Loading...
HomeMy WebLinkAbout8527 218TH PL NE_BLD1464_2026 Ay RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:8527 218th Place NE, Arlington, WA 98223 Project Description:Install heat pump and air handler to replace current heating system Owner: Chad and Nicole Matthews Address: 8527 218th PI NE City:Arlington State WA Zip Code: 98223 Phone: 425-308-9229 Email:Not Available Applicant: Foss Heating and Cooling I - Address:333 E Blackburn Road, Ste A City: Mount Vernon State WA Zip Code: 98273 Phone: 360-336-1517 Email: orders@fossheating.com CONTRACTOR INFORMATION Contractor Name•Foss Heating and Cooling Address:333 E Blackburn Road, Ste A City: Mount Vernon State WA Zip Code: 98273 License Number:FOSSHC19858A - Expiration: 11/1/2018 Phone:360-336-1517 Email:orders@fossheating.com STAFF USE ONLY Received Permit #: Accepted by: Date: MAY 12 2017 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE Heat Pump Model #Trane XR15 AFUE HSPE ❑ AC Unit Model # SEER Freestanding Stove Fire Place Insert QI Outdoor BBQ ❑ Gas Piping Solid-Fuel Appliance Other Gas Piping Information Not Applicable: F161 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 05/12/2017 Applicant Printed Name: Abrahm Joseph Rollins I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 107 wa� t�r C I ID tit s t. 2 2'asT29_ 2s --11—s I B `'7.5 k�X OAI Lek af^4 nJU. COIK 20 }Q tD Lfin no w m 22 22 i CITY CIF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:8527 218th Place NE Permit#: 1464 Parcel#:00943300000500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:MATTHEWS CHAD A Name:Foss Heating&Cooling Name:FOSS AND CO.HEATING Address:8527 218TH PL NE Address:333 E Blackburn Road Address:3233 E Blackburn Road City,State Zip:ARLINGTON,WA 98223-4662 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone: Phone:360-336-1517 Phone 360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:FOSS AND CO.HEATING Name: Address:3233 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: LIC'#: EXP: LTC#: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: I OC'C LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/IIER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 l0/IRCI I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the Ci of tt ton must be reported on your sales tax return form and coded City of Arlington 43101. A 1_ Signatiiic Print Name Date l Released By Date CONDITIONS Trane XR 15 -4TWR5030111000A-PERMIT CONDITIONS: 3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/16/2017 Mechanical Fee(Enter Fixture Fee) $50.00 5/16/2017 Mechanical Permit Base Fee $25.00 5/16/2017 Process ingrrechnology Fee $25.00 Total Due: $100.00 'Ibtal Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 8527 218th Place NE Permit#: 1464 Parcel#:00943300000500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:MATTHEWS CHAD A Name:Foss Heating&Cooling Name:FOSS AND CO.HEATING Address:8527 218TH PL NE Address:333 E Blackburn Road Address:3233 E Blackburn Road City,State Zip:ARLINGTON,WA 98223-4662 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone: Phone:360-336-1517 Phone:360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:FOSS AND CO.HEATING Name: Address:3233 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the Cit of r' ton must be reported on your sales tax return form and coded City of Arlington#3101. 1 Signature Print Name Date V y Released By Date CONDITIONS Trane XR15 - 4TWR503OH1000A - PERMIT CONDITIONS: 3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/16/2017 Mechanical Fee(Enter Fixture Fee) $50.00 5/16/2017 Mechanical Permit Base Fee $25.00 5/16/2017 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON, WASHINGTON --- BUILDING DEPARTMENT No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER:Chad & Nicole Matthews CONTRACTOR:Foss Heating and Cooling JOB ADDRESS:8527 218th Place NE OWNER ADDRESS: 8527 218th Place NE USE of BUILDING: SFR PLAT NAME: Eagle Creek Description of work: Install heat pump and air handler LOT# 5 PERMIT No: BLD-1464 Sprinklered: CONDITIONS:See permit DATE ISSUED: TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION 360-403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE The following documents will be required and must be available during the final inspection: Completed Public Works & Utility Inspection Card Final electrical sign off by L & I Completed Blower Door test certificate Completed Duct test certificate (if applicable) Conditions (if applicable) *indicates that the inspection is approved but there is a minor correction FINAL INSPECTION Required Documents: CORRECTIONS (* CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUQ.DING PERMIT Address:8527 218th Place NE Permit#:1464 Parcel#:00943300000500 Valuation:0.00 OWNER APPLICANT CONTRACTOR - Name:MATTHEWS CHAD A Name:Foss Heating&Cooling Name:FOSS AND CO.HEATING Address:8527 218TH PL NE Address:333 H Blackburn Road Address:3233 E Blackburn Road City,State Zip:ARLINGTON,WA 98223-4662 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone: Phone:360-336-1517 Phone:360-336-1517 1 �k N �`• '�11i�4 Namt:FOSS AND CO.HEATING Name: Address:3233 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-15 17 Phone: LIC#: EXP: LIC#: JOB DESCRIPTION ExP: PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST,TYPE: DWELLING UNITS: ( OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL HE EMPLOYED IN VIOLATION OF CIIE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL.FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE;AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI I0/IRCI I O. qAI S TAX NOTICE:Sales tax relating to construction and construction materials in the Cit of r' ton must be reported on your sales tax return form and coded City of Arlington#3101. L�,-1-7 Signature Print Name Date Released By Date COMMONS Trane XR15 -4TAIR50301-1I000A - PERMIT CONDITIONS: 3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. rH1S PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS.MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date DescriptionFee Amount 5/16/2017 Mechanical Fee(Enter Fixture Fee) $50.00 5/16/2017 Mechanical Permit Base Fee $25.00 511612017 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BU"ING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morninr or afternoon ,1 I - GITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address:8527 218th Place NE Permit#: 1464 Parcel#:00943300000500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:MATTHEWS CHAD A Name:Foss Heating&Cooling Name:FOSS AND CO.HEATING Address:8527 218TH PL NE Address:333 E Blackburn Road Address:3233 E Blackburn Road City,State Zip:ARLINGTON,WA 98223-4662 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone: Phone:360-336-1517 Phone:360-336-1517 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:FOSS AND CO.HEATING Name: Address:3233 E Blackburn Road Address: City,State,Zip:Mount Vernon,WA 98273 City,State,Zip: Phone:360-336-1517 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC1I0. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the Cit of r' ton must be reported on your sales tax return form and coded City of Arlington#3101. ' ,s Signature Print Name Date V Released By Date CONDITIONS Trane XR15 - 4TWR503OH1000A - PERMIT CONDITIONS: 3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/16/2017 Mechanical Fee(Enter Fixture Fee) $50.00 5/16/2017 Mechanical Permit Base Fee $25.00 5/16/2017 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon TANNE" Product Data Split System Heat Pump 4TWR5018H 1000A 4TWR5019H1000A 4TWR5024H1000A 4TWR503OH1000A 4TWR5036H 1000A 4TWR5042H1000A 4TWR5048H1000A 4TWR506OH 1000A I Note:"Graphics in this document are for representation only.Actual model may differ in appearance." August 2016 22-1832-14C-EN ( Ingersoll Rand 0 TRANE' Talb►le of Contents ProductSpecifications............................................................................ 3 Sound Power Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . ........ . .............. 5 Accessory Description and Usage . . . . . . . . . . . . . . . .. . . . .. . . . . . . . . . . . . . .. . . . . . . . .. . . . . . . . . .......... 6 Model Nomenclature........ .... . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . ...... 6 Schematic Diagrams.. ................ .. . . ... . . . . .. . . .. . . . .. ... . .. . . . . . . . . ........................ 7 OutlineDrawing ................................................................................. 11 Mechanical Specification Options............................................... ................ 12 2 22-1832-14C-EN 0 MANE' Product Specifications Model No.(a)(b) 4TWR5018H1000A 4TWR5019H1000A 4TWR5024H1000A 4TWR5030H1000A POWER CONNS.—V/PH/HZ M 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 12 12 14 17 BR.CIR.PROT.RTG.—MAX.(AMPS) 20 20 25 25 COMPRESSOR CLIMATUFF@-SCROLL CLIMATUFF@-SCROLL CLIMATUFFO-SCROLL CLIMATUFF@-SCROLL RL AMPS(d) —LR AMPS 9—56 9—56 10.9—62.9 12.8—67.8 Outdoor Fan FL AMPS 0.54 0.64 0.64 0.77 Fan HP 1/12 1/8 1/8 1/8 Fan Dia(inches) 19.1 23 23 27.5 Coil SPINE FIN'" SPINE FIN' SPINE FINTM SPINE FINTM Refrigerant R-410A(e) 6 LBS.,1 OZ 7 LBS.,4 OZ 7 LBS.,5 OZ 6 LBS.,13 OZ LINE SIZE—IN.O.D.GAS M(g) 3/4 3/4 3/4 3/4 LINE SIZE—IN.O.D.LIQ.(h) 3/8 3/8 3/8 3/8 Charge Spec.Subcooling 10OF 8*F 8°F 8°F Dimensions H x W X D Crated(IN.) 30.1 x 30 x 26.7 38 x 33 x 30.1 38 x 33 x 30.1 34.4 x 38.7 x 35.1 Weight—Shipping(lbs.) 161 196 208 248 Weight—Net(lbs.) 141 162 174 216 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT004 Start Kit BAYKSKT263 — — BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 BAYLOAM107 Refrigerant Lineset 00 TAYREFLN7* TAYREFLN7* TAYREFLN7* TAYREFLN7* Sound Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Service Valve Panel Cover TAYSVPANL0022AA TAYSVPANL3343AA TAYSVPANL3343AA TAYSVPANL0032AA 0) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size.The value shown is the branch circuit selection current. (e) This value approximate.For more precise value see unit nameplate. (1) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines.Reference the refrigerant piping software pub#32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications(xx denotes latest revision). (9) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet oftested connecting lines.If connecting line length exceeds 15 feet,then final refrigerant charge adjustment is necessary.Each additional foot over 15 feet requires 0.6 ozs of refrigerant.See the Installer's Guide for full charging instructions. (h) This value approximate.For more precise value see unit nameplate. (1) *=15,20,25,30,40 and 50 foot lineset available. 22-1832-14C-EN 3 0 7RWE Product Specifications Model No.(a)(b) 4TWR5036H1000A 4TWR5042H1000A 4TWR5048H1000A 4TWR506OH1000A POWER CONNS.—V/PH/HZ M 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 18 22 24 32 BR.CIR.PROT.RTG.—MAX.(AMPS) 30 35 40 s0 COMPRESSOR CLIMATUFF@-SCROLL CLIMATUFF@-SCROLL CLIMATUFF@-SCROLL CLIMATUFF@-SCROLL RL AMPS(d) —LR AMPS 14.1—72.2 16.7—109 18.5—124 23.7—152.5 Outdoor Fan FL AMPS 0.64 0.93 0.93 2.80 Fan HP 1/8 1/5 1/5 1/3 Fan Dia(inches) 27.5 26.6 27.6 Coil SPINE FIN— SPINE FINTM SPINE FINTM SPINE FIN— Refrigerant R-410A(e) 8 LBS.,14 OZ 10 LES.,5 OZ 10 LBS.,9 OZ 10 LBS.,9 OZ LINE SIZE—IN.O.D.GAS(F)(9) 7/8 7/8 7/8 1-1/8 LINE SIZE—IN.O.D.LIQ.(h) 3/8 3/8 3/8 3/8 Charge Spec.Subcooling 10°F 8°F 8°F 8°F Dimensions H x W X D Crated(IN.) 42 x 38.7 x 35.1 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 38.7 x 35.1 Weight—Shipping(lbs.) 246 277 300 301 Weight—Net(lbs.) 199 227 250 251 Optional Accessories: Anti-short Cycle Timer TAYASCTS01A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM10/ BAYLOAM103 Refrigerant Lineset(1) TAYREFLN7* TAYREFLN7* TAYREFLN7* TAYREFLN3* Sound Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Service Valve Panel Cover TAYSVPANL0044AA TAYSVPANL0044AA TAYSVPANL0044AA TAYSVPANL0046AA W Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with N.E.C.Only use HACR circuit breakers orfuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size.The value shown is the branch circuit selection current. (e) This value approximate.For more precise value see unit nameplate. M Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines.Reference the refrigerant piping software pub#32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications(xx denotes latest revision). (e) Ti di e uulUuui wndensiiiy units dt a rdLlui y Llidtyed willi llie system Ll mi ye i eyuii ed rui Uie uulduui wndensiny ui A and 15 feet of tested connecting lines.If connecting line length exceeds 15 feet,then final refrigerant charge adjustment is necessary.Each additional foot over 15 feet requires 0.6 ozs of refrigerant.See the Installer's Guide for full charging instructions. (h) This value approximate.For more precise value see unit nameplate. 00 *=15,20,25,30,40 and 50 foot lineset available. 4 22-1832-14C-EN 0 TAWE Product Specifications Sound Power Level Sound Power Level A-Weighted MODEL Sound Power Full Octave Sound Power(dB) Level[dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TVVR5018H1 73 72 66 64 66 71 64 56 47 4TWR5019H1 74 72 69 63 70 70 67 56 49 4TWR5024H1 71 77 72 68 68 69 60 53 47 4TWR5030H1 72 77 72 69 68 65 60 57 52 4TWR5036H1 70 75 69 68 68 66 62 57 51 4TWR5042H1 72 77 75 72 70 67 62 59 52 4TWR5048H1 72 77 75 72 70 67 62 59 52 4TWR5060H1 72 77 75 72 70 67 62 59 52 Note:Rated in accordance with AHRI Standard 270-2008*For Reference Only 22-1832-14C-EN 5 aMANE Accessory Description and Usage Anti-Short Cycle Timer— Solid state timing device that prevents compressor recycling until five(5)minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery,commercial applications,long lineset,etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions.Used for low ambient cooling to 30°F with TXV. Rubber Isolators— Five(5)large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad.Use on any application where sound transmission needs to be minimized. Hard Start Kit—Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply,on long linesets,low ambient conditions,etc. Extreme Condition Mount Kit— Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds,or on commercial rooftops,etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB,67°F WB air entering indoor coil,95°F DB air entering outdoor coil. 2. High Temperature Heating 47eF DB,43°F WB air entering outdoor coil,70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions— (Noise rating numbers are determiend with the unit in cooling operations.)Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 1 2 3 4 5 6 7 6 9 10 1112 13 14 15 4 T W V 0 0 3 6 A 1 0 0 0 A A Refrigerant Type 2=R-22 4=R-410A TRANE Product Type W=Split Heat Pump T=Split Cooling Product Family V=Variable Speed M or B=Basic Z=Leadership-Two Stage A=Light Commercial X=Leadership R=Replacement/Retail Family SEER 3=13 6=16 0=20 4=14 8=10 5=15 9=19 Split System Connections 1-6Tons 0=Brazed NnminRl Capacity in nuns of RTI Is Major Design Modifications Power Supply 1=200.23011160 or 208-230/1/60 3=200-230/3/60 4=460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 6 22-1832-14C-EN ap0 AINE' Schematic Diagrams Figure 1. 019 and 024 Models THERMYLT LEGEND I � —_f FA oM Imuuu 0 to Ir 2N Y t CPR _ N U`R V'rN1KNrrrr � LINF I�FACTNI _—_—_—_— FACTOR r OR .EtNAW'Y LINE FIELD i MIRING q - ---- FIELD INSTALLED ur WKrm FACTONV FIRING tt • 'W nur �r MAGNETIC COIL r< Ic,IKp nr v GROUND Ur lI KK i tt.I htlrlM�I Ru w.r csrY • JUMCTIOU IMON FY K41 �� CAPACITOR rte.. uW Iran tnttl p FIRE NUT OR I .h .S WON rRn(tlp 0 TERMINAL IK IN WIRW tn41 NIRU � a a t1MKRW rea.NnKM11 V TRANSFORMER CMAC I I011 r1 amAa1 rK M 11I FUSE t t OIt101.RrIYtr1 KYY ❑ TEAM)NAL GLOCX/SMRO i p4 I'••UM•.�lq MR NntM1 Wugrrr .YYY,[ KIIW rrryn �� RTIAI CONTACT K to M R.W.run Wtri1 . RELAY CONTACT(N.C) Nt KKtWc aNrtw�Ott N TNERNISTOI I rl 1q !Ir r�rK�n rr.I� .n ur I M$ ry rtlr,rlrtwm ( nL ------- ,K . Wr�u rirrM W.r TENP ACTUATED SNITCH eL �taNrIIN �D INTERNAL OVERLOAD PROTECTION I L! —LI I I W�iN ._S` BX/BL 6 PRESSURE ACTUATED SNITCH �aN s Mrm a q SIRiuR N RN H qm �A,AH RESISTER OR HEATING ELEMENT n rIIF i�n 111111 Q"'D MOTOR FINDING I pJf IL I °` I F?TTTTI POL.PLUR FEMALE HOUSING A PdSIYi/IINLE TERMINALS) I ON et PN.PLUS MALE MUSING rR _ (FEMALE TERNINALSI i I INOT S` I csR I, BE SURE POWER SUPPLY AGREES WITH EOUIPNERT RAMFPLATE. I J I I 2. POWER MIRING AND RUNNING OF ENIPPENT MST COFLY WITH LOCAL LODE.. 3. LOU VOLTAGE MIRING TO BE NG IS AND■ININHI CONNCTOA I r� GR YI .. OpR-S Nulr RE It,IOMR:w.1.A rye/ F IL T Lj i t E•usl Blt O'�OBN-, &WARNING LI N1 RA.�[1A.tlRr.WrIIdrE rICYrNIlMc T lAGItlIK EI IRTALL IL—H.-MN PIoI n B N I.ROME in .f A//A OIIu 1'I I�, ' I c.n r.n1 rnn. I Irrrrtal I11.rY.r Na11, -----� ___- __ IA ----d/ ---____ I &CAUTION � T�NRRIAuillnrnaRmiirm X2 TFD�7"•o_ro '_'-'--"_ < I //``�� Y i tY uuNlu inrrullou _----O"Lpp ___ _ —_ __ — _—_—_—_—_—_ _—_—_—_-- Ir tY11N�Mt InflNGt rq M(q ----y� YL �r�N hNlq IKIEnM n'IRA�Yq i �•` TO TONER YATLY PER IRCq RgiM OgIINT PY MI -----R-• NO eN UNIT NAMEPLATES AXD InYKUTION N Kq N IN F• /''L LOCAL CODES LA TEIIF _--- Y2� PRINTED FROM D158595PO2 REVA 22-1832-14C-EN 7 0 Schematic Diagrams Figure 2. 018,030 and 036 Models \ �� Spy TNERMALLT Dn/at x ir—VL 441 1 N l LEGEND r—_ 4J f N R IntnnLT n .R LLRn nl zA r 0 u rK ruA[Im N IIA�L utrtl[IN -- YILINEY IFELD �� Y I RRIM r CKKITMI ----- FIE INSTALLED IrtIM wllrr FACTWT KIRINR 111 r IMrl1r rlltrlM wtp �r MAINETIC COIL 1 r SRWND r u. Wr I II/ 1 ILIRrIr 1p WrrPrq • JUNCTIW M a IFK IMr �F CAPKI TM rt1 1 rNrl 4rR KItP p KIRE NUT N u P rrrrW 4q> CNR O TERNI NAL ari• mrNlr Nr tPfrlN TRANOFORMEN S «� CAPACITOR u1 r*wu•u+1lwtct �r FUSE I Y NoHGI InwI1mI tt+turwrlmw• ❑ nRKfMa �n�Lr.r LAI Cp?"T TKT'*q.Oj -IF- -IF- K 01 I 1 R RIRu lYt1 rMR Ianr1Y RELAI CONTACT IN.CI _ O 4 TRERNISTOR r •wu1 LLu TnIR���/K1fd I \B'L Att r .K.Ir urli�n<Pnn to.r R`--"P IN ---- IS INTERIM OVERLOAD PROTECTIONI tt I I K L� IS _t K BRIBIL ,Ai1tW["NATEO Irlltw team v Yr1 _R-yf-p SEE SEYYIOE FKrN 1 _— R M BLUE L[ w�I yyt� RESISTER OR NEATIAN ELEMENT FCA O"INUl STNT I OAIOI ' IT g Ill n rt N RILL I NIT ACCERIONY E Kl n Via 0--b MOTOR•IID," « « I KS R ff,,II 44II 1YA..PLYY tLMAIL NU IIIIb I r__ ---- ^ F VOILE TERMINALSI Oi eK el ' f_I 1prprq POL.FLN MALE XWRIRO 1 r _ 1W/IFEMALE TERYIMALAI MOTFS: I I I. K Sm INNR-Phl KKIA'IN tNIRMrr AAYIAATt C6q�I i L _� 1 E. Tdll•rIN Aq Almmlr or[WIPKR wyr cNnr rIr• ' LOCAL OPEN. 1 + 1. IN IK IML r111K 10 I(•R. 11 AK FIIIYq CORUKIN. I 1 i r 1 1 GR IL /. WT-B NOT BE SET LWER TUN WT-A I 1 II t5� L�.� I BNo SOBN-I I I �IIARN I NG oA BI. i �a•.or IMILL I MTMItrI rOLT1At1 ' I UN ul n1YlAl41 rill ;B ODN `Kro IN�oR IIKANIu! i1 1 N. 1 F7 r•It Ilr•IrIr1I PNR 1 1 Yur 1.1,1 Illurl•r 1•rlY. —� mCAUTION 1 b r I Irf.t—-11 lIK1LL•MI AK NIINLI XZ k....... TO V!KRI TIRI K ImRIK+mI '•Il�r I•Y prl e••1.Ira ----8�' pIWI — �n fmfYNIN IRIUAtIN1 _��_ � �_� _ � �� � _�_�_�_ _—_—_—_---_—_—. 41 IN:AK ruK11 r•l ala _--_ YI' LTE f Itl _J11tNIIN.K OORI41 FM W ---- TO PDNAM SNRI AEA I.-K R 1 K 1.I• n IL UNIT NAMEruIE•AND LA TEBBE Y LOCAL [DIES PRINTED FROM DI58595P01 8 22-1832-14C-EN 0 7XWE' Schematic Diagrams Figure 3. 042 and 048 Models t ' �Ip,(Q, PR TEILLI RA/OLD. j -1i 1J F° �IRi��C.T.ED. LEGEND y"+ — J� () E MT _ R CM zA r�ly FRICTION,t« t�rLwA0ltrlUlm � LINE9OIRINI r —_— —_—_— F Wrc tr,atr LIRE If FIELD1. i cOIP,010A w WA wYIm ----- FIELD INSTALL ED r FACTMY ,-L MA/NET IC DI we wrlpn IrUOL L IRgIND ww i IfY flltnrlt lw lYw(ri..l • JUACTI011 IrOv/r uUl �F CAPACITOR PRU—I—IN, p ■IRE O TERMIN A NDTL OR .<•WIYAr..Aw<1r ��� r[CIMr n.tt. I 1 rs.Lur «.rcw uwwwl TRANSFORMER w m.-URA r"-'I I CAPACITOR ulra/r+r•rm "'- I— I r R01 OR aloaa ronur.0 IHM El rnu.0 urcu3aup I \ yw:R.r t.l•.M1<' RELAY CONTACT n.01 � m YnYr n.rl.u, �F wo.Yw MUp1A �. AlLAI CONTACT I•,CI _ 1'ttrc dYl wr�r/r+� I - cuMlr.It./I,.R.n.r«I TXERMISTOA I71 II r r m. MS r n.Y.rvfrrm TEMP ACTUATED SWITCH I {L 2 RUN , —'"-----'—'— 1 rY. .Ir wY�<r trllY..1.. ,-caw OF H. �b IIriN.Al Or[-LOAD 14-TTCIIDY I I lE LI I I A—y ; ( x tOOLn IF-1. OLD rAnEDAE XTwnO n11CM I • a W,I r „ .1 h SEE SERVICE NEAR r { 1—p i „ cA yy�.-REI I6TER W HEATING ELEMENT TO OPTIMAL TIME {Nz{L T� /I/IN a Lu W rITF r I.P. ' M,MN, n All•r l Omro MOTOR OINDINI I MIT ACCEENgT I W Pw ��- - - I N3 « I POL PG FEMALE 13�IMAILU E TERMIXALSINDUSI NO I 1 - {{ {L r 1 POL PLUS IDLE HOUSING1 _ IFEMALE TERMINALS i I f DFC BOARD I — I NOTES: IN I I, Of USE—,WRr—(1$111.Iarl P•ur a.wrurt. I i L _J � 2. POWER WINING AND 6AWNOIN/OF EQUIPMENT MST COMPLY WITH I LOCAL CODES. , r� ; — n a 3 LOW rOLTA1E NIRIW TO BE NO IS AN MINIMUM CONDUCTOR j � YL rc OR YL "� 1 I I. a/t-N Nu AL III IGrN 11.om.A 1 �_---'-- _ -J I ----< --OOT:N�•AtlD r1 BN oex , It WARN INO 011 {L I A .1'U'COf VOLTA/EI 1 I .IRan ccr SIOAnY POLAN [f OBN IWL.DI / r USS'TE.Ircw•RA fB' ' r 1 r � F N[w dl.[rnIt P.— b,l.r•..r.l<I.R<..<.......... pw.r.l I.f.rT or A,.R. -----J --- -- ---- -----1 I--- -- --- ACAUT I ON (] 'icnm onNL n mr,nr, ° M --- - -- -- -- ----------- -—-—-—-—-—-—-—- ITS L n trl.«,rl unlrl r«.u« n,rtr rrcmlr Ir.-mrw.E G Q .Itnll«a A«.Ilr 1 TO PONAM PLATES PER wn=1 NEnarfWr. � UNITXANEPLAT[9AND PAINTED FROM D159478P01 AEVA LA T[AAE __-- Y2Q LOCAL CODES 22-1832-14C-EN 9 0 TRWN' Schematic Diagrams Figure 4. 060 Models LEGEND � -�1,p�MN�a eA/eL'�'•"'At r--limp, (�U9 VARIADIE L1 L.__1 SPEED Q OD FAX CPR ,/ NOIOR a W AMIIIIA Et Y 1FK70RT W HPPI M�twww[wN LIXE YJ 11I11ING nrtltgw[tw «« LINE Y)FIELD MwA MIRING CA AY CAKITw FIELD IXITKLED I ' <[ n•Nrw WDtlrs ----_ FACiMIY MINING <Y Wrra wlegrr u[rr MAGNETIC COIL IF, wFAert eslwl MAWXD m U. 11 W rMn 'L rc YK m ruw mtn • JUNCTION rYV rrAelA� rtt r �F CAPKITOR i .rrs« LAvt rear FnI 0 WIRE NUT DA irm Is'Murrlrrn•�rrrnr O TERMI XRL cal V•qrq cgirfq TRAXSFORNER I ry1 ar rro rr u+.�[•aai FUSE .rDq rtrPHnrAr mrI• ❑ TERMINAL BLOCK/NOAGD rDt rYr nrwrur [our yr IIIII(M[ rY­0KI r WlHrrat �rUN tart rDnM qna ' I11AI(gtKl rN.tl nMIWf t6r mgmn �/�\ THERN14TOR i :NS T rMEA.. r t„517. T. TO nr wRwwliwF nut TEMP ACTUATES I•I1CH I� ---------- rrncmrL II T���i-D Y �wwHT R M IIY �� INTERNAL OYEALOAD PROTECTION I OL 7 l Rai ; 1 INON/BL�wMNY.[A IAEUW[ACIDATED WIICX I 8 --- rwrL[AG A. AD twit N[I REGISTER ON HEATING ELEMENT Fit/tHllt FKi6 K tlA Y- TII/ eww rt iciw 1p NY 0.IT", I I .� w PIr I NIT KC1Uw1 U"""b MOTOR MINDING AT IL I I MAi EL. TERM INALLE1 --_ 1ppYpp(�p�POL.PLUG MALE HOUSINGS I 'rON 0L I r 1111IL IFEMALE TERMINALS) ;I I— AGT I 'II _ i DFC BOARD AI LLL[rowL I'll,—tit•11N[D1tIwY NAwfI AT[. I CSR i. POKER MINING AND DAWNOIAG ai fWI1MEA7 MUST COMPLY MITX r I I LOCK C0DE6, r 6. LOW VOLTAGE MINING TO KE NO.IN M MINIMUM CWNCTON. i I I. oet a MUtt e[ACT LORA nM-A I �GR YL � J i L BKrfoDN r i AWARNI NG OR DL I 1OO110TION& L HAKAN0W6 VOLTMEI ;8Ql0 BK j IMLLW N YIDt[D.—I. ■FM[1[rtIDI At Q I I r 1 Mlerrr DlrAl c,n e[icl[Pr•1rAPHED ---_J ._ __ ____ ____ r Aural IrJN T n MHII• ___ r I ACAUT I ON GMT TT 'r NN el e ITS CANADIAN I-lb.— _— — OR PONGI LIYTIw:YOr SUITABLE fw Wf a Y' AT6IEYA EICE[DIM rYrwiA•w> TO POKER SUPPLY PER Arr[Atlw�w(green 1u A.r KN UNIT NAMEPLATES AND ZALLAi1404 D[1—It rY.. Y2Q LOCAL CODES PRINTED FROM D SB596P01 LA TENA[ ---- 10 22-1832-14C-EN 0 TRANE° Outline Drawing a SERVICE PM[L ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRE 5TRICTED FOR AT LEAST 152N 15 FEETI ABOVE UNIT UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIREC FLY ON UNIT. AND SHOULD BE AT LEAST 305 112'I FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED ELECTRICAL SERVO C[ PANEL K 25 11I A 22 2 1T/8I DIA. IIOIC LOW VOLTAGE 2B 6 I -I/81 DIA. N . 11 22.2 I NCII DIA.MOLE IN.00ONWICAL BOA BOTTOM FOR ELECTRICAL POWER snPPIT H F N.O. 101 ALTERNATE 0 ELECTRICAL ROUTING LIOCIO LINE SERVICE VALVE. 'F' L.D. TENAL[BRAZE CONMCCIIOR WITH It SA( GAS LINE I/1 TURN BALL SERVICE YALYE. 'D' FLARE PRESSURE TAP FITTIIIGS- IL.D FEMALE BRAZED CONNECTION WITH I/A' SAE FLARE PRESSURE TAP FITTING Model Base A B C D E F G H J K 4TWR5018H 2 730 724 651 3/4 3/8 127 57 194 38 457 (28-3/4) 28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18) 4TWR5019H 3 832 829 756 3/4 3/8 127 76 197 60 508 (32-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4TWR5024H 3 832 829 756 3/4 3/8 127 76 197 60 508 (32-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4TWR5030H 4 741 946 870 3/4 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-3/4) (20) 4TWR5036H 4 943 946 870 3/4 3/8 143 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (5-5/8) (3-7/8) (8-5/8) (3-3/8) (20) 4TWR5042H 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 4TWR5048H 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 4TWR5060H 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) 1 (3-3/8) (32) 22-1832-14C-EN 11 0 rA WE' Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping.This unit is designed to operate at outdoor ambient temperatures as high as 11YE Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The corner panels are prepainted.All panels are subjected to our 1,000 hour salt spray test.The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan,compressor contactor and high pressure switch.High and low pressure controls are inherent to the compressor.Afactory supplied liquid line drier is standard.Some models may require field installation. Compressor The compressor features internal over temperature,pressure protection and total dipped hermetic motor.Other features include:Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured,this system has a cooling capacity to WE The addition of an evaporator defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Thermostats—Cooling only and heat/cooling(manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. c usris"ZI CERTIFIED s en Intertek Globally Recognized.Industry Respected. � rJt WE Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Caro,Ingersoll Rand@,Thermo King@ and Traneo—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. For more information,visit www.ingersollrand.com. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the rightto change design and specifications without notice. The AHRI Certified mark indicates Ingersoll Rand participation in the AHRI Certification program.For verification of individual certified products,go to www ahridirectory.org. ©2016 Ingersoll Rand All rights reserved 22-1832-14C-EN 12 Aug 2016 ��// Ingersoll Rand Supersedes 22-1832-14B-EN (June 2016) T Y a� RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:8527 218th Place NE, Arlington, WA 98223 Project Description:Install heat pump and air handler to replace current heating system Owner: Chad and Nicole Matthews Address: 8527 218th PI NE City:Arlington StateWA Zip Code: 98223 Phone: 425-308-9229 Email:Not Available Applicant: Foss Heating and Cooling Address:333 E Blackburn Road, Ste A City: Mount Vernon State WA Zip Code: 98273 Phone: 360-336-1517 Email: orders@fossheating.com CONTRACTOR INFORMATION Contractor Name:Foss Heating and Cooling Address:333 E Blackburn Road, Ste A a City: Mount Vernon State WA Zip Code: 98273 License Number:FOSSHC19858A Expiration: 11/1/2018 Phone:360-336-1517 Email:orders@fossheating.com STAFF USE ONL Received Permit#: Accepted by: IV Date: MAY 12 2017 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL s a PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑; Furnace (80+) Model #_ AFUE [� Heat Pump Model #Trane XR15 AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance Jl Other Gas Piping Informatlon Not Applicable: (� Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve in�s required within 6 feet of all appliances Applicant Signature: Date: 05/12/2017 Applicant Printed Name: Abrahm Joseph Rollins I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 wa 107 80 e sF. '355 3D 11 2 --11 �7.3 RFX 4yd Ok -44 F,,� Z44l 2D BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 1464 Address: 8527 218th Place NE Contractor: Foss Heating & Cooling Owner: Matthews Date: 5/23/2017 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Heat pump &Air handler CO DETECTOR: ® HEAT PUMP/AC UNIT: GAS PIPING: ❑ DISCONNECT: DRIP LEG: ❑ SEISMIC: VENTING: ❑ 3" PAD: ACCESS: ® INSULATION/PROTECTION: SHUT-OFF VALVE: ❑ DUCTS: N/A L&I: Yes Date: 5/23/2017 Inspector: Kevin Olander Permit#: 1464 Permit Date: 05/16/17 Permit Type: RESIDENTIAL MECHANICAL Project Nam e M Ithews Applicant Nam a Foss Heating & Cooling Applicant Address: 333 E Blackburn Road Applicant, City, State, Zip: Mount Vernon,WA98273 Contact: Phone: 360-336-1517 Em al: orders@fossheating.com Scope of Work: Install heat pum pand air handler to replace current heating system Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 05/16/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Launa Black Property Parcel# Address L egal Description O wner Nam e Ovner Phone Zoning 00943300000500 8 527 218TH PL NE MATTHEWS CHAD 111 Single Fam iy A Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# Foss Heating and 333 E Blackburn CONSTRUCTION Cooling,Inc 360-336-1517 Road CONTRACTOR Labor&Industries FOSSHCI9858A Inspections Date I nspection Type D escription S cheduled Date C om lieted Date I nspector S tatus 05/23/2017 R00.HEAT PUMP/ 05/23/2017 B UILDING A pproved AC UNIT FINAL Plan Reviews Date R eview Type D escription A ssigned To R eview Status 05/16/2017 RESIDENTIAL z.Rick Karns MECHANICAL Fees Fee D escription N otes A m aunt Mechanical Fee(Enter Fixture Fee) $50.00 Mechanical Base P erm i Fee $25.00 Processing/Technology $25.00 Total $100.00 Attached Letters Date Letter D escription 05/16/2017 Building Perm 1 Paym arts Date Paid By D escription P aym ait Type A ccepted By A m aunt 05/16/2017 Abrahm Rollins 6 4737829 c c $100.00 O itstanding Balance $0.00 Uploaded Files Date File Nam e 05/24/2017 2310502-8527 218th Place NE.docx 05/16/2017 2290603-1464 Issued Perm i.pdf 05/16/2017 2289630-1464 Application.pdf