Loading...
HomeMy WebLinkAbout3320 173rd Pl Ne_BLD200_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address:3320 173rd PI Permit#:200 Parcel#:00430200000400 Valuation: OWNER APPLICANT CONTRACTOR Name:COMPASS HEALTH Name:C&C Olympic Heating Name:C&C Olympic Heating Address:PO BOX 3810 Address:PO Box 2628 Address:PO Box 2628 City,State Zip:EVERETT,WA 98213 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:425-670-0277 Phone:425-670-0277 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR _ Name: C&C Olympic Heating Name: Address:PO Box 2628 Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:425-670-0277 Phone: LIC#: CCOLYCO974LE EXP: 6/2014 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL 1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. sS TAX CE:Sales tax acing to construction and construction materials in the City of ' n mus reported on your sales tax return form .and coded City f Arlington#310 !Q 4 grate Print Name Date Released By to CONDITIONS I/ THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 10/8/2013 Mechanical Permit Base Fee $100.00 10/8/2013 Mechanical Plan Review Fee $150.00 Total Due: $250.00 Total Payment: $0 00 Balance Due: $250.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 10/2/2013 Permit Number 200 Project Name Compass Health Permit Type Mechanical Site Address 3320 173rd PI Description Mechanical Valuation 0.00 Square Feet 0 Status Applied Permit Issued Permit Expires Phone 425-349-8700 _ Email wally.dahmen@compassh.org Occupancy Load Type of Construction Proposed Use Replace Heating&Cooling Equipment Number of Stories 0 Assigned To Amy Rusko Property Information Owner Information Parcel#:00430200000400 COMPASS HEALTH COMPASS HEALTH PO BOX 3810 3320 173RD PL NE EVERETT,WA 98213 Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# C&C Olympic Heating Inc Chris Cannon 425-670-0277 cncolympic@frontier.com I MECHANICAL CONTRACTOR Review _ Date Type Description Target Date Completed Date Assigned To Status 10/2/2013 Commercial Mechanical Mechanical Review 10/4/2013 Chris Young In Review 10/2/2013 Commercial Mechanical Mechanical Review 10/4/2013 Amy Rusko In Review Email History Date Emailed To 10/2/2013 cyoung@arlingtonwa.gov Uploaded Files I Upload File I Date File 10/2/2013 1 Delete ; . I �� . 1 I I I r COMMERCIAL MECHANICAL SUBMITTAL REQUIREMENTS Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone(360)403 3551 • FAX (360)403 3418 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS,AND ONE(1) SET OF WASHINGTON STATE ENERGY CODE APPLICATIONS. Type of Permit: ® Residential Apartment 91"Commercial Valuation Project Address: "�02­0 `��� �\ � Parcel ID#: Lot#: Subdivision 1 Project Description: t, Owner: `Q�°�*� ` ` Phone Number: Address: ` �� t �_-) City b!Q al Q_A State Zip Code Contact Person: Phone Number: 42S - Cell Phone: Fax: E-mail: c��l�t�l� ,l�. �1c Address: City: State: Zip Code: Please List Quantity of Fixtures Below: FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS FURNACE OVER 100K FLR FURN INSTALURELOCATE SUSPENDED HTR/UNIT HTR\ BOILER UP TO 3 HP APPLIANCE REPAIR APPLIANCE VENT/OTHER BOILER UP TO 4-15 HP TYPE I OR II HOOD VENTILATION EQUIPMENT BOLIER UP TO 16-30 HP AIR AHNDLING UP TO 10K CFM VENTILATION FANS BOILER UP TO 31-50 HP AIRHANDLING OVER 10K CFM OTHER VENTILATION SYSTEM BOLIER UP TO 51 HP AND UP INCINERATOR (AST)TANK STORAGE/PIPING ALL OTHER UNITS HEAT PUMP C (UST)TANK STORAGE/PIPING Contractor: CA \\ 'fiZlrte Number: ,oV) ' - � Address: Dn zc�sy Ua2b City: LH A State JL3= Zip Code: Contractor's License Number. }��C�~ '� 1 Expiration: u,1 \,4 • Provide applicable WSEC Worksheet(s)and appliance cut sheet(s)along with application • Provide applicable NFPA or other Reference Standard Material along with application I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described erty will otn-=rd ce with the laws, rules and regulation of the State of Washington. C Applicants Signature Date c ' Print Applicants Name FOR STAFF USE ONLY og�,� le,� OCT 0 2 2013 Permit# Accepted By Amount Received Receipt# lea 2 �. � �, ,., _ I I 5� �_J�.' r � COMMERCIAL MECHANICAL SUBMITTAL REQUIREMENTS Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone(360)403 3551 • FAX (360)403 3418 WHEN A MECHANICAL PERMIT IS REQUIRED The City of Arlington requires a mechanical permit before mechanical equipment is installed, altered, or replaced. Examples are installations or alterations of gas piping, replacement of any HVAC equipment, Heat Pumps, Exhaust Systems, Paint Booths, Above-ground and Under-ground tanks with piping, etc. The City of Arlington does not require a permit to replace an existing gas clothes dryer, stovetop ranges, ovens, or gas log if there is no gas piping installed or altered. MECHANICAL PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings. 5. All hoods (Type I and II). 2. Complete HVAC systems and AC units, heat 6. All Commercial gas piping. pumps, rooftop units or exhaust fans. 7. Any penetrations of fire resistive construction 3. Relocation of 10 or more diffusers. 8. All spray booths 4. Addition of fan coil units. SUBMIT TWO(2)COPIES OF THE FOLLOWING FOR MECHANICAL PLAN REVIEW: ❑ Mechanical plans or drawings. (Minimum plan size is 18" X 24" scale, %" scale for details.) ❑ Reflected ceiling plan showing and identifying ductwork, equipment, piping, supply diffusers, return air grilles and fire dampers. ❑ Roof plan showing equipment, ductwork, vents, roof access and equipment screening. .List of equipment and schedule. ❑ Engineered structural gravity and/or lateral force calculations for ALL rooftop units. ❑ A Commissioning Plan shall be submitted with the following: A detailed explanation of the original design intent Equipment and systems to be tested, including the extent of tests Functions to be tested, i.e. calibration, economizers, etc. Conditions under which test shall be performed, i.e. winter or summer design, full outside air, etc. Measureable criteria for acceptable performance ❑ Washington State Non-Residential Energy Code Forms. Structural Information: Please note that engineered structural gravity loads calculations are required for all rooftop units. If the unit is 440 lbs. or larger engineered structural lateral force calculations are also required. All Natural Gas Fuel Gas Piping is covered under the 2009 International Fuel Gas Code. Liquefied Petroleum Gas installations are covered by NFPA 54 (National Fuel Gas Code) and NFPA 58 (Liquefied Petroleum Gas Code). Gas water heater replacements require a permit and are regulated by the Uniform Plumbing Code 1 'c _ ; 1 0 Model Number YSH150F3RLA**0000000001 130000000000000000 Customer : Enter Customer Project : Enter Project Name : C &C2 Y4V General Unit function Gas/Electric Unit controls Reliatel Heating capacity Gas Heat- Low Design Airflow 5000 Min. Unit Operating Weight 1397.0 Evaporator Face Velocity 286 Rated capacity (AHRI) 140.00 Evaporator Face Area 17.50 ASHRAE 90.1 Yes Evaporator Fin Spacing 180 Max Unit Operating Weight 1799.0 Evaporator Rows 3 CoolingMain Cooling Entering Dry Bulb 80.00 Cooling Entering Wet Bulb 67.00 Ambient Temp 95.00 Tonnage 12.5 Ton Refrig charge (HFC-410A) - ckt 1 5.8 Evap Coil Leav Air Temp (DB) 58.52 Net Sensible Heat Ratio 0.76 Saturated Discharge Temp Circuit 118.75 2 Dew Point Temp 56.57 Gross Latent Capacity 34.09 Saturated Suction Temp Circuit 1 49.79 Fan Motor Heat 5.54 Net Sensible Capacity 110.44 Saturated Suction Temp Circuit 2 50.98 Gross Sensible Capacity 115.98 Cooling Leaving Unit WB 57.85 Ent Air Rel Humidity 51.08 Refrig charge (HFC-410A) -ckt 2 5.4 Evap Coil Leav Air Temp (WB) 57.33 Net Total Capacity 144.53 Saturated Discharge Temp Circuit 119.19 Gross Total Capacity 150.07 1 Cooling Leaving Unit DB 59.88 Main Heating Heating EAT 70.00 Heating Temp Rise 22.49 Output Htg Capacity w/Fan 127.54 Heating LAT 92.49 Output Htg Capacity 122.00 Motor/ BUILDING DEPARTMENT lob APPROVED /S Q DATE B!o �3 RECEIVED l NO ES AUTHORIZE OCT 0 2 2013 UNLEW APPROVED BY T BUILDING INSPECT R COA PERMIT CENTER Page I ��b O-Ln I ME 7MNE Voltage 208-230/60/3 Design ESP 0.500 Outdoor Motor Power 1138.1 Indoor Mtr. Operating Power 1.758 Compressor I RLA 22.40 Total Static Pressure 0.500 System Power 12.75 Indoor Motor Power 1.31 Condenser Fan FLA 3.20 Field Supplied Drive Kit Required None MOP 80.00 Component SP Add 0.000 EER @ AHRI Conditions 11.0 Compressor Power 10.30 Evaporator Fan FLA 10.60 Indoor RPM 689 Compressor 2 RLA 18.20 Exhaust fan power 0.750 MCA 64.00 IEER Rating 12.20 IDX cooiing Refrigeration controls Frostat Smoke detector Supply air smoke detector 10 11591 T4:0 mm" Enter Notes Page 2 i �� �� TRANE- 50 118" 0 6 7116" 48112" p O 0 p 29 5116' SINGLE POINT POWER ENTRY 57" 6" 106 11/16" 8 308" 716"❑IA.HOLE SERVICE GAUGE (UNITCONTROL PORT ACCESS 211116„ 013116" WIRE) 2"DIAHOLE (UNIT POWER WIRE) PACKAGED GASIELECTRIC-HORIZONTAL ISOMETRIC DRAWING END PANEL FILTER ACCESS -- DOOR SUPPLY RETURN 42112 L L O L H0RIZOPITALCONDENSATE ` ❑RWN COP(NECTION 1A 26 9116' 19 9116" 24 9116" 2" (25-41,IM)NPT 6 118" PACKAGED GASIELECTRIC-HORIZONTAL HORIZONTAL CONDENSATE DRAIN AND FILTER ACCESS AIR FLOW SIDE SIDE MEIN Page 1 i ,. i MAINE" ELECTRICAL ! GENERAL DATA GENERALPERFORMANCE Standard Motor Model(Ton): YSH 150F(12.5) Minimum CircuftAmpacity: 64 D Unit Operating Voltage Range: 187-253 Maximum Fuse Size: PD D UnitPranaryVoltage: 2.08 Idaximum(HACK)Circuit Breaker. 80 D tlnit Secondary Voltage: 230 UnitHertz: 60 Oversized Motor Field Installed Oversized Motor U nit P hase: 3 M CA: NIA M CA NfA MFS: N)A 4IFS: NIA EER: 11.0 MCB(HACR): NIA MCB(HACR): NIA GAS HEATUNG COMPRESSOR H eating M odeis: Low Circuit#1 12 H eating and 1 Stage In put(Btulh) 150,DDD 11 DO,000 Number. 2 Heating and 1 Stage Output(Btulh): 122,DDD 181,DD0 Minlldax-Gaslnput- Horsepower. S.fil4.5 Phase: 3 Pressure Natural or LP: 2.5114.D Rated Load Amps: 224118.2 GesCanneCtianPipeSize: 1/2' Locked RotorAmps: 149.DI137 6NDOOR MOTOR Oversized Motor Field Installed Oversized Motor Number: 1 Number: NIA Number. NIA Horsepower: 3 00 Horsepower. N;A Hp: NIA M otor Speed(RP M): 1,74D Motor Speed(RPM): NIA klotor Speed(RPM): NIA Phase: 3 Phase: KIA Phase: NIA Full Load Amps: 10.6 Full Load Amps: NLA FLA: NIA LockedRotorAmps: 81.0 Locked Rotor Amps: NIA LRA NIA OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (F field I nstal le d P owe r E xh aust) MOTOR Number. 2 Horsepower. NIA (Gas-Fired Heating only) Horsepower: 0.50 Motor S pe ad(R P Id): NIA 1.1 Phase: I•IJA H orsepower: 0.05 Phase: 1 atorspeed(RPMy: 1,100 Full Load Amps: NIA. Motor Speed(RPM) 3,500/2,8D6 P Phase: 1 Full Load Amps 3-2 LodcedRotarpmps: IJfA Full Load Amps: 05 Locked Rotor Amps: 8,8 Locked Rotor Amps: 0.78 FILTER REFRIGERANT Circuit#1 12 Type: Throwavay Type: R410 Furnished: Yes Factory Charge Number: 214 Circuit#1 12: 6.3lb1 5.9 to Recommended Size: 20`x20'k2"120'x25"x2` NOTES: 1 Id aximum(HACR)Circuit Breakersizing is for installations in the Unked States only 2.Refrigerant charge is an approximate value For a more precise value,see unit nameplate and service instructions. 3.Val ue doe s n of in d ud e P o%,&r Exh a ust Accesso ry. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated atA.HRI conditions and in accordance with DOE test procedures. Page 4 I I I I TRAWE CLEARANCE 48" / (121R2MM) CLEARANCE G(r (1524MM) i' CLEARANCE FROM TOP OF UNIT 7T (1828 8M M) O SUPPLY RETURN CLEARANCE 18" (457 2M M) CLEARANCE 38" (965.2M M) <�n HORIZONTAL-PACKAGED GAS/ELECTRIC CLEARANCE Page 5 it INSTALLED OPTIONS NET WEIGHT DATA .Accessorp Accessary ECoa om rer M o tariz e d Outside Air Damper M anus]Outside air Damper �vJ Oversized M atar High Static Drive Thru the Base Electrical Unit 1.1 ounted Circuit Breaker Unit M aun ted Disconnect P a vier E xhau st H krged Doors Zone Sensor QLPG Conversion Kit i -- Povered Convenience Outlet RoofCurb CORNER WEIGHT BASE UNITWEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET B) C @D E F i 1876 0 lb 1508.0 Ib 506 0Ib 390.016 275.0Ib 337.0Ib 55" 34' NOTE, 1 CORNER WEIGHTSARE GIVEN FOR INFORMATION ONLY. 2,TO ESTIMATE SHIPPING WEIGHT OF OPTIONfACCESSORIES ADD 5 LBS TO NET WEIGHT 3 NET WEIGHT OF OPTIONALACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES 4.WEIGHTS FOR OPTIONS NOT LISTED ARE¢5 LBS. 5 WEIGHT ARE OF BASE UNIT ONLY.FOR TOTAL WEIGHT,10 DIGIT FACTORY INSTALLED OPTION(ECONOLI IZER ANDtOR OVERSIZED MOTOR OR FIOPtACCESSORY WEIGHT MUSTBEADDED O � O d E ® e F 0 RIGGING AND CENTER OF GRAVITY Page 6 I General The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 1150F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with AHRI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal, service panels shall have lifting handles and no more than three screws to remove. All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units. Optional two inch pleated media filters shall be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. These are standard on all Voyager models. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane (field installed kit) and shall also comply with California requirements for low NOx emissions. The 121h- 25 tons shall have two stage heating (Gas/Electric Only). Microchannel coils The microchannel type condenser coil is standard for the T/YCD 12.5-25 ton standard efficiency models. Due to flat streamlined tubes with small ports, and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. All-aluminum construction improves re- cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin Page 7 i: MANE protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler- arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. Oversized motors shall be available for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control. When the discharge temperature rises above the protection limit, the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage. Defrost Controls Adaptive demand defrost shall be provided to permit defrost wherever coil icing conditions begin to significantly reduce unit capacity. Supply and/or Return Air Smoke Detector With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. Return Air Smoke Detectors require minimum allowable airflow when used with certain models. See the Installation, Operation, and Maintenance (IOM) manual for the models affected and the minimum allowable airflow required. This option is available on all downflow models. Page 8 i i `� Permit#: 200 Permit Date: 10/02/13 Permit Type: COMMERCIAL MECHANICAL Project Name: Compass Health Applicant Name: Compass Health Applicant Address: PO Box 3810 Applicant, City, State, Zip: Everett,WA 98213 Contact: Wally Phone: 425-349-8700 Email: wally.dahmen@compassh.org Scope of Work: Replace Heating & Cooling Equipment Valuation: 1000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/09/2013 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning COMPASS 659 Other 00430200000400 3320 173RD PL NE HEALTH Professional Services NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License C&C Olympic Heating Inc Chris Cannon 425-670-0277 PO Box 2628 MECHANICAL CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status CIO. packaged unit installed per 11/15/2013 MECHANICAL plan.Still pending L&I final 11/15/2013 11/15/2013 z.Christopher Young Completed ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status 10/02/2013 COMMERCIAL Ok to issue z.Christopher Young MECHANICAL 10/02/2013 COMMERCIAL Mechanical Review MECHANICAL Fees Fee Description Notes Amount Mechanical Base Permit Fee $100.00 Mechanical Commercial Plan Review Table 4-1 $150.00 Total $250.00 Attached Letters Date Letter Description 10/08/2013 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/09/2013 C&C check#163 14 Launa Black $250.00 Outstanding Balance $0.00 Uploaded Files Date File Name 10/02/2013 BLD 200 Application.pdf