Loading...
HomeMy WebLinkAbout8110 207th St Ne_BLD117_2026 CITY OF ARLINGTON r, 238 N. OLYMPIC AVE- ARLINGTON, WA. 98223 PHONE;(360) 403-3551 BUILDING PERMIT Address:$110 2071h St Permit ll: 11.7 Parcel 11:31051100400600 Valuation: OWNER APPLICANT . CONTRACTOR Name:ARLINGTON SCIIL DIST 16 Name:Legends Rooting Co,Inc Namc,Legends Roofing Co,Inc Address:315 N FRENCH AVE Address:PO Box 371249 Addresv:.PO Box 371249 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Puyallup,WA 96373 City,State Zip:Puyallup,WA 98373 Phone: Phone:253-606.9070 Phone:253-606-9070 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LTC M I.iXI': LTC 11: I=XP: JOB DESCRIPTION PERMIT TYPE: RCROOf CODE YEAR: STORIES: CONST,TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGRI'1 TO COMPLY WITH CITY AND 'I'A' E.LAWS REMEA1119MRSTRUMON AND IN U ING' h E WORK AUI HO t.l' •D THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMP12NSA'IION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY TH)i BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE,OF OCCUPANCY HAS BEEN GRANTED. IBC110/TRCI10, S I.F TA N TICI::S Ics lax relating to construction and construction materials in the City ngton t ust be reported on your sales tax tetu i form and co rty o Arli one 10f. �0 �;t3�3 //�� natur Print Name / ' Date Rcicascd n Dat CONDITIONS THIS PERMIT AUTHORI'LS ONLY THE WORK NOTED.TILIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONS'rRUC'rION ON THE.PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL.REQUIRE.SEPARATE PERMISSION. PERMIT FEES Date Description Foe Amount 6114/2013 Building Permit Fee $3,390 78 Total Due: S3,390,78 Total Payment: 10,00 Valance Due: $3,390.78 CALL FOR INSPECTIONS BUILDING(3 1 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RE-ROOF I* PERMIT APPLICATION Department of Community Development City of Arlington•238 N Olympic Ave.•Arlington,WA 88223•Phone(360)403 3651 FAX(380)403 3418 Type of permit:(check one) C)Residential Commercial valuation, '38S, n?`3. 68 Project Address; 'R 1117 rQ.71"', %�--- � �t% ..-_ Parcel Ill#r ress;. Owner: tl� .�c+ S�trl'0\ �iS� G Phone Number. Address: Ciity; State; Zip Code'.-.---- Contractor: ��� � `� %� ���� l m �� Phone Number; - � - Pc) flit 3'71 2AN01 City: P" OY State: 16 Zip Code: q Y7 Address: it Contractor's License Number. i•'IE �E�P—C qU� Expiration: r'j�i Mule gdq Type of Reefing: � Number of Layers: Number of Squares: Class of Roofing:0 A 0 B 0 C installing or replacing sheeting: NO Work Scheduled 10 Begin- 710 vte 20 Work Scheduled to End: The following Is required for NON-Residential Buildings: �T r ;- .y o" i";t•f �Q All Non-Residential projects will require a site visit priorto the issuance of the p rmit for obvic existing roofing and number of existing layers. 1p Two copies of the Installation specifications and U.L.listed roof assembly. G_D Building square footage: 80300 (0 occupancy of Building: Office Retail Church T_ _RestaurantAh3k3.:�i2.r,:. � —School I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be acSnrda ce with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a me hcfd of fely accessing roof for inspection.A final inspection and approval shall be obtained when the re•roofing is complete. 2 -� AppI' ants Signature Dale � 11�g/ lut Print Applicants Name RECEIVED FOR STAFF U05ONLY JiJN 12 2013 CQVIDWER permit p Accepted By Amount Re calved Reeelpt 0 WEB Form-284 Page 1 of 1 711QCJY CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:8110 207th St Permit#: 117 Parcel#:31051100400600 Valuation: -OWNER APPLICANT CONTRACTOR Name:ARLINGTON SCHL DIST 16 Name:Legends Roofing Co,Inc Name:Legends Roofing Co,Inc Address:315 N FRENCH AVE Address:PO Box 371249 Address:PO Box 371249 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Puyallup,WA 98373 City,State Zip:Puyallup,WA 98373 Phone: Phone:253-606-9070 Phone:253-606-9070 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP JOB DESCRIPTION PERMIT TYPE: ReROOf CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I I OARC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City ington sl be reported on your sales tax return form and coded City of Arlington 43 10 1. L11 7113 Signature Print Name Date Released Dail CONDITIONS THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/14/2013 Building Permit Fee $3,390.78 Total Due: $3,390.78 Total Payment: $0.00 Balance Due: $3,390.78 CALL FOR INSPECTIONS _ BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RE-ROOF 40 PERMIT APPLICATION Department of Community Development City of Arlington•238 N Olympic Ave. •Arlington,WA 98223•Phone(360)403 3651 •FAX(360)403 3418 Type of permit:(check one) ® Residential Commercial Valuation: c) 79. (� g (20T" %r.6+ N CP Project Address: parcel ID#: Owner: C\ �� + Sc01 1 S-� r G� Phone Number: Address: City: State: Zip Code: _ Contractor: (LS e. C Phone Number: a2Z��5, 606 "C?b_70 Address: Po 3 I City: Ni Pt (1vP State: W� Zip Code: a g?,7� L E 6E N✓—C 9e4 0 !v Ex nation: �.f Contractor's License Number: R Type of Roofing: '✓ �e Number of Layers: 1 Number of Squares: Class of Roofing:)0 A ®B 0 C installing or replacing sheeting: NO Work Scheduled to Begin: To vie- 20 Work Scheduled to End: To 1�t2D The following Is required for NON-Residential Buildings: CTf Y OF ARLIKTON ft All Non-Residential projects will require a site visit prior to the issuance of the po rmit for obvi v1I�51 I�fC t Q existing roofing and number of existing layers. ���� f°N Two copies of the installation specifications and U.L.listed roof assembly. A P n F1 01 IV,F D ®Building square footage: @TI-0AV ancy of Building: Office DATE 113LlkBY ([)Occupancy ND CHANGES AUTHORIZED Retail Church UNLESS APPROVED BY TH Restaurant BUILDING INSPECTOR School _. _ �..__..._......�._._...... _ I hereby certify the above information is correct and that the construction on,and the occupancy and the use of the above described property will be acgWa ce with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a me d of fely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. Applicants Signature/�� Date l�n Y1/t`=t_�` 6 A - Print Applicants Name RECEIVED FOR STAFF USE �ONLY JUN 12 2013 Penult# Accept©d By Amount Received Receipt �U Ke�� En WEB Form-P84 Page 1 of 1 7110CJY .,�.�. ' M (. k�f f w i uY'~ ''rla'a ._"vs—o.j. iY'�n? { ...,,� '� ,� .z✓ 1 r�,u yvls i i 1 1 1 CertainTeed SAINT GOBAIN f_. .w • SERIES takes roofing g to a higher level �I Mall- RQ- J� '� -... f.•• t Nt.'s Cd�n a �-. w•-.... - - .... ._...-... .. "O tom. v� = i�,�,y�.y y� •--1- - •t � fly - r' SO MUCH DEPENDS ON YOUR ROOF. What's your roof protecting? Your family. Your possessions. The integrity of your house. All under one roof. All protected by the same Investment. When you choose LandmarkT" Series Shingles, you make the decision that assures the beauty, durability and security of your home for generations. Landmark Series takes roofing to a higher level. It's engineered to outperform ordinary roofing in every category, keeping you comfortable,. your home protected, and your peace-of-mind intact for years to come with a transferable warranty that's a leader in the industry. lion Landmark Series offers four levels CertalnTeed's enhanced lifetime of high performance shingles in m limited g warranty protects against ANY manufacturing weight and thickness. The heavier defects, which include aesthetic defects. the shingle,.the more depth, thickness and dimension it offers. All four Landmark TM TL offer the exceptional value of the • Trlple-layer protection industry's toughest fiber glass mat, ' 305 lbs. the strongest materials available and ' Max Def color palette the best warranty. • Lifetime limited warranty Landmark'" Premium • Dual-layer; h!gh performance • 300 lbs. • Max Def color palette Landmark Series shingles endure • Lifetime limited warranty time and weather beautifully. They Landmark'" Pro/architect so come with our exclusive StreakFighter'" • Dual-layer, high performance warranty, protecting your roof from • 270 lbs streaking that can be caused by • Max Def color palette airborne algae. • Lifetime limited warranty Landmark"" • Dual-layer durability • 240 lbs. I • Lifetime limited warranty i t I I ,� _ , 1 I 1 ':�• r�nt�.4JMAN^t'C�UIS.�'�Yln=�'��v�lt•�r�._ .... _ _ .. ' -- � - _. � 7 f i I! 2 � I i i� I 1 Three laminated layers of the Industry's most durable materials, providing a dramatically thick roofing product styled with the classic appeal of wood shakes. Like a real wood shake, it's truly dimensional In shape, with distinct butted edges and ' long-lasting curb appeal. Landmark TL costs a fraction of natural wood shakes, but the benefits don't end there. Unlike wood, It won't rot or decay; an.ct it offers excellent wind and fire resistance. z Landmark TL. Don't just choose it for the trlple-layer durability, originality, or even the cost advantages. Choose it for the power of Its position... high above all the rest. !� I I 3 • Three-piece laminated fiber glass construction • Rustic appearance of hand-split wood shakes 305 lbs. per square CertainTeed products are.tested to ensure the highest quality and complywith the following Industry standards: Fire Resistance: • UL Class A • UL certified to meet ASTM D3018 Type 1 Wind Resistance: • UL certified to meet ASTM D3018 Type 1 • ASTM D3161, Class F, 110 mph wind resistance Tear Resistance: • UL certified to meet ASTM,D3462 • CSA standard A123.5 Wind Driven Rain Resistance: • Miami-Dade Product Control>Acceptarice Quality Standards: • ICC-ES-ESR-1389 r • Lifetime limited transferable warranty ! against manufacturing defects an residential applications : • 50-year limited transferable warranty against manufacturing defects on group-Owned or commercial a.pp!lcat!cr:; • 15-year StreakFighter'" warranty • 10-year SureStart'" 1 protection � • 15-year 110 mph wind-resistance warranty • Wind warranty upgrade to 130 mph available. CertainTeed starter and CertainTeed hip and ridge required Soo actual warranty for specific datwils and limitations. f 4 �. 1 i CertainTeed Shingle Applicator ' s Manual Lan&iwk' Series and LandmrW TL 12 YOUR OBJECTIVE.—­--­­ BJECTIVE. T IMPORTANT:When installing Landmark TL on low slopes,one layer of winterGuard or an equivalent waterproofing shingle underlay. To learn the correct procedure for installing ment must be applied over the entire roof.Applying two layers of ,Landmark'shingles. felt shingle underlayment is not an acceptable alternative to WinterGuard.One layer of shingle underlayment meeting ASTM D4869 LANDMARK"SERIES AND LANDMARK'TL applied over the required wiinterGuard is also recommended. L 90' Landmark shingles have the installer-friendly NailTrak'"feature, which provides 11/2"wide nailing area and specially formulated L60•(21112) Quadra-Bond laminating adhesive(See Figure 12 3). STEEP S'°pe AppIr-ation Landmark Special is Impact resistant and is Specially 'Over manufactured with a reinforced fiberglass scrim to meet UL 2218 Class 4 impact resistance rating. STANDARD NOTE:Landmark Special must be installed over a clean deck(no Slope 2C1 22) roof-overs)to obtain the UL 2218 rating.It is strongly recommended L1S,5'(a112) that impact resistant cap shingles made from XT 30 IR shingles be LOW installed on all hips and ridges.Some insurance carriers may not slop°App,Fication consider the roof system as compliant to UL 2218 Class 4 without b low4112 Le.5'(2112) impact resistant cap shingles. , Z0•(0112) Landmark Solaris"shingles are ENERGY STAR'qualified roof Figure 12-1:Slope definitions. products that meet both solar reflectance and thermal emissivity requirements.Using CertainTeed's advanced roofing granules, THE ROOF DECK*MUST BE AT LEAST:3/8"(9.5 mm) Landmark Solaris reflects solar energy and radiates heat far better thick plywood,or 7/16"(11 mm)thick non-veneer,or nominal bran traditional roofing shingles—it can reduce the roof's temperature 1" (25 mm)thick wood deck. by as much as 20 percent In die summer.NOTE:Use matching Landmark Solaris hip and ridge shingles which are also solar reflective. COLD WEATHER CLIMATES (ALL SLOPES):Application of WinterGuard or its equivalent is strongly recommended whenever Landmark TL is unique because its patented Tri-Laminate' there is a possibility of ice build-up.Follow manufacturer's design combines three layers of material to provide a dramatically application instructions. thick shingle with a wood shake style. 1 With the exception of Landmark TL,closed-cut valleys are preferred FLASHING:Corrosion-resistant flashing must be used to help prevent i by CertainTeed when applying these shingles.Open valleys are leaks where a roof meets a wall,another roof,a chimney or other + recommended when applying Landmark TL;however closed-cut objects that penetrate a roof, valleys are also acceptable.Woven valleys are not recommended for SEALING:Shingle sealing may be delayed if shingles are applied Landmark TL because the trl-laminated shingle can buckle and become damaged when shaped into the valley.Nails are required in cool weather and.may be further delayed by airborne dust as fasteners for L=!dma r!s TL,st:ples are not allowed, accumulation.If any shingles have not sealed after 2 reasonab!e STANDARD OR STEEP SLOPES:CertainTeed recommends time period,hand sealing may be necessary. DiamondDeck"Synthetic Underlayment,Roofers'Select"High CAUTION:To prevent cracking,shingles must be sufficiently warm Performance Underlayment,or shingle underlayment meeting ASTM to allow proper forming for hips,ridges and valleys. D226,D4869 or D6757.Take care to ensure sufficient deck ventila- WARRANTY:These shingles are warranted against manufacturing tlon when DiamondDeck or other synthetic underlayment is installed, defects and are covered by SureStart"protection.See the warranty i Follow manufacturer's application instructions, itself for specific details and limitations. 1 LOW SLOPES:One layer of CertainTeed's WinterGuard" Waterproofing Shingle Underlayment(or equivalent,meeting ASTM * For technical quesilons,Information an acceptable H D1970)or two layers of 36"wide felt shingle underlayment(Roofers' altemative application methods and materials, E W Select or underlayment product meeting ASTM D226,D4869 or or a copy of the product warranty,contact the N = D6757)lapped 19"must be applied over the entire roof;ensure sources listed below: a s sufficient deck ventilation.When DiamondDeck or other synthetic Your supplier or roofing applicator underlayment is installed,woollier--lap at least 20"and ensure CertainTeed Home Institute 800-782.8777 ✓ ✓CertainTeed-RPG Technical Services 800-345-11451 ✓ I ✓ I ✓ sufficient deck ventilation. 110 FASTENING LOW AND STANDARD SLOPE — LANDMARK Shingle f 12" 143/4" 12" Roo �--(305 mm)----••—(375 mm)----(305 mm)--1 Prppper Crooked Under- Over. I"-1"(25 mm) Release Tape 1"(25 mm)--I Ulf Driven Driven 11�2•• ^ . Nailable Figure 12.2.•Proper and improper wriiirg. Area 1:11PORTANT:For decks 3/4" (19 mm) thick or thicker,nails must go at least 3/4" (19 mm)into the deck.On thinner decks,nails must LANDMARK TL go at least t/8'•(3.2 mm) through the deck. 13111' 13" 131/2" Nalls must be 11-or 12-gauge roofing nails,corrosion-resiarnt, 1 —(343 mm)----(330 mm)----(343 mm)—►j with at least 3/8" (9.5 mm)heads,and at least I" (25 mm)long. LandMark TL requires nails at least 11/4"long. I"-1"(25 mm) 1"(25 mm)--I -- FA RX ^" _- tNwAeatfor s S Use our nails ore �ull shingle-- Figure 12.4. ttai:Area for �A,,'.oid PWciny stelpslopcs ..J,AI q STEEP SLOPE s Lino Release Tape Use six nails and four spots of asphalt roofing cement for every full laminated shingle.See below,Asphalt roofing cement should meet .................:: ..;;;... ASTM D 4586 Type If.Apply 1"spots of asphalt roofing cement under each corner and at about 12"to 13"in from each edge. FRONT LANDMARK ,tNailing Lines — 12" ,—143/4" --12"- -+^ (305 mm) (375 mm) (305 mm) I t BACK 1-1"(25 mm) Release Tape — _ Nail Area Sealant Strlps Far Steep t .I I-- UNDERSIDE (25 mm) I ———— (25 mm) I OFTOP Quadra-Bond Roofing Cement LAMINATE LAYER LANDMARK TL t Four laminating adhesive strips for a stronger bond, i0:1343m 3 F2, i3 —�j/2„------��� ( m) (30 mm) (343 mm) I i Figure 12-3: a wider call area and �" 1"(25 mm) 1"(25 mm)�t extra slrongQuadra Bond construction. I I I _ I I t•,�I I-- (25 mm) (25 mm) , Rooting Cement I E Figure 12-5.•Use six nails and four spots of asphalt roofing cement on steep slopes. CAUTION:Excessive use of roofing cement can cause shingles to blister. CERTAINTEEtD SHINGLE APPLICATORS MANUAL Cfiap1er12 111 - 1ST COURSE:Apply a full shingle at the lower left corner of the TWO CLEAN-DECK APPLICATION METHODS roof.Make the lower edge and left edge lie flush with the edges of the FOR LANDMARK AND starter course(Figure 12-7), LANDMARK TL SHINGLES _-4F_ 2ND THROUGH STH COURSES: f1VROURSE DIAGONAL METHOD(6"AND 11") CAUTION!Failure to follow instruction steps 1-5 below will bring FIVROURSE DIAGONAL METHOD(55/8"AND 111/4") joints too close together and may cause unattractive patterns! NOTE:The 6'and I I"method is shown below.The 55/8"and 1 11/4" 1,Cut 6"off the left end of the first shingle and save this piece for later method follows the same application instructions as the 6"and I I" use.Apply the 323/4"(34"for Landmark TL)long piece over and method except the dimensions of the shingle cut-offs in the second and third courses are 55/8"and 11 t/4"respectively. above the first-course shingle.Leave the bottom 55/8"tab portion of CAUTION:Use of other installation methods may result in an the first-course shingle exposed. objectionable pattern. 2.Cut I off the first shingle of the third course and save this for later.install the 273/4" (29"for Landmark TL)long piece over and PREPARING THE DECK: above the second-course shingle, ♦Apply underlayment as required.CertainTeed suggests that a 3.Apply the previously removed I long piece over and above the layer of shingle underlayment be applied.For UL fire rating, third-course shingle. underlayment is generally required.Apply flat and unwrinkled. 4.Apply the previously removed 6"long piece from the second ♦Snap chalkllnes to assure shingles will be correctly aligned. course over and above the fourth-course shingle. Expose ail shingles 55/8" (H 3 mm.). 5.Install a full shingle against the right edge of each shingle in STARTER COURSE: courses one through five. 1.Use CertainTeed Swihstari Starter,or three-tab self-seating shingles CONTINUING UP THE ROOF: with the lower tab portions removed.Be sure that the starter 1.Beginning again with a full shingle,repeat the five-course pattern shingles are at least 75/8"In height.Mgure 12-6), up the left rake,(Flgure 12-8,e). 2.Fill-in courses across the roof in a stepped diagonal fashion using full shingles.fture 12-8,A).Do not run courses straight across. Starter Shingle 75/8" iMPORTANll Do not align Joints of shingles closer than 31/2" 1 � from one another. r-----,r-- -- - ----- I Removed these p110rI a n s Figure 12-6'Make starter shingles that are 75/8"in height. �O0x4� 2.For the first starter,cut 6"from one side of the starter shingle. 3.Apply the remaining piece to the lower left corner of the roof. Make sure there is t/t"overhanging the rakes and eaves if drip edge is being used. If you are not using drip edge,make the ,\ overhang 3/4". �p o e 1S'*A o 4.Use full length starter shingles for the rest of the course. ��•� 4\�\ ���C4��e ��a LOSS\COU�S� b ' Sa�t6o�°��o I Figure 12-7:App4vUtg the first 5 courses of Landmark. Note:The Landmark 9'L dimensions dtjjer. 112 Chapter12 CERTAINTEED SHINGLE APPLICATORS MANUAL r Figure 12-8.`Five-Course Diagonal Method,,installation sehemalic. I For capping hip and ridge,apply CertainTeed "Accessory"shingles of a like color. I 0 pp\too I I �P\ooe�aec�\ V�pe�\ayn`e�� i I I I I 1 I I I Air Flow ! Through Soffit I Provide adequate ®� ventilation deck under the roof deck to prevent harmful condensation In winter and heat bulld•up in summer. Line valley by centering I , 15 1 IimideI I IWaterproofingI IUnderlayrnent or •I \,,x \O1 to I on as s val 9/0 e\\aa I I a�0a�a s o/ 00/a� I I 2/3p�0j F b0 0�noi a\�a\vi\\o\ I I I a ha f��ryl y o9�0in. llegt01/0 0/ ` shig9/e 21cut Shin91eS bapkfr mm) Valley rlhe Algure 12 9•Highlight of closed-cut valley details. CBRTAINTEED SHINGLE APPLICATORS MANUAL Chapter12 113 it CHIMNEY fLA5HING HIPS AND RIDGES SHADOW RIDGE'ACCESSORY SHINGLES Metal Step Flashing Shadow Ridge shingles have an accented shadow line that is designed to complement these shingles.Simply fold along the pre-cut lines and detach Individual cap pieces.Save valuable Installation time compared 2' S0 mm , • 7 5/fl° to cutting 3-tab shingles. ( 193 mm Minimum � ( ) 3" (75 mm) Minimum figure 1240.•Step flashing minimum dimensions. R"p Fold 10;f - Figure 12-12.-Shadow Ridge accessor,,shiq-Les detach eas•'y f o;;z counter flashing three-piece units to make72 individual cappieces over step flashing There are 24 three-piece units in each Shadow Ridge bundle, providing 72 individual caps that will cover 30 linear feet(333/4 linear feet,Metric)of a hip or ridge.Each English dimension cap piece is 12"by 12" (Metric caps are 131/4"by 97/8")and features clipped corners on the bottom edge of the exposed portion. Fasten /am,� Flashing APPLICATION IS AS)FOLLOWS: i To Roof 1,Apply shingles up to the hip or ridge on both sides,then trim Counter (�. 1 flush. i Flashing NOTE:The last course of shingles should have an exposure of 5" (55/8"for metric)or less when the shingle cap or ridge vent is �i fasiened in place.Otherwise,a potential water leak could occur at exposed shingle end joints.The figures used in this section illustrate Ap�p��F/vshii�9 the application of accessory shingles over a ridge vent;application directly to the roof deck is very similar. 12' Apply Over (305rnm) Starter Shingle t I Starter Shingle I I #"lgaee 12-11:Flashing around a chimney Figure 12-13.•Apply a full cap shingle over the starter piece, flush with the bottom and side edges of the starter. j 2.Install caps beginning at the bottom of a hip or at either end of a ridge.Apply a starter piece that has the bottom 5"(55/8"for TWO ROOF-OVER METHODS metric)removed(Figure 12-18).Fasten the starter with two nails F 0 R LANDMARK AND located about 3"from the rake edge,and 1"in from each side LANDMARK TL SHINGLES edge.Make sure fasteners used to apply caps penetrate at least 3/4"into or through the decking. The same methods used for clean—deck application of these shingles NOTE:To assist in proper alignment when ridge vent is not used, are used for roof•overs.Application of these shingles over English snap a chalk line parallel to the hip or ridge along the line where dimension shingles is not recommended—due to the high cost of the side edges of the cap shingles should be. workmanship and greater risk of worker error. 114 Chapicr12 CERTAINTEED SHINGLE APPLICATORS MANUAL 3.Apply a full cap single over the starter(Figure 1248),and place 121, 1 9o5mn'1 fasteners at S 5/8"(6/4"for metric)up from the exposed bottom �f Laying Notch edge and 1"in from each side,Nails must not be exposed on the finished roof,All nail heads must be driven straight and must not I cut Into the shingle surface. I 5"(125m��) i ICI 5"(125mrnl I Fxposur© Exposure I 1 ail ' Figure 12-16.•Use laying notches to center shingles on hips and Figure 12-14.•instal!cap shingles at their correct exposure ridges,and to locate the correct exposure. and cover all fasteners. NOTE:Each cap has a laying/alignment notch at the top edge to _ 4®_ center the piece on the ridge line,and two notches on each side MOUNTAIN RIDGE HIGH-PROFILE to indicate the correct exposure and shadow-line placement HIP AND RIDGE ACCESSORY (Figure 12-19).The side notches of the cap being applied should be aligned with the top edge of the previously applied cap. Use Mountain Ridge accessory shingles to cover hips,ridges or 12" rake edges.One box will cover 20 linear feet.To prevent damage to (305mm) shingles during application,they must be sufficiently warm to allow - 6' --- 6' proper forming. (150mm) (150mm) FASTENING IIIIPOR'I'AN1`.Use two nails to fasten each shingle.Nails must be Notch for minimum 13/4" (45 nrrn)long.For the 4'(100 mm)starter Centering shingle,place fastener 1" (25 mm)in from each side edge and about 12" - 2" (50 mm)from the rake(or eave)edge,making sure the fastener (305mm) I goes 3/4"into the deck or all the way through.For each full Mountain Notches for Alignment the Top Edge of the Previous 7" Ridge shingle,place fasteners 85/8" (219 mm) up from its exposed Cap for 5•(125mm)Exposure (1� m) butt edge and 1"(25 mm)in from each side edge. Sealant English Dimension ✓ I 97/8" ate (250mm) --415/16' 415/16"-- Sealant � (125mm) (125mm) 4-Starter tc —s \ I c-iAC6 Noh for Centering 13114" - 7 (337mm) Notches for Alignment to 5 the lop Edge of the Previous 7 /8 Figure 12-17•Hip and ridge application. Capfor55/8'(141mm)Exposure (196mm) ! t � E r Metric Dimension Figure 12-15 r Each Shadow Ridge shingle has a centering notch and two side-alignment notches to help emune proper placement CERTAINTEED SHINGLE APPLICATOleS MANUAL Chapter12 115 HIP,RIDGE AND RAKE SHINGLE APPLICATION FASTENING Apply the primary field roofing up to the hip or ridge from both IMPORTANI�Use TWO nails to fasten each shingle.Fasteners must sides of the roof and trim flush or lap over one side,not more than be minimum 1-3/4" (45 mm)long. half the width of a Mountain Ridge shingle. For the starter shingle,place fastener 1"in from each side edge and Assure that the installed Mountain Ridge shingles properly cover about 2"up from the starter shingle's exposed butt edge,making hip and ridge field shingles on both sides and the field shingles sure fastener goes 3/4"into the deck or all[lie way through the deck. applied along rake edges.For a rake edge installation,cut the field (see Figure 12-19).For each full Cedar Crest shingle,place fasteners shingles flush to the rake edge.Apply Mountain Ridge shingles 8-5/8"up from its exposed butt edge and I"in from each side edge ensuring they fit securely against the rake hoard.To assist in (see Figure 12-20). proper alignment,snap a chalk line parallel to the hip, ridge or rake along the line where the side edges of the , Mountain Ridge shingles should fall. Prepare a 4"Starter shingle by cutting off the Iower 8"color granule butt portion of one Mountain Ridge shingle.Apply the 4" starter piece(with sealant nearest the outer edge)over the bottom corner of the hip or rake,or on either end of the ridge,overhanging s„102,r"'s" the corner or end by approximately t/z"and bending the starter shingle along its centerline to form into place(see figures below.) Install a nail on each side about 2"up from the starter shingle's exposed butt edge and 1"in from each side edge of the shingle.The K m\ 8"piece that was cut off may be used to finish the opposite end of hip,ridge or rake. Next,apply a full Mountain Ridge shingle over the Installed starter shingle,bending it along its centerline and forming into place over the hip,ridge or rake,flush with the bottom and side edges of the starter shingle.Install a nail on each side of the shingle 85/s"up from the bottom edge and I"In from each side edge. Figure 12-19,Apply a full cap shingle over the starter shingle. Continue application of the Mountain Ridge shingles along the hip, ridge or rake as shown.Expose Mountain Ridge shingles 8",covering all fasteners. CEDAR CREST MEDIUM-PROFILE HIP AND RIDGE ACCESSORY SHINGLES Use Cedar Crest accessory shingles to cover hips and ridges. scs ✓\1�0rm\ Carefully separate the three-piece units prior to application,by first folding along the pre-cut lines and then detatching the pieces see Figure 12-18).No cooing is necessary.There are 30 individual � shingles(10 three-piece units)In each bundle.One bundle will cover 20 linear feet.Each 12"x 12"shingle has a shadowline that Is a design feature which is visible when applied properly.To prevent shingle damage during application,they must be sufficiently warm to / ! a!!:prope.,fern,;n, \ \� Three-piece unit Figure 12-20'Install cap shingles at an 8"exposure { and fallen u4th one nail on each side as shown. l i i Shadowfine 7 2 3 Ii t Figure 12-18•.Separale to make 3 cap sh-Vies 116 Chapterl2 CERTAINTEED SHINGLE APPLICATORS MANUAL l i i IMPORTANT`.high Wind Instructions.In order to achieve the CEDAR CREST APPLICATION AS TM D3161 Class'T"Wind Resistance Classification each"hip and ridge"shingle must be both 1)fastened with nails as shown and 2) Apply primary roofing up to hip or ridge on both sides of roof and hand-sealed with two 1/4"wide beads of either BASF"SonolasUc° trlm flush.Ensure that the Cedar Crest shingles will adequately cover NPI'Adhesive"or Henkel"PLO Polyurethane Roof&Flashing Cement" the top course of the shingles on both sides of the hip or ridge. applied from the middle of the shingle's raised overlay on the top piece Prepare a 4""starter"shingle by cutting off the lower 8"color gran- and extending approximately " ule portion of one Cedar Crest shingle.Apply the 4"starter piece with 4" along the sides of the �^a� ^o aanawa raised overlay edge over the bottom corner of the hip or to either end headlap along a line 3/4"-1" of the ridge,overhanging the corner or end by approximately 1/2" in from each side edge of the 1W 4- and bending the starter shingle along its centerline to form into place shingle's headlap as shown. (see Figure 12-19),Install a nail on each side about 2"up from the Immediately align and apply 3/4' starter shingle's exposed butt edge and 1"In from each side edge of the next overlying shingle, the shingle. gently pressing tab sides into _ �. Then apply a full 12"x 12"piece over the starter,bending the shingle adhesive.Only one side of Dabafaspmlt """ I along its centerline and forming it into place over the hip or ridge, [he double thickness tab is `�s�nmyeiayan i• flush with the bottom and side edges of the starter shingle.Fasten laminated together; f secure Figure 12 21:Hand seal caps with two nails minimum 1-3/4"long with one nail on each side of the other side,after folding the shingle over die ridge and as Si,,,,,,,, shingle 8 5/8"up from the butt edge and i"In from each side edge nailing into position,a 1"diameter spot of either NP1 or PL adhesive (see Figure 12-20).Continue application of Cedar Crest shingles up the hip or along must be applied between the shingle layers as shown.Immediately align the ridge,forming each shingle over the hip or ridge,and fasten as and apply the next overlying shingle,gently pressing tab sides into shown in Fastening.Expose Cedar Crest shingles 8" covering all adhesive. g• p 8l � g fasteners. To assist in proper alignment,snap a chalk line parallel to the hip or ridge applying along the line where the side edges of the Cedar Crest shingles should be. t f t 1 I i (I 1 Here's a Tip..,In the winter put hip and ridge cap shingles in your truck with the heater blasting for 20 minutes so the caps don't crack when farmed. (Thanks to Mark Dulx,Richmond,Mi.) CERTAINTEED SHINGLE APPLICATORS MANUAL Chapler12 117 1 Permit Information - - - - Date 6/13/2013 Permit Number 117 Project Name Kent Prairie Elementary Permit Type ReRoof Site Address Description ReRoof Valuation 385080.00 Square Feet 0 Status Applied _ Permit Issued Permit Expires Phone Email Occupancy Load Type of Construction Proposed Use School ReRoof Number of Stories 0 Assigned To Amy Rusko Property Information Owner Information Parcel#.31051100400600 ARLINGTON SCHL DIST 16 ARLINGTON SCHL DIST 16 315 N FRENCH AVE 8110 207TH ST NE ARLINGTON,WA 98223 Contractors - - — Contractor Name Primary Contact Phone I Email Contractor Type License License ft Legends Roofing Co, Inc Ron McCullah 253-606-9070 ronm@legendsco.com CONTRACTOR f l Review Date Type Description Target Date Co feted Date Assi ned To Status 6/13/2013 BLD Commercial ReRoof 6/11/2013 IChris Young In Review 6/13/2013 BLD Permit Tracking 6/19/2013 jAmy Rusko In Review Uploaded Files f Upload File:21 Date File 6/13/2013 Kent Prairie ReRoof.pdf Delete AhL RE-ROOF qW PERMIT APPLICATION Department of Community Development City of Arlington•238 N Olympic Ave. •Arlington,WA 98223•Phone(360)403 3661 -FAX(360)403 3418 Type of permit: (check one) ®Reside �'$ Residential ,-+ Commercial Valuation: b7`�, (0�3 6 I�7 aoTh S�rlca4 N li Project Address: Parcel ID#: Owner: r``mac, ScUK�01 i S-� r G+ Phone Number: Address: City: State: Zip Code: Contractor: e C Phone Number: 0Z9&- &06"90-70 Address: PC) 3 I t City: N X"'J --State: W C4 Zip Code: 9 — Contractor's License Number: L E 6E r-J ek- q94 0 N Expiration: J w 2-D.1 Lf— Type of Roofing: gL'r Number of Layers: r Number of Squares: Class of Roofing:0 A a B tm C installing or replacing sheeting: NO Work Scheduled to Begin: 'Ty he 20 Work Scheduled to End: The following Is required for NON-Residential Buildings: `^.'� (�� ` All Non-Residential projects will require a site visit prior to the issuance of the p it for�VibuS 819Qbf fatARLI Ri T(A existing roofing and number of existing layers. BUILDING DEPARTMENT go Two copies of the installation specifications and U.L.listed roof assembly. /� P P P�V F D ®Building square footage: &�00 /� -- -'---- Occupancy of Building: Office DATE _! BY Retail O CH NUES AUTHORIZED Church UNLESS APPROVED BY T Restaurant� School BUILDING INSPECTOR� I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be ac xda ce with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a me d of fely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. A. _ r Applicants Signature Date /ZO h W6�II Print Applicants Name RECEIVE® FOR STAFF USE ONLY JUN 12 2013 Permit# / Accepted By Amount Received Receipt* C`O 14e' yGWER WEB Form-284 Page 1 of 1 7l10CJY 3 Cl ,6OFFICE� COPY T i w • • �l+ mow,".�� � :ry,.�' z�n {{LLgq wy.4 ,k.. } _^�• 4a _.o t 1 i CertainTeed SAINT GOBAIN i LAVDJMIN SERIES takes roofing g to a higher level M «R 'L Y ir�Ilw .• L - ..- ....... , � �w� AMA^ _. • . -'1 Yk '3 yrY ^ I SO MUCH DEPENDS ON YOUR ROOF. What's your roof protecting? Your family. Your possessions. The integrity of your house. All under one roof. All protected by the same investment. When you choose Landmark'" Series Shingles,you make the decision that assures the beauty, durability and security of your home for generations. Landmark Series takesmofing to a higher level.- It's engineered to outperform ordinary roofing in every category keeping you comfortable, your home protected, and your peace-of-mind intact for years to with a transferable warranty that's a leader in the industry. a 4Y` I Landmark Series offers four levels CertalnTeed's enhanced lifetime limited i of high performance shingles in warranty protects against ANY manufacturing f weight and thickness. The heavier defects, which include aesthetic defects. the shingle,.the more depth, thickness and dimension it offers. All four Landmark'" TL offer the exceptional value of the • Triple-layer protection ; industry's toughest fiber glass mat, • 305 lbs. i the strongest materials available and • Max Def color palette the best warranty. • Lifetime limited warranty Landmark`" Premium • Dual-layer, high performance � • 300 lbs. • Max Def color palette Landmark Series shingles endure • Lifetime limited warranty j time and weather beautifully. They Landmark'.m Pro/architect so come with our exclusive StreakFighter'" • Dual-layer, high performance warranty, protecting your roof from • 270 lbs. _? streaking that can be caused by • Max Def color palette airborne algae. • Lifetime limited warranty Landmark"" • Dual-layer durability • 240 lbs. • Lifetime limited warranty { t ` . I I'.Un,rti Co:,�hyGra� Ageu 9Irk S, Old rvUrttin , I i f (I i 1 I Three laminated layers of the Industry's i most durable materials, providing a drarnatically thick roofing product styled with the classic appeal of wood shakes. E Like a real wood shake, it's truly dimensional ! in shape, with distinct butted edges and i{ long-lasting curb appeal. Landmark TL costs a fraction of natural wood shakes; but the benefits don't end , there. Unlike wood, It won't rot or decay; and ; it offers excellent wind and fire resistance. i Landmark TL. Don't just choose it for the triple-layer,durability, originality, or even the } cost advantages. Choose It for the power of 1 its position... high above all the rest. I I 3 1 • Three-piece laminated fiber glass construction • Rustic :.:a � `'' •� ••` . ppearanaeofhand-split ':':-•�,<•: wood shakes - • 305 lbs. per square CertalnTeed products are tested to ensure the highest quality and comply with the: following Industry standards: Fire Resistance: • UL Class A • UL certified to meet ASTM 03018 Type 1 Wind Resistance: • UL certified to meet ASTM D3018 Type.1 • ASTM D3161, Class F, 110 mph -, wind resistance Tear.Resistance: • UL certified to meetASTM D3462 • CSA standard A123.5 Wind Driven Rain Resistance: • Miami-Dade Product Control Acceptance - Quailty Standards: • IOC-ES-ESR-1389 • Lifetime limited transferable warranty against manufacturing defects on residential applications 50-year limited transferable warranty against manufacturing defects on group-ow:red or commercial.eppllcatic^s ! • 15-year StreakFighter" warranty • 10-year SureStart" I Protection '::: •.� : - � • 15-year 110 mph wind resistance warranty f • Wind warranty upgrade to 130 mph ; available. CertalnTeed starter.and CertainTeed hip and ridge required See actual warranty for specific details end limitations. i I CertainTeed Shingle Applicator ' s Manual Lan rkV4 SelieS and Landmark" TL 112 YOUR OBJ$CTIV$' � IMPORTANT.When installing Landmark TL on low slopes,one layer of WinterGuard or an equivalent waterproofing shingle underlay- To learn the correct procedurefor installing ment must be applied over the entire roof.Applying two layers of Landmark'Shingles, felt shingle underlayment is not an acceptable alternative to WinterGuard.One layer of shingle underlayment meeting ASTM D4869 LANDMARK"SERIES AND LANDMARK'TL applied over the required WinterGuard is also recommended. L 90, Landmark shingles have the installer-friendly N'ailTrak"feature, which provides I1/2"wide nailing area and specially formulated ( ,cso•(211t2) Quadra-Bond laminating adhesive(See Figure 12 3). STEEP Sfope Appiubon Landmark Special is impact resistant and is specially over 21l12) manufactured with a reinforced fiberglass scrim to meet UL 2218 Class 4 impact resistance rating. STANDARD SlopNOTE:Landmark Special must be installed over a clean deck(no 4/12 u to 21/12) p (4/t2 up to 2tlf 2) roof-overs)to obtain the UL 2218 rating.It is strongly recommended �18.5'(4112) that impact resistant cap shingles made from RT 30 IR shingles be t.ow installed on all hips and ridges.Some insurance carriers may not SbpeAppfkaSon consider the roof system as compliant to UL 2218 Class 4 without beZ112 z9.5'(2l12) impact resistant cap shingles. Landmark Solaris"shingles are ENERGY STAR*qualified roof Figure 12-1:Slope definitions. products that meet both solar reflectance and thermal emissivity requirements.Using CertainTeed's advanced roofing granules, THE ROOF DECK*MUST BE AT LEAST;3/8"(9.5 mm) Landmark Solaris reflects solar energy and radiates heat far better thick plywood,or 7/16"(11 mm)thick non-veneer,or nominal than traditional roofing shingles—it can reduce the roof's temperature 1" (25 mm)thick wood deck. by as much as 20 percent In the summer,NOTE:Use matching COLD WEATHER CLIMATES (ALL SLOPES):Application of Landmark Solaris hip and ridge shingles which are also solar reflective. WinterGuard or its equivalent is strongly recommended whenever Landmark TL is unique because its patented Tri-Laminate" there is a possibility of Ice build-up.Follow manufacturer's design combines three layers of material to provide a dramatically application instructions, thick shingle with a wood shake style. With the exception of Landmark TL,closed-cut valleys are preferred FLASHING:Corrosion-resistant flashing must be used to help prevent j by CertainTeed when applying these shingles.Open valleys are leaks where a roof meets a wall,another roof,a chimney or other I recommended when applying Landmark TL;however closed-cut objects that penetrate a roof, valleys are also acceptable.Woven valleys are not recommended for SEALING:Shingle sealing may be delayed if shingles are applied Landmark TL because the tri-laminated shingle can buckle and i become damaged when shaped into the valley.Nails are required 1n cool weather and.may be further delayed by airborne dust as fasteners for Landrnarks TL,staples are not allowed, accumulation.If any shingles have not sealed after 2 reasonable i STANDARD OR STEEP SLOPES:CertalnTeed recommends time period,hand seating may be necessary. DiamondDeck"Synthetic Underlayment,Roofers'Select'High CAUTION:To prevent cracking,shingles must be sufficiently warm Performance Underlaymen4 or shingle underlayment tneeling ASTM to allow proper forming for hips,ridges and valleys. t D226,D4869 or D6757.Take care to ensure sufficient deck ventila- i WARRANTY:These shingles are warranted against manufacturing i tlon when DiamondDeck or other synthetic underlayment is installed. defects and are covered by SureStart'protection.See the warranty j Follow manufacturer's application instructions, itself for specific details and limitations. ! LOW SLOPES:One layer of CettainTeed's WinterGuard' Waterproofing Shingle Underlayment(or equivalent,meeting ASTM * For technical questions,information an acceptable D1970)or two layers of 36"wide felt shingle underlayment(Roofers' alternative application methods and materials, =a Select or underlayment product meeting ASTM D226,D4869 or or a copy of the product warranty,contact the 2 11 D6757)lapped 19"must be applied over the entire roof;ensure sources Ilsted below: 3 ,mo sufficient deck ventilation.When DiamondDeck or other synthetic Your suppller or roofing applicator ✓ underlayment is installed,weather--lap at least 20"and ensure CertainTeed Home Institute 800-782.8777 ✓ ✓ sufficient deck ventilation. CertainTeed-RPG Technical Services 800.345.1145 ✓ I ✓ I ✓ 110 FASTENING LOW AND STANDARD SLOPE -.- - — -- -- LANDMARK Shingle - - - _- — 12" 143/4" 12" Roof " —(305 mm)---—(375 mm)—---(305 mm)--{ Deck Prgper Crooked Under- Over- I 1"(25 mm) Release Tape 1"(25 mm)~I - Nailing Driven Driven Nailable'F Figure 12.2:Proper and improper nar(ing. Area 7//, IMPORTANT:For decks 3/4" (19 mm)thick or thicker,nails must go at least 3/4" (19 mm)into the deck.On thinner decks,nails must LANDMARK TL go at least'/s"(3.2 mm) through the deck. 13�12" 13" 13�/2" Nails must be11-or 12-gauge roofing nails,corrosion-resislanl �•-(343 mm)-+�-(330 mmj F y--(343 mm)-�� with at least /8"(9.5 mm)heads,and at least 1" (25 mm)loni;. LandMark TL requires nails at least 11/4"long. I-1"(25 mm) 1"(25 Mm)--►I r: y Nail Area for Low a standard F re 12.4:Usefour nailsforer full shingle.-_-- __ slopes Nail Area for Avoid Placing steepstopes N* ono STEEP SLOPE This Une Release Tape Use six nails and four spots of asphalt roofing cement for every full laminated shingle.See below.Asphalt roofing cement should meet ASTM D 4586 Type 11,Apply 1"spots of asphalt roofing cement under each corner and at about 12"to 13"In from each edge. FRONT LANDMARK Nailing Lines 12" •—_143/4" 12 (305 mm) (375 mm) (305 mm) I BACK _ r 1-1'(25 mm) Release Tape 1"(25 mn)--' I r Nail Area r r Sealant Strips For Steep I (25 mm)1� --- Rz (25 mm) UNDERSIDE Quadra-Bond Roolin Cement l OFTOP l LAMINATE 1 LAYER LANDMARK TL Four laminating adhesive strips for a stronger bond, i3 +-13'/2'------���{ (343 mm) (330 mm) (343 rn t I l l Figure 12-3:)nrlTrak features a wider nail area and �--1"(25mm) extra-strong pnadra Bond construction. I I i 1 I 1 (25 mm) ---- . (25 mm) Addling Cement Figure 12-5-Use six nails and four spots of asphalt roofing cement on steep slopes. CAUTION:Excessive use of roofing cement can cause shingles to blister. CEATAINTEED SHINGLE APPLICATORS MANUAL Cbapler12 111 —— 1ST COURSE:Apply a full shingle at the lower left corner of the TWO CLEAN-DECK APPLICATION METHODS roof.Make the lower edge and left edge lie flush with the edges of the FOR LANDMARK AND starter course(Figure 12-7). LANDMARK TL SHINGLES � 2ND T1iR0UG1!5TH COURSES: FIVE-COURSE DIAGONAL METHOD(6"AND 1 i") CAUTIONI Failure to follow instruction steps 1-5 below will bring FIVE-COURSE DIAGONAL METHOD(55/8"AND 111/4") joints too close together and may cause unattractive patterns! NOTE:The 6"and I V method is shown below.The 55/8"and 111/4" 1.Cut 6"off the left end of the first shingle and save this piece for later method follows the same application instructions as the 6"and 1 t" use.Apply the 323/4"(34"for Landmark TL)long piece over and method except the dimensions of the shingle cut-offs in the second and third courses are 55/8"and 111/4"respectively. above the first-course shingle.Leave the bottom 55/8"tab portion of CAUTION:Use of other installation methods may result in an the first-course shingle exposed. objectionable pattern. 2.Cut 11"off the first shingle of the third course and save this for later.Install the 273/4" (29"for Landmark TL)long piece over and PREPARING THE DECK: above the second-course shingle. • Apply underlayment as required.Certainleed suggests that a 3.Apply the previously removed I I"long piece over and above the layer of shingle underlayment be applied.For UL fire rating, third-course shingle. underlayment is generally required.Apply flat and univrinkled. 4.Apply the previously removed 6"long piece from the second ♦Snap chalklines to assure shingles will be correctly aligned, course over and above the fourth-course shingle. expose all shingles 55/8" (113 mm)• 5.install a full shingle against the right edge of each shingle in STARTER COURSE: courses one through five. 1.Use CertainTeed Swifistart Starter,or three-tab self-sealing shingles CONTINUING UP THE ROOF: with the lower tab portions removed,Be sure that the starter 1.Beginning again with a full shingle,repeat the five-course pattern shingles are at least 75/8"In height.(Figure 12-6). up the left rake.(Figure 12-8,B). 2.Pill-in courses across the roof in a stepped diagonal fashion using full shingles.(Fgure 12-8,A).Do not run courses straight across. Starter Shingle 7 5/8" IMPORTANT:Do not align joints of shingles closer than 31/2" from one another. Reniovelithese p1lortions � Figure 12-G,Make starter shingles that are 75/8"in height. °o�oa 2.For the first starter,cut 6"from one side of the starter shingle. 3.Apply the remaining piece to the lower left corner of the roof. Make sure there is 1/2"overhanging the rakes and eaves if drip edge is being used. If you are not using drip edge,make the a\ overhang 4.Use full length starter shingles for the rest of the course. aft ��y\�GaavR i Figure 12-7:Applying the first S courses of Landmark. Note:?'he Landmark TL dimensions dyer. f 112 Chapter12 CERTAINTBED SHINGLE APPLICATORS MANUAL Figure 12-8.,Nave-Course Dlagona!Method"rnstalkrtion schemalra I For capping hip and ridge,appry CertainTeed I "Accessory"shingles of a h ke color. .t ��ooe��eta VoOeAaiR`¢�� i I I •t I I t t t \ Air Flow I Through Soffit I Provide adequate ventilation under the roof deck to Prevent harmful condensation In winter and heat bulld•up In summer. Line valley by centering IWaterproofing Shingle I i' Underjayrnent or '1 ; I eqoivalent directly I lays deck. 1 I oo � I a°d a�,Oss y aai01,7, /i7P aiiBy i a/ �JipV/ S r I F�ba 'noi/ k, vOVa`\ey����e��`° r9cerne�po/ �O// i Remove I dsbir�9/ef ; i baf5olm Ies 3 calleyrhro nler,,ne Figure 12-9.•highlight of closed•cul vagey details. CERTAINTEED SHINGLE APPLICATORS MANUAL 6'tiapter12 113 CHIMNEY FLASHING NIPS AND RIDGES SHADOW RIDGE"ACCESSORY SHINGLES Metal Step Flashing Shadow Ridge shingles have an accented shadow line that is designed to complement these shingles.Simply fold along the pre-cut lines and 0 mnt � + detach individual cap pieces.Save valuable installation time compared Minimum T (193 mm) 2' 5 7 S/8�� to cutting 3-tab shingles. 3"+(75 mm) 11001, Minimum r• Pigune 12-10.•Step flashing minimum dimensions. Fold.ovin figure 12-12:Shadow Ridge accessory shin;!s detach east y frox counter flashing three pkce units to make 72 individual cap pieces. over step flashing There are 24 three-piece units in each Shadow Ridge bundle, providing 72 Individual caps that will cover 30 linear feet(333/4 linear feet,Metric)of a hip or ridge.Each English dimension cap piece is 12"by 12" (Metric caps are 131/4"by 97/8")and features clipped corners on the bottom edge of the exposed portion. Fasten /�0 Flashing APPLICATION IS AS FOLLOWS: m1;7/ma1,,; To Roof 1.Apply shingles up to the hip or ridge on both sides,then trim Counter f l ~4 flush. i Flashing NOTE:The last course of shingles should have an exposure of 5"(55/8"for metric)or less when the shingle cap or ridge vent is �i fastened in place.Otherwise,a potential water leak could occur at exposed shingle end joints.The figures used in this section illustrate Ao�p�F/ashin9 the application of accessory shingles over a ridge vent;application directly to the roof deck is very similar. 305 Apply Over t Starter Shingle i t I Scarcer Shingle I I I ! I I i �r i Figure 12-1 is Fla>i.riiw around a chimney figure 12-13:Apply a fuU cap sbi ngle over the slarler piece, flush with the bottom and side edges of the starter. 2.Install caps beginning at the bottom of a hip or at either end of a _ ridge.Apply a starter piece that has the bottom 5"(55/8"for i TWO ROOF-OVER METHODS metric)removed(Figure 12-18).Fasten the starter with two nabs FOR LANDMARK AND located about 3"from the rake edge,and 1"In from each side LANDMARK TL SHINGLES edge.Make sore fasteners used to apply caps penetrate at least 3/4"into or through the decking. The same methods used for clean-deck application of these shingles NOTE:To assist in proper alignment when ridge vent is not used, are used for roof-overs.Application of these shingles over English snap a chalk fine parapet to the hip or ridge along the line where dimension shingles is not recommended—due to the highcost of the side edges of the cap shingles should be. workmanship and greater risk of worker error. 114 Cbapter12 CERTAINTEED SHINGLE APPLICATORS MANUAL 3.Apply a full cap shingle over the starter(Figure 12-18),and place 30;V. fasteners at 5/e' (6/4"for metric)up from the exposed bottom r f Laying Notch edge and 1"in from each side.Nails must not be exposed on the finished roof.All nail heads must be driven straight and must not i cut into the shingle surface. SExPuos e l l 6ExFp9 re i I I I n 'I Figure 12-1G•Use laying notches to center shingles on hips and Figure 12-14.-install cap shingles at their correct exposure ridges,and to locate the correct exposure. and cover all fasteners. NOTE:Each cap has a laying/alignmem notch at the top edge to center the piece on the ridge line,and two notches on each side MOUNTAIN RIDGE HIGH-PROFILE to indicate the correct exposure and shadow-line placement HIP AND RIDGE At C E S S O R Y (Figure 12-19).The side notches of the cap being applied should _ be aligned with the top edge of the previously applied cap, Use Mountain Ridge accessory shingles to cover hips,ridges or 12" rake edges.One box will cover 20 linear feet.To prevent damage to (305mm) shingles during application,they must be sufficiently warm to allow 6'------- 6'-- proper forming. (150mm) (150MM) FASTENING i t IMPORTAN'n Use two nails to fasten each shingle.Nails must be Notch for minimurn 13/4"(45 mm)long.For the 4'(100 mm)starter Centering shingle,place fastener 1" (25 mm)in from each side edge and about 12' - 2"00 mm)from the rake(or eave)edge,making sure the fastener (305mm) Notches for Alignment to goes 3/4"into the deck or all the way through.For each full Mountain the Top Edge of the Previous 7" Ridge shingle,place fasteners 8/a (219 mm) up from its exposed Cap for 5"(125mm)Exposure (1 m) bolt edge and 1" (25 mm)in from each side edge. Sealant English Dimension 97/8" i (250mm) •—415/16' ---415/16" Sealant � (125mm )(125mm I I 4"Starter—s lI— 1 Piece Notch for Centering (337mm) Notches for Alignment to 76/8„ the Tops Edge of the Previous (196mm) Figure 12-17-Hip and ridge application. Cap for 5 /8"(141 mm)Exposure Metric Dimension Figure 12-15 r Each Shadow Ridge shingle has a centering notch and two side-alignment notches to help ensure properplacement CERTAINTEED SHINGLE APPLICATORS MANUAL Chapter/2 115 HIP,RIDGE AND RAKE SHINGLE APPLICATION FASTENING Apply the primary field roofing up to the hip or ridge from both IMPORTANT`.Use TWO nails to fasten each shingle.Fasteners must sides of the roof and trim flush or lap over one side,not more than be minimum 1.3/4" (45 mm)long, half the width of a Mountain Ridge shingle. Por the starter shingle,place fastener 1"in from each side edge and Assure that the installed Mountain Ridge shingles properly cover about 2"up from the starter shingle's exposed butt edge,making hip and ridge field shingles on both sides and the field shingles sure fastener goes 3/4"into the deck or all the way through the deck. applied along rake edges.For a rake edge installation,cut the field (see Figure 12-19).For each full Cedar Crest shingle,place fasteners shingles flush to the rake edge.Apply Mountain Ridge shingles 8-5/8"up from its exposed butt edge and 1"in from each side edge ensuring they fit securely against the rake board.To assist in (see Figure 12-20). proper alignment,snap a chalk line parallel to the hip, ridge or rake along the line where the side edges of the 12, Mountain Ridge shingles should fall. !�- sp ro�Nrglo Prepare a 4"Starter shingle by cutting off the lower 8"color granule butt portion of one Mountain Ridge shingle,Apply the 4" starter piece(with sealant nearest the outer edge)over the bottom ; corner of the hip or rake,or on either end of the ridge,overhanging the corner or end by approximately 1/2"and bending the starter shingle along its centerline to form into place(see figures below.) Install a nail on each side about 2"up from the starter shingle's exposed butt edge and I"in from each side edge of the shingle.The 7,pmm\ 8"piece that was cut off may be used to finish the opposite end of hip,ridge or rake. Next,apply a full Mountain Ridge shingle over the installed starter shingle,bending it along Its centerline and forming Into place over the hip,ridge or rake,flush with the bottom and side edges of the starter shingle.Install a nail on each side of the shingle 85/4"up from the bottom edge and l"in from each side edge. Figure 12-19:Apply a full cap shingle over the starter shingle. Continue application of the Mountain Ridge shingles along the hip, ridge or rake as shown.Expose Mountain Ridge shingles 8",covering !, all fasteners. i I� CEDAR CREST MEDIUM-PROFILE ! 05�t� HIP AND RIDGE ACCESSORY SHINGLES Use Cedar Crest accessory shingles to cover hips and ridges. Carefully separate the three-piece units prior to application,by first folding along the pre-cut fines and then detatching the pieces j see Figure/2-18).No cutting is necessary.There are 30 individual i shingles(I0 three-piece units)in each bundle.One bundle will cover 20 linear feet.Each I2"x 12"shingle has'a shadowline that is a design feature which is visible when applied properly.To prevent shingle damage during application,they must be sufficiently warm to ! allow-roped rnl;q Three-piece unit Figure 12-20.•Install cap shingles at an 8"exposure e and faslen with one nail on each side as shown. j I 1 1 ShadoMine I 2 3 Figure 12-18:Separate to make3 cap shingles. I 116 Chapter12 CERTAINTEED SHINGLE APPLICATORS MANUAL IMPORTANT,High Wind Instructions. In order to achieve the CEDAR CREST APPLICATION ASTM D3161 Class'F"Wind Resistance Classification each"hip and ridge"shingle must be both 1)fastened with nails as shown and 2) Apply primary roofing up to hip or ridge on both sides of roof and hand-sealed with two 1/4"wide beads of either BASF"Sonolasfic' trim flush.Ensure that the Cedar Crest shingles will adequately cover NPI'Adhesive"or Henkel"PLO Polyurethane Roof&Flashing Cement" the top course of the shingles on both sides of the hip or ridge. applied from the middle of the shingle's raised overlay on the top piece Prepare a 4""starter"shingle by cutting off the lower 8"color gran- and extending approximately aOheaNp ule portion of one Cedar Crest shingle.Apply the 4"starter piece with Hur,daoafiaa 4" along the sides of the �` raised overlay edge over the bottom corner of the hip or to either end headlap along a line 3/4"-1" of the ridge,overhanging the corner or end by approximately 1/2" in from each side edge of the 1/4- `--- 4' and bending the starter shingle along Its centerline to form into place shingle's headlap as shown. (see Figure 12-19),Install a nail on each side about 2"up from the Immediately align and apply 374' .Y �'— starter shingle's exposed butt edge and I"In from each side edge of the next overlying shingle, the shingle. gently pressing tab sides into _ �. Then apply a full 12"x 12"piece over the starter,bending the shingle adhesive.Only one side of Dab ofasphalt i along its centerline and forming it into nlace over the hit)or ridge, the double thickness lab is �Shinaatay� flush with the bottom and side edges of the starter shingle,Fasten laminated together;to secure Pigrrre 12.21:11aad seal caps with two nails minimum 1-3/4"long with one nail on each side of the other side,;after folding rc�,l,,,vn shingle 8 5/8"up from the butt edge and I"in from each side edge the shins;c over die ridge and (see Figure 12-20). nailing into position,a i"diameter spot of either NPl or PL adhesive Continue application of Cedar Crest shingles up the hip or along must be applied between the shingle layers as shown.immediately align the ridge,forming each shingle over the hip or ridge,and fasten as and apply the next overlying shingle,gently pressing tab sides into shown in Fastening.Expose Cedar Crest shingles 8",covering all adhesive. fasteners. To assist in proper alignment,snap a chalk line parallel to the hip or ridge applying along the line where the side edges of the Cedar Crest shingles should be. M i i i f i I #i I 1 Here's a Tap...In the winter put hip and ridge cap shingles in your truck with the beater blasting for 20 minutes so the caps don't crack when formed. (Thanks to Mark Dulz,Ricbmond,MI) CERTAINTEED SHINGLE APPLICATORS MANUAL Cbapler12 117 f BUILDING INSPECTION REPORT — Commercial Final Permit No. 20120117 Address: 8110 207th St. NE Contractor: Legends Roofing Owner: Arlington School District Date: 8/28/2013 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER INSPECTION: Re-roof of existing school facility UL CLASS A: FX ICC-ES-ESR-1389: INSTALLED PER PLAN: FINAL: Date: 8/28/2013 Permit#: 117 Permit Date: 06/13/13 Permit Type: COMMERCIAL RE-ROOF Project Name: Kent Prairie Elementary Applicant Name: Applicant Address: Applicant, City, State, Zip: Contact: Phone: Email: Scope of Work: School ReRoof Valuation: 385080.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/19/2013 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31051100400600 8110 207TH ST NE ARLINGTON SCHL 681 Nursery,Primary DIST 16 &Secondary School Contractors Contractor Primary Contact Phone Address Contractor Type License License# Legends Roofing Co, Ron McCullah 253-606-9070 PO Box 371249 CONSTRUCTION Labor&LEGENRC984DN Inc CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 06/13/2013 BLD Ok to issue z.Christopher Young 06/13/2013 BLD Permit Tracking Fees Fee Description Notes Amount Building Pen-nit Table 4-1 $3,390.78 Total $3,390.78 Attached Letters Date Letter Description 06/14/2013 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount Kent Prairie 06/19/2013 Timothy W.O'Brien Elementary Re-Roof Credit#5360 $3,390.78 Permit-8110 207th St Outstanding Balance $0.00 Uploaded Files Date File Name 08/28/2013 8110 207TH sT.docx 06/13/2013 Kent Prairie ReRoofpdf