HomeMy WebLinkAbout4008 174th Pl Ne_BLD440_2026 1 CITY OF ARLINGTON j 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 B iTlL DIM; G` Address:ous 174th Place NF. Parcel 9:009347000015 00 Permit#:440 _ Valuation 0.00 PLICANT �' _ _ ` CONTRACfiOIi .�, Name:NELSON WAI.'rER A&DARDARA L Name:Brennan Heating Address;4008 174TH PL NE Name Brennan Heating Address:4601 S 134th Place City,State Zip.ARLINGTON,WA 98 2 23-3 705 City,State Zip:Seattle,WA 98168 Address:460! 5 I34th Place Phone: City.Slate Zip:Seanle,WA 98168 Phone:206-248-7900 Phone:206-248-7900 �.... ..-._ :�. .•' � _ }'�:f:=�r�:��f2ri�'.'-' 1. ,�� a�* .� � r.Fi�� r 3^• Name;Brennan Heating Address:4601 5 134th Place Name: I City,Slate,Zip:Senule,WA 98168 Address: Phone:206-248-7900 City.Stale,zip_ E.XP LIC#.BRENNHA971R<J Phone. _ : 12/29/2015 LlC# SUB bES-CRII T10_N s ►� ; exP: PERMIT TYPE- _. � i�"`.:L-•.- ��y;r,� Residential Mechanical CODE YEAR: 2012 j STORIES: 1 i DWELLING UNITS; 1 CONST_"TYPE, OCC GROUP � BUILDINGS: �p OCC LOAD: - PERMIT'APPROVAL I HERE Y; COMPLY WI l li Cl"I Y AtiD Sl Al L LAWS REGULATING CONSTRIKC t ION AND IN DOING I t{F WORK AI TI I IORIZEr)tw THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WOKKNIEN'S COMPENSATION ION INSURANCE AND RCW 18 27• THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL,OR HIS/HER DEPUTY AND ALL FEES ARE.PAID• IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL.OR A CERTIFICATE OF OCCUPANCY I[AS BEEN GRANTED, 113C110/IRCI 10. X11E*S TAX ity OrAt'it to NOTICE:Sales an coded C lax relating to c0nstrulotiou and constr m iction atcriafs m the City rA u#3101. iR on must he o e el on your sales tax retain r nit ( 14 . Print Name Da c Released By Date CONDITIONS Requirements: 3" Concrete pad with seismic bracing attached to pad, Provide electrical disconnect. Lines shall be insulated and adhesive tapes are not permitted_ G4032.8.1 THIS PERMIT Al1THORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO DI-:DUNG ON PRI VATE PROPGR'l Y ONLY• ANY CONSTRUCTION ON TILE PUBLIC DOMAIN(CURBS,SILUEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARA'rE PERsM1SSION• Date PERMIT Description FEES ., , -,•� ia t�., -� -i•'yigy 8/4/2014 Mechanical Fee(Enter Fixture Fee) Fee Amount 8/4/2014 Mechanical Permit Base Fee $25.00 $25M Total Due: S50.00 Total Payment: $0,00 CALL FOR INSPECTIONS Balance Duc: S50.00 BUILDING t360)403-3417 i� �. CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 © , PHONE; (360) 403-3551 BUILDING PERMIT Address:4008 174th Place NE Permit#:440 Parcel#:00934700001500 Valuation:0 00 OWNER APPLICANT CONTRACTOR Name:NELSON WALTER A&BARBARA L Name: Brennan Heating Name: Brennan Heating Address:4008 174TH PL NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223-3705 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#: BRENNHA97I R9 EXP: 12/29/2015 LIC#: EXP JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: 1 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City f Ar i ton must be ted on your sales tax retunt f rm and coded City of Arlington#3101. qoclr Signature Print Name Date Released By Date CONDITIONS Requirements: 3" Concrete pad with seismic bracing attached to pad. Provide electrical disconnect. Lines shall be insulated and adhesive tapes are not permitted. C403.2.8.1 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES _ Date Description Fee Amount 8/4/2014 Mechanical Fee(Enter Fixture Fee) $25 00 8/4/2014 Mechanical Permit Base Fee $25 00 Total Due: S50.00 Total Payment: $0.00 Balance Due: S50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 i When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: IV\ Project Description:��_ �� — -kOYI Owner: Address: Phone: ��p- �oJ q rJ� �`� Email: Applicant: Brennan Heating Address:4601 S 134th PI Seattle 98168 Phone: 206-248-790 Email: Jaimie@brennanheating.com Applicant Signatur Electronic Signature if submitting on-line l hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration:1 2/29 O � — Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY l Permit#: Accepted by / _ Date: /// Received AUG 0 4 2014 i i RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE • Arlington, WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace(80+) Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank i AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [� Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances trt w c m r� m 0 �s I 1 SPECIFICATIONS General Model No. XC17-024 XC17-030 XC17-036 XC17-042 XC17-048 XC17-060 Data Nominal Tonnage 2 2.5 3 i-5 4 5 Connections Liquid line(o.d.)-in. 3/8 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.)-in. 3/4 3/4 7!8 7/8 7/8 1-1/8 Refrigerant 'R-410A charge furnished 7 Ibs.14 oz. 8 lbs. 0 oz. 7 lbs. 12 oz. 7 lbs. 14 oz. 12 lbs. 12 oz. 12 lbs.14 oz Outdoor Net face Outer coil 23.25 27.21 27.21 27.21 27.21 27.21 Coil area-sq. ft. Inner coil --- --- --- 26.36 26.36 Tube diameter-in. 5116 5/16 5/16 5/16 5/16 5/16 No. of rows 1 1 1 1 2 2 Fins per inch 26 26 26 26 22 22 Outdoor Diameter-in. 26 26 26 26 26 26 Fan No.of blades 5 5 5 5 5 5 Motor hp 1/3 1/3 1/3 1/3 1/3 1/3 Cfm 2650 3055 4025 4025 4230 4230 Rpm 400 450 600 600 675 675 Watts 37 53 122 122 185 185 Shipping Data-lbs. 1 pkg. 263 285 286 311 344 349 ELECTRICAL DATA Line voltage data-60hz-1 ph 208/230V 208/230V 208!230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection(amps) 30 30 30 40 50 50 'Minimum circuit ampacity 20.0 20.0 20.0 24.4 29.3 33.3 Compressor Rated load amps 13.5 12.8 14.1 17.9 21.8 25.0 Locked rotor amps 58.3 64.0 77.0 107.0 117.0 134.0 Power factor .97 .98 98 .93 .96 .98 Outdoor Fan Motor Full load amps 2 2 2 2 2 2 CONTROLS iComfort Wi-Fig'Thermostat 1OF81 'Remote Outdoor Temperature Sensor X2658 (for dual fuel and Humiditroll) °Discharge Air Temperature Sensor 8BK38 ComfortSense®7000 Thermostat Y0349 Outdoor Temperature Sensor-for X2658 - ComfortSense 7000 Thermostat OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Hard Start Kit 88M91 Freezestat 3/8 in.tubing 931335 1 5/8 in.tubing 50A93 Indoor Blower Off Delay Relay 58M81 5 Low Ambient Kit 68M04 Refrigerant L15-41-20 L15-41-40 Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 L15-65-50 Field Fabricate NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge sufficient for 15 Q.length of refrigerant lines. 'HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements Remote Outdoor Sensor may be used with an icomfo&-enabled outdoor unit for a secondary(alternate)sensor reading,sensor may also be used with a conventional outdoor ur*, 'Optional for service diagnostics. Freezestat is recommended with Low Ambient Kit. l Ar XC17-2 to 5 Ton Air Conditioner I Page 11 i f I 1 3 I I r ii CITY OF ARLINGTON_ t 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 4 PHONE; (360)403-3551 ::. _v Address:4008 174th Place N"E BUILDING PERMIT Parcel#:00934700001500 Permit#:440 ` r .. . Valuation:0.00 APPLICANT C.ONTRAC Name:NELSON WALTER A&BARBARA L blame:Brennan Heating Address:4008 174TH PL NE Name:Brennan Heating 1 Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98 2 23-3 705 City,State Zip:Seattle,WA 98168 i Phone: City,State Z.ip:Seattle,WA 98168 Phone:206-248-7900 Phone:206-248-7900 M-,4CH,ANICAJI-C_ TRE1CTOR � .i Name Brennan Heating PLUN�BUNG CONTiZACTO Address:4601 S 134th Place Name. City,State,Zip:Seattle,WA 98168 Address: Phone:206-248-7900 City,State,Zip: LIC#.BRENNHA97I R9 Phone: EXP: 12/29/20I5 ["IC# FXP JOB DESCRIPTION T. :- PERM(TTYPE: Residential Mechanical CODE YEAR: 2012 STORIES: 1 CONST.TYPE; DWELLING UNITS; l OCC GROUP: BUILDINGS: 1 ���/ t�lOCC�rLOAD: PERMIT PRV�■VAI�„; [AGREE'f0 COMPLY Wffh(CITY AND STATE LAWS REC;IILATING i ONS"fRUCTION AND IN DO{NG THE WORK A+SUT�HORI7,ED TfiEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASH[NGTON RELATING TO WORKMEN'S COMI'ENSA"f[OA1 1NS[JRANCE AND RCW 18.2Z. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BU[LDING OFF[C1AI,OR HISMER DEPUTY AND ALL FEES ARE PAID. Cf l5 UNLAWF'UL'1'O USE OR OCCUPY A BUILDING OR STRUCfURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL.OR A CERT(FiCATE OF OCCUPANCY HAS BEEN GRANTED, IBC 110ARC I I0, LES TAX NOTICE:Sates tax relating to construction and construction materials in the City F A;` ton must be te(¢an your sales tax retut»'f t an coded City of Ar"n ton#3101. C - Signature / t Print Name Date Released By Date € K � attached to I RAW Requirements: 3" Concrete pad r with seismic bracing _ �� _ pad Provide electrical disconnect. Lines shall he insulated and adhesive tapes are not permitted. C403.2.8.1 THIS PERMIT AUTHORIZE ONLY THE WORK NOTED,T141S PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES ,w ,M Date Description 8/4/2014 Mechanical Fee(Enter Fixture Fee) Fee Amount 8/4/2014 Mechanical Permit Base Fee $25.00 $25,00 Total Due: $50.00 Total Payment: $0.00 CALL FOR INSPECTIONS Balance Due: $50 00;' I3U[LDt1{:(360)403-3417 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:4008 174th Place NE Permit#:440 Parcel#:00934700001500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:NELSON WALTER A&BARBARA L Name: Brennan Heating Name:Brennan Heating Address:4008 174TH PL NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223-3705 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#:BRENNHA97IR9 EXP: 12/29/2015 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: 1 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI 10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City 1'Ar ton must be o ted on your sales tax return fptm and coded City of Arlington#3101. 'lTl/l / Signature Print Name Date Released By Date CONDITIONS Requirements: 3" Concrete pad with seismic bracing attached to pad. Provide electrical disconnect. Lines shall be insulated and adhesive tapes are not permitted. C403.2.8.1 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/4/2014 Mechanical Fee(Enter Fixture Fee) $25.00 8/4/2014 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon C403.2.7.3.2 Medium-pressure duct systems. C403.2.8 Piping insulation.All piping serving as part All ducts and plenums designed to operate at a of a heating or cooling system shall be thermally static pressure greater than 2 inches water gauge insulated in accordance with Table C403.2.8. (w.g.)(500 Pa)but less than 3 inches w.g.(750 Exceptions: Pa)shall be insulated and sealed in accordance 1. Factory-installed piping within HVAC with Section C403.2.7.Pressure classifications specific to the duct system shall be clearly equipment tested and rated in accordance with a test procedure referenced by this code. indicated on the construction documents in accordance with the International Mechanical 2. Factory-installed piping within room fan-coils Code. and unit ventilators tested and rated according to AHRI 440(except that the sampling and C403.2.7.3.3 High-pressure duct systems.Ducts variation provisions of Section 6.5 shall not designed to operate at static pressures in excess of apply)and 840,respectively. 3 inches water gauge(w.g.)(750 Pa)shall be 3. Piping that conveys fluids that have a design insulated and sealed in accordance with Section C403.2.7. In addition,ducts and plenums shall be operating temperature range between 60°F leak-tested in accordance with the SMACNA (15°C)and 105°F(41°C). HVACA ir Duct Leakage Test Manual with the 4. Piping that conveys fluids that have not been rate of air leakage(CL)less than or equal to 6.0 as heated or cooled through the use of fossil determined in accordance with Equation C4-5. fuels or electric power. CL = RP0.65 (Equation C4-5) 5. Strainers,control valves,and balancing valves associated with piping 1 inch(25 mm) Where: or less in diameter. F = The measured leakage rate in cfm per 6. Direct buried piping that conveys fluids at or 100 square feet of duct surface. below 60°F(151C). P = The static pressure of the test. C403.2.8.1 Protection of piping insulation.Piping Documentation shall be furnished by the insulation exposed to weather shall be protected designer demonstrating that representative from damage,including that due to sunlight, sections totaling at least 25 percent of the duct moisture,equipment maintenance and wind,and area have been tested and that all tested sections shall provide shielding from solar radiation that can meet the requirements of this section. cause degradation of the material.Adhesives tape shall not be permitted. TABLE C403.2.8 MINIMUM PIPE INSULATION THICKNESS thickness in Inches)' FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE(inches) TEMPERATURE RANGE AND USAGE Conductivity n Mean Rating Temperature, <1 1 to 1-1/2 to 4 to<8 ?8 (IF) Btu•in./(h•ft'•-F) -F <1-1/2 <4 >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 a. For piping smaller than 11/2 inch(38 mm)and located in partitions within conditioned spaces,reduction of these thicknesses by 1 inch(25 mm)shall be permitted(before thickness adjustment required in footnote b)but not to a thickness less than 1 inch(25 mm). b. For insulation outside the stated conductivity range,the minimum thickness(T)shall be determined as follows: T=r1(1+t/r)K&--1) where: T=minimum insulation thickness, r=actual outside radius of pipe, t=insulation thickness listed in the table for applicable fluid temperature and pipe size, K=conductivity of alternate material at mean rating temperature indicated for the applicable fluid temperature(Btu x in/h x ft2 x'F)and k=the upper value of the conductivity range listed in the table for the applicable fluid temperature. C. For direct-buried heating and hot water system piping,reduction of these thicknesses by 11/2 inches(38 mm)shall be permitted(before thickness adjustment required in footnote b but not to thicknesses less than 1 inch(25 mm). CE-60 2012 Washington State Energy Code RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION 1S TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:_ MR I:]A_\-� --V�_ )a Project Description: In D, — �&n ad Owner: Address: Phone: �J�p �J�q �JoZ 1p Email: -� Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-790 Jaimie@brennanheating.com @brennanheating.com Applicant Signatur Electronic Signature if submitting on-line I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12/29/aD/ Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY Permit#: Accepted by: Date: RESIDENTIAL MECHANICAL %P PERMIT APPLICATION Department of Community&Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances ca c� r SPECIFICATIONS General Model No. XC17-024 XC17-030 XC17-036 XC17-042 XC17-048 XC17-060 Data Nominal Tonnage 2 2.5 3 3.5 4 5 Connections Liquid line(o.d.)-in. 3/8 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line(o.d.)-in. 3/4 3/4 7/8 7/8 7/8 1-1/8 Refrigerant 'R-410A charge furnished 7 lbs.14 oz. 8 Ibs. 0 oz. 7 lbs. 12 oz. 7 lbs. 14 oz. 12 lbs. 12 oz. 12 lbs. 14 oz. Outdoor Net face Outer coil 23.25 27.21 27.21 27.21 27.21 27.21 Coil area-sq.ft. Inner coil --- --- --- 26.36 26.36 Tube diameter-in. 5/16 5/16 5/16 5116 5116 5/16 No.of rows 1 1 1 1 2 2 Fins per inch 26 26 26 26 22 22 Outdoor Diameter-in. 26 26 26 26 26 26 Fan No.of blades 5 5 5 5 5 5 Motor hp 1/3 1/3 1/3 1/3 1/3 1/3 Cfm 2650 3055 4025 4025 4230 4230 Rpm 400 450 600 600 675 675 Watts 37 53 122 122 185 185 Shipping Data-lbs. 1 pkg. 263 285 286 311 344 349 ELECTRICAL DATA Line voltage data-60hz-1 ph 208/230V 208/230V 208/230V 208/230V 2081230V 208/230V 2 Maximum overcurrent protection(amps) 30 30 30 40 50 50 s Minimum circuit ampacity 20.0 20.0 20.0 24.4 29.3 33.3 Compressor Rated load amps 13.5 12.8 14.1 17.9 21.8 25.0 Locked rotor amps 58.3 64.0 77.0 1 77.0 117.0 134.0 Power factor .97 .98 .98 .93 .96 .98 Outdoor Fan Motor Full load amps 2 2 2 2 2 2 CONTROLS iComfort Wi-Fig'Thermostat 1 OF81 3 Remote Outdoor Temperature Sensor X2658 • (for dual fuel and Humiditrole) "Discharge Air Temperature Sensor 88K38 ComfortSense®7000 Thermostat Y0349 , Outdoor Temperature Sensor-for X2658 ComfortSense 7000 Thermostat OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Hard Start Kit 88M91 Freezestat 3/8 in.tubing 93G35 , 5/8 in.tubing 5OA93 Indoor Blower Off Delay Relay 58M81 , s Low Ambient Kit 68M04 Refrigerant L15-41-20 L15-41-40 Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 L15-65-50 Field Fabricate NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge sufficient for 15 ft.length of refrigerant lines. HACR type breaker or fuse. 'Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 'Remote Outdoor Sensor may be used with an iComforVl-enabled outdoor unit for a secondary(altemate)sensor reading.Sensor may also be used with a conventional outdoor unit. "Optional for service diagnostics. Freezestat is recommended with Low Ambient Kit. XC17-2 to 5 Ton Air Conditioner/Page 11 Permit#: 440 Permit Date: 08/04/14 Permit Type: RESIDENTIAL MECHANICAL Project Name: Nelson Applicant Name: Brennan Heating Applicant Address: 4601 S 134th Place Applicant, City, State, Zip: Seattle,WA 98168 Contact: Jaimie How Phone: 206-248-7900 Email:jaimie@brennanheating.com Scope of Work: Install 2-ton AC Unit Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 08/05/2014 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00934700001500 4008 174TH PL NE NELSON WALTER 111 Single Family A&BARBARA L Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866 CONTRACTOR Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor and BRENNHA971R9 CONTRACTOR Industries Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 08/04/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/05/2014 Brennan Heating 51187419 cc $50.00 Outstanding Balance $0.00 Notes Date Note Created By: 08/04/2014 Up to 18 SEER Launa Black Uploaded Files Date File Name 08/05/2014 440 bnelsonsignedpermit.pdf 08/04/2014 bnelsonmechappspecssiteplan.pdf