HomeMy WebLinkAbout7915 210TH PL NE_BLD1537_2026 RESIDENTIAL MECHANICAL
PERMIT APPLICATION
t�N Department of Community & Economic Development
City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND
OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION
AND INCLUDE ALL INFORMATION.
Project Address: 7915 210th PL NE Arlington WA
Project Description:Like in kind furnace replacement and AC addition
Owner: Ryan Pszonka
Address. 7915 210th PL NE City. Arlington State.WA Zip Code: 98223
Phone. 206-909-1735 Email:nordstromha@comcast.net
Applicant: Nordstrom Heating & Air Inc.
Address: 4717 87th Ave NE City. Marysville State.WA Zip Code: 98270
Phone. 425-335-4029 Email. nordstromha@comcast.net
CONTRACTOR INFORMATION
Contractor Name:Nordstrom Heating & Air
Address: 4717 87th AVe Ne City: Marysville State.WA Zip Code: 98270
License Number: nordsha884jw Expiration: 04-16-18
Phone: 425-335-4029 Email:Nordstrom ha@comcast.net
STAFF USE ONLY
Permit #: Accepted by: Date:
6/16LP Page 1 of 2
Y. RESIDENTIAL MECHANICAL
PERMIT APPLICATION
SING Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551
SELECT ALL PROPOSED APPLIANCES
Furnace (80+) Model #ADD2B060A9V3VA AFUE80
❑ Heat Pump Model # AFUE HSPE
AC Unit Model # 4A7A4024L1000b SEER 14
❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ
❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: [El
Pipe Material:
Pipe Size:
Distance from Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
F��
Applicant Signature: Date: 07/03/2017
Applicant Printed Name: Debbie Elgin
I hereby certify that the above information is correct and that the construction, installation for the above mentioned
property will be in accordance with the applicable laws of the City of Arlington and the State of Washington.
6/16LP Page 2 of 2
CITY OF ARLINGTON
238 N. OLYMPIC. :'1VE-ARI.INGTO , OVA. 98223
III IONE: (360)403=355 1
BUILDING PERMIT
Addrr=?915:IM Place NE Ptrmitz: IOW -
Puf"--10:twaaz;;_" ctl v aJuatkm:0.00
OWNER APPLICANT CONTRACTOR
,Nana:t'S70NKA RVAN M A AMIL Nium.`ecih%imm I leattng A.Air,Inc. IT-4M.. ,A AIR IVc
A\, mm 1314 POTI-ATC'H HFAC H Rn Mdru-aa:47I'87th Avc Nr. AW(Cs, 393ri SBth SImt N7r_
Cm,,Stuc lip:MARYSYII.I.F_WA 9717.71 City.Slab Zip:Arlirycttm.WA 911-1 i Or .`ta4:/VA4ARYS%7LLL WA 98270
rhum. Plwroe-<25-3354029 yhnna 47�-t.;- %):Q
MECM-0rICAL CONTRACTOR PLUMBING CONTRACTOR
Ngne:V.)RIISl ROM 1IL4,, lac&AIR N:: Nana.
Addw ;93U S&II 5tmd NE Addmw
i'ity.SmtC.Zip*MAKYSVILLE.WA 9927a Ca..5tatc,Zip:
Pbnne•42s-33.0r29 Phorw.
JOB DESCRIPTION
PERbIITT)'M Rcsidcntial Mcclwiical (.'kXX_YItAX: 2015
slilulFx ? cwa.TYPE
I)W ELM,40 UNITS. 1 CX c GRM'P:
SUILL)MA; cicc LOAD-
PERMIT APPROVAL
iAfiRttTOCLI PLYAlTTICITYAND%,revrf:I_AN'}WiLILAIINGCONSTRI:CTI)NANDINixN1Ki'fHFlA'4)RXAUTH0fUZ=D
i IT'RGfcY';NO I'FRS(nN WII L BE LNUILOYF7)IN V104-ATRON OF fHt'LAW W CUI)F(* THE uwrL OP w.-\smNc.ToN RFI.A rI\(r lY)
W'URKWN'SC(M)ENMATICNV INtiI,RAN('F:AN[)K(:W 1S.27.
7HfS AYHI j(:A nt)N 15 NOT A PERMIT L'N-M.SIGNrr)rIN'THE lit ill.lANts OFYI(IAL OR I IM ICR DCPUTV.AND ALA.FFF:ti AR L NA(L).
IT IS t INt.A1MFl 4-Tf)USF tllr;C :(_-VP)'A BUILDING OR STRI:(71 IRI:I I-11 A FINAL INSPE(.TK)N HAS BEEN%f kl)J-ANI)Al'PX(A',\L VR
A CERTU:GATE Of QCl t!P.1�1c'Y'HAti tiI:FP til2.\N7TtD. 1BC 11%IRCI 10.
\A I.VS T.Ar,N(yn('F::Sala c IxY rotating as cttrr¢ru:inn and in tic C itt o(Mo 6fon nt>ptst be mponod 0n)X%W stla tLx rcluru form
and l its'&.,i I' 1.
lIq
.SiFtAjrc flint r�al Gate 7-7 47 Rel=.CI By Dow
CONDITIONS
Approved as submitted.
�-IiLv YF3tMrr AI ITIIORt7",r)NI.V TIIr WnRK NOTrU r lLS?LXM.-1 L'OVMS WORK TO Rf:Tk-AVr rxN PRE V.S ri,yvkwLRrY CMLY. ANY
vONMLICTK).NON'i'iiL:?UI3UC:U(Ji1IAIN(C'IIRR` �I71 'AIiLS.I3RItiL�:\�`J hLSH(,rUL1J.L'1t.t1Ai11.I.RF(rJIRF:SlpgltAiE('fRMj$$IUI�.
PERMIT FEES
Dial Description Fee A(goutrat
7t'y2017 AC --lit $25.00
TI&2017 :urnace Ste 00
715,2017 Wchanical Fermi;Rase Foo S25 00
715.12017 Droeessing�7echnoiM Foe S25 00
Total Due: SI00.00
Tout Pavme-ae: S(i,)o
Ralaace Ivc: S106.00
CALL FOR INSPECTIONS
NA hen cA14H&_for au inwection please leave the Wln»tap kalnrmAtinn:
rerun(`umber,Type of Inspection bcsag/vQur,tcii.sa1I w briber Jw prefer couroin0 or ofterunoa
CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
% PHONE; (360)403-3551
BUILDING PERMIT
Address:7915 210th Place NE Permit#:1537
Parcel#:00805600002500 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:PSZONKA RYAN M&APRIL Name:Nordstrom Heating&Air,Inc. Name:NORDSTROM HEATING&AIR INC
Address: 1314 POTLATCH BEACH RD Address:4717 87th Ave NE Address:3930 88th Street NE
City,State Zip:MARYSVILLE,WA 98271 City,State Zip:Arlington,WA 98223 City,State Zip:MARYSVILLE,WA 98270
Phone: Phone:425-335-4029 Phone:425-3354029
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:NORDSTROM HEATING&AIR INC Name:
Address:3930 88th Street NE Address:
City,State,Zip:MARYSVILLE,WA 98270 City,State,Zip:
Phone:425-335-4029 Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: 2 CONST.TYPE:
DWELLING UNITS: 1 OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of it -oq st be ported on your sales tax return form
and coded City of Arlington#3101. r
Signature Print Name Date Released By Date
CONDITIONS
Approved as submitted.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
7/5/2017 A/C Unit $25.00
7/5/2017 Furnace $25.00
7/5/2017 Mechanical Permit Base Fee $25.00
7/5/2017 Processing/Technology Fee $25.00
Total Due: $100.00
Total Payment: $0.00
Balance Due: $100.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Community and Economic Development
Building Division
INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit
SITE holder or agent has posted this Inspection Record Card in a
conspicuous place on the premises.
OWNER: Y ? CONTRACTOR:
JOB ADDRESS: S 24OW 1Pj&k&tjL OWNER ADDRESS: Aj� I�TI'I E
USE of BUILDING: SFR PLAT NAME:
Description of Work: LOT#
PERMIT N0: S ,j S rinklered:
CONDITIONS: k, DATE ISSUED: ,S 2-VII TYPE GROUP
DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS
FOOTING
BUILDING FOUNDATION
INSPECTION LINE UNDERFLOOR
(360)403-3417 SHEARWALL
PLUMBING(groundwork)
GAS PIPING(groundwork)
ROUGH PLUMBING
ROUGH GAS PIPING
ROUGH HEATING&VENTILATION
FRAMING
INSULATION
WALLBOARD(SHEAR/RATING)
ROOF DRAINAGE
DEVELOPMENT STORM INFILTRATION
SERVICES GRADING
INSPECTION LINE CURB GUTTER&SIDEWALK
(360)403-3417 LANDSCAPE
DRIVEWAY
UTILITIES SIDE SEWER
INSPECTION LINE SEWER CLEANOUT/FINAL
(360)403-3508 WATER SERVICE INSPECTION
WATER SERVICE FINAL
CROSS CONNECTION FINAL
(360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection
Electrical must be signed off prior to final inspection
COMMENTS:
Community and Economic Development
,
Building Division
INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit
SITE holder or agent has posted this Inspection Record Card in a
conspicuous place on the premises.
OWNER: Pszonka CONTRACTOR: Nordstrom Heating and A/C
JOB ADDRESS:7915 210th Place NE OWNERADDRESS: 7915 210th Place NE
USE of BUILDING: SFR PLAT NAME:
Description of Work: Mechanical LOT#
PERMIT NO: 1537 Sprinklered:No
CONDITIONS: See Permit DATE ISSUED:7.6.2017 TYPE GROUP
DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS
FOOTING
BUILDING FOUNDATION
INSPECTION LINE UNDERFLOOR
(360)403-3417 SHEARWALL
PLUMBING (groundwork)
GAS PIPING(groundwork)
ROUGH PLUMBING
ROUGH GAS PIPING
ROUGH HEATING&VENTILATION
FRAMING
INSULATION
WALLBOARD(SHEAR/RATING)
ROOF DRAINAGE
DEVELOPMENT STORM INFILTRATION
SERVICES GRADING
INSPECTION LINE CURB GUTTER&SIDEWALK
(360)403-3417 LANDSCAPE
DRIVEWAY
UTILITIES SIDE SEWER
INSPECTION LINE SEWER CLEANOUT/FINAL
(360)403-3508 WATER SERVICE INSPECTION
WATER SERVICE FINAL
CROSS CONNECTION FINAL
(360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection
Electrical must be signed off prior to final inspection
COMMENTS:
Amw?,4wSAwdvd,
HEATING & AIR CONDITIONING
Submittal
Split System Cooling
4A7A40241-1000B
Illlil llllllllllll --- � [[[[
1111111111�111 � [[[[[[�[
� I 111lDllllll
I llllllllllllllll
III IIII [[[[[[[[l[[[[[
llllllllllllllll
IIIIII III [[[[[[[[[[[[[
IIII llllllllllllllll [
11111III [[[[[[[[[[I[
IIII llllllllllllllll [
Note: "Graphics in this document are for representation
only.Actual model may differ in appearance."
TAG:
t SAFETY WARNING
Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and
air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered
equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the
literature and on the tags,stickers,and labels that are attached to the equipment.
January 2017 4A7A4024L-SUB-1 C-E N �Ingersoll Rand
HEATING & AIR CONDITIONING
B
I�
ij
C �
SERVICE PANEL I
I
ELECTRICAL AND REFRIGERANT
COMPONENT CLEARANCES
PER PREVAILING CODES.
7
TOP DISCHARGE AREA SHOULD BE
UNRESTRICTED FOR AT LEAST 1524 (5 FEET)
ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF
RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT.
AND SHOULD BE AT LEAST 305 (12') FROM WALL AND
ALL SURROUNDING SHRUBBERY ON TWO SIDES.
OTHER TWO SIDES UNRESTRICTED.
ELECTRICAL SERVICE
PANEL
K
25 t l 1
A
22.2 (7/8) DIA, HOLE
LOW VOLTAGE
28.6 11-I181 DIA. N.O. WITH
22.2 17/8) DIA. HOLE IN CONTROL
BOX BOTTOM FOR ELECTRICAL
POWER SUPPLY]IG
ELECTRICAL ROUTING
N.O. FOR ALTERNATE
LIQUID LINE SERVICE VALVE.
E' I.D. FEMALE BRAZE
CONNECTION WITH 1/4' SAE GAS LINE I/4 TURN BALL SERVICE VALVE, 'D'
FLARE PRESSURE TAP FITTINGS. I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE
FLARE PRESSURE TAP FITTING.
Model Base A B C D E F G H J K
4A7A4024L 2 730 724 651 3/4 3/8 127 57 194 38 457
(28-3/4) (28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18)
SOUND POWER LEVEL
A-Weighted Sound Full Octave Sound Power[dB]
Model Power Level[dB(A)]
63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
4A7A4024L 71 74 71 65 68 67 63 56 50
Note: Rated in accordance with AHRI Standard 270-2008*For reference only
2 4A7A4024L-S U 8-1 C-E N
,�l�cP�'1cati1 �S�ida�-a!,
HEATING & AIR CONDITIONING
Product Specifications
OUTDOOR UNIT(d)(b) 4A7A4024L1000B W Certified in accordance with the Air-Source Unitary Air-conditioner
POWER CONNS.—V/PH/HZ(c) 208/230/1/60 Equipment certification program,which is based on AHRI standard
210/240.
MIN.BRCH.CIR.AMPACITY 14 (0) Rated in accordance with AHRI standard 270.
BR.CIR.PROT.RTG.—MAX.(AMPS) 20 Calculated in accordance with Natl.Elec.Codes.Use only HACR
circuit breakers or fuses.
COMPRESSOR CLIMATUFF(,�-SCROLL O) This value shown for compressor RLA on the unit nameplate and on
NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit
ampacity and max.fuse size.The value shown is the branch circuit
VOLTS/PH/HZ 208/230/1/60 selection current.
(0 No means no start components.Yes means quick start kit
R.L.AMPS(d)—L.R.AMPS 10.1—52 components.PTC means positive temperature coefficient starter.
FACTORY INSTALLED Optional kit shown.
M Standard Air—Dry Coil—Outdoor
START COMPONENTS(,'; NO W This value approximate.For more precise value see unit nameplate.
INSULATION/SOUND BLANKET NO (^) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid
COMPRESSOR HEAT NO 60 ft.For greater length consult refrigerant piping software Pub.No.
32-3312-0 ( denotes latest revision).
OUTDOOR FAN PROPELLER
DIA.(IN.)—NO.USED 18.2—1
TYPE DRIVE—NO.SPEEDS DIRECT—1
CFM C 0.0IN.W.G.M 2450
NO.MOTORS—HP 1-1/8
MOTOR SPEED R.P.M. 1075
VOLTS/PH/HZ 200/230/1/60
F.L.AMPS 0.90
OUTDOOR COIL—TYPE SPINE FIN"'
ROWS—F.P.I. 1-24
FACE AREA(SQ.FT.) 13.75
TUBE SIZE(IN.) 3/8
REFRIGERANT
LBS.—R-410A(O.D.UNIT)M 4 LBS.,11 OZ
FACTORY SUPPLIED YES
LINE SIZE—IN.O.D.GAS(h) 3/4
LINE SIZE—IN.O.D.LIQ. 3/8
CHARGING SPECIFICATIONS
SUBCOOLING 10OF
DIMENSIONS H X W X D
CRATED(IN.) 30.1 x 26.7 x 30
WEIGHT
SHIPPING(LBS.) 153
NET(LBS.) 133
4A7A4024L-SUB-1 C-EN 3
TDD213060MV SUB-1 B
TAG:
Downflow/Horizontal
TDD2B060A9V3VA Gas Furnace - Variable
ADD2B060A9V3VA Speed - 2 Stage Heat
5/8"
17-1/2" 28"
16-1/4" 24-1/2"
19-5/8"
5/8" SIDE PANEL
1/2" CUTOUT FOR
5" 0 SIDE PANEL CUTOUT HORIZONTAL
FOR HORIZONTAL VENTING ' VENTING
THROUGH THE CABINET 9-5/8" THROUGH
7/8" DIA. HOLES D 4 1/8 �' ` THE CABINET
ELECTRICAL 3-1/2 5"
CONNECTION
� 3-3/8 I 40"
7/8" HOLE
WITH PLUG
FLUE
3/4" 2-1/8" OPENING
N.
31
� -4 .�
� �, 2-1/8"
0 29 1/2 1-5/8" HOLE
0 WITH PLUG
3/4"
DIA. GAS
D D D 20-1/4" CONNECTION
(ALTERNATE)
' D D 1-5/8" HOLE
12 3/8
3/4 / ` " 3-15/16' D D WITH PLUG
/ � D D 10"
D�
19"
7-3/8"
8-1/44
5-5/16"
1-5/8" HOLE WITH PLUG
3-3/4"
1-5/8" DIA. HOLE WITH PLUG
GAS CONNECTION (ALT)
1-5/8" HOLE WITH PLUG
0 2015 Ingersoll Rand
*DD2BO6OA9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SETTING S4-3 S4-4 0.1 0.3 0.5 0.7 0.9
CFM 547 593 571 567 544
LOW ON ON TEMP RISE 53 49 51 51 53
WATTS 48 80 107 143 170
HEATING CFM 658 664 658 658 652
1ST MEDIUM - ON OFF TEMP.RISE 44 44 44 44 44
STAGE WATTS 65 92 122 155 197
CFM 735 761 761 764 762
HIGH OFF OFF TEMP.RISE 39 38 38 38 38
WATTS 75 120 155 190 230
CFM 743 777 775 783 772
LOW ON ON TEMP.RISE 60 57 57 57 58
WATTS 75 120 155 195 230
HEATING CFM 874 887 881 894 894
2ND MEDIUM - ON OFF TEMP.RISE 51 50 50 50 50
STAGE WATTS 105 150 185 230 270
CFM 996 1013 1041 1058 1069
HIGH OFF OFF TEMP.RISE 45 44 43 42 42
WATTS 143 192 250 307 337
*DD2BO6OA9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
UNIT SIZE SETTING
(TONS) S3-1 S3-2 S3-3 S3-4 0.1 0.3 0.5 0.7 0.9
LOW ON ON OFF ON CFM 533 563 546 534 515
(350 CFM/TON) WATTS 45 75 100 130 160
15 NORMAL ON ON OFF OFF CFM 609 627 624 606 607
(400 CFM/TON) WATTS 55 90 115 150 180
HIGH OFF CFM 664 683 690 687 680
(450 CFM/TON) ON ON ON WATTS 65 95 135 165 200
LOW OFF ON OFF ON CFM 693 714 708 706 712
(350 CFM/TON) WATTS 65 105 135 170 210
2.0 NORMAL OFF ON OFF OFF CFM 780 821 813 810 816
(400 CFM/TON) WATTS 85 130 165 205 245
HIGH OFF ON ON OFF CFM 886 896 901 925 930
(450 CFM/TON) WATTS 110 150 200 250 285
LOW CFM 865 882 869 884 885
(350 CFM/TON) ON OFF OFF ON WATTS 105 145 185 275 265
2.5 NORMAL ON OFF OFF OFF CFM 977 983 1014 1035 1019
(400 CFM/TON) WATTS 135 180 235 290 330
HIGH CFM 1097 1125 1155 1169 1169
(450 CFM/TON) ON OFF ON OFF WATTS 170 235 305 350 405
LOW OFF OFF OFF ON CFM 1006 1034 1056 1072 1067
(350 CFM/TON) WATTS 145 200 255 315 352
3.0" NORMAL** OFF OFF OFF OFF CFM 1169 1202 1226 1221 1217
(400 CFM/TON) WATTS 215 265 355 390 440
HIGH OFF TOFF ON OFF CFM 1313 1339 1360P369711357
(450 CFM/TON) WATTS 290 370 425525
NOTES:
1. 'FIRST LETTER MAY BE"A"OR"T"
2. `*FACTORY SETTING.
3. CONTINUOUS FAN SETTING:HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE.
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT&HUMID CLIMATE SETTING:
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
INDOOR BLOWER TIMING COOLING OFF - DELAY OPTIONS
Heating: The ECM Fan Control controls the variable speed
indoor blower. The blower"on"time is fixed at 45 seconds after SWITCH SETTINGS SELECTION NOMINAL-
ignition. The FAN-OFF period is field selectable by dip switches AIRFLOW
#2 and #3 on the Integrated Furnace Control at 60, 100, 140,
or 180 seconds. The factory setting is 100 seconds, (See unit 5-OFF 6-OFF NONE SAME
wiring diagram).
5-ON 6-OFF 1.5 MINUTES 100%'
Cooling:The fan delay-off period is set by dip switches on the
ECM Fan Control board connected to the Integrated Furnace 5-OFF 6-ON 3 MINUTES 50%
Control. The options for cooling delay off is field selectable by
dip switches #5 and #6. However, dip switch #1 on the Inte- 5-ON___r 6-ON 50- 1000,16
grated Furnace Control must be set to"ON"for cooling mode to
function properly. `-This setting is equivalent to BAY24XO45 relay benefit
The following table and graph explain the delay-off settings:
"" -This selection provides ENHANCED MODE,which is
- This selection provides a ramping up and ramping down a ramping up and ramping down of the blower speed to pro-
of the blower speed to provide improved comfort,quietness,and vide improved comfort, quietness, and potential energy sav-
potential energy savings. The graph below shows the ramping ings.See Wiring Diagram notes on the unit or in the Service
process. Facts for complete wiring setup for ENHANCED MODE.
The graph which follows, shows the ramping process.
10006 if necessary
80°6
Dehumidify
50% 50%
Fast Coil Cooling Efficiency
OFF OFF
1 l 7.5 i 3
minute minutes minutes
General Data
TYPE Downflow/Horizontal VENT COLLAR—Size(in.) 4 Round
RATINGS 2 HEAT EXCHANGER
1st Stage Input BTUH 39,000 Type-Fired Alum.Steel
1st Stage Capacity BTUH(ICS) 3 31,200 -Unfired
2nd Stage Input BTUH 60,000 Gauge(Fired) 20
2nd Stage Capacity BTUH(ICS) 3 48,000 ORIFICES—Main
Temp.rise(Min.-Max.)'F. 35-65 Nat.Gas.Qty.—Drill Size 3—45
BLOWER DRIVE DIRECT L.P.Gas Qty.—Drill Size 3—56
Diameter-Width(in.) 10 x 7 GAS VALVE Redundant-Two Stage
No.Used 1 PILOT SAFETY DEVICE
Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition
CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot
Motor HP 1/2 Number 3
R.PM. VARIABLE POWER CONN.—V/Ph/Hz 115/1/60
Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 10.5
FLA 7.7 Max.Overcurrent Protection(amps) 15
COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 1/2
Drive-No.Speeds Direct-2 DIMENSIONS H x W x D
Motor HP PSC[Shaded Pole]-RPM 1/100/[1/1451-2543/1727 Crated(In.) 41-3/4 x 19-1/2 x 30-1/2
Volts/Ph/Hz 115/1/60 Uncrated(in.) 40 x 17-1/2 x 28-1/2
FLA PSC[Shaded pole] 0.70/0.40/f0.23/0.201 WEIGHT
FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 140/129
Type Recommended High Velocity
Hi Vel.(No.-Size-Thk.)Shipped 2-14 x 20- 1 in.
Central Furnace heating designs are certified by the American Gas Association Inc.Laboratories.
Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level.
Based on U.S.Government Standard Tests.
The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes.
Customer Name
Comfort Advisor
A1G F���E
L
CITY OF ARLINGTON
23& N. 0 L YMPICA V E- A R1.INGTON, WA, 99.2.2 3
I'll]ONE.- (3560) 44)3-3551
BUILDING PERAUT
1.tWrrim 1 35 2LM FUtem NE Permit 9: I.U'y
pal.Lx%,0 VajunLxyn:f;W
0'%WER APPLICAN4T CONTRACTOR
'arw:r"W.N11KA R�'AVW k ARIKJI Namu.`NuL-rarr,i katinq A Air,snc 'olykk %()Ktr I,Rom E & ki k r,,t,
%,;drc-N: 1.114 F9:;f'.,%TCH K l..,v,m F I Addrusy:-F I". a74h Avc NI-. A'Mrizi." 3940"1' 51;%%7 Nr
Cm,swc 7 1:VAR%-'CVl I I )A A!13717[
Gily.Swic Zip:Arlir.Loin.W.1%IWI� (';,r,,ti70i P MAAys%j-77-r--K.'%01tu
K-Pmc-425-335-102Y Fhnm,,4--
-%EECRAINICAL CONTRACTOR PLUMBING CONTRACTOR
Nknic Nurrx.
A&WN5 NI- AddicLW
I-in 'Sryac.i ip MARYS"VII.L E.'i;,.A 9927,'! Zrv:
fllwfu,
EN7; k.
FXF1
JOB DESCRIPTION
?CRI,VT TN M Rcsidcrifial Mechanical C.L%Lij y 1 2015
2 TYrIf
(XV G R(Yjrl:
kx- c LOAD:
PERMIT APPROVAL
1 A7;4f:R f
'j C R1i'IJJ UNGMY WIT I C1 I YAN 1.1 NIATI: AM)IN iXJV,.4 T HF.AA)R)k 4,1 'niii .1Z
p"S,()N 4' II I BE EMMLOM)IN V104I.AT30N C:07 rHF I..06W)K OF WASI IM--To %:W.E-J A;I Vj- [-(-.j
COMPTN&-)I'l(A I KS 1. K'(.'kz. 1)R(, I N,27
i4 A -kN
HP, VK ir:iq 11()N IS NLel,.A["iv
W7 L.N, 71j,SIG T.D WT.14F.11H 01111 M i 4)F :)It 1135,1 MR T>7?1-70VAND-,V-L F-F F-1 A X L 11A,11
'T P,%,k Ni. 11.)U F UK-1F7f Bk-41.WN6 OR STRUVI '�W- A FINAJ,INVECTnUNIL-�S 1377,NV,10F. -�, gad
A I,"-PUL . '.m.,TE OF Cy.C'UP,%'%WYHA% 91--KK 4 rK-V-41-1111. 15CE 19ARC I I re.
WS UX%011CF;54i1s Lax mining to cnawwrinn and c4)ns!rthjlx srint calls in dkr Ciq ofArjItaxl6n mrst he etporied rn%,V Ak,%A-.% -jurff *uvm
CONDITIONS
Appr-ty-ved as submitted.
0V YTIT," xRW'WCTTU .1ilLS 11R7VA fL
N-S ljkL`C T Ftlul-JU M.MAIN IVI IRHS SMFWAI K.5,Dr(JVCWA)`&?-VLVQ1JLUt.LTL i 1,h 11 1. ,TAFA7C,
PERMIT FEES
ails cescapfian Fee Aftwount
A(C LMit S2500
7'52v'17 Furnace S2.-c:0
7..15=7 Mesthank-al Permt Rase F-98 $2500
Fee $25 W
TOW Due: SAO."
TOW psymeaff!
50-30
Ralsoct Due: $106.04
GALL FOR INSPECTIONS
RVILVENG 0"s 403-34[Ir
'A hen c-AlUlle ror no ionsm6on pleme leave the FWjlwjmZ inflirni-I root.
Pffunk Nwnber.Type of Inspection bring tvqjjr.%rrd,natt 1-1stAier 71w prvftr rnotru ing or afternoon
10 CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:7915 210th Place NE Permit#:1537
Parcel#:00805600002500 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:PSZONKA RYAN M&APRIL Name:Nordstrom Heating&Air,Inc. Name:NORDSTROM HEATING&AIR INC
Address: 1314 POTLATCH BEACH RD Address:4717 87th Ave NE Address:3930 88th Street NE
City,State Zip:MARYSVILLE,WA 98271 City,State Zip:Arlington,WA 98223 City,State Zip:MARYSVILLE,WA 98270
Phone: Phone:425-335-4029 Phone:425-335-4029
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:NORDSTROM HEATING&AIR INC Name:
Address:3930 88th Street NE Address:
City,State,Zip:MARYSVILLE,WA 98270 City,State,Zip:
Phone:425-335-4029 Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: 2 CONST.TYPE:
DWELLING UNITS: 1 OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC1I0.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City p i o st be rted on your sales tax return form
and coded City of Arlington#3101. 1
Signature Print Name Date Released By Date
CONDITIONS
Approved as submitted.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
7/5/2017 A/C Unit $25.00
7/5/2017 Furnace $25.00
7/5/2017 Mechanical Permit Base Fee $25.00
7/5/2017 Processing/Technology Fee $25.00
Total Due: $100.00
Total Payment: $0.00
Balance Due: $100.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
RESIDENTIAL MECHANICAL
f�lJN(+1D
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND
OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION
AND INCLUDE ALL INFORMATION.
Project Address:7915210th PL NE Arlington WA
Project Description:Like in kind furnace replacement and AC addition
Owner: Ryan Pszonka
Address: 7915 210th PL NE City:Arlington State'.WA Zip Code: 98223
Phone: 206-909-1735 Email:nordstromha@comcast.net
Applicant: Nordstrom Heating & Air Inc.
Address:4717 87th Ave NE City: Marysville State WA Zip Code: 98270
Phone: 425-335-4029 Email: nordstromha@comcast.net
CONTRACTOR INFORMATION
Contractor Name•Nordstrom Heating & Air
Address:4717 87th AVe Ne City: Marysville State WA Zip Code: 98270
License Number:nordsha884jw Expiration: 04-16-18
Phone:425-335-4029 Email:Nordstromha@comcast.net
STAFF USE ON Received
Permit#: Accepted by: Date: JUL 0 3 2017
6/16LP Page 1 of 2
IN
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
lrN
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551
SELECT ALL PROPOSED APPLIANCES
Furnace (80+) Model#ADD2B060A9V3VA AFUE80
❑ Heat Pump Model#. AFUE HSPE
AC Unit Model # 4A7A4024L1000b SEER 14
l� Freestanding Stove Fire Place Insert It Outdoor BBQ
❑ Gas Piping Solid-Fuel Appliance Other
Gas Piping Information
Not Applicable:
Pipe Material:
Pipe Size:
Distance from Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
�e�Gte�C9r:�r 07/03/2017
Applicant Signature: Date:
Applicant Printed Name: Debbie Elgin
I hereby certify that the above information is correct and that the construction, installation for the above mentioned
property will be in accordance with the applicable laws of the City of Arlington and the State of Washington.
6/16LP Page 2 of 2
4*W?AWS7�dard,
HEATING & AIR CONDITIONING
Submittal
Split System Cooling
4AM40241-100013
IIIIIIIIIIIIIIII �[[[�[
I I 111111111111C; ,�f,
Ilf flllllf�l II 11 [[I[[[�[
��II llllllllll
IIIIIIIIII II 1111111 � Il[[I[[[[I[[[[
illll ll1111111
IIIIIII�II 111 [DII[I[II[[[[
Ilil lllllllllhll
Illllllllll
J111111 111111111 [
IIIIIIIII I[[[II[II[[Q
III ]ll1111111111111
1_
Note:"Graphics in this document are for representation
only.Actual model may differ in appearance."
TAG:
i SAFETY WARNING
Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and
air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered
equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the
literature and on the tags,stickers,and labels that are attached to the equipment.
January 2017 4A7A4024L-SU13-1 C-EN 4#)Ingerso►lRand
�C� 153r1
4ti we ao SS wdmd.
HEATING & AIR CONDITIONING
B
� I
SERVICE PANEL
ELECTRICAL AND REFRIGERANT
COMPONENT CLEARANCES
PER PREVAILING CODES.
i
TOP DISCHARGE AREA SHOULD HE
UNRESTRICTED FOR AT LEAST 1524 (5 FEET)
ABOVE UNIT ONIT RH m D RF PI AFFD SO ROOF
RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT,
AND SHOULD BE AT LEAST 305 (I2"1 FROM WALL AND
ALL SURROUNDING SHRUBBERY ON TWO SIDES.
OTHER TWO SIDES UNRESTRICTED,
ELECTRICAL SERVICE
PANFI
K
zs (u
A
22.2 (II BL DIA.LT HOLEAGC LOW VO
28.6 (I-II8) DIA, N,O. RITN -�
22.2 (7I8) DIA. HOLE IN CONTROL
BOX BOTTOM FOR ELECTRICAL
POWER SUPPLY H
P
J .0. FOR ALTERNATE
0 ELCCTRICAL ROUTING
L I011ID LIRE SERVICE VALVE.
'E' I.D. FEMALE BRAZE
CONNECTIONGAS LINE 114 TURN BALL SERVICE VALVE, 'D'
WIT11 IN' SAE
FLARE PRESSURE TAP fITiINGS. I.D. FEMALE BRAZED CONNECTION WITH I14' SAE
FLARE PRESSURE TAP FITTING,
Model Base A B C D E F G H ] K
4A7A4024L 2 730 724 651 3/4 3/8 127 57 194 38 457
(28-3/4) (28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18)
SOUND POWER LEVEL
Model A-Weighted Sound Full Octave Sound Power[dB]
Power Level[dB(A)1 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
4A7A4024L 71 74 71 65 68 67 63 56 50
Note:Rated in accordance with AHRI Standard 270-2008*For reference only
2 4A7A4024L-S1JB-1 C-EN
' r
Akoffew S?iwdc�.
HEATING & AIR CONDITIONING
Product Specifications
OUTDOOR UNIT(.)(b) 4A7A4024L1000B 0) Certified in accordance with the Air-Source Unitary Air-conditioner
POWER CONNS.—V/PH/HZ C0 208/230/1/60 Equipment certification program,which is based on AHRI standard
210/240.
MIN.BRCH.CIR.AMPACITY 14 (b) Rated in accordance with AHRI standard 270.
BR.CIR.PROT.RTG.—MAX.(AMPS) 20 (c) Calculated in accordance with Natl.Elec.Codes.Use only HACR
circuit breakers or fuses.
COMPRESSOR CLIMATUFFS-SCROLL (a) This value shown for compressor RLA on the unit nameplate and on
NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit
ampacity and max.fuse size.The value shown is the branch circuit
VOLTS/PH/HZ 208/230/1/60 selection current.
R.L.AMPS(d)—L.R.AMPS 10.1—52 N) No means no start components.Yes means quick start kit
components.PTC means positive temperature coefficient starter.
FACTORY INSTALLED Optional kit shown.
START COMPONENTS(e> NO M Standard Air—DryCoil—Outdoor
(9) This value approximate.For more precise value see unit nameplate.
INSULATION/SOUND BLANKET NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid
COMPRESSOR HEAT NO 60 ft.Forgreater length consult refrigerant piping software Pub.No.
32-3312-0*(*denotes latest revision),
OUTDOOR FAN PROPELLER
DIA.(IN.)—NO.USED 18.2—1
'TYPE DRIVE—NO.SPEEDS DIRECT-1
CFM @ 0.0IN.W.G.(0 2450
NO.MOTORS—HP 1-1/8
MOTOR SPEED R.P.M. 1075
VOLTS/PH/H Z 200/230/1/60
F.L.AMPS 0.90
OUTDOOR COIL—TYPE SPINE FINTM
ROWS—F.P.I. 1-24
FACE AREA(SQ.FT.) 13.75
TUBE SIZE(IN.) 3/8
REFRIGERANT
LBS.—R-410A(O.D.UNIT)(9) 4 LBS.,it OZ
FACTORY SUPPLIED YES
LINE SIZE—IN.O.D.GAS(h) 3/4
LINE SIZE—IN.O.D.LIQ. 3/8
CHARGING SPECIFICATIONS
SUBCOOLING 10°F
DIMENSIONS H X W X D
CRATED(IN.) 30.1 x 26.7 x 30
WEIGHT
SHIPPING(LBS.) 153
NET(LBS.) 133
4A7A4024L-SUB-1 C-EN 3
TDD213060MV SUB-1 B
TAG:
Downf low/Horizontal
TDD26060A9V3VA Gas Furnace - Variable
ADD2B060A9V3VA Speed - 2 Stage Heat
5/8'
17-1/2"/ 28"\i6-1/4" 24-1/2"
i
5/8` SIDE PANEL
1/21 CUTOUT FOR
5"0 SIDE PANEL CUTOUT i HORIZONTAL
FOR-HORIZONTAL VENTING ' VENTING—
THROUGH THE CABINET 9-5/8" THROUGH
7/8" DIA.HOLES 4-1/8 �'` ` THE CABINET
ELECTRICAL 3-1/2 5^ 1 1
CONNECTION 1
% 3-3/8 1 1 40"
1 7/8" HOLE
WITH PLUG
FLUE
3/4 y OPENING
2-1/8^ t
� 31
��- 4
� `1 2-1l8"
18" \ '0-a
i
go 29 1 2" 1-5/8"HOLE
WITH-PLUG
1-1/2" DIA. GAS
20-1/4" CONNECTION
0 Q (ALTERNATE)
1-5/8" HOLE
3/4" • . 12-3/8" 3-15/16' WITH PLUG
10.
19" 7-3/8
5-5/16"
1/2"
1-5/8"HOLE WITH PLUG
3-3/4"
1-5/8" DIA. HOLE WITH PLUG
M, GAS CONNECTION (ALT)
1-5/8"HOLE WITH PLUG
0 2015 Ingersoll Rand
*DD28060A9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SETTING S4-3 S4-4 0.1 0.3 0.5 0.7 0.9
CFM 547 593 571 567 544
LOW ON ON TEMP RISE 53 49 51 51 53
WATTS 48 80 107 143 170
HEATING CFM 658 664 658 658 652
1ST MEDIUM** ON OFF TEMP.RISE 44 44 44 44 44
STAGE WATTS 65 92 122 155 197
CFM 735 761 761 764 762
HIGH OFF OFF TEMP.RISE 39 38 38 38 38
WATTS 75 120 155 190 230
CFM 743 777 775 783 772
LOW ON ON TEMP.RISE 60 57 57 57 58
WATTS 75 120 155 195 230
HEATING CFM 874 887 881 894 894
2ND MEDIUM** ON OFF TEMP.RISE 51 50 50 50 50
STAGE WATTS 105 150 185 230 270
CFM 996 1013 1041 1058 1069
HIGH OFF OFF TEMP.RISE 45 44 43 42 42
WATTS 143 192 250 307 337
*DD2B060A9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
UNIT SIZE SETTING
(TONS) S3-1 S3-2 S3-3 S3-4 0.1 03 0.5 0.7 0.9
LOW ON ON OFF ON CFM 533 563 546 534 515
(350 CFM/TON) WATTS 45 75 100 130 160
15 NORMAL ON ON OFF OFF CFM 609 627 624 606 607
(400 CFM/TON) WATTS 55 90 115 150 180
HIGH OFF CFM 664 683 690 687 680
(450 CFM/TON) ON ON ON WATTS 65 95 135 165 200
LOW CFM 693 714 708 706 712
(350 CFM/TON) OFF ON OFF ON WATTS 65 105 135 170 210
2.0 NORMAL OFF ON OFF OFF CFM 780 821 813 810 816
(400 CFM/TON) WATTS 85 130 165 205 245
HIGH CFM 886 896 901 925 930
(450 CFM/TON) OFF ON ON OFF WATTS 110 150 200 250 285
LOW CFM 865 882 869 884 885
(350 CFM/TON) ON OFF OFF ON WATTS 105 145 185 275 265
2.5 NORMAL ON OFF OFF OFF CFM 977 983 1014 1035 1019
(400 CFM/TON) WATTS 135 180 235 290 330
HIGH ON OFF ON OFF CFM 1097 1125 1155 1169 1169
(450 CFM/TON) WATTS 170 235 305 350 405
LOW OFF OFF OFF ON CFM 1006 1034 1056 1072 1067
(350 CFM/TON) WATTS 145 200 255 315 352
3.0** NORMAL** OFF OFF OFF OFF CFM 1169 1202 1226 1221 1217
(400 CFM/TON) WATTS 215 265 355 390 440
HIGH OFF OFF ON OFF CFM 1313 1339 1360 1369 1357
(450 CFM/TON) WATTS 290 370 425 500 525
NOTES:
1. *FIRST LETTER MAY BE"A"OR"T"
i 2. **FACTORY SETTING.
3. CONTINUOUS FAN SETTING:HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE.
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT&HUMID CLIMATE SETTING:
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
INDOOR BLOWER TIMING COOLING OFF-DELAY OPTIONS
Pleating: The ECM Fan Control controls the variable speed
indoor blower. The blower"on"time is fined at 45 seconds after SWITCH SETTINGS SELECTION NOMINAL-
ignition. The FAN-OFF period is field selectable by dip switches AIRFLOW
#2 and#3 on the Integrated Furnace Control at 60, 100, 140,
or 180 seconds. The factory setting is 100 seconds, (See unit 5-OFF 6-OFF NONE SAME
wiring diagram):
5-ON 6-OFF 1.5 MINUTES 100%*
Coaling:The fan delay-off period is set by dip switches on the
ECM Fan Control board connected to the Integrated Furnace 5-OFF 6-ON 3 MINUTES 50%
Control. The options for cooling delay off is field selectable by
dip switches #5 and #6. However, dip switch #1 on the Inte- 5-ON 6-ON 50-100%
grated Furnace Control must be set to"ON"for cooling mode to
function properly. *-This setting is equivalent to BAY24XO45 relay benefit
The following table and graph explain the delay-off settings:
**-This selection provides ENHANCED MODE,which is
** This selection provides a ramping up and ramping down a ramping up and ramping down of the blower speed to pro-
of the blower speed to provide improved comfort,quietness,and vide improved comfort, quietness,and potential energy sav-
potential energy savings. The graph below shows the ramping ings.See Wiring Diagram notes on the unit or in the Service
process. Facts for complete wiring setup for ENHANCED MODE.
The graph which follows,shows the ramping process.
100%if necessary
80%
)�
Dehumidify
50% 50%
Fast Coll Cooling Efficiency
OFF OFF
1 I -7.5 I I S
minute minutes minutes
General Data o
TYPE Downf low/Horizontal VENT COLLAR—Size(in.) 4 Round
RATINGS 2 HEAT EXCHANGER
1st Stage Input BTUH 39,000 Type-Fired Alum.Steel
1 st Stage Capacity BTUH(ICS) 3 31,200 -Unfired
2nd Stage Input BTUH 60,000 Gauge(Firarf) 20
2nd Stage Capacity BTUH(ICS) 3 48,000 ORIFICES—Main
Temp.rise(Min.-Max.)'F. 35-65 Nat.Gas.Qty.—Drill Size 3—45
BLOWER DRIVE DIRECT L.P.Gas Qty.—Drill Size 3—56
Diameter-Width(In.) 10 x 7 UAUVA—Lw Redundant-Two Stage
No:Used 1 PILOT SAFETY DEVICE
Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition
CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot
Motor HP 1/2 Number 3
R.P.M. VARIABLE POWER CONN.—V/Ph/Hz ++: 115/1/60
Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 10.5
FLA 7.7 Max.Overcurrent Protection(amps) 15
COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 1/2
Drive-No.Speeds Direct-2 DIMENSIONS H x W x D
Motor HP PSC[Shaded Pole]-RPM 1/100/[11145]-2543/1727 Crated(In.) 41-314 x 19-1/2 x 30-1/2
Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 17-1/2 x 28-1/2
FLA PSC(Shaded pole] 0.70/0.40/f0.23/0.201 WEIGHT
FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 140/129
Type Recommended High Velocity
Hi Vel.(No.-Size-Thk.)Shipped 2-14 x 20-1 in.
0 Central Furnace heating designs are certified by the American Gas Association Inc.Laboratories.
O Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level.
O Based on U.S.Government Standard Tests.
0 The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes.
t
Customer Name
Comfort Advisor
SIG �u��E
Permit#: 1537
Permit Date: 07/05/17
Permit Type: RESIDENTIAL MECHANICAL
Project Nam e Pszonka
Applicant Nam a Nordstrom Heating &Air, Inc.
Applicant Address: 4717 87th Ave NE
Applicant, City, State, Zip: Arlington,WA98223
Contact: Debbie Elgin
Phone: 425-335-4029
Em al: nordstrom lu@com cast.net
Scope of Work: Replace furnace and add A/C
Valuation: 0.00
Square Feet: 0
Num ber of Stories: 2
Construction Type:
O xupancy G ioup:
ID Code:
Permit Issued: 07/07/2017
Permit Expires:
Form Permit Type:
Status: LASERFICHE
Assigned To: Kristin Foster
Property
Parcel# Address L egal Description O wner Nam e Caner Phone Zoning
PSZONKA RYAN M 116 Com m n Wall
00805600002500 7 915 210TH PL NE &APRIL Single Fam iy
Residence
Contractors
Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License#
NORDSTROM 1059 State Ave. CONSTRUCTION
HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR COA 601764617
NORDSTROM 1059 State Ave. CONSTRUCTION Labor&NORDSHA772L2
HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR Industries
Plan Reviews
Date R eview Type D escription A ssigned To R eview Status
07/05/2017 COMMIRCIAL z.Rick Karns
MECHANICAL
Fees
Fee D escription N otes A m cunt
Air Cond.Unit Btu/h<100>; $25.00
Btu/hp>500
Forced Air Heat f ee per Btu $25.00
Mechanical Base P erm i Fee $25.00
Processing/Technology $25.00
Total $100.00
Attached Letters
Date Letter D escription
07/05/2017 Building Permt
Paym arts
Date Paid By D escription P aym art Type A cceptcd By A m omt
07/06/2017 DANIEL NORDSTROM 6 5429535 c c $100.00
O rtstanding Balance $0.00
Uploaded Files
Date File Nam e
07/07/2017 2429366-1537 Issued Penn i.pdf
07/05/2017 2422799-1537 Specs.pdf
07/05/2017 2422737-1537 Application.pdf