Loading...
HomeMy WebLinkAbout9032 168th Street NE_BLD1721_2026 IN °r RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 ll�vc'� THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9032 168th Street NE Plat: Gregory Park Lot 7 41 Single-family ❑ Duplex ❑ Townhouse al Addition Ij Accessory structure Proposed Area: Il s' Floor: 703 2"d Floor: 920 Garage: 370 Total SF: 1993 Describe Proposal (include cross street): Application for new single family residence to be located at 9029 168th Street NE. Cross street is 91st Valuation: 74� S�� • !�� owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State: WA Zip Code:98223 _ Phone: (425) 785-0797 Email:Matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 _ _ Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 6/16LP Page 1 of 3 �` °� RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development �� ! O� City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) hJl Bath/Shower Combo (4.0) x 1 6 Sink (1.5) x 1 I� Shower(2.0) x 1 Lavatory (1.0) x 3 Q Clothes Washer (4.0) x Water Closet(2.5) x 3 EJi Dishwasher (1.5) x 1 [jl Water Heater x 1 Q! Hose Bibb (2.5) x 2 Water Heater Model # V1; Other(list) x 1 AO Smith HPTU-50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: AB Proposed Piping Material: PEX Proposed DWV Size: 2" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 `�� RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development O� City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 N Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: Bryant 915SA30040514 95% Furnace (80+) Model# AFUE E311 Heat Pump Model# SEER HSPE AC Unit Model# SEER 0i Type II Hood ❑ Commercial Cooking Appliance Q Hydronic Piping Boiler ❑ Solid-Fuel Appliance a1 PV System ❑ Fireplace Insert ❑ Outdoor BBQ Storage Tank �l Freestanding Stove WJ! Gas Piping Other Gas Piping Information Not Applicable: ❑ Black Steel Pipe Material: _ Pipe Size: 1' Total BTU's of all Appliances: 120,000 Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: 6/16LP Page 3 of 3 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360)403-3551 BUILDING PERMIT Address:9032 168th Street NE Permit#:1721 Parcel#:01166900000700 Valuation:205501.85 OWNER APPLICANT CONTRACTOR Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC Address: 1450 LAKE ROBBINS DR STE 430 Address:9028 168th Street NE Address: 11410 NE 124th Street,Ste#103 City,State Zip:THE WOODLANDS,TX 77380 City,State Zip:Arlingotn,WA 98223 City,State Zip:Kirkland,WA 98034 Phone: Phone:425-785-0797 Phone:360-353-0588 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Single Family Residence CODE YEAR: 2015 STORIES: 2 CONST.TYPE: V-$ DWELLING UNITS: 1 OCC GROUP: R-3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCI I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of rlin # 01. � ► 1 - -I�7 r-, Signature Print Name Date Released By Dde CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/14/2017 Building Permit Fee $2,220.14 11/14/2017 Building Permit Fee $31.72 11/14/2017 Building Plan Review Fee $1,443.09 11/14/2017 Building Plan Review Fee $20.62 11/14/2017 Furnace $25.00 11/14/2017 Gas Outlets Base Fee 1 to 5 $10.00 11/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00 11/14/2017 Mechanical Permit Base Fee $25.00 11/14/2017 Park-Community SF $1,662.00 11/14/2017 Plumbing Permit Fee(Enter Fixture Fee) $156.00 11/14/2017 Processing/Technology Fee $25.00 11/14/2017 State Building Code Surcharge Fee $4.50 11/14/2017 Traffic Mitigation-City $3,355 00 11/14/2017 Water Heater $25.00 Total Due: $9,028.07 Total Payment: $9,028.07 Balance Due: $0.00 CALL FOR INSPECTIONS BALDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �`��` °F RESIDENTIAL PERMIT APPLICATION t Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9032 168th Street Plat: NE Gregory Park Lot 7 41 Single-family ❑ Duplex ❑ Townhouse Addition Accessory structure Proposed Area: 151 Floor: 703 2"d Floor: 920 Garage: 370 Total SF: 1993 Describe Proposal (include cross street): Application for new single family residence to be located at 9029 168th Street NE. Cross street is 91st Valuation: S�� • !�� owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 _ Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State: WA Zip Code:98223 _ Phone: (425) 785-0797 Email:Matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 _ _ Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Contact Person. Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 6116LP Page 1 of 3 °�' RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) F�]1 Bath/Shower Combo (4.0) x 1 (' j Sink (1.5) x 1 �I Shower (2.0) x 1 ej Lavatory (1.0) x 3 ❑I Clothes Washer (4.0) x Water Closet(2.5) x 3 F�l Dishwasher (1.5) x 1 Water Heater x 1 Hose Bibb (2.5) x 2 Water Heater Model # Other (list) x 1 AO Smith HPTU-50N Plumbing Section Continued Proposed Water Piping Size: 3/411_ Proposed DWV Material: ABS Proposed Piping Material: PEX Proposed DWV Size: 211 • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 6�'�` RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development �l! O City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: I Furnace (80+) Model# Bryant 915SA30040514 AFUE 95% Heat Pump Model# SEER HSPE 01 AC Unit Model# SEER Type II Hood ❑ Commercial Cooking Appliance D Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Storage Tank �I Freestanding Stove ❑ Gas Piping Other Gas Piping Information Not Applicable: p Black Steel Pipe Material: Pipe Size: 1" Total BTU's of all Appliances: 120,000 Distance from Meter to Furthest Appliance: . 5 • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: I Print Applicants Name: AI h 6116LP Page 3 of 3 SETBACKS NOTES: B'wA7>�R 1 8TH ST° NE, FRaVT 20' .BUILDING DIIIEN-96Yff ARE 70 ME 5' FAOE OF FOUNDA776YV 2f00 REAR 5' -MADING 9YONN AS DE26W _ 1 ACTUAL LOICAAOW MAY VARY B MER •2OI°E DR/VEWAY 70 PUBLIC ROAD 10.00'PUBLIC •-X T fEXT TO BE INSTALLED PER U77LITY WA7D? CITY OF ARL/NGTLW'S STANDARD EA T SERNQ� i,l —— •ALT FENCE lO BE INSTALLED GW I G?AD1DVT SJDE OF BUILDING PMM s Y v v Dp p v :0920'49CNON"W I MRANX TO BE INSTALLED PER CITY Of' S7wm(XtmouT. �70 23.°38 ��� ��� I I ARLINGTWW STANDARDS �`90 COWN£CT Roar AND S` �� o•�, STORM NOTES.• FOIOANG DRAINS wAY a cs --' : ( � •7FSL'INSTALLED PR/64 lt7 g } q0, 2900' o o .L` CGWS1RUCAM J� 8.w° ( •BARE SOLS COWED N17H MULOW s OR ANOTHEIP APPROVED EG/P •TOPSOIL PER ME BAIP T5.13 CGNNEC A6V \ l 18.60 11.50 I I (EFF 12'DEPTH) •ALL OWS/7E RUNOFF 0NNECTED 70 GARAGE 2.00 I S •XF 9YALL BE STABILIZED PRIOR BU PEILDING a TO BUILDING MIT BEING al7L/NE FINALIZED g I i SITE NOTES.- PROPO.SM R£STmar •7761/TL/NE FOOANG DRAINS AND ROOD DRAINS 70 PERI/ANENT 100.ROOF CYPRESS-1623 I i I STt�4A/DRA/NAX SY57LV POP MRHANG I 1 GARAGE R/GYIT APPROVED PLAT DRAINAGE PLAN 1,2651,7 W I aV FILE W7H AIE MINTY. 5 00'i / I 30.00 13 , ' ° 4 Z Ij AREA OF D/S7UR54N6E/NGYUDES ENAR£LOT. r I TPA;70 12 SF h Q I I LEGEND: � I LOT 7 0 °� \ I �— BLOW OFF I ® WATER MM? �O I 4( FIRE HYDRANT o I EXISANG ° I I AIR VAC = I COMM(TIP.) ® (:AICl/BASIN FJ➢VI9ym ` I O OYEANOIUT CWTOU�(rip 5.00'BSBL 474 a K I ( O AIANHOif BLOa( WALL 7Rff REMOVAL 2.00'AbOlAGWAL I I ROW"CA AAN I =:t:9 orsf'voc 76 N£CITY I I g 2M Q`�ARLING7(W ) 17 W S A7'BSl4L 1 ° X&F 1'=20' ¢88 •, ; LOT 7 PRGpERTY N897005"w J> SITE PLAN ' CaNER(7W.) GREGOR Y PARK L G/ HOMES PLAN NO. CYP.—1623 LOT AREA = 6,101 SF DATE 101212017 PARCEL # LOT 7 HOUSE= 1,265 SF 1471 I NE 29rh Place,#I07 DRIVEWAY= 405 SF Bellevue,Washington 98007 DESIGNED CORE ADDRESS 9032 1687H Sr NE 425.885.7877 Fax 425.085.7963 WALKWAY/PAAO = 12 SF PROJECT NUMBER TOTAL= 1,682•SF ENGINEERING PLANNING • SURVEYING DRAWN CAF 13024L-GRG00 ,1A,/®rm , CITY OF ARLINGTON 238 N. OLYMPIC AVEARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:9032 168th Street NE Permit#:1721 Parcel#:01166900000700 Valuation:205501.85 OWNER APPLICANT CONTRACTOR Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC Address: 1450 LAKE ROBBINS DR STE 430 Address:9028 168th Street NE Address: 11410 NE 124th Street,Ste#103 City,State Zip:THE WOODLANDS,TX 77380 City,State Zip:Arlingotn,WA 98223 City,State Zip:Kirkland,WA 98034 Phone: Phone:425-785-0797 Phone:360-353-0588 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Single Family Residence CODE YEAR: 2015 STORIES: 2 CONST.TYPE: `I-$ DWELLING UNITS: 1 OCC GROUP: R-3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RC W 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE,:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of rlin Signature Print Name Date Released By Dik CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED-THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/14/2017 Building Permit Fee $2,220.14 11/14/2017 Building Permit Fee $31.72 11/14/2017 Building Plan Review Fee $1,443.09 11/14/2017 Building Plan Review Fee $20.62 11/14/2017 Furnace $25.00 11/14/2017 Gas Outlets Base Fee 1 to 5 $10.00 11/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00 11/14/2017 Mechanical Permit Base Fee $25.00 11/14/2017 Park-Community SF $1,662.00 11/14/2017 Plumbing Permit Fee(Enter Fixture Fee) $156.00 11/14/2017 Processing/Technology Fee $25.00 11/14/2017 State Building Code Surcharge Fee $4.50 11/14/2017 Traffic Mitigation-City $3,355.00 11/14/2017 Water Heater $25.00 Total Due: $9,028.07 Total Payment: $9.028.07 Balance Duc: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling;for an inspection please leave the following;information: Permit Number,Type of Inspection being.requested,and%shether you prefer morning or afternoon LINGTONropy BUIL IN pEPaR � 'SE7'�ACKS 1 S NOTES.- fRGWT 20 .SUILOVNG OVMENZWS ARE 7O WE 5' FAX OF FOUNDAnO4/ 2t RFUP 5' •6R4blWG SHOW AS DEY6W j A0711AL LOCAnLW mAY VARY 8 •.2WE DWWWAY 7O PUBUC ROAD NO C •.A'LT our TO BE INSTALLED PER UNLE S AVMWVE Y T aTY OF ARL/NGXW S STANDARD Il p T� IF—— •-71 r fEW TO BE INSTALLED OW D p y 9 I 6R4UENT.9X OIL 8U/LUNG PARQ4 _ N8920'49"W d :I •CVWS7AV0aV EMIR a� m BE INSTALLED PER 07Y OY- ISIOYPM GYEANGI/T. 2 U8 ���``� I I ARUNG7MNS STANDARDS COWNECT Roar AND S�' �P�o`Q STORM NOTES.• F00AWG DRAINS SAY a ?`r o?-' I •OY�W87RUC LM PRIa? TO $ OO' 2Q O0' ` o00 >` all •BARE SMS COWRED W7H MULOV a?ANOn/ER APWOIkW BMP •7OWSLLL PER WMOE BMP M 13 — — Sew 500 \ 11.50 &T 12-DIP 7H OLWNECn 1850 ON I •ALL ONS/7E R NOfF COWNECIED TO GMRAX 200 g PR/VA7E S7O4M SA18 BUILDING I •.97E SMALL BE STABILIZED AWOR aflZINE g I I TO BUILDING PmlrBONG AW4UZED SITE NOTES.- PROP 0SM RE9,DOVQE •NOWL/NE f00hWG ATA/NS AND ROOF R0 DRAINS TO MWANENT 1.010'RWr CYPRESS-1623 I I SMW DRAINAGE S6MV P& OVERHANG I GARAGE RIGHT a APPROVED PLAT DRAINAGE PLAN 1,2W9r W I ON RLE W7H ME CWNTY. 500' 30.010 ° Z I, •AREA OF D/SAIRBANOIE INCLUDES 1J38 / - DV1RE LOr. i I � >:W i Llh ( 1 PAW 12 SF I I LEGEND. nor 7 W07ER MEU ARE HYDRANT o I D#S71NG AIR VAC = I (CaWWR(nP.) CATI,M BA9N RN/SAQED 1, I O Ol'.EANGY/T (�� I 500 B519L 474 I I O MANHOLE I I I ® &Off WALL MEE REMOVAL F I 2.00'ADDVAO AL —Row"CA Am _ +. I I 717, nIE aTY I of ARUNG7GN ,K XWE I'm 20' i 48J8 LOT 7 PROPERTY 1V8970'05"W ' SITE PLAN C15WER(nP.) GREGOR Y RA RK LGI HOMES PLAN NO. CYR—1623 LOT AREA = 6,101 SF DATE 101212017 PARCEL # LOT 7 HOUSE= 1,265 SF 47I 1 NE 29M Vlo e,#101 DRIVEWAY= 405 SF Bel--,Wahmgfo 98007 DESIGNED CORE ADDRESS 902 188M ST. NE 415.885.7877 FaR 425.885.7963 WALKWAYIPAn0 = 12 SF `DESIGN PROJECT NUMBER TOTAL= 1,682 SF ENGINEERING • PLANNING • SURVEYING DRAWN CAF 13024L-GRGOO i l r ; ax 7 Y;V Permit Information Date 11/1/2017 Permit Number 1721 Project Name Gregory Park Applicant Name LGI Homes-Washington,LLC Applicant Address 9028 168th Street NE City,State,Zip Arlingotn,WA 98223 Contact Matt Adams Phone 425-785-0797 Email matt.adams@lgihomes.com Permit Type Single Family Residence Site Address 9032 168th Street NE Valuation 205501.85 Status Applied Permit Issued Permit Expires Square Feet 1993 Type of Construction/Occupancy Load V-B Number of Stories 2 Proposed Use New SFR Assigned To Kristin Foster Property Owner Parcel Address Legal I Owner Phone Zoning 01166900000700 9032 168th Street LGI HOMES-WASHINGTON 111 Single Family Residence- NE LLC Detached Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type LLCHomes-Washington, :360-Jake Jabusch 0588 3- ake.jabusch@lgihomes.comCONTRACTOR IIndusLabo and I-GIHOHL857M I_LC c)588 Ilndustries Review Date Type Description I Target Date Completed Date IAssigned To Status 11/1/2017 lResidential Dwelling 11/8/2017 1\my Rusk o In Review 11/1/2017 lResidential Dwelling 11/8/2017 lKevin Olander Iln Review Fees Fee Description Notes Amount Building Permit Fee 322.10.00.01 $2,220.14 Building Permit Fee 322.10.00.00 $31.72 Building Plan Review Fee 345.83.00.00 $1,443.09 Building Plan Review Fee 345.83.00.00 $20.62 Furna2d322.10.00.00 $25.0 Gas Outlets Base Fee 1 to 5 322.10.00.00 $10.00 Mechanical Fee Enter Fixture Fee 322.10.00.00 $25.00 Mechanical Permit Base Fed322.10.00.00 $25.00 Park-Community SF 345.85.00.00 $1,662.00 Plumbing Permit Fee Enter Fixture Fee 322.10.00.0 13 @$12 $156.0 Processing/Technology Fee 341.43.00.02 $25.00 State Building Code Surcharge Fe 386.00.01.00 $4.50 Traffic Mitigation-City 345,85.00.02 $3,355.00 Water Heater 322.10.00.00 $25.00 Total $9,028.07 Payments Date Paid By Amount Description I Payment Type Acce ted B 11/1/2017 JILGI Homes-Washington LLC $1.443.0 Check#5719 jKristin Foster 11/1/2017 ILGI Homes-Washington LLC $7,532.64 IGheck#5720 Kristin Foster Total $8.975.73 Amount Outstanding:$52.34 Uploaded Files Upload File Date File Uploaded B 11/2/2017 11:07:07 AM 1721 Site Plan.pdf Foster,Kristin 11/2/2017 11:07:07 AM 1721 Application.pdf Foster,Kristin x i RESIDENTIAL PERMIT APPLICATION 'y l_ Department of Community& Economic Development iV City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 C+`� THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9032 168th Street NE Plat: Gregory Park Lot 7 _ R3 Single-family ❑ Duplex Townhouse OI Addition Q' Accessory structure Proposed Area: 1 s' Floor. 703 2"d Floor: 920 Garage: 370 Total SF: 1993 Describe Proposal (include cross street): Application for new single family residence to be located at 9029 168th Street NE. Cross street is 91st Valuation: l C 'A Owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State: WA Zip Code:98223 Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 Phone: (425) 785-0797 Email: Matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 606LP Page 1 of 3 � I 1 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) t3 Bath/Shower Combo (4.0) x 1 C11 Sink (1.5) x 1 41 Shower (2.0) x 1 41 Lavatory (1.0) x 3 ❑ Clothes Washer (4.0) x [ Water Closet(2.5) x 3 Dishwasher (1.5) x 1 Water Heater x 1 QI Hose Bibb (2.5) x 2 Water Heater Model # R3 Other(list) x 1 AO Smith HPTU-50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: ABS Proposed Piping Material: PEX Proposed DWV Size: 2" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6116LP Page 2 of 3 n I RESIDENTIAL PERMIT APPLICATION ' Department of Community & Economic Development Y INT O City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: Bryant 915SA30040514 95% Furnace (80+) Model# AFUE ❑1 Heat Pump Model# SEER HSPE Ol AC Unit Model# SEER ❑ Type II Hood ❑1 Commercial Cooking Appliance ❑ Hydronic Piping J Boiler Solid-Fuel Appliance ❑ PV System 01 Fireplace Insert Outdoor BBQ ❑ Storage Tank Freestanding Stove Q! Gas Piping ❑ Other Gas Piping Information Not Applicable: ❑ Black Steel Pipe Material: Pipe Size: 1 Total BTU's of all Appliances: 120,000 Distance from Meter to Furthest Appliance: 5 • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: ' 6/16LP Page 3 of 3 7-00.00 14-02-00 15-10-00 ® F - Al w c O1 00 00 4-00 00 °tt TR°R PLU G SHOWER PLUMBING MBING 'O O � n N p—��••QyYVO DD X 1 tO il4Na � O O O N N W ® C2 O N O O QO N T PLUMBING O �i O 9 F3 v y C I v IA (fr (A o o ov 3 a 0 34 -00-00 17-00-00 A5 20-00-00 15-00-00 y� 4)w p- C II t7" ��rypC7 zYd�7C� ; dam[;gz z O rx�rx��> k �Op��7O C � o t:O Den 0-y—Dmigmr Nl MYMn LGI HOM ES ]ab Number Sheet Tltla 6MDI 1'00Yfin—K l ErMed nA("I Job Name/Model 1623 FL GR a6sK r2S7�Y0d DeelOner DAN C. TRU66 LAYOUT Address: {nfoo41 PO.1{:_w I w M.0.4ft mWN! Dne 5/1/201] MiTek MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Re: 1623-FL Fax 916/676-1909 LGI HOMES 1623-FL dcc The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by BMC West-Everett,WA. Pages or sheets covered by this seal: R50439568 thru R50439583 My license renewal date for the state of Washington is May 16,2019. ov,mLL & o��woc WAS�.,�c� � R 51398 q� �CISTgR� • 8! May 2,2017 Baxter, David IMPORTANT NOTE:Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. i Job Truss Trus..,ype Qry Ply LGI H. .�5 1623-FL dcc R50439568 1623-FL Al GABLE 1 1 Job Reference(optional) _ BMC, EVERETT,WA 98205-3212 8 010 s Apr 20 2016 MITek Industries,Inc. Mon May 01 22:35:11 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-FntkSATrg1 GQ?5thZZ9PGSsrFpl?eC7VmLG17DzKk6E 0-1�8 0-A8 Scale=1:25.4 A B C D E F G H I J K L M A QqAD AA AC Z Y X W V U T S R Q P 0 N r 1- 4-0 13-4 0 1 4 8 0 11 5 9.12 i i-4.0 1.4-0 r 1-4-D 1-4-0 14——0—1.4-0 1.4-0 i-4-0 1 - 1-4•0 1•t-12 Plate Offsets(X,Y)— IA:Ed11e,0.0-121.IAA:0-1-8,0.0-12L[AB:O-I-B.0-0-121,[AC:0-1-8.0.0-121.[AD:0-1-8,0-0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/defl L/d PLATES GRIP TCLL 400 Plate Grip DOL 1.00 TC 0.07 Vert(LL) n/a n/a 999 MT20 1851148 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 00 Rep Stress Incr YES WB 0.02 Horz(CT) 0.00 N n/a n/a BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:57 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing OTHERS 2x4 HF No.2(flat) REACTIONS. All bearings 15-9-12. (lb)- Max Grav All reactions 250 Ib or less at joint(s)Z,N,Y,X,W,V,U,T,S,R,Q,P,0 FORCES. (lb)-Max.Comp/Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 5)Gable studs spaced at 1-4-0 oc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��L 6 WASI�M wO� 51398 k4 NAL LNG May 2,2017 ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1I1.7473 rev.10/03/2015 BEFORE USE. Design vadd for use onty with MITek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss systortt Befere use,the building designer must verity the applicability of design parameters and property incorporate this design Into the overall buduiuy deayu.Bwuuy indivalud le lu pi uvmd bucAMny ul mdlviduul hula web und/ot dtmd manibres unly Adddimtal Ieutputarq and permanent b acing Mlle k is always required for stability and to pravem collapse with possible personal injury and property damage.For general guidance regarding the (edification.storage,delivery,erection and bracing of ttusses and twos systems,see ANSlrrPl1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Tessa Plate Institute,218 N.Lee Street.Sued 312,Alexandria,VA 22314. Suite 109 Citr H i 1 A 95610 Job Truss Tres,..ype Qty rPlyTLGh. .a- 1823FL dcc R50439569 1623-FL A2 Floor 4 ef Vona sli EVERETT,WA 982C 3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:12 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-jzR6g WUTbLPGcFSt7GgepfOvyDwPNbhe??OaffzKk6D 0-1-8 H 1 2'8'D � �i 1 i 1-3-0 ,0�8 S=1:25.7 3x6= 3x4 = 3x6= 4x5 = A B C D E F G H P 0 0 M L K J t 3x6 = 3x10 = 3x4 = 4xB= I 15.9.12 154-12 Plate Offsets(X,Y)— IA:Edge,00.0-112,-[D:0-1-8,Edge1,fH:0.1-8,Edge,fK:0.1-8.Edge1 fO:0-1-8 OA-12) (P:0-1-8 0-0-121 10:0-1-8 0-0-121 (R:0-1.8.M-121 LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL) -0.16 L-M >999 480 MT20 185/148 TCDL 100 Lumber DOL 1.00 BC 0.77 Vert(CT) -0.21 L-M >896 360 BCLL 0.0 Rep Stress Incr YES WB 0.32 Horz(CT) 0.04 1 n/a n/a BCDL 5.0 Code IRC2015ITP12014 Matrix-R Weight:65 lb FT=O%F,12%E LUMBER- BRACING. TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=849/0-3-6,N=849/0-5-6 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD H-1=-851/0,B-C=-2172/0,C-D=-2172/0,D-E=2376/0,E-F=-2376/0,F-G=-813/0,G-H=813/0 BOT CHORD M-N=0/1350,L-M=0/2376,K-L=0/2376,J-K=0/1840 WEBS B-N=-153210,B-M=0/933,C-M=-297/0,D-M=467/86,H-J=0/1150,F-J=-1166/0,F-K=0/706 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. BRILL Gf WAskiy "� 51398 �rAr 0'nF �crs�� SSIONAL May 2,2017 AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.1010312015 BEFORE USE. Design valid for use only with M1TekAD connectors.This design is based only upon parameters shown,and is for an Individual building componom not a truss system,Before use,the building designer must verity the applicability of design parameters and properly Incorporate this design Into tho overall 11 building design,Gracing indicated is to prevent buckling of individual truaa d/web and/or chord members only. fWtd Aonal temporary and permanent bracing Mire i� Is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the fabric lion,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Institute.218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heiahts.CA 95610 E1621-FL Truss Ttusa.type Qty Ply LGI H...,'S 1623-FL dcc R50439570 A3 Floor 2 1 Job Reference o tional BMC, EVERETT,WA 98205-3212 6,010 s Apr 20 2016 NTek Indiusbies,Inc. Mon May 01 22:35:12 2017 Page 1 ID:IgublkbWR27z3USE92FUkDxKpFM-jzR60WUTbLPGcFSt7GgWov_DwUhlble470aKzKk6 D 0-1-8 L 1�FqScale=1:27.2 1.5x4 I L5x4 = 1.5x4 = 3x6= 1.5x4 II 3x4 = 1.5x4 II 3x6 = 3x4 II 4x6 II A B C D E F G H m M L K J I 3x6 = 3x10= 1.5x4 II 3x4= 4x6= 1.5x4 II 15.6.8 15$-8 Plate Offsets(X Y)— [A:Edoe 0.0-121 ID:0-1-8 Edge) 111-1:0-3-0 Edge[ [K:0-1 8 Edael [0'0.1-8 0.0-121 [P'0.1-8 0-0.12) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL) -0,16 L-M >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1 00 BC 0.76 Vert(CT) -0.20 L-M >908 360 BCLL 00 Rep Stress Incr YES WB 0.31 Horz(CT) 0.01 H n/a n/a BCDL 50 Code IRC2015/TPI2014 Matr,x-R Weight:66 lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) H=841/0-3-0,N=841/0-5.8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-2142/0,C-D=-2142/0,D-E=-2329/0,E-F=-2329/0,F-G=-749/0,G-H=-750/0 BOT CHORD M-N=0/1335,L-M=0/2329,K-L=0/2329,J-K=0/1778 WEBS B-N=-1515/0,B-M=0/916,C-M=-297/0,H-J=0/1086,F-J=-1168/0,F-K=0/712,D-M=-449/96 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5)CAUTION,Do not erect truss backwards. O � 51398 �4 R�cis1�R� �,<v SSrdNALE�C� May 2,2017 ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTeK®connectors.This design Is based only upon parameters shown,and Is for an individual building component,not a truss system.Before use,the building designer must verity the applicability of design parameters and property incorporate this design Into the overall bulldkty design. Bracing indicated is to pieveia bualuly ur individual buss web and/up Ohuld li-116 s wily.Adddiund lainpureiy mid peuilaneul Uruting M iTc i� ,s always required for slaWlity and to prevent ca8apse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIRPI7 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate institute,218 N,Lee Street.Suite 312,Alexandria,VA 22314. Suite 109 Cilrua Heights CA 95610 E: w � Job Truss Truso ,pit [Qly PIy LGI F. S 1623 FL dcc R50439571 1623-FL A4r 1 Job Reference_(opUonal) BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:13 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-89?UtsV5MFX7EPI3hzBtMtx2UdDw61FoDfl7C5zKk6C 0-1-8 H 2.6-o I 1i Scale=1:24.9 1.5x4 1.5x4 = 1.5x4 = 3x6 = 1.5x4 II 3x4= 1.5x4 11 3x6= 1.5x4 A B C D E F G 0 K J 13x6 = 3x6= 3x10= 1.5x4 II 3x6 = L 14-9.0 14-9.0 Plate Offsets(X,Y)— IA:Edae.0-0-121,fD:0-1-8 Edael f1:0-1-8.EdAe1 IM:0-1-8 0-0-121 IN:0-1-8,0.0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TIC 0.66 Vert(LL) -0.22 J-K >784 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.94 Vert(CT) -0.28 J-K >628 360 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(CT) 0.04 H n/a n/a BCDL 5.0 Code IRC2015ITP12014 Matrix-R Weight:59lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: REACTIONS. (Ili/size) L=798/0-5-6,H=798l0-2-10 2-2-0 oc bracing:J-K. FORCES. (lb)-Max.Comp/Max.Ten.-All farces 250(lb)or less except when shown. TOP CHORD B-C=-1993/0,C-D=1993/0,D-E=-2028/0,E-F=-2028/0 BOT CHORD K-L=0/1254,J-K=0/2028,I-J=0/2028,H-1=0/1260 WEBS B-L=-1424/0,B-K=0/838,C-K=-320/0,D-K=348/189,F-H=-1430/0,F-1=0/891,E-1=-293/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)H. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. Sj1E�LL 6 WASH 51398 q, s'S�ONAL� G May 2,2017 ®WARNING.Verify design parameters and READ NOTES ON THIS AND INCLUDED MI TEK REFERENCE PAGE MII.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an indlvidual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and proporly incorporate this design Into the overall 11 [wilding design, Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M iTeiC is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and tout systems,see ANSIfTPM Quality criteria,058.39 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute.218 N.Lee Street.Suite 312,Alexandria,VA 22314, suite 109 Cilrys HeiatI CA 95610 ♦� j I Job Truss Trua_ ype qry Ply LGI I-. :S 1823 FL dcc R50439572 1623-FL A5 GABLE 1 1 Job Reference _(op8onalZ BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTak Industries,Inc, Mon May 01 22:35:14 2017 Page 1 10:lgubikbW R27z3UBE92FUkDzKpFM-IMZs5C Wj7yl_sYCGFhjSu4UMO0nfrYrx$JVhkYzKkBB 0-P6 Scale=1:23.6 A B C D E F G H I J K L Z - 0 LILI. `y Y X W V U T S R O P O N M 1� 0 1 2&0 I 4.0.0 5 4-0 6 8-0 6-0 0 9-4-0 19:10 12A-0 13-4 0 14-9-0 14-0 1-4.0_ 1-4.0 r 1.1-0 1-0-0 1 11i-0 1-0-0 1.4.0 IA-0 15A Plate OHsets(X,Y)— [A:Edoe.0-0-121.�:0.1.8 0.0.121 [Z:0-1-8 0-D-121 LOADING (psf) SPACING- 2-0-0 CSI. THorz(CT) FL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.07rt(LL) n/a n/a 999 MT20 185/148 TCDL 100 Lumber DOL 1.00 BC 0.01rt(CT) n/a n/a 999 BCLL 0 0 Rep Stress Incr YES WB 0.02 0.00 M n/a n/a BCDL 50 Code IRC2015/TP12014 Matrix-R Weight:53lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2(flat) REACTIONS. All bearings 14-9-0. (lb)- Max Grav All reactions 2501b or less at joint(s)X,M,W,V,U,T,S,R,Q,P,O,N FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i e.diagonal web). 5)Gable studs spaced at 1-4-0 oc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. J19 O�WASkr�P�t�,� fl AAp �51398� q7� GIS I ER SSr�NAL ECG May 2,2017 ®WARNING-Verify des/gn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTekO connectors.This design is based only upon parameters shown,and is for an individual budding Component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design.Bracing Indicated is to prevent buckling of individual truss web andior chord members only.Additional temporary aria permanent bracing is i l^r e�< is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delnery.erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback lane safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria.VA 22314. suite 109 Citrus Het hts QA 9561 .: I Job Truss Tru. _lie pry �PTIyLGIRt S 1623-FL dccR1623-FL 61 Floor 2 eference o tiona BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries.Inc. Mon May 01 22:35:14 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-fMZs5C Wj7yt_sYcGFh16u4UFiOc_tUYxSJVhkYzKkeS 0-1-8 H 1 24 r 1-2-13 1-3-0 I 2-4-5 1-1-8 0�pq Scale=1:25.7 1.5x4 I I 1.5x4 = 1,5x4 = 3x6= 1.5x4 II 1.5x4 II 3x4 = 3x4 II 4x6 II A B C D E F 3x6= G H ` W M L K J I 3x6 = 3x6= 3x4 = 3x6= 4x8 = 1.5x4 II 1 1444 10.8-10 3-11-10 Plate Offsets(X.Y1— [A:Edge 0-0-121,111,11:04AEdgel.111-:0.1-S.Edaei,MO.1-8.Edoe1 [0:0.14 0.0-12) [P'0-1-8 0.0-12) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.57 Vert(LL) -0.18 K-L >957 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.69 Vert(CT) -0.32 K-L >543 360 BCLL 0.0 Rep Stress Incr YES WB 0.29 Horz(CT) 401 H n/a n/a BCDL 5.0 Code IRC2015ITP12014 Matrix-R Weight:67lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat)*Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. F-K:4x6 DF No.2&BTR G(flat) REACTIONS. (lb/size) H=794/0-3-0,N=794/0-5-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-1997/0,C-D=-1997/0,D-E=-1997/0,E-F=-1700/0,F-G=699/0,G-H=-700/0 BOT CHORD M-N=0/1251,L-M=0/1997,K-L=0/2088,J-K=0/1700 WEBS B-M=0/859,C-M=-309/0,B-N=-1420/0,H-J=0/1013,F-J=-1128/0,E-K=434/0, E-L=-296/211 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to Increase plate sizes to account for these factors. 3)A plate rating reduction of 20%has been applied for the green lumber members. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6)CAUTION,Do not erect truss backwards. RRI`L 4& ' J� Of WASI� .`7') o� 51398 4� o� ts �SStONAL��� May 2,2017 WARNING-Verr/y,design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7472 rev.10/02/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design.Bracing indicated is to prevent bucking of Individual truss web and/or chord members only.Additional temporary and permanent bracing Mi iT ek' is always required for stability and to prevent collapse with possible personal Injury and property damage.For general guidance regarding the fabrication.storage,delivery,erection and bracing of trusses and truss systems,see ANSUTPH Quality Criteria,OSB49 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lod Street,Suite 312.Alexandria,VA 22314. Suits 109 Citrus H I t A 956f0 Job Truss Tt /pe Qty Ply LGI cS 1623 FL dcc R50439574 1623-FL B2 Floor Girder 2 1 Job Reference o 6onal BMC, EVERETT,WA 98205.3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:15 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-7Y7FIXWLuGnrTiASoOELRIOJcQwdavY5hzEEG zKk6A 0-3-0 H i 2-6-0 i 1-0-8 0101 Scale=1:31.6 1.5x4 I 3x6 = 4x8 = 1.5x4 II 3x4 = 1.5x4 II 1.5x4 II 4x6 = 3x4 II 5x6 II A B Q C D E F G H I P 0 N M L K J 3x10 = 4x6= 3x4 = 4x5= 5x8= 1.5x4 II 19-2.0 16-2-0 Plate Offsets(X,Y)- IA:Edge,0-0-121,11:0-3-0,Edgel.IL:0-1-8,Edee1 fM:0-1-6 EdQel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In floc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 1.00 Vert(LL) -0.34 M-N >633 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.86 Vert(CT) -0.48 M-N >445 360 BCLL 0.0 Rep Stress Incr NO WB 0.44 Horz(CT) 0.02 1 n/a n/a BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:80 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD 2x4 OF 1800F 1.6E or 2x4 DF No 1&Btr(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing WEBS 2x4 HF No.2(flat) REACTIONS. (lb/size) 1=1009/0-2-14,0=1073/0-3-2 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-2942/0,C-D=-2942/0,D-E=-3184/0,E-F=-3184/0,F-G=-3184/0,G-H=-895/0,H-1=-896/0 BOT CHORD N-0=0/1887,M-N=0/3355,L-M=0/3184,K-L=0/2241 WEBS I-K=0/1297,B-0=-2110/0,B-N=0/1198,C-N=-269/0,D-N=-469/0,D-M=437/220,G-K=-1528/0,G-L=0/1122, F-L=357/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)I. 4)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6)CAUTION,Do not erect truss backwards. 7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)167 lb down at 3-7-6 on top chord. The design/selection of such connection device(s)is the responsibility of others. 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard ERR LL 6 1)Dead+Floor Live(balanced):Lumber Increase=1 00,Plate Increase=1.00 ,`� WAS Uniform Loads(plo O Vert:J-O=-10,A-I=-100 Concentrated Loads(lb) ti� CEO Vert:Q=-124(F) 51398 9 A� O� BCtSTE,R� �SS7�NALG May 2,2017 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. �� Design valid for use only wah MITeMD connector.This design is based only upon parameters shown,and is for an indwidual bulking component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall buitaing design RrnrJng InAlralnd Is In prwvnnt burkling nl Innlvireml mica wnh nrvlMr chnrA rn•mfinrc only, ArldnAnN lempnmry and permanent Mating MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage.For general guidance regarding the fabrication,storage,delivery.erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-69 and BCSI Building Component 7777 Greenback Lane Sarety Information available from Truss Plate Instdute,21B N_Lee Street.Sude 312,Alexandria,VA 22314. Suite 109 Citrus H ht CA 95610 .� � I I Job Truss FFLOOR ,�pe Oty Ply IF; _S 1623-FL dccR50439575 1623-FL B3 4 1 Job Reference(optional) BMC. EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries.Inc. Mon May 01 22:35:15 2017 Page 1 ID:IgublkbV R27z3USE92FUkDzKpFM-7Y7FIXWLuOnrriASoOELRIOR1OzEavVShzEEG_zKk6A 2-" P L o�1a�D-fa Scale=1:33.2 4x8 = 4x8 = 3x4 = 3x4= 3x6 FP= 5x6= A B C D E F G H I J K W T 3x10 = R O P 0 N M 4 3x6 FP=4x12 = 3x4 = 4x8= 5x8 = 3.4 I 11-4 2028 1e-71-14 1-2-10 Plate Offsets(X.Y)- [A:Edge,0.0-121 [F:0-1-8 Edael (K-D-1 8 Edoe] [K:0-1-8 0-0-121 IPIO-1-8 Edgel (T 0-1-8 0-0 121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.47 Vert(LL) -0.31 P-Q >769 480 MT20 185/148 TCDL 1010 Lumber DOL 1.00 BC 0.69 Vert(CT) -0.59 P-Q >405 360 BCLL 0.0 Rep Stress Incr YES WB 0.44 Horz(CT) 0.11 L n/a n1a BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:92 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat)"Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, A-H:2x4 DF 1 GOOF 1.6E or 2x4 DF No.1&Btr(flat) except end verticals. BOT CHORD 2x4 HF No 2(flat)*Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: L-R:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) 6-0-0 oc bracing:L-M WEBS 2x4 HF No.2(flat)`Except" K-M:4x4 DF No.2&BTR G(flat) REACTIONS. (lb/size) L=1654/0-5-6,S=1128/0-2-10 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD K-L=-1669/0,B-C=-3200I0,C-D=-320010,D-E=-4208/0,E-F=-4208/0,F-G=3738/0, G-1=3738/0,I-J=1238/0,J-K=-1238/0 BOT CHORD Q-S=0/1871,P-Q=013966,0-P=0/4208,N-0=0/4208,M-N=0/2732 WEBS J-M=-797/0.B-S=-2123/0.B-0=0/1509,D-O=-869/0,D-P=-171/551,I-M=-1721/0, I-N=011168.G-N=-291/0,F-N=-803/0,K-M=0/2110 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)A plate rating reduction of 20%has been applied for the green lumber members. 5)Provide mechanical connection(by others)of truss to bearing plate at joints)S. 6)Load case(s)2 has/have been modified.Building designer must review loads to verify that they are correct for the intended use of this truss. 7)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. c� �� 8 Strongbacks to be attached to walls at their outer ends or restrained by other means. v f WASFj 8)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard yP CT0.. 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Vert:L-S=-10,A-K=-100 Concentrated Loads(lb) Vert:J=-580 ��+5'�RF 51398 ISTB� ��2)Dead:Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) S`rr�NAL��G Vert:L-S=-10,A-K=-100 May 2,2017 ®WARNING-Verify design Paramefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTeM connectors.This design is based only upon parameters shown,and is for an individual binding component,not a truss system.Before use,the building designer must verify the appbcablbty of design parameters and property incorporate this design into the overall T building design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only.Additional lemporary and permanent bracing A[le t� is always requiredIt/r R for stability and to prevent collapse with possible personal Injury and property damage.For general guidance regarding the fabrication,storage,delivery,arecuon and bracing of trusses and buss systems,see ANSIrrPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Insldute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite tog Citrus Heku 1�,CA 95610 t Job Truss toss,ype Oty IPty LGI Ht.__S 1623-FL dcc R50439575 1623-FL B3 FLOOR 4 1 Job Reference(optional) BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MITek Industrles,Inc. Man May 01 22:35:15 2017 Page 2 ID:Igublkb W R27z3USE92FUkOzKpFM-7Y7FIX WLuGnrTIASoOELRIOR 1 OzEavV5hzEEG_zKk6A LOAD CASE(S) Standard Concentrated Loads(Ib) Vert:J=330 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev,f0/03/2015 BEFORE USE. Y Design valid for use only with MTeke connectors.This design is based only upon parameters shown,and is for an Individual building component,not a truss system.Before use,the building designer must verily the applicability of design parameters and property incorporate this design Into the overall �{ budding design. Bracing indicated is to prevent buckling of individual truss web andlorchord members only.Adddlbnal temporary and permanent broung MI Ili k' Is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication.storage-delivery,erection and bfacing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. sulls 109 ittufJi_g-Igh� 1 Job Truss Truss i ype Qty Ply LGI Ht,.—S 1623-FL dcc 1623-FL B4 FLOOR 5 1 Jab Reference(optional) R50439576 BMC, EVE RETT,WA 982053212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:16 2017 Page 1 ID:Igublkb WR27z3U8E92FUkDzKpFM-bkhd VMzfZvi5sleM6lazVZaegHIJL3Ewd_ooQzKk69 2.6.0 1 2 i 1-7-14 i 1-3-0 D-k8 Scale=1:34.2 1.5x4 II 1.5x4 = 1.5x4 I I 4x12 = 1.5x4 11 3x6= 1.5x4 11 1.5x4 11 3x6 = 3x6 FP=2x4 I I 6xl2= 1.5x4 = A B C D E F G H I J K T O S 4x8 = Q P O N M 3x6 FP=4x12 = 3x4= 3x4= 6x8= 5x8= 16-11-14 20.2.8 16-11-14 3 10 Plate Offsets(X,Y)— WEdge,0.0.121,IL:Edae.0-1-81.IN:0.1-8.Edael.10:0.1-S.Edae1.IR:Edae.0-1-81,fSAW-8.0-0-121.fT:0-1-8.0.0-121 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.60 Vert(LL) -0.37 O-P >647 480 MT20 185/148 TCDL 10-0 Lumber DOL 1.00 BC 0.80 Vert(CT) -0.68 M-N >353 240 BCLL 0.0 Rep Stress Incr YES WB 049 Horz(CT) 0.14 L n/a n/a BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:91 lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat)*Except* TOP CHORD Structural wood sheathing directly applied or 5-8-5 oc purlins, A-H:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) except end verticals. BOT CHORD 2x4 HF No 2(flat)"Except` BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. L-Q:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) WEBS 2x4 HF No.2(flat)"Except" J-M:4x4 DF No.2&BTR G(flat) REACTIONS. (lb/size) R=1230/0-2-10,L=1836/0-5-6 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-3580/0,C-D=-3580/0,D-E=-4996/0,E-F=-4996/0,F-G=4996/0,G-1=-3711/0, I-J=-3711/0 BOT CHORD P-R=0/2059,O-P=0/4534,N-0=0/4996,M-N=0/4617,L-M=0/1690 WEBS B-R=-2337/0,B-P=0/1725,D-P=-1083/0,D-0=-38/735,G-M=-1169/0,G-N=0/807, F-N=-257/0,J-L=2447/0,J-M=0/2589,I-M=-1084/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)A plate rating reduction of 20%has been applied for the green lumber members. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)R. 5)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard ,`Q R A 46P 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 C �� Uniform Loads(plf) S1' Vert:A-K=-100,L-R=-10 P O Concentrated Loads(lb) Vert:1=-870 rO 151398 qr� tSTe SSI�NAL May 2,2017 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. �� Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an Individual budding component,not a truss system.Before use,the building designer must verity the applicability of design parameters and property Incorporate this design into the overall building design.Bracing Indicated Is t0 prevent buckling of Individual truss web andlor chord members Only,Additional temporary and pamtanom bracing MiTek is always required%of stability and to prevent collapse with possible personal Injury and property damage.Far gonefal guidance regarding the fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSI/TPIt Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Institute,218 W Lee Street,Sude 312,Alexandna.VA 22314, Sidte 100 itru M M A 9 610 .: I I Job Truss Pe i ype Qty Ply LGI Hl...._S 1623-FL dccR50439577 1623-FL B5 1 1 Job Reference o Ronal BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:17 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-3xF7jDYbPtl ZjOKgwpGpV1(6tXEoG2vaN8HjLLtzKk68 0*8 Scale=1:32.4 3x6 FP= A B C D E F G H I J K L M N O P Q cfAJ At 7777L]AAA AH AG AF AE AD AC AB AA Z Y X W V U T S R 3x6 FP= 1-2-12 3-10-12 5-2-12 6 8 12 7-10-t2 ' 9^ 10 8 t2 1 11-10 123_2-12 14-0-12 15 SO 12 17 2 12 18 812 20 2 s r 1-2-12 1 4 0 1 4-0 14-0 14 0 1 4-0 1 4-0 1 4 0 t�i-0 1 4-0 1 4 0 1-0-0 1 4 0 1 4.0 1-7-12 Plate Offsets(X.Y)— [A:Edpe•0.0-121,IAI:0-1-8.0-0-121,[AJ:0.1-8 0.0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ltd PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.02 Horz(CT) 0.00 R n/a n/a BCDL 5.0 Code IRC2015ITP12014 Matrix-R Weight:77 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat)"Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, A-N:2x4 DF 180OF 1 6E or 2x4 DF No.1&Btr(flat) except end verticals, BOT CHORD 2x4 HF No.2(flat)"Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. R-AD:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) WEBS 2x4 HF No.2(flat) OTHERS 2x4 HF No.2(flat) REACTIONS. All bearings 20-1-0. (lb)- Max Grav All reactions 250 Ib or less at joint(s)AH,R,AG,AF,AE,AC,AB,AA,Z,Y,X,W.V,U,T,S FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 5)Gable studs spaced at 1-4-0 oc. 6)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. ��L 8 y� of WAS `Lf A • 0 51398� ,e+ CISTE1t �SSI�NAL B�G� May 2,2017 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall 1 building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Mire fc is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPl1 quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria.VA 22314. Suite 109 Citrus Is.CA 95610 ��� I Jab Truss Truss.ype City Ply LGI Hi _S 1623-FL dcc R50439578 1623-FL C1 fleet 1 1 Job Reference al BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:17 2017 Page 1 ID:Igublkb WR27z3UBE92FUkDzKpFM-3xF?jDYbPtl ZjOKgwpGpWj6tFEod2vGN8HjLLtzKk68 343(� 3x6 11 A 24— 1-3-0 B- Sx�l 0-7-6 , 1-1-B Scale=1,10.3 o.- m 3x4 = 1-5x4 II H G F E 3x4 = 1.5x4 II 3-5.14 3 9 6 3.5-14 0 g Plate Offsets(X.Y)-- (E:Edge 0-0-121,(F:0-1-8,Edge1 (GO.1-8 Edae] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.10 Vert(LL) -0.00 G >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.06 Vert(CT) -0.00 G >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.04 Horz(CT) 0.00 D nla nla BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:20 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 3-9-6 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) H=185/0-3-8,D=185/0-3-6 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 5)CAUTION,Do not erect truss backwards. �R1tIl.0 8 J� of wAsx, 0 R�51398� '�FssIONAL � May 2,2017 ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall budding design,Bracing indkaled Is to prevent budding of individual truss web and/or chord members only,Additional temporary and permanent bracing M iTe k Is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSIITPIt Quality Criteria,OSS-89 and SCSI Building Component 7777 Greenback Lane safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314 Suite 109 Citrus ih6 � . I I Job Truss Trusa ype Qty Pry LGI Hu.—S 1623-FL dcc R50439579 1623 FL C2 Floor Supported Gable 1 1 Job Reference(opillonall BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries.Inc. Mon May 01 22:35:18 2017 Pape 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-Y7oNwZZEAB9QKAv1 UXn23we36e8gnM8XNxTutJzKk67 A 1.5x4 II B 1.5x4 II Scale=1:10 4 W � D C 1.5x4 II 1.5x4 II t 0•tt-12 0-11-12 Plate Offsets(X.Y)— fA:Edce 0-0-121 LOADING (pstj SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.03 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0,00 Horz(CT) 0.00 C n/a n/a BCDL 5.0 Code IRC2015,71312014 Matrix-R Weight:5 lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 0-11-12 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) D=47/0-11-12,C=47/0-11-12 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ALL s ,� of WAskj�c�F�� A� 51398 �SSrONAL��Gl May 2,2017 A WARNING-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system,Before use,the budding designer must verity the applicability of design parameters and properly incorporate this design Into the overall 1� building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord Members only,Additional temporary and permanent bracing Mire 0. Is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSIITP11 quality Criteria,DSB-89 and SCSI Building Component TTT7 Greenback Lane Safety Information available,from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Smle 109 HeightsCitrus CA 95610 �: � - I I Job Truss Truss,ype Qty IPly LGI Hk-.._S 1623-FL dcc 1623-FL F1 Flour Supported Gable 1 1 R50439580 Jab Reference Optionan BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries.Inc. Mon May 01 22:35:18 2017 Page 1 ID:IgublkbWR27z3U8E92FUkDzKpFM-Y7oNwZZEAB9QKAv1 UXn23we33e8enMtXNxTutJzKk67 A B C D Scale=1:10.2 n �u u n H G F E 4-2-4 4-2�4 i LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.03 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.02 Horz(CT) 0.00 E n/a n/a BCDL 5.0 Code IRC2015/TP12014 Matnx-R Weight:15 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-4 oc purlins, BOT CHORD 2x4 HF No.2 except end verticals. WEBS 2x6 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 REACTIONS. All bearings 4-2-4. (lb)- Max Grav All reactions 250 lb or less at joint(s)H,E,G,F FORCES. (lb)-Max.Camp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 5)Gable studs spaced at 1-4-0 oc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �RRIZ,L 8.q 04 WAS,y,, 51398 sy� 0.1 �SS70NAL FAG` May 2,2017 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing Mire�' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 quality Criteria,DSB-99 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandda.VA 22314. Suite 109 Citrus Hei hts CA 95610 Jab Truss Truss ype Oty PlT2job �._S 1623-FL doe R50439581 1623 FL F2 FLOOR GIRDER 1 eference(optional) BMC, EVERETT,WA 98208-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:19 2017 Page 1 ID:IgublkbWR27z3UBE92FUkDzKpFM-OJMI8vasxUHHyKUD1 EIHb8B4E1 HCWkAgcbCSPIzKk66 r 1-9.6 Scale=1:14.8 4x6 = 1.5x4 II 4x6 = 4x5 II A 4x5 I I B 1 C D K E b •J N G 48 = 5x6 = 5x6 = 3-10-3 + 3-10.?7-8-6 -11.14 0.3 8 Plate Offsets(X.Y)— fE:Edge,O 3$) 3-10.3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In floc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.58 Vert(LL) -0 06 G >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.88 Vert(CT) -0.10 G >905 360 BCLL 0.0 Rep Stress Incr NO WB 0.33 Horz(CT) 0.03 F n/a File BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:60 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 HF N0.2 TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins, BOT CHORD 2x4 HF No.2 except end verticals. WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. (lb/size) H=3314/0-3-6,F=3013/0-5-8 FORCES. (lb)-Max.Comp./Max.Ten.-All farces 250(lb)or less except when shown. TOP CHORD A-H=-1176/0,E-F=-724/0,A-B=-319/0,B-C=-6175/0,C-D=-6175/0,D-E=-464/0 BOT CHORD G-H=0/4455,F-G=0/4904 WEBS B-H=-4610/0,B-G=0/1917,C-G=-160010,D-G=0/1417,D-F=-4949/0 NOTES- 1)2-ply truss to be connected togetherwith 10d(0.131"x3")nails as follows: Top chards connected as follows:2x4-1 row at 0-7-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) LL eq Vert:F-H=-10,A-E=-390 Concentrated Loads(lb) Vert:A=-736 I=-694 J=-909 K=-909 51398 �4 �.t> FGis fSR �`rSrO.NAL��G May 2,2017 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 114II-7473 rev.10/03/2015 BEFORE USE. ' Design valid for use only with MiTek®connectors,This design is based only upon parameters shown,and is for an individual budding component,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly Incorporate this design into the overall budding design.Bracing indicated Is to prevent buckling of Individual truss web andlor chord members only.Additional temporary and permanent bracing MITe k is always required for stability and to pravem collapse with possibe personal Injury and property damage For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312.Alexandria,VA 22314. Suite 109 Citrus Heights. 956 10 Job Truss Truss type City ply LGI Hu.- 1623-FL dcc R50439582 1623-FL F3 Floor Girder 1 2 Job Reference twnal BMC, EVERETT.WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:19 2017 Page 1 ID:Igubl kb WR27z3U8E92FUkDzKpFM-OJMIBvasxUHHyKUD1 EIHb8BOt1 GU WIAgcbCSPIzKk66 �i 1-4-11 i7__M244 i 4-1-10 i 2-3-0 2-3-0 Scale=1:34.3 1.5x4 II 3x6 = 1.5x4 II 3x6 = 1.5x4 II 1.5x4 II 3x4= 3x6 = 1.5x4 I 4x8= 3x4 I A B C D E F G H I J S K Q P O N M 3x4 = 4x8 = 3x6= 3x6= 3x4= 6x8 = 3x6 = 3.2-10i 7-10.8 12-7-0 17 2 12 I 20-5•G 3 2-10 4-7-12 4.8.10 4.7-12 3 2 t0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.86 Vert(LL) -0.34 N >709 480 MT20 1851148 TCDL 10.0 Lumber DOL 1.00 BC 0.93 Vert(CT) -0.53 M-N >455 360 BCLL 0.0 Rep Stress Incr NO WB 0.40 Horz(CT) 0.07 L n/a n/a BCDL 5.0 Cade IRC2015/TP12014 Matrix-R Weight:152 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc purlins, BOT CHORD 2x4 HF No.2*Except* except end verticals. L-P:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 REACTIONS. (lb/size) L=3096/0-5-8,R=1387/0-5-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD K-L=-348/0,B-C=-3051/0,C-D=-3051/0,D-E=6704/0,E-F=-6704/0,F-G=6704/0,G-1=-6208/0,I-J=-6208/0 BOT CHORD Q-R=0/1610,O-Q=0/4847,N-0=0/6704,M-N=0/6918,L-M=0/3624 WEBS I-M=-1593/0,C-Q=-304/0,B-R=-1913/0,B-Q=0/1833,J-M=0/3286,J-L=-4374/0,D-Q=2012/0,D-0=0/2081, E-0=-702/0,G-M=-1110/0,G-N=239/751,F-N=-288/0 NOTES- 1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chards connected as follows:2x4-1 row at 0-7-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)Unbalanced floor live loads have been considered for this design. 4)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 5)The Fabrication Tolerance at joint P=12%,joint H=12% 6)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. _ �RRILL LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 �O Uniform Loads(plf) Q Vert:L-R=-10,A-K=-100 Concentrated Loads(lb) Vert:1=-1592 S=-674 51398� w"k otb CISTBR �SSF�NAL May 2,2017 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not s truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall _ bulking design.Bracing Indicated Is to prevent buckling of Individual true web andror chord members ony, Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSVTPIt Quality Criteria,DSB49 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute.218 N.Lee Street,Suite 312.Alexandria,VA 22314. Sure 109 t sH' A9 10 I I Job Truss Truss Ty, Qty Ply LCI HOMES dcc 1623-FL xi FLOOR 1 1 tnh Reference(gglionall R50439583 BMC,EVERETT,WA 98205-3212 8.010 s Jul 7 2016 MiTek Indushles,Inc Tue May 07 07*45,08 2017 Pago 1 ID:Igublkb W R27z3U8E92FUkDzKpFM-_?tqF WugMgABaT55gRPXZhB9vTxHM2b92i?aTfzKal9 1-5.6 A 3x4= F B 1.5x4 11 Scale=1:9.1 ZI T. E C 1.5x4 I 3x4= 1-1-10 1-8.6 1-1-16 0.6-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.33 Vert(LL) 0.00 D "" 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.00 Vert(CT) -0.00 E >999 360 BCLL 00 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 C n/a n/a BCDL 5-0 Code IRC2015frPI2014 Matrix-R Weight:8 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 1-8-6 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) E=109/1-1-10 (min.0-1-8),C=1 71/Mechanical,D=11/0-1-8 (min.0-1-8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors 3)Refer to girder(s)for truss to truss connections 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)D. 5)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1 00 Uniform Loads(plf) Vert:C-E=-10,A-B=-100 Concentrated Loads(lb) Vert:F=-117 WAsj� 51398q/� O,t+ �CISTER�� NAL��G May 2,2017 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MI TEK REFERENCE PAGE 11,1II.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTok®connectors,This design is based only upon parameters shown,and Is for an IndNWuai building component,not a truss system Before use.file budding designer must verify the applicability or design parameters and property incorporate this design into the overall 7 building design.Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing -- --- '7e IC 1. Is always required for stability and to prevent collapse with possible personal injury and property damage, For general guidance regarding the 1 fabrication,storage.delivery.erection and bracing of trusses and truss systems,see ANSUTF41 Quality Criteria,06849 and SCSI Building Component 7777 Greenback Lane safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Maxandna.VA 22314. crude 109 ciltmisM ig_hta A 95510 c)N z _ (n co (n y D �, rD c tl CD m � � o U mc.MW .Z W K m I I jV C [lam nca 0(p 7 �N ai n 7 � O 7 CL9- y70 9cnWic _a �'_ � a Z soggy ('D °1 om � nvT mDpon Z �Wo3a.(Wi °1 N6 � �' ac (D0 fD yam cy �c,m U3 a� 3 � D O 0. O W n 7 NCD 7 (D W �-' (D O 7 N S N d o K O N x C`G 7 N Z Q. Q O N �_W ❑ A7 0 O N O(D (O�1 O O Q(D CD 6 D a CD 0 w a .�W O Q a C O N W 7 fD W O N O N Cn W O n ? (D goo Gl, O'.� � W O c (D lD o �' N � (D N W Q�; (D �.61 0 67 i O' ° v 3 O m QaN 7 y 0'O: O 7 QO -OQ.0 Rl y � om0 �m mm � > — �.a z 7 � 0L a Z m =_� m o' o�.a� f a 7 0 am 3 o ai o m o Q`o_; > W 7 ' (n 7 7 C) O � N (O y 0 3 C 7 (D S. Q 7. D d 7 0� o 0p C7 N W y (�D (� N � y j C N � y N N 3 N rt O N S S CD �0,6.W o.� (n 0 Q(D c in CD N L, O O 7 N S O y S 7 (D y W 7 N umi n c= =z O TOP CHORD o � N C m W r C-1 OD ct-a (c N m ow 'n mo mz(a n a M ca>C N M- (oD -I S m M C ,a< 3co o a X cn O (D CD T ❑N O --I g -q m O co O N < (gyp N w m m C Z coV rnw D mm co yz O 0 7 N cn n u' y v(Di a M N V (n r O Q N aCD �. s -. Q N O �O �M O p �C cn CD O O < m \cu�n (D O N w CO Z = 0 N. r° N (0•N 7 Q v co r -Z( O m-1;0 p� CD fD O N 0 -i cl) O cf) J m o N p X _F N N 03{ Lm -0 CD D j n eo m c- S 7 < O N ` �m VC4-S4.h- cnW m 7 O a"� O m o N�+ W N ((D S Z M n vN No X G Z (D 2 0(D W m ncn C S2 (1)X tit CL (D O m TOP CHORD N O !O W �I (O W :-1 W Ut -0. W N DO Z' ;a � ?C 5 m0 o o -o- Nor 5v cp0 �� o`o'v Or day ,nz c3 §j aD �� 7a� o.<,� ". a° dv° mm � ad 3Nm �o m7 mN ohm =�° o mm dmdc �a 3 C 9 m m > > o (D n� v3 � -m y D, o o .< o < o< (oa a ao = °3 9 m (K�- 5.S: 7 y �� om o 3 0� Q xm w o fl7 m c m m 3 3 °-'2 2 a ° `o° a N av -" m °o �'m v� m m m 3 m � 2 Q m 0 (O (D a o O 7 >• G N m N O O;4i X (p O N N .m. Q O m C(y/1 m m CD 0 .�,(D 7 O a N 'O X 7 N W m (D o(D N V1 O m° m ° Q 1CL m� aim m� om 3c �3w m N o.m O c 3 0 7m 7 oy �3 �+ R' m 7 m m m3 ao H ism ID cv-.0 Xm TI 0 -o m 3 a m= ° mm m I 3m m oo �y (o N �0 3ao y2w a, �+ Sr a m 4 < o mm a a 7 m Z _a o m o 0 0 0 c_� 3 < � �� m and �, o c o� y - 3� 62k m7 W7 7^ ��°' m �7 7 0 o7 c� � < CD 7 c Q• s m cD m 7 a m c» a N c ^°, v o m y °:��' m -0 c 3 m o`-o .a o' 3 $ m� 'moa mN �� �� o0 3 ad(3 a c a _� ^ may 70a(D � m Vl mN c9c m y » r �0 2 m� a <a y� O d � Aa m 3 'm m ww is � °:0 m m 3Er •3 a� .<o rn2.y m°' aN mro 7 n 9 m 3 m 'C mm om SDo mH m ° :E Dm° oa ° D°1 mm �� o v O o N O' ((DD a Q a CD �7 O O j 2 a p'.y.. �O' Z m m - N N a 0.3 m C 7 > N o (� (D a 7 N v N C N (n 7 c 10 N �Z j 0'1 N 'G ... (n j N O N A 7 n. -O G)a ZZ Ol O Z C f u! 7• O'f0 ry (D V N tlCi ^� O o n N(G N N �• J N + (n Ct .m+ (p D� 3 N l J Cn O. ax_� O 01 3 VI .mi = 7 7 N.mi., N 7 Q '-(D (p W �G° O� 6 j C.'< :i N a ? m a N 7 07CL 3 m7o O(D �`< u..!A O N a �y(� aN (D x 7 0... .y (D O N W 3 y 7 n m P O .. p O S O c y }h Q 3 CD �� C)m 7 `G G Q (D a O-0 3 CD N a (n /� m p Q 7(D O O N a 7 �a C N N a ID 7 5 m Co fD T (D ° 7 C 2 (D a (D m N tl y 'o(f 3 - j J N (D ,N (D W y1 mm (D 7. 0.1 a 7 (D CL a 0 M 0 Tl CI O CD a' c o 3 m (D s 3 N z m 0 i i I 4.00-00 I c b - o S to a -- O O W O N b 0 t A 7 O c b rn o � o N rt d K — O c ffi-2 rt y �Yy►� y 51 y II OOyn rrA ='A 1 o n r �r y rrA -rAO �p Received -OOr r o OCT 31 2017 ?JP III pn CuryrslDniryM Nl BuIAH LGI HOMES Job Number Sllpl MM oBMC 13200 35b A—NE E-K WA 1 NMI lob Name/Model 1623-A RF GR p�si0n�f ppN C. TRUSS LAYOUT I Olho[12678&3tOB Address: '}tq-yps�C411Y(nrgMG.conlmmc@NMA1etSL�caro peso s/uzov P, MiTek" MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Re: 1623-A RF Fax 916/676-1909 LGI HOMES 1623-A RF dcc The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by BMC West-Everett,WA. Pages or sheets covered by this seal: R50439584 thru R50439593 My license renewal date for the state of Washington is May 16,2019. ospimt 6 J� OF WAS/gj �{A .P is SI May 2,2017 Baxter,David IMPORTANT NOTE:Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. Job Truss True. ype Oty Ply LGI K zS 1623-A RF dcc R50439584 1623-A RF Al Common Supported Gable 2 1 Job eferenco o Bonet BMC, EVERETT,WA 982C 3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:19 2017 Page 1 ID:c6YFzpC3Udxr696bt?jEAAzKIH W-7C6psOFXw71bRIKRB N3c4eBB91 Tj WpwgcbCSPIzKk66 t-0.0 8-9-0 it -0 r 12$-0 �-0 5.9-0 5-g•0 1.OA Scale=1:21.6 4x5 = D 5.00 12 2x4 II 2x4 II C E N M L 0 P K B F J I H 3x4 = 2x4 II 2x4 II 2x4 I 3x4 = 11•b-t1 LOADING (psf) SPACING- 2-0-0 CSI, DEFL. In (loc) I/deft L/d PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.14 Vert(LL) -0.00 G n/r 180 MT20 185/148 (Roof Snow=25.TCDL 7. Lumber DOL 1.15 BC 0.08 Vert(CT) 000 G n/r 180 BCLLL 0,0 Rep Stress Incr YES WB 0.03 Horz(CT) 000 F n/a n/a BCDL 10.0 Code IRC2015TTP12014 Matr,x-R Weight:36 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 HF No 2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 REACTIONS. All bearings 11-6-0. (lb)- Max Horz B=-34(LC 13) Max Uplift All uplift 100 lb or less at joint(s)B,F,J,H Max Grav All reactions 250 lb or less at joint(s)B,F,I except J=332(LC 19),H=332(LC 20) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-0-0,Exterior(2)2-0-0 to 2-9-0,Corner(3)2-9-0 to 5-9-0, Exterior(2)8-9-0 to 9-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 2-0-0 oc. "„D r•L e 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide a`9 WASk will fit between the bottom chord and any other members. 11) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B,F.J,H. 51398 y� Eats �s`rtONALENU` May 2,2017 AWARNING-Verffy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verily the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Ife fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314 Suite 109 Citrus Heights,CA 95610 Job Truss Tina, ype Oty Ply LGI K S 1623-A RF dcc R50439585 1623-A_RF A2 KINGPOST 2 1 Job Reference o Ronal BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:19 2017 Page 1 I D:c8YFzpC3Udxr696bt?jEAAzKIH W-7C6psOFXwZzbRIKRB N3c4eB8s1 OV WpdgcbCSPIzKk66 5.9-0 128-0 1A-0 5-9-0 5-9-0 { 1-0-0 Scale=1:21.6 4x5= C 5.00 12 I J K H G L B D i E Id F 3x4 = 2x4 II 3x4 = 11-8-0 I 5.9.0 5.9-0 LOADING (psf)TCLL 25.0 SPACING- 2-0-0 CSI. DEFL. In (loc) Well Ud PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.35 Vert(LL) -0.03 B-F >999 240 MT20 1851148 TCDL 7.0 Lumber DOL 1.15 BC 0.29 Vert(CT) -0.06 B-F >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(CT) 0.01 D n/a n/a BCDL 10.0 Code IRC2015(TPI2014 Matrix-R Weight:33 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No 2 REACTIONS. (lb/size) B=542/0-5-8,D=542/0-5-8 Max Horz B=-34(LC 13) Max Uplift B=-40(LC 12),D=-40(LC 13) FORCES. (lb)-Max.Comp./Max.Ten -All forces 250(lb)or less except when shown. TOP CHORD B-C=-740/104,C-D=-740/104 BOT CHORD B-F=-29/620,D-F=-29/620 WEBS C-F=0/253 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.ll;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 2-9-0,Exterior(2)2-9-0 to 5-9-0, Interior(1)8-9-0 to 9-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category Il;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25 0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)"This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. r� 8 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B,D. 51398 O� FCIST- w �SS�ONALE�U`� May 2,2017 A WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7477 rev.10/02/2015 BEFORE USE. Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSUTPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Hih A 95610 1 Job Truss Trus. .Ipe Oty Ply LGI h_ _S l623-A RF dcc R50439586 1623-kRF A3 Jack-Open 2 1 Jnb Reference o Honel BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:20 2017 Page 1 ID:c8YFzpC3Udxr696bt?jEAAzKIH W-bPgC3MF9ht5S3uvdl4ardrkM WRpdFGdggFy?xBzKk65 .1.0-0 3.6-D 4 1-0-0 3-6-0 Scale=1:11.8 C 5.00 12 E di N� B A D 3x4 = 3--0 I LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/defl L/d PLATES GRIP TCLL 25.0 (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.16 Vert(LL) 0.01 B-D >999 240 MT20 1851148 TCDL 7.0 Lumber DOL 1.15 BC 0.10 Vert(CT) -0.01 B-D >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 C n/a n/a BCDL 10.0 Code IRC2015/TPI2014 Matrix-R Weight:10 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No 2 TOP CHORD Structural wood sheathing directly applied or 3-6-0 oc purlins- BOT CHORD 2x4 HF No 2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) C=88/Mechanical,B=228/0-5-8,D=32/Mechanical Max Harz B=50(LC 12) Max Uplift C=-36(LC 12),B=-25(LC 12) Max Grav C=95(LC 19),B=230(LC 19),D=64(LC 5) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;Irl Cat.11;Exp B;enclosed; MWFRS(envelope)gable end zone and C-C Exterior(2)zone;Cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Refer to girder(s)for truss to truss connections, 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)C,B. `�t,�R1tILI,e J OF WASJy,, •, O 51398 o,�A �orsreR�° , SSrONALE�G May 2,2017 AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®conneclors.This design is based only upon parameters shown,and is for an individual building component,not a truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing We • is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,21 B N,Lee Street,Sugn 312,Alexandria,VA 22314. Suite 109 Helahts.CA 95610 Job iTruss Tfua. 7pe Qty Ply LGI F. cS 1623-A RF dcc 1 R50439587 1623-ALRF B1 Common Supported Gable 1 1 Job Reference(optional) BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:21 2017 Page i I D:c8YFzpC 3Udxr696bt?jEAAzKIH W-3bEaHiGnSBDJg2 UgJo6493GXJr9x_jNz3viZUezKk64 t &1-0 8-1-0 1-0-0 Scale=1:29.1 4x5 = E 5.00 12 D F P O C G m O R B H I$ 3x4= N M L K J 3x4= 16-2-0 _ 16-2-0 LOADING (psf)TCLL 25.0 SPACING- 2-0-0 CST. DEFL. in (loc) I/deft L/d PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.16 Vert(LL) -0.00 1 n/r 180 MT20 185/148 TCDL 7,0 Lumber DOL 1.15 BC 0.10 Vert(CT) 0.00 1 n/r 180 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 H n/a n/a BCDL 10.0 Code IRC2015rrP12014 Matrix-R Weight:55 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 REACTIONS. All bearings 16-2-0. (lb)- Max Horz B=-45(LC 13) Max Uplift All uplift 10O Ib or less atjoint(s)B,H,M,N,K,J Max Grav All reactions 250 lb or less at joint(s)B,H,L,M,K except N=338(LC 19),J=338(LC 20) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-0-0,Exterior(2)2-0-0 to 5-1-0,Corner(3)5-1-0 to 8-1-0, Exterior(2)11-1-0 to 14-2-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSIrrPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. R1uL 9)Gable studs spaced at 2-0-0 oc. L 8 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. WAS 11) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide t�OF k��C e will fit between the bottom chord and any other members. T� p 12) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B,H.M,N,K,J. 51398 4t� QISTBR �SI�NAL - May 2,2017 AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTekS connectors This design is based only upon parameters shown,and is for an individual building component,not a Truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing P11 0 is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-59 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Hei hte CA 95610 �: I 1 30b Truss Trub, ,pe Oty Ply LGI h. 'S 1623-A RF dcc R50439588 1623-A RF C1 KINGPOST 1 1 Job RoWerim 8onal BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:22 2017 Page 1 ID:c8YFzpC3Udxr696bt?jEAAzKIH W-XnoyU2 HPDU LAI C30tVdJiGpYPFNcj9361ZR604zKk63 e11 0.0 8-1-0 13.3.0 8 28. -0 .27-BA 100 81-0 { 5-2-0 133.0 1-0-01 Scale=1:45.8 TRUSS DESIGNED FOR WIND LOADS IN THE PLANE 4x5 -_ OF THE TRUSS ONLY.FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE),SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE,OR CONSULT H QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. F J 5.00 12 6x12 = Z AA D L C AB E M N 0 y AC B P Q I$ w 3x6= X 3x6 C 3x4= 3x4 26.6-0 B-1-0 18-5-0 Plate Offsets(X.Y�-- IC:0-6-6,Edgel LOADING (psf) SPACING- TCLL 25.0 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.78 Vert(LL) -0.11 B-X >999 240 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.58 Vert(CT) -0.23 B-X >848 180 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.03 P n/a n/a BCDL 10.0 Code IRC2015/TPI2014 Matrix-R Weight:111 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2"Except" TOP CHORD Structural wood sheathing directly applied or 4-0-14 oc purlins. C-V:2x6 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. BOT CHORD 2x4 HF No.2 JOINTS 1 Brace at Jt(s):I,G WEBS 2x4 HF No.2 REACTIONS. All bearings 10-9-8 except Qt=length)B=0-5-8 (lb)- Max Horz B=-71(LC 13) Max Uplift All uplift 100 lb or less atjoint(s)B,T,S.R,P except U=-277(LC 19) Max Grav All reactions 250 lb or less at joint(s)T,S,P except B=813(LC 19),V=993(LC 1),R=260(LC 1) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-1262/71,C-E=-947/100,E-G=-996/113,G-1=-1056/128,I-K=-1060/128, K-V=-1088/136 BOT CHORD B-X=-64/1078,V-X=-67/1072 WEBS C-X=0/353 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 10-3-0,Exterior(2)10-3-0 to 13-3-0, Interior(1)16-3-0 to 24-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. _�``���RRILL 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is r� e the responsibility of the fabricator to increase plate sizes to account for these factors. �� O�W]ggp, 6)All plates are 2x4 MT20 unless otherwise indicated. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads 8)•This truss has been designed for a live load of 20 Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. - 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B,T,S.R,P except(jt=lb)U=277. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. �SStONAL$�G May 2,2017 AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an Individual building component,not a truss system Before use,the building designer must verify the applicability of design parameters and properly Incorporate[his design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the INTO fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N Lee Street,Suit-:312.Alexandra,VA 22314. Suite 109 Citrushts CA 95610 ,: I Job Truss Trub.- rpe Qty, Ply LGI h- =S 1623-A RF dcc R50439589 1623-,-RF 01 HOWE 1 1 Job Rawance toptionob BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:23 2017 Page 1 I D:c8YFzpC3 Udxr696bt?IEAAzKIH W-?_MKi011_oT1 wMeCQD8YFU MnZfhTSToGXDBfY WzKk62 10.5-6 15.0-0 16 9.0 23-0-10 30,0.0 81 O G 1-0-0 10-5-6 4-6-10 1-9-0 6-3-10 6-11-6 1 Scale=1:51.3 TRUSS DESIGNED FOR WIND LOADS IN THE PLANE 4x5= OF THE TRUSS ONLY.FOR STUDS EXPOSED TO WIND I (NORMAL TO THE FACE),SEE STANDARD INDUSTRY 3x10 GABLE END DETAILS AS APPLICABLE,OR CONSULT H J QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. AE 8 Z G 5.00 12 AD AA F 3x6 I UV 3x4 E 3x6 I K rPb W D C X 4x5 11 AC Y 3x6 11 AB 3x6 11 B _ L M j$ P 3x4 = 3x10= Q O N 3x6= R 3x4 = 3x10= 3-1-12 10-5-6 16-9-0 23-0.10 30-0-0 10-5-8 6-3-10 6.3-10 6.11.6 Plate Offsets IX.Y)— IR:0-3-8 0-1-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 25.0 7 Plate Grip DOL 1.15 TC 0.56 Vert(LL) -0.13 O-Q >999 240 MT20 185/148 TCDL (Roof Snow=25. .0 Lumber DOL 1.15 BC 0.67 Vert(CT) -0.24 O-Q >999 180 Rep Stress Incr YES WB 0.68 Horz(CT) -0.10 B n/a n/a BCLL 0.0 Code IRC2015/71312014 Matrix-R Weight:139 lb FT=10% B DL 10.0 LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-14 cc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. WEBS 2x4 HF No.2*Except* JOINTS 1 Brace at Jt(s):T,U,X.Y J-R:2x6 HF No.2 REACTIONS. (lb/size) B=225/3-11-8,R=1211/3-11-8,L=1208/0-5-8 Max Horz L=80(LC 16) Max Uplift R=-89(LC 12),L=-73(LC 13) Max Grav B=269(LC 19).R=1211(LC 1),L=1208(LC 1) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD I-J=-442/91,J-K=-1591/123,K-L=-2303/101,B-C=-448/0,C-D=-507/0,D-E=-446/0, E-F=-443/11,F-G=-445/30,G-H=-476/56,H-1=461180 BOT CHORD B-R=0/399,Q-R=-29/1938,O-Q=-29/1938,N-0=-113/2041,L-N=-11312041 WEBS R-Y=-1774/134,X-Y=-1786/132,W-X=-1738/120,U-W=-1692/107,U-V=-1251/116, T-V=-1226/106,S-T=-1200/98,J-S=-1270/108.K-N=0/279,K-0=-751/113,J-0=0/698, O-U=-753/100,Q-U=0/276,C-R=-360/107 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0.Interior(1)2-0-0 to 12-0-0,Exterior(2)12-0-0 to 15-0-0, Interior(1)18-0-0 to 28-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. RRll l 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs aA O wAs �f� non-concurrent with other live loads. v 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is CEO�� the responsibility of the fabricator to increase plate sizes to account for these factors. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. - 8)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)R,L. .0� R 51398 Off, �QIST'BR� �SSr�NAL��G May 2,2017 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Me , is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-09 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suito 312,Alexandria,VA 22314. Suite 109 itrus Heights CA 95610 Job Truss True-.ype ON Ply LGI h_ _S 1623-A RF dcc R50439590 1623-A RF D2 Common 14 1 Job Reference Ifonal BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Man May 01 22:35:24 2017 Page 1 ID:c8YFzpC3Udxr696bt?jEAAzKIHW-TAwvjlfl6buXWCP wfnnhuss2z3B2vPltwD4zzKk61 - 15-0-0 22-2-2 3%0-0 81-0A 7 1-0-0 7-9-149-14 7-2-2 7-2-2 7-9-14 1-OA Scale=1:51.3 4x6 = D 5.00 12 M N O 2x4 \\ L 2x4 C E n' K P B F G jd J I Q R H 3x6 = 3x4 = 3x4 = 3x4 = 3x6= 19-9-6 30.0.0 ) t rl-?_S O 9fi 1 10.2-10 LOADING (psf) SPACING- 2-0-0 CSL DEFL. In (loc) I/deft L/d PLATES GRIP TCLL 25.0 (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.91 Vert(LL) -0.36 H-J >980 240 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.90 Vert(CT) -0.59 F-H >596 180 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(CT) 0.10 F n/a n/a BCDL 0 0 Code IRC2015(TPI2014 Matrix-R Weight:103 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 REACTIONS. (lb/size) B=1319/0-5-8,F=1319/0-5-8 Max Harz B=-80(LC 13) Max Uplift B=-74(LC 12),F=-74(LC 13) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown TOP CHORD B-C=-2485/142,C-D=-2180/136,D-E=-2180/136,E-F=-2485/142 BOT CHORD B-J=-127/2205,H-J=-5/1484,F-H=-56/2205 WEBS D-H=-28/805,E-H=-536/174,D-J=-28/805,C-J=-536/174 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 12-0-0,Exterior(2)12-0-0 to 15-0-0, Interior(1)18-0-0 to 28-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1 1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B,F. 4V OF WA$k � 51398 �'� o �cIlsTaR�° sStoNAL���'� May 2,2017 A WARNING-Verffy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing 10, , is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-99 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,219 N Lee Street,Sug-3 312,Alexandria,VA 22314. Suite 109 Citrus Heights CA 95610 .�•� I Jab Truss Trull. /pe 10ty Ply I LGf H. -S 1623-A RF dcc R50439591 1623-A RF D3 Common Supported Gable 1 1 .lob Reference(optional) BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:26 2017 Page 1 I D:c8YFzpC3Udxr696bt?IEAAzKIH W-OY 1 TKPKwHjrbnpMn6LhFs6_PpstifzPiDBP K9rzKk6? .1 OOr 15.0.0 3D-" at 06 1-0-0 r 15-0-0 15-0-0 1-0-0 Scale=1:51.7 4x5 = I H J AH AI 5.00 12 G K AG AJ F L N E M uti D N C O AF AK B P ° j$ 3x4 = AE AD AC AB AA Z Y x W V U T S R 3x4= 3x4 30-0.O LOADING (psf)TOLL 25.0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.11 Vert(LL) 0.00 P n/r 180 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0,06 Vert(CT) 0.00 O n/r 180 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 P n/a n/a BCDL 10.0 Code IRC2015/TPI2014 Matrix-R Weight:126 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing OTHERS 2x4 HF No.2 REACTIONS. All bearings 30-0-0. (lb)- Max Horz B=-80(LC 13) Max Uplift All uplift 100 Ib or less at joint(s)B,Y,AA,AB,AC,AD,AE,W,V,U,T,S,R,P Max Grav All reactions 250 Ib or less at joint(s)B,X,Y,AA,AB,AC,AD,AE,W,V,U,T,S,R,P FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;enclosed; MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-0-0,Exterior(2)2-0-0 to 12-0-0,Corner(3)12-0-0 to 15-0-0, Exterior(2)18-0-0 to 28-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated 6)Gable requires continuous bottom chard bearing. _`�� Lt 9)Gable studs spaced at 2-0-0 oc. r� 8 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ,19 OF Wp 11) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide �C� 10N will fit between the bottom chord and any other members. �Q 12) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B,Y,AA,AB,AC ,AD,AE,W,V,U,T,S.R,P. 13) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)B,P. r0� 51398 o AL May May 2,2017 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MR building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPl1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suito 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 r r Job Truss Trus, rpe pty Ply LGI h S 1623-A RF dcc �1623-A RF AA Jack-Open 5 1 R50439592 Job Referenced t(anal BMC, EVE RETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Inc. Mon May 01 22:35:26 2017 Page 1 ID:c8YFzpC3Udxr696bt?jEAAzKIHW-QY1TKPKwHjrbnpMn6LhFs6 PjstRf 6iDBPK9rzKk6? 1 0-0 1-0-0 t-0-0 1-0-0 Scale=1:6 5 C 5.00 t2 B A D 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/defl L/d PLATES GRIP TCLL 25.0 25.7. Plate Grip DOL 1.15 TC 0.12 Vert(LL) 000 B >999 240 MT20 185/148 (Roof Snow= Lumber DOL 1.15 BC 0.01 Vert(CT) -0.00 B >999 180 TCDL 0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 B n/a n/a BCLL 0.0 Code IRC2015/TPI2014 Matrix-R Weight:4lb FT=10% BCDL 10.0 LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) B=141/0-3-B,D=6/Mechanical Max Horz D=24(LC 8) Max Uplift B=-36(LC 8) Max Grav B=245(LC 18).D=18(LC 5) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;enclosed; MWFRS(envelope)gable end zone and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25 0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Refer to girder(s)for truss to truss connections. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)B. coo .off 51398 �'r �•t��FCIselry NAL ECG May 2,2017 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall "n building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MIT ek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Street,Suit:312,Alexandria,VA 22314. Smile 109 Citrus Heights,CA 1 Job Truss rue ,pe Oty Ply LGI K S 1623-A RF dcc 1623-A—RF J3A Jack-Open 6 1 R50439593 Job Reference Bonal BMC, EVERETT,WA 98205-3212 8.010 s Apr 20 2016 MiTek Industries,Ilm Mon May 01 22:35:27 2017 Page 1 ID:c8YFzpC3Udxr696bt?jEAAzKIH W-ulbrXILY21 zSOzxzf3CUPJ WZIGCIORMsRr9thHzKk6 r •1-0-D 3.O.D 1-0-0 3-0-0 Scale=1:10.8 C 5.00 12 E r' B A D 3x4= l 3-0.0 3-U-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP (Roof Snow=25. TCLL 20) Plate Grip DOL 1.15 TIC0.16 Vert(LL) -0.00 B-D >999 240 MT20 185/148 TCLL 7. Lumber DOL 1.15 BC 0.07 Vert(CT) -0.01 B-D >999 180 EICLL 00 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 C n/a n/a BCDL 10.0 Code IRC2015/TP12014 Matr-x-R Weight:9lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. (lb/size) C=69/Mechanical,B=210/0-5-8,D=27/Mechanical Max Horz B=44(LC 12) Max Uplift C=-29(LC 12),B=-26(LC 8) Max Grav C=73(LC 19),B=218(LC 18),D=54(LC 5) FORCES. (lb)-Max.Comp./Max Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;enclosed; MWFRS(envelope)gable end zone and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live loads. 7)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Refer to girder(s)for truss to truss connections. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)C,B. J� OF WASkj 51398 O FGISTER� SsrONAL 6�G May 2,2017 WARNING-Verify design paramefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111I1.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors,This design Is based only upon parameters shown,and is for an Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall Hebuilding design Bracing indicated is to prevent buckling of individual truss web andlor chord members only.Additional temporary and permanent bracing � is always required for stabdlty and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSUTPII ousllty Criteria,Ds8.89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suiki 312,Alexandria,VA 22314. Sidle 109 Citrus h s CA 95610 v� I Vv cn �, a V• � W DC : II p D� X m m z o0co ? o r m ° O cr= >_ O � � Iol.mo' M v a(p O(G 7 O N N a 7 m W_ � n�7 p �� Z CD m �7 o m DOo C� Z a RD O d 7 (D J' N C Q 7 n O O�.S N O n y 0� - 7 a �(D �wo 3 n(o� �' N.c � �_ n� fD�i r m N no m N'Co m (o A oa CD 7 D o n.�o aM m 7 a (D �' � O 7 in Su ,�^'o<i n Q< o Nox �a y N m p n C7 n (O 3 O 3 N �?� om ommo � ?m m� D o CD ate° f2C/1 �o m (D O (a �� (n000n Frnoc�i �' hoc maces eu m� �• �) m' 6mno N 7 fD O �,Ol c) 7.O'7 C O' N O m d a N O N O d O N Q'Q O n 7 Z m _ 0 CD N °7 =�� w o' o�.o F Q( o Z as o 3 � a o• �5��. S N o 3m7 m : xn D N n co N 7 (D O N S (D a N !D N N 5 S E. C =1 N Q O O O C N o N fD 7 CD 0 O_ (7n 7 S O CD S N O a 7 7 n b, O gag 3 S n�.N C (O 0 3 [n O D-(D O N (D O N y Z ^' CD 7 0 �•`� 07 7 N 7 C = Al 7 O O (D N O 2 E f0 O .7-'6 �. O 7Q y'p� w O „�.j X a O � O 7 .«((O S O N N 5 `G 7 (D ' N N CD m c m m n v z D c TOP CHORD c x x�o m 9 N ai � n o 30 mOz °o c-D 7 m C m ow mo mZvi 7' OD Q 7 fn --4� n y 0 1 0 D _ �. mQ w m u�i m �z m m 0') COD < m v O m c° /�D m C c cn N cn D �'w y r- O Dui-7 U ro 'Z N ai ai D a �m v m p 5 X n �� O o � < p m � m n-qoal N o m nO m m Sr �• wo A < a N w m m o f N — CD ,. N Z Z m X m °' t+ni Cl) d y ocya O o N v Z ;a n N < D CD CD m O Yam' ��o d`" o co N !Zm o V G s t CD N N (r A n Cl) 7 a m TOP CHORD N (O OD �l Of Un A W N O (O DD v O N A W N O ' ZNv m�� � �y S �O Cl oW v� v5� 5� � N(� NC �C 5O o`o'� 0 mn� �Z Q3 In J ac ° <.fD N a° j '°� D)� (D DI O•Gl mD) OJ J NN �.J..� .c+ QN O n < and d2 Ol a �0 o�� m o o m 3o J a o 0 o c �fD vov FN w mo y �o 3 �°c �c�o �� �y o O �m c c m � 310 2 aCO a;° 1 0 RD c nv � w� -D �p vJi o.d 3 0� m x m� m m �m N y (pN a p O S 9n W O Q y -.K ry O y ((7� RI �y C2 N- (O.J_(D J J O O-y N y d' x 7 7 y D]fD fD O' 7 p fD S-•y n O O c •�v O y (O/ N y Q•�'D) W N C 3 y N�CD J. O N y j .y.. O D N r.°-.7 (D O O. J w JO fD y 9 C N y 3(D 2 O .Oi N fD J(D (D 0 7 y y'�'.y U a G v M,O 1 d m m O J',..' < N CD _ N m OD >• a J N O-y y (c' O 0 0 7 O'd .3 \V J 7 fD O-^' N J `< N _ (D (D ° (p fD n. C. Ol ^�' `G 3 O y O-(D fD �O y J L O- c - .O 0 2 a J J c C D) O- O-J J J 10.y.. (]`< (� N O (p N N pppS t0 c j N G1 O- CID N fn N O M d 2 O1 O N =O. O t_O j rr 1 0CC J CD N N D-y (D J O-fA 2 .J,.(D (D .0 (p`G S .� N N_ N .CD 3 J 01 cn G _ cD N y 2 ID. ° O 39 0-0151 O_ a) O- O O.Z N l(p O. 0�O n Q /� iD Ol N C y .. y 0 O a M 5' 'O °y u z (D Z 2 7 G l J 01 a y c l 3 y (D l0°.1 Er v O R .01 fD --3 n -0 C. y W r a y Dl 10 c .T7 d ry (p 3 J (D N J S O' 7 y 3 �. y y C O fD c mC cD (D m° m m (D 5d �i° my � ° Duo oa dy m m� c'o O 5: n m o o- — Zm w = a a3 _J m C J J y O C S. O N N O. z O N 0'1 N M C D fD N a y N N �G J �.�.G N 2 ` /Q'� 0 J M J d Q Oq N J O �. C(O� ,n G 10 Q(O� Z C y J ° J S 41 O O.6 N l J /w) N- �_ p N,O 1 7 y .D.1 J .+J O N 7 ^ O n N C y I .Ji O � N J y » J W O O N fD y J a ID (D y W 0 Ol Q J y m m v S v �n OJ v3 01Jo sl �� u2t91i ° o m aJ —dam am J c� N� G � =r y JO• �� a j -V J' S S 2 Dl CD 3 N CD N J 3 3 K fD < N .3 y J M a j' N ,. N O- y 7 (n- CD /A f 01E °�i CDD c ° 'y n m J (�N_CD m �� c m v� mm m(c \I/ j 0 N O 2. O O N a 7 y (D �° 3 (D J 10 < 3' QJ 1 CD n c v m v s J n o. .S m e o. o. m y-n 0 O y O- N N (D I° y 0 O J CD(D 2 O (n w O G M' o �0 3 y Z p 1"F N 'y 1 I I NASH&ASSOCIATES ARCHI 'T"ECTS PLAN 1623 BEAM, LATERAL & SEISMIC CALCULATIONS 25112 _..::mod. ...•-rz r ti �• -1 i:C�laTERED1 1� 1�oe;-)�',A 5?� M 4 S� oe i STAT" 0P WASHINGTON -.,,,, �Kw Received OCT 312017 2015 IBC c n`A JULY 1, 2016 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH-ARCHITECTS.COM 4 CLIENT: NASH"ASSOQATES BEAM DESIGN DATA PROJECT: ARCIIITECTS DATE:_ NAME: Roof Loads: LL 25#/sf DL 15 #/sf Total 40#/sf [Unless Noted Otherwise Floor Loads: LL 40#/sf DL 10 #/sf Total 50#/sf Deck Loads: LL 60#/Sf DL 10 #/sf Total 70#/sf Soil-• 1500 PSF Min. Concrete: Per IBC 15 Mnsonry: Per IBC 15 Steel: Per IBC 15 Hood: Per IBC 15 Nailing: Per IBC 15 4" Beam: Douglas Fir #2 fv = 180 fb = 900 PSI E = 1,600,000 6" Beam: Douglas Fir #2 fv = 170 fb = 875 PSI E = 1,300,000 Joists & Hem Fir #2 Rafters: fv = 150 fb = 650 PSI E = 1,300,000 Glu—Lam Beams: fv = 240 PSI fb = 2,400 PSI (reduced by size factor, CF•IQ) E = 1.800,000 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHITECTS.COM i i PLAN 1623 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 B-1 Date: 7/25/16 Selection 4x 10 DF-L#2 Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=2.3 in' R2=2.3 in' (1.5)DL Defl= 0.02 in Data Beam Span 6.0 ft Reaction 1 LL 960# Reaction 2 LL 960# Beam Wt per ft 7.87# Reaction 1 TL 1464# Reaction 2 TL 1464# Bm Wt Included 47# Maximum V 1464# Max Moment 2195'# Max V(Reduced) 1088# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max DO L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(in,) TL Defl(in) LL Dell Actual 49.91 32.38 0.05 0.03 Critical 24.39 9.06 0.30 0.20 Status OK OK OK OK Ratio 49% 28% 15% 13% Fb(psi) Fv(psi) E(psi x mil) Fc L (psi) Values Reference Values 900 180 1.6 625 Adjusted Values 1080 180 1.6 625 Adjustments CF Size Factor 1.200 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Lc h Shear Stress N/A m Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:320 Uniform TL: 480 =A Uniform Load A C .\1_1 R1 = 1464 R2= 1464 SPAN =6FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 1623 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 GB-1 Date: 7/25/16 Selection 5-1/8x 16-1/2 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1= 11.4 in'R2= 11.1 in (1.5)DL Defl= 0.29 in Recom Camber=0.44 in Data Beam Span 16.0 ft Reaction 1 LL 4000# Reaction 2 LL 4000# Beam Wt per ft 20.55# Reaction 1 TL 7437# Reaction 2 TL 7212# Bm Wt Included 329# Maximum V 7437# Max Moment 30942 W Max V(Reduced) 6281 # TL Max Defl L/240 TL Actual Defl L/381 LL Max Defl L/360 LL Actual Defl L/901 Attributes Section in' Shear in' TL Defl in LL Defl Actual 232.55 84.56 0.50 0.21 Critical 155.43 39.26 0.80 0.53 Status OK OK OK OK Ratio 67% 46% 63% 40% Fb(psi) Fv(psi) E(psi x mil Fc (psi) Values Reference Values 2400 240 1.8 650 Ad'usted Values 2389 240 1.8 650 Adjustments Cv Volume 0.995 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft L ads Uniform LL:500 Uniform TL: 820 =A Point TL Distance B = 1200 6.5 Uniform Load A Pt loads: R1 =7437 R2=7212 SPAN= 16 FT Uniform and partial uniform loads are Ibs per lineal ft. i CLIENT: NASH-ASSOCIATES WIND AND 5E15MIG DE516N DATA PROJECT: A R C 1 I TTF('"T'S PER 2015 15G DATE: NAME: WIND DESIGN CRITERIA DE516N PER A5GE 1-10 I. NOMINAL/ULTIMATE WIND SPEED V/asd /Vult 85/110 mph 2. RISK CATEGORY II 1.00 3. WIND EXPOSURE CATEGORY "B" 4. INTERNAL PRESSURE COEFFICIENT +/-55 5. COMPONENTS AND CLADDING DESIGN PRESSURE +/- 16 psf BUILDINGS, STRUCTURES,AND PARTS THEREOF SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN, LOAD,AND RESISTANCE FACTOR DESIGN,ALLOWABLE 5TRES5 DESIGN,EMPIRICAL DESIGN OR CONVENTIONAL CONSTRUCTION METHODS, AS PERMITTED BY THE APPLICABLE MATERIAL CHAPTER,SECTION 1604.1 BUILDINGS, STRUCTURES, AND PARTS THEREOF,SHALL BE DESIGNED TO WITHSTAND WIND LOAD5 AS DEFINED IN SECTION I&O4 AND ASGE 1-10 51MPLIFIED METHOD TO BE U5ED FOR WIND DE516N PER A--GE '7-10, SECTION 21.5 (BUILDING HEIGHT 15 LE55 THAN 160 FEET) 110 MPH ULTIMATE WIND SPED USE 14.6 P5F PER TABLE 21.6.1 "EXPOSURE B" WOOD DESIGN PER SECTIONS 2304-2306. STRUCTURES USING WOOD SHEAR WALL5 AND DIAPHRAGMS TO RESIST WIND,SEISMIC,AND ALL OTHER LATERAL LOADS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AF d PA SDPW5 AND PROVISIONS OF SECTIONS 2305-2506 5E15MIG DE516N DATA DESIGN PER A9GE 1-10/SEGTION 1613 I. SEISMIC IMPORTANCE FACTOR le 1.00 2.SHORT PERIOD AGGELERATION 59 1.66 *see footnote at bottom of page 3. 1 SECOND ACCELERATION 51 0.148 'see footnote at bottom of page 4.SITE GLA55 D (default class per IBG) 5. 5PECTRAL RESPONSE COEFFICIENT 5M OAl2 *see footnote at bottom of page 6. SPECTRAL RESPONSE C0EFFICENT 50, 0.148 "see footnote at bottom of page 1. 5EI5MIG DESIGN CATEGORY D 8. SEISMIC FORGE RESISTING SYSTEM PLYWOOD SHEAR WALL5 9. DESIGN BASE SHEAR (see seismic calculations) 10. SEISMIC RESPONSE COEFFICIENT GO 0.13 11. RESPONSE MODIFICATION FACTOR R 65 12. ANALYSIS PROCEDURE EAUIVALENT LATERAL FORGE 13. RISK CATEGORY II THE ANCHORAGE OF WAI..L5 SUPPORTING CONSTRUCTION SHALL BE BE DESIGNED IN ACCORDANCE WITH A5GE 1-10, SECTION 12.112 IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY G-F,COLLECTOR ELEMENTS AND THEIR CONNECTIONS TO VERTICAL ELEMENTS SHALL BE DESIGNED TO RESIST MAXIMUM EFFECTS AS SPECIFIED IN A5GE 1-10,SECTION 12.10.2.1 BASE SHEAR V= (P 5M/R) W ANCHOR BOLTS: 5/8" DIA X 10",A307 OR BETTER W/1" MIN. EMBEDMENT. V= 1104#/BOLT PER U565, THE MAXIMUM 51 IN THE STATE OF WASHINGTON 15 0.14&. ALL SEISMIC DESIGN VALUES USED IN THIS ANALYSIS ARE BA5ED UPON THIS NUMBER. SINGE 5115 LESS THAN 0.15,THEN USE SEISMIC CATEGORY D IF RISK CATEGORY 15 I, 11, OR III 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARC HITECTS.COM I I I I I I I I I I I I 1 I I I I I I I I i 1 I 1 I I I I 1 I I I I I I i i L N 0. �D W I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i i i I V'l N N N v N 0 � � N o x rL- N N N N - a -Sl ��J N `9 5 Q rc1 .. � � N � �. LATERAL CALCULATIONS CLIENT: NASH-ASSOCIATES PROJECT: WIND WORKSHEET A R C.I I I T F,r"r S DATE: 85 MPH/110 MPH= NOMINALNLTIMATE WIND SPIED NAME' Iq.6 P5F FRONT ELEVATION LEFT ELEVATION REAR ELEVATION RIGHT ELEVATION LOCATION TOTAL SHEAR FORCE ( ) SHEAR UNIT SHEAR W x H x (see chart for wind pressure WALL SHEAR HALL 0 specified height) LENGTH (ft) (#/ft) TYPE 1 yp /SxaklC6 z/3 � � �� y / 3 ' Zvp ll.fX� k1 q, (�,.1 ., '� //711 axIa, 6 -4 / -7 b w5q?_ ?3�-s r Z:g-I 121-611 Z� (.Isya'oQ, 4- r7g 6 q32 Z 35 lZ I� ' 2skgkrq< 61 -� cf(4rb �tjA (lQXak/ q, IS87 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW.NASH—ARCHITECTS.COM CLIENT: NASH&ASSoQATES SEISMIC ANALYSIS PROJECT: A R C f I IT I'1 l:'t'S DATE:_ NAME: 1 Weight of Building: Roof Assembly: Asphalt Shingles - 2.00#/ft Cedar Shakes - 2.25#/ft Tile - 9.50#/ft Felt - 0.15 #/ft Felt - 0.15 #/ft Felt - 0.15 #/ft 1/2" Plywood - 1.50 #/ft 1/2" Plywood - L50 #/ft 1/2" Plywood - 1.50 #/ft Trusses H) 24" o.c. - 1.75 #/ft Trusses @ 24" o.c. - 1.75 #/ft Trusses ® 24" o.c. - 1.75 #/ft R-38 Insulation - 2.35#/ft R-30 Insulation - 2.25(t/ft R-30 Insulation - 2.25#/ft. 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft Total 9.75#/ft Total 9.90#/ft Total 17.90#/ft Use 10.00#/ft Use 10.00#/ft Use 18.00#/ft 1st & 2nd Floor Assembly: Carpet / Pad - 0.50#/ft Hardwood - 2.50#/ft 3/4' MG Plywood - 2.50#/ft 3/4" T&G Plywood - 2.50#/ft 2x10 0 16' o.c. - 2.30#/ft 2x10 @ 16" o.c. - 2.30#/ft 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft. Total 7.30#/ft Total 9.30#/ft Use 10.00#/ft Use 10.00#/ft Interior Wall Assembly: Exterior Hall Assembly. 1/2" GWB - 2.00#/ft 3/4" Wood Siding - 2.30#/1t 2X4 ® 16" o.c. - 1.10 #/ft 1/2" Plywood - 1.50 #/ft 1/2" GWB - 2.00#/ft 2x6 (k�) 16" o.c. - 1.37 #/ft Total 5.10 #/ft R-21 Insulation - 2.10 /ft Use 8.00#/ft 1/2" GWB - 2.00 /It Total 9.27#/ft Use 10.00#/ft 4" Brick Veneer - + 3.20#/ft 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 W9PW.NASH-ARCHITECTS.COM CLIENT: _ =_f NASH&ASSOCIATES SEISMIC ANALYSIS PROJECT: It 4: 11 f T E.c T s DATE:. NAME: 2 SEISMIC: V = (C,) (Wdl) (plywood) 2nd LeveL• Roof: (Asphalt / Cedar Shake) 10#/ft X q� sf or (-Pile) 18#/ft X —sf =_ Exterior Walls: L x 10#/sf x 1/2 (h) 1zV,k ( 0 ky Interior Walls: L x 8#/sf x 1/2 (h) (30x?)kv( TOTAL: 1st Level•Roof: (1st Floor Roof) 10#/ft X 40 sr = goo 2nd Floor: 10#/ft X q2_D s( _ 1120O Exterior Walls: (E 2) + L x 10#/sf x 1/2 (h) 51?0 + 13 (� kl D k q(r Interior Walls: (I + L x B#/sf x 1/2 (h) 7O Y6 q(60 f OOk0i ),lpr .(11) TOTAL: � _ 3ZD_� Basement: 1st Floor: 10#/ft X sf = Exterior Walls: (E1) + L x 10#/sf x 1/2 (h) Interior Walls: (I1) + L x 8#/sf x 1/2 (h) TOTAL _ 11844 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW NASH—ARCHITECTS.COM CLIENT: NASH ASSOCIATES SEISMIC ANALYSIS PROJECT: _ ARCHITECTS DATE: NAME: 3 BASE SHEAR: BASE SHEAR V= (r- 5./W W LEVEL 2: Wdl l q- # x 0.149 = LEVEL 1: Wdl �19 1 f # x 0.149 = �rA TOTAL Wdl (?3�# x 0.149 = �� -I (V) Level Dead Load Hei ht Moment Shear ® Stor I'x = [(Wdl)(h)]�V Remarks (Wdl) (h� (Wdl)(h) (Wdl)(h) 2 LID 2g, ( f L'� Z$I ?gl (710q / Total 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) B22-1918 WWW.NASH—ARCHITECTS.COM _ CLIENT: ! HASH,ASST I T E C S SEISMIC ANALYSIS - PROJECT: ARCFIIT)✓CTS DATE: NAME: 4 Qi W O W S t\ oho O a c �x d z x�w w tv N M A a w0 VI 1 i z - w - a a 11644 N.E. 80th St Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW.NASH-ARCHITECTS.COM i - - 1 CLIENT: NASH&ASSOQATES SEISMIC ANALYSIS PROJECT: - - ARC 11ITECTS DATE: _ NAME- 6 Redundancy Factor (p):_ 1. Maximum allowable wall shear for p<=1 Vumax = (2)(Vaccstory)/Ab 1/2 2. Maximum actual shear Vmax = Largest seismic wall shear , q30 -s0fi 3. p = 2—[2(Vacc story)/(Vumax)(Ab 1/2) 2 - 1 ( liv-I-� 7"") GK �„4/V 6061 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW.NASH-ARCB TrECTS.COM i Prescriptive Energy Code Compli, - ie for All Climate Zones in Washington Project Information Contact Information Plan 1623 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition,based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Value LI-Factor Fenestration U-Factor n/a 0,30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC n/a n/a Ceilingk 491 0.026 Wood Frame Wallc "' 21 int 0.056 Mass Wall R-Value' 21/21 0.056 Floor 30 0.029 Below Grade W all"n 10/15/21 int+TB 0.042 Slab R-Value&Depth 10, 2 ft i-- n/a 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit In a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1.Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. �]2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. [J4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) la Efficient Building Envelope to 0.5 i ttticient Building Envelope 1 b 1.0 ❑ is E icient Building Envelope 1c •0 ❑ ld Efficient Building Envelope 1d .5 ❑ 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑ 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 1.0 E 1.0 31b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 1.0 5a Etticlent Water Heating 5a 0.5 0 0.5 5b Efficient Water Heating 5b 1.0 ❑ 1.0 5c Efficient Water Heating 5c 1.5 ❑ 5d Efficient Water Heating 5d 0.5 ❑ ti Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions ❑1?-1 Table R402.1.1 Footnotes For SI: 1 foot.=304.8 mm,ci .=continuous insulation, int.=intermediate framing. a R-values are minimums, U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. `"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall,or R-15 on the continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. ' Reserved. " Reserved. 'The second R-value applies when more than half the insulation is on the interior of the mass wall. I Reserved. k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. Reserved. m Int.(intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table 111402.1.3 Footnote ° Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section R402.1.3. Window, Skylight and Door Schedule Project Information Contact Information Plan 1623 Width Height Ref. U-factor Qt Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.) [4-R�H 0-01 0.00 Exempt Glazed Fenestration (15 sq. ft. max.) 1 0.01 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA House to Garage Door 0.30 1 2 16 6 17.8 5.33 Entry Door 0.30 1 3 6 20.0 6.00 Vinyl Frame Window 0.30 1 2 2 4.0 1.20 0.30 1 3 4 b 13.5 4.05 0.30 1 6 16 10 1 41.0 12.30 0.30 1 5 15 25.0 7.50 0.30 1 3 5 15.0 4.50 0.30 1 2 2 4.0 1.20 0.30 1 3 5 15.0 4.50 0.30 1 3 5 1 15.01 4.50 0.30 1 2 2 4.0 1.20 0.30 1 5 5 25.0 7.50 0.30 2 2 2 8.0 2.40 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.01 0.00 0.30 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 0.0 0.00 0.0 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 Sum of Vertical Fenestration Area and UA 207.31 62.18 Vertical Fenestration Area Weighted U=UA/Area 0.30 Overhead Glazing(Skylights) Component Width Height Description Ref. U-factor Qt. Feet '"`h Feet "'h Area UA 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.01 0.00 Overhead Glazing Area Weighted U=UA/Area 1 0.00 Total Sum of Fenestration Area and UA (for headng system sizing calculations) 1 207.3 62.18 i Simple Heating System Size:Washington State This heating system sizing calculator is based on the Prescriptive Rem iremonts of the 2015 Washington State Energy Code 1WSEC)and ACCA Mongols J and S.This calculator will calculate heatina loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30, The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC, Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need In the drop-down options,please call the WSU Energy Extension Program at (360)956-2042 for assistance. Pro'aet Information Contact Information Plan 1623 Heating System Type: @) All Other Systems 0 Heat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions Design Temperature Difference(AT) 51 AT=Indoor(70 degrees)-Outdoor Design Tamp Area of Bulidina Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 1.623 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 9.31 15,143 Glazina and Doors U-Factor X Area = UA Instructions 0.30 207 62.10 Skylights U-Factor X Area UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructions a.I, 0.026 1,034 26.88 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection `eiecc Rcnrce . -•- 1 Above Grade Walla(see Figure 1) U-Factor X Area UA Instructions 0.056 1700 95.20 LR-21 Intermediate Floors J U-Factor X Area UA Instructions R�IO 0.029 1,034 29.99 � Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions No Below Grade Welts in this pro)ect. Slab Below Grade fs•e Figure n F-Factor X Length UA Instructions 5electeond�tlonlnp . No selection F --- Slab on Grade(a.Rama 1) F-Factor X Length UA Instructions No Slab on Grade In this project. '"- Location of Ducts Instructions ` Duct Leakage Coefficient Conditioned Space J 1.00 Sum of UA 214.17 Envelope Heat Load 10,923 Btu/Hour Figure 1, SumofUAXAT Air Leakage Heat Load 8,341 Btu I Hour Volume OXXATX.OIB Abowar•d• Building Design Heat Load 19,263 Btu/Hour Air Leakage+Envebpe Heat Loss Building and Duct Heat Load 19,263 Btu/Hour Ducts in unconditioned space;Sum of Buifding Heat Loss X 1.10 Ducts in conditioned space;Sum of Building Heat Loss X i Maximum Heat Equipment Output 26,968 Btu I Hour Building end Duct HoW Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1,25 for Heat Pump (0710j/13) Date: 04/10/2026 Permit#: 1721 Perm t Date: 11/01/2017 Review Date: 11/01/2017 Perm Type: RESIDENTIAL SINGLE FAMILY Review Type: RESIDENTIAL SINGLE FAMILY Target Date: 11/08/2017 Scheduled Time 00:00 Com pleted Date: 11/02/2017 Description: Site plan m xts all land use regulations. Review Status: Assigned To: Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information Parcel#: 01166900000700 L GI HOMES -WASHINGTON LLC LGI HOMES -WASHINGTON LLC 1 450 LAKE ROBBINS DR STE 430 9032 168th Street NE T HE WOODLANDS, TX 77380 Zoning: 111 Single Fam iy Residence - DetachedLot: 7Block: Permit#: 1721 Permit Date: 11/01/17 Permit Type: RESIDENTIAL SINGLE FAMILY Project Nam e Gregory Park Applicant Nam a LGI Horn cs -Washington, LLC Applicant Address: 9028 168th Street NE Applicant, City, State, Zip: Arlingotn,WA98223 Contact: Matt Adam s Phone: 425-785-0797 Em al: m at.adam s@lgihom cs.com Scope of Work: New SFR Valuation: 205501.85 Square Feet: 1993 Num ber of Stories: 2 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/28/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wrier Nam e Ovner Phone Zoning LGI HOMES- 01166900000700 9 032 168th Street NE WASHINGTON Residence Single Dam iy -Detached LLC Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# LGI HOMES- 12951 BELRED CONSTRUCTION Labor and LGIHOHL857MB WASHINGTON LLC RD#150 CONTRACTOR Industries Inspections Date I nspection Type D escription S cheduled Date C om Iieted Date I nspector S tatus 01/22/2018 R20.SFR/DUPLEX Com Iieted FINAL Plan Reviews Date R eview Type D escription A ssigned To R eview Status 11/01/2017 RESIDENTIAL SINGLE Site plan m e is all land use regulations. FAMILY 11/01/2017 RESIDENTIAL SINGLE BUILDING FAMILY Fees Fee D escription N otes A m cunt Building Perm i T able 4-1 $2,220.14 Forced Air Heat f ee per Btu $25.00 Gas Piping/Units E nter#of units $10.00 Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base P erm i Fee $25.00 Park-Com m nity SF S ingle Fam iy $1,662.00 Mechanical Comm ecial Perm i T able 4-7;Per Unit 1 3 @$12 $156.00 Processing/Technology $25.00 State Surcharge- 1 st DU R esidential- 1 st Unit $4.50 Traffic Mitigation-SF S ingle Fam iy $3,355.00 Water Heater(Tank) $25.00 Building Perm i T able 4-1 $31.72 Building Plan Review T able 4-2 $1,443.09 Building Plan Review T able 4-2 $20.62 Total $9,028.07 Attached Letters Date Letter D escription 11/14/2017 Building Perm i Paym eats Date Paid By D escription P aym ait Type A ccepted By A m aznt 11/01/2017 LGI Hom cs-Washington Check#5720 K ristin Foster $7,532.64 LLC 11/01/2017 LGI Hom es-Woshingt C Check#5719 K ristin Foster $1,443.09 11/13/2017 LGI Hom e;-WAshington,, Check#6075 K ristin Foster $52.34 LLC O itstanding Balance $0.00 Uploaded Files Date File Nam e 11/28/2017 2803063-1721 Issued Perm i.pdf 11/02/2017 2751655-1721 Signed Application.pdf 11/02/2017 2750139-1721 Application.pdf 11/02/2017 2750141-1721 Site Plan.pdf Date: 04/10/2026 Permit#: 1721 Perm t Date: 11/01/2017 Review Date: 11/01/2017 Perm Type: RESIDENTIAL SINGLE FAMILY Review Type: RESIDENTIAL SINGLE FAMILY Target Date: 11/08/2017 Scheduled Time 00:00 Com pleted Date: 11/02/2017 Description: Site plan m xts all land use regulations. Review Status: Assigned To: Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information Parcel#: 01166900000700 L GI HOMES -WASHINGTON LLC LGI HOMES -WASHINGTON LLC 1 450 LAKE ROBBINS DR STE 430 9032 168th Street NE T HE WOODLANDS, TX 77380 Zoning: 111 Single Fam iy Residence - DetachedLot: 7Block: Permit#: 1721 Permit Date: 11/01/17 Permit Type: RESIDENTIAL SINGLE FAMILY Project Nam e Gregory Park Applicant Nam a LGI Horn cs -Washington, LLC Applicant Address: 9028 168th Street NE Applicant, City, State, Zip: Arlingotn,WA98223 Contact: Matt Adam s Phone: 425-785-0797 Em al: m at.adam s@lgihom cs.com Scope of Work: New SFR Valuation: 205501.85 Square Feet: 1993 Num ber of Stories: 2 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/28/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wrier Nam e Ovner Phone Zoning LGI HOMES- 01166900000700 9 032 168th Street NE WASHINGTON Residence Single Dam iy -Detached LLC Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# LGI HOMES- 12951 BELRED CONSTRUCTION Labor and LGIHOHL857MB WASHINGTON LLC RD#150 CONTRACTOR Industries Inspections Date I nspection Type D escription S cheduled Date C om Iieted Date I nspector S tatus 01/22/2018 R20.SFR/DUPLEX Com Iieted FINAL Plan Reviews Date R eview Type D escription A ssigned To R eview Status 11/01/2017 RESIDENTIAL SINGLE Site plan m e is all land use regulations. FAMILY 11/01/2017 RESIDENTIAL SINGLE BUILDING FAMILY Fees Fee D escription N otes A m cunt Building Perm i T able 4-1 $2,220.14 Forced Air Heat f ee per Btu $25.00 Gas Piping/Units E nter#of units $10.00 Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base P erm i Fee $25.00 Park-Com m nity SF S ingle Fam iy $1,662.00 Mechanical Comm ecial Perm i T able 4-7;Per Unit 1 3 @$12 $156.00 Processing/Technology $25.00 State Surcharge- 1 st DU R esidential- 1 st Unit $4.50 Traffic Mitigation-SF S ingle Fam iy $3,355.00 Water Heater(Tank) $25.00 Building Perm i T able 4-1 $31.72 Building Plan Review T able 4-2 $1,443.09 Building Plan Review T able 4-2 $20.62 Total $9,028.07 Attached Letters Date Letter D escription 11/14/2017 Building Perm i Paym eats Date Paid By D escription P aym ait Type A ccepted By A m aznt 11/01/2017 LGI Hom cs-Washington Check#5720 K ristin Foster $7,532.64 LLC 11/01/2017 LGI Hom es-Woshingt C Check#5719 K ristin Foster $1,443.09 11/13/2017 LGI Hom e;-WAshington,, Check#6075 K ristin Foster $52.34 LLC O itstanding Balance $0.00 Uploaded Files Date File Nam e 11/28/2017 2803063-1721 Issued Perm i.pdf 11/02/2017 2751655-1721 Signed Application.pdf 11/02/2017 2750139-1721 Application.pdf 11/02/2017 2750141-1721 Site Plan.pdf