Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3609 176th Pl Ne_BLD340_2026
/4/4 a �, CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3609 176th PI Permit#:340 Parcel#:00598900003000 Valuation:0 00 OWNER APPLICANT CONTRACTOR Name:NEILL STELLA Name:Washington Water Heaters Name:WASHINGTON WATER HEATERS INC Address:3609 179TH PL NE Address:1800 Richards Rd,Ste A Address: 1800 RICHARDS RD STE A City,State Zip:ARLINGTON,WA 98223 City,State Zip: Bellevue,WA 98005 City,State Zip:BELLEVUE,WA 98005 Phone: Phone:800-978-8588 Phone:(800)978-8588 EXT: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:WASHINGTON WATER HEATERS INC Address: Address: 1800 RICHARDS RD STE A City,State,Zip: City,State,Zip:BELLEVUE,WA 98005 Phone: Phone:(800)978-8588 LIC#: EXP: LIC#:WASHII*9800P EXP:9/17/2014 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: _ PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING;CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/[RC1 I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington m st be reported on your sales tax return form and coded City of Arlington#3101, 1 Signature Print Name Date 1 ased By Date CONDITIONS THIS PERMIT AUTHORIZE ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount Total Due: $0.00 Total Payment: $0,00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �) i I �` I electric water heater 1 42-32656 . page 1 01. Selection 42-32656 iTank Capacity 55 Gallons Number of Elements per Unit _ 2 Upper Element Type Limeguard Lower Element Type Limeguard DualWatt Anode 1 Dip Tube PEX Roto-Swirl Tank Material Glass-Lined Steel Insulation Material Foam Insulation R Value I 16 Insulation Depth(Inches) 2 17.3 G.P.H.@ 3,800W Recovery at 90 Degree Rise 25 G.P.H.@ 5,500W 61 Gallons @ 3,800W First Hour Rating 64 Gallons @ 5,500W Voltage 1 240 Volts Kilowatt Hrs.Per Year 4.879 Wattage at 240V 5,500 Watts Maximum Fuse Required 30 Amps Minimum Wire Size i 10 Gauge Alternate Dual Power Wattage at 240V 3,800 Watts Maximum Fuse Required 20 Amps Minimum Wire Size 12 Gauge Est.Yearly Operating Cost I $520 Shipping Weight(Approx.Lbs.) 130 Dimensions(inches) Maximum Height 60.25 Kenmore 55 Gallon Tall Power Miser 6 Height L 60.25 Electric Water Heater Width 20.50 42-32656 Depth -- 1- 20-50 Diameter 20.50 • Factory-Installed temperature and pressure Warranty safety valve 1-Year Limited Warranty— • Limeguard elements resist lime build-up Entire Appliance Labor and lasts longer than standard elements 6-Year Limited Warranty I Tank&Parts If used for other than private family purposes,warranty applies for • DualWatt lower element easily converts only 2 years. from 3,800 to 5,500 Watt operation to fit the customer's wiring • Cobalt Blue Ultra Coat Glass-Lined tank with single anode rod for tank protection r � � Ij ii)iN i • Energy efficient foam insulation • Roto-Swirl self-cleaning cold water inlet tube _r OV Ui+." rS3 AFC'-r-Vi!')C',Y T;;_ a 3ecause of cvr con^L*.s ryog`am Cr P,cdud rrpae ne^t�re I.ntca by Sears �t_a"«ci tlrlryl•ta>.;tlarxp•nei:'�al:,z"d rzx:h::t3tMX'!:'Mlhni U� u•art..t;tr.. Effective . •`0t�(.bns.I'i^s:dlat C^nsvxtionspadk9Cwtr gheprocictOr ® c•b„at,.t;r. ^ (,OIT1fflBtCldl final dimerSeral data.For complete weranly inrc,malior,corlac: yo-•local&-e u O)mmcrccal Accuurt Ma•iagcr. i� L� -� RESIDENTIAL PLUMBING / MECHANICAL PERMIT APPLICATION Department of community& Economic Development e ® City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING/MECHANICAL INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 13609 176TH PL NE Project Description: REMOVE & REPLACE 1 ELECTRIC WATER HEATER IN GARAGE Owner ISTELLA NEILL Address: 13609 176TH PL NE ARLINGTON WA 98223 E-mail: N/A@NOEMAIL.COM Phone (h) 425-760-3279 (c) 206-963-9761 Applicant: IJACCI DANIELS Address: ISAME AS CONTRACTOR Phone (h) 800-978-8588 (c) E-mail: Contractor Information Contractor Name: IWASHINGTON WATER HEATERS Company: IWASHINGTON WATER HEATERS Address: 11800 RICHARDS RD, STE A, BELLEVUE WA 98005 License Number: WASHII*9800P Expiration: 9-17-14 Phone: 800797878 8_8 E-mail: IHOTWATER4YOU@YAHOO.COM Plumbing Section (select all that apply) i �, 1 � Bath/Shower Combo (4.0) Sink (1.5) Shower (2.0) Lavatory (1.0) Clothes Washer Water Closet (2.5) Dishwasher (1.5) Q Water Heater 1 Hose Bibb (2.5) Other (list) Proposed Water Piping Size: Proposed Piping Material: Proposed DWV Material: J Proposed DWV Size: •All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 •All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: El Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances •A shut-off is required within 6 feet of all appliances Please Attach Site Plan and Supporting Documents (PDF Only) Neill water heater specs.pdf t BUILDING INSPECTION REPORT — PLUMBING (HWT) Permit No. 340 Address: 3609 176th PL Contractor: Washington Water Heaters Owner: Neill Date: 5/1/2014 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Electric Water Heater LOCATION OK: © L&I: EXPANSION TANK: ® SEISMIC: INSULATION: ® VENTING (6x6 collar): ❑ 18 INCHES OR FVIR: ❑ PRV 6 INCHES: PRV SET < 210: M PRV < 150PSI: DRAIN: © DRIP LEG: ❑ IMPACT PROTECTION: ❑ ACCESS: SHUT-OFF VALVE: ❑ COMBUSTION AIR: ❑ Date: 5/1/2014 Inspector: YOUNG Permit#: 340 Permit Date: 04/03/14 Permit Type: RESIDENTIAL PLUMBING Project Name: Stell Neill Applicant Name: Washington Water Heaters Applicant Address: 1800 Richards Rd, Ste A Applicant, City, State, Zip: Bellevue,WA 98005 Contact: Jacci Daniels Phone: 800-978-8588 Email: hotwater4you@yahoo.com Scope of Work: Change out electric water heater Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 04/16/2014 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00598900003000 3609 176TH PL NE NEILL STELLA 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# WASHINGTON WATER JACCI DANIELS (800)978-8588 PO Box 59208 CONSTRUCTION Labor&WASHII*9800P HEATERS INC EXT: CONTRACTOR Industries Fees Fee Description Notes Amount Water Heater(Tank) $25.00 Plumbing Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 04/03/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/16/2014 JACCI DANIELS 49953051 cc $50.00 Outstanding Balance $0.00 Uploaded Files Date File Name 07/28/2014 340 E.Burke.docx 05/05/2014 3609 176th.docx 04/03/2014 BLD 340 Application.pdf 04/03/2014 BLD 340 Specs.pdf