BUILDING PERMIT
Address:6010 199th St Permit 4:236
Parcel ii:00746300000800 Valuation:
OWNER APPLICANT CONTRACTOR
Namc:AMANGTON LAND 14OLDINGS LLC Name:Vinnie&Sons Plumbing Name:Vinnie&Sons Plumbing
Address:PO BOX 1600 Address:105-B W.Main St Address: 105-B W.Main St
City,State Zip;ORTING,WA 98360 City,State Zip:Puyallup,WA 98371 City,State Zip:Puyallup,WA 98371
Phone: Phone:253-232-3298 Phone:253-232-3298
Nr ar~il.iZl11\It..
Name: Name:Vinnie&Sons Plumbing
Address: Address:105-B W.Main St
City,State,Zip: City,State,Zip:Puyallup,WA 98371
Phone: Plione:253-232-3298
LTC#: EXP: LTC 4:VI14NISP961 ME EXP:8/13/2014
JOB DESCRIPTION
PI RMITTYPE: Commercial.Plumbing CODE YEAR: 2012
STORIES: CONST,TYPE:
DIA ELLING UNITS' OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGRI;G TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZ D
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF T11E STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 1&27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARR IIAI1).
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL TNSPECTTON I IAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I IO/IRC110,
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City,R rlin On must be reported on your sales tax return form
and cRdeti City of Arlington 113101. I�
Signature Print Name Date Rrmcd B3e Date
CONDITIONS-:
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURES,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL,REQUIRE SEPARATE PERMISSION,
PERMIT FEES
Date Doscription Fee Amount
11/14/2013 Plumbing Permit Fee(Enter Fixture Fee) $229.00
1 1/1 412 01 3 Plumbing Plan Review Fees $350.00
Total Due: $579.00
Total Payment: $579.00
Balance Due: $0.00
CALL FOR INSPECTIONS
a
BUILDING(36U)403-3417
When calling for an Inspection please leave the following information:
Permit Number,Type or Inspection being requested,and whether you prefer morning or afternoon
— I
CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
02 PHONE; (360) 403-3551
BUILDING PERMIT
Address:6010 199th St Permit#:236
Parcel#:00746300000800 Valuation:
OWNER APPLICANT CONTRACTOR
Name:ARLINGTON LAND HOLDINGS LLC Name:Vinnie&Sons Plumbing Name:Vinnie&Sons Plumbing
Address:PO BOX 1600 Address: 105-B W.Main St Address: 105-B W.Main St
City,State Zip:ORTING,WA 98360 City,State Zip:Puyallup,WA 98371 City,State Zip:Puyallup,WA 98371
Phone: Phone:253-232-3298 Phone:253-232-3298
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:Vinnie&Sons Plumbing
Address: Address: 105-B W.Main St
City,State,Zip: City,State,Zip:Puyallup,WA 98371
Phone: Phone:253-232-3298
LIC#: EXP: LIC#:VINNISP96IMH EXP: 8/13/2014
JOB DESCRIPTION
PERMIT TYPE: Commercial Plumbing CODE YEAR: 2012
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF T14E LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRCI10.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City o rlin ton must be reported on your sales tax return form
and coded City of Arlington#3101.
Signature Print Name Date Rc dscd B Date
CONDITIONS
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
11/14/2013 Plumbing Permit Fee(Enter Fixture Fee) $229.00
11/14/2013 Plumbing Plan Review Fees $350.00
Total Due: S579.00
Total Payment: $579.00
Balance Due: S0.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
' -
-
�
_ - _ - _ - _ _ _ - -_ _ - _ _ - - .
�
-� .� . .
/ �w - . . '.'
.^ " /
'
�
�
�
'
�
I
WATER SUPPLY AND DISTRIBUTION
TABLE 610.4
FIXTURE UNIT TABLE FOR DETERMINING WATER PIPE ND METER SIZES
METER AND BUILDING MAXIMUM ALLOWABLE LENGTH
STREET SUPPLY (feet)
SERVICE AND
(inches) I BRANCHES 40 + 60 I en Ila I 150 1 200 i
250 300 400 500 ! am I 700 I 000 i
800 1000
(inches)
PRESSURE RANGE—30 to 45 pslt
ff 1h2 6 5 4 3 2 1 1 1 0 0 1 0 0 0 0 0
1/4 % 16 16 14 12 9 6 5 5 4 4 3 2 2 2 _ 1
1/4 1 29 25 ; 23 21 17 15 13 12 I 10 8 6 6 6 _ 6 6 _
I 1 36 31 27 25 20 17 15 13 12 10 C 8 6 6 6 6
3A 1%4 36 33 31 28 24 I 23 21 19 17 16 13 12 12 11 11
1 1'/4 54 47 42 38 32 I` 28 25 23 19 17 14 i 12 12 II II
1'h 1'/A 78 68 57 48 38 32 28 25 21 18 15 12 12 11 11
1 1!6 85 84 79 65 56 I 48 43 38 32 28 26 22 21 20 20
1�$ 1'/2 150 124 105 91 70 57 49 45 36 31 26 23 21 20 20
2 1'h 151 129 129 110 80 64 53 46 38 32 27 23 21 20 i 20
1 2 85 85 85 85 85 85 82 80 66 61 57 52 49 46 43
2 220 205 190 176 155 138 127 _120 104 85 70 61 57 54 51
` 2 2 370 327 292 265 217 185 164 147 124 + 96 70 61 57 54 51
2 2'/z 445 418 390 370 330 300 280 265 24.0 1220 198 175 158 1;13 133
PRESSURE RANGE—46 to 60 pslt
r/4 �/2 ! 7 7 I 6 i 5 4 3 2 2 I 1 1 1 0 0 0 0
1/4 '/4 20 1 20 +i 19 17 14 11 9 1 8 6 5 4 4 3 3 3
%4 1 39 39 36 33 28 23 21 19 17 14 12 10 9 8 8
I 1 39 39 39 36 30 25 23 i 20 18 15 12 10 9 8 8
3/4 1%4 39 39 39 39 39 39 34 i 32 27 25 22 19 19 17 16
1 1%4 78 I 78 76 67 52 44 39 36 30 27 24 20 19 17 16
11h 1'/4 78 I 78 78 78 66 52 44 39 33 1 29 24 20 19 17 16
1%z ( 85 85 85 85 85 ? 85 80 67 55 49 41 37 34 32 30
l% 1%2 151 151 151 151 128 105 90 78 62 52 42 38 35 32 30
2 1%2 151 151 151 151 150 117 98 84 67 55 42 38 35 32 30
1 2 85 85 85 85 85 85 85 85 85 85 85 85 85 83 80
I�i 2 370 370 340 1319 1272 240 220 198 170 150 135 123 110 102 94
2 2 370 370 370 370 f 368 318 280 250 205 165 142 123 110 102 94
2 2%2 654 640 610 >80 535 500 470 440 400 365 335 . 315 285 267 250
PRESSURE RANGE—Over 60 psit
7 7 7 6 5 4 3 3 2 1 1 1 1 1 0
'/ '/ 20 20 20 20 17 13 11 10 8 7 6 6 5 4 4
'/4 1 39 39 39 39 35 30 27 24 21 17 14 13 12 12 11
1 1 39 39 39 39 38 32 29 26 22 18 14 13 12 12 11 1
3/4 1'/a 39 39 39 39 I 39 39 39 _39 34 28 26 25 23 22 21
1 1'/4 78 78 78 78 74 62 53 47 39 31 26 25 23 22 21
1'/2 1'A 78 78 78 78 78 74 65 54 43 34 26 25 23 22 21
I''/2 85 85 1 85 85 1 85 1 85 85 85 81 64 51 48 46 43 40
IIA : 151 151 � 151 151 151 151 130 113 88 73 51 51 46 43 40
2 11/2151 151 151 151 151 151 142 122 98 82 64 51 46 43 _ 40
i
1 2 85 85 85 85 85 85 85 85 85 85 85 85 85 1 85 f 85
1'/2 2 370 370 370 370 _ 360 jI 335 305 282 244 212 187 172 153 141 129
1
2 2 370 370 370 370 370 j 370 370 340 288 245 204 172 153 141 129
2 2% 654 654 654 654 654 650 1 610 570 510 460 1430 404 380 1356 329
For SI units: I inch=25 nun,1 foot=304.8 mm,l pound-force per square inch=6.8947 kpa
Notes:
1 Available static pressure after head loss.
2 Building supply,not less than 3/4 of an inch(20 mm)nominal size.
106 UNIFORM PLUMBING CODE
Christopher Young
From: James Kelly
Sent: Friday, August 02, 2013 3:42 PM
To: Christopher Young
Cc: Linda Taylor; Kris Wallace; Amy Rusko; Launa Peterson
Subject: RE: Scott Galvanizing Project
Chris—
Scott Galvanizing Connection Fee Estimate
Office—480 SF for Temp Office and 2400 SF for Permanent Office at
1 ERU Wat/Sew
Manufacturing—34,624 SF at for fabrication building at 0.1 ERU/ 1000 SF = 3 ERU,
however since this is a low water consumption building with less than 15
fixture count, a 1 ERU connection is the appropriate impact to the wat &sew
system. If fixture count is different than 15, connection fee may be reassessed.
1 ERU Wat/Sew
Billing Units—To be established when waste characterization is available
2 ERU Charge with 5/8" meter (ESTIMATE)
Water Connection $ 8,600
Sewer Connection $ 16,800
Meter Fee(5/8") $ 720
Sewer Inspection 360 Note 1
$ 26,480
Note 1-$180 per connection inspection
Thanks-Jim
From: James Kelly
Sent: Friday, August 02, 2013 2:48 PM
To: Christopher:Young; Linda Taylor
Subject: RE: Scott Galvanizing Project
Thank Chris—so for today, do you want a connection fee estimate for the office building or for both the office
and manufacturing building?
Jim
From: Christopher Young
Sent: Friday, August 02, 2013 11:30 AM
To: Linda Taylor
Cc: James Kelly
Subject: RE: Scott Galvanizing Project
That is typically determined at the time of plumbing submittal but based on the proposed plan their demand indicates
15 water service fixture units. A 5/8 inch meter can supply 39 units.
1
Christopher Young
Building Official
City of Arlington
360-403-3432
cyoung@arlingtonwa.gov
In Ja
"The importance of a strong building code is most evident after a disaster."
From: Linda Taylor
Sent: Friday, August 02, 2013 10:42 AM
To: Christopher Young
Cc: James Kelly
Subject: Scott Galvanizing Project
Jim has asked me to contact you for information regarding fixture count to determine what water meter size you
determined would be needed for this project.
Thank you
L bnzIa,1"wyl&r
Ad4,a,�GXt'we,spec,ia&St
P C41Ar 0 W crv'4 O ff f c&
iDe,s�P .ane; 360-403-3516
0ffu;e.,Ph& ie, 360-403-3526
ltcwlrn-@arliv�,�Fto-vuwa��oy
2
COMMERCIAL PLUMBING
PERMIT APPLICATION
Department of Community Development
City of Arlington • 238 N Olympic Ave. • Arlington, WA 98223 • Phone (360)403 3551 • FAX (360)403 3418
THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3) SETS OF CONSTRUCTION DRAWINGS, AND THREE
(.3) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE
INTERCEPTOR IF APPLICABLE.
Type of Permit: MCommercial ® Commercial Addition/Alteration ([]) Industrial
Project Address: (1901/0 9 9"'L 71:�+'Ah'05 Parcel ID M
Lot#: cc 1 Subdivision:
Project Description:Vic` �/ k I a t CA valuation:
Owner: &-GLkVC<J+i7-'4 Phone Number:
Address: < c)/C7 /�`1'�- SJ� •N k City:mil!n&�i State: 10 d Zip Code:
Contact Person: r�� l Z -P�Q S r�--" f"-I- Phone Number:
Cell Phone: 41, - 37 1S'$S E-mail: �`i C 2 �e"�'JC'C�b-IUG.
Address: r ,q-. 'd 1C0 City; State: 10-4 Zip Code:949a0
Please List quantity of fixtures Below: U
0 WATER CLOSET BATH TUB SHOWERS
_._., LAVATORIES CLOTHES WASHER LAUNDRY TUBS
_3 FLOOR DRAINS FLOOR SINKS —L_ SINKS
_3 URINALS SUMPS DISHWASHERS
i WATER HEATERS ROOF DRAINS WATER PIPING
DWV ALTER/REPAIR LAWN SPRINKLERS DRINKING FOUNTAINS
MISC PLUMB FIXTURE GREASE INTERCEPTOR GREASE TRAP
+ 2- $ , - 17 cubs Cy 1t e z a t tS : -ZZ- 4-
3) 3 Ss pPmv
Contractor_ )J` oe- L L C/ Phone Number.
Address: \�'�1/�?��_� City `� ��"`
7`K State: � Zip Code: 7�
Contractors License Number:1r,�-r�u-� ��� Mil Expiration: .
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be in accordance with the laws,rules and regulation of the State of Washington.
Applicants Signature LAte
�01 csrt-S SY� -�l x�✓
Print Applicants Name
IC
FOR STAFF USE ONLY
NOV 12 2013
Pnrmd# Accepted By Amount Received Receipt# COAPPERVITCENTEN
.ti-t
��. �-.
� - �
. �
'� - s
:AR
r
COMMERCIAL PLUMBING
PERMIT APPLICATION
Department of Community Development
City of Arlington• 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3561 • FAX(360)403 3418
CROSS-CONNECTION SURVEY FORM
(Please complete form and submit to Permit Center)
NOTE: The Rules and Regulations of the State of Washington Department of Health require that certain premises install
backflow prevention assemblies(WAC 246.290.490). Backflow prevention assemblies shall be installed at any premise
where, in the judgment of the City of Arlington Cross Connection Control Specialist, the nature of activities on the premise
may present a hazard to the public water system.
Type of Permit: $Commercial ® Commercial Addition/Alteration Industrial
Proposed Building Use: ® Restaurant it] Medical Industrial
0 Residential Commercial C)Other:
Contact Person. I 1 CJC'e--.5 S�'e L� Y Phone Number: 0�3" �3�
Cell Phone:PS3 Fax: �S3 ',�ylo-'7/.S3 E-mail: dd(R Y1nyZ•e Q."C1S0vX,S
Please check all appliances and/or applications that are permanently to the water supply
and apply to your proposed USE and OPERATION.
0 Ice Maker (0) Dialysis Equip. 0 Airwashers () Swimming Pools Fire Sprinkler
0 Espresso Mach. ® Hydrotherapy 0 Steam Generators 0 Hot Tub/Spa O Sprinkler w/chemicals
Equip.
0 Carbonated Bev. O Dental Equip. 0 Dye Vats 0 Ice Machine Lawn irrigation
O Fume Hoods ® Laboratory Equip. 0 Pressure Washers 0 Coffee Urn/Espress. Well on property
0 Degreasers 0 Autoclave/Sterilizers 0 Cooling Towers 0 Aquarium ® Decorative Fountain
LLD' Other:
Authorized Signature:�� 1 Date: 11 la
Office Use Only
Comments:
Date Received: Survey Received By:
Assembly Required: ❑ DCVA ❑ RPBA ❑ AVB ❑ Other
Inspection Required: ❑ YES ❑ NO
I
COMMERCIAL PLUMBING
PERMIT APPLICATION
Department of Community Development
City of Arlington• 238 N Olympic Ave. •Arlington,WA 98223 • Phone(360)403 3551 • FAX(360)403 3418
WASTEWATER DISCHARGE SURVEY FORM
(Please Complete form and submit to Permit Center)
NOTE. Arlington Municipal Code 13.06.590 requires that any and all commercial or industrial dischargers will not
discharge to the City of Arlington Sanitary Sewer System without a negotiated discharge agreement. This survey will help
us determine whether your business will require an agreement.
1, Type of Permit: �4—Cornmercial (❑) Industrial ® Commercial Addition/Alteration
2. Proposed Building Use: i) Restaurant Medical ® Industrial
Residential Commercial Q3 Automotive Based
0 Machine Shop ()Other: _
3. Does the plumbing system currently have a grease interceptor? 0 Yes No Don't Know
4. Date grease trap/interceptor was last cleaned (provide service record): 0 Don't Know
5. Does the plumbing system currently have a oiltwater separator? o Yes No Don't Know
6. Date oil/Water separator was last cleaned (provide service record): Don't Know
7. Is water used in the business process(washing,rinsing, cooling)? (0 Yes O No %Ak Don't Know
8. Does your business require a NPDES permit? O Yes o No Don't Know
Contact Person: v e- Phone Number:
Cell Phone: Fax. a.S3-q yfv-21 S3 E-mail: �f��_1/�_n►�i�e_[�vx���
The above information is complete and accurate to the best of my knowledge.I understand that any chans in the sewage
discharge from the site must be reported to the City of Arlington Public Works Utilities Division / Wastewater
Department immediately by contacting 3 60-403-3 526.
Authorized Signature: _ -- - �� Date: t ! i D�i� _
Office Use Only
Comments:
Date Received: ____ Survey Received By:
Assembly Required: ❑ DCVA ❑ RPBA ❑ AVB ❑ Other
Inspection Required: ❑ YES ❑ NO
Permit#: 236
Permit Date: 11/12/13
Permit Type: COMMERCIAL PLUMBING
Project Name: Scott Galvanizing
Applicant Name: Vinnie & Sons Plumbing
Applicant Address: 105-B W. Main St
Applicant, City, State, Zip: Puyallup, WA 98371
Contact: Dolores Shefler
Phone: 253-232-3298
Email: dd@vinnieandsonsplumbing.com
Scope of Work: Restrooms for break room
Valuation: 30000.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued:
Permit Expires:
Form Permit Type:
Status: COMPLETE
Assigned To:
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
ARLINGTON 9 1000746300000800 6010 199TH ST NE LAND HOLDINGS (Vacant)
Undeveloped
cant)Land
LLC (Va
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
C20.BUILDING All plumbing work
04/01/2014 FINAL completed per approved 04/01/2014 04/01/2014 z.Christopher Young Approved
plan.
Building drain is 4-inch.Aa
C 19.PLUMBING drainage fixtures sized per
11/13/2013 FINAL UPC and on 10'of head test. 11/13/2013 11/13/2013 z.Christopher Young Approved
Floor drains and cleanout
installed.
Plan Reviews
Date Review Type Description Assigned To Review Status
Owner decided to add urinals with flushometer valves
which requires a larger meter size.The ERU's will need to
11/12/2013 BLD be recalculated for a 1-inch for the warehouse only.A 2- z.Christopher Young
inch supply, 1-inch meter,and an 1-1/2 building supply is
required for the proposed demand.
11/12/2013 BLD PW-ADMIN-GIS
11/12/2013 BLD
11/12/2013 BLD No issues PW-SEW-REV
Note that the domestic meter has been upsized from 5/8 to
1"Also they are adding a separate 5/8 Irrigation meter by
11/12/2013 BLD doing so a 3/4 DCVA will be required at the meter PW-WAT-REV
location.
EA
11/12/2013 BLD
Fees
Fee Description Notes Amount
Mechanical Commercial Permit Table 4-7;Per Unit $229.00
Plumbing Plan Review Fees $350.00
Total $579.00
Attached Letters
Date Letter Description
11/14/2013 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
11/14/2013 Vinnie&Sons Plumbing 48207196 cc $579.00
Dolores Sheffer
Outstanding Balance $0.00
Notes
Date Note Created By:
This plumbing permit is for the break room restrooms.They are stubbing the line out from the
11/12/2013 building and not hooking up water or sewer yet.The owner will be in to pay the water and Amy Rusko
sewer hook up fees when they are put in at the road.See attachement for utility fees to be
applied.Plans not submitted for this review,but should follow approved plans.
Uploaded Files
Date File Name
11/12/2013 BLD236 Application.pdf
11/12/2013 Utility Fee Notes.pdf
Date: 04/08/2026
Permit#: 236
Permit Date: 11/12/2013
Review Date: 11/12/2013
Permit Type: COMMERCIAL PLUMBING
Review Type: BLD
Target Date: 11/15/2013
Scheduled
Time:
Completed 11/14/2013
Date:
Description: Note that the domestic meter has been upsized from 5/8 to 1"Also they are adding a separate
5/8 Irrigation meter by doing so a 3/4 DCVA will be required at the meter location. EA
Review
Status:
Assigned To: PW-WAT REV
Time In:
Time Out:
Hours:
Property Information
Parcel#: 00746300000800 ARLINGTON LAND HOLDINGS LLC
ARLINGTON LAND HOLDINGS LLC PO BOX 1600
6010 199TH ST NE ORTING, WA 98360
Zoning: 910 Undeveloped(Vacant) LandLot: Block:
Date: 04/08/2026
Permit#: 236
Permit Date: 11/12/2013
Review Date: 11/12/2013
Permit Type: COMMERCIAL PLUMBING
Review Type: BLD
Target Date: 11/15/2013
Scheduled
Time:
Completed 11/13/2013
Date:
Description: Owner decided to add urinals with flushometer valves which requires a larger meter size. The
ERU's will need to be recalculated for a 1-inch for the warehouse only.A 2-inch supply, 1-inch
meter, and an 1-1/2 building supply is required for the proposed demand.
Review
Status:
Assigned To: z.Christopher Young
Time In:
Time Out:
Hours:
Property Information
Parcel#: 00746300000800 ARLINGTON LAND HOLDINGS LLC
ARLINGTON LAND HOLDINGS LLC PO BOX 1600
6010 199TH ST NE ORTING, WA 98360
Zoning: 910 Undeveloped(Vacant) LandLot: Block: