HomeMy WebLinkAbout9016 168th Street NE_BLD1718_2026 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development N City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: Plat: 9016 168th Street NE Gregory Park Lot 3 . . 1 Single-family ❑ Duplex Oj Townhouse 01 Addition ❑ Accessory structure Proposed Area: 111 Floor: 1076 2nd Floor: 1438 Garage: 380 Total SF: 2894 Describe Proposal (include cross street): Application for new single family residence to be located at 9016 168th Street NE. Cross street is 91st Valuation: Owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City: State: Zip Code:Arlington WA 98223 _ _ _ Phone: 425-785-0797 Email:matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 _ Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 6/16LP Page 1 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development y'P O City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 lINC Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) 6! Bath/Shower Combo (4.0) x 2 Chi Sink (1.5) x 1 91 Shower (2.0) x 1 &1 Lavatory (1.0) x 5 ❑,j Clothes Washer (4.0) x Water Closet(2.5) x 3 ek Dishwasher (1.5) x 1 [4; Water Heater x 1 4 Hose Bibb (2.5) x 2 Water Heater Model # ek Other (list) x 1 AO Smith HPTU - 50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: ABS Proposed Piping Material: PEX Proposed DWV Size: 2" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 j`s�` °�' RESIDENTIAL PERMIT APPLICATION 'y Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: FOI Furnace (80+) Model# Bryant 915SA30040514 AFUE 95% Ol Heat Pump Model# SEER HSPE 01 AC Unit Model# SEER ❑ Type ll Hood 01 Commercial Cooking Appliance ❑ Hydronic Piping 01 Boiler 01 Solid-Fuel Appliance ❑ PV System 01 Fireplace Insert Ol Outdoor BBQ ❑ Storage Tank 2! Freestanding Stove ) Gas Piping ❑ Other Gas Piping Information Not Applicable: 01 Black Steel Pipe Material: Pipe Size: 1" Total BTU's of all Appliances: 120,000 Distance from Meter to Furthest Appliance: 5 • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: &161P Page 3 of 3 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 qW PHONE; (360) 403-3551 BUILDING PERMIT Address:9016 168th Street NE Permit#:1718 Parcel#:01166900000300 Valuation:309450.70 OWNER APPLICANT CONTRACTOR Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC Address: 1450 LAKE ROBBINS DR STE 430 Address:9028 168th Street NE Address: 11410 NE 124th Street,Ste#103 City,State Zip:THE WOODLANDS,WA 77380 City,State Zip:Arlingotn,WA 98223 City,State Zip:Kirkland,WA 98034 Phone: Phone:425-785-0797 Phone:360-353-0588 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Single Family Residence CODE YEAR: 2015 STORIES: 2 CONST.TYPE: V-$ DWELLING UNITS: 1 OCC GROUP: R-3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC1I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded Ci " gt #3101. / Signature Print Name Date Released By 16ate CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/14/2017 Building Permit Fee $3,076.58 11/14/2017 Building Plan Review Fee $1,999 78 11/14/2017 Furnace $25.00 11/14/2017 Gas Outlets Base Fee 1 to 5 $10.00 11/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00 11/14/2017 Mechanical Permit Base Fee $25.00 11/14/2017 Park-Community SF $1,662.00 11/14/2017 Plumbing Permit Base Fee $25.00 11/14/2017 Plumbing Permit Fee(Enter Fixture Fee) $192.00 11/14/2017 Processing/Technology Fee $25.00 11/14/2017 State Building Code Surcharge Fee $4.50 11/14/2017 Traffic Mitigation-City $3,355 00 11/14/2017 Water Heater $25.00 Total Due: $10,449.86 7btal PaNmcnt: SIQ.4k9 So 13n1ancc Due: SD.IIO CALL FOR INSPECTIONS BUILDING(360)403-3417 When caging for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RESIDENTIAL PERMIT APPLICATION Department of Community& Economlc Development City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9016 168th Street NE Plat: Gregory Park Lot 3 Single-family ❑ Duplex ❑ Townhouse ❑ Addition ❑ Accessory structure Proposed Area: I" Floor: 1076 2nd Floor: 1438 Garage: 380 Total SF: 2894 Describe Proposal (include cross street): Application for new single family residence to be located at 9016 168th Street NE. Cross street is 91st Valuation: Owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State: WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 _ Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 enrceivCO 6/16LP Page 1 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: Bryant 915SA30040514 95% Furnace (80+) Model# AFUE �I Heat Pump Model# SEER HSPE ❑ AC Unit Model# SEER Q Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System J Fireplace Insert ❑ Outdoor BBQ ❑ Storage Tank Freestanding Stove Gas Piping ❑ Other Gas Piping Information Not Applicable: Black Steel Pipe Material: Pipe Size: 1" Total BTU's of all Appliances:120,000 Distance from Meter to Furthest Appliance: 25 • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances A shut-off is required within 6 feet of all appliances i l Applicant Signature: Date: Print Applicants Name: n 6/16LP Page 3 of 3 SETBACKS� j I 168TH ST. NE fRXr 2o' NOTES. 8"NAIOP S,� 5, BUILDING D/A/EMA'ANS ARE lid FA67 LIF FOLINDAAOW REAR 5' •GIWKY0 9YONN AS D V6W 4f00 r— AC7UAL LOCAAOW A/AY VARY B.SEA Jt0o ,m��mABE INsi�PER Affl°OP NAIDP pry OIL ARL/NGT6KF STANDARD COIWDP( ) SERNCE •SYL r FEN6F 70 BE INSTALLED X LWAD/OVT SIDE OIL BOLDING imi ° e s y y v Y - PARCEL •CONSAPUCACIV ENTRANCE 7O BE INSTALLED POP arY OF ARL/NGTLYV F STANDARD.£ STORM NOTES: 8 - — ` -� - •7ESC INSTALLED PR16R 70 ° C067RUCACW S7WM Cl'£ANL1'/T. ��'. ()Ip' -BARE SOILS C0147PED INAV A/ULLYI CGIVNECr ROLL AND BSI 471 SJ� X AA(07H&APPR00 bMP FOOANG ORNNS D A� a •70PSOIL P£R #500f BI/P T51J — — —— —— �89. 11.0D — — � — — - .( OWSJ'D&U GI�F 010WNEC1f71 TO /�L5�00 PRVAIE 1 7 TOP 463.5 ° I STOYPA/ PRlVA7E S7CiIPA/SNUB TOE 461.o 24.00 I EA DVT 'q7E 9YAD BE STABILIZED PRIOR S£NERJ GARAGE 10 BU/LL7ING POPI//T BEING LY.WNECW R�, I 10.00'PUBLIC RNAL/ZED f BUILDING I U&ITY SITE NOTES.' WVNE I EASEA/OVT ,776HRINE FOonNO DRNNS AND &ls7ING +I LOO'RO IF ROOF DRAINS TO PERMANENT g 14£RNANG ST6RM ORMNAGE SYSISM PER LOT 3 0 LLIV1tAf/R((7)P.) I APPROWD PLAT DRAINAGE PLAN TOP 463.5 I - CIV FILE W7H 7NE C1OUN7Y. 1.7 TOE 461.8 fRaD Q RESYLIEW g I AREA OF D1S7URBAN6E/NCYUDES PALIY-2514 GARAGE LEFT I SNARE LOT. 7Gt 00'WALLIPRAW I 1,679fSF EASEMENT I - I LEGEND: BI moo o- BLOW OfF \ - ® NA7ER A/E7OP \ I�PAnO 12 SF i i 4( RRE HYDRANT � NR VAC ,�ao'Bset—I I 1.7 T�46 4615 1..6 I I 0 ILA CA7W BASrN \ RN/.M CQVW R I I O afAVaIT MANHGYE , I ® BLOff HALL 7REE REMOVAL OCT �y a SC4LE 1'=20' LOT 3 r i ` SITE PLAN GREGOR Y RARK LGI HOMES PLAN NO. PALIX-2514 LO/(/r'C T�A`REA = 5,,773 SF DATE 912912017 PARCEL # LOT J Hl/ = 1,679 14711 NE 29M Pl—,#701 DRIWHAY= 471 SF Bellevue,was^;^910 98007 DESIGNED CORE ADDRESS 9016 1687H Sr NE 425.985.7877 Fax 425.885.7963 WALKNAY/PAPO = 12 SF PROJECT NUMBER TOTAL= 2,162 Sr ENGINEERING PLANNING • SURVEYING DRAWN CAF 13024L-GRGOO BUILDING INSPECTION REPORT— Downspout Connection Permit No. BLD1718 Address: 9016 168th Street NE Contractor: LGI Owner: LGI Date: 1/17/2018 ❑ APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER i INSPECTION: Downspout Connection Date: 1/17/2018 Inspector: i - _ - CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:9016 168th Street NE Permit#:1718 Parcel#:01166900060300 Valuation:309450.70 OWNER APPLICANT CONTRACTOR Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC Address: 1450 LAKE ROBBINS DR STE 430 Address:9028 168th Street NE Address: 11410 NE 124th Street,Ste#103 City,State Zip:THE WOODLANDS,WA 77380 City,State Zip:Arlingotn,WA 98223 City,State Zip:Kirkland,WA 98034 Phone: Phone:425-785-0797 Phone:360-353-0588 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Single Family Residence CODE YEAR: 2015 STORIES: 2 CONST.TYPE: V-B DWELLING UNITS: 1 OCC GROUP: R-3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION 14AS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City gt #3101. b ^ Signature Print Name Date Released By bate CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/14/2017 Building Permit Fee $3,076.58 11/14/2017 Building Plan Review Fee $1,999.78 11/14/2017 Furnace $25.00 11/14/2017 Gas Outlets Base Fee 1 to 5 $10.00 11/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00 11/14/2017 Mechanical Permit Base Fee $25.00 11/14/2017 Park-Community SF $1,662.00 11/14/2017 Plumbing Permit Base Fee $25.00 11/14/2017 Plumbing Permit Fee(Enter Fixture Fee) $192.00 11/14/2017 Process ingrrech no logy Fee $25.00 11/14/2017 State Building Code Surcharge Fee $4.50 11/14/2017 Traffic Mitigation-City $3,355.00 11/14/2017 Water Heater $25.00 Total Due: $10,449.86 Total Paymcnt: $10,449.86 Balance Duc: 50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon I. OFFICE COPY I F SETBACKS NOTES. IINQNIA'R�TMEPA TH ST.INE B'WAJV NOWT 10' •BUILDING DIMENSYANS ARE TO __q&4SrDE 5' FA Cr a-Fa/NDAAOW PPROVED/ REAR 5' •6RADING 9YONN AS DE96W A07UAL LOCAAGW MAY VARY R. 3+00 •SLOW DRIVEWAY TO PUBLIC ROAD •m r finy 7O BE INSTALLED PER WA7EIP CITY OF ARL/NGTGW S STANDARD P7OLE O A Y' k S�FNl1• •St fENGll 70 BE INSTALLED OV pPAD/ENT WE OF BUILDING - . , 37 PVA1R�acZ AW tWp /r 7 0 BE ° ° d a 4 ° • ° ° n INSTALLED PER CITY OF ARL/NGTa S STANDARD.£ I • STORM NOTES.F • • e - - $ - - - - - - - - - •7ESC INSTALLED PR/AR To C WSNUCAON S7ARM GYEANOIUT. 20.00' •BARE Sacs COVERED N1A1 MULQY CONNECT Roar AND BW I 471 SF GYP ANO7H0?APPROVED BMP •MIRSaL PER WM6f BMP T513 - FOOANG DRAINS ORl1EWA+ • - - - - - (£fF 12-DEPTH) -! 7 T 500'PR/�A1E ALL GWS17E RUN6FF COINN£C7ED TO TOP 463.5 ° • I STpgM PR/VAX STLWM S7UB 1.7 TOE 461.;8 24 00 EAS�I/ENT 'NIF 9YALL BE STABILIZED PR/AR 1r �� I 70 BUILDING PEYPMIT BEING SE71MR ( k GARAX 10.010'PUBLIC f7NALlZED CLYVNECALW I BU/UNG I EA AW Y SITE NOTES: �+- + _ / '� 0YJklff I •770YRINE FOOTING DRAINS AND EXISTING - 1 q 'RO F ROOD DRAINS TO PERMANENT STARY DRAINAGE S676V POP �_�GLYVTOUR MR) g ril OVERHANG APPROVED PLAT ORA/NAGL�PLAN TOP 463.5 I J LOT 3 \ OV ALE NI7H 7HE CLVN7Y. 1.7.TOE 46 1.8 A'00 NI.E -AREA OF aS1URBANG�'INGYUDES A � P Y--2514 GARAGE LEFT SNARE LOT. to 00,WAUARNN I 1,67919r I LEGEND. EASEMENT _ 5.00'I m00 15Qp• �- &OW OFF ti ® WA7&MEU PAAO 12 Sig i i 4( ARE HYDRANT 1 AIR VAC \ I I 5� eft 5.00,BSYL 1.7 T�461.8 CATW BANN f1N19#D G1GW7gU4 I I O GYEANOUT 1 I (hp) I I MANHaf O=:C -D &OW WALL I � 7W REMOVAL I NI I N I I SCALE 1'=20' Q �,5 1J LOT 3 _ - - SITE PLAN \ + GREGOR Y PARK LGI HOMES PLAN NO. PALIX-2514 LOT AREA = 5,,773 SF DATE 912912017 PARCEL # LOT 3 HOUSE= 1,679 Sf Bellevue,W,,hi gt,,99007 DRIVEWAY= 471 SF DESIGNED CORE ADDRESS 9016 1681H Sr NE 425.995.7877 Fox 425.885.7963 WALKWAYIPAAO = 12 SF ��DESIGN PROJECT NUMBER TOTAL= 2,162 SF ENGINEERING PLANNING SURVEYING DRAWN CAF 13024L-GRG00 �s'�1'"!9�"�M1tA�!y1pM�►C�hM Permit Information Date 11/1/2017 Permit Number 1718 Project Name Gregory Park Applicant Name LGI Homes-Washington, LLC Applicant Address 9028 168th Street NE City,State,Zip Arlingotn,WA 98223 Contact Matt Adams Phone 425-785-0797 Email matt.adams@lgihomes.com Permit Type Single Family Residence Site Address 9016 168th Street NE Valuation 309450.70 Status Applied Permit Issued Permit Expires Square Feet 2894 Type of Construction/Occupancy Load V-B Number of Stories 2 Proposed Use New SFR Assigned To Kristin Foster Property Owner Parcel Address Legal Owner Phone Zoning 01166900000300 9016 168th Street LGI HOMES-WASHINGTON 111 Single Family Residence- NE LLC Detached Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type LGI Homes-Washington, 360-353- -abor and LLC Jake Jabusch D588 iake.jabusch@lgihomes.co CONTRACTOR Industries LGIHOHL857MB Review Date Type —bescr:iptionl Target Date Completed Date I Assigned To Status 11/1/2017 lResidential Dwelling 11/8/2017 [Amy Rusko In Review 11/1/2017 lResidential Dwelling 11/8/2017 JlKevin Olander In Review Fees Fee Description Notes Amount Building Permit Feel 322.10-00-001 $3,076.5 Building Plan Review Fe 345.83.00.00 $1,999.7 Furnace 322.10.00.001 $25.0 Gas Outlets Base Fee 1 to 51 322.10.00.001 $10.0 Mechanical Fee(Enter Fixture Fee)j 322.10.00.00 $25.0 Mechanical Permit Base Fee 322.10.00.00 $25.0 Park-Community SF 345.85.00.00 $1,662.0 Plumbing Permit Base Fe 322.10.00.00 $25.0 Plumbing Permit Fee(Enter Fixture Fee)j 322.10.00.0 16 $12 $192.00 Processing/Technology Feel 341.43.00.021 $25.00 State Building Code Surcharge Feel 386.00.0l.Og $4.50 Traffic Mitigation-Ci 345.85.00.021 $3,355.0 Water Heated 322.10.00.01 $25.00 Tota $10,449.861 Payments Date Paid By ount Descri tion I Payment T a Acce ted B 11/1/2017 IILGI Homes-Washington LLC $1,999.78 12heck#5710 Kristin Foster 11/1/2017 JILGI Homes-Washington LLC $8,450.08 ICheck#5711 Kristin Foster Total $10,449.86 Amount Outstanding:$0.0 Uploaded Files Upload File Date File Uploaded B 11/1/2017 12:38:09 PM 1718 Application. df Foster, Kristin x 11/1/2017 12:38:09 PM 1718 Site Plan.pdf Foster, Kristin x RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development O City of Arlington • 18204 59th Ave NE -Arlington,WA 98223 - Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Pro ect Address: 9016 168th Street NE Plat: Gregory Park Lot 3 j PI Single-family al Duplex ❑) Townhouse ❑ Addition Q. Accessory structure Proposed Area: 1' Floor. 1076 2" Floor: 1438 Garage: 380 Total SF: 2894 Describe Proposal (include cross street): Application for new single family residence to be located at 9016 168th Street NE. Cross street is 91st Valuation: Owner: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State:WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Applicant: LGI Homes - Washington LLC Address: 9028 168th Street NE City: Arlington State: WA Zip Code:98223 Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contractor: LGI Homes - Washington LLC Address: 9028 168th Street NE City:Arlington State:WA Zip Code:98223 _ Phone: 425-785-0797 Email: matt.adams@lgihomes.com Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019 I;��r�aivr�rl 6/16LP Page 1 of 3 .. �. �� �a. �� i M RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development �' Ov City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 N 'o Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) 6 Bath/Shower Combo (4.0) x 2 Mi Sink (1.5) x 1 [✓T Shower (2.0) x 1 Lei Lavatory (1.0) x 5 Ol Clothes Washer (4.0) x Water Closet(2.5) x 3 ek Dishwasher(1.5) x 1 Ek Water Heater x 1 Hose Bibb (2.5) x 2 Water Heater Model # ®� Other (list) x 1 AO Smith HPTU - 50N Plumbing Section Continued Proposed Water Piping Size: 3/411 Proposed DWV Material: ABS Proposed Piping Material: PEX Proposed DWV Size: 2" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6061-P Page 2 of 3 Y °�' RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: 21 Furnace (80+) Model# Bryant 915SA30040514 AFUE 95% Ell Heat Pump Model# SEER HSPE 01 AC Unit Model# SEER Ell Type II Hood ❑ Commercial Cooking Appliance 0 Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance 01 PV System Ol Fireplace Insert ❑l Outdoor BBQ 01 Storage Tank Freestanding Stove Gas Piping 1:11 Other Gas Piping Information Not Applicable: ai Black Steel Pipe Material: Pipe Size: 1 Total BTU's of all Appliances: 120,000 Distance from Meter to Furthest Appliance: _ • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: Print Applicants Name: 6/16LP Page 3 of 3 i Prescriptive Energy Code Compli a for All Climate Zones in Washington Project Information Contact Information Plan 2514 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R=Value U-Factor' Fenestration U-Factor" n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC n/a n/a Ceiling'` 491 0.026 Wood Frame Walig.m," 21 int 0.056 Mass Wall R-Value' 21/21" 0.056 Floor 30 0.029 Below Grade Wall' 10/15/21 int+TB 0.042 Slab--R-Value&Depth 10, 2 ft n/a 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1.Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. E2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑3.Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. J4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) is Efficient Building Envelope 1a 0.5 ❑ lb Efficient Building Envelope 1 b 1.0 ❑ 1c Efficient Building Envelope 1c 2.0 ❑ 1d Efficient Building Envelope 1d 0.5 ❑ 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑ 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 1.0 FA 1.0 3b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 3c 1.5 ❑ 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 P] 1.0 5a Efficient Water Heating 5a 0.5 0 0.5 5b Efficient Water Heating 5b 1.0 ❑ 1.0 5c Efficient Water Heating 5c 1.5 ❑ 5d Efficient Water Heating 5d 0.5 ❑ 6 IRenewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions iRece,ived fyj 31. 2017 VAF'/IrlPO I •fin' w�• � Table R402.1.1 Footnotes For 51: 1 foot.=304.8 mm,ci.=continuous insulation, int .=intermediate framing. a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. `"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall."10/15/21.+TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. C.There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. h Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. Reserved. m Int.(intermediate framing)denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section R402.1.3. Window, Skylight and Door Schedule Project Information Contact Information Plan 2514 Width Height Ref. U-factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door(24 sq. ft. max.) EH 0.0 0.00 Exempt Glazed Fenestration(15 sq.ft. max.) 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA Foyer 0.30 1 3 6 5 20.0 6.00 0.30 1 2 6 ° 17.8 5.33 Guest 0.30 1 3 5 15.0 4.50 Great Room 0.30 1 5 5 25.0 7.50 Dining 0.30 1 6 16 1D 1 41.0 12.30 Great Room 10.30 1 3 5 15.0 4.50 Master Bedroom 0.30 1 5 5 25.0 7.50 Stairs 0.30 1 2 2 4.0 1.20 Bedroom 2 0.30 1 3 5 15.0 4.50 Bedroom 3 0.30 1 5 1 15 25.01 7.50 Bonus Room 10.30 1 3 5 15.0 4.50 Bedroom 4 10.30 1 2 2 4.0 1.20 0.30 1 3 5 15.0 4.50 0.30 0.0 0.00 0.30 0.01 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.30 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 236.8 71.03 Vertical Fenestration Area Weighted U=UA/Area 0.30 Overhead Glazing(Skylights) Component Width Height Description Ref. U-factor Qt. Feet In' Feet Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 0.01 0.00 Sum of Overhead Glazing Area and UA 1 0.01 0.00 Overhead Glazing Area Weighted U=UA/Area 1 .00 Total Sum of Fenestration Area and UA (for heating system sizing calculations) 1 236.81 71.03 d Simple Heating System Size:Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington Stale Energy Code tWSECI and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0,30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at (360)956-2042 for assistance. f1ro bct Information Contact Information Plan 2514 Heating System Type: O All other systems O Heat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions Design Temperature Difference(AT) 47 AT=Indoor(70 degrees)-Outdoor Design Temp Area of Buildina Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 2.514 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 9.3 23,380 Glazina and Doors U-Factor X Area = UA Instructions 0.30 237 71.10 Skylights U-Factor X� �Area = UA Instructions 0.50 l ! Insulation Attic U-Factor X Area = UA Instructions R 59 0.026 1.513 39.34 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions ;,,Ica R Value No selection � -- Above Grade Walls(see Figure 1) U-Factor X Area UA Instructions R-21 Intermediate 0.056 2,670 149.52 Floors U-Factor X Area UA Instructions 0.029 1.513 43.88 ( R-30 1W Below Grade Walls(see Figure 1) U-Factor X i Area t UA Instructions No Below Grade Walls In this project. -- Slab Below Grade iseeFwum 11 F-Factor X Length UA Instructions No selection Select conditioning � —' Slab on Grade(see Figured F-Factor X Length UA Instructions 1 1111111 No Slab on Grade in this project. Location of Ducts Instructions Duct Leakage Coefficient `Conditioned Space. r' 1.00 Sum of UA 303.84 Envelope Heat Load 14,280 Btu I Hour Figure 1. Sumof UAXAT Air Leakage Heat Load 11,868 Btu I Hour VolumeX 0.6XATX.018 aMve tirade Building Design Heat Load 26,148 Btu I Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 26,148 Btu I Hour Ducts in unconditioned space:Sum of Budding Heat Loss X 1.10 Ducts in conditioned space:Sum of Budding Heat Loss X 1 Maximum Heat Equipment Output 36,607 Btu I Hour Budding and Duct Heat Loss X 140 for Forced Air Furnace Budding and Duct Pleat Loss X 1.25 for Heat Pump (071MV13) NASH&ASSOCIATES ARC F-1FFECTS PLAN 2 514 BEAM, LATERAL & SEISMIC CALCULATIONS i ..6 3Tfh_ (DA! " .OMAS NASH 'STATE QF WAS HINGTON Received OCT 312017 2015 IBC PX2111q? JULY 1, 2016 8003 118th AVE NE Kirkland, WA 98033 (426) 828-4117 WWW.NASH-ARCHITECTS.COM '� •.;r.• .t. I �- � � ..� _ NASHtASSOQ CLIENT:ATES BEAM DESIGN DATA PROJECT: I ARC ItITECTS DATE: NAME: Roof Loads: LL 25#/af DL 15 �Isf Total 40 Unless Noted Otherwise Floor Loads: LL 40#/sf DL 10 #/sf Total 50#/sf Deck Loads: LL 60#/sf DL 10 #/sf Total 70#/sf Soil• 1500 PSF Min, Concrete: Per MC 15 Masonry: Per IBC 15 Steel: Per IBC 15 Wood: Per IBC 15 Nailing: Per IBC 15 4" Beam: Douglas Fir #2 fv = 180 fb = 900 PSI E = 1,600,000 6" Beam: Douglas Fir #2 fv = 170 fb = 875 PSI E = 1,300.000 Joists & Hem Fir #2 Rafters: fv = 150 fb = 850 PSI E = 1,300,000 Glu—Lam Beams: fv = 240 PSI fb = 2,400 PSI (reduced by size factor, CF'KI) E = 1.800,000 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHrrECTS.COM PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 RB-1 Date: 10/24/16 Selection 4x 10 DF-L#2 Lu=0.0 Ft Condi ions NDS 2015 Min Bearing Area R1=3.4 inz R2=3.4 inZ (1.5)DL Defl= 0.02 in Data Beam Span 5.0 ft Reaction 1 LL 1313# Reaction 2 LL 1313# Beam Wt per ft 7.87# Reaction 1 TL 2120# Reaction 2 TL 2120# Bm Wt Included 39# Maximum V 2120# Max Moment 2650'# Max V(Reduced) 1466# TL Max Defl L/240 TL Actual Defl L 1>1000 LL Max Defl LOW W LL Actual Defl L/>1000 Attributes Section(in') Shear in') TL Defl(in) LL Defl Actual 49.91 32.38 0.04 0.02 Critical 29.44 12.22 0.25 0.17 Status OK OK OK OK Ratio 59% 38% 15% 12% Fb i Fv(psi) E(psi x mil Fc (psi) Values Reference Values 900 180 1.6 625 Adiusted Values 1080 180 1.6 625 Adiustments CF Size Factor 1.200 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL: 525 Uniform TL: 840 =A �- - Uniform Load A 0 - - - - - Z\ R1 =2120 R2=2120 SPAN=5FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 RB-2 Date: 10/24/16 Selection 4x 10 DF-L#2 Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=3.4 in2 R2= 3.4 in (1.5)DL Defl= 0.02 in Data Beam Span 5.0 ft Reaction 1 LL 1313# Reaction 2 LL 1313# Beam Wt per ft 7.87# Reaction 1 TL 2120# Reaction 2 TL 2120# Bm Wt Included 39# Maximum V 2120# Max Moment 2650'# Max V(Reduced) 1466# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max Defl L/360 LLActual Defl L/>1000 Attributes Section in' Shear(in') TL Defl(in) LL Defl Actual 49.91 32.38 0.04 0.02 Critical 29.44 12.22 0.25 0.17 Status OK OK OK OK Ratio 59% 38% 15% 12% Fb(psi) Fv(psi) E(psi x mil Fc- (psi) values Reference Values 900 180 1.6 625 Adjusted Values 1080 180 1.6 625 Adiustments CF Size Factor 1.200 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:525 Uniform TL: 840 =A Uniform Load A C _ z R 1 =2120 R2=2120 SPAN=5 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 B-1 Date: 10/24/16 Selection �3-11/8x 9 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=6.6 in' R2=6.6 in' (1 5)DL Defl= 0.06 in Recom Camber=0.10 in Data Beam Span 6.0 ft Reaction 1 LL 2775# Reaction 2 LL 2775# Beam Wt per ft 6.83# Reaction 1 TL 4281 # Reaction 2 TL 4281 # Bm Wt Included 41 # Maximum V 4281 # Max Moment 6421 '# Max V(Reduced) 3210# TL Max Defl L/240 TL Actual Defl L/504 LL Max Defl L/360 LL Actual Defl L/914 Attributes Section in') Shear(in') TL Defl(in) LL Defl Actual 42.19 28.13 0.14 0.08 Critical 32.10 20.06 0.30 0.20 Status OK OK OK OK Ratio 76% 71% 48% 39% _ Fb_U)si) Fv(psi) E(psi x mil) Fc L (psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adiustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:925 Uniform TL: 1420 =A Uniform Load A R1 =4281 R2=4281 SPAN=6 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 B-2 Date: 10/24/16 Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=5.6 in2 R2=2.6 in' (1.5)DL Defl= 0.02 in Recom Camber=0.03 in Data Beam Span 5.0 ft Reaction 1 LL 2423# Reaction 2 LL 1215# Beam Wt per ft 6.83# Reaction 1 TL 3666# Reaction 2 TL 1658# Bm Wt Included 34# Maximum V 3666# Max Moment 3013'# Max V(Reduced) 2633# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max Defl L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(in') TL Defl(in) LL Defl _ Actual 42.19 28.13 0.05 0.03 Critical 15.07 16.46 0.25 0.17 Status OK OK OK OK Ratio 36% 59% 19% 17% Fb(psi) Fv(psi) E(psi x mil Fc-L((si Ualues Reference Values 2400 240 1.8 650 Adiusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 1313 B=2120 1.0 885 H= 1370 0 1.0 360 1=450 1.0 5.0 I H Pt loads: R1 =3666 R2= 1658 SPAN=5FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 2514 BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622 GB-1 Date: 10/24/16 Selection 5-118x 19.1/2 GLB 24F-V4 DFIDF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1= 17.6 in2R2= 13.9 in (1.5)DL Defl= 0.19 in Recom Camber=0.28 in Data Beam Span 16.0 ft Reaction 1 LL 7544# Reaction 2 LL 6185# Beam Wt per ft 24.28# Reaction 1 TL 11440# Reaction 2 TL 9053# Bm Wt Included 389# Maximum V 11440# Max Moment 46400'# Max V(Reduced) 9093# TL Max Defl L/240 TL Actual Defl L/440 LL Max Defl L/360 LL Actual Defl L/769 Attributes Section in' Shear in' TL Defl in LL Defl Actual 324.80 99.94 0.44 0.25 Critical 237.01 56.83 0.80 0.53 Status OK OK OK OK Ratio 73% 57% 55% 47% Fb(psi) Fv psi) E(psi x mil) Fc l (psi) Values Reference Values 2400 240 1.8 650 Adiusted Values 2349 240 1.8 650 Adjustments Cv Volume 0.979 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 1313 B=2120 2.5 925 H= 1420 0 2.5 1313 C=2120 7.5 400 1=500 2.5 7.5 1838 D=2964 10.0 925 K= 1420 7.5 10.0 440 L= 550 10.0 16.0 F - I- LK I-I Pt loads: L LJ [C nD 0 R1 = 11440 R2=9053 SPAN=16FT Uniform and partial uniform loads are lbs per lineal ft. CLIENT`. _ -- NASH-ASSOCIATES WIND AND 5E15MIG DE516N DATA PROJECT' Ix c l I I T E c T s PER 2015 IBC DATE: NAME- WIND DESIGN GRITERIA DE516N PER ASCE 7-10 I. NOMINAL/ULTIMATE WIND SPEED V/asd /Vult 85/110 mph 2. RISK CATEGORY II 1.00 3. WIND EXPOSURE CATE60RY "B" 4. INTERNAL PRESSURE COEFFICENT +/-55 5. COMPONENTS AND CLADDING DESIGN PRESSURE +/- 16 psf BUILDINGS,STRUCTURES, AND PARTS THEREOF SHALL BE DESIGNED AND GONSTRUCTED IN ACCORDANCE WITH STRENGTH DE516N,LOAD,AND RESISTANCE FACTOR DESIGN, ALLOWABLE 5TRE55 DE516N,EMPIRICAL DESIGN OR CONVENTIONAL GON5TRUGTION METHODS, AS PERMITTED BY Tl-#E APPLICABLE MATERIAL GHAPTER, 5EGTION 1604.1 BUILDIN6-:15,5TR1JGTURE5, AND PARTS THEREOF,SHALL BE DE516NED TO WITHSTAND WIND LOAD5 AS DEFINED IN SECTION 16Oq AND ASGE "1-10 IMPLIFIED METHOD TO BE USED FOR WIND DESIGN PER ASGE-I-10,SECTION 27.5 (BUILDINO HEIGHT 15 LE55 THAN 160 FEET) 110 MPH ULTIMATE WIND SPEED U5E Iqb PSF PER TABLE 21.6.1 "EXPOSURE B" WOOD DESIGN PER SECTIONS 2304-2306.STRUCTURES U51N6 WOOD SHEAR WALLS AND DIAPHRAGM5 TO RE515T WIND,SEISMIC, AND ALL OTHER LATERAL LOADS SHALL BE DE5I6NED AND GONSTRUGTED IN AGGORDANGE WITH AF 4 PA SDPWS AND PROV151ONS OF SECTIONS 2305-2506 5E15MIG DE516N DATA DESIGN PER ASCE 7-10/SEGTION 1613 I. SEISMIC IMPORTANCE FACTOR le 1.00 2. SHORT PERIOD ACCELERATION 55 I.ibb "see footnote at bottom of pogo 3. 1 SECOND ACCELERATION 51 0.140 "see footnote at bottom of page 4.SITE CLASS D (default class per IBG) 5.SPECTRAL RESPONSE COEFFICENT 5„ O.G"12 '"see footnote at bottom of page 6. SPECTRAL RESPONSE COEFFICENT Su 0.-7116 *see footnote at bottom of page 'I. SEISMIC DESIGN CATEGORY D 8. SEISMIC FORGE RESISTING SYSTEM PLYWOOD SHEAR WALLS q. DE516N BASE SHEAR (see seismic calculations) 10. SEISMIC RESPONSE COEFFICENT Gs 0.15 11. RESPONSE MODIFICATION FACTOR R 6.5 12. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE 15. RISK CATE60RY II THE ANGHORA6E OF WALLS SUPPORTING GONSTRIIGTION SHALL BE BE DESIGNED IN ACCORDANCE WITH ASCE 7-10,5EGTION 12.I 2 IN STRUGTURE5 ASSIGNED TO SEISMIC DESIGN CATEGORY C-F,COLLECTOR ELEMENTS AND THEIR CONNECTIONS TO VERTICAL ELEMENTS SHALL 13E DESIGNED TO RESIST MAXIMUM EFFECTS AS SPECIFIED IN ASGE 7-10,SECTION 12.10.2.1 BASE SHEAR V= (F 5125/R) W ANCHOR BOLTS. 5/8" VIA X 10",A30-1 OR BETTER W/7" MIN. EMBEDMENT.V= 1104#/BOLT • PER U565,THE MAXIMUM Si IN THE STATE OF WASHIN6TON 15 0.748. ALL SEISMIC DESIGN VALUES USED IN THIS ANALYSIS ARE BASED UPON THIS NUMBER. SINGE 51 15 LESS THAN 0.75,THEN USE SEISMIC CATEGORY D IF R15K GATE60RY 15 I, 11,OR III 8003 11M AVE NE Kirkland, WA ID8033 (426) 828-4117 WWW.NASH—ARCHITECT'S.COM �9 a N ` -- - " i i 7 i pi , I P, TFI� Jill 1 , EE117F--7 .71 1= ❑ ❑ ❑ ❑ ❑ D ❑ DD 4 V) HH Mill �1111 V r _� o � tik N -� � � N S �� � k � � V S � � ❑ � N o '^ N V k N N -- -�N p C�v �r 9 ld �, -- .� ;� �S M -L 1 O LATERAL CALCULATIONS CLIENT: NASH k ASSOCIATES PROJECT: _ A;%( I I I I E c- I _ WIND WORKSHEET DATE:_ 85 MPH/110 MPH= NOMINALNLTIMATE WIND SPEED NAME: 19.b P5F I''RONT ELEVATION LEFT ELEVATION REAR ELEVATION RIGHT ELEVATION LOCATION TOTAL SHEAR FORCE (#) SHEAR UNIT SHEAR W z H z (see chart for wind pressure WALL SHEAR WALL 8 specified height) LENGTH (ft) (#/ft) TYPE l vP l7,Sxa k14t6 37 r v3 - - Z�P 3� z 39 ,5 ?r-f 3 7 3D 617- sK-1 14, 1 7 Z 44 (i?3- k� �•G ) f 3o 7 In �ZOk-T Zap Y 6 C Z/(?X 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHITECTS.COM _ 11 rIASHaASSOCIATES CLIENT: SEISMIC ANALYSIS PROJECT: AR(:f11`I'kCTc. DATE: NA�IE� 1 Weight of Building: Roof Assembly: Asphalt Shingles - 2.00#/ft Cedar Shakes - 2.25#/ft Tile - 9.50#/ft Felt - 0.15 #/ft Felt - 0.15 #/ft Felt - 0.15 #/ft 1/2" Plywood - 1.50 #/ft 1/2" Plywood - 1.50 Oft. 1/2" Plywood - 1.50 #/ft Trusses 0, 24" o.c. - 1.75 #/ft Trusses ® 24" o.c. - 1.76 #/ft Trusses 0 24" o.c. - 1.75 #/1t R-38 Insulation - 2.35#/ft R-30 Insulation - 2.25#/ft R-30 Insulation - 2.25#/ft 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2,00#/it 1/2" GWB Ceiling - 2.00#/ft Total 9.75#/it Total 9.90#/ft Total 17.90#/ft Use 10.00#/it Use 10.00#/it Use 18.00#/It let do 2nd Floor Assembly: Caret / Peed - 0.50#/it Hardwood - 2.50#/it 3/4' T&G Plywood - 2.50#/it 3/4" '1'&G Plywood - 2.50#/it 2x10 ® 16" o.c. - 2.30#/ft 2x10 cN 16" o.c. - 2.30#/it 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/it Total 7.30#/it Total 9.30#/it Use 10.00#/ft Use 10.00#/ft Interior Wall Assembly: Exterior Wall Assembly: 1/2" GWB - 2.00#/it 3/4" Wood Siding - 2,30#/it 2X4 ® 16" o.c. - 1.10 #/it 1/2" Plywood - 1.50 #/it 1/2" GWB - 2.00#/it 2x6 ® 16" o.c. - 1.37 #/ft Total 5.10 #/it R-21 Insulation - 2.10 #/it Use 8.00#/it 1/2" GWB - 2.00#/it Total 9.27#/it Use 10.00#/it 4" Brick Veneer - + 3.20#/ft 8003 118th AVE NE Kirkland, WA 9BO33 (425) 828-4117 WWW.NASH-ARCHITECTS.COM CLIENT: 77H=ASSOQATPS SEISMIC ANALYSISPROJECT: I I I r I C T S DATE: NAME: 2 SEISMIC: V = (C,) (Wdl) (Plywood) 2nd Level: Roof: or (Asphalt / Cedar Shake) 10#/ft X150 S- sf = J-31_� _ (Tile) 18#/ft X sf = _ Exterior Walls: L x 10#/sf x 1/2 (h) /&I X 10 k y Interior Walls: L x B#/sf x 1/2 (h) / �OX�, k TOTAL = Z&a 7 0 1st Level: Roof: (1st Floor Roof) 10#/ft X sf = 2nd Floor. 10#/ft X f sf = �� Exterior Walls: (E2) + L x 10#/sf x 1/2 (h) 6 goao - /(o Z k<O J-K, f 13 7 7 d - (E1) Interior Walls: (I o + L x 8#/sf x 1/2 (h) 5Lf (f0 f- QOK'Okq, TOTAL n Lf 7 3 vI -! 0 Basement: let Floor. 10#/ft X sf = Exterior Walls: (E1) + L x 10#/sf x 1/2 (h) Interior Walls: (I1) + L x 8#/sf x 1/2 (h) TOTAL _ 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WNW.NASH—ARCHITECTS.COMIL f - 1 CLIENT: NASH-ASSOCIATES SEISMIC ANALYSIS PROJECT: ARCHITECTS DATE:, NAME: 3 BASE SHEAR: BASE 5HEAR V= (F 5ps/W YV LEVEL 2: Wdl G!� I # x 0.149 = W/ O y LEVEL 1: Wdl 3(01 // # x 0.149 = S" Lf Z TOTAL:- Wdl (0 31 "/ _!I x 0.149 = 17' K 2 (V) Dead Load He' ht Moment Shear Stor Level Ix = [(Wdl)(h)TV Remarks (Wdl) (h� (Wdl)(h) (Wdl)(h) 2 N, S 37 36 3&KCq, c-17. 1 Z C�e o S� Total 6 31 CA 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH-ARCHITECTS.COM NASH&ASSOCIATES cisEN ARCHITEC"I-:; SEISMIC ANALYSIS PROJECT: DATE: NAME: 4 -- - x� cr 4. xzw zo N S N x x wM 0 knn w 07 ti x - — 0- M a N ? s �' s Z w o 4�- s pq zw .J N n. N N w - - .a .� 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 �� WWWWWW N�H�CH�F�CH�F�COM NASHtAss CLIENT: E(:'r S TEs SEISMIC ANALYSIS PROJECT`. x c r is DATE: NAME: Redundancy Factor (p): 1. Maximum allowable wall shear for p<=1 Vumax = (2)(Vaccstory)/Ab i/2 2. Maximum actual shear Vmax = Largest seismic wall shear 05 3. p = 2—[2(Vaccstory)/(Vumax)(Ab 1/2) Z 1 �C4c�1 Z �C1 o% 1D 0ONf 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW.NASH—ARCHITECTS.COM MM MiTek® MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA,95610 Telephone 916/676-1900 Re: 2514-FL Fax 916/676-1909 LGI HOMES 2514 FL The truss drawing(s)referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by BMC West-Everett, WA. Pages or sheets covered by this seal: R50499425 thru R50499441 My license renewal date for the state of Washington is May 16,2019. tip�gRRILL J T WASH 7 51398 w� o�e,�REGrs May 8,2017 Baxter, David IMPORTANT NOTE:Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, �per ANSI/TPI-1, Chapter 2. FA7 ` 1 1Loo ' - ti. •, . _ �� Job Truss Ti /pe Qty Ply LGI cS 2514 FL R50499426 2514-FL A2 Floor g 1 Job Reference loptiona0 BMC. EVERETT.WA 98205-3212 8.030 s Jan 23 2017 MITek Industries,Inc. Mon May 08 13:21:39 2017 Page 1 ID:mlgzTLjh7H1 sSQCFVTnR08zlaVJ-LWSaFxrw2TLk_wWKuFgvMotOgPhhgTdFD9a)d6zlYZA 0-1-6 HI 24.0 1 0-10A Scale=1:31.6 US= 3x4= 3x4 = 4x8 = A B C D E F G H I 0 rb P Le N M L K 3x6= 4x12 = 3x4= 4x12 = US= I 19.3-0 Plate Offsets(X,Y)— (A:Edge,0.0.12],IF:0-1-8,Edge) IM:0.1.8 Edgel [P:0-1-8 0-0.121 (Q:0.1.8 0.0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.73 Vert(LL) -0 33 M-N >686 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.99 Vert(CT) -0.49 M-N >470 360 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(CT) 0.09 J n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:77 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (lb/size) 0=1045/0-5-6,J=1045/0-2-10 FORCES. (lb)-Max Comp/Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-2894/0,C-D=-2894/0,D-E=356310,E-F=-3563/0,F-G=-2881/0,G-H=2881/0 BOT CHORD N-0=0/1719,M-N=0/3506,L-M=0/3563,K-L=0/3563,J-K=0/1714 WEBS B-0=-1951/0,B-N=0/1333,D-N=-695/0,D-M=262/428,H-J=1945/0,H-K=0/1325,G-K=-276/2,F-K=-912/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0.0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards R.R.LI,L a� o W, SJv. y� rd�o 51398� •�+�, aISTBR ssfONALti�� May 8,2017 -- --_— ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 110111.7473 rev.1010312015 BEFORE USE. f Doslgn valid far use only with MiTekiD conneclora This design is based only upon parameters shown,and Is for an individual building component,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly incorporate this design into the overall #+ T building design. Draong indicated is to prevmN bt"ing of individual buss web motor ohvfd rnombers only-AddAwrral te,nlwrary and penuanent txacing is always required for stability and to prevent collapse with possible personal Injury and pfoperty damage.For general guidance regarding the IV 11 1 r fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Carus r M CA 951it Jab , Truss Tn pro Dty JPWTLGH,0d S25t4PL 2514-FL A4 Floor 2 rence ttonal BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MlTek Industries.Inc. Mon May 0813:21:41 2017 Pape i ID:migzTyh7H1sSQCFVTnRO6zlaVJ-HJaKgdsAa4bSDDgi?gsNRDOOnDPk8OmYhT32y7z1Y2$ 0-1-8 H 74-0 — -1 - -i F1-3-0 OV-1-8 i Scale=t:zs.s 4x8= 3x4= 3x4= 4x6= 3x4 II 4x8 I I A B C D E F G H I J S 0 R P 0 N M L K 3x6 = 4x8= 3x4= 4x8= 5x8= 17�12 17.9--12 17-6-1 -3, Plate Offsets(X.Y)— rkEdoe,0-0-121.IF:0-1-8,Edge1.fJ:G-3.0.Edgel.(0:0-1-8.Edael.IR:0-1-8.0-0-121.I5:0.1-8,0-0-121 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1,00 TC 0.51 Vert(LL) -0.24 O-P >883 360 MT20 185/148 TCDL 10.0 Lumber COL 1.00 BC 0.88 Vert(CT) -0.35 O-P >597 240 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(CT) 0.01 J n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:76lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No 2(flat) except end verticals WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) J=952/0-2-14,Q=952/0-5-6 FORCES. (lb)-Max-Comp'Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-2549)0,C-D=-2549/0,D-E=2884/0,E-F=-2884/0,F-G=-2515/0,G-H=2515/0,H-1=811/0,I-J=-814/0 BOT CHORD P-Q=0/1546,O-P=0/2988,N-0=0/2884,M-N=0/2884,L-M=0/1541 WEBS J-L=0/1176.B-Q=-1755/0,B-P=0/1137,D-P=-498/0,D-0=340/240,H-L=-105710,H-M=0/1106,F-M=-66010 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to Increase plate sizes to account for these factors. 3)All plates are 1-50 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J. 5)Recommend 2x6 strongbacks,on edge,spaced at 10.0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7)CAUTION,Do not erect truss backwards. J� o�wastej, 0 r ��► ,p 51398 'r �,c� �crsTSR1� sStoNaL�'�' May 8,2017 WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. Design valid for use only with MITekO connectors.This dosign is based only upon parameters shown,and Is for an Individual building componenl,flat a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ---building destyn.Brachty lnditaledis loWavwu lwchliny u1 nlWvidunl lava web nudlm ulmid uwmLeu udy-AJJ41ww1 lamywioyand pumrananl Uacsiy R��'.et. is always requeed for stability and to prevent collapse with possible personal injury and property damage.For general guidance regaroing the 1� a fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSBA9 and BCSI Building Component 77T7 Greenback Lane Safety Infomtatlon available from Truss Plate Insldule.218 N Lee Street,Suite 312.Alexandria,VA 22314. Suds 109 G nrs H his CA 10 Job Truss Tn de pl=IPIYLGI�11 o 2514 FLR50499429 2514-FL A5 FLOOR 3eference optional BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:42 2017 Page 1 0-1-8ID:migzTLjh7HlSSQCFVTnRO6zlaVJ-mV8jtztpLOJJrNFvZNNc Rwaidjltgztw7ocUR2JYZ7 H i 2.6.0 1-3-0 01jr8 Scale=T:29.o 4x8= 3x4= 3x4= 48 = A B C D E F G H I p —::At u5 P N M L K 3x6= 48= 3x4 = 4x8= 3x6= 17-9-12 Plate Offsets(X,Y)— (A:Edae.O-0.12) [F:0-1-8 Edgel IM:0-1-8 Edoel fP•O.1-8 0.0-121 (Q:0 1-8 0-0 12) IR:0-1-8 0-0-12] IS:0 1-8 0-0-12) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.56 Vert(L-) -0 25 M-N >826 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.90 Vert(CT) -0.37 M-N >558 360 BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(CT) 0.07 J n/a nla BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:73 lb FT=O%F,12%E LUMBER- ` BRACING- TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No 2(flat) except end verticals. WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 0=959/0-5-6,J=959/0-3-6 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=2574/0,C-D=2574/0,D-E=2926/0,E-F=-2926/0,F-G=2547/0.G-H=2547/0 BOT CHORD N-0=0/1560,M-N=0/3026,L-M=0/2926,K-L=0/2926,J-K=011558 WEBS B•O=-1770/0,B-N=011152,D-N=-513/0,0-M=-340/251.H-J=-1768/0,H•K=0/1122,F-K=-672I0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �ERRILL 9 .off 51398 �L'GISTSR� 4' SSror,AL��o May 8,2017 WARNING•Vofify design pammefors and READ NOTES ON TMS AND INCLUDED WTEK REFERENCE PAGE NIP7473 rev.10l03/2015 BEFORE USE. Design valid for use only with MiTeg19 connectors.This design Is based only upon Parameters shown,and is for an individual building component.not d truss system.Before use,the budding designer must verity the applUbdity of design parameters and Property incorporate this design into Iho overall budding design Bracing 1ndical ed is to prevent buclaing of individual truss web andlOr Chord members only Additional temporary and permanent bracing w Ag�v rd> -- is always required for stability and to prevent collapse will,possible personal injury and Property damage_For general guidance regarding the AY8 EE EE fabrication,storage,delivery.erection and bracing of trusses and truss systems,see ANSVTPH Quality Criteria,OSB•89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute.21S N.Lee Street,Suite 312,Aloxandda,VA 22314. Suite 109 I--H t Ms CA 956 10 Job Truss Tn re Qty Ply LGI h S 2514 FL R50499430 2514-FL A6 GABLE 1 1 Job Reference(optional) BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:43 2017 Page 1 ID:migzTLjh7H1 sSQCFV rnR06zlaVJ-Ehi55JuR6irASXg575urWeTgsOHicMWr8nY90tzlYZ6 0*8 011(8 Scale=1:28.6 A B C D E F G H I J V X a m U W T S R Q P O N M L K 2-0•D 4.0-0 8-0-0 10-0-01t I 16 0 0 17 9 12 2-0.0 2.0-0 2.0 0 2-0.0 2.0.0 2-0-0 2 0(1 2-0-0 1 9 12 Plate Offsets(X,Y)— fkEdae 0-0-121 (U:0-1-8 0.0-121 IV'0-1-8 0.0-121 IW0-1-8 0.0-121 fX'0.1-8 0-0-121 LOADING (psfj SPACING- 2-0-0 CSI. DEFL. in (lac) Ildefl Lld PLATES GRIP TCLL 40 0 Plate Grip DOL 1.00 TC 0.15 Vert(LL) n/a n/a 999 MT20 185/148 TCDL 100 Lumber DOL 1.00 BC 0.02 Vert(CT) n/a n/a 999 BCLL 0 0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 K n/a n/a BCDL 5.0 Code IRC2015fTP12014 Matrix-R Weight:58 lb FT=0%F,12%E LUMBER- BRACING. TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No 2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing OTHERS 2x4 HF No.2(flat) REACTIONS. All bearings 17-9-12 (lb)- Max Grav All reactions 250 Ib or less at joint(s)T,K,S,R,Q.P.0,N,M,L FORCES. (lb)-Max Comp./Max.Ten -All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 5)Gable studs Spaced at 2-0-0 cc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �RRILL 8 J19 �F WASI9�{j, yd�� 51398 +t' GISTEn" �sSfdNAL �G May 8,2017 AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the budding designer must verify the applicability of design parameters and properly incorporato this design into the overaa —-tanlding design bracing mdicateo r4 to prevent oualdrng of mdrvTdual truss web and/or camore members only. Additional temporary and permanent bracing - ---- 11 'Tp 1� is aAva sq uired q .� uired for stability and to prevent collapse with possible personal Injury and prop"damage. For general guidance regarding the rV ly 1 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSUTPI1 Quality Criteria,DSBA9 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria.VA 22314, Suite 109 roses' s 9 f Job •7 Truss Tn. pe Qty 'Ply LGI i _S 25141-L 2514-FL 61 GABLE 1 1 ]— — 1Job R R50499431eference(optional) BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MTek Industries,Inc. Mon May OB 13:21:44 2017 Page 1 ID:migzTLjh7H1 sSQCFVTnRO6zlaVJ-iuGTlfu3t?z14hPHhoQ43s0?VQdnLpm_NRHiYJzIYZ5 0*8 Scale=1:33 2 3x6 FP= A B C D E F G H I J K L M AA Z Y X W V U T S R Q P O N 3x6 FP= -121 7.8-72 4 8-12 �_ �8-12 8 8.72 { 10.8.12 I 12-8-12 14 8-12 78 8 12 JIM2 20 B 8 08-t2 2-0-0 ZO.O2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 11112 Plate Offsets(X Y)— fA.Edae.0.0-121 (AA:0-1-8,0-0-121,fAB:0-1-8 0-0-121 LOADING (pso SPACING- 2-0.0 CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP TCLL 400 Plate Grip DOL 100 TC 0.16 Verl n/a n/a 999 MT20 185/148 TCDL 100 Lumber DOL 1.00 BC 0.03 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 N n/a n/a BCDL 50 Code IRC2015/TPI2014 Matrix-R Weight:67lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2(flat) REACTIONS. All bearings 20-7-0. (lb)- Max Grav All reactions 250 Ib or less at joint(s)Z,N,Y,X,V,U,T,S,R,Q,P.O FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1 5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 5)Gable Studs spaced at 2-0.0 oc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. �,RRIL.�8q a� WAS 7� i r°� R 51398 �'r �A AGIST6K" �ss70NAL � May 8,2017 �,WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI/-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MITaKD connectors This design is based only upon parameters shown,and is for an individual ba8ding component,not a truss systam.Before use,the braid"designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web a",iif chord members only.Additional temporary and permanent bracing is always required for stability and to proven)collapse with possible personal injury and property damage. For general guidance regarding the 1191, fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPl1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria.VA 22314. Suite 109 1 s 958f0 Job .. Truss Tn de pry Ply Cal _S 2514 FL R50499432 2514-FL 82 Floor 5 1 Job Reference(optional) BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:45 2017 Page 1 ID:n*zTLjh7HISSQCFVTnR06zlaVJ-A4prWivheJSuir TEVxJb3Y4SgoB4AZ8c51G5mziYZ4 'tea r 1-3-0 , 1^ 0*8 Scale=1:33.8 4x8= 3x6= 3x4= 3x6 FP= 48 = A B C D E F G H I J K To S 3x10 = O P O N M 3x6 FP= 3x4= 3x4= 412 = 3x6= 4x12= L 2"-8 20" Plate Offsets(X.Y)— fA:Edoe 0-0.121 (N:0-1-8 Edgel f0:0-1-8 Edael (S:0-1-8 OA-121 IT:0-1-8 0.0 121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Weill Ud PLATES GRIP TCLL 400 Plate Grip DOL 1.00 TC 0.53 Vert(LL) -0.35 M-N >700 480 MT20 1851148 TCDL 100 Lumber DOL 1.00 BC 072 Vert(CT) -0.50 M-N >492 360 BCLL 0 0 Rep Stress Incr YES WB 044 Horz(CT) 0.09 L nla n/a BCDL 50 Code IRC2015/TPI2014 Matrix-R Weight:89 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat)*Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, A-I:2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr(flat) except end verticals. BOT CHORD 2x4 HF No.2(flat)"Except" BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. L-Q:2x4 DF 180OF 1.6E or 2x4 DF No 1&Btr(flat) WEBS 2x4 HF No.2(flat) REACTIONS. (lb/size) L=1125/0-5-6,R=1125/0-2-10 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-3190/0,C-D=-3190/0,D-E=4170/0,E-F=-4170/0,F-G=-4170/0,G-H=319210, H-J=3192/0 BOT CHORD P-R=0/1861,O-P=0/3946,N-0=0/4170,M-N=0/3952,L-M=0/1868 WEBS J-L=-2120/0,B-R=-2112/0,J-M=0/1502,B-P=0/1508,C-P=-261/0,GM=-863/0, D-P=-857/0,G-N=-158/586,0-0=108/612,E-0=-326/38 NOTES- 1)Unbalanced floor live loads have been considered forthis design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1 5x4 MT20 unless otherwise indicated. 4)ProvAe mechanical connection(by others)of truss to bearing plate at joint(s)R. 5)Recommend 2x6 sli ongbacks,on edge,spaced at 10.0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. CEO wO� R 51398 Eq �.-I FQts i SK" Assf�NALE�G May 8,2017 MONVIRMSM ,j WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 114II-7473 rev.1010312015 BEFORE USE. • Design valid for use only with MIT06 connectors.TNs design Is based only upon parameters shown,and is for an vidlviduat budding component,not a truss system Before use,Ute budding designer must verify the appilcabibty,of design parameters and pfopedy Incorporate this design into the overall p� ----building design.tlracing indicated is to prevent ouekhng or individual truss web and/or chord members only.Additional temporary and parmanenf bracing I�ii1T9!< is always required for stability and to prevent collapse with possible personal injury and property damage For ganafai guidance regarding the fabrication,storage,dal"ry,erection and bradng of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information avadable from Truss Plate Insldtde,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 C us CA 95810 Job ,r Truss Tr. ?e Qty Ply LGI 1 Reference S 2574 FL o tionie R50499433 2514-FL B3 floor 5 1 Job BMC, EVERETT,WA 98205-3212 a.030 s Jan 23 2017 MITsk Indusldes.Inc. Mon May 08 13:21:46 2017 Page 1 ID:migzTLjh7HlMCFVTnR06zlaVJ-e NDjKwJPdDIJ_YgoDSY8H5EPE8ypcgHglmpdCzIYZ3 ' 2-6-0 1-3-0 1-1-2 1r-8-14 _" Scale=1:37 5 4x8= 3x6 FP= 3x4= 3x6 = 4x12= 3x4 11 3x4= A B C D E F G H I J K L V o U T S R Q P 0 N M 3x6 = 4x12 = 3x4= 3x4= 3x6 FP= 4x12 = 4x12= 7- 2 10 20.7-2 0• •8 1.11.14 Plate Offsets(X Y)— fA:Edge 0-0-121 [L 0-I-8 Edcel [Q 0-1-8 Edge,[R:0.1-8 Edgej,fU 0.1-8 0.0-121 [V:0-1.8 0-0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.58 Vert(LL) -0 36 P-Q >688 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 075 Vert(CT) -0.48 P-Q >513 360 BCLL 0.0 Rep Stress Incr NO WB 045 Horz(CT) 0.08 N n/a n/a BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:99 lb FT=0%F,12%E LUMBER- BRACING- TOP CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr(flat)"Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, A-D:2x4 HF No 2(flat) except end verticals BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr(flat)"Except' BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. M-0:2x4 HF No.2(flat) WEBS 2x4 HF No.2(flat) REACTIONS. (lb/size) T=1087/0-2-10,N=1711/0-5-8 Max Grav T=1104(LC 3),N=1711(LC 1) FORCES. (lb)-Max.Comp/Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-3108/0,C-E=-3108/0,E-F=-4021/0,F-G=4021/0,G-H=-4021/0,H-1=-2949/0, I-J=-2949/0,J-K=0/555,K-L=0/552 BOT CHORD S-T=0/1823,R-S=0/3828,Q-R=0/4021,P-Q=0/3751,N-P=0/1582 WEBS K-N=-265/0,B-T=2069/0,B-S=0/1459,C-S=-256/0,J-N=-2165/0,J-P=0/1591, H-P=-944/0,1­1-0=98/668,E-S=817/0,E-R=-171/569,F-R=-302171,L•N=-677I0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1 5x4 MT20 unless otherwise indicated. 4)Provide mechanical connection(by others)of truss to gearing plate at joint(s)T. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard O�L 8 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=l 00 J OF Uniform Loads(plf) Vert:M-T=-10,A-L=-100 Concentrated Loads(lb) Vert:L=-328 51398 Ar AL S' May 8,2017 WARNING-Varrry design parameters and READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE Afll-7473 raw.10/0312015 BEFORE USE. • Design valid for use only with WWI)connectors This design rs based only upon parameters shown,and is for an individual building component,not a lass system.Before use,the building designer must venry the appllcabrllty or design parameters and property Incorporate this design Into the overall budding aeaign.Bracing indicated td to prevent buckling of mdMdual truss web anoror chord members only, Additional temporary and ponuanum teaunry 'A/+i'1"v��' Is always required for stability and to prevent collapse with possible personal Injury and property damage For general guidance regarding the 7�! 1 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSlrTPll Quality Criteria.DSe-89 and SCSI Building Component 77T7 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Loe Street Suite 312,Alexandra,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Tr1 pe Qty Ply LGI t .S 2514 FL R50499434 2514-FL C1 Floor 3 1 Job Reference(Optional) BMC, EVERETT,WA 98805-3212 8.030 s Jan 23 2017 MITek Industries,Inc. Mon May 08 13:21:47 2017 Page 1 ID:migzTLjh7H 1 sSQCFVTnRO6zlaVJ-6SxcwgxxAwLcx87sMwznhUdUteYpY7UQ3P WN9ezIYZ2 0-1-8 r 1�.9 1`rrtr —2&-0 I 0-qA 0.1.Si„1"1-8 Scale=1:23 3 15x4 II 46 II 3x4 11 3x4= 1.5x4 II 3x4= 3x4 11 06 II A B C DE F G H 0 A N M L K3x4= J I 1.5x4 II 4x6= 3x4= 46= 1 5x4 11 01 2 .4 1 4 13.0 0. -8 Plate Offsets KY)— (A:0-3.0.Edgel (H:0-3-O.Edgel (K:0.1-8 Edael (LU-1.8 Edge] LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 028 Vert(LL) -0.07 L >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 100 BC 0.46 Vert(CT) -0.11 L-M >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(CT) -0.02 H n/a n/a BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:59lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) A=709/0-1-8,H=709/0-1-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-8=632/0,B-C=-631/0,C-D=1709/0,D-E=-1709/0,E-F=1709/0,F-G=-631/0,G-H=-632/0 BOT CHORD L-M=0/1413,K-L=0/1709,J-K=0/1413 WEBS A-M=0/915,H-J=0/915,F-J=-887/0,C-M=887/0,F-K=0/416,C-L=0/416 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A,H. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. ORRILL WAS.y„ SI�NAL�� May 8,2017 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design Is based only upon parameters shown,and is for an individual building component,not a truss system Before use,the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall - - building design.Bracing Indicated is to prevent buckling or individual truss web and/or chord members only.Additional temporary and Permanent bracing - _—-- —6V 9 iTek'- Is always required for stability and to prevent collapse w;lh possible personal injury and property damage. For general guidance regarding the r ! 3 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSVTPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,219 M Lee Street.Sude 312,Alexandra,VA 22314. Suite ID9 Citrus Hiliatits,CA 95610 Job s ]Truss Ti pe Tty Ply LGI :S 2514 FL R50499435C2 Floor 1 Job Reference o U OMC, EVERETT.WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:47 2017 Page 1 ID:migzTLjh7H1 sSQCFVTnR06zlaVJ-6SxcwgxxAwLcx87sMwznhUdTReaZY81Q3PWN9ezIYZ2 0-3-0 i 1-1-81 I-� i 2-6-0� i 1-1-6 0 tale=1:15.5 3x6 II 3x4 II 3x4= 1.5x4 II A 8 C D 3x4= E L 1.5x4= 0 b 1 5x4= K J 3x6 1 H G F 1 5x4 11 1 5x4 11 1,5x4 I I 3x4 = 0 3 01 U-14 0-3 0 7.11.14 Plate Offsets(X,Y)-- (C:0-1-8.Edgel.(0:0-1-8 Edgel.fJ:Edae 0-0-121 (K:0-1-8 0^0-12) (L:0-1.8 0.0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL) -0 05 H-I >999 480 MT20 185/148 TCDL 10-0 Lumber DOL 1.00 BC 0.35 Vert(CT) -0.06 H-I >999 360 BCLL 0-0 Rep Stress Incr YES WE 0.14 Horz(CT) -0.01 F n/a n/a BCDL 5-0 Code IRC2015(TPI2014 Matrix-R Weight:37lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No 2(flat) except end verticals. WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) A=426/0-2-14,F=426/0-3-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD A-B=383/0,B-C=-383/0,C-D=-601/0 BOT CHORD H-1=0/601,G-H=0/601,F-G=0/601 WEBS B-1=269/0,A-1=0/555,D-F=-678/0,C-1=-281/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0,131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0 500in. 6)CAUTION,Do not erect truss backwards. to 51398 sSt�NALE�� May 8,2017 J,WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1-7473 rev.1010312015 BEFORE USE. Design valid for use only with MITek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system Before use,the butlding designer must verily the applicability of desgn parameters and properly incorporate this design into the Overall buBQn Ms yn. Bracing indicated fa foptdGoni'bock buckling oilndiv-dudl rc^wdbbndrOi cFrTmdbar-d oNy.Atldpiondf lemporaiy-e-nd permaned ftirbcing - 7l;elTA l�� is always required for slabikty, V!and to prevent collapse with possible personal intury and property damage For general guidance regarding the Y 1 1 t fabrication.storage,delivery,erection and bracing of trusses and truss systems,see ANSVTPII quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N,tee Street.Sude 312,Alen ridan,VA 22314- Suits tog Heights CA 95610 Job s Truss R50499436 TFI'oo, pe City Ply LGI S 2514 FL 2514-FL D1 3 1 Job Reference tional BMC. EVERETT.WA 98205-3212 8.0W S Jan 23 2017 MITek Industries,Inc. Mon May 08 13:21:48 2017 Page 1 ID:nftzTLjh7H1sSQCFVTnR08ziaVJ-aN 8oyZwETSZii2weUODiAepiwnHbyal3Fwh5ziYZ1 if! 7.6.00 I 1-5-19 � 1-3-0� 0 6 Sc ate 1:25 5 1.5x4 II 1,5x4= 3x6 II 3x4 II 3x4 = 3x4 11 3x4= 1 5x4 11 3x4= 1.5x4= A B C D Q E F G H P cab � 0 N M K J3x4= I 1.5x4 II 3x6 = 3x6= 1 5x4 II 3x4= 4-1 -12 0 1� 8.7 10 18 2-10 1 Plate Offsets(X,Y)— fE:0-1-8.Edoe1,fJ:0.1-8.Edgel f0:0-1.8 OA-121 RG-1-8 0-0-121 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (too) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.33 Vert(LL) -0.05 I-J >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.28 Vert(CT) -0.08 I-J >999 360 BCLL 0 0 Rep Stress Incr YES WB 0.14 Horz(CT) 0.01 1 n/a n/a BCDL 5,0 Code IRC2015ITP12014 Matrix-R Weight:64lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. (lb/size) A=346/0-1-8,L=818/0-5-8,1=443/0-3-7 Max Grav A=395(LC 8),L=818(LC 1),1=446(LC 8) FORCES. (lb)-Max.Comp./Max Ten -All forces 250(lb)or less except when shown. TOP CHORD A-8=-346/0,B-C=-34410,E-F=-63710,F-G=-637/0 BOT CHORD L-M=0/550,K-L=0/637,J-K=0/637,I-J=0/603 WEBS A-M=0/499,D-L=-274/0,C-L=-517/0,G-1=684/0,E-L=-689/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0 500in. 6)CAUTION,Do not erect truss backwards. -RRIL. 8 ti� ox 43 NAL May 8,2017 ,C\WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MIT00 connectors This design is based only upon parameters shown,and Is for an individual building component,not a truss system.Before use,the building designer must very the applicability of design parameters and property incorporate this design into the overall MR, budding dosign. Nrarnrg indicated rs to prevent bucks"of Individual truss web and/or chord members only Additional temporary and permanent bracing 1•��i7e�{is always required for stability and to prevent collapse with possible personal Iniury and property damage.For general guidance regarding the p fabrication.storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPI11 Quality Criteria,OSS-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate InstNule,216 N.Lee Street,Suite 312.Alexandria,VA 22314. Stale 109 Citrus Holonl.,CA 956 to r rJob Truss Ti /pe Qty, Ply LGI cS 2514 FL 2514-FL D3 F100T 5 1 R50499437 Job Reference(optional) BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:50 2017 Page 1 ID:migzTLjh7H1 sSQCFVTnR06zlaVJ-X1 dkZizgSdAocsR13WU17FuNrR5lTstINkl mzzlYZ? 0-1-8 e HI 2-6-0 ,i 1-0-14 I�3-0 1i B-14 0����,,==�8 Scale 1MA 3x4= 3x4= 3x4 11 4x6= 3x4 = 3x8 FP= 3x6= A B C D E F G H I J K X o m lu S RQ 0 N M 3x4= 3x6 FP= 3x10= 3x6= 3x10= 3x6= 5 5$ 20.5-4 5-" 14-11-14 Plate OHsels(X,Y)-- fA:Edue,0-0-121 18:0-1-8 Edgel fC0-1-8 Edael fG:0-1-8 Edge] fO:0-1-8 Edgel lU'0-1-8 0-0-121 fV'0-1-8 0.0.121 Mho 1 8 0-0.121 fX'0-1 8 0-0.12) LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.71 Vert(LL) -0.25 M-N >716 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 1.00 Verl(CT) -0.32 M-N >561 360 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(CT) 0.04 L n/a n/a BCDL 5.0 Code IRC2015rrPI2014 Matrix-R Weight:84 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No,2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No.2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (lb/size) L=801/0-5-6,T=258/0-3-6,P=1148/0-3-8 Max Grav L=805(LC 7),T=333(LC 10),P=1148(LC 1) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD B-C=-380/62,E-F=-2057/0,F-G=-2057/0,G-H=-2024/0,H-J=-2024/0 BOT CHORD S-T=-621380,R-S=-62/380,P-R=-62/380,O-P=0/1228,N-0=0/2057,M-N=0/2057, L-M=0/1269 WEBS B-T=-429/70,C-13=492/0,E-P=-1483/0,E-0=0/992,F-0=-337/0,J-L=-1440/0, J-M=0/857,H-M=-32010,G-M=-294/128 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3)All plates are 1.5x4 MT20 unless otherwise indicated. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Old(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. J�9 aF WAS�'�F�, a0A Y0� 51398 cq� S'rr�NAL��G May 8,2017 WARNING.Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.1010312015 BEFORE USE. Design valid for use only with UlTek®connectors-This design Is based only upon parameters snown,and is for an Individual building component,nol �. a truss system.Before use,the building designer must verify the applicability or design parameters and property incorporate this design into the ovetall -twA0ing design.!!racing indicated is to prevent buckling or individual uusswoo and/or chord members only.Additional temporary and permanent bracing - MITek` is always required for stab6hy and to prevent collapse with possible personal injury and property damage For general guidance regarding the 1 7 R fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312,Alexandria,VA 22314. Suite 109 C s i t A 9 10 IJob 1 Truss Tt pe pry Ply LGI :S 2514 FL R50499438 2514-FL D4 GABLE 1 1 Job Reference o tional 1111MC. EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 0813:21:51 2017 Page 1 ID:migzTLjh7H1 sSQCFVTnRO6zlaVJ-?EB6m2_SD9rl QmRdbm2jrKoCeFOGU_UO_l UalPzlYZ_ 0*8 0*8 Scale=1:33.6 3x6 FP= 2x4 I I A B C D E F G H I J K L M AC o Z AB C'LZ:1 a:l::�Z X X X X y� Y X W V U T S R Q P 0 N 3x6 = 3x6 FP= c-" 4 8 2•fr8 4-5.8 B-SS 8.5-8 f0•s•8 12.5.8 14•S-8 IB•5.8 8.5.8 20.5.4 0-•8 2-0-0 2-0.0 21-:0 2-0-0 2-0-0 2-0-0 2. . 2-0-0 2-0-0 1-11-12 0.40 Plate Offsets(X,Y)— fA:Edoe 0 0 121 fM:O 1-8 Edgei fZ 0 1 8 0 0 1 J,(AA:0-1-8,0-0-121.fAB:0-1-8.0.0.121 fAC:O-1 8 0-0-121 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.16 Vert(LL) nla n/a 999 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.04 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 N n/a n/a BCDL 5.0 Code IRC2015lrP12014 Matrix-R Weight:67 lb FT=O%F,12%E LUMBER- BRACING- TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural woad sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 HF No-2(flat) except end verticals. WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing OTHERS 2x4 HF No,2(flat) REACTIONS. All bearings 20-2-4. (lb)- Max Grav All reactions 250 Ib or less at joint(s)Y,N,X,V,U,T,S,R,Q,P,O FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions, It is the responsibility of the fabricator to increase plate sizes to account for these factors. 2)All plates are 1.5x4 MT20 unless otherwise indicated. 3)Gable requires continuous bottom chord bearing. 4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 5)Gable studs spaced at 2-0-0 oc. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Z 6 X 51398 Sf�NAL May 8,2017 WARNING-Verlry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MITek®connectors.This design is based only upon parameters shown,and Is for an individual busking component.not a truss system.Before use,the building designer must very the applicability of design parameters and property incorporate this design Into the overall bwiO4 deslgn.Bracing indkated is 10 vfe—it Lucmloq of indivwwj buss web dudNr Jwrd mumrbma ,Ay.AdJitiowl lrniywary euU veuevrwnl breulny lA AL���� is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the t V 11 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSVMI Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alemndds,VA 22314. Sulu 109 Cfts Heights,CA 95610 Job a Truss T. /pe Qry Piy LGI =S 2514 FL 2514-FL F1 FLOOR GIRDER �99439 1 2 Job Reference o tional BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek industries,Inc. Mon May 0813:21:51 2017 Page 1 ID:ini9zTLIh7HI SSQCFVTnRO6zlaVJ-4EB6m2 SD9flOmRdbm2JrKo8PFyhUxRO 1UalPz1Y2_ r ?-11.3 s I Scale:V=1' A 45 I F B 3x4= C4x5 II a 16 3x4= 3x4 = 6 1-14 B 5$ 0 3� Plate Offsets(X,Y)— fC:Edoe,0.3-81 8-1-14 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.43 Vert(LL) 0.00 D-E >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.27 Vert(CT) -0.00 D-E >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.22 Horz(CT) 0.01 D n/a n/a BCDL 5.0 Code IRC2015lrP12014 Matrix-R Weight:53 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 DF 160OF 1.6E or 2x4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr except end verticals. WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) E=1529/0-5-8,D=1855/0-11-14 FORCES. (lb)-Max Comp/Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-E=-450/0,C-D=-783/0,A-B=-28410,B-C=-304/0 BOT CHORD D-E=0/2979 WEBS B-E=-2891/0,B-D=-2870/0 NOTES- 1)2-ply truss to be connected together with 10d(0 131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-9-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to Increase plate sizes to account for these factors. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) RRIi j Vert:D-E=10,A-F=-100,C-F=527 v WA Concentrated Loads(lb) J p� Vert:F=-1034 ( C� ace O vo�+ 51398-�q sy� S4 j AL1nyG May 8,2017 ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111I1.7473 rev.1010312015 BEFORE USE. Design valid for wa only with AhlTekD connectors_This design Is based only upon parameters shown,and Is for an Individual budding component,not a truss system.Before use,the budding designer must verify the applicability of design Parameters and property incorporate this dasyn into the overall oudaing design.Hraong indicated is to prevent buckling of individual truss web andtor chord members only.Additional temporary and permanent bracing a CT�ek�-IF — Is always required for stability and to prevent collapse with possible personal Injury and property damage.For general guidance regarding the M fabrication.storage,delivery,erection and bracing of trusses and buss systems,see ANSVTPII Quality Criteria.OSO.89 and SCSI Building Component T777 Greenback Lane Safety Information available from Truss Plato Instituto,218 N,lee Street,Suite 312,Alexandria,VA22314. Suite 109 Citrus H i his CA 9561 r Job Truss Tt pe Qty Ply LGI ?S 2514 FL R50499440 2514-FL F2 FLOOR GIRDER 1 2 Job Reference bona BMC, EVERETT,WA98205.3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:52 2017 Page 1 ID:migzTLih7H1 sSQCFVTnRO6zlaVJ-TQkU_O?4_Tzu1vOg9UZyNYLNKfEVDL49DhD7pszlYYz I Scale=1:11 1 5x6= • A 5x6= B1.5x4 II C u N 6x12 — G E H I 1-5x4 II 1.5x4 11 2.11-8 57 8 b11-0 0.3.8 2_8.0 24114 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0.04 E-F >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.55 Vert(CT) -0.05 E-F >999 360 BCLL O.O Rep Stress Incr NO WB 0.39 HGrz(CT) -0.00 D n/a n/a BCDL 50 Code IRC2015/TPI2014 Matrix-P Weight:49 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 5-11-0 oc purlins, BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr except end verticals WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. (lb/size) F=1648/0-5-8,D=2232/0-5-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-F=-1199/0,C-D=-1199/0,A-B=-3065/0,B-C=-3065/0 WEBS A-E=0/3235,C-E=0/3235 NOTES- 1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at G-9-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plo Vert:O-F=10,A-C=-100 Concentrated Loads(lb) L� Vert:G=-1085 H=-1085 1=-1092WASHY 5 15398� Sr�NAL May 8,2017 ®WARNING.Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. reeree Design valid for use only with MITak'W connectors.This design is based only upon parameters shown•and is for an Individual budding component,not • a truss system.Before use,the building designer must venty the applicability of design parameters and properly incorporate this design into the overall ---building design.Bracalg indicated is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing -MITek' Is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 911A11 EC fabrication,storage,delivery.erection and bracing of trusses and truss systems,see ANSlrrPl1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Insblule.218 N.Lee Street.Suite 31Z Alexandria,VA 22314. Suite 109 I s CA 95610 ' Job Truss _]FLOOR /pe Qty Ply [JoGRefe SS 2514 FL R50499441 2514-FL F3 FLOOR GIRDER 1 rence o tional BMC, EVERETT,WA 98265 32i2 8.030 s Jan 23 2017 MTek Industries,Inc. Mon May 08 13:21:53 2017 Page 1 ID:migzTLjh7H 1 sSQCFVTnRO6zlaVJ-xclt8k?ilm5if3b01B4BWtN32XPymvJRL2hMIzlYYy M Scale=1:18 0 1 5x4 II 012= 1.5x4 II 1.5x4 II 4x12 = 1.5x4 II A K B L C D M E F u u c N 1 H 3x10 = 3x10= 4x8 = 4x8 = 4-M 5.6.8 9-10.0 Plate Offsets(X,Y) 43.8 -- IH:O�-8,0.1-81 [I:0-3-8 0-1-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (!cc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.87 Vert(LL) -0.13 H-1 >870 480 MT20 1851148 TCDL 10.0 Lumber DOL 100 BC 0.77 Vert(CT) -0.18 H-I >625 360 BCLL 0.0 Rep Stress Incr NO WB 055 Horz(CT) 0.03 G n/a n/a BCDL 5.0 Code IRC2015/TP12014 Matrix-RH Weight:92 lb FT=12% LUMBER- BRACING- TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 2-11-6 cc purlins, BOT CHORD 2x6 DF SS except end verticals WEBS 2x4 HF No 2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (lb/size) G=3789/0-4-8,J=3714/0-5-8 Max Grav G=3789(LC 1),J=3718(LC 3) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD A-J=475/0,F-G=990/0,B-C=-9514/0,C-D=-951410,D-E=9514/0 BOT CHORD I-J=0/7419,H-1=0/9514,G-H=016325 WEBS E-G=-6819/0,B-J=-7998/0,E-H=0/3557,B-1=0/2264,C-1=-1075/0,D-H=-1510/0 NOTES- 1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-7-0 cc. Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 cc. Webs connected as follows:2x4-1 raw at 0-7-0 cc,Except member H-E 2x4-1 row at 0-9-0 cc,member I-B 2x4-1 row at 0-9-0 cc ,member I-C 2x4-1 row at 0-9-0 cc,member H-D 2x4-1 row at 0-9-0 cc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)Unbalanced floor live loads have been considered for this design. 4)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 cc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means LOAD CASE(S) StandardLL 8 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Of W '� Uniform Loads(plo �+) Vert:G-J=10,A-F=-100 ti Concentrated Loads(lb) _ Vert:F=-891 E=-852 D=1461 K=-1461 L=-1461 M=-326 A� 51398 is � ' SSI�NAL�N� May 8,2017 AWARNING.Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.1010312015 BEFORE USE. Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not a Ingl e system.Before use,the building designer must verity the applicability of design parameters and properly incorporate Ihis design into the overall I� building design.Bracing indicated Is to proven!Duckling of individual truss web andfor chord members only, enTi AOonan temporary and permanent bracing NOW( �C Is always required for slabildy and to prevent collapse with possible personal Injury and property damage For general guidance regarding the labrlcatlon.storage,delivery•erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Informatlon available from Truss Plate Institute,218 N-Leo Street,Surto 112,Alexandra,VA 22314. Suite 100 Clrus 11e s q 85810 co O D - VV 0 cA Z a m r � . -0 � .cy. m x -1 ° °1. -_r y �c z n X m o m d ( I -� p W N p _ y o n c c m y m a M p y n IWO- �� fD a D a O -DI 7. 3 7 ° _,. sNG�nUc � y �� mm � C <7 Z Dui o -• � m vm ►If 0.1 _ o Z , O lD 7 N C _O_ j a 3 0 N p fD 7' Q m D D n '3 nw, yQ,n..,� o ?� mc� '� ocn a� cm Icy moo av3 �+ 7 D o n n o 0 7 N j 0 N r ? O S�, N C N �•� o A �„<? ID Z Q7.�7oa� cn cDC3a n NET .d, a3 ox gcn �' � p 2 o 0CD o m 2° o �CD m`< D a m OC a v 0'0 2 ,�o 3 Dw m m O vi cnma�; F � ocoi ?: � o-,� m oc � �� �. m ' M. 6�w9'm o@ 3 O o� aaw o 0 o a7"i ao � nany n ID 660 �. N Sr 7 ' 7 ' n.c Z W 7 A Q_.pj Z 0) 0M.a� Quo CCU 0 °1 3 0' cD�7 �2. -1 �d �' w v = m �, m o 3� y =1 -^m ms aw D d 7 O 0 O m m n. N 7' y 3 F y m S to C O V1 S y.N (0 O N d C y cD CD N CL N X• fD Z CD 7 C °•`Z O/ 7 p� 7 N 7 fD p N c2i cc oa uim °' c -m x ° CD 7 0 7 f/1 E' y < CD N tli I CD �w y� �� m TOP CHORD 0) L. DSD �w c �x _ o m Er . N O w cl) rc1g06 m0 Wmy mzmoo CU) � -n Dm � zama 0. mmOn 2m 10 O a cm,) n O Z0 0fD � SCDN T Y! O 0 < ;m, .c m com 7 ate, c y 0 c Vp (D m N> W2-7 cn CD O O to mm v 0 co X CD m N — a co (D 10a C? (0(D > z -ese. 1 cn n — m N- co -n ffin i z '> N �Jl WHO 1 � � s D (D N o Zm y 3 m ` -i m rn w �, m o O O "n m X m v z �y m oN < Z cD x 0 a 's 3 m0 Ol c cn;K N N � i:F CJI CA-5 a 7 fD m TOP CHORD N ' V D1 Ol ? W N '� V7 CD 7-4 Ol N A W N 0 -n O t0 W DO w:-� v OC m0 f0J mc c J m n $ -i o0 CJc<D `_J vm 0m mo o ym Zm 3 Fa 2 �+ 'D ccz J my �C o' � 0> n B 3ID — 70° D D vJ Zd' W`O m O 3 E"n ; ,< Ny v 3 omo 3m ma O C (Q fD N (] (a f0 d O C O J 7 6 y O W O vj _.X (p O ai q ,�.. Q M•= O Df X C,y D� O N O 'rt y V J y (D (D N O O p3 �„0 R9 d m$ 0 oa 3 9 my d.<0 m3 Nm 3c pay m m v_ o ONyj � O m o- �D o d J m o 0 y c y 3 m not OO o 5 N N m 3 o �' m m 07 °• g v d�0 X d "1l y o om < Em a2 ad d a m d MCD J o ° ° o @43 c9 � O 3 my (CD' _ �- � �� ov c 3� 02� aJ �J �- ccDfDi aJ Jm o5'oc � < (p Q� o oS '2 o Om2 0c D2�� y pis 2 �a O y m a m° " a's m 3 3 d p m m y m y 9 0 N CD N 2 ,G y J J 61 tD o �: d y C ,O[i. OFI Q, 0 0 �N �N d� y,, a m n O P' Aa m 3 m mm 7 5 n,= :3.0) m 3 a, '0 'm D"<'y cJ mmcn mfc 7 () <.N oLm 3 my 'o mcD 3m 2�io SON mo 9,L >UFR od m � 3mE v O y O' F C.Q a #0 (o J O m j 2 d 0 a �a Z m m - c an d a 3 J f 7 3 3 y N O C Ol O �p fD d J y m N C A fD a y R. y `< J _m.nl d y O/ 7 1j. nl 7 O N 7 n a f 1 -0 O G)0• Z N O Z C ` y J O j O'10 < 0 41 ` Q J A 10 V 1`< Qd 1 'D fD J C . N �.� j N m 7 V O Z. �ry d .yn � Ol y � �� OQ. y E• 0 O .Ji ,w O y 7 0 O O 0'1 y �j J N 0 O n ? O' y fD y 0 V d �DJ nlJ �J z -� JN 0 � 'C CD QG� � d c o µ _ o m N N O N J .Oi .�Z' 3 7 C O N N 3 7 nl J O .'� O O C fR J 3 V N O D� N CL O �It. . ? C CD 7 .�•CL a C N ^J" N A a N 7 >: CD N OT O J� M N V C y f0 0 3 j J y, fD (p N fD�0 m N �m fD m o �. m o- 0 y m � m d d`� m wit C00i O �o. o m� �� "O 3 m3 N d 0 (DiCD ` 0 o' fuss T NSS 1 ype — - IPIY `HQME$2514•A RF 251" Al Common Supported Gable 1 1 IJob Reference(Optional) EVERETT,WA 98 212 8.000 s Jul 15 2016 MiTek Industries,Inc,Mon May 0815 14:30 2017 Pegs 1 ID:migzTL)h7H1sSQCFVTnRO6zlaVJ-4_w69Bygl DEkReKNDzpGIRNCIbCBfrGNkjgzlV8l 1 0 8-3-0 16.6-0 17-&0 14)-0 8-3-0 gip �_' p 0 1 Scale:3/8"=1' 4x5= F 5.00 F12 E G S T UV H D T C T I T T B 171 J K �o 3x4= R Q P O N M L 3x4= 18-9-0 I 16.6-0 16-6-0 TODING(psi) 2 CL 5 0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.11 Vert(LL) 0.00 J n/r 180 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.06 Vert(CT) 0.00 K n/r 180 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 J n/a n1a ei pl 10 0 Code IRC2015/TP12014 (Matrix) Weight:57 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 MiTek recommends that Stabilizens and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8=16211646-0 (min.0-2-8),J=162/16-" (min.0-2-8),0=159116-6-0 (min.0-2-8),P=169/16-" (min.0-2-8),Q=164/1646.O (min.0-2-8) ,R=182/16-6-0 (min.0-2-8),N=169/16-6-0 (min.0-2-8),M=164/16-6-0 (min.0-2-8),L=182116-6-0 (min.0-2-8) Max Horz B=-46(LC 13) Max UpliftB=-22(LC 8),J=-24(LC 9),P=-25(LC 12),Q=-25(LC 12),R=-23(LC 12),N=-24(LC 13),M=-25(LC 13),L=-23(LC 13) Max GravB=178(LC 18),J=178(LC 18),0=159(LC 1),P=213(LC 19),Q=170(LC 19),R=182(LC 1),N=213(LC 20),M=170(LC 20),L=182(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/41,B-C=-56/35,C-D=-39/39,D-S=-35/60,S-T=-16/61,E-T=-16/64,E-F=-43/106,F-G=-43/106,G-U=-16/64,U-V=-16/61,H-V=-35/60, H-1=-35/35,I-J=-40/19,J-K=0/41 BOT CHORD B-R=-7/53,Q-R=-7/53,P-Q=-7/53,O-P=-7/53,N-0=-7/53,M-N=-7/53,L-M=-7/53,J-L=-7/53 WEBS F-0=-120/6,E-P=-173/92,D-Q=-131/57,C-R=-137/78,G-N=-173/92,H-M=-131/57,I-L=-137/78 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-3-0,Exterior(2)2-3-0 to 5-3-0,Corner(3) 5-3-0 to 8-3-0,Exterior(2)11-0-0 to 14-3-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Detaits as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCL ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;C1=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 22 lb uplift at joint B,24 lb uplift at joint J,25 lb uplift at joint P,25 lb uplift at joint Q,23 lb uplift at joint R,24 lb uplift at joint N,25 lb uplift at joint M and 23 lb uplift at joint L. 13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Job russ TCOUM Type y y HOMES 2514•A RF 2514•A A2 on 1 1 Job Reference ojonal BMC,EVERETT,WA 98205.3212 8.000 s Jul 15 2016 MiTek IndusWes,Ina Mon May 08 15:14:312017 Page 1 1 g o 4 7� 8-3-0 ID:migzTLjh7H1sSQCFVrnRO6ziaVJ-YAUUNXySeHL4MbCWx12 xwwUO2oz_sTcQDKeJ&'v H6FOGzlVes 14)o 4-7-4 3-7-12 3 7-11 12 4-7-4 f11--0-0 Scale:3/8"=1' 4x5= D 5.00 12 2x4 K L M 2x4 J E C I N B F G [o 3x6= H 3x10= 3x6= 18-9-0 18-9-0 i 8-3-0 164-0 83-0 830 LOADTCLL (Ps25 0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.24 Vert(LL) -0.09 F-H >999 240 MT20 185/148 TCDL 7,0 Lumber DOL 1.15 BC 0.55 Vert(CT) -0.19 F-H >999 180 BCLL 0.0 Rep Stress Incr YES WB 012 Horz(CT) 0.03 F n/a n/a BCDL 10.0 Code IRC2015/TP12014 (Matrix) Weight:56 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 4.9-6 oc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance g REACTIONS. (lb/size) 6=752/0-5-8 (min.0-1-8),F=752/0-5-8 (min.0-1-8) with Stabillzer Installation uide. Max Horz B=46(LC 13) Max UpliftB=-49(LC 12).F=-49(LC 13) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/42,B-1=-1234/107,C-1=-1197/120,C-J=-939/71,J-K=-927/73,D-K=-891/82,D-L=-891/82,L-M=-927/73,E-M=-939/71,E-N=-1197/120, F-N=-1234/107,F-G=0/42 BOT CHORD B-H=-70/1093,F-H=-53/1093 WEBS D-H=0/449,E-H=-353/107,C-H=-353/107 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf,h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 5-3-0,Exterior(2) 5-3-0 to 8-3-0.Interior(1)11-3-0 to 14-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 49 lb uplift at joint B and 49 lb uplift at joint F. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Job russ Truss I ype L::=31Job TOMES 2514-A RF 2514A B2 Common Girder Reference(optional) SMC.EVERM.WA 88 05 3212 000 a Jut 152016 MITek industries,Inc Mon May 0815:14:33 2017 Pagel 10-9-0 18-9-o tD:mtgzTLjh7f•ItsSQCFVTnRO6zlaVJ-UZbFnDJAvbobvMv2LXWuO387P4ko(L5YEcOKAtA9aq 41-11 7-2-12 11-9.0 23.6-0 4-1-11 3-1-1 4-6-4 4 8 4 3 1-t 4-1-11 Scale=1:40.6 4x5= D 5.00 12 6x8 6x8 C M N E 3x6 3x6 B F A G wigii 11 RA [d Q K P L Q R S T J U V I W H X Y 4x6- 4x6= 3x10 II 12x12= 8x12= 12xl2= 3x10 II 18-9-0 18-9-0 18-9-0 Orb 1z 2 fa12 41-11 7-2-12 11-9 0 16-3-4 194-5 22.6-12 23$Q _ �-000 ' 1-8-15 I 3 1-I_ "-3 4 4-6-4 + 3 2-7 �0 Plate Offsets tX Y)__LJ:0-6-0.0-4-8�__ TCLLLOAD (ps25.0 SPACING- 2-0-0 CST. DEFL. in (loc) I/deft L/d PLATES GRIP (Roof Snow=25 0) Plate Grip COL 1.15 TC 0.42 Vert(LL) -0-10 I-J >999 240 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.62 Vert(CT) -0 17 I-J >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.60 Horz(CT) 0-02 G n/a n/a BCDL 10.0 Code IRC2015/TP12014 (Matrix) Weight:340 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 5-11-0 cc purlins. BOT CHORD 2x6 OF SS BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. WEBS 2x4 HF No.2 REACTIONS. (lb/size) A=1702/0-5-8 (min.0-1-8),G=6544/0-5-8 (min.0-2-5),K=13263/0-5-8 (min.0-4-11) Max HorzA=-58(LC 28) Max UpliftA=-92(LC 10),G=-350(LC 11),K=-668(LC 10) Max GravA=1745(LC 16),G=6566(LC 17),K=13263(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=-68/1146,B-C=-213/4463,C-M=-3399/210,D-M=-3387/223,D-N=-3357/213,E-N=-3427/200,E-F=-8639/481,F-G=-11670/629 BOT CHORD A-O=-1009/127,O-P=-1009/127,L-P=-1009/127,L-Q=-1009/127,Q-R=-1009/127,K-R=-1009/127,K-S=-4084/273,S-T=-4084/273,J-T=-4084/273 J-U=-377/7963,U-V=-377/7963,I-V=-377/7963,I-W=-549/10700,H-W=-549/10700,H-X=-549/10700,X-Y=-549/10700,G-Y=-549/10700 WEBS D-J=-103/2310,E-J=-5815/353,E-1=-220/4900,F-1=-3134/196,F-H=-94/2547,C-J=-424/8570,C-K=-7934/426,B-K=-3615/220,B-L=-105/2758 NOTES- 1)Special connection required to distribute bottom chord loads equally between all plies. 2)3-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-7-0 cc. Bottom chords connected as follows:2x6-3 rows staggered at 0-4-0 cc. Webs connected as follows:2x4-1 row at 0-9-0 cc,Except member E-I 2x4-2 rows staggered at 0-4-0 cc. 3)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S) section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 4)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4 2psf;BC0L=6.0psf;h=25ft,Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone;cantilever left and right exposed end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 5)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1 1 6)Unbalanced snow loads have been considered for this design. 7)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 92 lb uplift at joint A,350 lb uplift at joint G and 668 lb uplift at joint K. 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)1637 lb down and 86 lb up at 0-6-12,1630 lb down and 93 lb up at 2-6-12,1630 lb down and 93 lb up at 4-6-12,1630 lb down and 93 lb up at 6-6-12,1630 lb down and 93 lb up at 8-6-12,1630 lb down and 93 lb up at 10-6-12,1630 lb down and 93 lb up at 12-6-12,1630 lb down and 93 lb up at 14-6-12,1630 lb down and 93 lb up at 16-6-12,1630 lb down and 93 lb up at 18-6-12,and 1630 lb down and 93 lb up at 20-6-12,and 1633 lb down and 90 lb up at 22-6-12 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. Job Truss 1 russ 1 ype [y P� TOMES 2514-A RF 2514-A C1 Common Supported Gable 1 1 Job Reference option BMC,E ETC WA 882Q53212 8.000 s Jul 15 2016E MiTek Industnea,Inc.Man May 0815:14 35 2 17 Page 1 t ID:migzTLjh7H1sSQCFVTnRO6zlaVJ-Rxj?Cu?ziWsWgDWHAmZ?zpSYsDumGQ007Y5VP1zIV80 1 0 20-0-0 40-0-0 41-" 1 20-0.0 20-" -6-0 Scale=1:73.7 5.00 12 4x5= L M 3x4� K I J N 3x4 H O G P Q F R E 8 g S D 6 8 T AO GT1 4 5 5 3 STt1 AP 2 A8 - - VW 0 3x4= AN AM AL AK AJ Al AH AG AF AE AD AC AS AA Z Y X 3x4= 5x6= 18-9-0 1 40-0-0 Plate Offsets(X.Y)- IP:0-0-0 0.0-0I.fAF:0-3-0.0-3-0] 40A•0 _ LOAD TCLL (ps25 0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.15 Vert(LL) -0,00 V n/r 180 MT20 185/148 TCDL 7.0 Lumber DOL 1 15 BC 0.07 Vert(CT) 0.00 W n/r 180 BCLL 0•0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.01 V n/a n/a BCDL IMID Code IRC2015ITP12014 (Matrix) Weight:198 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 WEBS 1 Row at midpt L-AF MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation Quide. REACTIONS. (lb/size) V=216/40-0-0 (min.0-3-12),AF=160/40-0-0 (min.0-3-12).AG=1 6 814 0-0-0 (min.0-3-12),AH=168/40-0-0 (min.0-3-12),AI=168/40-0-0 (min.0-3-12),AJ=169/40-0-0 (min.0-3-12),AK=164/40-0-0 (min.0-3-12),AL=185/40-0-0 (min.0-3-12),AM=101/40-0-0 (min.0-3-12), AN=326/40-0-0 (min.0-3-12),AE=168/40-0-0 (min.0-3-12),AD=168/40-0-0 (min.0-3-12).AC=168/40-0-0 (min.0-3-12),AB=169/40-0-0 (min.0-3-12),AA=164/40-0-0 (min.0-3-12),Z=185/40-0-0 (min.0-3-12),Y=101/40-0-0 (min.0-3-12),X=326/40-0-0 (min.0-3-12), B=216/40-0-0 (min.0-3-12) Max Horz B=-105(LC 13) Max UpliRV=-7(LC 9),AG=-20(LC 12),AH=-26(LC 12),AI=-24(LC 12),AJ=-24(LC 12),AK=-24(LC 12),AL=-26(LC 12),AM=-16(LC 12),AN=-45(LC 12),AE=-18(LC 13),AD=-27(LC 13),AC=-24(LC 13).AB=-24(LC 13),AA=-24(LC 13),Z=-26(LC 13),Y=-16(LC 13),X=-45(LC 13), B=-6(LC 13) Max GravV=216(LC 20),AF=169(LC 25),AG=246(LC 19),AH=243(LC 19),AI=214(LC 19),AJ=169(LC 1),AK=164(LC 19),AL=185(LC 1). AM=101(LC 19),AN=326(LC 1),AE=246(LC 20).AD=243(LC 20),AC=214(LC 20),AB=169(LC 1),AA=164(LC 20),Z=185(LC 1), Y=101(LC 20),X=326(LC 1),B=216(LC 19) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/41,B-AO=-118/38,C-AO=-108/67,C-D=-86/56,D-E=-64/65,E-F=-53/80,F-G=-39/94,G-H=-38/107, H-1=-29/110,I-J=-48/136,J-K=-58/174,K-L=-66/214,L-M=-66/214,M-N=-58/174,N-0=48/136, O-P=-29/110,P-Q=-38/107,Q-R=-35/82,R-S=-36/55,S-T=-33/29,T-U=-55/14,U-AP=-67/41,V-AP=-87/21, V-W=0/41 BOT CHORD B-AN=-25/112,AM-AN=-25/112,AL-AM=-25/112,AK-AL=-25/112,AJ-AK=-25/112,AI-AJ=-25/112, AH-AI=-25/112,AG-AH=-25/112,AF-AG=-25/112,AE-AF=-25/112,AD-AE=-25/112,AC-AD=-25/112, AB-AC=-25/112,AA-AB=-25/112,Z-AA=-25/112,Y-Z=-25/112,X-Y=-25/112,V-X=-25/112 WEBS L-AF=-129/0,K-AG=-206/88,J-AH=-203/80,I-AI=-174/52,G-AJ=-128/56,F-AK=-126/53,E-AL=-138/61, D-AM=-86/35,C-AN=-230/123,M-AE=-206/88,N-AD=-203/80,O-AC=-174/52,Q-AB=-128/56, R-AA=-126/53,S-Z=-138/61,T-Y=-86/35,U-X=-230/123 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Comer(3)-1-0-0 to 3-0-0,Exterior(2)3-0.0 to 16-0-0.Corner(3) 16-0-0 to 20-0-0,Exterior(2)24-0-0 to 37-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. V6ni1n1ueQ On��sge TBn designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Job I russ — Tr—uss.Ty,—e myy TOMES 2614-A RF 7.514A C1 ommn Supported Gable 1 1 r IJob Reference(opffona_IL_ BMC,EVERETT.WA 982053212 8.000 s Jul 15 2016 MITek Industries,Inc.Mon May 08 15:14:35 2017 Page 2 NOTES- ID:migzTLjh7H1 SSQCFVTnRO6zlaVJ-Rxj?Cu?ziW$WgDWHAmZ?zp8YsDumGQ00?Y5VP7 zl Veo 11)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 7 lb uplift at joint V.20 lb uplift at joint AG,26 lb uplift at joint AH,24 lb uplift at joint Al,24 lb uplift at joint AJ 24 lb uplift at joint AK,26 to uplift at joint AL,16 lb uplift at joint AM,45 lb uplift at joint AN,18 lb uplift at joint AE,27 lb uplift at joint AD,24 lb uplift at joint AC,24 lb uplift at joint AB,24 lb uplift at joint AA,26 lb uplift at joint Z,16 lb uplift at joint Y,45 lb uplift at joint X and 6 lb uplift at joint B. 13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSl1TPI 1. J100 Truss Tc.... ype 1yTOMES 2514-A RF 2514-A C2 5 1 Job Reference(optionap BMC,EVERETT,WA 882053212 8.000 s Jul t 5 2016 MTek Industries.Inc.Mon Mey 08 15*14:36 2017 Pape 1 ID:migzTLjh7H1sSQCFVrnR06ziaVJ-v7FINQEObTq_NSM5UjU4EVOhVWd4b?mYE IV8n 1f-0t7bjT" 7-1-3 13 9 4 20 0 0 26-2-12 32-10-13 40-M � 0 7-1-3 6.8.0 0.2-12 6-" 7-1-3 Scale=1:72.8 5.00 12 4x6= E 5x8 5x8 N � D F 2x4 2x4 i C 1IV3 VV3 G M P A B 1 H I I� 45= L Q R K S T J 45= 3x4= 5x8= 3x4= 18-9-0 18-9-0 l ta314 20-0-0 29-&2 40-0-0 10 3 14 9- 9.8-2 I 10-3-14 Plate Offsets(X_Y)— fD:04-0.0-3-41.IF:04-0.0-3.41, 04-0.0-3-M _ LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.96 Vert LL -0 36 J-K >999 240 MT20 185/148 TCDL(Roof Snow--25.0) ( 7.0 Lumber DOL 1.15 BC 0.73 Vert(CT) -0 63 J-K >756 180 BCLL 0.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.16 H n/a n/a BCDL 10.0 Code IRC2015/TP12014 (Matrix) Weight:161 lb FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural woad sheathing directly applied. BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 WEBS 1 Row at midpt F-K,D-K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance REACTIONS. (lb/size) H=1739/0-5-8 (min.0-1-14),8=1739/0-5-8 (min.0-1-14) with Stabilizer Installation guide. Max Horz B=-105(LC 13) Max UpliftH=-93(LC 13),B=-93(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/42,B-M=-3564/172,C-M=-3490/193,C-D=-3209/166,D-N=-2242/177,E-N=-2165/195,E-0=-2165/195,F-0=-2242/177,F-G=-3209/166, G-P=-3490/193,H-P=-3564/172,H-1=0/42 BOT CHORD B-L=-206/3199,L-Q=-94/2587,Q-R=-94/2587,K-R=-94/2587,K-S=-49/2587,S-T=-49/2587,J-T=-49/2587,H-J=-104/3199 WEBS F-K=-931/155,E-K=-5/1260,F-J=0/580,G-J=-422/161,C-L=-422/161,D-K=-932/155,D-L=0/580 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft,Cat.II;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Extedor(2)-1-0-0 to 3-0-0,Interior(1)3-0-0 to 16-0-0,Exterior(2) 16-0.0 to 20-0-0,Interior(1)24-0-0 to 37-0-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf---25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 93 lb uplift at joint H and 93 lb uplift at joint B. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSlfTPI 1. Nits cuss Type >T I 10MES 2514-A RF t 2514-A C3 Common 12 i Job Reference o Iona 8MC,FVERffrWA 98205.3212 8.000 a Ju"1 5 2016 MTek Industries,Inc. Mon May 08 15-14,37 2017 Page 1 1 ID:migzTLjh7H1sSQCFVfnR08zlaV-NKrmdalDD76E4WggHBbT2EEiglotkl3hSsw lvem 1 7-1-3 13 9 4 20-0-0 ?i52-12 32-10-13 39-7-6 00 7-13 OV 82-12 6-2-12 880 88-9 Scale=1:72.2 5.00 12 4x6= E 5x8 M N 5x8 D F 2x4 2x4 C W3 W3 G O L A B H 4x5= K P Q J R S I 5x6= 3x4= 5x8= 3x4= 18-9-0 18-9-0 10-3-14 20-0-0 2941-2 39-7-6 10314 982 F 98-2 Plate Offsets fX•Yl— ID:04-0.0-3-41,IF:0.4-0.0-3-41.IJ:04.0 0-3-01 LOATCLDING(Ps25 0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP (Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.95 Vert(LL) -0.35 J-K >999 240 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.73 Vert(CT) -0.62 J-K >765 180 BCLL 0.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.16 H n/a n/a BCD[- 100 Code IRC2015/TPI2014 (Matrix) Weight:160 Ib FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 HF No.2 WEBS 1 Row at midpt F-J,D-J WEDGE MITek recommends that Stabilizers and required cross 1 Right:2x4 HF No.2 bracing be installed during truss erection,in accordance REACTIONS. (lb/size) 6=1731I0-5-8 (min.0-1-14),H=1650/Mechanical with Stabilizer Installation guide. Max Horz B=109(LC 16) Max UpliftB=-93(LC 12),H=-73(LC 13) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/42,B-L=-3544/175,C-L=-3470/196,C-D=-3189/169,D-M=-2221/180,E-M=-2145/198,E-N=-2145/198,F-N=-2222/185,F-G=-3149/181, G-0=-3377/210,H-0=-3464/199 BOT CHORD B-K=-211/3181,K-P=-99/2569,P-Q=-99/2569,J-Q=-99/2569,J-R=-69/2551,R-S=-69/2551,I-S=-69/2551,H-1=-137/3109 WEBS E-J=-7/1245,F-J=-909/156,F-1=0/544,G-1=-375/158,D-J=-926/155,D-K=0/581,C-K=422/161 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11,Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-11-9,Interior(1)2-11-9 to 16-0-7.Exterior(2) 16-0-7 to 20-0-0.Interior(1)23-11-9 to 35-7-1 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber OOL=1.33 plate grip DOL=1.33 2)TCLL:ASCE 7-10;Pf--25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Refer to girder(s)for truss to truss connections. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 93 lb uplift at joint B and 73 lb Uplift at joint H. 10)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. job Truss 1 russ I ype Qt ply TOMES 2514-A RF y 2514-A 04 GABLE 1 1 Lob Reference(opl(onal BMC.EVERETT.WA 982OS3212 8.000 s Jul 15 2016 MiTak Industries.Inc Mon May 0815.14:38 2017 eeppee 1 1 -0 ID:migzTLih7H1sSOCFVrnRO6ziaVJ-rVVP8rw2r REShgFsrv7ibRm36QwTTn7rhWJ97MzIVal -� 20-0-0 39-7.6 1-0-0 20-" 19-7-6 Scale=1:73.2 5.00 12 45= L M 3x4 K J N 3x4 H O G P Q F R Mg D E 6 7 8 8 7 6 S T AN 13T1 3 5 5 4 STU AO 2 3 2 �A B - _ - V Id 3x4= AM AL AK AJ Al AH AG AF AE AD AC AB AA Z Y X W 3x4= 5x6= 18-9-0 39-7-6 39-7-6 Plate Offsets(%Y) IAE:0-3-0.0-3-01 TOADING(psf) 25 0 SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft L/d PLATES GRIP CLL(Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.15 Vert(LL) -0.00 A n/r 180 MT20 185/148 TCDL 7.0 Lumber DOL 1.15 BC 0.07 Vert(CT) 0.00 A n/r 180 BCDL .0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.01 V n/a n/a BCDL 10,0 Code IRC2015/TPI2014 (Matrix) Weight:196 1b FT=10% LUMBER- BRACING- TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 HF No.2 WEBS 1 Row at midpt L-AE MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) V=129/39-7-6 (min.0-3-10),AE=160/39-7-6 (min.0-3-10),AF=168/39-7-6 (min.0-3-10),AG=168139-7-6 (min.0-3-10),AH=168139-7-6 (min.0-3-10),AI=169/39-7-6 (min.0-3-10),AJ=164/39-7-6 (min.0-3-10),AK=185/39-7-6 (min.0-3-10).AL=101/39-7-8 (min.0-3-10), AM=326/39-7-6 (min.0-3-10),AD=168/39-7-6 (min.0-3-10).AC=168/39-7-6 (min.0-3-10),AB=168139-7-6 (min.0-3-10).AA=169/39-7-6 (min.0-3-10),Z=164/39-7-6 (min.0-3-10).Y=182/39-7-6 (min.0-3-10),X=110/39-7-6 (min.0-3-10).W=309/39-7-6 (min.0-3-10), B=216/39-7-6 (min.0-3-10) Max Horz B=109(LC 12) Max UpliftAF=-20(LC 12),AG=-26(LC 12),AH=-24(LC 12),AI=-24(LC 12).AJ=-24(LC 12),AK=26(LC 12).AL=-16(LC 12),AM=-45(LC 12). AD=-18(LC 13).AC=27(1_C 13).A6=-24(LC 13),AA=-24(LC 13),Z=-24(LC 13),Y=-26(LC 13),X=-15(LC 13),W=50(LC 13),B=4(LC 13) Max GravV=129(LC 20),AE=167(LC 25).AF=243(LC 19),AG=240(LC 19),AH=202(LC 19),AI=169(LC 1).AJ=165(LC 19).AK=185(LC 1). AL=101(LC 19).AM=326(LC 1).AD=246(LC 20),AC=243(LC 20),AB=214(LC 20),AA=169(LC 1),Z=165(LC 20),Y=182(LC 1),X=111(LC 20),W=309(LC 1),B=216(LC 1) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD A-B=0/41,B-AN=-120/34,C-AN=-110/64,C-D=-88/52,D-E=-66/61,E-F=-54/76,F-G=-41/90,G-H=-39/103, H-1=-29/106,I-J=-49/132,J-K=-59/169,K-L=-67/210,L-M=-67/210,M-N=-59/169,N-O=-49/132, O-P=-29/106,P-Q=-39/103,Q-R=-36/78,R-S=-36/51,S-T=-36/27,T-AO=-50/13,U-AO=-57/3,U-V=-90/42 BOT CHORD B-AM=-27/105,AL-AM=-27/105,AK-AL=-27/105,AJ-AK=-27/105,AI-AJ=-27/105,AH-AI=-27/105, AG-AH=-27/105,AF-AG=-27/105,AE-AF=-27/105,AD-AE=-27/105,AC-AD=-27/105,AB-AC=-27/105, AA-AB=-27/105,Z-AA=-27/105,Y-Z=-27/105,X-Y=-27/105,W-X=-27/105,V-W=-27/105 WEBS L-AE=-127/0,K-AF=-203/88,J-AG=-200/80,I-AH=-163/52,G-AI=-128/56,F-AJ=-126/53,E-AK=-138/61, D-AL=-87/36,C-AM=-230/122,M-AD=-206/88,N-AC=-203/80,O-AB=-174/52,Q-AA=-128/56,R-Z=-127/53, S-Y=-136/61,T-X=-94/37,U-W=-214/148 NOTES- 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf BCDL=6.Opsf,,h=25ft;Cat.11;Exp B; enclosed;MWFRS(envelope)automatic zone and C-C Comer(3)-1-0-0 to 2-11-9,Extedor(2)2-11-9 to 16-0-0,Corner(3) 16-0-0 to 20-0-0.Exterior(2)24-0-0 to 35-7-13 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by Co&,0—ecygn pag�tZbetween the bottom chord and any other members. W 0 rusT—s' I nrss I We yam- IOME3 2574,A RF T 2514-A JC4 GABLE 1 1 IJob Reference(optionap 6MC.EVERETT.WA 98205-32:2 8.000 8 Ai1152ot8 MiTek indaN6es.Inc, Mon May 08 15,14:387017 Par NOTES- MIP 2 IU:mfgzTLjh7H1sSQCFVfnRO6ziaVJ 8rvv2r RE511gFsrv7ibRm36QwTTn7rhWJ91MzIV81 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 20 Ib uplift at joint AF,26 Ib uplift at joint AG,24 lb uplift at joint AH, 24 lb uplift at joint AI,24 lb uplift at joint AJ,26 Ib uplift at joint AK,16 Ib uplift at joint AL,45 Ib uplift at joint AM,18 lb uplift at joint AD,27 lb uplift at joint AC,24 lb uplift at joint AB,24 lb uplift at joint AA,24 lb uplift at Joint Z,26 Ib uplift at Joint Y,151b uplift at joint X,50 Ib uplift at joint W and 4 Ib uplift at joint B. 13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/fPI 1. Date: 04/10/2026 Permit#: 1718 Perm t Date: 11/01/2017 Review Date: 11/01/2017 Perm Type: RESIDENTIAL SINGLE FAMILY Review Type: RESIDENTIAL SINGLE FAMILY Target Date: 11/08/2017 Scheduled Time 00:00 Com pleted Date: 11/02/2017 Description: Site plan m xts all land use regulations. Review Status: Assigned To: Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information Parcel#: 01166900000300 L GI HOMES -WASHINGTON LLC LGI HOMES -WASHINGTON LLC 1 450 LAKE ROBBINS DR STE 430 9016 168th Street NE T HE WOODLANDS, WA77380 Zoning: 111 Single Fam iy Residence - DetachedLot: 3Block: Permit#: 1718 Permit Date: 11/01/17 Permit Type: RESIDENTIAL SINGLE FAMILY Project Nam e Gregory Park Applicant Nam a LGI Horn cs -Washington, LLC Applicant Address: 9028 168th Street NE Applicant, City, State, Zip: Arlingotn,WA98223 Contact: Matt Adam s Phone: 425-785-0797 Em al: m at.adam s@lgihom cs.com Scope of Work: New SFR Valuation: 309450.70 Square Feet: 2894 Num ber of Stories: 2 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/28/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wner Nam e Ovner Phone Zoning LGI HOMES- 01166900000300 9 016 168th Street NE WASHINGTON Residence Single Dam iy -Detached LLC Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# LGI HOMES- 12951 BELRED CONSTRUCTION Labor and LGIHOHL857MB WASHINGTON LLC RD#150 CONTRACTOR Industries Inspections Date I nspection Type D escription S cheduled Date C om Iieted Date I nspector S tatus 01/17/2018 R20.SFR/DUPLEX Downspout Connection- 01/17/2018 0 1/17/2018 A pproved FINAL Inspection by David Spencer O1/09/2018 R20.SFR/DUPLEX Approved FINAL Plan Reviews Date Review Type D escription A ssigned To R eview Status 11/O1/2017 RESIDENTIAL SINGLE Site plan m(ets all land use regulations. FAMILY 11/01/2017 RESIDENTIAL SINGLE BUILDING FAMILY Fees Fee D escription N otes A m aunt Building Perm i T able 4-1 $3,076.58 Building Plan Review T able 4-2 $1,999.78 Forced Air Heat f ee per Btu $25.00 Gas Piping/Units E nter#of units $10.00 Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base P erm i Fee $25.00 Park-Com m uity SF S ingle Fam iy $1,662.00 Plum ling Base Perm i Fee $25.00 Mechanical Comm ecial Perm i T able 4-7;Per Unit 1 6 @$12 $192.00 Processing/Technology $25.00 State Surcharge- 1 st DU R esidential- 1 st Unit $4.50 Traffic Mitigation-SF S ingle Fam iy $3,355.00 Water Heater(Tank) $25.00 Total $10,449.86 Attached Letters Date Letter D escription 11/14/2017 Building Perm i Paym Bits Date Paid By D escription P aym ant Type A ccepted By A m aunt 11/01/2017 LGI Hom cs-Washington Check#5711 K ristin Foster $8,450.08 LLC 11/01/2017 LGI Hom cs-Washington Check#5710 K ristin Foster $1,999.78 O itstanding Balance $0.00 Notes Date Note C reated By: 11/01/2017 Application needs to be signed.KF K ristin Foster Uploaded Files Date File Nam e 11/28/2017 2803033-1718 Issued Perm i.pdf 11/02/2017 2751658-1718 Signed Application.pdf 11/01/2017 2746860-1718 Site Plan.pdf 11/01/2017 2746861-1718 Application.pdf