Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20201 79TH DR NE_BLD1842_2026
Request Account Sign In I Contact Us Resources I Find a Store JOHNSTONE M.SUPPLY -Enter search terms here PRODUCT KNOWLEDGE SERVICE View Mfr.List HVAC HVACR Hydronics Motors Refrigeration Supplies Equipment Parts &Plumbing Home> HVAC Equipment> Residential Unitary> Gas Furnaces> 80%AFUE Efficiency> Singie-Stage> Multi-Position> Enlarge Image 80% AFUE Multi-Position Gas Furnaces TG8S Series, Single-Stage, 33" Height AFUE:80.0%;Configuration:Multi-Position;BtuH Input:40,000;BtuH Output:32,000: Nom.CFM:800;Min.Circuit Amps:4.5;Vent Size:4",Motor Type:PSC;Width:14-1/2"; Height:33";Depth:29-1/2";Wt.Lbs.:89;Stages:Single-Stage;LoNox:No; Order#:L98-793 Mfg.#:TG8SO40A08MP11 Catalog Page: 700 Brand:Coleman Not what you're looking for? Similar products All Coleman products Multi-Position from Coleman Specifications Description Warranty Datasheets Notes Product Specifications Description AFUE 80.0% • Multi-position upflow,horizontal left or right or downflow • PSC four-speed direct drive motor with large,quiet blower BtuH Input 40000 • Airflow leakage rate of less than 1%of total airflow @ 1"ESP BtuH Output 32,000 • Full 400 CFM per ton airflow ratings @.5"ESP fi uration Multi-Position • Single-stage gas valve Configuration • Electronic hot surface ignitor Depth 29-1/2" • Tubular aluminized steel primary heat exchanger Descriptor TG8S 80%AFUE Single-Stage PSC • Built-in,high-level self-diagnostic controls with fault codes • External air filters(not included) Height 33" . All models are propane convertible LoNox No • LoNOx models meet specific code requirements;see Min.Circuit Amps 4.5 www.JohnstoneSupply.com for complete information and product selection Motor Type PSC Nom.CFM 800 Stages Single-Stage Vent Size 4" Width 14-1/2" Warranty Wt.Lbs. 89 WARRANTY-Johnstone Supply will administer and promptly process all Shipping Weight 94.00 warranties in accordance with the manufacturer's specific warranty policies Shipping Width 16.00 and procedures. Shipping Length 32.00 WHOLESALE ONLY-Identification is required of purchasers.Possession of Shipping Height 37.00 Johnstone's catalog does not constitute an offer to sell by Johnstone or the right to purchase from us. RETURNS-All returns are subject to a restocking charge. Datasheets and Resources Accessories © Brochure © Parts List ® Submittal Data Form ® Technical Manual Compliance/Notes Harmonize Code 7322.90.1021 Country of Origin UNITED STATES See catalog page 700 for additional notes and/or restrictions. Johnstone Info Contractor Resources Programs Help Center Opportunities About Johnstone Tax Credits Johnstone University Contact Us Career Supply eCatalog NATE Site Overview Opportunities Sales Policy Manufacturer Listing Radius Marketing Website-How To Ownership Press Releases Credit Application Contractor Promotions Opportunities SDS (Fillable PDF) Vendor Collateral Mobile Site Johnstone Mobile Toolkit Terms of Use Privacy Statement Employee Network Login Store Content Manager Copyright©2018 Johnstone Supply.All rights reserved. This site is optimized for IE7 or later,Firefox,Chrome and Safari RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:20201 79th Dr NE Project Description:replace furnace like and kind Owner: Russ Patrick Address. 20201 79th Dr NE City. Arlington State.WA Zip Code: 98223 Phone: 4252053845 Email:russpatrick@live.com Applicant: Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville State.WA Zip Code: 98270 Phone. 360-658-9500 Email. info@paragonheating.com CONTRACTOR INFORMATION Contractor Name:Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville StateWa Zip Code: 98270 License Number: PARAGHC8632A Expiration. 5/1/18 Phone: 360-658-9500 Email:info@paragonheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #ML180DF045024 AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances L07 Applicant Signature: d5a513be"a92O�tlb81'e`1e6' Date: 02/26/2018 Applicant Printed Name: Jeana Brennan I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N.OLYMPIC AVE- ARLINGTON, WA. 98223 PHONE;(360)403-3551 BUILDING PERMIT Address:20201 79th Drive NE Permit#:1842 Parcel#:00825900000700 Valuation:0,00 OWNER APPLICANT CONTRACTOR Name:PATRICK RUSSELL G 8c DEBBIE L Name:Paragon Heating and Home Comfort Name:Paragon Heating Solutions Address:20201 79TH DR N E Address PO Box 798 Address:P.O Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:P O,Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip. Phone:360-658-9500 Phone. LIC#:PARAGHC8632A EXP: 05/01/2018 LIC# EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 1 CONST.TYPE: \/B DWELLING UNITS: I OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27, THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A(A-�TIFIC',TE OF OCCUPANCY HAS BEEN GRANTED. IBC I I0/IRC 110, S LE T TICE:Selicos tax relating to construction and constru on materials in the City of Arlington mu b, rt d j' r sales tax return form a d c0 ' , o-. 1 0 #31 1 Signature Print Name Date c Date CONDITIONS Approved as submitted. Adhere to the installation of model#TG8SO4OAO8MP11 AFUE 80% THIS PERMIT AUTHORIZE ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC)WILL REQUIRE SEPARATE PERMISSION. PERMIT-FEES Date Description Fee Amount 3/5/2018 Furnace $25.00 3/5/2018 Mechanical Permit Base Fee $25.00 3/5/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: S75.00 Balance Due: S0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 �. PHONE; (360)403-3551 BUILDING PERMIT Address:20201 79th Drive NE Permit#:1842 Parcel#:00825900000700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PATRICK RUSSELL G&DEBBIE L Name:Paragon Heating and Home Comfort Name:Paragon Heating Solutions Address:20201 79TH DR N E Address:PO Box 798 Address:P.O.Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:P.O.Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC#:PARAGHC8632A EXP: 05/01/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 1 CONST.TYPE: `/B DWELLING UNITS: 1 OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of A in ust a rted on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date cased By Date CONDITIONS Approved as submitted. Adhere to the installation of model #ML180DFE AFUE 80% THIS PERMIT AUTHORIZS ONLY THE WORK NOTED THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 3/2/2018 Furnace $25.00 3/2/2018 Mechanical Permit Base Fee $25.00 3/2/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0 00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:20201 79th Drive NE Permit#:1842 Parcel#:00825900000700 Valuation:0.00 APPLICANT CONTRACTOR Name:PATRICK RUSSELL G&DEBBIE L Name:Paragon Heating and Home Comfort Name:Paragon Heating Solutions Address:20201 79TH DR N E Address:PO Box 798 Address:P.O.Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 MECHANICAL CONTRACTOR t PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:P.O.Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC#:PARAGHC8632A EXP: 05/01/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 1 CONST.TYPE: ` B DWELLING UNITS: 1 OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC1 I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Approved as submitted. Adhere to the installation of model#TG8SO4OAO8MP11 AFUE 80% THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 3/5/2018 Furnace $25.00 3/5/2018 Mechanical Permit Base Fee $25.00 3/5/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Community and Economic Development , Building Division INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit SITE holder or agent has posted this Inspection Record Card in a conspicuous place on the premises. OWNER: RUSSEL AND DEBBIE PATRICK CONTRACTOR: PARAGON HEATING AND HOME COMFORT SOLUTIONS JOB ADDRESS:20201 79TH DRIVE NE OWNERADDRESS: 20201 79TH DRIVE NE USE of BUILDING: SFR PLAT NAME: VB R3 Description of Work: REPLACE GAS FURNACE LOT# PERMIT NO: BLD-1842 Sprinklered:NO CONDITIONS. SEE PERMIT/CALL FOR INSPECTION DATE ISSUED:3/2/2018 TYPE IGROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION INSPECTION LINE UNDERFLOOR (360)403-3417 SHEARWALL PLUMBING (groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE DEVELOPMENT STORM INFILTRATION SERVICES GRADING INSPECTION LINE CURB GUTTER&SIDEWALK (360)403-3417 LANDSCAPE DRIVEWAY UTILITIES SIDE SEWER INSPECTION LINE SEWER CLEANOUT/FINAL (360)403-3508 WATER SERVICE INSPECTION WATER SERVICE FINAL CROSS CONNECTION FINAL (360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection Electrical must be signed off prior to final inspection COMMENTS: GAS FURNACES M LISODFE LENN7717IX ) MERIT° SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS Bulletin No.210614 January 2012 Supersedes November 2011 �J ZMN,9 1 � 0 o � r` nnn 0 � � nnnnnnnna rn ri r,n AFUE - 80% Input - 44,000 to 110,000 Btuh Nominal Add-on Cooling - 1.5 to 5 Tons MODEL NUMBER IDENTIFICATION M L 1 80 DF 070 E 36 B Unit Type �'Cabinet Width ML=Merit Series® A= 14-1/2 in. B= 17-1/2 in. Stages C=21 in. 1 =Single-Stage AFUE Nominal Add-On Cooling Capacity 80=80% 36=1.5-3 tons Configuration 48=2.5-4 tons DF=Downflow 60=3-5 tons Nominal Gas Heat Input 045=44,000 Btuh Blower 070=66,000 Btuh E=High Efficiency Constant Torque Blower Motor 090=88,000 Btuh 110=110,000 Btuh Indoor coils with the same letter designation will physically match the furnace. FEATURES i CONTENTS -- Blower Data. . . . . . . . . . . . . . . . . . . . . . 10 © Dimensions . . . . . . . . . . . . . . . . . . . . . . 7 Dimensions - Furnace/Coil Combined Dimensions. . 9 Features. . . . . . . . . . . . . . . . . . . . . . . . 2 Gas Heat Accessories . . . . . . . . . . . . . . . . 5 f S v High Altitude Derate. . . . . . . . . . . . . . . . . . 6 10 Installation Clearances . . . . . . . . . . . . . . . . 6 Model Number Identification . . . . . . . . . . . . . 1 Optional Accessories . . . . . . . . . . . . . . . . . 5 Optional Accessory Dimensions . . . . . . . . . . . 8 Specifications . . . . . . . . . . . . . . . . . . . . . 5 O NOTE - ML180DFE FURNACES ARE NOT AVAILABLE IN CANADA! WARRANTY APPLICATIONS DuralokTm Aluminized Steel Heat Exchanger Input capacities of 44,000, 66,000, 88,000 and 110,000 - Limited twenty year warranty in residential Btuh. applications, ten years in non-residential applications. Energy efficiency (AFUE) of 80%. All other covered components- Limited five year Compact cabinet for downflow applications without any warranty in residential applications, one year in non- internal modifications to the unit. residential applications. Lennox add-on indoor coils, high-efficiency air cleaners Refer to Lennox Equipment Limited Warranty certificate and humidifiers can easily be added to furnace. included with equipment for details. Shipped factory assembled with all controls installed APPROVALS and wired. Units are Certified by AHRI. Each unit factory test operated to ensure proper Units tested and rated according to US DOE test operation. procedures and FTC labeling regulations. NOTE - FURNACES CANNOT BE TWINNED! ISO 9001 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. ML180DFE/Page 2 FEATURES HEATING SYSTEM O Flame Rollout Switch O Lennox DuralokTm Heat Exchanger Assembly Manual reset switch is factory installed inside burner Heavy gauge aluminized steel heat exchanger. box. Crimped seam clamshell type design. Switches provides protection from abnormal operating Designed for normal expansion and contraction. conditions. Minimum resistance to Limit Controls air flow. Automatic reset, primary and secondary limits are f - - ���' accurately located. � Heat exchanger has been laboratory life Primary limit factory installed on vestibule panel on cycle tested in excess of all units, secondary limit factory installed on blower industry standards. housing. Compact size of heat OPTIONS exchanger permits low g p 4 High Altitude Pressure Switch Kit L overall design of furnace Required on most units for proper unit operation at Inshot Burners cabinet. altitudes from 4,501 to 7500 ft. © Natural Gas to LPG/Propane Conversion Kit Aluminized steel Inshot burners provide efficient,trouble-free operation. Required for field changeover from natural gas to LPG/ Burner venturi mixes air and gas in correct proportion Propane. for proper combustion. LPG/Propane to Natural Gas Conversion Kit Burner assembly is removable from the unit as a single Required for field changeover from LPG/Propane to component for ease of service. natural gas. © SureLight®Hot Surface Ignitor BLOWER Tough, reliable, long-life, trouble-free performance. © Direct drive blower. Silicon nitride ignitor. Statically and dynamically balanced. Cemented to steatite block for protection against current Resiliently mounted. leakage. Blower assembly easily removed for servicing. Ignition leads are constructed of nickel plated copper DC Brushless Motor and are enclosed in high temperature Teflon° insulation High Efficiency Constant Torque. for dependable operation. 0 Gas Control Valve ECM (Electronically Commutated Motor). Motor is programmed to provide constant torque at each 24 volt redundant combination gas control valve combines manual shut off switch (On-Off), automatic of the selectable speeds. electric valve (dual)and gas pressure regulation into a Motor is controlled by the Integrated Furnace Control. compact combination control. Blower speeds are easily changed on the integrated © Combustion Air Inducer furnace control. See blower performance tables. Shaded pole heavy duty blower prepurges heat exchanger and safely vents flue products. Pressure switch proves blower operation before allowing gas valve to open. Operates only during heating cycle. ML18ODFE/Page 3 FEATURES 0 CONTROLS Night Service Kit SureLight° Integrated Furnace Control Contains most commonly used service parts: Control contains all necessary controls and relays to • Furnace Control operate furnace. • Ignitor Combustion air inducer is operated by the integrated • Flame sensor furnace control. Prior to ignition, a pre-purge cycle for 15 seconds is initiated.After the main burners are Gas valve turned off, a post-purge cycle for 5 seconds is run. • Transformer Flame sensor assures safe and reliable operation. Universal Service Kit- Switches Should loss of flame occur the integrated furnace Kit contains: control will initiate 4 re-attempts at ignition before • Primary limits (for each model) locking out unit operation for 60 minutes. • Pressure switches (for each model) Watchguard type circuit automatically resets ignition • Flame rollout switches (for each model) controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. CABINET Fan control consists of adjustable blower timed-off delay Low-profile, narrow width cabinet allows easy (60, 90, 120, 180 seconds -factory setting 90 seconds) installation in downflow applications. and fixed blower timed-on delay (30 seconds- heating, Heavy-gauge, cold rolled steel construction. 2 seconds - cooling). Pre-painted cabinet finish. For air-conditioning applications, blower is automatically energized on thermostat demand for cooling. Control Flanges provided on supply air opening for ease of has low speed continuous blower speed setting for plenum connection or alignment with indoor coil. humidifier or air cleaner operation. Qj Insulated cabinet with foil faced insulation on sides and Two accessory terminals furnished for additional back of heating compartment. power supply requirements for 120 volt (less than 1 Sealed blower compartment. Inner blower compartment amp) power humidifiers and powered air cleaners. access panel seals blower compartment from air One addiitonal terminal is furnished for power supply leakage. requirements for 24V (less than 0.5 amp) low voltage Complete service access. accessories. Safety interlock switch automatically shuts off power Ignition control has single red LED to indicate status to unit when blower compartment access panel is and as an aid in troubleshooting. removed. Last five codes are stored in non-volatile memory Gas piping and electrical inlets are provided in both (accessible by recall button on control for servicing. sides of cabinet. Q 24 Volt Transformer Coil Match-up Furnished and factory installed on outside of control All furnaces exactly match CR33 cased, downflow box. 40VA transformer has fuse wired in series. indoor coils with adaptor rails, furnished with coil. Field Wiring Make-up Box OPTIONS Furnished for line voltage wiring. Downflow Combustible Flooring Base Factory installed internally on left side of furnace. Required for heating only units installed on combustible Box may be installed on right side of furnace. floors. OPTIONS Not required in add-on cooling applications. Blower Relay Kit See Dimension Drawing. (For Use With Two-Stage Outdoor Units) FILTER Allows furnace blower speed changes when matched with two-stage air conditioners or heat pumps. OPTIONS Thermostat Downflow Filter Cabinet Thermostat (programmable/non-programmable) is not Filter cabinet mounts directly on top of furnace. furnished with unit. "A"width cabinet includes one filter. See Thermostat bulletins in Controls Section and "B and "C"width cabinets have two filters. Lennox Price Book for selection. Filter rails are furnished. Front access for servicing. Cleanable filter(s) are furnished. ML180DFE/Page 4 SPECIFICATIONS Gas Model No. ML180DF045E36A ML180DF07OE36B ML180DF09OE48B ML18ODF11OE60C Heating 1 AFUE 80% 80% 80% 80% Performance Input- Btuh 44,000 66,000 88,000 110,000 Output- Btuh 36,000 54,000 72,000 90,000 Temperature rise range- °F 15-45 30-60 30-60 30-60 Gas Manifold Pressure (in.w.g.) 3.5/10.0 3.5/10.0 3.5/ 10.0 3.5/ 10.0 Nat. Gas/LPG/Propane High Static-in.w.g. 0.50 0.50 0.50 0.50 Connections Flue connection-in. round 4 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Indoor Wheel nom. dia.x width-in. 10 x 8 10 x 10 10 x 10 11-1/2 x 10 Blower Motor Type DC Brushless DC Brushless DC Brushless DC Brushless Motor output-hp 1/2 1/2 3/4 1 Tons of add-on cooling 1.5-3 1.5-3 2.5-4 3-5 Air Volume Range-cfm 355- 1430 430- 1475 680- 1750 990-2410 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.8 6.8 8.4 10.9 Maximum overcurrent protection 15 15 15 15 Shipping Data lbs. - 1 package 113 128 140 160 NOTE-Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE-FURNACES CANNOT BE TWINNED! "A"Width "B"Width "C"Width Models Models Models CABINET ACCESSORIES Downflow Combustible Flooring Base 11M59 11M60 11M61 CONTROLS Blower Relay Kit(for two-stage outdoor units) 85W66 85W66 85W66 FILTERS Downflow Filter Cabinet 51W06 I 51W07 51W08 No. and Size of filter-in. (1)20 x 20 x 1 (2)20 x 16 x 1 (2)20 x 16 x 1 SERVICE KITS Night Service Kit 84W47 I 84W47 84W47 Universal Service Kit-Switches 89W19 89W19 89W19 Cleanable polyurethane,frame-type filter. GAS HEAT ACCESSORIES High Altitude Natural Gas to LPG/Propane Natural Gas Input Pressure Switch Kit LPG/Propane Kit to Natural Gas Kit High Altitude p Orifice Kit 0-4500 ft. 4501 -7500 ft. 7501 - 10,000 ft. 0-7500 ft. 7501 -10,000 ft. 0-7500 ft. 7501 - 10,000 ft. 045 No Change No Change 80W51 70W89 76W15 73W81 73W37 070 No Change 80W52 8OW51 70W89 76W15 73W81 73W37 090 No Change No Change 80W51 70W89 76W15 73W81 73W37 110 No Change 80W52 80W51 70W89 76W15 73W81 73W37 ML180DFE/Page 5 HIGH ALTITUDE DERATE NOTE-Units may be installed at altitudes up to 4500 ft. above sea level without any modifications. At altitudes above 4500 ft. units must be derated to match information in the shaded areas shown below. NOTE-This is the only permissible derate for these units. Gas Manifold Pressure(Outlet) in.w.g. Line Pressure-in.w.g. Input 0-4500 Feet 4501 -7500 Feet 7501 -10,000 ft. Minimum Natural LPG/ Natural LPG/ ' Natural LPG/ Natural LPG/ Maximum Gas Propane Gas Propane Gas Propane Gas Propane 045 3.5 10 3.5 10 3.5 10 4.5 11 13 070 3.5 10 3.3 10 3.5 10 4.5 11 13 090 3.5 10 3.3 10 3.5 10 4.5 11 13 110 3.5 10 3.3 10 3.5 10 4.5 11 13 Natural Gas High Alitude Orifice Kit required. INSTALLATION CLEARANCES Vent Type Type 1131 Type C Sides 0 in. (0 mm) ' 0 (0) Rear 0 in. (0 mm) 0(0) Top 1 in. (25 mm) 1 (25) Front 2-1/4 in. (57 mm) 2-1/4(57) Front(service/alcove) 24 in. (610 mm) 24 (610) Floor 2 Combustible 2 Combustible Flue 1 in. (25 mm) 6(152) NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ANSI-Z223.1). NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable provisions of local building codes. Left side requires 4 in.if single wall vent is used on 14-1/2 in."A"width cabinets,2 in.on 17-1/2 in."B" width cabinets. 2 Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed between furnace and combustible floor.Not required in add-on cooling applications if installed in accordance with local codes,National Fuel Gas Code ANSI-Z223.1 or National Standard of Canada CAN/CSA-B149.1 and CAN/CSA-B149.2 Installation Code for Gas Burning Appliances". Do not install the furnace directly on carpeting,tile,or other combustible materials other than wood flooring. ML180DFE/Page 6 DIMENSIONS - INCHES (MM) 3-1/8 9/16 (79) (14) ° D RETURN AIR B OPENING FLUE OUTLET/ (TOP) 19-7/16 9/16 (494) (14) 9/16 (14) TOP VIEW A 3/4(19) 27-3/4 Front Panel (705) B 9/16 19-7/16 9/16 (14) � (494) (14) FLOW AIR W O ELECTRICAL INLET 0 0 (Either Side) aaaaaaaaeaaee 33 e vvvvvvvvvvvvv (838) vvvvvvvvvvvvv o e o o.o 0 0.0 5-3/8 vavv vavv vavv vavv vavv vavv vavv vavv vavv vavv vavv vavv vavv GA (137i)Right e e S PIPING INLE T f2-3/16(56)Left (Either Side) 6-5/8(168)Right 7-1/8(181)Le e e 3/4 C Supply 3/4 19-1/4 SuPPIY J 3/4 (19) Air (19) (489) Air (19) FRONT VIEW SIDE VIEW A B C D Model No. in. mm in. mm in. mm in. mm ML180DF045E36A 14-1/2 368 13-3/8 340 13 330 4-3/4 121 ML180DF07OE36B 17-1/2 446 16-3/8 416 16 406 6-1/4 159 ML180DF09OE48B ML180DF11OE60C 21 533 19-7/8 505 19-1/2 495 8 203 ML18ODFE/Page 7 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) DOWNFLOW FILTER CABINET "A"WIDTH FURNACES "B AND "C"WIDTH FURNACES (Single Filter) (Two Filters) 17-1/2 445)"B"Box 20-1/ 4-1/2 20-1/ (521) (368 '(521) 21 `\ 17-1/2 FILTER(1) (533) FILTERS(2) (445) m ® 50-1/2 (1 54 542) (1283) 33 / 33 (838) (838) FILTER ACCESS DOOR FURNACE FURNACE FILTER ACCESS DOOR NOTE: Return Air Opening(W x D) "A"Box 13-1/2 x 19-5/8(343 x 498) "B"Box 16-1/2 x 19-5/8(419 x 498) "C"Box 20 x 19-5/8(508 x 498) ML180DFE/Page 8 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE 1-1/2 (38) <:> SUPPLY AIR OPENING 19-13/16 21-13/16 DOWN (503) 27-1/4 (554) FLOW 1-1/2 (692) FURNACE (38) B 1-1/2 n (38) \ Front Of Furnace u A (3 (38)) TOP VIEW SIDE VIEW \K Cabinet Catalog A B C DOWNFLOW Width Number in. mm in. mm in. mm COMBUSTIBLE A 11 M59 16-9/16 421 13-9/16 344 15-3/4 400 FLOORING BASE B 11 M60 19-9/16 497 16-9/16 421 18-3/4 476 ' C 11M61 23-1/16 586 20-1/16 510 22-1/4 565 FLOOR OPENING 5-, (559 C DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS /Furnace Width Coil Furnace Coil Overall Model Width Width Height Height Number in. mm in. mm in. mm in. mm CR33-18A-F 17-1/2 446 14-1/2 368 14-1/8 359 47-1/8 1197 33 (838) CR33-24A-F 17-1/2 446 14-1/2 368 14-1/8 359 47-1/8 1197 ® Overall CR33-24B-F 17-1/2 446 17-1/2 446 14-1/8 359 47-1/8 1197 Height CR33-30/36A-F 17-1/2 446 14-1/2 368 16-1/8 410 49-1/8 1248 ° CR33-30/36B-F 17-1/2 446 17-1/2 446 16-1/8 410 49-1/8 1248 CR33-30/36C-F 21 533 21 533 16-1/8 410 49-1/8 1248 ORtZG%mt®° a 0 CR33-4813-F 21 533 17-1/2 446 20 508 53 1346 Coil \ •�� � Height CR33-48C-F 21 533 21 533 20 508 53 1346 CR33-50/60C-F 24-1/2 622 21 533 23-5/8 600 56-5/8 2276 Coil Width 7 ML18ODFE/Page 9 BLOWER DATA ML180DF045E36A PERFORMANCE (Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1430 285 1215 180 1035 120 995 110 930 100 0.10 1400 285 1175 185 995 130 885 100 850 90 0.20 1375 300 1145 200 950 140 840 110 725 85 0.30 1335 315 1120 210 915 145 790 115 665 95 0.40 1320 325 1075 220 870 155 745 125 625 100 0.50 1275 335 1045 230 835 165 715 135 565 105 0.60 1245 345 1000 235 785 170 655 140 520 115 0.70 1215 355 970 245 745 180 605 150 355 130 0.80 1175 365 925 255 695 185 555 155 400 130 ML18ODF07OE36B PERFORMANCE (Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1475 275 1345 170 1225 135 1185 125 1110 105 0.10 1430 290 1275 175 1190 145 1155 135 1005 95 0.20 1400 295 1230 190 1125 160 1110 150 900 100 0.30 1360 310 1205 205 1085 160 1055 155 845 115 0.40 1310 325 1155 210 1050 175 1000 165 790 115 0.50 1280 335 1110 220 985 185 950 180 705 130 0.60 1250 350 1060 235 935 195 865 185 645 135 0.70 1220 355 1000 245 865 205 815 195 590 140 0.80 1165 365 935 250 795 210 750 200 480 145 ML180DF09OE48B PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1750 385 1550 265 1430 205 1355 185 1195 130 0.10 1725 390 1495 270 1390 220 1320 195 1145 140 0.20 1695 405 1470 285 1340 235 1280 210 1105 145 0.30 1660 415 1425 300 1290 240 1225 215 1040 160 0.40 1615 430 1395 310 1250 255 1185 230 1005 170 0.50 1570 450 1360 325 1210 265 1145 240 945 180 0.60 1545 465 1295 340 1165 280 1085 255 865 185 0.70 N/A N/A 1265 350 1120 295 1040 265 810 200 0.80 N/A N/A 1215 365 1080 305 1000 275 755 210 ML180DF110E60C PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2410 625 2095 405 1875 295 1700 225 1635 180 0.10 2385 630 2100 415 1830 310 1610 240 1505 190 0.20 2325 650 2010 440 1760 330 1570 255 1375 195 0.30 2280 675 1940 460 1705 340 1500 260 1320 210 0.40 2235 690 1895 475 1635 365 1440 285 1265 225 0.50 2165 710 1845 490 1595 380 1380 300 1200 235 0.60 2125 735 1800 510 1545 390 1320 310 1170 250 0.70 2090 740 1755 530 1510 405 1285 325 1100 260 0.80 2035 760 1700 540 1460 425 1255 345 1030 275 ML180DFE/Page 10 REVISIONS Sections Description of Change Dimensions Updated. SO ,A"IMF1 `��jjr REGISTERED QUALITY SYSTEMS Visit us at www.lennox.com LENN17XFor the latest technical information,www.lennoxdavenet.com 0 Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2012 Lennox Industries,Inc. Agahk CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 1W PHONE;(360)403-3551 BUILDING PERr#M Address:20201 79th Drive NE Permit#:1842 Parcel#:00825900000700 Valuation:0,00 OWNER APPLICANT CONTRACTOR Name:PATRICK RUSSELL G&DEBBIE L Name:Paragon Heating and Home Comfort Name:Paragon Heating Solutions Address:20201 79TH DR N E Address:PO Box 798 Address:P 0 Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone-360-658-9500 Phone:360-658-9500 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:P 0.Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC# PARAGHC8632A EXP'. 05/01/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 1 CONST TYPE: `/B DWELLING UNITS: l OCC GROUP: R3 BUILDINGS: OCC LOAD: PERIVIIT APPROVAL I AGREE'r0 COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A t TIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBC 110/IRC 110. ti LE"I" )TICS: ' Ies relating to construction and construI`1 lllon�"materialsn the City oJf(ArlingtOn mu rt d o y Sales tax return form apJ co ' o t 01 p31 1�' n `�/ is J•�.2 .ignature Print Name Date a Date CONDITIONS Approved as submitted.Adhere to the installation of model#TG8SO40A08MP l 1 AFUE 80% THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC)WILL REQUIRE SEPARATE PERMISSION. PERNM FEES Date Description Fee Amount W5/2018 Furnace $25.00 3/5l2018 Mechanical Permit Base Fee $25.00 3/5/2018 Processing/rechnology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �` 1 � � _ • _'��1~ J• �� r r ' CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:20201 79th Drive NE Permit#:1842 Parcel#:00825900000700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PATRICK RUSSELL G&DEBBIE L Name:Paragon Heating and Home Comfort Name:Paragon Heating Solutions Address:20201 79TH DR N E Address:PO Box 798 Address:P.O,Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:P.O.Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC#:PARAGHC8632A EXP: 05/01/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: I CONST.TYPE: VB DWELLING UNITS: I OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City ofA in usl e e rted on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date , eased By Date CONDITIONS Approved as submitted. Adhere to the installation of model #ML 180DFE AFUE 80% THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 3/2/2018 Furnace $25.00 3/2/2018 Mechanical Permit Base Fee $25.00 3/2/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ��� � � V � / � � • � � t Permit Information Date 3/2/2018 Permit Number 1842 Project Name Patrick Applicant Name Paragon Heating and Home Comfort Solutions Applicant Address PO Box 798 City, State,Zip Marysville,WA 98270 Contact Jeana Brennan Phone 360-658-9500 Email info@paragonheating.com Permit Type Residential Mechanical Site Address 20201 79th Drive NE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Replace Gas Furnace Assigned To Kristin Foster Property Owner Parcel Address Legal Owner Phone Zoning 00825900000700 20201 79TH DR PATRICK RUSSELL G& 111 Single Family Residence- NE DEBBIE L Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# IParagonHeating I.JeanaBrennan 360-658-9500 info(o)para onheatin .com CONTRACTOR 1-abor&Industries JIDARAGHC863KA Fees Fee Description Notes Amount Furnace 322 10.00.06 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $75.0 Notes Date I Note 3/2/2.018 Model i/ML18ODFF AFUE 80% Uploaded Files Upload File Date File Uploaded By 3/2/2018 6:44.19 AM 1842 Awlication.pdf Foster. Kristin X 3/2/2018 6:44.18 AM 1842 Specs.odf Foster, Kristin 3/2/2018 Paragon Htg/Hm Cmft Sltns LLC Search L&I Washington State Department of Labor & Industries Paragon Htg/Hm Cmft Sitns LLC Owner or tradesperson PO Box 798 MARYSVILLE,WA 98270 Principals 425-252-1807 Brennan,Jeana Anne SNOHOMISH County Ingham,PARTNER/MEMBER BRENNAN,SCOTT MATTHEW,PARTNER/MEMBER Doing business as Paragon Htg/Hm Cmft Sltns LLC WA UBI No. Business type 603 395 569 Limited Liability Company Governing persons JEANA BRENNAN SCOTT BRENNAN; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PARAGHC8632A Effective—expiration 05/01/2014—05/01/2018 Bond RLI Ins Co $12,000.00 Bond account no. LSM0614502 Received by L&I Effective date 05/01/2014 05/01/2014 Expiration date Until Canceled Insurance Truck Ins Exchange $2,000,000.00 Policy no. 605833231 Received by L&I Effective date 04/05/2017 05/01/2014 Expiration date 05/01/2018 Savings ................ No savings accounts during the previous 6 year period. https://secure.ini.wa.gov/verify/Detaii.aspx?UBI=603395569&LIC=PARAG HC8632A&SAW= 1/2 3/2/2018 Paragon Htg/Hm Cmft Sltns LLC Lawsuits against the bond or savings No lawsuits against the bond or savings accou. during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 307,488-00 Doing business as PARAGON HEATING&HOME COMFORT Estimated workers reported Quarter 4 of Year 2017"1 to 3 Workers" L&I account contact T2/LINDA ALGUIRE(360)902-4678-Email:POTH235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. ',Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. hftps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603395569&LIC=PARAGHC8632A&SAW= 2/2 GAS FURNACES M LISODFE LENVNVX MERIT"SERIES ® Downflow- High Efficiency Blower Motor PRODUCT SPECIFICATIONS Bulletin No.210614 _ - — January 2012 Supersedes November 2011 itnnr�i�. nrl rl rl ram.,^ri? r-1 rl nrrr., AFUE - 80% Input - 44,000 to 110,000 Btuh Nominal Add-on Cooling - 1.5 to 5 Tons MODEL NUMBER IDENTIFICATION ML180DF070E36B Unit Type 'Cabinet Width MIL=Merit Series® A=14-1/2 in. B=17-1/2 in. Stages C=21 in. 1 =Single-Stage AFUE Nominal Add-On Cooling Capacity 80=80% 36=1.5-3 tons Configuration 48=2.5-4 tons DF=Downflow 60=3-5 tons Nominal Gas Heat Input 045=44,000 Btuh Blower 070=66,000 Btuh E=High Efficiency Constant Torque Blower Motor 090=88,000 Btuh 110=110,000 Btuh Received FEB 26 2018 ' Indoor coils with the same letter designation will physically match the furnace. FEATURES CONTENTS � Blower Data. . 10 1. Dimensions . 7 _ Dimensions- Furnace/Coil Combined Dimensions. 9 Features. . . . . . . . . . . . . . . . . . . . . . . . 2 Gas Heat Accessories . . . . . . . . . . . . . . . 5 , High Altitude Derate. 6 6- Installation Clearances . . . . . . . . . . . . . . 6 sWANAV0 Model Number Identification . . . . . . . . . . . Optional Accessories . . . . . . . . . . . . . . . . . 5 Optional Accessory Dimensions . . . . . . . . . . 8 Specifications . . . . . . . . . . . . . . . . . . 5 O S p 8 i AD NOTE-ML18ODFE FURNACES ARE NOT AVAILABLE IN CANADA! WARRANTY APPLICATIONS DuralokTm Aluminized Steel Heat Exchanger Input capacities of 44,000, 66,000, 88,000 and 110,000 - Limited twenty year warranty in residential Btuh. applications, ten years in non-residential applications. Energy efficiency (AFUE)of 80%. All other covered components- Limited five year Compact cabinet for downflow applications without any warranty in residential applications, one year in non- internal modifications to the unit. residential applications. Lennox add-on indoor coils, high-efficiency air cleaners Refer to Lennox Equipment Limited Warranty certificate -and-humidifier can-easily-be added to furnace. - - - - included with equipment for details. Shipped factory assembled with all controls installed APPROVALS and wired. Units are Certified by AHRI. Each unit factory test operated to ensure proper Units tested and rated according to US DOE test operation. procedures and FTC labeling regulations. NOTE - FURNACES CANNOT BE TWINNED! ISO 9001 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. ML18ODFE I Page 2 FEATURES HEATING SYSTEM ® Flame Rollout Switch 0 Lennox DuralokTm Heat Exchanger Assembly Manual reset switch is factory installed inside burner Heavy gauge aluminized steel heat exchanger. box. Crimped seam clamshell type design. Switches provides protection from abnormal operating Designed for normal expansion and contraction. conditions. _ Minimum resistance to Limit Controls ~ air flow. Automatic reset, primary and secondary limits are Heat exchanger has accurately located. ' been laboratory life Primary limit factory installed on vestibule panel on �• ,�c. cycle tested in excess of all units, secondary limit factory installed on blower industry standards. housing. Compact size of heat OPTIONS exchanger permits low High Altitude Pressure Switch Kit overall design of furnace Required on most units for proper unit operation at Inshot Burners cabinet. altitudes from 4,501 to 7500 ft. ©Aluminized steel inshot burners provide efficient, Natural Gas to LPG/Propane Conversion Kit trouble-free operation. Required for field changeover from natural gas to LPG/Burner venturi mixes air and gas in correct proportion Propane. for proper combustion. LPG/Propane to Natural Gas Conversion Kit Burner assembly is removable from the unit as a single Required for field changeover from LPG/Propane to component for ease of service. natural gas. 0 SureLighe Hot Surface Ignitor BLOWER Tough, reliable, long-life, trouble-free performance. 0 Direct drive blower. Silicon nitride ignitor. Statically and dynamically balanced. Cemented to steatite block for protection against current Resiliently mounted. leakage. Blower assembly easily removed for servicing. Ignition leads are constructed of nickel plated copper DC Brushless Motor and are enclosed in high temperature Teflon®insulation High Efficiency Constant Torque. for dependable operation. ® Gas Control Valve ECM (Electronically Commutated Motor). 24 volt redundant combination gas control valve Motor is programmed to provide constant torque at each combines manual shut off switch (On-Off), automatic of the selectable speeds. electric valve (dual) and gas pressure regulation into a Motor is controlled by the Integrated Furnace Control. compact combination control. Blower speeds are easily changed on the integrated 0 Combustion Air Inducer furnace control. See blower performance tables. Shaded pole heavy duty blower prepurges heat exchanger and safely vents flue products. Pressure switch proves blower operation before allowing gas valve to open. Operates only during heating cycle. ML780DFE/Page 3 FEATURES ®CONTROLS Night Service Kit SureLighr Integrated Furnace Control Contains most commonly used service parts: Control contains all necessary controls and relays to • Furnace Control operate furnace. • Ignitor Combustion air inducer is operated by the integrated . Flame sensor furnace control. Prior to ignition, a pre-purge cycle . Gas valve for 15 seconds is initiated.After the main burners are turned off, a post-purge cycle for 5 seconds is run. • Transformer Flame sensor assures safe and reliable operation. Universal Service Kit-Switches Should loss of flame occur the integrated furnace Kit contains: control will initiate 4 re-attempts at ignition before • Primary limits(for each model) locking out unit operation for 60 minutes. • Pressure switches(for each model) Watchguard type circuit automatically resets ignition . Flame rollout switches (for each model) controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. CABINET Fan control consists of adjustable blower timed-off delay Low-profile, narrow width cabinet allows easy (60, 90, 120, 180 seconds-factory setting 90 seconds) installation in downflow applications. and fixed blower timed-on delay(30 seconds-heating, Heavy-gauge, cold rolled steel construction. 2 seconds-cooling). Pre-painted cabinet finish. For air-conditioning applications, blower is automatically energized on thermostat demand for cooling. Control Flanges provided on supply air opening for ease of has low speed continuous blower speed setting for plenum connection or alignment with indoor coil. humidifier or air cleaner operation. ® Insulated cabinet with foil faced insulation on sides and Two accessory terminals furnished for additional back of heating compartment. power supply requirements for 120 volt(less than 1 Sealed blower compartment. Inner blower compartment amp) power humidifiers and powered air cleaners. access panel seals blower compartment from air One addiitonal terminal is furnished for power supply leakage. requirements for 24V(less than 0.5 amp) low voltage Complete service access. accessories. (D Safety interlock switch automatically shuts off power Ignition control has single red LED to indicate status to unit when blower compartment access panel is and as an aid in troubleshooting. removed. Last five codes are stored in non-volatile memory Gas piping and electrical inlets are provided in both (accessible by recall button on control for servicing. sides of cabinet. ® 24 Volt Transformer Coil Match-up Furnished and factory installed on outside of control All furnaces exactly match CR33 cased, downflow box.40VA transformer has fuse wired in series. indoor coils with adaptor rails, furnished with coil. Field Wiring Make-up Box OPTIONS Furnished for line voltage wiring. Downflow Combustible Flooring Base Factory installed internally on left side of furnace. Required for heating only units installed on combustible Box may be installed on right side of furnace. floors. OPTIONS Not required in add-on cooling applications. Blower Relay Kit See Dimension Drawing. (For Use With Two-Stage Outdoor Units) FILTER Allows furnace blower speed changes when matched with two-stage air conditioners or heat pumps. OPTIONS Thermostat Downflow Filter Cabinet Thermostat(programmable/non-programmable) is not Filter cabinet mounts directly on top of furnace. furnished with unit. "A"width cabinet includes one filter. See Thermostat bulletins in Controls Section and "B and"C"width cabinets have two filters. Lennox Price Book for selection. Filter rails are furnished. Front access for servicing. Cleanable filter(s) are furnished. ML180DFE/Page 4 SPECIFICATIONS Gas Model No. ML180DF045E36A ML180DF07OE36B ML180DF09OE48B ML180DF110E60C Heating 'AFUE 80% 80% 80% 80% Performance Input-Btuh 44,000 66,000 88,000 110,000 Output-Btuh 36,000 54,000 72,000 90,000 Temperature rise range-°F 15-45 30-60 30-60 30-60 Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5/10.0 3.5/10.0 Nat. Gas/LPG/Propane High Static-in.w.g. 0.50 0.50 0.50 0.50 Connections Flue connection-in. round 4 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Indoor Wheel nom.dia.x width-in. 10 x 8 10 x 10 10 x 10 11-1/2 x 10 Blower Motor Type DC Brushless DC Brushless DC Brushless DC Brushless Motor output-hp 1/2 1/2 3/4 1 Tons of add-on cooling 1.5-3 1.5-3 2.5-4 3-5 Air Volume Range-cfm 355-1430 430-1475 680-1750 990-2410 Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 6.8 6.8 8.4 10.9 Maximum overcurrent protection 15 15 15 15 Shipping Data lbs.-1 package 113 128 140 160 NOTE-Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE-FURNACES CANNOT BE TWINNED! "A"Width "B"Width "C"Width Models Models Models CABINET ACCESSORIES Downflow Combustible Flooring Base 11M59 11M60 11M61 CONTROLS Blower Relay Kit(for two-stage outdoor units) 85W66 85W66 I 85W66 FILTERS ' Downflow Filter Cabinet 51W06 61W07 61W08 No. and Size of filter-in (1)20 x 20 x 1 (2)20 x 16 x 1 (2)20 x 16 x 1 SERVICE KITS Night Service Kit 84W47 84W47 84W47 Universal Service Kit-Switches 89W19 89W19 89W19 Cleanable polyurethane,frame-type filter. GAS HEAT ACCESSORIES High Altitude Natural Gas to LPG/Propane Natural Gas Input Pressure Switch Kit LPG/Propane Kit to Natural Gas Kit High Altitude p Orifice Kit 0-4500 ft. 4601 -7600 ft. 7601 -10,000 ft. 0-7600 ft. 7501 -10,000 ft. 0-7500 ft. 7501 -10,000 ft. 046 No Change No Change 80W51 70W89 76W15 73W81 73W37 070 No Change 8OW62 80W51 70W89 76WI6 73W81 73W37 090 No Change No Change 80W61 70W89 76W15 73W81 73W37 110 No Change 80W52 80W51 70W89 76W15 73W81 73W37 ML1800FE/Page 5 HIGH ALTITUDE DERATE NOTE-Units may be installed at altitudes up to 4500 ft. above sea level without any modifications. At altitudes above 4500 ft. units must be derated to match information in the shaded areas shown below. NOTE-This is the only permissible derate for these units. Gas Manifold Pressure(Outlet)in.w.g. Line Pressure-in.w.g. Input 0-4500 Feet 4501 -7500 Feet 7501 -10,000 ft. Minimum Natural LPG/ Natural LPG/ ' Natural LPG/ Natural LPG/ Maximum Gas Propane Gas Propane Gas Propane Gas Propane 045 3.5 10 3.5 10 3.5 10 4.5 11 13 070 3.5 10 3.3 10 3.5 10 4.5 11 13 090 3.5 10 3.3 10 3.5 10 4.5 11 13 110 3.5 10 3.3 10 3.5 10 1 4.5 11 13 Natural Gas High Alitude Orifice Kit required. INSTALLATION CLEARANCES Vent Type Type B1 Type C Sides 0 in. (0 mm) ' 0(0) Rear 0 in. (0 mm) 0(0) Top 1 in. (25 mm) 1 (25) Front 2-1/4 in. (57 mm) 2-1/4(57) Front(service/alcove) 24 in. (610 mm) 24(610) Floor 2 Combustible 2 Combustible Flue 1 in. (25 mm) 6(152) NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ANSI-Z223.1). NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable provisions of local building codes. Left side requires 4 in.if single wall vent is used on 14-1/2 in."A"width cabinets,2 in.on 17-1/2 in."B" width cabinets. 3 Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed between furnace and combustible floor.Not required in add-on cooling applications if installed in accordance with local codes,National Fuel Gas Code ANSI-Z223.1 or National Standard of Canada CAN/CSA-B149.1 and CAN/CSA-B149.2 Installation Code for Gas Burning Appliances'. Do not install the furnace directly on carpeting,tile,or other combustible materials other than wood flooring. ML180DFE/Page 6 DIMENSIONS - INCHES(MM) 3-1/8 9 (79) /16(14) D RETURN AIR B OPENING FLUE OUTLET/ (Top) 19-7/16 9/16 (494) (14) 9/16 (14) TOP VIEW A 3/4(19) 27-314 Front Panel (705) B 9/16 19-7/16 (14) (494) 1 .0--9/16 (14) AIR FLOW O ELECTRICAL INLET (Either Side) vvvvvvvvvvvvv 33 • • • • vvvvvvvvvvvvv (638) vvvvvvvvvvvvv vvvvvvvvvvvvv 5-3/8(137)Right GAS PIPING INLET 2-3/16(56)Left (Either Side) vvvvvvvvvvvvv vvvvvvvvvvvvv • vvvvvvvvvvvvv vvvvvvvvvvvvv • • 6-5/8(168)Right 7-1/8(181)Left 3/4 C Supply 3/4 �1 SupplyBPI 3/4 9(19) Air (19) (489)) Air �(i ) FRONT VIEW SIDE VIEW A B C D Model No. in. mm in. mm in. mm in. mm ML180DF045E36A 14-1/2 368 13-3/8 340 13 330 4-3/4 121 ML180DF07OE36B 17-1/2 446 16-3/8 416 16 406 6-1/4 159 ML180DF090E48B ML18ODF11OE60C 21 533 19-7/8 1 505 19-1/2 495 8 203 ML180DFE/Page 7 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) DOWNFLOW FILTER CABINET "A"WIDTH FURNACES "BAND"C"WIDTH FURNACES (Single Filter) (Two Filters) 17-1/2(445)"B"Box 21(533)'C Box 20-1/Z � " '4-1/2 20.1 (521) (388) (521) 21 17-1/2 FILTER(1)�� (533) FILTERS(2) (445) i 0 / 54 / 50-1/2 (1372) ` (1283) 00,/ 33 33 (838) (A3A) FILTER ACCESS DOOR FURNACE FURNACE FILTER ACCESS DOOR NOTE: Return Air Opening(W x D) "A"Box 13-1/2 x 19-5/8(343 x 498) "B"Box 16-1/2 x 19-5/8(419 x 498) "C"Box 20 x 19-5/8(508 x 498) ML180DFE/Page 8 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE 1-1/2 (38) SUPPLY AIR OPENING 19-13/16 21-13/16 DOWN (503) 27-1/4 (554) 1-112 FLOW (692) FURNACE (38) B 1-1/2 n (38) Front Of Furnace - (38)"�40III ' I TOP VIEW SIDE VIEW Cabinet Catalog A B C DOWNFLOW Width Number in. mm in. mm in. mm ICOMBUSTIBLE A 11M69 16-9116 421 13-9116 344 15-3/4 400 I I FLOORING BASE B 11M60 19-9/16 497 16-9/16 421 18-3/4 476 ' FLOOR C 11M61 23-1/16 586 20-1/16 510 1 22-1/4 565 OPENING 22 (559) C� DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS Furnace Width Coil Furnace Coil Overall Model Width Width Height Height Number - in. mm in. mm in. mm in. mm 33 CR33-18A-F 17-1/2 446 14-1/2 368 14-1/8 359 47-1/8 1197 (838) CR33-24A-F 17-1/2 446 14-1/2 368 14-1/8 359 47-1/8 1197 ® Overall CR33-24B-F 17-1/2 446 17-1/2 446 14-1/8 359 47-1/8 1197 Height CR33-30/36A-F 17-1/2 446 14-1/2 368 16-1/8 410 49-1/8 1248 0 CR33-30/36B-F 17-1/2 446 17-1/2 446 16-1/8 410 49-1/8 1248 :;:5.• •'`�: CR33-30/36C-F 21 533 21 533 16-1/8 410 49-1/8 1248 ° 0 CR33-48B-F 21 533 17-1/2 446 20 508 53 1346 • �/ Coil Height CR33-48C-F 21 533 21 533 20 508 53 1346 • � / CR33-50/60C-F 24-1/2 622 21 1 533 23-5/8 600 56-5/8 12276 Coil Width ML180DFE/Page 9 BLOWER DATA ML180DF045E36A PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure -in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1430 285 1215 180 1035 120 995 110 930 100 0.10 1400 285 1175 185 995 130 885 100 850 90 0.20 1375 300 1145 200 950 140 840 110 725 85 0.30 1335 315 1120 210 915 145 790 115 665 95 0.40 1320 325 1075 220 870 155 745 125 625 100 0.50 1275 335 1045 230 835 165 715 135 565 105 0.60 1245 345 1000 235 785 170 655 140 520 115 0.70 1215 355 970 245 745 180 605 150 355 130 0.80 1175 365 925 255 695 185 555 155 400 130 ML18ODF07OE36B PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1475 275 1345 170 1225 135 1185 125 1110 105 0.10 1430 290 1275 175 1190 145 1155 135 1005 95 0.20 1400 295 1230 190 1125 160 1110 150 900 100 0.30 1360 310 1205 205 1085 160 1055 155 845 115 0.40 1310 325 1155 210 1050 175 1000 165 790 115 0.50 1280 335 1110 220 985 185 950 180 705 130 0.60 1250 350 1060 235 935 195 865 185 645 135 0.70 1220 355 1000 245 865 205 815 195 590 140 0.80 1165 365 935 250 795 210 750 200 480 145 ML18ODF09OE48B PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1750 385 1550 265 1430 205 1355 185 1195 130 0.10 1725 390 1495 270 1390 220 1320 195 1145 140 0.20 1695 405 1470 285 1340 235 1280 210 1105 145 0.30 1660 415 1425 300 1290 240 1225 215 1040 160 0.40 1615 --430 -1395--- 310 --1250-- 255 --z30-- 1005- 170 0.50 1570 450 1360 325 1210 265 1145 240 945 180 0.60 1545 465 1295 340 1165 280 1085 255 865 185 0.70 N/A N/A 1265 350 1120 295 1040 265 810 200 0.80 N/A N/A 1215 365 1080 305 1000 275 755 210 ML180DF110E60C PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2410 625 2095 405 1875 295 1700 225 1635 180 0.10 2385 630 2100 415 1830 310 1610 240 1505 190 0.20 2325 650 2010 440 1760 330 1570 255 1375 195 0.30 2280 675 1940 460 1705 340 1500 260 1320 210 0.40 2235 690 1895 475 1635 365 1440 285 1265 225 0.50 2165 710 1845 490 1595 380 1380 300 1200 235 0.60 2125 735 1800 510 1545 390 1320 310 1170 250 0.70 2090 740 1755 530 1510 405 1285 325 1100 260 0.80 2035 760 1700 540 1460 425 1255 345 1030 275 ML180DFE I Page 10 n • REVISIONS Sections Description of Change Dimensions Updated. 001G,V tVi�1J1 SmILM CERTIFIED,, " �`�r►%r REGISTERED �fRTIFiE� ® QUALITY SYSTEMS Visit us at www.lonnox.com L ENNI 71 For the latest technical information,www.lennoxdavenet.com Contact us at 1-8004-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 02012 Lennox Industries,Inc. G'� RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #ML180DF045024 AFUE80% ❑ Heat Pump Model # AFUE HSPE_ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑' Gas Piping ❑ Solid-Fuel Appliance ❑' Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances �CLKQi��?l4Gl2QiG Applicant Signature: '�....�_.�,.... ,.y Date: 02/26/2018 Applicant Printed Name: Jeana Brennan I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 RESIDENTIAL MECHANICAL y� o PERMIT APPLICATION .Cl1v Department of Community& Economic Development City of Arlington • 18201 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:20201 79th Dr NE Project Description:replace furnace like and kind Owner: Russ Patrick Address: 20201 79th Dr NE City:Arlington State'.WA Zip Code: 98223 Phone: 4252053845 Email:russpatrick@live.com Applicant: Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville StateWA Zip Code: 98270 Phone: 360-658-9500 Email: info@paragonheating.com CONTRACTOR INFORMATION Contractor Name:Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville StateM Zip Code: 98270 License Number:PARAGHC8632A Expiration: 5/1/18 Phone:360-658-9500 Email:info@paragonheating.com k i7l vr-V STAFF USE ON Y l Permit # 7i Accepted by: / Dater �0 1 6/16LP Page 1 of 2 Permit#: 1842 Permit Date: 03/02/18 Permit Type: RESIDENTIAL MECHANICAL Project Nam e Patrick Applicant Nam a Paragon Heating and Horn eCom brt Solutions Applicant Address: PO Box 798 Applicant, City, State, Zip: Marysville,WA98270 Contact: Jeana Brennan Phone: 360-658-9500 Em al: info@paragonheating.com Scope of Work: Replace Gas Furnace Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 03/05/2018 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wner Nam e Caner Phone Zoning 00825900000700 2 0201 79TH DR NE PATRICK RUSSELL 111 Single Fam iy G&DEBBIE L Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# Paragon Heating J eana Brennan 3 60-658-9500 P .O.Box 798 CONSTRUCTION UBI 603 395 569 CONTRACTOR Paragon Heating J eana Brennan 3 60-658-9500 P O.Box 798 CONSTRUCTION Labor CONTRACTOR Industries&PARAGHC8632A Fees Fee D escription N otes A m cant Forced Air Heat f ee per Btu $ 25.00 Mechanical Base P erm i Fee $ 25.00 Processing/Technology $25.00 Total $ 75.00 Attached Letters Date Letter D escription 03/02/2018 Building Perm t Paym Bits Date Paid By D escription P aym art Type A ccepted By A m aunt 03/05/2018 Jeana Brennan 6 8828278 c c $75.00 O itstanding Balance $0.00 Notes Date Note C reated By: 03/02/2018 Model#M L180DFE AFUE 80%K ristin Foster 03/02/2018 Out of city has expired.Em al sent to renew. K ristin Foster Uploaded Files Date File Nam e 03/06/2018 3128910-1842 Issued Perm i.pdf 03/05/2018 3127342-1842 3-2-2018 Revised Specs.pdf 03/02/2018 3120646-1842 Application.pdf 03/02/2018 3120645-1842 Specs.pdf