Loading...
HomeMy WebLinkAbout410 S Macleod Ave_BLD4314_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 410 S MACLEOD AVE Permit#:4314 Parcel#;004]1700700700 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Furnace Replacement Valuation: .00 OWNER APPLICANT CONTRACTOR CORTER MITCHELL T&ANDREA M CPI Plumbing CPI PLUMBING&HEATING 410 S MCLEOD AVE 1900 Railroad Ave 1900 Railroad Ave ARLINGTON,WA 98223 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360-868-6399 360-428-5636 LIC:CPTPLPH950MN EXP:07/15/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CPI PLUMBING&HEATING 1900 Railroad Ave Mount Vernon,WA 98273 360428-5636 LIC#:CPIPLPH85OMN EXP: 07/15/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES; CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND AP PR-OVAL 0LACERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. S S T: .' `E•Salting to construction and construction materials in the City of Arlington must be reported on your sal-tax rehmi form ani�rflrlington#3101. 12/1512021 Signature Print i . to Dat Released By Date u I CONDITIONS Adhere to approved appliances.Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 12/16/2021 Processing/Technology $25.00 12/16/2021 Inspection $75.00 12/16/2021 Forced Air Heat $15.00 12/16/2021 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I I 1 RESIDENTIAL MECHANICAL y ? PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:410 South Mcleoud Ave, Arlington WA 98223 Project Description:Furnace Replacement Owner: Laurie Lowe Address: 140 South Mcleoud Ave City: Arlington State:Wa Zip Code: 98223 Phone: 425-327-3455 Email:lauriew914@ gmail.com Applicant: Sydnee Butler Address: 1900 Railroad Ave City: Mount Vernon State Zip Code: 98273 Phone: 360-868-6399 Email: permitting@ cpiplumbing.com CONTRACTOR INFORMATION Contractor Name:CPI Plumbing & Heating Address: 1900 railroad Ave City: Mount Vernon Stated Zip Code: 98273 License Number:CPIPLPH791NB Expiration: 7/20/21 Phone:360-868-6399 Email:permitting@ cpiplumbing.com ,P,,IV STAFF USE ONLY DEC 15 2021 Permit #: Accepted by: Date: 6/16LP Page 1 of 2 A , RESIDENTIAL MECHANICAL PERMIT APPLICATION IAl,fN ,O Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES S9V2B060D3VSA6 60K (BTUH) � Furnace (80+) Model # _ AFUE Heat Pump Model # AFUE HSPE_ ❑ AC Unit Model # SEER Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping Cl Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances M 1�'��i�r� eee� �������,�••�' 12/15/2021 Applicant Signature: Date: Applicant Printed Name: Sydnee Butler I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Submittal Dedicated Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTU H Downflow Only S9V2B060D3PSBC Note:Graphics in this document are for representation only.Actual model may differ in appearance. ,June 2021 S9V2B060D3-SUB-2A-EN Outline Drawings a LI A � x a z - - i V - C x s_ +r � 4J LL III1L� {III 1 1 1 O V 3 , N om 7 a cc - S s^ 2 S9V2BO6OD3-SUB-2A-EN Product Specification Model S9V2BO6OD3PSBC Model S9V2BO6OD3PSBC (a),(b) (a),(b) Type Downflow INLET AIR DIAMETER-MIN. 2 Round RATINGS W (in.)(e) 1st Stage Input BTUH 39,000 HEAT EXCHANGER—Type Fired 409 Stainless Steel 1st Stage Capacity BTUH(ICS) 37,700 — Unfired 29-4C Stainless Steel 2nd Stage Input BTUH 60,000 Gauge(Fired) 20 2nd Stage Capacity BTUH(ICS)(d) 57,850 ORIFICES-Main 1st Stage Temp.Rise(Min.-Max.)IF 25-55 Nat.Gas(Qty.-Drill Size) 3-45 2nd Stage Temp.Rise(Min.-Max.)IF 35-65 Propane Gas(Qty.-Drill Size) 3-56 AFUE(%)(d) 96.0 GAS VALVE Redundant-Two Stage Return Air Temp.(Min.-Max.) IF 45OF-80°F PILOT SAFETY DEVICE BLOWER DRIVE DIRECT Type 120 V SiNi Igniter Diameter-Width(in.) 11 X 8 BURNERS-TYPE-QTY Inshot-3 No.Used 1 POWER CONN.-V/Ph/HZ M 120/1/60 Speeds(No.) Variable Ampacity(Amps) 7.9 CFM vs.in.w.g, See Fan Performance Table Max.Overcurrent Protection(Amps) 15 Motor HP 1/2 PIPE CONN.SIZE(IN.) 1/2 R.P.M. Variable DIMENSIONS H x W x D Volts/Ph/Hz 120/1/60 Uncrated(in.) 34 x 17-1/2 x 28-3/4 FLA 5.7 Crated(in.) 35-1/2 x 19-1/2 x 30-7/8 COMBUSTION FAN-Type PSC WEIGHT Drive-No.Speeds Direct-2 Shipping(Lbs.)/Net(Lbs.) 127/119 Motor RPM 3300/2600 (a) Meets Energy Star (b) Central Furnace heating designs are certified to ANSI Z21.47/CSA Volts/Ph/Hz 120/1/60 2.3-latest edition. FLA 0.66 (c) For U.S.Applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above Inducer Orifice 0.79 sea level.For Canadian applications,above input ratings(BTUH)are FILTER-Furnished? No up to 4,500 feet,derate 49/6 per 1,000 feet for elevations above 4,500 feet above sea level. Type Recommended High Velocity (d) Based on U.S.government standard tests. (e) Referto Vent Length Table in the Installer's Guide. Hi Vel.(No.-Size-Thk.) 1-16 X 25-1 in. M The above wiring specifications are in accordance with National VENT OUTLET DIAMETER-MIN. Electrical Code;however,installations must comply with local codes. (in.)(e) 2 Round S9V2BO6OD3-SUB-2A-EN 3 Heating and Cooling Airflow Tables Table 1. S9V2B060D3PSBC Heating Airflow S9V2B060D3PSBC Furnace Heating Airflow(CFM),Temp.Rise(OF),and Power(Watts)vs.External Static Pressure with Filter(iwc) 1st Stage Capacity=37,830 2nd Stage Capacity=58,200 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 677 677 678 678 678 Low 711 Temp.Rise 52 52 52 52 52 Watts 49 94 139 184 229 CFM 787 775 763 751 739 Medium Low 814 Temp.Rise 45 46 47 48 49 (a) Heating 1st Watts 71 116 160 205 249 Stage CFM 865 856 846 837 827 Medium 893 Temp.Rise 41 41 42 42 43 Watts 86 134 182 230 278 CFM 1033 1013 994 974 955 High 1067 Temp,Rise 35 35 36 36 37 Watts 141 193 245 297 349 CFM 859 856 853 850 847 Low 900 Temp.Rise 63 63 63 63 63 Watts 1 90 139 188 237 287 CFM 977 967 958 948 938 Medium Low(a) 1030 Temp.Rise 55 56 57 57 58 Heating 2nd Watts 126 179 232 285 338 Stage CFM 1067 1053 1040 1027 1013 Medium 1130 Temp.Rise 51 52 52 53 54 Watts 162 219 275 332 388 CFM 1 1246 1234 1222 1209 1197 High 1350 Temp.Rise 44 1 44 1 44 45 45 Watts 279 333 387 440 494 (a) Factory Setting. 4 S9V2BO6OD3-SUB-2A-EN Heating and Cooling Airflow Tables Table 2. S9V2B060D3PSBC Cooling Airflow S9V2B060D3PSBC Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Cooling Unit Airflow External Static Pressure Setting 0.1 0.3 0.5 0.7 0.9 Outdoor (CFM/ton) Cooling 450 CFM 672 674 672 666 656 CFM/Ton Watts 48 84 122 161 203 Cooling 420 CFM 626 628 627 622 612 CFM/Ton Watts 41 76 112 150 190 Cooling 400 CFM 595 598 597 592 583 CFM/Ton Watts 37 70 105 143 182 Cooling 370 CFM 549 553 552 547 538 CFM/Ton Watts 32 63 97 133 171 Cooling 1.5 Tan Cooling 350 CFM 518 522 522 518 509 CFM/Ton Watts 29 59 91 126 164 Cooling 330 CFM 487 492 492 488 479 CFM/Ton Watts 26 55 86 121 158 Cooling 310 CFM 456 461 462 458 449 CFM/Ton Watts 23 51 81 115 153 Cooling 290 CFM 425 431 432 428 420 CFM/Ton Watts 21 47 77 111 148 Cooling 450 CFM 894 891 882 871 873 CFM/Ton Watts 91 137 182 228 282 Cooling 420 CFM 838 839 835 827 816 CFM/Ton Watts 78 122 166 212 259 Cooling 400 CFM 798 799 795 788 778 CFM/Ton Watts 70 112 155 199 244 Cooling 370 CFM 737 739 736 730 719 CFM/Ton Watts 58 98 138 180 223 Cooling 2.0 Ton Cooling 350 CFM 697 699 697 690 680 CFM/Ton Watts 52 89 128 168 211 Cooling 330 CFM 656 659 657 651 641 CFM/Ton Watts 46 81 118 157 199 Cooling 310 CFM 616 618 617 612 602 CFM/Ton Watts 40 74 110 147 187 Cooling 290 CFM 575 578 577 572 563 CFM/Ton Watts 35 67 101 138 177 Cooling 450 CFM 1120 1117 1111 1102 1089 CFM/Ton Watts 162 218 275 332 390 Cooling 420 CFM 1037 1035 1029 1020 1008 CFM/Tan Watts 132 185 238 291 346 Cooling 400 CFM 997 996 991 982 970 CFM/Ton Watts 120 171 222 274 327 Cooling 370 CFM 923 1 923 918 910 898 CFM/Ton Watts 99 146 194 243 293 Cooling 2.5 Ton Cooling 350 CFM 873 873 869 861 850 CFM/Ton Watts 86 132 177 224 273 Cooling 330 CFM 823 824 820 813 802 CFM/Ton Watts 75 118 1 162 207 253 Cooling 310 CFM 773 774 771 764 754 CFM/Ton Watts 65 106 147 191 235 Cooling 290 CFM 722 724 721 715 705 CFM/Ton Watts 56 94 134 175 218 Cooling 450 CFM 1336 1332 1324 1313 1299 CFM/Ton Watts 263 329 395 462 529 Cooling 420 CFM 1250 1247 1239 1229 1216 CFM/Ton Watts 218 280 343 406 470 Cooling 400 CFM 1193 1189 1183 1173 1159 CFM/Ton Watts 191 251 311 372 433 Cooling 370 CFM 1105 1103 1097 1087 1075 Cooling 3.0 Ton(a) CFM/Ton Watts 156 212 268 325 382 Cooling 350 CFM 1046 1045 1039 1030 1018 CFM/Ton(a) Watts 135 189 242 296 351 Cooling 330 CFM 987 986 981 973 961 CFM/Ton Watts 117 167 218 270 322 Cooling 310 CFM 928 927 923 915 903 CFM/Ton Watts 100 148 196 245 295 Cooling 290 1 CFM 868 i 868 864 1 857 845 CFM/Ton Watts 85 1 130 176 1 223 271 (a) Factory Setting S9V2B060 D3-SUB-2A-E N 5 General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the Furnace is certified by the manufacturer to leak 1%or American Gas Association for both natural and L.P. less of nominal air conditioning CFM delivered when gas. Limit setting and rating data were established and pressurized to.5"water column with all inlets,outlets, approved under standard rating conditions using and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. QUICK HEATING The S-Series furnace has a special type 29-4CT"^stainless steel secondary heat exchanger to reclaim Durable,cycle tested, heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and Heavy gauge steel and "wrap-around"cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside. enamel finish for strength and beauty.Every BURNERS orientation has at least two venting options.There are no knockouts on cabinet. Multiport Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot INTEGRATED SYSTEM CONTROL Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat.Complete front service access. valve,flame control and includes self diagnostics for a. Low energy power venter ease of service.Also contains dry contacts for EAC and HUM. b.Vent proving pressure switches. 6 S9V2BO60D3-SUB-2A-EN Features and Benefits 96.0%AFUE ACROSS ALL MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections;no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Works great with larger,high-efficiency coils Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3—WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 6 SKU's — Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 5 SKU's — Downflow VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in. H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CFM/ton Blower deck has full-length rails for easy removal and REGULATORY replacement,regardless of poise All models are airtight; 1%or less air leakage as per THREE—WAY MULTI-POISE (UPFLOW, ASHRAE 193 HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED Open vestibule design provides a full 34" high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install(no kits required) Width is industry standard: 17.5" Every model has at least two venting options Depth remains approximately 28" When in horizontal,trap extends only about 2" Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as,other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup/Status/Diagnostics/Digital Display Vent table improvements including longer vent No dip switches lengths;2" pipe can be used up to 100K S9V26060D3-SUB-2A-EN 7 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable,energy efficient indoor environments for residential applications.For more information,please visit www.trane.com or www.americanstandardair.com. Fm,d"mmw,., c Om us Intertek The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. S9V2BO6OD3-SUB-2A-EN 15Jun2021 Supersedes(New) 02021 Permit#: 4314 Permit Date: 12/15/21 Permit Type: RESIDENTIAL MECHANICAL Project Name: Lowe Applicant Name: CPI Plumbing Applicant Address: 1900 Railroad Ave Applicant, City, State, Zip: Mount Vernon,WA 98273 Contact: Sydnee Butler Phone: 360-868-6399 Email: permitting@cpiplumbing.com Scope of Work: Furnace Replacement Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 06/13/2022 Form Permit Type: Status: COMPLETE Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CORTER 100 SINGLE 00411700700700 410 S MACLEOD AVE MITCHELL T& FAMILY ANDREA M RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CPI PLUMBING& 360-428-5636 1900 Railroad Ave CONSTRUCTION COA 604909749 HEATING CONTRACTOR CPI PLUMBING& 360-428-5636 1900 Railroad Ave CONSTRUCTION Labor&Industries CPIPLPH780M1 HEATING CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status O1/19/2022 R00.FURNACE O1/20/2022 01/20/2022 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 12/15/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 12/17/2021 Sydnee Butler 90317500 $140.00 12/17/2021 90317500 Ameresia Lawlis $4.20 Outstanding Balance $0.00 Uploaded Files Date File Name 12/20/2021 10335474-4314 Signed Permit.pdf 12/15/2021 10313480-4314 Specs.pdf 12/15/2021 10313481-4314 Application.pdf