Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20227 77th Avenue NE_BLD1631_2026
V FIRE ALARM PERMIT APPLICATION Department of Community &Economic Development City of Arlington• 18204 59th Ave NE•WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓� New Fire Alarm Fire Alarm Alteration/Addition Project Address 77TH AVE NE BUILDING(8V q Parcel ID#: 00829100000103 Number of Zones/Panels:l BuildingArea S Ft 9000 3500.00 q ): Valuation: Owner: WD ARLINGTON INVESTMENTS LLC Phone Number.- 425 750 7926 Address: 1020 W. CASINO ROAD City:EVERETT State:WA Zip Code:98204 Contact Person:-DAVID MOW Phone Number:425 290 9600 Cell Phone: 425 290 9600 Email: DAVID@FPISEATTLE.COM Address: 1730 GIBSON ROAD EVERETT WA 98204 City: State: Zip Code: Contractor: FIRE PROTECTION INC 425 290 9600 Phone Number: Address: 1730 GIBSON ROAD EVERETT WA 98204 City: State: Zip Code: Contractor's License Number-FIREPI*021ML 7/31/2018 Expiration: Contact Person: DAVID MOW Email: DAVID@FPISEATTLE.COM Electrical C ntractor: FIRE PROTECTION INC 425 290 9600 1f30 GIBSON ROAD Phone Number: Address' W'4 EVERETT 98204 City: State: Zip Code: Contractor's License Number:FIREPI*021ML 7/31/2018 Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property with the laws,rules and regulations of the State of Washington. 08/02/2017 DAVID MOW Applicants Signature Date Print Applicants Name FOR STAFF USE ONLY __ SEP 06 2017 Permit# Accepted BV Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/1 6 P CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:20227 77th Ave NE,Bldg.M Permit#:1631 Parcel#:00829100000103 Valuation:3500.00 OWNER APPLICANT CONTRACTOR Name:WD ARLINGTON INVESTMENT LLC Name:Fire Protection,Inc. Name:FIRE PROTECTION INC Address: 1020 WEST CASINO RD Address:1730 Gibson Road Address: 1730 Gibson Rd City,State Zip:EVERETT,WA 98204 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98204 Phone: Phone:425-290-9600 Phone:425-290-9600 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be rc ed on your sales tax return form and e C' bf Sig inl Name Dal/ Released By y e CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/26/2017 Fire Alarm Fee $88.90 9/26/2017 Fire Review Fee $100.00 9/26/2017 Processinglrechnology Fee $25.00 Total Due: $213.90 Total Payment: $0.00 Balance Due: $213.90 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX (4251353-4546 8/1/2017 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17 . The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17 . Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72 , 2013 edition requirements as well as WAC, IBC, IFC 2012 , NEC current and your additional requirements . The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals . Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards . Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS . A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements . A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE Park 77 Apartments *Building 8* 20201 77th Ave Ne Arlington , WA APPROVED UL MONITORING COMPANY Alarm Center, Inc. /FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds . Low air shall activate at 25lbs, causing for a supervisory signal . A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal . Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET-3 #120904 CITY OF REDMOND D.O.R. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BUILDINGS LOCATED IN BUILDING 17 @POTTER P 3 00 P/uS Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp each _ • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design '' • 1000 Event History Buffer V` i NYC Fire Dept. Certificate of Approval Potter/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a 5 year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY-5 relay module,SPG-1000 serial parallel gateway and DRV-50 Description LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(1/0)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The 1/0 may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the intemet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the LTD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'�O�IUsJ w. #8830035-REV A PAGE 1 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignal.com P"�O�A'SP v #8830035-REV A PAGE 2 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal enclosure. The Potter/Nohmi protocol is a digital protocol with a proven design for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T-Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSUUL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P100 and P200. CA-6075—Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RLy--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a serial or parallel printer The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 maybe installed in the t stacker bracket or ordered with the optional rack mount enclosure.o allow manipulation of the Menu on board the panel.The panel is shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the Internet,the panel may be selectively programmed to • Trouble-Amber e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'��PlusZ* w. #8830035-REV A PAGE 3 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel Specifications 18.91" 17.60" Electrical Specs:AC Mains O O TOP o 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.41" 3.75" DEPTH Battery p 0 130 mA Standby 220mA Alarm b • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated a • 1 Amp per I/O circuit,regulated �e c7 O • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2) 18AH batteries LEFT SIDE RIGHT SIDE Cabinet • 16 gauge cold rolled steel with removable BOTTOM ` locked door • Dimensions—18 15/16"W x 27 5/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120'(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/- 10°F(25°C+/-5°C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 0 Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) 0 Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) 0 Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'h�T PUF'J w. #8830035-REV A PAGE 4 OF 4 08/12 POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F) 10%-93% @ 30°C(86°F)non-condensing 0 © humidity Maximum Wire Length 6500 FT ® 0 Maximum Annunciators 31 Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters Product includes 5 year warranty U� LISTED S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character, 16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. , It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Instal!inac!cord!anc!e with compatib7fir,alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator 4CA-60775 + m + a P-LINK + a + A B + + + + Panel + + + + + + Panel + + Connection Remote -LIN + Annunciator Connection + Remote -LIN< Annunciator m Q m Oa O a + Q O Remote O Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5406077-REV B-1 PAGE 1 OF 2 9/11 (E) POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) O ❑ 0 0 OWWWW .-9. O 0 © A on ® 9 ® + Al O o Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV 13-1 PAGE 2 OF 2 9/11 CPOTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel • Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. ©POTTER PSN-1000 Compatible with all Potter PFC-6000 series fire alarm control panels. Ine Srnool of Prowon P"W supply Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA & 0L—j S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830032-REV B PAGE 1 OF 2 09/14 (E) POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER 18.91" 17.60" 4 0 0 TOP w 0 4.41" 3.75" DEPTH O O 0 0 0 N O O O 0 LEFT SIDE RIGHT SIDE BOTTOM Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.#8830032-REV B PAGE 2 OF 2 09/14 SYSTEM SENSOR MIF Photoelectric Smoke Detectors —277�y *Poll' System Sensor i3-series smoke detectors represent '010 b significant advancement in conventional detection.The i3 family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installerto pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- indicated maintenance and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. T istin s M MEA MSFMTPROVED approved approved cC I,us I W6 7272-1653:152 290-01-_ __., 313C93? (-L3)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 uA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 1207(0°C to 49°C);2WT-B and 4WT-B:327 to 1007(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 1357(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:417(5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box flinch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter f_ SY TE� m2cha system Sensor. �/ 3825 Ohio Avenue•St.Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09 latest version okhis data sheet. A06-0318-007.6/09•#2169 P POTT ERS A ka-"Wl' DCM-4 ® The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box s- s. • Wiring terminals accessible when mounted in box ©�®M-�++•■.+a • All wiring terminals accept 22 to 14 AWG • Product includes a 5 year warranty tom• . �� NOTE: This addressable module does not support 2-wire smoke f z2 c2 zi ;, ci detectors. Stock Number: 1430822 LISTED �zw� S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC I 100 S2 Max Wiring Cpacitance of IDC 1 µF EOL Resistor 5.lK S2 Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L X 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W X 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 P POTT ERS OHM/® DCM-4 ® The Symbol of Protection Dual Contact Module Setting the Address Each addressable module, smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box O e ° ° o e Wiring Diagrams DCM-4 With One Class ACircuit NOl FROM FACP OR C 1 PREVIOUS MODULE S+ ZI S- NO2 TO THE NEXT MODULE F 1 C2 SELECT STYLE D 0000 LED Q Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4 With Two Class B Circuits NOl FROM FACP OR C 1 PREVIOUS MODULE S+ Zl "OHM1/2W S- NO2 TO THE NEXT MODULE ppH1pC2 �000 LED O Z2 SELECT STYLE B 5.1K OHM 1/2W Potter Electric Signal Company,LLC St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignal.com :so 9001:2008 1 DESIGNING,MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL 1llOWN PULL DOWN . 10 Amp Snap Action Switch Gold plated SPST contacts prOrrER 0 • Optional auxiliary contacts • Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod eus FMo &�5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-1T.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: I Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL 1llOWN PULL DOWN . 10 Amp Snap Action Switch Gold plated SPST contacts prOrrER 0 • Optional auxiliary contacts • Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod eus FMo &�5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-1T.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: I Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24 V D C The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R I E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide°feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate°- Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features � • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C&uS :U0= O Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSI/UL 464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module • CSFM: Pending • Checkmate°-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBC/IFC/IRC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: �i •j ' = R=Red Faceplate MEMBER •� GHLFW 904-0530-002 24 VDC W=White Faceplate ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max. Horn Mode Operating Operating Operating Operating ANSI/UL 464 ANSI/UL 464 Current Current Current Current Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Temporal 3 520 Hz I 77.8 dBA 1 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4 520 Hz*1 81.5 dBA 1 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA O Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32 to 120 F(0 to 49 C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSUUL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSUUL average RMS method. ANSUUL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC S E R I E NOTES: UL Listed • THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal Signal PULSING SIGNALING CIRCUITS Panel S+ s- s- H+ H- S+ s+ s- H+ H- • THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised 0 0 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE 1 + ENO LINE • SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. S GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-436-8391. DOIMIW x o Lt LOCKING 0 0 o SCREW 0 " (optional) Cho H+ logo RED WIRES �- H! Q BLACK WIRES 6- � O o H- U a O o 00 NORMAL-LOUD o c �`f/ DECIBEL JUMPER. 0 0 FOR LOUD DECIBEL CEED INSTALL JUMPER. SLIDE ONTO BRACK Gentex Checkmate® Gentex Super-Slide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE:CARE SHOULD BE TAKEN TO NOT qM SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important Notice: GHLF-01 GENTEX These materials have been prepared Gentex Corporation Gentex')for informational purposes only,are O necessarily summary,and are not purported to serve as legall advice and should not used s such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each persons activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. CPOTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input voltage Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x I I 0.5"(1.27 cm)deep I Jumper selectable temporal 3 or continuous tone V Horn frequency is 3100Hz • Terminal blocks(12 AWG to 18 AWG) • Low current consumption • Variety of mounting options for new construction and retrofit E applications • Synchronize using the AVSM Series control module • ANSUUL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 320 to 120OF(00 to 49°C) 4890001 MHT-1224R R=Red facepalte 4890002 MHT-1224W W=Off-White faceplate 4890003 MHT-1224PR P=Plain 4890004 MHT-1224PW SIGNALING U� LISTED Product includes a 5 year warranty Description The MHT-1224 Series mini-horn is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT-1224 is ideal for applications where a dependable audible is ANSUUL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm horns shall be Potter model MHT-1224.The appliance shall be listed with Underwriters Laboratories(ANSUUL)for use with fire protective signaling systems(ANSUUL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830065-REV A PAGE 1 OF 2 06/13 (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1221 MHT-I I 1151I I; WIRING DIAGRAM FOR DUAL CLASS B CIRCUITS WITH A SINGLE AVS"CONTROL MODULE CONTROI PANtI + — + SYNCODULAl10N F A C P MUrAIIE 1MT•t7H ANT•t!N h• lu M SIJI>f kV F.I 'NU IT I INr SIGnn•. tE51STDR CIRI'I ' EOI R SIGNAL CIRCUITS wr-Tti+ rrtfar 1_4Cf< B:-ALK Et,-ACK BLAf,R a., Wiring Diagram EOLR Mini-Horn Wiring Use a screwdriver to break the jumper for a continuous tone. O DO NOT BREAK m JUMPER IF TEMPORAL 3 TONE IS NEEDED. Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT-1224 Current Ratings feet per ANSI/UL feet per ANSFUL feet per ANSI/UL 464 Room dBA @ I 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. 24 VDC UL Max 18 mA Temporal 3 81 dBA 78 dBA 78-86 90 12 VDC UL Max 13 mA Continuous 86 dBA 1 83 dBA 78-86 90 NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 RMS current ratings are per ANSFUL average RMS method.ANSFUL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSFUL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FAIR ratings,see installation manual. PRINTED IN USA MFG.#8830065-REV A PAGE 2 OF 2 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S O R I E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and P A G E outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan°- providing maximum visibility and reliability i • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x l •�, " 4.18" (10.62 cm) deep • 3/4"conduit knockouts l'llll� • Reinforcement steel hardware -- • Outdoor resistant gasket • Available in red or off-white GOE-R GOE-W GOELP OUTDOOR ENCLOSURE Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. ' Standard Features • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x 3.25" (8.255 �+- cm) deep • 3/4"conduit knockouts • Reinforcement steel hardware ' �- • Outdoor resistant gasket ' • Available in red or off-white GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage, the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications f ►� The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL •, 464 listed for use indoor and outdoor applications when used with the WSSPK Series speaker and speaker/strobe. « Gl Standard Features o' v • ANSI/UL 464 listed • 1/2"conduit knockouts with metal washer reinforcement L s • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.20" (15.75 cm) square x 2.04" (5.18 cm) deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white ACCESSORIES PAGE GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander' (GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2" conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57" (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT & AGENT BEZELS Applications The Gentex ALERT and AGENT bezels are constructed of durable plastic and is q fully compatible with the Commander (GE)and Commander' (GE3) Series horns, l strobes and horn/strobes. F Standard Features R T • Easy to install I • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander (GC) Series strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.2" (15.75 cm) round x 1.67" (4.24 cm) deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice: 551-0031-02 G E N T E X These materials have been prepared Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and arere not purported to servee as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws, CORPORATION regulations and rules. The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. S-24 & HS-24 CPOTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,& 110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module Prewire entire system,install mounting bracket,then install signals Documented lower installation and operating costs Al— Input terminals accept 12 to 18 AWG t ' Switch selection for high or low dBA Switch for chime,whoop,mechanical and 2400Hz tone Tamperproof re-entrant style grill F I I I I I I I I Switch for continuous or temporal 3 tone(not available on whoop tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 320F to 120OF(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/TJL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1 Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION 3 4 5 ®o Mechanical Temporal 3 ON ON ON �® 1, Mechanical-Continuous OFF ON ON 2400Hz-Temporal 3 ON OFF ON ® S+ 2400Hz-Continuous OFF OFF ON S- Chime-Temporal 3 ON ON OFF -® H+ � Chime-Continuous I OFF ON OFF Whoop I ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket Checkmate®Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most - measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. r- T Break off pin and insert l S into hole at the bottom of .a the selector to lock candela setting.Signal must be removed from bracket and pin pushed forward from backside out of hole to change candela. To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 2 OF 4 06/13 S-24 & HS-24 CF POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR I 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSFUL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal signal Panel Signal Signal g+ S+ S- H+ H- S+ S+ S- H+ H- s+ S+ S- H+ H- S+ S+ S- H+ H. Supervised Supervised 0 B 0 B Signal Circuit Signal Circuit \ + \ + END LINE END OF LINE RESISTOR RESISTOR \ + 7D END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 9 8 7 6 5 4 3 2 1 AIFPV DEVICE INSTALLATION REQUIREMENTS VICINITY MAP FIRE PROTECTION INC - Everett,)bWA 98204 auAcvrwr PARK 77 APARTMENTS425-290-9600 CEIUNG MOUv'D J. oInIA<a N01 PERMITTED SMOKE/HEATj� (MIN) HERE DAVID MOW DETECTOR C---- --A m AUDIO/NSUAL h NSUAL OEVCES 4• NOT pE PERMITTED ERMITTED M% � ^F 120904 r t[AE HERE BUILDING 8 T LEVEL III Safeway• o PERW HERE ERE D MCDoneld's IeRE F19E eevMan _ r� lrf.HIF.P MCHrtR 14'W PfiO\T UA.\'OBIT D t DFIRE ALARM _ "FPA%SH 14.1SW _ _ _ — 4.6'U LT H�-� ,-D o0 4 W - - OOOS05173 fe-AR ASAn Y'YI ifi-An LE MANUAL 0 �' l202017M ROY L CATS PULL ? Aerospace Ir A 'r llordleast QPOTEC, JAOt STATION dfadlvirl Tarn' QN FlNISNFD BOOR Ar uAK A R L I N G TO N, WA LL Nl y y NFPA' ^ CFPS #1473 INSTALLATION NOTES CITY OF REDMOND DAVIDc MO W Fire Alarm Symbol Legend 204TH STREET N.E. ��aais-B-141�� 1) Prior to calling for inspection;the installer shall provide SYMBOL DESCRIPTION PART NUMBER MFG QTY BACKBOX REQUIREMENTS MOUNTING REQUIREMENTS documentation to the local AHJ stating that the system has been ANN LCD REMOTE ANNUNCIATOR RA-8075 POTTER 1 n installed,tested,evaluated and confirmed to be in accordance with all LL governing codes and the approved plans.The Fire Alarm System PS INTELLIGENT IO AMP REMOTE POWER EXPANDER PSN-1000 POTTER 1 w � g g Pp P Y AREA OF WORK > installer shall complete an NFPA72 Record of Completion(NFPA72 S SPRINKLER TAMPER BY OTHERS BYOTHERS wN y 10.18.2.1.1). The completed Record of Completion shall be provided BUILDING 8 A W� a C �M DUAL INPUT CONTACT MODULE DCMA POTTER 1 BBOX-4,Standard beckbox,4 /„' l V O y to the AHJ inspector at the time of inspection(NFPA72 10.18.2.1.2.4). / B G.1 .� z=zZ; �P PULL STATION SINGLE ACTION P31-IT POTTER 1 BBOX-2,Standard backbox,2 48'AFF 2) Instructions for the operating,testing and maintenance of the 6SMOKE,PHOTO,2-WIRE 2W-B SYS SENSOR 1 BBOX-2,Standard backbox,2 o m>a N system,along with record drawings otherwise referred to as / g z o a, a ("as-built")and equipment specifications shall be provided at an cc 0 F LED,LF,HORN/STROBE,MC,wH LLFHsw WHEELOCK 9 BBOXA,Standard backbox,4 STAFFmo>mec?:o approved location(NFPA72 10.18.2.3). w o r`m> BLDG� m o=w r r ®aam STROBE,EXCEDER 24V M-C,WALL,WHITE STW W HEELOCK 7 BBOX-2,Standard backboX 2 BT AFF '�' J J z Q W F o w 3) All systems and devices shall be installed and tested per the = 11 a>IL a o manufactures listing and the authority having jurisdiction(NFPA72 b�mcv HORNISTROBE,EXCEDER24V,IWALL,WHITE HSW WHEELOCK 4 BBOX-2, STAFF i� / a) IIII(�1111 r outy a 10.14.2.1).Label all device locations containing EOL resistors. I I IQ BXLG 1 11�� Communit REVISION RECORD HORN LOW FREQUENCY,WH GHLFW GENTEX 15 BBOXA,Standard backbox,4 STAFF (BDildln _ DATE/DESCRIPTION 4)FACP&all Remote Power Supplies REQUIRE a DEDICATED _ 120VAC 20amp circuit.A notice placed in the FACP shall direct ❑H MINI HORN,wH MHT-lzzaw POTTER S BBOX-2,Standard backbox,2 STAFF DG O� - 1 personnel t0 the location Of the electrical panel that IS supplying p ; HORN/STROBE,2 WIRE,M-C,RED,WALL HS-24WR POTTER 1 BBOX-2,Standard backbox,2 STAFF DEDICATED power to the system(NFPA72,Section 10.5.5.1). The I r 1 @ DEDICATED circuit breaker that serves the fire alarm system shall be s WATERFLOW SWTICH BY OTHERS BY OTHERS BE _ (� �" I  a Labeled and Secured against tampering with a RED breaker lockout FACP FACP LOCATED N BUILDING n P3oD POTTER E N DG. SHEET LIST {� ., I ti (NFPA72,Section IIt I L p FA 0.0 FA DETAILS BL 5 OUTDOOR H(S WEATHERPROOF ENCLOSURE GOELP POTTER 1 LL I' FA 1.0 FIRE ALARM 5)This property will have one FACP located in the Community v U a) U FA 2.0 RISER/CALCS B Building.Each residential building will have a Remote Power Supply _ and a Remote Fire Alarm Annunciator connected to the main FACP in ,I — B the Community Building.The FACP will monitor each buildings fire sprinkler system via SEC,the occupant notification devices in each LLD LDG BL 3 L 'I the building will only activated when a fire alarm device from that — specific building(waterflow,smoke detector;pull-station) is r �� activated. 6) Wall mounted strobes shall be placed 80"minimum to 96" SYSTEM OUTPUTS SITE / PHASING PLAN SCALE 118"=1' maximum above floor level.(NFPA72 18.5.4.1 &2).Wall mounted R FlreSaferyConVol DATE: 8/1/17 Control Unit Annunciation strobes shall be sized in accordance with(NFPA72 Table 18.5.4.3.1(a). c PROJECT NAME Ceiling mounted strobes shall be placed and sized in accordance o o' with(NFPA72 Table 18.5.4.3.1(b). 7) When MORE than two notification appliances are visible at the W same time whether they are in the same room or adjacent space ,�z"&g;g` Z Z within the field of view,the flash of those strobes shall be y h P 4 y'`° CIRCUIT LINE TYPE Circuit Legend W W Q synchronized(NFPA72,Section 18.5.4.3.2(3)&(4). COo m Abbreviation T e Name 8) Pull stations shall be placed between 42 and 48 inches above floor Q��€q y�y o�� u U #1814 FPLR SLC-SIGNAL LINE CRKT ~ � Q Z level.Devices shall be red in color(ICC A117.1 309&NFPA 72 17.14.5 0 0 2,g° °a,a _Z = 0 c'"g �J A #16/4 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT Q F 04 y x. r390 a _ #1814 FPLR SBUS 9 Outdoor strobes required for approaching Emergency Vehicles to ea Z A ) q pp 9 9 Y QQc`r:A?ti et:o c t� � be located in the upper 25%of the building(at a serviceable height), SYSTEMINPUTS JAIBICID E F c H I J1 r J A and to be clearly visible from the emergency vehicle approach path. I Manual Fire Alarm Boxes ♦ ♦ ♦ ♦♦ 1 Y O 2 Smoke Detectors ♦ ♦ ♦ ♦♦ 2 N O Q 3 Watemow ♦ ♦ - ♦♦♦♦ 3 Fire Alarm Device Numbering 10)Fire Alarm circuits to be installed/secured/terminated in 4 Sprinkler Control Valve ♦ ♦ 4 N Q accordance with NEC,NFPA 72,IFC and Local AHJ requirements& 5 Fire Alarm AC Power Failure ♦ ♦ 5 (SLC)ADDRESSABLE DEVICES NOTIFICATION DEVICES a standards. 6 Fire Alarm System Low Battery ♦ ♦ 5 clRculr 7 Open Circuit ♦ ♦ 7 CIRCUIT 8 Ground Fault ♦ ♦ S F �DEVICE ADDRESS DEVICE# 11)The means of communication to the central stations for the fire 9 Notification Appliance Circuit Short ♦ ♦ 9 CANDELA alarm system is to be provided by a Potter UD-1000 DACT as per plan. 10 Remote Power Supply Trouble ♦ ♦ t0 sLC•#W System requires 2 x POTS telephone lines,1 of these lines is required A B c D E F G H I J S r� 1 SHEET DESCRIPTION to be DEDICATED to the FACP.The FACP is located in building 17. OPERATIONAL MATRIX SIG#-### j.� FIRE ALARM SMOKE DETECTOR SHOWN AS EXAMPLE DETAILS SHEET NUMBER FA 0.0 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC- 1730 Gibson Road Everett,WA.98204 425-290-9600 DAVID MOW ® v 120904, I LEVEL III D UNIT B-11 D SIGS-0� NFPA UNIT B-10 r--- 000805173 UNIT 84 Sgsma ( UNIT B-12 H r scsaas 1614 FPLR SIG 5 ROY L CATS N ---- i O PS IN RISER ROOM _�pPO�� I �P SIGS-0O] {T�}J w '— I I^ b�NFPA yyC' I I _ O CFPS CA slcnmt I STAIR/ TNR/ -.. I CITY OF REDMOND H A I ENTRY (� I I ENTRY DN s�cs-003 I a DAVID MOW I H #16-B-141co slo—o � sics.._ — --- sl s l (`� scao0z a w In �> W W t�et N V�Z a C O Q a',¢Oy S V tl K ppYaNJ 1 aO600a pEaw�LL rL, 3RD FLOOR N i p CO Owp rLm0 xwwarc 30wkuy gnLwugm¢ OOK.Ia REVISION RECORD 614 THHN SBUS TO THE FACP DATE/DESCRIPTION OCATED IN BUILDING 17 1614 FPLR SIG 3 — 612 THHN(SLC)TO THE FACP O PS IN RISER ROOM 6l4 FPLR SIG 2 OCATED IN BUILDING 17 PS IN RISER ROOM I— --- -0Ot ——————— F SHEET LIST ( I `" S umu°' '. FA 0.0 FA DETAILS - I 1 UNIT B-7 W4 E:lFA 1.0 FIRE ALARM I i iB I UNIT B-2 UNIT B3 I slc4-0m FA 2.0 RISER/CALLS UNITB-1 I Type Type I - - Ts FS'I UNITB-6 g TYpeA i 's O ---- — LL„�— UNITB-4 �, UNITB-6 sl—D ,-I H slG4ms , UNIT 88 ------ ----- w20s 30Cp I Type A J sl sic400s I I I ! A SIG2-004 H ------ — I I I 1614 FPLR SIG 4 f sly A JrO PS IN RISER ROOM ,sco — r-- --'t— — --- - -- ----• SCALE 1/8"=V SIM-= 1 1614FPLR SIG I o �� A I_ I DATE: 8/1/17 Sot» PS IN RISER ROOM '1- _ V L loco < —_� p _l (� I A I I PROJECT NAME I o o I � a btaar o0 o n I_ XX uo F b- —� IC o O I I- t sicza0e ❑ �o pscG �� sco IX I — -- a �' siGz I ) ❑ tuc STAIR/ f('� . 1 I STAIR/ I sc4mz ~ W s'G'-001 STAIR/ I I STAIR/ _ _ - „oco r + ../ ENTRY �- I/ I ENTRY slc4-0m Z Z ENTRY ENTRY A .1-04 J 1 I H F I H SIG40t1 UP -- r I --- W W a A �yy —� siG44tos I _Z = OCD LF ___ OCD 110fD ,tOGD A I r SKi1-011 i I Q Q O SIG°-0°4 SIG°-0OG 91G1-0OS sIG1-0°5 A I SIWUt2J LL ♦^ 11°CD SIG3905 A r ---- o WTI Y m o A J _ 4.�� . � o Q 1ST FLOOR N 2ND FLOORN - a N SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1 .0 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC- 1730 Gibson Road Everett,WA.98204 425-290-9600 DAVID MOW Battery Calculations for Panel:PS BUILDING 08 Pan No:PSN-1000-INTELLIGENT IO AMP REMOTE POWER EXPANDER Part No. ly. Description Standby Total Standby Alarm Total Alarm �v Panel Equipment PSN-1000 MB 1 10 AMP POWER EXPANDER MB 75.0000mA 75.000OMA 215.0000mA 215.0000mA Total Panel Slby 75.00OOmA Toth Panel Alarm 215.00OOmA 120904, Peripheral Devices LEVEL III 2W-B 1 SMOKE,PHOTO,2-WIRE(Initiating) 0.0100.4 0.0100mA 6.5000mA 6.5000.A P31-IT 1 PULL STATION SINGLE ACTION(Initiating) O.000OmA 0.0000mA 0.0000mA 0.0000mA D LLFHSW LED,LF,HORWSTROBE,MC,WH(Notification) O.000OmA 0.0000mA 292.0OOOmA 2628.00DOmA STW 7.STROBE,EXCEDER 24V M-C,WALL,WHITE(Notffi.b.n) 0.000OmA 0.0000.A 57.0000mA 399.0000mA HSW HORN/STROBE,EXCEDER 24V,M-C,WALL,WHITE(Notification) 0.000OmA 0.000OrtW 102.00OOmA 408.00OOmA !GHLFW 1 HORN LOW FREQUENCY,WH(Notification) O.000OmA O.000OmA 99A000mA 1590.4000mA D 4W MINI HORN,WH(Natifiwtion) O.000OmA O.o000mA 22.0000mA 176.00o0mA NFPA WR 11 HORN/STROBE,2 WIRE,M-C,RED,WALL(Notification) 0.000omA O.000OmA 186.0000mA 186.0000mA 000805173 Total Peripheral Stby 0.0100mA Total Periph Alarm 5393.9000rnA Total Standby Amps 75.0100mA Total Narm Ampsl 5608.9000mA ROYL CATS P�QpOTECl70y Standby lime:24n An e Alarm time:5 Min 0.467Ah w Battery requirement 2.268An "' a Compensatlan Factors-Standby:1.2 Alarm:1.2 Requirement with compensation: 2.121Ah boo NFPA yyC CFPS #1473 Circuit Calculations Panel:PS Card:00 Circuit:SIG1 Circuit Calculations Panel:PS Card:00 Circuit:SIG2 Circuit Calculations Panel:PS Card:00 CircuR:SIG3 Ciminal Voltage. SIG1 Terminal Name:e:20 enninWame:e:2 Circud Type:Notification Terminal Voltage:20.4V:DC Amperage:3.00OOA Cacutt Type:Notification Terminal Voltage:20 aV DC Amperage_3.0000A CircuftType:Nofification Terminal Voltage:20.4V:DC Amperage:3.0000A Cable.16I4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculatom based on Running Total Length. Calculations based on Running Total Length. Calculations based on Running Total Length. Design Criteria:Ambient temperature:167"1` Max.operating voltage drop:15% Design Crmena Ambient temperature'167°F Max-operating voltage bop:15% Design Criteria:Ambient temperature:16loF Max.operating voltage drop:l5% CITY OF REDMOND DAVID MOW Devicel Pad No I Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part Appliance Desc Distance Voltage N Current Volta a Volta D PSN-1000 Panel 20.4 PSN-1000 Panel 20.4 PSN-1000 Panel 20.4 na 416-B-141co 001 HSW HORNISTROBE,EXCEDER 24V,M-C,WALL,WHITE,30CD 3" 102.0000rtA 19.9E (0.4165V) 001 LLFHSW LED,LF,HORNISTROBE,MC,WH,110CD 48'- 292.00OOmA 19.8127 (0.5873V) 001 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,15CD 107 5T030OmA 19.310 (1.0893V) 002 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,15GD 2'-0 57.0000 19.9641 ((L0194V) 002 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,15CD 15'-0 57.o00DmA 19.672 (0.1407V) am HSW HORNISTROBE,EXCEDER 24V,M.C.WALL,WHITE,3000 21'-0 102.0000mA 19D981 (0.2126V) y 003 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,15CD 21'-0 57.0000 19.7725 (0.1916V) 003 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,15CD 17' 57.0000mA 19.5221 (0.15V) 003 STW STROBE,EXCEDER 24V M-C WALL,WHITE,15CO 18b 57.00OOmA 18.9521 (0.140V) w 004 LLFHSW LED,LF,HORNISTROBE,MC,WH,110CD 2'-0 292.0000mA 19.7554 (0.0171V) 004 HSW HORN/STROBE,EXCEDER 24V,M-C,WALL,WHITE,30CD 21'-0 102.00OOmA 19.3485 (0.17 5514 004 LLFHSW LED,LF,HORN/STROBE,MC,WH,110CD I" 292.0000 18.7 (0.1628V) m C 005 LLFHSW LED,LF,HORN/STROSE,MC,WH,110CD 26'-0 292.0000 19.6069 (0.14W 005 LLFHSW LED,LF HORNISTROBE,MC,WH,11 OCD T-0 2920000mA 19.2977 (0.0509V) 005 LLFHSW LED,LF,HORNISTROSE,MC,WH,110CD 4'-0 292.0000nA 18.7065 (0.0228V) 008 LLFHSW LED,LF HORNISTROBE,MC,WH,110CD 2'-0 292.0000 19.601 (0.0057V) 006 HSW HORN/STROBE,EXCEDER 24V,M-C,WALL,WHITE,30Cb 19'-0 102.00OOmA 19.2139 (0.0838V) 006 LLFHSW LED,LF,HORN/STROBE,MC,WH,110CD 14' 292.00OOMA 18.7265 (0.04V) cp W N y 92'-Gl 1092 0000mAl 00 LLFHS LED,LF,HORNISTROBE,MC,WH,110CD 4'-0 292.00OOmA 19.2002 (0.0137V) 176'-0 1092.0000n4 O e z m C Total clln r 1092.000OmA 006 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,15CD 29'-0 t 0000mAI 19-184 (0.0162V) Total Current 1092.0000mA Z#rA V N (Total VDrop Per®nt3.92%) Tow Voltage Drop:0.7988V 160'-0 1251.0000rrA (Total VDrop Percenl,8.20%) Total Voltage Drop,1.6735V 3 a V Total Curtent:1251.0000mA o d o aw (Total VDrop PerceM:526%) Total Voltage Drop,1.216V Ed j V aOwoopzouu'J a n2)w in as w,dO >w OMin Circuit Calculations Panel:PS Card:00 Clrcuit:SIG4 Circuit Calculations Panel:PS Card:00 Circuit:SIGS n up w a rc CircuftName:SIG4 CeaNName:SIG5 7�O w k u y Circuit Type:Notification Terminal Voltage:20.4VDC Amperage.3.Oo00A Circuit Type:Notification Terminal Voltage:20AVDC Amperage:3.0000A gn w u�tl C Cable.16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 V IY 'a- Calculations based on Running Total Length. Calculations based an Running Total Length. REVISION RECORD Design Criteria:Ambient temperature:1670F Maxc operating voltage drop_15% Design Criteria:Ambient temperature:167OF Max.operating voltage drop:15% DATE/DESCRIPTION Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Dro PSN-1000 Panel 20AV PSN-1000 Panel 20AV 001 GHLFW HORN LOW FREQUENCY,WH 44'-0 99.4000mA 19.8971 (0.5029V) 001 GHLFW HORN LOW FREQUENCY.WH 66'-0 99.4000mA 19.8941V (0.5059V) 1302 MHT-1224W MINI HORN,WH 5'-0 22AOO(mA 19s448V (0.0523V) 002 GHLFW HORN LOW FREQUENCY,WH IT-0 99.4000mA 19.8071V (0.087V) D03 HS-24WR HORN/STROBE,2 W02E,M-C,RED,WALL,11000 21'-0 1W.0000mA 19.6298V (0.2151V) 003 MHT-1224W MINI HORN,WH T-0 220000mA 19.71399V (0.0172V) 004 GHLFW HORN LOW FREQUENCY,WH 11'-0 99.4000mA 19.5371 (0.092OV) 004 GHLFW HORN LOW FREQUENCY,WH 36'-0 99.4000mA 19.5917V (0.1982V) SHEET LIST 005 GHLFW HORN LOW FREQUENCY,WH T-0 994000mA 195148 (00224V) 005 MHT-1224W MINI HORN,WH 31'-0 22.0OOOmA 19.4511 (0.1406V) 006 MHT 1224W MINI HORN,WH 56'-0 22.0000mA 19.152V (0.3926V) 006 GHLFW HORN LOW FREQUENCY,WH 5'-0 99.4000mA 19.4295V (0.0216V) FA 0.0 FA DETAILS 007 GHLFWj HORN LOW FREQUENCY,WH 5'-0 99.4000 iA 19A207 (0.0313V) 007 MHT-1224W MINI HORN,WH 3T-0 22.0000mA 19.3191V (0.1104V) FA 1.0 FIRE ALARM 008 GHLFW HORN LOW FREQUENCY,WH 32'-0 99.4000mA 18,9514V (0.1693V) 008 GHLFWj HORN LOW FREQUENCY,WH 6-0 99.4000mA 19.3034V (0.0157V) 009 MHT-1224W MINI HORN,WH 46'-0 22.0000mA 18.7527 (0.1987V) 009 GHIJMI HORN LOW FREQUENCY,WH 34'-0 9914000.A 19.23V (00734V) FA 2.0 RISER/CALLS 010 GHLFWHORN LOW FREQUENCY,WH 5'-0 99.4000mA 18,7322 (0.0205V) Ot0 DO W HORN LOW FREQUENCY,WH 14'-0 99.4000mA 19.2134V (0.0166V) B Oil GHLFWHORN LOW FREQUENCY,WH 42'-0 99.4000. 18.6007 (0.1315V) 011 MHT-1224W.MINI HORN,WH 4'-0 22.0000.A 19.2125V (0.0009V) 012 GHLFW HORN LOW FREQUENCY,WH 4'-0 99.4000mA 18.592V (0.0o86V) 244'-0 783.8000.A B 013 GHLFW HORN LOW FREQUENCY,WH 25'-0 99.4000mA 1B,5623 (0.0297V) Total Current:783.8000mA W4 MHT-1224W MINI HORN,WH T-0 22.0000mA 18.5617 (0.O006V) (Told VDrop Percer t5.82%) To.Voltage Drop:1.1875V 302'-0 1168.60DOmA Total Current:1168.6006mA (Total VDrop Percent9.01%) Total Voltage Dmp:L8383V SCALE: 1/8"=1' DATE: 8/1117 PROJECT NAME N LU H lF L,@F L,Fp LF l,Fy H LF V ~ Z pe H yP p' Sr H S H Ss LLI LLI 00 r� I- LF LF lF LF H l lF H@ L,Fy L,Fy tt� H LF L�J S aO Q � WA 9'pP 9�pP 9 SY � 55' 9' �£YW SCR >4R' [�54 F- r Y YY e m A QJIC� A Sam Waco noco ttoco ,ac0 Ism t` � r Z LF LF LF jx jx ti m r -j A 0 LL � O Q xm 30�o Q N ,sm tttxp 11oc0 tsm 15m 11oco a )x LF LF PS ry ,eco Ism artio BLDG 08 f 1taCD noc0 na0 1, SHEET DESCRIPTION h$ stir Ts FIRE ALARM a� �� RISER/CALCS FACP IN p� BUILDING 1 ANN SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 2 1 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 Go PHONE; (360)403-3551 BUILDING PERMIT Address:20227 77th Ave NE,Bldg.M Permit#:1631 Parcel#:00829100000103 Valuation:3500.00 OWNER APPLICANT CONTRACTOR Name:WD ARLINGTON INVESTMENT LLC Name:Fire Protection,Inc. Name:FIRE PROTECTION INC Address: 1020 WEST CASINO RD Address:1730 Gibson Road Address: 1730 Gibson Rd City,State Zip:EVERETT,WA 98204 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98204 Phone: Phone:425-290-9600 Phone:425-290-9600 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RC W 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION 14AS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC1I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be rep rted on your sales tax return form and Ct'Acls n I l Si rint Name Da Released By e CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 9/26/2017 Fire Alarm Fee $88.90 9/26/2017 Fire Review Fee $100.00 9/26/2017 Processing/Technology Fee $25.00 Total Due: $213.90 Total Payment: $0.00 Balance Due: $213.90 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon T Permit Information Date 9/6/2017 Permit Number 1631 Project Name Park 77 Applicant Name Fire Protection, Inc. Applicant Address 1730 Gibson Road City,State,Zip Everett,WA 98204 Contact David Mow Phone 425-290-9600 Email david@fpiseattle.com Permit Type Fire Alarm Site Address 20227 77th Ave NE, Bldg.M Valuation 3500.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 3 Proposed Use Mulit-Family Assigned To Kristin Foster Property Information Parcel#:00829100000103 Owner Information WD ARLINGTON INVESTMENT LLC WD ARLINGTON INVESTMENT LLC 20227 77th Avenue NE 1020 WEST CASINO RD ff EVERETT,WA 98204 Review Date T e Description Tar et Date Com feted Date 9/6/2017 Fire Alarm I1312017 Assi ned To Status Kevin Olander In Review Uploaded Files I _Upload File Date File 9/6/2017 11:19:44 AM 1631 Amlicationpdf Uploaded B 9/6/2017 10:48:34 AM 1631 Specs and Foster, Kristin Planspdf x Foster,Kristin x FIRE ALARM PERMIT APPLICATION lr�,G Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓ New Fire Alarm ❑ ❑ Fire Alarm Alteration/Addition Project Address:&^77TH AVE NE BUILDING(8 Parcel ID#: 00829100000103 Number of Zones/Panels:1 Building Area(Sq Ft): 9000 Valuation: 3500.00 -- Owner: WD ARLINGTON INVESTMENTS LLC 425 750 7926 Phone Number: Address: 1020 W. CASINO ROAD City:EVERETT State:W'4 Zip Code:98204 Contact Person:DAVID MOW 425 290 9600 Phone Number: Cell Phone: 425 290 9600 Email: DAVID@FPISEATTLE.COM Address: 1730 GIBSON ROAD EVERETT City: State:WA Zip Code: 98204 Contractor: FIRE PROTECTION INC 4252909600 Phone Number: Address: 1730 GIBSON ROAD EVERETT City: Slate: WA Zip Code:98204 Contractor's License Number FIREPPk021ML DAVID MOW 7/31/2018 Expiration-Contact Person: DAVID@FPISEATFLE.COM ---- ---- -- - Email: Electrical Contractor: FIRE PROTECTION INC 425 290 9600 1730 GIBSON ROAD Phone Number: Address: City: EVERETT State:WA Zip Code:98204 Contractor's License Number:FIREPI*021ML 7/31/2018 Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described roperty win t,P a�rnrrlanc@with the laws,rules and regulations of the State of Washington. 08/02/2017 DAVID MOW Applicants Signature Date Print Applicants Name FOR STAFF USE ONLY SEP 0 6 2017 Permit# ed BY Amount Received--- Re eit�r# — Date Received WEB Form-130 Page 1 of 1 6/16LP FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK,WA 98082 (4251290-9600 OR 1-800-681-1125 FAX 14251353.4546 8/1/2017 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17. The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17. Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72, 2013 edition. requirements as well as WAC, IBC, IFC 2012, NEC current and your additional requirements. The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards. Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS . A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. CITY OF ARLINGTON 1730 Gibson Rd. Everett, WA 98204 BUILDING DEPARTMENT WSCL# FIREPI*021ML UL CERT #608242-002 APPROVED JOB SITE NO CHANGES DATE BY Park 77 Apartments *Building 8* UNLESS APPROVED AUTHOR rTHE 20201 77th Ave Ne BUILDING INSPECTOR Arlington, WA Received OFFICE sEP o s 2017 F, D lV6l APPROVED UL MONITORING COMPANY Alarm Center, Inc. /FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AbMIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds . Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET=3 #120904 CITY OF REDMOND D.O.A. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BU7'--7 DINGS LOCATED T-7, BUILDING 17 (DPOTTER P300 P/US $9 Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp each • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design • 1000 Event History Buffer U NYC Fire Dept. 0 Certificate of Approval Potter/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a 5 year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY 5 relay module,SPG-1000 serial parallel gateway and DRV-50 O e s c r i p t i o n LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(1/0)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The I/O may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the intemet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the UD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO O POr.- EP.... 800-325-3936 • www.pattersignal.com +'k6,3F #8830035-REV A PAGE 1 OF 4 08/12 @POT T� � P300 PIUS � ' Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO ©►POMP.., 800-325-3936 • wwwpottersignal.com u'�1 #8830035-REV A PAGE 2 OF 4 08/12 P POTTER P300 PLUS J Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal The Potter/Nohmi protocol is a digital protocol with a proven design enclosure. for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T-Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSI/UL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P 100 and P200. C —Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RLy--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a The fire alarm control panel has a 4 x 40 LCD display to provide serial or parallel printer information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the to allow manipulation of the Menu on board the panel.The panel is stacker bracket or ordered with the optional rack mount enclosure. shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the Internet,the panel may be selectively programmed to • Trouble-Amber e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO ©POTTER 800-325-3936 • wwwpottersignal.com Plus;v #8830035-REV A PAGE 3 OF 4 08/]2 P POT P300 w PIUS� Fire Alarm Control Panel Specifications 1&9- Electrical Specs:AC Mains MP 0 O 0. 1 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.41- 175" DEPTH Battery O 130 mA Standby Q 220mA Alarm O • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated 8 d • 1 Amp per 1/0 circuit,regulated O 6 Q O O • Battery Charger range 8-55 Ah 0 Q • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2)18AH batteries LEFT SIDE NKMSIOE Cabinet • 16 gauge cold rolled steel with removable eorroM O' locked door • Dimensions—18 15/16"W x 27 3/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120°(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/-10°F(25°C+/-50C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 o Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) o Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) o Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignaLcom Plus 4—., 98830035-REV A PAGE 4 OF 4 08/12 (E) POTTER RA-6075 • The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F)109/6-93% @ 30°C(86°F)non-condensing . humidity Maximum Wire Length 6500 FT 0 Maximum Annunciators 31 Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters ®P Product includes 5 year warranty LIS'fE0 S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character, 16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. ' It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Install in accordance with compatible fire alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator �,1,� CA-6075 onnection a PLINK * a + A B Panel -� -}- -}- -{- Panel + onneWan Remote •UN -f• Annunciator -LIN ^^n0C1itln Remote Annunciator { m + m T < + a 1h + ,} Remote O Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870-Canada:888-882-1833-www.pottersignal.com PRINTED M USA MFG.#5406077-REV B-1 PAGE I OF 2 9/11 (E) POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) ww w Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW4 SW-5 Address SW-1 SW-2 SW-3 SW4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off I Off On PRINTED IN USA MFG.#5406077-REV B-I PAGE 2 OF 2 9/11 (E) POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features • 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel • Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, OPOTTER Gentex,Cooper-Wheelock and System Sensor. PSN-1000 Compatible with all Potter PFC-6000 series fire alarm control panels. fro S)Mt01 o Ramf,&, Power supply Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA UL 0 S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833-www.pottersignal.com PRINTED IN USA MFG.#8830032-REV B PAGE I OF 2 09/14 (E) POTTER PSN-1000(E) ® The Symbol of Protection POWER EXPANDER 18.91" n 17.60" TOP Uj 4.41" 3.75" DEPTH d � d d d N d "' i d fV ni d d 0 d LEFT SIDE RICI IT SIDE BOTTOM 0 Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA NEG.#8830032-REV B PAGE 2 OF 2 09/14 SYSTEM SENSOR' Photoelectric , Smoke Detectors System Sensor i3-series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- indicated maintenance and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Ustin s O / .•may M ® MEA MSFM C� �w LISTED p approved approved S911 d 11446 1272-1653:152 290-01-E 2093 3180932 i)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4W I-B)with thermal sensor rated at 135"F (57.2°Q.The detector shall include a mounting base for mounting to Th-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up;normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verlfy the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 VA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B dnd 4W-B:32°F to 1201F(0°C to 49°Q;2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box flinch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module FIT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM ®202rrge System Sensor. SENSOR 3825 Ohio Avenue•St.Charles,IL 60174 Roductspeproductinfor ectmchzogevnthoutnot-sio of this atn sheet. Phone:800-SENSOR2•Fax:630-377-6495 urentproduainrormatS-00-0including7-6/09.4 tverAono thisdaushee[ A05-0319-007•fi/09•p2169 P P OT T E R*I V, HM/• DCM-4 • The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 14 AWG 11 1•�°.°•' �r iwn/�rMNmm wap„ • Product includes a 5 year warranty NOTE: This addressable module does not support 2-wire smoke zs zi detectors. Stock Number: 1430822 c&us LISTED S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC 1000 Max Wiring Cpacitance of IDC IgF EOL Resistor 5.1K n Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L x 4.17" waterflow and valve tamper switches when they are located in the same (I06mm)W x 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. pp g Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.ponersignal.com 8830008-REV B • 7114 PAGE 1 OF 2 P P OT T E R*I V, HM/s ®C M-4 . The Symbol of Protection Dual Contact Module Setting the Address Each addressable module,smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box �o 0 � o o • 0 b ° ° O v O atti 0 0 Wiring Diagrams DCM4 With One ClassA Circuit NOl FROM FRCP OR C1 - PREVIOUS MODULE S+ ZI S- NO2 �- TO THE NEXT MODULE pppPp1p C2 0008 LED O Z2 SELECT STYLE D/ 000000<j NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM4 With TwoClassBCircuits NOI FROM FACP OR CI I END-OF-L PREVIOUS MODULE S+ Z INE RESISTOR 5.1 K OHM 1/2 W S- NO2 TO THE NEXT MODULE ""'no p C7 0000 LED O Z2 SELECT STYLE 0000 END-OF-LINE RESISTOR 5 IK OHM 1/2W Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignal.com =0 Owl-2006 DESIGNING,MANUFACTURING, i�.I 18 DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 E) POTTER PULL STATION SERIES DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS UL and cUL Listed,FM Approved,CSFM Listed,MEA Approved,ADA Compliant • Single or Dual Action PULL D LL OOWN Terminal connectors 1 ! 10 Amp Snap Action Switch Gold plated SPST contacts ro • Optional auxiliary contacts • Mounts on standard single gangbox • Surface backboxes available High-gloss red enamel finish • Glass breakrod Made in the U.S.A. Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-IT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-IT-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT-WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: I Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the normal position. For special application manual stations see bulletin#8910014. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-IT 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1T KL 1000451 SPST RMS-1T KO 1000450 SPST,key operated,no pull Weather Proof RMS-IT WP 1000401 Dual Action P32-IT-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 PULL STATION SERIES (E) POTTER DIE-CAST METAL • The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA [IRE :- ALARM Approved,ADA Compliant • Single or Dual Action PU L PULL GOWN Terminal connectors 10 Amp Snap Action Switch Gold plated SPST contacts • Optional auxiliary contacts • Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod o(�us, • Made in the U.S.A. Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a I0-amp snap action switch and stations shall be a P32-1T.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-IT LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT-WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"II x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the normal position. For special application manual stations see bulletin#8910014. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-IT 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-IT KL 1000451 SPST RMS-IT KO 1000450 SPST,key operated,no pull Weather Proof RMS-IT-WP 1000401 Dual Action P32-IT LP 1000476 SPST Weather Proof Dual Action RMS-IT WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097—REV L PAGE 1 OF 1 9/10 GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24 VDC The GHLF is a high quality,low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R I E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4"metal mounting plate which incorporates the popular Super-Slide®feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate®-Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C U� US C • Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSVUL 464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module • CSFM: Pending • Checkmate®-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBCAFCARC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: JV =� R=Red Faceplate MEMBER GHLFW 904-0530-002 24VDC W=White Faceplate ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max 24VDC Max 24VFWR Max 24VFWR Max Horn Mode Operating Operating Operating Operating ANSINL 464 ANSINL 464 Current Current Current Current Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) temporal 3 520 Hz 77.8 dBA 1 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA I_1emporaI4520Hz*1 81.5 dBA 1 83.4 dBA 75.9 mA 116.0 mA 1 108.1 mA 1 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32,to 120°F(0'to 49°C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unlitered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSI/UL average RMS method. ANSIML max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC NOTES: UL Listed THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal signal PULSING SIGNALING CIRCUITS Panel S+ S. S. H+ H- s+ s+ s H+ H• THE FOUR PULSE TEMPORAL PAI i ERN(TEMPORAL 4)CAN ONLY BE Supervised ti 0 0 ` 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE \ + •END OF SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. 01 GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-136-8381. 00 NOf 1r1pA Art CS o 0 o SCREW �%o 0 jN-' (optional)12 O RED WIRES O BLACKWII;t=S i o 9 0 o W N RMAL-L UD o Z � ° DECIBELJUMPER. 11ii o O FOR LOUD DECIBEL INSTALL JUMPER. SLIDE ONTO BRACKET Gentex Checkmate® Gentex Super•Siide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre-wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE:CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI LIL)for use with fire protective signaling systems(ANSI/UL 464)and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important materials GHLF-01 O GENTEX These materiels have been prepared by Gentex Corporation l Gentex')for informational atonal purposes only,are necessarily summary,and are not purported to some as legal advice and should not he used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-lo-dale,or in compliance with all relevant local,slate and federal laws,regulations and rules. The materials do not address all legal considerations as them is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195• 1.800.436.8391 •616.392.4219 Fax responsible for any action or failure io act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. • 1 (E) POTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input F voltage I Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x 0.5"(1.27 cm)deep • Jumper selectable temporal 3 or continuous tone • Horn frequency is 3100Hz 1 Terminal blocks(12 AWG to 18 AWG) Low current consumption r Variety of mounting options for new construction and retrofit applications r Synchronize using the AVSM Series control module MAP • ANSUUL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 32'to 120°F(0'to 49°C) 4890001 MHT 1224R R=Red facepaate 4890002 MHT-1224W W=Off-White faceplate 4890003 MHT-1224PR P=Plain 4890004 MHT-1224PW SIGNALING LISTED Product includes a S year warranty Description The MHT 1224 Series mini-hom is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT-1224 is ideal for applications where a dependable audible is ANSI/UL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm homs shall be Potter model MHT 1224.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems(ANSUUL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830065-REV A PAGE 1 OF 2 06/13 (E) POTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1224 MHT-1224 LISTED WIRING DIAGRAM FOR DUAL CLASS D CIRCUITS WITH A SINGLE AVS44 CONTROL MODULE CONTROL PANEL + — +11 - 0 • SYNCHRONIZATION FACV. MODULE ^ WT• M•w w tiUl'f It'PStO END OF LINE SIGNAL RESISTOR - C RCUIT ' EOLR \O RE RE WEDaF0 01 SIGNAL CIRCUITS WIA1N MHf-1)]d BLACK PIMA MACK OACRL Wiring Diagram EOIR Mini-Horn Wiring Use a screwdriver to break the jumper for a continuous tone. o o DO NOT BREAK 1 s JUMPER IF TEMPORAL 3 TONE IS NEEDED. 01) D tiJ Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT-1224 Current Ratings feet per ANSI/UL feet per ANSI/UL feet per ANSI/UL 464 Room dBA @ 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. Temporal 3 81 dBA 78 dBA 78-86 90 24 VDC UL Max 18 mA Continuous 86 dBA 83 dBA 78-86 90 12 VDC UL Max 13 mA NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 RMS current ratings are per ANSI/UL average RMS method.ANSIIUL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSI/UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FWR ratings,see installation manual. PRINTED IN USA MFG.#8830065-REV A PAGE 2 OF 2 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S O R I E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and p q G E outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan',-providing maximum visibility and reliability , • Unit Dimensions: 5.75"(14.61 cm) high x 4.75"(12.10 cm)wide x ps ; 4.18 (10.62 cm) deep � • 3/4"conduit knockouts ll' • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white GOE-R GOE-W GOELP OUTDOOR ENCLOSURE �. Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount c look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features } • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan"'-providing maximum visibility and reliability • Unit Dimensions: 5.75"(14.61 cm) high x 4.75"(12.10 cm)wide x 3.25" (8.255 ;may cm)deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white ., . GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage,the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications t� The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL 464 listed for use indoor and outdoor applications when used with the WSSPK Series speaker and speaker/strobe. Standard Features 1 ,o • ANSI/UL 464 listed • 1/2"conduit knockouts with metal washer reinforcement 1, • Wiremold knockouts for 500,700 Series and pendulum mount • Unit Dimensions: 6.20"(15.75 cm)square x 2.04" (5.18 cm)deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander'(GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57' (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT A AGENT BEZELS Applications 1 The Gentex ALERT and AGENT bezels are constructed of durable plastic and is fully compatible with the Commander2(GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • Easy to install • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander'(GC) Series strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.2" (15.75 cm) round x 1.67"(4.24 cm)deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice: 551-0031-02 G E N T E X These materials have been prepared by Gentex Corporation same For ice and shoal purposes only,are materials summary,and are no(purposed to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials CORPORATION are complete and accurate,up-to-date,or in compliance with all relevant local,slate and federal laws, regulations and rules.The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules to particular fact patterns.Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulalions or rules.Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice.Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion A E) POTTER 5-24 & HS-24 SELECTABLE CANDELA The Symbol of Protection STROBE &HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,&110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install signals „ — — Documented lower installation and operating costs s Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA r Switch for chime,whoop,mechanical and 24001-lz tone Tamperproof re-entrant style grill (I I Switch for continuous or temporal 3 tone(not available on whoop tone) I ! Surface mount with the AVBB(Surface Mount Back Box) l Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 320F to 120OF(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision.The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 240014z and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANS1/UL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005•TechSupport:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE I OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA ® The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION . 3 4 5 _® Mechanical Temporal 3 ON ON ON N® , Mechanical-Continuous OFF ON ON Cc w 2400Hz-Temporal 3 ON OFF ON 3¢ i 2400Hz-Continuous OFF OFF ON S Chime-Temporal 3 ON ON OFF `"® b H+ Chime-Continuous OFF ON OFF °'® �- Whoop ON OFF OFF ® r Whoop OFF OFF OFF NOTE: • Switch Positions I and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket Checkmate®Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without — terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector �i�j�J�jfN device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. Cd Break off pin and insert 1 into hole at the bottom of the selector to lock candela setting.Signal must be removed from bracket and pin pushed forward from backside out 'f of hole to change candela. L- To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectricSignal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA WG.#8830054-REV A PAGE 2 OF 4 06/13 1 i ES-24 P0TT� & H SELECTABLE CANDELA • The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSI/UL 1971) 10 ft.,perANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75,110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-Cust Service:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE &HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire ularul Control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal Panel Signal Signal S+ S+ 5• H+ H•?tENDOFLINE S.S+ S+ S- H+ H. S• S+ S- H+ H- Supervised 10 Supervised 0 0 0 a Signal Circuit Signal Circuit + \ + - IS END OF LINE �� ISTOR RESISTOR END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•wwwpottersigial.com PRINTED IN USA NEG.#8830054-REV A PAGE 4 OF 4 06/13 9 I 13 I 7 I 6 I 5 I q 1 3 1 2 I 1 AFAFW FIRE PROTECTION INC1730 Road DEVICE INSTALLATION REQUIREMENTSPARK 77 APARTMENTS VICINITY MAP Everetti6son WA 98204 425-290-9600 nx«w. DAVID MOW CDUNG Y01VTO) a' L 2tdE,0w0 0� Ka.TID i!1�£w♦KtMAT WIN 'Clot .t O rl11U I �• unonalw �.—r d wlwawxs �' BUILDING 8 r;w,nnEC BOT 12' 120904 ° D _ NFPA FIRE ALARM BBDBOB1713 IAfT nl:mrn rW11R ,� koy T� ffi r x r�xo'[ qe[I +r•u.. AIIPt:f Ibf'U Pa.S'll +'TE t {.r b n•a -'AP _�, O TS dk•„t RYQApI�)� co [4'wr M 4rr w-ur RNr hu.VAW r r r o��•�� W +8'°A% ARLINGTON WA �O crre � 1 FINISHED FLOGA ' •14'T3 CITY OP REOMOIID WVM MOW ..Or uaeur INSTALLATION NOTES .�1be11 Fire Alarm Symbol Legend 204TH STREET N E 1) Prior to calling for inspection,the installer shall provide s - documentation to the local AHJ stating that the system has been ENT] LOD REMOTE ANNUNCIATOR RA-9W5 POTTER w installed,tested,evaluated and confirmed to be in accordance with all '<? P' INTELLIGENT 10AMP REMOTEPOWER EXPANDER PSN-1000 POTTER 1 AREA OF WORK Wr y C governing codes and the approved plans.The Fire Alarm System � installer shall complete an NFPA72 Record of Completion(NFPA72 Ts] SPRINKLER TAMPER BY OTHERS BY OTHERS BUILDING 8 N Ci 10.18.2.1.1). The completed Record of Completion shall be provided to the AHJ inspector at the time of inspection(NFPA72 10.18.2.1.2.4). M DUAL INPUTCONTAC:MODULE Dcnla POTTER 1 BBOXA,Sandard baum.,a v > I o U# ❑F PULL STATION SINGLE ACTION P3+-1T POTTER I BBOX-2,Standard b-M—.e 4B'AFF [iJFU' 2) Instructions for the operating,testing and maintenance of the n G a J//�� Sgrci]p1¢ system,along with record drawings otherwise referred to as SMOKE PHOTO 2-WIRE 2W'-B SYS BE I BBOX S andard ba Ahdx,2 6L6a 2! t f'.W rc O ("as-built" and equipment specificationsshall be provided at an11.0Z.omZ, ) P LF pyp LED,LF,HORNISTROBE,MC.WH LLFHSW' WHEELDGK BBOX�Standard backbox.4 82'AFF I' $LI�i'�t r EV approved location(NFPA72 10.18.2.3). 'L`` " �� L'` E_ ®py'F STROBE EXCEDER24VM-C WALL WHITE STW WHEELOCK I BBOX2,Standard b—kh.x,2 07 AFF 3) All systems and devices shall be installed and tested per the � manufactures listing and the authority having jurisdiction(NFPA72 L�J°BD u: • r o u E m n HDRNISTROBE,EXCEDER 24V,Al-C WALL WHITE HSW WHEELDvK 4 BBOX-2,Slandndbackbax 2 82'AFF � 17'�` . l �_ REVISION RECORD r - �'O1""'IIn '� N DATE/DESCRIPTION 10.14.2.1).Label all device locations containing EOL resistors. - gulp m HORN LOW FREQUENCY,WH GHLFW CENTEX 16 0EQX4.SIMdWdb".W• 62 AFF y I 9 S �' _ a 4)FACP&all Remote Power Supplies REQUIRE a DEDICATED 120VAC 20amp circuit A notice placed in the FACP shall direct �H MINI HORN WH MHT-1224W POTTER E BSOX-2 S dadhxkbm,2 fit AFF 3 "0 '�—.2, �i.1--l—I personnel to the location of the electrical panel that is supplying I 1 DEDICATED power to the system(NFPA72,Section 10.5.5.1) The .s HORNrsrROBE 2 WIRE.M-c,RED,WALL Hs-2+wR PO TER 1 naoxa sundrd O.Oba.Z s'APF i r _ e a SHEET LIST DEDICATED circuit breaker that serves the fire alarm system shall be �] WATERFLOW SW_nCr; BYOTHERS BY OTHERS y ai 'G EF 1 I I FA 0.0 FA DETAILS Labeled and Secured against tampering with a RED breaker lockout ACP, ACPLOCATED In'BUILDING P3DB POTTER E a krBLDG>f Bt 1-J+--� (NFPA72,Section 10.5.5.2). ourcooR wsWEATHERPROOF ENCLOSURE GOELP POTTER 1 FA 1.0 FIRE ALARM _ ------------'�r� - j ) (1 � l,P .-� FA2.0RISER/CALCS 5)This property will have one FACP located in the Community IN G��� N B Building.Each residential building will have a Remote Power Supply CITY OF ARL111i Vf � s � fl r(j ^ ! � h l t B and a Remote Fire Alarm Annunciator connected to the main FACP in L/1 / +=: the Community Building.The FACP will monitor each buildings fire BUILDING DEPARTMENT i :BLDt�1^ I sprinkler system via SLC,the occupant notification devices in each /� ®� ®the building will only activated when a fire alarm device from that / ` -- T -' '✓ specific building(waterflow,smoke detector,pull-station) is activated. SYSTEM0 UTS DATE BY SITE / P HAS I N G P LAN SCALE:11 DATE: 11=1' 6) Wall mounted strobes shall be placed 80"minimum to 96" R uwrlr.w cmva PROJECTCT NAME maximum above floor level.(NFPA72 18.6.4.1&2).Wall mounted CO rra Und Anna uOdA strobes shall be sized in accordance with(NFPA72 Table 18.6.4.3.1(a). NGES AUTHORIZED eiling mounted strobes shall be placed and sized in accordance g NO CH with(NFPA72 Table 18.5.4.3.1(b). UNLESS APPROVED BY THE BUILDING INSPECTOR w 7) When MORE than two notification appliances are visible at the F Z Z Q same time whether they are in the same room or adjacent space d CIRCUIT LINE TYPE Circuit Legend � ; ZW within the field of view,the flash of those strobes shall be 8 �l�$g'� synchronized(NFPA72,Section 18.5.4.3.2(3)&(4). a/:€ Abbreviation Type Name I— Q z __ ` A i U #1614 FPLR 8LC-SICsNAL LINE CRKT Z = O laced between 42 and 48 inches above floor € g --- p d1' 6 d —{�' A N814 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT 8) Pull stations shall be a 0 level.Devices shall be red in color(ICC A117.1 309&NFPA 72 17.14.6 SBU S g4¢ d N B B #1814 FPLR Q J Z 9) Outdoor strobes required for approaching Emergency Vehicles to OFFICE COPY— A A SYSTEM INPUTS A B O D E F O N l a be located in the upper 25%of the building(at a serviceable height), 1 M.nrl r.%d:rm Deaf ♦ • • •• 1 � N Q and to be clearly visible from the emergency vehicle approach path. 1 smd..Dwlrron ♦ ♦ • •♦ d a ♦ • ♦♦♦♦ s Fire N Alarm Device Numbering Q 10)Fire Alarm circuits to be installed/secured/terminated in . dPdnw,ConlmlV.1'. ♦ • (SLC)ADORESSABLEDEVICES NOTIFICATION DEVICES f3L accordance with NEC,NFPA 72,IFC and Local AHJ requirements& a rbdaamnc Po..Fr.nwr ♦ ♦ s standards. . Fl.lVameYTUm Low O.d.ry ♦ • d Received cKtun CIRCUIT 7 op.CIIC°II •A DEVICEAOOREBt � pEVICEp 11)The means ofcommunication to the central stations for the fire ° Dio1e0F0uCANDELAp Na1no.Bon Appf.do.Orrdn 6lwn ♦ B SUC-WN SHEET DESCRIPTION alarm system is to be provided by a Potter UD-1000 DACT as per plan. to R.nbl.poxd,BuppYT war • t0 SEP ®6 2017 O 1System requires 2 x POTS telephone lines,1 of these lines is required A D C a H 1 SIGN-1W, � pp CD FIRE ALARM to be DEDICATED to the FACP.The FACP is located in building 17. OPERATIONAL MATRIX SMUKEUETECTOR SHOWN AS EXAMPLE DETAILS SHEET NUMBER FA 0.0 9 I 8 I 7 6 5 4 3 2 1 I 7, • � 1 � 1 1� l� � I.�It� 7• -� � ��y� _ 7tF�„a� � I A 9 8 7 ,• 6 5 4 3 2 ( 1 FIRE PROTECTION INC 1730 Gibson Road Everett,WA 96204 425-290-9800 DAVID tdOW I 120904, LEVEL III 17-1 �••.I UNITB-11 �L NFPA D UNITB-t0 r-----'� vuuxo;i;a UNIT B-9 I I UNIT B-12 �ytyy I Rt,Y L t' 't. - , TO PS I rl I, III J I I I nn I--- -- -.1�,•I JI f J 1 r l [")r I LITV OF REDMDND _ STAIRi V ORVI�MOW ENTRY �I i I ENTRf I siGSue •� uua... uuae� 1^+ ut6•B•f.l �: Jll-•r-----fit-A D. Wt_ .uam c 2syd H C O p OD>tlr� <pzGoa O omClrO 3RD FLOOR N Krw WK� OURyJR REVISION RECORD DATE/DESCRIPTION 1{161�TNNN(.YBUS)101NE FACP_ W{.11TEC IN BUIl0ING 17 16q fPLlt 810�-i — •ffQ�FIW-{��fT07ME PACP� r1&4 KYLRSO 2 -f6- ' I Atl a6 r _ SHEET LISTdvsaw -M r------- f- ,,.��^ti FA0.0 FA DETAILS ul•». r I_f I FA 1,0 FIRE ALARM j � � I q » UNIT B-7 FA 2.0 RISERICALCS B I UNIT B-2 UNIT B-3 I 1 L L scaF=� r UNITB-1 1 r- Type Type I -� 'U UNITB-6 UNIT BB TypeA I i „XD -_--- ---y - I UNIT BA A— Type ra, UNIT B-6 I.aTm owc - v Type 1 + r��rIR `II,-l -S� — ♦: -- t ---•F-s�w'L`a oA.rt.o.o r SGALE:118"=1� - --- DATE: 811117IA 4Fl � I - PROJECT NAMEI T" L_l�i JI I T I _I _T ----- I� .��. _ _ I -- W l �Yr _ ,I`c �—. -- ;i- _�! _ so {t� �. ._i 1_I I U 1 STAIR! I I 1 I STAIR/ w.•sa I. Z Z „ „ �'• jII`� III - ` _ r ENTRY L I u I ENTRY ( N Q t •—STAiRI — I I.� STAIR! DVS^ - I - — !L' __ "alm, W I -I ENTR\' 1 11 ENTRY f+1,09. ur _ - —�LI W I,� 'yl 1~I�7 5 - '• �tl� 1p, I I - c ■a 1 a• Z = Z I l I i t O �_ nl �- u I soroo• LR __-Z. --J L-t �°-----� �- s �. 1 d ~ ~ z sww t IeawN �, � I .�� MOM z Z J - A UP =>R- 1ST FLOOR N- N a N - 2ND FLOOR Q SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1.0 9 8 7 6 5 4 3 2 i I ,� I 9 8 I 7 - I 6 5 4 3 2 ' ,dFAPV FIRE PROTECTION INC. 1730 Gibson Road EVereff,WA 98204 425-290-960D DAVID MOW Battery Calculations for Panel:PS BUILDING 08 F,rl IL.p F1000.IMtELLRiEYIT 1006W R'OOIE YOYIER EIIYAFNfER Pars Na 0 t•I Descn tion -T-Slandb ITotal Standby! Alarm Total AlartR :.[i1.G L?� Pwd E,IoerpAnt 3-0 PSN-1000-M 1 10 AMP POWER EXPANDER-ME ___ 180000mA T5. A 215.000anAI 2150000m rlrvaNlsro! rpG215.0 ml 215.CHIMP 12090d L V L III Penphe�al Deve:es _ 1 SMOKE.PHOTO,2-INIRE ilnibahnl 00100mA aolo0mAl 65000mA1 650f10mI� P31.11 1 PULL STATION SINGLE ACT ION(INO-9, 00000mAi 0 01)(30mAl 00000 LLtMt1V LED LF,HORNIS tH HL.MG,WHINONicallon) _ 0u000mA UOUODTA 292000UmAi26280011- D -eTA - o7N01EEfO M"NVIYC.YAWL PIIi1C"t11e rf 0 00000n A JW00D wI Hs HORIS'STROBE FxCECER:W YO WMi.wMlE iNullcmn o00001n "9. _ 102 •40R 1 D o1i IaN+iowo+ErxYwNiNaEww - aaolti:l 9 et Y41n NFP,A -- IIA�f•-'-�:Itla NORIL Y.'N MMYtAeoMl-� �900001rM_-C _- T..tgOGM�l7i00001M RS-24WR HORNISTROBE 2 WIRE,M-C,RED,WALL Nab6cehpn! 0 0 IN 11¢IbOMrN OWBU.17f lml / 90103M raw VM x m SIW.YODDIrA� 0-00-OIN-yJl ATN TNIiINtiMy 7301 TowilknnA W06 yAD1E�7 Stendbybme:24 Hre 1 eM Alarm tme:5 Me, 0 467Ah C� Battery iequiremeM 22seAn � Conrperlsehm Factor;-Standby 12 NIIm/2 Reguiren+enl vnIn-pensa5m, CFtS �T4]3 Circuit Calculations Panel:PS Card:00 Circuil:SIG1 _ Circuit Calculations Panel:PS Card:00 Circuil:SIG2 Circuit Calculations Panel:PS Card:00 Circuit:SIG3 Cwa Name SIG+ ck q"" w enn-I11rr SW Glcvt Type Nohl11h1n Ternanel Volhage 204VDC Amperage 30000A CRA'tlpF NIM#dM Term§+al Vnh,g,204VDC Amperape 30000A Clrcw[Type Nethcahon Terminal Vakage:20 dV DC Amperage 30000A Cable 1614C TWISTED FPLR 416 Cable IEI4C TWISTED FPLR 016 Gable 1614CTWISTEDFPLR#16 Calculabons based on R.-,Total Length qTY ORREOMOND Calcdebans based on Rumm.g Tclal Length Celchdebpns based en Runrdng T-1 Length. _ CIAO6 AVIbN1t Nn AY,F:16?'F Mat ISY 167'F Maxi N:t9R .AOwRinOm.m _ 0a'I,+GtniA Aesrt,rro'I'VwAYrA tt7'F Ylat 1YMasy.cYAaT.a-v isx -- _ -"- �• -• ay(C0 .NO.vnr O App4me Dale Di¢ 'VORO _ Mgt G-BA41 L,a.cx;Part No Appliance Desc Currtnt _ trot! lt Da_nt_a Part No. _ AppO¢nee p!0*_ Ql><S�I Cur9Rt VOMay.¢Vog4ye - +Iv.1090NIV P81.•i0001� _ ..y _. 001 HSY/11«1/JIITROOC E+tCCOCRNV.M•C IAVALNM1E.2000 ! IN" LLFXSSW. V.IgNlY81Rl1BE W WIN INICD 4FA m ItOtF /0St71Vi tql S'1-V``STROBE EtlorOE :N¢t:C,WKI VMTE 15CD IQ 1F.000OAM'19 SIOTV. It0¢9SV _ __ flSl`71101S;91ROOE C7iE¢LR NV1lC.YVllll WMElOCO N 10." �11A00fY 10�20V 002 SPIN STROM LAtct C1l 2EVM-C-WALL WW1L ICU 2"•0 S7 /l 1 10'OIMVI �m S7W St"M EXCENR NY M•C WI¢L:ROIRE.IS=_ 19A i) _ 1Y0T!_ t0.t,4.1V1 ppp�dL�y� 003-S S7fiOBE E1tCEDER MVIWC WMl.1YW1E.1000 21'4 S7.NBY li .. 101916v1 001 S?M1511�OS�E#.EOER:WNL WIW.VNltE 1SC0 I ITC N. 10 Y�1 t0.151 09 211 SIRCBE.E%CFOkR 2AVM.C.WWl.wlat0.1000 W 07000o1 yt0a121V 101+ 004"FHjW LED-LF.110RwS7R004 A1C;wXy!twn .A 21C.0000 1f.37 ID0171VI OW ./IWWR0�.E%CEDER 74 "WALLLNe-IR»CD Tnp 19C, 10 161.39Y LV LEa li ttOR S1R0lE.1IL•w!4110CD 1 20700001M it7001V 10 f0^NJ L 00S lliXeY�i t4D,lF,�NC:iweiNOat MC,WN,IOCD 10'•0 »C Its f01485VI 00' µf1/YAV�LED.V ND'aYMRCISE MG WK flODp _ ►•0 10»)i _ _100f013N1, ILFN LOA Ir�XOR/:92R00E.lAC.MIN 110CD Y 2C.000OInA 10)09W 19.0L'2LY R--- --- _ --- '-" .- - - _ lV l�V.MORWb/RORE MC 11NE 1f000 it' »2.O7DtIN,10 to(M W m O OOQ.LLFRI LFA.V NORNIS7RO_ t__ _..__ 2�'0¢000O,N 19001 f0.0o5TV1 Ob0 MOLIr•Ilt>AtYTTROSE. %CEDER NV IYC VALL YA0IE S9CD W 4➢C i¢ l00107V1 ro- I.�.IOS20000rnA' - t.., G-0 1MI.0000eM W7 LVMIW IFDL V.IIOR/YliR00E MC Val 11006 0 s 4h F i#aaI G,vr4/0F011000ArA aot stw sneo¢e.E%cED1ie Nv"wc wxL vMelE./sw »'•o o)`v io i6i o,- ITo4 vOlASP.eeah1302TIi Tpta1 pop 0.790N NO-07251 (TAW pwp,ct)01H totA+ IATSYV s 7pY CMrW 12110FOOTA c��O� ,irilYplE-,.GYH11111N/+iW11ML9E p1►13fOy 5 0 o w r a of>w�0 Circuit Calculations Panel:PS Card:00 Circuit:SIG4 Circuit Calculations PanetPS Card:00 Circuit:51G5 aka GecuiName SIG4 CmunName SIG5 < Circuk Type Nodficallon Terminal Vollape 204V:DG Amperage 30000A Gvcu[Type Nolgipahon Terminal Vpkage 20,4VDC Amperage 30000A DY¢b.un Cable 16I40 TWISTED FPLR#16 Ceble:i6r4GTWRm-gTOWLeISTED FPLR n REVISION RECORD Calculabans besetl on Rumung Total Length CelcWabons posed pn Running Total Length C/kaY AmOMMrpwW'F 11)'F US.AOM alp 15% Dw*tW1!t M�IIA III-1McRp"i*yd�tbCO l- DATE fDE.�fC.t'tI1�lON Dev-�Part No _ApplwmMDesc O GL11111R 1�0a90,M0118wDrop Ds p'alt Dtte Dww" .wmni V61 VW PS/41 PFFM 700Y, _I__p!ti rot_ ~�m,JW XORN FREOOEM:.•;WH 44- 11010001M IONrI IO S02tVl �(C HIMLOWtR000EKYWli OF4 994000nA lYAWt_1. IOSDSWI lmm OOI IAIT•t ltI(I IiLNN.VfX S N.00riOSA 19 _ 110 Cdl HOMWINFREOOENCWWN IF-0YA ti00prr lvvwp! 000 000 11¢: IIOffAYBTRO![2WIFE WC,tffi01NAlL t10CD - -2C 110, t1F0.^PoY� 0,2151 Wn'17:,w►0N'IWIW wll T-0 7:000On 15?1Y 100177VI OOr- 014 110Rti LOWFRENwBw,:+-WH 11 o0s000WA,lua) 10 p11LrW HORN LOLvfR5Q1IE7+CYwlt xa o0soo--tY.901' o: SHEET LIST �diT. _ Np'Rfl1.bW rli[ou�Nt:v1- T MaD00rtM IY.S- 110Y WT121AR1 WM WRNS.WM nm Z).' +Y.btt w.N opcLa11.t3 w9XORyNn+ 5c 22000YFA I0 el tamrLawiReouE>NCYwH sa 9a�__ ro roxi9vl FAO.OFAOETAILS oC -- Haa:Lav FRE00En:v wX _ 5- 00rpaomlL•tan9N (M1m w:i4Zviw'w iN.NO+ W-0 2Z Iti11 to III FA 1.0 FIRE ALARM t CN N010100W Yaf s-0.Ili to iDSl MOISTY as uNLH e101oltowf lLOVE utl Vrlm 32- ;10A000peA to,lq;411 tM Mtl m �REC�"C�_. dlt lWfi^141V WI0 NORTt INN a6- 22.ama�w i�)0¢7v (o�a OMU MORNLOWFR¢ ANICIF wH 3VIC lw.r�diiuh +it ooiii4! FA 2.0 RISER/CALCS �OtO CHL HORN LOd FRaOUEKCt'YM S M401IO. ZnAn 01 NORN LOWFR¢00¢IpV,YM .Ir+O R. IY31}I p�OlO6V1 B O1Y ISNL6t IIDRIf IOW FRE00ENCV,LN1 1:-0 WA I1t00 p.1115Y1 Ott MIFF1 NYA It01W,Y111 i'A 22�"-" f027 10 p ptt OHt NORICIgV FR00•JE1VCt YIN ! wAOCPT1I SYNSYNII t0. DIC-07fp v Otl. OX... HORN LON FREOl,OA"'V Ya1 25" WtOWmA Il001N (O LIN, taW U71An1) .1111 AM OI N/r•I NO YN1 2 "J.DOC9MhA 1l36t7Y, temm 0M FFIcmtSbl+l Tw!VrA1g„i_t]vY 1 NK40I - - kerChrtwo•tiSO0W0^K (L1WVda0paaR00t%1 Tp1aI Ve`dO:CIM I.I1tJV. SCALE 1/8"=1' DATE: 811/17 PROJECT NAME Y V N W wZ � A W a /L/L/�yiyiyi (�17 T Z lF IVI Ivl Ivl L. V LF V FI ` + O & H A }g, R9 tim � J q L'! tJ'. � LC11 SXllie C4 W C ate, am a N Y € T PS elp BLDG OB ror. •.nx. nv - ,as ,,�1cc,aC SHEET DESCRIPTION L tF Lf WI FIRE ALARM RISER I CALCS FACP IN <F :" BUILDING T ;� SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 2 • �� � .: I I I I Permit#: 1631 Permit Date: 09/06/17 Permit Type: FIRE ALARM Project Nam e Park 77 Applicant Nam a Fire Protection, Inc. Applicant Address: 1730 Gibson Road Applicant, City, State, Zip: Everett,WA98204 Contact: David Mow Phone: 425-290-9600 Em al: david@fpiseattle.com Scope of Work: Mulit-Faro iy Valuation: 3500.00 Square Feet: 0 Num ber of Stories: 3 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 09/27/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wrier Nam e Caner Phone Zoning 00829100000103 2 0227 77thAvenue NE WDARLINGTON 910 Undeveloped INVESTMINT LLC (Vacant)Land Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# FIRE PROTECTION David Mow 4 25-290-9600 1 730 Gibson Rd CONSTRUCTION UBI 601 848 346 INC CONTRACTOR FIRE PROTECTION CONSTRUCTION Labor and INC David Mow 4 25-290-9600 1 730 Gibson Rd CONTRACTOR Industries FIREPI*021ML Inspections Date I nspection Type D escription S cheduled Date C om lieted Date I nspector S tatus 06/11/2018 FA00.FIRE ALARM 04/24/2018 B UILDING A pproved FINAL Plan Reviews Date Review Type D escription A ssigned To R eview Status 09/06/2017 FIRE ALARM B UILDING Fees Fee D escription N otes A m Omt Fire Alarm Plan Review Fee $88.90 Fire System Plan Review T able 4-1 $100.00 Processing/Technology $25.00 Total $213.90 Attached Letters Date Letter D escription 09/26/2017 Building Perm i Paym arts Date Paid By D escription P aym art Type A ccepted By A m Omt 09/26/2017 David Mow6 6585380 c c $213.90 O ttstanding Balance $0.00 Notes Date Note C reated By: 09/28/2017 Bldg.#8 Kristin Foster Uploaded Files Date File Nam e 09/27/2017 2656796-1631 Issued Perm t.pdf 09/06/2017 2583674-1631 Application.pdf 09/06/2017 2583444-1631 Specs and Plans.pdf