Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3614 186th Pl Ne Unit 8B_BLD5376_2024_Expired
Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use Notice of Decision Staff Report Application Narrative Legal Description Vicinity Map Site Plan Landscape Plan Complete Streets Checklist Traffic Impact Analysis Snohomish County Traffic Mitigation Offer WSDOT Traffic Offer Form Tree Survey Stormwater Drainage Report Geotech Report Critical Area Evaluation Form SEPA Checklist Public Notice Material Noticing and Related Documents Water / Sewer Availability Certificate Unanticipated Discovery Plan Form Aerial Photo of Site Proposed Building Materials Lighting Plans and Lighting Cut Sheets Color Elevations Design Matrix Plat Map Title Report Lot Closures Preliminary Civil Plans Archaeological Survey o Confidential Documents. Contact the City to obtain. Topography (Existing Conditions) CC&R’s Deeds / Easements / Conveyances /Dedications Developer’s Agreement Recorded Copies Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. Letters and Project Documents Other: Civil Issued Permit Application Other Applications Construction Calculation Worksheet Approved Plans Review Comment Form Letters and Project Documents Other Agency Permits Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports SEPA and Noticing Materials Inspections As-Builts Other: Building Issued Permit Application Additional Applications Approved Plans Site Plan Letters and Project Documents Calculations Project Specification Manuals Reports Certificate of Occupancy Inspections Other: BLD5376 Residential Mechanical 3614 186th Pl Ne Unit 8B EXPIRED January 2024 ✔ ✔ ✔ ✔Permit Coversheet CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 3614 186TH PL NE UNIT 8B Parcel #: 00932500800200 Permit #: 5376 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work: Water Heater Replacement Valuation: 2584.47 OWNER APPLICANT CONTRACTOR MAXIM JOSEPH DOUGLAS & ALEIS DRF Trusted Property Solutions Smart Water Experts 3614 186TH PL NE #8B 10242 BODE STREET 10242 Bode Street ARLINGTON, WA 98223 PLAINFIELD Plainfield, IL 60585 630-615-4580 630-615-7000 LIC: 604 886 829 EXP: 08/30/2023 LIC: SMARTWE782KP EXP: 08/02/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #:EXP:LIC #:EXP: JOB DESCRIPTION PERMIT TYPE:RESIDENTIAL MECHANICAL CODE YEAR:2018 STORIES:CONST. TYPE: DWELLING UNITS:OCC GROUP: BUILDINGS:OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 05/31/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, 5/31/2023 MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/31/2023 Processing/Technology $25.00 05/31/2023 Inspection $75.00 05/31/2023 Water Heater - LPG $25.00 05/31/2023 Mechanical Base $25.00 05/31/2023 Gas Piping/Units $15.00 05/31/2023 Credit Card Service $4.95 Total Due:$169.95 Total Payment:$169.95 Balance Due:$0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 REV03.2022 Page 1 of 2 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances MECHANICAL PERMIT FEES (per unit) Additional Plan Review fees x $ 75.00 = Air Cond. Unit ≤100Btu/h x $ 15.00 = Air Cond. Unit >100Btu/h x $ 25.00 = Air Cond. Unit >500Btu/h x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = Boiler >1 million Btu/h<50hp x $ 25.00 = Type of Permit: New Installation Addition/Alteration/Repair Gas Piping Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: Owner Contractor Project Description: Owner Name: Home No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: Gas Piping Information Not Applicable Proposed Piping Material: CSST Brass Other Black Steel Galvanized Steel _______________________________________ Proposed Piping Size: ½” ⅝” ¾” 1” 1½” 2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: Water Heater Replacement Arlington 98223WA Smart Water Experts 630-615-4580 permits@drftps.com 10242 S Bode St Plainfield IL 60585 SMARTWE782KP 8/2/2024 3614 186Th Pl Ne, Unit B $2,584.47 Joseph Maxim 3614 186Th Pl Ne, Unit B 360-333-9732 REV2.2020 Page 2 of 2 MECHANICAL PERMIT FEES (per unit) Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Commercial Hoods -Type I x $ 25.00 = Commercial Hoods -Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC ≤100 Btu/h x $ 15.00 = Gas Fired AC >100 Btu/h x $ 25.00 = Gas Fired AC > 500 Btu/h x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping > 5 units (plus <5 units) x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by mechanical code, not otherwise specified x $ 15.00 = Pkg. Units ≤100btu x $ 25.00 =Pkg. Units >100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 =Refrigeration Unit ≤100Btu/h x $ 15.00 =Refrigeration Unit >100Btu/h x $ 25.00 =Refrigeration. Unit >500Btu/h x $ 50.00 =Re-inspection fee x $ 75.00 =Residential Range Hood x $ 15.00 =Unit Heaters ≤ 100 Btu/h x $ 15.00 =Unit Heaters >100 Btu/h x $ 25.00 =VAV Boxes (Variable Air Volume, part of air conditioning system) x $ 10.00 = Wall Heaters - Gas Fired x $ 25.00 =Water Heater - Gas Fired x $ 25.00 =Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 1 $25.00 $50.00 $150.00 REV2.2020 Page 3 of 3 PRESSURE PIPING SCHEMATICCOMPLETE FOR GAS PIPING ONLY SCHEMATIC IS TO SCALE SCHEMATIC NOT TO SCALEShow Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. A final inspection and approval shall be obtained when complete. Signature Print Name Date SAVE PRINT Michael Lawyer 5/26/2023 5/24/2021 40 Gallon Tall 9 | A. O. Smith https://www.aosmithatlowes.com/products/water-heaters/gas-water-heaters/g9-t4040nvr/1/5 Gas Tank (/products/water-heaters/gas-water-heaters/) 40 Gallon Tall 9-Year 40,000 BTU Natural Gas Water Heater 40 GALLON TALL 9-YEAR 40,000 BTU NATURAL GAS WATER HEATER Write a review Model: G9-T4040NVR Lowe's Item #: 962538 PRODUCT FEATURES (55)★★★★★★★★★★4.7 S HOP NO W A T L OWE’S (/) 5/24/2021 40 Gallon Tall 9 | A. O. Smith https://www.aosmithatlowes.com/products/water-heaters/gas-water-heaters/g9-t4040nvr/2/5 Safety System Reduces the Risk of Accidental Fires Involving Flammable Vapors Electronic Gas Valve has fewer moving parts than a conventional mechanical gas valve, for durability and long life-no external power source is needed Self-Diagnostic Electronic Gas Control incorporates an LED status indicator that monitors and reports on system operational status Piezo Electric Igniter makes lighting the pilot fast and easy Environmentally friendly non-CFC polyurethane foam insulation reduces heat loss for maximum efficiency, saves money Ceramic tank lining and anode rod protects tank from corrosion, for long tank life Factory installed temperature and pressure relief valve ensures safe operation High-altitude certified from 0 ft to 10,100 ft (https://www.lowes.com/l/water-heater-installation.html) HOW THIS MODEL WILL PERFORM IN YOUR HOME... These stats are based on a home in Chicago, IL. To view or adjust our performance assumptions,view advanced settings 26 MINUTES single shower length 3.3 SHOWERS back-to-back 2.4 SHOWERS at the same time (/) 5/24/2021 40 Gallon Tall 9 | A. O. Smith https://www.aosmithatlowes.com/products/water-heaters/gas-water-heaters/g9-t4040nvr/3/5 NOT SURE WHICH WATER HEATER IS RIGHT FOR YOU? Try our Product Selector Tool to find the right models for your home’s needs. L a u n c h Pro d u c t Sel e c t o r (/b uy e r s -gu i d e /) Specifications Type:Tall Height:58 1/4" Height w/Draft Hood:61 3/4" Diameter:20" Width:20" Depth:20" VentType Standard Vent 61 GALLONS max tub size $194/YEAR estimated energy cost (/) 5/24/2021 40 Gallon Tall 9 | A. O. Smith https://www.aosmithatlowes.com/products/water-heaters/gas-water-heaters/g9-t4040nvr/4/5 Vent Diameter:3" Nominal Capacity: 40 Rated Storage Volume: 38 UEF:0.66 Family Size:3 Self Cleaning:Yes Limited Warranty Tank:9 years Limited Warranty Parts:9 years BTU Input:40000 BTUs Water Connection Location:Top Water Connection Size:3/4" T&P Relief Valve:Yes Ratings/Reviews Use & Care Instructions ? ? WATER HEATERS Gas Tank (/products/water-heaters/gas-water-heaters/) Electric Tank (/products/water-heaters/electric-water- heaters/) FILTERS Drinking Filters (/products/water-filters/drinking-water/) Whole Home Filters (/products/water-filters/whole- home/) (/) 5/24/2021 40 Gallon Tall 9 | A. O. Smith https://www.aosmithatlowes.com/products/water-heaters/gas-water-heaters/g9-t4040nvr/5/5 Gas Tankless (/products/water-heaters/gas-tankless/) Electric Tankless (/products/water-heaters/electric- tankless/) Replacement Filters (/products/water- filters/replacements/) MORE PRODUCTS Water Softeners (/products/water-softeners/) Expansion Tanks (/products/pressure-tanks/water- heater-expansion-tanks/) Pump Tanks (/products/pressure-tanks/well-water- pump-tanks/) SUPPORT Product Support (/support/) Product Registration (/owner-center/product- registration/) Recall Notice (http://htwtr.co/aosalrec) Contact Us (/owner-center/contact-us/) Need Water Heater Help (/owner-center/need-more- help/) WHERE TO BUY (/WHERE-TO-BUY/) © 2018 A. O. Smith. All rights reserved. Privacy Policy (/owner-center/privacy/) (/) !"!%& '()*+,'-./".'-./.01'2.*.3-6& 7/89-.:;/<0./-=<18-)<394>>?? @ABCFDG ;7E#6% 7;./*)-.0'/-*.3- H#6 + @ +A IJ5 0./*)-9K:/L-09M2<*#NO#P ,'-./".'-./.01'2.*.3-Q5R#6 IAMART #NF#? #6 %W#R XE#> X??R> @JY? @@ FR? Z;?[6># *./.9)''\1)9::/.99 .^'1.92/)0-)<3 C\3./'*. C\3./;_<3. @A@I ";aIB Z bC;"Cacd@A)3.9):.3!<3:<*!<**<-</ ;/)*'/=!<3-'2- ;_<3. ::/.99 !<3-/'2-</=0. )2.39.0./-9 + @ +@AB<:.-/..-!Ca!C!C!C!C ! " #$ $ % & ' ) * + /23456# FGHIJHKL MNOPHQRNS TUOPV WNXHJNKQHYI ZN[\YKH[YI ]^^IH[YQHUK% ' % ' c' - +d,0,e,,0,e, #fgh4D45bAibj k565b>@ pqqrqstrVuvutvqtpwFxyqtz{w|XXpqqruusqVuvutvquwFxyqpqqruussVuvutvquwFxy