HomeMy WebLinkAbout17731 83rd Dr Ne_BLD377_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360)403-3551 BUILDING PERMIT Address:17731 83rd Drive NE Permit#:377 Parcel#:00958500005300 Valuation:0 00 OWNER APPLICANT CONTRACTOR Name:BOYNAN THOMAS F SR&THOMAS F Name:BoNs Heating&A/C Inc. Name:BOB'S HEATING JR Address: 17731 83RD DR NE Address:14148 NE 190th Street Address: 14148 NE 190th St City,State Zip:ARLINGTON.WA 98223-4038 City,State Zip:Woodinville,WA 98072 City,State Zip:Woodinville,WA 98072 Phone: Phone:206-378-6723 Phone:206-378-6723 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BOB'S HEATING Name: Address: 14148 NE 190th Street Address: City,State,Zip:Woodinville,WA 98072 City,State,Zip Phone:206-378-6723 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: CONST TYPF. DWELLING UNITS: 1 OCC GROUP: BUILDINGS: ] OCC LOAD: PERMIT APPROVAL l AGREE rO COMM Y WITII CITY AND STATE LAWS Rl:(il il_A FIND CONSTRIX"PION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATI'OF WAS14INGTON RELATING TO WORKMEMS COMPENSATION INSURANCE AND RC W 18,27. TIIIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPtMY AND ALL FEES ARE PAID IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI l0 SALES TAX NOTICE::Sales lax relating to construction and construction materials in the City of Arlington uu •r medon%unr sales tax return ronn and coded ity of Arlington#3101 Signature Print Name a Rtk •d By Date CONDITIONS Requirements: 3" concrete pad with seismic bracing attached to pad;lines must be insulated and the use of adhesive tapes are not permitted. See attached(C403.2.8.1)Adhere to approved appliance. THIS PERMIT AUTI IORIZS ONLY THE WORK NOTED THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC)WILL REQUIRE SEPARATE PERMISSION PERMM FEES Date Description Fee Amount 5/22/2014 Mechanical Fee(Enter Fixture Fee) $25 00 5/22/2014 Mechanical Permit Base Fee $25 00 Total Due: 550.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 - —When calling for an inspection please leave the following information: i CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17731 83rd Drive NE Permit#:377 Parcel#:00958500005300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BOYNAN THOMAS F SR&THOMAS F Name: Bob's Heating&A/C Inc. Name:BOB'S HEATING JR Address: 17731 83RD DR NE Address:14148 NE 190th Street Address: 14148 NE 190th St City,State Zip:ARLINGTON,WA 98223-4039 City,State Zip:Woodinville,WA 98072 City,State Zip:Woodinville,WA 98072 Phone: Phone:206-378-6723 Phone:206-378-6723 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BOB'S HEATING Name: Address: 14148 NE 190th Street Address: City,State,Zip:Woodinville,WA 98072 City,State,Zip Phone:206-378-6723 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THF.WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington Qnu -reported on your sales tax return form and coded City of Arlington#3101. - r Signature Print Name Date Rel-a ed By Date CONDITIONS Requirements: 3" concrete pad with seismic bracing attached to pad; lines must be insulated and the use of adhesive tapes are not permitted. See attached (C403.2.8.1) Adhere to approved appliance. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/22/2014 Mechanical Fee (Enter Fixture Fee) $25.00 5/22/2014 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0 00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �C-XPa y RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community Development City of Arlington• 238 N Olympic Ave. •Arlington,WA 98223 •Phone(360)403 3551 •FAX(360)403 3418 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS, TWO(2)SETS OF SPECIFICATION SHEETS AND TWO(2) SETS OF WASHINGTON STATE ENERGY CODE(if applicable). Project Valuation: 5100 Project Address:17731 83rd Dr NE Parcel ID#: 00958500005300 Lot#: Subdivision: Project Description: add ac to existing hvac system Owner: Tom Boynon Phone Number: (360)474-9733 Address: 17731 83rd Dr NE City:Arlington State: Wa Zip Code:98223 Contact Person:James Gosnell Phone Number: 206-378-6723 Cell Phone: Fax: E-mail: jgosnell@bobsheating.com Address: 14148 NE 190th St City:Woodinville State: wa Zip Code:98072 Please List quantity of fixtures below: FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS FURNACE OVER 100K FLOOR FURNACE SUSPENDED HTR/UNIT HTR BOILER UP TO 3 HP APPLIANCE REPAIR SOLID-FUEL APPLIANCE BOILER UP TO 4-15 HP AIR HANDLING UP TO 10K CFM FIREPLACE INSERT BOILER UP TO 16-30 HP _ AIR HANDLING OVER 10K CFM VENTILATION SYSTEM HEAT PUMP VENTILATION FANS OTHER VENT HOOD _ DOMESTIC INCINERATOR ALL OTHER UNITS FREESTANDING STOVE Contractor: Bob's Heating Phone Number: BOIL-840-3346 Address: 14148 NE 190th St City:Woodinville State: wA Zip Code:98072 Contractor's License Number:BOBSHHA9790B Expiration:9/3/2015 hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described pr arty will be in accordance with the laws,rules and regulation of the State of Washington. Applicants nature Date' Print Applicants Name Re�e��ed FOR STAFF USE ONLY Permit# Arc pt y Amount Received Receipt# Date Received 1 2010 CJY I�•Y.: . tit. Property Owners Name: �.,,, _Assessor's parcel c�c»t s s`v�"� 7� Site Address: j) i t (7s ,t of Site Plan North Le end: -... property line Building perimeter Map Scale: I (in)=20' \i 4 r ;x) I I I j • 1\\ I i 700695-YTG-A-0312 Physical and Electrical Data MODEL YCJF16 YCJF24. YCJF30 YCJF36 YCJF42 YCJF48 CJF60 S41S1(E) S41S1(E) S41S1(E) S41S1(E) S41S1(E) S41S1(E) S41S1(E) 'Unit Supply Voltage 208-23oV,1d,60Hz (Normal Voltage Range t 187 to 252 Minimum Circuit Ampaaty 12.0 16.8 18.4 19.1 23.9 27.9 35.9 Max.Overcurrent Device Amps 2 20 25 30 30 40 45 60 Min.Overcurrent Device Amps 3 15 20 20 20 25 30 40 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load 9.0 122.8 14.1 14.1 17.9 21.1 27.5 Amps mocked Rotor 46 ',TSB 73 77 112 115 135 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No No No No Factory External Check Valve No No No No No No No HS Kit Required with TXV 4 No No No No No No No Fan Motor Amps RaiedLoad 0.8 9.8 0.8 1.5 1.5 1.5 1.5 (Fan Diameter Inches 22 22 22 22 24 24 24 Rated HP 1/8 1/8 118 1/4 114 1/4 114 Fan Motor Nominal RPM 1075 1075 1075 850 850 850 850 Nominal CFM 2750 z750 2800 3200 3600 3600 3700 Face Area Sq.Ft. 13.1 13.1 17.4 17.4 20.0 21.4 24.0 Coil Rows Deep 1 1 1 1 1 1 1 Fin/Inches 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/8 3/8 3/8 310 318 318 Vapor Line Set OD(Field Installed) 314 3/4 3/4 3/4 7/0 718 1 1/8 Unit Charge(Lbs.-Oz.)5 3-10 3-2 3-7 3-10 4-4 4-9 5-9 Charge Per Foot,Oz. 0.62 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 1 125 1 128 130 145 172 180 199 Models with"E"on the end of the model number have an EfectroRnO coating on the outdoor coil. 1. Rated In accordance with ANSI/AHRI Standard 110-2002,utilization range"A". 2_ Dual element fuses or HACR circuit breaker.Mapmum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 5. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit,and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in length multiplied by the per foot value. All dimensions are in inches.They are subject to change with- out notice.Certified dimensions will be provided upon request. C Dimensions Refrigerant Connection Unit (Inches) Service Valve Size Model Al B I C Liquid Vapor 18 28 29 29 24 28 29 29 A 30 36 29 29 3/4" 36 36 29 29 3/8" 42 34 33.6 33.6 4t$ 36 33.6 33.6 60 40 33.6 33.6 8 1. Including Fan Guard. 2. Adapter fitt ng required for 1-118"line set. 2 �4, / Johnson Controls Unitary Products �j cT>%ay RESIDENTIAL MECHANICAL 4P PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington,WA 98223 • Phone (360)403 3551 •FAX(360)403 3418 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS, TWO(2) SETS OF SPECIFICATION SHEETS AND TWO(2) SETS OF WASHINGTON STATE ENERGY CODE(if applicable). Project Valuation: 5100 Project Address:17731 83rd Dr NE Parcel lD#: 00958500005300 Lot#: Subdivision: Project Description: add ac to existing hvac system Owner: Tom Boynon Phone Number: (360)474-9733 Address: 17731 83rd Dr NE City:Arlington State: Wa Zip Code:98223 Contact Person:James Gosnell Phone Number: 206-378-6723 Cell Phone: Fax: E-mail: igosnell@bobsheating.com Address: 14148 NE 190th St City:Woodinville State: wa Zip Code:98072 Please List quantity of fixtures below: FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS FURNACE OVER 100K FLOOR FURNACE SUSPENDED HTR/UNIT HTR BOILER UP TO 3 HP APPLIANCE REPAIR SOLID-FUEL APPLIANCE BOILER UP TO 4-15 HP AIR HANDLING UP TO 10K CFM FIREPLACE INSERT BOILER UP TO 16-30 HP AIR HANDLING OVER 10K CFM VENTILATION SYSTEM HEAT PUMP VENTILATION FANS OTHER VENT HOOD DOMESTIC INCINERATOR ALL OTHER UNITS FREESTANDING STOVE Contractor: Bob's Heating Phone Number: 800-840-3346 Address: 14148 NE 190th St City:Woodinville State: wn Zip Code:98072 Contractor's License Number:BOBSHHA97908 Expiration:9/3/2015 1 hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described pr erty will be in accordance with the laws,rules and regulation of the State of Washington. Applicants nature Date t��Ize // Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 2010 CJY Permit#: 377 Permit Date: 05/22/14 Permit Type: RESIDENTIAL MECHANICAL Project Name: Boynon Applicant Name: Bob's Heating &A/C Inc. Applicant Address: 14148 NE 190th Street Applicant, City, State, Zip: Woodinville, WA 98072 Contact: James Gosnell Phone: 206-378-6723 Email:jgosnell@bobsheating.com Scope of Work: Add A/C to existing hvac system Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/06/2014 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning BOYNAN 00958500005300 17731 83RD DR NE THOMAS F SR& Residence Single Family -Detached THOMAS F JR Contractors Contractor Primary Contact Phone Address Contractor Type License License# BOB'S HEATING Lucinda 206-378-6723 14148 NE 190th CONSTRUCTION Labor&BOBSHI-A853NQ Honeycutt St CONTRACTOR Industries BOB'S HEATING Lucinda 206-378-6723 14148 NE 190th CONSTRUCTION COA 603 522 028 Honeycutt St CONTRACTOR Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 05/22/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/06/2014 James Gosnell 50540032 cc $50.00 Outstanding Balance $0.00 Notes Date Note Created By: 05/22/2014 Do not issue until Business License has been issued.1p Launa Black 05/22/2014 SEER 14.5 Launa Black Uploaded Files Date File Name 06/13/2014 17731 83rd.docx 05/22/2014 Application(28).pdf 05/22/2014 YCJF specs.pdf 05/22/2014 site plan(3),pdf Property Owners Name: C N ei V, Assessor's parcel Site Address: I �3 t r .t �r At, Site Plan North L_Legend: i ---- property line ` Building perimeter 14 Map Scale: I"(in)=20' P P t t 700695-YTG-A-0312 Physical and Electrical Data MODEL YCJF18 YCJF24 YCJF30 YCJF36 YCJF42 YCJF48 YCJF60 S41S1(E) S41S1(E) S41S1(E) S41S1(E) I S41S1(E) S41S1(E) S41S1(E) Unit Supply Voltage 208-230V,10,60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 12.0 16.8 18.4 19.1 23.9 27.9 35.9 Max.Overcurrent Device Amps 2 20 25 30 30 40 45 60 Min.Overcurrent Device Amps 315 20 20 20 25 30 40 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load 9.0 12.8 14.1 14.1 17.9 21.1 27.5 Amps Locked Rotor 46 58 73 77 112 115 135 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No No No No Factory External Check Valve No No No No No No No HS Kit Required with TXV No No No No No No No Fan Motor Amps I Rated Load 0.8 0.8 0.8 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 22 24 24 24 Rated HP 1/8 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor Nominal RPM 1075 1075 1075 850 850 850 850 Nominal CFM 2750 2750 2800 3200 3600 3600 3700 Face Area Sq.Ft. 13.1 13.1 17.4 17.4 20.0 21.4 24.0 Coil Rows Deep 1 1 1 1 1 1 1 Fin/Inches 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed) 314 3/4 314 3/4 7/8 7/8 1 1/8 Unit Charge(Lbs.-Oz.) 3-10 3-2 3-7 3-10 4-4 4-9 5-9 Charge Per Foot,Oz. 0.62 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 125 128 130 145 172 180 199 Models with"E"on the and of the model number have an ElectroFlndD coating on the outdoor coil. 1. Rated In accordance with ANSI/AHRI Standard 110-2002,utilization range"A". 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 5. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit,and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difrerenoo in longth multiplied by the per foot value. All dimensions are in inches. They are subject to change with- out notice.Certified dimensions will be provided upon request. C Dimensions Refrigerant Connection Unit (Inches) Service Valve Size Model At B I C Liquid Vapor 18 28 29 29 24 28 29 29 A 30 36 29 49 3/4" 36 36 29 29 3/8" 42 34 33.6 33.6 7/8" 48 36 33.6 33.6 60 40 33.6 33.6 7/8"2 t !3 1..Including Fan Guard. �- 2. Adapter fitting required for 1-1/8"line set. 2 Johnson Controls Unitary Products