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter D escription 11/30/2018 Building Perm i Paym eats Date Paid By D escription P aym ait Type A ccepted By A m aunt 12/03/2018 Joliene Gwinner 7 2878615 i Transact CC $75.00 O ttstanding Balance $0.00 Uploaded Files Date File Nam e O1/11/2019 4400144-2299 1-3-2019 Inspection.pdf 12/03/2018 4245724-2299 signed perm i.pdf 11/30/2018 4240670-2299 Specs.pdf 11/30/2018 4240648-2299 Application.pdf