Loading...
HomeMy WebLinkAbout17222 43rd Ave Ne_BLD4193_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17222 43RD AVE NE Permit#:4193 PERMIT EXPIRES 180 DAYS AFTER Parcel#:31052100304300 DATE OF ISSUANCE. Scope of Work:Install IP Fire Communicator Valuation:900.00 OWNER APPLICANT CONTRACTOR CORP OF PRESIDING BISHOP OF Security Solutions NW SECURITY SOLUTIONS NW LDS 50 E NORTH TEMPLE ST 22ND 1619 N State St 1619 N STATE STREET FLOOR SALT LAKE CITY,UT 84150-3620 Bellingham WA 98225 BELLINGHAM,WA 98226 360-734-4940 360.734.4940 LIC:SECURSN954JG EXP:04/07/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR SECURITY SOLUTIONS NW 1619 N STATE STREET BELLINGHAM,WA 98226 360.734.4940 LIC#:SECURSN954JG EXP: 04/07/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCl10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City or Arlington#3 101. DOCUSIgn�eed by: VAYC� ljbf VSwtA Darcy Boersma 10/19/2021 / l Signature Print Name Date Released By Date CONDITIONS 1.Permit and set of approved plans to remain on site during installation_Installers shall present NICET II certification upon request.2.Trouble condition to be verified for signaling circuits.3. Signal transmission to Central Station Monitoring Company to be verified.4.Installation completion form shall be submitted to The Compliance Engine prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC_)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/18/2021 Fire Alarm System Permit $75.00 10/18/2021 Processing/Technology Fee $25.00 10/18/2021 Fire System Plan Review $100.00 Total Due: $200.00 Total Payment: $0.00 Balance Due: $200.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon " °� FIRE ALARM PERMIT APPLICATION ING`t0 Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ® New Fire Alarm Fire Alarm Alteration/Addition 17222 43RD AVE NE Project Address: Parcel ID#: Number of Zones/Panels: 1 Building Area(Sq Ft): Valuation: 800.00 Owner:LATTER DAY SAINTS CHURCH Phone Number:360-391-4130 Address: 1048 IRVINE AVE. #502 City: NEWPORT BEACH State:CA Zip Code:92660 Contact Person: Phone Number: Cell Phone: Email Address City: State: _ Zip Code Contractor:SECURITY SOLUTIONS NW Phone Number: 360-734-4940 Address 1619 N STATE ST City:BELLINGHAM State: WA Zip Code 98225 Contractor's License Number:SECURSN954JG Expiration: 4/21/23 Contact Person: DARCY BOERSMA Email: DARCYB@SSNW CO Electrical Contractor: Phone Number: Address: City State: Zip Code: Contractor's License Number: Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. OocuSigned by: V bbt,V%& 10/11/2021 r7Applicants Signature Date DARCY BOERSMA Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Rebetie WEB Form—130 Page 1 of 1 6/16LP �I� HWF2= COM SERIES LTE / IP Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire HWF2A-COM alarm control panel) with a built-in dialer. .K Models include: �•.•• HWF2A-COM(AT&T LTE&IP) HWF2V-COM(Verizon LTE&IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter(DACT). Three selectable reporting paths include:LTE cellular only,IP only,or IP primary with LTE cellular backup.All signals from the HWF2-COM Series are delivered to the AlarmNet' network control center which routes highly encrypted,cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station.The AlarmNet°network control center is fully redundant and monitored 24/7_Installation and programming are easy using the handheld 7720P Programming HWF2V-COM tool. CITY OF ARLINGTON BUILDING DEPARTMENT = APPROVED DATE ��, S' BY O NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR FEATURES AND BENEFITS • LTE and IP connection tested every day connection(LAN or WAN),DSL model or . Diagnostic LEDs indicate signal strength • Three selectable reporting paths:LTE cable modem and status cellular only,IP only,or IP Primary with LTE • Data transmits over standard Contact ID . Choice of LTE provider services cellular backup protocol but is secured with the industry's „ QOS:Quality of Service diagnostics via • Requires no change to the existing FACP advanced encryption standard(AES 256 AlarmNet conveys vital communicator configuration bit) information including signal strength, • Connects directly to the primary and • Supports both dynamic(DHCP)or public message path used,and when the message secondary telephone ports of a DACT and private Static IP addressing was received • Plan choices range from 5 minute,60 • Reliable connection:IP and cellular , 7770P Handheld programmer for easy minute,6 hour,and 24 hour supervision connection tested every day setup intervals • Built-in,standalone power supply module. • Operates overthe following communication Onboard charging circuit design protocols:LTE,HSPA+(4G)HSPA QG) accommodates battery backup.Includes • Works over any type of customer provided primary power and battery supervision Ethernet 10/100 based network Honeywell JFFICE COPY The HWF2-COM LTE/IPfire communicators operate over the most • Primary Subscriber ID(four digits),obtained from your monitoring modern and common cellular networks including LTE,4G and3G. station • Communication Module MAC ID,and MAC CRC number located on They connect to any customer provided Ethernet 10/100 base the outside of the box and inside of the module network connection(LAN or WAN),DSLorcable modem.Selectable All parameters are assigned by the monitoring station. reporting path feature allows the radios to be configured for a single or dual path,while providing appropriate supervision intervals ALARMNET based on NFPA 72 requirements.Selectable paths and supervision AlarmNet communications technology provides a highly reliable timing intervals include: alternative for the transmission of alarm signals.The network SELECTABLE DESCRIPTION SUPERVISIONJ provides extensive coverage in the United States and Canada.The PATH TIMES AlarmNet Network Control Center processes signals from powerful 2010 Cell Single path,cellular 5 Minutes servers in multiple locations equipped with 24/7 infrastructure support.Redundant hardware servers,real-time backup databases, 2010 IP Single path,IP 5 Minutes and generators with battery backup at all locations ensure 2010 IP&Cell Dual path,IP and cellular 24 Hours continuity of service.Signals from AlarmNet are transmitted to 2013 Cell Single path,cellular 60 Minutes central station receivers using multiple communication paths 2013 IP Single path,IP 60 Minutes consisting ofthe Internet,LTE radio network,ortoll free plain old telephone service(POTS).Visit AlarmNet.com to learn more. 2013 IP&Cell Dual path,IP and cellular 6 Hours INSTALLATION REQUIREMENTS,UL COMPLIANCE OPERATION To meet UL864/NFPA requirements,ensure the following: When an event occurs,the FACP goes off-hook to dial the central station.The HWF2-COM Series dialer capture module detects the ' HWF2-COM Series must be installed in accordanr_.ewith the National off-hook condition and provides the fire panelwith a dialtone,When Fire Protection Association(NFPA)standards 70 and 72 the fire panel detects the that tone,it begins dialing the central • HWF2-COM Series must be mounted in the same room and within station. 20 feet of the fire panel. HWF2-COM Series and all equipment used for the IP connection After the dialing is completed,the dialer capture module returns a (e.g.,router,hub,modem,etc)must be UL-listed,powered from an signal to the fire panel.The fire panel then sends the Contact ID unswitched branch circuit,and be provided with dpoMpria`O"standby reports to the dialer capture module,which in turn sends a signal power. after the report is successfully received from the fire panel.The • HWF2-COM Series must use the 7AH battery(not included)to dialer capture nodule sends the Contact ID reports to the HWF2- provide 24 hour backup capability CUM Series communications module.When allthe reports are sent, the fire panel goes on-hook.The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR/PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information.This is saved to the HWF2-COM communicator panel memory.When the HWF2-COM is installed at the site and connected to the Internet/ Intranet,it registers with the AlarmNet Receiver. For most installations,the only required parameters are: • Primary City ID(two digits),obtained from your monitoring station • Primary Central Station ID(two digits),obtained from your monitoring station Page 2 of 3—DH-62010:13•6/27/2019 HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Both models include: Transformer: • Red cabinet with key and lock A[armNet' is a registered • Primary:120VAC,60Hz,0.5A • Wall outlet box trademarks of Honeywel� • Secondary:18VDC,50VA • Dialer capture module International Inc,. Battery: • LTE communications module • One 12 V 7.0 AH lead-acid battery:(not • Antenna and mounting adapter Inc.All rig h ts reserved. supplied) • PowerBoostl power supply • Battery charging current:1 Amp maximum • LED display board is strictly prohibited. • Battery discharge current:Standby 230mA. • Transformer This Active 950mA • Manual and required screws document • Cables,etc. used for instakation purposes.We CABINET SPECIFICATIONS try to keep • ur product information • Dimensions:14.875"H x 12.75"W x 3.0"D ANTENNA AND EXTERNALHARDWARE (37.8cm H x 32.4cm W x 7.6cm D) •ecitic applications • Color:Red CELL-ANT3DB:3dBA gain antenna anticipate at[ requirements. WA7626-CA:SMA to N adapter cable SHIPPING DIMENSIONS 7626-50HC:50 ft.antenna cable,low loss without riotice. • Weight:5.3 lbs(6.94kg) Note:The WA7626-CA adapter cable and Country of origiw USA • Dimensions:15.625"H x 13.79"W x 9.25"D (39.7cm H x 34.9cm W x 23.9cm D) 7626-50HC antenna cable are only required when installing the CELL-ANT3DB TEMPERATURE AND HUMIDITY antenna remotely. RANGES OTHER ACCESSORIES This system meets NFPA requirements for operation at 0-490C/32-120°F and at a 7720P:HWF2V-COM,HWF2A-COM and relative humidity 93%+-2%RH(non- IPGSM-4G handheld programmer condensing at32°C+-2°C(90°F+-3°F). HPTCOVER:Plug-in transformer box for However the useful life of the system's HWF2V-COM,HWF2A-COM,and IPGSM- standby batteries and the electronic 4G communicators components may be adversely affected by BAT-1270:Battery 12 Volts,7AH,sealed extreme temperature ranges and humidity. AGENCY LISTINGS AND Therefore,it is recommended that this APPROVALS system and its peripherals be installed in an environment with a normal roam The listings and approvals below apply to temperature of 15-270C/60-801F. the HWF2-COM Series communicators.In some cases,certain modules may not be PRODUCT LINE INFORMATION listed bycertain approval agencies,or listing HWF2V-00M:LTE Digital Cellular Fire may be in process.Consult the factory for Alarm Communicator and Internet Panel, latest listings. Verizon LTE/I UL Listed:S789 HWF2A-00M:LTE Digital Cellular Fire CSFM:7300-1645:0511 Alarm Communicator and Internet Panel, FDNY:Approved AT&T LTE/I P CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE - ,, By GC THE FUTURE Is Honeywell Power Products NO CHANGES AUTHORIZED WHAT UNLESS APPROVED BY THE WE 12 Clintonville Road MAKE IT Northford,CT 06472-1610 BUILDING INSPECTOR _ www.h neywe @2019 o 19 I 06/19 Honeywell www.honeywellpower.com ©2019 Honeywell International Inc ONFICE COPY r �� n�� vi ,' � �•- ..� ti �. . ti t . � 'i t� Permit#: 4193 Permit Date: 10/15/21 Permit Type: Project Name: Latter Day Saints Church Company/Applicant Name: Security Solutions NW Company/Applicant Address: 1619 N State St City, State,Zip: Bellingham WA 98225 Contact: Darcy Boersma Phone: 360-734-4940 Email: darcyb@ssnw.co Permit Type: Fire Alarm Valuation: 800.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Install IP Fire Communicator MIC/Opportunity Zone: Permit Issued: Permit Expires: 04/13/2022 DNU: Status: IN PROCESS Assigned To: Launa Peterson Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052100304300 17222 43RD AVE NE CORP OF PRESIDING 691 Religious Activities BISHOP OF LDS (Churches Synagogues Etc. Contractors Contractor Primary Contact Phone Address Contractor Type License License# SECURITY SOLUTIONS NW 360.734.4940 1619 N STATE STREET CONTRACTOR Labor&Industries SECURSN954JG Plan Reviews Date Review Tie Description Assigned To Review Status 10/15/2021 Fire Alarm BUILDING In Review Fees Fee Description Notes Amount Fire Alarm System Permit NFPA 72- 105.7.3 $75.00 Processing/Technology Fee $25.00 Fire System Plan Review Table 4-2 or 4-10 $100.00 - Total $200.00 ���Y °� FIRE ALARM PERMIT APPLICATION 7�iING`t� Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO, INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) �❑ New Fire Alarm E] Fire Alarm Alteration/Addition Project Address:17222 43RD AVE NE Parcel ID#: Number of Zones/Panels: 1 Building Area (Sq Ft): Valuation: 800.00 Owner:LATTER DAY SAINTS CHURCH Phone Number:360-391-4130 Address: 1048 IRVINE AVE. #502 City: NEWPORT BEACH State:CA Zip Code:92660 Contact Person: Phone Number: Cell Phone: Email: Address: City: State: Zip Code: Contractor:SECURITY SOLUTIONS NW Phone Number: 360-734-4940 Address: 1619 N STATE ST City:BELLINGHAM State: WA Zip Code: 98225 Contractor's License Number: SECURSN954JG Expiration: 4/21/23 Contact Person: DARCY BOERSMA Email: DARCYB@SSNW.CO Electrical Contractor: Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. FV DocuSigned by:o r �°jMrSwta. 10/11/2021 33B1D4E77E6D4E7Applicants Signature Date DARCY BOERSMA Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/16LP CITY OF ARLINGTON • 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17222 43RD AVE NE Permit#: 4193 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052100304300 DATE OF ISSUANCE. Scope of Work: Install IP Fire Communicator Valuation: 800.00 OWNER APPLICANT CONTRACTOR CORP OF PRESIDING BISHOP OF Security Solutions NW SECURITY SOLUTIONS NW LDS 50 E NORTH TEMPLE ST 22ND 1619 N State St 1619 N STATE STREET FLOOR SALT LAKE CITY,UT 84150-3620 Bellingham WA 98225 BELLINGHAM,WA 98226 360-734-4940 360.734.4940 LIC:SECURSN954JG EXP:04/07/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR SECURITY SOLUTIONS NW 1619 N STATE STREET BELLINGHAM,WA 98226 360.734.4940 LIC#: SECURSN954JG EXP: 04/07/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC IO/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET II certification upon request.2.Trouble condition to be verified for signaling circuits.3. Signal transmission to Central Station Monitoring Company to be verified.4.Installation completion form shall be submitted to The Compliance Engine prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/18/2021 Fire Alarm System Permit $75.00 10/18/2021 Processing/Technology Fee $25.00 10/18/2021 Fire System Plan Review $100.00 Total Due: $200.00 Total Payment: $0.00 Balance Due: $200.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon " SECURITY S 0 L U T 1 0 N S 10/1/2021 Scope of Work: Adding Honeywell radio/cell communication to existing Siemens PMI-2 fire alarm panel to remove phonelines. r i _ t • 0 0 0 Location: Main floor electrical room. Bellingham Lock&Safe,A Part of Security Solutions—Locally Owned for Over 100 Years 1619 N. State Street Ph: 360.734.4940 www.securitysolutionsnw.com Bellingham, WA 98225 Fax: 360.647.9540 Page- I 4Wo,, __q"00 M S E R I ES LTE / IP Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire HWF2A-COM alarm control panel) with a built-in dialer. Models include: „o HWF2A-COM(AT&T LTE&IP) HWF2V-COM(Verizon LTE&IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter(DACT). Three selectable reporting paths include:LTE cellular only,IP only,or IP primarywith LTE cellular backup.All signals from the HWF2-COM Series are delivered to the AlarmNet° network control centerwhich routes highly encrypted,cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station.The AlarmNet°network control center is fully redundant and monitored 24/7.Installation and programming are easy using the handheld 7720P Programming tool. HWF2V-COM �Ya FEATURES AND BENEFITS • LTE and IP connection tested every day connection(LAN or WAN),DSL model or • Diagnostic LEDs indicate signal strength • Three selectable reporting paths:LTE cable modem and status cellular only,IP only,or IP Primarywith LTE • Data transmits over standard Contact ID . Choice of LTE provider services cellular backup protocol but is secured with the industry's • QOS:Quality of Service diagnostics via • Requires no change to the existing FACP advanced encryption standard(AES 256 configuration bit) AlarmNet conveys vital communicator information including signal strength, • Connects directly to the primary and • Supports both dynamic(DHCP)or public message path used,and when the message secondary telephone ports of a DACT and private Static IP addressing was received • Plan choices range from 5 minute,60 • Reliable connection:IP and cellular 7720P Handheld programmer for easy minute,6 hour,and 24 hour supervision connection tested every day setup intervals • Built-in,standalone power supply module. • Operates overthe following communication Onboard charging circuit design protocols:LTE,HSPA+(4G)HSPA(3G) accommodates battery backup.Includes • Works over any type of customer provided primary power and battery supervision Ethernet 10/100 based network Honeywell The HWF2-COM LTE/IP fire communicators operate over the most • Primary Subscriber ID(four digits),obtained from your monitoring modern and common cellular networks including LTE,4G and3G. station • Communication Module MAC ID,and MAC CRC number located on They connect to any customer provided Ethernet 10/100 base the outside of the box and inside of the module network connection(LAN or WAN),DSL or cable modem.Selectable All parameters are assigned by the monitoring station. reporting path feature allows the radios to be configured for a single or dual path,while providing appropriate supervision intervals ALARMNET based on NFPA 72 requirements.Selectable paths and supervision AlarmNet communications technology provides a highly reliable timing intervals include: alternative for the transmission of alarm signals.The network ELECTABLE r:: PTION 'I SUPERVISI provides extensive coverage in the United States and Canada.The PATH TIMES AlarmNet Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure 2010 Cell Single path,cellular 5 Minutes support.Redundant hardware servers,real-time backup databases, 2010 IP Single path,IP 5 Minutes and generators with battery backup at all locations ensure 2010 IP&Cell Dual path,IP and cellular 24 Hours continuity of service.Signals from AlarmNet are transmitted to 2013 Cell Single path,cellular 60 Minutes central station receivers using multiple communication paths 2013 IP Single path,IP 60 Minutes consisting of the Internet,LTE radio network,or toll free plain old telephone service(POTS).Visit AlarmNet.com to learn more. 2013 IP&Cell Dual path,IP and cellular 6 Hours INSTALLATION REQUIREMENTS,UL COMPLIANCE OPERATION To meet UL864/NFPA requirements,ensure the following: When an event occurs,the FACP goes off-hook to dial the central HWF2-COM Series must be installed in accordancewith the National station.The HWF2-COM Series dialer capture module detects the off-hook condition and provides the fire panelwith a dialtone.When Fire Protection Association(NFPA)standards 70 and 72 the fire panel detects the dial tone,it begins dialing the central ' HWF2-COM Series must be mounted in the same room and within station. 20 feet of the fire panel. • HWF2-COM Series and all equipment used for the IP connection After the dialing is completed,the dialer capture module returns a (e.g.,router,hub,modem,etc)must be UL-listed,powered from an signal to the fire panel.The fire panel then sends the Contact ID unswitched branch circuit,and be provided with appropriate standby reports to the dialer capture module,which in turn sends a signal power. after the report is successfully received from the fire panel.The • HWF2-COM Series must use the 7AH battery(not included)to dialer capture nodule sends the Contact ID reports to the HWF2- provide 24 hour backup capability COM Series communications module.When allthe reports are sent, the fire panel goes on-hook.The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR/PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information.This is saved to the HWF2-COM communicator panel memory.When the HWF2-COM is installed at the site and connected to the Internet/ Intranet,it registers with the AlarmNet Receiver. For most installations,the only required parameters are: • Primary City ID(two digits),obtained from your monitoring station • Primary Central Station ID(two digits),obtained from your monitoring station Page 2 of 3—DH-62010:13•6/27/2019 HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Both models include: Transformer: • Red cabinet with key and lock AlarmNetO is a registered • Primary:120VAC,60Hz,0.5A • Wall outlet box trademarks of Honeywell • Secondary:l8VDC,50VA • Dialer capture module International Battery: • LTE communications module @2019 by • - International • One 12 V 7.0 AH lead-acid battery:(not • Antenna and mounting adapter Inc.All rights -• supplied) • PowerBoostl power supply Unauthorized use of document • Battery charging current:1 Amp maximum • LED display board is strictly prohibited. • Battery discharge current:Standby 230mA, • Transformer Active 950mA • Manual and required screws This document 't intended to be • Cables,etc. used for installationpurposes. CABINET SPECIFICATIONS try to keep our •• information - HARDWARE • Dimensions:14.875"H x 12.75"W x 3.0"D ANTENNA AND EXTERNALup-to-date" • accurate. • cover all specific (37.8cm H x 32.4cm W x 7.6cm D) applications • Color:Red CELL-ANT3DB:3dBA gain antenna anticipate all requirements.All WA7626-CA:SMA to N adapter cable specifications are subjectto change SHIPPING DIMENSIONS 7626-50HC:50 ft.antenna cable,low loss without notice. • Weight:5.3 lbs(6.94kg) • Dimensions:eight: .3lbs .625"H x 13.79"W x 9.25"D Note:The WA7626-CA adapter cable and • • • • ' (39.7cm H x 34.9cm W x 23.9cm D) 7626-50HC antenna cable are only required when installing the CELL-ANT3DB TEMPERATURE AND HUMIDITY antenna remotely. RANGES OTHER ACCESSORIES This system meets NFPA requirements for operation at 0-49°C/32-1201F and at a 7720P:HWF2V-COM,HWF2A-COM and relative humidity 93%+-2%RH(non- IPGSM-4G handheld programmer condensing at 32°C+-21C(901F+-31F). HPTCOVER:Plug-in transformer box for However the useful life of the system's HWF2V-COM,HWF2A-COM,and IPGSM- standby batteries and the electronic 4G communicators components may be adversely affected by BAT-1270:Battery 12 Volts,7AH,sealed extreme temperature ranges and humidity. AGENCY LISTINGS AND Therefore,it is recommended that this APPROVALS system and its peripherals be installed in an environment with a normal room The listings and approvals below applyto temperature of 15-271C/60-801F. the HWF2-COM Series communicators.In some cases,certain modules may not be PRODUCT LINE INFORMATION listed bycertain approval agencies,or listing HWF2V-COM:LTE Digital Cellular Fire may be in process.Consult the factory for Alarm Communicator and Internet Panel, latest listings. Verizon LTE/I UL Listed:S789 HWF2A-COM:LTE Digital Cellular Fire CSFM:7300-1645:0511 Alarm Communicator and Internet Panel, FDNY:Approved AT&T LTE/I THE FUTURE Is Honeywell Power Products WHAT WE 12 Clintonville Road MAKE E IT Northford,CT 06472-1610 203.484.7161 DH-62010 I e 1 06/19 www.honeywellpower.com ©2019 Honeywell International Inc. Honeywell ll Permit#: 4193 Permit Date: 10/15/21 Permit Type: FIRE ALARM Project Name: Latter Day Saints Church Applicant Name: Security Solutions NW Applicant Address: 1619 N State St Applicant, City, State, Zip: Bellingham WA 98225 Contact: Darcy Boersma Phone: 360-734-4940 Email: darcyb@ssnw.co Scope of Work: Install IP Fire Communicator Valuation: 800.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 04/13/2022 Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CORP OF 691 Religious 31052100304300 17222 43RD AVE NE PRESIDING Activities(Churches BISHOP OF LDS Synagogues Etc. Contractors Contractor Primary Contact Phone Address Contractor Type License License# SECURITY 4940 1619 N STATE CONSTRUCTION Labor& SECURSN954JG SOLUTIONS NW 360.734. STREET CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 11/22/2021 FA00.FIRE ALARM Fire Alarm Radio 11/23/2021 11/23/2021 BUILDING Approved FINAL installation final-anytime between 10 and noon Plan Reviews Date Review Type Description Assigned To Review Status 10/15/2021 FIRE ALARM BUILDING Fees Fee Description Notes Amount Fire Alarm System Permit NFPA 72- 105.7.3 $75.00 Processing/Technology $25.00 Fire System Plan Review Table 4-1 $100.00 Credit Card Service $6.00 Total $206.00 Attached Letters Date Letter Description 10/18/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/18/2021 Darcy Boersma 89173175 $200.00 10/18/2021 89173175 Ameresia Lawlis $6.00 Outstanding Balance $0.00 Uploaded Files Date File Name 10/20/2021 9938680-4193 Permit for signature.pdf 10/15/2021 9908443-4193 SOWpdf 10/15/2021 9908444-4193 Specs.pdf 10/15/2021 9908445-4193 Application.pdf