Loading...
HomeMy WebLinkAbout9026 168th Street NE_BLD1720_2026 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development ��irN O City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9026 168th Street NE Plat: Gregory Park Lot 5 G✓1J Single-family I Duplex ❑ Townhouse ClI Addition 0I Accessory structure Proposed Area: 111 Floor: 1076 2nd Floor: 1438 Garage: 380 - Total SF: 2894 Describe Proposal (include cross street): Application for new single family residence to be located at 9026 168th Street NE. Cross street is 91st Valuation: Owner: LGI Homes - Washington LLC Address: _ _ 9028 168th Street NE City: Arlington State:WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State: WA Zip Code:98223 - Phone: 425-785-0797 Email:matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City: State: Zip Code:Arlington WA 98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 trlrw 6/16LP Page 1 of 3 jz--Y °�' RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out 9 plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) FJ`! Bath/Shower Combo (4.0) x 2 Sink(1.5) x 1 I� Shower (2.0) x Lavatory (1.0) x 5 ❑ Clothes Washer (4.0) x Water Closet(2.5) x 3 E3� Dishwasher (1.5) x 1 [6 Water Heater x 1 Q Hose Bibb (2.5) x 2 Water Heater Model # E3 Other (list) x 1 AO Smith H PTU - 50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: ABS Proposed Piping Material: PEX Proposed DWV Size: 2'' All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: �dI Furnace (80+) Model# Bryant 915SA30040514 AFUE 95% Q Heat Pump Model # SEER HSPE 0 AC Unit Model# SEER 01 Type II Hood 01 Commercial Cooking Appliance Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance PV System ❑ Fireplace Insert ❑ Outdoor BBO 0 Storage Tank Freestanding Stove Gas Piping ❑; Other Gas Piping Information Not Applicable: ❑1 Black Steel Pipe Material: Pipe Size: 1" Total BTU's of all Appliances, 120,000 Distance from Meter to Furthest Appliance: 5 • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: 6/16LP Page 3 of 3 67 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:9026 168th Street NE Permit#:1720 Parcel#:01166900000500 Valuation:309450.70 OWNER APPLICANT CONTRACTOR Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC Address: 1450 LAKE ROBBINS DR STE 430 Address:9028 168th Street NE Address: 11410 NE 124th Street,Ste#103 City,State Zip:THE WOODLANDS,TX 77380 City,State Zip:Arlingotn,WA 98223 City,State Zip:Kirkland,WA 98034 Phone: Phone:425-785-0797 Phone:360-353-0588 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Single Family Residence CODE YEAR: 2015 STORIES: 2 CONST.TYPE: `/-$ DWELLING UNITS: 1 OCC GROUP: R-3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City r' gton#3101. � _� - 1 /.2 Signature Print Name Date Released By tc CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/14/2017 Building Permit Fee $3,076.58 11/14/2017 Building Plan Review Fee $1,999.78 11/14/2017 Furnace $25.00 11/14/2017 Gas Outlets Base Fee 1 to 5 $10.00 11/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00 11/14/2017 Mechanical Permit Base Fee $25.00 11/14/2017 Park-Community SF $1,662.00 11/14/2017 Plumbing Permit Base Fee $25.00 11/14/2017 Plumbing Permit Fee(Enter Fixture Fee) $192.00 11/14/2017 Processing/Technology Fee $25.00 11/14/2017 State Building Code Surcharge Fee $4.50 11/14/2017 Traffic Mitigation-City $3,355.00 11/14/2017 Water Heater $25.00 Total Due: $10,449.86 Total Payment: $10,449.86 Balance Due: 50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BYTWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9026 168th Street NE Plat: Gregory Park Lot 5 _ 41 Single-family Duplex Townhouse Addition DI Accessory structure Proposed Area: 111 Floor: 1076 2nd Floor: 1438 Garage: 380 Total SF: 2894 Describe Proposal (include cross street): Application for new single family residence to be located at 9026 168th Street NE. Cross street is 91st Valuation: `�"J� •�o Owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 _ Phone: 425-785-0797 Email: matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State: WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC 9028 168th Street NE Arlington WA 98223 Address: City: State: Zip Code: Phone: 425-785-0797 Email: matt.adams@lgihomes.com � Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 —6116LP Page 1 of 3 y RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development N City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) Bath/Shower Combo (4.0) x 2 [6 Sink (1.5) x 1 [✓}; Shower (2.0) x 1 [41 Lavatory (1.0) x 5 Ui Clothes Washer (4.0) x Water Closet(2.5) x 3 911 Dishwasher (1.5) x 1 al Water Heater x 1 14 Hose Bibb (2.5) x 2 Water Heater Model # 91 Other (list) x 1 AO Smith H PTU - 50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: AB Proposed Piping Material: PEX Proposed DWV Size: 2" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 y, RESIDENTIAL PERMIT APPLICATION •y Department of Community& Economic Development ING,10 City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: � Bryant 915SA30040514 95%! Furnace (80+) Model# AFUE ❑ Heat Pump Model# SEER HSPE ❑ AC Unit Model # SEER Type ll Hood ❑ Commercial Cooking Appliance D1 Hydronic Piping Boiler ❑ Solid-Fuel Appliance El! PV System ❑1 Fireplace Insert ❑ Outdoor BBO Ell Storage Tank ®I Freestanding Stove L—d' Gas Piping 01 Other Gas Piping Information Not Applicable: ❑j Black Steel Pipe Material: Pipe Size: 1 Total BTU's of all Appliances 120,000 Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: 6/16LP Page 3 of 3 168TH ST. N� SETBACKS NOTES: FROWT 10' •BUILDING D/A/ENSJ'GWS ARE 70 ` 8'WA7ER 57DE 5' FACE OF FOUNDADAN I/ REAR 5' •OWADING-WONN AS DE96W A07UAL LOCA710W IIAY VARY 3t00 2 •gwi Dim vAY 76 PUBLIC ROAD 8'SENOP' ; •-%T fEN6F TO BE INSTALLED PER 2w NAM? aTY OIL ARL/NG7OW S STANDARD OY�YYNECAOW �yQc •57L T fEW TO BE INSTALLED ON I 6RAD/ENT 570E OF BUILUNG PARLL4 • •COW67RU071OW ENIRM6r TO BE INSTALLED PER a7Y OF 45.00 e a • d ARLINGTLW S STANDARDS l N89 0'49°W e ' PRA°OP1Y STORM NOTES: s •7EX INSTALLED PR16R TO S7WM LEOlVr OLYPNa(7YP. CMSMUCnOW COWNECT ROIL AND 2R010' e °e •BARE SaLS CO RED W7H MULal ,FOOANG ORA S I BSBL ?600' Sae'AW0117E OP ANOINER APPROWD BIIP ST" •IOW56W PER N500E B,UP T5.13 — — 00' a 471 SJr EASfMT TOP,470.5 11.019 wiEWgY ��— — — — GWSIIE R NA�F COM/NECIED TO 3 TOE 46Z5 I ti% °e; . t.. 112 VI RUBL/C PR/YAX STOW SW i I 24.00 UnV1Y •21E-WALL BE STABILIZED PRIOYP Ate, I EAM)MVT TO BUILDING PE7PAllT BONG RNAUZEO 1.00'R 04fRHANf ! gU NG I S/TE NOTES.• g a17UNE I •AA'lAJNE F0077NG DRAINS AND ;g i $ ROOF DRAINS 70 POPIIANEIVT P 470.5 + V ��, I S7ORM DRNNAOL'SY57Al POP _ APPROkEV PLAT DRA/NAX PLAN '3 TOE 46Z5 - LOT 5 i OW RLE W7H 7HE CAUNTY. 1000'WA141PRNN� PRa-09�D RE�'IDENOE cV •AREA OF L�/S1URB,4NQ�INGYUDES EASEMENT PALI X-2514 GARAGE''R167lT oo I ENURE LOT. 1,679t- = I LEGEND: 3500 I W— BLOW OFF \ f (10` e I 15010 ® NAIER ABM II II PATlO 12 SF I 0 FIRE HYDRANT TOP 470.5 '-5.010 BSBL 5A0 BSBL� I � AIR YAC 3 TOE 46Z5 I I g7SnNG i I I ® CATai BASIN COYTOUR(IYP.) I I O a£ANOY/T f IED Cavmwx I I O MANHOLE (rip) I I 071T7-FT] &Off WALL o I I qj \ .�t,i� 7REE REMOVAL I - I - IF Received I I I I I OCT 31. 2017 SCALE I'm 20' -- - - — J Liz Sae' I I 7 LOT 5 45.00�� i N8970'05"W SITE PLAN GREGOR Y RA RK LG/ HOMES PLAN NO. PAL/X-2514 LOT AREA = 5,,786 SF DATE 101212017 PARCEL # LOT 5 HOUSE= 1,679 SF 11711 NE 291h Place,#I01 DRIWWAY= 471 SF Bellevue,W,,hi,glon 98007 DESIGNED CORE ADDRESS 9026 1687H Sr j 425.885.7877 Fax 425.9957963 WALKWAY/PA770 = 12 Sr PROJECT NUMBER TOTAL= 2,162 SF ENGINEERING PLANNING • SURVEYING DRAWN CAF 13024L-GRG00 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 42 PHONE; (360)403-3551 BUILDING PERMIT Address:9026 168th Street NE Permit#:1720 Parcel#:01166900000500 Valuation:309450.70 OWNER APPLICANT CONTRACTOR Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC Address: 1450 LAKE ROBBINS DR STE 430 Address:9028 168th Street NE Address: 11410 NE 124th Street,Ste#103 City,State Zip:THE WOODLANDS,TX 77380 City,State Zip:Arlingotn,WA 98223 City,State Zip:Kirkland,WA 98034 Phone: Phone:425-785-0797 Phone:360-353-0588 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Single Family Residence CODE YEAR: 2015 STORIES: 2 CONST.TYPE: `/-B DWELLING UNITS: 1 OCC GROUP: R-3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX N077CE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and c�ty r' gton#3101. s �� Signature Print Name Date Released By to CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES _ Date Description Fee Amount 11/14/2017 Building Permit Fee $3,076.58 11/14/2017 Building Plan Review Fee $1,999.78 11/14/2017 Furnace $25.00 11/14/2017 Gas Outlets Base Fee 1 to 5 $10.00 11/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00 11/14/2017 Mechanical Permit Base Fee $25.00 11/14/2017 Park-Community SF $1,662,00 11/14/2017 Plumbing Permit Base Fee $25.00 11/14/2017 Plumbing Permit Fee(Enter Fixture Fee) $192.00 11/14/2017 Processing/Technology Fee $25.00 11/14/2017 State Building Code Surcharge Fee $4.50 11/14/2017 Traffic Mitigation-City $3,355.00 11/14/2017 Water Heater $25 00 Total Due: $10,449.86 Total Payment: $10,449.86 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the lollowing information: Permit Number.Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTONI IVI r-f4 I II r R A VED I 168TH ST. NE f7 vrAC�n NOWS: \ B'wA7t7P s"F 5', fflM VC LIMVV.WC ARE'70 DATE Or FOf,4U7A MY DATE REAR 5' -Q?AZIW AM AS LFsyGiV a A07YAL LOG7w AUY YARY O GES UTHORIZED •maw LV7W AY M PI.EW Raw 8"MVUP 2f •St r fDVLT 7D dE AYSTAUM PIER UILDRIG I FAM? a7YOrARLAV WFSrAA0ARID •SET fDYLF 70 bF WhAUM ON Q?AZN9Vr WE Or Bt"W PA&R 1 Y ,COKS7RlVWV WRAW 70 bF 4 -�-_ - — A�GrdAIL�L�EyDy�rP+E�� ,alrY 6F d • d • o' 45,(/t/• A• B .A /MTLIAV r J STA DAITi/.7� N89 20..'49"WT STORMNOTES.-- — ! P1iL'?'E]P7Y •TESL^AVSTALLm PR70? 7D slta?AI T ' OL1�1V(TW G1�YS7RULlICW Li�V1 0 Rotr k? rXJ' - - — �BARE RALS CO10M WN AOVAal ,f7JID1AVC A? I 1tS00' SOD'H1PIYAIE O?AN0#a APlw;o ar S7LIfl1/ •Tta°,57aC PLR MWff AV 15 1d ----- - 192Lgj J EA.SEIo;,_I 07FFIrww) 470.5 ILOD - r Y . — t •ALL LAVtA17E.%,WF(x111VEC7M 70 3 TOE 467.5 i $ ' • '..-- _ la00'P(&K' — — PAYWE S7W SW `d 24 W U7vTY .97E wALL BF STAbitr=Pmw EA.ST,iENT rO"OW P!wr bqw I f7NAU2ED 1.A?'Rq SITE NOTES.• $ b I d AIAV7&E fDOW LRAW AW "470.5 MAaF P'Rl PERTJ — j A9°7 OU PLAT LRWAaF_ ��'S LW fl'.E W7H AE COWlY. 1aLn'w�,�rNiv REs�govc�- I •AREA Or LYSRA?fiGI/ar AI%UM EAS NT 1 P14UX--2514 Crll+'AGE Rfq'lT o I I EN1A4E LOT. Ii 679�t Z I L EGEND.- ,SLID i I ' o- BLOW 4°F Sao, EB W17ERAEEU i PA 12 SF 4( fw H)vRANT 3 7t7P 470 5 � 5� bt56ir v; BSK AR PAC 127E �� ll ,Q7S11NC I I CA7L7l BASifV aWMw(7W.) I I 1 O aEowr aYwrow I I 1 Q maw &=WALL o � 7AEF AWYAL Received 3 1. (,U 1 I sa4a 1'-AID' -- - ' LOT 5 45.00X ' N8970 05'W,)- • SME PLAN GREGOR Y PARK LGI HOMES PLAN NO. PALIX-2514 LOT AREA = 5,,788 SF DATE 1012/2107 PARCEL LOT 5 HOUSE= 1,67Y Zw 147?114E 29th Pl-.,9 10 1 DRIWWAY= 471 Sf "18001 DESIGNED CORE ADDRESS 90B IM7H ST. ALF 475.BBS 475 7B77 Fan 885.79d7 WADYWAY/PA#0= 12 SF ��"ski" PROJECT NUMBER 7L1TAL= 2,J62.� ENGINEERING • PLANNING • SURVEYING DRAWN CAf 13024L-GRG00 t ....r...�.moo-r' frl I Permit Information Date 11/1/2017 Permit Number 1720 Project Name Gregory Park Applicant Name LGI Homes-Washington,LLC Applicant Address 9028 168th Street NE City, State,Zip Arlingotn,WA 98223 Contact Matt Adams Phone 425-785-0797 Email matt.adams@lgihomes.com Permit Type Single Family Residence Site Address 9026 168th Street NE Valuation 309450.70 Status Applied Permit Issued Permit Expires Square Feet 2894 Type of Construction/Occupancy Load V-B Number of Stories 2 Proposed Use New SFR Assigned To Kristin Foster Property Owner Parcel Address Legal Owner Phone Zoning 01166900000500 9026 168th Street LGI HOMES-WASHINGTON 111 Single Family Residence- NE LLC Detached Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type LGI Homes-Washington..lake Jabusch 360-353- ake.jabusch@Igihomes.co CONTRACTOR (Labor and I_GIHOHL857M LLC0588 (Industries Review Date Type Description I Target Date I Completed Date I Assigned To Status 11/1/2017 lResidential Dwelling 11/8/2017 my Rusko In Review 11/1/2017 lResidential Dwelling 11/8/2017 Kevin Olander In Review Fees Fee Descri tion Notes Amount Building Permit Fee 322.10.00.001 $3 076.5 Building Plan Review Feel 345.83.00.00 $1,999.7 Furnace 322.10.00.00 $25.00 Gas Outlets Base Fee 1 to 51 322.10.00.00 $10.0 Mechanical Fee(Enter Fixture Fee)j 322.1 0.00.Oq $25.00 Mechanical Permit Base Feel 322.1 0.00.Oq $25.0 Perk-Community SEFJ 345.85.MOq $1,662.00 Plumbing Permit Base Feel 322.10.00.00 $25.00 Plumbing Permit Fee Enter Fixture Fee 322.10.00.00 16 @$12 $192.0 Process in fTech no ogy Feel 341.43.00.02 $25.00 State Building Code Surcharge Feel 386.00.01.00 $4.50 Traffic Mitigation-Cityl 345.85.00.02 $3,355.00 Water Heatel 322.10.00.00 $2600 TotaQ $10,449.8 Payments Date Paid By Amount Description Payment Type Accepted B 11/1/2017 ILGI Homes-Washington LLC $1.999.7 heck#5716 Kristin Foster 11/1/2017 ILGI Homes-Washington LLC $8,450.08 ICheck#5717 Kristin Foster Total $10.449.86 Amount Outstanding:$0.06 Notes Date Note 11/1/2017 Application needs signature.KF Uploaded Files Upload File Date File Uploaded B 11/1/2017 2:24:58 PM 1720 Site Plan Pdf Foster, Kristin X 11/1/2017 2:24:58 PM 1720 Application.odf Foster,Kristin x RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9026 168th Street NE Plat: Gregory Park Lot 5 . 01 Single-family ❑± Duplex ❑ Townhouse ❑ Addition Ch Accessory structure Proposed Area: 151 Floor. 1076 2" Floor: 1438 Garage: 380 Total SF: 2894 Describe Proposal (include cross street): Application for new single family residence to be located at 9026 168th Street NE. Cross street is 91st Valuation: _' 4'01 •�� Owner: LGI Homes - Washington LLC 9028 168th Street NE Arlington WA 98223 Address: City: State: Zip Code: Phone: 425-785-0797 Email: matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State: WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 Vr7mo 6116LP Page 1 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development °A Or City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out 'rf plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) �I! Bath/Shower Combo (4.0) x 2 Sink (1.5) x 1 [� Shower(2.0) x 1 Lavatory (1.0) x 5 ❑ Clothes Washer (4.0) x Water Closet(2.5) x 3 Dishwasher(1.5) x 1 9� Water Heater x 1 4 Hose Bibb (2.5) x 2 Water Heater Model # 91 Other (list) x 1 AO Smith H PTU - 50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: AB Proposed Piping Material: PEX Proposed DWV Size: 2" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development y' O ING1 City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 � Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: 0 Furnace (80+) Model# Bryant 915SA30040514 AFUE 95% Heat Pump Model# SEER HSPE ❑ AC Unit Model# SEER 0; Type II Hood ❑ Commercial Cooking Appliance U Hydronic Piping 01 Boiler ❑ Solid-Fuel Appliance D PV System Ql Fireplace Insert 0 Outdoor BBQ ❑; Storage Tank 10 Freestanding Stove 4 Gas Piping 0; Other Gas Piping Information Not Applicable: Black Steel Pipe Material: Pipe Size: 1" Total BTU's of all Appliances: 120,000 Distance from Meter to Furthest Appliance: 5 • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: 6/16LP Page 3 of 3 R�. -- - y- cl i ! . � � � » 7 ® z - U) ] � . 640-00 04M � rno* 22@w� i ®M »/ ## w / § §z r 0««?SK//¥ § e_r - \=r o = k =c � / m — } � ����_�\_e___� ` v r 1 t. V'N4I11V 204040 N 4-D0-OO } a B1 Al im Fl 8-00-00 � az C IA IA A g 3 r a o c - 'r 14-10-04 5-03-12 4-00-W 4-00-00 17-10.00 8-00.00 r yym tr7 c r n y r A o 00 0 O r_ Y"fir r C F t:o 11-4-0 D.Cw"9 Do.*.01 Bulltler LGI HOMES ]ob Number Sheet T"', BMCI' Argue M NE Ew ,WAI eBAI ]ob Neme/Motlel 2519-FL D-Ignar DAN C. TRUSS LAYOUT a OFOe Q67893iA0 x ^ ov��tNt�N/p�+X<so�lw--!tVA0NhIw<%wm Atler.e:: Deee 5/e/2017 M!Tek MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA,95610 Telephone 916/676-1900 Re: 2514-FL Fax 9161676-1909 LGI HOMES 2514 FL The truss drawing(s)referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by BMC West-Everett,WA. Pages or sheets covered by this seal: R50499425 thru R50499441 My license renewal date for the state of Washington is May 16,2019. V1ERmL 6 oF wAs� �'°tea X� 0 .off R 51398 q� ��' `ACISTELz� 8I May 8,2017 Baxter,David IMPORTANT NOTE:Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. Job Truss TI ,pa Qry 71YLG :S 2514 FLR50499426 2514-FL A2 Floor 9 Reference o ttonal BMC. EVERETT,WA 98205-3212 8.030 s Jan 23 2017 Mi fek Industries,Inc. Mon May 08 13:21:39 2017 Page 1 ID:migzTLjh7H 1 sSQCF VTnRO6zlaVJ-LwSaFxrw2TL.k_wWKuFgvMolOgPhhgTdFDgaxt6zIYZA 0-1-8 H 12— Scale=1:31 6 4x8= 3x4= 3x4= 48= A B C D E F G H 0 P N M L K 3x6= 4x12 = 3x4= 4x12 = 3x6_ 19-3.0 194-0 Plate Offsets(X Y)— fA:Edge 0-0-121 IFO-1-8 Edgel fM 0.1-8 Edged IP:0-1-8 0-0.12) fQ:0.1.8 0 D 12I LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d FLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 073 Vert(LL) -0.33 M-N >686 480 T20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.99 Vert(CT) -0.49 M-N >470 360 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(CT) 0.09 J n/a n/a BCDL 50 — Code IRC2015lfP12014 Matrix-R _ Weight:77 Ill FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins, BOT CHORD 2x4 HF No 2(flat) except end verticals. WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing REACTIONS. (lb/size) 0=1045/0-5-6,J=1045/0-2-10 FORCES. (lb)-Max Comp/Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-2894/0,C-D=-2894/0,D-E=3563/0,E-F=-356310,F-G=-2881/0,G-H=2881/0 BOT CHORD N-0=0/1719,M-N=0/3506,L-M=0/3563,K-L=013563,J-K=0/1714 WEBS 8-0=-1951/0,B-N=0/1333,D-N=-695/0,D-M=2621428,H-J=-1945/0,H-K=0/1325,G-K=-276/2,F-K=-912/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. A-Y of WAS '�f N . O vt 51398-10 �+4 STS �} �sstONAL��� May 8,2017 a&WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.1010312015 BEFORE USE. Design valid for use only with MrTok®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the binding designer must verify the applicability of design pammeters and property Incorporate this deson into the overall building design Orawig indicated is to prevent buckling of individual burn web and/or dwrd members only.Additional lensW by and pamauenl lxaciny 91 A pTia Ir'- --- - is always required formability and to prevent collapse with possible personal injury and property damage. For general guidance regard"the RV 99 fek fabnca0on,storage,delivery,erection and bracing of trusses and Imss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Sarety Information available from Truss Plate Institute.218 N,Lee Street,Suite 312.Alexandria,VA 22314. Suite 109 14r I h A 9 10 Job JA4 uss Tn. ae Qty Piy LGI I S 2514 FL R50499428 2514-FL Floor 2 1 Job Reference(optional) BMC. EVERETT,WA DS205.3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Man May 0813:21AI 2017 Page 1 ID:migzTL)h7H 1 sSQCFVTnR06ziaVJ-HJaKgdsAa4bSODgi?gsNRDOQnDPk80mYhT32y?rJYZ8 0-1-8 H 1 2-8-0I-- 1-3-0 i 1-3-0 n`I`--� Scale=1:29.9 4x8= 3x4= 3x4= 4x6= 3x4 11 48 11 A B C D E F G H I J SJ P O N M L K 3x6 = 4x8= 3x4= 4x8= 5x8= r 17-6 12 7 9 12 17.8 12 Plate Offsets(X,Y)-- [A:Edge 0-0-121 fF:0-1-8 Edae1 (J•0-3-0 Edael [O:0-1.8 Edael (R:O-1-8 0 0-121 [S:0-1 8 0-0 121 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 100 TC 0.51 Vert(LL) -0.24 O-P >883 360 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.88 Vert(CT) -0.35 O-P >597 240 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(CT) 0.01 J file nla BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:76 lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No 2(flat) except end verticals WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. (lb/size) J=952/0-2-14,Q=952/0-5-6 FORCES. (Ib)-Max.Comp,/Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD B-C=-2549/0,C-D=-2549/0,D-E=2884/0,E-F=-2884f0.F-G=2515/0,G-H=-2515/0,1­1-1=811/0,I-J=-814/0 BOT CHORD P-Q=0/1546,0-P=0/2988,N-0=0/2884,M-N=0/2884,L-M=0/1541 WEBS J-L=0/1176,B-Q=-1755/0,B-P=0/1137,D-P=-498/0,D-0=340/240,H-L=1057/0,H-M=0/1106,F-M=-660/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0.0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7)CAUTION,Do not erect truss backwards. tAE�1 6 WAS1rtr �7� R 51398 S`SjONALG May 8,2017 q®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTeki&connectors,This design is based only upon parameters shown,and Is for an individual budding component,not o tress system.Before use,the building designer must vanity the applicability of design parameters and property incorporate this design into the overall bwlding design Brafing ne0icalrnl+b to prevent buGAlerg of uWivrduel hu»wnu andlm JwW nremWis uuly.lWddiurwl lenryenmy and pmuuntunt In ta:hlg is Ql.7,Ta,� always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the !V! 1 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSVTPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plato Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Hr sCA B561 11� �� � i� Job Truss Tn pe Qty Ply LGI 1. S 2514 FL t n R50499429 2514-FL A5 FLOOR 3 1 Job Reference o BMC. EVERETT,WA 98205-3212 8.030 s Jan 23 2017 M iTek Industries,Inc. Mon May 0813:21:42 2017 Page 1 I0:mIgzTL1h7H1sSQCFVrnR06zfaVJ-mVSIWpLOIJrNFYW14q Rwalcgitgztw7ocURzIYZ7 0-1-6 H 2-6.0 -- 1-3-0 Scale=f:2 0lr2 9.0 4x8 = 3x4 = 3x4= 4x8 = A B C D E F G H I Q 16 m P j� 7!!� LN N M L K 3x6= 08= 3x4 = 48= 3x6= 17-9-12 17.9-12 Plate Offsets(X Y}- fA:Edge.0-0-121 fF0-1-8 Edgel fM:0.1-8 Edoel fP:0-1-8 0.0.121 IQ:0 1 8 0-0 121 [R:0.1-8 QA-121 fS-0-1-8 0-0-121 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1 00 TC 0.56 Vert(LL) -0.25 M-N >826 480 MT20 185/148 TCDL 100 Lumber DOL 1.00 BC 0.90 Vert(CT) -0.37 M-N >558 360 BCLL 0-0 Rep Stress Incr YES WB 0.37 Horz(CT) 0.07 J n/a n/a BCDL &0 Code IRC2015/TP12014 Matrix-R Weight:73lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 0=959/0-5-6,J=959/0-3-6 FORCES. (lb)-Max,Comp/Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-257410,C-D=-2574/0,D-E=-7.92610,E-F=-2926/0,F-G=2547/0,G-H=2547/0 BOT CHORD N-0=0/1560,M-N=0/3026,L-M=0/2926,K-L=0/2926,J-K=0/1558 WEBS B-0=-1770/0.B-N=0/1152,D-N=-513/0,D-M=-340/251,H-J=1768/0,H-K=0/1122,F-K=672I0 NOTES- 1)Unbalanced floor live loads have been considered for this design, 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise Indicated. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. UQ C�0 51398 qr� �SsjONALG May 8,2017 WARNING-VerW design paametera and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with A4TekP connectors.This design is based only upon parameters shown,and Is for an individual bulidmg component,not a buss system,Before use,Ine budding designer must vent'the applicahility of design parameters and property incorporate this design into the overall building design. Oratlng indicated Is to prevent buckling of i"d ldual buss web andlof chord members only.Additional temporary and pemwront bracing is always required for slat4ldy and to prevent collapse with possible personal injury and property damage For general guidance regarding the MiTek' fatincation,storage,delivery,erection and bracing of trusses and buss systems,see ANSIITP11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available born Truss Plato Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 rus tj9Lqbjj.CA 25610 i e � 1 - I Job Truss Tfu, pe Qy, IP17YLMlR�, S 2514 FLR50499430 2514-FL A6 GABLE 1 eference optlonal) BMC, LVEREii.WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:43 2017 Page 1 ID:migzTLjh7H1 sSQCFVTnROBziaVJ-Ehi55JuR6lrASXg578urMTgsOHicMWr8nY90tzlYZ6 0-[8 ops Scale=1:28.6 A B C D E F G H I J V X 0 m U W T S R Q P O N M L K d 2 0 0 4-0-0 8-0-0 8 0 0 10-0-0 12-0-0 14 0.0 18-0-0 17 9 1 2-0-0 2 0-0 2-0.0 2-0 0 2 0 0 2-0 0 2-0-0 2-0-0 1 9.12 Plate Offsets(X,Y)- [A.Edge 0.0-121 [U:0-1-8 0.0-121 [V:0-1.8 0-0-121 [W.,0-1-8 0.0-121 [X:0-1-8 04)-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TIC 0.15 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 003 Horz(CT) 0.00 K n/a n/a BCDL 5.0 Code IRC2015rrPI2014 Matrix-R Weight:58 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing OTHERS 2x4 HF No.2(flat) REACTIONS. All bearings 17-9-12. (lb)- Max Grav All reactions 250 Ib or less at joint(s)T,K,S,R,Q,P,O,N.M.L FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web) 5)Gable studs spaced at 2-0.0 oc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. jp"uz S 51398� qa .�, GIST'SR sst�NAL��� May 8,2017 -: _ ®WARNING-Varfry design paramsfers and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 111111 1 raa.140MO1S BEFORE USE. Design valid for use only with MITek®connectors This design is based only upon parameters shown,and is for an Individual building component,not a truss system.Before use,the building designer must verity the apilf cabikty of design parameters and properly incorporate this design into the overall building design.bracing indicated is to prevent buckling of individual truss wab and/or chore members ony.Additional temporary and permanent bracing MiT� is always required for stability and to proven!collapse with possible personal injury and property damage. For general guidance regarding the 1V1 tle fabrication,storage,delivery,erection and bracing of trusses and buss systems,see ANSUTF41 Quality Criteria,OSS-89 and SCSI Building Componefn 7777 Greenback Lane safety Inforritallon available from Truss Plato institute,218 K Lee Street-Suite 312.Alexandria,VA 22314 Suite 109 itrlrs Hai Ms CA 956f0 � if T r Job ::[�C_"fi . Ipe Qty PTJ,b F. eS 2514 FL q R50499431 2514-FL BLE 1 eference o ffanal BMC, EVERETT,WA 98205-3212 8,030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:44 2017 Page 1 10:migzTLjh7m 1sSQCFVrnR06zlaVJ•iuGTl(u31?zl4hPHhOQ43s09VQdnLpm_NRHiYJziYZS 0*8 Scale=1:33,2 3x6 FP= A B C D E F G H I J K L M �B X X X X 5ffKZ Z,A A A A - - - - - - - - - - - - X X X'g X f:: D AA Z Y X W V U T S R Q P O N 3x6 FP= 2 8 12 4 8 12 e 8 12 8.8-t2 10 8 12H 12 8.12 14 8 12 l 16 8 1 � 18 8 12 20 8 8 -11221 2 0-0 2-0-0 2-0-0 2-" 2-0.0 2.0-0 2-0.0 2-0-0 2-0 0 1 11 12 Plate Offsets(X,Y) 1A.Edge 0.0-121 (AA 0-1 8 0-0-121 [A6 0-1-8 0.0-121 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) i/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 100 TC 016 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.03 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 N n/a nla BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:67lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No 2(flat) REACTIONS. All bearings 20-7-0. (lb)- Max Grav All reactions 250 Ib or less at joint(s)Z,N,Y,X.V.U.T.S,R,Q,P.0 FORCES. (lb)-Max.Comp./Max Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web) 5)Gable studs spaced at 2-0.0 oc. 6)Recommend 2x6 strongbacks,On edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. t L 8 51398 �sst�NAL�yG May 8,2017 f.,WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTokili connectors.This design is based only upon parameters drown,and is for an Indivlduat building component,not a truss system Before use,the building designer must verity the appticability of design parameters and property incorporate this design into the overall -building design Bracing indicated Is to prevent buckling oft truss web andlw chord members only. Additional temporary and permanent bracing Owe r�• is always required for stability and to prevent collapse with possible personal Injury and property damage For general guidance regarding trio fabrlcalion,storage,delivery,wection and orating of trusses and truss systems.see ANSIITP11 quality Criteria,OSB-89 and SCSI Building Component 77T7 Greenback Lane Safety Information available from Truss Plate Institute,21lt N Lee Street,Suite 312,Alexandria.VA 22314. Suite 109 Citrus Het h A 956f0 � ti: '� Job Truss 7ru pe Qty Ply LGI I•, _S 2514 FL 1 J 2514-FL 82 Flow5 1 R5049943 _ Job Reference o Iona! BMC, EVERETT,WA98205.3212 8.030 s Jan 232017 tWTek Industries,Inc. Mon May 08 13:21:45 2017 Page 1 ID:migzTLjh7H1sSQCFVTnRO6zlaVJ-A4prW7vheJ5uir TEVxJb3Y4SgoB4AZ8c51G5mzIYZ4 'r 280 1-3-0�i 1-1-0'—I 0*8 Scale=1:33.8 4x8= 3x6= 3x4= 3x6 FP= 4x8 = A B C D E F G H I J K T o S 3x10= Q P O N M 3x6 FP= 3x4= 3x4= 4x12 = 3x6= 4x12= 041.8 20.8.8 Plate Offsets(X,Y)— WEdae.0.0-121 IN:0-1-8 Edgel 10:0-1-8 Edgel 1S:0.1-8 0-0-121 IT:0-1-8 0.0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ltd PLATES GRIP TCLL 40.0 Plate Grip DO 1.00 TC 0.53 Vert(LL) -0.35 M-N >700 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.72 Vert(CT) -0.50 M-N >492 360 BCLL 0.0 Rep Stress Incr YES WB 0.44 Horz(CT) 0.09 L n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:89lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat)"Except" TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, A-I:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) except end verticals. BOT CHORD 2x4 HF No.2(flat)'Except" BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. L-Q:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) WEBS 2x4 HF No.2(flat) REACTIONS. (lb/size) L=1125/0-5-6,R=1125/0-2-10 FORCES. (Ib)-Max.Comp./Max.Ten.-AIf forces 250 1 or less except when shown. TOP CHORD B-C=-3190/0,C-D=-319010,D-E=4'170/0,E-F=-4170/0,F-G=-417010,G-H=-3192/0, H-J=3192/0 BOT CHORD P-R=0/1861,O-P=0/3946,N-0=0/4170,M-N=013952,L-M=0/1868 WEBS J-L=-2120/0,B-R=-2112/0,J-M=0/1502,B-P=0/1508,C-P=-261/0,G-M=-863/0, D-P=-857/0,G-N=-158/586,0-0=108/612,E-0=-326/38 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to bearing plate at joints)R. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. OF WAS. 51398 cy4 NAL �� May 8,2017 ;L WARNING-Vil lly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-T477 rev.1010312015 BEFORE USE. Design valid for use only with MITel connectors This design is based only upon parameters drown,and Is for an individual building component,not a Inks system Before use,the budding designer must vent'the applicability of design parameters and properly incorporate this design into the overall - -buatlmg design.cirac ng indicated is to prevent Duckling or individual truss web andfor chord members only, Adaalonal temporary and permanent bracing_ --- -- wt 1� iT�l� i\ Is always required for slabildy and to prevent collapse with possible personal Injury and property damage For general guidance rdgaMing the 1 V.r l fabrication,stooge,dellvary,erection and bracing or trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safely Informalion available((am Truss Plate Institute,218 N Los Street,Sude 312.Alexandria,VA 22314. Suite log a -Hai t: 10 ��, �1 ,- I I Job 1TV78 Tn, pe Qty ply LGI F S 2514 FL 2514-FL R50499433 Floor 5 1 Job Reference(optional) BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MITek Industries,Inc. Mon May 0813:21.46 2017 Page 1 I D:migzTLih7H t SSQCF V TnRO6zlaVJ-eGNDJKwJPdDIJ_YgoDSYSH5EPE8ypcgHglmpdC?JYZ3 2-6-0 1-3-0 i 1i�0-a-6 Scale=1:3T5 4x8= 3x6 FP= 3x4= 3x6 = 4x12= 3x4 11 3x4= A B C D E F G H I J K L V o tb U T S R Q P O N M 3x6 = 4x12 = 3x4= 3x4= 3x6 FP= 4x12 = 4x1220-7-2 = 20• 1 -6.8 20-7.2 C- •8 1.11-14 1 Plate Offsets(X,Y)— (A:Edae 0.0-121 fL:0-1-8 Edaei (Q:0.1-8 Edoel IR-0-1-8 Edael fU•0-1 6 0.0-121 N'0 1 8 0 0-121 LOADING (psf) SPACING- 2-0-0 CST. DEFL. in (loc) IJdefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.58 Vert(LL) -0.36 P-Q >688 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.75 Vert(CT) -0.48 P-Q >513 360 BCLL 0.0 Rep Stress Incr NO WB 0.45 Horz(CT) 0.08 N n/a n/a BCDL 5.0 Cade IRC2015ITP12014 Matrix-R Weight:99 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr(flat)"Except" TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, A-D:2x4 HF No.2(flat) except end verticals BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat)"Except' BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. M-0:2x4 HF No.2(flat) WEBS 2x4 HF No.2(flat) REACTIONS. (lb/size) T=1087/0-2-10,N=1711/0-5-8 Max Grav T=1104(LC 3),N=1711(LC 1) FORCES. (lb)-Max.Comp./Max.Ten.-All forow 250(lb)or less except when shown. TOP CHORD B-C=-3108/0,C-E=-310810,E-F=-4021/0,F-G=-4021A G-H=-4021/0,H-1=-2949/0, I-J=-2949/0,J-K=0/555,K-L=0/552 BOT CHORD S-T=0/1823,R-S=0/3828,Q-R=0/4021,P-Q=0/3751,N-P=0/1582 WEBS K-N=-265/0,B-T=-2069/0,B-S=0/1459,C-S=-256/0,J-N=-2165/0,J-P=0/1591, H-P=-944/0,H-Q=-98/668,E-S=-817/0,E-R=-171/569,F-R=-302/71,L-N=-67710 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)T. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard L 8 1)Dead+Floor Live(balanced):Lumber Increase=1 00,Plate Increase=1 00 Uniform Loads(plf) Vert:M-T=10,A-L=-100 Concentrated Loads(lb) Vert:L=-328 S�ONAL May 8,2017 WARNING-Verify,design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTaAW connectors This design Is based only upon parameters shown,and is far an individual building component,not , a truss system.Before use.the budding des,gner must verify the applicability of design parameters and property Incorporate this desiqn Into the overall budding oougn time always trig euticalco Is to prevent buckkng of Individual truss web and/or chord members only Adddtonal temporary and perrnananl tkacmg A11;Te 1. is aays requited for stabAOy and to prevent collapse with possible personal Injury and property domage.For general guidance regarding the 1 71 S -sC fabrication,storage,doir,*ry,erection and bracing of trusses and Truss systems,see ANSIITPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute.218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 ttru Met ins A 95610 �i _ I Job Truss ITRU, ipe Qty Ply LGI V. _S 2514 FL r R50499434 2514-FL C1 FbOT 3 1 Job Reference(optional) HMG, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MITek Industries,Inc. Mon May 0813:21:47 2017 Page 1 I D:migzTLjh7H 1 sSQCF V f nR06ztaVJ-BSxcwgxxAwLcx87 sMwznhUduteYpY7UQ3PWN8eziYZ2 0-1-8 I— 1"1'B Ii71 ?G-0 0-t4 0*8ri 8 1-1-8 Scala=1:23.3 1.5x4 II 4x6 II 3x4 II 3x4= 1,5x4 II 3x4= 3x4 II 4x6 II A B C DE F G H TI N M L K3x4= J I 1-5x4 II 46= 3x4= 46= 1.5x4 II 0 13-1-12 Oil 1 a 0 13.04 0. .8 Plate Offsets(X,Y)- IA:030.Edae1 IH:0-3-0 Edgel fK:0-1-8 Edael IL:0-1-8 Edoei LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (lac) I/deft Ltd PLATES GRIP TCLL 400 Plate Grip DOL 1.00 TC 0.28 Vert(LL) -0.07 L >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 100 BC 0.46 Vert(CT) -0.11 L-M >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(CT) -0.02 H n/a n/a BCDL 50 Code IRC2015/TP12014 Matrix-R Weight:59 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) A=709/0-1-8,H=709/0-1-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-B=632/0,B-C=-631/0,C-D=1709/0,D-E=-1709/0,E-F=170910,F-G=-631/0,G-H=-632/0 BOT CHORD L-M=0/1413,K-L=0/1709,J-K=0/1413 WEBS A-M=0/915,H-J=0/915,F-J=-887/0,C-M=887/0,F-K=0/416,C-L=0/416 NOTES- 1)Unbalanced floor live loads have been considered for this design 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A.H. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0.0 oc and fastened to each truss with 3-10d(0 131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. ,� RRLLL 8 i 1� y WASji 7� 51398 SIGNAL May 8,2017 WARNING-Vxlfy design paramol—and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.l e/0"01$BEFORE USE. Design valid for use onty wdh W olD connectors-This design Is based only upon parameters shown,and is for an mdwidual building component,not a truss system.Before use,the budding designer must verify five applicability of design parameters and property incorporate this design into the overall budomg design. Waiting indicated Is to prevent bucking at individual truss woo andlor chord members only.Additional temporary and permanent bracing TQI. is always required for stabdity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding Ilia 'a 1 S< fabrication,storage,delivery,erection and bracing of trusses and uuss systems,see ANSUTP11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane safety Information available from Truss Plato institute,218 N,Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 i I his 95810 I Job Truss Tri 1pe QI Pty LGI S 2514 FL R50499435 2514-FL C2 Floor 1 1 Job Reference o Uonal BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc, Mon May 0813:21:47 2017 Page 1 ID:migznjh7H i SSQCFV TnR08zlaVJ-BSxcwglorAwLo47sMwznhUdTReaZY81Q3PW NgezlYZ2 0-3-0 24-0 Scale=1:155 3x6 II 3x4 II 3x4= 1.5x4 II A B C D 3x4= E L _ 1.5x4= 0 1 5x4= K 3x6 = J I H G F 1.5x4 11 1.5x4 11 15x4 11 V Ili 30 = QOi 8-2-14 b 7-11-14 1 Plate Offsets(X,Y)-- IC:0-1-8.Edge1,f0:0-1-8 Edael [J:Edae 0-0-121 (K'0-1 8 0.0-12) [L:0-1-8 0-0-121 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. In (Ioc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TIC 0.37 Vert(LL) -0.05 H-1 >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.35 Velt(CT) -0.06 H-I >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(CT) -0 01 F n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:37 lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) A=426/0-2-14,F=426/0-3-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-B=383/0,B-C=-383/0,C-D=-601/0 BOT CHORD H-1=0/601,G-H=0/601,F-G=0/601 WEBS B-1=269/0,A-1=0/555,D-F=678/0,C-1=-281/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate atjoint(s)A. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6)CAUTION,Do not erect truss backwards. f o r0� 51398 ASSj�NALG May 8,2017 ®WARNING-VerNy design iaaramerere and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiToW conneclors.This design is based only upon parameters shown,and is for an individual building component,not a lass system.Before use,the building designer must verity the applicability of design parameters and property incorporate this design into the overall budding design Bracing indicated is to prevent buckling oRhdividual lnroa web and/or chord mombers only.AdditionaRemponvy end permanent bracing — — 1� - Is always required for stability and to prevent collapse with possible personal injury y and prop damages For general guidance regarding the „r'• e fabrication.storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N,Lee Street.Suite 312,Alexandria.VA 22314, Suite 109 C s Hei hts CA 95610 Job Truss Tru pa Qty Ply LGI h S 2514 FL R50499436 2514-FL D1 Floor 3 1 Job Reference o clonal BMC, EVERETT,WA 9820&3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 0813:21:48 2017 Page i ID:migzTLih7HlsSQCFVTnR06z1aVJ-af% 80yZwETSZli2weUODiAeplwnHbyai3Fwh5zIYZI 11����� 0-1-8 1-8 • I 941.0 1t 5-12 i 1-3-0 ; 0}IA Scale'=1:25.5 1.5x4 II 1.5x4= 3x6 II 3x4 II 3x4 = 3x4 II 3x4= 1 5x4 II 3x4= 1.5x4= A B C 0 Q E F G H o P ro 0 0 N M LIZ K J3x4= I 1.5x4 II 3x6 = 34= 1.5x4 II 3x4= 0.1118 6-9' 14-11 12 0.118 6-7.10 8.2.10 Plate Offsets(X,Y)— IE:0-1-8.Edge1 (J:0-1-8 Edge1 fO:0.1-8 0-0-121 IP:0-1.8 0-0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.33 Vert(LL) -0.05 I-J >999 480 MT20 185/148 TCDL 100 Lumber DOL 1.00 BC 0.28 Vert(CT) -0.08 I-J >999 360 BCLL 0 0 Rep Stress Incr YES WB 0.14 Horz(CT) 0.01 1 n/a n/a BCDL 5 0 Code IRC2015fTP12014 Matrix-R Weight:64 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) A=346/0-1-8,L=818/0-5-8,1=443/0-3-7 Max Grav A=395(LC 8),L=818(LC 1),1=446(LC 8) FORCES. (lb)-Max,Comp./Max.Ten.-All forces 250(1b)or less except when shown. TOP CHORD A-B=-346/0,B-C=34410,E-F=637/0,F-G=-637/0 BOT CHORD L-M=0/550,K-L=0/637,J-K=0/637,I-J=0/603 WEBS A-M=0/499,D-L=-274/0,C-L=-517/0,G-1=684/0,E-L=-689/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to Increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6)CAUTION,Do not erect truss backwards. V,V,BRfL 8 was ' 0 .0g 51398 cy� GIS'1'gii" �l�' AL ECG May 8,2017 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MI TEK REFERENCE PAGE Miff-7473 rev.1010312015 BEFORE USE. • Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the bullding designer must verity the appllcabllily of design parameters and properly incorporate this design into the overall duddmg design. dieting indicated is to prevent buckling of individual truss web and/or chord members Orly,Additional temporary and permanent bracing r1���e I$always required for stabdly and to prevent collapse with possible personal Injury and property damage. For general guKisnoe regarding the 1 1� fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSUTPit Quality Criteria,ose-89 and OCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N Lee Street.Suite 31Z Alexandria,VA 22314 Suite 109 a t his C I 1 � � � I I Job Truss JF /pe Qly Ply LGI i -S251 FFLR50499437 D3 oor 5 1 Job Reference.(optional BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 081321:50 2017 Page 1 ID:migzTLjh7H 1 SSQCFVrnR08ztaVJ-Xt dkZizqSfjA=R13WU17FuNrRSITsONklmvJYZ9 0-1-8 280 � 0- H� ,' 1 F � 1�B-1� 8 I� Scale=1:33 4 3x4= 3x4= 3x4 11 4x6= 3x4 = 3x6 FP— 3x6= A B C D E F G H I J K Xo rb U Eie 'A FE S RQ 0 O N M 3x4= 3x6 FP= 3x10= 3x6= 3x10= 3x6= 5-5& 24yr,4 5-" 14 11 14 Plate Offsets(X,Y)— fA.Edge,0-0-121.18.0-1-8 Edge] [C 0-1-8 Edoel [G 0-1-8 Edoel 10.0-1.8 Edoel [U:0.1-8 0-0-121 N'0-1 8 0.0.121 IW 0-1 8 0.0-121 fX 0-1 8 0-0 121 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 071 Vert(LL) -0 25 M-N >716 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 1 00 Vert(CT) -0 32 M-N >561 360 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(CT) 004 L n/a n/a BCDL 5.0 Code IRC2015rrP12014 Matnx-R Weight:84 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (lb/size) L=801/0-5-6,T=258/0-3-6,P=1148/0-3-8 Max Grav L=805(LC 7),T=333(LC 10),P=1148(LC 1) FORCES. (lb)-Max,Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-380/62,E-F=-2057/0,F-G=2057/0,G-1­1=202410,H-J=2024/0 BOT CHORD S-T=-62/380,R-S=-62/380,P-R=-62/380,O-P=0/1228,N-0=0/2057,M-N=0/2057, L-M=0/1269 WEBS B-T=429/70,C-P=-492/0,E-P=-1483/0,E-0=0/992,F-0=-337/0,J-L=-1440/0, J-M=0/857,H-M=-320/0,G-M=-294/128 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances c.,rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. �E"XL 44 J� Of WA SA, `7J� 51398 44 sSr�NAL ECG May 8,2017 WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1-7473 rev.1010312015 BEFORE USE. Design valid for use only with MITeke connectors This design is based only upon parameters shown,and is for an Individual budding component.not a truss system Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall p+� 's brnkhng oo ti sign.tin Indicated is to prevent buckling of individual truss web anaror cnord members only Ad nai deio temporary and permanent tracing truss systems,son ANSIITPII Quality Criteria,DSO-89 and SCSI Building Component 7777 Greenback Lane -- @ 9�RD -- ------ Is fabrics ion,slorago,delivery,erection and bracing of trusses and always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 9 t Safely Information available from Truss plate institute.218 N.Lee Street,Suite 312,Alemadna,VA 22314 SWte tog Citrus Fie;bnts CA 9 0 II �; k R I Job Truss Tri pe Qty Ply LGI 1 S 2514 FL 1 2514-FL D4 GABLE 1 1 Job Reference(optional) R50499438 BMC, EVERETT.WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 1321:51 2017 Pape 1 ID:mlgzTLih7HlsSQCFVrnRO6ziaVJ-7EB6m2_SD9r1QmRdbm2irKoCaFOGU UO_IUaIP7JYZ 0 8 0-W Scale=1:33.6 3x6 FP= 2x4 I I A B C D E F G H 1 J K L M AC. Z ZZ AB Y X W V U T S R Q P O N 3x6 = 3x6 FP= o-b-8 0- 2-5.8 44i-8 8S8 &8.8 10.541 12.5.8 14:2 T&68 1&5.8 20.5.4 0--8 2-0-0 2-0-0 2.0.0 2-0-0 2.OA 2-0-0 L2 2-0-0 2-0-0 1-it-12 0.4 0 Plate Offsets(X.Y)— fA:Edf1e 0.0-121 fM:0.1-8 Edael fZ:0.1 8 0.0-12] fAA:0.1-8 0.0-121 (AS:0 1-8 0 0-121 IAC:0.1 8 0-0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 40 0 Plate Grip DOL 1.00 TC 0.16 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.04 Vert(CT) n/a n/a 999 BCLL 0 0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 N n/a n/a BCDL 50 Code IRC2015/TPI2014 Matrix-R Weight:67 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. OTHERS 2x4 HF No 2(flat) REACTIONS. All bearings 20-2-4. (lb)- Max Grav All reactions 250 Ib or less at joint(s)Y,N,X,V,U,T,S,R,Q,P,O FORCES. (lb)-Max.Comp/Max.Ten -All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)T(uss to be fully sheathed from one face or securely braced against lateral movement(j e.diagonal web). 5)Gable studs spaced at 2-0-0 cc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 cc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 0 51398t�° S70NAL� May 8,2017 WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.1010312016 BEFORE USE. r, Design valid for use only with MITek®connectors.This design is based only upon parameters shown,and is for an individual tndfaing component,not a truss b system.Before use,the building designer must verify the applk;abdlly of design parameters and property incorporate this design mto the overall ��/ Wilding d:911.Bracing Yid"ed is to pravenl lnxklelg of ladiwduel buss.web.,Ku.uwd 111.0wa uidy.Addiii—i lumpmwy.mu yvnnmwul bracing iTe k' is aways required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the 9N9 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPI7 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 C —H I hl CA 10 _ i Job Truss Tr. ape Ll � LGI, PS 2514 FL2514-FL F1 R5049943FLR GIRDER 2 Job Reference Lopiional QMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MITek Industries,Inc. Mon May 0813:21:51 2017 Page 1 ID:migzTLjh7H i sSQCFVTnR06zlaVJ-?EB6m2_SDgr1 QmRdbm2jrKo8PFyhUxRO_1 UalPzIYZ_ 2.11.3 i Scale:1"=1' A 4x5 I I F B 3x4= C4x5 II 3x4= 3x4 = 1-14 M Plate onsets(x.Y)— tc:Ed9e a3-sl 8-1-14 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.43 Vert(LL) 0.00 D-E >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.27 Vert(CT) -0.00 D-E >999 360 BCLL 0.0 Rep Stress Incr NO WB 0,22 Horz(CT) 0.01 D n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:53 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No 1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr except end verticals. WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) E=1529/0-5-8,D=1855/0-11-14 FORCES. (lb)-Max Comp./Max.Ten.-All farces 250(lb)or less except when shown. TOP CHORD A-Ii-450/0,C-D=-783/0,A-B=-284/0,B-C=-304,0 BOT CHORD D-E=0/2979 WEBS 8-E=-2891/0,B-D=-2870/0 NOTES- 1)2-ply truss to be connected together with 10d(0 131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-9-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to Increase plate sizes to account for these factors. 4)Recommend 2x6 strongbacks,on edge,spaced at 10.0.0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) RRIjL Vert:D-E=10,A-F=-100,C-F=527 WAS 8A. Concentrated Loads(lb) J Of Vert:F=-1034 aQT �rA 51398 '� ��SjONALG May 8,2017 � &WAMING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design Is based only upon parameters shown,and is for an Individual building component,not a tress system Before use,the building designer must vent'the applicability of design parameters and property incorporate[his design into the overall budding design 9ra=g indicated is to prevent buckling of individual buss web and/or chord members only, Additional lomporery and pernumenl bracing rt ®�T is always required lot stability and to prevent collapse with possible pomoral injury and property damage. For general guidance regarding the 1`l,� 1 fabrication,storage,delivery,erection and brsong of trusses and truss systems,see ANSMII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N,Lee Street,Suite 312.Alexandria,VA 22314. Suite 109 Citrus CA 9 1 1 �I', �I Job Truss Tn ape 1QW Ply LGI. _S 2514 FL r R50499440 2514-FL F2 FLOOR GIRDER 1 2 Job Reference(opts BMC, EVERE-T,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 0813:21:52 2017 Page 1 ID:migzTLjh7H1 sSQCFV rnR06ziaVJ-TQkU_O?4_Tzul vOg9UZyNYLNKfEVDL49DhD7pszlYYz 2.84 i Scale=1:11 1 5x6= A 5x6= B1.5x4 II C ct (V 6x12 = G E H 1.5x4 II 1.5x4 II �01$ 2-1 LB 03 8 2-8.0 2 -0 I5 8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0 04 E-F >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.55 Vert(CT) -0.05 E-F >999 360 BCLL 0 0 Rep Stress Incr NO WB 0.39 Horz(CT) -0.00 D n/a n/a BCDL 5.0 Code IRC2015fTP12014 Matrix-P Weight:49lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 5-11-0 oc purlins, BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btf except end verticals. WEBS 2x4 HF No 2 BOT CHORD Rigid ceiling directly applied Or 10-0-0 oc bracing. REACTIONS. (lb/size) F=1648/0-5-6,D=2232/0-5-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-F=1199/0,C-D=-1199/0,A-B=-3065/0,B-C=-3065/0 WEBS A-E=0/3235,C-E=0/3235 NOTES- 1)2-ply truss to be connected together with 1Od(0.131"xW)nails as follows: Top chords connected as follows:2x4-1 row at 0-9-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniforin Loads(plf) Vert:D-F=-10,A-C=-100 Concentrated Loads(lb) ItRiL�B Vert:G=-1085 H=-1085 1=-1092 F WASx 0 51398 Q� �A �GISTE�� �sSjotvaL � May 8,2017 WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.1010312015 BEFORE USE..-- Design valid for use only with MiTek®connectors-This design is based only upon parameters*flown,and is for an individual bustling component,not . a truss system.Before use,the budding designer must venly the applicability of design parameters and property incorporate Ibis design into the overall --—building design.Bracing indicatod is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing.--- — s\A�Tef.� is ah l91vays required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the 1 iC fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSVTPll Quality Criteria,DSS-89 and SCSI Building Component 7777 Greenback Lane Safely information available from Truss Plato Institute,218 N.Lea Silver.Suite 31Z Alexandria,VA 22314- Suite 109 Cg H i hts A 5 10 � �, I I Job Truss TI ype Oty Ply LGI �S 2514 FL 2514-FL F3 FLOOR GIRDER 1 R50499441 Job Reference(o-p0onal) BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MTek industries,Inc. Mon May 08 13:2L53 IS 7 Page 1 I D:migzTLjh7H 1 sSOCFVrnRO6ziaVJ-xcltBk?Itm51f3bOiB4BwlIN32XPymvJRLzhMlzlYYy Scale=1:18 0 1,5x4 II 4x12= 1 5x4 II 1.50 II 4x12 = 15x4 II A K B L C D M E F u u N I H 3x10 = 3x10 = 4x8 = 4x8 = t 4.378 4." 1-3.0 438 Prate Offsets(X Y)— fH:0-3-8 0-1-81 f1:0-3-8 0-1-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (ioc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.87 Vert(LL) -0 13 H-1 >870 480 MT20 185/148 TCDL 10-0 Lumber DOL 1.00 BC 0.77 Vert(CT) -0.18 H-1 >625 360 BCLL 0.0 Rep Stress Incr NO WB 055 Horz(CT) 0.03 G n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-RH Weight:92 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.18Btr TOP CHORD SIFUctnral.vood sheathing directly applied or 2-11-6 oc purlins, BOT CHORD 2x6 OF SS except end vedicals. WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) G=3789/0-4-8,J=3714/0-5-8 Max Grant G=3789(LC 1),J=3718(LC 3) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-J=-475/0,F-G-990/0,B-C=9514/0,C-D=-9514/0,D-E=9514/0 BOT CHORD I-J=0/7419,H-1=0/9514,G-H=0/6325 WEBS E-G=-6819/0,B-J=-7998/0,E-H=0/3557,B-1=0/2264,C-1=-1075/0,0-H=-1510/0 NOTES- 1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-7-0 oc. Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-7-0 oc,Except member H-E 2x4-1 row at 0-9-0 oc,member I-B 2x4-1 row at 0-9-0 oc ,member I-C 2x4-1 row at 0-9-0 oc,member H-D 2x4-1 row at 0-9-0 oc. 2)Ail loads are considered equally applied to all plies,except 4 noted as front(F)or back(8)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)Unbalanced floor live loads have been considered for this design. 4)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 0 OWAS NI,t J Uniform Loads(plo C �' Vert:G-J=10,A-F=-100 Concentrated Loads(lb) Vert:F=-891 E=-852 D=1461 K=-1461 L=-1461 M=-326 51398 TE SIQNALEt^� May 8,2017 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MI TEK REFERENCE PAGE MII7473 rev.1010312015 BEFORE USE.Design valid for use only with MITek®connectors This design is based only upon parameters shown,and is for an individual building component,not a tress system.Bofors use,the budd desl r must veri the a lkablli ofde n aremeters and o e arc ato this desi n Imo the overall101 m9 N PP N .. P_ P!P M orpor gbu&Nng design Bracing indicated is to preventbuckling of Iridivlduai truss web andlor ciwto nrombers ordy.Additional emporary and permanent bracingis always required for stability and to prevent collapse with possible personal IMury and property damage For general guidance regarding the fabrication.storage,delivery,erection and bracing of trusses and truss systems,see ANSVTPit Oualiry Criteria,OS8.89 and SCSI Building Component 7777 Greenback Lane Safety Infomellon available from Truss Plate Institute.218 N.Lee Street.Suite 312.Aloxandda,VA 22374. Suits re CA He 8 0 �i co p D g ao r �W cam D -4 ,p ov r W m D � z °c�)�d3GS�cooyp° dnv z°: �Q � rX m d— sy D No 0 cW m nDmagmON 0 ID a D o C O -0 o O m M n 3 cl) C)N� �7 m wF o o Z -► s O ID aS?Dp0 �� 0 g•cWcn 5 ° `tea O � o� � (D '0' mS a o Z W O 3 Q n T. W 3 Cl (-y _a 4 fD L ra 9(D -Or N 7� N 0�- O g�N CrDr= v �. 0/ ct 7 5.W N N a� 3 W 7 D n� m cn Wr2Way 9c n CD *°' oa3 ToN cVWW �� w (DO�� S S 0 O ?W S Q S (n CD _a Ol 0 a D] O w 20 _ om omco ° m m� D mW oqo _;o ° ° mm O W ocnmOU• mocoi °: -1vW d 0c3 WO W "- (u 3W W - ;a cn tD n n Q 7 c o O@`� O N N m 7 (D^•a S N O°1 a 0 n7 I W O(D n 01 N (D 7 l O l n.Q Z a a W ° �o2 °1a 7o fD avo 3 3 � 3 R ° o�.�io Z Z (° 0 o O ._.C7 � Q N �, l fA.50 N 7 (D n W (°p N CD.8 N' N (n N C S cn a,�.. —1-1 a ° On W !D W !� 5 .CD o O m 7' W ° S y ° a 7 O 5'0 N j,n o N CD (° rn O a 0 C N N (D @ N y y Z O. C C •`2 3 O N fD O ((DD W n 6 o a W m c (D x o ' m "7 O O N S O c 3 '•G CO0 . X U) n � c= m p TOP CHORD � 8•6 CO 5) &;u 9 O 30 Oz ca (O 7 (D C (D (O m 0 03 G m Z-i V CD (D CL (n � m ° r-Z m m rn � � (D wm - m ° �� 5N w� m� zZ W O 00 CD � mv c77D(o CD Co m �W m N �e=i1 (D C 2 N N D y cn y D V O W2 7 = 7 N N w N a m Ill D O O N a 0 -4 Zo3Do F. U voZD' M v a oo m(n cAcl) �f p n m m cl) y o v V w -< m 'o � y F 00 m O-�i o' rh < - c 0 3 N o zm N %c1 CD c M VS -4. , 9 (D N Z DN < Z m O �fD Nm N NN 7 yN 3 * U7 a 7 m m TOP CHORD N O (O W J � N ? W N � � W W J W N A W DO H 3� v (C n (� o co r �� ° (� cC va C ZN m m .N.. -a p O o �o c N (� 7• �O 00 9 0 NG.V nz U3 F1 C.D (n0 ° a<_ �<° � 7 m� �� �°' 3 �°: 3a� �� nil my Mao c °tio mm n�dd2 oia � C �z m �pO m °p m m3 'g =(gym °1M min ty 7m ?'� owm 3 rs6 �� 15 o mn319 7 0 ao ay m m� o °tea m 0(Dm 3 (D nacv ° o fQ N n W fC. tq fl. 7 7 CD O C.N N N N N O Q N -.X (D a N 5 O' 3 m , R A -C-i fNil Ol G N 0 pc (Ti...$ (7(pp �7 o n� '� H ° a ( a 'm_m n,�m m� m 3c �3 y �yp�a �.,D °m m5• p T N ?Q 7 i' O G 7 m 7 m N R C y N N N 7 O N 3 o W N 1Q O d o C P l° X M N •"O - .°.. N (D 3 3 O no)-�_° (g y O N m(D tD Q 7 R N N n D) Q 6 0 7 o m' m a u, a d 7.o a m a m o 2 S o D v �.3 -� CD O mmmm y � .- 7 o$c °m Dci 3 02 a7 07 f ccm m B� 70 °o0. c,,< (D � mN m aN (D c ay2 o° dN n^!`Z� m $c� H 5.m 89 .O• 5.v -� O �.0 m? mo"h _ my 7 rom oO 3d nv� n o n �� mTni ?$ am N° a(p � � f0 m-CD D C '3 Ol .N.R N.nl O -0 M Q� L. O N O.7 0 N 2 D 7 G n u; d c °cD m m3 �_ m m m m� m� m f�.m m� 3 a� �Qm nz.m a andaO $mc W N O N 3 N R ?fl. N fn 7 DI ,n.N° �D N ° .= D N O •G O a nl N N O C.tC D3 p 7 f J 3 N. c@ °i (i (D 1°n 7 -f7n p•1 m M C 7 W p.C V N .<7 n R 41 N n. -8 O V7 a <IC N O Z C `l Vl 7 < ET Q (] tC A•f n V (D N y C° (D O M 7 O'° In= nl .yn Vryry _ N (D (a N o ? a S o 10 - 7 nl R• m ui = J W 7 R N 3° NO 7 c� O a fD Q 7' v °:n W7 N7 yO 0.3 �� �°:A O m Q O Ju OdW a n _ �y N N o y 7 Q .�Z' z• (D D O ry' /}�1 d 7 c 7 R �� ° R C y 7 y 3 N A 61 C)N 3 0 `G 7' < N N n 00 7 - N n fn- C �. 00 7m7 o o l(//��'m a 7 -�.-• � c m o. W 7 7 m m m T 3 ° 7 A 2 .C. fD (D N N N IC 3 7 7 N N N m (D tC y Ma � N $. M' °p Q. m o. � vi m m a m n ° ° 3 T CWi O l< 3 3� 3 M CD zN 0jj i J"� ,_ ip . ■ I n0-00-00 cl n N \ W O C �Q LAI p m O rrr fp f 3 � a o _ rt J 6-00-00 415-00-00 Y� C�n �p II Ob zny� " 7 - cn O �pOr� o �y e C_'O ' Om Coayere l Dearer 111 Oir11Mr LGI NOMES )ob Number Sh..l TLL c BMCI+20035Nhrmue NE l E,e N'AI9ffi01 Job Name/Motlel 2S14-A RF GL DealrAer OAN C, p e.e �gyy, TRUSS LAYOUT QrfCoa+�li�BuilNatiM:am.v.»w.&aldWehDMC.oan.Atltlr�e.: Dale 5/0/2017 �• I I I Job Tr—uss T y p e y JMES 2251+A RF 2514-A Al Common Supported Gable 1 1 Ilob Reference o ionab BMC.EVERETT,WA 98205.3212 8.000 s Jul 115201161kTakindusWes Inc. Mon Mayy 0815:1430 2017 Paagqe 1 �t18g ID:migzTLjh7H1sSQCFVrnRO6ziaVJ4 w698ygt_DEkReKNDzpGIRgCCIbCBkGNkjgzlVSt 8-3-0 1 16- -0 17-6-0 0-0 8.3-0 8-3-0 I 1-0-6 I Scale:3/8"=1' 4x5= F 5.00 12 E G S T U V D H r C I T T B J ® K �o 3x4= R Q P O N M L 3x4= 18-9-0 16-6-0 16-6-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 25-0 Plate Grip DOL 1.15 TC 0,11 Vert(LL) 0-00 J n/r 180 MT20 185/148 (Roof Snow--25.00).0 Lumber DOL 1.15 BC 0.06 Vert(CT) 000 K n/r 180 BCDL Rep Stress Incr YES WB 0.03 Horz(CT) 0-00 J n/a n/a BCLL .0 BCDL 10.0 Code IRC2015/TPI2014 (Matrix) Weight:57 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HIP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabillzer Installation guide. REACTIONS. (lb/size) B=162/16-6-0 (min.0-2-8),J=162/1646-0 (min,0-2-8),0=159/16-6-0 (min.0-2-8),P=169116-6.0 (min.0-2-8).0=164/16-6-0 (min.0-2-8) R=182/16-6-0 (min.0-2-8),N=169/16-6-0 (min.0-2-8),M=164/16-6-0 (min.0-2-8),L=182116.E-0 (min.0-2-8) Max Horz B=-46(LC 13) Max UpliftB=-22(LC 8),J=-24(LC 9),P=-25(LC 12),Q=-25(LC 12),R=-23(LC 12),N=-24(LC 13),M=-25(LC 13),L=-23(LC 13) Max GravB=178(LC 18),J=178(LC 18),0=159(LC 1),P=213(LC 19),Q=170(LC 19),R=182(LC 1),N=213(LC 20),M=170(LC 20),L=182(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/41,B-C=-56/35,C-D=-39/39,D-S=-35/60,S-T=-16/61,E-T=-16/64,E-F=-43/106,F-G=-43/106,G-U=-16/64,U-V=-16/61,H-V=-35/60, H-1=-35/35,I-J=-40/19,J-K=0/41 BOT CHORD B-R=-7/53,Q-R=-7/53,P-Q=-7/53,O-P=-7/53,N-0=-7/53,M-N=-7/53,L-M=-7/53,J-L=-7/53 WEBS F-0=-120/6,E-P=-173/92,D-Q=-131/57,C-R=-137/78,G-N=-173/92,H-M=-131/57,I-L=-137/78 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-3-0,Exterior(2)2-3-0 to 5-3-0,Corner(3) 5-3-0 to 8-3-0,Exterior(2)11-3-0 to 14-3-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11)*This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 22 lb uplift at joint B,24 lb uplift at joint J,25 lb uplift at joint P,25 lb uplift at joint Q,23 lb uplift at joint R,24 lb uplift at joint N,25 lb uplift at joint M and 23 lb uplift at joint L 13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. ' I 1 iL I o toss toss ype y XES2514-ARF 2514-A A2 Common 1 1 Job Reference(opliona0 9MC.E RETT,WA 90205-3212 8.000 a Adis 2016 MiTak Industries.Inc. Mon May 08 IS:14 31 2017 Page 1 9-0 ID:mlgzTLjh7H1sSQCFVTnR06z1aVJ-YAUUNXySeHL4MbCWxWU2oz_sTcODKe?tggwZHFGzlv6s 4-7 3 8-3-0 11-10-12 16-6-0 �'t"7-6-0, 1-0-0 4-7-4 3-7-12 3-7-12 4-7-4 1-0-0 Scale:3/8"=1' 45= D 5.00 12 2x4 j K L M 2x4 C E - t N B F GR H 3x6= 3x6= 3x10= 18-9-0 18-9-0 83-0 164-0 8-3.0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.24 Vert(LL) -0.09 F-H >999 240 MT20 185/148 (Roof Snow-25.0) Lumber DOL 1.15 BC 0.55 Vert(CT) -0.19 F-H >999 180 BCDL .0 0 BCLL Rep Stress Incr YES WB 0.12 Horz(CT) 0.03 F n/a n/a .0 'BCDL 10.0 Code IRC20151TPI2014 (Matrix) Weight:56 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 4-9-6 cc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) B=752/0-5-8 (min.0-1-8),F=752/0-5-8 (min.0-1-8) Max Horz B=-46(LC 13) Max UpliftB=-49(LC 12),F=-49(LC 13) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/42,B-1=-1234/107,C-1=-1197/120,C-J=-939/71,J-K=-927/73,D-K=-891/82,D-L=-891/82,L-M=-927/73,E-M=-939/71;E-N=-1197/120, F-N=-1234/107,F-G=0/42 BOT CHORD B-H=-70/1093,F-H=-53/1093 WEBS D-H=0/449,E-H=-353/107,C-H=-353/107 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 5-3-0,Exterior(2) 5-3-0 to 8-3-0,Interior(1)11-3-0 to 14-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 49 lb uplift at joint B and 49 lb uplift at joint F. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 1 .� - .� x Job Truss toss ype Qty plyOME$2514ARF 2514-A B1 GABLE 1 1 Job Referenm(optionaQ BM ,EVER ,WA 9620"212 5.000 s Jul 1 2016 MtTck Induatliea Inc, Mon May 06 15:14i31 2017 Po 1 ��aa,9-0 ID:migzTLjh7H1sSOCFVTnR0WaVJ-YAUUNXySeHL4MbCS/*wU2oz JvcPgKeopii&7 GzIVBs 0-0-D, 11-9-0 15 3 0 23.6.0 a r1 0 0 11-9-0 3 8-0 8-3-0 1-0-0 Scale=1:44.8 45= I 412= 5.00 F12 G K V W ry1 E L 0 J, C H U X _ B R F N BI O (o Q 31�4= E-5-8 T S 3x6 3x4 P 3x6= = 18-9-0 18-9-0 , 15-3-0 , 23-6-0 1630 8-3-0 Plate Offsets(XX_,y)— 1M:0-5 12 Edge] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.79 Vert(LL) -0.12 N-P >999 240 MT20 185/148 (Roof Snow 2 7.0 Lumber DOL 1.15 BC 0.59 Vert(CT) -0.25 N-P >806 180 TCDL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.03 N nla n/a BCD- 0.0 * Code IRC2015ITPI2014 (Matrix) Weight:95 lb FT=10% CD 10.0 LUMBER- BRACING- TOP CHORD 2x4 HF No.2*Except* TOP CHORD Structural wood sheathing directly applied or 4-1-7 oc purlins. T2:2x6 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. BOT CHORD 2x4 HF No.2 JOINTS 1 Brace at Jt(s):J,H WEBS 2x4 HF No.2 Mffek recommends that Stabilizers and required cross OTHERS 2x4 HF No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation aulde. REACTIONS. (lb/size) B=252/7-5-8 (min.0-2-3),5=-210/7-5-8 (min.0-2-3).T=314/7-5-8 (min.0-2-3).N=78110-S-8(min.0-1-8),R=96017-5-8 (min.0-2-3) Max Horc B=64(LC 12) Max UpliftB=-11(LC 12),S=-210(LC 1),T=-39(LC 12),N=-58(LC 13) Max Grav B=267(LC 19),T=314(LC 1),N=781(LC 1),R=960(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/41,B-U=-210/0,C-U=-159/8,C-D=-193/28,D-E=-188/44,E-V=-198/65,G-V=-163/68,G-1=-176/90,1-K=-175/92,K-W=-173/72, M-W=-177/68,M-X=-1078/76,N-X=-1168/52,N-0=0142,F-R=-1019/131,F-H=-959/121,H-J=-947/116,J-L=-921/110,L-M=-884/97 BOT CHORD B-T=0/161,S-T=0/161,R-S=0/161,Q-R=0/983,P-Q=0/983,N-P=0/989 WEBS I-J=-70/17,G-H=-84/38,E-F=-162/57,D-S=-115/38,C-T=-199/75,K-L=-96136,M-P=0/360 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 8-9-0,Exterior(2) 8-9-0 to 11-9-0,Interior(1)14-9-0 to 21-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 11 lb uplift at joint B,210 lb uplift at joint S.39 lb uplift at joint T and 58 lb uplift at joint N. 12)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7-u-s-S-1 ype y y S 2514 ARF 2514-A B2 Girder 1 3 lJob Reterence1optloo BMC.EVERETT.WA 987.053212 8,000 s Jul 15 2016 Mii Industries,Inc. Mon May 0815 1414:33 2017 Page 1 18-9-0 18_9_0 ID:migzTLjh7H 1 sSQCF VTnR06zlaVJ-UZbFnDjAvbobvMv2LXM0387P4koQ_5YEcOK6R19�q 4 1-11 7-2-12 1 11-9.0 1634 19-4 5 23-6-0 I 4 1-11 3-1-1 4-6-4 4-64 3-1-1 4-1-11 Scale=1:40.6 45= D 5.00 12 r 6x8 6x8 C M N E 3x6 3x6 B F A G 11 7 o �o P L Q R S T J U V I W H X Y O K 4x6= 46= 3x10 II 12x12= 8x12= 12x12= 3x10 II 18-9-0 18-9-0 18-9-0 Qr6 12 2 6-12 4 1-11 , 7-2-12 1179-0 16 3� , 18rM5 22$12 23 8 0 3 1-1 4-6-4 4 6� 3 1- 3.2 7 O'-111 Plate Offsets{X Y)— rJ:041.0.0 4.81 LOADTCLL (psf) 25 0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP (Roof Snow=25.0 Plate Grip DOL 1.15 TC 0.42 Vert(LL) -0.10 I-J >999 240 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.62 Vert(CT) -0.17 W >999 180 BCLL 0.0 Rep Stress Incr NO WB 060 Horz(CT) 0.02 G n/a i BCDL 0 0 Code IRC2015ITPI2014 (Matrix) Weight:340 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 5-11-0 oc purlins. BOT CHORD 2x6 OF SS BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 HF No.2 REACTIONS. (Ib/size) A=1702/0-5-8 (min.0-1-8),G=6544/0-5-8 (min.0-2-5).K=13263/0-5-8 (min.0-4-11) Max HorzA=-58(LC 28) Max UpliftA=-92(LC 10),G=-350(LC 11),K=-668(LC 10) Max GravA=1745(LC 16),G=6566(LC 17).K=13263(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=-68/1146,B-C=-213/4463,C-M=-3399/210,D-M=-3387/223,D-N=-3357/213,E-N=-3427/200,E-F=-8639/481,F-G=-11670/629 BOT CHORD A-0=-1009/127,O-P=-1009/127,L-P=-1009/127,L-Q=-1009/127,Q-R=-1009/127,K-R=-1009/127,K-S=-4084/273,S-T=-4084/273,J-T=-4084/273 ,J-U=-377/7963,U-V=-377/7963,I-V=-377/7963,I-W=-549/10700,H-W=-549/10700,H-X=-549/10700,X-Y=-549/10700,G-Y=-549/10700 WEBS D-J=-103/2310,E-J=-5815/353,E-1=-220/4900,F-1=-3134/196,F-H=-94/2547,C-J=-424/8570,C-K=-7934/426,B-K=-3615/220,B-L=-105/2758 NOTES- 1)Special connection required to distribute bottom chord loads equally between all plies. 2)3-ply truss to be connected together with 1 Od(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-7-0 oc. Bottom chords connected as follows:2x6-3 rows staggered at 04-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc,Except member E-1 2x4-2 rows staggered at 04-0 oc. 3)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S) section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 4)Wind:ASCE 7-10;Vult=11 Omph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B; enclosed;MWFRS(envelope)automatic zone;cantilever left and right exposed;end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 5)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 6)Unbalanced snow loads have been considered for this design. 7)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)*This truss has been designed for a live load of 21 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 92 lb uplift at joint A,350 lb uplift at joint G and 668 lb uplift at joint K. 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)Hanger(s)or other connection devices)shall be provided sufficient to support concentrated load(s)1637 lb down and 86 lb up at 0-6-12,1630 lb down and 93 lb up at 2-6-12,1630 lb down and 93 lb up at 4-6-12,1630 lb down and 93 lb up at 6-6-12,1630 lb down and 93 lb up at 8-6-12,1630 lb down and 93 lb up at 10-6-12,1630 lb down and 93 lb up at 12-6-12,1630 lb down and 93 lb up at 14-6-12,1630 lb down and 93 lb up at 16-6-12,1630 lb down and 93 lb up at 18-6-12,and 1630 lb down and 93 lb up at 20-6-12,and 1633 lb down and 90 lb up at 22-6-12 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 1' I Truss ru55Type Qty - �AAE3251 RF r t 2514-A C1 Common Supported Gable 1 1 Job Reference�o t�Iona BMC.EVERETT,WA 98205.3212 8.000 s Ju115 2016 MITek Industries,Ina Mon May 08 15:14:35 2017 Papa 1 ID:migzTLjh7H1 sSQCFVTnRO6ziaVJ•Rxj?Cu?1.19WgDWHAtnZ?zp8YsDumG000?YSV0PlzIV8o 20•0-0 20-M 4 0�b Scale=1:73.7 5.00 F12 45= L M 3x4 K J N 3x4 H O giWE1 SI G P Q F 14R E 8 g e S p 6 7 8 T AO 6T1 3 5 ST1J AP 3 2 AB VW 0 3x4= AN AM AL AK AJ Al AH AG AF AE AD AC AB AA Z Y X 3x4= 5x6= 18-9-0 _ 40-0-0 � AD-00 Plate Offsets(X_,Y)- [P:0-0-0,0 0 01.fAF:O 3-0.0.3.01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL) -0.00 V n/r 180 MT20 185/148 (Roof Snow=2 TCDL 7•0.0 Lumber DOL 1.15 BC 0.07 Vert(CT) 0.00 W n/r 180 Rep Stress Incr YES WB 0.22 Horz(CT) 0.01 V n/a n/a BCLL 0.0 " Code IRC2015/TP12014 (Matrix) Weight:198 Ib FT=10% BCDL 10.0 LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 WEBS 1 Row at midpt L-AF MITek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) V=216/40-0-0 (min.0-3-12),AF=160/40-0-0 (min.0-3-12),AG=168/40-0-0 (min.0-3-12),AH=168/404)-0 (min.0-3-12),AI=168/40-0-0 (min.0-3-12),AJ=169/40-0-0 (min.0-3-12),AK=164/40-0-0 (min.0-3-12),AL=185/40-0-0 (min.0-3-12),AM=101/40-0-0 (min.0-3-12), AN=326/40-0-0 (min.0-3-12),AE=168/40-0-0 (min.0-3-12),AD=168/40.0-0 (min.0-3-12),AC=168/40-0-0 (min.0-3-12),AB=169/40-0-0 (min.0-3-12),AA=164/40-0-0 (min.0-3-12),Z=185/40-0-0 (min.0-3-12),Y=101/40-0-0 (min.0-3-12),X=326/40-0-0 (min.0-3-12), B=216/40-0-0 (min.0-3-12) Max Horz B=-105(LC 13) Max UpliftV=-7(LC 9),AG=-20(LC 12),AH=-26(LC 12),A1=-24(LC 12),AJ=-24(LC 12),AK=-24(LC 12),AL=-26(LC 12),AM=-16(LC 12).AN=45(LC 12),AE=-18(LC 13),AD=-27(LC 13),AC=-24(LC 13),AB=-24(LC 13),AA=-24(LC 13).Z=-26(LC 13),Y=-16(LC 13),X=-45(LC 13), B=-6(LC 13) Max GravV=216(LC 20),AF=169(LC 25),AG=246(LC 19),AH=243(LC 19),AI=214(LC 19),AJ=169(LC 1),AK=164(LC 19),AL=185(LC 1), AM=101(LC 19),AN=326(LC 1),AE=246(LC 20),AD=243(LC 20),AC=214(LC 20),AB=169(LC 1),AA=164(LC 20),Z=185(LC 1), Y=101(LC 20),X=326(LC 1),B=216(LC 19) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/41,B-AO=-118/38,C-AO=-108/67,C-D=-86/56,D-E=-64/65,E-F=-53/80,F-G=-39/94,G-H=-38/107, H-1=-29/110,I-J=-48/136,J-K=-58/174,K-L=-66/214,L-M=-66/214,M-N=-58/174,N-O=-48/136, O-P=-29/110,P-Q=-38/107,Q-R=-35/82,R-S=-36/55,S-T=-33/29,T-U=-55/14,U-AP=-67/41,V-AP=-87/21, V-W=0/41 BOT CHORD B-AN=-25/112,AM-AN=-25/112,AL-AM=-25/112,AK-AL=-25/112,AJ-AK=-25/112,AI-AJ=-25/112, AH-AI=-25/112,AG-AH=-25/112,AF-AG=-25/112,AE-AF=-25/112,AD-AE=-25/112,AC-AD=-25/112, AB-AC=-25/112,AA-AB=-25/112,Z-AA=-25/112,Y-Z=-25/112,X-Y=-25/112,V-X=-25/112 WEBS L-AF=-129/0,K-AG=-206/88,J-AH=-203/80,I-AI=-174/52,G-AJ=-128/56,F-AK=-126/53,E-AL=-138/61, D-AM=-86/35,C-AN=-230/123,M-AE=-206/88,N-AD=-203/80,O-AC=-174/52,Q-AB=-128/56, R-AA=-126/53,S-Z=-138/61,T-Y=-86/35,U-X=-230/123 NOTES- ' 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 3-0-0,Exterior(2)3-0-0 to 16-0-0.Corner(3) 16-0-0 to 20-0-0,Exterior(2)24-0-0 to 37-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as perANS1/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. &tiniue�sbn F�aa0aen designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 0 NSS fuss I ype y MES Ply — J 514•ARF 5 f } 1 2514-A C1 Common Supported Gable 1 1 Job Reference(optional) RETT.wA 9820532t2 8.000 s Jul 152016 M Tek Industries,Inc. Mon May 08 15:14;35 2017 Pape 2 ID migzTLJh7H1sSQCFVTnR06zlaVJ-Rxj?Cu?z7WsWgDWHAmZ?zp8YSDUmGOOO?Y5VP1zI%o NOTES- 11)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 7 lb uplift at joint V,20 lb uplift at joint AG,26 lb uplift at joint AH,24 lb uplift at joint Al,24 lb uplift at joint AJ,24 lb uplift at joint AK,26 lb uplift at joint AL,16 lb uplift at joint AM,45 lb uplift at joint AN,16 lb uplift at joint AE,27 lb uplift at joint AD,24 lb uplift at joint AC,24 lb uplift at joint AB,24 lb uplift at joint AA,26 lb uplift at joint Z,16 lb uplift at joint Y,45 lb uplift at joint X and 6 lb uplift at joint B. 13)This truss is designed in accordance with the 2015 Intemational Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIITPI 1. y I s otruss nJ55Type Qty Ply 6MES2514-ARF 2514-A C2 Common 5 1 Job Referenoe jo�tional)_ BMC,EVERETT.WA 98 12 5.000 s Jul 15 2018 MiTek Industries,Inc. Mon M�a�y08 15.1436 2017 Page 1 1 ID migzTLjh7H1sSQCFVTnRO6zlaVJ-v7HNQEObTq_NSM5UJU4EVOhVV d4b9mYEC1a }{zIVBn -,1w 7-1-3 13-9-4 20-0.0 28 2-12 32-10-13 40-0-0 � 0 0 7--1-3 t1 8 0 6-2-12 8-2-12 I G." 7-1-3 Scale=1:72.8 5.00 12 4x6= E 5x8 N Q 5x8 D F 2x4�� 2x4 i C W3 IAr3 G M P A B 1 HI I� 45= L Q R K S T J 45= 3x4= 5x8= 3x4= 18-9-0 18-9-0 10-3.14 20-0-0 29-8-2 40-0-0 10.3.14 941-2 9-8-2 1 14 Plate Offsets_(X Y J0:0-0-0._4 [F:0.4 0.0-3 41 jK:0-4-0�,00-3 0] LOADING(psf) SPACING-SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL(Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.96 Vert(LL) -0.36 J-K >999 240 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.73 Vert(CT) -0.63 J-K >756 180 BCLL 0.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.16 H n/a n/a BCDL 10.0 Code IRC2015/TPI2014 (Matrix) Weight:161 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 WEBS 1 Row at midpt F-K,D-K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance REACTIONS. (lb/size) H=1739/0-5-8 (min.0-1-14),B=1739/0-5-8 (min.0-1-14) with Stabilizer Installation guide. Max Horz B=-105(LC 13) Max UpliftH=-93(LC 13),B=-93(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/42,B-M=-3564/172,C-M=-3490/193,C-D=-3209/166,D-N=-2242/177,E-N=-2165/195,E-0=-2165/195,F-0=-2242/177,F-G=-3209/166, G-P=-3490/193,H-P=-3564/172,H-1=0/42 BOT CHORD B-L=-206/3199,L-Q=-94/2587,Q-R=-94/2587,K-R=-94/2587,K-S=-49/2587,S-T=-49/2587,J-T=-49/2587,H-J=-104/3199 WEBS F-K=-931/155,E-K=-5/1260,F-J=0/580,G-J=-422/161,C-L=-422/161,D-K=-932/155,D-L=0/580 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 3-0-0,Interior(1)3-0-0 to 16-0-0,Exterior(2) 16-0-0 to 20-0-0,Interior(1)24-0-0 to 37-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.0psf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 93 lb uplift at joint H and 93 lb uplift at joint B. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Job Truss FI,-U_S__S- Type y y 2514-A RF 2514,A C3 n 12 1 L*Refei �bnaU BMC,EVERM.WA 982 212 8.000 a Ju135 20�16 AATa'k Indua6las,Inc. Man May 08 15:14,37 2017 Pagoo 1 1 I D:m igzT Ljh 7H 1 sSQCFVTnR06zIaVJ-NKnnda 1 DD76E41MggHBbT2EElq 1 Q1kl3hSWJJ;y8m 1 13-" 6-2-12 26.2-2 32107-1-3 A13 I 39-7 61-0 7-1-3 .8.0 6-2-12 5-11.9 Scale=1:72.2 5.00 12 4x6= E 5x8 M = N 5x8 D F 2x4 2x4 C W3 G O L A 8 1 H 9 Io 4x5= K P Q J R S I 5x6= 3x4= 5x8= 3x4= 18-9-0 18-9-0 10-3-14 20-0-0 29-8-2 39-7.6 10.3-14 9 8 z 9-8-2 9.11.4 Plate Oflsels(X.Y)— 10:0-4-0,0-3-41 tF:0.4-0.0-3.41,f,I:04-0.0.3.01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 25.0 7.0 Plate Grip DOL 1.15 TC 0.95 Vert(LL) -0.35 J-K >999 240 MT20 185/148 (Roof Snow--25.0) Lumber DOL 1.15 BC 0.73 Vert(CT) -0.62 J-K >765 180 TCDL .0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.16 H n/a n/a BOLL 0.0 'BC L 10.0 Code IRC2015/TPI2014 (Matra) Weight:160 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 WEBS 1 Row at midpt F-J,D-J WEDGE MiTek recommends that Stabilizers and required cross Right:2x4 HF No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) B=1731/0-5-8 (min.0-1-14),H=1650/Mechanical Max Horz B=109(LC 16) Max UpliftB=-93(LC 12),H=-73(LC 13) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/42,B-L=-3544/175,C-L=-3470/196,C-D=-3189/169,D-M=-2221/180,E-M=-2145/198,E-N=-2145/198,F-N=-2222/185,F-G=-3149/181, G-0=-3377/210,H-0=-3464/199 BOT CHORD B-K=-211/3181,K-P=-99/2569,P-Q=-99/2569,J-Q=-99/2569,J-R=-69/2551,R-S=-69/2551,I-S=-69/2551,H-1=-137/3109 WEBS E-J=-7/1245,F-J=-909/156,F-1=0/544,G-1=-375/158,D-J=-926/155,D-K=0/581,C-K=-422/161 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-11-9,Iriterior(1)2-11-9 to 16-0-7,Exterior(2) 16-0-7 to 20-0-0,Interior(1)23-11-9 to 35-7-1 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Refer to girder(s)for truss to truss connections. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 93 lb uplift at joint B and 73 lb uplift at joint H. 10)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Job TC4 ss russ- ype y PrY-- , ES 2514-A R 2514-A GABLE 1 1 Job Reference(optional) BMC.EVERETT,WA 98205-3212 8.000 s Jul 15 2018 MfTek Indusff us,Inc. Mom 15. 438 2017 PasVe 1 1ID:migzTL)h7H1sSQCFVrnRO6ziaVJ-rM$rw2r REShgFsrv7ibRMa01n7rhWJ9?Mgg8 2D-M 39-7-6 0 2D-0.0 19-7-8 Scale=1:73.2 5.00 12 45= L M 3x4 K J N 3x4 H 0 G P Q F R E 8 S p 7 T 4 5sle 5 STU AD 2 AN 6T1 3 3 V AB o a{ [co dd o 3x4= AM AL AK AJ Al AH AG AF AE AD AC AB AA Z Y X W 3x4= 5x6- 18-9-0 39-7-6 39-7.6 Plate Offsets(X.Y)-- [AE:0-3-0 0-3-0)_ LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL) -0.00 A n/r 180 MT20 185/148 (Roof Snow=25 0.0).0 orz(CT)Lumber DOL 1.15 BC 0.07 Vert(CT) 0.00 A n/r 180 BCDL Rep Stress Incr YES WB 0.22 H 0.01 V n/a n/a BCLL .0 ' Code IRC2015/TP12014 BCDL 10.0 (Matrix) Weight:196 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No-1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No-2 WEBS 1 Row at midpt L-AE MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) V=129/39-7-6 (min.0-3-10).AE=160/39-7-6 (min.0-3-10),AF=168/39-7-6 (min.0-3-10).AG=168/39-7-6 (min.0-3-10),AH=168139-7-6 (min.0-3-10),AI=169/39-7-6 (min.0-3-10),AJ=164/39-7-6 (min.0-3-10),AK=185/39-7-6 (min.0-3-10).AL=101/39-7-6 (min.0-3-10). AM=326/39-7-6 (min.0-3-10),AD=168/39-7-6 (min.0-3-10),AC=168139-7-6 (min.0-3-10),AB=168/39-7-6 (min.0-3-10),AA=169/39-7-6 (min.0-3-10),Z=164/39-7-6 (min.0-3-10).Y=182/39-7-6 (min.0-3-10),X=110/39-7-6 (min.0-3-10).W=309/39-7-8 (min.0-3-10). B=216/39-7-6 (min.0-3-10) Max Horz B=109(LC 12) Max UpliftAF=-20(LC 12),AG=-26(LC 12).AH=-24(LC 12),AI=-24(LC 12).AJ=-24(LC 12),AK=-26(LC 12),AL=-16(LC 12),AM=-45(LC 12), AD=-18(LC 13),AC=-27(LC 13),AB=-24(LC 13),AA=-24(LC 13).Z=-24(LC 13),Y=-26(LC 13).X=-15(LC 13),W=-50(LC 13),B=-4(LC 13) Max GravV=129(LC 20),AE=167(LC 25),AF=243(LC 19),AG=240(LC 19),AH=202(LC 19),AI=169(LC 1),AJ=165(LC 19),AK=185(LC 1), AL=101(LC 19).AM=326(LC 1),AD=246(LC 20).AC=243(LC 20),AB=214(LC 20),AA=169(LC 1),Z=165(LC 20).Y=182(LC 1),X=111(LC 20).W=309(LC 1),B=216(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-13=0/41,B-AN=-120/34,C-AN=-110/64,C-D=-88/52,D-E=-66/61,E-F=-54/76,F-G=-41/90,G-H=-39/103, H-1=-29/106,I-J=-49/132,J-K=-59/169,K-L=-67/210,L-M=-67/210,M-N=-59/169,N-O=-49/132, O-P=-29/106,P-Q=-39/103,Q-R=-36/78,R-S=-36/51,S-T=-36/27,T-AO=-50/13,U-AO=-57/3,U-V=-90/42 BOT CHORD B-AM=-27/105,AL-AM=-27/105,AK-AL=-27/105,AJ-AK=-27/105,AI-AJ=-27/105,AH-AI=-27/105, AG-AH=-27/105,AF-AG=-27/105,AE-AF=-27/105,AD-AE=-27/105,AC-AD=-27/105,AB-AC=-27/105, AA-AB=-27/105,Z-AA=-27/105,Y-Z=-27/105,X-Y=-27/105,W-X=-27/105,V-W=-27/105 WEBS L-AE=-127/0,K-AF=-203/88,J-AG=-200/80,I-AH=-163/52,G-AI=-128/56,F-AJ=-126/53,E-AK=-138/61, D-AL=-87/36,C-AM=-230/122,M-AD=-206/88,N-AC=-203/80,O-AB=-174/52,Q-AA=-128/56,R-Z=-127/53, S-Y=-136/61,T-X=-94/37,U-W=-214/148 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-11-9,Exterior(2)2-11-9 to 16-0-0,Corner(3) 16-0-0 to 20-0-0,Exterior(2)24-0-0 to 35-7-13 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by Con2tiR-O fln pa t�etween the bottom chord and any other members. a �: job JTrM — TuT SS type y W— OMES 251"RF 2514-A N GABLE 1 1 Job Reference o_bnal 8MC,EVERETT,WA 962053212 8.000 s Jut 15 2016 MITok tndustrioa,Inc Mon M8YY 08 15:14.38 2017 Pag90 2 ID:migzTLjh7H1sSOCFVTnR06zlaVJ-rVVP8rw2r RE5hgFsrv7lbRm36OwTTn7rhWJ99MzIV81 NOTES- 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 20 lb uplift at joint AF,26 lb uplift at joint AG,24 lb uplift at joint AH, 24 lb uplift at joint Al,24 lb uplift at joint AJ,26 lb uplift at joint AK,16 lb uplift at joint AL,45 lb uplift at joint AM,18 lb uplift at joint AD,27 lb uplift at joint AC,24 lb uplift at joint AB,24 lb uplift at joint AA,24 lb uplift at joint Z,26 lb uplift at joint Y,15 lb uplift at joint X,50 lb uplift at joint W and 4 lb uplift at joint B. 13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. r :� ti �� 1 I Prescriptive Energy Code Complio..,:e for All Climate Zones in Washington Project Information Contact Information Plan 2514 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Value' U-Factor Fenestration U-Factor' n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC -" n/a n/a Ceilingk 0 0.026 Wood Frame Wallg.m,n 21 int 0.056 Mass Wall R-Value' 21/21" 0.056 Floor 30a 0.029 Below Grade W all"01 10/15/21 int+TB 0.042 Slab"R-Value&Depth 10,2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1.Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. E2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. 03.Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 ❑ lb Efficient Building Envelope 1 b 1.0 ❑ 1c Efficient Building Envelope 1c 2.0 ❑ 1d Efficient Building Envelope 1d 0.5 ❑ 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 2b 1.0 El 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 1.0 1.0 3b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 3c 1.5 ❑ 3d High Efficiency HVAC 3d 1,0 ❑ 4 High Efficiency HVAC Distribution System 1.0 P1 1.0 5a Efficient Water Heating 5a 0.5 0 0.5 5b Efficient Water Heating 5b 1.0 1.0 5c Efficient Water Heating 5c 1.5 ❑ 5d Efficient Water Heating 5d 0.5 ❑ 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions Received on 11 ?017 Nr) lin :z I �� ., , - .� �� �: y Table R402.1.1 Footnotes For SI: 1 foot.=304.8 mm,ci .=continuous insulation, int.=intermediate framing. "R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. ` "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall."10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. ` Reserved. 8 Reserved. h Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. J Reserved. k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. Reserved. m Int.(intermediate framing)denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section R402.1.3. 3 Window, Skylight and Door Schedule Project Information Contact Information Flan 2614 Width Height Ref. U-factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door(24 sq. ft. max.) 0.0 0.00 Exempt Glazed Fenestration (15 sq. ft. max.) F 10.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA Foyer 0.30 1 3 6 20.0 6.00 0.30 1 2 ° 6 17.8 5.33 Guest 0.30 1 3 5 15.0 4.50 Great Room 0.30 1 5 15 25.0 7.50 Dining 0.30 1 6 1 6 10 41.0 12.30 Great Room 10.30 1 3 5 15.0 4.50 Master Bedroom 10.30 1 5 5 25.0 7.50 Stairs 0.30 1 2 2 4.0 1.20 Bedroom 2 0.30 1 3 5 15.0 4.50 Bedroom 3 0.30 1 15 5 25.01 7.50 Bonus Room 0.30 1 3 5 15.0 4.50 Bedroom 4 10.30 1 2 2 4.0 1.20 0.30 1 3 5 15.0 4.50 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.01 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0,00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.01 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 i _ 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 o.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 236.8 71.03 Vertical Fenestration Area Weighted U=UA/Area 0.30 Overhead Glazing(Skylights) Component Width Height Description Ref. U-factor Qt. Feet inch Feet '`ch Area UA O.Oj 0.00 0.01 0.00 0.01 0.00 0.01 0.00 0.01 0.00 o.0 0.00 Sum of Overhead Glazing Area and UA 0.01 0.00 Overhead Glazing Area Weighted U=UA/Area 1 0.00 Total Sum of Fenestration Area and UA (for heating system sizing caicu►ations) 1 236.81 71.03 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals ,Land S This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should bo used to determine cooling loads The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at (360)956-2042 for assistance. Project Information Contact Information Plan 2514 Heating System Type: O All Other Systems Q Heat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions Marysville Design Temperature Difference(AT) 47 A=Indoor(7O degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 2,514 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 9.3 23,380 Glazing and Doors U-Factor X Area = UA Instructions 0.30 237 71.10 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructions R 49 0.026 1,513 39.34 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions — I seteet R•value J No selection -- Above Grade Walls(see Figure 1t U-Factor X Area UA Instructions R-21 Intermediate 0.056 F 2.670 149.52 i - Floors U-Factor X Area UA Instructions 0.029 1.513 43.88 R-30 Below Grade Walls(sea Figure 1) U-Factor X Area UA Instructions No Below Grade Walls In this project. -- Slab Below Grade(see Figure n �yf F-Factor X Length UA Instructions SeWconditiemng No selection li-'-JI --- Slab on Grade(see Figure 1) F-Factor X Length UA Instructions it No Slab on Grade in this project. Location of Ducts Instructions _ Duct Leakage Coefficient Conditloned Space 1 1.00 Sum of UA 303,84 Envelope Heat Load 14,280 Btu I Hour Figure 1. SumotUAXAT Air Leakage Heat Load 11,B68 Btu/Hour VoNmeX 0.6X6TX.018 Aoovecoda Building Design Heat Load 26,148 Btu I Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 26,148 Btu I Hour Ducts in unconditioned space:Sum of Building Heat Loss X 1,10 Ducts in co"Yoned space:Sum of Budding Heat Loss X 1 Maximum Heat Equipment Output 36,607 Btu I Hour Building and Duct Heat Loss X 140 for Forced Air Furnace Building and Duct fleet Loss X 125 for Heat Pump (07y01113) NASH&ASSOCIATES ARC14ITECTS PLAN 2514 BEAM, LATERAL & SEISMIC CALCULATIONS GISTER ' �t f�fi r -:1ARy OMAS NASH F)TATE OF WASHINGTON MYrw �,aJ11lJ�` Received OCT 31 �V7 2015 IBC JULY 1, 2016 8003 118th AVE NE Kirkland, WA 98033 (426) 828-4117 WWW.NASH-ARCHITECTS.COM NASHARC CLIENT: ASSOCIATES BEAM DESIGN DATA PROJECT- DATE: ARCHITECT'S DATE,: NAME: Roof Loads: LL 25#/sf DL 15 #/sf Total 40#/sf Unless Noted Otherwise Floor Loads: LL 40#/sf DL 10 #/sf Total 50#/sf Deck Loads: LL 60#/sf DL 10 #/sf Total 70#/sf So1L- 1500 PSF Min. Concrete: Per IBC 15 Masonry. Per IBC 15 Steel: Per IBC 15 Wood: Per IBC 15 Nailing: Per IBC 15 4" Beam: Douglas Fir #2 fv = 160 fb = 900 PSI E = 1,600,000 6" Beam: Douglas Fir #2 fv = 170 fb = B75 PSI E = 1,300.000 Joints & Hem Fir #2 Rafters: fv = 150 fb = 850 PSI E = 1,300,000 Glu—Lam Beams: fv = 240 PSI fb = 2,400 PSI (reduced by size factor, CF•KI) E = 1,800,000 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WW1P.NASH—ARCHITECTS.COM PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 RB-1 Date: 10/24/16 Selection 4x 10 DF-L#2 Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=3.4 in2 R2=3.4 in (1.5)DL Defl= 0.02 in Data Beam Span 5.0 ft Reaction 1 LL 1313# Reaction 2 LL 1313# Beam Wt per ft 7.87# Reaction 1 TL 2120# Reaction 2 TL 2120# Bm Wt Included 39# Maximum V 2120# Max Moment 2650'# Max V(Reduced) 1466# TL Max Defl L/240 TL Actual Defl L 1>1000 LL Max Defl L/360 LL Actual Defl L/>1000 Attributes Section(n') Shear(in') TL Defl(in) LL Defl Actual 49.91 32.38 0.04 0.02 Critical 29.44 12.22 0.25 0.17 Status OK OK OK OK Ratio 59% 38% 15% 12% Fb(psi)_ Fv(psi) E(psi x mil Fc (psi) Values Reference Values 900 180 1.6 625 Adjusted Values 1080 180 1.6 625 fldush1/WI is CF Size Factor 1.200 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:525 Uniform TL: 840 =A Uniform Load A j R 1 =2120 R2=2120 SPAN=5FT Uniform and partial uniform loads are Ibs per lineal ft. r PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 RB-2 Date: 10/24/16 Selection 4x 10 DF-L#2 Lu=0.0 Ft 1 Conditions NDS 2015 Min Bearing Area R1=3.4 in' R2=3.4 in' (1.5)DL Defl= 0.02 in Data Beam Span 5.0 ft Reaction 1 LL 1313# Reaction 2 LL 1313# Beam Wt per ft 7.87# Reaction 1 TL 2120# Reaction 2 TL 2120# Bm Wt Included 39# Maximum V 2120# Max Moment 2650'# Max V(Reduced) 1466# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max Defl L/360 LL Actual Defl L/>1000 Attributes Section in') Shear(ml) TL Defl(in) LL Defl Actual 49.91 32.38 0.04 0.02 Critical 29.44 12.22 0.25 0.17 Status OK OK OK OK Ratio 59% 38% 15% 12% Fb(psi) Fv(psi) E(psi x mil Fc (psi) Values Reference Values 900 180 1.6 625 Ad'usted Values 1080 180 1.6 625 Adiustments CF Size Factor 1.200 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL: 525 Uniform TL: 840 =A Uniform Load A /'\1 R1 =2120 R2=2120 SPAN=5FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 B-1 Date: 10/24/16 Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu=0.0 Ft J Conditions NDS 2015 Min Bearing Area R1=6.6 in R2=6.6 in (1,5)DL Defl= 0.06 in Recom Cambe-0.10 in Data Beam Span 6.0 ft Reaction 1 LL 2775# Reaction 2 LL 2775# Beam Wt per ft 6.83# Reaction 1 TL 4281 # Reaction 2 TL 4281 # Bm Wt Included 41 # Maximum V 4281 # Max Moment 6421 '# Max V(Reduced) 3210# TL Max Defl L/240 TL Actual Defl L/504 LL Max Defl L/360 LL Actual Defl L/914 Attributes Section (in') Shearon') TL Def�in LL Defl Actual 42.19 28.13 0.14 0.08 Critical 32.10 20.06 0.30 0.20 Status OK OK OK OK Ratio 76% 71% 48% 39% Fb (psi) Fv(psi) E(psi x mil Fc (psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:925 Uniform TL: 1420 =A Uniform Load A R1 =4281 R2=4281 SPAN=6 FT Uniform and partial uniform loads are Ibs per lineal ft. �, I PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 B-2 Date: 10/24/16 Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=5.6 in2 R2=2.6 in (1.5) DL Defl= 0.02 in Recom Cambe -0.03 in Data Beam Span 5.0 ft Reaction 1 LL 2423# Reaction 2 LL 1215# Beam Wt per ft 6.83# Reaction 1 TL 3666# Reaction 2 TL 1658# Bm Wt Included 34# Maximum V 3666# Max Moment 3013'# Max V(Reduced) 2633# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max DO L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(in') TL Defl(in) LL Defl Actual 42.19 28.13 0.05 0.03 Critical 15.07 16.46 0.25 0.17 Status OK OK OK OK Ratio 36% 59% _ 19% 17% Fb(psi) Fv(psi) E(psi x mil Fc (psi) Values Reference Values 2400 240 1.8 650 Adiusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 1313 B=2120 1.0 885 H= 1370 0 1.0 360 1=450 1.0 5.0 I [ H Pt loads: B R1 =3666 R2= 1658 SPAN = 5 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 GB-1 Date: 10/24/16 Selection 5-1/8x 19-1/2 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1= 17.6 in'R2= 13.9 in2 (1.5) DL Defl= 0.19 in Recom Camber=0.28 in Data Beam Span 16.0 ft Reaction 1 LL 7544# Reaction 2 LL 6185# Beam Wt per ft 24.28# Reaction 1 TL 11440# Reaction 2 TL 9053# Bm Wt Included 389# Maximum V 11440# Max Moment 46400'# Max V(Reduced) 9093# TL Max Defl L/240 TL Actual Defl L/440 LL Max Defl L/360 LL Actual Defl L/769 Attributes Section(in') Shear(in') TL Defl (in) LL Deft Actual 324.80 99.94 0.44 0.25 Critical 237.01 56.83 0.80 0.53 Status OK OK OK OK Ratio 73% 57% 55% 47% Fb(psi) Fv(psi) E(psi x mil Fc (psi) Values Reference Values 2400 240 1.8 650 Adiusted Values 2349 240 1.8 650 Adjustments Cv Volume 0.979 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Point LL Point TL Distance_ Par Unif LL Par Unif TL Start End 1313 B=2120 2.5 925 H= 1420 0 2.5 1313 C=2120 7.5 400 1=500 2.5 7.5 1838 D=2964 10.0 925 K= 1420 7.5 10.0 440 L=550 10.0 16.0 f L 1 K Pt loads: - 0 R1 = 11440 R2=9053 SPAN= 16FT Uniform and partial uniform loads are Ibs per lineal ft. i CLIENT: NASH-ASSOCIATES WIND AND SEISMIC, DE516N DATA PROJECT: A R 1-.1 1 1 1 E C T s PER 2015 IBC, DATE: NAME: WIND DESIGN GRITERIA DESIGN PER ASGE 7-10 I. NOMINALA LTIMATE WIND SPEED V/asd /Vult 85/110 mph 2. RISK CATEGORY II 1.00 3. WIND EXPOSIFLE CATEGORY "B" 4. INTERNAL PRESSURE COEFFICIENT +/-55 5. COMPONENTS AND CLADDING DESIGN PRESSURE +/- 16 psf BUILDIN65,STRUCTURES,AND PARTS THEREOF SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH STRE146TH DESIGN,LOAD, AND RESISTANCE FACTOR DE516N, ALLOWABLE 5TRE55 DESIGN, EMPIRICAL DE516N OR CONVENTIONAL GONSTRUGTION METHODS, AS PERMITTED BY THE APPLICABLE MATERIAL CHAPTER, SECTION 1604.1 BUILDIN65, 5TRUGTURE5, AND PARTS THEREOF,SHALL BE DESIGNED TO WITHSTAND WIND LOADS A5 DEFINED IN SECTION Well AND ASGE 7-10 SIMPLIFIED METHOD TO BE USED FOR WIND DESIGN PER A5GE 7-10,SECTION 27.5 (BUILDING HE16HT 15 LE55 THAN 160 FEET) 110 MPH ULTIMATE WIND SPEED USE lqb P5F PER TABLE 27.6.1 "EXPOSURE B" WOOD DESIGN PER SECTIONS 2304-2306.5TRUCTURES USING WOOD SHEAR WALLS AND DIAPHRAGMS TO RE515T WIND,5EI5MIG, AND ALL OTHER LATERAL LOADS SHALL BE DESIGNED AND CONSTRUCTED IN AGCORDANCE WITH AF 4 PA 5DPW5 AND PROVISIONS OF SECTIONS 2505-2506 5E15MIG DE516N DATA DESIGN PER A56E 7-10/SECTION 1613 I. SEISMIC, IMPORTANCE FACTOR le 1.00 2. SHORT PERIOD ACCELERATION 55 1.66 *see footnote at bottom of page 3. 1 SECOND ACCELERATION 51 0.-14b *see footnote at bottom of page 4. SITE CLA55 D (default class per 15G) 5.SPECTRAL RESPONSE COEFFICENT Scs 0,112 *see footnote at bottom of page 6. SPECTRAL RESPONSE COEFFICIENT Sw 0.148 *see footnote at bottom of page 7. SEISMIC DESIGN CATEGORY D 8. SEISMIC FORGE RESISTING SYSTEM PLYWOOD SHEAR WA11-5 q. DE516N BASE SHEAR (see seismic calculations) 10. SEISMIC- RESPONSE CDEFFIGENT G3 0.15 II. RESPONSE MODIFICATION FACTOR R 65 12. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORGE 15. RISK CATEGORY II THE ANCHORA6E OF WALLS SUPPORTING CONSTRUCTION SHALL BE BE DESIGNED IN ACCORDANCE WITH ASCE 7-10, SECTION 12.11.2 IN STRUCTURES A5516NED TO SEISMIC, DESIGN CATEGORY C-F,COLLECTOR ELEMENTS AND THEIR CONNECTIONS TO VERTICAL E1 FMENT5 SHALL BE DESIGNED TO RESIST MAXIMUM EFFECTS AS SPECIFIED IN A5CE 7-10,SECTION 12.10.2.1 BASE SHEAR V= (F 5M/R) W ANCHOR BOLTSo 5/8" VIA X 10,A507 OR BETTER W/7" MIN. EMBEDMENT. V= 1104#/BOLT • PER U565,THE MAXIMUM SI IN THE STATE OF WASHINSTON 15 0.748. ALL SEISMIC DESIGN VALUES USED IN THIS ANALYSIS ARE BASED UPON THIS NUMBER. SINGE 5115 LESS THAN 0.75,THEN USE SEISMIC, CATEGORY D IF RISK CATE60RY 15 I, 11,OR III 6003 118th AVE NE Kirkland, WA 98033 (425) 826-4117 YIWW.NA3H-ARCHITECTS.COM y I)- Lli [TEE ❑❑❑❑ LL N 0. i i i i i i I I O� N N � � N � k V S ` k ❑ 41 N N k � N N � N �r 9 /d I �S CV. 1 V ti r^ � V o LATERAL CALCULATIONS CLIENT:- NASH-ASSOE CIATES PROJECT: WIND WORK3HEET ARCHI f' ('TS DATE: 85 MPH/110 MPH= NOMINALA&TIMATE WIND SPEED NAME: 19.6 PSF FRONT ELEVATION LEFT ELEVATION _REAR ELEVATION RIGHT ELEVATION LOCATION TOTAL SHEAR FORCE (¢#) SHEAR UNIT SHEAR W z H z (see chart for wind pressure WALL SHEAR WALL 0 specified height) LENGTH (ft) (#/ft) TYPE l �P 17, 5x0 kr4, 6 l 37 3 -�— Z 141,p (z'�' Y'q x c g) (o ) 341 ?ter 3 g 30 60 Xgxr4�� l ;lul (7, S-x-1 x «i 6l f 30'9 7 144 ( � �•G ) �~301� 7 q, 3 � 13IVI (zok� �tg,,6 C Z/zx 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHITECTS.COM r I` I` I CLIENT: NASH a-ASSOCIATES SEISMIC ANALYSIS PROJECT: ARCHII'ECTS DATE:__ NAME: 1 Weight of Building: Roof Assembly: Asphalt Shingles - 2.00#/ft Cedar Shakes - 2.25#/ft Tile - 9.50#/ft Felt - 0.15 #/ft Felt - 0.15 #/ft Felt - 0.15 #/ft 1/2" Plywood - 1.50 #/ft 1/2" Plywood - 1.50 #/ft 1/2" Plywood - 1.60 #/ft Trusses 0 24" o.c. - 1.75 #/ft Trusses ® 24" o.c. - 1.75#/ft Trusses 6 24" o.c. - 1.75 #/ft R-38 Insulation - 2.35#/ft R-30 Insulation - 2.25#/ft R-30 Insulation - 2.25#/ft 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft Total 9.75#/ft Total 9.90#/ft Total 17.90#/ft Use 10.00#/ft Use 10.00#/ft Use 18.00#/ft lot do 2nd Floor Assembly: Carpet / Pad - 0.50#/ft Hardwood - 2.50#/ft 3/4' T&G Plywood - 2.50#/ft 3/4" T&G Plywood - 2.50#/ft 2x10 ® 16" O.C. 2,30#/ft 2x10 W 16" o.c. - 2.30#/ft 1/2" GWB Ceiling - 2:00#/ft 1/2" GWB Ceiling - 2.00#/ft Total 7.30#/ft Total 9.30#/ft Use 10.00#/ft Use 10.00#/ft Interior Wall Assembly: Exterior Wall Assembly. 1/2" GWB - 2.00#/ft 3/4" Wood Siding -- 2.30#/ft 2X4 ® 16" o.c. - 1.10 #/ft 1/2" Plywood - 1.50 #/ft 1/2" GWB - 2.00#/ft 2x6 ® 16" o.c. - 1.37 #/ft Total 5.10 #/ft R-21 Insulation - 2.10 /ft Use 8.00#/ft 1/2" GWB - 200 /ft Total 9.27#/ft Use 10.00#/ft 4" Brick Veneer - + 3.20#/ft 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH-ARCHITECTS.COM CLIENT: NASH-ASSOCIATES SEISMIC ANALYSIS PROJECT: ARr_11ITEC1S DATE- NAME: 2 — - - SEISMIC: V = (C.) (Wdl) (Plywood) 2nd Level: Roof: (Asphalt / Cedar Shake) 10#/ft X .50 5- sf = �_-m _ or (-Pile) 18#/ft X sf = Exterior Walls; L x 10#/sf x 1/2 (h) /&I N/o k t/ — o-� (E2) Interior Walls; L x 8#/s� 1/2 (h) S�y Q (I � k� TOTAL, _ _Z&q 7 0 1st Level: Roof: (1st Floor Roof) 10#/ft X sf = 2nd Floor. 10#/ft X_/y sf = (� Exterior Walls: (E2) + L x 10#/sf x 1/2 (h) I 7 b go,0q /6 Z k-1 o kH, T' 70 (E1) Interior Walls: (Io + L x 8#/sf x 1/2 (h) 5 tf of F 9 o X"? KLf' - $ 3 2� cI l) TOTAL m 3& V 3 y C f o9 Basement: 1st Floor. 10#/ft X .sf = Exterior Walls: (E1) + L x 10#/sf x 1/2 (h) Interior Walls: (I1) + L x 8#/sf x 1/2 (h) TOTAL _ 8003 liBth AVE NE Kirkland, WA 98033 (425) 928-4117 WWW.NASH—ARCHITECTS.COM 711�1 qNASH=ASSOQ CLENT: ATES SEISMIC ANALYSIS PROJECT:H1TE:CTS DATE: NAMF: 3 BASE SHEAR: 6A5E SHEAR V= (F 5vs/R) W V= F (.ql2)/6.5= .14q LEVEL 2: Wdl 2Z(v. ! # x 0.149 = W/O U LEVEL 1: Wdl ,!P t y/ # x 0.149 = S- W Z TOTAL:- Wdl 3, —/ # x 0.149 = je K 2 (V) Dead Load Hei ht Moment Shear ® Stor Level Fx = [(Wdl)(h)T Remarks (Wdl) (h� (Wdl)(h) (Wdl)(h) y�,u, 7(�i/til � S 37 36y 3&KCq, 4Z 1 9, Z o Total 631 LA 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHITECTS.COM i NASH k ASSOCIATES cMNm di n IC 111 T F; -r SEISMIC ANALYSIS PROJECT_ _ DATE: NAME: 4 x � cr OU sx � M 0 x w op q kn QO >�� O`� Qj n a E- s H ca ` CSC �+ N N U] �, N W z a 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW N-,AS�I-I-ARCHITEC TMJNASH&ASSOCIATESCIJENT: SEISMIC ANALYSIS PROJECTc HITLCTS DATE: NAME:_ _ 5 Redundancy Factor (p): 1. Maximum allowable wall shear for p<=1 Vumax = (2)(Vaccstory)/Ab l/2 2. Maximum actual shear Vmax = Largest seismic wall shear 3. p = 2—[2(Vaccstory)/(Vumax)(Ab 1/2) r 3v� z� o% 6 � f 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHITECTS.COM J - • I I • ' Date: 04/10/2026 Permit#: 1720 Perm t Date: 11/01/2017 Review Date: 11/01/2017 Perm Type: RESIDENTIAL SINGLE FAMILY Review Type: RESIDENTIAL SINGLE FAMILY Target Date: 11/08/2017 Scheduled Time 00:00 Com pleted Date: 11/02/2017 Description: Site plan m xts all land use regulations. Review Status: Assigned To: Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information Parcel#: 01166900000500 L GI HOMES -WASHINGTON LLC LGI HOMES -WASHINGTON LLC 1 450 LAKE ROBBINS DR STE 430 9026 168th Street NE T HE WOODLANDS, TX 77380 Zoning: 111 Single Fam iy Residence - DetachedLot: 5Block: Permit#: 1720 Permit Date: 11/01/17 Permit Type: RESIDENTIAL SINGLE FAMILY Project Nam e Gregory Park Applicant Nam a LGI Horn cs -Washington, LLC Applicant Address: 9028 168th Street NE Applicant, City, State, Zip: Arlingotn,WA98223 Contact: Matt Adam s Phone: 425-785-0797 Em al: m at.adam s@lgihom cs.com Scope of Work: New SFR Valuation: 309450.70 Square Feet: 2894 Num ber of Stories: 2 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/28/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wrier Nam e Ovner Phone Zoning LGI HOMES- 01166900000500 9 026 168th Street NE WASHINGTON Residence Single Dam iy -Detached LLC Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# LGI HOMES- 12951 BELRED CONSTRUCTION Labor and LGIHOHL857MB WASHINGTON LLC RD#150 CONTRACTOR Industries Inspections Date I nspection Type D escription S cheduled Date C om Iieted Date I nspector S tatus 01/22/2018 R20.SFR/DUPLEX Com Iieted FINAL Plan Reviews Date R eview Type D escription A ssigned To R eview Status 11/01/2017 RESIDENTIAL SINGLE Site plan m e is all land use regulations. FAMILY 11/01/2017 RESIDENTIAL SINGLE BUILDING FAMILY Fees Fee D escription N otes A m cunt Building Perm i T able 4-1 $3,076.58 Building Plan Review T able 4-2 $1,999.78 Forced Air Heat f ee per Btu $25.00 Gas Piping/Units E nter#of units $10.00 Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base P erm i Fee $25.00 Park-Com m nity SF S ingle Fam iy $1,662.00 Plum hng Base Perm i Fee $25.00 M echanical Com m mial Perm i T able 4-7;Per Unit 1 6 @$12 $192.00 Processing/Technology $25.00 State Surcharge- 1 st DU R esidential- 1 st Unit $4.50 Traffic Mitigation-SF S ingle Fam iy $3,355.00 Wier Heater(Tank) $25.00 Total $10,449.86 Attached Letters Date Letter D escription 11/14/2017 Building Perm i Paym arts Date Paid By D escription P aym a►t Type A ccepted By A m aunt 11/O1/2017 LGI Hom cs-Washington Check#5717 K ristin Foster $8,450.08 LLC 11/01/2017 LGI Hom cs-Washington Check#5716 K ristin Foster $1,999.78 LLC O utstanding Balance $0.00 Notes Date Note C reated By: 11/01/2017 Application needs signature.KF K ristin Foster Uploaded Files Date File Nam e 11/28/2017 2803061-1720 Issued Perm i.pdf 11/02/2017 2751656-1720 Signed Application.pdf 11/01/2017 2747541-1720 Apnlication.pdf 11/01/2017 2747542-1720 Site Plan.pdf