Loading...
HomeMy WebLinkAbout7225 Harrow Pl_BLD4254_2026 CITY OF ARLINGTON �• 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Pen-nit Center: 360-403-3551 BUILDING PERMIT 7225 HARROW PL Permit#:4254 Parcel#:00898300004500 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Like in kind fiirnace Valuation:.00 OWNER APPLICANT CONTRACTOR POSEY WENDELL&LENORE Nordstrom Heating and Air NORDSTROM HEATING&AIR INC PO BOX 926 1059 State Ave Suite G 1059 State Ave. Ste.G LAKE STEVENS,WA 98258 Marysville,WA 98270 MARYSVILLE,WA 98270 3604740919 3603869819 425-335-4029 LIC:NORDSHA884JW EXP:04/16/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR NORDSTROM HEATING&AIR INC 1059 State Ave.Ste.G MARYSVILLE,WA 98270 425-335-4029 LIC#: NORDSHA884JW EXP: 04/16/2022 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of structure where in violation of this Code,any other City ordinances of this ,jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE,LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. ,SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. V W I Y� 1 ��`��,( Q ll lrt .A/�i� 11/18/2021 Si i alure Print Nai e Date Released By Date CONDITIONS Adhere to approved appliances.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/18/2021 Inspection Fee 11/18/2021 Forced Air Heat $75.00 11/18/2021 Mechanical Base $15.00 11/18/2021 Processing/Technology Fee $25.00 $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RESIDENTIAL MECHANICAL PERMIT APPLICATION �� O LIN Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551N AND THIS APPLICATION IS TO BE USED WHEN APPLYING FOR OUT MECHANICAL PAGES OF THIS INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILLTION AND INCLUDE ALL INFORMATION. Project AddreSs:7225 Harrow PI. Arlington, WA 98223 Project Description: like in kind furnace Lenore Posey Owner: Arlington State WA Zip Code: 98223 Address: 7225 Harrow PI. City: Pposey.family@comcast.net hone: 360-474-0919 Email: Applicant: Nordstrom Heating and Air WA 98270 Address: City: 1059 State AVE Suite G Marysville State. Zip Code: - office@ nordstromheating.com Phone: 360-386-9819 Email: CONTRACTOR INFORMATION Nordstrom Heating and Air Contractor Name: Marysville State�NA Zip Code: 98270 Address: 1059 State AVE Suite G City: License Number:nordsha884jw Expiration: 04-16-2022 Phone:360-386-9819 Email:office@ nordstrom heating.com r� STAFF USE ONLY NOV 1 7 zoz� Permit #: ' u2� Accepted by: CS%.�- Date: 6/16LP Page 1 of 2 • RESIDENTIAL MECHANICAL PERMIT APPLICATION Clty of Arlingto�nep 204 59 h A e NE �q�i�& IoCO�°���development 9 3 • Phone(360j 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model#TUD2C100ACV52B - - -- - - AFUE80% ❑ Heat Pump Model #_ - - - - AFUE_ HSPE ❑ AC Unit Model#-- - - - - - - - SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance Other Gas Plping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be su • Proper Combustion air and ventin g for all applian es every to 8 eet • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date, 11/16/2021 Applicant Printed Name: Jessica L Schuerman I hereby certify that the above information is correct_and that the construction, install aon for Property will be in accordance with the applicable laws of the City of Arlington and the State of Washing o mentioned 6/16LP Page 2 of 2 R� 17' Wd Dk — , 198 s.f. b R 23' 1 iq 1 1sFr 1558 s.f. �p 1 1 -v 10' T* 6' 11' N) it � 8, s 8• o Fr G RFX 482 s.f. Co Ole 24 97 21' 17, Cone 26' ap 198 s.f. 23' 1 B-woFln 1� r 1. 10' 17' Zv� al�'c s TUD213100ACV-SUB-1 E TAG: TUD213100ACV3213 Communicating or 24V AUD2B080ACV32B non-communicating Upflow/Horizontal Left Direct/Non-Direct Vent 2 Stage Gas Furnace with Variable Speed Inducer 5/8" 16-1/4�� .� 5/8" - 28-3/8" .� 19-5(8" 1/2" 4"DIAMETER FLUE CONNECT 7/8"DIA.HOLES ELECTRICAL �9-5/8" CONNECTION 4-1/16" D 1/2" K' D 3/4" � O�� D � t "H 3-15/16" D D D 2-1/16 ��/s OLE WITH PLUG \ D � ELECTRICAL CONNECTION /16" `8-1/4" (ALTERNATE) 40" _0 3-3/4" 3/4" ' ' I 2-1/16" 1 _ 01-5/8"HOLE ;0 I WITH PLUG(2) 28-1/4" 3/4" ` j 1 28-1/4" / 5-5/16" 3-13/16" I � 1-1/2"DIA. HOLE �► 3/8" GAS CONNECTION 1-1 2-1/8" ©2016 Ingersoll Rand *UD2B100ACV Airflow- Heating *UD26100ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 842 848 841 828 812 839 TEMP RISE 57 57 57 58 59 WATTS 79 178 188 204 236 HEATING CFM 907 912 906 893 875 1ST 904 TEMP RISE 53 53 53 54 55 STAGE WATTS 97 207 217 231 262 CFM 973 976 971 958 939 969 TEMP RISE 49 49 49 50 51 WATTS 118 240 249 261 291 CFM 1298 1295 1293 1278 1253 1290 TEMP RISE 57 57 57 58 59 WATTS 258 451 456 452 459 HEATING CFM 1399 1394 1393 1378 1351 2ND 1390 TEMP RISE 53 53 53 54 55 STAGE WATTS 315 533 537 527 521 CFM 1500 1493 1493 1478 1448 1490 TEMP RISE 49 49 49 50 51 WATTS 378 623 627 608 588 *UD2B100ACV Airflow-Cooling *UD213100ACV3213 Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 424 442 438 424 412 WATTS 25 53 78 102 127 350 CFM 514 533 526 512 493 1.5 WATTS 33 65 91 118 143 400 CFM 603 615 606 592 576 WATTS 44 79 107 135 164 450 CFM 686 691 676 667 652 WATTS 65 95 125 154 186 290 CFM 575 588 582 569 552 WATTS 40 75 101 130 158 350 CFM 712 716 703 691 677 2.0 WATTS 70 101 130 159 193 400 CFM 801 806 800 783 772 WATTS 84 227 160 192 227 450 CFM 908 910 905 895 879 WATTS 112 161 197 232 267 290 CFM 732 738 729 716 700 WATTS 67 007 136 168 200 350 CFM 884 884 880 867 851 2.5 WATTS 104 151 186 220 256 400 CFM 999 1004 1001 990 978 WATTS 146 199 239 279 318 450 CFM 1132 1134 1131 1123 1114 WATTS 204 262 310 354 399 290 CFM 878 882 875 859 844 WATTS 104 550 185 220 254 350 CFM 1055 1057 1054 1042 1036 30 WATTS 178 224 266 307 350 400 CFM 1205 1202 1200 1195 1190 WATTS 239 305 353 402 451 450 CFM 1351 1354 1351 1323 1253 WATTS 337 409 1 469 503 500 NOTES: 1. *FIRST LETTER MAY BE"A"OR'T' 2. —FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4.WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS 4JNQ0I`AfQA1r RPle, HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. Airflow Adjustment Check inlet and outlet air temperatures to make sure they are within the range specified on the Furnace rat- PRODUCT SPECIFICATIONS n ing nameplate. If the airflow needs to be increased or MODEL 'UD28100ACV328 decreased, see the Airflow Label on the Furnace or the E Upflow/Horizontal unit's Service Facts for information on changing the speed AT N s 7 of the Blower Motor for your specific model.Blower speed 1st Stage Input BTUH 65,000 changes are made on the User Interface. 1st Stage Capacity BTUH(ICS) O 52,000 2nd Stage Input BTUH 100,000 2nd Stage Capacity BTUH(ICS) O 80,000 INDOOR BLOWER TIMING Temp,rise(Min.-Max.)°F 40-7o Heating: The Integrated Furnace Control module con- D WER DRIVE i Direct trols the Indoor Blower. The Blower start is fixed at 45 Dameter Width(In.)No.used 10 x 7 seconds after ignition. The FAN-OFF period is field se- 1 CFM vs.in.lectable by the User Interface at 60, 100, 140,or 180 sec- Speeds( .w Variable onds.The factory setting is 100 seconds. .g.Motor HP See Airflow Table R.P.M. 1/2 Volts/Ph/Hz Variable FLA 115/1/60 COMBUSTI N FAN—Type 5.2 Centrifugal Drive-No.Speeds Direct-2 Motor HP-RPM 1/75.2708/1868 Volts/Ph/Hz 115/1/60 FLA FILTER— urntsled? 0.87/0.49 Type Recommended Yes High Velocity Hi Vol.(No,-Size-Thk.) 1-17x25.1 in. V — Ze(In, 4 Round HEAT EX HANG Type-Fired Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 R ICE —Main -- Nat.Gas.Qty.—Drill Size 5—45 L.P.Gas Qty.—Drill Size 5—56 AS V L E Redundant-Two Stage PIL A T D E Type Hot Surface Ignition B NERS—Type Multi-part In-shot Number 5 P WER CONIC— Ph Z a 115/1/60 Ampacity(In Amps) 8.1 Max.Overcurrent Protection(Amps) 15 PIPE 0 ZE In. 1/2 -- Crated(In.) HxWxD WEIGHT 41-3/4 x 19-1/2 x 30.1/2 Shipping(Lbs.)/Net(Lbs.) 148/138 May be'T'or'A' Central Furnace heating designs are certified to ANSI 721.47/CSA 2.3 ,0 For U.S.applications,above Input ratings(BTUH)are up to 2,00o feet,derate 4%per 1.000 foot for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feel,aerate 4„' Per 1.000 feet for elevations above 4,50o feel above sea level. OO Based on U.S.government standard tests. O The above wiring specifications are in accordance with National Electrical Code;however, Installations must comply with local codes. O Furnace ships in natural gas configuration. The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. OO First stage output capacity is approximately equal to 65%of second stage capacity. 0 Direct drive variable speed blower motor is an ECM constant aidlow,blower motor, Mechanical Specifications COMMUNICATING MODE QUICK HEATING ENERGY EFFICIENT OPERATION Furnace is shipped ready to be con- Durable, cycle tested, heavy gauge alu- Furnace is certified to leak 2%or less of nested in communicating mode using minized steel heat exchanger quickly nominal air conditioning CFM delivered three wire honk-(ip using T/ACONT900 transfers heat to provide warm condi- when pressurized to.5"water column comfort control. tioned air to the structure. Low energy with all inlets,outlets,and drains sealed. ALTERNATE 24V MODE power vent blower,to increase ef- STYLING Furnace is field configurable to 24V non- ficiency and provide a positive discharge Heavy gauge steel and"wrap-around" communicating mode. of gas fumes to the outside. cabinet construction is used in the COMFORT CONTROL BURNERS cabinet with baked-on enamel finish for Communicating furnace design, offers Multfport In-shot burners will give years strength and beauty. The heat exchanger plug and play— walk away installation. of quiet and efficient service. All models section of the cabinet is completely lined Assures the entire heating and air con- can be converted to L.P.gas. with foil faced fiberglass insulation. This ditioning system is set up in the proper INTEGRATED SYSTEM CONTROL results in quiet and efficient operation modes to optimize the engineered Exclusively designed operational pro- due to the excellent acoustical and insulating qualities of fiberglass. Built-in gram provides total control of furnace performance of the matched system installed. limit sensors, blowers, gas valve,flame bottom pan and alternate bottom, left or control and includes self diagnostics for right side return air connection provision. NATURAL GAS MODELS ease of service. Also includes connec- Central Heating furnace designs are e points for E.A.C./humidifier. FEATURES AND GENERAL OPERATION certified to ANSI Z21.47/CSA 2.3 for . . The High Efficiency Gas Furnace both natural and L.P.gas. Limit setting AIR DELIVERY employs a Hot Surface Ignition system, and rating data were established and The variable speed,direct drive blower which eliminates the waste of a constant approved under standard rating condi- motor,has sufficient airflow for most burning pilot, The integrated system tions using American National Standards heating and cooling requirements,will control lights the main burners upon Institute standards. switch from heating to cooling speeds a demand for heat from the room thermo- SAFE OPERATION on demand from room thermostat. The stat. Complete front service access. The Integrated System Control has solid blower door safety switch will prevent or a. Low energy power venter state devices,which continuously monitor terminate furnace operation when the b. Vent proving pressure switch. for presence of flame,when the system blower door is removed. is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. Ingersoll Rand has a policy of continuous product and U6 product data improvement and it reserves the right to "^LO change specifications and design without notice. Intertek _Publication Number TUD26100ACV-SUB-1E Ingersoll Rand Supersedes TUD213100ACV-SUB-113I 6200 Troup Highway Date 12/16 Tyler,TX 7571 1-901 0 Since the manufacturer has a policy of continuous product and product data improve- ment it reserves the right to change design and specifications without notice. I I �� .� Permit#: 4254 Permit Date: 11/18/21 Permit Type: RESIDENTIAL MECHANICAL Project Name: Posey Applicant Name: Nordstrom Heating and Air Applicant Address: 1059 State Ave Suite G Applicant, City, State, Zip: Marysville,WA 98270 Contact: Phone: 3603869819 Email: office@nordstromheating.com Scope of Work: Like in kind furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 05/17/2022 Form Permit Type: Status: COMPLETE Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning POSEY WENDELL 100 SINGLE 00898300004500 7225 HARROW PL &LENORE 3604740919 FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# NORDSTROM 1059 State Ave. CONSTRUCTION HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR COA 601764617 NORDSTROM 1059 State Ave. CONSTRUCTION Labor&NORDSHA772L2 HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 01/05/2022 R04.PLUMBING 01/06/2022 01/06/2022 BUILDING Approved GROUNDWORK Fees Fee Description Notes Amount Inspection $75.00 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 11/18/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/18/2021 Daniel Nordstrom 89821113 $140.00 11/18/2021 Ameresia Lawlis $4.20 Outstanding Balance $0.00 Uploaded Files Date File Name 11/19/2021 10142125-scan-082834 POSEY.pdf 11/18/2021 10132026-4254 Attachment.pdf 11/18/2021 10132027-4254 Application.pdf