Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
8109 Crown Ridge Blvd_BLD4175_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 _ BUILDING PERMIT 8109 CROWN RIDGE BLVD Permit#:5975 Parcel#:00904500000600 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:6.56 kW PV Solar Panel Installation on Roof Valuation:31460.58 APPLICANT CONTRACTOR VANDEBOGART PAUL L&DIANE M BR Field Ops,LLC BRS Field Ops,LLC dba Blue Raven Solar 8109 CROWN RIDGE BLVD 1403 N Research Way 1403 N Research Way ARLINGTON,WA 98223-4020 Orem Orem,UT 87097 3854820045 385-482-0045 LIC:604 276 519 EXP:07/31/2024 LIC:BRSFV0820N3 EXP:08/23/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: SOLAR INSTALLATION CODE YEAR: 2021 STORIES: 2 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 0&QG �Guti 05/20/2024 Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspection.Adhere to approved plans.call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/20/2024 Building Plan Review $450.40 05/20/2024 Credit Card Service $13.51 05/20/2024 Processing/Technology $25.00 05/20/2024 Building Permit $684.70 05/20/2024 State Surcharge-1st DU $6.50 Total Due: $1,180.11 Total Payment: $1,180.11 Balance Due: $0.00 CALL FOR INSPECTIONS 14 Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i RESIDENTIAL PHOTOVOLTAIC SOLAR PANEL ` Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 The City of Arlington requires a building permit to install Photovoltaic (PV) Solar Panel(s) for residential and commercial uses.This policy governs Residential uses only. Other permits may be required per Washington State Labor and Industries or Utility Providers. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING: REQUIRED DOCUMENTS City of Arlington Solar Panel Application Roof Plan and Construction Documents Manufacturer's installation specifications Engineering, (if required) Type of Permit: [D New Installation ❑ Addition ❑ Replacement Property Address: 8109 Crown Ridge Blvd,ARLINGTON,Washington, 9091ect Valuation: 5918.43 Lot#: 6 Parcel ID No.: 00904500000600 Subdivision: Crown Ridge Est Div2 Project Scope of Work: 6.56 kW PV Solar Panel Installation on Roof Primary Contact: ❑ Owner 21 Contractor Owner Name: Mike Lamb Home No.: Email Address: gr8mike@yahoo.com Cell No.: +13606312945 Mailing Address: 8109 Crown Ridge Blvd City: ARLINGTON State: WA Zip: 98223 Contractor Name: BRS Field Ops, LLC Office No.: Email Address: permitting.department@blueravensolar.com Cell No.: 385-482-0045 Mailing Address: 1403 N Research Way City: Orem State: LIT Zip: 84097 L&I Contractor License Number: BRSFIF0820N3 Expiration Date: 08/23/24 Existing Roof Structure: Existing Roof Material: Comp Shingle/Asphalt Building Square Footage: 341.36 Number of Stories: 2 INSPECTION REQUIREMENTS Roof mount panels require two(2) inspections minimum 1. The first inspection is for the roof mount racking hardware to verify compliance and attachment. (You may schedule this inspection for the day the panels are being installed. You may begin mounting panels over the racking prior to inspection but there must be enough racking exposed for the inspector to verify compliance.) 2. The final inspection shall be scheduled when the project is complete and after Labor and Industries has approved the electrical. I hereby certify that 1 am the ❑ Owner S Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington. Permitting Coordinator rGrozupsozc Amber Thompson 05 / 02 / 2024 Signature Print Name Date SAVE PRINT Dom u S Dom Ls Structural Engineering, LLC T R t) C T U. R A 1, P.O .Box 560 Broom field, CO 80038 E- N G E N E E? R E N G i. 1. C 530-864-7055 projects@dom Lsstruc.com M ay 2,2024 To: Blue Raven Solar 1403 North Research Way,Building Orem,UT.84097 Subject: Certification Letter Lam bResidence 8109 Crown Ridge Blvd Arlington,WA 98223 To Whom It M ay Concern, A jobsite observation of the condition of the existing fram ling system was perform ed by an audit team of Blue Raven Solar as a request from Dom u;Structural Engineering.All review is based on these observations and the design criteria listed below and only deem ed valid if provided inform ation is true and accurate. On the above referenced project,the roof structural fram hg has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elem efts.The observed roof fram hg is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structure of(M Pl)consists of com position shingle on roof plywood that is supported by pre-m aiufactured trusses that are spaced at @ 24"o.c..The top chords,sloped at 18 degrees,are 2x4 sections,the bottom chords are 2x4 sections and the web m en hers are 2x4 sections.The truss m en bers are connected by steel gusset plates.The m ac unsupported projected horizontal top chord span is approxim a:ely 7'-0". The existing roof fram hg system of(M Pl)is judged to be adequate to withstand the loading im posed by the installation of the solar panels.No reinforcem eit is necessary. The spacing of the solar standoffs should be kept at 72"o.c.for landscape and 48"o.c.for portrait orientation,with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly lim ted to an evaluation of the fastener attachm eit,underlying fram hg and supporting structure only.The attachm efts to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading.All panels,racking and hardware shall be installed per m aiufacturer specifications and within specified design lim Cations.All waterproofing shall be provided by the m aiufacturer. Dom u;Structural Engineering assum e;no responsibility for m tuse or im proper installation of the solar PV panels or racking. A'Design Criteria: c4t • Applicable Codes=2015 IBC/IRC,ASCE 7-10 �� O WAs�ti • Roof Dead Load=7 psf(M Pl) • Roof Live Load=20 psf • Wind Speed=110 m ph(Vult),Exposure C,Risk Category II • Roof Snow Load=25 psf • Attachm Ent:1-5/16 dia.lag screw with 2.5 inch m h.em bedm ant 46056 depth,at spacing shown above. �S�ONAL Please contact m ewith any further questions or concerns regarding this project. Sincerely, Digitally signed by John A. Calvert John Calvert,P.E. Date: 2024.05.02 Project Engineer 10:02:37 -06'00' Lam bArlington WA 1 Dom u S Dom us Structural Engineering, LLC T R t) C T U. R A 1, P.O .Box 560 Broom Feld, CO 80038 E- N G E N E E? R E N G i. 1. C, 530-864-7055 projects@dom usstruc.com G ovity Loading Roof Snow Load Calculations p9=Ground Snow Load= 25.0 psf pf=0.7 Ce Ct I p9 (ASCE7-Eq 7-1) Ce=Exposure Factor= 1 ( ASCE7-Table 7-2) Ct=Thermal Factor= 1 ( ASCE7-Table 7-3) 1=Importance Factor= 1 pf=Flat Roof Snow Load= 25.0 psf ps=CSpf (ASCE7-Eq 7-2) Cs=Slope Factor= 1.00 ps=Sloped Roof Snow Load= 25.0 psf PV Dead Load=3 psf(Per Blue Raven Solar) DL Adjusted to 18 Degree Slope 3.15 psf PV System W tight W tight of PV System(Per Blue Raven Solar) 3.0 psf X Standoff Spacing= 4.00 ft Y Standoff Spacing= 6.08 ft Standoff Tributary Area= 24.33 sft Point Loads of Standoffs 73 lb Note:PV standoffs are staggered to ensure proper distribution of loadinc Roof Live Load=20 psf Note:Roof live load is removed in area's covered by PV array. Roof Dead Load(MP1) Composition Shingle 4.00 psf Roof Plywood 2.00 psf 2x4 Top Chords @ 24"o.c. 0.73 psf Vaulted Ceiling 0.00 psf (Ceiling Not Vaulted) Miscellaneous 0.27 psf Total Roof DL(MP1) 7.0 psf DL Adjusted to 18 Degree Slope 7.4 psf Lam bArlington WA 2 Dom u S Dom us Structural Engineering, LLC T R t) C T U. R A 1, P.O .Box 560 Broom field, CO 80038 E- N G E N E E? R E N G i. 1. t_ 530-864-7055 projects@dom usstruc.com Wind Calculations Per ASCE 7-10 Com ponents and Cladding Input Variables W hd Speed 110 mph Exposure Category C Roof Shape Hip/Gable Roof Slope 18 degrees Mean Roof Height 20 ft Effective W hd Area 21.3 ft Design W hd Pressure Calculations W hd Pressure P=qh*G*Cn qh=0.00256*Kz*Kzt*Kd*V^2 (Eq.30.3-1) Kz(Exposure Coefficient)=0.9 ( Table 30.3-1) Kzt(Topographic Factor)= 1 ( Fig.26.8-1) Kd(W hd Directionality Factor)= 0.85 ( Table 26.6-1) V(Design W hd Speed)=110 mph ( Fig.26.5-1A) Risk Category=11 ( Table 1.5-1) qh= 23.70 psf 0.6*qh= 14.22psf Standoff Uplift Calculations-Portrait Zone 1 Z one 2 Z one 3 P ositive GCp= 0.85 - 1.52 - 2.42 0 .43 ( Fig.30.4-1) Uplift Pressure= 12.07 psf -21.65 psf -34.39 psf 10.1 psf X Standoff Spacing= 4 .00 ft 4 .00 ft 2 .67 ft Y Standoff Spacing= 6 .08 ft 3 .04 ft 3 .04 ft Tributary Area= 2 4.33 sgft 12.17 sgft 8.11 sgft Dead Load on Attachment= 73 lb 3 7 Ib 2 4 Ib Footing Uplift(0.6D+0.6W p - 250 lb - 242 lb - 264 lb Standoff Uplift Calculations-Landscape Zone 1 Z one 2 Z one 3 P ositive GCp= 0.85 - 1.52 - 2.42 0 .43 ( Fig.30.4-1) Uplift Pressure= 12.07 psf -21.65 psf -34.39 psf 10.0 psf (Minimum) X Standoff Spacing= 6 .00 ft 6 .00 ft 4 .00 ft Y Standoff Spacing= 3 .50 ft 1 .75 ft 1 .75 ft Tributary Area= 2 1.00 sgft 10.50 sgft 7.00 sgft Dead Load on Attachment= 63 lb 3 2 Ib 2 1 lb Footing Uplift(0.6D+0.6W)= - 216 lb - 208 lb - 228 lb Standoff Uplift Check Maximum Design Uplift=-264 lb Standoff Uplift Capacity =450 lb 450 lb capacity>264 lb demand Therefore,OK Fastener Capacity Check Fastener= 1-5/16"dia.lag Number of Fasteners= 1 Embedment Depth= 25 in. Pullout Capacity Per Inch= 250 lb Fastener Capacity= B5 lb w/F.S.of 1.5&DOL of 1.6= (67 lb 667.2 lb capacity>264 lb demand Therefore,OK Lam bArlington WA 3 Dom u S Dom us Structural Engineering, LLC T R t) C T U. R A 1, P.O .Box 560 Broom field, CO 80038 E- N G E N E E? R T N G i. 1. C, 530-864-7055 projects@dour usstruc.com Framing Check (M P1) PASS w=71 plf Dead Load 7 .4 p;f PV Load 3 .2 pBf Snow Load 2 5.0 p;f 2x4 Top Chords @ 24"o.c. O Governing Load Combo=DL+SL Member Span=T-0" \ Total Load 3 5.5 Isf Member Properties Member Size S(in^3) I(in^4) Lumber Sp/Gr Member Spacing 2x4 3.06 D 5.36 F#2 @ 24"o.c. Check Bending Stress Fb(psi)= f 'b x C d x C f x C r ( NDS Table 4.3.1) 900x 1 .15x1 .5x1 .15 Allowed Bending Stress=1785.3 psi Maximum M oment =(wL12)/8 = 435.0541 ft# = E220.649 in# Actual Bending Stress=(Maximum Moment)/S =1704.8 psi Allowed>Actual--95.5%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = L/180 (E=1600000 psi Per NDS) = 0466 in Deflection Criteria Based on = Continuous Span Actual Deflection(Total Load) _ (w'L^4)/(185`E'I) =0.186 in = U452 >L /180 Therefore OK Allowed Deflection(Live Load) = L/240 0.35 in Actual Deflection(Live Load) _ (w'L^4)/(185'E'I) 0.131 in L/642 >L /240 Therefore OK Check Shear Member Area=5:3 inA2 v(psi)= 180 psi ( NDS Table 4A) Allowed Shear = Fv A = 945 lb ax Shear(V)=w*L 12 = 2 49 lb Allowed>Actual--26.4%Stressed -- Therefore,OK Lam bArlington WA 4 Do m u S Dom us Structural Engineering, LLC T R t) C T U. R A 1, P.O .Box 560 Broom field, CO 80038 -E- N G E N E E? R E N G i. 1. C 530-864-7055 projects@dom usstruc.com Lateral Check Existing W dght of Effected Building Level A e rea W ight(psi) ight(lb) Roof 1598 sf 7.4 psf 1 1762 lb Ceiling 1 598 sf 6 .0 psf 9 588 lb W owd Siding 100 ft 5.0 psf 2 000 lb ( 8'-0"W dl Height) Int.W dls 1 1 00 ft 6 1 .4 psf 2 560 lb Existing W dght of Effected Building 25910 lb Proposed W dght of PV System W dght of PV System(Per Blue Raven Solar) 3.0 psf Approx.Area of Proposed PV System 341 sf Approximate Total W dght of PV System 1023 lb 10%Comparison 10%of Existing Building W dght(Allowed) 2591 lb Approximate W dght of PV System(Actual) 1023 lb Percent Increase 3.9% 2591 lb>1023 lb,Therefore OK Lam bArlington WA 5 Dco m Tf S Dom us Structural Engineering, LLC -S- TRUCTE` RAL P.O .Box 560 ENGINEERT N G T. T. C Broom field, CO 80038 530-864-7055 projects@dom usstruc.com Appendix A:G Eieral Notes G ENERAL • The contractor shall verify all dim Ensions,property setbacks,AHJ/HO ACC&R's,elevations and site conditions before starting work and shall notify Dom Ls Structural Engineering,LLC of any discrepancies. • All report conclusions represent Dom ns Structural Engineering,LLC's best professional judgm Ent based upon industry standards. • Resolve any conflicts on the drawings with Dom is Structural Engineering,LLC before proceeding with construction. • The design criteria used for this project&listed on the first page of the report is based on the engineers best judgem ant and/or provided by the ATC council.AHJ specific requests m ay differ.Please contact our team if the design criteria needs to be m odified. • A site visit was not physically conducted by Dom Ls Structural Engineering,LLC.The accompanying calculations and certification are provided with the understanding that the site building and construction standards meet an acceptable level of industry standards.It shall be the contractors responsibility to identify any irregularities such as inconsistent Pram hg conditions,water dam age,fire dam age,cracked,split or noticeably deflecting Pram hg m an bars. • Dom Ls Structural Engineering,LLC is not responsible for enforcing safety measures or regulations.The contractor shall design,construct,and maintain all safety devices including shoring and bracing,and shall be solely responsible for conform hg to all local,state and federal safety and health standards,laws and regulations.The contractor shall take necessary precautions to m antain and insure the integrity of the structure during construction.If a lawsuit is filed by one of the contractor's or subcontractor's em poyees,or any one else,the contractor will indem rify,defend and hold the owner and Dom is Structural Engineering,LLC harm lass of any and all such claim S • Any and all waterproofing shall be provided by the contractor.Dom u;Structural Engineering,LLC is not responsible for waterproofing. • All hardware shall be installed per m anufacturer specifications and within specified design lim Cations.Dom Ls Structural Engineering,LLC assum es no responsibility for incorrectly installed hardware or hardware installed outside of the m anfacturer specifications. USER RELIANCE Dom Ls Structural Engineering,LLC was engaged by Blue Raven Solar(Client)to perform this assessm Ent.This report and the inform ation therein,are for the exclusive use of the Client.This report has no other purpose and shall not be relied upon, or used,by any other person or entity without the written consent of Dom Ls Structural Engineering,LLC.Third parties that obtain this report,or the inform ation within shall have no rights of recourse or recovery against Dom is Structural Engineering,LLC,its officers or em ployees. RO O RN O WTED ARRAYS If an analysis of a supporting stucture is included in our scope of work,the structural assessm ant only applies to the section of the roof that is directly supporting the proposed solar PV system. No structural m an bars can be cut for conduit,etc.,unless specifically shown.O ttain prior written approval for installation of any additional conduit,etc. It is assumed that a standard quality of construction care was used to construct the original building.It shall be the contractors responsibility to field verify any and all fram hg m Em bars supporting the proposed PV array are in adequate condition.The contractor shall field inspect for sub-standard construction m Eros,signs of dry rot,m cid,fire dam age,etc.and notify engineer if any com prom bed m aerial is found on site prior to starting construction. e It is assum ed that there have been no additional loads(HVAC or M EP equipm ant,additional layers of roofing,etc)added to the building over the course of the structure's histroy.The contractor and/or client shall verify this with the property owner and notify Dom is Structural Engineering,LLC if additional load has been added to the structure already. Flexible utility connections m ust be used at any building seism b joint. Care should be taken to ensure that PV arrays do not preclude drainage of rain water. Unless otherwise noted,construction material shall be evenly distributed if placed on framed floors or roofs.Loads shall not exceed the allowable loading for the supporting m an bers and their connections. All lags or wood screws at the roof shall be stainless steel and installed withing the m ddle 1/3 of the dim ensional width of the fram hg m an bers. All fasteners shall be a m him urn of 6"away from any truss panel or hinge joints,truss plates and/or m En ber ends.Field verify location of fasteners prior to starting construction.All fasteners shall be pre-drilled to avoid splitting existing lum bar. Dom is Structural Engineering,LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array nor any dam age to downslope decks,roofs,walkways,landscaping,autom cbiles,pets,people,etc..If snow guards are requested by the custom a,notify Dom u;Structural Engineering,LLC. Lam bArlington WA 6 RESIDENTIAL RO O Ff0 P SO LAR PERM IT PAC KAG E Enphase Platinum BLUE RAVEN d06 Mike Lamb Installer ' qLAIR 8109 C row n Ridge Blvd 1403 N 630 E PV Installation Orem, Utah 84097 Professional A R L I N G TO N, Washington 98223 SUN Fb W E R° Blue RaOvenSolar8.ccom Scott Gurney + 13606312945 Authorized '•' - #PV-01 1 71 9-01 5866 SC O E O FWORC �' �:� �= ' SHEET INDEX o INSTALLATIO N O F RO O FfO P M O UNTED ��� ,� r. . ► PVI C O\ER SHEET :D PHOTOVOLTAIC SOLAR SYSTEM ��� `" PV2 SITE PLAN PV3 RO O FPLAN U y PV4 STRUC 7URAL N PV5 ELEC 7RIC AL 3-LINE N N PV6 ELECTRICAL CALCLLATIONS -0 " 0 PV7 LABELS m C Q N PV8 PLACARD O 3 } � SS SPEC SHEETS 0) C } J N C U rCL Q U z } 1l � 0Q o A E O li4 , Sealed For -C 1 Existing Roof& a z C Attachment O dy Z 0 `" � o U TYPIC AL STRUC URAL INFO RMATIO N NEW PV SYSTEM INFO RMATIO N TOTAL PV DC SYSTEM SIZE T OTAL PV AC SYSTEM SIZE s U Q ROOFMATERIAL: Can pShingle DC SYSTEM SIZE: 6.56 kW DC 6560 kW DC 5.200 kW AC PRO JECTID: SHEATHING TYPE: OSB AC SYSTEM SIZE: 5.2 kW AC . FRAMING TYPE: Manufactured Truss A 936575 RAC IGNG TYPE: UNIRAC SFM INFINITY MO DOLE TYPE: (16) Silfab Solar SIL-410 HC + .� W C91 y DESIGN C RTERIA ATTAC FINIENT TYPE: UNIRAC SFM INFINITY FLASHKIT INVERTER TYPE: En phase IQ W- - -72MUS O �ti PV DCSIZE: TOTAL ATTAC HMENTS: 39 p '\ '� � WIND SPEED: 1 10 6.560 6.560 kW DC p WIND EXPO SU RE FAC 10 R C PV AC SYSTEM SIZE: RISK C ATEG OR`: II 5.200 kW AC GENERAL NOTES G RO LIND SNO W LO AD: 25 REVISIONS: RO O FSNO W LO AD: 25 I "056 SEISM IC DESIG N C MEG O W: D A -- B �SS70NAL �'�e�`' W EATH ER STATIO N DATA 0 ---- W EATHER STATIO N: BO BNG FLD KING C O ZL HIG H TEMP 2%AVG:29°C DRAWN BY: 5/2/2024 EXTREM E M INIM UM TEM P: -7°C Brendan Fillm ore Digitally signed by . PLOTDATE: AHJ APPLIC ABLE C O [IS May 2, 2024 C y of Arlington WA n aver *2020 NATIONAL ELEC]RICCOEl (NEC) DRAWING TITLE: Date- 2024 OS 09 — *2015 INTERNATIONAL BUILDING C O EE (IBC) C over Sheet *2015 INTERNATIONAL RESIDENTIAL C O EE (IRC),2015 INTERNATIONAL UTILITY C O MANY 0.03. $ -O6 OO PLUMBING C O EE (IPC),AND ALL STATE AND LOCAL BUILDING,ELEC 1RIC AL, AND PLUMBING C O DES DRAWING NUMBER: Snohomish C aunty Public Utilities District (PUD) PV1 BLUE RAVEN SOLAR — 1403 N 630 E Orem, Utah 84097 I (800) 377-4480 I BlueRavenSolar.com I I I I � I � I I }_o co CV � 0 N ° Sealed For c Q N ° Existing Roof & O° 0 3 I El ° ° -1 � � Attachm ent O dy o } I 0 0 0 I ® ® waCs�9l c{.p G U0J O oUcB () a A _� Z M m ) Q E I 46056 O I 4,Cf� � y > O I S'OIVAL Er Z -4 cn I O 0 > I I 5/2/2024 J u a PRO.EC TID: 936575 PV DC SYSTEM SIZE: 6.560 kW DC FRONT OF HOME PV AC SYSTEM SIZE: 5.200 kW AC 8109 C row n Ridge Blvd REVISIONS: 0 ---- 0 ---- SITE PLAN 0 ---- SC ALE: 1/16"= V-0" 0 D LEG END PV SYSTEM SPEC FIC ATIO NS C O MA►SS DRAWN BY: Brendan Fillmore ' ROOFTOP FBE] BREAKER FATS] G ENERATO R RPO REMOTE POWER TRENC H O R NEW PV SYSTEM INFORMATION _\ PLOTDATE: JUNC TO N BOX ENC LOSURE ATS PANEL O FF SWITC H OVERHEAD PV MODULE: (16) Silfab Solar SIL-410 HC t PO W IR RATING:410 W \ ! May 2, 2024 MIC RONVERTER: Enphase IQ8M-72-M-US, POWIR RATING:325 W ` DRAW ING TITLE: IM] UTILITY METER AC AC DISCO WEC T IC IT UTILITY TC ABIN METER RE HIATC H SETBAC K i PROPERTY LINE Site Plan FS MAIN SERVICE PV PV PRO DUC TON BAT ESS - BATTERY MIC ROINVERTER NEWDRAWING NUMBER: PANEL METER PV SYSTEM 11H SUBPANEL H C 0 M BNER BO X E ESS-C 0 JRO LLER IC O1$WINTERIORLTH DO TrED O 910 P V INDIC,4TE INTERIO R LO C<PIO N S BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com ❑ 0 ❑ cy U ❑ ❑ SKYLIGHT N N 00 ❑ > Q cn O m oO 3 N EO) � � } O ::D • ® ® ® Sealed For Q Z 14-Q IL ® ® ® Existing Roof & CC— U o O ® ® ® Attachm ent O riy G o CD U 0o Z U J � ® ® � ® Q N PAI ® `Z`� Aw C,q l L o O o� Ash '� Z c B Ag 0 u AC M P1 u a M MSPI MODULE QTY: 16 1' R 46056 PRO.EC TID: AZIMUTH: 211 E�'��° � 936575 PITCH 18 S�OIYAi - G� UNDERG RO UND SERVIC E LINE TS R F: 95 PV DC SYSTEM SIZE: AREA: 617 ft2 6.560 kW DC PO NT O F INTERC O NNEC 110 N 5/2/2024 PV AC SYSTEM SIZE: 5.200 kW AC REVISIONS: FRONT OFHOME 0 ---- 0 ---- RO O FPLAN 0 ---- SC ALE: 1/8"= 1'-0" LEG END PV SYSTEM SPEC FIC ATIO NS C O MASS DRAWN BY: Brendan Fillmore ' ROOFTOP FBE] BREAKER FATS] G ENERATO R RPO REMOTE POWER TRENC H O R NEW PV SYSTEM INFORMATION _\ PLOTDATE: JUNC TO N BOX ENC LOSURE ATS PANEL O FF SWITC H OVERHEAD PV MODULE: (16) Silfab Solar SIL-410 HC t PO W IR RATING:410 W \ ! May 2, 2024 MIC RONVERTER: Enphase IQ8M-72-M-US, POWIR RATING:325 W ` DRAW ING TITLE: UTILITY METER AC AC DISCO WEC T IC IT UTILITY TC ABINETR RE HIATC H SETBAC K i PROPERTY LINE Roof Plan FS MAIN SERVICE PVPV PRO DUC TON BAT ESS - BATTERY MIC ROINVERTER NEWDRAWING NUMBER: PANEL METER ❑ PV SYSTEM ICO1$WITH DO1RLO P V SUBSUBPANEL C B BJ C O M ER BOX EESS-C O rTRO LLER INDIC,4TE INTERIORLOC 9<P10 ION CD J C BUNG JOIST/ MAXIMUM MAXIMUM TOTAL PV ARRAY AREA(ff') 341.36 PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE ROOFMATERIAL S HEATHINGTYPE F RAM ING TYPE PURLINS SIZE RAC gNGTYPE A TTACHIA ENT TYPE ATTAC FMENT CIWTILEVER TOTAL FAREA ) 1598 C O WT (DEG) (DEG) (%) (ft') AND SPAC NG AND SPAC ING SPAC ING(S) (C) DISTRIBUTEDTED LOAD(psfpsf) 2.2.2 MPl 16 2 11 1 8 9 506 17 C S mp Shingle O a B M nufactured Truss 2 x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY U NIRAC SFM INFINITY FLASHKIT 7 2"L/48"P 2 4"L/16P ROO FC O IERAG E(%) 21.36 MP2 0 TOTAL PV ARRAY WEIGM(lbs) 752 BLUE RAVEN MP3 0 TOTAL PV ATTAC FMENTS 39 MP4 1 0 PO NT LOAD(lbs/aft.) 19.3 S O LA R MPS 0 M P6 0 1403 N 630 E MP7 0 Orem, Utah 84097 MP8 0 (800) 377-4480 MP9 0 BlueRavenSolar.com MP10 0 ATTAC WENT TYPE: PV MODULES SHALL NOT EXTEND Unirac SFM Infinity ABOVE ROO FRIDG E LINE 0 PV MODULE MAX C ANTI LEVER } PER TABLE ABOVE (y) U (C) UNIRAC UNIRAC 00 PV MODULE SFM INFINITY SFM INFINITY 0- 2"MIC RO RAIL 6.5'SPLICE Q N 0 3 ' o' 0) }0 � ROOFMATERIAL NOT EXISTING FRAMING C 1L C)) U SHOWNFORCIARITY N — N T T WMIN /� Z Q (1)5/16"LAG BOLT EMBEDMENT `J 0 } WITH EPDM WASHER 5 01 O A- � L o_ (D U ATTAC WENT SPAC ING 00 Z / � PER TABLE ABO VE V (L) Q E SPACING *THIS DETAIL IS NOTMEANT TO BE FNG PERTIABLEABOVE O FRAMING DETAIL EXTERIOR WALL AN EXAC TREPRESENTATIO N 0 F ATTAC FM ENT DETAIL 0 0 SC ALE: 1/2"= 1'-0" FRAM ING O R PV MODULE LAYO Ui SC ALE: 1-1/2"= V-0" z z N RIDG E � ° NOES 0 u O r LAN DSC APE PO RTRAIT u a Sealed For PROICTID: Existing Roof & 936575 Attachm ent O dy PV DC SYSTEM SIZE: 6.560 kW DC PV AC SYSTEM SIZE: 5.200 kW AC REVISIONS: A• C4 l Al ---- ���` Q ---- l DRAWN BY: Brendan Fillmore 46056 PLOTDATE: fi IS7 �V May 2, 2024 ONAL F DRAW ING TITLE: Structural FO LLO WATTAC WENT SPAC ING IN TABLE ABO VE 5/2/2024 DRAWING NUMBER: EAVE *ATTAC HM ENT PATTERN SHOULD BE ATTAC FM ENT PATTERN STAGGERED UNLESS OTHERWISE P\ / /� �JJ SC ALE: 1/4"= F-0" NOTED IN ENGINEERING LETTER I V `"r Ll (1) 6AWGTHHN/THWN-2CUBLACK Ll (1) IOAWGTHHN/THWN-2CUBLACK Ll (2) IOAWGTHHN/THWN-2CUBLACK 3/4 INC H Ll (1) IOAWGTHHN/THWN-2CUBLACK 3/41NC Ll (1) 12AWGTHHN/THWN-2CUBLACK 5 L2 (1) 6AWGTHHN/THWN-2CURED L2 (1) 10AWGTHHN/THWN-2CURED 12 (2) IOAWGTHHN/THWN-2CURED EMT L2 (1) 10AWGTHHN/THWN-2CURED L2 (1) 12AWGTHHN/THWN-2CURED N (1) 6 AWG THHN/THWN-2 C U WHITE 4 N (1) IOAWGTHHN/THWN-2CUWHITE G (1) IOAWGTHHN/THWN-2CUGREEN L G (1) IOAWGTHHN/THWN-2CUGREEN G (1) 6AWGBARE,CU G (1) 10AWGTHHN/THWN-2CUGREEN *TYPE UFC ABLE MAY BE SUBSTITUTED FOR USE IN -TYPE NM(ROMEX)/UFC ABLE IS PERMITTED FORINTERIOR INCH EMT Exterior INCH EMT Exterior C O PDUIT WHERE NEC C O U:PERMITS 0 RATTIC RUNS AND SHALL BE USED WHEN NEC C 0 EE PERMITS ENPHASE Q-CABLE,2-WIRE,FREE AIR Exterior BLUE RAVEN SOLAR 1403 N 630 E O rem, Utah 84097 (800) 377-4480 BlueRavenSolar.com PRIMARY PV C O MITER BOX 0 15A 0—PRIMARY STRUC URE AC DISCO MJEC T O O(16)PV MOCULES OB &MIC RD INVERTERS SAFETY SW RC H (N)20A Op 10, Utility Meter (E)200A Main Service Panel 60A FUSIBLE PV ARRAY 1 PVCRCUTI 8 MOCULES ti ti N (D5 - P ❑ � ENVOY I2 (E)200A (N)20A I MEN CL N PVCRCUT2(EL) 8 MOCULES N 30A 3 2 L N Lf) FUSES nn _ ' � (EL) L "r J Q N (EL) N G —J ii O 5,' G ———— -------------------------- — ------------------- _0110— } I SUPPLY SIDE TAP 4 — (EL) I NEC 250.24(A) j N U BOND G RD UN DS (EL) ' AND NEUTRALS w, L N ' i Q z Q CL I •— U � o } E � � o () U ' U oo z G i J -C I N 0�------------------------------------J Q E UNDERG RD WD SERVIC E O 120/240 VAC,60 Hz —i— 9O 1 PHASE,3 WIRE — r O z GENERAL NOTES Z 0 Utility Meter Number:81182878 _ U O Interconnect using a supply side tap in MSP,interior POI. " U a LEGEND PRO JEC TID: (E) EXISTING (PV) PV BREAKER 936575 IN) NEW (FIB) FACTORY INSTALLED BREAKER (EL) EXISTING LOADS SPD SURGEPROTEC1VE DEVIC E PV DC SYSTEM SIZE: (RL) RELOCATEDLOADS MI MECHANICAL INTERLOCK 6.560 kW DC EQUPM ENT NOTES EQUPMENT DESC RPTIONS PV AC SYSTEM SIZE: 5.200 O FINAL CO NFIG URATIO N O F PV C RC UTS TO BE DEC DED BY INSTALLER.MUST C O M PY WITH MAX QA PV MODULE:Silfab Solar SIL-410 HC+410 W DC,UL 1703/UL 61730 C O M PIANT REVISIONS: kW AC MIC ROINVERTERS PER C RC UT AS LISTED 0ATTAC FED SPEC SHEET. ©MIC ID IN ENPHASE IQ8M-72-M-US,325 W AC(0.325 kW),1 PHASE,UL 1741 C O M BIANT S: N O ©ROOROPJUNC10NBOXEZSOLARJB-1.2JUNCTONBOX QA ---- QD JUNC10NBOX PVC 4X4JUNC10NBOX O ____0 PV C O MINER BO X ENPHASE IQ C O M ENER 4(X-IQ-AM 1-240-4) _ B OOSQUARE-DSAFTEYSWITCH60A,2P,240VAC,FUSIBLE(D222NRB) Q ---- © OO D ---- DRAW N BY: 0 0 Brendan Fillmore O0 - PLOTDATE: 6 AWG SO LID O IPER G EC TO BE IRREVERSIBLY SPLIC ED TO(E)G EC TO C O M PY WITH NEC © �., May 2,2024 0250.64(D)(1). O OTHER NOTES DRAWING TITLE: O9 GROUNDINGELECIRODE SYSTEM SHALL BEINACC0IDANCEWIIH NEC 250.53. 0 Electrical ,o ©-- 3-Line ® DRAWING NUMBER: 11 ALL INTERIORCONDUIT MUST BESCH80PVC. P O V� 12 ELEC 1RIC AL INFO RMATIO N PV BREAKER BAC DEED C ALC 11ATl0 NS DESIG N LO C 9I0 N UTILITY E LEC VIC AL SYSTEM NEC 705.12(B)—"120%RULE" AND TEMPERATURES BLUE RAVEN 1-Phase,3-Wire,60Hz, 1201240V (BUSBAR RATING*120%)-OC FD RATING=AVAILABLE BAC<FEED ^ I A n DATA SOURCE ASHRAE Weather Station Data NEW PV SYSTEM MAIN SERVICE SUBPANELI S UBPANEL2 STATE Washington 1403 N 630 E BUSBAR RATING 200A ----A ----A Phase,3-Wire,bOHz, 1201240V PANEL CfY ARLINGTON orem, Utah 84097 PANEL O C ID RATING 200A --A --A AC SYSTEM SIZE 5.2kW AC WEATHER STATION BO BNG FLD KING C O DC SYSTEM SIZE 6.56kW DC HIG H TEMP 2%AVG 29°C (800) 377-4480 PV MODULES AVAILABLE BAC(TEED(120%RULE) 40A ##A ##A EXTREME MINIMUM TEMP -7°C BlueRavenSolar.com Q UANTITY 16 PV BREAKER RATING 30A 30A 3 OA TYPE Silfab Solar SIL-410 HC+ *THESE C ALC U.ATIO NS ARE O N.Y APPLIC ABLE IF PV INTERC O MEC 10 NIS A WATTAGE 410W DC LO AD SIDE BREAKER.*PV BREAKER M UST BE RATED LESS THAN O REQ UAL TO AVAILABLE BAC IGEED FO R C O 0 C O M BANC E' MIC RO INVERTERS TYPE Enphase IQ8M-72-M-US OUTPUT C UtRENT 1.35A AC 0 NONINALVOUAGE 240VAC O U1PUT PO W It 325W AC co u WIRE SIZE SPEC FIC ATIO NS N N ® © ® 0 �� > 00 Q MINIMUM COIDUCTORAMPACFY I 3.5AAC 13.5AACI 3.5AAC2 7.08AAC2 7.08AAC- ---AAC- --AAC- —AAC- ---AAC- --AAC OD O C O HDUC 10 RMATERIAL C U C U C U C U C U t C0MUC10RTYPE THHN/THWN-2 THHN/THWN-2 HHN/THWN-2 HHN/THWN-2 HHN/THWN-2 -- — -- — -- COIDUCIORSIZE 12AWG 10AWG 10AWG 10AWG 6AWG C O MUC 10 RAM PAC FY 30A 40A 4 OA 4 OA 75A --A- —A- --A- --A- —A V () AMBIENT TEMPERATURE ADJUSTMENT FAC 10 R 1 1 1 1 1- C O IOUIT FILL ADJUSTM ENT FAC ID R 1 1 0 .8 1 1 — — -- — -- n' ADJUSTED C O IDUC 10 RAMPAC FY 30A 40A 3 2A 4 OA 75A ----A- ---A- ---A- ---A- ---A ��/+ Q IL W IRE RUN DISTANC E(FT) 52 5 0 2 0 5 1 0 — — -- — -- j= L� Z O } C PLC LLATEDVOITAGEDROP 0.52%0 1 .56%0 .22%0 .11%0 .09%0 %0 %0 %0 %0 % C U O PV C RC UT SPEC FIC ATIO NS Z CDz U � 0o Z U PRIMARY STRUC URE D ETAC FED STRUC URE -C C RC UT 1 CRC UT 2 r RC UT 3 RC UT 4 RC UT 5 RC UT 6 RC UT 7 RC UT 8I RC UT 1 C RC UT 2 C RC UT 3 RC UT 4 C RC UT 5 N NUMBER OFMODULES PER CRC UT 8 8 0 0 0 0 0 C 0 0 0 0 Q E RATED AC O UIPUT C UtRENT(I_) 10.8A 1 0.8A 0 OA 0 OA 0 OA 0 OA 0 OA 0 OA O.OA 0 OA 0 OA 0 OA 0 OA o MINIMUM AM PAC FY(1—x 125%) 13.5A 1 3.5A 0 OA 0 OA 0 OA 0 OA 0 OA 0 OA O.OA 0 OA 0 OA 0 OA 0 OA -E O VERC U2RENT PRO 1EC 10 N RATING 20A 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA 2 OA o C O M 9dED AC O U1PUT C U2RENT(C..) 21.6A O.OA z C MINIMUM AM PAC FY(C.,x x 125%) 27.OA O.OA z -4 N C O MBJED PV BREAKER RATING 30AA OAA 0 U 0 r TO TA L J u a VO [TAG E DRO P PROJECTID: VOl7 P 936575 WIRE TAG#1 0.52%0.52% WIRE TAG#2 0.56% PV DC SYSTEM SIZE: WIRE TAG#3 0.22% 6.560 kW DC WIRE TAG#4 0.11% WIRE TAG#5 0.09% PV AC SYSTEM SIZE: WIRE TAG#6 0% 5.200 kW AC TOTAL 1.500000% REVISIONS: A ---- A ---- A ---- DRAW N BY: Brendan Fillmore PLOT DATE: May 2, 2024 DRAWING TITLE: Electrical C dculations DRAWING NUMBER: P V 6 WARNING LABELS BLUE RAVEN SOIAR UTILITY METER MAIN SERVIC EPANEL AC DISCO MIEC T 1403 N 630 E Orem, Utah 84097 (800) 377-4480 •TO • LTAIC SYSTEM BlueRavenSolar.com DISCOA AC RATED AC 0 UTPUT CURRENT 21.E A NO MINAL 0 FERATING AC VO LTAG E 240V OWARNING ELECTRIC SHO OC HAZARD TERM NALS 0 NTHE LINE AND } LOAD SIDES MAY BE ENERG QED .0 IN THE 0 PEN PO STIO A PVCOMINERBOX N N SO lAR PV SYSTEM EQ UPPED CD WITH RAPID SHUTDO W N TURN RAPID SHUTDOW FO' •LAR PV SYSTEMTO�O LTAIC SYSTEM$W fiCH TO THE "O FF"PO STIO NTO SHUTDDWNPv 'TEM CO M®NER PANEL 0) } AND REDUCE SHOA LLI 1 WARNING INT THEHE A ARRRAYY.. N U AUTHO RZED O PERSO NVEL O NLY 3 Q DO NO TADD LO FDS re Q Z IL NO DC WIRES PRESENT U O RAPID SHUTDO W IN 5 .� TEST NO TREQ URED L 01 CD 'n U 0o Z U I N E O zO Z N O U O r U Q PRO.EC TID: A CAUTIO N 936575 M LLTIPLE SO URCES O FPO W ER PV DC SYSTEM SIZE: PO W IR TO THIS BUILDING IS ALSO SUPPLIED FRO MA RO O FM O WTED 6.560 kW DC SO IAR ARRAY.PV DISCO NJECT IS LO CATED WITHIN 10 FT AND LINE PV AC SYSTEM SIZE: O FSIG FR O FUTILITY M ETER. 5.200 kW A REVISIONS: A ---- L B ---- OWARNING DUAL PO W IR SUPPLY A SO LRCES:UTILITY G RD AND PV SO LAIR ELECTRIC SYSTEM DRAW N BY: Brendan Fillmore PLOT DATE: • May 2, 2024 IN CASE O FEMff2G BVCY, DRAW ING TITLE: PLEASE CO NfACT: BLUE RAVEN SO LAR Warning (800) 377-4480 Labels DRAWING NUMBER: PV7 ••• ELECTRICAL SPECIFICATIONS 4 10 ••••• Test Conditions S TC N OCT BLUE RAVEN 06 SILFAB PRIME S I L FA B • p 4 Maxim urn poweP voltage(Vpm aO V 3 8.9933 6.24 SOLAR SO L A R Maxim Lyn power current(Ipm a() A 1 0.52 8 .43 SIL-410 HC+ Open circuit voltage(Voc) V 4 5.59 4 2.76 Short circuit current(Isc) A 1 1.15 8 .99 Modu le efficiency2% 0.70/o 1 9.3% Maxim urn system voltage(VDC) V 1000 Series fuse rating A 20 p Power Tolerance W 0to+10 Measurem ett cond itions:STC 1000 W/n'•AM 1.5•Tern perature 25°C•NOCT 800 W,In'•AM 1.5•Measu rem ett u ncertai my 5 3% Sun sim tlator calibration reference m odules from Fraunhofer Institute.Electrical characteristics m ay vary by±5%and power by 0 to+10W. M ECHANICAL PROPERTIES/COM FONENTS M Moduleweight 2 1.3kg±0.2kg 4 711bs±0.41bs Dim(nsions(HxLx D) 1 914 m mx 1036 m mx 35 in m -5.3 in x 40.8 in x 1.37 in Maxim urn surface load(wind/snow)* 5 400 Pa rear load/5400 Pa front load 1 12.81b/ft2 rear load/112.8lb/ft2 front load Hail impact resistance o 25In mat 83 km/h o pin at 51.6m ph Cells 132 Half cells-Si m mo PERC 132 Half cells-Si m mo PERC 9 busbar-83 x 166 m m 9 busbar-3.26 x 6.53 in Glass 3.2 m mhigh transm ttance,tem pered, 0.126 in high transm stance,tem pered, anti-reflective coating anti-reflective coating Cables and connectors(refer to installation m atual) 1 350 m m o 5.7 m m)AC4 from Staubli 5 3 in,o 0.22 in(12AW Q,MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,m dti-layer dielectric film, fluorine-free PV backsheet Fram a Alodized Alum hum(Black) Bypass diodes 3 diodes-30SQ045T(45V m a(DC blocking voltage,30A m a(forward rectified current) Junction Box U L 3730 Certified,IEC 62790 Certified,IP68 rated TEM PERATURE RATINGS WARRANTIES Temperature Coefficient Isc + 0.064%fc Module product workm alship warranty 2 5 years** Temperature Coefficient Voc - 0.28%PC Linear power perform alceguarantee 3 0years Tern perature Coefficient Pm a( - 0.36%PC >_97.1%end 1st yyr NOCT(±2°C) 4 5°C >_91.6%end 12th yr >_85.1%end 25th yr Operating temperature- 40/+85°C >_82.6%end 30th yr CERTIFICATIONS SHIPPING SPECS UL 61215-1:2017 Ed.1,UL 61215-2:2017 Ed.1,UL 61730-1:2017 Ed.1,UL 61730-2:2017 Ed.1,CSA C22.2#61730-1:2019 Ed.2,CSA C22.2#61730-2:2019 Ed.2,IEC 61215-1:2016 Modules Per Pallet: 2 6 or 26(California) Product Ed.1,IEC 61215-2:2016 Ed.1,IEC 61730-1:2016 Ed.2,IEC 61730-2:2016 Ed.2,IEC 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Am m mlia Corrosion),CEC Listing,UL Pallets Per Truck 3 2 or 30(California) Fire Rating:Type 2 Factory I S09001:2015 Modules Per Truck 8 32 or 780(California) * A W aming.Read the Safety and Installation Manual for m cunting specifications and before handling,installing and operating In odules. ** 1 2 year extendable to 25 years subject to registration and conditions outlined under"W xranty"at silfabsolar.com. PAN files generated from 3rd party perform ante data are available for download at:silfabsolar.com/dow doads. 75.3"[1914m art] I _ E v E 12.1"[307m m] 51.2[1300m m] 2.1"[307m In] RELIABLE ENERGY SILFAB SOLAR INC. DIR EC T FRO MTHESOURCE venting Hole(x4) (D 800 Cornwall Ave 0.5" Bellingham W A98225 USA Designed to outperform . r.«•r•Me [12mm] 7+1360.569.4733 2023 • info@difabsolar.com LA Dependable, durable, high-perform ante o E 1770 Po SDrive M nu•wus+•�'uuo• E E 1770 Port Drive solar panels engineered for North ( - E 11 Burlington WA98233 USA m 1.4" 35m m o� to E °� M o n °� o T+1360.569.4733 American homeowners. N a X of o 240 Courtneypark Drive East 3 E o Mississauga ON L5T 2Y3 Canada S I L F A B D LA R CO M e r+1905.255.2501 a m 0.06" 53.15" F+1905.696.0267 ��[1.5mm] L9 3 Caableble Length h f.- Q Silfab-SIL-410-HC+-20230726 o0 No reproduction ofany kind is allowed without H�Zrainage Hole(x8) permission.Data and inform loon is subject to I�� o 2022. ilfab olar-i anotice ed trabSolar of I � Fraunhofer I_�--� U B B Silfab Silfab solar•isa registered t2dem ark of Silfab solar inc. DRAWING NUMBER: r, i L,` • ist •C'.,LO pvv.+des to]nr•o 5o1er Inc, � �2,4"[60m m] 8"[200m m] SS EN PHAS E m IQ 8VI and IQ 84 M broinverters Nor- BLUE RAVEN SOLAR INPUT 1ATA(DCI U NITS A: C on m mlly used m odule pairings' W 280.480 95-500 fill M odule com� patibility To m eat com patibility,PV m odules m tst be w thin the follow hg m ecim un input DC voltage and m adrn un m odule I .• 14 M odule com patibility can be checked at https://enphase.com Anstallers/m broinverters/calculator x M FPT voltage range v 30-4 2-45 Operating range V 16-58 M him un iM acim un start voltage V 22/58 J J J M adm un input DC voltage V 60 i M adm un continuous input DC current A 12 M ecim un input DC short-circuit current A 25 M adm un m odule I A 20 O%ervoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 ungrounded array;no additional DC side protection required;AC side protection requires m a(20 A per branch circuit OUTPUT 1' 1: Peak output power VA S.`p 66 M atim un continuous output power VA ??.`_: 49 Q N and IQ 8% M broinverters Nom hal grid voltage(L-L) V 240,split-phase(L-L),180' M him un and M adm un grid voltage2 v 211-264 O u-newest IQ 8M broinverters are the industry's first m brogrid-form hg,software- M atim un continuous output current A s> .45 defined m broinverters w th split-phase power conversion capability to convert DC Easy to install Lightweight and com ct w th plug- is Nom hal frequency Hz 60 power to AC power effi dently.The brain of the sem bonductor-based m broinverterPa P S- and-play connectors Extended frequency range Hz 47-68 is our proprietary application-specific integrated circuit(ASIC)w fich enables the m broinverter too operate in rid-tied or off-grid m odes.This chi Is built using Power line com m Imication(PLC) AC short-circuit fault current over P 9 9 P� 9 between com ponents Arms 2 advanced 55-nm technology w th high-speed digital logic and has superfast Faster installation w th sim lie two- three cycles response tim es to changing loads and grid events,alleviating constraints on battery wre cabling M ecim un units per 20 A(L-L)branch 11 sizing for hom eenergy system s circuit3 High productivity and reliability Total harm uric distortion % < 5 Produce power even w han the grid is dow rl O xervoltage class AC port III Enphase M e-e than one m Ilion cum dative AC port backfeed current mA 30 hours of testing 5 Power factor setting 1.0 C lass II double-insulated enclosure mited O ltim eed for the latest high- G id-tied power factor(adjustable) 0 .85leading...0.85 lagging L warranty -A powered PV m edules peak effi dency / 97.$ 7.7 Part of the Enphase Energy System,IQ 8Series IQ 85eries M broinverters redefine reliability M i¢rogrid-form ng C EC weighted effi dency % 97.5 7 M broinverters integrate w th the IQ Battery, standards w th m cre than one m Ilion IQ G ateway,and the Enphase App m mitoring and cum dative hours of power-on testing, C on plies w th the latest advanced Nighttim epower consum ption mw 21 2 analysis software. enabling an industry-leading lim ted warranty grid support** DATA of up to 25 years. Rem cte autom atic updates for the latest grid requirem Ents Am bent tem perature range - 40°C to 60°C(-40°F to 140T) C mfigurable to support a w de Relative hum dity range 4%to 100%(condensing) range of grid profiles Meets CA Rule 21(UL 1741-SA)and IEEE DC connector type Staubli M C 4 1547:2018(UL 1741-SB 3'd Ed.) Dim ensions(H•W•D) 2 12 m m(8.3")•175 m m(6.9")•30.2 m m0.2") CERTIFIED NOTE: Weight 1.1 kg(2.43lbs) • IQ 8M broinverters cannot be m aced together w th C eoling Natural convection—no fans C rnnect PV modules quickly and easily to the IQ 8Series M broinverters are UL Listed as previous generations of Enphase m broinverters IQ 8Series M broinverters that have integrated PV rapid shutdow nequipm Elt and conform 007 Series,IQ 6Series,and so on)in the sam a Approved for wet locations Yes M C 4connectors. w th various regulations w 1,3n installed system. according to the m Eiufacturer's instructions. Pollution degree PD3 • IQ G 3eway is required to change the default grid I profile at thetim eof installation to m eat the local Enclosure C ass II double-insulated,corrosion-resistant polymeric enclosure Authority Having Jurisdiction(AHJ)requirem arts. Environm ertal category/UV exposure rating N EM AType 6/outdoor *M e:ts UL 1741 only w h:n installed w th IQ System C mtroller 2. **IQ EM and IQ8A support split-phase,240 V installations only. (D No enforced DC,AC ratio. (2)Nom hal voltage range can be extended beyond nom hal if required by the utility. DRAWING NUMBER: (3)Lim is m ar vary.Refer to local requirem Efts to define the num bar of m broinverters per branch in your area. IQ 8M A-M C 4DSH-00205-2.0-EN-US-2023-11-03 10 EM A-M C 4DSH-00205-2.0-EN-US-2023-11-03 SS Nor- Data Sheet Enphase Q Cable Accessories BLUE RAVEN Enphase Q Cable Accessories SOLAR REGION:Americas CO N W Cr0 RSPECIFICATIO N S Certification U L3003(raw cable),UL 9703(cable assemblies),DG cable Flametest rating F T4 Compliance R oHS,OIL RES I,CE,UV Resistant,combined UL for Canada and United States Conductor type T HHN/THW N 2 dry/w Et Enphase The Enphase Q Cable'm and accessories are part of Disconnecting means T he AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ System'm.These disconnect required by NEC 690. QCable Accessories accessories provide Sim plicity, reliability,and faster Q CA BLE TYPES/0 RDERING 0 PTIO N S installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing P V Module Orientation Connector Count per Box Q-12-10-240 12 AW G/277 VAC 1.3 m(4.2 ft) Portrait 2 40 Q-12-17-240 12 AW G/277 VAC 2 .0 m(6.5 ft) L andscape(60-cell) 2 40 Q-12-20-200 12 AW G/277 VAC 2 .3 m(7.5 ft) L andscape(72-cell) 2 00 EN PHA SE Q CA BLE ACCESSO RIES Name Model Number D escription Raw Q Cable Q-12-RAW-300 3 00 meters of 12 AW G cable w th no connectors Enphase Q Cable Field-w ireable connector(male) Q-CONN IOM M ake connections from any open connector • Tw ow�e,double-insulated Enphase Q Cable Field-w�eable connector(female) Q-CONN 10F Make connections from any Q Cable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 U sed to fasten cabling to the racking or to secure looped cabling Enphase cable • New cable numbering and plug and play Disconnect tool Q-DISC-10 D isconnect tool for Q Cable connectors,DC connectors,and AC m odule m ount connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEAL-10 0 ne needed to cover each unused connector on the cabling w'e management • Link connectors eliminate cable w mte Term inator Q-TERM-10 T erm inator cap for unused cable ends Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV m odule using MC4 connectors to IQ m icros w th EN4(TE PV4-S SOLARLOK). 150m mi5.9"to MC4. Enphase EN4 non-term hated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non-terminated cable.150m m)5.9" Field-W ireable Connectors Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use w th split cell modules or PV modules w th short DC cable.600mm23.6" Easily connect Q cables on the roof w thout Replacement DC Adaptor(MC4) Q-DCC-2 D C adaptor to MC4(max voltage 100 VDC) com plex w ping Replacement DC Adaptor UTX ( ) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable w thin 1.Qualified per UL subject 9703. branch limits Available in m ale and fem ale connector types TERMINATOR SEA LING CA P5 Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCO N N ST TO 0 L CA BLE CLIP Plan to use at least one per Used to fasten cabling to the racking installation,sold in packs of ten or to secure looped cabling,sold in (Q-DISC-10) packs of one hundred(Q-CLIP-100) To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ To learn more about Enphase offerings,visit en hase.com E N P H A S E. 2020 06 bother trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. �1 E N P H A S E p 9 p DRAWING NUMBER: SS Nor- IQ Combiner 4/4C BLUE RAVEN Data Sheet SOLAR Enphase Networking MODEL IN UMBER 10 CoMbIll 4 O�McItda IQ Com biner4C IQ Com bner4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12-20 0.5%) X_IQ-AM1-240-4C and consumption monitoring(±2.5%).Includes Mobile Connect cellular modem(CELLM ODEM-M 1-06-SP-05),a plug-and-play The IQ Com biner 4/4C w th IQ Gatew ay and X2-IQ-AM 1-240-4C(IEEE 1547:2018) industrial-grade cell modern for systernsup to 60 m icroinverters.(Available in the US,Canada,M exico,Puerto Rico,and the IQ Combiner 4/4C US Virgin Islands,w here there is adequate cellular service in the installation area.)Includes a silver solar shield to match the integrated LTE-M 1 cell modem (included IQ Battery and IQ System Controller and to deflect heat. only w th IQ Combiner 4C) consolidates ACCESSORIES A NO REPLACEM EN TPA RTS not included,order separately) Supported microinverters I Q6,IQ7, and IQ8.(Do not m bc IQ6/7 M icroinverters w th IQ8) interconnection equipment into a single Comm unications Kit enclosure. It streamlines IQ M icroinverters and COMMSCELLMODEM-M1-06 Includes COM M S-KIT-01 and CELLM ODEM-M 1-06-SP-05 w th 5-year Sprint data plan CELLM ODEM-M 1-06-SP-05 4G based LTE-M 1 cellular m odem w th 5-year Sprint data plan storage installations by providing a consistent, CELLM ODEM-M 1-06-AT-05 4G based LTE-M 1 cellular m odem w th 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. El -A pre-w red solution for residential applications. BRK-10A-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 It offers up to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240VB Circuit breaker,2 pole,15A,Eaton BR215B w th hold dow nkit support Eaton BR series busbar assembly. BRK-20A-2P-240VB Circuit breaker,2 pole,20A,Eaton BR220B w th hold dow nkit support XA-SOLARSHIELD-ES R eplacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 A ccessory receptacle for Power Line Carrier in IQ Com twiner 4/4C(required for EPLC-011) X-IQ-NA-HD-125A H old-dow nkit for Eaton circuit breaker w th screw s Consumption monitoring CT A pair of 200A split core current transformers Sm art (CT-200-SPLIT/CT-200-CLAM P) ELECTRICAL SPECIFICATION S Includes IQ Gatew aj for com m unication and control Rating C ontinuous duty Includes Mobile Connect cellular modem (CELLM ODEM-M 1-06-SP-05),included only w th System voltage 1 20/240VAC,60 Hz IQ Com biner 4C Eaton BR series busbar rating 1 25A Includes solar shield to match Enphase IQ Battery M ac continuous current rating 6 5A aesthetics and deflect heat Mac.continuous current rating(input from PV/storage) 6 4A Supports WimlFi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 9 OA Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) U p to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Provides production metering and consurn ption M ax.total branch circuit breaker rating(input) 8 OA of distributed generation/95A w th IQ Gatew&I breaker included m onitoring IQ Gatew a'breaker 1 OA or 15A rating GE/Siemens/Eaton included Production metering CT 2 OOA solid core pre-installed and w red to IQ Gatew aj Sim ple M ECH A NCAL DATA X-IQ Atli 1 211.111 4C M ounts on single stud w th centered brackets Dimensions(WxHxD) 3 7.5cm x49.5cm x 16-8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5cm(21.06 in)wth mounting brackets. •X2-IQ-AM 1-240-4C(IEEE 1547: Supports bottom,back and side conduit entry Weight 7 .5 kg(116.5 lbs) Allow sup to four 2-pole branch circuits for 240VAC Am Icient temperature range- 400C to+460C(-40OF to 1150F) plug-in breakers(not included) Cooling N atural convection,plus heat shield 80A total PV or storage branch circuits Enclosure environmental rating 0 utdoor,NRTL-certified,NEMAtype 3R,polycarbonate construction Wire sizes 20A to 50A breaker inputs:14 to 4 AWGcopper conductors 60A breaker branch input:4 to 1/0 AWGcopper conductors Reliable Main lug com blined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Durable NRTL-certified NEMAtype 3R enclosure AM ajs follow local code requirements for conductor sizing. Five-year lim ited w arranty Altitude U p to 3,000 meters(9,842 feet) Two years labor reimbursement program coverage INTERNET CON NECTION OPTIONS included for both the IQ Combiner SKU's Integrated Wi-Fi I EEE 802.11b/g/n X-IQ-AMl-240-4 JIL listed Cellular C ELLMODEM-M 1-06-SP-05,CELLMODEM-Ml-06-AT-05(4G based LTL-M1 cellular modem) Note that an Mobile Connect X2-IQ-AM 1-240-4 and X2-IQ-AM 1-240-4C com ply w th cellular modem is required for all Enphase Energy System installations. X2-IQ-AM 1-240-4(IEEE 1547:2018) IEEE 1547:2018(UL 1741-SB,3r'Ed.) Ethernet 0 ptional,IEEE 802.3,Cat5E(or Cat6)UTP Ethernet cable (not included) CO IMPLIA N(E O Compliance,IQ Combiner C A Rule 21(U L 1741-SA) IEEE 1547:2018-UL 1741-SB,3r'Ed.(X2-IQ-AM 1-240-4 and X2-IQ-AM 1-240-4C) CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) LISTED ENPHASE. com Consumption metering:accuracy class 2.5 To learn m are about Enphase offerings,visit enphase.com pliance,IQ Gatewai U L 60601-1/CANCSA 22.2 No.61010-1 IQ-C-4-4C-DS-0103-EN-US-12-29-2022 2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change. IQ-C-4-4C-DS-01 03-EN-US-1 2-29-2022 DRAWING NUMBER: SS D Nor- BLUE RAVEN Data Sheet Enphase Networking 03 N.Research Enphase IQ Envoy 140iem,LIT 84097vay 800.377.4480 MODEL N U M HRS WWWBLUERAVENSOLAR.COM Enphase IQ EnVoyTM Enphase IQ Envoy com m unications gateway with integrated revenue grade PV CO N=IDENTIAL-THE INFO Rv1ATIO N ENV-IQ-AM 1-240 production HEREIN CO NfAINED SHALL NO TBE metering(ANSI C12.20+/-0.5%)and optional consumption monitoring(+/-2.5%). USED FO RTHE BENEFIT 0 FANYO W Includes EXCEPT BLUE RAVEN SO LAR NO R Enphase IQ Envoy M SHALL ITBETO0-11 gS0UrSI LEOR The Enphase IQ Envoy com m Lnications gateway one 200A continuous rated production CT(current transformer). IN PART TO CLO DISCLOSED O IN WHO E delivers solar production and energy consumption ACCESORIES(OrderSeperately) RECIPIENTS 0 FIG ANIZATIONEXCEPT IN CO MIECTIO NWITH THE SALE AND Enphase Mobile Connect' Plug and play industrial grade cellular m odem with data plan for system s up to 60 USE 0 FTHE RESPECTIVE EO UPM ENT, data to Enphase Enlighten'M monitoring and analysis CELLM ODEM-M 1(4G based LTE-M/5-year data plan) m Icroinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin WITHO Ur THE WRITTEN PERM ISSIO N software for comprehensive,rem ote m aintenance and CELLM ODEM-M 1-B(4G-based LTE-M 1/5-year data plan) Islands,where there is adequate cellular service in the installation area.) O FBLUE RAVEN SO LAR LLC. Consumption Monitoring CT Split-core consum ption CTs enable whole horn emetering. management of the Enphase IQ System. CT-200-SPLIT Ensemble Comm unications Kit Installed at the IQ Envoy.For com m unications with Enphase Encharge'"'storage NABCE P COM M SKIT-01 and Enphase Enpower"smart switch.Includes USB cable for connection to IQ CERTIFIED W ith integrated revenue grade production metering Envoy or Enphase IQ Com biner'"and allows wireless communication with Encharge and Enpower. and optional consumption m onitoring, Envoy IQ is the POWER REQUIREMENTS PV INSTALLATIO N PRO FESSIO N4L platform for total energy m anagem ent and integrates Power requirements 120/240 VAC split-phase. Scott G uney Max 20 A overcurrent protection required. #PV-011719-015866 with the Enphase Ensem bleTmand the Enphase IQ Typical Power Consumption 5W BatteryTM. CA PACITY CO WRACTO R Numberofmicroinverterspolled U pto600 BRS FIELD O PS 385-498-6700 MECH ANICAL DATA Dimensions(WxHxD) 2 1.3 x 12.6 x 4.5 cm(8.4"x 5"x 1.8") Sm art Weight 17.6 oz(498 g) Enables w Eb-based monitoring Ambient temperature range - 40°to 65°C(-40°to 149'F) and control -40°to 46°C(-40°to 115'F)if installed in an enclosure�ENPHASIIE Bidirectional com m unications for Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMAtype 3R enclosure. remote upgrades Altitude T o 2000 meters(6,560 feet) •Supports power export lim icing and Production CT- Lim iced to 200A of continuous current/250A OCPD—72kW AC zeroexport applications Internal aperture measures 19.36m mto support 250M CM THWN conductors(max) UL2808 certified for revenue grade metering Consumption CT- For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84"x 0.96"(21.33mmx 24.38mm)to support Simple 3/0 THWN conductor Easy system configuration using UL2808 certified,for use at service entrance for services up to 250Vac • Enphase Installer Toolkit"mobile app INTERN ET CO N N ETIO NOPTIO N S Flexible netw eking w th W i-Fi, Integrated Wi-Fi 802.11 b/g/n Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLM ODEM-M 1(4G)or CELLM ODEM-M 1-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable CO MPLIANCE Compliance UL 61010-1 Designed for installation indoors CAN/CSA C22.2 No.61010-1 or outdoors 47 CFR,Part 15,Class B,ICES 003 DRAWING BY: Five-year w aranty IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 Metering:ANSI C12.20 accuracy class 0.5(PV production only) PLO TDATE: 0 PRO JECT NUM L£R: CERTIFIED E N P H AS E. To learn more about Enphase offerings,visit enphase.com E N P H AS E SHEET NAM E To learn m ore about Enphase offerings,visit enphase.com �./ ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,and other trademarks or service names are the trade- SPEC SHEET marks of Enphase Energy,Inc.Data subject to change.06-30-2021 REVISIO N PAG ENUM EER: ---- SS Nor- BLUE RAVEN 1403 N.Research Way O iem,UT 84097 800.377.4480 W W W BLU ERAVENSOLAR.CO M 6.63 .16 DIA WIRING DIAGRAMS H REIN CO NTAINED SHALLCO W DENTIAL-THE INFO�NO TBE 168 USED FO RTHE BENEFIT O FANYO NE 31 DIA FUSIBLE EXCEPT BLUE RAVEN SO LAR NO R SHALL IT BE DISCLOSED IN WHO LE O R + 8 IN PART TO O IHERS O UrSIDE .50 RECIPIENTS O R3 ANIZATIO N EXCEPT 13 IN CO MIECTIO NWITH THE SALE AND USE O FTHE RESPECTIVE EQ UPM ENT, 5 / WITHO Ur THE WRITTEN PERM ISSIO N A B O FBLUE RAVEN SO LAR LLC. NABCEP O TERMINAL LUGS CERTIFIED AMPERES MAX. W 1 RE MIN. WIRE TYPE PV INSTALLATIO N 14.88 1 1 .24 60 #3 AWG #14 AWG CU OR AL PRO FESSIO NAL 378 285 0 Scott G irney KNOCKOUTS #PV-011719-015866 SYMBOL CONDUIT SIZE DIAMETER CO WRACTO R A,B,C IN I MM IN MM BRS FIELD O FS KNOCKOUTS A,B,C A .50 13 .88 22 KNOCKOUTS B 7s 19 1.13 29 385-498-6700 C 1.00 25 1.38 �45 35 D 1.25 32 1.75 64-1 L 42 3.76 L 4.87:1 .31 DIA 96 124 8 7.45 (2 HOLES) 189 NEMA TYPE 3R A,B,C,D KNOCKOUTS r� ^,�) A KNOCKOUTS DUAL DIMENSIONS: INCHES MILLIMETERS .28 DIA KNOCKOUT A,B,C HORSEPOWER RATINGS 7 KNOCKOUTS CATALOG WIRING AMPERE 240VAC NOTES: NUMBER VOLTAGE RATINGS DIAG. RATING FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITED OVER CLEANED PHOSPHATIZED STEEL STD. MAX. UL LISTED - FILE E-2875 1 0 3 0 1 3 0 DRAWING BY: ALL NEUTRALS - INSULATED GROUNDABLE SUITABLE FOR USE AS SERVICE EQUIPMENT D222NRB 240VAC A 60 3 7.50• 10 15• SHORT CIRCUIT RATINGS: D322NRB 240VAC B 60 3 X 7.50 10 15 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES PLO TDATE: 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES TOP ON NEMA 3R ENCLOSURES HAVE PROVISIONS FOR MAXIMIM 2.50 BOLT-ON HUBS. WHEN MOUNTING THESE SWITCHES, ALLOW 3.00 IN / 76 MM MIN. CLEARANCE BETWEEN ENCLOSURES FOR OPENING OF SIDE HINGED DOOR. GENERAL DUTY SAFETY SWITCHES SQUARE O COMPANY X USE OUTER SWITCHING POLES VISIBLE BLADE TYPEmo PRO ECT NUM BIER: •FOR CORNER GROUNDED DELTA SYSTEMS ONLY. 60 AMPERE LUGS SUITABLE FOR 60°C OR 75°C CONDUCTORS. ENCLOSURE - NEMA TYPE 3R RAINPROOF NOG. 863 SHEET NAM E JUNE 2000 REF DWG a1863 SPEC SHEET REVISIO N PAG ENUM EER: ---- SS JB- 1 . 2 EZf SOLAR PHONE: 385-202-4150 EZf SOLAR Specification Sheet mahg solar simple. WWW.EZSOLARPRODUCTS.COM BLUE RAVEN making solar simple, PV Junction Box for Corn position/Asp halt Shingle Roofs 1403 N.Research Way A. System Specifications and Ratings Oem,UT84097 Y P g ITEM N0. PART NUMBER D ESCRIPTION 0 TY slzE owG.No. R Ev 800.377.4480 POLYCARBONATE WWWBLUERAVENSOLAR.CO M • AA ximum Voltage: 1,000 Volts 1 1 JB-12BODY CONFIDENTIAL-THE INFO Rv1ATION WITH UV INHIBITORS SCALE:1:2 EIGHT:1.45 LBS HEFT 1 GF 3 HEREIN CO NfAINED SHALL NO TEE • M ximum Current: 80 Amps USED FO RTHE BENEFIT 0 FANYO NE EXCEPT BLUE RAVEN• JB-1.2 LID POLYCARBONATE 1 SHALL IT BE DISCL.O SEDSINO WHO LE O R Allowable Wire: 14 AWG—6 AWG 2 q p WITH UV INHIBITORS TORQUE SPECIFICATION: 15-20 LBS IN PART TOOTHERS O UFSIDE EXCEPT • Spacing: Please mantain a spacing of at least '/2"between uninsulated live parts and fittings for IN COINNECTONNWITHTHEESA ELAND conduit, arm cred cable, and uninsulated live parts of opposite polarity. #10 X 1-114"PHILLIPS UL STANDARD 1741, USE 0 FTHE RESPECTIVE EQ UPM ENT, 3 6 CERTIFICATION: W ITHO UT THE WRITTEN PERM ISSIO N • Enclosure Rating: Type 3R PAN HEAD SCREW NEMA 311 0 FBLUE RAVEN SO LAR LLC. • Roof Slope Range: 2.5 — 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS NABCEP • AA x Side Wall Fitting Size: 1" PAN HEAD SCREW • AA x Floor Pass-Through Fitting Size: 1 1 CERTIFIED • Ambient O perating Conditions: (-35°C) - (+75°C) PV INSTALLATIO N • C ompliance: PRO cFESSIO N4L - JB-1.2: UL1741 #PV-011719-015866 -Approved wire connectors: m List conform to UL1741 CO NFRACTO R - --- --- --- --- --- --- --- • System M erking: Interek Symbol and File#5019942 i i '�� BRS FIELD O F5 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion \� 385-498-6700 between components, components that are found to be affected are to be replaced im m etiately. Table 1:Typical Wire Site,Torque loads and Ratings 1 Conductor 2 Conductor Torque Type NM Inch Lbe Voltage Curren ASO ZS6 terminal block 10-24 awg 16.24aw Sol/Str 0.5-0.7 6.2.8,85 600V 30amp ABB ZS10 terminal block 6.24 awg 12.20 awil Sol/Str 1.0.1.6 8.8S-14.16 600V 40 amp ABB Z516 terminal bock 4.24aw 10.20aw Sol/Str 1.6.2.4 14.6.21.24 600V 60 amp 279.68mm] [276.30mm] ABB M6/8 terminal black 8.22 awS Sol/Str. .08.1 8.85 600V 50 amp 11.01 in 10.88in F11 Ideal 452 Red WING NUT Wire 8 18awg Sol/Str Self Torque Self Torque 600V Connector Ideal 451 Yellow WING-NUT i SOLAR Wire Connector 30 18 awg Sol/Str Self Torque Self Torque 600V Ideal,In-Sure Push-In 10.14 a" Sol/Str Self Torque Self Torque 600V Connector Part#39 1 J6-1.2 I I WAGO,2204-1201 10-20 awg 16-24 awg Sol/Str Self Torque Self Torque 600V 30 amp WAGO,221612 10-20 awg 10-24 awg Sol/Str Self Torque Self Torque 600V 30 amp DottieDRC75 6-12awg Sol/Str Snap-In Snap-In 46 awgSol/Str 45 ESP NG 53 2000V 10-14 awlt Sol/Str 35 } ESP MG-717 46 awg Sol/Str 45 2000V ( "' 10-14 awg Soi/Str 35 DRAWING BY: Brumall4.5,3 46 awg Soi/Str 4S 2000V 10-14 awg Soi/Str 35 183.06mm_ _ 72.53mm i 7.21 in 2.86in PLO TDATE: Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) 265.18mm Wire site,AWG or Wires per terminal(pole) 10.44in 1 2 3 4 or More PRO ECT NUM BER: kcrnil mm2 mm inch mm (inch) mm (inch) mm (inch) 14-10 (2.1-S.3) Not specified - - 8 (8.4) 38,1 (1.1/2) SHEET NAME 6 (13.3) 1 $0.8 (2) SPEC SHEET REVISIO N PAG ENUM BER: EZf SOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM PROPRIETARY AND CONFIDENTIAL:THE INFORM/FION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTY OFEZSOLAR. ———— SS ANY REPRODUCTION IN PARTOR AS A W HDLE W IFHOUTTHE W RTTEN PERM I SION OF EZ SOLAR IS PROHIBITED. BLUE RAVEN Nor- Rigid Nonmetallic Conduit I Boxes S V` carion• 1403 i9 Research Way M cided Nonmetallic Junction Boxes Except�re noted O 00 77 8480 LISTED by E42728 VIEW SHOWN LESS WWWBLUERAVENSOLAR.COM 6P Rated COVER FOR CLARITY 3.10 CO N=IDENTIAL-THE INFO Rvl ATIO N (941 0.20 HEREIN CO NTAINED SHALL NO TEE USED FO RTHE BENEFIT 0 FANYO NE It's another first from Carlon°-the first nonmetallic _ (5 I EXCEPT BLUE RAVEN SO LAR NO R SHALL IT BE DISCLO SED IN WHO LE O R junction boxes UL Listed with a NEM A6P rating per IN PART TO OTHERS O UTSIDE RECIPIENTS O R3 ANIZATIO N EXCEPT Section 314.29,Exception Of the National Electrical Code. IN CO NNECTIO NWITH THE SALE AND USE 0 FTHE RESPECTIVE EQ UPM ENT, M alufactured from PVC or PPO thermoplastic molding 3.70 W ITHO Ur THE WRITTEN PERM LSSIO N compound and featuring foam-in-place gasketed lids (941 50 O FBLUE RAVEN SO LAR LLC. attached with stainless steel screws,these rugged 1541 1 12 71 enclosures offer all the corrosion resistance and physical rNABCEP� properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor L CERTIFIED _ use,primarily to provide a degree of protection against PV INSTALLATIO N contact with enclosed equipment,falling dirt,hose- - PRO FESSIO MIL Scott G(rney directed water,entry of water during prolonged . B #PV-011719-015866 submersion at a limited depth,and external ice formation. CO NfRACTO R BRS FIELD O F5 TD� 385-498-6700 w •All Carlon Junction Boxes I r are UL Listed and maintain 0 0_ o AT T]T ——— a minimum of a NEM AType 4/4x Rating. CO � o I • Parts numbers with an D C asterisk(*)are UL Listed and SIZE A B C maintain a NEM AType 6P E989NNJ 2.00 4.63 5.13 E989NNJB (50,8) 1117,6) 1130.2) 0 o Rating an Type 4I4X Rating. E989NNJ CAR A E989NNJCL TB E989NNJL O O O AB (4Y4%2) E989NNR 6.00 5.00 5.50 E989NNR-CAR 1152.11 1127,0> 1139,71 (4%4%6) I 15 j Size in S td. M aerial S td. (3,81 Inches C th. M n Mir. M i n. M n. T a T c Therm o Ctn. Part No. H x W x D Qty. AT All B C P Typical VC p Iastid W (Lbs.) E989NNJ-CAR* x 4 x B 5 11/16 35/8 N/A 2 . 160 . 155 3 E987N-CAR* 4 x4x435 11/16 31/2 N/A 4 . 160 . 155 X 4 NOTES: MATERIAL: PVC SECTION 14-14 tE989NNR-CAR* 4 x4xEB4 11/16 33/8 N/A 6 . 160 . 200 Y 5 21.. NEMA TYPES: 4/4X, 6P C SCALE 0.500 E989PP1-CAR* 5 x 5 x 244 11/16 41/2 N/A 2 . 110 . 150 E987R-CAR* 6 x 6 x 4 15 5/8 N/A 4 . 190 . 190 x DRAWING BY: E989RRR-UPC* E x 6 x 6 93 5/8 53/8 N/A 6 . 160 . 190 1 4 GENERAL NOTES E989N-CAR 8 x 8 x 4 18 81 /A 4 . 185 . 19ID N 1. ALL DIMENSIONS ARE FOR REFERENCE ONLY. ■wwAnb.com PLOTDATE: E989SSX-UPC 8 x 8 x 77 2 21/32 75/16 N/A 7 . 160 156 X 2. DIMENSIONS I N BRACKETS [ 1 E989UUN 1 2 x 12 x 4 31 15/8 111/2 111/8 4 . 160 . 190 X 2 ARE IN METRIC UNITS, DESCRIPTION: MOLDED NON-METALLIC ENCLOSURE REVISIONS E989R-UPC 1 2 x 12 x 6 2 115/16 117/8 117/16 6 . 265 . 185 X 0 F SEE ERN 2016 95 PROJECT NUM BER: FOR APPROVAL SIGNATURES ORIGINAL PROJECT NO / I ERN NO SHEET NO: REV. NO: DRAWING NO: PROJECTS NO: 5AM000006 / ( ( 2 OF 2 F WSD-AC01977 THIS DRAWING IS INTENDED FOR DESCRIPTIVE PURPOSES ONLY. AND THE RIGHT IS RESERVED TO DEVIATE FROM ANY OF THE DETAILS SHOWN HEREON. SHEET NAM E 180 w w w. c a rl o n .e o m Copyright Thomas 6 Betts - Proprietary, All Rights Reserved G Loss Automation(877)268-3700 •wwwaarlonsales.com •sales@grossautomation.com SPEC SHEET REVISIO N PAG ENUM BER: ---- SS Nor- BLUE RAVEN SOLAR Connected" 1 ' 1 1 pDrients Or PennEngineerinecompany H eyco®-T ie Liquid T& C ardgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Utim ite in Liquid Tight Strain Relief Protection PRODUCT! GLAND P ART NO. ESCRIPTION P ART DIM BJSIONS •Two new cordgrips now accom m date D c B CONFIGURATION A ©/JR the Enphase 0 Cable—M 231 GCZ Conductors o r learance Max.O.A. Thread enching Nut (1/2""NPT)and M 3234GDA-SM Type Size N 0. B lack H 911�5 Ole Dia. L angth eOgth hickness Flat Size (3/4""N PT). mm. niIm .n.iIm .n.lmm. niIm .n.i1mm. Oval Gland •The 1/2-version provides liquid tight Q Cable 16,11 x9,711 0 231GCZ L I TCG 1/2 6.1x9.7M M 1@/snl 875122,211.701 43,21.61 115,51.21 I5,31. 98124,9 entry for one Enphase 0 Cable— Break•Thru Skinned Over Gland .24 x.38""(6,1 x 9,7 mm) o Cables 6.1 x 9.7 2 SMCG 314 2.6.1x9.7MM •The 3/4"version provides liquid tight W� 3,3 M3234GOA-SM 33MM SI@,.ow 26.4 2.0050.8 .62 15.7 .25 6.4 1.30 33.0 entry for up to two Enphase 0 Cables— GrDund 1 1 1 .24 x.38"(6,1 x 9,7 mm)and an M dal Locknuts INCLUDED. B additional.130"(3,3 mm)dia.hole for c a t8 solid grounding cable. 7 •The 3/4-version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. •Rated for use with DIG Cable. SUGGESTED CLEARANCE HOLE SEALING NUTJ VINTEGRAL FOR NONTHREADED M WNTING SEALING RING M Serial Nylon 6/6 with TPE Sealing Gland Certifications L © isted under Underwriters'Laboratories File E504900 &P CSA Certified by the Canadian Standards Association File 93876 Flamm hility Rating 9 4V-2 Tem perature Range S tatic -40oF(-40oC)to 239°F(115°C) Dynam c-4°F(-20oC)to 212°F(100°C) IP Rating IP 68 ALL NEW H eyco®H elios® U VX C Ip - Blind Mount PRODUCT! PANEL THICKNESS RANGE W RE DIAM ErER P ART NO. D ESCRIPTION M UNTING OVERALL •The jersey pine tree mounting style RANGE H 0LE DIA. H EIGHT installs easily with superior holding M him Ua M AM tm 1 -2 W Tres A power. in. P m. ri. mm. n.i I m m. n.i m m. .UVX nylon protects from corrosion due 1-2 W'res to outdoor exposure. 23(5,8 m m}.32(8,0 m m -S6520 elios UVX Clip 100 Pack 028 7 . 250 4 each cable S6560 elios UVX Clip Bulk 260 6 ,6 96 4,4 Installs into.260""(6,6 m m)Tt writing hole. •Holds up to 2 cables between .230- ' .315""(5,8-8,0 m m Pach. •Cables install with fingertip pressure. c . A •M dded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our _T Solar 20 Year W aranty. M aerial N ylon 6/6 with extended UV Capabilities Flamm hility Rating 9 4V-2 Tern p:rature Range D ynam c -4°F(-20°C)to 185°F(85'C) 1-800-526-4182•732-286-1800(NJ)•FAX:732-244-8843•www.hoyco.com 1-4` DRAWING NUMBER: SS Nor- BLUE RAVEN SOLAR SFM INFINITY - - U N I RAC SHOP- BETTER SOLAR STARTS HERE 000i if UL2703 SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PART NAME D ESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY TRIMRAIL S tructural front trim provides aesthetic and aligns modules. Make two installs per day your new standard.SFM INFINITY has fewer TRIMRAIL SPLICE C onnects and electrically bonds sections of TRIMRAIL. roof attachments,one tool installation,and pre-assembled components to get you off the roof 40%faster. TRIMRAIL FLASHKIT A ttaches TRIMRAIL to roof.Available for comp shingle or tile. Ica 17 SFM INFINITY 15 Attachments% PREFER MODULE CLIPS S ecure modules to TRIMRAIL. 1111111111101h.. LAW MICRORAIL C onnects modules to SLIDERS.Provides post-install array leveling. ' BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. with integrated front trim,trim end caps,dark components,and ATTACHED SPLICE also available. recessed hardware. SLIDER FLASHKIT R oaf attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density With fewer SKUs and compact components,SFM INFINITY is easier to without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES attachments required by rail. stock,easier to transport,and easier to lift to the roof.Plus,make more PART NAME D ESCRIPTION efficient use of your vehicle fleet. TRIMRAIL ENDCAPS C avers ends of TRIMRAILfor refined aesthetic. TRIMRAIL BONDING CLAMP E Iectrically bonds TRIMRAIL and modules 0 N/S BONDING CLAMP E Iectrically bonds rows of modules • • • • SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR W ff H BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. DRAWING NUMBER: SS I I I *1� SUN i BLUE RAVEN SYSTEM BONDING & GROUNDING 9 SOLAR mr FRAME me_____ -__S-FM -MICRORAILTM INSTALLATION GUIDE ; PA GE �• e I L�u I I I LAI' I 11dil E-W BONDING PATH: E-W m odule to m odule bonding is accom plished with 2 pre-installed bonding pins which engage on the secure side of the M brorailTM and splice. I I Star Washer is W EEBLUG Single Use Only Single Use Only � Alternate m shod N-S BONDING PATH: TERM NAL TORQUE, N-S m odule to m odule bonding is Install Conductor and accom pushed with bonding clam pwith 2 integral torque to the following: TERM NAL TORQUE, TERM NALTOROUE, bonding pins. (refer also to alternate m ethod) 4-6 AW Cc 35in-lbs Install Conductor and Install Conductor and 8 AW Q 25 in-lbs torque to the following: torque to the following: 10-14 AW Cc 20 in-lbs 4-14 AW a 35in-lbs 6-14 AW a 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Rsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) W ley W EEBLug (6.7) • 10-32 m canting hardware • 1 /4" m canting hardware • 1 /4" m canting hardware • T orque = 5 ft-lb • T orque = 75 in-lb • T orque = 10 ft-lb Alternate m Ethod • A W G4-14-Solid or Stranded • A W G4-14-Solid or Stranded • A W G6-14-Solid or Stranded TRIM PAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUM NUM CONTACT TO PREVENT CORROSION Trim rail to m odule bonding is accom plished with System bonding is accom dished through m (dules.System grounding accom Aished by attaching bonding clam pwith integral bonding pin and a ground lug to any m adule at a location on the m adule specified by the m adule m mufacturer. bonding T-bolt. prefer also to alternate m shod) DRAWING NUMBER: SS Nor- SUN i BLUE RAVEN UL CODE COMPLIANCE NOTESZ 0 SOLAR ONS FRAME ■ ■ F M MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the m amner specified in the perform aice is inherent in the SFM design,and no additional m Ligation m EDsures SUNFRAM EM CRORAIL (SFM )Installation Guide. SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required m him urn or m acim urn height Lim Cation above the roof deck to m antain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM .SUNFRAM EM CRORAILT"com ponents shall B & C system level perform aice for low slope & steep sloped roofs when used be m canted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 m odules. Class A, B & C system level fire Module Type R oof Slope S ystem Level Fire Raking M crorail Directiom M dule Orientation M tigation Required Type 1 and Type 2 S teep Slope & Low Slope C lass A, B & C E ast-W Est L andscape OR Portrait N one Required UL2703 TEST M CDULES See pages 22 and 23 for a list of m odules that were electrically and m a:hanically tested or qualified with the SUNFRAM EM ICRORAIL (SFM )com ponents outlined within this Installation Guide. • M a(im urn Area of M odule = 27.76 sqft • UL2703 Design Load Ratings: a) D ownward Pressure - 113 PSF / 5400 Pa b) U pward Pressure - 50 PSF / 2400 Pa c) D own-Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) D ownward Pressure - 170 PSF / 8000 Pa b) U pward Pressure - 75 PSF / 3500 Pa c) D own-Slope Load - 32.4 PSF / 1550 Pa • M a(im urn Span = 6ft • Use with a m a<im urn over current protection device OCPD of 30A • System conform sto UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • P V m odules m air have a reduced load rating, independent of the SFM load rating. Please consult the PV m odule m anufacturer's installation guide for m are inform ation • D own-Slope design load rating of 30 PSF/ 1400 Pa for m cdule areas of 22.3 sq ft or less DRAWING NUMBER: SS I *1� SUN i BLUE RAVEN TESTED / CERTIFIED MODULE LIST1 22 SOLAR OEM ISF MFRAME on MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ Ma ufacture M dine M odel/Series [Manufacture M dine M odel/Series Manufacture M dine M cdel/Series Aleo P -Series Eco Solargy 0 rion 1000 &Apollo 1000 LGxxxN2T-A4 ET Solar E T-M 672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ DNA-120-(BF/M Fj26 Aptos Freedom Forever F F-M RBBB-370 01C/01K/S1C/S2W}A5 DNA-144-(BF/M Ij26 LGxxxN2T-B5 o FreeVolt M no PERC LGxxxN1K-B6 CHSM 6612P,CHSM 6612P/HV,CHSM 6612M, GCL G CL-P6 & GCL-M 6Series LGxxx(A1C/M 1C/M 1C/N1C/N1K/01C/01K/ Astronergy CHSM 6612M,HV,CHSM 6610M (BL)(BF)/(HF), Hansol TD-AN3,TD-AN4, LG Electronics OAC/OAK)-A6 CHSM 72M IC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W}E6 Auxin AXN6M 610T,AXN6P610T 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W}G4 AXN6M 612T&AXN6P612T Heliene 144HC M 6M mofacial/Bifacial Series, LGxxxN2T-J5 AXlblackprem um 60(35m m) 144HC M 90 SL Bifacial LGxxx(N1K/N1W/12T/N2W}L5 AXlpower 60(35m m) HT Solar HT60-156(M)(NDV) (-F), LGxxx(N1C/01C/01K)-N5 Axitec AXlpower 72 (40m m) HT 72-156(M R) LGxxx(N1C/N1K/N2W/O1C/01K)-V5 AXlprem ium 60(35m m) Hyundai KG,M GTG,RI,RG,TI,M(HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM AXlprem ium 72 (40m m) HiA-SxxxHG LR4-72(HIH/HPH)-xxxM Boviet BVM 6610, ITEK i T iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30m m) BVM 6612 Japan Solar J PS-60 &JPS-72 Series LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35m m) BYD P 6K & M H(-36 Series LONGi LR6-60(BK)(PE)(PB)(PH)-xxxM (40m m) JAP6 60-xxx,JAM 6-60-xxx/SI,JAM 6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30m m) CS1(H/K/U/Y) M S xxx,JAP6 k-72-xxx/4BB,JAP72SYY-xxx/ZZ, ( )( )( )( )( )( ) CS3(K/L/U),CS3K-M SAG,CS3K-(M$�P) ( ) LR6-72 HV BK PE PH PB HPH -xxxM Canadian Solar CS3N-M$CS3U-M B-AG,CS3U-(M$1P),CS3W JAP6(k)-60-xxx/4BB,JAP60SYY-xxx/ZZ, (35m m) CSSA-M,CS6(K/U),CS6K-(M/P),CS6K-M S JA Solar JAM E(k)-72-xxx/ZZ,JAM 72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40m m) JAM 6(k)-60-xxx/ZZ,JAM 60SYY-xxx/ZZ. CS6P-(M CS6U-(M iP),CS6V-M,CS6X-P M'ssion Solar EneEgy M E Series i.YY:01,02,03,09,10 Centrosolar Am erica C -Series & E-Series ii.ZZ:SC,PR,BP,HiT,IB,M W M R J M tsubishi M E & M LE Series CT2xxM xx-01,CT2xxPxx-01, JKM &JKM SSeries Neo Solar Power Co. D 6M & D6P Series CertainTeed CTxxxM)o(-02,CTxxxM-03, CTxxxM v-04,CTxxxHC11-04 Jinko Eagle JKM)xxM JKM)xxM 72HL-V Dehui D H-60M Kyocera K U Series • Unless otherwise noted,all m odules listed above include all wattages and specific m odels within that series. Variable wattages are represented as "xxx" • Item sin parenthesis are those that m ay or m N not be present in a com patible m odule's m odel ID • Slashes 7" between one or m cre item sindicates that either of those item sm air be the one that is present in a m odule's m odel ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar m odule selected is approved for use with SFM • SFM Infinity is not com patible with m odule fram eheight of less than 30m mand m are than 40m m .See M odule M aunting section, page 12 for further information DRAWING NUMBER: SS *1� i SUN i BLUE RAVEN 23 SOLAR OEM ISF MFRAME on MICRORAIL TM INSTALLATION GUIDE ; PAGE ________________________________________________________________________________________________ Ma ufacture M dine M odel/Series Manufacture M dine M odel/Series Manufacture M dine M cdel/Series EVPVxxx(H/K/PK), TwinPeak Series V Suniva M Series & Optim LE;Series VBHNxxxSA15 & SA16, TwinPeak 2 Series A-Series A400-BLK,SPR-M AX3-XXX-R, SunPower VBHNxxxSA17 & SA18, REC Solar(cont.) TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M Y2(XV) Suntech S TP,STPXXXS-B60/W rhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38m m) TP572,TP596,TP654,TP660, VBHNxxxZA01,VBHNxxxZA02, TP4(Black) Talesun TP672,Hipor M,Sm at VBHNxxxZA03,VBHNxxxZA04 Renesola V itrus2 Series & 156 Series SC,SC B,SC B1,SC B2 Peim a- S GxxxM FB/BF Risen R SM 72-6 M DG M RSM 60-6 Tesla ( ) ( ) ( ) TxxxH,TxxxS Phono Solar P S-60,PS-72 SEG Solar SEG-xxx-BM allV PA05,PD05,DD05,DE06,DD06,PE06, Prism Solar P 72 Series SEG-xxx-BM aTB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy S N72 & SN60 Series(40m m) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim S EG-6 & SRP-6 Series UP-M xxxP(-B), O.PEAK DUO BLK-G6+ Upsolar Sharp N U-SA& NU-SC Series � UP-M)ocxM(B) O.PEAK DUO BLK-G6+/TS Silfab BLK -G8 SLA, SLG,BC Series & SlLxxx(BL/NL/NT/HL/ D7M)xxH7A,D7(M jOxxxH8A O.PEAK DUO + ( ) ( ) M l/BK/NX/NU/HC) United Renewable Energy FAKxxx(C8G/E8G),FAM x(xE7G-BB O.Cells O.PEAK DUO L-G8.3/BFF Solarever USA S E-166*83-xxxM 120N (URE) FAM)xxE8G(-BB) O.PEAK DUO(BLK) M L-G9(+) FBM vxM FG-BB PowerXT-xxxR-(AC/P D/B D) O.PEAK DUO XL-G9/G9.2/G9.3 Eldora, Solaria PowerXT-xxxC-PD O.PEAK DUO(BLK) M L-G10(+) PowerXT-xxxR-PM (AC) Vikram Solivo, O.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Som era O.PEAK DUO BLK M L-G10+/t SOLarW a-ld Sunm odule Protect, Sunm odule Plus W agree A C &Adiya Series Alpha (72) (Black)(Pure) SS-M 360 to 390 Series, S W i-laico W T&W SP Series RECxxxAA PURE-R SS-M 390 to 400 Series, Yingli Y GE &YLM Series RECxxxNP3 Black N-Peak(Black) Sonali SS-M 440 to 460 Series, ZN Shine Z XM 6-72, ZXM 6-NH144-166 2094 - REC Solar N-Peak 2 (Black) SS-M 430 to 460 BiFacial Series, SS 230-265 PEAK Energy Series PEAK Energy BLK2 Series _SunEdison F -Series,R-Series & FLEX FXS Series PEAK Energy 72 Series • Unless otherwise noted,all m odules listed above include all wattages and specific m odels within that series. Variable wattages are represented as "xxx" • Item sin parenthesis are those that m aj or m air not be present in a corn patible m odule's m odel ID • Slashes "/" between one or m cre item sindicates that either of those item sm air be the one that is present in a m odule's m odel ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar m odule selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not corn patible with m odule fram eheight of less than 30m mand m a-e than 40m m .See M odule M cunting section, page 12 for further inform a:ion SS NOW- BLUEtertek Lntertek RAVEN AUTHORIZATION TO MARK AUTHORIZATION TO MARK SOLAR Total Quality.Assured. Total Quality.Assured. This authorizes the application of the Certification Mark(s) shown below to the models descnbed in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s; Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac. Inc Manufacturer: 1411 Broadway Blvd NE 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer n' Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA fly Y Report Issuing Office: Intertek Testing Services NA, Inc.. Lake Forest. CA\ Control Number: 5003705 Authorized by: }� Control Number: 5014989 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder. Certification Manager COT! US C0' ToUS rl R Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. Tt"AyVlpnl:~to Mirk r►sor We aaflNMVe ufe or WOW WS Clan!and b W011116ed punsuirs 10 Vie Ce/baCabOn apreannenl bWweon Inaenek and ns Client MUAak's rasporurbtdy and babtrty an Ths A,pno"abon to hark is for Vne*,ick yVe uM or WftlWs Chem and is proinaw purauara to M cablication sgreer M OeUveen ween ek and rib Caerit.ki~**reepansDaty r+d klbaty are amsed so w4 wins and oonciaorn of ow agreernwo IrtMrOsk easdisfss no kabMy to any party.oWw Man to dta Client in accordance wo the/QrNInNnt,for any toss,elpenae or dannage o0rd4ipW Irrnted to"ale W-ft and can600rK of Ihe IQ/eafrtelM I/ltsltsk aesl/rMs no lisbiley to and D'anY.OV1M Vfan to VM client in aoCOrdYK1 wM tine agraMlara.for arryr IOss,alpMiM W darnaga OOCaMOnm: by Vta use of Vks AW10"MtWl to Mark Only the OWN is autl+Wind to paint Copy r9 of diWlbA n of Vila Ar41lpt2aa71 to Mack ano then only in rib ariboli use of IrWMtsk't CsNhoation mark is b/the use of d"AuVfonSaaWl W Mark Only Via Cai a aiAPW M so pima owfn9 or*Wfb~of the AWar ali0n to Mark and Won only n its ansroty use of ktapNKs certlacaaWt rrrank is eaaVttled to the condlfaa Wd one in fM ease ne t and in tlW AuMgrfiatlon to Mars,My furfler use of ma Inlertek no"for the We or adrerlisernent of It*tested nHlenal-product at spume must reltnceed to VN t'onallbau herd out n the&We*d. and In Uks k0i orizabon to Mark Any 6~uw of IM I ON manna for Via We W advate"" ri of V*leered nleserol,pfoctwo or wove n-- SM be approded in wimp by I iw Initial Factory At"Gonse Ya aid Fellow u0 Sernoee are 1W the pipits of maw"appropri use"of the Carbfraaon mark in accordance we VM sru be approved in venting by Vdw%k-Inloal Factory Ala&%an*rri,%od Follow up Senn"pre for dla plposa of assuring appfopnaM usage of the Cwbficetion+wk,n accordar ce wM the spew —V"we rich for Ute purpcl s of prodi quasi core and do not reaevs Vne Clara of Vnair obligations in the respect a;rewn@M they are not for the pwpows of p v*AZw qui aty ccrtrd, J do nor ekeve the Client of thew obligations in Vas respect Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems,Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Fia:- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed Standard(s): .1+R:24Mar2021) Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed,1+R:24Mar2021j PV Module and Panel Racking Mounting System and Accessories[CSA TIL No,A-40:20201 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No. A-40:20201 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued: 17-May-2023 ED16.315(1•Jul-2022)Mardatny ED103.15(t.Aa2022)Mandelory DRAWING NUMBER: SS Nor- BLUE RAVEN Lntertek �ntertek SOLAR AUTHORIZATION TO MARK AUTHORIZATION TO MARK Total Quality.Assured. Total Quality.Assured This authorizes the application of the Certification Mark(s) shown below to the models described In the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Products) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and Is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE 1411 Broadway Blvd NE Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest. CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest,CA i Control Number: 5019851 Authorized by: 4��ax>r>L Control Number: 5021866 Authorized by: EhMm for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C US C US t re rcO Intertek InteMk This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. this Authorvat.n to Mark is for M&XI awe use of InWtok's Client and a provded pursuant so the Certification geMrrra between trMarlaI er10 It$CI WM l llarlek's mapprpWWly end aaburty,are lhs/udMnzwtwn to Mark n for the aaCAle"use of Irlistte"Client and is prodded pure nt to ter G bfi ubw agmernent 1»t+.wn IntMNc and b Clara.IrtIMOSR'f resporig"ty ef10 f ly we Itneled to the biro and cordaOns of the Igfeerrore Inlsrbk"Writes no liability to any party,other Ron to V*G1MM m woordance snth the ageermint,for any IOU.espenee of dawns"oaasw d Imtad W the aim and conditions of to geereent,Ift assures no liability to any party.otter that to the Client in aaordance woh the agrMment,for any ION,elpMrN of dNnaQe oocetlOrw:, by to use of ens Auatonzaopn to Mark Only the Caere a authorved o perms oopyng or distribution of fro Aulonitaapf to Mark and than orgy In its entirety Use of InOMsk'a carli6CJlon rrkak is cy the use of this Authavaton 10 aaark.Only ay Clem I$aut onzed tD pernst copying or datrOuton d this Authorization to Mark and then only in n eMrety use of 10,16 6 CerleoaMM mirk to restricted o der condaroFw end our In the apreemant and n this Awithorv,non to Mark Any lutRer use of the Ireertak Fume for dy sale or adrerbsmffwY Of sly tested malenal-product ar servos must rntrKtad to the condtuomu lard out In dy agmarrent and In ski AuOtonzaton to Mark Any further use of"hrlartek nano for fe sale or advertisement of ter soared rrlalNtal,product or aantce mnr Mal be approved in writing by MlerMk.Initial Factory Asseavrents and Follow up Services are for the purpose of assung appropriate usage of ter CeAuhnMan mark In accordance with the "I be approved to wtNp by ItDenek lrrpal Faclory Astioun nls and Fobw up Servres are for fee purpose of assuring appropriate usage or the Certification mark In accordance with the agreenenl,d1e'1'ate not for pry purposes of production quality control and do nay m4—It.Oere.(it-.,obhgal—rn this respect agreomm t they ore not ix Te purposes of production quality control and do not relieve the Client or their otilgahons in this respect Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road.Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights.IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices.and Ground Lugs for Use with Flat Standard(s): Standard(s): Plate Photovoltaic Modules and Panels(UL 2703:2015 Ed.1+R.24Mar2021] Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:20201 PV Module and Panel Racking Mounting System and Accessories(CSA TIL No.A-40:20201 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide. PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued: 17-May-2023 ED 1631511-Jul-20221 Mardau_ry ED 1t 3 15(1144-20?21 Atu,t.r..y DRAWING NUMBER: SV Nor- intertek Listing Constructional Data Report (CDR) intertek Listing Constructional Data Report (CDR) BLUE RAVEN Total Quality.Assured. Total Quality.Assured. LAR 1.0 Reference and Address 1.0 Reference and Address Report Number 102393982LAX-002 O rt inal 11-A r-2016 R evised: 5-0 d-2022 Report Number 102393982LAX-002 O liainal 11-A r-2016 R evised: 5-0 d-2022 M canting System s, M canting Devices, Clam ping/Retention Devices, and G Ound Lugs for Use Ern al Standard(s) with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24M ar2021] PV M odule and Panel Racking M canting System and Accessories [CSA TIL No.A-40:2020] Applicant M Unirac, Inc nufacturer 2 1411 Broadway Blvd NE Address A Albuquerque, NM 87102 ddress Country C USA ountry Contact C Klaus Nicolaedis ontact Todd G aishaw 505-462-2190 Phone P 505-843-1418 hone FAX NA FAX Email E klaus.nicolaedis@unirac.com m ail toddg@unirac.com M enufacturer 3 nufacturer 4 Address A ddress Country C ountry Contact C ontact Phone P hone FAX FAX Ern ail E m ail M anufacturer 5 Address Country Contact Phone FAX Page 1 of 138 Page 2_of 138 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client Int rUk's respons t)-'ty and This report is for the exclusive use of IMertak'3 Client and is provided pursuant to the agreement between Intertek and its Client Intertek's responsibit.ty and liability are lirtuted to the terms and conditions of the agreement Intertek assumes no labildy to any party other than to the C1sent in accordance with the liability are limited to the terms and conilUons of the agreement Intertek assumes no liability to any party other than to the Client in accordance YAM the agreement.for any loss,expense or damage occasioned by the use of this report Only the Client is authorized to permit copying or distribution of this report and agreement for any toss,expense or damage occasioned by the use of this report Only the Client is authorized to permit copying or distribution of thus report and then only in its entirety Any use of the Intertek name or one of its marks for the sale or advertisement of the tested matenal. product or service must first be then only in its entirety Any use of the IntMek name or one of its marks for the sale or advertisement of the tested material. product or service must first be DRAWING NUMBER: approved in writing by Intertek The Observations and test results in this report are relevant only to the sample tested This report by itself does not imply that the approved in venting by Intertek The observations and test results in this report are relevant only to the sample tested This report by itself does not imply that the material product,or service is or has ever been under an Intertek certification program material product,or service is or has ever been under an Intertek certihcabon program S ^ Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-A r-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-A r-2016 Nor- Unirac,p 9 p p 9 p Inc Revised: 5-Od-2022 Unirac, Inc Revised: 5-Od-2022 BLUE RAVEN 2.0 Product Description 2.0 Product Description SOLAR Product Photovoltaic Mounting System,Sun Fram e M crorail Installation G dde, PUB2022SEP28 M odels Unirac SFM Brand name Unirac M odel Sim iarity NA The product covered by this report is the Sun Fram e M cro Rail roof m ounted Photovoltaic Rack M cunting System.This system is designed to provide bonding and grounding to Fuse Rating: 30A photovoltaic modules. The m cunting system em ploys anodized or m it finish alum hum brackets that are roof m punted using the slider, outlined in section 4 of this report. There are no rails M odule O Iientation: Portrait or Landscape within this product, whereas the 3" M cro Rail, Floating Splice, and 9"Attached Splice M a(im urn M odule Size: 17.98 ft2 electrically bond the m odules together form hg the path to ground. UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope The M cro Rails are installed onto the m odule fram a by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for M echanical Loading with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the m odules to the bracket. The bonding pin of the M cro Rail when bolted and torqued, penetrate Increased size M Ltest: the anodized coating of the photovoltaic m odule fram a(at bottom flange)to contact the m etal, M axim urn M odule Size: 22.3 ft2 creating a bonded connection from m odule to m odule. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG 355S2W-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. National Electrical Code, including NEC 250: G Iounding and Bonding, and NEC 690: Solar M cunting configuration: Four m ountings on each long side of panel with the longest span of 24" Photovoltaic System s or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope revision in effect in the jurisdiction in which the project resides.Any local electrical codes m ust LG 335N2W-A5, be adhered in addition to the national electrical codes. The G rounding Lug is secured to the LG 330S2W-A5 and LG 355S2W-A5 used for used for Mechanical Loading test. photovoltaic m odule, torqued in accordance with the installation m anual provided in this M cunting configuration: Six m cuntings for two m odules used with the m axim urn span of 74.5" docum ent. IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift O her optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 which requires a m him urn of 2 m cro-inverters m ounted to the sam a rail, and using the sam e Certifications, & Increase SFM System UL2703 Module Size: engage cable. M axim um M odule Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G 5used for Mechanical Loading test. M cunting configuration: Four m ountings on each long side of panel with the longest span of 24" M an am urn m odule size: 21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower m odel SPR-A430-CO M M LSD used for M echanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations m ust include Trim Rail. -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations m ust include Trim Rail. -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5"gap between the bottom of the m odule and the roof's surface See section 7.0 illustractions# 1, 1 a and 1 b for a com plete list of PV m odules evaluated with these racking system s O her Ratings NA DRAWING NUMBER: ED 16.3.15(1-Jul-2022)Maidatory ED 16.3.15(1-Jul-2022)Maidatory S C RESIDENTIAL ROOFTOP SOLAR PERMIT PACKAGE Enphase -= dIN6 CITY OF ARLINGTON Platinum BLUE RAVEN Mike Lamb Installer BUILDING DEPARTMENT 1403 N 630 E ---- 8109 Crown Ridge Blvd APP OVED Orem, Utah84097 PV Installation4- IS U N POWER® (800) 377-4480 Professional ARLINGTON, Washington 98223 DATE , 2 BY BlueRavenSolar.com t Gurney NO CHANGES AUTHORIZEDAuthorized Dealer #PV-01Scot1719 0 866 +13606312945 UNLESS APPROVED BY THE' BUILDING INSPECTOR SCOPE OF WORK .: SHEET INDEX p INSTALLATION OF ROOFTOP MOUNTED PV1 COVER SHEETCL j'r: PV2 SITE PLAN PHOTOVOLTAIC SOLAR SYSTEM ° } '. � r� . � PV3 ROOF PLAN c„) U PV4 STRUCTURAL N H 4 s- PV5 ELECTRICAL 3-LINE ap PV6 ELECTRICAL CALCULATIONS a` PV7 LABELS m Q N �- A. ' y PV8 PLACARD '� N 3 SS SPEC SHEETS E .� p N m U rr uIL 03 Q 5 RECEIVED 0 U 0 00 z U MAY 0 S 2024 J -C �. rz N .. _C Sealed For v�'��-- - o Zi,'S„ ti\ �, '� .✓ � Existing Roof & ...` a a N Attachment Only ff u TYPICAL STRUCTURAL INFORMATION NEW PV SYSTEM INFORMATION TOTAL PV DC SYSTEM SIZE TOTAL PV AC SYSTEM SIZE ° = ROOF MATERIAL: Comp Shingle DC SYSTEM SIZE: 6.56 kW DC 6.560 kW DC 5.200 kW AC PROJECTID: SHEATHING TYPE: OSB AC SYSTEM SIZE: 5.2 kW AC 936575 FRAMING TYPE: Manufactured Truss X. C,g RACKING TYPE: UNIRAC SFM INFINITY MODULE TYPE: (16) Silfab Solar SIL-410 HC+ �,� 'V 16VAS ZG DESIGN CRITERIA PV IX SYSTEM SIZE: ATTACHMENT TYPE: UNIRAC SFM INFINITY FLASHKIT INVERTER TYPE: Enphase IWM-72-M-USO � ��. WIND SPEED: 1 10 6.560 kW DC TOTAL ATTACHMENTS: 39 WIND EXPOSURE FACTOR: C PV AC SYSTEM SIZE _ 7 RISK CATEGORY: II NS: kW AC �• � GROUND SNOW LOAD:25 REVISIONS: GENERAL NOTES ., ROOF SNOW LOAD: 25 0 -- i� 46056 `. SEISMIC DESIGN CATEGORY: D 0 FSS10WAL WEATHER STATION DATA 0 - WEATHER STATION: BOEING FLD KING CO HIGH TEMP 2%AVG: 290C DRAWN BY: 5/2/2024 EXTREME MINIMUM TEMP: -70C Brendan Fillmore PLOT DATE: Digitally signed by .AHJ J APPLICABLE CODES May 2,2024 John A. Calvert *2020 NATIONAL ELECTRIC CODE(NEC) DRAWINGT17LE: City of Arlington WA *2015 INTERNATIONAL BUILDING CODE(IBC) Cover Sheet Date- 209,d *2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL UTILITY COMPANY 3; -Q PLUMBING CODE(IPC),AND ALL STATE AND LOCAL BUILDING,ELECTRICAL, DRAWING NUMBER: AND PLUMBING CODES Snohomish County Public Utilities District (PUD) P V 1 BLUE RAVEN — — — 1403 N 630 E Orem, Utah 84097 I (800) 377-4480 Blue RavenSolar.com I I I I I I � I } I 04 U N n I I Sealed For � � Q N 7 Existing Roof& 0 : 0 Attachment Only �_ _o 4- m m m m m m JC: O L I m m m 103 Q CL � z o >' m m m A• C4 •— Ut� a o } D �� ns1 o C� U o I ao Z U Q � E 46056 ti -C �FCISTER�A) ?�ti� W z O ISS��NAL�r z vi I ffi o IO � I 5/2/2024 u a IPROJECTID: 936575 PV DC SYSTEM SIZE: 6.560 kW DC PV AC SYSTEM SIZE: FRONT OF HOME 5.200kWAC REVISIONS: 8109 Crown Ridge Blvd 0 SITE PLAN SCALE: 1/16"= 1'-0" LEGEND PV SYSTEM SPECIFICATIONS COMPASS DRAWN BY: Brendan Fillmore ROOFTOP [BE] BREAKER [ATS] GENERATOR [RPO] REMOTE POWER TRENCH OR NEW PV SYSTEM INFORMATION PIOTDATE: JUNCTION BOX ENCLOSURE ATS PANEL OFF SWITCH OVERHEAD PV MODULE: (16) Silfab Solar SIL-410 HC+, POWER RATING:410 W May 2,2024 MICROINVERTER: Enphase IQ8M-72-M-US, POWER RATING:325 W DRAWING TITLE: UTILITY METER ®C AC DISCONNECT CT CT CABIN T HATCH UTILITY METER FIRE BACK i PROPERTY LINE Site Plan MSP PANT EL ERVICE PV METER°DUCTION BAT ESS-BATTERY MICROINVERTER NEW FI PV SYSTEM DRAWING NUMBER: ICONS WITH DOTTED OUTLINE r V SUB SUBPANEL CB COMBINER BOX ESC ESS-CONTROLLER INDICATE INTERIOR LOCATION S 1 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com 0 i-- cM U CV .L SKYLIGHT (V N 0 � C Q v> .Qm0 3 0 � m } 0 N � U 33 Q 5 i Sealed For o IL ® ® Existing Roof & U OO ® ® Attachment Only o O• �- r ® ® oo Z U U Fl N ® ® ® ® Q •� ,v A C141 -C CB � L � � o MP 1 u a --, MODULE QTY: 16 1' 46056 PROJECT ID: M MSPi AZIMUTH:211 ?6�� �t�C1 .a 936575 --J PITCH: 18 :910NAL V.4 TSRF:95 PV DC SYSTEM SIZE: UNDERGROUND SERVICE LINE 6.560 kW DC AREA: 617 ft2 PV AC SYSTEM SIZE: POINT OF INTERCONNECTION 5/2/2024 5.200 kW AC REVISIONS: FRONT OF HOME A ---- A ---- ROOF PLAN SCALE: 1/8"= V-0" COMPASS DRAWN BY: LEGEND PV SYSTEM SPECIFICATIONS Brendan Fillmore NEW PV SYSTEM INFORMATION \ PLOT DATE: ROOF TOP BREAKER GENERATOR ❑ REMOTE POWER TRENCH OR \ May 2,2024 JUNCTION BOX [BE] ENCLOSURE FATS] ATS PANEL RPO OFF SWITCH OVERHEAD PV MODULE: (16) Silfab Solar SIL-410 HC+, POWER RATING: 410 W DRAWING TITLE: UTILITY METER FIRE � MICROINVERTER: Enphase IQ8M-72-M-US, POWER RATING: 325 W MI UTILITY METER AC DISCONNECT CT CT CABINET F1 HATCH BACK i PROPERTY LINE Roof Plan Fm—s MAIN SERVICE PV PRODUCTION NEW DRAWING NUMBER: P PANEL PV METER [BAT] ESS-BATTERY MICROINVERTER PV SYSTEM ICONS WITH DOTTED OUTLINE S PV3 SUB SUBPANEL CB COMBINER BOX ESC ESS-CONTROLLER INDICATE INTERIOR LOCATION CEILING JOIST/ MAXIMUM MAXIMUM TOTAL PV ARRAY AREA 341.36 PANEL AZIMUTH PITCH TSRF AREA ROOF MATERIAL SHEATHING TYPE FRAMING TYPE FRAMING SIZE PURLINS SIZE RACKING TYPE ATTACHMENTTYPE ATTACHMENT CANTILEVER TOTAL ROOF AREA(W) 1598 COUNT (DEG) (DEG) (R) U12) AND SPACING AND SPACING SPACING(S) (C) DISTRIBUTED LOAD(psf) 2.2 MPi. 16 211 18 95 617 Comp Shingle OSB Monuiaciurea Truss 2x4 a 24 in OC 2x4 rA�24 in OC UNIRAC SFM INF-.NIFY UNIRAC SFM INFINITY FLASHKIT 72"L/48"P 24"L/16"p ROOF COVERAGE(�.) 21.36 TOTAL PV ARRAY WEIGHT(Ihs) 752 BLUE RAVEN MP2 0 TOTAL PV ATTACHMENTS 39 M P3 0 POINT LOAD(Ibs/aH.) 19.3 MP4 0 o 1403 N 6 MPS MPS 0 Orem, Utah 84097 MP7 0 (800) 377-4480 MPS 0 BlueRavenSolar.com MP9 0 MPI0 0 ATTACHMENT TYPE: PV MODULES SHALL NOT EXTEND� Unirac SFM Infinity ABOVE ROOF RIDGE LINE 0 PV MODULE 4— MAX CANTILEVER (M U PER TABLE ABOVE N H (C) UNIRAC 00 UNIRAC 70 a, PV MODULE SFM INFINITY SFM INFINITY ' Q 2" 6.5"SPLICE—MICRORAIL w m O > y > }O } rIz \ROOF MATERIAL NOT EXISTING FRAMING � � J V) U � — r SHOWN FOR CLARITY -0 ..........�/.f/%///O6dd//Dlf// ®a'dFd'. . ��95tP� ���Y/ �UU V O > Q i 7)4 MIN '; Z O � (1)5116"LAG BOLT EMBEDMENT �� WITH EPDM WASHER O� O — o U o ATTACHMENT SPACING Z U PER TABLE ABOVE J AZ— (L) Q N .E FRAMING SPACING 0 * PER TABLE ABOVE THIS DETAIL IS NOT MEANT TO BE O AN EXACT REPRESENTATION OF ATTACHMENT DETAIL a c 1 FRAMING DETAIL EXTERIOR WALL 2 SCALE: 1/2"= 1'-0" FRAMING OR PV MODULE LAYOUT SCALE: 1-1/2"= 1'-0 z N U RIDGE NOTES U Q LANDSCAPE PORTRAIT Sealed For PROJECT ID: 936575 Existing Roof & Attachment Only PV DC SYSTEM SIZE: 6.560 kW DC PV AC SYSTEM SIZE: 5.200 kW AC REVISIONS: p C4 Q -- `� 0 j- DRAWN BY: �., Brendan Fillmore 46056 � PLOT DATE: FC1wv ��ti May 2,2024 SS�tjNpL'rrGNI DRAWING TITLE: Structural FOLLOW ATTACHMENT SPACING IN TABLE ABOVE 5/2/2024 DRAWING NUMBER: EAVE *ATTACHMENT PATTERN SHOULD BE PV4 ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE SCALE: 1/4'= 1'-0" NOTED IN ENGINEERING LETTER I'. (1) 6AWGTHI-iN/IIiWN2CuB!ACK L1 (1) iOAWGTI{FiNfTHWN-2CUBLACK Ll (2) 10AWGTHHN/THWN-2CUBLACK 3/4INCH Ll (1) 10AWGTHHN/THWN-2CUBLACK 3/4INCH L1 (1) 12AWGTHHN/THWN-2CUBLACK '1 L2,(1) 6 AWG THHN/THWN-2 CU RED L2 (1) IOAWGTHHN/THWN-2CURED 3 L2 (2) l0AWGTHHN/THWN-2CURED ErnT ^ G (1) 10AWGTHHN/THWN-2CURED L2 (1) 12AWGTRE,CUWN-2CURED 5 N (1) 6 AWGTHHN/THWN-2CU WHITE 4 N (1) 10AWGTHHN/THWN-2CUWHITE G (1) 10AWGTHHN/THWN-2CUGREEN L G (1J lOAWGTHHN/THWN-2CUGREEN 1 G (1) 6AWGBAE,CU G (1) 10 AWG THHN/THWN-2 CU GREEN `TYPE OF CABLE MAY BE SUBSTITUTED FOR USE IN -TYPE NM(ROMEX)/UF CABLE IS PERMITTED FOR INTERIOR ENPHASE Q-CABLE,2-WIRE,FREE AIR Exterior BLUE RAVEN 3/4INCH EMT Exteror 3/41NCH EMT Exteror CONDUIT WHERE NEC CODE PERMITS OR ATTIC RUNS AND SHALL BE USED WHEN NEC CODE PERMITS 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com PRIMARY PV COMBINER BOX � o—PRIMARY STRUCTURE—� 15A 1 A (16)PV MODULES 1 B 6 MICROINVERYERS AC DISCONNECT SAFETY SWITCH (N)20A r © I�I PV CIRCUR T11 PV AR Y T p Utility Meter (E)200A Main Service Panel 60A.FUSIBLE _ 8 MODULES _ I�+ j z- XY :D DO ENVOY , r J CL 2 I I '1,, N (N)20A I PV CIRCUIT 2 1 I— PV ARRAY 2 M U ;)2DDA (EL) _ G -8 MODULES L J �I ti N N r--- — — �J 3 2 1 30A J -0 00 O0 0 (EL) FUSES O N � — (EL) s G ---- ------------------------------------------------� —� a •� }O SUPPLY SIDE TAP tail C: .0 (EL) NEC 250.24(A) J C3 _4 BOND GROUNDS A, Q AND NEUTRALS VU/ 7 0 IL (EI.) j i Z O >- I •— IJ +- N I 0 D r i p (D O 0O ao Z U G I N I Q E I 0�------------------------------------ O UNDERGROUND SERVICE ' 120/240 VAC,60 Hz -j z O C: 1 PHASE,3 WIRE - N °C O GENERAL NOTES o Utility Meter Number.81182878 Interconnect using a supply side tap in MSP,interior POI. U a _ PROJECT ID: LEGEND _ 936575 (E) EXISTING (PV) PV BREAKER CR. 1 1' (N) NEW (FIB) FACTORY INSTALLED BREAKER S � ��`-- - ��}'• �- PV DC SYSTEM SIZE: (EL) EXISTING LOADS SPD SURGE PROTECTIVE DEVICE ( 6.560 kW DC (RL) RELOCATED LOADS MI MECHANICAL INTERLOCK _ PV AC SYSTEM SIZE: EQUIPMENT NOTES EQUIPMENT DESCRIPTIONS P:� 1 _ 5.200 kW AC O FINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER.MUST COMPLY WITH MAX A PV MODULE:Silfob Solar SIL-410 HC+,410 W DC,UL 1703/UL 61730 COMPLIANT REVISIONS: MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. g MICROINVERTER:ENPHASE IQ8M-72-M-US,325 W AC(0.325 kW),1 PHASE,UL 1741 COMPLIANT Q A OC ROOFTOP JUNCTION BOX:EZ SOLAR JB-1.2 JUNCTION BOX @ JUNCTION BOX:PVC 4 X 4 JUNCTION BOX 3O E PV COMBINER BOX:ENPHASE IQ COMBINER 4(X-IQ-AMl-240-4) OF SQUARE-D SAFTEY SWITCH 60A,2P,240VAC,FUSIBLE(DMNRB) ^ DRAWN BY: 0 Brendan Fillmore PLOT DATE: O May 2,2024 7 Q � L 6 AWG SOLID COPPER GEC TO BE IRREVERSIBLY SPLICED TO(E)GEC TO COMPLY WITH NEC DRAWING TITLE: < 250.64(D)(1). O OTHER NOTES N Electrical O9 GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. O 3-Line ©-- DRAWING NUMBER: 10 117 PV5S ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. 12 T '111�*' ELECTRICAL INFORMATION PV BREAKER BACKFEED CALCULATIONS DESIGN LOCATION BLUE RAVEN UTILITY ELECTRICAL SYSTEM NEC 705.12(B)-"120%RULE" AND TEMPERATURES I-Phase,3-Wire,60H7 1201240V (BUSBAR RATING.120%)-OCPD RATING=AVAILABLE BACKFEED DATA SOURCE ASHRAE Weather Station Data NEW PV SYSTEM MAIN SERVICE SUBPANEL 1 SUBPANEL 2 STATE Woshington 1403 N 630 E PANEL CITY ARLINGTON Orem, Utah 84097 I-Phase,3 Wire,60H7 1201240V BUSBAR RATING 200A —A —A E 5.2kW AC WEATHER STATION BOEING FLD KING CO (800) 377-4480 AC SYSTEM SIZ PANEL OCPD RATING 200A —A --A HIGH TEMP 2%AVG 29°C PV MODULES AVAILABLE BACKFEED(120%RULE) 40A ##A ##A EXTREME MINIMUM TEMP -7°C Blue RavenSolar.com DC SYSTEM SIZE . kW DC PV BREAKER RATING 30A 30A 30A QUANTITY 16 TYPE Silfab Solar SIL-410 HC+ `THESE CALCULATIONS ARE ONLY APPLICABLE IF PV INTERCONNECTION IS A LOAD SIDE BREAKER.'PV BREAKER MUST BE RATED LESS THAN OR EQUAL TO WATTAGE 41 OW DC AVAILABLE BACKFEED FOR CODE COMPLIANCE* MICROINVERTERS TYPE Enphose IQ810-72-M-US 0 OUTPUT CURRENT 1.35A AC NOMINAL VOLTAGE 240V AC OUTPUT POWER 325W AC L'M U N H WIRE SIZE SPECIFICATIONS 00 0 0 © @ �o Q H cc 0 MINIMUM CONDUCTOR AMPACITY 13.5A AC 13.5A AC 13.5A AC 27.08A AC 27.08A AC —A AC —A AC —A AC —A AC --A AC CONDUCTOR MATERIAL CU Cu CU CU CLI CONDUCTOR TYPE THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 — CONDUCTOR SIZE 12 AWG 10 AWG 10 AWG 10 AWG 6 AWG H (J CONDUCTOR AMPACITY 30A 40A 40A 40A 75A —A —A —A —A —A AMBIENT TEMPERATURE ADJUSTMENT FACTOR 1 CONDUIT FILL ADJUSTMENT FACTOR 1 1 0.8 1 1 — — r/ Q CL ADJUSTED CONDUCTOR AMPACITY 30A 40A 32A 40A 75A —A —A —A —A —A Z 0 WIRE RUN DISTANCE(FT) 52 50 20 5 10 — — — U CALCULATED VOLTAGE DROP 0.52% 0.56% 0.22% 0.11% 0.09% 0% 0% 0% 0% 0% 0% O } o CD U o PV CIRCUIT SPECIFICATIONS 00 Z U PRIMARY STRUCTURE DETACHED STRUCTURE J w L CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 CIRCUIT 6 CIRCUIT 7 CIRCUITS CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS Q E NUMBER OF MODULES PER CIRCUIT 8 8 0 0 0 0 0 0 0 0 0 0 0 • RATED AC OUTPUT CURRENT(6,) 10.BA 10.8A 0.0A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O 0 MINIMUM AMPACITY Ng x 125%) 13.5A 13.5A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA OVERCURRENT PROTECTION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A Z O a COMBINED AC OUTPUT CURRENT(C.,,) 21.6A O. i N MINIMUM AMPACITY(C,,,,x 125%) 27.OA O w O COMBINED PV BREAKER RATING 30AA OAA A O C j U Q TOTAL PROJECT ID: VOLTAGE DROP 936575 VOLTAGE DROP WIRE TAG#1 0.52% PV DC SYSTEM SIZE: WIRE TAG#2 0.56% 6.560 kW D WIRE TAG#3 0.227, PV AC SYSTEM SIZE: WIRE TAG#4 0.11% WIRE TAG#5 0.09% 5.200 kW AC WIRE TAG#6 0% REVISIONS: TOTAL 1.500000% Q ___ A A ---- A - - DRAWN BY: Brendan Fillmore PLOT DATE: May 2,2024 DRAWING TITLE: Electrical Calculations DRAWING NUMBER: p v6 WARNING LABELS BLUE RAVEN UTILITY METER MAIN SERVICE PANEL AC DISCONNECT 1403 N 630 E Orem, Utah 84097 (800) 377-4480 PHOTOVOLTAIC SYSTE.1 BlueRavenSolar.com ! AC DISCONNECT [ RATED AC OUTPUT CURRENT 21.6 A NOMINAL OPERATING AC VOLTAGE 240 VJ WARNING CL ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND •U LOAD SIDES MAY BE ENERGIZED PV COMBINER BOX N h IN THE OPEN POSITION -0 w SOLAR PV SYSTEM EQUIPPED > Q NET METER WITH RAPID SHUTDOWN RAPID • O 3 N TURN RAPID SHUHxnvN •- • - PHOTOVOLTAIC SYSTEM _,�_'{.� +- SWITCHTOTHE U O 'OMPOSRION TO COMBINER PANEL SHUTDOWN PV SnTEM AND HAZARD OWARNING a � N SHOCK HAZARD IN THE ARRAY AUTHORIZED C O •— Q PERSONNEL ONLY 30 � Q � DO NOT ADD LOADS % `0 NO DC WIRES PRESENT jg U O } RAPID SHUTDOWN TEST NOT REQUIRED p U 0 0o z U De J A_—C Q •C O O z Z 0 0 U O U PROJECT ID: © CAUTION 936575 MULTIPLE SOURCES OF POWER PV DC SYSTEM SIZE: 6.560 kW DC POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED PV AC SYSTEM SIZE: SOLAR ARRAY.PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE 5.200 kW A OF SIGHT OF UTILITY METER. REVISIONS: Q -- AB - AWARNING � 0 - DUAL POWER SUPPLY DRAWN BY: SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM Brendan Fillmore PLOT DATE: May 2,2024 DRAWING TITLE: IN CASE OF EMERGENCY, Warning PLEASE CONTACT. BLUE RAVEN SOLAR Labels (800)377�480 DRAWING NUMBER: PV7 •0 o ELECTRICAL SPECIFICATIONS 410 ` • Test Conditions STC 306 BLUE RAVEN • � • 06 Module Wp 410 SILFAB PRIME 36.24SILFAB Maximum powervoltage(Vpmax) V 38.99 .43 SO L A RO Maximum powercurrent(Ipmax) A 10.52 Open circuitvoltage(Voc) V 45.59 42.7.76 SIL-410 HC+ Short circuit current(Isc) A 11.15 8.99 Module efficiency % 20.7% 19.3% Maximum system voltage(VDC) V 1000 Series fuse rating A 20 PowerTolerance Wp 0 to+10 Measurement conditions:STC 1000 W/ma•AM 1.5•Temperature 25°C•NOCT 800 W/ma•AM 1.5•Measurement uncertainty s 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 21.3kg±0.2kg 47lbs±0.41bs Dimensions(H x Lx D) 1914 mm x 1036 mm x 35 mm 75.3 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)' 5400 Pa rear load/5400 Pa front load 112.8lb/fN rear load/112.8lb/ft'front load Hail impact resistance a 25 mm at 83 km/h e 1 in at 51.6 mph 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC Cells 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, anti-reflective coating anti-reflective coating Cables and connectors(referto installation manual) 1350 mm,a 5.7 mm,MC4 from Staubli 53 in,a 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, Fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS 1NARRANTIES Temperature Coefficientlsc +0.064%/°C Module product workmanship warranty 25 years- Temperature Coefficient Voc -0.28%/°C Linear power performance guarantee 30years Temperature -0.36%/°C a97.1%end lstyr P >91.6%end 12th yr NOCT(±2°C) 45°C >_85.1%end 25th yr Operating temperature -40/+85°C t82.6%end 30thyr CERTIFICATIONS SHIPPING SPECS UL 61215-1:2017 Ed.1,UL 612154:2017 Ed.1,UL 61730-1:2017 Ed.1,UL 61730-2:2017 Modules Per Pallet: 26 or26(California) E.d.i,CSA C22.2961730.1:2019 Ed.2,CSA C22.2x61730.2:2019 Ed.2,IEC 61215 1:2016 Product EdA,IEC 61215-2:2016 Ed.l,IEC 617301:2016 Ed.2,IEC 61730-2:2016 Ed.2,IEC pallets Per Truck 32 or30(California) 617011020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Corrosion),CEC Listing,UL Fire Rating:Type 2 Modules Per truck 832 or780(California) Factory IS09001:2015 O Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. " 12 year extendable to 25 years subject to registration and conditions outlined underWarranty"atsitfabsolar.com PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads. J m _ -75.3"[1914mm] E `v E 12.1"[307mm]` 51.2(1300mm] 12.1^[307mm] RELIABLE ENERGY. I ' SILFAB SOLAR INC. � DIRECT FROM THE SOURCE . MouMittg Hole(x4) o 800 Cornwall Ave� 5'0.5' Bellingham WA 98225 USA ` a«a.+,. y [12mm] nfo@s/absolar.com Designed to outperform. 20:3 ; J S I L F A B S O L A R.C OM PVM-.7 1 I E E 1770 Port Drive Dependable, durable, high-performance , 1 e "r,ua it 12b1.ca.a p, ° E / 0 Burlington WA98233 USA solar panels engineered for North 1.4"[35rnmL [� opo E o T+1 360.S69.4733 American homeowners. Imo; _ "� t 1 co 240 Courtneypark Drive East ': v Mississauga ON L5T2Y3 Canada 2501 SILFABSOLAR.COM E= T+1905.696.0267 53.15" "! c F+1 905.69fi.0267 3 0.06" v C. [1.5mrn) - [1350mm] ID Cable Length 2 Silfab-SIL-4IO-HC+-20230726 S 0 No reprod.aion of-y kind�s atiowed w�thou� _ O parmhvon,Dab and mrwmation is wb,c to 17f'8111�8 Hole(XS) O G mod�canans wishnvf notl.CSu:b Sol.,inc, f t l i r 1 2022.Silfab Solar-is a registered trademark of r-� 1 I L raunhofe,j- l �, y _ - 1 sllfab Solar Inc DRAWING NUMBER: L�-'�Ji E 2.4'[BOmm] B"[200mm] SS EN PHASE. o a= IQ8M and IQ8A Microinverters BLUE RAVEN INPUT 1A 1 Commonly used module pairings' w 280-460 295-500 To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module I°.. Module compatibility Module compatibility can be checked at httDs;//enphase.com/installers/microinverters/calculator MPPT voltage range V 30-45 32-45 Operating range V 16-58 Minimum/Maximum start voltage V 22/58 Maximum input DC voltage V 60 Maximum continuous input DC current A 12 �l Maximum input DC short-circuit current A 25 Maximum module lu A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(ACI UNITS Peak output power VA 3310 366 Maximum continuous output power VA 325 349 Q 8 M and I Q 8A M i c ro i n ve rte rs Nominal grid voltage(L-L) V 240,split-phase(L-L),180° Minimum and Maximum grid voltage2 V 211-264 Our newest I08 Microinverters are the industry's first microgrid-forming,software- Maximum continuous output current A 1.35 1.45 ll insta defined microinverters with split-phase power conversion capability to convert DC Easy to Nominal frequency H= 60 power to AC power efficiently.The brain of the semiconductor-based microinverter Lightweight and compact with plug- and-play connectors Extended frequency range Hz 47-68 is our proprietary application-specific integrated circuit(ASIC),which enables Power line communication(PLC) the microinverter to operate in grid-tied or off-grid modes.This chip is built using between components AC short-circuitlfaultcurrentover Arms 2 advanced 55-nm technologywith high-speed di ital logic and has superfast three cycles g' g� p Faster installation with simple two- response times to changing loads and grid events,alleviating constraints on battery wire cabling Maximum units per 20 A(L-L)branch 11 circuit' sizing for home energy systems. High productivity and reliability Total harmonic distortion % `5 Produce power even when the grid Overvoltage class AC port III / is down* I __EnphaseMore than one million cumulative AC port backfeed current mA 30 7 ' hours of testing 1.0 Power factor setting `25 Class II double-insulated enclosure Grid-tied power factor(adjustable) 0.851eading...0.851agging year limited Optimized for the latest high- 97.7 warranty powered PV modules Peak efficiency % CEC weighted efficiency °� 97 Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability g Microinverters integrate with the IQ Battery, standards with more than one million MiCompliesforming • Complies with the latest advanced Nighttime power consumption mW 22 IQ Gateway,and the Enphase App monitoring and cumulative hours of power-on testing, P id analysis software. enabling an industry-leading limited warranty grid support" MECHANICAL DATA of up to 25 years. Remote automatic updates for the latest grid requirements Ambient temperature range -40°C to 60°C(-40°F to 140°F) Confi g u ra ble to su pport a wide Relative humidity range 4%to 100%(condensing) _ range of grid profiles Meets CA Rule 21(UL 1741-SIB and IEEE DC connector type Staubli MC4 • 1547:2018(UL T741-SB 3'0 Ed) Dimensions(H•W•D) 212 mm(8.3")•175 mm(6.9")x 30.2 mm(1.2") CERTIFIED Weight 1.1 kg(2.43 Ibs) NOTE • IQ8 Microinverters cannot be mixed together with Cooling Natural convection-no fans Connect PV modules quickly and easily to the I08 Series Microinverters are UL Listed as previous generations of Enphase microinverters yes IQ8 Series Microinverters that have integrated PV rapid shutdown equipment and conform (107 Series,IQ6 series,and so on)in the same Approved for wet locations MC4 connectors. with various regulations when installed system. Pollution degree PD3 according to the manufacturer's instructions. IQ Gam,•,ay Is required to change the default grid Classlldouble-insulated,corrosion-resistant polymeric enclosure profile atthe time ofinstallationtomeetthelocal Enclosure Authority Having Jurisdiction(AHJ)requirements. Environmental category/UV exposure rating NEMA Type 6/outdoor •Meets UL 1741 only when installed with IQ System Controller 2. ••IQ8M and I08A support split-phase,240 V installations only. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. DRAWING NUMBER: IQBMA-MC4-DSH-00205-2.0-EN-US-2023-11-03 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBMA-MC4-DSH-00205-2.0-EN-US-2023-11-03J- J" Data Sheet En phase Q Cable Accessories BLUE RAVEr Enphase Q Cable Accessories c10; ,R REGION:Americas CONDUCTOR SPECIFICATIONS Certification UL3003(raw cable),UL 9703(cable assemblies),DG cable Flame test rating FT4 Compliance RoHS,OIL RES I,CE,UV Resistant,combined UL for Canada and United States Conductortype THHN/THWN-2 dry/wet Enphase The Enphase Q CableT" and accessories are part of Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ System"".These disconnect required by NEC 690. Q Cable Accessories accessories provide simplicity, reliability,and faster Q CABLE TYPES/ORDERING OPTIONS Installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Q-12-20-200 12 AWG/277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable 0-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Field-wireable connector(male) Q-CONN-10M Make connections from any open connector • Two-wire,double-insulated Enphase Q Cable Field-wireable connector(female) Q-CONN-10F Make connections from any Q Cable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling tothe racking or to secure looped cabling Enphase cable Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors,DC connectors,and AC module mount • New cable numbering and plug and play connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling wire management Terminator Q-TERM-10 Terminator cap for unused cable ends • Link connectors eliminate cable waste Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4(TE PV4-S SOLARLOK). 150mm/5.9"to MC4. Enphase EN4 non-terminated adaptor' ECA EN4-FW Forfield wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non terminated cable.150mm/5.9" Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use with split Field-Wireable Connectors cell modules or PV modules with short DC cable.600mm/23.6' • Easily connect Q cables on the roof without Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptorto MC4(max voltage 100 VDC) complex wiring Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptorto UTX(max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable within 1.Qualified per UL subject 9703. branch limits • Available in male and female connector types TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL CABLE CLIP Plan to use at least one per Used to fasten cabling tli the racking installation,sold in packs of ten a or to secure looped cabling,sold in (Q-DISC-10) packs of one hundred(Q-CLIP 100) To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ EN P H A S E. Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. E N P H A S E. DRAWING NUMBER: To learn more about Enphase offerings,visit enphase.com `/ 2020 06 26 SS FData BLUE RAVEN IQ Combiner 4/4C �.F,eet Networking MODEL NUMBER IQ Combiner 4 *Comll 4 xith IQ Gateway Famed circud boaedior Imegiaied reverwe grade PV production meterrrq(ANSt C12 2G±0-5%) X-I0•A11,111.240.4 and consumption mondoring(!2,514)Includesa silver solar shield to match the IQ Battery 8M 1Q System Controller 2 and to X2-I0-AMS-240 4(IEEE 1547-2019) deflect heat IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%) X-IQ-AM1-240-4C and consumption monitoring(±2.5%).Includes Mobile Connect cellular modem(CELLMODEM-M1-06-SP-05),a plug-and-play IQ Combiner 4I4C The IQ Combiner 4/4C with IQ Gateway and X2-IQ-AM1-240-4C(IEEE 1547:2018) industrial-grade cell modem for systems up to 60 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area)Includes a silver solar shield to match the integrated LTE-M1 cell modem (included IQ Battery and IQ System Controller and to deflect heat. only with IQ Combiner 4C) consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Supported microinverters IQ6,IQ7, and IQB.(Do not mix 106/7 Microinverters with IQ8) interconnection equipment into a single Communications Kit enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Ml-06 -IncludesCOMMS-KIT-01andCELLMODEM-Ml-06-SP-OS with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 4G based LTE-Ml cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan storage installations by providing a consistent, Circuit Breakers SupportsEatonBR210,BR215,BR220,BR230,BR240,BR250,andBR260circuitbreakers �= „•F re-wired solution for residential applications. BRK-10A-2-240V Circuit breaker,2 pole,1 OA,Eaton OR21 0 p pp BRK-15A-2-240V Circuit breaker,2 pole.1SA,Eaton BR215 It offers u to four 2-pole input circuits and BRK-20A-2P-24OV Circuit breaker,2 pole,20A,Eaton BWO p p p Circuit breaker,2 pole,l SA,Eaton BR2158 with hold down kit support BRK 15A-2P-240V-B I Eaton BR series busbar assembly. BRK20A-2P-24OV-B Circuit breaker,2 pole,20A,Eaton BR2208 with hold downkitsupport XA-SOLARSHI ELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws r _ Consumption monitoring CT A pair of 200A split core current transformers r Smart (CT-200•SPLIT/CT-200-CLAMP) ELECTRICAL SPECIFICATIONS • Includes IQ Gateway for communication and control Rating Continuous duty • Includes Mobile Connect cellular modem system voltage 120/240VAC,60 Hz (CELLMODEM-M1-06-SP-05),included only with Eaton BR series busbar rating 125A IQ Combiner 4C Includes solar shield to match Enphase IQ Battery Max.continuous current rating 6 aesthetics and deflect heat Max.continuous current rating(npu[from PV/storage) 64A A • Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 90A • Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Uptofour 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) • Provides production metering and consumption Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included ( monitoring IQ Gateway breaker 10Aor 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway Simple MECHANICAL DATA Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. X IQ•AM1.240.4C • Mounts on single stud with centered brackets 7-5 kg(16.5 Ibs) X2-IQ AM1 240 4C(IEEE 1547:2018) Supports bottom,back and side conduit entry Weight Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -40°Cto+46^C(-40"Fto115"F) plug-in breakers(not included) Cooling Natural convection,plus heat shield 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMAtype 3R,polycarbonate construction Wire sizes 20Ato 50A breaker inputs:l4to 4 AWG copper conductors 60A breaker branch input:4 to 1/0 AWG copper conductors Reliable Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors • Durable NRTL-certifiedNEMA type 3Renclosure - Always follow local code requirements for conductor sizing. Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) 1 • Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS included for both the IQ Combiner SKU's Integrated Wil IEEE 802.11b/g/n UL listed Cellular CELLMODEM-MI-06-SP-05,CELLMODEM-M1-06-AT-O5(4G based LTE-M1 cellular modem). Note that an Mobile Connect X IQ-AM1-240 4 + X2-IQ-AMl-240-4 and X2-IQ-AM1-240-4C comply with cellularmodem is required for all Enphase Energy System installations, X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 1547:2018(UL 1741-SB,3rd Ed.) Ethernet Optional,IEEE 802.3,Cat5E(or Cat6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner CA Rule 21(UL 1741-SA) U� IEEE 1547:2018-UL 1741-SB,3w Ed.(X2-IQ-AM1-240-4 and X2411-AM1-240-4C) CAN/CSA C22.2 No 107.1,Title 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) LISTED Consumption metering:accuracy class 2.5 E N P H A S E. Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 To learn more about Enphase offerings,visit enohar- com ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of IQ-C-4-4C-DS-0103-EN-US-12-29-2022 Enphase Energy,Inc,Data subject to change. DRAWING NUMBER: IQ C 4-4C DS 0103 EN US 12 29 2022 SS BLUE RAVEN Data Sheet Enphase Networking 1403 N.Research Way Enphase IQ Envoy Orem,UT84097 800.377.4480 W W W.BLUERAVENSOLAR.COM MODEL NUMBERS Enphase IQ Envoy' Enphase IQ Envoy communications gateway with integrated revenue grade PV CONFIDENTIAL-THE INFORMATION ENV IQ AM1 240 production HEREIN CONTAINED SHALL NOT BE metering(ANSI C12.20+/-0.5%)and optional consumption monitoring(+/-2.5%). USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR Includes SHALL IT BE DISCLOSED IN WHOLE OR Enphase I Env®y The Enphase IQ Envoy'"communications gateway one 200A continuous rated production CT(current transformer). IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT delivers solar production and energy consumption ACCESORIES(OrderSeperately) IN CONNECTION WITH THE SALE AND Enphase Mobile Connect' Plug and play industrial grade cellular modem with data plan for systems up to 60 USE OF THE RESPECTIVE EQUIPMENT, data to Enphase Enlighten" monitoring and analysis CELL MODEM-MI (4G based L1 E-M/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin WITHOUT THE WRITTEN PERMISSION CELLMODEM-MII-B(4G-based LTE-M1/5-year data plan) Islands,where there is adequate cellular service in the installation area.) OF BLUE RAVEN SOLAR LLC. software for comprehensive,remote maintenance and Consumption Monitoring CT P p Split-core consumption CTs enable whole home metering. , management of the Enphase IQ System. CT—zoo—SPLIT _ !NABCEP Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge'storage COMMS-KIT-01 and Enphase Enpower'smart switch.Includes USB cable for connection to IQ CERTIFIED With integrated revenue grade reduction metering Envoy or Enphase IQ Combiner'and allows wireless communication with Encharge 9 9 P g and Enpower. PV INSTALLATION and optional consumption monitoring, Envoy IQ is the POWER REQUIREMENTS __ PROFESSIONAL platform for total energy management and integrates Power requirements Max 2 0 VAC split phase. Scott Gurney Max 20 A overcurrent protection required. #PV-011719-015866 with the Enphase Ensemble-and the Enphase IQ Typical Power Consumption 5W CONTRACTOR: Battery'". CAPACITY BRS FIELD OPS Number of microinverters polled Up to 600 385-498-6700 MECHANICAL DATA ---- Dimensions(WxHxD) 21.3 x 12.6 x 4.5 cm(8.4"x 5"x 1.8") Smart Weight 17.6 oz(498 g) • Enables web based monitoring Ambient temperature range -40"to 65'C(-40•to 149'F) 40•to 46"C(-40'to 115'F)if installed in an enclosure and control Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure. Bidirectional communications for 560 feet) To 2000 meters 6, ee Altitude ( ) remote upgrades Production CT -Limited to 200A of continuous current/250A OCPD—72kW AC •Supports power export limiting and Internal aperture measures 19.36mm to support 250MCM THWN conductors(Max) zeroexport applications UL2808 certified for revenue grade metering Consumption CT For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84"x 0.96'(21.33mm x 24.38mm)to support Simple 3/0 THWN conductor UL2808 certified,for use at service entrance for services up to 250Vac • Easy system configuration using Enphase InstallerToolkit'"mobile app INTERNET CONNECTION OPTIONS • Flexible networking with Wi-Fi, Integrated Wi-Fi 802.11b/g/n Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLMODEM-M1(4G)or CELLMODEM-M1-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable COMPLIANCE Compliance UL 61010-1 Designed for installation indoors CAN/CSA C22.2 No.61010-1 or outdoors 47 CFR,Part 15,Class B,ICES 003 DRAWING BY: IEC/EN 61010-1:2010, Five-year warranty EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 Metering:ANSI C12.20 accuracy class 0.5(PV production only) PLOT DATE: PROJECT NUMBER: E N P H AS E. To learn more about Enphase offerings,visit enphase.com v E N P H A S E. SHEET NAME: To learn more about Enphase offerings,visit enphase.com SPEC SHEET ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,and other trademarks or service names are the trade- marks of Enphase Energy,Inc.Data subject to change.06-30-2021 REVISION: PAGE NUMBER. ---- SS N05- BLUE RAVEN 1403 N.Research Way Orem,UT 84097 800.377.4480 W W W.BLU ERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION 6.63 .62 DIA WIRING DIAGRAMS HEREIN CONTAINED SHALL NOT BE 16 USED FOR THE BENEFIT OF ANYONE 168 EXCEPT BLUE RAVEN SOLAR NOR 31 DIA FUSIBLE SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE + 8 p p RECIPIENTS ORGANIZATION,EXCEPT SG I I I IN CONNECTION WITH THE SALE AND 13 I I USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION r, A B OF BLUE RAVEN SOLAR LLC. 0 TERMINAL LUGS CERTIFIED AMPERES MAX. WIRE MIN. WIRE TYPE PV INSTALLATION 14.88 1 1 .24 60 #3 AWG -�#14 AWG CU OR AL PROFESSIONAL 376 285 O Scott Gumey #PV-01171 Ml5866 KNOCKOUTS CONDUIT SIZE DIAMETER CONTRACTOR: SYMBOL IN MM FINMM BRS FIELD OPS A,B,C A so 3 zz KNOCKOUTS A,B,C 385�98-6700 KNOCKOUTS B .75 19 29 C 1.00 25 35 D 1.25 32 45 1 .64 1 L 42 L3.76 4.87 96 124 .31 DIA 7 .1 e 7.45 (2 HOLES) 189 NEMA TYPE 3R A,B,C,D KNOCKOUTS ,� ^ q Ly �� (0 KNOCKOUTS INCHES DUAL DIMENSIONS•MILLIMETERS .28 DIA KNOCKOUT A,B,C HORSEPOWER RATINGS 7 KNOCKOUTS CATALOG WIRING AMPERE 240VAC NOTES: NUMBER VOLTAGE RATINGS D1AG. RATING STD. MAX. FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITED OVER CLEANED PHOSPHATIZED STEEL 1 0 3 0 1 0 3 0 DRAWING BY UL LISTED - FILE E-2875 ALL NEUTRALS - INSULATED GROUNDABLE D222NRB 240VAC A 60 3 7.50• 10 15• SUITABLE FOR USE AS SERVICE EQUIPMENT D322NRB 240VAC B 60 3 X 7.50 10 15 SHORT CIRCUIT RATINGS: PLOT DATE: 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES TOP ON NE14A 3R ENCLOSURES HAVE PROVISIONS FOR MAXIMIM 2.50 BOLT-ON HUBS. WHEN MOUNTING THESE SWITCHES, ALLOW 3.00 IN / 76 MM MIN. CLEARANCE BETWEEN ENCLOSURES FOR OPENING OF SIDE HINGED DOOR. GENERAL DUTY SAFETY SWITCHES n SQUARE D COMPANY PROJECT NUMBER )K U5E OUTER SWITCHING POLES VISIBLE BLADE TYPE iI 60 AMPERE •FOR CORNER GROUNDED DELTA SYSTEMS ONLY. ENCLOSURE - NEMA TYPE 3R RAINPROOF DWG- LUGS SUITABLE FOR 60°C OR 75°C CONDUCTORS. 1 863 N0. SHEET NAME: REF DWG *1863 .TUNE 2000 SPEC SHEET REVISION PAGE NUMBER .- ---- SS JB- 1 . 2 EZf SOLAR PHONE; 385-202-4150 EZf SOLAR Specification Sheet making solar simple, WWW,EZSOLARPRODUCTS.COM BLUE RAVEN making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs 1403 N.Research Way Orem,UT 84097 slzE DWG.No. REV A. System Specifications and Ratings ITEM NO. PART NUMBER DESCRIPTION OTY e00.377.44e0 BJ B—1�2 WWW.BLUEMVENSOLAR.COM 1 JB-12 BODY POLYCARBONATE 1 CONFIDENTIAL-THE INFORMATION • Maximum Voltage: 1,000 Volts WITH UV INHIBITORS SCALE:1:2 WEIGHT:1.45 LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE • Maximum Current: 80 Amps POLYCARBONATE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR • Allowable Wire: 14 AWG —6 AWG 2 JB-1.2 LID 1 TORQUE SPECIFICATION: 15'2O LBS IN PART TO OTHERS OUTSIDE WITH UV INHIBITORS RECIPIENTS ORGANIZATION,EXCEPT • Spacing: Please maintain a spacing of at least 1/2"between u UL STANDARD 1741, USE OF THE RESPECTIVE EQUUIPMEIPME ninsulated live parts and fittings for IN CONNECTION WITH THE D conduit, armored cable, and uninsulated live parts of opposite polarity. 3 #10 X 1-1/4"PHILLIPS g CERTIFICATION: NT, WITHOUT THE WRITTEN PERMISSION PAN HEAD SCREW NEMA 3R OF BLUE RAVEN SOLAR LLC. • Enclosure Rating:Type 3R - • Roof Slope Range: 2.5—12:12 4 #8 X 3/4"PHILLIPS WEIGHT:: 1.45 LBS Max Side Wall Fitting Size: 1" PAN HEAD SCREW 6 [—CERTIFIED— • Max Floor Pass-Through Fitting Size: 1" PV INSTALLATION • Ambient Operating Conditions: (-35°C) - (+75°C) PROFESSIONAL Scott Gurney Compliance: #PV-011719-015866 - JB-1.2: UL1741 -Approved wire connectors: must conform to UL1741 CONTRACTOR: • B System Marking: Interek Symbol and File#5019942 �'.- 38 FIELD OPS �� 385-498-6700 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion / between components, components that are found to be affected are to be replaced immediately. Table 1;Typical Wire Size,Torque Loads and Ratings 1 Conductor 2 Conductor Torque o Type IVM Inch Lbs Voltage Current ABB Z56terminal block 10.24 awg 16.24 awg Sol/Str 0.5-0.7 6.24.85 600V 30arnp ABB ZS10 terminal block 6.24 awg 12.20 aw¢ Sol/Str 1.0.1.6 8.85-14,16 600V 40 amp O- ABB Z516 terminal bock 4.24 awg 10.20 awg Sol/Str 1.6.2.4 14.6.21.24 600V 60 amp O f 279.66mm] L276.30mm L� r ABB 1106/8 terminal block 8.22 awg Sol/Sty .08-1 8,85 600V 50 amp 1 1.01 in 10.8811 Ideal452 Red WING-NUTWire 9-18awg Sol/Str Self Torque Self Torque 600V Connector SOLAR Ideal 451 Yellow WI NG-NUT 10-18 awg Sol/Str Self Torque Self Torque 600V WireConnector 1 Ideal,In-Sure Push-In 10-14awg Sol/Str Self Torque SellTorque 600V 2-1.2 I Connector Part I139 WAGO,2204-1201 10-20 awg 16-24awg Sol/Str Self Torque Self Torque 60UV 30amp , WAGo,221-612 10-20 awg 10-24awg Sol/Str Self Torque Self Torque 600V 30amp DottieDRC75 6-12awg Sol/Str Snap-In Snap4n r ESP NG 53 4-6 a'° Sol/Str 45 2000V 1 10-14 awg SallStr 35 _- ESP NG-717 4-6aw Sol/Sty 45 2000V + _ / DRAWING BY: 10-14 awg Sollstr 35 Brumall43,3 4-6 awg SoUstr 45 2000V ` 10-14 awg Sol/Sty 35 _ 153.06mrn 72.53mm 7.21 in 2.Min PLOT DATE: Table 2:PAnlmum wire-bending spate for conductors ftmah a wall opposite terminals in mm(Ihs) .265,18mm! Wlresb*,AWG 4r VAMS per tennbw(Ode) - 10,441n --'- PROJECT NUMBER: 2 3 A or Mara kertlll (nlln2) mm Ilndtl mm cinch) am (atoll) mm (frldd 14-10 (2.1-5-3) Not specified - SHEET NAM 8 (8,4) 38.1 [1.1/21 6 (13.3) 5o.s cal SPEC SHEET REVISION. PAGE NUMBER: EZtSOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM PROPRIETARY AND CONFIDENTIAL,THE INFORMATION CONTAINED INTHIS DRAWING ISTHESOLE PROPERTYOF EZSOLAR. ———— SS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRffTEN PERMISSION OF EZ SOLAR IS PROHIBITED. SLUF RAVEN Rigid Nonmetallic Conduiti Boxes s A �� corion° 1403 N.Research Way Orem,UT 84097 Molded Nonmetallic Junction Boxes Except where noted �ED 8°0.377.4480 by E42728 VIEW SHOWN LESS WWW.BLUERAVENSOLAR.COM 6P Rated COVER FOR CLARITY 3 70- CONFIDENTIAL-THE INFORMATION E 9 4] ,� 2 O HEREIN CONTAINED SHALL NOT BE [5, I ] USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR It's another first from Carlon®-the first nonmetallic SHALL IT BE DISCLOSED IN WHOLE OR I IN PART TO OTHERS OUTSIDE junction boxes UL Listed with a NEMA 6P rating per RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND Section 314.29,Exception of the National Electrical Code. USE OF THE RESPECTIVE EQUIPMENT, Manufactured from PVC or PPO thermoplastic molding 3.70 `� WITHOUT THE WRITTEN PERMISSION compound and featuring foam-in-place gasketed lids [9 4] 2 Ti50 OF BLUE RAVEN SOLAR LLC. _„_ [ 12 attached with stainless steel screws,these rugged [5I4] [ 2, ] , andphysical �NABCEP enclosures offer all the corrosion resistance _- properties you need for direct burial applications. CERTIFIED Type 6P enclosures are intended for indoor or outdoor PV INSTALLATION use,primarily to provide a degree of protection against PROFESSIONAL contact with enclosed equipment,falling dirt,hose- Scott Gumey directed water,entry of water during prolonged jg #PV-011719-015866 submersion at a limited depth,and external ice - CONTRACTOR: formation. BRS FIELD OPS 385-498-6700 Tc W •All Carlon Junction Boxes t __ are UL Listed and maintain j F 0 0_ o [- A n T - a minimum of a NEMA Type *�— 4/4x Rating. O I o i ! •Parts numbers with an j H o e o o ! I C asterisk(*)are UL Listed and SIZE A B C I ! maintain a NEMA Type 6P I I y{1e E989NNJ 2.00 4.63 5.13 Ratingand Type 4/4X Rating. E969N.JB 150,07 11I1,fi7 f 170,2) 1 d 9 E989NNJ-CAR CO O i i E989NNJCL 1 _ TB E989NNJL O O O -- X E9B9NNR N. 5.00 5 50 r E9B9NNR-CAR 1152.41 1127,01 1139,11 1 14X4Xfi7 15 j Size in SW. Material Std. [3,811 Inches ctn. Min Min. Min. Min. Ta Tc Thermo- CO. Part No. H x W x D Qty. AT AB B c Typical PVC plastic Wt.(Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 311116 35/8 N/A 2 .160 .155 X 3 E987N-CAR* 4x4x4 5 311/16 3112 N/A 4 .160 .155 X 4 NOTES SECTION A-A I MATERIAL: PVC tE989NNR-CAR* 4x4x6 4 311116 1 33/8 N/A 6 .160 .200 X 5 2 NEMA TYPES: 4/4X, 6P C SCALE 0.500 E989PPJ-CAR* 5 x 5 x 2 4 411/16 1 41/2 N/A z .110 .150 X 3 DRAWING BY: E987R-CAR* 6 x 6 x 4 2 6 55/8 WA 4 .190 .190 X 3 E989RRR-UPC* 6 x 6 x 6 8 55/8 53/8 N/A 6 .160 .150 X 14 GEM9tAL NOTES 1 E989N- 8x8x4 1 8 8 WA 4 .185 .190 X 2 I. ALL DIMENSIONS ARE FOR REFERENCE ONLY m.+nb.com PLOT DATE: CAR E98955XUPC 8x8x7 z 721132 75/16 NIA 7 .160 .150 X 6 2 DIMENSIONS IN BRACKETS [ ] MET A IN METRIC UNITS DESCRIPTION MOLDED NON-METALLIC ENCLOSURE E989UUN 12xl2x4 3 115/8 111/2 111/8 4 .160 .150 X 12 RE111SIDA6 E989R-UPC 12 x 12 x 6 2 1115/16 117/8 117/16 6 .265 .185 X 10 F SEE ERN 2016195 PROJECT NUMBER' FOR APPROVAL SIGNATURES ORIGINAL PROJECT NO / I ERN NO 1 I SHEET NO I REV. NO I DRAWING NO: PROJECTS NO: 5AM000006 / [ I 2 OF 2 F WSD-AC01977 THIS DRAWING IS INTENDED FOR DESCRIPTIVE PURPOSES ONLY. AND THE RIGHT IS RESERVED TO DEVIATE FROM ANY OF THE DETAILS SHOWN HEREON, SHEET NAME- 180 www.carion.com Copyright Thomas 6 Betts - Propr ie for y, AI I Rights Reserved SPEC SHEET Gross Automation(877)268-3700-www.carionsales.com-sales@grossautomation.com REVISION' PAGE NUMBER, ---- SS BLUE RAVEN SOLAR Solar"Stay Connected"with Power I I Heyco'-Tite Liquid Tight Cordops for Enphase_Q_Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Ultimate in Liquid Tight Strain Relief Protection PRDDUCTI GLAND PART NO. DESCRIPTION PART DIMENSIONS •Two new cordgrips now accommodate CONFIGURATION ®/� A e c D E the Enphase D Cable-M3231 GCZ conductor: or Clearance Maz.O.A.�Thread Wrenching Nut (1/2 NPT)and M3234GDA SM type Size No. Black e1ASr HoleDla. Lengtll Length ThklmewFhdSin (3/4"NPT). • I mm. In. imm.i In.i•mm., in.1mm� in.Jmm.l In.lmm. .The 1/2-version provides liquid tight Oval Gland entry for one Enphase 0 Cable- D Gable I6,1 x 9,7I 1 IM3231OCZ I LTCG 112 6.1x9.7MM IS/ I.875I22,2I 1.70 43,2I.61115,51.21 15,3 I .98I24,9 .24 x.38-(6,1 x 9,7 mm). Break-Thru Skinned Over Gland •The 3/4-version provides liquid tight o Catiftl Plus6,1X9.71 jr�onA•sMSMCG d2$t'� "hM011L*2.0gs0,e •62,t512sl r i 301�,o entry for up to two Enphase 0 Cables- Ground, I 3MMI I I I I 11 I I 1 .24 x.38"(6,1 x 9.7 mm)and an Metal Locknuts INCLUDED. B additional.130"(3,3 mm)dia,hole for c a 18 solid grounding cable. - o A •The 314"version utilizes our skinned- over technology so any unused holes will retain a liquid tight seat. •Rated for use with DG Cable. SUGGESTED CLEARANCE HOLE SEALING NUT= INTEGRAL FOR NONTHREAOEO MOUNTING SEALING RING Material Nylon 6/6 with TPE Sealing Gland Certifications ® Listed under Underwriters'Laboratories File E504900 Sp CSA Cert'died by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40°F(-40°C)to 239°F(115"C) Dynamic-4°F(-20'C)to 212'F(100°C) IP Rating IP 68 ALL NEW Heyco'Helios'UVX Clip-Blind Mount I'll, s PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL •The jersey pine tree mounting style RANGE HOLE DIA. HEIGHT installs easily with superior holding Minimum Maximum 1-2 Wires A C power. in mm. in. i mm. in. mm. M.I mm. .UVX nylon protects from corrosion due 1-2 Wires to outdoor exposure. 028 1 0,7 .250 6,4 .23(5,8mm) .32(B4Omm)!. li8820 1He8osuVXcap10oPads 260 6.6 .9s�24,4 •Installs into.260-(6,6 mm)mounting i each cable S6560 Hellos UVX Clip Bulkhole. •Holds up to 2 cables between .230- ' .0, .315-(5,8-8,0 mm)each. c •Cables install with fingertip pressure. V A •Molded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4'F(-20'C)to 185'F(85"C) DRAWING NUMBER: /� 1-800-526-4182.732-286-1800(NJ)•FAX:732-244-8843•www.heyco.com BLUE RAVEN Non■• U N I SFM INFINITY on GETTER SOLAR STARTS HERE SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PARTINAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer i attachments than rail systems. TRIMRAIL Structural front trim provides aesthetic and aligns modules. 2 INSTALLS PER DAY Make two installs per day your new standard.SFM INFINITY has fewer 1 r \ , l TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. roof attachments,one tool installation,and pre-assembled components to get you off the roof 40%faster. I �{ TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. SFM INFINITY 15 Attachments I Le MODULE CLIPS Secure modules to TRIMRAIL. ff oil M MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east west bonding. ATTACHED SPLICE also available. with integrated front trim,trim end caps,dark components,and recessed hardware. SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density With fewer SKUs and compact components,SFM INFINITY is easierto without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES stock,easier to transport,and easier to lift to the roof,Plus,make more attachments required by rail. PARTNAME DESCRIPTION efficient use of your vehicle fleet. TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules O N/S BONDING CLAMP Electrically bonds rows of modules P0804 • 11* SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH I ARRAY INSTALLATION AND SERVICE. DRAWING NUMBER: SS ■. i SUN � BLUE RAVEN SYSTEM BONDING & GROUNDING NNO I FRAME TM INSTALLATION GUIDE- 'I- P A G E MM ,__S FMMICRORAII _____ i _ _ ____________________________ ------------------------------- 0 0 E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. i e Star Washer is WEEBLUG Single Use Only Single Use Only I Alternate method N-S BONDING PATH: TERMINALTORQUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMINALTORQUE, TERMINALTORQUE, bonding pins. (refer also to alternate method) 4-6 AWG: 35in-lbs Install Conductor and Install Conductor and 8 AWG:25 in-lbs torque to the following: torque to the following: 10-14 AWG: 20 in-lbs 4-14 AWG: 35in-lbs 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO =� Ilsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7) 10-32 mounting hardware / "1 4 mountinghardware 1/4" mounting hardware • Torque = 5 ft-lb a Torque = 75 in-lb 0 Torque = 10 ft-lb Alternate method • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded a AWG 6-14-Solid or Stranded TRIMRAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUMINUM CONTACTTO PREVENT CORROSION Trimrail to module bonding is accomplished with System bonding is accomplished through moduLes.System grounding accomplished by attaching bonding clamp with integral bonding pin and bonding T bolt. (refer als® to alternate method) DRAWING NUMBER: a ground Lug to any module at a Location on the module specified by the module manufacturer. SS ■ � � SUN BLUE RAVEN , Z0 NEff ; SF MFRAME , ■■ MICRORAIL TM INSTALLATION GUIDE PAGE ____________________________________________________ SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures SUNFRAME MICRORAIL(SFM) Installation Guide.SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTm components shall B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules.Class A, B & C system level fire Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation -� Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required UL2703 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF / 5400 Pa b) Upward Pressure - 50 PSF /2400 Pa c) Down-Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF/ 8000 Pa b) Upward Pressure - 75 PSF/ 3500 Pa c) Down-Slope Load - 32.4 PSF/ 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less DRAWING NUMBER: SS ■ SUN TESTED / CERTIFIED MODULE LIST s �� BLUE RAVEN JC-1LtiR ■ow , SFM FRAME NN � MICRORAIL TM INSTALLATION GLIDE ; PAGE ------------_-------------------------_------------------------------------------------------------------------ Manufacture Module ModeL/Series Manufacture Module Model/Series Manufacture Module Model/Series ALeo P-Series Eco Solargy Orion 1000 &ApoLLo 1000 LGxxxN2T-A4 ET Solar ET-M672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ DNA-120-(B F/M F)26 - Q1 C/Q1 K/S1C/S2W)-A5 Aptos Freedom Forever FF-MP-BBB-370 I DNA-144-(BF/MF)26 LGxxxN2T-B5 FreeVolt Mono PERC -. LGxxxN1K-66 CHSM6612P,CHSM6612P/HV,CHSM6612M, GCL GCL-P6 &GCL-M6 Series LGxxx(A1C/M1C/M1K/N1C/N1K/Q1C/QiK/ Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), HansoL TD-AN3,TD-AN4, LG ELectronics QAC/QAK)-A6 CHSM72M-HC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W)-E6 AXN6M610T,AXN6P610T 36M,60M,60P,72M &72P Series, LGxxx(N1C/NiK/N2W/S1C/S2W)-G4 Auxin AXN6M612T&AXN6P612T Heliene 144HC M6 Monofacial/Bifacial Series, LGxxxN2T-J5 AXlblackpremium 60(35mm), 144HC M10 SL BifaciaL LGxxx(N1K/N1W/N2T/N2W)-L5 AXlpower 60(35mm), HT Solar HT60-156(M)(NDV)(-F), LGxxx(NiC/Q1C/QiK)-N5 Axitec AXlpower 72 (40mm), HT 72-156(M/P) LGxxx(N1C/N1K/N2W/Q1C/Q1K)-V5 AXlpremium 60(35mm), KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM Hyundai AXlpremium 72 (40mm). i HiA-SxxxHG LR4-72(HIH/HPH)-xxxM BVM6610, ITEK iT,iT-HE &iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30mm) Boviet BVM6612 ' LR6-60(BK)(PE)(HPB)(HPH)-xxxM(35mm) Japan Solar JPS-60 &JPS-72 Series BYD P6K& MHK-36 Series LONG LR6-60(BK)(PE)(PB)(PH)-xxxM(40mm) JAP6 60-xxx,JAM 6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM(30mm) CSl(H/K/U/`�-MS xxx,JAP6(k)-72-xxx/4B B,JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM C53(K/L/U),CS3K-MB-AG,C53K-(MS/P) JAP6(k)-60-xxx/4BB,JAP60SYY-xxx/ZZ, (35mm) Canadian Solar CS3N-MS,CS3U-MB-AG,CS3U-(MS/P),CS3W JASolar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM(40mm) CS5A-M,C56(K/U),CS6K-(M/P),CS6K-MS JAM6(k)-60-xxx/ZZ,JAM60SYY-xxx/ZZ. Mission Solar Energy MSE Series C56P-(M/P),C56U-(M/P),C56V-M,CS6X-P i.YY:01,02,03,09,10 CentrosoLar America C-Series & E-Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi MJE & MLE Series CT2xxMxx-01,CT2xxPxx-01, JKM &JKMS Series Neo Solar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, CTxxxMxx-04,CTxxxHC11-04 Jinko EagLe JKMxxxM JKMxxxM-72HL-V Dehui DH-60M - - Kyocera KU Series • Unless otherwise noted,all modules listed above include aLL wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible moduLe's model ID • SLashes "/" between one or more items indicates that either of those items may be the one that is present in a moduLe's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of Less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information DRAWING NUMBER: SS SUN BLUE RAVEN TESTED / CERTIFIED MODULE LIST i23 MEN , S-F MFRAME , ■� MICRORAILMT INSTALLATION GUIDE , PAGE--------------------------------------------- --------------------------------------- --------- Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series jTwinPeak Series Suniva MV Series&Optimus Series EVPVxxx(H/K/PK), A-Series A400-BLK,SPR-MAX3 XXX-R, VBHNxxxSA15 &SA16, TwinPeak 2 Series SunPower VBHNxxxSA17&SA18, TwinPeak 2 BLK2 Series X Series,E-Series&P-Series REC Solar(cont.) Panasonic VBHNxxxSA17(E/G) &SA18E, TwinPeak 2S(M)72(XV) Suntech STP,STPXXXS-B60/Wnhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38mm) TP572,TP596,TP654,TP660, Talesun TP4(Black) VBHNxxxZA01,VBHNxxxZA02, _ TP672,Hipor M,Smart VBHNxxxZA03,VBHNxxxZA04 Renesota f Vitrus2 Series & 156 Series SC,SC 8,SC Bl,SC 62 Testa Peimar SGxxxM(FB/BF) Risen RSM72-6(MDG) (M),RSM60-6 i TxxxH,TxxxS Phono Solar PS-60,PS-72 SEG-xxx-BMD-HV PA05,PD05,DD05,DE06,DD06,PE06, - SEG Solar iSEC-xxx-BMD-TB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Prism Solar P72 Series Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy SN72 &SN60 Series(40mm) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim SEG-6 &SRP-6 Series i UP-MxxxP(-B), Upsolar QPEAK DUO BLK-G6+ Sharp NU-SA&NU-SC Series UP-MxxxM(-B) QPEAK DUO BLK-G6+/TS �SLA, SLG,BC Series &SlLxxx(BL/NL,/NT/HL/ D7MxxxH7A,D7(M/K)xxXHBA QPEAK DUO(BLK)-G8(+) SiLfab ML/BK/NX/NU/HC) United Renewable Energy FAKxxx(CBG/E8G),FAMxxxE7G-BB QCeLLs QPEAK DUO L-G8.3/BFF �_Solarever USA } SE-166'83-xxxM-120N (URE) FAMxxxE8G(-BB) QPEAK DUO(BLK) ML-G9(+) PowerXT-xxxR-(AC/PD/BD) FBMxxxMFG-BB QPEAK DUO XL-G9/0.2/0.3 Solaria PowerXT-xxxC-PD Eldora, QPEAK DUO(BLK)ML-G10(+) PowerXT-xxxR-PM(AC) Vikram SoLivo, QPEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Somera ' Sunmodule Protect, QPEAK DUO BLK ML-G10+/t SoLarWorLd Sunmodule Plus Waaree AC&Adiya Series _ Alpha(72)(Black)(Pure) - SS-M-360 to 390 Series, Winaico WST&WSP Series RECxxxAA PURE-R Yin Li YGE &YLM Series SS-M-390 to 400 Series, 9 RECxxxNP3 BLack SonaLi SS-M-440 to 460 Series, ZN Shine ZXM6-72, ZXM6-NH144-166_2094 N-Peak(BLack) REC Solar SS-M-430 to 460 BiFaciat Series, N-Peak 2 (BLack) SS 230-265 PEAK Energy Series �Sun�Eison F-Series,R-Series &FLEX FXS Series PEAK Energy BLK2 Series PEAK Energy 72 Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information S BLUE RAVEN Intertek AUTHORIZATION TO MARK Intertek AUTHORIZATION TO MARK Total Quality.Assured Total Quality.Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee models) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable_ The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification marks) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE Address: Address: Albuquerque, NM 87102 Address. Albuquerque, NM 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc_, Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CAS Control Number: 5003705 Authorized by: Lv�''' �� Control Number: 5014989 Authorized by: for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager C Taus C us { o Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number- This document supersedes all previous Authorizations to Mark for the noted Report Number. TIR,s AUltxmrah,X,t:i Mark xS ke 7K,exdi,twa us0 of IM)w1i's Cl,on'W.I.is fua+-�ra1 py'fi,.a+'n In Ih0 C{iraf Galiv.AgntK.I lent Gnl.nhnn IrtnlOk, Il,Is chpnt lnlMak's r po-wt.hty and Labbly arri Ths AI Irlt,lDan to WWI,d fat-4 o,LLvrn ute of IncoUks C1Io1Y and 11,pavdoa V.+r%"W 10"coili tabon agroamone Out'Mrtn IMmtai AM Ito 0-M 1ntedai't resµni,An-t and IJb-dy arc t:m1aQ If,Ih.?rAttt4 arAi(xiI'.+dDOrrF a1 Ih0 agro0n'aTril Inter lak at.Syr.�p;IX)I�tINI[y to any rally,dM,Or than to I"Client in ti�A'A"Jan'?7 w:7 Ih@ a9raemplY.1CK any fcF.s,0xpnhc!d dan,a9a[r1.' ior+Gd ruetod to tf0 taro.and cor 1t•Orq of IN AgMarnnM Intomw aulu ps no tao-ty to any party.04,a,than to Iho CIM1 I,&Mao&,"+rllh"agr*# Wd for ant 10"axpnnae or damaj0 o-V DLC,od t'Y 140 IjSe 01 th,5 Aulh vi7an:ni Its Mark C,ly the CW-1 is aulhesn20d to poma l' ,7YMj.^,r d,S1nh{,GCrt o!Snit AulhoeitXo r,IO Malk and INY,ordy e,,1S OnhfOty lkq of IMAelB+$COA,fK,;ilKin TWk R Of It,n uta 01 Ilya AIIt117t12.tnan to RA,Irk Only tha Giaril n cif"A Yd t0110r^S oIMM rr fu(V wt N tht Auftq lyalKm to M,In And a1e.„br'aY,n dS O Of I!u OIL=.�rt1i 0 'diXJ ce rM.e It !"_o'✓,#cd to L,0,fNIPIWI�I.m wl in the agre;'K�l and,:1 Ih y Aulhg lnlKM.W mail,jkoy funtof uw of the I•norlok n ~.!p:C,I.I m1k,or yy.@rl,6aflgn!{d Ihr 10 1W fnalpf�Y ;xo-iiN�Cx f.+�^.vpp m„,I t_UKibd to Cw ca,dMyN 1.0 o,a m 7.arpo+,+on1 al+d In OH AutltiYlLthon So t tJrk A1ry tufVwt u->0�Y thn In10r;.k Won't,1tv 1h0 bgly O'241v[,rI150mt'I',1 df lMi L?SIIM n'alOr.il,prGd,sJ p.•.pr.,c0 r.utt f'4I C�a{K:fava><i,n w,uIIR tit h'dursV_IniL11 Faclwy Avkssn+arts aFd Folrin•up Si.,rv+lwc a,d 1tv II,B Iwryx N ass>_+nitj ar;IplWl�aro usafe of the Caruf._;a1wn Work In a�rclanca unit)Iho fiotte appo-0 in"bfV2 Dy InlufW6 Ir,tial Factory Aaat3ernvSt a-w FOIKrw w Sel.+cas and fa N=pur;.tya of�sw+Inp appopwla,.,sa�td ca Ir d Cerofiwuan Turk in acctxdarrx•,vrlh Il+d aprean+er.`,they arc rN.lot the p T-3tet a prcG+r'm pualIty control and do rat r'levc'ho Oienl❑'inelr In th,s respect, a;o0O 'YL lhey are riot to the purpo� %of pro0.1c-hon tf Dmfy CC"and do nol tela.e the CI ell of I!mrr Wlgnhoa In 1I rea0erl Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat- Mounting Systems,Mounting Devices, Clam pinglRetention Devices, and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed Standard(s): _1+R:24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[GSA TIL No.A-40:20201 PV Module and Panel Racking Mounting System and Accessories (CSA TIL No.A-40:20201 Product: Photovoltaic Mounting System, Sun Frame N%crorail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Micrerail Installation Guide, PUB2023MAYI O Brand Name: Unirac brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued: 17-May-2023 ED 16 3 15 11-Jul-20221 Nk-1dalc*y ED 1(315 il-,V-2R22}Mar),;,s'a,y DRAWING NUMBER: SS Ne--- BLUE RAVEN Intertek AUTHORIZATION TO MARK tn to r to k AUTHORIZATION TO MARK Total Quality.Assured. Total Quallty.Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Gerfification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the Conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. This document is the property of Intertek Testing Services and is not transferable_ The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mari, Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE Address: Address: Albuquerque, NM 87102 Address: Albuquerque, NM 87102 Country: USA Country: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc.. Lake Forest, GA Report Issuing Office: Intertek ek Testing Services NA, Inc.. Lake Forest, CA � t�/ Control Number: 5019851 Authorized by: \g,,,Y �x�y Control Number: 5021866 Authorized by: ` for L Matthew Snyder, Certification Manager for L_ Matthew Snyder, Certification Manager ge COTUS C <rr>10 US Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number, This A.III—Iaion 10 f ta.•L:,s for tha oxrs--,.usa of p-4nd pirsuarr?a the Cerelrral,r .19! I t q—an IrnaroeY.and it,Clrnn[ hablily 810 Tf-s AuC+onzntton to 11N•is for rw of Irfc•te/:D Cl'w-and i►ptOvrOsd purwam to 7ro ow hr.at o agreerrm=txita,uan tntcrtrs,am-,A QMl Irtc.IM's rpspmyfisrty uM taOrdy ere limund 0 inn teenru anC cgndr. r-of Iho aarorrrraet Inlarink a.—runs no Irnh,I1y m any party,atha tnan W thrr e11en1 `1 11 rdnoo In thn a5rnnrtv .irx arty IO•.s.expel O!r7lnr.nr?iX1*SiV*,J IV,16d to Ins-Arms ar4 a W.nep,,a Chn asrser o Inle k a .0 no LabAty to any party_otnur Inv,to Ino Cinnt.r xcordamt W--1 tns a9rowront,by art,loss„expense Or denygs O0C*V0M W trio LAO W this Aulhar ratan to Atah Only Crrr GdY tc 141JN11:ed Vi tlnnTtt coprinlj er"r-bahor of thK/4rineR:alKM1 10 Ata<k aN tna+a<,ly:n n M:Ietr Use,OI lnrertnk D Ga�efrrtrlltNr rtylrk If trj Ih,n use or M,ALf',On rjb fir£fXily 1hn G�nrn,s a1lhLraad?n perms wr.yr"✓•.or d15'nbuarel of Crs AuE"7.ahon eo Male.and ttx:n"In It;enerary us.of Intti•Iek'6�rxhfrcdl>;�n rrCtrk o tY t rnslnrlmd ro the rsxdr..cns Ia4 put in the a ty in.C,and.in 7nhoro hora�n,Hopi in M.ak Any iurtnar vyrt rt inn Irvnittt name to the sale s ad,rr.L;.r,nsnr�of the leahrit rru3lar:Ar prOdrn7 Or sic nct�rrwsl rffW�:Wd to W.eLrrWa-OAS lard= l t"aVeferrrnl.>ub In thD Autl+on�lran rn�tnn Ivry T.rN�cr uin o1 the YnpM!k nx•rre.7r^^_nn saki a aCvmt'umtnl rV Cp In:cled rru5hinal-prvducl cr wrna rrx+gt. fr6t Do appfc.ed:n wtien,9 by Inldrlek-Initial Facer),Assess+nonts and FeIMx-to Saroms are for the pulr,Dso Of assuf-fq apprcpnala L6age df Coe Cerbficaw,l Turk m aceordarrca vnth the rest be avvowd M*rr^CY IrtiMek In+,af Fa:lary ggse5lmorXt Ytd FOIKrw up SMr✓.ei a•o try tiro puI,C-5 K i s . U appt tioct usaac cA the Grrc!�rahon rr�•k m acrxrdar�.t wr�i d,e 1�rer.nonl,7iey arc rvl fcx the purpo.cs OI IxocW�cr,r�ualrty cmfrci arrd eo rql refr:e iho GierR of tha'obi ga:ons n this rczFed rproer ew,tray are rWt fY M Purile'sez of p co+"- 9usth cor&N a^y bo rWt rohdre We Client d roar op113- �n the re•.ped Intertek Testing Services NA Inc. Intertek Testing Services NA Inc, 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 o¢847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping�Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, CiampinglRetentlon Devices,and Ground Lugs for Use with Flat- 5tandard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed,1+R:24Mar2021] Standard(s): Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar20211 PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories[GSA TIL No-A-40:20201 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounling System, Sun Frame Microrail Installation Guide, PUB2023NIAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM ATM Issued: 17-May-2023 Page 4 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 3 of 4 ATM for Report 102393982LAX-002 g ER 1E ,=.i,_,rF_yp12pMa�>,isgpry DRAWING NUMBER: E!J 15 3 15 r1-Jul-2Q:."I tdarWelwy SS '* O� �t�rtek �ntertek 3LUE RAVEN Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) Total Quality.Assured. Total Quality.Assured. 1.0 Reference and Address 1.0 Reference and Address Report Number 102393982LAX-002 Original 11-A r-2016 Revised: 5-Oct-2022 Report Number 102393982LAX-002 Orioinal 11-A r-2016 Revised: 5-Oct-2022 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use Email Standard(s) with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:2020] Applicant Unirac, Inc Manufacturer 2 Address 1411 Broadway Blvd NE Address Albuquerque, NM 87102 Country USA Country Contact Klaus Nicolaedis Contact Todd Ganshaw Phone 505-462-2190 Phone 505-843-1418 FAX NA FAX Email klaus.nicolaedis@unirac.com Email toddg@unirac.com ::: Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email 7ail :] Manufacturer 5 Address Country Contact Phone FAX Page 1 of 138 Page 2 of 138 and This report is for the exclusive use of truenek's Client and 4 provided pursuant to the agreement between Intertek and its Client Intenek s responsbx Sy and This report is for the exclusive use of wertws Client and s pfovv ed pursuant t the no t agreement any Intertek other tnanand its o Client CI���ases�� nd I:abrkty are IimAed to the terms and oondtions of the agreement tY•Ry y party. I are lirtttod to the tenths and consrtions of the aby the fit f Y pant. Intenek assumes no Iw t0 an other than to the Client in accordance with the wt;." and apeemerd,for any loss expense or damage Occasioned by the use CA this report On.y the Client is authorw[d to perms copying or distribution of this report and aryeenhent,for any loss.expense a damage occas+oned trf Vie use o!this report Only the Client is authorizedeofthe to perms copy" r duct Or se i this repot then only in its entirety Any use of the Mtenek name or one a its marks for the sale a advenrsement of the tested matenal.prod,.zt or service must first be then only m its entirety.Any use of the lnterWk name or one Of its marks f the sate a advertisement of the tested matrnai, podgy; S imply � 1 DRAWING NUMBER: approved in writing bf Imenek The obtsenrabons and test results in this report are rehevant only to me sample tested This repot tq itself does not imply that the approved in*filing by Intenek The observanons and test results in this re n are relevant one to the sample tested This report tier vt /� /► material.product,or sere ce is or has ever been under an Intenek cerlft3t On progfam material_p(Oduet 4.or service Or tuts ever oeen under an Intertek certification Program SS Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-Apr-2016 Report No. 102393982L AX-002 Page 4 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 Unirac, Inc Revised: 5-Oct-2022 BLUE RAVEN Unirac, Inc 2.0 Product Description 2.0 Product Description Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Models Unirac SFM Brand name Unirac Model Similarity NA The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System.This system is designed to provide bonding and grounding to Fuse Rating: 30A photovoltaic modules.The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report.There are no rails Module Orientation: Portrait landscape within this product,whereas the 3"Micro Rail, Floating Splice, and 9"Attached Splice Maximum Module Size: electrically bond the modules together forming the path to ground. UL2703 Design Load Ratting:ang:8 ft 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket.The bonding pin of the Micro Rail when bolted and torqued, penetrate Increased size ML test: 2 the anodized coating of the photovoltaic module frame(at bottom flange)to contact the metal, Maximum Module Size: ft creating a bonded connection from module to module. UL2703 Design Load Rating: : 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG355S2W-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating:46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope revision in effect in the jurisdiction in which the project resides.Any local electrical codes must LG395N2W-A5, be adhered in addition to the national electrical codes.The Grounding Lug is secured to the LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. photovoltaic module, torqued in accordance with the installation manual provided in this Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same Certifications, & Increase SFM System UL2703 Module Size: engage cable. Maximum Module Size:27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size:21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roofs surface See section 7.0 illustractions#1, 1 a and 1 b for a complete list of PV modules evaluated with these racking systems Other Ratings NA DRAWING NUM BER: ED 16.3 15(1-Jul-2022)Mandatory ED 16 3 15(1-Jul-2022)Mandatory CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Pen-nit Center:360-403-3551 BUILDING PERMIT 8109 CROWN RIDGE BLVD Permit#:4175 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00904500000600 DATE OF ISSUANCE. Scope of Work: Re-Roof Valuation: 9150.00 OWNER APPLICANT CONTRACTOR VANDEBOGART PAUL L&DIANE M S&S Roofing S&S Roofing, LLC 8109 CROWN RIDGE BLVD 104 S West Ave 104 S West Ave ARLINGTON,WA 98223-4020 Arlington,WA 98223 Arlington,WA 98223 3603869903 3603869903 LIC:SSROOSR918MM EXP:08/03/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Re-Roof CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such constriction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance, regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Govemor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE.LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSAHON INSURANCE AND RCW 19.27. THIS APPLICATION 1S NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC l t0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington trust be reported on your sales tax return form and coded City of Arlington#3101. I V1'ow I U h f a 10/7/2021 ugnature Print Name Date Released By Date CONDITIONS Approved permit shall be onsite during construction.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO RE DONE ON PRiVATF. PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/06/2021 Re-Roof Residential $75.00 10/06/2021 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i -� RE-ROOF PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360) 403-3551 Type of permit: (check one) (d) Residential ( ) Commercial Valuation:9,150.00 8109 Crown Ridge Blvd. Arlignton, WA 98223 Project Address: Parcel ID#: Owner: Mike Lamb & Diane Vandebogart 8109 Crown Ridge Blvd Arlington WA 98223 Address: City: State: Zip Code: Phone Number: 360-386-9903 Email:jennifersandsroofing@ hotmail.com Applicant:S&S Roofing LLC Address: 104 S. West Ave City:Arlington State: WA Zip Code.98223 360-386-9903 jennifersandsroofing@ hotmail.com Phone Number: Email: S&S Roofing LLC Contractor: 104 S. West Ave Arlington WA 98223 Address: City: State: Zip Code: 360-386-9903 jennifesandsroofing@ hotmail.com Phone Number: Email S S ROOS R918M M 8/3/23 Contractor's License Number. Expiration: Type of Roofing Material: Owens Corning Oakridge Number of Existing Layers: 1 Class of Roofing: A ✓❑ B ❑ C ❑ Replacing existing sheathing: Yes ❑ No Roof tear off: Fj] Application over existing material: ❑ The following is required for NON-Residential Buildings: • Existing roof structure and material: • Two copies of the installation specifications and U.L.listed roof assembly • Occupancy of Building. Office Retail Church Restaurant School I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. f " c"t 10/05/2021 Applicants Signature Date Jennifer Turrone Print Applicants Name R!?ce111e� FOR STAFF USE ONLY OCT o 5 2021 ad- Permit# Acco t y Amount Received Receipt# Date Received i Permit#: 4175 Permit Date: 10/06/21 Permit Type: RESIDENTIAL RE-ROOF Project Name: Vandebogart Applicant Name: S&S Roofing Applicant Address: 104 S West Ave Applicant, City, State, Zip: Arlington,WA 98223 Contact: Jennifer Turrone Phone: 3603869903 Email: danasandsroofing@hotmail.com;jennifersandsroofing@hotmail.com Scope of Work: Re-Roof Valuation: 9150.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 04/04/2022 Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 8109 CROWN RIDGE VANDEBOGART 100 SINGLE 00904500000600 BLVD PAUL L&DIANE FAMILY M RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# 104 S WEST CONSTRUCTION COA Business S&S ROOFING LLC 3603869903 602 934 849 AVE CONTRACTOR License 104 S WEST CONSTRUCTION Labor& SSROOSR918MM S&S ROOFING LLC 3603869903 AVE CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 11/19/2021 R00.1 RE-ROOF AM or PM 11/22/2021 11/22/2021 BUILDING Approved FINAL Fees Fee Description Notes Amount Re-Roof Residential Residential $75.00 Processing/Technology $25.00 Credit Card Service $3.00 Total $103.00 Attached Letters Date Letter Description 10/06/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/06/2021 Sheri Dunlap 88956240 $100.00 10/06/2021 Ameresia Lawlis $3.00 Outstanding Balance $0.00 Uploaded Files Date File Name 10/07/2021 9847135-4175 Signed Permit.pdf 10/06/2021 9838200-10-5 Vandebogart Reroofpdf