Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3617 172ND ST NE_BLD1673_2026
�1ly o� COMMERCIAL MECHANICAL • PERMIT APPLICATION ��ilvGSp Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: ❑ New Installation �✓ Replacement ❑ Alteration Project Address: 2313 SR 530 Arlington, WA 98223 Parcel #: Replacing walk-in box and refrigeration equip. 2 Project Description:condensinq units and 4 evap coils. Cond units on Valuation:491768 Owner: My Goods Market Phone#:Unknown Address: 2313 SR 530 City: Arlington State:WA Zip:98223 Email Address: Unknown ryan an quis Contact Person: Phone #: 253-341-8402 Address: 5102 20th St E Suite 102 City:Fife State: WA Zip: 98424 Email Address:bsandquist@ru-inc.com Contractor Name:Refrigeration Unlimited, Inc Phone #: 253-474-3100 Contractor Address: 5102 20th St E Suite 102 City: Fife State:WA Zip: 98424 Email:bsandquist@ru-inc.com Contact Person: Bryan Sandquist Contractor License Number: refriui011ks Expiration: 2018 Please indicate type of number of appliances: FURNACE CONDENSING UNIT 2 GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will b rules and regulation of the fate of Washington. Applicants Signature: f�a Date 09/28/2017 Applicants Printed Name: Bryan Sandquist FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 1 of 1 Job Name:. Prepared By:. TRA/VE Unit Tag:YSC048G3RMA21 ' Quantity:1 Trane Precedent Gas/Electric Packaged Rooftop Unit •vmlew-YS&"SG3R iorllrr slraalrrrrslrli00 Application Unit Size TSupply Fan ExtsnW61mensions pn f W EER IEER/SEER External gas�ea9' 4 Ton(048) Airflow Static Height VVidth Length Minimum Maximum 12.0 EER 14.00 1600 cfm 0.500 in H2O 3.41 ft 3.69 ft 5.82 ft 492.0 lb 348 kg Fresh Air Selection Low Leak Econ-dry bulb 0- 100/o/ber rel 3p Supply Fa n1l)rive/ MotorType Standard drive motor Motor Type r-1.-+, PanafwT hers Standard condenser coil Unit Electrica�—I— V*k@9Wpint}RWW t 208-230/60/3 MCA 25.40 A >\, MOP 35.00 A , Unit Controls,Microprocessor controls 3ph Communications Option Without communications System Monitoring Controls 1 Without system monitoring controls System Monitoring Controls 2 No monitoring controls Entering Dry Bulb 80.00 F Capacfty Entering Wet Bulb 67.00 F Gross Total 48.90 MBh AmblentTeMp 95.00 F Gross Sensible 38.78 MBh Leaving Coll Dry Bulb 56.90 F Met Total 47.41 MBh Leaving Coll Wet Bulb 56.90 F Not Sensible 37.29 MBh Leaving Unit Dry Bulb 58.78 F Fan Motor Heat 1.49 MBh Leaving Unit Wat Bulb 57.63 F Refrig Chargetircuft 13.1 lb Rofrigeration System Options Leaving Dew Point 56.91 F Heating Section Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 65.60 MBh Output Heating Capacity with Fan 67.50 MBh Heating EAT 70.00 F Heating LAT 108.20 F Heating Temp Rise 38.20 F CITY ®F ARLINGTON Received BUILDING DEPARTMENT /DPP 'VED OCT 06 2011 2017-06-02T16:51:23 DATE O BY � pap �11 NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR Y T Jab Name: Prepared Byy:. Unk Tag:YSC04603RMA21 Quantity!I TOP PANEL EVAPORATOR CONDENSER FAN SECTION ACCESS PANEL— CONDENSATE DRAIN(ALT) 3/4'-4 NPTOIA.HOLE r OHIIEN''XR COIL Al 4 19" 27 9116' NIT CONTROL WIRE 716'DU\HOLE 42114' ERVICE GAIT GE PORT ACC ESS 1 30r 0W 40 LE NIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE 1/r NPT OAS CONNECTION CONDENSATE 23 1/T N V NOTES: 1 TH RU-TH E BASE OAS AND E LECTRICAL IS NOT STAND ARD 0 N ALL U N ITS. 2.VERIFYWEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION r---- ___ I I I I I I I I I I RETURN 2P SUPPLY I I 1 I ...... — _4• Ls I? g 114' 14' L35'Ml PLAN MEW UNIT DIMENSION DRAWING RETURN HORIZONTAL 4078' 231/4' SUPPLY 1431C AIR FLOW 201f4' 9SB' 4 Sf6" 11 1N' 6 7B' 13 1/4' 3 3/16' 4 N4' 97B' 59/16' CONDENSATE 7 SI8' 44 114' PACKAGED GAS/ELECTRICAL DIMENSION DRAWING 2017.08-02T16:51:23 Page 3 of 11 Job Name:. E+ Prepared Byy:. 2 Tag:YSC048G3RMA21 OuonNly'1 ELECTRICAL/GENERAL DATA GENERAL HEATING PERFORMANCE Model: YSCO480 Oversized Malor HEATING-GENERAL DATA Unit Operating Vbllsge: 187-253 MCA: NIA healing Model: Medium U nit P rlm ary Voltage: 205 MFS: NIA H eUing Input(BTU): 80.000 Unit Secondary Vessgs 23D MCB: NIA M aelng Output(BTU); 05,000 Unit H anr. 60 Unit P ham: 3 N o.Stagers: 2 No.Sieges 1 EERISEER 12.OM4 0 Standard M otor Field Installed Oversized Motor Gas INetlimeaure MCA 2S4 MCA NIA N stoml Osa(MiNM k). 4.5M 4.0 MFS: 35.0 MFS: NIA LP(M hFAa)0 11.0114.0 MCB: 3S.0 MCB: NIA Gas Pipe Connection Slze: 11r INDOOR MOTOR Standard Motor Oversized Motor Field Inatslad Oversized Molor Mum bar. 1 Number. MIA Number: NIA rs Hoepower. 10 Horsepower. NIA Homispower NIA M otor Speed(RP M). — M otor Speed(RP M k NIA Motor Speed(RPM I NIA Phase 1 Ph*" NIA Phase NIA FuOL.oadAmp& 69 FWILosdAmp& NIA Full Load Amp& MIA LodedRotorAmpa _ LOdko d Rotor amp. MIA Locked RotorAmp& NIA COMPRESSOR Circut12 OUTDOOR MOTOR Number. 1 N um bar. 1 Hmaepowar: 3.6 H orsepowar: 0.33 Phase: 3 M olor Speed(RPM): 1100 Rated Load Amp@: 13.T Phaa: 1 Locked Rotor Amps: 53.1 Full Load Amps: IA Locked RotorAmp& 4S POWER EXHAUST ACCESSORY PI FILTERS REFRIGERANT R) (Field Installed Paver E)Mmtst) Type R-410 Phase: NIA Typo: Throvrway Factory Charge Horsepower: NIA F~ad: Yee Ckcm fl 310 Motor Speed(RPM); NIA Number 2 Cirarlt iR MIA Full Load Ampa: MIA Recommended 2Vx35'xZ Locked Rota Amps: NAA NOTES: 1 Mmdmum(HACK)CtcuitBrmksraizhgisbrinalelMtbnsklheUngedSUdmony. 2.Reiigarerd charge is an approximate vats.For a mom precise value,ass unit nameplate and service irabudiona 3 Value don not include Power Exhaust Accessory 4 Va4s includes oversizedmoWr 5.Value don not ntlrde PowerExhatW Accessory B EE R is rated at AN RI conditions and In accordance vith DOE lest procedures. 2017.06.02T16:51:23 Page 5 at 11 Job Name:. Preparat By:. UM Tug:YSCPf8Ci3RMA21 �ianYty 1 CLEARANCE FROM TOP OF UNIT 77 CLEARANCE 36' CLEARANCE 48" SUPPLY RETURN DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS ELECTRIC, CLEARANCE ROOFOVEn RIG— UNIT OUTLINE — ` 44 Vr i 4 JIT 88 11 E PACKAGED GAS/ELECTRIC DOWNFLGW TYPICAL ROOF OPENING 2017-MO2716:51:23 Pogo 7 of 11 MANE" Job Name: PrepvM 8yy:. Unll Tag:YSCM-nao..ea. wanlay:1 General The units shall be convertible airflow. The operating range shall be between 115°F and O'F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 1150F and 400F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-41 OA, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHCO74F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8'/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7'/2 to 8�/2 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 2017-08-02T16:5123 rRAA i e Job Name: Pr pwrd Byy UnM Tag:VSC048G3FMA21 l]oaouly,1 (Gas/Electric Only). Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 100F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to 50OF before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). 2017-08-02T16:51:23 Page 11 of 11 0 v Go N Q Z+ O N1 m 0 a fO O J�` N r cc O m U N / N z cc E v oc acc M _ o c = m@ � � v y 3 0 0 Q • / O � > N U f6 i a a > ca N d y c Z N N �% t d U O a) U) .. co a N o v O (n ___—_--__ a L a OD } Z 3 O y Q - 0 00I 00 [� v .� ` ' z W�y cto > N LL ill� a > to z W 000 o CL n o a a o m > j o o coo a. <O Z E CO o 0 W L4L E Q. �aZ o 0 0 o Q =fo uo J 0 � o O m ,J a U J ° 0 Y N ro � - m �WW Z?m 6 1' CL Ci N c Z E - F-i F- - ) m 'L c \ 0 cat 22 (D .r U O \ \ 0 0 s L p O \\ a m C 3 cc AD fa \ p N d /.. ) c O wi--� o ca a Q W J 7 �r ® �p1h_, , c c C N9 m // l0 E O o L $ L L e xs Q o u) V N m / E ;n E 0 ReceivedCol o o - c co w a i° O C T 4 6 Z017 Co Ira O m C U IT M 5 p�L IY.53 Map c m o ` 04 oci o N U m 6 10 sj �g �Ec 10 Env Iasi u�aN o Y C 3 8 ` 3 v V 9 m pi 1] Q' m 0 m o oas.0 3:00L3'9 '^wac.5 L C"I U C ? 0. aac,N„ a•-gym mCa ` O N O N N Ua VI_ulmu! 0ac$¢ o U 5 N a �wc`mU5 ao9 3°� 3 Fw macQ.)'�Qa � •c XOr- � Li o Q Ou oa w a CL m drtau c .m wo : OE W v '� a L D L m p Z < m o J a CU o a m [r E v _U Tf6 Q U E -> •L' I (D N Q v ii o w ° o C C C N O C O N E p m E 3 N V a) U m C C N n > fA _m C N M _ j C C O W �' E m O y O J Z "0 m U 3 O N N ri d o w a U o a V m v CD 0 O O Cl) = N L C O Z m O D cf0i c 3 w } = o_ co o N _ E o Q m u� U to m ° o a0o 0 v c? U Z m 3 I M c O O p O CGo U Z O a 3 a Z C c o c U) U w co n vi 0 - C c o u, U 2 I �-' a� m w Q o � fl. � N K E ' > a U w � 2 VJ U o 6 > IV o Q E 0 o N c 0 m U N 7 w ` O E m m 5 U g 3 ar o 'm m E w = o a o m m ' m N L o c w -a O Q w E m N o m o u, E 7 N m O m m .y O1 O al O Cn m C L m m y m ro o .20 E m m Q a c m �I OD C N O N m C co co O CD c v E U o m 0 m •� C N m U V- 6 a) = m Ql N y L 7 m a w m U m rn E co m Q N a c m o U m L C N m O N E E o Q c E 2 _� M L w w m T U E O V m U m C .tm• t (A O O V' N C140 0 '� C m C (D O E o w O CL OD U N m N m N f01 l •E .0 m Q Mp OC j d U) N �NO/ W m a) m C7 m (D U co C 7 O m E N +� Z O C O Q N v w O a N O 0 (D O` C N O .J a) m L O M LJJ _C m 0 E U Lo �° .3 2 c 3 �? f0 N U w U ° s o 0 m m J m N N tD N a) `� m O L m > y E N E C m U m -O iwt+ 3 Gf 0 oE2 o E J N m � o 3c -0 aN cL) n aa) 0 c � cw u rn ° m Q c NQ c E o c> w O 0 ° v; o � o Lo m � ( v m ur 7 .N pp � lL O Q1 C C C '2 7 m C , N m � U m W C O N 0 : N U X C O L L C N w .Q Q m O0 -C m 3 N Z ~ N m y� U) a U : ( U > N ° 9 ; rn M C ) C L 1 10 Q d W E Q O 3 C7 of 0- J C M c CO O p y wl C U) W t o O C V r N M 7 . . . . . a 7 U N m U) I w U m C CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 Go PHONE; (360)403-3551 BUILDING PERMIT Address:3617 172nd Street NE Permit#:1673 Parcel M 31052100302700 Valuation:18000.00 OWNER APPLICANT CONTRACTOR Name:Rainydaze Properties,LLC Name:Foss Heating and Cooling Name:Foss Heating and Cooling,Inc Address:P.O.Box 29408 Address:PO Box 29408 Address:333 E Blackburn Road City,State Zip:Bellingham,WA 98228 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone:206-914-8888 Phone:206-914-8888 Phone:360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Foss Heating and Cooling,Inc Name: Address:333 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: I CONST,TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL 1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. SALES TAX NO31C8:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 00, Abmkm IItNS 'h4ho 7/?//7 Signature Print Name Date Released By D CONDITIONS Adhere to approved appliance. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1019/2017 Mechanical Plan Review Fee $250.00 Total Due: $250.00 Total Payment: $0.00 Balance Due: $250.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon - ' CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address:3617 172nd Street NE Permit#:1673 Parcel#:31052100302700 Valuation: 18000.00 OWNER APPLICANT CONTRACTOR Name:Rainydaze Properties,LLC Name:Foss Heating and Cooling Name:Foss Heating and Cooling,Inc Address:P.O.Box 29408 Address:PO Box 29408 Address:333 E Blackburn Road City,State Zip:Bellingham,WA 98228 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone:206-914-8888 Phone:206-914-8888 Phone:360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Foss Heating and Cooling,Inc Name: Address:333 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By D e CONDITIONS Adhere to approved appliance. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/9/2017 Mechanical Plan Review Fee $250.00 Total Due: $250.00 Total Payment: $0.00 Balance Due: $250.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3617 172nd Street NE Permit#:1673 Purcel#:31052100302700 Valuation:19000.00 OWNER APPLICANT CONTRACTOR Name:Rainydaze Properties,LLC Name:Foss Heating and Cooling Name:Foss Heating and Cooling,Inc Address:PO.Box 29408 Address:PO Box 29408 Address:333 F,Blackburn Road City,State Zip:Bellingham,WA 99228 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone:206-914-8888 Phone:206-914-8888 Phone:360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Foss Heating and Cooling,Inc Name: Address:333 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: L1C#: EXP: LIC#: F.XP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNTTS: 0 OCC GROUP: BUILDINGS: l OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY: NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE..AND RCW 18,27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE.UNTIL A FINAL INSPECTION HAS SEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBCI IOIIRCI l0. SALES TAX NUTICX:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington 03101, Signature Print Name Datc Released By DA CONDITIONS Adhere to approved appliance. THIS PERMIT AUTI IORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIV.KfF PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 1019/2017 Mechanical Plan Review Fee $250 00 Total Due: $250.00 Total Payment: $0.00 Balance Due: $250.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon - CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3617 172nd Street NE Permit#:1673 Parcel#:31052100302700 Valuation: 18000.00 OWNER APPLICANT CONTRACTOR Name:Rainydaze Properties,LLC Name:Foss Heating and Cooling Name:Foss Heating and Cooling,Inc Address:P.O.Box 29408 Address:PO Box 29408 Address:333 E Blackburn Road City,State Zip:Bellingham,WA 98228 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone:206-914-8888 Phone:206-914-8888 Phone:360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Foss Heating and Cooling,Inc Name: Address:333 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By D e CONDITIONS Adhere to approved appliance. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/9/2017 Mechanical Plan Review Fee $250.00 Total Due: $250.00 Total Payment: $0.00 Balance Due: $250.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Job PJame: T WE" -1,1.11-BY: v8(A38G3EMA00 1 Trane Precedent Gas/Electric Packaged Rooftop Unit Overview , . ,,,,,,,r,,,,0,,,,, r,,,,,,, Application Unit Site°l EER IEER/SEER DX cooling, 3 Ton(036) Airflow static Height Widt sng L �tinlmUm Maximum 12 0 EER ta.tX1 gas heat Pressure 1200 cIm 0,200 in H2O 3.41 it 3.69 It 5.82 it 472.0 lb 339 kg Unit Features Fresh Air Selscticn Without fresh air selection Su;)plyFan/Drive/MotoiType Standard drive motor Panels/Pllters Standard condenser coil Unit Electrical Voh,igelphese%ti��208.230/6013 MCW 19.90 A I� MOP 30.00 A Controls Unit Controls Electro mechanical controls 3ph - Communications Option Without communications ;;,y.,; '��� ^��•'---^!^� System Monitoring Controls,1 Without system monitoring controls System Monitoring Contf$Nalt No monitoring controls Entering Dry Bulb 80.00 F Capaetly Entering Wet Bulb 67-00 F Gross Total 37.01 MBh Ambient Temp 95.00 F Gross Sensible 29.82 MBh Leaving Coll Dry Bulb 57 21 F Not Total 36.37 MBh Leaving Coll Wet Bulb 57.21 F Net Sensible 29 19 MBh Leaving Unit Dry Bulb 58.69 F Fan Motor Heat 0.63 MBh Leaving Unit Wet Bulb 57 78 F Refrig Charge-circuit 1 2.9 lb � Refr*ratlon System Options 1 Leaving Dew Point 5721 F Heating Section Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 65.60 MBh utpIA ttoating Capacity with Fan 66.47 M8h Heating EAT 70.00 F Heating LAT 120.80 F Heating Temp Rise 50.80 F CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED Received DATE BY S E P 2 7 2017 NO CHANGES AUTHORIZED UNLESS APPROVED:BY THE BUILDING INSPECTOR 2017.09-08 22:00:31 Z Page 1 0l 10 ob Name: Pny>mca B J yy Und Trig-YSG03BG3EMA00 Ouanury 1 Fan Section Type FC Centrifugal Type PrWoliar rive Type Direct ' i Fan Quantity rr fF Drive Type Dfrec.i W Airflow 1200 elm r Fan Performance —beslgn ESP 0,200 in H2O denser Fan FLA 110 A Indoor Motor Operating Power 0.26 Dhp Exhaust Fan-00 _ �. Indoor Motor Power 0.19 kW Type FC Centrifugal Indoor RPM 769 rpm Onve Type Direct Indoor Fan FLA 1.10 A Exhaust Fan P Exhaust Fan FLA 5.70 A Compressor Sect Power 0,00 kW - - - liVi It 1 RLA 12.80 A " Circuit 2 RLA 0.00 A A .y)f Page 2 of 10 2017-09.08 22:00:31 Z ProWlred 8yy:. lH+fl Teq:VSC03B63EMA00 9umtlry:1 TOP PANEL CONDENSER FAN EVAPORMOR SECTION ACCESS PANEL CONDENSATE DRAIN(ALT) 314%14 NPT DIA HOLE —.\ ONpENSER COIL 4114, 23 9?1 B' `\ UNIT CONTROL WIRE 7fB'DIA HOLE 42114• SERVICE GAUGE PORTACCESS 13*rDIA HOLE \ NIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE 112"NPT OAS CONNECTION CONDENSATE n 1rr--{ 4 liB• NOTES: 1.TH RU-THE-BASE OAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION I I I I I I I RETURN I 24' SUPPLY I I I 15 I/T 91f4' 14' 39SN' PLAN MEW UNIT DIMENSION DRAWING 40 7B• RETURN 23114' HORIZONTAL SUPPLY It Yt' I AIRFLOW 20114' IL 9 518' S SIB' iyl t3q" 1T 114' 8718'L13 tic 311 B' 41H' 9718' 59f 18' CONDENSRE 7W 14 114" PACKAGED GAS!ELECTRICAL DIMENSION DRAWING 2017.09.08 22:00:31 Z Pape 3 of 10 Job Name:. Pireipit"(1 BY; Unit Tag Y9(:038O3EMA00 Ovantityy 1 i SUPPLY 7F Tu4N 31'r-14 NPT DRAIN CONNECTION 239016 �avc ISOMETRICPACKAGED COOLING Page 4 of 10 2017-09-08 22:00:31 Z TRANEe Job Name: Prn(Mr Byy:. Un11 rag, :YSC036(i3EMA00 quantity 1 ELECTRICAL/GENERAL DATA 'GENERAL M(4)M HEATING PERF(>PMANCE Model: YSC03BG Oversized Motor HEATING-GENERALOATA Uatl Operating Voltage: 187-253 M CA NIA H eating Mom: M adlum U nil P On ary Voltage: 205 MFS: NIA H eating Input(BTUy. 00,000 Unit Secondary Voltage 230 MCB: NIA H eating 0utpui(BTU)-. 65,600 Unit H eriz: 00 Unit Phase: 3 No Bsnem: 2 No.Stages 1 EERMEER 1201140 Standard Motor Field insisted Oversized M utor GaslMet Pressuro MCA 19,9 MCA NIA NatumlGas(MinfAk): 4,6114.0 MFS: 30.0 MFS: NIA LP(M InIMuQ 1101140 MCB: 300 MCB: MIA Gas Pipe Connecllon Size: 1l7 INDOOR MOTOR Standard Motor Ovsrsood Motor Field Installed Oversized Motor Number. 1 Number. NIA Number: NIA Horsepower 0.75 Horsepower. NIA Homepower NIA Mohhr Speed(RPM): - Motor Speed(RPM) NIA Motor Speed(RPM)t NIA Phase 1 Phase MIA Phase NIA FWILosdAmpa: 5.7 Full Load Amps NIA FWILoadAmps NIA LockedRotorAmps — Looted RoWrAmps NIA Looked RolorAmpw NIA COMPRESSOR CircuR W OUTDOOR MOTOR Number. 1 Numbar. 1 Horsepower: 2.8 Horsepower: 025 Phase: 3 M clor Speed(RPM): 1100 Rated LoedAmps: 123 Phase: 3 Locked Rotor Amps: 95.0 Full Losd Am pa: 1.1 Locked RotorAmps 3,6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT �) (Field Installed Power Exhaust) Type R-410 Phase: NIA Type: Throwavey Feciory Charge Horsepower. NIA Furnished: Yen Motor Speed(R PM): MIA Number 2 Ctadt it 3.2b Full Load Amps: NIA Recommended 20'x75'7¢' CkcWtIP2 MIA Locked Rotor Amps: WA NOTES: 1 M andmum(HACR)Circuit Broaker sizing is lor Installations In the United Stales only. 2 Retigarent charge in an approximate value Fora mom precise value,ace whit nameplate and service instructions 3 Value does not include Power Exhaust AccesSory 4.Value Includes oversized motor. 5.Value does not Include Power Exhaust Accessory. B.EER is mind at AN RI conditions and in acmrdenme Wth 00E lest procedures 2017.09.08 22:00:31 Z Page 5 of 10 w r Jub Name: (Mitt Tay:Y C038G3EMA00 Ouantiry't INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER 4�1 MANUAL OUTSIDE AIR DAMPER /'� BAROMETRIC RELIEF \ OARSIZED MOTOR BELTDRIVE MOTOR POWE R EXHAUST O THROUGHT THE BASE ELE CTRICAl.C3A5(Fl0 PS) UNIT MOUNTED CIRCUIT BREAKER(FIOPS) UNIT MOUNTED OISCONNECT(FIOP5) POWERED CONVENIENCE OUTLET(FIOPS) I� ` HINGED 000R5(FIOPS) �'(✓) HAILOUARD CJ SMOKE DETECTOR,SUPPLY!RETURN �- PACKAGED GAS 1 ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAI EXCHANGER EHEAT IF ROOF ROOF C f,URB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET A 193.0111 © 450b iE)LEN6H7 (F)WIDTH 57T O Ib 572 01b 178 0 Ib SS 0 b 33' II 9- OTE l I At welghtsare epprowmale, 2 Weights for options that are not Ibt refer to Installation guide 3. The actual warghl are IMad on the unit namapONs a. Refer to unit nameouile and installation guide In eerghts before scheduling transportation and installation oluML S The weight shoym repraxMe the typical unit operating weight for the configuration seceded Estimated at I-10%ofthe nameplate weighl 8. \wiry weight,connection,and all dimension with installer documents before instalNlfon 7 Corner werghts are Tvan for Inbnnat0o onry. B NaU5lupping watght of eptroeel acrsasortes should be added to unit weight when ordering lictory or hid installed accasaotwa f J a E > F J PACKAGED GAS/ELECTRICAL RIGGING AND CE NTE R OF GRAVITY Page 8 of 10 2017.09-08 22:00:31 Z Job Name:. �_c RAfE.* Pronted Dy rA --� �w �� Umtp Txg VSC036G3EMA00 ouanuty I CLEARANCE FROM TOP Of UNIT 72" CLEARANCE 36" CLEARANCE 48" SUPPLY RETURN DOWNFLOW CLEARANCE36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING----, �^ 1` 1 UNfT OO TUNE `�I1 I 37" 44 V I I I 40" 68 3A1(r PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING 2017.09.08 22:00:31Z Pepe 7 of 10 0 •i0 Plame P019A,W By:. f7FY1•i fall lag:ISC036G3EMAW ]unn4ryr General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be culored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seailIs exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC 1 02F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8%2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71/2 to 81/2 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 2017-09-08 22:00:31 Z Page 8 of 10 JPorb NaremgdeY8: : 0 UMWE' c. 038G3EMA00 Ouanfily:1 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8-5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions 2017.09-08 22:00:31 Z Page 9 01 10 Job Name: 0 rm4wPrepano0 By'. Unit Tup.Y C036G3EMAW quan9;1 (Gas/Electric Only). 2017-09-08 22:00:31 Z Page 10 of to OD Go § % m ° m 5 1- \ § o 2 o (D - ) 22 \ k (D C� Cc o / \ � � � ` k / § \ / , .< Cu � � _ - 2 _ / \ \ > � ■ � y U)cn § a . - cn § _ f a 7 U) 0 2 ' a I Q�_ @ ka G _ iCn / \ LU (D � / ( N @ ■ _ � co � § ] V k » � � / � } S � 75 , z iT) � Z WmV \ 4 N / � loz 0 § O k m , a) ■ \ � © ` \ z ■� \ 0 m $ & y ,5 0 ��� - � � O ; oa � 5 \ \ Co Cc § co \ �J© \ t 2yr � # q 3 2 § E ` 4b § � 5 « = S ' - - - 2 d 3 ) e S » � 2 \ S . © 0 o 0 k 2 k ® \ � ® Q - - d � f IL - \ 3 0 # k � 0 § . ■ § � � g / 2 , 2 t4 0 � % \ » § - � , E d � ! Cn CL/ k � ME cn ) / 2 E Received _ # oo ƒ � , .0 § u 6 m [ƒ 0 § /U�/ Co 7 w / - �bi- �% .� O 1 .. � � .� � '� .i. .i � } � O ;.� .� � � � � "� � � ! ��' t � }} � 1 . . � - 4. 0 O OD t m m c O y .� O p) �� Cg w 0 04 Ev v M m aapp E�vd ° 9waJ A O Q m N0 2>1 m u0i L Y R & m _ o i°tS� Qy E N� �' aII N m u«ZdN aye a Xn � . m N a a) aNy �V co �q° 3�aV'nym c F U LL c O C CL ow 'Q.@a vwo�aL cQc� o '� .0 C m Q m `-'w� dLcm ° ufo�mcmom o ai 7 r a m a u o rc r K«a n .D CM z W o L m U c Q a 3 a) c � a 'a o U aryO > U cQ a) Q) m 'E 2 U) M U C � m w o O Q o W -0 o E m O C UI 0 N E E m N E 31 C .LD > a� a m o o W Z, " o = E 0 O z "O ca a) : U w N (Dm o o L ti N N m m fn o U) V N o v o N — C? m = ro U O Z o c 3 ao } a — Cl- �° o N _ EE a) ° o O _� U N U U) m a) L di ml C m ri z m 3 n) c _Q V _C h] W a) C m 0 Obi co 0 p) � O U z U m aZ C U o N O o _ ri a vi .` 'V N � C O rn U O Y ' yr m a) cn U) (� w L C § U n a O C V v a) 3 O = fn E O2 a E M O' N �1 fn C a (� N O N O) 'lp m m m N 7 U U 3 N •U m m T L w N O' N a O a) V) C L Q N C 0 N U O Q j j m O O c is —88 m E C O 12 0) O) -O d 0) O m O 0) Q E co a) - "S tE Ol a OI Y o c a 3 -0 c m m in a N C •C CV Q N C y p C fn N a o E U ° _m m U) in O N m U m a) m ° . C a w U v cm E Q H a pa) U m n ac o Q V ++ O N m 7 a 0 w C E 2 U) c7 N LL m >, M E 0 N O 0 fn M, a) L.. a (A O O O n a) 2 E C O O L TQ U N O U E N '� m a) ¢ O� O N = 0)N w C N II C O co C O V) 2' O E L fn N •Q .Q W m = N U E O 'C a) .0C v C N N a) E ? (a < N C O O_ 7 y0 Q C E Q O v O m tG rn _0) N O V Q p c 0 U a) L O C C O L U m (L) a) a E U (n '° v '� ? c: c N M '(� U W ri U E a) a) m m a m (0 0 Q m N_ N D 0 N T 7 .. m 0 U N al C J O a O L )a N _ E N o c a) U m U •� 3 Q d n c +•� 30 wo c E W Q Mo o c N a Q _ a J E Eaj W N N C N m V0) � O a) C C f`D U 0 E m m aNi E o o .,� m ++ Q G■S�. I— m fn m No 0 0 V N NO O W O U n m mWC 0 .O > mL ` oOCC N zW 3 m N 0 2 -0Q L C vUD _ DUu) Q > 7c3 Cl)m U) � a owo) E ~ ca E a � O O O ON ) R L _ O C U N ci LL ~ m Cn W (n m .0U C -Aok Job Name: .��//,�' Prepared By:. Unit Tag:YSC048G3RMA21 Quantity:1 Trane Precedent Gas/Electric Packaged Rooftop Unit rrrrrfrr rOrrOrrttrOlrirrf Application Unit Size Supply Fan External Dimensions(In.) Weight EER [EER/SEER External IX cooling, 4 Ton(048) Airflow Static Pr Height Width Length Minimum Maximum 12 0 EER 14.00 gas heat sure 1600 cfm 0.500 in H2O 3.41 ft 3.69 ft 5.82 ft 492.0 lb 348 kg Unit Features IL Fresh Air Selection Low Leak Econ-dry bulb 0- 100%ibar rel 3p Suppl fan/D Type Standard drive motor Y - Panels/Filters Standard condenser coil Unit Electric Voltage/phaselherb 208-230/60/3 ' MCA 25.40 A MOP 35.00 A Controls, Unit Controls Microprocessor controls 3ph Communications Option Without communications System Monitoring Controls 1 Without system monitoring controls System Monitoring Controls 2 No monitoring controls •e Entering Dry Bulb 80.00 F Capacity Entering Wet Bulb 67.00 F Gross Total 48.90 MBh Ambient Temp 95.00 F Gross Sensible 38.78 MBh Leaving Coll Dry Bulb 56.90 F Net Total 47.41 MBh Leaving Coil Wet Bulb 56.90 F Net Sensible 37.29 MBh Leaving Unit Dry Bulb 58.78 F Fan Motor Heat 1.49 MBh Leaving Unit Wet Bulb 57.63 F Refrig Charge-circuit 1 3.1 lb Refrigeration System Options Leaving Dew Point 56.91 F Neat Type Gas Heat Heating Stages 1 Output Heating Capacity 65.60 MBh Output Heating Capacity with Fan 67.50 MBh Heating EAT 70.00 F Heating LAT 108.20 F Heating Temp Rise 38.20 F CITY OF ARLINGTON Received BUILDING DEPARTMENT APP OVED 11 OCT 0 6 2017 eon-00-02T18:51:23 DATE 0 � 'Page 1 of NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR 140T0 VL 'I'IAIf Y'Tri TrUVTWOO OWCUUB Q3VQ*9tiqA ��i]IAg11')AN 5HTYG afil4>-iwA-"I NV Alk T Job Name: Prepared By: v XWE Unit Tag:YSC048G3RMA21 Quantity:1 Indoor Fan Data _ _. Outdoor Fan Data Type FC Centrifugal Type Propeller Drive Type Direct Fan Quantity 1 Indoor Fan Performance Drive Type Direct Airflow 1600 cfm Outdoor Fan Performance Oesign ESP 0.500 in H2O Condenser Fan FLA 1.40 A Indoor Motor Operating Power 0.61 bhp Exhaust Fan Data Indoor Motor Power 0.45 kW Type FC Centrifugal Indoor RPM 1028 rpm Drive Type Direct Indoor Fan FLA 1.40 A Exhaust Fan Performance Exhaust Fan FLA 6.90 A Power 0.00 kW Circuit 1 RIA 13.70 A Circuit 2 RIA 0.00 A jj > Compressor park None Parts Is"a�otfliprossbilrwarref None 2017-08-02T16:51:23 Page 2 or 11 I Job Name:. 0 Prepared By:. Unit Tag:YSCO48G3RMA21 Quantity:1 SOP PANEL EVAPORATOR CONDENSER FAN SECTION ACCESS PANEL CONDENSATE DRAIN(ALT) 314"-14 NPT DIA HOLE ,—COHO EN SE R COIL 4 114" 23 9116" NIT CONTROL WIRE 7/8"DIA.HOLE 42114" SERVICE GAUGE PORTACCESS 1 318"DIA.HOLE NIT POWER WIRE C 0NTRO LAND CO M P RE SSO R ACC ESS PANEL THROUGH THE BASE 1/2'NPT GAS CONNECTION CONDENSATE --N 23 1R'� 43116' NOTES: 1.THRU-THE-BASE GASAND ELECTRICALIS NOT STANDARD ON ALL UNITS. 2.VERIFYWEIGHT,CONNECTION,ANOALLDIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION r---- I 1 1 1 I 1 RETURII I 24' SUPPLY I 18 I I I l I I — — I_4• I51!L' 91A" IV 1+3518- PLAN VIEW UNIT DIIJENSION DRAWING RETU RII 40 7/8' 231/4" HORIZONTAL SUPPLY 14 V4- AIR FLOW 20 1/4' 9 S/8 4 314" 5 S/8" 171M" 8718" 131/t" 33/16" 4114" 89 778' S 9/16 CONDENSATE 75l$- 44 114" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING 2017-08-O2T1B:51:23 Page 3 of 11 . MW Job Name:. Prepared By:. Unit Tag:YSC048G3RMA21 Quantity:1 SUPPLY RETURII 3/4"-14 NPT DRAIN CONNECTION 23 g111- \4\1W r ISOMETRIC-PACKAGED COOLING 2017-08-02T16:51:23 Page 4 o111 Job Name:. • YS Prepared C rowr UnitTag:YSC048G3RMA21 Quantity:1 ELECTRICAL/GENERAL DATA GENERAL(2)(4XM HEATING PERFORMANCE Model: YSC048G Oversized Mator HEATING-GENERAL DATA Unit Operating Voltage: 187-253 MCA: N/A Heating Model: IA edium Unit Prim ary Voltage: 208 MFS: NIA U nit Secondary Voltage 230 MCB: N/A Heating Heatng Input (BTU): 65,600 U nit H ertz: 60 U nit P ha se: 3 No Burners: 2 N D.Stages 1 E E R!S E E R 12 0lM.0 Standard Motor Field Installed Oversized M utor G as Inlet Pressure MCA 25.4 MCA N/A N atu ra l G as(M i NM'a): 4.5114.0 MFS: 350 MFS: N1A LP(M WMax) II_W14.0 MCB: 35.0 MCB: N/A Gas Pipe Connection Size: 112" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number. I Number: N/A Number: N/A Horsepower 1 0 Horsepower. NIA Horsepower: NIA Motor Speed(RPM): _ Motor Speed(RPMy NIA Motor Speed(RPMk N/A Phase 1 Phase NIA Phase N/A F ull Lo ad Am ps 69 Full Load Amps: N/A Full Load Amps: NIA Locked RotorAmps: _ Locked RotorAmps: N)A Locked RotorAmps N/A COMPRESSOR Circuit 1)2 OUTDOORMOTOR Number: 1 N um bar: 1 Horsepower: 3.6 H orsepo wer: 0,33 Phase: 3 Motor Speed(RPM): 1100 Rated LoadAmps: 137 Phase: 1 Locked Rotor Amps: 63-1 Full Load Amps: 1 4 Locked RotorAmps: 46 POWER D(HAUSTACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower NIA Furnished Yes Factory Charge Motor Speed(R PM): N/A Number 2 Circuit#1 311r Full Load Amps: NIA Recommended 20'k35"AT Circuit#2 N/A Locked RotorAmps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2 R etrigerant charge is an approximate value For a make precise value,see unit nameplate and service instructions 3 Value does notincude Power Exhaust Accessory. 4 Value includes oversized motor 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AH RI conditions and in accordance with D 0 E test procedures. 2017-06-02T16:51:23 Page 5 of 11 i r L Job Name:. itmPrepared By:. Unit Tag:YSC048G3RMA21 Quantity:1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER I--68016 Id ED OUTSIDE AIR DAMPER I I i) MANUAL AtIUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF 0 OVERSIZED MOTOR BELT DRIVE 140TOR O POWER EXHAUST TH RO UGH7 TH E BASE E LE CTRICAL/GAS fFIOPSj / UNIT MOUNTED CIRCUIT BREAKER(FIOPS) UNIT MOU NTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) HINGED DOORS(FIOPS) 1� O HAIL GUARD SMOKE DETECTOR,SUPPLY/RETUR14 PACKAGED GAS ELECTRICAL NOVARCONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNITWEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING 11 NET O 205.0 Ib V 46.0 Ib (E)LENGHT (Fl WID7H 598.0 Ib 492.0Ib 183.0 lb LD, 58.o Ib 33" OTE: 1. Al weights are apprommate 2 Weights foroptions that arenotlist ieferto Installation guide 3 The actual weight are listed onthe unit nameplate 4. Refarto unitnameplate and installation guide forweights before scheduling transportation and installation ofunit 5. The weight shown represents the typical unit operating weight forthe configuration selected Estimated at+J-10%ofthenameplate weight. 6. Verify might,connection,and all dimension with installer do cum ents before installation. 7. Corner weights are given forinfonnation only. 8. N eUShipping might of optional accessories should be added to unit weight when ordering factory or field installed accessories. F J PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY 2017-08-02T16:51:23 Page 6 of 11 c Job Name:. • MWi Prepared YSC Unit Tag:YSC04HG3RMA21 Quantity:1 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" SUPPLY RETURN DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPEMIIICf I I UNIT OUTLINE �VIII I 37" I 44 yr 1 1 I 40" 68 3116' PACKAGED GAS/ELECTRIC OOWNFLOW TYPICAL ROOF OPENING 2017-00-02T16:51:23 Page 7 of 11 i r � Joe Name:. Prepared Unit Tag:YSC048G3RMA21 Quantity:1 Q \ e CONOMIZERHOOD BAROMETRIC RELIEF HOOD CONOMIZER HOOD 29" o �'f �JG� l np 5 314" 19" LOW LEAK ECONOMIZER HOOD ACCESSORY 2017-08-02T18:51:23 Page 8 of 11 Jim Job Name:Pnea , • MANE Unit Tag:YSC048G3RMA21 Quantity:1 General The units shall be convertible airflow. The operating range shall be between 1150F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 1150F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8% ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71/2 to 81/z (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 2017-08-02T18:51:23 Page 9 of 11 I Jab Name- 1 TRANE UnitPared Tag:YSC048G3RMA21 Quantity:1 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminumn coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions 2017-0&02T16:51:23 Page 10 of 11 AM Job Name:. Prepared By:. TRANE Unit Tag:YSC046G3RMA21 Quantity:1 (Gas/Electric Only). Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50OF before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to 50OF before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). 2017-08-02T16:51:23 Page 11 or 11 Permit Information Date 9/28/2017 Permit Number 1673 Project Name Zoet Family Restaurants,LLC Applicant Name Foss Heating and Cooling Applicant Address PO Box 29408 City,State,Zip Mount Vernon,WA 98273 Contact Abrahm Rollins Phone 206-914-8888 Email orders@fossheating.com Permit Type Commercial Mechanical Site Address 3617 172nd Street NE Valuation 18000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Replace two RTU Assigned To Kristin Foster Property Parcel Address Legal Owner Owner Phone Zoning 31052100302700 3617 172ND ST NE Rainydaze Properties,LLC 206-914-8888 599 Other Retail Trade NEC Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type Foss Heating and Cooling, 360-336- orders@fossheating.comCONTRACTOR I-abor& FOSSHCI9858 Inc 1517 Industries Review Date Type Description I Target Date Completed Date I Assigned To Status 9/28/2017 110ornmercial Mechanical 10/5/2017 lKevin Olander 111n Review Fees Fee Descri lion Notes Amount Mechanical Plan Review Feel 322.10.00.001 $250.0 Totall $250.0 Uploaded Rea { Upload File Date File Uploaded B 9/28/2017 3:23:51 PM Packaged Unit 1 Specifications.pdf Foster,Kristin }( 9/28/2017 3:23:51 PM Packaged Unit 2 Specifications.pdf Foster,Kristin x 9/28/2017 3:21:26 PM 1673 Application.pdf Foster,Kristin x 9 COMMERCIAL MECHANICAL • PERMIT APPLICATION CIN;DO Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: New Installation Q Replacement Alteration Project Address: 3617 172nd St NE Parcel#: 2697825 Replace RoofTop Heating Units Project Description: Valuation:$18,000 owner.ZOET FAMILY RESTAURANTS LLC Phone#:206-914-8888 Address: 16221 178TH PL NE City:Woodinville State.WA Zip:98072 Email Address: ORDERS@FOSSHEATING.COM ainy aze Properties LLL 206-914-8888 Contact Person: Phone#: Address:PO Box 29408 City:Bellingham State: WA Zip: 98228 Email Address:ORDERS@FOSSHEA-nNG.COM Contractor Name.Foss Heating and Cooling Phone#: 360-336-1517 Contractor Address:333 E Blackburn Rd, Ste A City:Mount Vernon State:WA Zip:98273 Email:orders@fossheating.com Abrahm Rollins Contact Person: Contractor License Number: FOSSHC19858A Expiration: 11/1/2018 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT 2 UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will bp in laws rules and regulation of the State of Washington. (ificro/i.r r%v�,r✓.,if�'lllnt�� Applicants Signature: »- - •��� Date 09/25/2017 Applicants Printed Name: Abrahm Joseph Rollins FOR STAFF USE ONLY eCel vec S ,�2.5 UP Permit# Accepted By Amount Received Receipt# Datt`R—ecdivdd`—" 6/16LP Page t of 1 2015 Washington Stan. ,iergy Code Compliance Forms for Commercial,R2 /R3 over 3 stories and all R1 Mechanical Summary MECH-SUIO 2015 Washington State Energy Code Corr pliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R 1 Revised January 2017 Project Information Project Title: 1-This title will copy onto other fors Date L,r'/7 �OS5 Applicant Information. Provide contact information for individual who can respond to For Buildi Dept.Use inquiries about compliance form information provided. /v /�/1 Cry r Company Name: "A - f4 6fr7 J N� Company Address: J�.f 4J �Oi/ ��p� /fill n�r Applicant Name: m ! el !�^' /U/��✓��� Applicant Phone: -&-e- Project Description New Building ❑Building Addidon ❑Tenant Improvement ❑system Retrofit JXNo System Changes Briefly describe mechanical systems in the text bar provided ❑Total Bldg Performance(TEP) 'e/�� C/ // ✓ '�� // �'QJC, "��` �� This path includes all mandatory k-"114 i LAC •,N provisions per C401.2 Option 2. MECH-SUM,MECH-CHK,and C407 Energy Analysis forms required. ❑ Load calculation summary ❑ MECH-LOAD-CALC Form Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating,cooling or ventilating needs.If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. X Mechanical Plans ❑ MECH-EQ Forms(TBD) Mechanical Schedules Indicate location of equipment compliance information.If provided on plans then MECH-EQ forms are not required, however,include on plans all applicable compliance information listed in MECH-EQ tables, ❑ DOAS is required per C403.6 effective July 1,2017(office,retail,education,library and fire station occupancies) All occupied,conditioned areas shall be served by a DOA S that delivers required ventilation air in a manner that does not require space conditioning fan operation.Space conditioning fans cycled off when no heating or cooling is required. Dedicated Outdoor Air ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS(C403.6,Exception 1) System Requirements and ❑ Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS(C403 6,Exception 2) High Efficiency VAV IS DOAS included in project,although not required(occupancy not office,retail,education,library or fire station) Alternate ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40%per C402.4.1.4 with 100%of conditioned floor area in building served by DOAS ❑ Exception to air economizer per C403.3 Exception 1,include MECH-ECONO form. ❑ Project includes HVAC air distribution systems that provide heating and/or cooling If yes,provide a MECH-FANSYS-SUM form. Fan Power ❑ For one or more systems,the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes,provide a separate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2 11 and MECH-FANSYS-DOC for requirements and exceptions. ❑HVAC Hydronic Systems Hydronic chilled water El water-loopheat pump No hydronic systems ❑ Hydronic heating water ❑ Geothermal ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90%of heating and cooling capacity to be equipment listed in tables C403.2 3(1)-(9)or air-to-water heat pumps and heat recovery chillers.All equipment listed in tables C403 2.3(1)-(7)must be 15%more efficient than minimum requirements All stand alone supply,return,and exhaust fans over 1 hp must have FEQ 2 71 and must be C406 Additional Efficiency selected within 10%of maximum total or static pressure, ❑ C406.6 Dedicated outdoor air system(DOAS) Options-Mechanical Requires 90%of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90%of floor area be in occupancy types listed in C406.7.I and that 60%of annual hot water energy use be provided by heat pump,waste heat recovery or solar water-heating systems. 2015 Washington S , Energy Code Compliance Forms for Commercial,i._and R3 over 3 stories and all R1 Mechanical Summary, • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Equipment Type(a) ❑ Hot water heating tank(s) ❑ Instantaneous [� No service water systems Service Water Heating El Dedicated boiler ❑ Heat exchange from space heat boiler or Systems central hot waterlsteam Distribution Type(s) ❑ Circulation System ❑ On-demand Commissioning Commissioning is required for. ❑ Mechanical systems per C408 2 ❑service water heating systems per C408 4 if required,commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: I�Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btulh cooling of 300.000 Btulh heating.Mechanical systems commissioning not required ❑ Capacity of largest service water heating system in building does not exceed 200,000 Btulh.Service water heating systems commissioning not required, Low Energy and Semi-Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity,Btulh Capacity,Bluth Capacity, Compliance Type Location in Plan(s) Spece(s)Served square feet (Note 4) (Note 5) Btulh-sf Check Notes Note 4-Provide total installed heating output capacity of systems serving Low Energy or Semi-Heated space(s)in btuh. Note 5-Provide total installed cooling capacity of system serving Low Energy space(s)in Btulh.Not allowed for semi-heated spaces.Enter 0 if no cooling Note 6-Refer to Section C402.1.1 Low Energy Building.Intalled peak space conditioning capacity,heating or cooling,may not exceed 3.4 Btu/h'sf. Note 7-Refer to Section C402.1 1 1 and Semi-Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Stulh"sf. Only systems without electric resistance heating and no cooling are eligible for the well insulation exception under semi-heated. Launa Peterson From: Launa Peterson Sent: Tuesday, October 03, 2017 4:40 PM To: 'Bill McGuinness' Cc: Kevin Olander Subject: 3617 172nd Street NE We are reviewing the Commercial Mechanical Application that was submitted on 9/28/2017.To further the review, we need information on the economizer. If you do not have information on the economizer, please reference the code section being applied. Thank you, Launa Peterson, CPT Permit Technician City of Arlington 18204 59th Avenue NE Arlington, WA 98223 (located inside the Airport Office Building) 360-403-3551 ced@arlingtonwa.gov 1 CITY OF ARLINGTON INSPECTION CARD No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: RAINYDAZE PROPERTIES CONTRACTOR: FOSS HEATING&COOLING, INC JOB ADDRESS: 3617 172ND STREET NE LOT NUMBER TYPE GROUP NATURE of WORK: REPLACE 2 RTU USE of BUILDING: RETAIL PERMIT No: BLD1673 DATE ISSUED: INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS FOOTING BUILDING FOUNDATION (360)403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) ROUGH PLUMBING GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATED WALLS) CEILING GRID STRUCTURALSLAB CROSS CONNECTION CONTROL IN PREMISE PUBLIC WORKS GRADING (360)403-3457 TEMPORARY TECSP ASBUILTS APPROVED MAINTENANCE BOND STORM DRAINAGE SYSTEM PAVING,SIGNAGE&MARKINGS LANDSCAPING PLANNING CONDITIONS ONSITE UTILITIES WATER ONSITE UTILITIES SEWER Sewer OFFSITE UTILITIES WATER (360)403-3508 OFFSITE UTILITIES SEWER SEWER PRETREATMENT Water CROSS CONNECTION CONTROL PREMISE (360)403-3526 SIDE SEWER/CLEANOUT/FINAL WATER SERVICE INSTALLATION WATER SERVICE FINAL FIRE DEPARTMENT (360)403-3526 HYDRO/FLUSH (360)403-3607 UNDERGROUND""INCL FDC (360)403-3607 FIRE ALARM /AUTOMATIC SPRINKLER (360)403-3417 HOOD SUPPRESSION SYSTEM (360)403-3607 FINAL FIRE WALK-THROUGH (360)403-3417 FINAL INSPECTION ALL SIGNATURE BLOCKS MUST BE COMPLETE Job Name:. Prepared By: TIIA E® Unit Tag:YSC048G3RMA21 4- Quantity:1 Trane Precedent Gas/Electric Packaged Rooftop Application Unit Size 111PP%Pumpmporyoramnmmm ernal Dimensions(in.) Weight EER IEER/SEER 9r External = DX cooling, 4 Ton 048 Airflow Static Height Width Length Minimum Maximum gas heat ) Pressure 12.0 EER 14.00 1600 cfm 0.500 in H2O 3.41 ft 3.69 ft 5.82 ft 492.0 lb 348 kg I Fresh Air Selection Low LeakEcon-dry bulb 0- 1 00/o/bar rel 3p ■ Suppl rive/Standard drive motor Motor MotorType - Panels/Filters Standard condenser coil Unit Electrical Voltage/phase/hertz 208-230/60/3 MCA 25.40 A MOP 35.00 A Controls .—a Unit Controls Microprocessor controls 3ph Communications Option Without communications System Monitoring Controls 1 Without system monitoring controls System Monitoring Controls 2 No monitoring controls Cooling Entering Dry Bulb 80.00 F Capacity Entering Wet Bulb 67.00 F Gross Total 48.90 MBh Ambient Temp 95.00 F Gross Sensible 38.78 MBh Leaving Coil Dry Bulb 56.90 F Net Total 47.41 MBh Leaving Coil Wet Bulb 56.90 F Net Sensible 37.29 MBh Leaving Unit Dry Bulb 58.78 F Fan Motor Heat 1.49 MBh Leaving Unit Wet Bulb 57.63 F Refrig Charge-circuit 1 3.1 lb Refrigeration System Options Leaving Dew Point 56.91 F Heating Section ___c EIRor Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 65.60 MBh Output Heating Capacity with Fan 67.50 MBh Heating EAT 70.00 F Heating LAT 108.20 F Heating Temp Rise 38.20 F 2017-08-02T16:51:23 Page 1 of11 Job Name:. Prepared By: TIIA E® Unit Tag:YSC048G3RMA21 Quantity:1 SectionFan 1WIndoor Fan Data Outdoor Fan Data Type FC Centrifugal Type Propeller Drive Type Direct Fan Quantity 1 Indoor Fan Performance Drive Type Direct Airflow 1600 cfm Outdoor Fan Performance Design ESP 0.500 in H2O Condenser Fan FLA 1.40 A Indoor Motor Operating Power 0.61 bhp Exhaust Fan Data Indoor Motor Power 0.45 kW Type FC Centrifugal Indoor RPM 1028 rpm Drive Type Direct Indoor Fan FLA 1.40 A Exhaust Fan Performance Exhaust Fan FLA 6.90 A Compressor Sect er 0.00 kW Circuit 1 RLA 13.70 A Circuit 2 RLA 0.00 A Compressor parts None W Parts less compressor warranty None 2017-08-02T16:51:23 Page 2 of 11 Job Name:. Prepared By: TIIA E® Unit Tag:YSC048G3RMA21 Quantity:1 TOP PANEL CONDENSER FAN EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN(ALT) 314'A4 NPT DVL HOLE CONDENSER COIL 4 1/4' 23 9/16" U NIT CONTROL WIRE 718'DIA.HOLE 421/4' SERVICE GAUGE PORTACCESS 1 3B'DIA.HOLE NIT POWER WIRE CONTROLAND COM PRESSOR ACCESS PANEL THROUGH THE BASE 1/2"NPT GAS CONNECTION CONDENSATE 23 12"� 4 3p16„ NOTES: 1.TH RU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. 'ERIFYWEIGHT,CONNECTION,AND ALLDIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION! r———— I I I I I I I I RETURN SUPPLY I I I 4" L15 12" 91/4' L 14" 1 L 5/8" PLAN VIEW UNIT DIMENSION DRAWING i 40 7/8" RETURN 231/4" HORIZO AJR FLOW SUPPLY 143/4' 20114" - O O �� 4 3/4' 5 5/8" 17 1/4" 8 7/8" 13 1/4' 3 3/16" 69 7/8" 5 9/16" CONDENSATE 75/8" 44 1/4" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING 2017-08-02T16:51:23 Page 3 of11 Job Name:. Prepared By: TllA E® Unit Tag:YSC048G3RMA21 Quantity:1 V A V SUPPLY RETURN 3f4"-14 NPT ®� DRAIN CONNECTION 23 9116' `4114" r ISOM ETRIC-PACKAGED COOLING 2017-08-02T16:51:23 Page 4 of11 T �® Job Name:. Prepared By:. Unit Tag:YSC048G3RMA21 Quantity:1 ELECTRICAL!GENERAL DATA 'GENERAL HEATING PERFORMANCE Model: YSC048G Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 187-253 MCA: NIA H eat in g 1.1 o del: Medium U nit P rim ary Voltag e: 208 MFS: NIA Unit Secon dary Voltage 230 MCB: NIA H eating Input(BTU): 80,000 Unit Hertz 60 Heating 0utput(BTU): 65,600 Unit Phase: 3 tic Burners 2 N o.Stages 1 EER/SEER 12.0/14.0 Standard I.I otor Field Installed Oversized 1.1 otor Gas Inlet Pressure MCA 25.4 MCA N/A I atu ral Gas QJ in/M bq: 4.5/14.0 I.IFS: 35.0 MFS: N/A LP(M in/M az) 11.0/14.0 1.1CB: 35.0 1.1CB: N/A Gas Pipe Connection Size: 112" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized 61 otor Number 1 Number. N/A Number: N/A Horsepower 1.0 Horsepower N/A Horsepower: N/A MotorSpeed(RPL1): _ 1.1 o tor S pe ed(RPM Y N/A 1.1 otor Speed(R P 1.1): N/A Phase 1 Phase N/A Phase N/A Full Load Amps: 6.9 Full LoadAmps: N/A Full LoadAmps: N/A Lo cked R otorAmps: _ LockedRotorAmps: N/A LockedRotorAmps: N/A COMPRESSOR Circuit 1,2 OUTDOOR MOTOR Number: 1 Number 1 Horsepower. 3 E H orsepov&r: 0.33 Ph ase. 3 1.1 oto r Speed(RPM): 1100 Rated Load Amps: 13.7 Phase: 1 Locked Rotor Amps: S3.1 Full Load Amps: 1.4 Locked RotorAmps: 4.6 POWER EXHAUST ACCESSORY FILTERS REFRIGERANT 12 (Field Installed Power Exh Bust') Type R-410 Phase: N/A Type. Throvavay Horsepower: N/A Furnished: Yes Factory Charge MotorSpeed(RP1.1): NIA Number 2 Circuit#1 Full Load Amps: N/A Recommended 20-x35"xY Circuit#2 N;A Lo cked Rotor Am ps: N/A NOTES 1.M aximu m i HACR Y Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.Fora more precise value,see unit nameplate and ser.ice instru cticn s. 3.Value does not include Power E xh aust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AH RI conditions and in accordance with D 0 E test procedures. 2017-08-02T16:51:23 Page 5 of11 Job Name:. Preared By:. TINE® UnP Tag:YSC048G3RMA21 Quantity:1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 68.0 lb MOTORIZED OUTSIDE AIR DAMPER C D MANUAL OUTSIDE AR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR P OWE REXHAUST 7HROUGHT THE BASE E LE CTRICAUGAS(FIOPS) UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 0, UNIT MOUNTED DISCONNECT(FIOPS) 1 POWERED CONVENIENCE OUTLET(FIOPS) HINGED DOORS(FIOPS) \A HAILGUARD O SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEELHEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET O 205.OIb J 46.0 Ib (E)LENGHT (F)WIDTH 598.0lb 492.OIb O 183.OIb SS.OIb 33" NOTE: 1. Al weights areappropmate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of u nit. 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/-10%of th a nameplate weight.. 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. N eUShipping weight of optional accessories should be added to unit weight when ordering factory or 5eld installed accessories J e e E 6 F 0 PACKAGED GAS/ELECTRICAL RIGGING AN D CE NTE R OF GRAVITY 2017-08-02T16:51:23 Page 6 of11 Job Name:. Prepared By: TllA E® Unit Tag:YSC048G3RMA21 Quantity:1 CLEARANCE FROM TOP OF UNIT 72' CLEARANCE 36" CLEARANCE48" SUPPLY RETURN s DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE36" PACKAGED GAS ELECTRIC CLEARANCE ROOF OPENING I I UNR OUTLINE I I I I I 40 — 68 116 PACKAGED GASrELECTRIC DOINNFLOIN TYPICAL ROOF OPENING 2017-08-02T16:51:23 Page 7 of11 Job Name:. Prepared By: TllA E® Unit Tag:YSC048G3RMA21 Quantity:1 ea ECONOMIZER HOOD e ea BAROMETRIC RELIEF HOOD ECONOMIZER HOOD 29" 6" 8 3/4" 19" LOW LEAK ECONOMIZER HOOD ACCESSORY 2017-08-02T16:51:23 Page 8 of11 TRANS® Job Name:. 4- Prepared By:. Unit Tag:YSC048G3RMA21 Quantity:1 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 81/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71/2 to 81/2 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 2017-08-02T16:51:23 Page 9 of 11 TRANS® Job Name:. AA Prepared By:. Unit Tag:YSC048G3RMA21 Quantity:1 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions 2017-08-02T16:51:23 Page 10 of 11 Job Name:. Prepared By: T/?ANE® Unit Tag:YSC048G3RMA21 Quantity:1 (Gas/Electric Only). Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to 50°F before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). 2017-08-02T16:51:23 Page 11 of 11 Date: Weights: Units: YSC 060E Part Number: g ( micrometl 7/13/2017 112lbs/50.8kg ECD-PRCOBCA-DYDB Submitted To: Job: Notes: Economizer- Ultra Low Leak Economizer, Vertical Orientation, Belimo Zip - Single/Multiple Speed Electromechanical, Adjustable Dry Bulb Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. Controller and actuator located on this side of economizer. O O O •� �19.5" a o a Q . Outside air sensor � o 0 Stainless steel blade ® o side seal on return and outside air blades. oa 0 0 0 0 External, gear driven dampers. Side View The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC--Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC--Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800 gmicrometi Date: Weights: Units: YSC 060E Part Number: 7/13/2017 112lbs/50.8kg ECD-PRCOBCA-DYDB Submitted To: Job: Notes: Economizer- Ultra Low Leak Economizer, Vertical Orientation, Belimo Zip - Single/Multiple Speed Electromechanical, Adjustable Dry Bulb Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. Compliant Economizer: 1. Title 24: Economizers meet California Energy Commission Title 24-2013/2016 prescriptive section 140.4(damper leakage etc.),and mandatory section 120.2.i for Fault Detection and Diagnostic controls(Zip Economizer BZE1245). 2. ASHRAE 90.1: Economizers meet ASHRAE 90.1-2013/2016 damper leakage requirements as stated in Table 6.4.3.4.3.,and meet 2016 Fault Detection and Diagnosis requirements in section 6.4.3.12. 3. IECC: Economizers meet IECC 2012 section C402.4.5.2 and, IECC 2015 sections C403.2.4.3 and C403.3.3.5 for outside air,return air,and relief damper(when provided)leakage requirements,and IECC 2015 section C403.2.4.7 for Fault Detection and Diagnostic requirements. Note: IECC 2015 section C403.2.4.7.1 requires differential return air sensor,which must be ordered separately. 4. AMCA:Outside air and return air(volume)dampers are AMCA Class 1A rated at 1"w.g. Refer to MicroMetl NS1 catalog sheet on web site for details. Relief air dampers(when provided)are also AMCA rated. Refer to GR1 series catalog sheet on web site for details. Features: • Gear driven design for trouble-free operation,eliminating slippage and binding associated with standard linkage. AIR • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. i!KT • Rainhood is sloped for water run-off. rrxrortmR R • Power exhaust options available. • Logic wiring is field supplied and installed between the commercial 2 stage thermostat and HVAC low voltage terminal board. MicroMetl Corporation certifies that the models GR1 and NS1 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC--Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC--Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800 Date: 04/10/2026 Perm t#: 1673 Permit Date: 09/28/2017 Review Date: 09/28/2017 Perm it Type: COMM IRCIAL MECHANICAL Review Type: COMM 1RCIAL MECHANICAL Target Date: 10/05/2017 Scheduled Time 00:00 Com pleted Date: 10/03/2017 Description: Need Info On Econom Ver,Approved With Econom yer,10/9/17 KO. Review Status: Assigned To: BUILDING Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information Parcel#: 31052100302700 R ainydaze Properties, LLC Rainydaze Properties, LLC P .O. Box 29408 3617 172ND ST NE B ellingham,WA98228 Zoning: 599 Other Retail Trade NECLot: Block: 2 06-914-8888 Permit#: 1673 Permit Date: 09/28/17 Permit Type: COMM IRCIAL M ECHANICAL Project Nam e Zoet Fam iy Restaurants, LLC Applicant Nam a Foss Heating and Cooling Applicant Address: PO Box 29408 Applicant, City, State, Zip: Mount Vernon,WA98273 Contact: Abrahm Rollins Phone: 206-914-8888 Em al: orders@fossheating.com Scope of Work: Replace two RTU Valuation: 18000.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wrier Nam e Omer Phone Zoning 31052100302700 3 617 172ND ST NE Rainydaze 206-914-8888 599 Other Retail Properties,LLC Trade NEC Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# Foss Heating and 333 E Blackburn CONSTRUCTION Cooling,Inc 360-336-1517 Road CONTRACTOR Labor&Industries FOSSHCI9858A Inspections Date I nspection Type D escription S cheduled Date C om lieted Date I nspector S tatus CIO. 01/23/2018 MECHANICAL installation com Bete. 0 1/22/2018 B UILDING A pproved ROUGH-IN Plan Reviews Date R eview Type D escription A ssigned To R eview Status 09/28/2017 COM M aCIAL Need Info On Econom zer,Approved With BUILDING MECHANICAL Econom zer,10/9/17 KO. Fees Fee D escription N otes A m aunt Mechanical Com m ecial Plan Review T able 4-1 $250.00 Total S250.00 Attached Letters Date Letter D escription 10/09/2017 Building Perm i Paym mts Date Paid By D escription P aym ant Type A ccepted By A m aunt 10/12/2017 Abrahm Rollins 6 6853787 c c $250.00 O ntstanding Balance $0.00 Notes Date Note C reated By: Em tiled Foss heating: We are reviewing the Corn m ecial M ochanical Application that was subm ited on 9/28/2017.To further the review,we need inform ztion on the econom'ser.If you do not have inform Aion on 10/03/2017 the econom zer,please reference the code section being applied. Launa Black Thank you, LP Uploaded Files Date File Nam e 10/06/2017 2680155-Econom zer Subm ital Lpdf 10/06/2017 2680156-Econom zer Subm ital 2.pdf 09/28/2017 266068 1-Packaged Unit 2 Specifications.pdf 09/28/2017 2660682-Packaged Unit 1 Specifications.pdf 09/28/2017 2660665-1673 Application.pdf Job Name:yy red MAIME' Unil'Tap:g5C048G3RMA21 Juan ity:1 Trane Precedent Gas/Electric Packaged Rooftop Unit Overview-YSC048G3RMA**KOOOOOOOGIOOOOOOOOOOGOOOOOO Application Unit Size Supply Fan`. W External Dimensions(In_iiiiiiiiiiiiiiiiiiiiiii1lheight I EER IEER/SEER External .m_ DX cooling Airflow Static Height Width Length Minimum Maximum t2 0 EER 14 00 gas heat 4 Ton(048) Pressure 1600 cfm 0.500 in H2O 3.41 it 3.69 it 5.82 it 492.0 lb 348 kg Fresh Air Selection Low Leak Econ-dry bulb 0- 1001%/bar rel 3p Supply Fan/Drive/M otorTy pe Standard drive motor Panels/Filters Standard condenser coil Unit Electrical Voltage/phase/hertz 208.230/60/3 MCA 25.40 A MOP 35.00 A Unit Controls Microprocessor controls 3ph Communications Option Without communications System Monitoring Controls 1 Without system monitoring controls System Monitoring Controls 2 No monitoring controls Entering Dry Bulb 80.00 F Capacity Entering Wet Bulb 67.00 F Gross Total 48.90 MBh tr Ambient Temp 95.00 F Gross Sensible 38.78 MBh Leaving Coil Dry Bulb 56.90 F Net Total 47.41 MBh Leaving Coil Wet Bulb 56.90 F Net Sensible 37.29 MBh Leaving Unit Dry Bulb 58.78 F Fan Motor Heat 1.49 MBh Leaving Unit Wet Bulb 57.63 F Refrig Charge-circuit 1 3.1 lb Refrigeration System Options Leaving Dew Point 56 91 = Heating Section Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 65.60 MBh " Output Heating Capacity with Fan 67.50 MBh Heating EAT 70.00 F Heating LAT 108.20 F Heating Temp Rise 38.20 F 2017-08-02T16:51:23 " M"i• 'Prepared . Prepared By:. Urnt Taq:vSCp18G3RMA21 l�nn6r:-t 1 n Indoor Fan Data �,9.a. • Outdoor Fan Data Type FC Centnlugal... Type Propeller Drive Type Direct Fan Quantity 1 Indoor Fan Performance Drive Type Direct Airflow 1600 cfm Outdoor Fan Performance Design ESP 0.500 in H2O Condenser Fan FLA 1 40 A Indoor Motor Operating Power 0.61 bhp Exhaust Fan Data Indoor Motor Power 0.45 kW Type FC Centnfi,,gal Indoor RPM 1028 rpm Drive Type Direct Indoor Fan FLA 1 40 A Exhaust Fan Performance Exhaust Fan FLA 6 90 A Power 0.00 kW Circuit 1 RLA 13.70 A Circuit 2 RLA 0.00 A Compressor parts Nowe Parts less compressor warranty None 2017-08-02T18:51:23 rM WE Job Name . 0 Prepared 8yy:. Unit Tag:VSC048G3RMA21 Ctuantity I TOP PANEL CONDENSER FAN EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN(ALT) 3/4'-14 NPT DIA HOLE ONDENSER COIL O 4 1/4' 278I18' NIT CONTROL WIRE 7/8'DIA HOLE 42114" SERVICE GAIJGE PORTACCESS I318'DIA.HOLE NIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE \-17Y NPT GAS CONNECTION CONDENSATE 23 1!T 6 NOTES 1 TH RU-THE-BASE GAS AND ELE CTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFYWEIGHT.CONNECTION.AND ALLDIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION I____ I I I I I RETURN 24' I SUPPLY I 18' 1 I I I _ 1_4• JLis1JY' III., 14' E35/8' PLAN VIEW UNIT DIMENSION DRAWING 407/6' RETURN 231/4' HORIZONTAL AIR FLOW SUPPLY 11314" 20 S 5/8' 1/4' 9SB 4 3/4' 17 114 8 718' 13 1/4" 16' 4 114' 69 TB' 5 9116" CONDENSATE 7W 44 114' PACKAGED GAS/ELECTRICAL DIMENSION DRAWING 2017-08-02T 16:51:23 Page 3 of 11 . RWi• Job Name: Prepared By Unit lag:VYC048G3RMA21 Quantity:1 SUPPLY RETURN 3J4'-14 NPT DRAIN CONNECTION \23 9116" \4 V 4' ISOMETRIC-PACKAGED COOLING Page 4 o1 11 2017.08-02T16 5 1:23 Jab Name:. TE' Prepared Byy Unit Tag:VSC048G3RMA21 Ouantiry:1 ELECTRICAL/GENERAL DATA GENERAL M4)(s) HEATING PERFORMANCE Model. YSC048G 0versi zed Motor HEATING-GENERAL DATA U nd Operating Voltage 187-253 MCA. NIA Heatng Model Medium U nit Primary Wltage: 208 k1 FS-. NIA H eating input(STU): 50.000 U nit Secondary Voltage 230 MCB. NIA Heating Output(BTU) 65600 Unit Hertz. 60 No.Burners 2 UmtPhase 3 No Stages 1 EER/SEER 120114 0 Standard Motor Feld Installed Oversized M otor Gas Inlet Pressure CA 25A MCA NIA Natural Gas(Min/M ei) 4.5/14.0 M 61 LP(Mnax) 11.0114.0 MC 5. MFS NIA MCB: 350 MCB NIA Gas Pipe CdnnecUon Sizn. tIT INDOOR MOTOR Standard Motor Oversized Motor Feld installed Oversized Motor Number 1 Number NIA Number NIA Horsepower 1 0 Horsepower NIA Horsepower. NIA Motor Speed(RP M) _ Motor Speed(RPM) MIA Motor Speed(RPM) NIA Phase 1 Phase NIA Phase NIA F UII Load Amps 6.9 Full Load Amps. NIA Full Load Amps NIA Locked R otorAmps _ Locked RotorAmps NIA Locked Rotor Amps NIA COMPRESSOR Ciralt 112 OUTDOOR MOTOR Number 1 Number. 1 Horsepower. 36 Horxpo war 033 Phase 3 M otor Speeei(RPM)-. 1100 Rated Load Am psi. 137 Phase 1 Locked Rotor Amps 831 Full Load Amps: 14 Locked RotorAmps 46 POWER EXHAUST ACCESSORY (31 FILTERS REFRIGERANT (2) (Feld Installed Power E)Maust) Type R-410 Phase NIA Type Throwaway Faco Char ge Horsepower NIA Furnished. Yes ry C.-tot 3 Motor Speed(RPM) NIA Number 2 Crcud rt MIA F ull Load Amps NIA Recommended 20'k35'k2 Locked Rotor Amps NIA NOTES- 1 Maximum(HACR)Circuit Breaker sizing is for matallabi,its in the U n led States ony. 2.Retigerent charge is an approximate value For a more prease value,see unit nameplate and service instructions 3.Value does not include Power E#laust Accessory 4 Value includes oversized motor 5 Value does not nckide Power E)Maust Accessory 6 E E R is rated at AH RI conditions and in a cm rdan ce wth DOE test procedures. Page 5 of 11 2017.08-02T 16 51 23 �/��` Job Name: y MAIN a Unit Tag BSCWWRMA21 C Uanbty:1 INSTALLED ACCESSOMES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 680 b MOTORIZED OUTSIDE AIR DAMPER C D M AMU AL OU TSIDE AIR DAM PER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST O B TM ROUGHT THE BASE ELE CTRICALIGAS(FIOPS) UNIT MOUNTED CIRCUIT BREAKER(FIOPS) UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) HINGED DOORS(FIOPS) A HAILCUARD B SMOKE DETECTOR,SUPPLY!0.E TURN PACKAGED GAS/ELECTRICAL NOVA-CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT B ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET .0Ib © 16.Ob (E)LENGHT AO 205 �(F�)WID�TM 598.010 a92010 � 183 01D O 58.0 D 33' I y- I OTE 1. Atlweightsare apprommate. 2 Weigh is for optionsthat are not[at refer tolnlala6on guide 3. The actual velght are listed on the unit nameplate ♦. Refer to unit nameplate and nstalation guide for weights before scheduling transportaton and installation ofumt 5 The v eightshuwn representsthe tygcal unit operating weight brthe configuration sefeded Estimated at�1-10%ofthe nameplate weight 6. Veny veght,connedion,and al dimension vith installer documents before installation 7. Corner weights are given IN mbrm at on only 8. NeVShipping weight of opt on at accessones sh ou to M added to unl weight vnen ardenng factory or told installed accessories J F PACKAGED GAS/ELECTRICAL RIGGING AND CE NTE R OF GRAVITY Page 6 of t 1 2017-08.02T16:51:23 rMN • U Name:. Prepa,ed Byy Unit Tag:VSCO38G3RMA21 Urar-bty:1 CLEARANCE FROM TOP OF UNIT 72' CLEARANCE 36" CLEARANCE 48" SUPPLY RETURN DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING I 1 UNIT OUTLINE I I 3r 44 VT I I I 40' 68 3116 PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING Page 7 of 11 2017.08-02T 16.51,23 Job Name:. MANE Prepared EIy Unit Tag:VSCOs8G3RMA21 OuanGty:1 \ t CONOMIZER HOOD 00 —BAROMETRIC RELIEF H000 CONOMIZERHOOD 29' 0 8. 00 00 8 31t' 1 g' LOW LEAK ECONOMIZER HOOD ACCESSORY Page 8 of 11 2017.08-02T16:51:23 :. MANE' aneca.ea ay UnitJob N Tagame:VSC048G3RMA21 ouannry:1 General The units shall be convertible airflow. The operating range shall be between 1 15°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 6117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 7'/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8'/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71/2 to 81/2 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Un'Name: 0 TR�LII/E" Prepared ay Unit Tay:VSCA18G3RMA21 O bly:1 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions name:. TRINE' PreparedB Unit Tag:VSCOd8G3RMA21 Quantity:1 (Gas/Electric Only). Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to WF before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). 2017-06-02T16:51:23 Page 11 of 11 Job wage: TRANE' Prepared Byy Unit Tag:vSC036G3EMA00 Quantity:1 Trane Precedent Gas/Electric Packaged Rooftop Unit Overview- „0000 Application Unit Size Supply Fan External Dimensions On.) Weight EER IEER/SEER External DX cooling, 3 Ton 036 Airflow Static Height Width Length Minimum Maximum 12.0 EER 1400 gas heat Pressure 1200 cfm 0.200 in H2O 3.41 it 3.69 it 5.82 it 472.0 lb 339 kg Fresh Air SeNctlon Without fresh air selection SupplyFeNDritro!MotorType Standard drive motor Panels/Fllters Standard condenser coil Voltage/phase/hertz 208-230/6013 4 MCA 19.90 A ` r MOP 30.00 A Unit Controls Electro mechanical controls 3ph k; Communications Option Without communications System Monitoring Controls 1 Without system monitoring controls System Monitoring Controls 2 No monitoring controls • • Entering Dry Bulb 80 00 F Capacity w �- Entering Wet Bulb 67.00 F Gross Total 37.01 MBh Ambient Temp 95.00 F Gross Sensible 29.82 MBh Leaving Coil Dry Bulb 57.21 F Net Total 36.37 MBh Leaving Coil Wet Bulb 57.21 F Net Sensible 29.19 MBh Leaving Unit Dry Bulb 58.69 F Fan Motor Heat 0.63 MBh Leaving Unit Wet Bulb 57.78 F Refrig Charge-circuit 1 2.9 lb Refrigeration System Options Leaving Dew Point 57.21 F Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 65.60 MBh Output Heating Capacity with Fan 66.47 MBh Heating EAT 70.00 F Heating LAT 120.80 F Heating Temp Rise 50.80 F 2017.09-08 22:00-31 Z - Job Na.:. TRAWE' Prepertd Byy:. Unit Taq:VSC036G3EMA00 Quantity 1 Fan • _ �� Indoor Fan Data Outdoor Fan Data Type FC Ce,!-i! ,e,! Type Propeller _ Drive Type Direct Fan Quantity 1 Indoor Fan Performance Drive Type Brect r Airflow 1200 cfm Outdoor Fan Performance j Design ESP 0.200 in H2O Condenser Fan FLA 1 10 A indoor Motor Operating Power 0.26 bhp Exhaust Fan Data Indoor Motor Power 0.19 kW Type FC Centrifugal Indoor RPM 769 rpm Drive Type Direct Indoor Fan FLA 1.10 A Exhaust Fan Performance Exhaust Fan FLA 5.70 A Compressor Section Power 0.00 kW Circuit 1 RLA 12.80 A Circuit 2 RLA 0.00 A Pape 2 of 10 2017-09-08 22:00:31 Z Jot)Name:. TRANE' Prepared SKy:. UMt Tag:YSCA38G3EMAfX1 OuanOty:1 TOP PANEL CONDENSER FAN EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN(ALT) 314"-14 NPT DIA HOLE - ,--CONDENSER COIL 4 114' 23 9/18' UNIT CONTROL WIRE 718"DIA HOLE 42114' SERVICE GAUGE PORTACCESS 13B•DIA MOLE UNIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE 1t2'NPT GAS CONNECTION CONDENSATE 23 1!t NOTES 4 3116' 1 TH A-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VER IFY WE IGHT,CO N N ECTI ON.AND ALL D IME NSIO N WITH INSTALLER DOCUMENTS BEFORE INSTALLATION r____ I I I I I RETURN I 78' I I SUPPLY I I I IS l2" 9 1/4' 11" 13 5/8' PLAN VIEW UNIT DIMENSION DRAWING 7 o E:�/ 40 7/8 HORIZONTAL RETURN 231/4' AIR FLOW SUPPLY 1431C 201/P 9 sar S S/8 4 N4' ti 87B' 131/4' 3 30 6' 4 114' 69718' 59116' CONDENSATE T SB" 44 1/4" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING Page 3 of 10 2017-09.08 22:00:31 Z Job Name:. TRANS` Prepared By Unit Tag:VSC036G3EMA00 Quantity:1 B SUPPLY RETURN 3/4'-74 NPT j DRAIN CONNECTION 23 9116' \41/4' ISOMETRIC-PACKAGED COOLING Page a of 10 2017-09-08 22-00-.31 Z Aawk �/� e Job Flame T - 1 tV' N � Unn�Tag:IY3636WEMA00 puantity 1 ELECTRICAL/GENERAL DATA G&JERAL HEATING PERFORMANCE Model YSC036G Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage 187-253 MCA N/A U nit Prm ary Voltage 208 MFS NIA Heating Model Medium Unit Secondary Voltage 230 MCB NIA Heating Output(BInput U 65,600 U nrt Hertz 60 H eating Output(BTU) 65,600 Unit Phase 3 No Burners 2 No.Stages 1 EE RISE E R 12 0/14 0 Standard Motor Feld Installed Oversized Motor Gas Inlet Pressure MCA 199 MCA NIA N atural Gas(sfiNMa) 451140 MFS 300 MFS N/4 LP(M nlMex) 1101140 MCB- 300 MCB NIA Gas Pipe Connection Sae 112- INDOOR MOTOR Standard Motor Oversized Motor Feld Installed Ovenzed Motor $lumber 1 Number NIA Number NIA Horsepower 0.75 Horsepower NIA Horsepower NIA Motor Speed(RPM). — Motor Speed(RPM) NIA Motor Speed(RPM I NIA Phase 1 Phase NIA Phase N/A Full Load Amps NIA Full Load Amps NIA Locke ad Amp3 5.7 Locked Rotor Amps NIA Lo�edRotorAmps _ Locked Rotor Amps NIA COMPRESSOR Circut 12 OUTDOOR MOTOR Number 1 Number i Horsepower 26 Horsepower 025 Phase 3 Motor Speed(RPM) 1100 Rated Load Amps 1118 Phase 3 Locked Rotor Amps 950 Full Load Amps 11 Locked Rotor Amps 36 POWE R EXHAUST ACCESSORY (3) RLTERS REFRIGERANT (2) (Feld Installed Power E)ir ausl) Type R-110 Phase NIA Type 7hroveweY Factory Charge Horsepower NIA Furnished Yes Motor Speed(RPM) NIA Nuni 2 Crcutt al 3.2b Full Load Amps NIA Recommended 20k35Y2 Crcurt 62 NIA Locked Rotor Arnps N/A NOTES 1 M aximum(HACR)Circuit Breaker sizing is br tristallatlons in the United Slates only. 2 Rekigeranl charge a an approxm ate value For a mom Precise value,see unit nameplate and service instructions 3 Valuedoesnotnctude Power E)Maust Accessory a Value tndodes oversized motor 5 Value does not include Paver E Alaust Accessory 6 E E R is rated at AH RI co ndrto ns and in a cco rdan m wth DOE test procedures Page 5 01 10 2017-09.08 22:00:31 Z Job Name: MAW' Unit B. Unit Tag:VSC0.36C3EMA00 Quantity:1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER MANUALOUTSIDE AIR DAMPER DM OMETRIC RELIEF OVERSIZED MOTOR O BELT DRIVE MOTOR 0 POWER EXHAUST THROUGH T THE BASE E lF CTR ICAL/GAS(FIOPS) UNIT MOUNTED CIRCUIT BREAKER(FIOPS) UNIT MOUNTED DISCONNECT(F10P5) POWERED CONVENIENCE OUTLET(FIOPS) HINGED DOORS(FIOP S) �' HAILGUARD B SMOKE DETECTOR,SUPPLVf RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEATEXCMANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVIT SHIPPING NET AO 193 DID © aS.OD (E)Lf NGHT ¢1WN)TH 57T 01D 172.0 ID � 17B 01D Q SS D b 33• U OTE 1. All weights a re a pprommate 2. Weights for o pitons t hat are not let re far to In stafabon guide 3. The actual weight are/steel on the unit nameplate A. Reler to unit nameplate and nslalabon guide br weights Debre scheduling bansportabon and Installation ofunit 5. The weght shove represents the typical unit operating weight air the configuration seladed Estimated at•1-1 D%of th a nameplate we gh t B. 'Any we ig III,tonne d on,and al dimension wth installer documents Debre Installation. T. Corner weights are given for mbenaton only a NeUShipping weight of optional accessories should W addedto unit weight Men ordering%Crory or feed installed accessories J E F PACKAGED GAS I ELECTRICAL RIGGING AND CE NTE R OF GRAVITY Page 6 of 10 2017.09-08 22-00:31 Z Job Name.AMA _ TMME' U-d Ta :Y8y Unit Tag:VSCA36G3EMA00 OuanUry,l CLEARANCE FROM TOP OF UNIT 72' CLEARANCE 36- CLEARANCE48- Su LY RETURN DOWNFLOW CLEARANCE 36' HORIZONTAL CLEARANCE 18- CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING---- UNIT OUTLINE I I 3r I 44 VT 1 I I Z40' 68 3/16' PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING 2017-09-08 22:00.31 Z Page 7 of 10 ���/r JCA Name. rRANE' Byy Preparetl :. Unn Tap:vSC03563EMA00 Ouanuty:1 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 81/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71/2 to 81/2 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Jab Name:. TRWE' P epared By:. Unit Tag.v5C036G3EMA00 9uanCty 1 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions Job Name: Ty /?/'�/_`• PUnd fgmry BSC036G3EMA00 Quanury:I (Gas/Electric Only). 2017-09-O8 22:00:31 Z Page 10 of 10