Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20429 81ST DR NE_BLD1433_2026
RESIDENTIAL PLUMBING PERMIT APPLICATION ING�� Department of Community & Economic Development City of Arlington• 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address.20429 81st Drive Northeast Project Description:INSTALL 40 GALLON HWT IN GARAGE Owner: MICHAEL SHREEVE 20429 81st Drive Northeast Address: City:ARLINGTON State:WA Zip Code: 98223 Phone: (206) 484-5956 Email. m_shreeve@yahoo.com Applicant:CM HEATING Address: 1415 BROADWAY City:EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: MEREDITH@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address: 1415 BROADWAY City:EVERETT StateWA Zip Code-98201 License Number. Expiration Expiration:5/3/17 Phone-4252590550 Email. MEREDITH@CMHEATING.COM STAFF USE ONLY Permit #: Accepted by: Date REV 2015 Page 1 of 2 RESIDENTIAL PLUMBING PERMIT APPLICATION ING�� Department of Community & Economic Development City of Arlington• 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Plumbing Section (check all that apply) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x ❑ Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1 .0) x ❑ Clothes Washer (4.0) x ❑ Water Closet (2.5) x ❑ Dishwasher (1 .5) x Q Water Heater x 1 ❑ Hose Bibb (2.5) x Water Heater Model # ❑ Other (list) x RG240T6N Proposed Water Piping Size: 3/4" Proposed Piping Material: COPPER Proposed DWV Material: B VENT Proposed DWV Size: 3" • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Applicant Signature: Date: 04/19/2017 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. REV 2015 Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:20429 81st Drive NE Permit#:1433 Parcel#:00825100001200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:HANSON AUDREY KATHLEEN Name:CM Heating Name:CM Heating Inc Address:20429 81ST DR NE Address:1415 Broadway Address:1415 Broadway City,State Zip:ARLINGTON,WA 98223-5969 City,State Zip:Everett,WA 98201 City,State Zip:Evcrett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:CM Heating Inc Address: Address: 1415 Broadway City,State,Zip: City,State,Zip:Everett,WA 98201 Phone: Phone:425-259-0550 LIC#: EXP: LIC#:CMHEAMH877DN EXP:03/15/2019 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL 1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBCI IOARC110. SALES TAX NOTICE:Sales tax rclatin to construction and construction materials in the City of Arlington re rted on your sales tax return form and I City of Arlingt n# 1 ►�' ��� •I � 20.Zo1`�1 Signature Print Name Date I By Date CONDITIONS Approved as submitted.Adhere to the installation of model#RG240T6N E.F. - .62. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 4/20/2017 Plumbing Permit Base Fee $25.00 4/20/2017 Processing/Technology Fee $25.00 4/20/2017 Water Heater $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON, WASHINGTON --- BUILDING DEPARTMENT _ No building construction shall be commenced until permit holder INSPECTION RECORD SHALL _ or hi�_aent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: WkezCONTRACTOR: rm JOB ADDRESS: w4sm (MIXD91k AF, OWNER ADDRESS: Z Wal USE of BUILDING: SFR PLAT NAME: Description of Work: } x LOT# PERMIT No: 14ya, Sprinklered: 1110 CONDITIONS_ f!- W, DATE ISSUED: Q 20.jX01"1 TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION 360403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) GAS PIPING(groundwork) ! ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION %VAILBOARD(SHEAR/RATING) ROOF DRAINAGE The following documents will be required and must be available during the final inspection: Completed Public Works & Utility Inspection Card Final electrical-sign off by L & I Completed Blower Door test certificate Completed Duct test certificate (if applicable) Conditions (if applicable) *indicates that the inspection Is approved but there is a minor correction FINAL INSPECTION Required Documents: CORRECTIONS ") CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 _ PHONE; (360)403-3551 BUILDING PERMIT Address:20429 81st Drive NE Permit#:1433 Parcel#:00825100001200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:HANSON AUDREY KATHLEEN Name:CM Heating Name:CM Heating Inc Address:20429 81ST DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-5969 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:CM Heating Inc Address: Address: 1415 Broadway City,State,Zip: City,State,Zip:Everett,WA 98201 Phone: Phone:425-259-0550 LIC#: EXP: LIC#:CMHEAM 1877DN EXP:03/15/2019 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington A tied on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date L"/"IWWBY Date CONDITIONS Approved as submitted. Adhere to the installation of model#RG240T6N E.F. - .62. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/20/2017 Plumbing Permit Base Fee $25.00 4/20/2017 Processing/Technology Fee $25.00 4/20/2017 Water Heater $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON, WASHINGTON --- BUILDING DEPARTMENT No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: w 11 CONTRACTOR: JOB ADDRESS: Uqm (blIx OWNER ADDRESS: 2RA2,11 sT USE of BUILDING: SFR PLAT NAME: Description of Work: LOT# PERMIT No: Sprinklered: 1�10 CONDITIONS: DATE ISSUED: .W.Z,01'1 TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION 360-403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION V ROOF DRAINAGE The following documents will be required and must be available during the final inspection: Completed Public Works & Utility Inspection Card Final electrical sign off by L & I Completed Blower Door test certificate Completed Duct test certificate (if applicable) Conditions (if applicable) *indicates that the inspection is approved but there is a minor correction FINAL INSPECTION Required Documents: CORRECTIONS (*) hR BRADFORD WHITE° W A T E R H E A T E R S Residential Atmospheric Vent Gas Water Heater The Atmospheric Vent FVIR Defender Safety System®Models Feature: Pj ■ Bradford White ICON System""*—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter.A standard,off the shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity. - Enhanced Performance—Proprietary algorithms provide enhanced First POP Hour Delivery ratings and tighter temperature differentials. -Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels. -Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting. -Pilot On Indication—Flashing green LED provides positive indication that pilot is on. -Separate Immersed Thermowell—High-strength advanced polymer composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve. ■ Advanced ScreenLok®Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. ■ Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow. ■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions. ■ Sight Window—Offers a view into the combustion chamber to observe the i operation of the pilot and burner. ■ Factory-Installed Hydrojet®Total Performance System—Sediment reducing a I device that also increases first hour delivery of hot water while minimizing temperature build-up in tank. ■ Vitraglas® Lining—An exclusively engineered enamel formula that provides _ superior tank protection from the highly corrosive effects of hot water.This formula(Vitraglas°)is fused to the steel surface by firing at a temperature of over j 1600-F(871°C). —� ■ Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss.This results in less energy consumption, improved efficiencies, and jacket rigidity. Photo is of ■ Pedestal Base. RG240T6N ■ Water Connections-3/4" NPT factory installed true dielectric fittings. ■ Factory-Installed Heat Traps. FEATURING: ■ Protective Magnesium Anode Rod. ■ 3x4"Snap Lock" Draft Diverter—Allows either 3" or 4" vent connections with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4" "Snap Lock" CON /� Draft Diverter. EsystemUP) ■ T&P Relief Valve—Installed. LL r L 1�BL It ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. ■ NOx Emissions-Less than 40 ng/J. *May vary by region 6 or 10-Year Limited Tank Warranties/6 or 10-Year Limited Warranty on Component Parts, CIP For more information on warranty, please visit www.bradfordwhite.com SA sA For products installed in USA,Canada and Puerto Rico.Some states do not allow limitations on warranties.See complete ® ,A copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S.PATENTS:5,682,666;7,634,976;5,660,165;5,954,492;6,056,542;6,935,280;5,372,185;5,485,879;5,574,822;7,971,560;7,992,526; 6,684,821;6,442,178;7,334,419;7,866,168;7,270,087;7,007,748;5,596,952;6,142,216;7,699,026;5,341,770;7,337,517;7,665,211;7,665,210;7,063,132;7,063,133;7,559,293;7,900,589;5,943,984; 8,082,888;5,988,117;7,621,238;7,650,859;5,761,379;7,409,925;5,277,171;8,146,772;7,458,341;2,262,174.OTHER U.S.AND FOREIGN PATENT APPLICATIONS PENDING.CURRENT CANADIAN PATENTS: 2,314,845;2,504,824;2,108,186;2,143,031;2,409,271,2,548,958,2,112,515,2,476,685,2,239,007,2,092,105,2,107,012.Defender Safety System',ScreenLok®,Vitraglas®and Hydrojet®are registered trademarks of Bradford White®Corporation. 1101-B-0417 Residential Atmospheric Vent Gas Water Heater Atmospheric Vent Models Meet or exceed ASHRAE 90.1b(current standard)C.E.C.Listed NATURAL GAS AND LIQUID PROPANE GAS Recovery efficiency ranging up to 80 Capacity Recovery A B C D E F G H Approx. Model 90°F Rise* Floor Jacket Vent Floor Floor Floor Floor Depth Shipping Number to Dia. Size to to to to Weight Nat. LP 1st Hour Nat. Nat. LP LP Flue T&P Gas Water Top of U.S. Impp. BTU/Hr. BTU/Hr. Rating Energy U.S. Imp. U.S. Imp. Conn. Conn. Conn. Conn. Heater Gal. GN. Input Input (Gal.) Factor GPH GPH GPH GPH in. in. in. in. in. in. in. in. lbs. RG130T6N• 30 25 27,000 27,000 52 0.63 29 24 29 24 5915h6 16 3X4 493/4/563/8 1211h6 571he 563/8 191/2 109 RG230T6N* 30 25 1 32,000 31,000 58 0.64 34 28 33 23 5915h6 1 18 3X4 497/8/563/8 1 1211/16 571/16 1 563/8 211/2 116 RG230S6N 30 25 30,000 32,000 56 0.63 32 37 32 27 491/4 20 3X4 385/8 1211/16 461/2 4511A6 231/2 113 RG140T6N• 40 33 34,000 34,000 70 0.62 37 31 37 31 611h 18 3X4 511/2/60 1211/16 591/4 5715/16 211/2 132 RG240T6N0 40 33 40,000 36,000 76 0.62 43 36 34 33 605h6 20 3X4 501/8/565/8 1211/16 579h6 563/4 231/2 134 RG240S6N0 40 33 40,000 35,000 74 0.62 43 36 41 34 513/4 22 3X4 41/471/4 1211h6 493h6 483/16 251/2 139 RG150T6N9 50 42 34,000 34,000 82 0.60 37 31 37 31 605h6 20 3X4 50/563/s 1211h6 575/8 563/4 231/2 150 RG250T6N9 50 42 40,000 35,000 89 0.62 43 36 41 34 605/16 22 3X4 497/8/57 1211/16 577/8 563/4 251/2 154 RG250L6N 48 40 40,000 35,000 88 0.60 43 36 41 34 5113/16 24 3X4 405/8 1211/16 493/8 483/16 271/2 170 RG250S6N6 50 42 50,000 48,000 1 93 0.60 1 54 45 52 45 1 605/s 22 4 497/s/57 1211/16 575/e 1 563/4 1 251/2 167 Capacity Recovery A B C D E F G H Approx. Model 50°C Rise* Floor Jacket Vent Floor Floor Floor Floor Depth Shipping Number to Dia. Size to to to to Weight Nat. LP 1st Hour Nat. LP Flue T&P Gas Water Top of kW kW Rating Energy Liters/ Liters/ Conn. Conn. Conn. Conn. Heater Liters Input Input (Liters) Factor Hour Hour mm. mm. mm. mm. mm. mm. mm. mm. kg. RG130T6N• 114 7.9 7.9 197 0.63 110 110 1522 406 76x102 1264/1432 322 1449 1432 495 49 RG230T6N6 114 1 9.4 9.1 220 0.64 129 125 1522 457 76x102 1267/1432 322 1449 1432 546 53 RG230S6N 114 8.8 9.4 212 0.63 121 121 1251 508 76x102 982 322 1181 1 1160 597 51 RG140T6N4 151 10.0 9.9 265 0.62 139 139 1562 457 76x102 1308/1524 322 1505 1472 546 60 RG240T6N• 151 11.7 10.6 288 0.62 163 129 1532 508 76x102 1273/1438 322 1462 1441 597 61 RG240S6N• 151 11.7 10.3 280 0.62 163 155 1314 559 76x102 1041/1200 322 1249 1224 648 63 RG150T6N• 189 10.0 9.9 310 0.60 139 139 1532 508 76x102 1270/1432 322 1464 1441 597 68 RG250T6N• 189 11.7 10.3 337 0.62 163 155 1532 559 76x102 1267/1448 1 322 1470 1441 648 77 RG250L6N 182 11.7 10.3 333 0.60 163 155 1316 610 76x1O21 1032 322 1254 1224 699 70 RG250S6N• 189 14.7 14.1 352 0.60 204 197 1540 559 102 1267/1448 322 1464 1441 648 76 Propane models feature a Titanium Stainless Steel propane burner.For Propane(LP) models change suffix"N"to"X". For 10 year models,change suffix from"6"to"l0". C *Based on manufacturer's rated recovery efficiency. *Models feature optional top T&P location and must be specified when ordering. Note:RG230S6N and RG25OL6N do not have top T&P option. Energy Factor and First Hour Rating is based on the latest AHRI directory listings. General: Meets NAECA Requirements. optional Top T&P valve All gas water heaters are certified at 300 PSI test pressure (2068 kPa)and 150 PSI working pressure g (1034 kPa).All water connections are a/"NPT(19mm)on 8" A (203mm)centers.All gas connections are'A"(13mm). 0 F G p All models design-certified by CSA International(formerly H o � o F AGA/CGA),ANSI standard Z-21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water(Potable)Heating and Space Heating. B E o Toxic chemicals,such as those used for boiler treatment, o shall NEVER be introduced into this system.This unit may NEVER be connected to any existing heating system or component(s)previously used with a non-potable water heating appliance. BRADFORD WHITE® W A T E R H E A T E R S Ambler,PA For U.S.and Canada field service,contact your professional installer or local Bradford White sales representative. Sales 800-523-2931•Fax 215-641-1670/Technical Support 800-334-3393•Fax 269-795-1089•Warranty 800-531-2111•Fax 269-795-1089 International:Telephone 215-641-9400•Telefax 215-641-9750/www.bradfordwhite.com BRADFORD WHITE-CANADWINC. Sales/Technical Support 866-690-0961/905-238-0100•Fax 905-238-0105/www.bradfordwhite.com Built to be the BeStTM ©2017,Bradford White Corporation.All rights reserved. 1101-B-0417 Printed in U.S.A. CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON,WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:20429 81st Drive NE Permit#:1433 Parcel 0:00925100001200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:HANSON AUDREY KATHLEEN Name:CM Heating Name:CM Healing Inc Address:20429 81ST DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-5969 City,State Zip:Everett,WA 98201 City,Slate Zip:Everett,WA 98201 Phone: Phone:425-259.0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:CM Heating Inc Address: Address: 1415 Broadway City,State,Zip: City,State,Zip:Everett,WA 98201 Phone: Phone:425-259-0550 LIC M EXP: LIC N:CMHEAMH877DN EXP:03/15/2019 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THL WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. :+ALES TAX NO'I'1 'F a Sales lax rclatin to construction and construction materials in the City of Arlington i to rled on your sales tax return form and 1 City of Arlingt n N 1 IAA t121 �� •I � Signature Print Name Date I I3y Date CONDITIONS Approved as submitted.Adhere to the installation of model#RG240T6N E.F. -.62. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 4/20/2017 Plumbing Permit Base Fee $25.00 4/20/2017 Processingfrechnology Fee $25.00 4/2O/2017 Water Heater $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for ao inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I " CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 ` PHONE; (360)403-3551 BUILDING PERMIT Address:20429 81st Drive NE Permit#:1433 Parcel#:00825100001200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:HANSON AUDREY KATHLEEN Name:CM Heating Name:CM Heating Inc Address:20429 81 ST DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-5969 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:CM Heating Inc Address: Address: 1415 Broadway City,State,Zip: City,State,Zip:Everett,WA 98201 Phone: Phone:425-259-0550 LIC#: EXP: LIC#:CMHEAMH877DN EXP:03/15/2019 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: ] OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington re orted on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date W A4lWWBy Date CONDITIONS Approved as submitted. Adhere to the installation of model#RG240T6N E.F. - .62. THIS PERMIT AUT 40RIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 4/20/2017 Plumbing Permit Base Fee $25.00 4/20/2017 Processing/Technology Fee $25.00 4/20/2017 Water Heater $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 4/20/2017 Permit Number 1433 Project Name Shreeve Applicant Name CM Heating Applicant Address 1415 Broadway City,State,Zip Everett,WA 98201 Contact Meredith Gilbert Phone 425-259-0550 Email meredith@cmheating.com Permit Type Residential Plumbing Site Address 20429 81 st Drive NE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use]Install HWT in garage Assigned To Kristin Foster Property Information Owner Information Parcel*00825100001200 HANSON AUDREY KATHLEEN HANSON AUDREY KATHLEEN 20429 81ST DR NE 20429 81 ST DR NE ARLINGTON,WA 98223-5969 Contractors Contractor Primary Phone Email Contractor Type License License# Name Contact (Meredith 425-259- (MECHANICAL Labor& CM Heating Inc ,Gilbert 0550 ieredith@cmheating.com"ONTRACTOR Industries CMHEAMH877DN Fees Fee Description Notes Amount Plumbing Permit Base Fee 322.10.00.00 $25.00 Processin frechnolo Fee 341.43.00.02 $25.0 Water Heatei 322.10.00.00 $25.00 Total $75.0 Payments Date I Paid By Amount I Description I Payment Type Accepted By 4/20/2017 EBORAH BAUERS $75.02P4355216 KC I Total $75.00 Amount Outstanding:$0.0 Notes Date Note 4/2 012 0 1 7 Model#RG240T6N E.F.-.62 Uploaded Files Upload File Date File Uploaded B 4/20/2017 10:24:52 AM 1433 A lication, df Foster, Kristin x 4/20/2017 10:24:52 AM 1433 Specs.pdf Foster, Kristin x U'7� � Y �fRESIDENTIAL PLUMBINO PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:20429 81st Drive Northeast Project Description:INSTALL 40 GALLON HWT IN GARAGE Owner: MICHAEL SHREEVE Address:20429 81st Drive Northeast City:ARLINGTON State:WA Zip Code: 98223 Phone: (206) 484-5956 Email: m_shreeve@yahoo.com Applicant:CM HEATING Address:1415 BROADWAY City:EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: MEREDITH@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address:1415 BROADWAY City�VERETT StateYVA Zip Code:98201 License Number:CMHEAMH877DN Expi ratio n:5/3/1 7 Phone:4252590550 Email:MEREDITH@CMHEATING.COM STAFF USE O Received Permit#: f"T�J Accepted by Date APR 1J 2017 REV 2015 Page 1 of 2 Y �f RESIncNT1nit DI I !MQmew dGa% rrr..r r ra~r.. ■ `v r■�r ■�v PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223• Phone(360) 403-3551 Plumbing Section (check all that apply) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x ❑ Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1.0) x Clothes Washer (4.0) x Water Closet (2.5) x ❑ Dishwasher (1.5) x Water Heater x 1 Hose Bibb (2.5) x Water Heater Model# Other (list) x RG240T6N Proposed Water Piping Size:3/4" Proposed Piping Material: COPPER Proposed DWV Material:B VENT Proposed DWV Size: 3° • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASS 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Applicant Signature: 's Date: 04/19/2017 I hereby certify that the above information is correct and that the construction, installation for the-abdug mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. REV 2015 Page 2 of 2 bft BRADFORD WHITE W A T E R H E A T E R S Residential Atmospheric Vent Gas Water Heater _AAk The Atmospheric Vent FVIR Defender Safety System®Models Feature: it ea>_a ■ Bradford White ICON System"'*—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter.A standard,off the shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor.No need for external electricity. —Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery ratings and tighter temperature differentials. —Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels. —Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting. —Pilot On Indication—Flashing green LED provides positive indication that pilot is on. —Separate Immersed Thermowell—High-strength advanced polymer composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve. ■ Advanced ScreenLok®Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. ■ Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow. ■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions. ■ Sight Window—Offers a view into the combustion chamber to observe the 4 operation of the pilot and burner. 11-0 ■ Factory-Installed Hydrojer Total Performance System—Sediment reducing device that also increases first hour delivery of hot water while minimizing temperature build-up in tank. ■ Vitraglase Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water.This formula(Vitraglas®)is fused to the steel surface by firing at a temperature of over r.• ■ Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss.This results in less energy consumption, improved efficiencies,and jacket rigidity. Photo is of ■ Pedestal Base. RG240T6N ■ Water Connections-3,4" NFT factory installed true dielectric fittings. ■ Factory-Installed Heat Traps. FEATURING: ■ Protective Magnesium Anode Rod. • _ ■ 3x4"Snap Lock" Draft Diverter—Allows either 3" or 4"vent connections with inputs of 40,000 BTU/Hr.or less. Over 40,000 BTU/Hr.has the 4" "Snap Lock" CON 1 Draft Diverter. System ( ■ T&P Relief Valve—Installed. ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. �- ■ NOx Emissions—Less than 40 ng/J. 'May vary by region e 6 or 10-Year Limited Tank Warranties/6 or 10-Year Limited Warranty on Component Parts. For more information on warranty,please visit o.Somea states d not allow For products installed in USA,Canada and Puerto Rico.Some states do not allow limitations on warranties.See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S.PATENTS:5,682,666;7.634,976;5,660.165;5,954,492;6.056,542;6,935,280;5,372.185;5.485,879;5.574,822;7.971,560;7,992,526; 6,694.021:6.442,178;7,334,419;7.866.168;7,270,087;7,007,748;5.596,952;6,142,216;7.699,026;5,341,770;7.337,517;7.665.211;7.665,210:7,063,132:7,063,133;7.559.293:7.900,509;5,943,984; 8,082,888;5,9B8,117;7,621,238;7,650,859;5,761,379;7,409.925;5,277,171;8,146,772;7,458,341;2,262,174.OTHER U.S.AND FOREIGN PATENT APPLICATIONS PENDING.CURRENT CANADIAN PATENTS: 2,314,845;2,504.824;2,1Oa,186;2,143,031;2,409,271;2,548,958;2,112,515;2,476.685;2,239.007;2,092,105;2,107,012.Defender Safety System*,ScreenLok-,Vllraplas-and Hydrolet-are registered trademarks of Bradford White'Corporation. 1101-B-0417 Residential Atmospheric Vent Gas Water Heater Atmospheric Vent Models Meet or exceed ASHRAE 90.1b(current standard)C.E.C.Listed NATURAL GAS AND LIQUID PROPANE GAS Recovery efficiency ranging up to 80 Capacity Recovery A B C D E F G H Approx. Model 901 Rise` Floor Jacket Vent Floor Floor Floor Floor Depth Shipping Number to Dia. Size to to to to We ght Nat. LP Is[Hour Nat. Nat. LP LP Flue T&P Gas Water Top of U.S. Imp. 1TU0. BTUA4 Ratan Energy U.S. Impp. U.S. Imp. Conn. Conn. Conn. Conn. Heater Gal. Gal. Input Input Gal. Factor GPH GPH GPH GPH in. in. in. in. In. in. in. in. Us. RG130T6N• 30 25 27.000 27,000 52 0.63 29 24 29 24 5915/16 16 3X4 493/4/563/9 1211/16 571/16 561/9 191/2 109 RG230T6N• 30 25 32.000 31,000 58 0.64 34 28 33 23 5915/16 18 3X4 497/9/563/9 1211/16 571/16 563/9 211h 116 RG230S6N M 25 30.000 32,000 56 0.63 32 37 32 27 49114 20 3X4 386/9 1211/76 461/2 4511/16 231/2 113 RG140T6N• 40 33 34,000 34,000 70 0.62 37 31 37 31 611h 16 3X4 511/2/60 1211/m 591/4 5711/16 211h 132 RG240T6N6 40 33 40,000 36,000 76 0.62 43 36 34 33 605/16 20 3X4 501/9/565/e 1211/16 571/16 563/4 231h 134 RG240S6N• 40 33 40.000 35,000 74 0.62 43 36 41 34 51a/4 22 3X4 41/471/4 1211/1s 493/1s 481/1s 251h 139 RG150T6N6 50 42 34,000 34,000 82 0.60 37 31 37 31 605/16 20 3X4 50/563/9 1211/1s 575/e 1 56314 231h 150 RG250T6N• 50 42 40,000 35.000 89 0.62 43 36 41 34 605/16 22 3X4 497/9/57 1211he 57716 563/4 251/2 154 RG250L6N 48 40 40,000 35,000 1 88 0,60 43 36 41 34 5113he 24 3X4 401/9 1211hs 493/9 483/1e 271/2 1 170 RG250S6N• 50 42 50.000 48.000 1 93 0.60 54 45 52 45 1 605/e 1 22 1 4 497/9/57 1211/16 575/9 563/4 251/2 1 167 Capacity Recovery A B C D E F G If Approx. Model 50°C Rise* Floor Jacket Vent Floor Floor Floor Floor Depth Shipping Number to Dia. Size to to to to We ghl Nat. LP 1st Hour Nat. LP Flue T&P Gas Water Top of kW kW Rating Energy Liters/ Liters/ Conn. Conn. Conn. Conn. Healer Liters Input Input Liters Factor Hour Hour mm. mm. mm. mm. mm. mm. mm. mm. kg. RG130T6N6 114 7.9 7.9 197 0.63 110 110 1522 406 76x102 1264/1432 322 1449 1432 495 49 RG230T6N• 114 9.4 9.1 220 0.64 129 125 1522 457 76002 1267/1432 322 1449 1432 546 53 RG230S6N 114 0.8 9.4 212 0.63 121 121 1251 500 76x102 982 322 1181 1160 597 51 RG140T6N• 151 10.0 9.9 265 0.62 139 139 1562 457 76x102 1308/1524 322 1505 1472 546 60 RG240T6N• 151 11.7 10.6 288 0.62 163 129 1532 508 76x102 1273/1438 322 1462 1441 597 61 RG240S6N0 151 11.7 10.3 280 0.62 163 155 1314 559 76x102 1041/1200 322 1249 1224 648 63 RG150T6N• 189 10.0 9.9 310 0.60 139 139 1532 508 76002 1270/1432 322 1464 1441 597 68 RG250T6N8 1 189 11.7 10.3 337 0.62 163 155 1532 559 76x102 1267/1448 322 1470 1441 648 77 RG250L6N 182 11.7 10.3 333 0.60 163 155 1316 610 76x102 1032 322 1254 1224 699 70 RG250S6N0 189 14.7 14.1 352 0.60 1 204 197 1 1540 1 559 1 102 11267/1448 1 322 1464 1 1441 1 648 76 Propane models feature a Titanium Stainless Steel propane burner.For Propane(LP) models change suffix"N"to"X". For 10 year models,change suffix from"6"to"l0". C "Based on manufacturer's rated recovery efficiency. •Models feature optional top T&P location and must be specified when ordering. Note:RG230S6N and RG2501_6N do not have top T&P option. Energy Factor and First Hour Rating is based on the latest AHRI directory listings. General: Meets NAECA Requirements. optional Top T&P vane All gas water heaters are certified at 300 PSI test pressure (2068 kPa)and 150 PSI working pressure 8n_ (1034 kPa).All water connections are 114"NPT(19mm)on 8' A (203mm)centers.All gas connections are f"(13mm). ® O I F G D All models design-certified by CSA International(formerly F _ _ AGA/CGA),ANSI standard Z-21.10.1 and peak performance H rated. 0- Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. L T Suitable for Water(Potable)Heating and Space Heating. B E Toxic chemicals,such as those used for boiler treatment, o shall NEVER be introduced into this system.This unit may NEVER be connected to any existing heating system or component(s)previously used with a non-potable water heating appliance. 1110 BR.4DF'ORD WHITE' lV A T F" H f I T I N P, Ambler,PA For U.S.and Canada field service,contact your professional installer or local Bradford White sales representative. Sales 800-523-2931•Fax 215-641-1670/Technical Support 800-334-3393 a Fax 269-795-1069•Warranty 800-MI-2111•Fax 269-795.1089 C� International:Telephone 215-641-9400•Telefax 215-641-9750/www.bradfordwhite.com BRADFORD WPUTE-CANADW INC. Sales/Technical Support 866-690-0961/905-238-0100•Fax 90&2,1&0105/www.bradfor&hite.com Built to be the Best TM ©2017,Bradford White Corporation.All rights reserved. 1101-B-0417 Printed in U.S.A. Kristin Foster From: Meredith CM <meredith@cmheating.com> Sent: Thursday,April 20, 2017 10:39 AM To: Kristin Foster Subject: Re: City Of Arlington Transaction Confirmation,KID: 64355216 Like for like in the garage. Meredith Gilbert 425-259-0550 On Thu, Apr 20, 2017 at 10:32 AM, Kristin Foster<kfoster_,arlin tog nwa.gov> wrote: Is this a like-for-like change out with the existing HWT located in the garage, or are you relocating the tank to the garage from another area of the home?Thanks Kristin Foster Permit Technician City of Arlington 18204 591h Ave NE Arlington, WA 98223 360 403 3549 kfoster@arlinetonwa.eov FINALIST The Arlington/Darrington community has been selected as a finalist in the nationwide America's Best Communities competition. Read more here,and like our ABC Facebook page 1 From: Meredith CM [mailto:meredith@cmheating.com] Sent:Thursday,April 20,201710:32 AM To: Kristin Foster<kfoster@arlinetonwa.gov> Subject: Fwd: City Of Arlington Transaction Confirmation,XID:64355216 Paid! Meredith Gilbert 425-259-0550 ---------- Forwarded message ---------- From: City Of Arlington Transaction Processing<norepl Aitransact.com> Date: Thu, Apr 20, 2017 at 10:30 AM Subject: City Of Arlington Transaction Confirmation, XID: 64355216 To: DEBORAH BAUERS<meredith@cmheating.com> DEBORAH BAUERS, Thank you! The following transaction was processed. This email will serve as your receipt. For questions, please contact ced@arlingtonwa.gov. TRANSACTION DETAIL ----------------------------------------------- Merchant Name: City Of Arlington URL: http://www.arlingtonwa.gov/ Last Four Digits: 2497 Card Type: Visa Authorized Amount: 75.00 Date & Time: 4/20/2017 11:30:28 Transaction ID: 64355216 IP Address: Logged for security purposes. 2 YOUR INFORMATION: ----------------------------------------------- Customer Name: DEBORAH BAUERS Address: 1415 BROADWAY City, St. ZIP: EVERETT, WA 98201 Country: United States Telephone: 4252590550 E-Mail Address: meredith_,cmheating.com Customer ID: Description Amount Quantity Item Total ------------------------------------------ ------ -------- ---------- Plumbing Permit Base Fee 25.00 1 25.00 Processing/Technology Fee 25.00 1 25.00 Water Heater 25.00 1 25.00 ------------------------------------------------------------------------ Order Total 75.00 Sincerely, City Of Arlington 3 i i 4/20/2017 C M HEATING INC 1 Search L&I 1-f ln,lr.y [k'lp [} 1&-1 Safety&1 le'llth Claim- &. insurance Workplace Rights Trades & Licensing 410*4 Washington State Department of kj Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY Principals EVERETT,WA 98201 425-259-6666 Gam SNOHOMIS Garner,James N,PRESIDENT NOHH County Umayam,John A,VICE PRESIDENT Umayam,Antonio(Tony)G,SECRETARY Umayam,Antonio(Tony)G,TREASURER Gamer,James N,AGENT Gamer, Paul,PRESIDENT (End:06129/2016) Gamer, Kathleen D,SECRETARY (End:06/29/2016) Gamer,Kathleen D,TREASURER (End:06/29/2016) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. CMHEAMH877DN Effective—expiration 03/15/2013—03/15/2019 Designated administrator Active. Giacomi,John Meets current requirements. License type License no. Electrical Administrator GIACOJ'840MG Bond Contractors Bonding&Insurance Co $4,000.00 Bond account no. SC6810 Received by L&I Effective date Help us improve https://secure.i ni.wa.gov/verify/Detail.aspx?UBI=601114652&LIC=CMHEAMH877DN&SAW= 112 4/20/2017 C M HEATING INC 03/15/2013 02/28/2000 Expiration date Until Canceled Savings ...................... No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 4 of Year 2016"31 to 50 Workers" L&I account representative T4/JULIE SUR(360)9024825-Email:SURJ235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 0 311 6/201 5 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 Inspection results date 08/01/2011 Violations Inspection no. 315054981 Location 912 Rucker Everett,WA 98201 J Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. Ua iYE'prtovt' hops://secure.Ini.wa.gov/verify/Detail.aspx?U BI=601114652&LIC=CM H EAM H877D N&SAW= 2/2 BUILDING INSPECTION REPORT — PLUMBING (HWT) Permit No 1433 Address: 20429 81st Drive NE Contractor: CM Heating Owner: Shreeve Date: 5/10/2017 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: HWT LOCATION OK: N L&I: ❑ EXPANSION TANK: N SEISMIC: N INSULATION: N VENTING (6x6 collar): N 18 INCHES OR FVIR: N PRV 6 INCHES: ❑ SHUT-OFF VALVE: N PRV< 150PSI: N DRAIN: N DRIP LEG: N IMPACT PROTECTION: N ACCESS: N COMBUSTION AIR: N Date: 5/10/2017 Inspector: Kevin Olander Kristin Foster From: Meredith CM <meredith@cmheating.com> Sent: Thursday, April 20, 2017 10:39 AM To: Kristin Foster Subject: Re: City Of Arlington Transaction Confirmation, XID: 64355216 Like for like in the garage. Meredith Gilbert 425-259-0550 x On Thu, Apr 20, 2017 at 10:32 AM, Kristin Foster<kfosterkarlin tog nwa. og_v>wrote: Is this a like-for-like change out with the existing HWT located in the garage, or are you relocating the tank to the garage from another area of the home?Thanks Kristin Foster Permit Technician City of Arlington 18204 59th Ave NE Arlington, WA 98223 360 403 3549 kfoster@arlingtonwa.gov FINALIST The Arlington/Darrington community has been selected as a finalist in the nationwide America's Best Communities competition. Read more here,and like our ABC Facebook page 1 From: Meredith CM [mailto:meredith@cmheating.com] Sent:Thursday, April 20, 2017 10:32 AM To: Kristin Foster<kfoster@arlingtonwa.gov> Subject: Fwd: City Of Arlington Transaction Confirmation, XID: 64355216 Paid! Meredith Gilbert 425-259-0550 ---------- Forwarded message ---------- From: City Of Arlington Transaction Processing<noreplykitransact.com> Date: Thu, Apr 20, 2017 at 10:30 AM Subject: City Of Arlington Transaction Confirmation, XID: 64355216 To: DEBORAH BAUERS <meredith(abcmheating.com> DEBORAH BAUERS, Thank you! The following transaction was processed. This email will serve as your receipt. For questions, please contact ced&arlingtonwa.gov. TRANSACTION DETAIL ----------------------------------------------- Merchant Name: City Of Arlington URL: htt2://www.arlingtonwa.gov/ Last Four Digits: 2497 Card Type: Visa Authorized Amount: 75.00 Date & Time: 4/20/2017 11:30:28 Transaction ID: 64355216 IP Address: Logged for security purposes. 2 i YOUR INFORMATION: ----------------------------------------------- Customer Name: DEBORAH BAUERS Address: 1415 BROADWAY City, St. ZIP: EVERETT, WA 98201 Country: United States Telephone: 4252590550 E-Mail Address: meredith(ccmheating com Customer ID: Description Amount Quantity Item Total Plumbing Permit Base Fee 25.00 1 25.00 Processing/Technology Fee 25.00 1 25.00 Water Heater 25.00 1 25.00 ------------------------------------------------------------------------ Order Total 75.00 Sincerely, City Of Arlington 3 Permit#: 1433 Permit Date: 04/20/17 Permit Type: RESIDENTIAL PLUMBING Project Name Shreeve Applicant Nam a CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA98201 Contact: Meredith Gilbert Phone: 425-259-0550 Em al: m credith@cm Irating.com Scope of Work: Install HWT in garage Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 04/20/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wner Nam e Caner Phone Zoning 00825100001200 2 0429 81 ST DR NE HANSON AUDREY 111 Single Fam iy KATHLEEN Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION Plum fing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION UBI 6 05890285 ST STE 200 CONTRACTOR Fees Fee D escription N otes A m atnt Plum hng Base P erm i Fee $ 25.00 Processing/Technology $25.00 Wier Heater(Tank) $25.00 Total $75.00 Attached Letters Date Letter D escription 04/20/2017 Building Perm i Paym acts Date Paid By D escription P aym ant Type A ccepted By A m mnt 04/20/2017 DEBORAH BAUERS 6 4355216 c c $75.00 O ttstanding Balance $0.00 Notes Date Note C reated By: 04/20/2017 Model#RG240T6N E.F.-.62 K ristin Foster Uploaded Files Date File Nam e 05/10/2017 2277719-20429 81st Drive NE.docx 04/21/2017 2235139-1433 Issued Perm i.pdf 04/20/2017 2231429-CM Heating Em al.pdf 04/20/2017 2231204-1433 Specs.pdf 04/20/2017 2231205-1433 Application.pdf Permit#: 1433 Permit Date: 04/20/17 Permit Type: RESIDENTIAL PLUMBING Project Name Shreeve Applicant Nam a CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA98201 Contact: Meredith Gilbert Phone: 425-259-0550 Em al: m credith@cm Irating.com Scope of Work: Install HWT in garage Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 04/20/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wner Nam e Caner Phone Zoning 00825100001200 2 0429 81 ST DR NE HANSON AUDREY 111 Single Fam iy KATHLEEN Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION Plum fing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION UBI 6 05890285 ST STE 200 CONTRACTOR Fees Fee D escription N otes A m atnt Plum hng Base P erm i Fee $ 25.00 Processing/Technology $25.00 Wier Heater(Tank) $25.00 Total $75.00 Attached Letters Date Letter D escription 04/20/2017 Building Perm i Paym acts Date Paid By D escription P aym ant Type A ccepted By A m mnt 04/20/2017 DEBORAH BAUERS 6 4355216 c c $75.00 O ttstanding Balance $0.00 Notes Date Note C reated By: 04/20/2017 Model#RG240T6N E.F.-.62 K ristin Foster Uploaded Files Date File Nam e 05/10/2017 2277719-20429 81st Drive NE.docx 04/21/2017 2235139-1433 Issued Perm i.pdf 04/20/2017 2231429-CM Heating Em al.pdf 04/20/2017 2231204-1433 Specs.pdf 04/20/2017 2231205-1433 Application.pdf