Project Address:
9020 169th Street NE Plat: Gregory Park Lot 80
V31 Single-family ❑ Duplex ❑I Townhouse 1�11 Addition DI Accessory structure
Proposed Area: 1" Floor: 963 2nd Floor: 1196 Garage: 418 Total SF: 2577
Describe Proposal (include cross street):
Application for new single family residence to be located at 9020 169th Street NE. Cross street is 91st,DIr
Valuation:
Owner: LGI Homes - Washington LLC
Address:
9028 168th Street NE City: Arlington State:WA Zip Code:98223
.
Phone: 425-785-0797 Email: matt.adams@lgihomes.com
Applicant: LGI Homes - Washington LLC
Address:
9028 168th Street NE City: State: Zip Code:Arlington WA 98223
_ .
Phone:
425-785-0797 Email: matt.adams@lgihomes.com
Contractor: LGI Homes - Washington LLC
9028 168th Street NE Arlington WA 98223
Address: City: State: Zip Code:
Phone:
425-785-0797 Email: matt.adams@lgihomes.com
Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019
0 711AW
6/16LP Page 1 of 3
RESIDENTIAL PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
KJ1 Bath/Shower Combo (4.0) x MI Sink (1.5) x 1
16 Shower (2.0) x 1 Cal Lavatory (1.0) x 4
Ul Clothes Washer (4.0) x MIS Water Closet(2.5) x 3
91; Dishwasher (1.5) x 1 ZI Water Heater x 1
M1 Hose Bibb (2.5) x 2 Water Heater Model #
E3 Other (list) x 1 AO Smith HPTU - 50N
Plumbing Section Continued
Proposed Water Piping Size: 3/411 Proposed DWV Material: ABS
Proposed Piping Material: PEX Proposed DWV Size: 2"
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
6/16LP Page 2 of 3
RESIDENTIAL PERMIT APPLICATION
`y ?
Department of Community & Economic Development
City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
Mechanical Section (continue filling out if mechanical equipment is involved)
Select proposed appliances:
FA1 Furnace (80+) Model# Bryant 915SA30040514 AFUE 95%
❑1 Heat Pump Model# SEER HSPE
❑ AC Unit Model# SEER
LJ Type II Hood Commercial Cooking Appliance D1 Hydronic Piping
01 Boiler ❑ Solid-Fuel Appliance al PV System
01 Fireplace Insert ❑1 Outdoor BBQ Storage Tank
21 Freestanding Stove Di Gas Piping 01 Other
Gas Piping Information
Not Applicable: 01
Black Steel
Pipe Material: Pipe Size: 1 Total BTU's of all Appliances: 120,000
Distance from Meter to Furthest Appliance: 5
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper combustion air and venting required for all appliances
• A shut-off is required within 6 feet of all appliances
Applicant Signature: Date:
Print Applicants Name:
6/16LP Page 3 of 3
� r .
CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:9020 169th Street NE Permit#:1696
Parcel#:01166900008000 Valuation:269962.41
OWNER APPLICANT CONTRACTOR
Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC
Address: 1450 LAKE ROBBINS DR STE 430 Address:9026 168th Street NE Address: 11410 NE 124th Street,Ste#103
City,State Zip:THE WOODLANDS,WA 77380 City,State Zip:Arlington,WA 98223 City,State Zip:Kirkland,WA 98034
Phone: Phone:425-785-0797 Phone:360-353-0588
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Single Family Residence CODE YEAR: 2015
STORIES: 2 CONST.TYPE: `/-B
DWELLING UNITS: 1 OCC GROUP: R-3
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
i AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC1l0.
S LE TA .NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
a4i c ed o Arlingtoi #3101.
Signature Print Name Date Released By atc
CONDITIONS
ADHERE TO APPROVED PLANS.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
10/24/2017 Building Permit Fee $2,759.38
10/24/2017 Building Plan Review Fee $1,793.60
10/24/2017 Furnace $25.00
10/24/2017 Gas Outlets Base Fee 1 to 5 $10.00
10/24/2017 Mechanical Fee(Enter Fixture Fee) $25.00
10/24/2017 Mechanical Permit Base Fee $25.00
10/24/2017 Park-Community SF $1,662.00
10/24/2017 Plumbing Permit Base Fee $25.00
10/24/2017 Plumbing Permit Fee(Enter Fixture Fee) $168 00
10/24/2017 Processing/Technology Fee $25.00
10/24/2017 State Building Code Surcharge Fee $4.50
10/24/2017 Traffic Mitigation-City $3,355.00
10/24/2017 Water Heater $25 00
Total Due: $9,902.48
focal["I)nwnt: $9.902.48
Balancr Due: 50.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
SETBACKS NOTES.
FRONT 20' •BUILDING BYMEN-96WS ARE TO
SYDE 5' FACE OF FOUNDAAON
8"WA7ER 169TH ST. WE REAR 5' 4PADING 9YONN AS D£SrG1{/
co A07VAL LOCAAOW MAY VARY
5tO 7 SPORE LUR/;f VAY R7 PUBLIC ROAD
-I— •-%T FENCE TO BE INSTALLED PER
8"SEW aTY OF ARLINGTOW S STANDARD
10.00'P UC •a T fENCE TO BE INSTALLED ON
UAU COWNECA STGWM LLEANOUT. PAARLM T SrDE OF BUILDING
EASEM COVNECT ROOD AND •CaVSAPUCAOW EN7RANCE 70 BE
° J o
FOOANG DRAINS INSTALLED PER CITY Ole
v
- - ARLING76W:1 STANDARDS
N8920'49"W° e ° 4 STORM NO TES:
° �` •7ESC INSTALLED PRIOR 70 25.40 ,p 90o a C067RUC77aW
•BAR£SOILS COVERED W7H MULCH
$ o o 6 R AN07H R APPROVED 8MP
25.VO' 20.IV 0 0� -XPSOIL PER W517OF BMP T513
a SBL , 1 'f o (&T 12-DEP7H)
•ALL 6WS17E RUNOFF CONNEC70 TO
a ' PR/VAT£ST"37UB
VA - - - - .9TF 9YALL BE STABILIZED PRIOR
20.00 $ $10.415 \ -44 70 FINALIZED BUILDING PERMIT BEING
GARAGE 1.00'ROOF 1 4,50 4 SITE NOTES.
OVERHANG I \ •770Y&INE FOOANG DRAINS AND
BUILDING-� ROOF DRAINS 70 PERMANENT
OUTLINE O STORM DRAINAGE SYSTEM PER
o !� APPROVED PLAT DRA/NA6F PLAN
LOT 80 OV FILE W7H PIE COUNTY.
•"� `O PRApOSED RESJDENCE o H •AREA OF DIS7URBANar INGYUDES
_ KEFU-2159 GAR416F R/GAIT
o SNARE LOT.
0
� � '� ��� LEGEND:
o- BLOW OFF
m00 ® WA7ER MFU
I 10.00 \ 4( RRE HYDRANT
f I AIR VAC
5.00'8Sl9L
$ EWSANG PA AO 39 Sr ® CA7W BASIN
CONTOUR(TYP.) S O GYfMaIT
WA ER O
MANHOLE
S.Do'BSBL - 44NLE CI=i=LL-i-1 BLOX WALL
50.00 APES REMOVAL
N8920'49"W�
PROPERTY
mNER
RAIISn'£D CGW70UR ° SL^ALE 1•= 20' �4210(a
LOT 80
SITE PLAN
GREGOR Y PARK
LG/ HOMES PLAN NO. KETTLE-2159
LOT AREA = 4,666 SF DATE 912712017 PARCEL # LOT 80
HOUSE= 1,588 5
14711 NE 291h Place,11,11
DR/V£WAY= 472 SF 301—e,W.shmgl-98007 DESIGNED CORE ADDRESS 9020 1697H ST. NE
425.885,7977 Fax 425.805 7963
WALKWAYIPAAO = 39 Sf- `DESIGN PROJECT NUMBER
TOTAL= 2,099 SF
ENGINEERING PLANNING • SURVEYING DRAWN CAF 13024L-GRG00
NOTICE
TO PERMITEE AND/OR OWNER
❑ PARTIAL APPROVAL
❑ DO NOT OCCUPY
❑ CORRECTIONS REQUIRED
PERMIT LOT
NUMBER ( (�; #
JOB ADDRESS
❑ NO PERMIT—STOP WORK—OBTAIN PERMIT AND MAKE WORK COMPLY
WITH CURRENT BUILDING/PLANNING CODES.
❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND
PERMIT—STOP WORK. MAKE EXISTING WORK COMPLY WITH APPROVED
PLANS AND PERMIT OR REMOVE IT.
❑ STOP WORK—UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR.
❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED.
❑ WORK NOT READY FOR INSPECTION-$50 REINSPECTION FEE(PER IBC)
MUST BE PAID BEFORE NEXT INSPECTION.
❑ CONTACT INSPECTOR ❑ RECALL FOR INSPECTION
y l
THE ACTIONS OR CORRECTIONS INDICATED ABOVEARE RQUIRED WITHIN DAYS OR PENALTIES
IMPOSED BY LAW MAYBE APPLIED,
FOR INSPECTIONS CALL: 360.403-3417
For questions or to talk to an Inspector,call: 360-403-3551
{J, t"' 'S�'� I I ) / ❑BUILDING DEPT
Inspector Date ❑PLANNING DEPT
CITY OF ARLINGTON
NOTICE
TO PERMITEE AND/OR OWNER
❑ PARTIAL APPROVAL
❑ DO NOT OCCUPY
❑ CORRECTIONS REQUIRED
PERMIT LOT DATE:
NUMBER #
JOB ADDRESS
❑ NO PERMIT—STOP WORK—OBTAIN PERMIT AND MAKE WORK COMPLY
WITH CURRENT BUILDING/PLANNING CODES.
❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND
PERMIT—STOP WORK. MAKE EXISTING WORK COMPLY WITH APPROVED
PLANS AND PERMIT OR REMOVE IT.
❑ STOP WORK—UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR.
❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED.
❑ WORK NOT READY FOR INSPECTION-$50 REINSPECTION FEE(PER IBC)
MUST BE PAID BEFORE NEXT INSPECTION.
❑ CONTACT INSPECTOR \❑ RECALL FOR INSPECTION
THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE RQUIRED WITHIN DAYS OR PENALTIES
IMPOSED BY LAW MAY BE APPLIED.
FOR INSPECTIONS CALL: 360-403-3417
For questions or to talk to an Inspector,call: 360-403-3551
❑BUILDING DEPT
Inspector Date ❑PLANNING DEPT
CITY OF ARLINGTON
{
I+
..
■ I
_ � ■ ■
BUILDING INSPECTION REPORT— MECHANICAL
Permit No. BLD1696
Address: 9020 169th Street NE
Contractor: LGI
Owner: LGI
Date: 1/17/2018
❑ APPROVAL ❑ PARTIAL APPROVAL
❑ CORRECTION ❑ OTHER
APPLIANCE: Gas Piping
A/lo
GAS PIPING: ❑ DRIP LEG: ❑
SHUT-OFF VALVE: ❑ SEISMIC: ❑
PRESSURE TEST: ❑ REGULATOR VENTING: ❑
PIPING SUPPORT: ❑ ACCESS: ❑
% INCH—6 FEET: ❑ MATERIAL: ❑
%- 1 INCH—8 FEET: ❑
1 '/a OR LARGER—10 FEET: ❑
Date: 1/17/2018 INSPECTOR:
7 . CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:9020 169th Street NE Permit#:1696
Parcel#:01166900008000 Valuation:269962.41
OWNER APPLICANT CONTRACTOR
Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC
Address: 1450 LAKE ROBBINS DR STE 430 Address:9026 168th Street NE Address: 11410 NE 124th Street,Ste#103
City,State Zip:THE WOODLANDS,WA 77380 City,State Zip:Arlington,WA 98223 City,State Zip:Kirkland,WA 98034
Phone: Phone:425-785-0797 Phone:360-353-0588
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Single Family Residence CODE YEAR: 2015
STORIES: 2 CONST.TYPE: `/_B
DWELLING UNITS: 1 OCC GROUP: R-3
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110.
S. LE. TA,'NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
a c ed A=:AL-
VG�kSt �� 1
Signature Print Name Date Released By atc
CONDITIONS
ADHERE TO APPROVED PLANS.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
10/24/2017 Building Permit Fee $2,759.38
10/24/2017 Building Plan Review Fee $1,793.60
10/24/2017 Furnace $25.00
10/24/2017 Gas Outlets Base Fee 1 to 5 $10.00
10/24/2017 Mechanical Fee(Enter Fixture Fee) $25.00
10/24/2017 Mechanical Permit Base Fee $25.00
10/24/2017 Park-Community SF $1,662.00
10/24/2017 Plumbing Permit Base Fee $25.00
10/24/2017 Plumbing Permit Fee(Enter Fixture Fee) $168.00
10/24/2017 Processing/Technology Fee $25.00
10/24/2017 State Building Code Surcharge Fee $4.50
10/24/2017 Traffic Mitigation-City $3,355.00
10/24/2017 Water Heater $25.00
Total Due: $9,902.48
Tidal Payment. $9,902.48
Balance Due: $0.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
SETBACKS NOTES:
fROVT 20' ,BUILDING D/MENRWS ARE 70
SrVE 5' FAX O<FOUNDAl1GW
B WAT£R 169TH ST, E REAR 5' ,LWADING WONN AS 006W
- ACTUAL LOCA7IOV MAY VARY
St ,SYOPIF DVPIb£WAY 70 PUBLIC ROAD
•Z T FENCE TO BE INSTALLED PER
8'SFNfiP OYTY OF ARL/NG76 S STANDARD
f0.00'P UC •_%T fENCr 70 BE INSTALLED OV
GKADIEHT SYDE OF BUILDING
UAU CGNNECA S70ft aiANOIUT. PAS
EASEME! COWNECT ROOF AND •COWS7RUCALW ENIRANO F TO BE
o p ' o o �+1 • FOOhNG D➢NNS
INSTALLED PER CITY OF
ARUNGlDV4 F STANDARDS
ILI N89 20'49"W d ° , \ STORM NOTES.-
25. •TESL'INSTALLED PR/OP 70
CONSIRUCAGW
r' o_ •BARE SaLS COWRED Nl1N MULO'I
$ o o OP ANOTHER APPROb£D BIIP
,n 5VO' 20.001 70PS6k PER 01500E BW T513
- - H — ,
s < o (EFT 12'DEP7H)
— 472 •ALL GWS/1£RUNOFF CONNE07£D TO
DglWNAY — — - ° PR/VAX S7W STUB
71 10L •44 SITE SHALL BE STABILIZED f34IOR
20.00 g 10 70 BUILDING PERMIT BEING
1 GARAGE FINALIZED
1.00'ROOD 1 450 e , SITE NOTES:
OWRARAW I \ •770YZINE F007ING DRAINS AND
BUILDING ROO<DRAINS 76 PERMANENT
��aW OURIN£ ST"DRNNA6F SYSTEM PER
T
APPRWD PLAT DRAINAGE FLAN
$ LOT 80 2 H D1S7UR
ON RLE NI7H THE CaINTY.
o Q, g PROPOSED IPESJDENCf o _ -AREA OIL- BANLI�INCLUDES
KETTLE--2159 GARAW R10yr SNARE LOT.
1,5& ^ S LEGEND:
o- BLOW OFF
35.00 ® NO7ER ME7ER
' I « ARE HYDRANT
r 5.00'80L PA AO 39 9r *_ A/R VAC
g I E'X/STING fIIl CATW BANN
O0117WR(TYP.) S O OfANOUT
WA ER
S.00'B519L
O MANHOLE
&g p NOLr T1 I F1 BLOW WALL
50.00 i ,/ TREE REMOVAL
N8920'49"W
ITY O G
RA°ERTY
BUILDIN EPPR(TmP) a 0C'I,
AP F RAKpWED CCW70UP S�"1'=20'
/�
�) °
�Y �! LOT 80
NO CH AU ORIZED I S/TE PLAN
UNLESS OV D BY THE
BUILDIN I SPECTOR - GREGOR Y RA RK
L G/ HOMES PLAN NO. KET7LE-2159
LOT AREA = 4,666 SF DATE 912712017 PARCEL # LOT 80
HOUSE= 1,588 SF 14711 NE291h Pl.,,N101
DRIVEWAY= 472 SF 6e11evue,W.,hi,gt,,98007 DESIGNED CORE ADDRESS 9020 1697H Sr NE
425.885.7B77 FaR 415 885.7963
WALKWAY/pA770 = 39 SF ��DfSIGN PROJECT NUMBER
TOTAL= 2099 SF
ENGINEERING PLANNING • SURVEYING DRAWN CAF 13024L-GRGOO
1 ,ter �. ..;� �. '+Y�; �� ��7.1•.�
y�l`;:»�l•�1 �V1��Lt�B
Permit Information
Date 10/12/2017
Permit Number 1696
Project Name Gregory Park
Applicant Name LGI Homes-Washington,LLC
Applicant Address 9026 168th Street NE
City,State,Zip Arlington,WA 98223
Contact Matt Adams
Phone 425-785-0797
Email matt.adams@lgihomes.com
Permit Type Single Family Residence
Site Address 9020 169th Street NE
Valuation 269962.41
Status Applied
Permit Issued
Permit Expires
Square Feet 2577
Type of Construction/Occupancy Load V-B
Number of Stories 2
Proposed Use New SFR
Assigned To Kristin Foster
Property
Owner
Parcel Address Legal Owner Phone Zoning
01166900008000 9020 169th Street LGI HOMES-WASHINGTON 111 Single Family Residence-
NE LLC Detached
Contractors
Contractor Name Primary Phone Email Contractor License License#
Contact Type
LGI Homes-Washington,Jake Jabusch 360-353- lake.jabusch@lgihomes.co CONTRACTOR (Labor and ILGIHOHL857M
LLC 0588 Industries
Review
Date Type Descri tion I Target Date Completed Date Assigned To Status
10/12/2017 IlResidential Dwelling 10/19/2017 Nmy Rusko ]In Review
10/12/2017 lResidential Dwelling 10/19/2017 1 lKevin Olander In Review
Fees
Fee Description Notes Amount
BuIldIng Permit Fee 322.10.00.00 $2,159.ib
Building Plan Review Fee 345-83.00.00 $1,793.60
Furnace 322.10.00.00 $25.00
Gas Outlets Base Fee 1 to 5 322.10.00.00 $10.0
Mechanical Fee(Enter Fixture Fee) 32210.00 0 $25.0
Mechanical Permit Base Fee 322.10.00.00 $25.0
Park-Community S 345.85.00.001 $1.662.0
Plumbing Permit Base Feel 322.1&00.0q. $25.0
Plumbing Permit Fee(Enter Fixture Fee) 322.10.00.0 14 @$12 $168.0
Processing/Technology Processingrrechnology Fee 341.43.00.02 $25.0
State Building Code Surcharge Fee 386.00,01.00 $4.5
Traffic Mitigation-City 345.85.00.02 $3.355.00.
Water Hcator 322.10.00.00 $25.00
Totaq $9.902.4
Notes
Date Note
10/12/2017 Lot 80-Kettle
Uploaded Files Upload File
Date File Uploaded B
10/12/2017 1:17:02 PM 1696 Site Plan.adf Foster,Kristin x
10/12/2017 1:17:02 PM 1696 Application.pdf Foster,Kristin x
RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
1N City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551(r�
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE,
ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS
OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST
ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING
VERIFICATION MAY BE SUBMITTED PRIOR.
Project Address: Plat:
9020 169th Street NE Gregory Park Lot 80
III Single-family ❑ Duplex 0J Townhouse ❑ Addition Cl; Accessory structure
Proposed Area: 1 s' Floor: 963 2nd Floor: 1196 Garage: 418 Total SF: 2577
Describe Proposal (include cross street):
Application for new single family residence to be located at 9020 169th Street NE. Cross street is 91st,
Valuation:
Owner:
LGI Homes - Washington LLC
_
Address:
9028 168th Street NE City: Arlington State:WA Zip Code:98223
_
Phone: 425-785-0797 Email: matt.adams@lgihomes.com
Applicant: LGI Homes - Washington LLC
Address:
9028 168th Street NE City:Arlington State: WA Zip Code:98223
Phone:
425-785-0797 Email: matt.adams@lgihomes.com
Contractor: LGI Homes - Washington LLC
Address:
9028 168th Street NE City:Arlington State:WA Zip Code:98223
Phone:
425-785-0797 Email: matt.adams@lgihomes.com
Contact Person: Matt Adams License Number:LGIHOHL857MB Expiration: 07/02/2019
W7 IlAte
6/16LP Page 1 of 3
Ztr
�` RESIDENTIAL PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
t3 Bath/Shower Combo (4.0) x Sink (1.5) x 1
91 Shower (2.0) x Lavatory (1.0) x 4
01 Clothes Washer (4.0) x C Water Closet (2.5) x 3
Dishwasher (1.5) x 1 01 Water Heater x 1
141 Hose Bibb (2.5) x 2 Water Heater Model #
ek Other (list)`h x 1 AO Smith HPTU - 50N
Plumbing Section Continued
Proposed Water Piping Size: 3/411 Proposed DWV Material: AB
Proposed Piping Material: PEX Proposed DWV Size: 2"
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
6/16LP Page 2 of 3
I
RESIDENTIAL PERMIT APPLICATION
r Department of Community & Economic Development
O City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551
t NT G
Mechanical Section (continue filling out if mechanical equipment is involved)
Select proposed appliances:
lid Bryant 915SA30040514 95%
Furnace (80+) Model# AFUE
❑ Heat Pump Model# SEER HSPE
❑ AC Unit Model# SEER
❑ Type II Hood D Commercial Cooking Appliance ❑ Hydronic Piping
❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System
01 Fireplace Insert 01 Outdoor BBQ ❑ Storage Tank
I
12.i Freestanding Stove 0; Gas Piping ❑ Other
Gas Piping Information
Not Applicable: 01
Black Steel
Pipe Material: Pipe Size: 1" Total BTU's of all Appliances: 120,000
Distance from Meter to Furthest Appliance: 35'
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper combustion air and venting required for all appliances
• A shut-off is required within 6 feet of all appliances
Applicant Signature: Date: t of 11
Print Applicants Name:
6/16LP Page 3 of 3
Date: 04/10/2026
Perm t#: 1696
Permit Date: 10/12/2017
Review Date: 10/12/2017
Perm it Type: RESIDENTIAL SINGLE FAMILY
Review Type: RESIDENTIAL SINGLE FAMILY
Target Date: 10/19/2017
Scheduled Time 00:00
Com pleted Date: 10/13/2017
Description: Site plan m xts all land use regulations.
Review Status:
Assigned To:
Tim eIn: 00:00
Time O it: 00:00
H curs: 0.0
Property Information
Parcel#: 01166900008000 L GI HOMES -WASHINGTON LLC
LGI HOMES -WASHINGTON LLC 1 450 LAKE ROBBINS DR STE 430
9020 169th Street NE T HE WOODLANDS, WA77380
Zoning: 111 Single Fam iy Residence -
DetachedLot: 80131ock:
Permit#: 1696
Permit Date: 10/12/17
Permit Type: RESIDENTIAL SINGLE FAMILY
Project Nam e Gregory Park
Applicant Nam a LGI Horn cs -Washington, LLC
Applicant Address: 9026 168th Street NE
Applicant, City, State, Zip: Arlington,WA98223
Contact: Matt Adam s
Phone: 425-785-0797
Em al: m at.adam s@lgihom cs.com
Scope of Work: New SFR
Valuation: 269962.41
Square Feet: 2577
Num ber of Stories: 2
Construction Type:
O xupancy G ioup:
ID Code:
Permit Issued: 10/27/2017
Permit Expires:
Form Permit Type:
Status: LASERFICHE
Assigned To: Kristin Foster
Property
Parcel# Address L egal Description O wrier Nam e Ovner Phone Zoning
LGI HOMES-
01166900008000 9 020 169th Street NE WASHINGTON Residence
Single Dam iy
-Detached
LLC
Contractors
Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License#
LGI HOMES- 12951 BELRED CONSTRUCTION Labor and LGIHOHL857MB
WASHINGTON LLC RD#150 CONTRACTOR Industries
Inspections
Date I nspection Type D escription S cheduled Date C om Iieted Date I nspector S tatus
12/08/2017 R20.SFR/DUPLEX 03/07/2018 B UILDING C om Iieted
FINAL
Plan Reviews
Date R eview Type D escription A ssigned To R eview Status
10/12/2017 RESIDENTIAL SINGLE Site plan m e is all land use regulations.
FAMILY
10/12/2017 RESIDENTIAL SINGLE BUILDING
FAMILY
Fees
Fee D escription N otes A m cunt
Building Perm i T able 4-1 $2,759.38
Building Plan Review T able 4-2 $1,793.60
Forced Air Heat f ee per Btu $25.00
Gas Piping/Units E nter#of units $10.00
Mechanical Fee(Enter Fixture Fee) $25.00
Mechanical Base P erm i Fee $25.00
Park-Com m nity SF S ingle Fam iy $1,662.00
Plum hng Base Perm i Fee $25.00
M echanical Com m mial Perm i T able 4-7;Per Unit 1 4 @$12 $168.00
Processing/Technology $25.00
State Surcharge- 1 st DU R esidential- 1 st Unit $4.50
Traffic Mitigation-SF S ingle Fam iy $3,355.00
Wier Heater(Tank) $25.00
Total $9,902.48
Attached Letters
Date Letter D escription
10/24/2017 Building Perm i
Paym acts
Date Paid By D escription P aym a►t Type A ccepted By A m aunt
10/24/2017 LGI Hom cs-Washington,, Check#5764 K ristin Foster $8,108.88
LLC
10/24/2017 LGI Hom 6-Washington,, Check#5763 K ristin Foster $1,793.60
LLC
O utstanding Balance $0.00
Notes
Date Note C reated By:
10/12/2017 Lot 80-Kettle Kristin Foster
Uploaded Files
Date File Nam e
10/27/2017 2736453-1696 Issued Perm i.pdf
10/12/2017 2695696-1696 Application.pdf
10/12/2017 2695697-1696 Site Plan.pdf