HomeMy WebLinkAbout3320 173rd Pl Ne_BLD200_2026 CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
` PHONE; (360) 403-3551
BUILDING PERMIT
Address:3320 173rd PI Permit#:200
Parcel#:00430200000400 Valuation:
OWNER APPLICANT CONTRACTOR
Name:COMPASS HEALTH Name:C&C Olympic Heating Name:C&C Olympic Heating
Address:PO BOX 3810 Address:PO Box 2628 Address:PO Box 2628
City,State Zip:EVERETT,WA 98213 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036
Phone: Phone:425-670-0277 Phone:425-670-0277
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR _
Name: C&C Olympic Heating Name:
Address:PO Box 2628 Address:
City,State,Zip:Lynnwood,WA 98036 City,State,Zip:
Phone:425-670-0277 Phone:
LIC#: CCOLYCO974LE EXP: 6/2014 LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Commercial Mechanical CODE YEAR:
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
sS TAX CE:Sales tax acing to construction and construction materials in the City of ' n mus reported on your sales tax return form
.and coded City f Arlington#310 !Q
4
grate Print Name Date Released By to
CONDITIONS I/
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION
PERMIT FEES
Date Description Fee Amount
10/8/2013 Mechanical Permit Base Fee $100.00
10/8/2013 Mechanical Plan Review Fee $150.00
Total Due: $250.00
Total Payment: $0 00
Balance Due: $250.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Permit Information
Date 10/2/2013
Permit Number 200
Project Name Compass Health
Permit Type Mechanical
Site Address 3320 173rd PI
Description Mechanical
Valuation 0.00
Square Feet 0
Status Applied
Permit Issued
Permit Expires
Phone 425-349-8700 _
Email wally.dahmen@compassh.org
Occupancy Load
Type of Construction
Proposed Use Replace Heating&Cooling Equipment
Number of Stories 0
Assigned To Amy Rusko
Property Information Owner Information
Parcel#:00430200000400 COMPASS HEALTH
COMPASS HEALTH PO BOX 3810
3320 173RD PL NE EVERETT,WA 98213
Contractors
Contractor Name Primary Contact Phone Email Contractor Type License License#
C&C Olympic Heating Inc Chris Cannon 425-670-0277 cncolympic@frontier.com I MECHANICAL CONTRACTOR
Review _
Date Type Description Target Date Completed Date Assigned To Status
10/2/2013 Commercial Mechanical Mechanical Review 10/4/2013 Chris Young In Review
10/2/2013 Commercial Mechanical Mechanical Review 10/4/2013 Amy Rusko In Review
Email History
Date Emailed To
10/2/2013 cyoung@arlingtonwa.gov
Uploaded Files I Upload File I
Date File
10/2/2013 1 Delete
; .
I
�� .
1
I
I
I
r
COMMERCIAL MECHANICAL
SUBMITTAL REQUIREMENTS
Department of Community Development
City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone(360)403 3551 • FAX (360)403 3418
THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS,AND ONE(1)
SET OF WASHINGTON STATE ENERGY CODE APPLICATIONS.
Type of Permit: ® Residential Apartment 91"Commercial Valuation
Project Address: "�020 `��� �\ � Parcel ID#:
Lot#: Subdivision
1
Project Description: t,
Owner: `Q�°�*� ` ` Phone Number:
Address: ` �� t �_-) City b!Q al Q_A State Zip Code
Contact Person: Phone Number: 42S -
Cell Phone: Fax: E-mail: c��l�t�l� ,l�. �1c
Address: City: State: Zip Code:
Please List Quantity of Fixtures Below:
FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS
FURNACE OVER 100K FLR FURN INSTALURELOCATE SUSPENDED HTR/UNIT HTR\
BOILER UP TO 3 HP APPLIANCE REPAIR APPLIANCE VENT/OTHER
BOILER UP TO 4-15 HP TYPE I OR II HOOD VENTILATION EQUIPMENT
BOLIER UP TO 16-30 HP AIR AHNDLING UP TO 10K CFM VENTILATION FANS
BOILER UP TO 31-50 HP AIRHANDLING OVER 10K CFM OTHER VENTILATION SYSTEM
BOLIER UP TO 51 HP AND UP INCINERATOR (AST)TANK STORAGE/PIPING
ALL OTHER UNITS HEAT PUMP C (UST)TANK STORAGE/PIPING
Contractor: CA \\ 'fiZlrte Number: ,oV) ' - �
Address: Dn zc�sy Ua2b City: LH A State JL3= Zip Code:
Contractor's License Number. }��C�~ '� 1 Expiration: u,1 \,4
• Provide applicable WSEC Worksheet(s)and appliance cut sheet(s)along with application
• Provide applicable NFPA or other Reference Standard Material along with application
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described erty will otn-=rd ce with the laws, rules and regulation of the State of Washington.
C
Applicants Signature Date
c '
Print Applicants Name
FOR STAFF USE ONLY
og�,� le,� OCT 0 2 2013
Permit# Accepted By Amount Received Receipt# lea
2
�. � �,
,.,
_ I
I
5� �_J�.'
r �
COMMERCIAL MECHANICAL
SUBMITTAL REQUIREMENTS
Department of Community Development
City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone(360)403 3551 • FAX (360)403 3418
WHEN A MECHANICAL PERMIT IS REQUIRED
The City of Arlington requires a mechanical permit before mechanical equipment is installed, altered, or replaced.
Examples are installations or alterations of gas piping, replacement of any HVAC equipment, Heat Pumps, Exhaust
Systems, Paint Booths, Above-ground and Under-ground tanks with piping, etc.
The City of Arlington does not require a permit to replace an existing gas clothes dryer, stovetop ranges, ovens, or gas log
if there is no gas piping installed or altered.
MECHANICAL PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS
1. New Commercial Buildings. 5. All hoods (Type I and II).
2. Complete HVAC systems and AC units, heat 6. All Commercial gas piping.
pumps, rooftop units or exhaust fans. 7. Any penetrations of fire resistive construction
3. Relocation of 10 or more diffusers. 8. All spray booths
4. Addition of fan coil units.
SUBMIT TWO(2)COPIES OF THE FOLLOWING FOR MECHANICAL PLAN REVIEW:
❑ Mechanical plans or drawings. (Minimum plan size is 18" X 24" scale, %" scale for details.)
❑ Reflected ceiling plan showing and identifying ductwork, equipment, piping, supply diffusers, return air grilles
and fire dampers.
❑ Roof plan showing equipment, ductwork, vents, roof access and equipment screening.
.List of equipment and schedule.
❑ Engineered structural gravity and/or lateral force calculations for ALL rooftop units.
❑ A Commissioning Plan shall be submitted with the following:
A detailed explanation of the original design intent
Equipment and systems to be tested, including the extent of tests
Functions to be tested, i.e. calibration, economizers, etc.
Conditions under which test shall be performed, i.e. winter or summer design, full outside air, etc.
Measureable criteria for acceptable performance
❑ Washington State Non-Residential Energy Code Forms.
Structural Information:
Please note that engineered structural gravity loads calculations are required for all rooftop units. If the unit is 440
lbs. or larger engineered structural lateral force calculations are also required.
All Natural Gas Fuel Gas Piping is covered under the 2009 International Fuel Gas Code. Liquefied Petroleum Gas
installations are covered by NFPA 54 (National Fuel Gas Code) and NFPA 58 (Liquefied Petroleum Gas Code).
Gas water heater replacements require a permit and are regulated by the Uniform Plumbing Code
1
'c _ ;
1
0
Model Number YSH150F3RLA**0000000001 130000000000000000
Customer : Enter Customer
Project : Enter Project
Name : C &C2
Y4V
General
Unit function Gas/Electric Unit controls Reliatel
Heating capacity Gas Heat- Low Design Airflow 5000
Min. Unit Operating Weight 1397.0 Evaporator Face Velocity 286
Rated capacity (AHRI) 140.00 Evaporator Face Area 17.50
ASHRAE 90.1 Yes Evaporator Fin Spacing 180
Max Unit Operating Weight 1799.0 Evaporator Rows 3
CoolingMain
Cooling Entering Dry Bulb 80.00 Cooling Entering Wet Bulb 67.00
Ambient Temp 95.00 Tonnage 12.5 Ton
Refrig charge (HFC-410A) - ckt 1 5.8 Evap Coil Leav Air Temp (DB) 58.52
Net Sensible Heat Ratio 0.76 Saturated Discharge Temp Circuit 118.75
2
Dew Point Temp 56.57 Gross Latent Capacity 34.09
Saturated Suction Temp Circuit 1 49.79 Fan Motor Heat 5.54
Net Sensible Capacity 110.44 Saturated Suction Temp Circuit 2 50.98
Gross Sensible Capacity 115.98 Cooling Leaving Unit WB 57.85
Ent Air Rel Humidity 51.08 Refrig charge (HFC-410A) -ckt 2 5.4
Evap Coil Leav Air Temp (WB) 57.33 Net Total Capacity 144.53
Saturated Discharge Temp Circuit 119.19 Gross Total Capacity 150.07
1
Cooling Leaving Unit DB 59.88
Main Heating
Heating EAT 70.00 Heating Temp Rise 22.49
Output Htg Capacity w/Fan 127.54 Heating LAT 92.49
Output Htg Capacity 122.00
Motor/
BUILDING DEPARTMENT
lob APPROVED
/S Q DATE B!o �3 RECEIVED
l NO ES AUTHORIZE OCT 0 2 2013
UNLEW APPROVED BY T
BUILDING INSPECT R COA PERMIT CENTER Page I
��b O-Ln
I
ME 7MNE
Voltage 208-230/60/3 Design ESP 0.500
Outdoor Motor Power 1138.1 Indoor Mtr. Operating Power 1.758
Compressor I RLA 22.40 Total Static Pressure 0.500
System Power 12.75 Indoor Motor Power 1.31
Condenser Fan FLA 3.20 Field Supplied Drive Kit Required None
MOP 80.00 Component SP Add 0.000
EER @ AHRI Conditions 11.0 Compressor Power 10.30
Evaporator Fan FLA 10.60 Indoor RPM 689
Compressor 2 RLA 18.20 Exhaust fan power 0.750
MCA 64.00 IEER Rating 12.20
IDX cooiing
Refrigeration controls Frostat Smoke detector Supply air smoke detector
10 11591 T4:0 mm"
Enter Notes
Page 2
i
��
��
TRANE-
50 118"
0
6 7116"
48112" p O
0
p 29 5116'
SINGLE POINT
POWER ENTRY 57"
6"
106 11/16"
8 308"
716"❑IA.HOLE
SERVICE GAUGE (UNITCONTROL
PORT ACCESS 211116„ 013116" WIRE)
2"DIAHOLE
(UNIT POWER
WIRE)
PACKAGED GASIELECTRIC-HORIZONTAL
ISOMETRIC DRAWING
END PANEL
FILTER
ACCESS
-- DOOR
SUPPLY RETURN 42112
L L
O
L
H0RIZOPITALCONDENSATE `
❑RWN COP(NECTION 1A
26 9116' 19 9116" 24 9116" 2" (25-41,IM)NPT
6 118"
PACKAGED GASIELECTRIC-HORIZONTAL HORIZONTAL CONDENSATE DRAIN AND FILTER ACCESS
AIR FLOW SIDE SIDE MEIN
Page 1
i
,.
i
MAINE"
ELECTRICAL ! GENERAL DATA
GENERALPERFORMANCE
Standard Motor
Model(Ton): YSH 150F(12.5) Minimum CircuftAmpacity: 64 D
Unit Operating Voltage Range: 187-253 Maximum Fuse Size: PD D
UnitPranaryVoltage: 2.08 Idaximum(HACK)Circuit Breaker. 80 D
tlnit Secondary Voltage: 230
UnitHertz: 60 Oversized Motor Field Installed Oversized Motor
U nit P hase: 3 M CA: NIA M CA NfA
MFS: N)A 4IFS: NIA
EER: 11.0 MCB(HACR): NIA MCB(HACR): NIA
GAS HEATUNG COMPRESSOR
H eating M odeis: Low Circuit#1 12
H eating and 1 Stage In put(Btulh) 150,DDD 11 DO,000 Number. 2
Heating and 1 Stage Output(Btulh): 122,DDD 181,DD0
Minlldax-Gaslnput- Horsepower. S.fil4.5
Phase: 3
Pressure Natural or LP: 2.5114.D Rated Load Amps: 224118.2
GesCanneCtianPipeSize: 1/2' Locked RotorAmps: 149.DI137
6NDOOR MOTOR
Oversized Motor Field Installed Oversized Motor
Number: 1 Number: NIA Number. NIA
Horsepower: 3 00 Horsepower. N;A Hp: NIA
M otor Speed(RP M): 1,74D Motor Speed(RPM): NIA klotor Speed(RPM): NIA
Phase: 3 Phase: KIA Phase: NIA
Full Load Amps: 10.6 Full Load Amps: NLA FLA: NIA
LockedRotorAmps: 81.0 Locked Rotor Amps: NIA LRA NIA
OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER
(F field I nstal le d P owe r E xh aust) MOTOR
Number. 2 Horsepower. NIA (Gas-Fired Heating only)
Horsepower: 0.50 Motor S pe ad(R P Id): NIA
1.1 Phase: I•IJA H orsepower: 0.05
Phase: 1 atorspeed(RPMy: 1,100 Full Load Amps: NIA. Motor Speed(RPM) 3,500/2,8D6
P Phase: 1
Full Load Amps 3-2 LodcedRotarpmps: IJfA Full Load Amps: 05
Locked Rotor Amps: 8,8 Locked Rotor Amps: 0.78
FILTER REFRIGERANT
Circuit#1 12
Type: Throwavay Type: R410
Furnished: Yes Factory Charge
Number: 214 Circuit#1 12: 6.3lb1 5.9 to
Recommended Size: 20`x20'k2"120'x25"x2`
NOTES:
1 Id aximum(HACR)Circuit Breakersizing is for installations in the Unked States only
2.Refrigerant charge is an approximate value For a more precise value,see unit nameplate and service instructions.
3.Val ue doe s n of in d ud e P o%,&r Exh a ust Accesso ry.
4.Value includes oversized motor.
5.Value does not include Power Exhaust Accessory.
6.EER is rated atA.HRI conditions and in accordance with DOE test procedures.
Page 4
I
I
I
I
TRAWE
CLEARANCE 48" /
(121R2MM)
CLEARANCE G(r
(1524MM)
i'
CLEARANCE FROM
TOP OF UNIT 7T
(1828 8M M)
O SUPPLY
RETURN
CLEARANCE 18"
(457 2M M)
CLEARANCE 38"
(965.2M M)
<�n
HORIZONTAL-PACKAGED GAS/ELECTRIC CLEARANCE
Page 5
it
INSTALLED OPTIONS NET WEIGHT DATA
.Accessorp Accessary
ECoa om rer
M o tariz e d Outside Air Damper
M anus]Outside air Damper
�vJ Oversized M atar
High Static Drive
Thru the Base Electrical
Unit 1.1 ounted Circuit Breaker
Unit M aun ted Disconnect
P a vier E xhau st
H krged Doors
Zone Sensor
QLPG Conversion Kit
i
-- Povered Convenience Outlet
RoofCurb
CORNER WEIGHT
BASE UNITWEIGHTS CORNER WEIGHTS CENTER OF GRAVITY
SHIPPING NET B) C @D E F
i
1876 0 lb 1508.0 Ib 506 0Ib 390.016 275.0Ib 337.0Ib 55" 34'
NOTE,
1 CORNER WEIGHTSARE GIVEN FOR INFORMATION ONLY.
2,TO ESTIMATE SHIPPING WEIGHT OF OPTIONfACCESSORIES ADD 5 LBS TO NET WEIGHT
3 NET WEIGHT OF OPTIONALACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN
ORDERING FACTORY INSTALLED ACCESSORIES
4.WEIGHTS FOR OPTIONS NOT LISTED ARE¢5 LBS.
5 WEIGHT ARE OF BASE UNIT ONLY.FOR TOTAL WEIGHT,10 DIGIT FACTORY INSTALLED
OPTION(ECONOLI IZER ANDtOR OVERSIZED MOTOR OR FIOPtACCESSORY WEIGHT
MUSTBEADDED
O �
O
d
E ® e
F
0
RIGGING AND CENTER OF GRAVITY
Page 6
I
General
The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 1150F and 0°F in cooling as standard from the
factory for all units. Cooling performance shall be rated in accordance with AHRI testing procedures. All units shall be factory assembled,
internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence,
before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and
labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition.
Casing
Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with
a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet
construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal, service panels shall have lifting
handles and no more than three screws to remove. All exposed vertical panels and top covers in the indoor air section shall be insulated with a
1/2 inch, 1 pound density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be insulated with
1/2 inch, 1 pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the
curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs
up. The base of the unit shall have provisions for forklift and crane lifting.
Unit Top
The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage.
Filters
Two inch standard filters shall be factory supplied on all units. Optional two inch pleated media filters shall be available.
Compressors
All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall
have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll
compressors. All models shall have crankcase heaters, phase monitors and low and high pressure control as standard.
Crankcase Heaters
These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions.
These are standard on all Voyager models.
Refrigerant Circuits
Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports, and refrigerant line filter
driers factory installed as standard. An area shall be provided for replacement suction line driers.
Gas Heating Section
The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower
shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative
pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to
initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. After three
unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use
with natural gas or propane (field installed kit) and shall also comply with California requirements for low NOx emissions. The 121h- 25 tons shall
have two stage heating (Gas/Electric Only).
Microchannel coils
The microchannel type condenser coil is standard for the T/YCD 12.5-25 ton standard efficiency models.
Due to flat streamlined tubes with small ports, and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance.
Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better
compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. All-aluminum construction improves re-
cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin
Page 7
i:
MANE
protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at
the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be
leak tested to 465 psig.
Outdoor Fans
The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall
be permanently lubricated and shall have built-in thermal overload protection.
Indoor Fan
Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-
arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. Oversized motors shall be available
for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT).
Controls
Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide
an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident
control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor
and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better
building comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of
machine protection.
High Pressure Cutout
This option is offered for units that do not have High Pressure cutout as standard.
Discharge Line Thermostat
A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option
provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other
conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control. When the
discharge temperature rises above the protection limit, the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC
circuit. When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor.
When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage.
Defrost Controls
Adaptive demand defrost shall be provided to permit defrost wherever coil icing conditions begin to significantly reduce unit capacity.
Supply and/or Return Air Smoke Detector
With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. Return Air Smoke Detectors
require minimum allowable airflow when used with certain models. See the Installation, Operation, and Maintenance (IOM) manual for the models
affected and the minimum allowable airflow required. This option is available on all downflow models.
Page 8
i
i
`�
Permit#: 200
Permit Date: 10/02/13
Permit Type: COMMERCIAL MECHANICAL
Project Name: Compass Health
Applicant Name: Compass Health
Applicant Address: PO Box 3810
Applicant, City, State, Zip: Everett,WA 98213
Contact: Wally
Phone: 425-349-8700
Email: wally.dahmen@compassh.org
Scope of Work: Replace Heating & Cooling Equipment
Valuation: 1000.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 10/09/2013
Permit Expires:
Form Permit Type:
Status: COMPLETE
Assigned To:
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
COMPASS 659 Other
00430200000400 3320 173RD PL NE HEALTH Professional Services
NEC
Contractors
Contractor Primary Contact Phone Address Contractor Type License License
C&C Olympic Heating Inc Chris Cannon 425-670-0277 PO Box 2628 MECHANICAL
CONTRACTOR
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
CIO. packaged unit installed per
11/15/2013 MECHANICAL plan.Still pending L&I final 11/15/2013 11/15/2013 z.Christopher Young Completed
ROUGH-IN
Plan Reviews
Date Review Type Description Assigned To Review Status
10/02/2013 COMMERCIAL Ok to issue z.Christopher Young
MECHANICAL
10/02/2013 COMMERCIAL Mechanical Review
MECHANICAL
Fees
Fee Description Notes Amount
Mechanical Base Permit Fee $100.00
Mechanical Commercial Plan Review Table 4-1 $150.00
Total $250.00
Attached Letters
Date Letter Description
10/08/2013 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
10/09/2013 C&C check#163 14 Launa Black $250.00
Outstanding Balance $0.00
Uploaded Files
Date File Name
10/02/2013 BLD 200 Application.pdf