HomeMy WebLinkAbout8919 169th Street NE_BLD1689_2026 RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE,
ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BYTWO(2)SETS
OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS, THE APPLICATION MUST
ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING
VERIFICATION MAY BE SUBMITTED PRIOR.
8919 169th Street NE Gregory Park- Lot 72
Project Address: Plat:
®; Single-family L7; Duplex C)I Townhouse 01 Addition ❑ Accessory structure
Proposed Area: 1" Floor: 1076 2nd Floor: 1438 Garage: 380 Total SF: 2894
Describe Proposal (include cross street): Ogle(
Application for newsingle family residence to be located at44?44-16th Street NE. Cross street is 91st
Valuation: ;�TA_"t:3J
Owner: LGI Homes- Washington LLC
Address:
11410 NE 124th St. STE 103 City: Kirkland State:WA Zip Code:98034
_
Phone: 360-353-0588 Email: jake.jabusch@lgihomes.com
Applicant: LGI Homes- Washington LLC
Address:
11410 NE 124th St STE 103 City: State: Zip Code:Kirkland WA 98034
_ .
Phone: 360-353-0588 Email:jake.jabusch@lgihomes.com
Contractor: LGI Homes- Washington LLC
Address:
11410 NE 124th St. STE 103 _ City:Kirkland State:WA Zip Code:98034
Phone: 360-353-0588 Email:jake.jabusch@Igihomes.com
Contact Person:Jake Jabusch License Number:LGIHOHL857MB Expiration: 7/3/2018
6/16LP Page 1 of 3
;j`��` RESIDENTIAL PERMIT APPLICATION
y Department of Community & Economic Development
City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
J Bath/Shower Combo (4.0) x 2 16 Sink (1.5) x 1
C�1 Shower(2.0) x 1 Ej Lavatory (1.0) x 5
❑ Clothes Washer (4.0) x Water Closet(2.5) x 3
Dishwasher (1.5) x 1 9i Water Heater x 1
Ql Hose Bibb (2.5) x 2 Water Heater Model #
F11 Other (list) x 1 AO Smith HPTU-50N
Plumbing Section Continued
Proposed Water Piping Size: 4 Proposed DWV Material: ABS
Proposed Piping Material: PEX Proposed DWV Size: 2"
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
6/16LP Page 2 of 3
�`'� RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
'A City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
C.�
Mechanical Section (continue filling out if mechanical equipment is involved)
Select proposed appliances:
�f Furnace (80+) Model# Bryant 915SA30040S14 AFUE 95%
❑ Heat Pump Model# SEER HSPE
CJl AC Unit Model# SEER
❑I Type II Hood ❑! Commercial Cooking Appliance El Hydronic Piping
0J Boiler ❑I Solid-Fuel Appliance D PV System
Q Fireplace Insert ❑1 Outdoor BBQ ❑I Storage Tank
14 Freestanding Stove BI Gas Piping ❑ Other
Gas Piping Information
Not Applicable: C)
Black Steel
Pipe Material: Pipe Size: 1 Total BTU's of all Appliances: 120,000
Distance from Meter to Furthest Appliance:
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper combustion air and venting required for all appliances
• A shut-off is required within 6 feet of all appliances
WApplicant Signature: Date:
Print Applicants NamC�C � ctf�l
6116LP Page 3 of 3
CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:8919 169th Street NE Permit#: 1689
Parcel#:01166900007200 Valuation:309450.70
OWNER APPLICANT CONTRACTOR
Name:LGI HOMES-WASHINGTON LLC Name:LGI Homes-Washington,LLC Name:LGI Homes-Washington,LLC
Address: 1450 LAKE ROBBINS DR STE 430 Address:9026 168th Street NE Address: 11410 NE 124th Street,Ste#103
City,State Zip:THE WOODLANDS,TX 77380 City,State Zip:Arlington,WA 98223 City,State Zip:Kirkland,WA 98034
Phone: Phone:425-785-0797 Phone:360-353-0588
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Single Family Residence CODE YEAR: 2015
STORIES: 2 CONST.TYPE: `I-B
DWELLING UNITS: 1 OCC GROUP: R-3
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
nd coded ity f Arli ton#3101.
,t.+.!c / fir _
Signature Print Name Date Released By to
CONDITIONS
ADHERE TO APPROVED PLANS.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
10/24/2017 Building Permit Fee $3,076.58
10/24/2017 Building Plan Review Fee $1,999.78
10/24/2017 Furnace $25 00
10/24/2017 Gas Outlets Base Fee 1 to 5 $10.00
10/24/2017 Mechanical Fee(Enter Fixture Fee) $25.00
10/24/2017 Mechanical Permit Base Fee $25.00
10/24/2017 Park-Community SF $1,662.00
10/24/2017 Plumbing Permit Base Fee $25.00
10/24/2017 Plumbing Permit Fee(Enter Fixture Fee) $192.00
10/24/2017 Processing/Technology Fee $25 00
10/24/2017 State Building Code Surcharge Fee $4.50
10/24/2017 Traffic Mitigation-City $3,355.00
10/24/2017 Water Heater $25.00
Total Due: $10,449.86
Total Payment: $10.449.86
Balance Due: S0.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type orinspection being requested,and whether you prefer morning or afternoon
SETBACKS
fRa1/T 20' NOTES.-
\ I f7Nwo C6 vT" •BUILDING DAlENUaVS ARE 70
FA aF fWNDAMail
I ( ) I I REAR 5' •6PAUNG_%ONN AS DIE N
I I A07VAL LON7JaV MAY VARY
1 PRO-ERTY ( •&WE DRI4£WAY 70 PUBLIC ROAD
CWNER I I •RLT FEN6r 70 BE INSTALLED PER
____ (T)P.) aTY OF ARL/NG7a&SrANDARD
L - - - -' - - - - L- - - - - •mirfEN(rTOBE/NSTAUMQV
N89 20 49"W WA90VT S70E alp BUILDING
- PARM
— — — — — — 45.00 �I •aWS7RUCnaV&NANa l 7O BE
- - - � � r - - - - - INSTALLEDPE]Pa7YA-
TOP 450.0 5.00 B519L
3.0 I I ARL/NGW9 STANDARDS
TOE 447.0 EXLSANG
I I cm7UUR(m) STORM NOTES.-
5�,ma •7M INS TAL LED PRaP 7D
010'BSRZ I COVS7PUC77aV
' WALL/bRA/N I I •BARE SaLS COWRED W N MULal
>0.00
E WALLNT <PAAO 12 SF I I aP ANOND?APPROWD 6WP
4WSaL PER NWX NP 7513
--- (EFF 12"lf)°7H)
5 r ,75 Lao -•ALL aVS77E RUNaT COINNENM TO
LOT 72 PR/VA1E S7a4A/STUB
1.00'ROAD'OV£RH ,
��R£SIDENQ� I 577E MAU BE STABILIZED PROW
` 10 BU/LL7VNG PERMdIT BE]NG
PAUX-2514 GARAGE R/GYIT
TOP 450.0 =� I HNAUZED
3.0 TOE 447.0 1,67919r $ p0 � I SITENOTES.-
i �
16 ^ I •A WRINE fVOANG DRAINS AND
0� o I RooF DRAINS 70 PERMANENT
o GARAX = I SMW DRNNA6r SYSTEM PER
APPROb0 PLAT DRAINAGE PLAN
o BUILDING-` I aV RLE N►7H 7HE CWNTY.
I = aUn/NE I •AREA ac D1S7VRM6r INaUDES
TOP 00 450.0 - I SNARE LOT.
3.0 TOE 4447.0 � g 24� 4 ' LEGEND.
°
- - - - - - - � °
� 11.00�c r-- e I L — — � BLOW aT
f0.00'Pou - V1 9r 26.A0 —— — ® WAIE]P ME7DP
I/AU7Y DRIWW y
EASWDvr 20.00'BSBL g roRANT
AIR YA
A
1°
— — — — 02 CA7aI BAMN
N8 20'49"W °: i O aamaIir
g ° ° L00 ° MANHGY£
1 Y _ r i ecaar wAct
AL i�
i WA I2 - NEE REMOVAL
GLWNECT RW AAD WA
8"WA7ER
CW$Cnav f00
8 .2w N 1 s 20' (7111M
r,A<E '=
\� 169TH T, NE
LOT 72
�- � - SITE PLAN
GREGOR Y RARK
LGI HOMES PLAN NO. PALIX-2514
LOT AREA = 4,J20 5F DATE 912812017 PARCEL # LOT 72
HOUSE= 1,679 SF
1471 I NE 291h Ploe#701
DRIVEWAY= 471 Sr Bellevue,W.shmgf-98007 DESIGNED CORE ADDRESS 8919 1697H Sr NEC
425.995.7077 Fax 425.BB5.7963
WALKWAY/PAAO = 12 SF �B��es' N PROJECT NUMBER
TOTAL= 2,162 Sr
ENGINEERING • PLANNING • SURVEYING DRAWN CAF 13024L-GRG00
CIT OF
ARLINGTON
• % 238 N. OLYMPIC AVE -ARLINGTON, WA, 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:8919 169th Street NE
Parcel#:01166900007200 Permit#: 1689
OWNER APPU11CANT Valuation:309450.70
Name:LGI HOMES-WASHINGTON LLC Name: LGI Homes- CONTRACTOR
Address: 1450 LAKE ROBBINS DR STE 430 Address=9026 168th Street1NEon,LLC Name:LGI Homes-W
ashington.LLC
City,State Zip:THE WOODLANDS,TX 77380 City,State Zip: g Address: 11410 NE 124th Street,Ste#103
Phone:425-785-0797 ,WA 98223
Phone: City,State Zip:Kirkland,WA 98034
Arlington,
MECHANICAL CONTRACTOR Phone:360-353-0588
Name:
PLUMBING CONTRACTOR
Address: Name:
City,State,Zip: Address:
Phone: City,State,Zip:
LIC#: EXP: Phone:
JOB DESCRIPTION LIC#:
EXP:
PERMIT TYPE: Single Family Res5en
CODE YEAR: 2O 1 S
STORIES: 2
DWELLING UNITS: 1 CONST.TYPE: `J-B
BUILDINGS: OCC GROUP: R-3
OCC LOAD:
PERMIT APPROVAL,
I AGREE TO COMPLY WITH CITY AND STATE LAWS R EGUI,ATINCi CONSTRIIC'fIUN AND IN UOING THE WORK Al1TIlORIZ..ED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID,
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
nd coded it )f Arli ton#3101.
Signature Print Name
Date Released By
CONDITIONS ate
ADHERE TO APPROVED PLANS.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
Date Description PERMIT FEES
10/24/2017 Building Permit Fee
Fee Amount
10/24/2017
Building Plan Review Fee $3,07ti 58
10/24/2017 Furnace
10/24/2017 Gas Outlets Base Fee 1 to 5 $1,999 78
10/24/2017 Mechanical Fee(Enter Fixture Fee) $25.00
10/24/2017 Mechanical Permit Base Fee $10 00
10/24/2017 Park-Community SF $25 00
10/24/2017 Plumbing Permit Base Fee $25.00
10/24/2017 Plumbing Permit Fee(Enter Fixture Fee) $1,$22 00.00
10/24/2017 Processing/Technology Fee 192
10/24/2017 State Building Code Surcharge Fee $ 5.00
10/24/2017 Traffic Mitigation-City $25.00
10/24/2017 Water Heater $4.50
$3,355.00
$25.00
Total Due:
$10,449.86
'fugal Payment:
$10.449.96
Balance Due:
50.00
CALL FOR INSPECTIONS BUILDING(360)403-3417
When calling for an inspection Please leave the following information:
Permit Numher.'rype of Inspection being requested.and whether you prefer morning or afternoon
SE NOTES.
ITY OF L� _ 7�'OTTRCE -
GiYT 20 .BUILDING DIMENSYANS ARE 70
BUILDING PA N - p
TBACKS
SYDE 5' FAarOFFOUNDAXW
A P P R - I I REAR 5 •6R"NG S�/ONV AS DES W
1
I � I I ACTUAL LOCATION MAY VARY 1 B ( •SLOPE UR/f/FWAY 70 PUBLIC ROAD
�N�
I I •RLT FENar TO BE INSTALLED PER
(Tw.)6� dTY OF ARL/NGXIV�STANDARD
ARITB�IAU E --- - - - - - L- - - - - •KT FENCE 70BE INSTALLED CW
UNLE V8920'49V GI4ADIENT SYD£OF BUILDING
BUILDING INSP 45.00 PARM
i •CLWSIRUCACW EN7RANCLF TO BE
TOP 450. 5.— — —� r —— — — — /NNTALLM POP C17Y CIS
3.0 00'BSBC ARL/NG OV1 9 STANDARDS
TOE 44ZO I I I EX/SANG
$ CM70UR(TYP.) STORM NOTES.•
•MW INSTALLED PRICIP TO
�—800 BSK ,SOLI'BS&� � I 01667RUCnCW
10.00'WALLIVRNN I •BARE SQZS COVfWED N17H MilDY
EASEMENT I--"PA AO 12 SF� -- 0?AN07HOP APpROVfD BMP
•TA°SOYL PER N5VOf BMP 7513
5.00 \ - - 010' (fFF 12 DEP7H)
moo I •ALL GWYTF RUNOFF C0VNECMV TO
LOT 72 AWVA7E STCI'PM SW
C 1.00'ROTOR 0WRHAN -- � 5, � I •27E-WALL BE STABILIZED PR/U?
PROPa\ PAL/X-2514 WAX R/GYlT �, I TO BU/LA�NG PE]PA//T BEING
TOP 450.0 a ANAL/ZED
3.0 1,679fSJ� $ p ^ I
TOE 447.0 I p SITE NOTES:
f i V :p'� I •7l6W7lJNE FOOLING DRAINS AND
p' GARAGE p I Row DRAINS 1D PERMANENT
p = I ST0YPA/DRAINAGE SY57DM POP
APPROVED RAT DRA/NAGLF PLAN
o p BUILDING I CW FILE W7H 7HE CaINTY.
J Z OUTLINE I •AREA OF D/S7URBANCLc*INCLUDES
3.0 TOp.450.0 24.00 I
D V77RE LOT.
TOE 447.0400' LEGEND:
.,-, j
- - - � J $
nabs �—_ ° L — — a— Bcow a�F
fo.Do'Pueu6l --- ----UnLIn4P -7—26.00 — — — ® WA7M METER
EASOIIOVT 1 Op'B �y g fUPE HYDRANT
I
1 � � AIR VAC
_ m1 CAAW BAMN
i1/8 20'49OW °, i O CLEANOIUT
R ° 45.00 • e O
a d d a MANHOLE
Q4
4d ® BLOT WALL
COWNECT ROIAF AND 7!'D? 12 � 1REL�REMOVAL
F00170ARK 8'WA7ER
c! ECnav +00
oC r 2o17
8'SL71ERl
Sx'ALE 1'=20' 2l V
169TH T.V NE LOT 72
Q \ s SITE PLAN
GREGOR Y RA RK
LGI HOMES PLAN NO. PALIX-2514
LOT AREA = 4„320 SF DATE 912812017 PARCEL # LOT 72
HOUSE= 1,679 SF 14711 NE 29r6 Pl—,#70'
DRIVEWAY= 471 SrCaE Mlevue,W-hlnBbn 91007 DESIGNED CORE ADDRESS 8919 1897H Sr NE
WALKWArIPATIO = 12 SF 425.BB5.7B77 Fax d25.BB5.7963 DESIGN PROJECT NUMBER
TOTAL= 2,162 SF
ENGINEERING • PLANNING • SURVEYING DRAWN CAF 13024L—GRG00
'� ;-r
,. , ,
.. :� 'i
Permit Information
Date 10/12/2017
Permit Number 1689
Project Name Gregory Park
Applicant Name LGI Homes-Washington,LLC
Applicant Address 9026 168th Street NE
City, State,Zip Arlington,WA 98223
Contact Matt Adams
Phone 425-785-0797
Email matt.adams@lgihomes.com
Permit Type Single Family Residence
Site Address 8919 169th Street NE
Valuation 309450.70
Status Applied
Permit Issued
Permit Expires
Square Feet 2894
Type of Construction/Occupancy Load V-B
Number of Stories 2
Proposed Use New SFR
Assigned To Kristin Foster
Property
Owner
Parcel Address Legal Owner Phone Zoning
01166900007200 8919 169th Street LGI HOMES-WASHINGTON 111 Single Family Residence-
NE ILLC Detached
Contractors
Contractor Name Primary Phone Email Contractor License License#
Contact Type
ILGI Homes-Washington. 360-353- (Labor and
ILLC Jake Jabusch 0588 ake.jabusch@Igihomes.co CONTRACTOR (Industries I-GIHOHL857M
Review
Date Type Description I Target Date Completed Date Assigned To I Status
10/12/2017 lResidential Dwelling 10/19/2017 ikmy Rusko 111n Review
10/12/2017 lResidential Dwelling 10/19/2017 lKevin Olander IIn Review
Fees
Fee Description Notes Amount
Building Permit Fee 322.10.00.01 $3,076.58
Building Plan Review Fee 345,83,00 $1$1,999.78
Furnace322.10.00.0 $25.00
Gas Outlets Base Fee 1 to 322.10.00.0 $10.00
Mechanical Fee(Enter Fixture Fee) 322.10.00.0 $25.00
Mechanical Permit Base Fee 322.10.00.0 $25.00
Park-Community SF 345.85.00.0 $1,662.00
Plumbing Permit Base Fee 322.10.00.0 $25,001
Plumbing Permit Fee(Enter Fixture FeeI 322.10.00.0q 16 @$12 $192.0
Processing/Technology Fee 341.43.00.021 $25.0
State Building Code Surcharge Fee 386.00.01.0 $4.5
Traffic Mitigation-Ci 345.85.00.021 $3,355.0
Water Heate 322.10.00.Oq $25.0
Total $10,449.8
Notes
Date Note
10/12/2017 Lot 72-Palix
Uploaded Files Upload File
Date File Uploaded B
10/12/2017 9:42:27 AM 1689 Site Plan.Pdf Foster,Kristin x
1(1/12/2017 9:42:27 AM 1689 ApgRggjon.pdf Foster,Kristin x
RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE,
ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS
OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST
ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING
VERIFICATION MAY BE SUBMITTED PRIOR.
Project Address:
8919 169th Street NE Plat: Gregory Park- Lot 72
a Single-family ❑I Duplex Q Townhouse ❑ Addition Eli Accessory structure
Proposed Area: 1 sc Floor. 1076 2nd Floor: 1438 Garage: 380 Total SF: 2894
Describe Proposal (include cross street): 011ef
Application for new single family residence to be located at,9'924 6th Street NE. Cross street is 91st
Valuation: •�0
owner:
LGI Homes- Washington LLC
_
Address:
11410 NE 124th St. STE 103 City: Kirkland State:WA Zip Code:98034
_ _
Phone: 360-353-0588 Email: lake.jabusch@lgihomes.com
Applicant: LGI Homes- Washington LLC A
Address:
11410 NE 124th St STE 103 City: Kirkland State: WA Zip Code:98034
Phone:
360-353-0588 Email:jake.jabusch@lgihomes.com
Contractor: LGI Homes- Washington LLC
Address:
11410 NE 124th St. STE 103 City:Kirkland State:WA Zip Code:98034
Phone: 360-353-0588 Email:jake.jabusch@lgihomes.com
Contact Person:Jake Jabusch License Number:LGIHOHL857MB Expiration: 7/3/2018
VX7 110
6/16LP Page 1 of 3
j 1 �: �
�` °� RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
��l O City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
6 Bath/Shower Combo (4.0) x 2 [!j Sink (1.5) x 1
f�j Shower (2.0) x 1 [El Lavatory (1.0) x 5
❑' Clothes Washer (4.0) x Water Closet (2.5) x 3
pJ Dishwasher (1.5) x 1 a Water Heater x 1
9I Hose Bibb (2.5) x 2 Water Heater Model #
Fib Other (list) x 1 AO Smith HPTU-50N
Plumbing Section Continued
Proposed Water Piping Size: 3/411 Proposed DWV Material: ABS
Proposed Piping Material: PEX Proposed DWV Size: 211
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
6/16LP Page 2 of 3
RESIDENTIAL PERMIT APPLICATION
Department of Community& Economic Development
C,SO City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403 3551
Mechanical Section (continue filling out if mechanical equipment is involved)
Select proposed appliances:
141 Furnace (80+) Model# Bryant 915SA3004OS14 AFUE 95%
01 Heat Pump Model# SEER HSPE
❑ AC Unit Model# SEER
❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping
❑ Boiler Q Solid-Fuel Appliance 01 PV System
01 Fireplace Insert Q; Outdoor BBQ Q Storage Tank
Freestanding Stove Gas Piping Q Other
Gas Piping Information
Not Applicable: ❑
Black Steel
Pipe Material: Pipe Size: 1" Total BTU's of all Appliances: 120,000
Distance from Meter to Furthest Appliance: 5
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper combustion air and venting required for all appliances
• A shut-off is required within 6 feet of all appliances
Applicant Signature: Date: 10/11
Print Applicants Nam�/_
6116LP Page 3 of 3
4o-oaao
i
N
C
ml N�
3 �
r
a
0
rt
aoaoo �aoaoo
f JI.
(1 N
y^ �
y _
- vvs:s -`sz -
N
.r,
z Received
rC
OCT 2017
�IKN
I� Den Cffl n Dm"III 6YIItle1 LGI HOMES Job Number Sheel TNe
BMC1+�007BM AvmNe NEl EreiMl N'AIA7�01 ]ab Name/Motlel 2519-A RF GL DeelBner DAN C. TRD$S LAYOUT
■■ oe�e:as7�uoe
1�0.IfIN1! :W_^41R. � Mw hem Adduu: Date 5/8/2017
yh ..
Job Truss Truss Type ply 1113114011IFS11114ARF
2514-A Al Common Supported Gable 1 1
Job Reference lfootlonab �_
BMC.EVERETT,WA 98205-3212 8.000 s Jul 15 2010 MiTek Industries,Inc. Mon May 08 15.14 30 2017 Page 1
ID:migzTLjh7H1sSQCFVTnRO6zlaVJ-4 w69Bygt_DEkReKNDzpGIRjjCCIbCBfrGNkjgziVet
8-3 0 4 18.60 17-6-0
1.0.0 8.3.0 8-3.0 i 1-0 0 '0
Scale:3/8"=l'
45=
/ F
5.00 F12 E G
S T U V
D H
T
C T
T
B 171 J
jb K �d
�} 3x4= R Q p 0 N M L 3x4=
18-9-0
16.6.0
' 1641.0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 25.0 Plate Grip DOL 1.15 TC 0.11 Vert(LL) 0.00 J n/r 180 MT20 185/148
(Roof Snow--25.0) Lumber DOL 1.15 BC 0.06 Vert(CT) 0.00 K n/r 180
TCDL 7.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 J n/a n/a
BCLL 0.0 ' Code IRC2015/713I2014 (Matrix) Weight:57 lb FT=10%
BCDL 10.0
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No.2 MiTek recommends that Stabilizers and required cross
bracing be installed during truss erection,in accordance
With Stabilizer Installation guide.
REACTIONS. (lb/size) B=162/16-6-0 (min.0-2-8),J=162/16-6-0 (min.0-2-8).0=159/16-6-0 (min.0-2-8).P=169116-6-0 (min.0-2-8),0=164116-6.0 (min.0.2-8)
,R=182/16-6-0 (min.0-2-8),N=169/16-6-0 (min.0-2-8).M=164/16-6-0 (min.0-2-8),L=182/16-6-0 (min.0-2-8)
Max Horz B=-46(LC 13)
Max UpliftB=-22(LC 8),J=-24(LC 9),P=-25(LC 12),Q=-25(LC 12),R=-23(LC 12),N=-24(LC 13),M=-25(LC 13),L=-23(LC 13)
Max GravB=178(LC 18),J=178(LC 18),0=159(LC 1),P=213(LC 19),Q=170(LC 19),R=182(LC 1),N=213(LC 20),M=170(LC 20),L=182(LC 1)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-13=0/41,B-C=-56/35,C-D=-39/39,D-S=-35/60,S-T=-16/61,E-T=-16/64,E-F=-43/106,F-G=-43/106,G-U=-16/64,U-V=-16/61,H-V=-35/60,
H-1=-35/35,I-J=-40/19,J-K=0/41
BOT CHORD B-R=-7/53,Q-R=-7/53,P-Q=-7/53,O-P=-7/53,N-0=-7/53,M-N=-7/53,L-M=-7/53,J-L=-7/53
WEBS F-0=-120/6,E-P=-173/92,D-Q=-131/57,C-R=-137/78,G-N=-173/92,H-M=-131/57,I-L=-137/78
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-3-0,Exterior(2)2-3-0 to 5-3-0,Corner(3)
5-3-0 to 8-3-0,Exterior(2)11-3-0 to 14-3-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C
for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see
Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
7)All plates are 2x4 MT20 unless otherwise indicated.
8)Gable requires continuous bottom chord bearing.
9)Gable studs spaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11)"This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
2-0-0 wide will fit between the bottom chord and any other members.
12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 22 lb uplift at joint B,24 lb
uplift at joint J,25 lb uplift at joint P,25 lb uplift at joint Q,23 lb uplift at joint R,24 lb uplift at joint N,25 lb uplift at joint M
and 23 lb uplift at joint L.
13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2
and referenced standard ANSI/TPI 1.
JOID Truss Tlruns ype Qly y LGI HOMES 2514-A RF 1
2514-A A2 Common 1 1 JII
Job Reference loptioneQ
IRMC,EVERETT,WA 982054212 8.000 s Jul 15 2018 M1Tak Industries.Inc. Mon May OB 15:14:31 2017 Page 1
tB ID:migzTLjh7H1sSQCFVrnRO6ziaVJ-YAUUN%ySeHL4MbCWxwU2oz_sTcQDKe?il rzHFGzIVBs
4-7-4 8-3 0 11-10-12 164-0 �7-8-0
140-0 4-7-4 3 7-12 3.7--12 1 4-7.4 1 1-0-0 '
Scale:3/8"=1'
4x5=
D
5.00 12
2x4
J K L M 2x4
C E
I N
B F
H
3x6= 3x6=
WO=
18-9-0 18-9-0
1 83-0 16-6-0
83-0
LOADING(Ps25 o SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL(Roof Snow=25.0) Plate Grip DOL 1.15 TC 0.24 Vert(LL) -0.09 F-H >999 240 MT20 185/148
TCDL 7.0 Lumber DOL 1.15 BC 0.55 Vert(CT) -0.19 F-H >999 180
BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(CT) 0.03 F n/a n/a
BCDL 10.0 Code IRC2015/TP12014 (Matrix) Weight:56 lb FT=10%
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 4-9-6 cc purlins.
BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing.
WEBS 2x4 HF No.2 MiTek recommends that Stabilizers and required cross
bracing be installed during truss erection,in accordance
with Stabilizer Installation uide.
REACTIONS. (lb/size) B=752/0-5-8 (min.0-1-8),F=752/0-5-8 (min.0-1-8)
Max Horz B=-46(LC 13)
Max UpliftB=-49(LC 12),F=-49(LC 13)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-B=0/42,B-1=-1234/107,C-1=-1197/120,C-J=-939/71,J-K=-927/73,D-K=-891/82,D-L=-891/82,L-M=-927/73,E-M=-939/71,E-N=-1197/120,
F-N=-1234/107,F-G=0/42
BOT CHORD B-H=-70/1093,F-H=-53/1093
WEBS D-H=0/449,E-H=-353/107,C-H=-353/107
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 5-3-0,Exterior(2)
5-3-0 to 8-3-0,Interior(1)11-3-0 to 14-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C
for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1
3)Unbalanced snow loads have been considered for this design.
4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
2-0-0 wide will fit between the bottom chord and any other members.
8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 49 lb uplift at joint B and 49 lb
uplift at joint F.
9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
i �
Job Truss y e y L 4 HOMES 2514-A R
__]
2514A B1 GABLE 1 1
Job Reference(Oaionaq
BMC.E�WFT7,WA 982054212 8,000 s Jul 15 2016 MIT&InduA603 Inc. Mon May 08 15.14 31 2017'Pag I
ID:migzTLjh7H 1 sSQCFVTnRO6zlaVJ-YAUUNXySeHL4MbCW&02ozjvcPgKeopg,g7,t{FGzIV8s
1(� 11-9-0 15-3-0 23-" �1'G
1r01 11-9 0 3 6-0 I B-3-0 11-
Scale=1:44.8
4x5=
- � 1
4x12=
5.00 F12
G K
V WM
E L
Dcc
J
C H
U T X
F
B R N
O
0
Q
3V 3x6 3x4= P 3x6=
T S
18-9-0 18-9-0
i 15-3-0 23-6-0
153-0 8-3-0 �
Plate Offsets((Y)— IM.0-5-12.Ed-gel
LOADTCLL (ps25 0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
(Roof Snow=25.0) Plate Grip DOL 1 15 TC 0.79 Vert(LL) -0.12 N-P >999 240 MT20 185/148
TCDL 7.0 Lumber DOL 1.15 BC 0.59 Vert(CT) -0.25 N-P >806 180
BCLL 0.0 " Rep Stress Incr YES WB 0.07 Horz(CT) 0.03 N n/a n/a
BCDL 10.0 Code IRC2015/TP12014 (Matrix) Weight:95 lb FT=10%
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2"Except' TOP CHORD Structural wood sheathing directly applied or 4-1-7 cc purlins.
T2:2x6 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
BOT CHORD 2x4 HF No.2 JOINTS 1 Brace at Jt(s):J,H
WEBS 2x4 HF No.2 i MiTek recommends that Stabilizers and required cross
OTHERS 2x4 HF No.2 bracing be installed during truss erection,in accordance
with Stabilizer Installation guide.
REACTIONS. (lb/size) B=252/7-5-8 (min.0-2-3),S=-210/7-5-8 (min.0-2-3),T=314/7-5-8 (min.0-2-3),N=781/0-5-8 (min.0-1-8),R=960/7-5-8 (min.0-2-3)
Max Horz B=64(LC 12)
Max UpliftB=-11(LC 12),S=-21O(LC 1),T=-39(LC 12),N=-58(LC 13)
Max GravB=267(LC 19),T=314(LC 1),N=781(LC 1),R=960(LC 1)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-B=0/41,B-U=-210/0,C-U=-159/8,C-D=-193/28,D-E=-188/44,E-V=-198/65,G-V=-163/68,G-1=-176/90,1-K=-175/92,K-W=-173/72,
M-W=-177/68,M-X=-1078/76,N-X=-1168/52,N-0=0/42,F-R=-1019/131,F-H=-959/121,H-J=-947/116,J-L=-921/110.L-M=-884/97
BOT CHORD B-T=0/161,S-T=0/161,R-S=0/161,Q-R=0/983,P-Q=0/983,N-P=0/989
WEBS I-J=-70/17,G-H=-84/38,E-F=-162/57,D-S=-115138,C-T=-199/75,K-L=-96/36,M-P=0/360
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-0-0,Interior(1)2-0-0 to 8-9-0,Exterior(2)
8-9-0 to 11-9-0,Interior(1)14-9-0 to 21-6-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C
for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see
Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSVTPI 1.
3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
7)All plates are 2x4 MT20 unless otherwise indicated.
8)Gable studs spaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
2-0-0 wide will fit between the bottom chord and any other members.
11)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 11 lb uplift at joint B,210 lb
uplift at joint S,39 lb uplift at joint T and 58 lb uplift at joint N.
12)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2
and referenced standard ANSI/TPI 1.
13)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
russ cuss Type y L S251"RF
3
2514-A B2 Common Girder 1 Job Reference[optional)
o
BM ,EVERETT.WA 98205.3212 8.000 s Jul 15 2016 Miiak Indus9w5,Inc..Mon May 08 15:14:3J 2017 Pn 1
18-9-0 18-9-0 ID:migzTLjh7H 1 sSOCFVTnR06zIaVJ-UZbFnD�AvbobvMv2LXVbU0387P4koQ_SYfcOKttrl9�q
4-1-11 7-2-12 11&0 16-3.4 19-4-5 23-6-0
4-1-11 3-1-1 r 4.6.4 4 6 4 3.1-1 I 4-1-11
Scale=1:40.6
4x5=
D
5.00 V2
6x8 6x8
C M N E
3x6 3x6
B F
A G
oI0�1 to �o
P L J I H Q R S T U V W X Y
0 K 4x6=
4x6— 3x10 II 12x12— 8x12= 12x12= 3x10 II
18-9-0 18-9-0 18-9-0
alOrb 12 2-6-12 4-1-11 16-3.4 19 4 5 22-Cr12 23 8 0
l 2 0-0 1 1 41 3 1-t 4 6 4 4-6�4 3 1-1 3 2-7 0-11 4'
_Plate Offsets(X,YI— IJ:0-6.0.04.81
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL 25.0 Plate Grip DOL 1.15 TC 0.42 Vert(LL) -0.10 I-J >999 240 MT20 185/148
(Roof Snow=25.0) Lumber DOL 1.15 BC 0.62 Vert(CT) -0.17 I-J >999 180
BCDL 7BCLL .0 Rep Stress Incr NO WB 0.60 Horz(CT) 0.02 G n/a n/a
BCDL 10.0 Code IRC2015/TPI2014 (Matrix) Weight:340 lb FT=10%
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 5-11-0 oc purlins.
BOT CHORD 2x6 DF SS BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 HIP No.2
REACTIONS. (lb/size) A=1702/0-5-8 (min.0-1-8),G=6544/0-5-8 (min.0-2-5).K=13263/0-5-8 (min.0-4-11)
Max HorzA=-58(LC 28)
Max UpliftA=-92(LC 10),G=-350(LC 11),K=-668(LC 10)
Max GravA=1745(LC 16),G=6566(LC 17),K=13263(LC 1)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-B=-68/1146,B-C=-213/4463,C-M=-3399/210,D-M=-3387/223,D-N=-3357/213,E-N=-3427/200,E-F=-8639/481,F-G=-11670/629
BOT CHORD A-O=-1009/127,O-P=-1009/127,L-P=-1009/127,L-Q=-1009/127,Q-R=-1009/127,K-R=-1009/127,K-S=-4084/273,S-T=-4084/273,J-T=-4084/273
,J-U=-377/7963,U-V=-377/7963,I-V=-377/7963,I-W=-549/10700,H-W=-549/10700,H-X=-549/10700,X-Y=-549/10700,G-Y=-549/10700
WEBS D-J=-103/2310,E-J=-5815/353,E-1=-220/4900,F-1=-3134/196,F-H=-94/2547,C-J=-424/8570,C-K=-7934/426,B-K=-3615/220,B-L=-105/2758
NOTES-
1)Special connection required to distribute bottom chord loads equally between all plies.
2)3-ply truss to be connected together with 10d(0,131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-7-0 oc.
Bottom chords connected as follows:2x6-3 rows staggered at 0-4-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc,Except member E-1 2x4-2 rows staggered at 0-4-0 oc.
3)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)
section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
4)Wind:ASCE 7-10;Vult=11Omph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;
enclosed;MWFRS(envelope)automatic zone;cantilever left and right exposed;end vertical left and right exposed;
Lumber DOL=1.33 plate grip DOL=1.33
5)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1
6)Unbalanced snow loads have been considered for this design.
7)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
2-0-0 wide will fit between the bottom chord and any other members.
10)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 92 lb uplift at joint A,350 lb
uplift at joint G and 668 lb uplift at joint K.
11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2
and referenced standard ANSI/TPI 1.
12)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)1637 lb down and 86
lb up at 0-6-12,1630 lb down and 93 lb up at 2-6-12,1630 lb down and 93 lb up at 4-6-12,1630 lb down and 93 lb up
at 6-6-12,1630 lb down and 93 lb up at 8-6-12, 1630 lb down and 93 lb up at 10-6-12. 1630 lb down and 93 lb up at
12-6-12,1630 lb down and 93 lb up at 14-6-12,1630 lb down and 93 lb up at 16-6-12.1630 lb down and 93 lb up at
18-6-12,and 1630 lb down and 93 lb up at 20-6-12,and 1633 lb down and 90 lb up at 22-6-12 on bottom chord. The
design/selection of such connection device(s)is the responsibility of others.
I
JOD Truss Truss Type uiy ES2514-ARF
2514-A C1 Common Supported Gable 1 1
Job Reference LoplEonab
SM EVERETT,1 88 212 8.000 s Jul 15 2016 Mi I ek Indusum,Ina Mon May 00 15:14355 20177 Page 1
ID:migzTLjh7H 1 sSQCFV rnRO6ziaVJ-Rx)?Cu?zPMWgDVNiAmZ?zp8Ys0umG000?YSVPlzIV8(
-1181' 20-0-0 40-0-0 41-0 0
1-0-0 20-0-0 20-0-0 1-0-
Scale=1:73.7
5.00 12 4x5=
L M
3x4 5-� K
J N 3x4
H O
G P Q
F R
E 6 S
D $ 7 6 T
AO 8T1 3 6 4 5 S S STV AP
2
0
3x4= AN AM AL AK AJ Al AH AG AF AE AD AC AB AA Z Y X 3x4=
5x6=
18-9-0
40-0-0
4
Plate Offsets(X.Y)-- IP:0+0.O:tk0.g1 f4F:0-3-0,0-3A1
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) (/deft L/d PLATES GRIP
TCLL 25.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL) -0.00 V n/r 180 MT20 185/148
(Roof Snow--25.0) Lumber DOL 1 15 BC 0.07 Vert(CT) 0.00 W n/r 180
TCDL 7.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.01 V n/a n/a
BCLL 0.0 Code IRC2015/TPI2014 (Matrix) Weight:198 lb FT=10%
BCDL 10.0
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No.2 WEBS 1 Row at midpt L-AF
ITek recommends that Stabilizers and required cross
bracing be installed during truss erection,in accordance
with Stabilizer Installation guide.
REACTIONS. (lb/size) V=216/40-0-0 (min.0-3-12),AF=160/40-0.0 (min.0-3-12),AG=168/40-0-0 (min.0-3-12),AH=168/40-" (min.0-3-12).AI=168140-0-0
(min.0-3-12),AJ=169/40-0.0 (min.0-3-12),AK=164/40.0-0 (min.0-3-12),AL=185/40-0-0 (min.0-3-12),AM=101/40-0-0 (min.0-3-12),
AN=326140.0-0 (min.0-3-12),AE=168/40-0-0 (min.0-3-12),AD=168/40.0-0 (min.0-3-12),AC=168/40-0-0 (min.0-3-12),AB=169/40-0-0
(min.0-3-12),AA=164/40-0.0 (min.0-3-12),Z=185/40-0-0 (min.0-3-12),Y=101/40-0-0 (min.0-3-12),X=326/40-0-0 (min.0-3-12),
B=216/40-0-0 (min.0-3-12)
Max Horz B=-105(LC 13)
Max UpliftV=-7(LC 9),AG=-20(LC 12),AH=-26(LC 12),AI=-24(LC 12),AJ=-24(LC 12),AK=-24(LC 12).AL=-26(LC 12),AM=-16(LC 12),AN=-45(LC
12),AE=-18(LC 13),AD=-27(LC 13),AC=-24(LC 13),AB=-24(LC 13),AA=-24(LC 13),Z=-26(LC 13),Y=-16(LC 13).X=-45(LC 13).
B=-6(LC 13)
Max GravV=216(LC 20),AF=169(LC 25),AG=246(LC 19),AH=243(LC 19),AI=214(LC 19),AJ=169(LC 1),AK=164(LC 19),AL=185(LC 1),
AM=101(LC 19),AN=326(LC 1),AE=246(LC 20),AD=243(LC 20),AC=214(LC 20),AB=169(LC 1),AA=164(LC 20),Z=185(LC 1),
Y=101(LC 20),X=326(LC 1),B=216(LC 19)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-B=0/41,B-AO=-118/38,C-AC=-108/67,C-D=-86/56,D-E=-64/65,E-F=-53/80,F-G=-39/94,G-H=-38/107,
H-1=-29/110,I-J=-48/136,J-K=-58/174,K-L=-66/214,L-M=-66/214,M-N=-58/174,N-0=-48/136,
O-P=-29/110.P-Q=-38/107,Q-R=-35/82,R-S=-36/55,S-T=-33/29,T-U=-55/14,U-AP=-67/41,V-AP=-87/21,
V-W=0/41
BOT CHORD B-AN=-25/112,AM-AN=-25/112,AL-AM=-25/112,AK-AL=-25/112,AJ-AK=-25/112,AI-AJ=-25/112,
AH-AI=-25/112,AG-AH=-25/112,AF-AG=-25/112,AE-AF=-25/112,AD-AE=-25/112,AC-AD=-25/112,
AB-AC=-25/112,AA-AB=-25/112,Z-AA=-25/112,Y-Z=-25/112,X-Y=-25/112,V-X=-25/112
WEBS L-AF=-129/0,K-AG=-206/88,J-AH=-203/80,I-AI=-174/52,G-AJ=-128/56,F-AK=-126/53,E-AL=-138/61,
D-AM=-86/35,C-AN=-230/123,M-AE=-206/88,N-AD=-203/80,O-AC=-174/52,Q-AB=-128/56,
R-AA=-126/53,S-Z=-138/61,T-Y=-86/35,U-X=-230/123
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 3-0-0.Exterior(2)3-0-0 to 16-0-0,Corner(3)
16-0-0 to 20-0-0,Exterior(2)24-0-0 to 37-0-0 zone;cantilever left and right exposed;end vertical left and right
exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see
Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category Il;Exp B;Partially Exp.;Ct=1.1
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
7)All plates are 2x4 MT20 unless otherwise indicated.
8)Gable requires continuous bottom chord bearing.
9)Gable studs spaced at 2-0-0 oc.
&tlnlueTusn I�aatkyn designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
i
I
017 I Truss russ TYPQjY y I.GJ HOMES 2514•A RF
2514A C1 CommatSupported Gableob Reference Loitlgnal�_ _�
BMC,EVERETT,WA 982053212 8.000 s Jul 15 2016 MTek Industries,Ina Mon May 08 15 14.35 2017 Page 2
ID migzTLlh7FItsSOCFVTnRO6ziaVJ-Rxj?Cu?z AVVgDWHAmZ?zpBYsDumGOOO?YSVP1zIV6o
NOTES-
11)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members.
12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 7 lb uplift atjoint V,20 lb uplift at joint AG,26 lb uplift at joint AH,24
lb uplift atjoint Al,24 lb uplift at joint AJ,24 lb uplift at joint AK,26 lb uplift at joint AL,16 lb uplift at joint AM,45 lb uplift at joint AN,18 lb uplift at joint AE,27 lb
uplift at joint AD,24 lb uplift at joint AC,24 lb uplift at joint AB,24 lb uplift at joint AA,26 lb uplift at joint Z,16 lb uplift at joint Y,45 lb uplift at joint X and 6 lb
uplift at joint B.
13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSVTPI 1.
JobITNSS Truss ype y LGa HOMES 2514-A RF
2514-A C2 Common 5 1
Job Ref imnce(oo ionQ
BMC.EVERKET WA 9920532 2 6,000 s Jul 15 2016 MiTek Industries,Inc. Mon Mey 08 15.14 36 2017 Page 1
ID:migzTLjh7H1sSQCFVTnR06zlaVJ-v7HNQEObTq-,NSM5UjU4EVOhWud4bTmYECI� zIVBn
!0� 7-1-3 13-9A 20 0.0 , 26.2-12 32-10-13 40-0-0 �{
7-1-3 6 S-0 I 8.2-12 B 2-12 6 6-0 7-13-�
Scale=1:72.8
5.00 12 4x6=
' E
5x8 5-� N 0 5x8
D F
2x4 2x4 i
C VV3 1M3 G
M P
B 1
A HI
dd o
4x5= L Q R K S T J 4x5=
3x4= 5x8= 3x4=
18-9-0 18-9-0
10-3-14 20-0-0 29-8-2 40-0-0
10314 9$2 10.3-14
Plate Offsets(X Y)-- ID:04-0 0-3-41 (F70-4-0 0.3,41 IKOA-0 0.3-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 25.0 Plate Grip DOL 1.15 TC 0.96 Vert(LL) -0.36 J-K >999 240 MT20 185/148
(Roof Snow=25.0) Lumber DOL 1.15 BC 0.73 Vert(CT) -0.63 J-K >756 180
TCDL 7.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.16 H n/a n/a
BBCLL 00 0.0 Code IRC2015/TPI2014 (Matrix) Weight:161 Ib FT=10%
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 HF No.2 WEBS 1 Row at midpt F-K,D-K
MiTek recommends that Stabilizers and required cross
bracing be installed during truss erection,in accordance
with Stabilizer Installation guide.
REACTIONS. (lb/size) H=1739/0-5-8 (min.0-1-14),B=1739/0-5-8 (min.0-1-14)
Max Horz B=-105(LC 13)
Max UpliftH=-93(LC 13),8=-93(LC 12)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-13=0/42,B-M=-3564/172,C-M=-3490/193,C-D=-3209/166,D-N=-2242/177,E-N=-2165/195,E-0=-2165/195,F-0=-2242/177,F-G=-3209/166,
G-P=-3490/193,H-P=-3564/172,H-1=0/42
BOT CHORD B-L=-206/3199,L-Q=-94/2587,Q-R=-94/2587,K-R=-94/2587,K-S=-49/2587,S-T=A9/2587,J-T=-49/2587,H-J=-104/3199
WEBS F-K=-931/155,E-K=-5/1260,F-J=0/580,G-J=-422/161,C-L=-422/161,D-K=-932/155,D-L=0/580
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.11;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 3-0-0,Interior(1)3-0-0 to 16-0-0,Exterior(2)
16-0-0 to 20-0-0,Interior(1)24-0-0 to 37-0-0 zone;cantilever left and right exposed;end vertical left and right
exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1
3)Unbalanced snow loads have been considered for this design.
4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf.
8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 93 lb uplift at joint H and 93 lb
uplift at joint B.
9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
job TMSS Truss a Q y LGl HOMES 2514-A RF
2514-A C3 Common 12 1
Job Reference[o�t[onall
8MC.EVER TT.WA 12 8.OW s Jul IS5 2018 MITek IndueGias,Inc.Mon May 08 15:14.37 2017 Pa 1
1 0 ID:migzTLjh7HisSQCFV rm 'inRO6zfaVJ-NKda1DD76E4WggHBbT2EEIg1Q1kl3hSsN WMM
1-t�U 7-1-3 , 13-9-4 20-0-0 26-2-12 32-10-13 39-7-6
0- 7-1.3 6-2-12 T 6-2-12 6-8-0 6-8-9
Scale=1:72.2
5.00 12 4x6=
E
5x8 M N 5x8
D F
2x4 2x4
cc C VV3 W3 G
O
L
A B 1 H o
�1 I�
0
4x5= K P Q J R S I 5x6=
3x4= 5x8= 3x4=
18-9-0 18-9-0
10-3.14 20-" 29_-8-2 39-7-6
10-3.14 9-8-2 9 B-2 9.11-4
Plate Offsets(X.Y)— [D:04-0.0-341,[F:0_-4-0,0-34j 1J:04-0,0-3-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft L/d PLATES GRIP
TCLL 25.0 Plate Grip DOL 1.15 TC 0.95 Vert(LL) -0.35 J-K >999 240 MT20 185/148
(Roof Snow=25.0) Lumber DOL 1.15 BC 0.73 Vert(CT) -0.62 J-K >765 180
BCLL BCDL 0.7.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.16 H n/a n/a
BCDL 100 R Code IRC2015/TP12014 (Matrix) Weight:160 Ib FT=10%
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 HF No.2 WEBS 1 Row at midpt F-J,D-J
WEDGE MiTek recommends that Stabilizers and required cross
Right:2x4 HF No.2 bracing be installed during truss erection,in accordance
with Stabilizer Installation guide.
REACTIONS. (lb/size) B=1731/0-5-8 (min.0-1-14),H=1650/Mechanical
Max Horz B=109(LC 16)
Max UpliftB=-93(LC 12),H=-73(LC 13)
FORCES. (lb)-Maximum Compression/Maximum Tension
TOP CHORD A-B=0/42,B-L=-3544/175,C-L=-3470/196,C-D=-3189/169,D-M=-2221/180,E-M=-2145/198,E-N=-2145/198,F-N=-2222/185,F-G=-3149/181,
G-0=-3377/210,H-0=-3464/199
BOT CHORD B-K=-211/3181,K-P=-99/2569,P-Q=-99/2569,J-Q=-99/2569,J-R=-69/2551,R-S=-69/2551,I-S=-69/2551,H-1=-137/3109
WEBS E-J=-7/1245,F-J=-909/156,F-1=0/544,G-1=-375/158,D-J=-926/155,D-K=0/581,C-K=-422/161
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Exterior(2)-1-0-0 to 2-11-9,Interior(1)2-11-9 to 16-0-7,Exterior(2)
16-0-7 to 20-0-0,Interior(1)23-11-9 to 35-7-1 zone;cantilever left and right exposed;end vertical left and right
exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category 11;Exp B;Partially Exp.;Ct=1.1
3)Unbalanced snow loads have been considered for this design.
4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
5)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf.
8)Refer to girder(s)for truss to truss connections.
9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 93 lb uplift at joint B and 73 lb
uplift at joint H.
10)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2
and referenced standard ANSI/TPI 1.
}
I
' 1 ob Truss I fUSB Type y y LGI HC1ME$2514-A RR
2514-A C4 GABLE 1 1
Job Reference'optional)
BMC.EVERETT,WA 98205-3212 8.000 a Jul 15 2016 MYTek Industries,Ire Mon MeY 0815.14.38 2017
W-0Pa 1
ID:migzTLjh7H1sSQCFVTnR06ziaVJ-rM8rw2r RE5hgFsrv7ibRm36QwTTn7rhWJ9?MZIV8I
- 20-0-0 39-7-6 {
0- 20-0-0 19-7-6
Scale=1:73.2
5.00 12 4x5=
L M
3x4 K
I J N 3x4
H 0
G P p
F R
E S
p 8 7 T
6T1 5 1517 6 5 614
AN 3 3t2LV
3x4= AM AL AK AJ Al AH AG AF AE AD AC AB AA Z Y X W 3x4=
5x6=
18-9-0
39-7-6
39-7-6
Plate Offsets(KYf- rAE:0-3-0.0-3-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP
TCLL 25.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL) -0.00 A n/r 180 MT20 185/148
(Roof Snow=25.0) Lumber DOL 1.15 BC 0.07 Vert(CT) 0.00 A n/r 180
BCDL 7•0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.01 V n/a n/a
BCDL 10.0 Code IRC2015/TPI2014 (Matrix) Weight:196 lb FT=10%
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No.2 WEBS 1 Row at micipt L-AE
MiTek recommends that Stabilizers and required crass
bracing be installed during truss erection,in accordance
with Stabilizer Installation guide.
REACTIONS. (lb/size) V=129/39-7-6 (min.0-3-10),AE=160/39-7-6 (min.0-3-10),AF=168/39-7-6 (min.0-3-10),AG=168/39-7-6 (min.0.3-10),AH=168/39-7-6
(min.0-3-10),A1=169/39-7-6 (min.0-3-10),AJ=164/39-7-6 (min.0-3-10),AK=185/39-7-6 (min.0-3-10),AL=101/39-7-6 (min.0-3-10),
AM=326/39-7-6 (min.0-3-10),AD=168/39-7-6 (min.0.3-10),AC=166/39-7-6 (min.0-3-10),AB=168/39-7-6 (min.0-3-10),AA=169/39-7-6
(min.0-3-10),Z=164/39-7-6 (min.0-3-10),Y=182/39-7-6 (min.0-3-10),X=110/39-7-6 (min.0-3-10),W=309/39-7-6 (min.0-3-10),
B=216/39-7-6 (min.0-3-10)
Max HorzB=1o9(LC 12)
Max UpliftAF=-20(LC 12),AG=-26(LC 12),AH=-24(LC 12),AI=-24(LC 12),AJ=-24(LC 12),AK=-26(LC 12).AL=-16(LC 12),AM=-45(LC 12),
AD=-18(LC 13),AC=-27(LC 13),AB=-24(LC 13),AA=-24(LC 13),Z=-24(LC 13),Y=-26(LC 13),X=-15(LC 13),W=-50(LC 13),B=-4(LC 13)
Max GravV=129(LC 20),AE=167(LC 25),AF=243(LC 19),AG=240(LC 19),AH=202(LC 19),AI=169(LC 1),AJ=165(LC 19),AK=185(LC 1),
AL=101(LC 19),AM=326(LC 1),AD=246(LC 20).AC=243(LC 20),AB=214(LC 20),AA=169(LC 1),Z=165(LC 20),Y=182(LC 1),X=111(LC
20),W=309(LC 1),B=216(LC 1)
FORCES. (Ib)-Maximum Compression/Maximum Tension
TOP CHORD A-B=0/41,B-AN=-120/34,C-AN=-110/64,C-D=-88152,D-E=-66/61,E-F=-54176,F-G=-41/90,G-H=-39/103,
H-1=-29/106,I-J=-49/132,J-K=-59/169,K-L=-67/210,L-M=-67/210,M-N=-59/169,N-0=49/132,
O-P=-29/106,P-Q=-39/103,Q-R=-36/78,R-S=-36/51,S-T=-36/27,T-AO=-50/13,U-AO=-57/3,U-V=-90/42
BOT CHORD B-AM=-27/105,AL-AM=-27/105,AK-AL=-27/105,AJ-AK=-27/105,AI-AJ=-27/105,AH-AI=-27/105,
AG-AH=-27/105,AF-AG=-27/105,AE-AF=-27/105,AD-AE=-27/105,AC-AD=-27/105,AB-AC=-27/105,
AA-AB=-27/105,Z-AA=-27/105,Y-Z=-27/105,X-Y=-27/105,W-X=-27/105,V-W=-27/105
WEBS L-AE=-127/0,K-AF=-203/88,J-AG=-200/80,I-AH=-163/52,G-AI=-128/56,F-AJ=-126/53,E-AK=-138/61,
D-AL=-87/36,C-AM=-230/122,M-AD=-206/88,N-AC=-203/80,O-AB=-174/52,Q-AA=-128/56,R-Z=-127/53,
S-Y=-136/61,T-X=-94/37,U-W=-214/148
NOTES-
1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=25ft;Cat.II;Exp B;
enclosed;MWFRS(envelope)automatic zone and C-C Corner(3)-1-0-0 to 2-11-9,Exterior(2)2-11-9 to 16-0-0,Corner(3)
16-0-0 to 20-0-0,Exterior(2)24-0-0 to 35-7-13 zone;cantilever left and right exposed;end vertical left and right
exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see
Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
3)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 25.0 psf on
overhangs non-concurrent with other live loads.
6)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection
conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.
7)All plates are 2x4 MT20 unless otherwise indicated.
8)Gable requires continuous bottom chord bearing.
9)Gable studs spaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by
Con2ti0-0 yid p fit2between the bottom chord and any other members.
.�
1
O I I c FUSS uss y y LGI HOMES 2514A RF
2514A C4 GABLE 1 1
Job Reference(optional)
BPAC.EVERETT,WA 992053212 8.0W s Jul 15 20161ATau Industries.Inc,Mon May 0815:14:38 2017 Page 2
ID:migzTLjh7HlsSQCFVTnR06ziaVJ-rWP8rM2r REShgFsrv7ibRm36QwTTn7rhWJ9?MzIV81
NOTES-
12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 20 lb uplift at joint AF,26 lb uplift at joint AG,24 lb uplift at joint AH,
24 lb uplift at joint Al,24 lb uplift at joint AJ,26 lb uplift at joint AK,16 lb uplift at joint AL,45 lb uplift at joint AM,18 lb uplift at joint AD,27 lb uplift at joint AC,24
lb uplift at joint AB,24 lb uplift at joint AA,24 lb uplift at joint Z,26 lb uplift at joint Y,15 lb uplift at joint X,50 lb uplift at joint W and 4 lb uplift at joint B.
13)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
i
• i
6-00-00 20-06-00 19-06-00
N
4-00-00
00 91 Al
m
m
0
0
0
0
6-00-00 a
_ gg C2
H
Vl -
rt
3
r
d
c
'r
14-10-04 5-03-12 4-00-00 4-00-00 17-10.00 AD
8-00-00
r�
J'
y� Cpi17J� bz
z }
_`x 1
x N z p R%c ived
� z
OCT 7017
r�
Go Im
D.Day—I Deaignar 111 6 Ide1 'LGI HOMES ]ob Number Sheet Tille
u ,BMC BO35N Avaiue NEl Evmetl,N'A 981B1 ]ob Neme/Model 2514-FL DWgM! DAN C. TRUSS LAYOUT
OPow 125799S20B
AddHfe:
� i� Date 5/11/2017
iTe k
MiTek USA, Inc.
7777 Greenback Lane
Suite 109
Citrus Heights, CA, 95610
Telephone 916/676-1900
Re: 2514-FL Fax 916/676-1909
LGI HOMES 2514 FL
The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision
based on the parameters provided by BMC West-Everett, WA.
Pages or sheets covered by this seal: R50499425 thru R50499441
My license renewal date for the state of Washington is May 16,2019.
�E�LL 6
4AoF WAS��
,p 51398
May 8,2017
Baxter,David
IMPORTANT NOTE:Truss Engineer's responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
Job Truss [GABLE
ussType Qty Ply LGI HOMES 2514 FLR50499425
2514-FL Al 1 1
Job Reference o liorlal
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:38 2017 Page 1
I D:migzTLjh7 H 1 sSQCFV rnR06ziaVJ-tkuC2bgl HgDtMmx7KXJgpbm_l?aQx6H6?VgOLgzlYZB
0*8
Scale=1:30.9
A 8 C D E F G H I J K
yl-
b
W ax X X X X=X
V U T S R Q P O N M L
r 2�r 4-0-0 6.0-0 8 0-0 1 10-0-0 i 12-0-0 1 14 0 0 I 1&0-0 16-0-0 153 0
2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0
Plate Offsets(X,Y)-- [A:Edge.0-0.121.[W:0-1.8,0.0-121.[X:0-1-84-0-121
LOADING (psi] SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 400 Plate Grip DOL 1-00 TC 0.15 Vert(LL) n/a n/a 999 MT20 185/148
TCDL 100 Lumber DOL 1.00 BC 0.03 Vert(CT) n/a n/a 999
BCLL 0 0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 L n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:62 lb FT=Oe/F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals,
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No 2(flat)
REACTIONS. All bearings 19-3-0
(lb)- Max Grav All reactions 250 Ib or less at joint(s)V,L,U,T,S,R,Q,P,O,N,M
FORCES. (lb)-Max.Comp./Max Ten -All forces 250(lb)or less except when shown
NOTES-
1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors
2)All plates are 1 5x4 MT20 unless otherwise indicated
3)Gable requires continuous bottom chord bearing.
4)Truss to be fully sheathed from one face or securely braced against lateral movement(i a diagonal web)
5)Gable studs spaced at 2-0-0 oc.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails
Strongbacks to be attached to walls at their outer ends or restrained by other means.
7)CAUTION,Do not erect truss backwards
1,�RRII'L,
r0� k 51398 fQ,�
o� AcIs,rf~R� �v
�sSt�NAL���`
May 8,2017
,&WARNING-Verlry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE.
Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mire k'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suib:312,Alexandria,VA 22314. Suite 109
Citrus Hei his CA 95610
i
Job Truss Truss Type Qty Ply LGI HOMES 2514 FL
R50499426
2514-FL A2 Floor 9 1
Job Reference(optional)
BMC, EVERETT,WA 98205-3212 8,030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:39 2017 Page 1
ID:migzTLjh7H1 sSQCFV rnR06ziaVJ-LwSaFxrw2TLk_wVVKuFgvMolOgPhhgTdFD9axt6zlYZA
0-1-8
H, 2A" o^
Scale=1:31 6
4xB= 3x4= 3x4 = 4x8=
A B C D E F G H
0
6
P
N M L K
3x6 = 4x12 = 3x4 = 4x12 = 3x6 =
1930
IS."
Plate Offsets(X,Y)-- fA:Edge,0-0-121.IF:0-1-8.Edael.IM:0-1-8.Edgel.IP:0-1-8.0-0-121.FQ:0-1-8.0-0-121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/dell L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.73 Vert(LL) -0.33 M-N >686 480 MT20 185/148
TCDL 10,0 Lumber DOL 1.00 BC 0.99 Vert(CT) -0.49 M-N >470 360
BCLL 0.0 Rep Stress Incr YES WB '0.41 Horz(CT) 0.09 J n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:77 lb FT=O%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals.
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
REACTIONS. (lb/size) 0=1045/0-5-6,J=1045/0-2-10
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown
TOP CHORD B-C=-2894/0,C-D=-2894/0,D-E=-3563/0,E-F=-3563/0,F-G=-2881/0,G-H=-2881/0
BOT CHORD N-0=0/1719,M-N=0/3506,L-M=0/3563,K-L=0/3563,J-K=0/1714
WEBS B-0=-1951/0,B-N=0/1333,D-N=-695/0,D-M=-262/428,H-J=-1945/0,H-K=0/1325,G-K=-276/2,F-K=-912/0
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors
3)All plates are 1.5x4 MT20 unless otherwise indicated
4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means
6)CAUTION,Do not erect truss backwards.
- �gRRILC 8,q
J� Of WASN�,
W 0
51398 {q
0.l+ �QIS'TER�
NALE�G
May 8,2017
,&WARNING-Veniry design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 11,111-7473 rev,10/03/2015 BEFORE USE. ff
Design valid for use only with MiTek®conneclors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system_Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M iTe k.
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane
Salety Information available from Truss Plate Institute,218 N.Lee Street,Suihl 312,Alexandria,VA 22314. Suite 1o9
Citrus Heights. 1
i
Job Truss Truss Type Qty 7PlyLGI HOMES 2514 FLR50499427
2514-FL A3 Floor 3 Reference o Gonal
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May OB 13:21:40 2017 Page 1
ID:migzTLjh7H1 sSQCFV rnR06ziaVJ-p6OySHrYpnTbb35WSyL8uOrF1 p3VPxWOSpJVPYzIYZ9
0-1-8
H 2.6.0 IV"H1� 1-3-0 0i �
Scale=1:29.9
4x8= 3x4= 3x4 = 4x6= 3x4 I 4x8 II
A B C D E F G H I J
S o
o
R
P O N M L K
3x6 = 4x8 = 3x4= 4x8= 5x8=
17 4
17.8-12 a-e
Plate Offsets(X,Y)-- [kEdoe.0.0-121,IF:0-1.8.Edne1,IJ:0.3.O.Edge],I0:0.1-B,Edoe],IR:0-1.8.G-0-121.1S:0-1-8,0-a121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/dell Lid PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.51 Vert(LL) -0.24 O-P >883 360 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.88 Vert(CT) -0.35 0-P >597 240
BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(CT) 0.01 J n/a n/a
BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:76 lb FT=O%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No 2(flat) except end verticals
WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) J=952/0-1-8,Q=952/0-5-6
FORCES. (lb)-Max.Comp./Max,Ten,-All forces 250(Ib)or less except when shown.
TOP CHORD B-C=-2549/0,C-D=-2549/0,D-E=-2884/0,E-F=-2884/0,F-G=-2515/0,G-H=-2515/0,H-1=-811/0,I-J=-814/0
BOT CHORD P-Q=0/1546,O-P=0/2988,N-0=0/2884,M-N=0/2884,L-M=0/1541
WEBS J-L=0/1176,B-Q=-1755/0,B-P=0/1137,D-P=-498/0,D-0=-340/240,H-L=-1057/0,H-M=0/1106,F-M=-660/0
NOTES-
1)Unbalanced floor live loads have been considered for this design,
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3)All plates are 1 5x4 MT20 unless otherwise indicated.
4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J.
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
6)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
7)CAUTION,Do not erect truss backwards.
tJ,ERYJLL 6
WAsy/ �f j
ADO RE51398� �cy�
_ .� c�s•r�R �
�SS7�NAL��G`
May 8,2017
A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.1010312015 BEFORE USE.
Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design Bracing indicated is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing M iTe k
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N,Lee Street,Suito 312,Alexandria,VA 22314. Suite 109
r:Arus Hegnis C/„45010
i
Job Truss Truss Type Qty Ply 1 LGI HOMES 2514 FL
R50499428
2514-FL A4 Floor 2 1
Job Reference(optional)
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:41 2017 Page 1
I D:migzTLjh7H 1 sSQCFVTnR06zlaVJ-HJaKgdsAa4bSDDgi?gsNRDOQnDPk8OmYhT32y?zlYZB
0-1-6
H 2.e.0 i I 1-3-0 1-3-0 3-01
Scale=1:29.9
4x8= 3x4= 3x4 = 4x6= 3x4 I 4x8 I
A B C D E F G H I J
S o
R
P O N M L K
3x6 = 4x8= 3x4= 48= 5x8=
17.6-12 17r09V
17-6-12 3 0
Plate Offsets(X Y)— (A:Edne 0.0.121 tF:0-1.8 Edgel (J:0-3-0 Edgel (0:0-1-8 Edgel (R:0-1-8.0A-121.fS:0-1-8,0.0.121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.51 Vert(LL) -0.24 O-P >883 360 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.88 Vert(CT) -0.35 O-P >597 240
BCLL 0 0 Rep Stress Incr YES WB 0.36 Horz(CT) 0.01 J n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:76 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) J=952/0-2-14,Q=952/0-5-6
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD B-C=-2549/0,C-D=-2549/0,D-E=-2884/0,E-F=-2884/0,F-G=-2515/0,G-H=-2515/0,H-1=-811/0,I-J=-814/0
BOT CHORD P-Q=0/1546,O-P=0/2988,N-0=0/2884,M-N=0/2884,L-M=0/1541
WEBS J-L=0/1176,B-Q=-1755/0,B-P=0/1137,D-P=-498/0,D-0=-340/240,H-L=-1057/0,H-M=0/1106,F-M=-660/0
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions It is
the responsibility of the fabricator to increase plate sizes to account for these factors
3)All plates are 1 5x4 MT20 unless otherwise indicated
4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)J
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
6)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
7)CAUTION,Do not erect truss backwards.
�$RRIL� 6
wns ,"�!�,
o
51398 .4�
crSTE
�sstoNALENG
May 8,2017
,&WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev.10/03/2015 BEFORE USE.
Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not
a buss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see AN8IITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N-Lee Street,Suit.312.Alexandpi,VA 22314. Suite 109
»rus Heights, 95610
Job Truss Truss Type City Ply LGI HOMES 2514 FL
R50499429
2514-FL A5 FLOOR 3 1
Job Reference o fional
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:42 2017 Page 1
ID:migzTLjh7H1 sSQCFVTnRO6zlaVJ-mV8jtztpLOjJrNFvZNNc_Rwaldjitgzhv7ocURzIYZ7
0-1-8
• Hr 1-3-0 08
Scale=1:29.0
4x8 = 3x4 = 3x4 = 4x6 =
A B C D E F G H I
Q
0
uS
Ple L
N M L K
3x6= 4x8= 3x4 = 4x6= 3x6 =
17.9.12
17-9-12
Plate Offsets(X,Y)-- [A:Edge,0-0-121,[F:0-1-8,Edael,[M:0-1-8,Edgel.[P:0-1-8,0-0-121.[0:0-1-8,0-0-121.[R:0-1-8,0-0-121.fS:0-1-8,0-0-121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP
TCLL 400 Plate Grip DOL 1.00 TC 056 Vert(LL) -0.25 M-N >826 480 MT20 185/148
TCDL 100 Lumber DOL 1.00 BC 090 Vert(CT) -0.37 M-N >558 360
BCLL 0 0 Rep Stress Incr YES WB 037 Horz(CT) 0.07 J n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:73 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals.
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 0=959/0-5-6,J=959/0-3-6
FORCES. (lb)-Max Comp/Max Ten -All forces 250(lb)or less except when shown.
TOP CHORD B-C=-2574/0,C-D=-2574/0,D-E=-2926/0,E-F=-2926/0,F-G=-2547/0,G-H=-2547/0
BOT CHORD N-0=0/1560,M-N=0/3026,L-M=0/2926,K-L=0/2926,J-K=0/1558
WEBS B-0=-1770/0,B-N=0/1152,D-N=-513/0,D-M=-340/251,H-J=-1768/0,H-K=0/1122,F-K=-672/0
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions It is
the responsibility of the fabricator to increase plate sizes to account for these factors
3)All plates are 1.5x4 MT20 unless otherwise indicated
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
thE�'L 6
WASft� `tJ
0 R�51398 ¢�
.' CISTE
�ss70NAL��G
May 8,2017
,&WARNING.Verify design paramefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe I<
is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suibt 312,Alexandria,VA 22314. Suite 109
Citrus Heights.CA 9561Q
Job Truss Truss Type Qty Ply LGI HOMES 2514 FL
R50499430
2514-FL A6 GABLE 1 1
Job Reference lionat
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:43 2017 Page 1
I D:migzTLjh7H 1 sSQCFVTnRO6zlaVJ-Ehi55JuR6irASXg575urWeTgsOHicM Wf8nY90tzlYZ6
O-kB 0-k8
Scale=1:28 6
A B C D E F G H I J
V ] X
U W
T S R Q P O N M L K
2 0-0 4-0
2 0-0 2,020 2 0 0 6-0-0 } B•0 0 1 10.0-0 12-0-0 1 14.0.0 I tt3-0-0 d IZ�12 r
2-0.0 2-0.0 2-0-0 2-0-0 2.0-0 1-912
Plate Offsets(X Y)-- [A•Edoe 0-0-121 IU.0-1-8 0-0.121 N:0-1.8 0-0.121 [W:0-1-8 0.0-121.[X:0-1-8,0-0-121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 400 Plate Grip DOL 1 00 TC 015 Vert(LL) n/a n/a 999 MT20 185/148
TCDL 100 Lumber DOL 1.00 BC 002 Vert(CT) n/a n/a 999
BCLL 0.0 Rep Stress Incr YES WB 003 Horz(CT) 0.00 K n/a n/a
BCDL 5.0 Code IRC2015/71312014 Matrix-R Weight:58 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No 2(flat) except end verticals
WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No 2(flat)
REACTIONS. All bearings 17-9-12
(lb)- Max Grav All reactions 250 Ib or less at joint(s)T,K,S,R,Q,P.0,N,M,L
FORCES. (lb)-Max.Comp./Max.Ten--All forces 250(lb)or less except when shown
NOTES-
1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors
2)All plates are 1 5x4 MT20 unless otherwise indicated
3)Gable requires continuous bottom chord bearing.
4)Truss to be fully sheathed from one face or securely braced against lateral movement(Le diagonal web)
5)Gable studs spaced at 2-0-0 oc
6)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails
Strongbacks to be attached to walls at their outer ends or restrained by other means
ORRILL
�� oQ wnskw'�f�,
ti� coo�
51398k+�
Off, �QISTER�
AL��G
May 8,2017
A WARNING-verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111I1.7473 rev.10/03/2015 BEFORE USE.
Design valid for use onty with MiTeW connectors.This design is based only upon parameters shown,and Is for an individual budding component,not
I
truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated 4 to prevent buckling of individual truss web andlor chord members only. Addaionel temporary and permanent bracing MiTek'
I
s always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the
fabrication,storage,delivery,erection and bracing oftrusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 K Lee Street,Suite 312,Alexandria,VA 22314. Suite 109
Citrus Heights.CA 95610
i
Job Truss Truss Type Qty ply LGI HOMES 2514 FL
R50499431
2514-FL B1 GABLE 1 1
Job Reference o tional
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:44 2017 Page 1
I D:migzTLjh7H 1 sSQCF V rnR06ziaVJ-iuGTifu3t?zl4hPHhoQ43sO?VQdnLpm_N RHiYJzIYZ5
0-P
Scale=1:33.2
3x6 FP=
A B C D E F G H I J K L M
d4B
AA
tRX30TZ-2 kXXXX�7'7�51,2 JXXXX77LJ J J t7777_1�
Z Y x W V U T S R Q P 0 N
3x6 FP=
1 8 1 S 12 10 8.1 1 1 14 8- 1 18.8.1 8.8
08 12 2 4-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0 0 2-0-0 2.0-0 2-0-0 1.11.12
9:0Plate Offsets(X,Y)-- fA:goe.0.0.121.(AA:D-1-8,0-0-12L fAB:0-1-8.0-0-121
LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 016 Vert(LL) n/a n/a 999 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 003 Vert(CT) n/a n/a 999
BCLL 0.0 Rep Stress Incr YES WB 003 Horz(CT) 0.00 N n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:67 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals.
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No.2(flat)
REACTIONS. All bearings 20-7-0.
(lb)- Max Grav All reactions 250 Ib or less at joint(s)Z,N,Y,X,V,U,T,S,R,Q,P,O
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown
NOTES-
1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
2)All plates are 1.5x4 MT20 unless otherwise indicated.
3)Gable requires continuous bottom chord bearing
4)Truss to be fully sheathed from one face or securely braced against lateral movement(i e.diagonal web).
5)Gable studs spaced at 2-0-0 oc.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails
Strongbacks to be attached to walls at their outer ends or restrained by other means.
7)CAUTION,Do not erect truss backwards,
-RMLL ,0 '
WASH
51398 1g,�
�ss�ONALE��
May 8,2017
,&WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1i rev.10/03/2015 BEFORE USE. '
_ Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nil
building design Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M iTe k'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N-Lee Street,Suite 312,Alexandria,VA 22314. Suite 109
Cjtn4He' 10
_ i
Job Truss Truss Type Qty Ply LGI HOMES 2514 FL
R50499432
2514-FL B2 Floor 5 1
Job Refe ence o Gonal
BMC, EVERETT,WA 98205-3212 8,030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:45 2017 Page 1
1 D:migzTLjh7H 1 sSQCFVTnRO6zlaVJ-A4prW?vheJ5uir_TEVxJb3Y4SgoB4AZ8c51 G5mzIYZ4
1 2.6.0 1-3-0 1-1-0 0*8
Scale=1:33.6
4x8= 3x6= 3x4= 3x6 FP= 4x8 =
A B C D E F G H I J K
T7 '�\- 0
i-
s
::!E :4 — 7s:i
3x10 = Q P O N M
3x6 FP= 3x4= 3x4= 4x12 = 3x6=
4x12=
20--"
r 20-8-8 i
Plate Offsets(X.Y?-- IAEdne.0-0.121,IN:0-1-8.Edael.110:0.1-8.Edae1,tS:0-1-8.0-0.121,tT:0-1-8.0.0.121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP
TCLL 40.0 Plate Grip DOL 1 00 TC 0.53 Vert(LL) -0.35 M-N >700 480 MT20 185/148
TCDL 100 Lumber DOL 1.00 BC 0.72 Vert(CT) -0 50 M-N >492 360
BCLL 0.0 Rep Stress Incr YES WB 0.44 Horz(CT) 009 L n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:89 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat)"Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
A-I:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat) except end verticals
BOT CHORD 2x4 HF No.2(flat)"Except" BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing
L-Q:2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat)
WEBS 2x4 HF No.2(flat)
REACTIONS. (lb/size) L=1125/0-5-6,R=1125/0-2-10
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD B-C=-3190/0,C-D=-3190/0,D-E=-4170/0,E-F=-4170/0,F-G=-4170/0,G-H=-3192/0,
H-J=-3192/0
BOT CHORD P-R=0/1861,O-P=0/3946,N-0=0/4170,M-N=0/3952,L-M=0/1868
WEBS J-L=-2120/0,B-R=-2112/0,J-M=0/1502,B-P=0/1508,C-P=-261/0,G-M=-863/0,
D-P=-857/0,G-N=-158/586,D-0=-108/612,E-0=-326/38
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3)All plates are 1.5x4 MT20 unless otherwise indicated.
4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)R
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
6)CAUTION,Do not erect truss backwards
41
,� OF WASN,,
'W t�
�0� 51398 w'�
OAS, FQ/STER�
`4S�ONALE�G
May 8,2017
WARNING.Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.1010312015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design Bracing Indicated is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPI1 quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Salety Information available from Truss Plate Institute,218 N Lee Street,Suite 312,Alexandria,VA 22314 Suite 109
Citrus Hel.hts,CA 95610
. i
Job Truss Truss Type Qty IPly 1 LGI HOMES 2514 FL
R50499433
2514-FL B3 Floor 5 1
Job Reference (optional)
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:46 2017 Page 1
I D:migzTLjh7H 1 sSQCFV rnR06ziaVJ-eGNDjKwJPdDIJ_YgoDSY8H5EPE8ypcgHglmpdCzIYZ3
r24L-0� �i 1i 1� 1-8-14-kB
Scale=1:37.5
4x8= 3x6 FP= 3x4= 3x6 = 4x12 = 3x4 11 3x4 =
A B C D E F G H 1 J K L
V o
U
T S R Q P 0 N M
3x6 = 4x12 = 3x4= 3x4= 3x6 FP= 4x12 =
4x12 =
1
20.7-2 0- 8 1-11-14
Plate Offsets(X.Y)-- A:Edge 0-0-121 IL:0-1-8,Edge1 IQ:0-1-8.Edge1,IR:0-1-8 Edgel,FU:0-1-8.0-0-121,IV:0-1-8.0-01121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.58 Vert(LL) -0.36 P-Q >688 480 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.75 Vert(CT) -0.48 P-Q >513 360
BCLL 0.0 Rep Stress Incr NO WB 0.45 Horz(CT) 0.08 N n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:99 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1&Btr(flat)"Except" TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
A-D:2x4 HF No.2(flat) except end verticals.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr(flat)"Except" BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing,
M-0:2x4 HF No.2(flat)
WEBS 2x4 HF No.2(flat)
REACTIONS. (lb/size) T=1087/0-2-10,N=1711/0-5-8
Max Grav T=1104(LC 3),N=1711(LC 1)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD B-C=-310810,C-E=-3108/0,E-F=-4021/0,F-G=-4021/0,G-H=-402110,H-1=-2949/0,
I-J=-2949/0,J-K=0/555,K-L=0/552
BOTCHORD S-T=0/1823,R-S=0/3828,Q-R=0/4021,P-Q=0/3751,N-P=0/1582
WEBS K-N=-265/0,B-T=-2069/0,B-S=0/1459,C-S=-256/0,J-N=-2165/0,J-P=0/1591,
H-P=-944/0,H-Q=-98/668,E-S=-817/0,E-R=-171/569,F-R=-302/71,L-N=-677/0
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions It is
the responsibility of the fabricator to increase plate sizes to account for these factors
3)All plates are 1.5x4 MT20 unless otherwise indicated.
4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)T
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Old(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
6)CAUTION,Do not erect truss backwards. c1
LOAD CASE($) Standard ,`r OF AS
1)Dead+Floor Live(balanced):Lumber Increase=l 00,Plate Increase=l 00
Uniform Loads(plf)
Vert:M-T=-10,A-L=-100
Concentrated Loads(lb)
Vert:L=-328
Ada 51398� wq�
41 L?ISTE�
�SSJONAL B�G�
May 8,2017
WARNING•Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Ml1.7473 rev.10/03/2015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
.
a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MTek'
is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSO.89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109
Citrus Heiahts.CA 9 610
_ i
Job Truss Truss Type Qly Ply LGI HOMES 2514 FL
R50499434
2514-FL C1 Floor 3 1
Job Reference o tional
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:47 2017 Page 1
I D:migzTLjh7 H 1 sSQCFVTnR06zl aVJ-6SxcwgxxAwLcx87 sMwznhUdUteYpY7UQ3P WN9ezIYZ2
0-1-B
1-1-8 Hil 2-9.0 0-Q-4 01118i _i
Scale=1:23.3
• 1.5x4 I
4x6 3x4 I 3x4= 1.5x4 3x4= 3x4 I 4x6 II
A 8 C DE F G H
0 0
u5 9
N M L K3x4 J I
1.5x4 I 4x6= 3x4= 4x6= 1 5x4 II
0 1 3 1.12 4
0• 13.0.4 _ 0-
Plate Offsets(X,Y)— �A:0-3-O,Edge] K0-3-0,Edge],L:0-1-8 Edge],[L•0-1-$,Edge]
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/dell Ltd PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.28 Vert(LL) -0,07 L >999 480 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.46 Vert(CT) -0.11 L-M >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(CT) -0.02 H n/a n/a
BCDL 5.0 Code IRC2015/TP12014 Matrix-R Weight:59 lb FT=O%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing
REACTIONS. (lb/size) A=709/0-1-8,H=709/0-1-8
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD A-B=-632/0,B-C=-631/0,C-D=-1709/0,D-E=-1709/0,E-F=-1709/0,F-G=-631/0,G-H=-632/0
BOT CHORD L-M=0/1413,K-L=0/1709,J-K=0/1413
WEBS A-M=0/915,H-J=0/915,F-J=-887/0,C-M=-887/0,F-K=0/416,C-L=0/416
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A,H.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
ORRI l- 8
wns '�F�,
Vd4► �, 51398 �
0., �orSTF
�sS'IONAL ENO
May 8,2017
• AWARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Ml1.7477 rev.10/e3/2015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall W11,
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITP11 Quality Criteria,DSB-Bg and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N Lee Street,Suit:312,Alexandra,VA 22314. Suite 109
Job Truss Truss Type Oty Ply LGI HOMES 2514 FL
R50499435
2514-FL C2 Floor 1 1
Job Reference o tlonal
BMC, EVERETT,WA 98205-3212 8,030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:47 2017 Page 1
ID:migzTLjh7H1 sSQCFVTnR06ziaVJ-6Sxcwg>o AwLcx87sMwznhUdTReaZY8lQ3PWN9ezlYZ2
0-3-0
t-1 8 r r r 2.6 0 ; r 1�� 0
tale=1:155
_ 3x6 3x4 I 3x4= 1.5x4 II
A B C D 3x4 = E
L
1.5x4=
0
1.5x4 =
K
3x6 =
J I H G F
1 5x4 1 5x4 11 1 5x4 I
3x4 =
4
3-0 7-11-14
Plate OHsels(X,Y)-- fC:0.1-8,Edgel,fD:0.1-8,Ed9eL IJ:Edge,0-0-121.IK:O-1.8,0.0.121.IL:0-t-8,0.0.121
LOADING (psf) SPACING- 2-0-0 CST. DEFL. in (loc) I/defl Lid PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL) -0.05 H-1 >999 480 MT20 185/148
TCDL 10.0 Lumber DOL 1 00 BC 0.35 Vert(CT) -0.06 H-1 >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(CT) -0.01 F n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:37 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) A=426/0-2-14,F=426/0-3-8
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD A-B=-383/0,B-C=-383/0,C-D=-601/0
BOT CHORD H-1=0/601,G-H=0/601,F-G=0/601
WEBS B-1=-269/0,A-1=0/555,D-F=-678/0,C-1=-281/0
NOTES-
1)Unbalanced floor live loads have been considered for this design.
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in
6)CAUTION,Do not erect truss backwards.
- �RR1l.0 6
a� Of
Ec�s51398 <y�
�.� rsR� k/
`c'sSrONALB���
May 8,2017
WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7477 rev.10/07/2015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mirek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of Trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suilo 312,Alexandria,VA 22314. Suite 109
Citrus ejobts.CA 9561
Job �Tfusa Truss Type Qty Ply LGI HOMES 151111
iR50499436
2514-FL D11 Floor 3 1
Job Reference(optional)
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:48 2017 Page 1
I D:migzTLjh7H 1 sSQCFVTnRO6zi aVJ-afV_BOyZwETSZI i2weUODiAep 1 wnHbya 13Fwh5zlYZ1
0-1-8
1-1-8 2414 F , 1-5-12 , 1-3-0
SWfe=1:25.5
1.5x4
1.5x4=
3x6 II 3x4 11 3x4 = 3x4 II 3x4= 1 5x4 11 3x4 = 1.5x4=
A B C D Q E F G H
P
0
N M K J3x4 = t
1-5x4 I 3x6 = 3x6= 1.5x4 3x4 =
0• . 4 -
12
0• 6.7.10 8.2-10
Plate Offsets(X,Y)•- IE:0-1-8.Edue1.IJ:0-1-B,Ed0el,10:0-1.8.134121.(P:0-1-6.04121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.33 Vert(LL) -0.05 I-J >999 480 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.28 Vert(CT) -0.08 I-J >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(CT) 0.01 1 n/a n/a
BCDL 5.0 Code IRC2015rrPI2014 Matrix-R Weight:64 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals.
WEBS 2x4 HF No.2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) A=346/0-1-8,L=818/0-5-8,1=443/0-3-7
Max Grav A=395(LC 8),L=818(LC 1),1=446(LC 8)
FORCES. (lb)-Max.Comp,/Max.Ten -All forces 250(lb)or less except when shown.
TOP CHORD A-B=-346/0,B-C=-344/0,E-F=-637/0,F-G=-637/0
BOT CHORD L-M=0/550,K-L=0/637,J-K=0/637,I-J=0/603
WEBS A-M=0/499,D-L=-274/0,C-L=-517/0,G-1=-684/0,E-L=-689/0
NOTES-
1)Unbalanced floor live loads have been considered for this design
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)A.
4)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means
5)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
6)CAUTION,Do not erect truss backwards.
_ �gtLRIL(, 6
J� OF WASIt� -lT
51398 ww4
sS�oNAU���,
May 8,2017
AWARNING•Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7477 rev.10/07/2015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system.Before use,the building designer must verity the applicability of design parameters and property incorporate this design into the overall Nil'
building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPIt Quality Criteria.DSB-89 and Boat Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suitt)312,Alexandria,VA 22314. Suite 109
Carus Hei s CA 95610
Job Truss Truss Type Qty Ply LGI HOMES 2514 FL
R50499437
2514-FL D3 Floor 5 1
ob Reference tlonal
BMC, EVERETT.WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc, Man May 08 13:21:50 2017 Page 1
ID:migzTLjh7H1 sSQCFV rnR06ziaVJ-Xl dkZizgSrjAocsR13WU17FuNrR5ITstINk1 mzzlYZ?
0-1-8
2�1�---�F J 4 I � 1 � °- B
HI Scale :33.4
3x4= 3x4= 3x4 4x6 = 3x4 = 3x6 FP= 3x6=
A B C D E F G H I J K
X o
U
S R Q O N M
3x4 = 3x6 FP= 3x10= 3x6= 3x10= 3x6 =
5.5.8 20-5.4
5-5.8 14.11.14
Plate Oftsets(X.Y)-- IA:Edge,0-0-121.fB:0-1-8.Edae] fC:0-1-8.Edge].IG:0-1-8 Edge].f0:0-1-S.Edoe].Iu:0-1-8.0.0.121.rv:0-1-8.0-0-121,IW 0-1-8.0.0-121.(x:0-1-8.0.0-121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.71 Vert(LL) -0.25 M-N >716 480 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 1.00 Vert(CT) -0.32 M-N >561 360
BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(CT) 0.04 L n/a n/a
BCDL 5.0 Code IRC2015ITP12014 Matrix-R Weight:84 lb FT=0%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No.2(flat) except end verticals,
WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
REACTIONS. (lb/size) L=801/0-5-6,T=258/0-3-6,P=1148/0-3-8
Max Grav L=805(LC 7).T=333(LC 10),P=1148(LC 1)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD B-C=-380/62,E-F=-2057/0,F-G=-2057/0,G-H=-2024/0,H-J=-2024/0
BOT CHORD S-T=-62/380,R-S=-62/380,P-R=-62/380,O-13=011228,N-0=0/2057,M-N=0/2057,
L-M=0/1269
WEBS B-T=-429/70,C-13=492/0,E-P=-1483/0,E-0=0/992,F-0=-337/0,J-L=-1440/0,
J-M=0/857,H-M=-320/0,G-M=-294/128
NOTES-
1)Unbalanced floor live loads have been considered for this design
2)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions- It is
the responsibility of the fabricator to increase plate sizes to account for these factors
3)All plates are 1.5x4 MT20 unless otherwise indicated
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5)CAUTION,Do not erect truss backwards.
J� of wAsr ,"�P�
no 51398�0 w�
SSr�NAL��G
May 8,2017
AWARNING.verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE MII.7473 rev.1010312015 BEFORE USE.
Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not
a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-99 and SCSI Building Component 7777 Greenback Lane
Safely Information available from Truss Plate Institute,218 N.Lee Street,Suito 312,Alexandria,VA 22314. Suite 109
Citrus Hei his CA 95610
Job Truss Truss Type 'Qty Ply LGI HOMES 2514 FL
R50499438
2514-FL D4 GABLE 1 1
Job Reference o bona
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:51 2017 Page 1
ID:migzTLjh7H1 sSQCFVTnRO6zlaVJ-?EB6m2_SD9rl QmRdbm2jrKoCeFOGU_UO_l UalPzIYZ_
0*8 0*8
Scale=1:33.6
3x6 FP= 2x4 I
A B C D E F G H I J K L M
AC_
Z AB
Y X W V U T S R O P O N
3x6 = 3x6 FP=
0-5-8
0- 2.5.8 MS8 8.5• 41 1 1 -5.8 14-b41 t&5.8 1&5•S 2aS•4
0-43 2•a0 2-11 2.O-0 2-0-0 2-0.0 2-D•0 2•a0 2•a0 2A•0 1.11.12
0-4-0
Piste Offsets(X,Y)-- IA:Edge,0.0.121,[M:0-1-8,Edge],IZO.1.8.0•0-121,fAA:0.1-8.0-0.121,fA$:0-1-8.0.0-121.[AC:0.1.8.0.0.121
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP
TCLL 40-0 Plate Grip DOL 1.00 TC 0.16 Vert(LL) n/a n/a 999 MT20 185/148
TCDL 100 Lumber DOL 1 00 SC 0.04 Vert(CT) n/a n/a 999
BCLL 0-0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 N n/a n/a
BCDL 5.0 Code IRC2015(T1312014 Matrix-R Weight:67 lb FT=O%F,12%E
LUMBER- BRACING-
TOP CHORD 2x4 HF No 2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 HF No 2(flat) except end verticals
WEBS 2x4 HF No 2(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 HF No 2(flat)
REACTIONS. All bearings 20-2-4
(lb)- Max Grav All reactions 250 Ib or less at joint(s)Y,N,X,V,U,T,S,R,Q,P,O
FORCES. jib)-Max Comp/Max Ten -All forces 250(lb)or less except when shown.
NOTES-
1)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
2)All plates are 1 5x4 MT20 unless otherwise indicated
3)Gable requires continuous bottom chord bearing
4)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e-diagonal web)
5)Gable studs spaced at 2-0-0 oc
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails
Strongbacks to be attached to walls at their outer ends or restrained by other means
�1�RRILL 6
J19 WASF "T>
Q' A
�O� k 51398 w�
SS��NALB�G
May 8,2017
AWARNING-verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. '
Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is loran individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall 191
building design Bracing indicated is to prevent buckling of individual truss web andlor chord members only.Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
rabricalion,storage,delivery,erection and bracing of Trusses and truss systems,see ANSIITPI7 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,21e N.Lee Street,SuNr 312,Alexandria,VA 22314. Suite 109
Citrug Heights,CA 9 610
Job Truss Truss Type Qty Ply LGI HOMES 2514 FL
R50499439
2514-FL F1 FLOOR GIRDER 1
Job Reference(optional)
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:51 2017 Page 1
I D:migzTLjh7 H 1 sSQCF VTnRO6zlaVJ-?EB6m2_SD9rl QmRdbm2jrKo8PFyh UxRO_1 Ual PZIYZ_
r T-11-3
Scale:V=1'
A 45 I F B 3x4= C4x5 II
u5
3x4= 3x4 =
r 61-14 1
6-1-14 0-3-8
Plate Offsets(X,Y}-- [C:Ed11e,Q-3-81
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.43 Vert(LL) 000 D-E >999 480 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.27 Vert(CT) -0 00 D-E >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.22 Horz(CT) 0,01 D n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-R Weight:53 lb FT=12%
LUMBER- BRACING-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 DF 1 GOOF 1.6E or 2x4 DF No.1&Btr except end verticals.
WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing
REACTIONS. (lb/size) E=1529/0-5-8,D=1855/0-11-14
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD A-E=-450/0,C-D=-783/0,A-B=-284/0,B-C=-304/0
BOT CHORD D-E=0/2979
WEBS B-E=-2891/0,B-D=-2870/0
NOTES-
1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-9-0 oc.
Bottom chords connected as follows:2x4-1 row at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section Ply to
ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard
1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plf) RRILL8
WAS
Vert:D-E=-10,A-F=-100,C-F=-527 ,19 F x �
Concentrated Loads(lb)
Vert:F=-1034 hQ� 0
vOvQ ,� 51398
S%NAL��G
May 8,2017
AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.10/03/2015 BEFORE USE.
Design valid for use only with MiTek®connectors,This design is based only upon parameters shown,and is for an individual building component,not
a buss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mire k'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-69 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,AlexaWa.VA 22314. Suite 109
Citrus Heicibts.CA 95610
Job Truss Truss Type City Ply LGI HOMES 2514 FL
R50499440
2514-FL F2 FLOOR GIRDER 1
Job Reference o tional
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:52 2017 Page 1
ID:migzTLjh7H1sSQCFVTnRO6zlaVJ-TQkU_0?4_TzulvOg9UZyNYLNKfEVDL49DhD7pszlYYz
r 2.6.4
Scale=1:11.1
5x6
A 5x6= B1 5x4 II C
LJ
6x12 =
G E H I
1-5x4 11 1-5x4 11
12
1 1 n 5-7-8 6-i t-0
0.3.8 B 0 2.8-0 0.3 8
LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/dell Ud PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0.04 E-F >999 480 MT20 185/148
TCDL 10.0 Lumber DOL 100 BC 0.55 Vert(CT) -0 05 E-F >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.39 Horz(CT) -0 00 D n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-P Weight:49 lb FT=12
LUMBER- BRACING-
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 5-11-0 oc purling,
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr except end verticals.
WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) F=1648/0-5-8,D=2232/0-5-8
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD A-F=-1199/0,C-D=-1199/0,A-B=-3065/0,B-C=-3065/0
WEBS A-E=0/3235,C-E=0/3235
NOTES-
1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-9-0 oc.
Bottom chords connected as follows:2x4-1 row at 0-9-0 oc_
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to
ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard
1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plo
Vert:D-F=-10,A-C=-100 gRRILL
Concentrated Loads(lb) �►
Vert:G=-1085 H=-1085 1=-1092 J`0� F WASk
Q O
vO�O 51398� w�
.1 c/S'rER
�SS10 AL
May 8,2017
AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev.1010312015 BEFORE USE. �-
Design valid for use only with MiTek®connectors This design is based only upon parameters shown,and is for an individual building component,not
a truss system Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design Bracing indicated is to prevent buckling of individual truss web and/or chord members only Addkional temporary and permanent bracing Welk'
always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safety Information available from Truss Plate Institute,218 N.Lee Street,Suilm 312,Alexandria,VA 22314. Suite log
citrus Hih A 95610
Job Truss Truss Type pry Ply LGI HOMES 2514 FL
R50499441
2514-FL F3 FLOOR GIRDER 1 2 Job Reference oral
BMC, EVERETT,WA 98205-3212 8.030 s Jan 23 2017 MiTek Industries,Inc. Mon May 08 13:21:53 2017 Page 1
I D:migzTLjh7H 1 sSQCF VTnR06zlaVJ-xcltBk?ilm5lf3bOiB4BwltN32XPymvJ RLzh Mlzlyyy
i 2-0-0 0
Scale=1:18 0
1.5x4 II 4xl2 = 1.5x4 II 1.5x4 II 4xl2 = 1.5x4 II
A K B L C D M E F
u
N
I H 3x10 =
3x10 =
4x8 = 4x8 =
4 3 8 58 a 9-10_0
4-3-6 1-3-0 4-3-8
Plate Offsets(X.Y)— (KID4 8,0-1.81.f1:0-3.8,0-1-81
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.87 Vert(LL) -0.13 H-1 >870 480 MT20 185/148
TCDL 10.0 Lumber DOL 1.00 BC 0.77 Vert(CT) -0.18 H-1 >625 360
BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(CT) 0.03 G n/a n/a
BCDL 5.0 Code IRC2015/TPI2014 Matrix-RH Weight:92 lb FT=12%
LUMBER- BRACING-
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 2-11-6 oc purlins,
BOT CHORD 2x6 DF SS except end verticals.
WEBS 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing
REACTIONS. (lb/size) G=3789/0-4-8,J=3714/0-5-8
Max Grav G=3789(LC 1),J=3718(LC 3)
FORCES. (lb)-Max.Comp/Max.Ten.-All forces 250(Ib)or less except when shown
TOP CHORD A-J=-475/0,F-G=-990/0,B-C=-9514/0,C-D=-9514/0,D-E=-9514/0
BOT CHORD I-J=0/7419,H-1=0/9514,G-H=0/6325
WEBS E-G=-6819/0,B-J=-7998/0,E-H=0/3557,B-I=0/2264,C-1=-1075/0,D-H=-1510/0
NOTES-
1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-7-0 oc.
Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-7-0 oc,Except member WE 2x4-1 row at 0-9-0 oc,member I-B 2x4-1 row at 0-9-0 oc
,member I-C 2x4-1 row at 0-9-0 oc,member H-D 2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to
ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Unbalanced floor live loads have been considered for this design
4)As requested,plates have not been designed to provide for placement tolerances or rough handling and erection conditions It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0 131"X 3")nails
Strongbacks to be attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard ,`9 4 WASH `tJ
1)Dead+Floor Live(balanced):Lumber Increase=1 00,Plate Increase=1.00
Uniform Loads(pin 0
Vert:G-J=-10,A-F=-100
Concentrated Loads(lb)
Vert:F=-891 E=-852 D=-1461 K=-1461 L=-1461 M=-326
r0�p0 kF 51398
A GIs 1>rR
�SS10 AL
May 8,2017
,&WARNING-verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.1010312015 BEFORE USE. '
Design valid for use only with MiTek®connectors-This design is based only upon parameters shown,and is for an individual building component,not
a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing M iTe k'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane
Safely Information available from Truss Plate Institute,218 N Lee Street,Suite 312,Alexandria,VA 22314. Suite 109
rus He!hts CA 95610
110
�W � a m D Ncn
c y -� o m co �� M m X m m
Z CA
C7�G7Wp�z7 W m ° �' n
A ° D O
� v�a�•�Do C 9a p
as?DG7n�� v �c min °c a Z s o f,� �'D o m ° �7 'I m_ v Dpo C. Z
W° ° 7 N N O 3 g, n na CD C) CD N n fD C y j C N CO 0 0� d"O_3 Cn 7 D
O N C1 O �"CO N•N O O O n .C. N r CD O S fD < CD N CD y A C�< > y N Z
°CL n.17° a O (D O y N O 7 CD O N 3 in Lu O a 0, p N 'O N v
�o
a v CD g m ; � N In Q �� mCD D -o m-0
0c
N 0.ORmO C Q O N •C (D 0 CD CS-N d mO
CL
mf ONW O N OO C
CDN O' N D 0 0 ' ndsn
>
mn D
LD N 7 C) N 7 CD n N CD ° N fD N N C S N =•• C
Cv Q O n O C N N m = CD O 7 0 X O N O O_ 7
CD =' N S N.c<� N c° o.= N Cn
o n N o N O CD nni N N Z
r'CD 3•o O•� (U 7 d 7 C N 7• CD O CD Cn
07 CO .O.CT 7 0.0 N N sU C -�CD CD X
C (� N
p 7 N E;O N =r <
7 C CD fn N
Cn m c m m n v z 1 n TOP CHORD
cx x�0
x v 93 �' w �� n 0 3O mOz 00
m v o Q N N w O oD A rc-
Cp N' 7 N C CD O W � O m y m z CA
S Cn Cn J W C .G 0 -O D o
CD CD a (D m TJ n L D 1;
N a W CD N m- r Z m m CA
o � 39 oa ��CD p � v Mm s Np
co
X yCID < �N w� `" v mm cm W v
D y N v _� _
y C CD CDCD m N -0 A 1 r O O N n
cn �� a� ° �� O o �� 0 m _CD
co
CD � ° cp < z z 3 = U) v y.
CD (D alco'> > > 4 00 r, -1 0 m O m D Cl)
N � v a 0o y Dm � � 0 fN
c0i o � m -i m v ", o
A x < a N w mr o
p j 3. co m om N rF
N z _ CD
< - C 3 -I A VW3-6f° 3 O T m cra z mCD N .'0 0 CD
w < ZCD mOCD N � 0 mo C�z N S � CJi
a -V CD 0 m TOP CHORD
N fI) OD �l W N A W N
O Cn W �l O Ul A W N O
D p m m m C g o CO) o m y w C� c C y C �•O o`_o'v C1 m a y Z c 3 F n D O
cn0 on o.<-',CD ° mx mvo mm3 an 3-03 mU vo m0 M'm omo . < m3nc ) a C
�c g Co' fD o o °i o c o 5-0 " v Doi m Q o Q m - CD r- m m fD m o N
c 2� m N n 3 o m D m m N m o n < >>-0 m CD m m 3 D ° 2 v d (O CD
_�N C°i N N a D.C-- O �' J a a� C a N R II-' =1 X O N y a ti 3 _ m X y C y 0
pc ��0 9'�� o �� a on �y �n m�. nm m� Qm 3c @3 � m m��. �•m c`D�50' � � O 0 Y•
c MD',
m-o a m 'o my °.1C �' y 3m Woo Ow CD �m mm `" N2m mn E. Cdi`� vc_ T� O� CD
�.'y" d N n 7 D),� a y f0�•CD ° O 0 0 CD 0 7 C m v
3 RrW mm� m 9 � toM oQ c ° o� d� �> > ccm a� � fD CD9o0 0,� CD O
CD
nJ �O O�� n �� NC �y �_ry C7 .0
Jyq RCN 0m :3 (� Q 1
(p (p (p Di y o •m' m 0 iw
W3 m $a Ny Ju" mW 0O �W C mC as °:a oN n�N 1 am RD <a 0 0
_ c 0 m 0 > > C7
n. N 0.--3
--3 C 3 N y m �� O U M CDC d K 0 m ,1�, 41�.41 E ID Cl. m f0
d � �� m � m m v �� Qm ' ��{� my 34 fF' Dno 0 vo �mc� O 0
fD G,CD O N N 3 >• 01 n CD y CO m O d ti Z N N 0 n CD G a 3 A 0 m ° — C
m 10 fil N CD a O N a °N N m C W a 2 N 4 �1 d N 2-
0 .. .,
m 3'- m m T. 0 CD 5: a o t7 a <io m Z 0 - o'� o-N m m Q ` Q
o v3 �v a o mc' y ' :N. >> Cn� �� 03 m S 0 0m< m O n
m o m c.< N
-•_' N N N N o f=il >'n30 m j CD
a= g ID ��< 'pl n 0 y � a� -p1 CD n
0 m F c o F, v m o -0 D!y a v m a d o �v Q 2Cn Cu y a 3 fR
y n C7 N ,�' CD
O N fa 3 @ V .y+ R N C. VI n Cn-
F p`< 08 ID c -o. ��� m m r�i+ �N fa�' 3 a '� m m ? m � CD m m io �
3 >O y CD 2 p m a m O �j. Q m �t0 < 3' W-
md ca v 0 m a mQ n a m 0 c) O
-_ y Q o CD 10 y vim ?CD m 0 z CD
3
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
Plan 2514
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All climate Zones
R=value U-Factor
Fenestration U-Factor" n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGC ' n/a n/a
Ceiling" 49J 0.026
Wood Frame Wal19" 21 int 0.056
Mass Wall R-Value' 21121" 0.056
Floor 301 0.029
Below Grade Wall' 10/15/21 int+TB 0.042
Slab--R-Value& Depth 10,2 ft n/a
'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit In a residential building shall comply with sufficient options from Table R406.2 so as to achieve
the following minimum number of credits:
1.Small Dwelling Unit: 1.5 credits
❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500
square feet.
n2. Medium Dwelling Unit: 3.5 credits
All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies shall
require 2.5 credits.
❑3. Large Dwelling Unit: 4.5 credits
Dwelling units exceeding 5000 square feet of conditioned floor area.
❑4. Additions less than 500 square feet: .5 credits
Table R406.2 Summary
Option Description Credit(s)
1a Efficient Building Envelope 1a 0.5 ❑
1b Efficient Building Envelope 1b 1.0 ❑
1c Efficient Building Envelope 1c 2.0 ❑
1d Efficient Building Envelope 1d 0.5 ❑
2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑
2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑
2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑
3a High Efficiency HVAC 3a 1.0 0 1.0
3b High Efficiency HVAC 3b 1.0 ❑
3c High Efficiency HVAC 3c 1.5 ❑
3d High Efficiency HVAC 3d 1.0 ❑
4 High Efficiency HVAC Distribution System 1.0 0 1.0
5a Efficient Water Heating 5a 0.5 0.5
5b Efficient Water Heating 5b 1.0 1.0
5c Efficient Water Heating 5c 1.5 ❑
5d I Efficient Water Heating 5d 0.5 ❑
6 lRenewable Electric Energy 0.5 *1200 kwh 0.0
Total Credits 3.50
*Please refer to Table R406.2 for complete option descriptions 0, e i V e �
?"Ilv4fi
C � o. ��. .
•,�S,
�,
Table R402.1.1 Footnotes
For SI: 1 foot.=304.8 mm,ci .=continuous insulation, int.=intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is
less than the label or design thickness of the insulation,the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration.
"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB"shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior
of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity
insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement
wall.
d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Reserved.
e Reserved.
h Reserved.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
Reserved.
k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38.
Reserved.
m Int. (intermediate framing)denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
Window, Skylight and Door Schedule
Project Information Contact Information
Plan 2614
Width Height
Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Exempt Swinging Door(24 sq. ft. max.) 1 0.01 0.00
Exempt Glazed Fenestration (15 sq, ft. max.) 1 0.01 0.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Foyer 0.30 1 3 6 20.0 6.00
0.30 1 2 6 17.8 5.33
Guest 0.30 1 3 5 15.0 4.50
Great Room 0.30 1 5 5 25.0 7.50
Dining 0.30 1 6 16 "' 41.0 12.30
Great Room 10.30 1 3 5 15.0 4.50
Master Bedroom 0.30 1 5 5 25.0 7.50
Stairs 0.30 1 2 2 4.0 1.20
Bedroom 2 0.30 S 3 5 15.0 4.50
Bedroom 3 0.30 1 15 1 5 1 1 25.0 7.50
Bonus Room 10.30 1 3 5 15.0 4.50
Bedroom 4 0.30 1 2 2 4.0 1.20
0.30 1 3 5 15.0 450
0.30 0.01 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.30 0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.01 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
o.o 0.00
0.0 0.00
0.0 0.00
Sum of Vertical Fenestration Area and UA 236.8 71.03
Vertical Fenestration Area Weighted U= UA/Area 0.30
Overhead Glazing (Skylights)
Component Width Height
Description Ref. U-factor Qt. Feet inch Feet inch Area UA
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.01 0.00
0.0 0.00
Sum of Overhead Glazing Area and UA 1 0.01 0.00
Overhead Glazing Area Weighted U= UA/Area 0.00
Total Sum of Fenestration Area and UA (for heating system sizing calculations) 236.81 71.03
Simple Heating System Size:Washington State
This healing system sizing calculator is based on the Prescriptive Requirements of the 2015 Washinqton State Energy Code(WSEC1 and ACCA Manuals
J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads
rho glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30.
The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some
values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at
(360)956-2042 for assistance,
Pip act Information Conlact Information
Plan 2514
Heatina System Type: O All0therSystems Q Heat Pump
To see detailed instructions for each section,place your cursor on the word'Instructions".
Deslan Temperature
Instructions Design Temperature Difference(AT) 47
tm,.wd.
AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 2.514
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 9.3 23,380
Glazing and Doors U-Factor X Area = UA
Instructions
0.30 237 71.10
Skylights U-Factor X Area = UA
Instructions 0.50
Insulation
Attic U-Factor X Area = UA
Instructions R 99 0,026 1.513 39.34
` � J
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions Select R Value No selection ...
Above Grade Walls(see Figure r) U-Factor X Area UA
Instructions R-21Intermediate 0.056 2,670 149.52
Floors J U-Factor X Area UA
InstructionsLill R-30 0.029 1.513 43.88
� J
Below Grade Walls(see Figure 1) U-Factor X Area UA
Instructions
No Below Grade Walls In this project. � -"- ^-
Slab Below Grade(see Figure 11 F-Factor X Len th UA
Instructions { i saw comiticang ^-- No selection --
Slab on Grade(see Figurer) J F-Factor X Length UA
Instructions
No Slab on Grade in this project.
Location of Ducts
Instructions Duct Leakage Coefficient
bil Conditioned Space — +r
J 1.00
Sum of UA 303.84
Envelope Heat Load 14,280 Btu I Hour
Figure 1. Sum ofUAXAT
Air Leakage Heat Load 11,868 Btu/Hour
Volume 0.6XATX,016
AbeveGrade Building Design Heat Load 26,148 Btu I Hour
Air Leakage r Envelope Heat Loss
Building and Duct Heat Load 26,148 Btu I Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 36,607 Btu I Hour
• Building and Duct Heat Loss X 1,40 for Forced Air Furnace
Building and Duct float Loss X 1,25 for Heat Pump
(o�igur»
NASH &ASSOCIATES
ARCHITECTS
PLAN 2 514
BEAM, LATERAL &
SEISMIC CALCULATIONS
-GIaTER "
E�}tCHI'
Yti :Y )MAS NASH
r�STATE OF WASHINGTON
Recceived
OCT 1 . 7017 2015 IBC
wo w JULY 1, 2016
8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW,NASH-ARCHITECTS.COM
( �; a'.
„�,'r •� 7
CLIENT:
_
NASxtASsOQATES BEAM DESIGN DATA PROJECT:
ARC141TF,CTS DATE:
NAME:
Roof Loads:
LL 25 N/sf
DL 15 #/sf
Total 40#/sf
Unless Noted Otherwise
Floor Loads:
LL 40#/sf
DL 10 #/sf
Total 50#/sf
Deck Loads:
LL 60#/sf
DL 10 #/sf
Total 70#/sf
Soil• 1500 PSF Min.
Concrete: Per IBC 15
Masonry. Per IBC 15
Steel: Per IBC 15
Wood: Per IBC 15
Nailing: Per IBC 15
4" Beam: Douglas Fir #2
fv = 180
fb = 900 PSI
E = 1,600,000
6" Beam: Douglas Fir #2
fv = 170
fb = 875 PSI
E = 1,300,000
Joists & Hem Fir #2
Rafters: fv = 150
fb = 850 PSI
E = 1,300,000
Glu—Lam Beams:
fv = 240 PSI
fb = 2.400 PSI (reduced by size factor, CF01C)
E = 1,1300,000
8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
PLAN 2514
BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622
RB-1 Date: 10/24/16
Selection 4x 10 DF-L#2 Lu=0.0 Ft
Condition NDS 2015
Min Bearing Area R1=3.4 in' R2=3.4 in' (1.5)DL Defl= 0.02 in
Data Beam Span 5.0 ft Reaction 1 LL 1313# Reaction 2 LL 1313#
Beam Wt per ft 7.87# Reaction 1 TL 2120# Reaction 2 TL 2120#
Bm Wt Included 39# Maximum V 2120#
Max Moment 2650'# Max V(Reduced) 1466#
TL Max Defl L/240 TL Actual Defl L/>1000
LL Max Defl L/360 LL Actual Defl L/>1000
Attributes Section(m') Shear(in') TL Defl(in) LL Defl
Actual 49.91 32.38 0.04 0.02
Critical 29.44 12.22 0.25 0.17
Status OK OK OK OK
Ratio 59% 38% 15% 12%
Fb(psi) Fv(psi) E(psi x mil Fc (psi)
Values Reference Values 900 180 1.6 625
Adjusted Values 1080 180 1.6 625
Adiustments CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress NIA
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL: 525 Uniform TL: 840 =A
L Uniform Load A
0
R1 =2120 R2=2120
SPAN=5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2514
BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622
RB-2 Date: 10/24/16
Selection 4x 10 DF-L#2 Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1=3.4 in' R2=3.4 in (1.5)DL Defl= 0.02 in
Data Beam Span 5.0 ft Reaction 1 LL 1313# Reaction 2 LL 1313#
Beam Wt per ft 7.87# Reaction 1 TL 2120# Reaction 2 TL 2120#
Bm Wt Included 39# Maximum V 2120#
Max Moment 2650'# Max V(Reduced) 14664
TL Max Defl L/240 TL Actual Defl L/>1000
LL Max Defl L/360 LL Actual Defl L/>1000
Attributes Section in' Shear(in') TL Defl (in) LL Defl - -
Actual 49.91 32.38 0.04 0.02
Critical 29.44 12.22 0.25 0.17
Status OK OK OK OK
Ratio 59% 38% 15% 12%
Fb(psi) Fv(psi) E(psi x nul) Fc L (psi)
Values Reference Values 900 180 1.6 625
Ad'usted Values 1080 180 1.6 6_25
Adjustments CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL:525 Uniform TL: 840 =A
Uniform Load A
R1 =2120 R2=2120
SPAN=5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2514
BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622
B-1 Date: 10/24/16
Selection 3-1/8x 9 GLB 241744 DF/DF Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1=6.6 in2 R2=6.6 in' (1.5)DL Defl= 0.06 in Recom Camber=0.10 in
Data Beam Span 6.0 ft Reaction 1 LL 2775# Reaction 2 LL 2775#
Beam Wt per ft 6.83# Reaction 1 TL 4281 # Reaction 2 TL 4281 #
Bm Wt Included 41 # Maximum V 4281 #
Max Moment 6421 W Max V(Reduced) 3210#
TL Max Defl L/240 TL Actual Defl L/504
LL Max Defl L/360 LL Actual Defl L/914
Attributes Section(in') Shear(ir)') TL Defl (in) LL Defl
Actual 42.19 28.13 0.14 0.08
Critical 32.10 20.06 0.30 0.20
Status OK OK OK OK
Ratio 76% 71% 48% 39%
Fb(psi) Fv(psi) E(psi x mil Fc (psi)
Values Reference Values 2400 240 1.8 650
Adjusted Values 2400 240 1.8 650
Adjustments Cv Volume 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL:925 Uniform TL: 1420 =A
[ Uniform Load A
R1 =4281 R2=4281
SPAN=6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2514
BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622
B-2 Date: 10/24/16
Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 5.6 in' R2=2.6 in' (1.5) DL Defl= 0.02 in Recom Camber--0.03 in
Data Beam Span 5.0 ft Reaction 1 LL 2423# Reaction 2 LL 1215#
Beam Wt per ft 6.834 Reaction 1 TL 3666# Reaction 2 TL 1658#
Bm Wt Included 34# Maximum V 3666#
Max Moment 3013'4 Max V(Reduced) 2633#
TL Max Defl L/240 TL Actual Defl L/>1000
LL Max Defl L/360 LL Actual Defl L/>1000
Attributes Section(in') Shear(in2) TL Defl(in} LL Defl
Actual 42.19 28.13 0.05 0.03
Critical 15.07 16.46 0.25 0.17
Status OK OK OK OK
Ratio 36% 59% 19% 17%
Fb(psi) Fv(psi) E(psi x mil Fc1(psi)
Values Reference Values 2400 240 1.8 650
Adiusted Values 2400 240 1.8 650
Adiustments Cv Volume 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Load
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
1313 B=2120 1.0 885 H= 1370 0 1.0
360 1=450 1.0 5.0
H
Pt loads:
0
R1 =3666 R2= 1658
SPAN=5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2514
BeamChek v2016 licensed to:Nash Jones Anderson Architects Reg#6464-622
GB-1 Date: 10/24/16
Selection 5-1/tax 19-1/2 GLB 24F-V4 DF/DF Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 17.6 in'R2= 13.9 in2 (1.5) DL Defl= 0.19 in Recom Camber=0.28 in
Data Beam Span 16.0 ft Reaction 1 LL 7544# Reaction 2 LL 6185#
Beam Wt per ft 24.28# Reaction 1 TL 11440# Reaction 2 TL 9053#
Bm Wt Included 389# Maximum V 11440#
Max Moment 46400'# Max V(Reduced) 9093#
TL Max Defl L/240 TL Actual Defl L/440
LL Max Defl L/360 LL Actual Defl L/769
Attributes Section(in3) Shear(in') TL Defl(in) LL Defl
Actual 324.80 99.94 0.44 0.25
Critical 237.01 56.83 0.80 0.53
Status OK OK OK OK
Ratio 73% 57% 55% 47%
Fb P_S11 Fv(psi) E(psi x mil) Fc (psi)
Values Reference Values 2400 240 1.8 650
Adjusted Values 2349 240 1.8 650
Adi,ustments Cv Volume 0.979
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
1313 B=2120 2.5 925 H= 1420 0 2.5
1313 C=2120 7.5 400 1=500 2.5 7.5
1838 D=2964 10.0
925 K= 1420 7.5 10.0
440 L= 550 10.0 16.0
K
1
I
Pt loads:
R1 = 11440 R2=9053
SPAN = 16FT
Uniform and partial uniform loads are lbs per lineal ft.
y
I
i
CLIENT:
NASH=ASSOCIATES WIND AND 5E15MIG DE51GN DATA PROJECT:
E(A.s PER 2015 IBC DATE:
NAME:
WIND DESIGN CRITERIA ^
DE516N PER A50E 7-10
I. NOMINAL/ULTIMATE WIND SPEED V/asd /Vult 85/110 mph
2. RISK CATEGORY 11 1.00
3. WIND EXPOSURE CATEGORY "B"
4. INTERNAL PRESSURE COEFFICENT +/-55
5. COMPONENTS AND CLADDING
DESIGN PRESSURE +/- 16 psf
BUILDINGS,STRUCTURES, AND PARTS THEREOF SHALL BE DESIGNED AND
CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN,LOAD,AND RESISTANCE
FACTOR DESIGN, ALLOWABLE 5TRE55 DESIGN,EMPIRICAL DESIGN OR CONVENTIONAL
CONSTRUCTION METHODS, AS PERMITTED BY THE APPLICABLE MATERIAL CHAPTER,SECTION 1604.1
BUILDINGS,5TRJGTURE5,AND PARTS THEREOF,SHALL BE DESIGNED TO WITHSTAND WIND LOADS
AS DEFINED IN SECTION 1609 AND ASCE T-10
SIMPLIFIED METHOD TO BE U5ED FOR WIND DESIGN PER A50E 1-10,SECTION 275
(BUILDING FIEIGFI'f 15 LE55 THAN 160 FEET)
110 MPH ULTIMATE WIND SPEED
USE Iqb P5F PER TABLE 2-7.6.1 "EXPOSURE B"
WOOD DE516N PER 5EGTION5 2304-2306.51RUCTURE5 USING WOOD SHEAR WALLS
AND DIAPHRAGMS TO RE515T WIND,SEISMIC,AND ALL OTHER LATERAL LOADS SHALL
BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AF d PA 5DPW5 AND PROV15IONS
OF SECTIONS 2305-2306
5E15MIG DESIGN DATA
DESIGN PER A5GE 1-10/5EGTION 1613
I. SEISMIC IMPORTANCE FACTOR la 1.00
2. SHORT PERIOD ACCELERATION 55 ibb *see footnote at bottom of pace
3. 1 SECOND ACCELERATION 51 OA4b *see footnote at bottom of pogo
4.51TE CLA55 D (default class per IBC)
5.SPECTRAL RESPONSE COEFFICENT Scs 0A 12 *see footnote at bottom of page
6. SPECTRAL RESPONSE COEFFICENT Sew 0 14b *see footnote at bottom of page
'1. SEISMIC DESIGN CATEGORY D
8. SEISMIC FORGE RESISTING SYSTEM PLYWOOD SHEAR WALLS
q. DE516N BASE SHEAR (see seismic calculations)
10. SEISMIC RESPONSE COEFFICENT CIS 0.13
II. RESPONSE MODIFICATION FACTOR R 6.5
12. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORGE
15. RISK CATEGORY II
THE ANCHORAGE OF WALL5 SUPPORTING GONSTRUGTION SHALL BE 8E
DESIGNED IN AGGORDANGE WITH ASCE -1-10, SECTION 12.11.2
IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C-F,COLLECTOR ELEMENTS
AND THEIR CONNECTIONS TO VERTICAL ELEMENTS SHALL BE DESIGNED TO RE51ST
MAXIMUM EFFEGT5 AS SPECIFIED IN ASGE -1-10,SECTION 12.10.2.1
BASE SHEAR V= (F SDS/R) W
ANCHOR BOLT5e 5/8" DIA X 10",A50-1 OR BETTER W/7 MIN. EMBEDMENT.V= 1104#/BOLT
PER U565,THE MAXIMUMS,IN THE STATE OF WASHIN6TON 15 0348. ALL SEISMIC DESIGN VALUES USED
IN TH15 ANALY515 ARE BASED UPON THIS NUMBER SINGE 5115 LE55 THAN 0.75,THEN USE SEISMIC CATEGORY
D IF RISK CATEGORY 15 I, II,OR III
8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
�L
i
i
LLI
❑ ❑
❑ 100
❑❑❑ ,
a-
0.
i
i
i
i
i
i
i
i
i
i
I
i
i
� � N
� k
N
V
k
t 13
9 /d -
�s
M
^1_
'Al
Li
1
r^ �
V
O �`
LATERAL CALCULATIONS CLIENT:-
-�I NASH&ASSOCIATO PROJECT:
WIND WORK3HEET —
n DATE:
85 MPH/110 MPH= NOMINALAJLTIMATE WIND SPEED NAME:
19.6 P5F
FRONT ELEVATION LEFT ELEVATION
REAR ELEVATION _ RIGHT ELEVATION
LOCATION TOTAL SHEAR F'ORCE SHEAR UNIT SHEAR
W z H z (see chart for wind pressure WALL SHEAR WALL
® specified height) LENGTH (ft) (#/ft) TYPE
l �P 17,5xakrl, 41
30?-7 37 r 63
.Nax( 51 (o
?c-f 3 q 3D l m
13u iP ��� xgXr 4�� ) ;I yj -
/7. s-x-1 x «t 30'Y l
r� yp � lS� P/��� r
Z'yl �i�s'�G x r q,� � -�-a o 6 �/
�Z�xR xag�61 4- 3_�L—�
(3
8003 118th AVE NE Kirkland, WA 98033 (425) 628-4117
WWW.NASH—ARCHITECTS.COM -
CLIENT:
11 HASH-ASSOCIATES SEISMIC ANALYSIS PROJECT:
T (:T S DATE:
NAME-7
1
Weight of Building:
Root Assembly.
Asphalt Shingles - 2.00 /it Cedar Shakes - 2.25#/ft Tile - 9.50#/it
Felt - 0.15 #/it Felt - 0.15 #/ft Felt - 0.15 #/it
1/2" Plywood - 1.50 #/it 1/2" Plywood - 1.50 #/ft 1/2" Plywood - 1.50 #/it
Trusses A 24" o.c. - 1.75 #/it Trusses ® 24" o.c. - 1.75 #/lt Trusses 0 24" o.c. - 1.75 #/ft
R-38 Insulation - 2.35#/ft R-30 Insulation - 2.25#/ft R-30 Insulation - 2.25#/it
1/2" GWB Ceiling - 2.00#/it 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft
Total 9.75#/it Total 9.90#/it Total 17.90#/it
Use 10.00#/it Use 10.00#/it Use 18.00#/it
lot do 2nd Floor Assembly:
Caret / Pad - 0.60#/ft Hardwood - 2.50#/ft
3/4 Carpet
Plywood - 2.50#/it 3/4" T&G Plywood - 2.50#/it
2x10 @ 16" o.c. - 2.30#/it 2x10 0 16" o.c. - 2.30#/ft
1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/it
Total 7.30#/it Total 9.30#/it
Use 10.00#/it Use 10.00#/ft
Interior Wall Assembly: Exterior Wall Assembly:
1/2" GWB - 2.00#/it 3/4" Wood Siding - 2.30#/it
2X4 ® 16" o.c. - 1.10 #/It 1/2" Plywood - 1.50 #/ft
1/2" GWB - 2.00#/it 2x6 ® 16" o.c. - 1.37 #/it
Total 5.10 #/it R-21 Insulation - 2.10 #/ft
Use 8.00#/it 1/2" GWB - 2.00#/it
Total 9.27#/it
Use 10.00#/it
4" Brick Veneer - + 3.20#/it
8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW.NASH-ARCHITECTS.COM
CLIENT:
NASHLml
QATES SEISMIC ANALYSIS PROJECT_
A R F E,"TS DATE:
NAME:
2
SEISMIC:
V = (C-) (Wdl) (Plywood)
2nd Level:
Roof: (Asphalt / Cedar Shake) 10#/ft X .50 r sf = I�51)
or (Tile) 18#/ft X __sf =
Exterior Walls: L x 10#/sf x 1/2 (h) ��O
/&I N/0 k y O o (E2)
Interior Walls: L x 8#/sf x 1/2 (h)
�Oxo vq S�yD cI�
TOTAL: = 2&a-7 c
1st Level:
Roof: (1st Floor Roof) 10#/ft X Sf =_
2nd Floor. 10#/ft X /K 3 _sf =
Exterior Walls: (E2) ++ L x 10#/sf x 1/2 (h) /�
6�t �� q /- 1�v7l�(0 k-c-f I377✓ EI)
Interior Walls: (I + L x 8#/sf x 1/2 (h)
SNK04- le0x (d Kbf, � 83 �o cI1)
TOTALn _✓_ !Q 3 Cf o ,
Basement:
1st Floor. 10#/ft X -sf =
Exterior Walls: (El) + L x 10#/sf x 1/2 (h)
Interior Walls: (I1) + L x 8#/sf x 1/2 (h)
TOTAL
8003 119th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
CLIENT:
NA it C 141 E C TES SEISMIC ANALYSIS PROJECT.
ARC;FIITF.C"i'S DATE:_
NAVF-
3
BASE SHEAR:
5A5E 5HEAR V= (P 5.,/1W W
V= F (AIZ/65= .149
LEVEL 2: Will ?G!W f`e/ # x 0.149 = yd' 0
LEVEL 1: Wdl J(O a�-,`/ x 0.149 = Sf 'y Z
TOTAL:- Wdl & 31 x 0.149 = �� y 2 (V)
Dead Load Hei ht Moment Shear ® St'
r
Level Fx = [(Wd1)(h)f V Remarks
(Wdl) (h� (Wdl
(Wdl)(h)
z N � �� �lSLlr2 y�iu, 7(�til
f
S 3�
36 3&KCg, 47-
Z
C�o S
Total 63, to U 11,01 Z
5003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
NASH&ASSOCIATES
SEISMIC ANALYSIS PROJECT:
DATE:
NAME:
4
x ~
cr
a �-
0A �
x z �-
�za ti ,� S N
0� 0 M M o
c�
E-+
x
v�
x -
n
a
- ti ti Cv 5
zwo
�wm - -
� N
W
,r 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW. -ARCH
CLIENT:
NAS ( I III- Q:-I'S SEISMIC ANALYSIS PROJECT:
A r,c III i � L c:�l'S DATE: — — —
NAME:
5
Redundancy Factor (p):
1. Maximum allowable wall shear for p<=1
Vumax = (2)(Vacestory)/Ab 1/2
`? fC�lry2
2, Maximum actual shear
Vmax = Largest seismic wall shear
3. p = 2—[2(Vaccstory)/(Vumax)(Ab 1/2)
Z I �C4c�( Z
� K613C
� r , I
o/Z
W vv//
r�0� Wj
8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
1
c
Permit#: 1689
Permit Date: 10/12/17
Permit Type: RESIDENTIAL SINGLE FAMILY
Project Nam e Gregory Park
Applicant Nam a LGI Horn cs -Washington, LLC
Applicant Address: 9026 168th Street NE
Applicant, City, State, Zip: Arlington,WA98223
Contact: Matt Adam s
Phone: 425-785-0797
Em al: m at.adam s@lgihom cs.com
Scope of Work: New SFR
Valuation: 309450.70
Square Feet: 2894
Num ber of Stories: 2
Construction Type:
O xupancy G ioup:
ID Code:
Permit Issued: 10/27/2017
Permit Expires:
Form Permit Type:
Status: LASERFICHE
Assigned To: Kristin Foster
Property
Parcel# Address L egal Description O wrier Nam e Ovner Phone Zoning
LGI HOMES-
01166900007200 8 919 169th Street NE WASHINGTON Residence
Single Dam iy
-Detached
LLC
Contractors
Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License#
LGI HOMES- 12951 BELRED CONSTRUCTION Labor and LGIHOHL857MB
WASHINGTON LLC RD#150 CONTRACTOR Industries
Inspections
Date I nspection Type D escription S cheduled Date C om Iieted Date I nspector S tatus
11/30/2017 R20.SFR/DUPLEX ComOeted
FINAL
Plan Reviews
Date R eview Type D escription A ssigned To R eview Status
10/12/2017 RESIDENTIAL SINGLE
FAMILY
10/12/2017 RESIDENTIAL SINGLE BUILDING
FAMILY
Fees
Fee D escription N otes A m cunt
Building Perm i T able 4-1 $3,076.58
Building Plan Review T able 4-2 $1,999.78
Forced Air Heat f ee per Btu $25.00
Gas Piping/Units E nter#of units $10.00
Mechanical Fee(Enter Fixture Fee) $25.00
Mechanical Base P erm i Fee $25.00
Park-Com m nity SF S ingle Fam iy $1,662.00
Plum ling Base Perm i Fee $25.00
M echanical Com m mial Perm i T able 4-7;Per Unit 1 6 @$12 $192.00
Processing/Technology $25.00
State Surcharge- 1 st DU R esidential- 1 st Unit $4.50
Traffic Mitigation-SF S ingle Fam iy $3,355.00
Wier Heater(Tank) $25.00
Total $10,449.86
Attached Letters
Date Letter D escription
10/24/2017 Building Perm i
Paym arts
Date Paid By D escription P aym a►t Type A ccepted By A m aunt
10/24/2017 LGI Hom cs-Washington,, Check#5741 K ristin Foster $8,450.08
LLC
10/24/2017 LGI Hom 6-Washington,, Check#5740 K ristin Foster $1,999.78
LLC
O utstanding Balance $0.00
Notes
Date Note C reated By:
10/12/2017 Lot 72-Palix Kristin Foster
Uploaded Files
Date File Nam e
10/27/2017 2736501-1689 Issued Perm i.pdf
10/12/2017 2694361-1689 Application.pdf
10/12/2017 2694362-1689 Site Plan.pdf